Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en
|
|
- Teresa Warren
- 5 years ago
- Views:
Transcription
1 00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable for low power consumption in non hazardous areas without barrier Solenoid: ATEX category II GD, type of protection Ex ia IIC T/T6, EX td A IP66 T9 C, suitable for zones, (gases) and, (dusts) Working from 0 bar up High operational reliability even after long periods of inoperation Suitable for control and instrument quality air Also suitable for open air installation NAMUR FLANGE: With integrated exhaust air recirculation DIN EN 68 IEC 68 up to SIL Approval depends on magnetic system, see page! Technical features Medium: Compressed air, filtered, nonlubricated and dry Other fluids on request Operation: Direct solenoid operated poppet valves Flow direction: Optional Mounting position: Any, but preferably with solenoid vertical Port size:, / NPT or flanged with NAMUR Interface Operating pressure: bar Fluid/Ambient temperature: C Depending on solenoid system Air supply must be dry enough to avoid ice formation at temperatures below + C. For outdoor installation please protect all connections against the penetration of moisture! Materials: Housing: brass.00 (Ms 8), stainless steel.0 (6 L) hard-anodised aluminium.06 Internal parts: stainless steel, brass Solenoid housing: aluminium, anodized hartanodisiert.06 Seals: NBR Technical data Symbol Port size Operating *) kv-wert Material Weight without Dimension Model pressure (bar) (Cv (US) kv x, Seat Housing solenoid (kg) No NBR Brass 0, / NPT NBR Brass 0, NBR Stainless steel 0, / NPT NBR Stainless steel 0, NAMUR NBR Aluminium*) 0, / NPT NAMUR NBR Aluminium*) 0, NAMUR *) NBR Aluminium*) 0, *) With gaseous and liquid fluids up to 0 mm /s *) Hard-anodised *) P port in flange interface Note: At an ambient temperature of -0 C, higher air consumption may be experienced for short periods. / N/en..09.0
2 00 Solenoid parameters for use in intrinsically safe circuits Symbol Switch-on Allowed current max. current min. Pick-up delay typical *) (s) Protection class Temperature Ambient/Fluid ( C) Weight (kg) Model approx. 0,... IIG Ex ia IIC T6 IIG Ex ia IIC T IID IP66 T9 C ,8 00 *) depending on intrinsical current supply Solenoid parameters for use in non harardous locations Symbol Switch-on Allowed current max. current min.... 6, 7 0,8 at V Power consumption (W) Pick-up delay typical *) (s) Protection class Temperature Ambient/Fluid ( C) Weight Model (kg) 0,... s IP ,8 00 *) depending on intrinsical current supply Accessories Silencer *) Exhaust guard *) Throttle control plate Flange plate Yoke M/S (G/) 06 (G/, / NPT) 009 (for G/ only) (NAMUR single connection plate, for G/ only) 009 C/S (/ NPT) *) For indoors use only *) For outdoor use Page 0679 (NAMUR-rip use in combination with 06790, Alu) Operating sequence 8 V V ma Supply V 0 V Off Charging process Off Current process Off Valve operation status Off Current supply units: Intrinsically safe power supply units can be choosen in a list of compatibility in When selecting an intrinsically safe power supply, it is important to observe the maximum permissible values acc. to the EC-Type-Examination Certificate PTB 0 ATEX 00 respectively IECEx PTB Ui 8 V, LI 0 ma, Pi, W The effective internal capacities Ci; and inductivities Li of the solenoid are negligibly low. Function of solenoid drive To switch the direct operated valve, a certain energy is required. This energy is stored in a condenser. The charging is V. The higher the supply, the shorter the charging time. As soon as the charging has been reached, the valve switches. The small current now flowing through the coil is sufficient to hold the valve in the open position. At least 0 ma are required for this. N/en /
3 00 Dimensions Valves 70, , 0 7, M ø0 M M0 x, 9 70, For port size see general information mm deep 0 7, M, 7, ø ø,,, 6 7, 7, ø ø,,,, 6 7 / N/en..09.0
4 00 Circuit diagram NAMUR hole pattern (driving side) M Port (A) Coding stud threaded M (0 deep) Port (R) NAMUR quick exhaust module for a better kv-value by exhaust see data sheet..80 NAMUR interlinking plates in redundancy design for»safety exhausting«and»safety ventilating«see data sheet..80 Single connection plate Model: NAMUR slot Model: 0679 M (x), 0 ø 9, , 6 9, ø 60 ø 9 ø, 7 N/en /
5 00 Yoke Model: 009 Throttle control plate Model: x, 0 Silencer Model: M/S, C/S Exhaust guard Model: 06, 8 0 ø / ø / M , M B B A A Warning These products are intended for use in industrial compressed air and fluid systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. / N/en..09.0
Material pressure (bar) (Cv (US) kv x 1,2 Seat
00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve
More informationNAMUR FLANGE: With integrated exhaust air recirculation Ordering information
00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled
More information24010, 3/2 Direct solenoid actuated poppet valve
00, / > / (G or NPT) Inline & NAMUR > Main application: Single acting actuators in intrinsically safe circuits > Approval according to IEC 68, multichannel up to SIL > Solenoid valve with low power consumption
More information97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface
9700 NAMUR / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, NAMUR Interface For single and double acting actuators / or / way function in one valve Easily interchangeable
More informationV82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components
More information26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves
60, 8007 NAMUR / & / > > Port size: G/ and NAMUR interface > > Easily interchangeable solenoid system > > For single and double operated actuators > > Standard manual override with detent > > Maintenance-free
More information98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR/INLINE / way poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators TÜV-approval based on type examination
More information97100 NAMUR. Technical data
9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators
More information97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT
97 Inline /, 5/ & 5/ spool valves electromagnetic actuated, indirectly controlled G /, / NPT For single and double operated actuators Crossover-free switching, switch-over function guaranteed even with
More informationOperating pressure (bar) kv factor (m 3 /h) *3)
/ poppet valves (stainless steel) electromagnetic actuated, directly controlled G /8, G /4 or /4 NPT Working from 0 bar up Assembled free of oil and grease Suited for fine vacuum down to,33 0 - mbar For
More information97105 Inline. Ordering information. Technical data. Accessories See page 5
75 Inline /-, 5/- and 5/ directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves G /, / NPT, G /, / NPT For single and double operated actuators Crossover-free switching,
More informationHERION SERIES Indirect solenoid actuated soft seal
HERION 9700 SERIES Indirect solenoid actuated soft seal spool valves with NAMUR interface /, 5/ - G/ For single and double acting actuators Crossover-free switching, switchover function guaranteed even
More informationFlow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en
/ poppet valves electromagnetic actuated, directly controlled G /4, G / or /4 NPT Working from 0 bar up Short switching times Suited for fine vacuum down to,33 0 - mbar For a.c. solenoid systems with integrated
More informationFor single and double operated actuators. Exhaust air recirculation (3/2 way function)
For single and double operated actuators /-, 5/- and 5/ Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4 or /4 NPT NAMUR interface Exhaust
More informationOur policy is one of continued research and development. We therefore reserve the right
For single and double operated actuators 3/2-, 5/2- and 5/3 Directional Control Valves Actuation: Electromagnetic Indirectly controlled soft seal spool valves Connection G /4, /4 NPT NAMUR Interface Exhaust
More informationOur policy is one of continued research and development. We therefore reserve the right
970 Namur /-, /- and /-Directional control valves Electromagnetic indirectly controlled soft seal spool valves G /4, /4 NPT NAMUR-interface For single and double operated actuators Exhaust air recirculation
More information26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.
60, 60, 8007 For single- and double-acting drives /, / and / Directional Control Valves Modular NAMUR design Actuation: Electromagnetic Indirectly controlled spool valves Connections G /8, G /, / NPT Standard
More information3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface
3/ Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface Suitable for instrumental air, neutral gaseous and liquid fluids and
More information2oo2 with bypass valve exhaust guards and indicators. 2oo2 I4. N/en
V8 series Redundant valve manifold systems - Modular with bypass oo Safety, oo Availability and oo Safety and Availability Modular design - Maxseal valves ypass function enables valve removal online Stainless
More informationFlow direction: Fixed. G1/4, G1/2 NAMUR G1/ Aluminium xxxx***** G1/4, G1/2 NAMUR G1/ Stainless steel xxxx*****
HERION 9805 SERIES Indirect solenoid actuated poppet valves with NMUR interface / - Internal thread G/, / NPT or flanged Main application: single operated actuators TÜV-approval based on IE 6 508,DIN V
More informationFor double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring
For double-acting actuators 5/ Directional Control Valves Actuation: Electromagnetic Indirect solenoid operation soft seal spool valve Connections G 1/, 1/ NPT, G 1/, NAMUR Interface Crossover-free switching
More informationICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated
ICOS - /, / or 5/ Exia poppet valves > > Port size: /... / (ISO G/NPT) /... (Flanged) > > Zone 0, Exia solenoid pilot operated valve > > Safety integrity level and > > Reliable and long life, ideal for
More information25000, 4/2 Direct solenoid actuated poppet valves
> > Port size: /4, /2 > > Working from 0 bar up > > Suited for outdoor installation > > Suitable for vacuum range down.33 0-2 mbar l/s > > : 65, Ex em, Ex d TEX approved (see solenoid table) Technical
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationHigh pressure valves. 80 to 350 bar
80 to 350 bar High switchable p Hermetically sealed poppet valves Excellent repeatability of switching times Function even with lager voltage tolerance Compact design DN to DN 40 Technical data Medium:
More informationHydraulic pressure switch 20D Acc. to ATEX
Acc. to ATEX 5 to 400 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More information3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for
More informationT 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators
T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and
More informationFunction. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4
Working from 0 bar up Short switching times Suited for fine vacuum down to 1,33 10-3 mbar Assembled oil and grease-free For a.c. solenoid systems with integrated rectifier (40 to 60 Hz) These solenoid
More informationVersions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve
Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE
More informationSuper X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated
> > Port size: G/8 & G/4 > > Low and high power solenoid coil options > > End, side or face mounting solenoids > > Light weight corrosion resistant materials > > Option for manual override acting directly
More information-V- New. Valve series VOFC. 2009/08 Subject to change Internet:
Valve series VOFC 2009/08 Subject to change Internet: www.festo.com/catalogue/... 159 Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way
More informationLimit Switch Type 4747
Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical
More informationDirect-acting 3/2 way plunger valve
Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type
More information3 (R) 1 (P) 5 (S) Port size 1 (P) 2 (A) 3 (R) 4 (B) 5 (S)
XSz 8V & XSz 0V 5/ directional control valve with dynamic monitoring For mechanical presses and other safety applications G/4, G/, /4 NPT & / NPT Inherently fail-safe without residual pressure Dynamic
More informationVP23 3-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G 1/4... G 3/4
-way proportional pressure control valve Directly-controlled seat valve with µp-driven pressure control G /... G / All-digital control electronics Variable pressure control Optional: serial interface with
More informationSolenoid Valve Island Type 3965
Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and
More informationEngineering GREAT Solutions
Engineering GREAT Solutions Process Express Precision. Engineered. Through our people, products and service. Contents 1 2 3 4 5 6 VALVES I/P & E/P CONVERTERS PRESSURE SWITCHES & SENSORS AIR PREPARATION
More informationAllfluid pressure switches 20D to ATEX
-1... 63 bar For Ex zones 1 and 2 (gases) as well as Ex zones 21 and (dusts) category II2G, type of protection EEx de IIC T6 Microswitch with gold plated contacts Electrical connection: connector M20 x
More information5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO #1, #2, #3, #4 Steel reinforced main seals
5/2 and 5/3 Valves Solenoid and Pilot Actuated Sub-base Mounted ISO 5599- #, #2, #3, #4 Steel reinforced main seals 6 bar and 0 bar CNOMO solenoid pilots with locking or non-locking manual override Low
More informationElectronic Limit Switch Type
Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.
More informationThe extendable type 5470 EExi can be used for block modules or for entire valve blocks (tag connectors on top, coil spacing 19 mm).
/2- and 4/2-multi-way valves ; servo-assisted; block assembly or NAMUR flange; DN 4; flow rate: 00 l/min Advantages / Benefits II 2G EEx ia IIC T6 PTB0 ATEX 275 approved Available for block assembly and
More informationSPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)
SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, / 0 0 /-/ Série FEATURES The monostable spool valves have TÜV certified IEC 608 Functional
More informationWeight (kg) Model L92C- P-ETN. N/en
Excelon Pro Lubricator - Oil Fog ø 6... mm, G /8... G /8 Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air Operating pressure:
More informationMFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS
Solenoid coils Solenoid coils Product range overview Version Type For valve series Page/ Internet MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS F solenoid coil MSF VACF 3 N solenoid coil VACN-N 6 N
More informationT84T - Excelon Plus Modular System 3/2 shut-off valve
> Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > 3/2 way function > Threaded exhaust port > Lockable in closed
More informationNugget 40, V08 series
Nugget 0, V0 series Integrally ported 5/ and 5/3 Spool valves Solenoid actuated and pilot operated Ø, Ø mm or High flow from mm body width Wide range of voltages available Low profile fixed length manifolds
More informationSPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4
SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 4 2 5 4 2 5 4 2 5 4 2 5 5/2 Series 55 FEATURES The monostable spool valves have TÜV certified
More informationI 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I
I 6A 2-pole up to 50 V I I 6A 3-pole up to 50 V I Flange socket Coupler Technical data Ex-plugs and receptacles for low voltage, 2- and 3-pole acc. to IEC 60309-/2 Marking accd. to 94/9/EC II 2 G Ex de
More informationDrain. Technical data, standard model, shut off valve, filter/regulator with exhaust port and lubricator. Element
BL9 Excelon Pro Combination unit Filter/Regulator and Lubricator ø mm, G / Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air
More informationSolenoid Valves Type 3963
Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate
More informationSPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4
SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 NC 0 0 / Series 55 FEATURES The monostable spool valves have TÜV certified IEC 6508
More informationSystem 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter
System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter Application Used to convert a direct-current input signal into a pneumatic output signal for measuring and control
More informationSPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot
SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 044 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000 racket
More informationVP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control
VP, -way proportional pressure control valves > > Port size: G/... G/ > > All-digital control electronics > > Variable pressure control > > Optional: serial interface with VP-Tool Software > > Optional
More information9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,
E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist
More informationATEX Compliant 5 Port Solenoid Valve II 2G Ex ia IIC T6 Gb Ta 10 C to 45 C. How to order. Barrier. Electrical entry
TEX Compliant Port Solenoid Valve Series 2-SY II 2G Ex ia IIC T4...T Gb Ta 10 C to 0 C 44 II 2G Ex ia IIC T6 Gb Ta 10 C to 4 C How to order 2 SY 1 2 0 01 F TEX category 2 7 9 Series 2-SY000 2-SY7000 2-SY9000
More informationI Ex-control stations I
Type 11 83 Type 11 82 Type 11 81 Technical data Ex-control stations Type 11 81 I Type 11 82 I Type 11 83 Marking accd. to 9/9/EC II 2 G Ex ed ib m IIC T6 II 2 D Ex td A21 IP66 T80 C EC-Type Examination
More informationPHOENIX CONTACT - 01/2008
Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It
More informationType Electronic Limit Switch
Type 3738-20 Electronic Limit Switch With optional solenoid valve Application Electronic limit switch for on/off applications to indicate the end position. Optionally with integrated solenoid valve. Special
More informationK Series 3 Way Direct Acting Balanced Poppet Solenoid Valve
Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS
More informationMN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142
Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationN/** поставка оборудования для подготовки воздуха
M/0000 Series Inline /, 5/ and 5/ Spool Valves Solenoid and Pilot Actuated G / Low power solenoids High flow Unique steel reinforced seals Light weight corrosion resistant materials Technical Data Medium:
More informationV03, V04, V05 (EXCEL 32) 2/2 & 3/2 Direct solenoid actuated poppet valves
V0, V0, V05 (EXCEL ) / & / > > Port size: G/8, G/ > > Extensive range of power and orifice size options > > Choice of manual override > > Compact installation > > Removeable coil > > Standard exhaust diffuser
More informationElectro-pneumatic control valves
Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve
More informationDrain. Element. Flow (dm 3 /s) * B92 - K- T1-RMG. N/en
BG, BB Excelon Pro General Purpose filter/regulator ø... mm, G /...G / Configuration flexibility Excellent value Low weight No tools required for assembly Technical features Medium: Compressed air Operating
More informationSeries 20 D. Pressure switches for all-fluid technique Port sizes G 1 /4 and G 1 /2
Series 0 D Pressure switches for all-fluid technique Port sizes and Microswitch with gold-plated contacts (silver plated for outdoor variants) Plug-in connection to DIN 4650 Technical Data Fluid: Neutral
More informationLRA/8000/M/EX, LRA/8000/EX, ISO cylinder Magnetic & Non-magnetic piston, double acting
> > Ø 32... 320 mm > > Comprehensive range for the utmost versatility > > Wide temperature range > > Supplied complete with piston rod locknut > > Conforms to ISO 15552 (ISO 6431, VDM 24562 and NFE 49-003-1)
More informationPneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767
Pneumatic Positioner Type 3766 Electropneumatic Positioner Type 3767 Application Single-acting or double-acting positioners for attachment to pneumatic control valves. Supplied with a pneumatic input signal
More information2/2 Pressure operated valves
Operation Series Page no. Function 2/2 3/2 Body material Stainless steel Brass Solenoids IP Protection class IP65 (with connector) Explosion proof class Zones 1, 21 II 2 GD EEx m IP67 II 2 G EEx me IP54
More information/2-way piston valves
> > ort size: DN 15... 100 Flange connection, ressure rating N 40 > > Valve operates without differential pressure (Zero delta ) > > Suitable for vacuum > > djustable: Damped operation () > > Valve piston
More information/2-way piston valves
> > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring
More informationBL68 - Olympian Plus plug-in system Filter/regulators and lubricators
> > Port size: 3/4... /2 (ISO G/ PTF) > > Complete air processing units pre-assembled, ready to install Technical features Medium: Compressed air only Maximum operating pressure: 7 bar (246 psi) Pressure
More informationMN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142
3/2-way Technical data for series Order code -310-HN-142 Series and function Standard coil 1) (with plug socket 28-ST-01) 141 = 12 V DC, 4.2 W 142 = 24 V DC, 4.2 W 152 = 24 V AC, 7/4 VA 156 = 115 V AC,
More informationCompact differential pressure switch Models DC, DCC
Mechatronic pressure measurement Compact differential pressure switch Models DC, DCC WIKA data sheet PV 35.40 Process Compact Series Applications Differential pressure monitoring and control of processes
More informationSolenoid coils VACF Type codes
Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,
More informationCapacitive level sensors CLS 23
For level detection of electrically conductive and non-conductive liquids Compact miniature performance for direct mounting to vessels, tanks, sumps and tubes Easy setting by means of magnetic pen SIL
More informationApplication The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.
DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential
More informationSpecial valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.
Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx
More information% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT
4 Air and Inert Gas Intrinsically Safe Valves Brass, Aluminum, or Stainless Steel Bodies /4" to " NPT / 3/ 4/ 5/ 5/3 Features Intrinsically safe solenoid enclosures to provide corrosion resistance in harsh
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and
More informationType 4746 Electric or Pneumatic Limit Switch
Type 4746 Electric or Pneumatic Limit Switch Application Limit switches with inductive, electric or pneumatic contacts for attachment to pneumatic or electric control valves, to Type 4763 Electropneumatic
More informationSystem Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters
System 6000 Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters Edition April 2018 Information Sheet T 6000 EN Electropneumatic Converters i/p converters
More informationSBM TECHNOLOGY Cooling / Air Recovery Valve
SBM TECHNOLOGY Cooling / Air Recovery Valve Part no. VSP15203x Advanced high pressure seal technology Integrated non-return valve Robust, compact & lightweight design Proven & reliable technology Maintenance
More informationWeight (kg) Dimension No. G1/4 Exhausting None 0,2 1 T F2BG *1) Interface Exhausting None 0,4 3 T10-N10-D2BN
T > > Port size: / or interface version > > Low operating forces > > High durability > > Easy installation, simple operation and maintenance free > > Full bore passage to maximise flow rate > > Wide pressure
More informationBody: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)
Parker Lucifer Data Sheet 22062004 General information Lucifer ref.: 341N31 Global ref.: 7341NAKBJNM0 Housing ref.: 2995 Coil ref.: 481865 Protection class: Assembly wt. (g): 510 Body: Seat disc: Anod.
More informationI Ex-Safety switches I
3-pole, 20 A Technical data Ex-Safety switch 20 A for variable-speed three-phase drives Marking to 94/9/EC II 2 G Ex ed ia IIC T6 / II 2 D Ex td A21 IP66 T80 C EC-Type Examination Certificate PTB 99 ATEX
More informationJUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram
Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It
More information3/2-way Rocker Solenoid Valve for pneumatic systems
3/-way Rocker Solenoid Valve for pneumatic systems EEx ia versions Direct-acting High cycling rate Reduced power consumption Type 6104 can be combined with... Sub-base connection Approvals: Type 654 Servo-assisted
More informationKämmer Actuators Series 4 Pneumatic and Electropneumatic
flowserve.com Kämmer Pneumatic and Electropneumatic Description Kämmer pneumatic actuators are widely known for their versatile diaphragm design, easy installation and simplified maintenance. When compared
More informationAUTO STAR with central connector M12x1
with central connector M2x Non corrosive spool and sleeve for long trouble free life 5/2 and Glandless Valves Actuated Sub-base Mounted ISO 5599- #, #2, #3 6 bar (4,5 W) and 0 bar (2 W) 24V DC solenoids
More information18D according to ATEX
Pneumatic ressure switch -... bar Hydraulic ressure switch 5... 4 bar For EX-alications according to ATEX 00 a: Zone 2 category ATEX 3G (gases) Zone 22 category ATEX 3D (dust) TÜV (technical insection
More informationOffshore and Onshore Applications Lucifer TM 2/2 and 3/2 ways 316L Stainless Steel solenoid valves
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding courtesy of Statoil Offshore and Onshore Applications Lucifer TM 2/2
More informationM/48, M/148. 3/2 Poppet Valves Electrically Actuated. Miniature, 22 mm normally closed and normally open models. Sub-base mounted and manifold mounted
M8, M Miniature, 22 mm normally closed and normally open models Sub-base mounted and manifold mounted 32 Poppet Valves Electrically Actuated M5 Manual override as standard Encapsulated coils with very
More informationMagnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)
Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications
More informationPilot operated solenoid valves for pneumatic actuators
Pilot solenoid valves for pneumatic actuators 3 / 2 and 5 / 2 way solenoid valves Orifice size 6 and 12 mm NAMUR and threaded connections Pressure range 0 (2) 8 bar For air and inert gases With TÜV-approval
More information