APPLICABILITY & EFFECTIVITY

Size: px
Start display at page:

Download "APPLICABILITY & EFFECTIVITY"

Transcription

1 NY Thermal Inc. Tel: (506) Tll Free: Fax: Web: Installatin Instructins & PrtNde Startup Guide RER and LER Gateway Interface fr Building Management Systems PrtNde - The RER and LER mdels are used fr interfacing applicable NY Thermal Bilers t the apprpriate autmated Building Management Systems. Failure t fllw instructins in the Startup Guide may result in equipment damage, prperty damage r persnal injury. Applicable NTI Biler Mdels: Lx , Tft60-399, FTG PrtNde RER PrtNde RER Kit Includes: PrtNde RER MdBus-BACnet-N2 Gateway (FPC-N ) PrtNde Startup Guide RER Building Autmatin Systems: BACnet MS/TP, BACnet/IP, Mdbus/TCP, Metasys N PrtNde LER PrtNde LER Kit Includes: PrtNde LER Mdbus-LnWrks Gateway (FPC-N ) PrtNde Startup Guide LER Building Autmatin Systems LnWrks APPLICABILITY & EFFECTIVITY Explains PrtNde FPC-N34 and FPC-N35 hardware and hw t install it. The instructins are effective fr the abve as f December S:\NTI2001_N_Drive ( )\R&D\BMS Interface\Prtnde\ instructins - PrtNde Startup Guide.dcx

2 A Quick Start Guide 1. Recrd the infrmatin abut the unit. (Sectin 2.1) 2. Set the device s Mdbus RTU serial settings (i.e. baud rate, parity, stp bits) and Mdbus Nde-ID fr each f the devices that will be cnnected t PrtNde FPC-N34 r FPC-N35. (Sectin 2.3) 3. PrtNde FPC-N34 units: Select the Field Prtcl (BACnet MS/TP, BACnet/IP, Mdbus TCP/IP r Metasys N2) n the S Bank Dip Switches. (Sectin 2.4.1) 4. Enable the PrtNde Aut Discvery mde n Dip Switch Bank S. (Sectin 2.4.2) 5. BACnet MS/TP (FPC-N34): Set the MAC Address n DIP Switch Bank A. (Sectin 2.5.1) 6. BACnet MS/TP r BACnet/IP (FPC-N34): Set the BACnet Device Instance. (Sectin 2.5.2) 7. Metasys N2 r Mdbus TCP/IP (FPC-N34): Set the Nde-ID. (Sectin 2.5.3) 8. BACnet MS/TP (FPC-N34): Set the BAUD rate f the BACnet MS/TP Field Prtcl n DIP Switch Bank B. (Sectin 2.5.4) 9. Cnnect PrtNde FPC-N34 s 3 pin RS-485 prt t the Field Prtcl cabling, r cnnect PrtNde FPC-N35 s 2 pin LnWrks prt t the Field Prtcl cabling. (Sectin 3.2) 10. Cnnect PrtNde s 6 pin RS-485 cnnectr t the Mdbus RS-485 netwrk that is cnnected t each f the devices. (Sectin 3.3) 11. Cnnect Pwer t PrtNde s 6 pin cnnectr. (Sectin 3.5) 12. When pwer is applied it will take abut 3 minutes fr all the devices t be discvered, and the cnfiguratin file t be built. Once Aut-Discvery is cmplete turn OFF the S3 DIP Switch t save the cnfiguratin settings. (Sectin 3.5.1) 13. BACnet/IP r Mdbus TCP/IP (FPC-N34): Use the PrtNde s embedded tl which is accessed with a brwser, referred t in this manual as the Web Cnfiguratr, t change the IP Address. N changes t the cnfiguratin file are necessary. (Sectin 4) 14. LnWrks (FPC-N35): The PrtNde must be cmmissined n the LnWrks Netwrk. This needs t be dne by the LnWrks administratr using a LnWrks Cmmissining tl. (Sectin 7) 2

3 Certificatins BTL MARK BACNET TESTING LABORATORY The BTL Mark n PrtNde is a symbl that indicates that a prduct has passed a series f rigrus tests cnducted by an independent labratry which verifies that the prduct crrectly implements the BACnet features claimed in the listing. The mark is a symbl f a high-quality BACnet prduct. G t fr mre infrmatin abut the BACnet Testing Labratry. Click here fr BACnet PIC Statement. LONMARK CERTIFICATION LnMark Internatinal is the recgnized authrity fr certificatin, educatin, and prmtin f interperability standards fr the benefit f manufacturers, integratrs and end users. LnMark Internatinal has develped extensive prduct certificatin standards and tests t prvide the integratr and user with cnfidence that prducts frm multiple manufacturers utilizing LnMark devices wrk tgether. Sierra Mnitr has mre LnMark Certified gateways than any ther gateway manufacturer, including the PrtCessr, PrtCarrier and PrtNde fr OEM applicatins and the full featured, cnfigurable gateways. 3

4 TABLE OF CONTENTS 1 Intrductin PrtNde Gateway BACnet/LnWrks Setup fr PrtCessr PrtNde FPC-N34/FPC-N Recrd Identificatin Data Pint Cunt Capacity and Registers per Device Cnfiguring Device Cmmunicatins Set Mdbus COM setting n all f the Devices cnnected t the PrtNde Set Mdbus RTU Nde-ID fr each f the Devices attached t the PrtNde Selecting the Desired Field Prtcl and Enabling Aut-Discvery Selecting Desired Field Prtcl Enabling Aut-Discvery BMS Netwrk Settings: MAC Address, Device Instance and Baud Rate BACnet MS/TP (FPC-N34): Setting the MAC Address fr BMS Netwrk BACnet MS/TP and BACnet/IP (FPC-N34): Setting the Device Instance Metasys N2 r Mdbus TCP/IP (FPC-N34): Setting the Nde-ID BACnet MS/TP (FPC-N34): Setting the Baud Rate fr BMS Netwrk Interfacing PrtNde t Devices PrtNde FPC-N34 and FPC-N35 Shwing Cnnectin Prts Device Cnnectins t PrtNde Biasing the Mdbus RS-485 Device Netwrk End f Line Terminatin Switch fr the Mdbus RS-485 Device Netwrk BACnet MS/TP r Metasys N2 (FPC-N34): Wiring Field Prt t RS-485 BMS Netwrk LnWrks (FPC-N35): Wiring Field Prt t LnWrks Netwrk Pwer-Up PrtNde Aut-Discvery: After Cmpletin Turn Off t Save Cnfiguratin BACnet/IP r Mdbus TCP/IP: Change the Prtnde IP Address Cnnect the PC t PrtNde via the Ethernet Prt BACnet/IP and Mdbus TCP/IP: Setting IP Address fr Field Netwrk BACnet MS/TP and BACnet/IP: Setting Nde_Offset t Assign Specific Device Instances Hw t Start the Installatin Over: Clearing Prfiles LnWrks (FPC-N35): Cmmissining PrtNde n a lnwrks Netwrk Cmmissining PrtNde FPC-N35 n a LnWrks Netwrk Instructins t Dwnlad XIF File frm PrtNde FPC-N35 Using Brwser CAS BACnet Explrer fr Validating PrtNde in the Field Dwnlading the CAS Explrer and Requesting an Activatin Key CAS BACnet Setup CAS BACnet MS/TP Setup CAS BACnet BACnet/IP Setup NTI Field Wiring Diagrams Tft-Lx PrtNde RS485 Wiring, Single S7999C (White Display) Tft-Lx PrtNde RS485 Wiring, Multiple S7999C (White Display) Tft-Lx PrtNde RS485 Wiring, S7999D (Black Display) Lx Cmmercial PrtNde RS485 Wiring, Single S7999C (White Display) Lx Cmmercial PrtNde RER RS485 Wiring, S7999D (Black Display) FTG PrtNde RER RS485 Wiring, S7999D (Black Display) Appendix A. Trubleshting Appendix A.1. Lst r Incrrect IP Address Appendix A.2. Viewing Diagnstic infrmatin Appendix A.3. Check Wiring and Settings Appendix A.4. Take Diagnstic Capture With the FieldServer Utilities Appendix A.5. BACnet: Setting Netwrk_Number fr mre than ne PrtNde n Subnet Appendix A.6. LED Diagnstics fr Cmmunicatins Between PrtNde and Devices

5 Appendix A.7. Passwrds Appendix B. Vendr Infrmatin NY Thermal Appendix B.1. Sla Mdbus RTU Mappings t BACnet, Metasys N2 and LnWrks Appendix C. A Bank DIP Switch Settings Appendix C.1. A Bank DIP Switch Settings Appendix D. Reference Appendix D.1. Specificatins Appendix D.1.1. Cmpliance with UL Regulatins Appendix E. Limited 2 Year Warranty LIST OF FIGURES Figure 1: PrtCessr Part Numbers... 7 Figure 2: Supprted Pint Cunt Capacity... 7 Figure 3: Mdbus Registers per Device... 7 Figure 4: Mdbus RTU COM Settings... 8 Figure 5: S Bank DIP Switches... 9 Figure 6: S3 DIP Switch setting fr Aut Discvering Devices Figure 7: MAC address DIP switches Figure 8: BMS Baud Rate DIP Switches Figure 9: BMS Baud Rate Figure 10: PrtNde BACnet FPC-N34 (upper) and PrtNde FPC-N35 (lwer) Figure 11: Pwer and RS-485 Cnnectins Figure 12: Mdbus RS-485 Biasing Switch n the PrtNde N34 (left) and PrtNde N35 (right) Figure 13: Mdbus RS-485 End-Of-Line Terminatin Switch n the PrtNde N34 (left) and Figure 14: Cnnectin frm PrtNde t RS-485 Field Netwrk Figure 15: RS-485 BMS Netwrk EOL Switch Figure 16: LnWrks Terminal Figure 17: Required current draw fr the PrtNde Figure 18: Pwer Cnnectins Figure 19: S3 DIP Switch setting fr Aut Discvering Devices Figure 20: Web Cnfiguratr Screen Figure 21: Changing IP Address via Web GUI Figure 22: Web Cnfiguratr screen with Active Prfiles Figure 23: LnWrks Service Pin Lcatin Figure 24: Sample f Fserver.XIF File Generated Figure 25: Dwnlading the CAS Explrer Figure 26: Requesting CAS Activatin Key Figure 27: Tft-Lx PrtNde RS485 Wiring, Single S7999C (White Display) Figure 28: Tft-Lx PrtNde RS485 Wiring, Multiple S7999C (White Display) Figure 29: Tft-Lx PrtNde RS485 Wiring, S7999D (Black Display) Figure 30: Lx Cmmercial PrtNde RS485 Wiring, Single S6999C (White Display) Figure 31: Lx Cmmercial PrtNde RER RS485 Wiring, S7999D (Black Display) Figure 32: FTG PrtNde RER RS485 Wiring, S7999D (Black Display) Figure 33: Ethernet Prt Lcatin Figure 34: Errr messages screen Figure 35: Ethernet Prt Lcatin Figure 36: Web Cnfiguratr Setting Netwrk Number fr BACnet Figure 37: Diagnstic LEDs Figure 38: Specificatins

6 1 INTRODUCTION 1.1 PrtNde Gateway PrtNde is an external, high perfrmance Building Autmatin multi-prtcl gateway that is precnfigured t Aut-Discver any f NY Thermal s prducts (hereafter called device ) cnnected t the PrtNde and autmatically cnfigures them fr BACnet 1 MS/TP, BACnet/IP, Metasys 2 N2 by JCI, Mdbus TCP/IP r LnWrks 3. It is nt necessary t dwnlad any cnfiguratin files t supprt the required applicatins. The PrtNde is pre-laded with tested Prfiles/Cnfiguratins fr the supprted devices. 1 BACnet is a registered trademark f ASHRAE 2 Metasys is a registered trademark f Jhnsn Cntrls Inc. 3 LnWrks is a registered trademark f Echeln Crpratin 6

7 2 BACNET/LONWORKS SETUP FOR PROTOCESSOR PROTONODE FPC- N34/FPC-N Recrd Identificatin Data Each PrtNde has a unique part number lcated n the side r the back f the unit. This number shuld be recrded, as it may be required fr technical supprt. The numbers are as fllws: Mdel Part Number PrtNde N34 FPC-N PrtNde N35 FPC-N Figure 1: PrtCessr Part Numbers FPC-N34 units have the fllwing 3 prts: RS Ethernet + RS-485 FPC-N35 units have the fllwing 3 prts: LnWrks + Ethernet + RS Pint Cunt Capacity and Registers per Device The ttal number f Mdbus Registers presented by all f the devices attached t the PrtNde cannt exceed: Part number Ttal Registers FPC-N ,500 FPC-N ,500 Figure 2: Supprted Pint Cunt Capacity Devices Registers Per Device Sla 163 Figure 3: Mdbus Registers per Device 7

8 2.3 Cnfiguring Device Cmmunicatins Set Mdbus COM setting n all f the Devices cnnected t the PrtNde All f the serial devices cnnected t PrtNde MUST have the same Baud Rate, Data Bits, Stp Bits, and Parity settings. Figure 4 specifies the device serial prt settings required t cmmunicate with the PrtNde. Serial Prt Setting Device Prtcl Mdbus RTU Baud Rate Parity Nne Data Bits 8 Stp Bits 1 Figure 4: Mdbus RTU COM Settings Set Mdbus RTU Nde-ID fr each f the Devices attached t the PrtNde Set Mdbus Nde-ID fr each f the devices attached t PrtNde. The Mdbus Nde-ID s need t be uniquely assigned between 1 and 255. The Mdbus Nde-ID that is assigned fr each device needs t be dcumented The Mdbus Nde-ID s assigned are used fr designating the Device Instance fr BACnet/IP and BACnet MS/TP (Sectin 2.5.2) The Metasys N2 and Mdbus TCP/IP Nde-ID will be set t same value as the Nde-ID f the Mdbus RTU device. 8

9 2.4 Selecting the Desired Field Prtcl and Enabling Aut-Discvery Selecting Desired Field Prtcl PrtNde FPC-N34 units use the S bank f DIP switches (S0 S2) t select the Field Prtcl. See the table in Figure 5 fr the switch settings t select BACnet MS/TP, BACnet/IP, Mdbus TCP/IP, r Metasys N2 The OFF psitin is when the DIP switches are set clsest t the utside f the bx PrtNde FPC-N35 units d nt use the S bank DIP switches (S0 S2) t select a Field Prtcl. On PrtNde FPC-N35 units, these switches are disabled; the Field Prtcl is always LnWrks On PrtNde FPC-N35 units, there is n need t select prfiles fr Celsius r Fahrenheit S0 S3 DIP Switches S Bank DIP Switch Lcatin PrtNde FPC-N34 S Bank DIP Switches Prfile S0 S1 S2 BACnet/IP Deg F Off Off Off BACnet MS/TP Deg F On Off Off Metasys N2 Deg F Off On Off Mdbus TCP/IP On On Off BACnet/IP Deg C Off Off On BACnet MS/TP Deg C On Off On Metasys N2 Deg C Off On On BACnet MS/TP, BACnet/IP, Mdbus TCP/IP, and Metasys N2 Settings fr PrtNde FPC-N34 (BACnet) Figure 5: S Bank DIP Switches 9

10 2.4.2 Enabling Aut-Discvery NOTE: If Mdbus TCP/IP was selected in Sectin fr the Field/BMS prtcl, skip this sectin. Aut-Discvery is NOT used fr Mdbus TCP/IP. The S3 DIP switch is used t bth enable Aut-Discvery f knwn devices attached t the PrtNde, and t save the recently discvered cnfiguratin. See the table in Figure 6 fr the switch setting t enable Aut-Discvery If the PrtNde is being installed fr the first time, set S3 t the ON psitin t enable Aut-Discvery The ON psitin is when the DIP switches are set clsest t the inside f the bx S3 DIP Switch Aut-Discvery Mde S3 Aut-Discvery ON Build New Cnfiguratin On Aut-Discver OFF Save Current Cnfiguratin Off Figure 6: S3 DIP Switch setting fr Aut Discvering Devices 10

11 2.5 BMS Netwrk Settings: MAC Address, Device Instance and Baud Rate BACnet MS/TP (FPC-N34): Setting the MAC Address fr BMS Netwrk Only 1 MAC address is set fr PrtNde regardless f hw many devices are cnnected t PrtNde. Set the BACnet MS/TP MAC addresses f the PrtNde t a value between 1 t 127 (MAC Master Addresses); this is s that the BMS Frnt End can find the PrtNde via BACnet aut discvery. NOTE: Never set a BACnet MS/TP MAC Address frm 128 t 255. Addresses frm 128 t 255 are Slave Addresses and can nt be discvered by BMS Frnt Ends that supprt aut discvery f BACnet MS/TP devices. Set A bank DIP switches A0 A7 t assign a MAC Address t the PrtNde fr BACnet MS/TP. Please refer t Appendix C.1 fr the cmplete range f MAC Addresses and DIP switch settings. Figure 7: MAC address DIP switches NOTE: When setting DIP Switches, please ensure that pwer t the bard is OFF. 11

12 2.5.2 BACnet MS/TP and BACnet/IP (FPC-N34): Setting the Device Instance The BACnet Device Instances will be calculated by adding the Nde_Offset (default value is 50,000) t the device s Mdbus Nde ID (that was assigned in Sectin 2.3.2). The BACnet Device Instance can range frm 1 t 4,194,303. T assign specific Device Instance values, change the Nde_Offset value. (Sectin 2.3.2) Fr example: Nde_Offset value (default) = 50,000 Device 1 has a Mdbus Nde-ID f 1 Device 2 has a Mdbus Nde-ID f 22 Device 3 has a Mdbus Nde-ID f 33 Given that: Device Instance = Nde_Offset + Mdbus Nde_ID Device Instance, Device 1 = 50, = 50,001 Device Instance, Device 2 = 50, = 50,022 Device Instance, Device 3 = 50, = 50, BACnet MS/TP r BACnet/IP: Assigning Specific Device Instances With the default Nde_Offset value f 50,000 the Device Instances values generated will be within the range f 50,001 t 50,127. The values allwed fr a BACnet Device Instance can range frm 1 t 4,194,303. T assign a specific Device Instance (r range), change the Nde_Offset value. Methds fr changing the Nde_Offset value are prvided in Sectin 5. This step cannt be perfrmed until after the unit is cnnected and pwered Metasys N2 r Mdbus TCP/IP (FPC-N34): Setting the Nde-ID The Mdbus RTU Nde-ID s assigned t the devices attached t the PrtNde in Sectin will be the Metasy N2 r Mdbus TCP/IP Nde-ID s t the field prtcls. Metasys N2 and Mdbus TCP/IP Nde-ID Addressing: Metasys N2 and Mdbus TCP/IP Nde-ID s range frm

13 2.5.4 BACnet MS/TP (FPC-N34): Setting the Baud Rate fr BMS Netwrk B bank DIP switches B0 B3 can be used t set the Field baud rate f the PrtNde t match the baud rate required by the Building Management System fr BACnet MS/TP. The baud rate n PrtNde fr Metasys N2 is set fr B bank DIP switches B0 B3 are disabled fr Metasys N2 n PrtNde FPC-N34. B bank DIP switches B0 B3 are disabled n PrtNde FPC-N35 (FPC-N35 LnWrks). Figure 8: BMS Baud Rate DIP Switches Baud Rate DIP Switch Selectin Baud B0 B1 B2 B On On On Off Off Off Off On 38400* On On Off On Off Off On On On Off On On Figure 9: BMS Baud Rate * Factry default setting = 38,400 13

14 Installatin Instructins 3 INTERFACING PROTONODE TO DEVICES 3.1 PrtNde FPC-N34 and FPC-N35 Shwing Cnnectin Prts Figure 10: PrtNde BACnet FPC-N34 (upper) and PrtNde FPC-N35 (lwer) 14

15 3.2 Device Cnnectins t PrtNde PrtNde 6 Pin Phenix cnnectr fr RS-485 Devices The 6 pin Phenix cnnectr is the same fr PrtNde FPC-N34 (BACnet) and FPC-N35 (LnWrks). Pins 1 thrugh 3 are fr Mdbus RS-485 devices. The RS-485 GND (Pin 3) is nt typically cnnected Pins 4 thrugh 6 are fr pwer. D nt cnnect pwer wait until Sectin 3.5. Device Pins PrtNde Pin # Pin assignment Pin RS Pin 1 RS Pin RS Pin 2 RS Pin GND Pin 3 RS-485 GND Pwer In (+) Pin 4 V + Pwer In (-) Pin 5 V - Frame Grund Pin 6 FRAME GND Figure 11: Pwer and RS-485 Cnnectins 15

16 3.2.1 Biasing the Mdbus RS-485 Device Netwrk An RS-485 netwrk with mre than ne device needs t have biasing t ensure prper cmmunicatin. The biasing nly needs t be dne n ne device. The PrtNde has 510 Ohm resistrs that can be used t set the biasing. The PrtNde s default psitins frm the factry fr the Biasing jumpers are OFF. The OFF psitin is when the 2 RED biasing jumpers straddle the 4 pins clsest t the utside f the bard f the PrtNde. (Errr! Reference surce nt fund.) Only turn biasing ON: IF the BMS cannt see mre than ne device cnnected t the PrtNde AND all the settings (Mdbus COM settings, wiring, and DIP switches) have been checked T turn biasing ON, mve the 2 RED biasing jumpers t straddle the 4 pins clsest t the inside f the bard f the PrtNde. RS-485 Bias Switch (ff) Figure 12: Mdbus RS-485 Biasing Switch n the PrtNde N34 (left) and PrtNde N35 (right) 16

17 3.2.2 End f Line Terminatin Switch fr the Mdbus RS-485 Device Netwrk On lng RS-485 cabling runs, the RS-485 trunk must be prperly terminated at each end. The PrtNde has an End Of Line (EOL) blue jumper. The default setting fr this Blue EOL switch is OFF with the jumper straddling the pins clsest t the inside f the bard f the PrtNde. On shrt cabling runs the EOL switch des nt t need t be turned ON If the PrtNde is placed at ne f the ends f the trunk, set the blue EOL jumper t the ON psitin straddling the pins clsest t the utside f the bard f the PrtNde. Always leave the single Red Jumper in the A psitin (default factry setting). Mdbus RS-485 EOL Switch (ff) Leave in A Psitin Figure 13: Mdbus RS-485 End-Of-Line Terminatin Switch n the PrtNde N34 (left) and PrtNde N35 (right) 17

18 3.3 BACnet MS/TP r Metasys N2 (FPC-N34): Wiring Field Prt t RS-485 BMS Netwrk Cnnect the BACnet MS/TP r Metasys N2 RS-485 netwrk wires t the 3-pin RS-485 cnnectr n PrtNde FPC-N34. (Figure 14) The RS-485 GND (Pin 3) is nt typically cnnected See Sectin 5 fr infrmatin n cnnecting t BACnet/IP netwrk. If the PrtNde is the last device n the BACnet MS/TP r Metasys N2 trunk, then the End-Of-Line Terminatin Switch needs t be enabled. (Figure 15) The default setting frm the factry is OFF (switch psitin = right side) T enable the EOL Terminatin, turn the EOL switch ON (switch psitin = left side) BMS RS- 485 Wiring PrtNde Pin # Pin Assignment RS Pin 1 RS RS Pin 2 RS Pin 3 RS-485 GND + - G Figure 14: Cnnectin frm PrtNde t RS-485 Field Netwrk End-f-Line Switch Figure 15: RS-485 BMS Netwrk EOL Switch 3.4 LnWrks (FPC-N35): Wiring Field Prt t LnWrks Netwrk Cnnect PrtNde t the field netwrk with the LnWrks terminal using a twisted pair nnshielded cable. LnWrks has n plarity. Figure 16: LnWrks Terminal 18

19 3.5 Pwer-Up PrtNde Apply pwer t PrtNde as shw belw in Figure 18. Ensure that the pwer supply used cmplies with the specificatins prvided in Appendix D.1. PrtNde accepts either 9-30VDC r VAC n pins 4 and 5. Frame GND shuld be cnnected. Pwer Requirement fr PrtNde External Gateway Current Draw Type PrtNde Family 12VDC/VAC 24VDC/VAC 30VDC FPC N34 (Typical) 170mA 100mA 80mA FPC N34 (Maximum) 240mA 140mA 100mA FPC N35 (Typical) 210mA 130mA 90mA FPC N35 (Maximum) 250mA 170mA 110mA NOTE: These values are nminal and a safety margin shuld be added t the pwer supply f the hst system. A safety margin f 25% is recmmended. Figure 17: Required current draw fr the PrtNde Pwer t PrtNde PrtNde Pin # Pin Assignment Pwer In (+) Pin 4 V + Pwer In (-) Pin 5 V - Frame Grund Pin 6 FRAME GND Figure 18: Pwer Cnnectins Aut-Discvery: After Cmpletin Turn Off t Save Cnfiguratin NOTE: If Mdbus TCP/IP was selected in Sectin fr the Field/BMS prtcl, skip this sectin. Aut-Discvery is NOT used fr Mdbus TCP/IP. The S3 DIP Switch fr Enabling Aut-Discvery shuld have been set in Sectin befre applying pwer t the PrtNde. D nt Enable Aut-Discvery when the unit is pwered. 19

20 When pwer is applied t a PrtNde that is set t Enable Aut-Discvery, it will take 3 minutes t cmplete the discvery f all f the RS-485 devices attached t the PrtNde. Once the PrtNde has discvered all f the RS-485 devices, set the S3 DIP switch t the OFF psitin t save the current cnfiguratin. PrtNde FPC-N34 and FPC-N35 S3 DIP Switch Aut-Discvery Mde S3 Aut-Discvery ON Build New Cnfiguratin On Aut-Discver OFF Save Current Cnfiguratin Off Figure 19: S3 DIP Switch setting fr Aut Discvering Devices 20

21 4 BACNET/IP OR MODBUS TCP/IP: CHANGE THE PROTONODE IP ADDRESS 4.1 Cnnect the PC t PrtNde via the Ethernet Prt Cnnect a CAT5 Ethernet cable (Straight thrugh r Crss-Over) between the PC and PrtNde. The Default IP Address f PrtNde is , Subnet Mask is If the PC and PrtNde are n different IP Netwrks, assign a static IP Address t the PC n the xxx netwrk. G t > > Right-click n Lcal Area Cnnectin > Prperties Highlight > Select: Use the fllwing IP Address Click twice 21

22 4.2 BACnet/IP and Mdbus TCP/IP: Setting IP Address fr Field Netwrk After setting a lcal PC t be n the same subnet as the PrtNde (Sectin 4.1), pen a web brwser n the PC and enter the IP Address f the PrtNde; the default address is The Web Cnfiguratr will be displayed as the landing page. (Figure 20) NOTE: Belw the Active prfiles heading are listed the prfiles fr cnnected devices. If n prfiles are present, then the wiring, baud rate, and DIP switch settings must be checked, because there is a prblem with device cmmunicatins. All the active prfiles must shw the crrect Nde-ID s befre prceeding. NOTE: If multiple devices are cnnected t the PrtNde, set the BACnet Virtual Server Ndes field t Yes ; therwise leave the field n the default N setting. T access the Web GUI, click n the Diagnstics & Debugging buttn in the bttm right side f the page. Figure 20: Web Cnfiguratr Screen Frm the Web GUI s landing page, click n Setup t expand the navigatin tree. Then select Netwrk Settings t access the IP Settings menu. (Figure 21) 22

23 Figure 21: Changing IP Address via Web GUI Mdify the IP Address (N1 IP Address field) f the PrtNde Ethernet prt. If necessary, change the Netmask (N1 Netmask field). Type in a new Subnet Mask. If necessary, change the IP Gateway (Default Gateway field). Type in a new IP Gateway. NOTE: If the PrtNde is cnnected t a ruter, the IP Gateway f the PrtNde shuld be set t the IP Address f that ruter. Reset PrtNde. Unplug Ethernet cable frm PC and cnnect it t the netwrk hub r ruter. Recrd the IP Address assigned t the PrtNde fr future reference. 23

24 5 BACNET MS/TP AND BACNET/IP: SETTING NODE_OFFSET TO ASSIGN SPECIFIC DEVICE INSTANCES After setting a lcal PC t the same subnet as the PrtNde (Sectin 4.1), pen a web brwser n the PC and enter the IP Address f the PrtNde; the default address is If the IP Address f the PrtNde has been changed by previus cnfiguratin, the assigned IP Address will need t be btained frm the netwrk administratr. The Web Cnfiguratr will be displayed as the landing page. (Figure 22) Nde_Offset field will be presented displaying the current value (default = 50,000). Change the value f Nde_Offset t establish the desired Device Instance values, and click SUBMIT. Given that: Device Instance = Nde_Offset + Mdbus Nde_ID Then: Nde_Offset (required) = Device Instance (desired) Mdbus Nde_ID Fr example, if the desired Device Instance fr the 1 st device is 1,001: Device 1 has a Mdbus Nde-ID f 1 Device 2 has a Mdbus Nde-ID f 22 Device 3 has a Mdbus Nde-ID f 33 Nde_Offset (required) = 1,001 (Mdbus Nde_ID) = 1,001 1 = 1,000 NOTE: The Nde_Offset value will be applied t all devices. Device 1 Instance will then be = 1,000 + Mdbus Nde_ID = 1, = 1,001 Device 2 Instance will then be = 1,000 + Mdbus Nde_ID = 1, = 1,022 Device 3 Instance will then be = 1,000 + Mdbus Nde_ID = 1, = 1,033 Figure 22: Web Cnfiguratr screen with Active Prfiles 24

25 6 HOW TO START THE INSTALLATION OVER: CLEARING PROFILES After setting a lcal PC t the same subnet as the PrtNde (Sectin 4.1), pen a web brwser n the PC and enter the IP Address f the PrtNde; the default address is If the IP Address f the PrtNde has been changed by previus cnfiguratin, the assigned IP Address will need t be btained frm the netwrk administratr. The Web Cnfiguratr will be displayed as the landing page. At the bttm-left f the page, click the Clear Prfiles and Restart buttn. Once restart is cmplete, all past prfiles discvered and/r added via Web cnfiguratr are deleted. The unit can nw be reinstalled. 25

26 7 LONWORKS (FPC-N35): COMMISSIONING PROTONODE ON A LONWORKS NETWORK Cmmissining may nly be perfrmed by the LnWrks administratr. 7.1 Cmmissining PrtNde FPC-N35 n a LnWrks Netwrk The User will be prmpted by the LnWrks Administratr t hit the Service Pin n the PrtNde FPC-N35 at the crrect step f the Cmmissining prcess which is different fr each LnWrks Netwrk Management Tl. If an XIF file is required, see steps in Sectin t generate XIF. Figure 23: LnWrks Service Pin Lcatin Instructins t Dwnlad XIF File frm PrtNde FPC-N35 Using Brwser Cnnect a CAT5 Ethernet cable (Straight thrugh r Crss-Over) between the PC and PrtNde. The Default IP Address f PrtNde is , Subnet Mask is If the PC and PrtNde are n different IP Netwrks, assign a static IP Address t the PC n the xxx netwrk. Fr Windws XP: G t > > Right-click n Lcal Area Cnnectin > Prperties Highlight > Fr Windws 7: G t > > > > Right-click n Lcal Area Cnnectin > Prperties Highlight > 26

27 Fr Windws XP and Windws 7, select: Use the fllwing IP Address. Click twice. Open a web brwser and g t the fllwing address: [IP Address f PrtCessr]/fserver.xif. Example: /fserver.xif If the web brwser prmpts t save the file, save the file nt the lcal PC. If the web brwser displays the xif file as a web page, save the file nt the lcal PC as fserver.xif. Figure 24: Sample f Fserver.XIF File Generated 27

28 8 CAS BACNET EXPLORER FOR VALIDATING PROTONODE IN THE FIELD PrtCessr has arranged a cmplementary 2 week fully functinal cpy f CAS BACnet Explrer (thrugh Chipkin Autmatin) that can be used t validate BACnet MS/TP and/r BACnet/IP cmmunicatins f PrtNde in the field withut having t have the BMS Integratr n site. A serial r USB t RS-485 cnverter is needed t test BACnet MS/TP. 8.1 Dwnlading the CAS Explrer and Requesting an Activatin Key T request the cmplementary BACnet CAS key, g t and fill in all the infrmatin. Enter Vendr Cde NTI2BACnet. Once cmpleted, the address that was submitted will be registered. Figure 25: Dwnlading the CAS Explrer G t the fllwing web site, dwnlad and install the CAS BACnet Explrer t the lcal PC: Open CAS BACnet Explrer; in the CAS Activatin frm, enter the address that was registered and click n Request a key. The CAS key will then be ed t the registered address. Cut/paste key frm int the Prduct key field and click Activate. Figure 26: Requesting CAS Activatin Key 28

29 8.2 CAS BACnet Setup These are the instructins t set CAS Explrer up fr the first time n BACnet MS/ST and BACnet/IP CAS BACnet MS/TP Setup Using the serial r USB t RS-485 cnverter, cnnect it t the lcal PC and the 3 Pin BACnet MS/TP cnnectr n PrtNde FPC-N34. In CAS Explrer, d the fllwing: Click n settings Check the BACnet MS/TP bx and uncheck the BACnet/IP and BACnet Ethernet bxes Set the BACnet MS/TP MAC address t 0 Set the BACnet MS/TP Baud Rate t Click Ok On the bttm right-hand crner, make sure that the BACnet MS/TP bx is green Click n discver Check all 4 bxes Click Send CAS BACnet BACnet/IP Setup See Sectin 4.2 t set the IP Address and subnet f the PC that will be running the CAS Explrer. Cnnect a straight thrugh r crss Ethernet cable frm the PC t PrtNde. In CAS Explrer, d the fllwing: Click n settings Check the BACnet/IP bx and uncheck the BACnet MS/TP and BACnet Ethernet bxes In the Select a Netwrk Device bx, select the netwrk card f the PC Click Ok On the bttm right-hand crner, make sure that the BACnet/IP bx is green Click n discver Check all 4 bxes Click Send 29

30 9 NTI FIELD WIRING DIAGRAMS 9.1 Tft-Lx PrtNde RS485 Wiring, Single S7999C (White Display) Figure 27: Tft-Lx PrtNde RS485 Wiring, Single S7999C (White Display) 30

31 9.2 Tft-Lx PrtNde RS485 Wiring, Multiple S7999C (White Display) Figure 28: Tft-Lx PrtNde RS485 Wiring, Multiple S7999C (White Display) 31

32 9.3 Tft-Lx PrtNde RS485 Wiring, S7999D (Black Display) Figure 29: Tft-Lx PrtNde RS485 Wiring, S7999D (Black Display) 32

33 9.4 Lx Cmmercial PrtNde RS485 Wiring, Single S7999C (White Display) Figure 30: Lx Cmmercial PrtNde RS485 Wiring, Single S6999C (White Display) 33

34 9.5 Lx Cmmercial PrtNde RER RS485 Wiring, S7999D (Black Display) Figure 31: Lx Cmmercial PrtNde RER RS485 Wiring, S7999D (Black Display) 34

35 9.6 FTG PrtNde RER RS485 Wiring, S7999D (Black Display) Figure 32: FTG PrtNde RER RS485 Wiring, S7999D (Black Display) 35

36 Appendix A. Trubleshting Appendix A.1. Lst r Incrrect IP Address Ensure that FieldServer Tlbx is laded nt the lcal PC. If nt, dwnlad FieldServer- Tlbx.zip n the Sierra Mnitr webpage, under Custmer Care-Resurce Center, Sftware Dwnlads: Extract the executable file and cmplete the installatin. Ethernet Prt Figure 33: Ethernet Prt Lcatin Disable any wireless Ethernet adapters n the PC/Laptp. Disable firewall and virus prtectin sftware if pssible. Cnnect a standard CAT5 Ethernet cable between the PC and PrtNde. Duble click n the FS Tlbx Utility. Check IP Addresses frm the Device listings. Crrect IP Address(es) by right clicking the settings icn and changing the IP Address. 36

37 Appendix A.2. Viewing Diagnstic infrmatin Type the IP Address f the PrtNde int the web brwser r use the FieldServer Tlbx t cnnect t the PrtNde. Click n Diagnstics and Debugging Buttn, then click n view, and then n cnnectins. If there are any errrs shwing n the Cnnectin page, please refer t Appendix A.3 fr the relevant wiring and settings. Figure 34: Errr messages screen Appendix A.3. Check Wiring and Settings N COMS n Mdbus RTU side. If Tx/Rx are nt flashing rapidly then there is a COM issue n the Mdbus side. T fix this prblem, check the fllwing: Visual bservatins f LEDs n PrtNde (Appendix A.6) 37

38 Check baud rate, parity, data bits, stp bits Check Mdbus device address Verify wiring Verify all the Mdbus RTU devices that were discvered in Web Cnfiguratr (Sectin 5) Field COM prblems: Visual bservatins f LEDs n PrtNde (Appendix A.6) Visual dipswitch settings (using crrect baud rate and device instance) Verify IP Address setting Verify wiring If the prblem still exists, a Diagnstic Capture needs t be taken and sent t Sierra Mnitr Crpratin. (Appendix A.4) Appendix A.4. Take Diagnstic Capture With the FieldServer Utilities Once the Diagnstic Capture is cmplete, it t supprt@sierramnitr.cm. The Diagnstic Capture will allw us t rapidly diagnse the prblem. Ensure that FieldServer Tlbx is Laded n the PC that is currently being used, r dwnlad FieldServer-Tlbx.zip n the Sierra Mnitr Crpratin webpage, under Custmer Care- Resurce Center, Sftware Dwnlads: Extract the executable file and cmplete the installatin. Ethernet Prt Figure 35: Ethernet Prt Lcatin Disable any wireless Ethernet adapters n the PC/Laptp. Disable firewall and virus prtectin sftware if pssible. Cnnect a standard Cat5 Ethernet cable between the PC and PrtNde. Duble click n the FS Tlbx Utility. 38

39 Step 1: Take a Lg Click n the diagnse icn f the desired device. Select full Diagnstic. If desired, the default capture perid can be changed. 39

40 Click n Start Diagnstic. Wait fr Capture perid t finish. Diagnstic Test Cmplete windw will appear. Step 2: Send Lg Once the Diagnstic test is cmplete, a.zip file will be saved n the PC. Chse pen t launch explrer and have it pint directly at the crrect flder. Send the Diagnstic zip file t supprt@sierramnitr.cm. 40

41 Appendix A.5. BACnet: Setting Netwrk_Number fr mre than ne PrtNde n Subnet Fr bth BACnet MS/TP and BACnet/IP, if mre than ne PrtNde is cnnected t the same subnet, they must be assigned unique Netwrk_Number values. On the main Web Cnfiguratin screen, update the Netwrk Number with the netwrk_nr field and click submit. The default value is 50. Figure 36: Web Cnfiguratr Setting Netwrk Number fr BACnet 41

42 Appendix A.6. LED Diagnstics fr Cmmunicatins Between PrtNde and Devices Please see the diagram belw fr PrtNde FPC-N34 and FPC-N35 LED Lcatins. Diagnstic LEDs Tag SPL RUN ERR RX TX PWR Descriptin The SPL LED will light if the PrtNde is nt getting a respnse frm ne r mre f the cnfigured devices. Fr FPC-N35, the LED will als light until PrtNde is Cmmissined n the LnWrks netwrk. The RUN LED will start flashing 20 secnds after pwer indicating nrmal peratin. The SYS ERR LED will g n slid 15 secnds after pwer up. It will turn ff after 5 secnds. A steady red light will indicate there is a system errr n PrtNde. If this ccurs, immediately reprt the related system errr shwn in the errr screen f the GUI interface t FieldServer Technlgies fr evaluatin. The RX LED will flash when a message is received n the hst prt. The TX LED will flash when a message is sent n the hst prt. This is the pwer light and shuld shw steady green at all times when PrtNde is pwered. Figure 37: Diagnstic LEDs Appendix A.7. Passwrds Access t the PrtNde can be restricted by enabling a passwrd. There are 2 access levels defined by 2 accunt names: Admin and User. The Admin accunt has unrestricted access t the PrtNde. The User accunt can view any PrtNde infrmatin, but cannt make any changes r restart the PrtNde. The passwrd needs t be a minimum f eight characters and is case sensitive. If the passwrd is lst, click cancel n the passwrd authenticatin ppup windw, and the Passwrd recvery tken t supprt@sierramnitr.cm t receive a temprary passwrd frm the Sierra Mnitr supprt team. Access the PrtNde t set a new passwrd. 42

43 Appendix B. Vendr Infrmatin NY Thermal Appendix B.1. Sla Mdbus RTU Mappings t BACnet, Metasys N2 and LnWrks Pint Name BACnet Object Type BACnet Object ID N2 Data Type N2 Pint Address LnWrks Name LnWrks SNVT Outlet Temp (S3S4 Sensr) AI 1 AI 1 nvoutlettmp_xxx SNVT_temp_p Fan Speed AI 2 AI 2 nvfansp_xxx SNVT_cunt_inc_f Flame Signal AI 3 AI 3 nvflmsig_xxx SNVT_cunt_inc_f Inlet Temp (S1 Sensr) AI 4 AI 4 nvinlettmp_xxx SNVT_temp_p DHW Temp (S6 Sensr) AI 5 AI 5 nvdhwtmp_xxx SNVT_temp_p Outdr Temp (S5 Sensr) AI 6 AI 6 nvoutdrtmp_xxx SNVT_temp_p Stack Temp (S8S9 Sensr) AI 7 AI 7 nvstacktmp_xxx SNVT_temp_p 4-20mA Input AI 8 AI 8 nv4_20input_xxx SNVT_cunt_inc_f Firing Rate AV 1 AO 1 nvfirrate_xxx SNVT_cunt_inc_f Active CH Setpint AV 2 AO 2 nvactchsp_xxx SNVT_temp_p Active DHW Setpint AV 3 AO 3 nvactdhwsp_xxx SNVT_temp_p Active LL Setpint AV 4 AO 4 nvactllsp_xxx SNVT_temp_p Active CH Op Pint AV 5 AO 5 nvactchoppt_xxx SNVT_temp_p Active DHW Op Pint AV 6 AO 6 nvacdhwoppt_xxx SNVT_temp_p Active LL Op Pint AV 7 AO 7 nvactlloppt_xxx SNVT_temp_p Active Sys Op Pint AV 8 AO 8 nvacsysoppt_xxx SNVT_temp_p Active Sys Setpint AV 9 AO 9 nvactsyssp_xxx SNVT_temp_p Active Sys On Hysteresis AV 10 AO 10 nvacsyonhys_xxx SNVT_temp_p Active Sys Off Hysteresis AV 11 AO 11 nvacsyofhys_xxx SNVT_temp_p Burner Cycle Cunt AV 12 AO 12 nvbrncycct_xxx SNVT_cunt_inc_f Burner Run Time AV 13 AO 13 nvbrnruntim_xxx SNVT_time_hur CH Pump Cycle Cunt AV 14 AO 14 nvchpmpcyct_xxx SNVT_cunt_inc_f DHW Pump Cycle Cunt AV 15 AO 15 nvdhwpmcyct_xxx SNVT_cunt_inc_f Biler Pump Cycle Cunt AV 16 AO 16 nvblrpmcyct_xxx SNVT_cunt_inc_f CH Max Md Rate AV 17 AO 17 nvchmxmdrat_xxx SNVT_cunt_inc_f 43

44 Pint Name BACnet Object Type BACnet Object ID N2 Data Type N2 Pint Address LnWrks Name LnWrks SNVT DHW Max Md Rate AV 18 AO 18 nvdhwmxmdrt_xxx SNVT_cunt_inc_f Min Md Rate AV 19 AO 19 nvmnmdrate_xxx SNVT_cunt_inc_f Lightff Rate AV 20 AO 20 nvlitoffrat_xxx SNVT_cunt_inc_f Manual Firing Rate AV 21 AO 21 nvmanfirrat_xxx SNVT_cunt_inc_f CH Setpint AV 22 AO 22 nvi/nvchsp_xxx SNVT_temp_p CH TOD Setpint AV 23 AO 23 nvchtodsp_xxx SNVT_temp_p CH On Hysteresis AV 24 AO 24 nvchonhys_xxx SNVT_temp_p CH Off Hysteresis AV 25 AO 25 nvchoffhys_xxx SNVT_temp_p Pstpurge Time AV 26 AO 26 nvpstprgtim_xxx SNVT_time_sec DHW Pririty Override Time AV 27 AO 27 nvdhwprovtm_xxx SNVT_time_sec DHW Setpint AV 28 AO 28 nvi/nvdhwsp_xxx SNVT_temp_p DHW TOD Setpint AV 29 AO 29 nvdhwtodsp_xxx SNVT_temp_p DHW On Hysteresis AV 30 AO 30 nvdhwonhys_xxx SNVT_temp_p DHW Off Hysteresis AV 31 AO 31 nvdhwoffhys_xxx SNVT_temp_p Outlet High Limit Setpint AV 32 AO 32 nvouthilmsp_xxx SNVT_temp_p Stack Limit Setpint AV 33 AO 33 nvstcklimsp_xxx SNVT_temp_p Delta-T Delay AV 34 AO 34 nvdeltdel_xxx SNVT_time_sec T-Rise Delay AV 35 AO 35 nvtrisedel_xxx SNVT_time_sec CH ODR Max Outdr Temp AV 36 AO 36 nvchodrmxot_xxx SNVT_temp_p CH ODR Min Outdr Temp AV 37 AO 37 nvchodrmnot_xxx SNVT_temp_p CH ODR Lw Water Temp AV 38 AO 38 nvchodrlwt_xxx SNVT_temp_p LL CH ODR Max Outdr Temp AV 39 AO 39 nvllchomxot_xxx SNVT_temp_p LL CH ODR Min Outdr Temp AV 40 AO 40 nvllchomnot_xxx SNVT_temp_p LL CH ODR Lw Water Temp AV 41 AO 41 nvllcholwt_xxx SNVT_temp_p LL CH Setpint AV 42 AO 42 nvi/nvllchsp_xxx SNVT_temp_p LL TOD CH Setpint AV 43 AO 43 nvlltodchsp_xxx SNVT_temp_p LL On Hysteresis AV 44 AO 44 nvllonhys_xxx SNVT_temp_p LL Off AV 45 AO 45 nvlloffhys_xxx SNVT_temp_p 44

45 Pint Name BACnet Object Type BACnet Object ID N2 Data Type N2 Pint Address LnWrks Name LnWrks SNVT Hysteresis LL P Gain AV 46 AO 46 nvllpgain_xxx SNVT_cunt_inc_f LL I Gain AV 47 AO 47 nvlligain_xxx SNVT_cunt_inc_f Base Lad Cmmn AV 48 AO 48 nvbseldcm_xxx SNVT_lev_percent Warm Weather Shutdwn Setpint AV 49 AO 49 nvwmwtshtsp_xxx SNVT_temp_p LL Add Stage Errr Threshld AV 50 AO 50 nvllstgerth_xxx SNVT_temp_p LL Add Stage interstage Delay AV 51 AO 51 nvllstgindl_xxx SNVT_time_sec Lead Rtatin Time AV 52 AO 52 nvldrttime_xxx SNVT_time_min Frce Lead Rtatin Time AV 53 AO 53 nvfrcldrttm_xxx SNVT_time_min Slave 1 Address AV 54 AO 54 nvslv1addr_xxx SNVT_cunt_inc_f Slave 1 Stage Order AV 55 AO 55 nvsl1stgord_xxx SNVT_cunt_inc_f Slave 1 Firing Rate AV 56 AO 56 nvsl1firrat_xxx SNVT_lev_percent Slave 2 Address AV 57 AO 57 nvsl2addr_xxx SNVT_cunt_inc_f Slave 2 Stage Order AV 58 AO 58 nvsl2stgord_xxx SNVT_cunt_inc_f Slave 2 Firing Rate AV 59 AO 59 nvsl2firrat_xxx SNVT_lev_percent Slave 3 Address AV 60 AO 60 nvsl3addr_xxx SNVT_cunt_inc_f Slave 3 Stage Order AV 61 AO 61 nvsl3stgord_xxx SNVT_cunt_inc_f Slave 3 Firing Rate AV 62 AO 62 nvsl3firrat_xxx SNVT_lev_percent Slave 4 Address AV 63 AO 63 nvsl4addr_xxx SNVT_cunt_inc_f Slave 4 Stage Order AV 64 AO 64 nvsl4stgord_xxx SNVT_cunt_inc_f Slave 4 Firing Rate AV 65 AO 65 nvsl4firrat_xxx SNVT_lev_percent Slave 5 Address AV 66 AO 66 nvsl5addr_xxx SNVT_cunt_inc_f Slave 5 Stage Order AV 67 AO 67 nvsl5stgord_xxx SNVT_cunt_inc_f Slave 5 Firing Rate AV 68 AO 68 nvsl5firrat_xxx SNVT_lev_percent Slave 6 AV 69 AO 69 nvsl6addr_xxx SNVT_cunt_inc_f 45

46 Pint Name BACnet Object Type BACnet Object ID N2 Data Type N2 Pint Address LnWrks Name LnWrks SNVT Address Slave 6 Stage Order AV 70 AO 70 nvsl6stgord_xxx SNVT_cunt_inc_f Slave 6 Firing Rate AV 71 AO 71 nvsl6firrat_xxx SNVT_lev_percent Slave 7 Address AV 72 AO 72 nvsl7addr_xxx SNVT_cunt_inc_f Slave 7 Stage Order AV 73 AO 73 nvsl7stgord_xxx SNVT_cunt_inc_f Slave 7 Firing Rate AV 74 AO 74 nvsl7firrat_xxx SNVT_lev_percent Slave 8 Address AV 75 AO 75 nvsl8addr_xxx SNVT_cunt_inc_f Slave 8 Stage Order AV 76 AO 76 nvsl8stgord_xxx SNVT_cunt_inc_f Slave 8 Firing Rate AV 77 AO 77 nvsl8firrat_xxx SNVT_lev_percent Lead Biler Address AV 78 AO 78 nvldblraddr_xxx SNVT_cunt_inc_f CH 4 ma Water Temp AV 79 AO 79 nvch4mawttp_xxx SNVT_temp_p CH 20 ma Water Temp AV 80 AO 80 nvc20mawttp_xxx SNVT_temp_p CH ODR Bst Time AV 81 AO 81 nvchodrbttm_xxx SNVT_time_sec Rate Assigned T 0V/4mA AV 82 AO 82 nvrtas0v4ma_xxx SNVT_lev_percent Lead Lag CH 4Ma Water Temp AV 83 AO 83 nvllc4mwttp_xxx SNVT_temp_p Lead Lag CH 20Ma Water Temp AV 84 AO 84 nvllc20mwtt_xxx SNVT_temp_p Lead Lag DHW Setpint AV 85 AO 85 nvlldhwsp_xxx SNVT_temp_p Ll CH ODR Bst Time AV 86 AO 86 nvllchodrbt_xxx SNVT_time_sec Preferred Outlet High Limit AV 87 AO 87 nvprothilim_xxx SNVT_temp_p Preferred Stack Limit AV 88 AO 88 nvprstklim_xxx SNVT_temp_p Preferred Lightff Rate AV 89 AO 89 nvprltofrte_xxx SNVT_cunt_inc_f Interlck/ILK BI 1 DI 1 nvinterlck_xxx SNVT_switch LCI BI 2 DI 2 nvlci_xxx SNVT_switch STAT BI 3 DI 3 nvstat_xxx SNVT_switch Time Of Day (TOD) BI 4 DI 4 nvtimeofday_xxx SNVT_switch Safety Relay BI 5 DI 5 nvsafetyrel_xxx SNVT_switch 46

47 Pint Name BACnet Object Type BACnet Object ID N2 Data Type N2 Pint Address LnWrks Name LnWrks SNVT Annunciatr 1/IAS BI 6 DI 6 nvannun1_xxx SNVT_switch Annunciatr 2 BI 7 DI 7 nvannun2_xxx SNVT_switch Annunciatr 3 BI 8 DI 8 nvannun3_xxx SNVT_switch Annunciatr 4 BI 9 DI 9 nvannun4_xxx SNVT_switch Annunciatr 5 BI 10 DI 10 nvannun5_xxx SNVT_switch Annunciatr 6 BI 11 DI 11 nvannun6_xxx SNVT_switch Annunciatr 7 BI 12 DI 12 nvannun7_xxx SNVT_switch Annunciatr 8 BI 13 DI 13 nvannun8_xxx SNVT_switch Pump A BV 1 DO 1 nvpmpa_xxx SNVT_switch Pump B BV 2 DO 2 nvpmpb_xxx SNVT_switch Pump C BV 3 DO 3 nvpmpc_xxx SNVT_switch Spark Ignitin BV 4 DO 4 nvsparkign_xxx SNVT_switch Pilt Valve BV 5 DO 5 nvpiltval_xxx SNVT_switch Alarm BV 6 DO 6 nvalarm_xxx SNVT_switch Outlet High Limit BV 7 DO 7 nvouthilim_xxx SNVT_switch Stack Limit BV 8 DO 8 nvstacklim_xxx SNVT_switch Delta-T Limit BV 9 DO 9 nvdeltatlim_xxx SNVT_switch Inversin Limit BV 10 DO 10 nvinverslim_xxx SNVT_switch T-rise Limit BV 11 DO 11 nvt_riselim_xxx SNVT_switch Burner Switch BV 12 DO 12 nvbrnswitch_xxx SNVT_switch CH Outdr Reset Enable BV 13 DO 13 nvchotresen_xxx SNVT_switch CH Pump Cntrl (Pump C) BV 14 DO 14 nvchpmpctrl_xxx SNVT_switch DHW Pump Cntrl (Pump A) BV 15 DO 15 nvdhwpmctrl_xxx SNVT_switch Biler Pump Cntrl (Pump B) BV 16 DO 16 nvblrpmctrl_xxx SNVT_switch CH frst Prtect Enable BV 17 DO 17 nvchfrspren_xxx SNVT_switch DHW frst Prtect Enable BV 18 DO 18 nvdhwfrpren_xxx SNVT_switch LL frst Prtect Enable BV 19 DO 19 nvllfrspren_xxx SNVT_switch LL Master Enable BV 20 DO 20 nvllmastren_xxx SNVT_switch LL CH Outdr Reset Enable BV 21 DO 21 nvllchorsen_xxx SNVT_switch CH Enable BV 22 DO 22 nvi/nvch_enable_xxx SNVT_switch DHW Enable BV 23 DO 23 nvi/nvdhwenable_xxx SNVT_switch Demand Surce MV 1 ADI 1 nvdemandsrc_xxx SNVT_switch Burner Cntrl Status MV 2 ADI 2 nvbrnctstat_xxx SNVT_cunt 47

48 Pint Name BACnet Object Type BACnet Object ID N2 Data Type N2 Pint Address LnWrks Name LnWrks SNVT Burner Cntrl State MV 3 ADI 3 nvbrctstate_xxx SNVT_cunt Lckut Cde MV 4 ADI 4 nvlcktcde_xxx SNVT_cunt Hld Cde MV 5 ADI 5 nvhldcde_xxx SNVT_cunt Firing Rate Cntrl MV 6 ADI 6 nvfrratctrl_xxx SNVT_cunt CH Demand Switch MV 7 ADI 7 nvchdemsw_xxx SNVT_cunt CH Md Sensr MV 8 ADI 8 nvchmdsen_xxx SNVT_cunt DHW Demand Switch MV 9 ADI 9 nvdhwdemsw_xxx SNVT_cunt DHW Md Sensr MV 10 ADI 10 nvdhwmdsen_xxx SNVT_cunt LL CH Setpint Surce MV 11 ADI 11 nvllchspsrc_xxx SNVT_cunt LL Md Sensr MV 12 ADI 12 nvllmdsen_xxx SNVT_cunt Slave Mde MV 13 ADI 13 nvslavemde_xxx SNVT_cunt Lead Selectin Methd MV 14 ADI 14 nvldselmeth_xxx SNVT_cunt Lag Selectin Methd MV 15 ADI 15 nvlgselmeth_xxx SNVT_cunt CH Setpint Surce MV 16 ADI 16 nvchspsrc_xxx SNVT_cunt CH Md Rate Surce MV 17 ADI 17 nvchmdrtsrc_xxx SNVT_cunt Outdr Temp Surce MV 18 ADI 18 nvotdrtpsrc_xxx SNVT_cunt Slave 1 State MV 19 ADI 19 nvsl1state_xxx SNVT_cunt Slave 2 State MV 20 ADI 20 nvsl2state_xxx SNVT_cunt Slave 3 State MV 21 ADI 21 nvsl3state_xxx SNVT_cunt Slave 4 State MV 22 ADI 22 nvsl4state_xxx SNVT_cunt Slave 5 State MV 23 ADI 23 nvsl5state_xxx SNVT_cunt Slave 6 State MV 24 ADI 24 nvsl6state_xxx SNVT_cunt Slave 7 State MV 25 ADI 25 nvsl7state_xxx SNVT_cunt Slave 8 State MV 26 ADI 26 nvsl8state_xxx SNVT_cunt Mst Recent Alert MV 27 ADI 27 nvmstrecalt_xxx SNVT_cunt Warm Weather Shutdwn Enable MV 28 ADI 28 nvi/nvwrwtshten_xxx SNVT_cunt Lead Lag CH Demand Switch MV 29 ADI 29 nvllchdemsw_xxx SNVT_cunt Lead Lag DHW Demand Switch MV 30 ADI 30 nvlldhwdmsw_xxx SNVT_cunt 48

49 Appendix C. A Bank DIP Switch Settings Appendix C.1. A Bank DIP Switch Settings Address A0 A1 A2 A3 A4 A5 A6 A7 1 On Off Off Off Off Off Off Off 2 Off On Off Off Off Off Off Off 3 On On Off Off Off Off Off Off 4 Off Off On Off Off Off Off Off 5 On Off On Off Off Off Off Off 6 Off On On Off Off Off Off Off 7 On On On Off Off Off Off Off 8 Off Off Off On Off Off Off Off 9 On Off Off On Off Off Off Off 10 Off On Off On Off Off Off Off 11 On On Off On Off Off Off Off 12 Off Off On On Off Off Off Off 13 On Off On On Off Off Off Off 14 Off On On On Off Off Off Off 15 On On On On Off Off Off Off 16 Off Off Off Off On Off Off Off 17 On Off Off Off On Off Off Off 18 Off On Off Off On Off Off Off 19 On On Off Off On Off Off Off 20 Off Off On Off On Off Off Off 21 On Off On Off On Off Off Off 22 Off On On Off On Off Off Off 23 On On On Off On Off Off Off 24 Off Off Off On On Off Off Off 25 On Off Off On On Off Off Off 26 Off On Off On On Off Off Off 27 On On Off On On Off Off Off 28 Off Off On On On Off Off Off 29 On Off On On On Off Off Off 30 Off On On On On Off Off Off 31 On On On On On Off Off Off 32 Off Off Off Off Off On Off Off 33 On Off Off Off Off On Off Off 34 Off On Off Off Off On Off Off 35 On On Off Off Off On Off Off 36 Off Off On Off Off On Off Off 37 On Off On Off Off On Off Off 38 Off On On Off Off On Off Off 39 On On On Off Off On Off Off 40 Off Off Off On Off On Off Off 41 On Off Off On Off On Off Off 42 Off On Off On Off On Off Off 43 On On Off On Off On Off Off 44 Off Off On On Off On Off Off 45 On Off On On Off On Off Off 46 Off On On On Off On Off Off Address A0 A1 A2 A3 A4 A5 A6 A7 47 On On On On Off On Off Off 48 Off Off Off Off On On Off Off 49 On Off Off Off On On Off Off 50 Off On Off Off On On Off Off 51 On On Off Off On On Off Off 52 Off Off On Off On On Off Off 53 On Off On Off On On Off Off 54 Off On On Off On On Off Off 55 On On On Off On On Off Off 56 Off Off Off On On On Off Off 57 On Off Off On On On Off Off 58 Off On Off On On On Off Off 59 On On Off On On On Off Off 60 Off Off On On On On Off Off 61 On Off On On On On Off Off 62 Off On On On On On Off Off 63 On On On On On On Off Off 64 Off Off Off Off Off Off On Off 65 On Off Off Off Off Off On Off 66 Off On Off Off Off Off On Off 67 On On Off Off Off Off On Off 68 Off Off On Off Off Off On Off 69 On Off On Off Off Off On Off 70 Off On On Off Off Off On Off 71 On On On Off Off Off On Off 72 Off Off Off On Off Off On Off 73 On Off Off On Off Off On Off 74 Off On Off On Off Off On Off 75 On On Off On Off Off On Off 76 Off Off On On Off Off On Off 77 On Off On On Off Off On Off 78 Off On On On Off Off On Off 79 On On On On Off Off On Off 80 Off Off Off Off On Off On Off 81 On Off Off Off On Off On Off 82 Off On Off Off On Off On Off 83 On On Off Off On Off On Off 84 Off Off On Off On Off On Off 85 On Off On Off On Off On Off 86 Off On On Off On Off On Off 87 On On On Off On Off On Off 88 Off Off Off On On Off On Off 89 On Off Off On On Off On Off 90 Off On Off On On Off On Off 91 On On Off On On Off On Off 92 Off Off On On On Off On Off 49

50 Address A0 A1 A2 A3 A4 A5 A6 A7 93 On Off On On On Off On Off 94 Off On On On On Off On Off 95 On On On On On Off On Off 96 Off Off Off Off Off On On Off 97 On Off Off Off Off On On Off 98 Off On Off Off Off On On Off 99 On On Off Off Off On On Off 100 Off Off On Off Off On On Off 101 On Off On Off Off On On Off 102 Off On On Off Off On On Off 103 On On On Off Off On On Off 104 Off Off Off On Off On On Off 105 On Off Off On Off On On Off 106 Off On Off On Off On On Off 107 On On Off On Off On On Off 108 Off Off On On Off On On Off 109 On Off On On Off On On Off 110 Off On On On Off On On Off 111 On On On On Off On On Off 112 Off Off Off Off On On On Off 113 On Off Off Off On On On Off 114 Off On Off Off On On On Off 115 On On Off Off On On On Off 116 Off Off On Off On On On Off 117 On Off On Off On On On Off 118 Off On On Off On On On Off 119 On On On Off On On On Off 120 Off Off Off On On On On Off 121 On Off Off On On On On Off 122 Off On Off On On On On Off 123 On On Off On On On On Off 124 Off Off On On On On On Off 125 On Off On On On On On Off 126 Off On On On On On On Off 127 On On On On On On On Off 128 Off Off Off Off Off Off Off On 129 On Off Off Off Off Off Off On 130 Off On Off Off Off Off Off On 131 On On Off Off Off Off Off On 132 Off Off On Off Off Off Off On 133 On Off On Off Off Off Off On 134 Off On On Off Off Off Off On 135 On On On Off Off Off Off On 136 Off Off Off On Off Off Off On 137 On Off Off On Off Off Off On 138 Off On Off On Off Off Off On 139 On On Off On Off Off Off On 140 Off Off On On Off Off Off On 141 On Off On On Off Off Off On Address A0 A1 A2 A3 A4 A5 A6 A7 142 Off On On On Off Off Off On 143 On On On On Off Off Off On 144 Off Off Off Off On Off Off On 145 On Off Off Off On Off Off On 146 Off On Off Off On Off Off On 147 On On Off Off On Off Off On 148 Off Off On Off On Off Off On 149 On Off On Off On Off Off On 150 Off On On Off On Off Off On 151 On On On Off On Off Off On 152 Off Off Off On On Off Off On 153 On Off Off On On Off Off On 154 Off On Off On On Off Off On 155 On On Off On On Off Off On 156 Off Off On On On Off Off On 157 On Off On On On Off Off On 158 Off On On On On Off Off On 159 On On On On On Off Off On 160 Off Off Off Off Off On Off On 161 On Off Off Off Off On Off On 162 Off On Off Off Off On Off On 163 On On Off Off Off On Off On 164 Off Off On Off Off On Off On 165 On Off On Off Off On Off On 166 Off On On Off Off On Off On 167 On On On Off Off On Off On 168 Off Off Off On Off On Off On 169 On Off Off On Off On Off On 170 Off On Off On Off On Off On 171 On On Off On Off On Off On 172 Off Off On On Off On Off On 173 On Off On On Off On Off On 174 Off On On On Off On Off On 175 On On On On Off On Off On 176 Off Off Off Off On On Off On 177 On Off Off Off On On Off On 178 Off On Off Off On On Off On 179 On On Off Off On On Off On 180 Off Off On Off On On Off On 181 On Off On Off On On Off On 182 Off On On Off On On Off On 183 On On On Off On On Off On 184 Off Off Off On On On Off On 185 On Off Off On On On Off On 186 Off On Off On On On Off On 187 On On Off On On On Off On 188 Off Off On On On On Off On 189 On Off On On On On Off On 190 Off On On On On On Off On 50

51 Address A0 A1 A2 A3 A4 A5 A6 A7 191 On On On On On On Off On 192 Off Off Off Off Off Off On On 193 On Off Off Off Off Off On On 194 Off On Off Off Off Off On On 195 On On Off Off Off Off On On 196 Off Off On Off Off Off On On 197 On Off On Off Off Off On On 198 Off On On Off Off Off On On 199 On On On Off Off Off On On 200 Off Off Off On Off Off On On 201 On Off Off On Off Off On On 202 Off On Off On Off Off On On 203 On On Off On Off Off On On 204 Off Off On On Off Off On On 205 On Off On On Off Off On On 206 Off On On On Off Off On On 207 On On On On Off Off On On 208 Off Off Off Off On Off On On 209 On Off Off Off On Off On On 210 Off On Off Off On Off On On 211 On On Off Off On Off On On 212 Off Off On Off On Off On On 213 On Off On Off On Off On On 214 Off On On Off On Off On On 215 On On On Off On Off On On 216 Off Off Off On On Off On On 217 On Off Off On On Off On On 218 Off On Off On On Off On On 219 On On Off On On Off On On 220 Off Off On On On Off On On 221 On Off On On On Off On On 222 Off On On On On Off On On 223 On On On On On Off On On 224 Off Off Off Off Off On On On 225 On Off Off Off Off On On On 226 Off On Off Off Off On On On 227 On On Off Off Off On On On 228 Off Off On Off Off On On On 229 On Off On Off Off On On On 230 Off On On Off Off On On On 231 On On On Off Off On On On 232 Off Off Off On Off On On On 233 On Off Off On Off On On On 234 Off On Off On Off On On On 235 On On Off On Off On On On 236 Off Off On On Off On On On 237 On Off On On Off On On On 238 Off On On On Off On On On 239 On On On On Off On On On Address A0 A1 A2 A3 A4 A5 A6 A7 240 Off Off Off Off On On On On 241 On Off Off Off On On On On 242 Off On Off Off On On On On 243 On On Off Off On On On On 244 Off Off On Off On On On On 245 On Off On Off On On On On 246 Off On On Off On On On On 247 On On On Off On On On On 248 Off Off Off On On On On On 249 On Off Off On On On On On 250 Off On Off On On On On On 251 On On Off On On On On On 252 Off Off On On On On On On 253 On Off On On On On On On 254 Off On On On On On On On 255 On On On On On On On On 51

52 Appendix D. Reference Appendix D.1. Specificatins Electrical Cnnectins Apprvals Pwer Requirements Physical Dimensins Weight PrtNde FPC-N34 One 6-pin Phenix cnnectr with: RS-485 prt (+ / - / gnd) Pwer prt (+ / - / Frame-gnd) One 3-pin Phenix cnnectr with: RS-485 prt (+ / - / gnd) One Ethernet 10/100 BaseT prt PrtNde FPC-N35 One 6-pin Phenix cnnectr with: RS-485 prt (+ / - / gnd) Pwer prt (+ / - / Frame-gnd) One Ethernet 10/100 BaseT prt One FTT-10 LnWrks prt CE Certified; TUV apprved t UL 916, EN , EN and CSA C22-2 standards; FCC Class A Part 15; DNP3 Cnfrmance Tested; RHS Cmpliant; CSA 205 Apprved BTL Marked LnMark Certified Multi-mde pwer adapter: 9-30VDC r 12-24VAC 11.5 cm L x 8.3 cm W x 4.1 cm H (4.5 x 3.2 x 1.6 in.) 0.2 kg (0.4 lbs) Operating Temperature -40 C t 75 C (-40 F t167 F) Surge Suppressin Humidity EN ESD EN EMC EN EFT 5-90% RH (nn-cndensing) (Specificatins subject t change withut ntice) Figure 38: Specificatins Appendix D.1.1. Cmpliance with UL Regulatins Fr UL cmpliance, the fllwing instructins must be met when perating PrtNde. The units shall be pwered by listed LPS r Class 2 pwer supply suited t the expected perating temperature range. The intercnnecting pwer cnnectr and pwer cable shall: Cmply with lcal electrical cde Be suited t the expected perating temperature range Meet the current and vltage rating fr PrtNde/Net Furthermre, the intercnnecting pwer cable shall: Be f length nt exceeding 3.05m (118.3 ) Be cnstructed f materials rated VW-1, FT-1 r better If the unit is t be installed in an perating envirnment with a temperature abve 65 C, it shuld be installed in a Restricted Access Area requiring a key r a special tl t gain access. This device must nt be cnnected t a LAN segment with utdr wiring. 52

APPLICABILITY & EFFECTIVITY

APPLICABILITY & EFFECTIVITY PrtNde FPC-N34 and PrtNde FPC-N35 Startup Guide Fr Interfacing Eatn-Cper Prducts: Greengate and ilumin T Building Autmatin Systems: BACnet MS/TP, BACnet/IP, Mdbus TCP/IP, Mdbus RTU and LnWrks APPLICABILITY

More information

WM part number (ProtoNode FPC-N34 for BACnet ) and WM part number (ProtoNode FPC-N35 for LonMark ) Startup Guide

WM part number (ProtoNode FPC-N34 for BACnet ) and WM part number (ProtoNode FPC-N35 for LonMark ) Startup Guide WM part number 383-600-322 (PrtNde FPC-N34 fr BACnet ) and WM part number 383-600-332 (PrtNde FPC-N35 fr LnMark ) Startup Guide Fr Interfacing Weil-McLain Prducts: SlimFit 1000-2000, SlimFit 550/750, and

More information

APPLICABILITY & EFFECTIVITY

APPLICABILITY & EFFECTIVITY PrtNde FPC-N34 and PrtNde FPC-N35 Startup Guide Fr Interfacing Harsc Industrial Pattersn-Kelley Prducts: ENVI Cntrl Systems and Lve Cntrller T Building Autmatin Systems: BACnet MS/TP, BACnet/IP, Mdbus

More information

APPLICABILITY & EFFECTIVITY

APPLICABILITY & EFFECTIVITY PrtNde FPC-N34 and PrtNde FPC-N35 Startup Guide Fr Interfacing Triangle Tube Prducts: Prestige and Keystne T Building Autmatin Systems: BACnet MS/TP, BACnet/IP, Mdbus/TCP, Metasys N2 and LnWrks APPLICABILITY

More information

ProtoNode Start-up Guide

ProtoNode Start-up Guide PrtNde Start-up Guide FPC-N34, FPC-N35, FPC-N36, FPC-N37, FPC-N38, FPC-N39, FPC-N40, FPC-N41 and FPC-N42 APPLICABILITY & EFFECTIVITY Effective fr all systems manufactured after June 2016. Dcument Revisin:

More information

APPLICABILITY & EFFECTIVITY

APPLICABILITY & EFFECTIVITY PrtNde FPC-N34 and PrtNde FPC-N35 Startup Guide Fr Interfacing Harsc Industrial Pattersn-Kelley Prducts: ENVI Cntrl Systems, Lve Cntrller and Nur T Building Autmatin Systems: BACnet MS/TP, BACnet/IP, Mdbus

More information

Document Revision: 12.C Auto Selector Template Revision: 49

Document Revision: 12.C Auto Selector Template Revision: 49 PrtNde FPC-N34 and PrtNde FPC-N35 Startup Guide Fr Interfacing Lchinvar Prducts: SYNC, Knight /Knight XL /Armr/Wall Munt/Wall Hung, Crest, Cpper-Fin II, Pwer Fin, Knight FTXL T Building Autmatin Systems:

More information

ProtoNode FPC-N34 and FPC-N35

ProtoNode FPC-N34 and FPC-N35 ProtoNode FPC-N34 and FPC-N35 FOR BUDERUS SSB BOILERS Installation and Service Instructions for Contractors 6720818452 (2015/10) US 3.4 2 Contents 1 Key to symbols and safety instructions... 3 1.1 Key

More information

ProtoNode RER and ProtoNode LER. Startup Guide

ProtoNode RER and ProtoNode LER. Startup Guide ProtoNode RER and ProtoNode LER Startup Guide For Interfacing Customer Product: Harsco Industrial Patterson-Kelley ENVI Control Systems and Love Controller To Building Automation Systems: BACnet MS/TP,

More information

ET9500 BEMS Interface Box Configuration Guide

ET9500 BEMS Interface Box Configuration Guide ET9500 BEMS Interface Box Configuration Guide APPLICABILITY & EFFECTIVITY Explains how to install and configure ET9500 BEMS Interface Box. The instructions are effective for the above as of August, 2015

More information

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35 Version 4.2 - Rev. 2017-11-30 5580 Enterprise Pkwy. Fort Myers, FL 33905 MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35 Office: 239-694-0089 Fax: 239-694-0031 www.mcscontrols.com MCS Total Solution

More information

EIP APPLICABILITY & EFFECTIVITY

EIP APPLICABILITY & EFFECTIVITY ProtoCessor ProtoNode RER Startup Guide For Interfacing Toshiba Products: G8000 & G9000 To Building Automation Systems: Modbus/RTU, Modbus/TCP, BACnet MS/TP, BACnet/IP, Metasys N2, SNMP and AB EIP APPLICABILITY

More information

Thermal Solutions Communications Gateway Instruction Manual Part Number Revised: April 13, 2015 Contents

Thermal Solutions Communications Gateway Instruction Manual Part Number Revised: April 13, 2015 Contents Thermal Solutions Communications Gateway Instruction Manual Part Number 104568-01 Revised: April 13, 2015 Contents 1. Introduction 2 2. ProtoNode Setup 3 3. Wiring 7 4. Commissioning 16 5. Field Validating

More information

ProtoNode RER and ProtoNode LER Startup Guide For Interfacing Infinite Energy 2 Products: Argus Managing/Standalone Boiler and Dependent Boiler To

ProtoNode RER and ProtoNode LER Startup Guide For Interfacing Infinite Energy 2 Products: Argus Managing/Standalone Boiler and Dependent Boiler To ProtoNode RER and ProtoNode LER Startup Guide For Interfacing Infinite Energy 2 Products: Argus Managing/Standalone Boiler and Dependent Boiler To Building Automation Systems: BACnet MS/TP, BACnet/IP,

More information

Trouble Shooting Guide for AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves)

Trouble Shooting Guide for AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves) Truble Shting Guide fr AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves) AFVK-SP, AFVK-SP-H/L, AFVK-SP-MH/L AFVK-SP Series Valve Kit Truble Shting Guide (AF-4000 Series) TABLE OF CONTENTS General Infrmatin

More information

Document Revision: 4.4

Document Revision: 4.4 ProtoNode RER and ProtoNode LER Startup Guide For Interfacing Camus Products: Honeywell Sola (DynaFlame, Dynaforce, DynaMax HS, TH Series, Advantus TM ) To Building Automation Systems: BACnet MS/TP, BACnet/IP,

More information

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm)

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm) Hw t Install the Batteries Hw t Hld the Lamp: The InteliEnergy Lamp selectin switches utilize the same technlgy as cell phnes: Capacitive Tuch. This assures the ultimate in lngevity because there are n

More information

EnergyBar 6. Setup Guide

EnergyBar 6. Setup Guide EnergyBar 6 Setup Guide WELCOME Cngratulatins n yur purchase f the Apex EnergyBar 6! The EnergyBar 6 allws the Apex system t cntrl up t six 230 vlt items such as lights, pumps, fans, heaters, chillers

More information

Aviatrix GCloud Cloud Connect Startup Guide

Aviatrix GCloud Cloud Connect Startup Guide Clud Cntrller Startup Guide Aviatrix GClud Clud Cnnect Startup Guide Versin 10-16-2016 Cpyright 2014-2016 Aviatrix Systems, Inc. All rights reserved. Aviatrix Systems Page 0 GClud Cntrller Startup Guide

More information

Installation Guide Contigo 6100

Installation Guide Contigo 6100 Installatin Guide Cmmercial Vehicle Prductivity and Security The is a high-perfrmance beacn designed fr cmmercial prductivity and security. It is ideally suited t installatins in delivery and service fleets

More information

Release Notes - Zebra ET55 Android L LifeGuard Update 08 Release for WWAN GMS

Release Notes - Zebra ET55 Android L LifeGuard Update 08 Release for WWAN GMS Release Ntes - Zebra ET55 Andrid L LifeGuard Update 08 Release fr WWAN GMS Cntents Descriptin Device Cmpatibility Cmpnent Cntents Installatin Requirements Installatin Instructins Dwnladable Sftware included

More information

Open Street Cam User Manual

Open Street Cam User Manual Open Street Cam User Manual Table f cntent 1.Installing the app and setting it up fr the first time 1.1 Installing the app 1.2 Setting up the app fr the first time 2. Installing the smartphne in the car

More information

JD F Conversion. Combine Manual a

JD F Conversion. Combine Manual a JD 9000-600F Cnversin Cmbine Manual 09040114a Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm Technical

More information

DriveCam Unit Installation Instructions

DriveCam Unit Installation Instructions DriveCam Unit Installatin Instructins Installatin f the DriveCam Unit is nt cmplicated, thugh care must be taken t avid specific prblems. Sme vehicles require additinal cnsideratin t determine the ptimum

More information

QuickServer Industrial Protocol Gateway

QuickServer Industrial Protocol Gateway Manual No: 577014-367 Revision: A QuickServer Industrial Protocol Gateway Startup Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to,

More information

Instruction Manual. PHscan30 Pocket ph Tester

Instruction Manual. PHscan30 Pocket ph Tester Hazardus Substance Statement Bante is cmmitted t the reductin and eventual eliminatin f all hazardus substances in bth the manufacturing prcess and finished prducts we supply. We have an active manufacturing

More information

Appointment Plus User Instructions

Appointment Plus User Instructions Appintment Plus User Instructins This dcument prvides the user with instructins fr the Appintment Plus System. Appintment Plus System Features This is a tl fr managing the fllwing: Technician Wrk Frce

More information

AMERICAN IRON HORSE IGNITER TEST BOX

AMERICAN IRON HORSE IGNITER TEST BOX Gill Instruments AMERICAN IRON HORSE IGNITER TEST BOX L.E.D. ARRAY IGNITER TYPE SELECTOR SWITCH 12V BATIERY SUPPLY CONNECTORS IGNITER CONNECTOR COMPONENT IDENTIFICATION The Test Bx cnsists f the fllwing:

More information

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS 120 Mdel: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This Wired Wall Timer system was

More information

Medication Cart. Featuring AutoLock Security System. Product Manual

Medication Cart. Featuring AutoLock Security System. Product Manual AC Medicatin Cart Featuring AutLck Security System Prduct Manual Cpyright and Distributin Ntice December 2009 Cpyright 2009 Capsa Slutins, Inc. ALL RIGHTS RESERVED. Published 2014. Printed in the United

More information

Installation instructions: 13 Pin Electrical system for towing hitch

Installation instructions: 13 Pin Electrical system for towing hitch General data Part number Westfalia Vehicle Manufacturer Vehicle 321 538 300 153 ZGB 1T0 055 204 Vlkswagen Turan MY 2003> 321 538 391 105-005 - 33/07 Imprtant ntes Read the installatin manual prir t starting

More information

E+ Battery Care Guide

E+ Battery Care Guide Electric Mtin Systems, LLC 45150 Business Curt, Suite 300 Dulles, VA 20166 USA E+ Battery Care Guide Welcme! Yur E+ Hub Battery Pack is a pwerful, sphisticated, and imprtant part f yur E+ Electric Bicycle.

More information

Thermal Solutions Universal Gateway Part Number: Instruction Manual June 11, 2015 Revision 10

Thermal Solutions Universal Gateway Part Number: Instruction Manual June 11, 2015 Revision 10 Thermal Solutions Universal Gateway Part Number: 106417-01 Instruction Manual June 11, 2015 evision 10 Contents 1. Introduction 4 2. Setup 5 3. Wiring 11 4. Commissioning 23 5. Field Validating 29 6. Troubleshooting

More information

Uninterruptible Current Supply USV V / 1.2 Ah

Uninterruptible Current Supply USV V / 1.2 Ah Uninterruptible Current Supply USV 011 +24 V / 1.2 Ah The USV 011 Uninterruptible current supply is used t buffer the +24 V supply f an Industry PC (C-IPC, SIPC). The +24 V supply is nrmally cnnected t

More information

VEHICLE ACTIVATED SPEED LIMIT SIGNS

VEHICLE ACTIVATED SPEED LIMIT SIGNS VEHICLE ACTIVATED SPEED LIMIT SIGNS TRS-VASL VEHICLE ACTIVATED SPEED LIMIT SIGNS Vehicle Activated Speed Limit (VASL) signs measure the speed f appraching vehicles. If the speed f the vehicle is higher

More information

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems!

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems! The HB Series Advantage SGS listed cnfirming t UL Standard 2108 & 8750 Certified t CSA Standard C22.2 N.9 LED Life f 50K+ hurs, under nrmal perating cnditins Lw wattage, lw heat, lw vltage (12DVC & 24VDC

More information

ADVISORY: General Motors Upfitter Integration Bulletin #108d P a g e 1 May 18, 2016

ADVISORY: General Motors Upfitter Integration  Bulletin #108d P a g e 1 May 18, 2016 Subject: Aftermarket ALDL r DLC Interface Devices Causing Multiple Issues Mdels All Passenger Cars and Trucks Affected: Mdel Years: 2006 and beynd Date: February 4, 2013 Revisin Date: May 18, 2016 ADVISORY:

More information

Installation Guide Contigo 6150 & 6151

Installation Guide Contigo 6150 & 6151 Installatin Guide Cntig 6150 & 6151 Cmmercial Vehicle Prductivity and Security The Cntig 6150 & 6151* (cllectively knwn as the Cntig 615X) are highperfrmance beacns designed fr cmmercial prductivity and

More information

Tools Required. Installation. Step 1. Headlight lense removal (Driver's side shown, Passenger side similar)

Tools Required. Installation. Step 1. Headlight lense removal (Driver's side shown, Passenger side similar) Tls Required Phillips Screw Driver (crner lamps) Flat Head Screw Driver (ptinal fr headlight cver) Pliers (handy t have) Electrical Tape Sturdy Cpper Wire (t use as a wire fish) 10mm Scket r Wrench (grund

More information

Event Scheduling Guide Gen II

Event Scheduling Guide Gen II Event Scheduling Guide Gen II Scheduling events is menu-driven and very easy t d. Step-by-step instructins in this Guide will help yu the first time yu schedule an event. Open the cin dr. Press the red

More information

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator TECHNICAL SPECIFICATION SPC-4T Stirling Prcess Crygeneratr Reference 80 8044_00 Issue Date April 20, 2016 Stirling Crygenics is a registered trade name f DH Industries BV Fr mre infrmatin n the Stirling

More information

Universal Communication Gateway Instruction Manual

Universal Communication Gateway Instruction Manual Universal Communication Gateway Instruction Manual The Universal Communication Gateway (UCG) is an external, high performance, low cost building automation multi-protocol gateway that has been preprogrammed

More information

Advanced 3 Million Wireless USB Limousine Underbody Kit

Advanced 3 Million Wireless USB Limousine Underbody Kit Advanced 3 Millin Wireless USB Limusine Underbdy Kit Warning: Please check yur state and lcal laws befre installing this LED underbdy kit. Every state has different plicies and prcedures in place regarding

More information

EDBRO RIGID INCLINOMETER

EDBRO RIGID INCLINOMETER EDBRO RIGID INCLINOMETER RINC01 Installatin & Operating Instructins E5542 rev 1 (June 2010) Edbr PLC Nelsn Street, Bltn BL3 2JJ UK Tel: +44 (0) 120 4528888 Fax: +44 (0) 120 4531957 E-mail: pstmaster@edbr.cm

More information

Tips & Technology For Bosch business partners

Tips & Technology For Bosch business partners Tips & Technlgy Fr Bsch business partners Current tpics fr successful wrkshps N. 35/2011 Gasline injectin Invented fr life Lambda sensr Knw-hw frm the market leader Bsch, innvative cmpany and wrld's largest

More information

Genesys Certification Study Guide

Genesys Certification Study Guide Genesys Certificatin Study Guide Genesys Certified Prfessinal 8 System Cnsultant, iwd Slutin (GCP8 - CiWD) Exam Cde Type f Exam Number f Items GCP8-CiWD (Prmetric cde: GE0_809) Written, multiple-chice

More information

BPC955 V0 Bliss Powercom Genset Controller. Kirloskar Electric Co. Ltd. User Manual

BPC955 V0 Bliss Powercom Genset Controller. Kirloskar Electric Co. Ltd. User Manual BPC955 V0 Bliss Pwercm Genset Cntrller Kirlskar Electric C. Ltd User Manual This dcument applies t Prduct 9001-0049 Build Versin 3600-0129 Firmware Versin 5000-xxxx The infrmatin cntained in this dcument

More information

ALL components will be installed on the top of the board with the exception of the OPTIONAL dual battery holder.

ALL components will be installed on the top of the board with the exception of the OPTIONAL dual battery holder. ASSEMBLING THE BOARD The cmpnent list can be fund n the last 2 pages f this dcument. Refer t it when installing cmpnents n the bard. All cmpnents lcatins are numbered and the cmpnent list shws the crrespnding

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Observer Zning Bard ZONE0101ZP6 These instructins must be read and understd cmpletely befre attempting installatin Safety Labeling and Signal Wrds DANGER, WARNING, CAUTION, and

More information

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D),

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), SERVICE REPLACES: Please discard ATV 07-02 dated 4/5/07 MODEL: PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), KFX700 (KSV700-A/B/C),

More information

Headsight HHC HH 14 series. Combine Manual

Headsight HHC HH 14 series. Combine Manual Headsight HHC HH 14 series Cmbine Manual 09010204 Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm Technical

More information

Car Refrigerator PFN-C-WEA-25/35/45/55

Car Refrigerator PFN-C-WEA-25/35/45/55 Car Refrigeratr PFN-C-WEA-25/35/45/55 Accessries available separately:- Prtective Transit Bag AC0V -240Vt DC 2 V Pwer Adaptr Please read this manual carefully befre using yur unit. Sectin Page Key Prduct

More information

SOMSAS Student User Manual Overseas Short Term Programs

SOMSAS Student User Manual Overseas Short Term Programs SOMSAS Student User Manual Overseas Shrt Term Prgrams Table f cntents WHAT IS SOMSAS? 2 CREATE A NEW APPLICATION 2 Shrt Term Prgram 3 ADD SUBJECTS TO YOUR APPLICATION 3 Hst Institutin Details 4 Partner

More information

/2017. Flexline rapid clamping systems with drive chain clamping element, T-slot and adjustment track

/2017. Flexline rapid clamping systems with drive chain clamping element, T-slot and adjustment track Traveling unit chain (adjustment track) in 3 lengths s in varius designs Mtr Advantages 8 different clamping elements 4 different T-slts 3 different adjustment tracks drive mtr and die mnitr attachable

More information

WELCOME. WEB LOCATION Los Angeles, CA

WELCOME. WEB   LOCATION Los Angeles, CA WELCOME Thank yu fr chsing AC Infinity. We are cmmitted t prduct quality and friendly custmer service. If yu have any questins r suggestins, please dn t hesitate t cntact us. Visit www.acinfinity.cm and

More information

Audi 8L A3 and B5 A4 ColorMFA Install Guide ColorMFA from AutoPilot. Instructions from Clusters by Litke and pinout from Drive2

Audi 8L A3 and B5 A4 ColorMFA Install Guide ColorMFA from AutoPilot. Instructions from Clusters by Litke and pinout from Drive2 Audi 8L A3 and B5 A4 ClrMFA Install Guide ClrMFA frm AutPilt. Instructins frm Clusters by Litke and pinut frm Drive2 This is an verview guide n hw t install the v3.2/v3.4 ClrMFA units int Audi 8L and B5

More information

Hub/Remote Operations in version 3.0

Hub/Remote Operations in version 3.0 Hub/Remte Operatins in versin 3.0 In StckTrac Enterprise 3.0, the Hub and Remte perate quite a bit differently than they did in 2.0. In 2.0, the shps stred their business fr the day int daily files which

More information

Frequently Asked Fleet Card Questions HuskyPRO Universal Fuel Card

Frequently Asked Fleet Card Questions HuskyPRO Universal Fuel Card Frequently Asked Fleet Card Questins HuskyPRO Universal Fuel Card General Fleet Card Accunt Questins Hw can the HuskyPRO Universal Fuel Card Prgram help me manage my business fleet fuel expenses? HuskyPRO

More information

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW D yu yu need reliable AC pwer in a vehicle, remte lcatin r fr emergency back-up? Samlex s inverter/charger is THE chice fr a cmplete ff-grid pwer slutin. Off-Grid Pwer Slutins LUTION SERIES S Sine 1 Pure

More information

C-BOA Tool Validation of Energy Savings Estimation Methods

C-BOA Tool Validation of Energy Savings Estimation Methods C-BOA Tl Validatin f Energy Estimatin Methds February 21, 2012 1 f 7 Table f Cntents Summary... 3 Recmmendatin... 3 Evaluatin Apprach... 3 Technical Advisry Grup Oversight... 3 Prject Specificatins...

More information

Truxbox ELD User manual

Truxbox ELD User manual Truxbx ELD User manual Versin 04.17.001 Truxbx ELD TT1.01 2012-2017 TruxTrax.cm, Inc. All rights reserved. Terms, features, availability, pricing, fees, and supprt ptins are subject t change withut ntice.

More information

Quark Brushless Systems

Quark Brushless Systems Quark Brushless Systems Instructin Manual fr Quark 22A/33A Universal Versin 2 Speed cntrller needs t be cmpletely checked after a mdel crash. Never use a damaged ESC. The heat sink n the ESC must be used

More information

Anemómetros digitales portátiles AN-100 extech manual ingles USER MANUAL. Model AN100. CFM/CMM Thermo Anemometer AN100

Anemómetros digitales portátiles AN-100 extech manual ingles   USER MANUAL. Model AN100. CFM/CMM Thermo Anemometer AN100 USER MANUAL CFM/CMM Therm Anemmeter Mdel AN100 CFM/CMM Therm-Anemmeter AN100 Intrductin Cngratulatins n yur purchase f the Extech AN100 CFM/CMM Therm Anemmeter. This instrument measures Air Velcity, Air

More information

NEXT UPS Systems MANTIS II Tower 750/1000/1500 Installation and user manual English

NEXT UPS Systems MANTIS II Tower 750/1000/1500 Installation and user manual English NEXT UPS Systems MANTIS II Twer 750/1000/1500 Installatin and user manual English CONTENT IMPORTANT SAFETY INSTRUCTIONS... 1 1. Intrductin... 4 2. Descriptin f Features... 4 3. Package Cntents... 4 4.

More information

CS369-R51I Thank you very much for purchasing our air conditioner.

CS369-R51I Thank you very much for purchasing our air conditioner. OWNER'S MANUAL CONDITIONER REMOTE CONTROLLER ILLUSTRATION The design and specificatins are subject t change withut prir ntice fr prduct imprvement. Cnsult with the sales agency r manufacturer fr details.

More information

A L L Diagnostic Trouble Codes ( DTC ): P Code Charts P0302

A L L Diagnostic Trouble Codes ( DTC ): P Code Charts P0302 2012 Chrysler Truck Twn & Cuntry V6-3.6L Cpyright 2013, ALLDATA 10.52 Page 1 A L L Diagnstic Truble Cdes ( DTC ): P Cde Charts P0302 P0302-CYLINDER 2 MISFIRE Special Tls: Fr a cmplete wiring diagram, refer

More information

DTC P0401 Exhaust Gas Recirculation Flow Insufficient Detected

DTC P0401 Exhaust Gas Recirculation Flow Insufficient Detected DTC P0401 Exhaust Gas Recirculatin Flw Insufficient Detected DESCRIPTION Based n the driving cnditins, the ECM regulates the vlume f exhaust gas that is recirculated t the engine's cmbustin chambers and

More information

Adobe Connect Web Conferencing

Adobe Connect Web Conferencing Adbe Cnnect Web Cnferencing Befre yu begin Befre reading this dcument, please review the fllwing nline dems and dcuments: Review System Requirements http://www.adbe.cm/prducts/acrbatcnnectpr/systemreqs/

More information

General Faucet Installation Instructions

General Faucet Installation Instructions General Faucet Installatin Instructins Step 1: Psitin the Faucet Begin installing yur faucet by placing the gasket and faucet in psitin n the sink. (Diagram A) Frm under the sink, thread the plastic munting

More information

Drying ovens, incubators, cooled incubators

Drying ovens, incubators, cooled incubators rying vens, incubatrs, cled incubatrs rying vens, incubatrs, cled incubatrs All the units in the ST versin are equipped with a PI micrprcessr cntrller with an LC graphic display and illuminated tuch buttns.

More information

72 Mustang Mach 1 tachometer cluster and gauge conversion

72 Mustang Mach 1 tachometer cluster and gauge conversion 72 Mustang Mach 1 tachmeter cluster and gauge cnversin Dated: 02-17-2009 (drafted by a Chevy persn wrking n his first Frd -nt gd-) The fllwing infrmatin pertains t hw I went abut cnverting the standard

More information

2-CHANNEL WIRELESS REMOTE CONTROL SYSTEM EWC-2

2-CHANNEL WIRELESS REMOTE CONTROL SYSTEM EWC-2 2-CHANNEL WIRELESS REMOTE CONTROL SYSTEM EWC-2 "Fingertip cntrl withut hard-wiring" CONTROL TWO LOW VOLTAGE DEVICES OR OPERATIONS FROMA CONVENIENT POCKET SIZED REMOTE ~:::.~.~ I,- L. ~'~~~I..~ "J THANK

More information

Draft ADEM Guidance Proposed Additions to the Alabama UST Regulations

Draft ADEM Guidance Proposed Additions to the Alabama UST Regulations Draft ADEM Guidance Prpsed Additins t the Alabama UST Regulatins Yu may have heard abut upcming changes t the undergrund strage tank regulatins (UST regulatins). On Octber 13, 2015 EPA finalized the first

More information

BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE

BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE 1. INTRODUCTION... 3 2. PRECAUTIONS... 3 3. INSPECTION UPON RECEIPT OF GOODS... 4 3.1 GENERAL... 4 3.2 VISIBLE DAMAGE... 4 3.3 CONCEALED DAMAGE...

More information

Headsight HHC JD xx20 series. Combine Manual

Headsight HHC JD xx20 series. Combine Manual Headsight HHC JD xx20 series Cmbine Manual 09010105 Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm

More information

Design Standard - Fume Hoods & Fume Hood Exhausts

Design Standard - Fume Hoods & Fume Hood Exhausts 1.0 Intrductin Design Standard - Fume Hds & Fume Hd Exhausts The fume hd is the primary cntrl device in mst labratries fr prtecting emplyees and students frm expsure t hazardus chemicals. It is als an

More information

How to Sweat (Solder) Copper Pipe By See Jane DrillTM Copyright 2013, All Rights Reserved

How to Sweat (Solder) Copper Pipe By See Jane DrillTM Copyright 2013, All Rights Reserved Hw t Sweat (Slder) Cpper Pipe By See Jane DrillTM Cpyright 2013, All Rights Reserved Objective T learn hw t attach pieces f cpper pipe by sweating r sldering the metal tgether. This is a helpful skill

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Observer Zning Panel ZONE0101ZP6 These instructins must be read and understd cmpletely befre attempting installatin Safety Labeling and Signal Wrds DANGER, WARNING, CAUTION, and

More information

Temporary Use and Vendor Stand Online Permit Submittal

Temporary Use and Vendor Stand Online Permit Submittal Temprary Use and Vendr Stand Online Permit Submittal A Temprary Use Permit is an pen-air small business that is there fr a limited time fr the uses listed belw. Temprary Use Duratin Extensin Agricultural

More information

Drying ovens, incubators, cooled incubators. Drying ovens, incubators, cooled incubators

Drying ovens, incubators, cooled incubators. Drying ovens, incubators, cooled incubators Drying vens, incubatrs, cled incubatrs Drying vens, incubatrs, cled incubatrs STD versin All the units in the STD versin are equipped with a PID micrprcessr cntrller with an LCD graphic display and illuminated

More information

EP12M248 7 Stage Automatic Smart Battery Charger, Desulphuration& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

EP12M248 7 Stage Automatic Smart Battery Charger, Desulphuration& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL EP12M248 7 Stage Autmatic Smart Battery Charger, Desulphuratin& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1

More information

WELCOME. WEB LOCATION Los Angeles, CA

WELCOME. WEB   LOCATION Los Angeles, CA WELCOME Thank yu fr chsing AC Infinity. We are cmmitted t prduct quality and friendly custmer service. If yu have any questins r suggestins, please dn t hesitate t cntact us. Visit www.acinfinity.cm and

More information

INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS

INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS Parts UHO Pump (Special High Output) 3 Qt Reservir 10 Ft High Pressure Tubing 3 Ft Wire Lm 18 1/8 Silicne

More information

SAE Eco-Marathon. By Travis Moore, Nikolaus Glassy, John Gamble, and Abdulrahman Alshodokhi Team 14

SAE Eco-Marathon. By Travis Moore, Nikolaus Glassy, John Gamble, and Abdulrahman Alshodokhi Team 14 SAE Ec-Marathn By Travis Mre, Niklaus Glassy, Jhn Gamble, and Abdulrahman Alshdkhi Team 14 Prject Frmulatin and Prject Plan Dcument Submitted twards partial fulfillment f the requirements fr Mechanical

More information

INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL

INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL Parts UHO Pump (Ultra High Output) 3 Qt Reservir 10 ft High Pressure Tubing 3 ft Black Wire

More information

PSS INSTALLATION INSTRUCTIONS

PSS INSTALLATION INSTRUCTIONS PSS INSTALLATION INSTRUCTIONS Imprtant - Read Befre Starting! Befre starting yur installatin carefully read the fllwing warnings and instructins. Failure t prperly fllw the warnings and instructins culd

More information

SWP200 SERIES: PHOTOVOLTAIC KITS FOR WATER PUMPING

SWP200 SERIES: PHOTOVOLTAIC KITS FOR WATER PUMPING File ref.: KITswp0_ing Rev. 00-04.0 SWP0 SERIES: PHOTOVOLTAIC KITS FOR WATER PUMPING Water is ne f the few resurces, withut which mankind cannt d. Man has t supply with certain quantities f water in rder

More information

Madrid Science Program Registration

Madrid Science Program Registration Madrid Science Prgram Registratin Students wh will be taking classes at the Universidad Autónma de Madrid (UAM) must 1. submit the registratin material, 2. cmplete the UAM nline registratin (SIGMA) and

More information

Generator/Loadbank Quick Connection Switchboard

Generator/Loadbank Quick Connection Switchboard / Generatr/Ladbank Quick Cnnectin Switchbard FS2-Series Generatr/Ladbank Quick Cnnectin Slutins Brchure www.apt-pwer.cm 433 N. 36 th Street Lafayette, IN 47905 (765) 446-2343 ALN: 516 Rev. 01 Standard

More information

NetSure. 400V DC Power Solutions

NetSure. 400V DC Power Solutions TM NetSure 400V DC Pwer Slutins WE ARE VERTIV Vertiv, frmerly Emersn Netwrk Pwer, designs, builds,and services missin critical technlgies that enable vital applicatins fr data centers, cmmunicatin netwrks,

More information

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles Safe Handling f High Vltage Electrical cmpnents in Electrical End f Life Vehicles The fllwing infrmatin is extracted frm the dcument Safe Handling f High Vltage Electrical cmpnents in Electrical End f

More information

EDBRO TRAILER INCLINOMETER

EDBRO TRAILER INCLINOMETER EDBRO TRAILER INCLINOMETER TINC01 (12V AND 24V VERSIONS) Installatin & Operating Instructins E5541 rev 5 (Sept 2015) Edbr PLC Nelsn Street, Bltn BL3 2JJ UK Tel: +44 (0) 120 4528888 Fax: +44 (0) 120 4531957

More information

DRIVER S/OWNER OPERATOR APPLICATION FOR EMPLOYMENT

DRIVER S/OWNER OPERATOR APPLICATION FOR EMPLOYMENT Tll: 1-800-265-8789 Tel: 905-457-8789 Fax: 905-457-8372 careers@travelers.ca * www.travelers.ca * DRIVER S/OWNER OPERATOR APPLICATION FOR EMPLOYMENT Please read and sign page 6 befre cmpleting the fllwing

More information

TOTALINE DUAL FUEL HEAT PUMP. Installation Instructions 3 HEAT - 2 COOL DIGITAL THERMOSTAT MODEL P COOL

TOTALINE DUAL FUEL HEAT PUMP. Installation Instructions 3 HEAT - 2 COOL DIGITAL THERMOSTAT MODEL P COOL DIGITAL THEMSTAT MDEL P374-1500 Installatin Instructins 6:03 Am HEAT MULTI-STAGE 3 HEAT - 2 DUAL FUEL HEAT PUMP PGAMMABLE TTALINE eplacement mpnents Divisin arrier rpratin 7/99 Table f ntents PEPAATIN

More information

LN products. Contents. LN Cabinets for LAN applications. LN Enclosures. LN Open Racks

LN products. Contents. LN Cabinets for LAN applications. LN Enclosures. LN Open Racks LN prducts LN Cabinets fr LAN applicatins The LN cabinets is lightweight and a gd chice fr slutins where the required lad-bearing capacity is nt great and the applicatins are installed indrs. The cabinets

More information

QuickServer Start-up Guide

QuickServer Start-up Guide QuickServer Start-up Guide FS-QS-1010/1011/12X0/12X1 APPLICABILITY & EFFECTIVITY Effective for all systems manufactured after August 2013 Kernel Version: 6.10 Document Revision: 1 QuickServer Start-up

More information

PRE-PLANNING & DELIVERY GUIDE

PRE-PLANNING & DELIVERY GUIDE TM PRE-PLANNING & DELIVERY GUIDE Need Assistance? Call 1-888-329-4847 PRE-DELIVERY Spa Delivery Preparatin Yur spa delivery will arrive CURBSIDE at the specified delivery address yu prvided at the time

More information

3000-series Remote Start System with Keyless Entry. Owner's Guide

3000-series Remote Start System with Keyless Entry. Owner's Guide 3000-series Remte Start System with Keyless Entry Owner's Guide Cngratulatins Cngratulatins n the purchase f yur state-f-the-art remte start system with keyless entry. Reading this Owner s Guide prir

More information

Traffic Logix SafePace 450 (Full & Compact) Radar Speed Signs Product Specifications Version 1.6

Traffic Logix SafePace 450 (Full & Compact) Radar Speed Signs Product Specifications Version 1.6 Traffic Lgix SafePace 450 (Full & Cmpact) Radar Speed Signs Prduct Specificatins Versin 1.6 2014-2016 Traffic Lgix Crpratin www.tapcnet.cm 5100 West Brwn Deer Rad Brwn Deer, WI 53223 1 Table f Cntents

More information

GLOBAL LIFT CORP. Owner s Manual. Superior Series Proformance Series S-350 / P-375

GLOBAL LIFT CORP. Owner s Manual. Superior Series Proformance Series S-350 / P-375 GLOBAL LIFT CORP Owner s Manual Superir Series Prfrmance Series S-350 / P-375 684 N Prt Crescent Rd Suite C Bad Axe, MI 48413 Tll Free: 866-712-0606 Fax: 989-269-5902 www.glballiftcrp.cm Page 1 SUPERIOR

More information