Material pressure (bar) (Cv (US) kv x 1,2 Seat

Size: px
Start display at page:

Download "Material pressure (bar) (Cv (US) kv x 1,2 Seat"

Transcription

1 00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve also suitable for low power consumption in non hazardous areas without barrier Working from 0 bar up High operational reliability even after long periods of inoperation Suitable for control and instrument quality air Also suitable for open air installation Namur flange with integrated exhaust air recirculation Solenoid: ATEX category II GD, type of protection Ex ia IIC T/T6, EX td A IP66 T9 C, suitable for zones, (gases) and, (dusts) DIN EN 608 IEC 608 up to SIL Approval depends on magnetic system, see page! Technical features Medium: Compressed air, filtered, nonlubricated and dry Other fluids on request Operation: Direct solenoid operated poppet valves Flow direction: Optional Mounting position: Any, but preferably with solenoid vertical Port size: G /, / NPT or flanged with NAMUR Interface Operating pressure: bar Fluid/Ambient temperature: C Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below + C. For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: brass.00 (Ms 8), stainless steel.0 (6 L) hard-anodised aluminium.06 Internal parts: stainless steel, brass Solenoid housing: aluminium, anodized hartanodisiert.06 Seals: NBR Technical data Symbol Port size Operating *) kv-wert Material Weight without Dimension Model *) pressure (bar) (Cv (US) kv x, Seat Housing solenoid (kg) No. G / NBR Brass 0, / NPT NBR Brass 0, G / NBR Stainless steel 0, / NPT NBR Stainless steel 0, G / NAMUR NBR Aluminium *) 0, / NPT NAMUR NBR Aluminium *) 0, G / NAMUR *) NBR Aluminium *) 0, *) With gaseous and liquid fluids up to 0 mm /s *) Hard-anodised *) P port in flange interface *) Manual override on requst Note: At an ambient temperature of -0 C, higher air consumption may be experienced for short periods. 8/ N/en/en..09.0

2 00 Solenoid parameters for use in non harardous locations Switch-on voltage Allowed current Holding current Power consumption (V) (ma) (ma) (W)... 6, < 7 > 0,8 at V Ex-Protection IP-Protection class (to EN 609) Temperature Ambient/Fluid Electrical connection Weight Operating sequence ( C) (kg) IP M0 x, *6) 0,8 see below 00 Model Standard voltages (±0%), Design according to VDE 080, EN 00/ % duty cycle. Pick-up delay typical: 0,... s, depending on intrinsical current supply *6) Connector cable gland is in scope of delivery Solenoid parameters for use in intrinsically safe circuits Symbol Switch-on voltage (V) Holding current min. (ma) Holding voltage (V) Pick-up delay typical *) (s) Protection class Temperature Ambient/Fluid ( C) Weight (kg) Model approx. 0,... IIG Ex ia IIC T6 IIG Ex ia IIC T IID IP66 T9 C ,8 00 *) depending on intrinsical current supply Operating sequence ON OF U (V) I (ma) t t t Supply voltage Capacitor charging voltage Solenoid current Valve status Model Approvals Datasheet ATEX IECEx FM 00 PTB 0 ATEX 00 IECEx PTB N/en 7.. Function of solenoid drive To switch the direct operated valve, a certain energy is required. This energy is stored in a capacitor. The charging voltage is V. The higher the supply voltage, the shorter the charging time. As soon as the charging voltage has been reached, the valve switches. The small current now flowing through the coil is sufficient to hold the valve in the open position. At least 0 ma are required for this. Current supply units: Intrinsically safe power supply units can be choosen in a list of compatibility in When selecting an intrinsically safe power supply, it is important to observe the maximum permissible values acc. to the EC-Type-Examination Certificate PTB 0 ATEX 00 respectively IECEx PTB Ui 8 V, li 0 ma, Pi, W. The effective internal capacities Ci; and inductivities li of the solenoid are egligibly low. Accessories Silencer *) Exhaust guard *) Filter Throttle control plate Flange plate Yoke M/S (G/) 06 (G/, / NPT) 0687 (G/, / NPT) 009 (for G/ only) (NAMUR single connection plate, for G/ only) 009 C/S (/ NPT) *) For indoors use only *) For outdoors use, opening pressure ~ 0, bar Page 0679 (NAMUR-rip use in combination with 06790, Alu) N/en/en /

3 00 Dimensions Valves 70, 70, ~ 08,, 98 ~ 08 98, 0, 7,,, 7 0 Port size G / or / NPT For cable Ø... 9 mm 8/ N/en/en..09.0

4 , 0 ~ 0 7, M,, 7, G / 6, 9 G / ø, ø 9, G / 9, 6,, 6, , 0 0 6, 7, M ø0 M6, G / 9,,, 6,, 6, 7, 6 7 ø, G / ø 9, 0 Port size G / or / NPT mm deep For cable Ø... 9 mm N/en/en /

5 00 Circuit diagram NAMUR hole pattern (driving side) M Port (A) Coding stud threaded M (0 deep) Port (R) NAMUR quick exhaust module for a better kv-value by exhaust see data sheet..80 NAMUR interlinking plates in redundancy design for»safety exhausting«and»safety ventilating«see data sheet..80 Single connection plate Model: , M (x) NAMUR slot in combination with Model: 0679, 0 ø 9, 0 9 6, G / 9, 6 9,, 9, ø, G / 60 ø 9 ø, 7 8/ N/en/en..09.0

6 00 Yoke Model: 009 Throttle control plate Model: x 9,, 0 Silencer Model: M/S, C/S Exhaust guard Model: 06, 8 6, 0 ø, / ø / 0 M , M, B B, A A Filter Model: 0687, 8, 60 Ø 0, 60 Thread pitch diameter max.,8 mm Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in pneumatic systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. Functional safety (SIL): Suitable for certain applications can only be evaluated through examination of each safety-related overall system with regard to the requirements of IEC 608/6. N/en/en /

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en 00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable

More information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information 00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled

More information

24010, 3/2 Direct solenoid actuated poppet valve

24010, 3/2 Direct solenoid actuated poppet valve 00, / > / (G or NPT) Inline & NAMUR > Main application: Single acting actuators in intrinsically safe circuits > Approval according to IEC 68, multichannel up to SIL > Solenoid valve with low power consumption

More information

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface 9700 NAMUR / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, NAMUR Interface For single and double acting actuators / or / way function in one valve Easily interchangeable

More information

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components

More information

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface 9805 NMUR/INLINE / way poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators TÜV-approval based on type examination

More information

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves 60, 8007 NAMUR / & / > > Port size: G/ and NAMUR interface > > Easily interchangeable solenoid system > > For single and double operated actuators > > Standard manual override with detent > > Maintenance-free

More information

97100 NAMUR. Technical data

97100 NAMUR. Technical data 9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators

More information

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT 97 Inline /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT For single and double operated actuators Crossover-free switching, switch-over function guaranteed even with

More information

Operating pressure (bar) kv factor (m 3 /h) *3)

Operating pressure (bar) kv factor (m 3 /h) *3) / poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For

More information

97105 Inline. Ordering information. Technical data. Accessories See page 5

97105 Inline. Ordering information. Technical data. Accessories See page 5 75 Inline /-, 5/- and 5/ directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves G /, / NPT, G /, / NPT For single and double operated actuators Crossover-free switching,

More information

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en / poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated

More information

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

For single and double operated actuators. Exhaust air recirculation (3/2 way function) For single and double operated actuators /-, 5/- and 5/ Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4 or /4 NPT NAMUR interface Exhaust

More information

HERION SERIES Indirect solenoid actuated soft seal

HERION SERIES Indirect solenoid actuated soft seal HERION 9700 SERIES Indirect solenoid actuated soft seal spool valves with NAMUR interface /, 5/ - G/ For single and double acting actuators Crossover-free switching, switchover function guaranteed even

More information

Our policy is one of continued research and development. We therefore reserve the right

Our policy is one of continued research and development. We therefore reserve the right For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust

More information

Our policy is one of continued research and development. We therefore reserve the right

Our policy is one of continued research and development. We therefore reserve the right 970 Namur /-, /- and /-Directional control valves Electromagnetic indirectly controlled soft seal spool valves G /4, /4 NPT NAMUR-interface For single and double operated actuators Exhaust air recirculation

More information

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en

2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Modular design - Maxseal valves ypass function enables valve removal online Stainless

More information

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers. 60, 60, 8007 For single- and double-acting drives /, / and / Directional Control Valves Modular NAMUR design Actuation: Electromagnetic Indirectly controlled spool valves Connections G /8, G /, / NPT Standard

More information

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface 3/ Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface Suitable for instrumental air, neutral gaseous and liquid fluids and

More information

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****

Flow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx***** HERION 9805 SERIES Indirect solenoid actuated poppet valves with NMUR interface / - Internal thread G/, / NPT or flanged Main application: single operated actuators TÜV-approval based on IE 6 508,DIN V

More information

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching

More information

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated ICOS - /, / or 5/ Exia poppet valves > > Port size: /... / (ISO G/NPT) /... (Flanged) > > Zone 0, Exia solenoid pilot operated valve > > Safety integrity level and > > Reliable and long life, ideal for

More information

25000, 4/2 Direct solenoid actuated poppet valves

25000, 4/2 Direct solenoid actuated poppet valves > > Port size: /4, /2 > > Working from 0 bar up > > Suited for outdoor installation > > Suitable for vacuum range down.33 0-2 mbar l/s > > : 65, Ex em, Ex d TEX approved (see solenoid table) Technical

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and

More information

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve 3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for

More information

Hydraulic pressure switch 20D Acc. to ATEX

Hydraulic pressure switch 20D Acc. to ATEX Acc. to ATEX 5 to 400 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector

More information

High pressure valves. 80 to 350 bar

High pressure valves. 80 to 350 bar 80 to 350 bar High switchable p Hermetically sealed poppet valves Excellent repeatability of switching times Function even with lager voltage tolerance Compact design DN to DN 40 Technical data Medium:

More information

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4 Working from 0 bar up Short switching times Suited for fine vacuum down to 1,33 10-3 mbar Assembled oil and grease-free For a.c. solenoid systems with integrated rectifier (40 to 60 Hz) These solenoid

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated > > Port size: G/8 & G/4 > > Low and high power solenoid coil options > > End, side or face mounting solenoids > > Light weight corrosion resistant materials > > Option for manual override acting directly

More information

Direct-acting 3/2 way plunger valve

Direct-acting 3/2 way plunger valve Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

-V- New. Valve series VOFC. 2009/08 Subject to change Internet: Valve series VOFC 2009/08 Subject to change Internet: www.festo.com/catalogue/... 159 Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way

More information

Limit Switch Type 4747

Limit Switch Type 4747 Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical

More information

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).

The extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm). /2- and 4/2-multi-way valves ; servo-assisted; block assembly or NAMUR flange; DN 4; flow rate: 00 l/min Advantages / Benefits II 2G EEx ia IIC T6 PTB0 ATEX 275 approved Available for block assembly and

More information

Engineering GREAT Solutions

Engineering GREAT Solutions Engineering GREAT Solutions Process Express Precision. Engineered. Through our people, products and service. Contents 1 2 3 4 5 6 VALVES I/P & E/P CONVERTERS PRESSURE SWITCHES & SENSORS AIR PREPARATION

More information

Electronic Limit Switch Type

Electronic Limit Switch Type Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.

More information

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)

3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S) XSz 8V & XSz 0V 5/ directional control valve with dynamic monitoring For mechanical presses and other safety applications G/4, G/, /4 NPT & / NPT Inherently fail-safe without residual pressure Dynamic

More information

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control

More information

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4

VP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4 -way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G /... G / All-digital control electronics Variable pressure control Optional: serial interface with

More information

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, / 0 0 /-/ Série FEATURES The monostable spool valves have TÜV certified IEC 608 Functional

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals

5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals 5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO 5599- #, #2, #3, #4 Steel reinforced main seals 6 bar and 0 bar CNOMO solenoid pilots with locking or non-locking manual override Low

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

Allfluid pressure switches 20D to ATEX

Allfluid pressure switches 20D to ATEX -1... 63 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector M20 x

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2

More information

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de

More information

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4 SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 4 2 5 4 2 5 4 2 5 4 2 5 5/2 Series 55 FEATURES The monostable spool valves have TÜV certified

More information

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142 3/2-way Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2 W 142 = 24 V DC, 4.2 W 152 = 24 V AC, 7/4 VA 156 = 115 V AC,

More information

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4 SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 NC 0 0 / Series 55 FEATURES The monostable spool valves have TÜV certified IEC 6508

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve

More information

T84T - Excelon Plus Modular System 3/2 shut-off valve

T84T - Excelon Plus Modular System 3/2 shut-off valve > Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > 3/2 way function > Threaded exhaust port > Lockable in closed

More information

Type Electronic Limit Switch

Type Electronic Limit Switch Type 3738-20 Electronic Limit Switch With optional solenoid valve Application Electronic limit switch for on/off applications to indicate the end position. Optionally with integrated solenoid valve. Special

More information

Weight (kg) Model L92C- P-ETN. N/en

Weight (kg) Model L92C- P-ETN. N/en Excelon Pro Lubricator - Oil Fog ø 6... mm, G /8... G /8 Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air Operating pressure:

More information

/2-way piston valves

/2-way piston valves > > ort size: DN 15... 100 Flange connection, ressure rating N 40 > > Valve operates without differential pressure (Zero delta ) > > Suitable for vacuum > > djustable: Damped operation () > > Valve piston

More information

/2-way piston valves

/2-way piston valves > > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring

More information

SBM TECHNOLOGY Cooling / Air Recovery Valve

SBM TECHNOLOGY Cooling / Air Recovery Valve SBM TECHNOLOGY Cooling / Air Recovery Valve Part no. VSP15203x Advanced high pressure seal technology Integrated non-return valve Robust, compact & lightweight design Proven & reliable technology Maintenance

More information

3/2-way Rocker Solenoid Valve for pneumatic systems

3/2-way Rocker Solenoid Valve for pneumatic systems 3/-way Rocker Solenoid Valve for pneumatic systems EEx ia versions Direct-acting High cycling rate Reduced power consumption Type 6104 can be combined with... Sub-base connection Approvals: Type 654 Servo-assisted

More information

Nugget 40, V08 series

Nugget 40, V08 series Nugget 0, V0 series Integrally ported 5/ and 5/3 Spool valves Solenoid actuated and pilot operated Ø, Ø mm or High flow from mm body width Wide range of voltages available Low profile fixed length manifolds

More information

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS Solenoid coils Solenoid coils Product range overview Version Type For valve series Page/ Internet MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS F solenoid coil MSF VACF 3 N solenoid coil VACN-N 6 N

More information

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4 to 1 NPT 4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh

More information

I Ex-control stations I

I Ex-control stations I Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters System 6000 Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters Edition April 2018 Information Sheet T 6000 EN Electropneumatic Converters i/p converters

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Drain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element

Drain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element BL9 Excelon Pro Combination unit Filter/Regulator and Lubricator ø mm, G / Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air

More information

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional: serial interface with VP-Tool Software > > Optional

More information

2/2 Pressure operated valves

2/2 Pressure operated valves Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54

More information

N/** поставка оборудования для подготовки воздуха

N/** поставка оборудования для подготовки воздуха M/0000 Series Inline /, 5/ and 5/ Spool Valves Solenoid and Pilot Actuated G / Low power solenoids High flow Unique steel reinforced seals Light weight corrosion resistant materials Technical Data Medium:

More information

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves

Offshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding courtesy of Statoil Offshore and Onshore Applications Lucifer TM 2/2

More information

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767

Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Application Single-acting or double-acting positioners for attachment to pneumatic control valves. Supplied with a pneumatic input signal

More information

Pilot operated solenoid valves for pneumatic actuators

Pilot operated solenoid valves for pneumatic actuators Pilot solenoid valves for pneumatic actuators 3 / 2 and 5 / 2 way solenoid valves Orifice size 6 and 12 mm NAMUR and threaded connections Pressure range 0 (2) 8 bar For air and inert gases With TÜV-approval

More information

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65. Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx

More information

Type 4746 Electric or Pneumatic Limit Switch

Type 4746 Electric or Pneumatic Limit Switch Type 4746 Electric or Pneumatic Limit Switch Application Limit switches with inductive, electric or pneumatic contacts for attachment to pneumatic or electric control valves, to Type 4763 Electropneumatic

More information

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2

Series 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2 Series 0 D Pressure switches for all-fluid technique Port sizes and Microswitch with gold-plated contacts (silver plated for outdoor variants) Plug-in connection to DIN 4650 Technical Data Fluid: Neutral

More information

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves

V03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves V0, V0, V05 (EXCEL ) / & / > > Port size: G/8, G/ > > Extensive range of power and orifice size options > > Choice of manual override > > Compact installation > > Removeable coil > > Standard exhaust diffuser

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket

More information

Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en

Drain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en BG, BB Excelon Pro General Purpose filter/regulator ø... mm, G /...G / Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air Operating

More information

Pneumatic control unit for decentralized automation of ELEMENT process valves

Pneumatic control unit for decentralized automation of ELEMENT process valves 890 Pneumatic control unit for decentralized automation of ELEMENT process valves Type 890 can be combined with... Compact design Integrated pilot valve with manual override Integrated control air routing

More information

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry

ATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000

More information

18D according to ATEX

18D according to ATEX Pneumatic ressure switch -... bar Hydraulic ressure switch 5... 4 bar For EX-alications according to ATEX 00 a: Zone 2 category ATEX 3G (gases) Zone 22 category ATEX 3D (dust) TÜV (technical insection

More information

P64F - Olympian Plus plug-in system Soft start/dump valves

P64F - Olympian Plus plug-in system Soft start/dump valves > Port size: /4... /4 (ISO G/PTF) > Solenoid, air pilot or manual operator > ssists machine designers in complying with the European Machineries Directive > High forward flow and capacity dump facility

More information

I Ex-safety switches I

I Ex-safety switches I 3-pole, 20 A Technical data Ex-safety switches 20 A for controlled three-phase drives Marking accd. to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99

More information

2/2-way Globe Valve for media up to +180 C, DN

2/2-way Globe Valve for media up to +180 C, DN 2/2-way Globe Valve for media up to +180 C, DN 10-100 Compact globe valve version Flange, threaded and welded ports as standard Stainless steel 316L valve body Available with flow direction below and above

More information

SBM TECHNOLOGY PET Blow Valve Block

SBM TECHNOLOGY PET Blow Valve Block Advanced high pressure seal technology Robust, compact & lightweight design Proven & reliable technology Maintenance & service friendly High flow rate exhaust function Minimal dead space volume (< 35ml)

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40

More information

I Ex-safety switches I

I Ex-safety switches I EMERGENCY STOP EMERGENCY STOP Technical data Ex-safety switches 12 A Marking accd. to 94/9/EC II 2 G Ex de IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX 1164 PTB 00 ATEX

More information

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending The V-Solenoid II Standard Series ATEX EX Series Intrinsically Safe Series ExProof

More information

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4 and 1 /2 5/2 Way Solenoid Valve 1 /4 6/2 Way Solenoid Valve 1 /4 5/3 Way Solenoid Valve 1 /4 /2 Way Pilot Valve /2 Way Solenoid Valve 1 /" and 1 /2" 5/2 Way Solenoid Valve 1 /" 6/2 Way Solenoid Valve 1 /" 5/ Way Solenoid Valve 1 /" General The solenoid valves consist of one or two /2 way pilot

More information

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C) Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.

More information

AUTO STAR with central connector M12x1

AUTO STAR with central connector M12x1 with central connector M2x Non corrosive spool and sleeve for long trouble free life 5/2 and Glandless Valves Actuated Sub-base Mounted ISO 5599- #, #2, #3 6 bar (4,5 W) and 0 bar (2 W) 24V DC solenoids

More information

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted

M/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted M8, M Miniature, 22 mm normally closed and normally open models Sub-base mounted and manifold mounted 32 Poppet Valves Electrically Actuated M5 Manual override as standard Encapsulated coils with very

More information

Direct-acting 2/2- or 3/2-way pivoted armature valve

Direct-acting 2/2- or 3/2-way pivoted armature valve 0330 Direct-acting 2/2- or 3/2-way pivoted armature valve Direct-acting, media-separated valve with diameter of up to DN 5 Maintenance-free pivoted armature technology Vibration-proof, block screwed coil

More information

Compact differential pressure switch Models DC, DCC

Compact differential pressure switch Models DC, DCC Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes

More information