1 75 Inline /-, 5/- and 5/ directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves G /, / NPT, G /, / NPT For single and double operated actuators Crossover-free switching, switch-over function guaranteed even with small cross section Rest position in the event of power failure provided by mechanical return spring (monostable) design Add-on manual override Suitable for outdoor installation if equipped with corresponding solenoid Minimal electrical power consumption therefore many protection classes possible, e.g. EEx i The solenoid valves are applicable in the protection class EEx me, EEx md, EEx m, EEx ia for zones, (gases),, (dusts), ATEX cat. II GD Additional protection class (FM, CSA): XP, NI, AEx ia Technical data Medium: Filtered, non-lubricate and dried compressed air, instrument air, nitrogen and or other non-flammable neutral, dry fluids Operation: Solenoid, indirectly controlled Mounting position: Optional; Impulse valves preferably horizontally Nominal diameter: ND 6 mm Port size: G /, / NPT, G /, / NPT Operating pressure:,5 to 8 bar with internal air supply to 8 bar with external air supply Temperature: Valve: - to +65 C Solenoid: see solenoid table (please consult our technical service for use below + C, if installed in the open protect all connections against the penetration of moisture!) Materials: Body: aluminium.65 with surface treatment for rough environmental conditions condensate test with alternating temperatures in sulphuric environment, salt spray test with different sodium chloride solutions, tested in ammonia environment Seals: NBR (special perbunan) Ordering information 5/ directional control valve with spring return, Port size G /, solenoid in protection class EEx me, V DC Type: internal air supply Type: Z external air supply EEx e cable gland M x,5 Type: 5888 Accessories See page 5 / 5/ 5 5 5/ 5 5/7 Our policy is one of continued research and development. We therefore reserve N/en

2 75 Inline /-, 5/- and 5/ directional valves Aluminium anodized body Symbol 5 5 Type Port size Function Actuation Operating pressure Flow Weight Dimensions (bar) (l/min) (kg) 755 * G / / Solenoid/Spring, bar,5 755 * / NPT / Solenoid/Spring, bar,5 75 * G / / Solenoid/Spring, bar 6, * / NPT / Solenoid/Spring, bar 6,5 755 * G / 5/ Solenoid/Spring, bar,7 755 * / NPT 5/ Solenoid/Spring, bar,7 75 * G / 5/ Solenoid/Spring, bar 6, * / NPT 5/ Solenoid/Spring, bar 6,7 755 * G / 5/ Solenoid/Solenoid, bar, * / NPT 5/ Solenoid/Solenoid, bar, * G / 5/ Solenoid/Solenoid mid position APB, bar 5, * / NPT 5/ Solenoid/Solenoid mid position APB, bar 5,7 6 Brass body Symbol Type Port size Function Actuation Operating pressure Flow Weight Dimensions (bar) (l/min) (kg) 765 * G / / Solenoid/Spring, bar, 765 * / NPT / Solenoid/Spring, bar, 76 * G / / Solenoid/Spring, bar 6, 7665 * / NPT / Solenoid/Spring, bar 6, 765 * G / 5/ Solenoid/Spring, bar,7 765 * / NPT 5/ Solenoid/Spring, bar,7 76 * 5 G / 5/ Solenoid/Spring, bar 6, * / NPT 5/ Solenoid/Spring, bar 6,7 765 * G / 5/ Solenoid/Solenoid, bar, * / NPT 5/ Solenoid/Solenoid, bar,7 5 5 Stainless steel body Symbol Type Port size Function Actuation Operating pressure Flow Weight Dimensions (bar) (l/min) (kg) 775 * G / / Solenoid/Spring, bar, 775 * / NPT / Solenoid/Spring, bar, 77 * G / / Solenoid/Spring, bar 6, 7765 * / NPT / Solenoid/Spring, bar 6, 775 * G / 5/ Solenoid/Spring, bar,8 775 * / NPT 5/ Solenoid/Spring, bar, * G / 5/ Solenoid/Spring, bar 6, * / NPT 5/ Solenoid/Spring, bar 6,8 775 * G / 5/ Solenoid/Solenoid, bar, * / NPT 5/ Solenoid/Solenoid, bar,8 5 5 When ordering please indicate solenoid, voltage and current type (frequency) Valve function: APB = All Ports Blocked Accessories on page 5 N/en Our policy is one of continued research and development. We therefore reserve 5/7

3 75 Inline Actuation solenoids Type Power consumption Rated current at Protection class Temp. range Electroport size Weight Dimensions Circuit V DC (W) V AC (VA) V DC (ma) V AC (ma) Ambient/Fluid C (kg) diagram 76 *7),, *5) 78 - IP w/o connector *5) DIN EN 75-8, IP65 with connector *5) Form A 8, EEx m II T *) m cable *5), 5 IP66 T C -,5-5 EEx m II T *) m cable, 5 7 IP66 T C *8),7 - - EEx me II T5/T6 *) (T5) M X,5 *6),85 6 IP66 T C (T6) *8) -, - 6 EEx me II T/T6 *) (T) M X,5 *6), IP66 T C (T6) 6 *8),7 - - EEx me II T5/T6 *) (T5) / NPT *6),85 7 EEx md II T5/T6 *) (T6) 6 *8),7 - - IP66 T C M X,5 *6) 6 *8) -, - 6 EEx me II T5/T6 *) (T5) / NPT *6), EEx md II T5/T6 *) (T6) 6 *8) -, - 6 IP66 T C M X,5 *6) Stainless steel 8,8 Ex mb d IIC T/T6 Cat. II G (gas), (T) or (T6) 8, 6 Ex mb e II T5/T6 Cat. II D (dust), 7 Ex mbd tda IP66 T C 7, XP (NEMA) *) Flying leads, 8, X, 6, 6P, 7, 5 mm long Standard voltages V DC, V AC. other voltages on request Design acc. to VDE 58, EN 5/58.% duty cycle. *) Categorie II GD, EC-Type-Examination-Certificate KEMA ATEX 7X *) Categorie II GD, EC-Type-Examination-Certificate KEMA 8 ATEX 5 X *) Categorie II GD, EC-Type-Examination-Certificate PTB ATEX 85 X *) CSA-LR 576-6, FM approved, for hazardous locations: Div. and, Class I, II, III *5) Required connector for DC: type Valves can be operated with DC only for V AC application please use V DC coil togetter with rectifier plug 665 *6) Cable gland is not indicated in delivery *7) IP65 according to DIN 5/IEC 5 and DIN EN *8) This solenoid has a fuse with an appropirate rating. Solenoid actuators for intrinsically-safe circuits, protection class EEx ia IIC T5/T6, cat.ii G, II D, IP66, T C, EC type examin. certificate KEMA ATEX 5X Type Nominal resist. RN coil Min. required Resistance switching current Rw 6coil * Required voltage at terminal Temperature range Ambient/fluid ( ) (ma) ( ) (Rw 6) T5 T6 (kg) C C, C C, C C, C C,85 6 Weight Dimensions Circuit diagram Cable gland is included in delivery When selecting an intrinsically safe power supply, the permissible maximum values according to the certificate should be taken in account. On the other hand, the low effective inductivityand capacity can be ignored. Solenoid actuators with FM-approval Instrinsically safe: IS/I, II, III//ABCDEFG/ T6 Ta = 65 C; I/ AEx ia IIC/ T6 Ta = 65 C /B; Entity Nonincendive: NI/I//ABCD/ T6 Ta = 65 C; S/II,III//FG/T6 Ta = 65 C; NEMA Type Type Nominal resist. Min. required Resistance Required voltage RN coil switching current Rw 6coil * at terminal ( ) (ma) ( ) (Rw 65) Temperature range Ambient/fluid (kg) 5 6, C, , C,8 8 8, C,8 8, C, , C, , C, , C, , C, , C,8 Weight Dimensions Circuit diagram 5/7 Our policy is one of continued research and development. We therefore reserve N/en

4 75 Inline /-, 5/- and 5/-directional control valves 5 mw/5 mw in protection class EEx ia IIC T/6 Aluminium anodized body Symbol Type Power Port size Function Actuation Operating pressure (bar) Flow (l/min) Weight (kg) Dimensions , mw G / / Solenoid/Spring, bar, , mw / NPT / Solenoid/Spring, bar, , mw G / / Solenoid/Spring, bar 6, , mw / NPT / Solenoid/Spring, bar 6, , mw G / 5/ Solenoid/Spring, bar, , mw / NPT 5/ Solenoid/Spring, bar, , mw G / 5/ Solenoid/Spring, bar 6, , mw / NPT 5/ Solenoid/Spring, bar 6, , mw G / 5/ Solenoid/Solenoid, bar, , mw / NPT 5/ Solenoid/Solenoid, bar,7 5 5 Brass body Stainless steel body , mw G / 5/ Solenoid/Solenoid mid position APB, bar 5, , mw / NPT 5/ Solenoid/Solenoid mid position APB, bar 5,7 Symbol Type Power Port size Function Actuation Operating pressure (bar) Flow (l/min) Weight (kg) Dimensions , mw G / / Solenoid/Spring, bar, , mw / NPT / Solenoid/Spring, bar, , mw G / / Solenoid/Spring, bar 6, , mw / NPT / Solenoid/Spring, bar 6, , mw G / 5/ Solenoid/Spring, bar, , mw / NPT 5/ Solenoid/Spring, bar, , mw G / 5/ Solenoid/Spring, bar 6, , mw / NPT 5/ Solenoid/Spring, bar 6, , mw G / 5/ Solenoid/Solenoid, bar, , mw / NPT 5/ Solenoid/Solenoid, bar,7 5 Symbol Type Power Port size Function Actuation Operating pressure (bar) Flow (l/min) Weight (kg) Dimensions , mw G / / Solenoid/Spring, bar, , mw / NPT / Solenoid/Spring, bar, , mw G / / Solenoid/Spring, bar 6, , mw / NPT / Solenoid/Spring, bar 6, , mw G / 5/ Solenoid/Spring, bar, , mw / NPT 5/ Solenoid/Spring, bar, , mw G / 5/ Solenoid/Spring, bar 6, , mw / NPT 5/ Solenoid/Spring, bar 6, , mw G / 5/ Solenoid/Solenoid, bar, , mw / NPT 5/ Solenoid/Solenoid, bar,8 5 code for electrical connection: standard: 5 = M 6 x,5 Ordering examples valve pilot 6, mw electr. connection internal air supply 5 M6 x,5 cable gland Z external air supply Solenoid operators protection class EEx ia II C T/T6 Type Power Resistance coil max. values EEx i Type of protection Ambient temperature P (+ C) Uon (+ C) Uon (+8 C) Uoff (+ C) Uoff (-5 C) Iein R (+ C) Ui Ii Pi *) 5 V 5 ma 5 mw 7 V 5 ma 5 mw 85 6, mw, V 5, V, V, V,5 ma 8 8 V 5 ma 5 mw EEx ia IIC T - bis +8 C 86, mw 6 V 6,8 V 5, V,7 V,5 ma V ma 5 mw EEx ia IIC T6 - bis +6 C V 85 ma 5 mw *) Categorie IIG, EC-Examination certificate no. PTB 6 ATEX U Air consumption: home position 6 l/h, operating position 5 l/h Switch-on Switch-on Switch-off Switch-off Rated voltage voltage voltage voltage current Circuit diagram N/en Our policy is one of continued research and development. We therefore reserve 5/7

5 75 Inline Accessories Manual override Silencer Flow regulator Cable gland for outdoor use with Protection class EEx e, EEx d (ATEX), non-return diaphragm Ms nickel plated brass Connectors 886 (without detent) *) 6 (G/) *) 676 (G/) *) EEx e 5888 (for solenoid xx / 6xx M x,5) (with detent) *) 8 (G/) *) EEx d (for solenoid 6xx M x,5) 66 (with rectifier) EEx e, EEx d (ATEX) 5885 (for solenoid 6xx /- NPT) EEx e, EEx d (ATEX) 5885 (für Magnet 6xx /- NPT) II G/D EEx d IIC 5887 (für Magnet 8xx Mx,5; Ø... mm) II G/D EEx e II 5885 (für Magnet 8xx Mx,5; Ø... mm) For detailed information about connectors see page : N/UK 7.7. *) For indoors use *) Useable only with the valves on page *) Throttle exhaust port can be protected from penetration of liquids, dirt etc. Basic dimensions valves ➀ ➁ 8 5 6, ~7 6 ~ 5,5,5,5,5 8,5,5 5,5 A - A Solenoid dimensions see page External control pressure connection G/8 Working port G/, G/ or / NPT, / NPT Position of gasket internal pilot air Position of gasket external pilot air 5/7 Our policy is one of continued research and development. We therefore reserve N/en

6 75 Inline ➂ ~7 6 ➃ ~5, A - A Solenoid dimensions see page External control pressure connection G/8 Working port G/, G/ or / NPT, / NPT Position of gasket internal pilot air Position of gasket external pilot air N/en Our policy is one of continued research and development. We therefore reserve 5/7

7 75 Inline ➄ 5 B B 6 A - A ~ ➅ ~ B B B - B 7 Solenoid dimensions see page External control pressure connection G/8 Working port G/, G/ or / NPT, / NPT Position of gasket internal pilot air Position of gasket external pilot air 5/7 Our policy is one of continued research and development. We therefore reserve N/en

8 75 Inline ➆ ➇ C-C 7 C C,5 7 C C,5 int. P P ext ,5,5,5,5,5,5 6,5 6,5,5,5 ➈ ➉ 7 C C c c 5 77,5 7 8,5,5 66,5,5, Electrical connection 5 7 External control pressure connection G/8 Working port G/, G/ or / NPT, / NPT Electrical connection, M6x,5 Position of gasket internal pilot air Position of gasket external pilot air N/en Our policy is one of continued research and development. We therefore reserve 5/7

9 75 Inline C-C 7 C C 5 D D,5 int. P P ext D-D ca. 7 C C ~ 5 D D int. P P ext Electrical connection 5 External control pressure connection G/8 7 Working port G/, G/ or / NPT, / NPT Electrical connection, M6x,5 Position of gasket internal pilot air Position of gasket external pilot air 5/7 Our policy is one of continued research and development. We therefore reserve N/en

10 75 Inline 5 6 7,5 8 6,5, Pg 8,5 8,5 7, ,5,5 7 7,5 / - NPT,5 6,5,5 7 M x, ,5 6 6 /- NPT Connector can be indexed by x Ø 6 or (with spacer tube) M x,5 or / - NPT Flying leads AWG 8 (5 mm long) N/en Our policy is one of continued research and development. We therefore reserve 5/7

11 75 Inline Circuit diagrams ➀ ➃ ➄ ➅ ➆ Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. 5/7 Our policy is one of continued research and development. We therefore reserve N/en

Our policy is one of continued research and development. We therefore reserve the right

Our policy is one of continued research and development. We therefore reserve the right 970 Namur /-, /- and /-Directional control valves Electromagnetic indirectly controlled soft seal spool valves G /4, /4 NPT NAMUR-interface For single and double operated actuators Exhaust air recirculation

More information

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

For single and double operated actuators. Exhaust air recirculation (3/2 way function) For single and double operated actuators /-, 5/- and 5/ Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4 or /4 NPT NAMUR interface Exhaust

More information

97100 NAMUR. Technical data

97100 NAMUR. Technical data 9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators

More information

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx***** HERION 9805 SERIES Indirect solenoid actuated poppet valves with NMUR interface / - Internal thread G/, / NPT or flanged Main application: single operated actuators TÜV-approval based on IE 6 508,DIN V

More information

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT 97 Inline /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT For single and double operated actuators Crossover-free switching, switch-over function guaranteed even with

More information

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching

More information

Our policy is one of continued research and development. We therefore reserve the right

Our policy is one of continued research and development. We therefore reserve the right For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust

More information

HERION SERIES Indirect solenoid actuated soft seal

HERION SERIES Indirect solenoid actuated soft seal HERION 9700 SERIES Indirect solenoid actuated soft seal spool valves with NAMUR interface /, 5/ - G/ For single and double acting actuators Crossover-free switching, switchover function guaranteed even

More information

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 NMUR/INLINE / way poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators TÜV-approval based on type examination

More information

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components

More information

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en / poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated

More information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information 00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en 00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve

More information

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface 9700 NAMUR / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, NAMUR Interface For single and double acting actuators / or / way function in one valve Easily interchangeable

More information

24010, 3/2 Direct solenoid actuated poppet valve

24010, 3/2 Direct solenoid actuated poppet valve 00, / > / (G or NPT) Inline & NAMUR > Main application: Single acting actuators in intrinsically safe circuits > Approval according to IEC 68, multichannel up to SIL > Solenoid valve with low power consumption

More information

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface 3/ Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface Suitable for instrumental air, neutral gaseous and liquid fluids and

More information

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4 Working from 0 bar up Short switching times Suited for fine vacuum down to 1,33 10-3 mbar Assembled oil and grease-free For a.c. solenoid systems with integrated rectifier (40 to 60 Hz) These solenoid

More information

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves 60, 8007 NAMUR / & / > > Port size: G/ and NAMUR interface > > Easily interchangeable solenoid system > > For single and double operated actuators > > Standard manual override with detent > > Maintenance-free

More information

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers. 60, 60, 8007 For single- and double-acting drives /, / and / Directional Control Valves Modular NAMUR design Actuation: Electromagnetic Indirectly controlled spool valves Connections G /8, G /, / NPT Standard

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

High pressure valves. 80 to 350 bar

High pressure valves. 80 to 350 bar 80 to 350 bar High switchable p Hermetically sealed poppet valves Excellent repeatability of switching times Function even with lager voltage tolerance Compact design DN to DN 40 Technical data Medium:

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

Engineering GREAT Solutions

Engineering GREAT Solutions Engineering GREAT Solutions Process Express Precision. Engineered. Through our people, products and service. Contents 1 2 3 4 5 6 VALVES I/P & E/P CONVERTERS PRESSURE SWITCHES & SENSORS AIR PREPARATION

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and

More information

Nugget 40, V08 series

Nugget 40, V08 series Nugget 0, V0 series Integrally ported 5/ and 5/3 Spool valves Solenoid actuated and pilot operated Ø, Ø mm or High flow from mm body width Wide range of voltages available Low profile fixed length manifolds

More information

25000, 4/2 Direct solenoid actuated poppet valves

25000, 4/2 Direct solenoid actuated poppet valves > > Port size: /4, /2 > > Working from 0 bar up > > Suited for outdoor installation > > Suitable for vacuum range down.33 0-2 mbar l/s > > : 65, Ex em, Ex d TEX approved (see solenoid table) Technical

More information

N/** поставка оборудования для подготовки воздуха

N/** поставка оборудования для подготовки воздуха M/0000 Series Inline /, 5/ and 5/ Spool Valves Solenoid and Pilot Actuated G / Low power solenoids High flow Unique steel reinforced seals Light weight corrosion resistant materials Technical Data Medium:

More information

Hydraulic pressure switch 20D Acc. to ATEX

Hydraulic pressure switch 20D Acc. to ATEX Acc. to ATEX 5 to 400 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector

More information

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Modular design - Maxseal valves ypass function enables valve removal online Stainless

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

Direct-acting 3/2 way plunger valve

Direct-acting 3/2 way plunger valve Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type

More information

3/2-way Rocker Solenoid Valve for pneumatic systems

3/2-way Rocker Solenoid Valve for pneumatic systems 3/-way Rocker Solenoid Valve for pneumatic systems EEx ia versions Direct-acting High cycling rate Reduced power consumption Type 6104 can be combined with... Sub-base connection Approvals: Type 654 Servo-assisted

More information

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend,

02/97 N/** Our policy is one of continued research and development. We therefore reserve the right to amend, Nugget 0 V0 Series Integrally Ported 5/2 and 5/3 Spool Valves Solenoid Actuated and Pilot Operated Ø, Ø mm or High flow from mm body width Low power solenoids with a range of voltages Use valves singly

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals 5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO 5599- #, #2, #3, #4 Steel reinforced main seals 6 bar and 0 bar CNOMO solenoid pilots with locking or non-locking manual override Low

More information

2/2 Pressure operated valves

2/2 Pressure operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54

More information

A robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79U and PremiAir.

A robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79U and PremiAir. VI F79N Namur Solenoid Valve robust, pilot operated solenoid valve for direct mounting to pneumatic actuators Figure 79E/79 and Premiir. Features ompact design with standardized market proven NMR mounting

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65. Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx

More information

Allfluid pressure switches 20D to ATEX

Allfluid pressure switches 20D to ATEX -1... 63 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector M20 x

More information

BETA SWITCHES FOR HAZARDOUS AREA

BETA SWITCHES FOR HAZARDOUS AREA BETA offers complete line of switches for (classified) hazardous locations! The BETA Switch, well known as a safety instrument, adds an extra dimension to industrial safety by having area approval up to

More information

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated > > Port size: G/8 & G/4 > > Low and high power solenoid coil options > > End, side or face mounting solenoids > > Light weight corrosion resistant materials > > Option for manual override acting directly

More information

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

-V- New. Valve series VOFC. 2009/08 Subject to change Internet: Valve series VOFC 2009/08 Subject to change Internet: www.festo.com/catalogue/... 159 Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way

More information

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm). /2- and 4/2-multi-way valves ; servo-assisted; block assembly or NAMUR flange; DN 4; flow rate: 00 l/min Advantages / Benefits II 2G EEx ia IIC T6 PTB0 ATEX 275 approved Available for block assembly and

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2

More information

AUTO STAR with central connector M12x1

AUTO STAR with central connector M12x1 with central connector M2x Non corrosive spool and sleeve for long trouble free life 5/2 and Glandless Valves Actuated Sub-base Mounted ISO 5599- #, #2, #3 6 bar (4,5 W) and 0 bar (2 W) 24V DC solenoids

More information

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S) XSz 8V & XSz 0V 5/ directional control valve with dynamic monitoring For mechanical presses and other safety applications G/4, G/, /4 NPT & / NPT Inherently fail-safe without residual pressure Dynamic

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 3/2-way Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2 W 142 = 24 V DC, 4.2 W 152 = 24 V AC, 7/4 VA 156 = 115 V AC,

More information

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated ICOS - /, / or 5/ Exia poppet valves > > Port size: /... / (ISO G/NPT) /... (Flanged) > > Zone 0, Exia solenoid pilot operated valve > > Safety integrity level and > > Reliable and long life, ideal for

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve

More information

Extremely sturdy and corrosion-resistant Solenoid valves VOFC/VOFD and solenoid coils VACC. Selection and ordering

Extremely sturdy and corrosion-resistant Solenoid valves VOFC/VOFD and solenoid coils VACC. Selection and ordering Extremely sturdy and corrosion-resistant Solenoid valves VOFC/VOFD and solenoid coils VACC Intrinsically safe solenoid coil VACC-S13-...-EX4A Encapsulated solenoid coil VACC-S13-...-EX4ME Encapsulated

More information

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending The V-Solenoid II Standard Series ATEX EX Series Intrinsically Safe Series ExProof

More information

Direct-acting 2/2- or 3/2-way pivoted armature valve

Direct-acting 2/2- or 3/2-way pivoted armature valve 0330 Direct-acting 2/2- or 3/2-way pivoted armature valve Direct-acting, media-separated valve with diameter of up to DN 5 Maintenance-free pivoted armature technology Vibration-proof, block screwed coil

More information

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact

More information

Accessories Cable glands

Accessories Cable glands Accessories Cable glands 235 Technical data Cable glands Brass hexagon cable gland Brass sealing cable gland Material: Brass, nickel-plated Gasket: Soft rubber Protection type IP 54 Additional information:

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2 Series 0 D Pressure switches for all-fluid technique Port sizes and Microswitch with gold-plated contacts (silver plated for outdoor variants) Plug-in connection to DIN 4650 Technical Data Fluid: Neutral

More information

SKINNER Intrinsically Safe Series Four-Way

SKINNER Intrinsically Safe Series Four-Way SKINNER Four-Way Two-Position Valves SPECIFICATIONS Mechanical Characteristics Standard Materials of Body Aluminum Seals FKM, NBR. Other diaphragm materials available upon request. Compatible Fluids Air

More information

Pneumatic control unit for decentralized automation of ELEMENT process valves

Pneumatic control unit for decentralized automation of ELEMENT process valves 890 Pneumatic control unit for decentralized automation of ELEMENT process valves Type 890 can be combined with... Compact design Integrated pilot valve with manual override Integrated control air routing

More information

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS Solenoid coils Solenoid coils Product range overview Version Type For valve series Page/ Internet MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS F solenoid coil MSF VACF 3 N solenoid coil VACN-N 6 N

More information

High Flow Valve Actuation Range. NAMUR Valves G1/4" & G1/2" Piped Valves G1/4" & G1/2" Banjo Valves G1/8" & G1/4"

High Flow Valve Actuation Range. NAMUR Valves G1/4 & G1/2 Piped Valves G1/4 & G1/2 Banjo Valves G1/8 & G1/4 31-37 High flow NAMUR valves G1/ and G1/ aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding High Flow Valve Actuation

More information

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves

V44/V45 series, 2 x 3/2, 5/2 & 5/3 Mini ISO Valves V/V series, x /, / & / > > x/, / and / valves, ISO 07-/ VDMA 6, Size 6 mm > > Solenoid and pilot actuated > > High performance, compact design > > Flexible sub-base system > > Multipressure system capability

More information

COILS, CONNECTORS, SOLENOID VALVES

COILS, CONNECTORS, SOLENOID VALVES COILS, CONNECTORS, SOLENOID VALVES 117 10 mm solenoids Solenoid valve 10 mm 00.441.0 Tension 24V DC ±10% Temperature range -5 C...+60 C (23 F... 140 F) Power 0.5... 1 W Operating pressure 0... 7 bar (0...

More information

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES CONTINENTAL HYDRAULICS VED*HL-*-KD2 HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES (IN COMPLIANCE WITH ATEX 94/4/EC) 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 /

More information

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide

Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide Multi Way Valves for Pneumatics Servo Assisted, Extendable, 10mm Wide 3/2 and 5/2 Way Valves Optimum system solutions due to high level of modularity Maintenance free and little wear due to high level

More information

3-Way Solenoid Valve - Direct Acting

3-Way Solenoid Valve - Direct Acting 3-Way Solenoid Valve - Direct Acting General application valves for dry or lubricated air, neutral gases and liquids Description: Applications: 3-Way Solenoid Valve - Direct Acting - Normally Closed. Coil

More information

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control Flowserve Solutions to Keep You Flowing Flowserve is one of the world s leading providers of fluid

More information

Series MI-01, MI-02, MI-03

Series MI-01, MI-02, MI-03 Valves > standardized valves > electrically operated > Series MI-01, MI-02, MI-03 ISO 99/1, Size 1 to 3 Technical details Series Connection MI-01, MI-02, MI-03 ISO 99/1 Nominal size Temperature range Medium

More information

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv)

Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/ Nl/min (3.354 Cv) Electrically operated valves Series M-22, 3/2-, 5/2- and 5/3-way G1/2 3300 Nl/min (3.35 Cv) Order code Series and function M-22-310-HN-12 Standard coils 1) 11 = 12 V DC,,2 W 12 = 2 V DC,,2 W 22 = 2 V AC,

More information

Electrically operated spool valve. The manual override is detent and is operated by screw driver.

Electrically operated spool valve. The manual override is detent and is operated by screw driver. Valves > electrically operated valves > Series M-07 Technical details Connection G1/ Nominal size Temperature range Medium Series M-07 page Materials 9 mm -10 C... +70 C Filtered, oil-free and dried compressed

More information

Series 581 ISO Pneumatic Directional Control Valves

Series 581 ISO Pneumatic Directional Control Valves Series 581 ISO 5599-1 Pneumatic Directional Control Valves Series 581 Pneumatic Valves 01_1 st Headline_36 pt/14.4 mm 4-Way ISO Directional Control second line Series 581 - A complete series of standardized

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

General Specifications DRV DRV-Exm DRV-Exd

General Specifications DRV DRV-Exm DRV-Exd direct operated, 3-way pressure reducing valve Q max = 8 l/min pressure range = - 5 bar body stainless steel (optional) Description The proportional pressure reducing valve (3-way function) is used to

More information

Pilot operated solenoid valves for pneumatic actuators

Pilot operated solenoid valves for pneumatic actuators Pilot solenoid valves for pneumatic actuators 3 / 2 and 5 / 2 way solenoid valves Orifice size 6 and 12 mm NAMUR and threaded connections Pressure range 0 (2) 8 bar For air and inert gases With TÜV-approval

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use

More information

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4 and 1 /2 5/2 Way Solenoid Valve 1 /4 6/2 Way Solenoid Valve 1 /4 5/3 Way Solenoid Valve 1 /4 /2 Way Pilot Valve /2 Way Solenoid Valve 1 /" and 1 /2" 5/2 Way Solenoid Valve 1 /" 6/2 Way Solenoid Valve 1 /" 5/ Way Solenoid Valve 1 /" General The solenoid valves consist of one or two /2 way pilot

More information

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES

VSD*HL-*-KD2 - HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES CONTINENTAL HYDRAULICS VSD*HL-*-KD2 HAZARDOUS LOCATION, SOLENOID, DIRECT & PILOT OPERATED VALVES (IN COMPLIANCE WITH ATEX 94/9/EC) 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

To order, quote model number from table overleaf, e. g for a DN 25 valve.

To order, quote model number from table overleaf, e. g for a DN 25 valve. 2/2-way valves DN 8 to DN 5 For neutral gases and liquid fluids Solenoid actuated, with forced lifting Diaphragm valves Internal threads /4 to G 2 or 1/4 N to 2 N Operating pressure to / 16 bar Description

More information

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm / or 3/-way Solenoid Valve, with pivoted armature and isolating diaphragm Type 0330 can be combined with Lockable manual override as standard For liquid, gaseous and aggressive media Long service life,

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/06/en No. 50078457 Electromagnetic Flow Monitor magphant Monitoring and measurement Flow monitoring with selectable limit values (relay output) Flow measurement via 4...20

More information

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv) Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/4 1300 and 1580 Nl/min (1.321 and 1.606 Cv) Order code Series and function M-07-310-HN-442 Standard coil HN at port 2 + 4 HN at port

More information

GTV Series High Pressure Control Valves

GTV Series High Pressure Control Valves For primary and secondary shut off of fuel control lines Keeping the World Flowing Contents Section Page Technical Specification 3 ¾" & " 2-Way Poppet Valve 4 ¾" & " 3-Way Poppet Valve 5 /2", 2" & 3" 2-Way

More information

Acoustic Signals Industrial Airhorns > AP Series Product overview

Acoustic Signals Industrial Airhorns > AP Series Product overview udible Signals INDUSTRIL IRHORNS SOUNDERS coustic Signals Industrial irhorns > Series roduct overview The Series of air horns are suitable for general purpose signalling where high output is required such

More information

/2-way piston valves

/2-way piston valves > > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring

More information

5/2 and 5/3 Way Valves

5/2 and 5/3 Way Valves Caracteristics to VDI 9 Pressures quoted as gauge pressure Characteristics Symbol Unit Description General Features Ceramic Spool Valve Mounting On base plate, Tube connection Base plate Port size G1/

More information

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact: Solenoid operated EEx d IIC T6 Description of the Valve Directional control valves direct the flow in various directions (P A with 2/2 valves and P A // A T) with 3/2 valves. Available as 2/2 and 3/2 valves,

More information

Solenoid valves VUVS/valve manifold VTUS, NPT

Solenoid valves VUVS/valve manifold VTUS, NPT Solenoid valves VUVS/valve manifold VTUS, NPT -V- New VUVS-LT25, VTUS-25 Solenoid valves VUVS/valve manifold VTUS, NPT Key features Innovative Versatile Reliable Easy to install A reliable, heavy-duty

More information

Integrated Control modules

Integrated Control modules .60.0 Rev. 0 Page of 9 Integrated Control modules QC, QC2 and QC Features: - Basic actuator functions for: - Spring return applications, or - Double acting applications or, - Double acting Fail in Last

More information

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1 15 mm Pilot Valve The 15 mm pilot valve has been designed and developped by Amisco as a logical evolution of the traditional product range manufactured for the pneumatic market. The 15 mm solenoid valve

More information

Solenoid valves VZWM-L, NPT

Solenoid valves VZWM-L, NPT Key features and type codes General Indirectly actuated diaphragm valve Process valve connection N14 N2 Flow rate 1400 31000 l/min Available in brass or stainless steel casting Wide range of coils VZWM

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Application Single-acting or double-acting positioners for attachment to pneumatic control valves. Supplied with a pneumatic input signal

More information