2 Pneumatics. Auto Switch Guide. Applicable Cylinder Series 1 CDA2-X1184 MDB-X1184 CDQ2-XB14 CDG5 S HYDB CDJ5 S CDJP2 CDQM MDU CDQS HYDQ CDJ2 MDB1

Size: px
Start display at page:

Download "2 Pneumatics. Auto Switch Guide. Applicable Cylinder Series 1 CDA2-X1184 MDB-X1184 CDQ2-XB14 CDG5 S HYDB CDJ5 S CDJP2 CDQM MDU CDQS HYDQ CDJ2 MDB1"

Transcription

1 Best 2 Pneumatics Auto Switch Guide Applicable Cylinder Series 1 Cylinder series CDJP2 CDJ2 CDM2 CDG1 MDB MDB-X1184 MDB1 CDA2 CDA2-X1184 CDS1 CDS2 CDUJ CDU CDQS CDQ2 CDQ2-XB14 RDQ CDQM MDU CDJ S CDG S HYDB HYDQ Solid state auto switches Reed auto switches Bore size D-H7 D-H7C D-H7BAL D-H7NF D-H7W D-G/K D-GBAL D-G9F D-GNTL D-GW/K9W D-G9/K9 D-G9A/K9A D-F7/J7 D-J79C D-F79F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F/J D-FBAL D-FW/J9W D-F9F D-FNTL D-G9C/K9C D-M9 D-M9V D-M9W D-M9WV D-M9AL/M9AVL D-Y/Y6/Y7/Y7V D-Y7BAL D-Y7W/Y7WV D-M D-MW D-MTL D-P4DWL D-F9G/H D-Y7G/H D-GNBL D-F7NJL D-F6 D-F8 D-C7/C8 D-C7C/C80C D-B/B6 D-B9W D-A/A4 D-AA/A44A D-AC/A44C D-A7/A8 D-A7H/A80H D-A7C/A80C D-A79W D-A/A6 D-A9W D-A9 D-A9V D-E7A/E80A D-Z7/Z8 D-P7 D-B ø4 ø6, ø10, ø16 ø6 ø10, ø16 ø20 to ø40 ø20 to ø6 ø80, ø100 ø2 to ø12 ø40 to ø100 ø2 to ø12 ø40 to ø100 ø40 to ø100 ø12 to ø200 ø12 to ø160 ø6 to ø10 ø6 to ø2 ø12 to ø2 ø12 to ø2 ø2 to ø100 ø12 to ø160 ø180 to ø200 ø16 to ø6 ø20, ø2 ø2 to ø0 ø12 to ø2 ø2 to ø100 ø2 to ø6 ø10, ø16 ø20 to ø100 ø20 to ø6 ø80, ø100 ø20 to ø6 Actuator page reference (: Best Pneumatics) P.21 P.9 P.12 P.219 P.28 P.11 P.29 P. P.116 P.409 P.447 P.46 P.479 P.47 P.99 P.1410 P.771 P.791 P.807 P.8 P.84 P

2 Cylinder series HYDC HYDG MY1B MY1M MY1C Applicable Cylinder Series 1 MY1H MY1HT MY1W MY2 MY CYR CDY1S/CY1L CY1H CY1F CYP MXH MXU MXS MXQ MXF MXW MXJ MXP MXY MTS MGJ Auto Switch Guide Solid state auto switches Reed auto switches Bore size D-H7 D-H7C D-H7BAL D-H7NF D-H7W D-G/K D-GBAL D-G9F D-GNTL D-GW/K9W D-G9/K9 D-G9A/K9A D-F7/J7 D-J79C D-F79F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F/J D-FBAL D-FW/J9W D-F9F D-FNTL D-G9C/K9C D-M9 D-M9V D-M9W D-M9WV D-M9AL/M9AVL D-Y/Y6/Y7/Y7V D-Y7BAL D-Y7W/Y7WV D-M D-MW D-MTL D-P4DWL D-F9G/H D-Y7G/H D-GNBL D-F7NJL D-F6 D-F8 D-C7/C8 D-C7C/C80C D-B/B6 D-B9W D-A/A4 D-AA/A44A D-AC/A44C D-A7/A8 D-A7H/A80H D-A7C/A80C D-A79W D-A/A6 D-A9W D-A9 D-A9V D-E7A/E80A D-Z7/Z8 D-P7 D-B ø2 to ø6 ø2 to ø6 ø10 to ø20 ø2 to ø100 ø16, ø20 ø2 to ø6 ø16, ø20 ø2 to ø6 ø10 to ø20 ø2 to ø40 ø0, ø6 ø16, ø20 ø2 to ø6 ø16, ø2, ø40 ø16, ø2, ø40, ø6 ø6 to ø20 ø2 to ø6 ø6 to ø40 ø10 to ø2 ø10, ø1, ø2 ø1, ø2 ø6 to ø20 ø6 to ø16 ø6 to ø2 ø6 to ø2 ø8 to ø20 ø8 to ø2 ø4, ø6, ø8 ø6 to ø16 ø6, ø10, ø12, ø16 ø8 to ø40 ø6, ø10 D- Actuator page reference (: Best Pneumatics) P.867 P.87 P.94 P.107 P.108 P.1121 P.1178 P.1189 P.121 P.1229 P.1249 P.1 P. P.49 P.87 P.1 P.147 P.169 P.189 P.21 P.229 P.2 126

3 Best 2 Pneumatics Auto Switch Guide Applicable Cylinder Series 2 Cylinder series MGP MGQ MGG MGC MGF MGZ MGT CX2 CDBXW CDPXW CXT CXSJ CXS CDLJ2 CDLM2 CDLG1 CDL1 MLGC CDNG MDNB CDNA CDNS CDLS CDLQ RDLQ MDLU MLGP Solid state auto switches Reed auto switches Bore size D-H7 D-H7C D-H7BAL D-H7NF D-H7W D-G/K D-GBAL D-G9F D-GNTL D-GW/K9W D-G9/K9 D-G9A/K9A D-F7/J7 D-J79C D-F79F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F/J D-FBAL D-FW/J9W D-F9F D-FNTL D-G9C/K9C D-M9 D-M9V D-M9W D-M9WV D-M9AL/M9AVL D-Y/Y6/Y7/Y7V D-Y7BAL D-Y7W/Y7WV D-M D-MW D-MTL D-P4DWL D-F9G/H D-Y7G/H D-GNBL D-F7NJL D-F6 D-F8 D-C7/C8 D-C7C/C80C D-B/B6 D-B9W D-A/A4 D-AA/A44A D-AC/A44C D-A7/A8 D-A7H/A80H D-A7C/A80C D-A79W D-A/A6 D-A9W D-A9 D-A9V D-E7A/E80A D-Z7/Z8 D-P7 D-B ø12 to ø100 ø12 to ø100 ø20 to ø6 ø80 to ø100 ø20 to ø0 ø40, ø6, ø100 ø20 to ø80 ø6 to ø100 ø10, ø1, ø2 ø10 ø16 to ø2 ø10 to ø2 ø12 to ø2 ø2, ø40 ø6, ø10 ø6 to ø2 ø16 ø20 to ø40 ø20 to ø40 ø40 to ø100 ø12 to ø160 ø20 to ø40 ø20 to ø40 ø2 to ø100 ø40 to ø100 ø12 to ø160 ø12 to ø200 ø20 to ø2 ø2 to ø100 ø2 to ø6 ø2 to ø0 ø20 to ø100 Actuator page reference (: Best Pneumatics) P.26 P.7 P. P.91 P.409 P.421 P.449 P.461 P.47 P.21 P. P.9 P.67 P.669 P.69 P.72 P.77 P.781 P.809 P.89 P.86 P

4 Cylinder series ML1C REAR REAS REAL REAH REBR Applicable Cylinder Series 2 REBH REC CDQSY CDQ2Y CDM2Y CDG1Y CDA2Y CDJ2X CDUX CDQSX CDQ2X CDM2X RHC RZQ MK/MK2 MK2T CKQ CLKQ CKG1 CKP1 CLK2G Auto Switch Guide Solid state auto switches Reed auto switches Bore size D-H7 D-H7C D-H7BAL D-H7NF D-H7W D-G/K D-GBAL D-G9F D-GNTL D-GW/K9W D-G9/K9 D-G9A/K9A D-F7/J7 D-J79C D-F79F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F/J D-FBAL D-FW/J9W D-F9F D-FNTL D-G9C/K9C D-M9 D-M9V D-M9W D-M9WV D-M9AL/M9AVL D-Y/Y6/Y7/Y7V D-Y7BAL D-Y7W/Y7WV D-M D-MW D-MTL D-P4DWL D-F9G/H D-Y7G/H D-GNBL D-F7NJL D-F6 D-F8 D-C7/C8 D-C7C/C80C D-B/B6 D-B9W D-A/A4 D-AA/A44A D-AC/A44C D-A7/A8 D-A7H/A80H D-A7C/A80C D-A79W D-A/A6 D-A9W D-A9 D-A9V D-E7A/E80A D-Z7/Z8 D-P7 D-B ø2 to ø40 ø10, ø1, ø20 ø2 to ø40 ø10 to ø40 ø10 to ø40 ø10 to ø2 ø1 ø2, ø2 ø1 to ø2 ø20 to ø40 ø12 to ø2 ø2 to ø100 ø20 to ø40 ø20 to ø6 ø80, ø100 ø40 to ø100 ø10 to ø16 ø10 to ø2 ø12 to ø2 ø2 to ø100 ø20 to ø40 ø20 to ø6 ø80 to ø100 ø2 to ø6 ø20 to ø6 ø12, ø16, ø2 to ø6 ø20 to ø6 ø0 ø0 ø40 to ø6 ø40 to ø6 ø2 to ø6 D- Actuator page reference (: Best Pneumatics) P.909 P.92 P.102 P.1047 P.1111 P.119 P.1217 P.12 P.126 P.117 P

5 Best 2 Pneumatics Auto Switch Guide Applicable Cylinder Series Cylinder series CLK2P RSDQ RSDG RSH MIS/MIW CEP1 CE1 CE2 ML2B CVQ CDVJ CDVJ CDVM CDVMK CDVM CDVMK CDV CDVK CDVS1 CDVS1K MVGQ Solid state auto switches Reed auto switches Bore size D-H7 D-H7C D-H7BAL D-H7NF D-H7W D-G/K D-GBAL D-G9F D-GNTL D-GW/K9W D-G9/K9 D-G9A/K9A D-F7/J7 D-J79C D-F79F D-F7BAL D-F7BAVL D-F7V D-F7NTL D-F7W (V) D-F/J D-FBAL D-FW/J9W D-F9F D-FNTL D-G9C/K9C D-M9 D-M9V D-M9W D-M9WV D-M9AL/M9AVL D-Y/Y6/Y7/Y7V D-Y7BAL D-Y7W/Y7WV D-M D-MW D-MTL D-P4DWL D-F9G/H D-Y7G/H D-GNBL D-F7NJL D-F6 D-F8 D-C7/C8 D-C7C/C80C D-B/B6 D-B9W D-A/A4 D-AA/A44A D-AC/A44C D-A7/A8 D-A7H/A80H D-A7C/A80C D-A79W D-A/A6 D-A9W D-A9 D-A9V D-E7A/E80A D-Z7/Z8 D-P7 D-B ø40 to ø6 ø12 ø16, ø20 ø2, ø40, ø0 ø40, ø0 ø20 to ø80 ø8, ø12, ø20, ø2, ø2 ø12, ø20 ø12, ø20 ø2 to ø6 ø40 to ø100 ø2 to ø40 ø2, ø40 ø10, ø16 ø10, ø16 ø20 to ø40 ø20 to ø40 ø20 to ø40 ø20 to ø40 ø40 to ø100 ø40 to ø6 ø40 to ø100 ø40 to ø6 ø12 to ø100 Actuator page reference (: Best Pneumatics) P.144 P.171 P.187 P.1401 P.141 P.147 P.148 P.10 P.127 P.142 P.16 P.1604 P.1624 P

6 Applicable Cylinder Series /Auto Switch Variations 1 Auto Switch Variations 1 Auto switch Function Type mounting style Electrical entry Page General purpose auto switches Solid state Band Rail Tie-rod Direct Connector Terminal conduit Connector Terminal conduit D-H7A1/H7A2/H7B D-G9/GP/K9 D-H7C D-G9/K9 D-G9A/K9A D-F79/F7P/J79 D-F7NV/F7PV/F7BV D-J79C D-F9/FP/J9/J1 D-G9C/K9C D-M9N/M9P/M9B * D-M9NV/M9PV/M9BV * D-F8N/F8P/F8B D-F9G/F9H * D-Y9A/Y9B/Y7P ** D-Y69A/Y69B/Y7PV ** D-Y7G/Y7H ** D-MN/MP/MB D-C7/C76/C80 12 D-B/B4/B64 1 Connector D-C7C/C80C 14 Band D-A/A4 1 Terminal conduit D-AA/A4A 16 DIN terminal D-A44 1 D-A44A 16 D-A72/A7/A80 17 Rail D-A72H/A7H/A76H/A80H 18 Tie-rod Connector Terminal conduit DIN terminal D-A7C/A80C D-A/A4/A6/A64/A67 D-AC/A4C D-A44C D-A90/A9/A96 * 142 Direct D-A90V/A9V/A96V * D-Z7/Z76/Z80 ** 14 D-E7A/E76A/E80A 144 * These auto switches can be mounted with a band (except D-A9V and M9V), a rail, a tie-rod or a square groove when auto switch mounting brackets are used. Refer to pages 16, 160, 164, 168 and 169 for details. ** These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. Refer to page 167 for details. Reed Auto Switch Guide Band mounting Rail mounting Tie-rod mounting Direct mounting D- 1269

7 Best 2 Pneumatics Auto Switch Guide Auto Switch Variations 2 Auto switch Function Type mounting style Electrical entry Page Band D-H7NW/H7PW/H7BW D-G9W/GPW/K9W color indication Solid state Rail Tie-rod Direct D-F79W/F7PW/J79W D-F7NWV/F7BWV D-F9W/FPW/J9W D-M9NW/M9PW/M9BW * D-M9NWV/M9PWV/M9BWV * D-Y7NW/Y7PW/Y7BW ** D-Y7NWV/Y7PWV/Y7BWV ** D-MNW/MPW/MBW Band Rail Tie-rod D-B9W D-A79W D-A9W * These auto switches can be mounted with a band (except D-M9WV and M9AVL), a rail, a tie-rod or a square groove when auto switch mounting brackets are used. Refer to pages 16, 160, 164, 168 and 169 for details. ** These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. Refer to page 167 for details. Reed Easily identifiable, stable operating position Mounting positions can be set easily. Optimal operating positions can be set while watching the lights. Displacement of the detecting position can be visually checked. Trouble caused by incorrect detection can be prevented beforehand. ON Red Green Stable operating position Operating position 2-color indication Red OFF Red Green Red Band mounting Rail mounting Tie-rod mounting Direct mounting 1270

8 The diagnostic output signal can be detected in an unsteady detecting area. Water resistant (coolant) type Hygienic type Band Rail Tie-rod Band Rail Tie-rod Direct Auto Switch Variations 2 Auto switch Function Type mounting style Electrical entry Page 2-color indication auto switch with diagnostic output Water resistant 2-color indication auto switch Solid state Solid state D-H7NF D-G9F D-F79F D-F9F D-H7BAL D-GBAL D-F7BAL D-F7BAVL D-FBAL D-M9AL D-M9AVL D-Y7BAL Auto Switch Guide Hygienic With built-in OFF-delay timer (200 ms) Auto switch with timer Solid state Solid state Direct D-F6N/F6P/F6B 112 Band Rail Tie-rod Direct Can be used in an environment where magnetic field disturbances are generated. D-GNTL D-F7NTL D-FNTL D-MNTL/MPTL Magnetic field resistant auto switch Solid state Reed Rail Rod Can be used in a high-temperature environment (Max. 10 C). D-P4DWSC/P4DWSE D-P4DWL D-P79WSE D-P Heat resistant auto switch Solid state Reed Sensor unit: Rail Amplifier unit: DIN rail Band D-F7NJL 119 Terminal conduit D-B0/1/ 11 D-B0J/1J/J Wide range detection type Wide range detection auto switch Solid state Simple workpiece recognition is possible. Band D-GNBL 120 Trimmer auto switch Solid state Rail Direct D-F7K/Y7K (D-RNK/RPK is required.) 121 * These auto switches can be mounted with a band (except D-M9WV and M9AVL), a rail, a tie-rod or a square groove when auto switch mounting brackets are used. Refer to pages 16, 160, 164, 168 and 169 for details. ** These auto switches can be mounted with a tie-rod when auto switch mounting brackets are used. Refer to page 167 for details. 2-color indication type with diagnostic output Water resistant 2-color indication type Hygienic With timer Magnetic field resistant Heat resistant Wide range detection Trimmer auto switch D- Sensor unit Amplifier unit 1271

9 Prior to Use Auto Switches Common Specifications 1 Auto Switches Common Specifications Specific Product Precautions Refer to the Auto Switch Precautions on pages 8 to 11 before using auto switches. Type Leakage current Operating time Impact resistance Insulation resistance Reed auto switch Solid state auto switch None -wire: 100 μa or less, 2-wire: 0.8 ma or less 1.2 ms 1 ms or less () 00 m/s m/s 2 (4) 0 MΩ or more at 00 VDC Mega (Between lead wire and case) Withstand voltage 100 VAC for 1 minute (1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Ambient temperature 10 to 60 C Enclosure IEC6029 IP67 (2) 1) Electrical entry: Connector type (A7C/A80C/C7C/C80C): 1000 VAC/min. (Between lead wire and the case) 2) The terminal conduit type (D-A/AA/AC/G9/G9A/G9C/K9/K9A/K9C), DIN terminal type (D-A44/A44A/A44C) and heat resistant auto switch (D-F7NJL) conform to IEC6029 IP6. The trimmer type amplifier section (D-RK) conforms to IP40. ) Excluding the solid state auto switches with a timer (D-MTL/GNTL/F7NTL/FNTL types) and magnetic field resistant 2-color indication solid state auto switch (D-P4DWL). The operating time for D-J1 is 2 ms or less and for D-P4DWL is 40 ms or less. 4) 980 m/s 2 for the trimmer type sensor section, 98 m/s 2 for the amplifier section. Lead Wire indication (Example) D-M9BW L Nil M L Z N 0. m 1 m m m None Applicable for the connector type (D-C) only. Note 1) Z: m Applicable auto switches Reed auto switch: D-B/B4, D-C7(C)/C80C, D-A7(C)(H)/A80C, D-A/A4, D-Z7, D-90/97/90A/9A Solid state auto switch: Manufactured upon receipt of order as standard. Note 2) The standard lead wire length for solid state auto switches with a timer, water resistant 2-color indication solid state auto switches, wide range detection type solid state auto switches, heat resistant 2-color indication solid state auto switches and trimmer auto switches is m. (0. m is not available.) Note ) The standard lead wire length for magnetic field resistant 2-color indication solid state auto switches is m or m. (0. m is not available.) Note 4) 1 m (M): D-M9(W)(V) only Solid state auto switch oil resistant flexible cabtire cord indication Add a -61 at the end of the part number for the solid state auto switch flexible cord except D-Y9, D-Y69, D-Y7, D-M9/M9V, and D-M9W/M9WV. (Example) D-F7PL- 61 Flexible specification (D-Y9, D-Y69, D-Y7 and D-M9 series use flexible lead wire as standard. ) Lead wires with a connector indication Part No. of Lead Wires with Connectors (Applicable only for connector type) Model D-LC0 D-LC0 D-LC0 0. m m m 0. m 1 m m m Tolerance ±1 mm ±0 mm ±90 mm ±10 mm 1272

10 Prior to Use Auto Switches Common Specifications 2 Specific Product Precautions Refer to the Auto Switch Precautions on pages 8 to 11 before using auto switches. Auto Switch Hysteresis Hysteresis is the distance between the position at which piston movement operates an auto switch to the position at which reverse movement turns the switch off. This hysteresis is included in part of the operating range (one side). Auto switch Switch operating position (ON) Hysteresis Reed auto switch: 2 mm or less Solid state auto switch: 1 mm or less Switch operating position (OFF) Note) Note) Hysteresis may fluctuate due to the operating environment. Please contact SMC if hysteresis causes an operational problem. Contact Protection Box: CD-P11, CD-P12 <Applicable switch models> D-A7/A8, D-A7H/A80H, D-A7C/A80C, D-C7/C8, D-C7C/C80C, D- E7A, E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, and D-A79W type The auto switches above do not have a built-in contact protection circuit. A contact protection box is not required for solid state auto switches due to their construction. q Where the operation load is an inductive load. w Where the wiring length to load is greater than m. e Where the load voltage is 100/200 VAC. Therefore, use a contact protection box with the switch for any of the above cases: The contact life may be shortened (due to permanent energizing conditions.) D-A72(H) must be used with the contact protection box regardless of load types and lead wire length since it is greatly affected by loads. (Where the load voltage is 110 VAC) When the load voltage is increased by more than 10% to the rating of applicable auto switches (except D-A7C/A80C/C7C/C80C/90/97/A79W) above, use a contact protection box (CD-P11) to reduce the upper limit of the load current by 10% so that it can be set within the range of the load current range, 110 VAC. Even for the built-in contact protection circuit type (D-A4[A][C], D- A44[A][C], D-A4/A64, D-A9W, D-B9W), use the contact protection box when the wiring length to load is very long (over 0 m) and PLC (Programmable Logic Controller) with a large inrush current is used. Contact Protection Box Specifications Part no. CD-P11 CD-P VAC or less 200 VAC Max. load current 2 ma 12. ma 24 VDC 0 ma Auto switch connection side 0. m Load connection side 0. m Contact Protection Box Internal Circuit CD-P11 CD-P12 Surge absorber Zener diode Choke coil Choke coil Contact Protection Box/ ~ (+) ( ) Contact Protection Box Connection To connect a switch unit to a contact protection box, connect the lead wire from the side of the contact protection box marked SWITCH to the lead wire coming out of the switch unit. Keep the switch as close as possible to the contact protection box, with a lead wire length of no more than 1 meter. D- 127

11 Prior to Use Auto Switches Connection and Example Basic Wiring Solid state -wire, NPN Solid state -wire, PNP 2-wire (Solid state) 2-wire (Reed switch) Main curcuit Load Main curcuit Load Main curcuit Load Indicator protection circuit, etc. Load ~ (Power supply for switch and load are separate) Main curcuit Load Main curcuit Load Indicator protection circuit, etc. Load ~ Example of Connection with PLC (Programmable Logic Controller) Sink input specifications -wire, NPN 2-wire Input Auto switch COM PLC internal circuit Input Source input specifications -wire, PNP Auto switch COM PLC internal circuit 2-wire Input Input Connect according to the applicable PLC input specifications, as the connection method will vary depending on the PLC input specifications. Auto switch Auto switch COM PLC internal circuit COM PLC internal circuit Example of AND (Series) and OR (Parallel) Connection -wire AND connection for NPN output (Using relays) Auto switch 1 Auto switch 2 Relay Relay Load Relay contact AND connection for NPN output (Performed with auto switches only) Auto switch 1 Auto switch 2 Load OR connection for NPN output Auto switch 1 Auto switch 2 Load 2-wire 2-wire with 2-switch AND connection Auto switch 1 Auto switch 2 Load When two auto switches are connected in series, a load may malfunction because the load voltage will decline when in the ON state. The indicator lights will light up when both of the auto switches are in the ON state. at ON = Power supply voltage Residual voltage x 2 pcs. = 24 V 4 V x 2 pcs. = 16 V Example: Power supply is 24 VDC in auto switch is 4 V The indicator lights will light up when both auto switches are turned ON. 2-wire with 2-switch OR connection (Solid state auto switch) When two auto switches Load are connected in parallel, Auto switch 1 malfunction may occur because the load voltage will increase when in the OFF state. Auto switch 2 at OFF = Leakage current x 2 pcs. x Load impedance = 1 ma x 2 pcs. x kω = 6 V Example: Load impedance is kω. Leakage current from auto switch is 1 ma. (Reed auto switch) Because there is no current leakage, the load voltage will not increase when turned OFF. However, depending on the number of auto switches in the ON state, the indicator lights may sometimes grow dim or not light up, due to the dispersion and reduction of the current flowing to the auto switches.

12 Best 2 Pneumatics Auto Switch Guide Solid State Auto Switches P.1277 Auto Switch Guide General Purpose Type Band, Rail, Tie-rod, Direct Mounting P Color Indication Type Band, Rail, Tie-rod, Direct Mounting P Color Indication Type with Diagnostic Output Band, Rail, Tie-rod Mounting P.102 Water Resistant 2-Color Indication Type Band, Rail, Tie-rod, Direct Mounting P.106 Hygienic Direct Mounting P.112 With Timer Band, Rail, Tie-rod, Direct Mounting P.11 Magnetic Field Resistant 2-Color Indication Type Rail Mounting P.117 Heat Resistant 2-Color Indication Type Rail Mounting P.119 Wide Range Detection Type Band Mounting P.120 Trimmer Auto Switch Rail, Direct Mounting P.121 Made to Order Specifications P.128 Reed Auto Switches P.11 General Purpose Type Band, Rail, Tie-rod, Direct Mounting P.12 2-Color Indication Type Band, Rail, Tie-rod Mounting P.14 Magnetic Field Resistant 2-Color Indication Type Rod Mounting P.148 Heat Resistant Band Mounting P.11 D- Data P.1 127

13 1276

14 Solid State Auto Switches General Purpose Type, 2-color Indication Type, 2-color Indication Type with Diagnostic Output, Water Resistant 2-color Indication Type, Hygienic Type, Timer Equipped Type, Magnetic Field Resistant Type, Heat Resistant Type, Wide Range Detection Type, Trimmer Auto Switch Auto switch Type Function mounting style Electrical entry Page General purpose Band Rail Tie-rod Direct Connector Terminal conduit Connector Terminal conduit D-H7A1/H7A2/H7B D-G9/GP/K9 D-H7C D-G9/K9 D-G9A/K9A D-F79/F7P/J79 D-F7NV/F7PV/F7BV D-J79C D-F9/FP/J9/J1 D-G9C/K9C D-M9N/M9P/M9B D-M9NV/M9PV/M9BV D-F8N/F8P/F8B D-F9G/F9H D-Y9A/Y9B/Y7P D-Y69A/Y69B/Y7PV D-Y7G/Y7H D-MN/MP/MB Solid State Auto Switch 2-color indication 2-color indication with diagnostic output Water resistant 2-color indication Hygienic D-H7NW/H7PW/H7BW 1294 Band D-G9W/GPW/K9W 129 Rail D-F79W/F7PW/J79W 1296 D-F7NWV/F7BWV 1297 Tie-rod D-F9W/FPW/J9W 1298 D-M9NW/M9PW/M9BW D-M9NWV/M9PWV/M9BWV 1299 Direct D-Y7NW/Y7PW/Y7BW D-Y7NWV/Y7PWV/Y7BWV 100 D-MNW/MPW/MBW 101 Band Rail Tie-rod Band Rail Tie-rod Direct D-H7NF D-G9F D-F79F D-F9F D-H7BAL D-GBAL F7BAL F7BAVL D-FBAL D-M9PAL/M9NAL/M9BAL D-M9PAVL/M9NAVL/M9BAVL D-Y7BAL Direct D-F6N/F6P/F6B 112 With timer Magnetic field resistance Band Rail Tie-rod Direct Rail D-GNTL D-F7NTL D-FNTL D-MNTL/MPTL D-P4DWSC/P4DWSE D-P4DWL D- Heat resistant Sensor section: Rail Amplifier section: DIN rail D-F7NJL 119 Wide range detection Trimmer Auto Switch Band Rail Direct D-GNBL 120 D-F7K/Y7K

15 Solid State Auto Switch Band Mounting Style D-H7A1/D-H7A2/D-H7B D-H7 (With indicator light) D-H7A1 D-H7A2 D-H7B Wiring type -wire 2-wire Output type NPN PNP Power supply voltage Current consumption IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 24 VDC Relay, PLC Load current 28 VDC or less 40 ma or less 1. V or less 80 ma or less 24 VDC (10 to 28 VDC) to 40 ma (0.8 V or less 0.8 V or less 4 V or less at 10 ma load current) Leakage current 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-H7A1 (m) 0. D-H7A1 D-H7A2 D-H7B D-H7A2 D-H7B (+) ø. mounting hole ( ) 1278

16 Solid State Auto Switch Band Mounting Style D-G9/D-GP/D-K9 D-G, D-K9 (With indicator light) D-G9 D-GP D-K9 Wiring type -wire 2-wire Output type NPN PNP Power supply voltage Current consumption IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 24 VDC Relay, PLC Load current 28 VDC or less 40 ma or less 1. V or less 80 ma or less 24 VDC (10 to 28 VDC) to 40 ma (0.8 V or less at 10 ma load current) 0.8 V or less 4 V or less Leakage current 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-G9 (m) 0. D-G9 D-GP D-K D-GP D-K9 (+) ø4. mounting hole ( ) D- 1279

17 Solid State Auto Switch Band Mounting Style D-H7C Connector Caution Precautions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. Refer to page 1 for the details. D-H7C (With indicator light) Wiring type Output type Power supply voltage Current consumption Load current Leakage current D-H7C 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Lead wires with a connector may be shipped with switches. D-H7C (+) (m) 0. D-H7C ( ) ø. mounting hole 1280

18 Solid State Auto Switch Band Mounting Style D-G9/D-K9 Terminal conduit Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-G9, D-K9 (With indicator light) D-G9 Wiring type Output type Power supply voltage Current consumption Load current Leakage current -wire NPN IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma of load current) 100 μa or less at 24 VDC Note) Refer to page 1272 for solid state auto switch common specifications. D-K9 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. D-G9 Terminal no. 1 D-G9 D-K9 Lead wire None Terminal no. 2 D-K9 Terminal no. (+) Terminal no. 1 ( ) Terminal no. 2 Tightening gland G (PF) 1/2 (Applicable cable O.D. ø6.8 to ø9.6) D- 1281

19 Solid State Auto Switch Band Mounting Style D-G9A/D-K9A Terminal conduit Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-G9A, D-K9A (With indicator light) D-G9A Wiring type Output type Power supply voltage Current consumption Load current Leakage current -wire NPN IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma of load current) 100 μa or less at 24 VDC Note) Refer to page 1272 for solid state auto switch common specifications. D-K9A 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. D-G9A Terminal no. 1 D-G9A D-K9A Lead wire None Terminal no. 2 Terminal no. D-K9A (+) Terminal no. 1 G (PF) 1/2 (Applicable cable O.D. ø6.8 to ø9.6) Tightening gland ( ) Terminal no

20 Solid State Auto Switch Rail Mounting Style D-F79/D-F7P/D-J79 D-F7, D-J79 (With indicator light) D-F79 Wiring type Output type Power supply voltage Current consumption Load current Leakage current NPN -wire 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma load current) D-F7P PNP IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 80 ma or less 0.8 V or less 100 μa or less at 24 VDC Red LED illuminates when turned ON. D-J79 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-F79 (m) 0. D-F79 D-F7P D-J D-F7P ø.2 mounting hole D-J79 (+) D- ( ) 128

21 Solid State Auto Switch Rail Mounting Style D-F7NV/D-F7PV/D-F7BV Electrical entry: Perpendicular D-F7V (With indicator light) D-F7NV Wiring type Output type Power supply voltage Current consumption Load current Leakage current NPN -wire 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma load current) D-F7PV PNP IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 80 ma or less 0.8 V or less 100 μa or less at 24 VDC Red LED illuminates when turned ON. D-F7BV 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-F7NV (m) 0. D-F7NV D-F7PV D-F7BV D-F7PV ø.2 mounting hole D-F7BV (+) ( ) 1284

22 Solid State Auto Switch Rail Mounting Style D-J79C Connector Caution Precautions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. Refer to page 1 for the details. D-J79C (With indicator light) Wiring type Output type Power supply voltage Current consumption Load current Leakage current D-J79C 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Lead wires with a connector may be shipped with auto switches. D-J79C D-J79C (+) (m) ( ) ø.2 mounting hole D- 128

23 D-F9 D-FP D-J9 Solid State Auto Switch Tie-rod Mounting Style D-F9/D-FP/D-J9/D-J1 (+) D-F, D-J (With indicator light) D-F9 D-FP D-J9 D-J1 Wiring type -wire 2-wire Output type NPN PNP IC circuit, Relay, PLC 24 VDC Relay, PLC AC Relay, PLC Power supply voltage, 12, 24 VDC (4. to 28 VDC) Current consumption 10 ma or less 28 VDC or less 24 VDC (10 to 28 VDC) 80 to 260 VAC Load current 40 ma or less 80 ma or less to 40 ma to 80 ma 1. V or less (0.8 V or less at 0.8 V or less 4 V or less 14 V or less 10 ma load current) Leakage current 100 μa or less at 24 VDC 0.8 ma or less 1 ma or less at 100 VAC at 24 VDC 1. ma or less at 200 VAC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) D-F9/D-FP/D-J9 0. D-F9 D-FP D-J9 D-J (Except D-J1) Mounting hole ( ) D-J1 (~) (~) D-J ø ø D-J

24 Terminal conduit Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-G9C Solid State Auto Switch Tie-rod Mounting Style D-G9C/D-K9C Terminal no. 1 Terminal no. 2 Terminal no. D-G9C, D-K9C (With indicator light) Wiring type Output type Power voltage Current consumption Load current Current leakage D-G9C -wire NPN IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma of load current) 100 μa or less at 24 VDC D-K9C 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. Note) Refer to page 1272 for solid state auto switch common specifications. Applicable bore size D-G9C x M x 0.8 x 12 Hexagon socket head cap bolt D-K9C D-K9C (+) Terminal no. 1 4 x Z Hexagon socket head cap bolt Tightening gland G (PF) 1/2 (Applicable cable O.D. ø6.8 to ø9.6) ( ) Terminal no. 2 D-G9C-4, D-K9C-4 D-G9C-, D-K9C- D-G9C-6, D-K9C-6 D-G9C-8, D-K9C-8 D-G9C-10, D-K9C-10 Applicable bore size C HW H H T T Z M x 0.8 x 16 M x 0.8 x 20 M x 0.8 x 2 D- 1287

25 Solid State Auto Switch Direct Mounting Style D-M9N(V)/D-M9P(V)/D-M9B(V) 2-wire load current is reduced (2. to 40 ma). Flexibility is 1. times greater than the conventional model (SMC comparison). Using flexible cable as standard spec. D-M9, D-M9V (With indicator light) D-M9N D-M9NV D-M9P D-M9PV D-M9B D-M9BV Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Wiring type -wire 2-wire Output type NPN PNP Power supply voltage Current consumption IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 V) 10 ma or less 24 VDC relay, PLC 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 ma or less 2. to 40 ma Leakage current 0.8 V or less at 10 ma (2 V or less at 40 ma) 100 μa or less at 24 VDC 4 V or less 0.8 ma or less Red LED illuminates when turned ON. Lead wires Oilproof flexible heavy-duty vinyl cord: ø2.7 x.2 ellipse, 0.1 mm 2, 2 cores (D-M9B(V)), cores (D-M9N(V), D-M9P(V)) Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Caution Precautions Do not fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. (m) 0. 1 D-M9N(V) D-M9P(V) D-M9B(V) D-M9N, D-M9NV D-M9 2.6 M2. x 4l Slotted set screw D-M9P, D-M9PV 6 D-M9V M2. x 4l Slotted set screw D-M9B, D-M9BV (+) ( )

26 Caution Precautions D-F8N Solid State Auto Switch Direct Mounting Style D-F8N/D-F8P/D-F8B Do not fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. D-F8 (With indicator light) D-F8N Electrical entry direction Perpendicular D-F8P Perpendicular D-F8B Perpendicular Wiring type -wire 2-wire Output type NPN PNP Power supply voltage Current consumption IC circuit, 24 VDC Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 24 VDC relay, PLC Load current 28 VDC or less 40 ma or less 1. V or less 80 ma or less 24 VDC (10 to 28 VDC) 2. to 40 ma (0.8 V or less 0.8 V or less 4 V or less at 10 ma load current) Leakage current 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø2.7, 0. m D-F8N, D-F8P 0.1 mm 2 x cores (,, ) D-F8B 0.18 mm 2 x 2 cores (, ) Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-F8N D-F8P D-F8B D-F8P D-F8N/D-F8P/D-F8B 4. 2 M2. x 4l Slotted set screw ø D-F8B (+) ( ) D- 1289

27 Normally Closed Solid State Auto Switch Direct Mounting Style D-F9G/D-F9H Output signal turns on when no magnetic force is detected. Caution Precautions Do not fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. D-F9G, D-F9H (With indicator light) D-F9G Wiring type Output type Power supply voltage Current consumption Load current Leakage current NPN 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma load current) -wire IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less D-F9H PNP 80 ma or less 0.8 V or less 100 μa or less at 24 VDC Red LED illuminates when detecting nothing. Lead wires Oilproof heavy-duty vinyl cord, ø2.7, 0.1 mm 2, cores (,, ) 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-F9G (m) 0. D-F9G D-F9H D-F9H M2. x 4l Slotted set screw 2 SMC D-F9H NC ø

28 A A D-Y9 B/D-Y69 B/D-Y7P(V) Using flexible cable as standard spec. D-Y9A, D-Y69A Solid State Auto Switch Direct Mounting Style D-Y, D-Y6, D-Y7P, D-Y7PV (With indicator light) Electrical entry direction D-Y9A In-line D-Y69A Perpendicular D-Y7P In-line D-Y7PV Perpendicular D-Y9B In-line D-Y69B Perpendicular Wiring type -wire 2-wire Output type NPN IC circuit, Relay, PLC PNP 24 VDC relay, PLC Power supply voltage Current consumption, 12, 24 VDC (4. to 28 VDC) 10 ma or less Load current 28 VDC or less 40 ma or less 1. V or less 80 ma or less 24 VDC (10 to 28 VDC) to 40 ma (0.8 V or less 0.8 V or less 4 V or less at 10 ma load current) Leakage current 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Red LED illuminates when turned ON. (m) 0. D-Y9B D-Y69B D-Y9A D-Y69A Lead wires Oilproof flexible heavy-duty vinyl cord, ø.4, 0.1 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-Y7P(V) D-Y7P, D-Y7PV D-Y9A/D-Y7P/D-Y9B D-Y69A/D-Y7PV/D-Y69B 2. M2. x 4l Slotted set screw 2. M2. x 4l Slotted set screw D-Y9B, D-Y69B (+) 6.2 SMC 29 ø SMC 27. ø ( ) D- 1291

29 Normally Closed Solid State Auto Switch Direct Mounting Style D-Y7G/D-Y7H Output signal turns on when no magnetic force is detected. Using flexible cable as standard spec. D-Y7G, D-Y7H (With indicator light) D-Y7G Wiring type Output type Power supply voltage Current consumption Load current Leakage current NPN 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma load current) -wire IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less D-Y7H PNP 80 ma or less 0.8 V or less 100 μa or less at 24 VDC Red LED illuminates when detecting nothing. Lead wires Oilproof flexible heavy-duty vinyl cord, ø.4, 0.1 mm 2, cores (,, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-Y7G (m) 0. D-Y7G D-Y7H D-Y7H M2. x 4l Slotted set screw SMC NC ø.4 29 D-Y7G

30 Solid State Auto Switch Direct Mounting Style D-MN/D-MP/D-MB D-M (With indicator light) D-MN Wiring type Output type Power supply voltage Current consumption Load current Leakage current NPN -wire 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma load current) D-MP PNP IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 80 ma or less 0.8 V or less 100 μa or less at 24 VDC Red LED illuminates when turned ON. D-MB 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-MN (m) 0. D-MN D-MP D-MB D-MP D-MB ø mounting hole (+) D- ( ) 129

31 2-Color Indication Type Solid State Auto Switch Band Mounting Style D-H7NW/D-H7PW/D-H7BW The optimum operating position can be determined by the color of the light. (Red Green Red) D-H7NW D-H7W (With indicator light) D-H7NW D-H7PW D-H7BW Wiring type -wire 2-wire Output type NPN PNP IC circuit, Relay, PLC 24 VDC relay, PLC Power supply voltage Current consumption, 12, 24 VDC (4. to 28 VDC) 10 ma or less Load current 28 VDC or less 40 ma or less 1. V or less 80 ma or less 24 VDC (10 to 28 VDC) to 40 ma (0.8 V or less at 10 ma load current) 0.8 V or less 4 V or less Leakage current 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-H7PW (m) 0. D-H7NW D-H7PW D-H7BW D-H7BW 29 (+) 9 ø /Display method ( ) ø. mounting hole Operating range Indication Red Green Red 10. Most sensitive position Optimum operating position 1294

32 The optimum operating position can be determined by the color of the light. (Red Green Red) D-G9W 2-Color Indication Type Solid State Auto Switch Band Mounting Style D-G9W/D-GPW/D-K9W D-GW, D-K9W (With indicator light) D-G9W D-GPW Wiring type Output type Power supply voltage Current consumption Load current Leakage current -wire NPN PNP IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 80 ma or less 1. V or less (0.8 V or less 0.8 V or less at 10 ma load current) 100 μa or less at 24 VDC D-K9W 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-GPW (m) 0. D-G9W D-GPW D-K9W D-K9W (+) ø4. mounting hole ( ) /Display method Operating range D- Indication Red Green Red Optimum operating position 129

33 2-Color Indication Type Solid State Auto Switch Rail Mounting Style D-F79W/D-F7PW/D-J79W The optimum operating position can be determined by the color of the light. (Red Green Red) D-F7W, D-J79W (With indicator light) D-F79W D-F7PW Wiring type Output type Power supply voltage Current consumption Load current Leakage current -wire NPN PNP IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 80 ma or less 1. V or less (0.8 V or less at 10 ma load current) 100 μa or less at 24 VDC 0.8 V or less D-J79W 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. D-F79W Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-F7PW (m) 0. D-F79W D-F7PW D-J79W D-J79W 8 ø.2 mounting hole 1 (+) ( ) /Display method ø Operating range Indication Red Green Red Optimum operating position 1296

34 2-Color Indication Type Solid State Auto Switch Rail Mounting Style D-F7NWV/D-F7BWV Electrical entry: Perpendicular The optimum operating position can be determined by the color of the light. (Red Green Red) D-F7WV (With indicator light) D-F7NWV Wiring type Output type Power supply voltage Current consumption Load current Leakage current -wire NPN IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma load current) D-F7BWV 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-F7NWV (m) 0. D-F7NWV D-F7BWV D-F7BWV (+) ø.2 mounting hole ( ) /Display method Operating range Indication Red Green Red D- Optimum operating position 1297

35 2-Color Indication Type Solid State Auto Switch Tie-rod Mounting Style D-F9W/D-FPW/D-J9W The optimum operating position can be determined by the color of the light. (Red Green Red) D-F9W D-FW, D-J9W (With indicator light) D-F9W D-FPW Wiring type Output type Power supply voltage Current consumption Load current Leakage current -wire NPN PNP IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 80 ma or less 1. V or less (0.8 V or less 0.8 V or less at 10 ma load current) D-J9W 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-FPW (m) 0. D-F9W D-FPW D-J9W Mounting hole D-J9W (+) ( ) /Display method Operating range Indication Red Green Red Optimum operating position 1298

36 2-wire load current is reduced (2. to 40 ma). Flexibility is 1. times greater than the conventional model (SMC comparison). Using flexible cable as standard spec. The optimum operating position can be determined by the color of the light. (Red Green Red) Caution Precautions 2-Color Indication Type Solid State Auto Switch Direct Mounting Style D-M9NW(V)/D-M9PW(V)/D-M9BW(V) Do not fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. D-M9W, D-M9WV (With indicator light) D-M9NW D-M9NWV D-M9PW D-M9PWV D-M9BW D-M9BWV Electrical entry direction Wiring type Output type In-line Perpendicular -wire NPN In-line Perpendicular PNP In-line Perpendicular 2-wire Power supply voltage Current consumption IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 V) 10 ma or less 24 VDC relay, PLC Load current 28 VDC or less 40 ma or less 24 VDC (10 to 28 VDC) 2. to 40 ma Leakage current 0.8 V or less at 10 ma (2 V or less at 40 ma) 100 μa or less at 24 VDC 4 V or less 0.8 ma or less Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof flexible heavy-duty vinyl cord: ø2.7 x.2 ellipse, 0.1 mm 2, 2 cores (D-M9BW(V)), cores (D-M9NW(V), D-M9PW(V)) Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-M9NW, D-M9NWV (m) 0. 1 D-M9NW(V) D-M9PW(V) D-M9BW(V) D-M9PW, D-M9PWV D-M9W 2.6 M2. x 4l Slotted set screw D-M9BW, D-M9BWV (+) D-M9WV 6 M2. x 4l Slotted set screw ( ) 4 / Display method ON D- Operating range OFF Display Red Green Red Optimum operating position

37 The optimum operating position can be determined by the color of the light. (Red Green Red) Using flexible cable as standard spec. D-Y7NW, Y7NWV 2-Color Indication Type Solid State Auto Switch Direct Mounting Style D-Y7NW(V)/D-Y7PW(V)/D-Y7BW(V) D-Y7W, D-Y7WV (With indicator light) D-Y7NW D-Y7NWV D-Y7PW D-Y7PWV D-Y7BW D-Y7BWV Electrical entry direction In-line Perpendicular In-line Perpendicular In-line Perpendicular Wiring type -wire 2-wire Output type NPN IC circuit, Relay, PLC PNP 24 VDC relay, PLC Power supply voltage Current consumption, 12, 24 VDC (4. to 28 VDC) 10 ma or less Load current 28 VDC or less 40 ma or less 1. V or less 80 ma or less 24 VDC (10 to 28 VDC) to 40 ma (0.8 V or less at 10 ma load current) 0.8 V or less 4 V or less Leakage current 100 μa or less at 24 VDC 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof flexible heavy-duty vinyl cord, ø.4, 0.1 mm 2, cores (,, ), 2 cores (, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-Y7PW, Y7PWV (m) D-Y7W 0. D-Y7NW(V) D-Y7PW(V) D-Y7BW(V) M2. x 4l Slotted set screw ø D-Y7BW, Y7BWV 6.2 SMC /Display method D-Y7WV 2. M2. x 4l Slotted set screw Operating range 6.2 SMC Indication Red Green Red 27. ø.4 Optimum operating position 8. (+) ( )

38 D-MNW 2-Color Indication Type Solid State Auto Switch Direct Mounting Style D-MNW/D-MPW/D-MBW The optimum operating position can be determined by the color of the light. (Red Green Red) D-MW (With indicator light) D-MNW D-MPW Wiring type -wire Output type NPN PNP IC circuit, Relay, PLC Power supply voltage Current consumption, 12, 24 VDC (4. to 28 VDC) 10 ma or less Load current 28 VDC or less 40 ma or less 1. V or less 80 ma or less (0.8 V or less 0.8 V or less at 10 ma load current) Leakage current 100 μa or less at 24 VDC D-MBW 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 1 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), 2 cores (, ) 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-MPW (m) 0. D-MNW D-MPW D-MBW D-MBW (+) ( ) ø mounting hole /Display method Operating range Indication Red Green Red D- Optimum operating position 101

39 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Band Mounting Style D-H7NF Since the diagnostic output signal can be detected in an unsteady detecting area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). D-H7NF (With indicator light) D-H7NF Wiring type 4-wire Output type NPN Diagnostic output Normal operation IC circuit, Relay, PLC Power voltage, 12, 24 VDC (4. to 28 VDC) Current consumption 10 ma or less 28 VDC or less Load current 0 ma or less at the total amount of normal output and diagnostic output 1. V or less (0.8 V or less at each output ma) Current leakage 100 μa or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. (Normal output) Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 4 cores (,, Orange, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Diagnosis (Diagnostic output) Orange (m) 0. D-H7NF Diagnostic Output Operation The diagnostic output signal is output within unsteady detecting area (where indicator light is Red), and the diagnostic output becomes OFF when the detecting position remains within the optimum operating position (where indicator is Green). When the detecting position is not adjusted, the diagnostic output becomes ON. (Normal output) Diagnosis (Diagnostic output) OFF ON Red Green Red OFF Red ø.4 ø. mounting hole 102 Most sensitive position

40 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Band Mounting Style D-G9F Since the diagnostic output signal can be detected in an unsteady detecting area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). (Normal output) D-G9F (With indicator light) D-G9F Wiring type 4-wire Output type NPN Diagnostic output Normal operation IC circuit, Relay, PLC Power voltage, 12, 24 VDC (4. to 28 VDC) Current consumption 10 ma or less 28 VDC or less Load current 0 ma or less at the total amount of normal output and diagnostic output 1. V or less (0.8 V or less at ma) Current leakage 100 μa or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0.2 mm 2, 4 cores (,, Orange, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Diagnosis (Diagnostic output) Orange (m) 0. D-G9F Diagnostic Output Operation The diagnostic output signal is output within unsteady detecting area (where indicator light is Red), and the diagnostic output becomes OFF when the detecting position remains within the optimum operating position (where indicator is Green). When the detecting position is not adjusted, the diagnostic output becomes ON. (Normal output) Diagnosis (Diagnostic output) OFF ON Red Green Red OFF Red ø4 ø4. mounting hole D- 10

41 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Rail Mounting Style D-F79F Since the diagnostic output signal can be detected in an unsteady detecting area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). The optimum operating position can be determined by the color of the light. (Red Green Red) (Normal output) Diagnosis (Diagnostic output) Orange D-F79F (With indicator light) D-F79F Wiring type 4-wire Output type NPN Diagnostic output Normal operation IC circuit, Relay, PLC Power supply voltage, 12, 24 VDC (4. to 28 VDC) Current consumption 10 ma or less 28 VDC or less Load current 0 ma or less at the total amount of normal output and diagnostic output 1. V or less (0.8 V or less at ma) Leakage current 100 μa or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord: ø.4, 0.2 mm 2, 4 cores (,, Orange, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. Diagnostic Output Operation The diagnostic output signal is output within an unsteady detecting area (where indicator light is Red), and it is not output within the optimum operating position (where indicator light is Green). When the auto switch detecting position is not adjusted, the diagnostic output becomes activated. Indicator light (Normal output) Diagnosis (Diagnostic output) D-F79F Red Green Red Red ø.2 Mounting hole ø.4 104

42 2-Color Indication Type with Diagnostic Output Solid State Auto Switch: Tie-rod Mounting Style D-F9F Since the diagnostic output signal can be detected in an unsteady detecting area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller). The optimum operating position can be determined by the color of the light. (Red Green Red) D-F9F (With indicator light) D-F9F Wiring type 4-wire Output type NPN Diagnostic output Normal operation IC circuit, Relay, PLC Power supply voltage, 12, 24 VDC (4. to 28 VDC) Current consumption 10 ma or less 28 VDC or less Load current 0 ma or less at the total amount of normal output and diagnostic output 1. V or less (0.8 V or less at ma) Leakage current 100 μa or less at 28 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0.2 mm 2, 4 cores (,, Orange, ), 0. m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (Normal output) Diagnosis (Diagnostic output) Orange (m) 0. Diagnostic Output Operation The diagnostic output signal is output within an unsteady detecting area (where indicator light is Red), and it is not output within the optimum operating position (where indicator light is Green). When the auto switch detecting position is not adjusted, the diagnostic output becomes activated. Indicator light OFF (Normal output) Diagnosis (Diagnostic output) Red D-F9F Green Red OFF Red Mounting hole ø4 D- 10

43 Caution Precautions Water Resistant 2-Color Indication Type Solid State Auto Switch: Band Mounting Style D-H7BAL Water (coolant) resistant type The optimum operating position can be determined by the color of the light. (Red Green Red) Please consult with SMC if using coolant liquid other than water based solution. D-H7BAL (With indicator light) Wiring type Output type Power supply voltage Current consumption Load current Leakage current D-H7BAL 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-H7BA 0 81 (+) ( ) ø.4 /Display method Operating range ø. mounting hole Indication Red Green Red Optimum operating position 106

44 Caution Precautions Water Resistant 2-Color Indication Type Solid State Auto Switch: Band Mounting Style D-GBAL Water (coolant) resistant type The optimum operating position can be determined by the color of the light. (Red Green Red) Please consult with SMC if using coolant liquid other than water based solution. D-GBAL (With indicator light) Wiring type Output type Power supply voltage Current consumption Load current Leakage current D-GBAL 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0.2 mm 2, 2 cores (, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-GBA (+) ( ) ø4 /Display method Operating range ø4. mounting hole Indication Red Green Red Optimum operating position D- 107

45 Water Resistant 2-Color Indication Type Solid State Auto Switch: Rail Mounting Style D-F7BA(V)L Water (coolant) resistant type The optimum operating position can be determined by the color of the light. (Red Green Red) Caution Precautions Please consult with SMC if using coolant liquid other than water based solution. D-F7BA(V)L (With indicator light) D-F7BAL Electrical entry direction Wiring type Output type Power supply voltage Current consumption Load current Leakage current In-line 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC D-F7BAVL Perpendicular Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-F7BA 0 81 D-F7BAV 0 81 (+) D-F7BAL ø.2 mounting hole /Display method D-F7BAVL 8 ø.2 mounting hole 1 ( ) Operating range Indication Red Green Red Optimum operating position 7 SMC 2 ø

46 Caution Water Resistant 2-Color Indication Type Solid State Auto Switch: Tie-rod Mounting Style D-FBAL Water (coolant) resistant type The optimum operating position can be determined by the color of the light. (Red Green Red) Precautions Please consult with SMC if using coolant liquid other than water based solution. D-FBAL (With indicator light) Wiring type Output type Power supply voltage Current consumption Load current Leakage current D-FBAL 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma 4 V or less 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, 2 cores (, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-FBA (+) ( ) Mounting hole /Display method ø4 Operating range Indication Red Green Red Optimum operating position D- 109

47 Water Resistant 2-Color Indication Type Solid State Auto Switch: Direct Mounting Style D-M9NA(V)/D-M9PA(V)/D-M9BA(V) Water (coolant) resistant type 2-wire load current is reduced (2. to 40 ma). The optimum operating position can be determined by the color of the light. (Red Green Red) Using flexible cable as standard spec. Caution Precautions Do not fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. D-M9NA, D-M9NAV D-M9PA, D-M9PAV D-M9A, D-M9AV (With indicator light) Electrical entry direction D-M9NA In-line D-M9NAV Perpendicular D-M9PA In-line D-M9PAV Perpendicular D-M9BA In-line D-M9BAV Perpendicular Wiring type -wire 2-wire Output type NPN PNP Power supply voltage Current consumption IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 V) 10 ma or less 24 VDC relay, PLC Load current 28 VDC or less 40 ma or less 24 VDC (10 to 28 VDC) 2. to 40 ma Leakage current 0.8 V or less at 10 ma (2 V or less at 40 ma) 100 μa or less at 24 VDC 4 V or less 0.8 ma or less (m) Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates D-M9NA(V) Lead wires Oilproof flexible heavy-duty vinyl cord: ø2.7 x.2 ellipse, 0.1 mm 2, 2 cores (D-M9BA(V)), cores (D-M9NA(V), D-M9PA(V)) Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-M9A 4 SMC M2. x 4l Slotted set screw D-M9PA(V) D-M9BA(V) D-M9BA, D-M9BAV 6 (+) D-M9AV ( ) M2. x 4l Slotted set screw /Display method Operating range ON OFF SMC Display Red Green Red Optimum operating position 4 6

48 Caution Water Resistant 2-Color Indication Type Solid State Auto Switch: Direct Mounting Style D-Y7BAL Water (coolant) resistant type Using flexible cable as standard spec. The optimum operating position can be determined by the color of the light. (Red Green Red) Precautions Please consult with SMC if using coolant liquid other than water based solution. Detection characteristics (operating range) are the same as D-Y and D-Y7W, but the detection area length is different. D-Y7BAL (With indicator light) Wiring type Load current Leakage current (m) 0. D-Y7BAL 2-wire 24 VDC Relay, PLC 24 VDC (10 to 28 VDC) to 40 ma or less 4 V or less 0.8 ma or less at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof flexible heavy-duty vinyl cord, ø.4, 0.1 mm 2, 2 cores (, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-Y7BA 4 88 M2. x 4l (+) 2. Slotted set screw 6.2 SMC D-Y7BA ( ) Production lot /Display method 24 VDC Operating range Indication Red Green Red Optimum operating position D- 111

49 For Hygienic Design Cylinders Solid State Auto Switch: Direct Mounting Style D-F6N/D-F6P/D-F6B 2-wire load current is reduced (2. to 40 ma) Using flexible cable as standard spec. D-F6 (With indicator light) Auto switch part no. Electrical entry direction D-F6N D-F6P In-line D-F6B Wiring type -wire 2-wire Output type NPN PNP Power supply voltage Current consumption IC circuit, relay, and PLC, 12, 24 VDC (4. to 28 V) 10 ma or less 24 VDC relay, PLC 28 VDC or less 24 VDC (10 to 28 VDC) Load current 40 ma or less 0.8 V or less 2. to 40 ma 4 V or less Leakage current 100 μa or less at 24 V DC 0.8 ma or less Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord: ø2.7 x.2 ellipse, 0.1 mm 2, 2 cores (D-F6B), cores (D-F6N, D-F6P) Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Caution Precautions Do not fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. (m) 0. D-F6N D-F6P D-F6B D-F6N D-F6 8. (24) 16 D-F6P ø7 2.7 D-F6B (22).2 D-F6B 7 (+) D-F6N/F6P (22).2 ( ) 7 112

50 Solid State Auto Switch with Timer Band Mounting Style D-GNTL With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection D-GNTL (With indicator light) Wiring type Output type Output operation Operating time Off-delay time Power supply voltage Current consumption Load current Leakage current D-GNTL -wire NPN Off-delay 1 ms or less 200 ± 0 ms IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma) 100 μa or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, cores (,, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-GNT Timer Operation Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. scanning. Ex.) Cylinder speed 1000 mm/sec. PLC response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using. Auto switch detecting time Auto switch output ON time PLC response time Auto switch operating range Cylinder speed (mm/s) ø4 ø4. mounting hole D- 11

51 Solid State Auto Switch with Timer Rail Mounting Style D-F7NTL With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection D-F7NTL (With indicator light) Wiring type Output type Output operation Operating time Off-delay time Power supply voltage Current consumption Load current Leakage current D-F7NTL -wire NPN Off-delay 1 ms or less 200 ± 0 ms IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma) 100 μa or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) Timer Operation 0. D-F7NT 7 92 Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. Switch detecting time scanning. Ex.) Cylinder speed 1000 mm/sec. PLC response time 0.1 sec. Switch output ON time Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when PLC response time using. Switch operating range Cylinder speed (mm/s) ø.2 mounting hole ø.4 114

52 Solid State Auto Switch with Timer Tie-rod Mounting Style D-FNTL With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection D-FNTL (With indicator light) Wiring type Output type Output operation Operating time Off-delay time Power supply voltage Current consumption Load current Leakage current D-FNTL -wire NPN Off-delay 1 ms or less 200 ± 0 ms IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) 10 ma or less 28 VDC or less 40 ma or less 1. V or less (0.8 V or less at 10 ma) 100 μa or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, cores (,, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-FNT Timer Operation Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. Switch detecting time scanning. Switch operating range Cylinder speed (mm/s) Ex.) Cylinder speed 1000 mm/sec. PLC response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using. Switch output ON time PLC response time Mounting hole ø4 D- 11

53 Solid State Auto Switch with Timer Direct Mounting Style D-MNTL/D-MPTL With built-in OFF-delay timer (approx. 200 ms) Easy intermediate detection D-MTL (With indicator light) D-MNTL D-MPTL Wiring type -wire Output type NPN PNP Output operation Operating time Off-delay time Power supply voltage Off-delay 1 ms or less 200 ± 0 ms IC circuit, Relay, PLC, 12, 24 VDC (4. to 28 VDC) Current consumption 10 ma or less 28 VDC or less 12 ma or less Load current 80 ma or less 2 V or less (0.8 V or less at 10 ma load current) 0.8 V or less Leakage current 100 μa or less at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), m () Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. D-MNTL D-MPTL (m) Timer Operation 0. D-MNT 60 9 Detection of intermediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e.g. Auto switch scanning. detecting time Ex.) Cylinder speed 1000 mm/sec. PLC response time 0.1 sec. Detecting point dispersion Within 100 mm (= 1000 mm/sec. x 0.1 sec.) Take PLC response time into consideration when using. Auto switch output ON time PLC response time ø.4 D-MPT 60 9 Auto switch operating range Cylinder speed (mm/s) ø mounting hole 116

54 Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch D-P4DWSC/D-P4DWSE (Electrical Entry: Pre-wired connector) It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The optimum operating position can be determined by the color of the light. (Red Green Red) D-P4DWS (With indicator light) D-P4DWSC D-P4DWSE Load current Leakage current Operating time 24 VDC relay, PLC 24 VDC (20 to 28 VDC) 6 to 40 ma or less V or less 1 ma or less at 24 VDC 40 ms or less Lead wires Oilproof heavy-duty vinyl cord, ø6, 0. mm 2, 2 cores, 00 mm Impact resistance Switch: 1000 m/s 2, Connector: 00 m/s 2 Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Caution Precautions For single-phase AC welding machines. Not applicable for DC inverter welding machines (including rectifying type) and or condenser type welding. Magnetic Field Resistance If the current of the AC welding machine is A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm. Please contact SMC when the AC welding current exceeds A. D-P4DWSC D-P4DWSC D-P4DWSE NO. ( ±) NO.4 ( ) ± D-P4DWSE ø6 Connector size M SMC D-P4DW (24 VDC) ø14 NO.1 ( ±) NO.4 ( ) ± x ø. mounting hole 44 1 /Display method 20 6 ON Operating range OFF 1 Most sensitive position Heat shrink tube Note) Indication Red Green Red Note) D-P4DWSC = SC -4, D-P4DWSE = SE 1-4 Optimum operating position D Connector pin 117

55 Magnetic Field Resistant 2-Color Indication Type Solid State Auto Switch D-P4DWL/Z It is possible to use in an environment which generates a magnetic field disturbance (AC magnetic field). The optimum operating position can be determined by the color of the light. (Red Green Red) D-P4DWL/Z (With indicator light) D-P4DWL D-P4DWZ Load current Leakage current Operating time 24 VDC relay, PLC 24 VDC (20 to 28 VDC) 6 to 40 ma or less V or less 1 ma or less at 24 VDC 40 ms or less Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø6, 0. mm 2, 2 cores (, ), D-P4DWL: m, D-P4DWZ: m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Caution Precautions For single-phase AC welding machines. Not applicable for DC inverter welding machines (including rectifying type) and or condenser type welding. (m) 0. D-P4DW D-P4DWL/Z (±) ( ) ± Magnetic Field Resistance If the current of the AC welding machine is A or lower, the auto switch can be used, even if the distance between the welding conductor (gun cable) and the cylinder or switch is 0 mm. Please contact SMC when the AC welding current exceeds A. /Display method ø6 Operating range ON OFF SMC D-P4DW (24 VDC) Indication Red Green Red Optimum operating position 2 x ø. mounting hole 1 118

56 Heat Resistant 2-Color Indication Type Solid State Auto Switch: Rail Mounting Style D-F7NJL Improved heat resistant type The optimum operating position can be determined by the color of the light. (Red Green Red) D-F7NJL (With indicator light) Wiring type Output type Power supply voltage Current consumption Load current Leakage current D-F7NJL -wire NPN Relay, PLC 24 VDC (20 to 26 VDC) 2 ma or less 28 VDC or less 40 ma 0.8 V or less 100 μa at 24 VDC Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Caution Precautions Auto switch which can be mounted on heat resistant, compact cylinder, CDQ2-XB14. For using for other cylinders, please confirm SMC. D-F7NJL is not applicable for the heat resistant type (-XB6) since a magnet is not built in it. Ambient temperature Impact resistance Sensor section: 0 to 10 C Amplifier section: 0 to 60 C Sensor section: 1000 m/s 2 Amplifier section: 00 m/s 2 Lead wires Between sensor and amplifier: Heat resistant heavy-duty cord, ø.4, m on amplifier: Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, cores (,, ), m Sensor section Amplifier section lead wire (m) 0. D-F7NJ of sensor lead wire Max. 10 C /Display method Operating range Indication Red Max. 60 C Green Red ( ) lead wire Optimum operating position HEAT PROOF AUTO SWITCH AMPLIFIRE MODE POSITION (4) (64.) 0.7 D-F7NJ BROWN(+) 24VDC BLACK() NPN 24V40mA BLUE (-) GND BROWN Vcc BLACK Switch Main Circuit MAX. 40mA Load DC24V BLUE GND CAUTION Ambient temp. of detecting circuit (amplifire) is 0~60 C. Don't install heated atmosphere. It might cause mal function and lead to cause breakage. MADE IN JAPAN (000) ø.4 ø.4 Most sensitive position SMC Heat resistant heavy-duty cord 11 D- 119

57 Caution Wide Range Detection Type Solid State Auto Switch: Band Mounting Style D-GNBL Wide range detection type Easy intermediate detection Precautions The operating range is common for all cylinder series, but it may vary depending on bore sizes. D-GNBL (With indicator light) Wiring type Output type Power supply voltage Current consumption Load current Leakage current D-GNBL -wire NPN Relay, PLC 12, 24 VDC (10 to 28 VDC) 12 ma or less 10 to 28 VDC or less 40 ma or less 0.4 V or less 100 μa at 24 VDC Red LED illuminates when turned ON. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, cores (,, ), m Note 1) Refer to page 1272 for solid state auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. (m) 0. D-GNB Applicable Cylinders D-GNBL ( ) Cylinder series CDM2, CDBM2, CDVM, CDVM, CDLM2, CDLG1, MLGC CDG1 CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1 MGC, MGG Operating Range Cylinder series Mountable models D-GNB Bore size 20, 2, 2, 40 20, 2, 2, 40, 0, 6, 80, , 0, 6, 80, , 2, 2, 40, 0 Bore size Note) The operating range above indicates average values at room temperature including hysteresis (assuming approximately ±0% dispersion) SMC ø4 6. ø4. mounting hole 120 (16)

58 Trimmer Auto Switch Series D-7K/D-RK Large work piece 1 and 2 are adjustable separately. 1 Trimmer 2 Trimmer 2 Medium work piece Small work piece Operating range of sensor (LED of sensor is on.) 1 Detecting range Output ON = Green LED is on. Adjustable by trimmer 2 Detecting range Output ON = Orange LED is on. Adjustable by trimmer No work piece Small work piece Medium work piece Large work piece 1 0. mm 0. Minimum width to detect With one switch, various sized work pieces can be detected by the difference of more than 0. mm. on applied actuator. From 0. mm to detectable width dependant One auto switch allows work pieces to be distinguished easily. 2 1 Examples To confirm depth of the machined hole To judge height of a work piece Can be mounted on a standard actuator. Direct mounting / Rail mounting Joining of connector Sensor and amplifier can be connected without restriction. Two mounting types (Amplifier unit) DIN rail mounting / Direct mounting IP67 (Sensor unit) IP40 for amplifier D- 121

59 Trimmer Auto Switch Series D-7K/D-RK Sensor unit Direct mounting type Rail mounting type Specifications Sensor Unit Model Mounting Applicable amplifier unit Electrical entry D-F7K D-Y7K Rail mounting Direct mounting D-RNK, D-RPK Operating position: Red light is ON. Suitable operating position: Green light is ON. Amplifier unit Internal Circuit Sensor Unit D-7K Amplifier Unit D-RNK Sensor 4 White 2 1 D-RPK Sensor 4 White Detective sensor () 1 () 2 (White) () () 1 () 2 (White) () Vsw () GND () S 1 () S 2 (White) Load Load Load Load 12 to 24 VDC 12 to 24 VDC Lead wire Oilproof heavy-duty vinyl cord ø mm 2 With one e-con connector Note) 4 cores m Impact resistance 980 m/s 2 Insulation resistance Withstand voltage Ambient temperature Enclosure 0 MΩ or more (00 VDC Mega) between lead wire and case 1000 VAC for 1 min. (between lead wire and case) 10 to 60 C IP67 8 g (with connector) Note) The e-con connector is not attached to the lead wire. They will be supplied loose in the same shipment. Amplifier Unit (with Sensor Unit) Model D-RNK Applicable sensor unit Application Power supply voltage Current consumption Output specification Load current Leakage current Response time Electrical entry Connection to sensor Power supply/ output cable Lead wire Impact resistance Insulation resistance Withstand voltage Ambient temperature Enclosure D-RPK D-F7K, D-Y7K For relay and PLC 12 to 24 VDC 40 ma or less NPN open collector 2 outputs PNP open collector 2 outputs 28 VDC or less 80 ma or less/1 output 1. V or less 100 μa or less/1 output 1 ms or less READY: Red LED illuminates when the piston position detected. (When the sensor is connected). 1: Green LED illuminates when turned ON. 2: Orange LED illuminates when turned ON. e-con connector Oilproof heavy-duty vinyl cord ø mm 2 4 cores m 98 m/s 2 0 MΩ or more (00 VDC Mega) between lead wire and case 1000 VAC for 1 min. (between lead wire and case) 10 to 60 C IP40 70 g

60 Trimmer Auto Switch Series D-7K/D-RK Descriptions Sensor unit w q q Sensor Unit 1 Red light turns ON when sensor detects the magnet field. Green light is ON during the suitable position to detect the magnetic field (including most sensitive position). 2 ø.2 mounting hole M2. x 4L slotted set screw Fixes the sensor to the actuator. D-F7K Amplifier unit q w e r t e D-Y7K y u Amplifier Unit 1 Output (1) indication: Green Illuminates when 1 outputs. 2 1 adjusting trimmer Adjusts the output range of 1 when sensor unit detects the magnetic field. Output (2) indication: Orange Illuminates when 2 outputs adjusting trimmer Confirmation of detection at sensor unit (READY): Red Offset adjusting trimmer (ADJ) Adjusts the output range of 2 when sensor unit detects the magnetic field. Illuminates when sensor unit is detecting the magnetic field. While its lighting, output ranges of 1 and 2 are adjustable. Adjusts the sensor unit at the time of connection. Once adjusts, no need to re-adjust as long as the sensor unit is not replaced. Adjustment must be undertaken while the sensor unit is removed from the actuator. Refer to the operation manual for details. D-RK 7 Confirmation of offset adjustment (OFFSET): Red Illuminates when offset adjustment is completed. Refer to the operation manual for how to adjust/set. Applicable Actuators and Operation Range (Angle) The operating ranges are provided as guidelines including the hysteresis and are not guaranteed value. Please consult with SMC for alternative actuators other than those shown below. Sensor Unit D-Y7K Air Gripper Model Bore size Parallel gripper MHZ Parallel gripper MHZL Wide opening MHL Parallel gripper MHS2 (2 finger) Parallel gripper MHS ( finger) MHS (L) Parallel gripper MHS4 (4 finger) Angular gripper MHC2 0 to 10 0 to 10 0 to to opening/closing MHW2 88 to 4 to 6 8 to 41 to 0 to 4 Note) The operating range for grippers is measured when both ends are open. Air Cylinder Compact guide cylinder Double power non-rotating cylinder Air cylinder MGP MGZ CA2 Sensor Unit D-F7K Air Cylinder Model Air cylinder Air cylinder Compact cylinder Compact cylinder guide rod type Plate cylinder position cylinder Rotary clamp cylinder CJ2 CM2 CQ2 CQM MU RZQ MK/MK Bore size (mm or ) D-

61 Series D-7K/D-RK Sensor unit D-F7K 8 ø SMC D-F7K D-Y7K Amplifier unit D-RK READY TRIMMER SWITCH SMC ø. SMC M2. x 4L Slotted set screw 6.2 ø. ø D-Y7K 12. DIN rail ( mm width) Supplied by customer D-RNK 6 2 x ø. 124 Connector for sensor e-con 46 Note) The figures above are for D-RNK. For D-RPK, the model name will be printed instead on the body.

62 Trimmer Auto Switch Specific Product Precautions 1 Be sure to read before handling. Refer to front matters 4 and for Safety Instructions and pages 8 to 11 for the Auto Switch Common Precautions. Warning Design and Selection 1. Confirm the specifications. Read the specifications carefully and use this product appropriately. The product may be damaged or malfunction if it is used outside the range of specifications of current load, voltage, temperature or impact. 2. Cautions for use in an interlock circuit. When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the trimmer auto switch. Also perform periodic maintenance and confirm proper operation. Caution 1. Take precautions when multiple cylinders are used close together. When more than 2 trimmer auto switch cylinders are used in close proximity, maintain a minimum actuator interval of 40 mm or more. (When the allowable interval is indicated for each cylinder series, use the specified values.) Magnetic field interference may cause the trimmer auto switches to malfunction. 2. Keep the wiring as short as possible. Use a wire m or shorter between the sensor and amplifier. Although wire length of power supply/output cable should not affect switch function, use a wire 100 m or shorter.. Take precautions for the internal voltage drop of the switch. Auto switches may not operate properly depending on the connected equipment. Caution Mounting and Adjustment 1. Do not drop or bump. Do not drop, bump or apply excessive impacts (980 m/s 2 or more for sensor unit and 98 m/s 2 or more for amplifier unit) while handling. Although the trimmer auto switch body may not be damaged, the inside of the trimmer auto switch could be damaged and cause a malfunction. Caution Wiring 1. Avoid repeatedly bending or stretching lead wires. Broken lead wires will result from applying bending stress or stretching forces to the lead wires. 2. Be sure to connect the connector for sensor to the amplifier before power is applied.. Do not allow short circuit of loads. Output is automatically stopped when the protection circuit is working, as the output unit registers any excess current flow, if loads are short circuited. Should this occur, shut off the power supply, remove the cause of this excess current flow and switch on the power again. Take special care to avoid reverse wiring between the power supply line (brown) and the output line (black, white). 4. Avoid incorrect wiring. If the connections are reversed (power supply line + and power supply line ), the trimmer auto switches will be protected by a protection circuit. However, if the power supply line ( ) is connected to the black, white wire, the trimmer auto switches will be damaged. Warning Operating Environment 1. Never use in an atmosphere with explosive gases. The structure of trimmer auto switches is not designed to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. Caution 1. Do not use in an area where a magnetic field is generated. Trimmer auto switches will malfunction or magnets inside actuators will become demagnetized. 2. Do not use in an environment where the trimmer auto switch will be continually exposed to water. Although the sensor units of trimmer auto switches satisfy the IEC standard IP67 structure, do not use trimmer auto switches in applications where continually exposed to water splash or spray. Poor insulation or swelling of the potting resin inside trimmer auto switches may cause malfunction. (Amplifier part D-RNK and RPK: IP40). Do not use in an environment with oil or chemicals. Please consult with SMC if trimmer auto switches will be used in an environment with coolant, cleaning solvent, various oils or chemicals. If trimmer auto switches are used under these conditions for even a short time, they may be adversely affected by improper insulation, malfunction due to swelling of the potting resin, or hardening of the lead wires. 4. Take measures against freezing when operating at C or less. 12 D-

63 Trimmer Auto Switch Specific Product Precautions 2 Be sure to read before handling. Refer to front matters 4 and for Safety Instructions and pages 8 to 11 for the Auto Switch Common Precautions. Warning Maintenance 1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected trimmer auto switch malfunction. 1) Secure and tighten trimmer auto switch mounting screws. If screws become loose or the mounting position is dislocated, retighten them after readjusting the mounting position. 2) Confirm that there is no damage to lead wires. To prevent faulty insulation, replace trimmer auto switches or repair lead wires, etc., if damage is discovered. Caution Other 1. Please consult with SMC concerning water resistance, elasticity of lead wires, and usage at welding sites, etc. Caution 1. Connection and removal of connector Hold the lever and connector body with two fingers and insert the connector straight into the pin until it is locked with a click sound. To remove the connector, pull it out straight while pressing the lever with one finger. D-Y7K Lever Wiring 2. Connection of sensor connector Cut the sensor lead wire as illustrated to the right. Referring to the table below, insert each lead wire of the cable at the position marked with a number corresponding to the color of the lead wire. Sheath D-RNK 20 mm or more Connector no Insulator Wire core color (S1) (GND) White (S2) (Vsw) Confirm that the numbers on the connector match the colors of the lead wires and that they are inserted to the bottom. Press part A by hand for temporary fixing. Press in the central part of Part A vertically with a tool such as pliers. A sensor connector cannot be taken apart for reuse once it is crimped. If the lead wire arrangement is incorrect or if the wire insertion fails, use a new sensor connector. Part A Use a sensor conector, ZS-28-CA- (1 pc.) or e-con connectors as shown below. Manufacturer Sumitomo M Limited Tyco Electronics AMP K.K. OMRON Corporation Part no FL XN2A-140 For detailed information about e-con connectors, please consult with the manufacturers of the respective connectors. 126

64 Trimmer Auto Switch Specific Product Precautions Be sure to read before handling. Refer to front matters 4 and for Safety Instructions and pages 8 to 11 for the Auto Switch Common Precautions. Caution Use mounting screws (M x 16L) or DIN rail ( mm width). (DIN rail part no.: ISA-2-1 to 7) Adjust offset before mounting of the amplifier unit. 1. Mounting with screws Tighten two M x 16L mounting screws at a tightening torque of 0. to 0.7 N m. Mounting surface should be flat and even. A bumpy or uneven mounting surface can result in damage to the case. Mounting of Amplifier Unit 2. Mounting and removal to DIN rail Mounting Hook the claw 1 of the amplifier body to the upper part of DIN rail, press down and push horizontally until the claw 2 is locked with a click sound. Claw 1 Removal To remove from the DIN rail, push the amplifier body upward and then pull it horizontally to release from the claw 1 side. 1 2 READY TRIMMER SWITCH SMC Claw READY TRIMMER SWITCH SMC Washer M x 16L 1 2 READY TRIMMER SWITCH SMC 1 2 TRIMMER SWITCH SMC In the case of mounting to the DIN rail, SMC recommends the following end plates: as detailed in the table on the right. Consult each manufacturer for the handling and details of end plate. Manufacturer OMRON Corporation IDEC Corporation Part no. PFP-M BNL6. Refer to each applicable actuator s catalog for the mounting of sensor unit. D- 127

65 Made to Order Specifications: Solid State Auto Switch 1 With Pre-wired Connector Eliminates the harnessing work by cable with connector specifications Adopts global standardized connector (IEC947--2) IP67 construction How to Order D M9N S APC Solid state auto switch part no. For the applicable auto switch model, refer to the table below. Cable length S M L 0. m 1.0 m.0 m Note) L is available for the D-P4DW type only. Connector model A B D M8- pin M8-4 pin M12-4 pin Note) Type D is available for the D-P4DW type only. Connector Specifications Connector model M8- pin M8-4 pin M12-4 pin Pin arrangement 4 4 Conformed standard Impact resistance Enclosure Insulation resistance Withstand voltage JIS C 424, JIS C 42, IEC , NECA m/s 2 IP-67 (IEC6029 standard) 100 MΩ or more at 00 VDC Mega 100 VAC 1 minute (between contacts), Leak current 1 ma or less Applicable Auto Switch Mounting Rail mounting style Band mounting style Tie-rod mounting style Function 2-color indication Electrical entry (In-line) (Perpendicular) (In-line) (Perpendicular) With diagnostic output (In-line) Water resistant (Perpendicular) With timer Magnetic field resistant 2-color indication Diagnostic output (In-line) Water resistant With timer Wide detection 2-color indication Diagnostic output Water resistant With timer Applicable model F79, F7P, J79 F7NV, F7PV, F7BV F79W, F7PW, J79W F7NWV, F7BWV F79F F7BA F7BAV F7NT P4DW H7A1, H7A2, H7B G9, GP, K9 H7NW, H7PW, H7BW G9W, GPW, K9W H7NF, G9F H7BA, GBA GNT GNB F9, FP, J9 F9W, FPW, J9W F9F FBA FNT (m) Mounting Function Electrical (m) Applicable model entry (In-line) (Perpendicular) Y9A, Y7P, Y9B Y69A, Y7PV, Y69B (In-line) M9N, M9P, M9B M9NV, M9PV, M9BV (Perpendicular) (In-line) F8N, F8P, F8B F6N, F6P, F6B Direct Normally Y7G, Y7H (In-line) mounting closed F9G, F9H style (In-line) Y7NW, Y7PW, Y7BW 2-color indication Water resistant (Perpendicular) (In-line) (Perpendicular) (In-line) (Perpendicular) Y7NWV, Y7PWV, Y7BWV M9NW, M9PW, M9BW M9NWV, M9PWV, M9BWV Y7BA M9NA, M9PA, M9BA M9NAV, M9PAV, M9BAV S791/2, S7P1/2, T791/2 Rotary (In-line) actuator S991/2, S9P1/2, T991/2 (Perpendicular) S99V1/2, T99V1/2 128

66 With Pre-wired Connector Connector Pin Arrangement Sensor type DC 2-wire type DC 2-wire, Non-polar type DC -wire type DC 4-wire type Color distinction of lead wire 1 pin 2 pin pin 4 pin Orange Meaning of contact number 1 pin 2 pin pin 4 pin (+) Diagnostic output (±) ( ) ( ) ± M8- pin Connector Specifications Connector model M8- pin M8-4 pin M12-4 pin Pin arrangement 4 4 Conformed standard Impact resistance Enclosure Insulation resistance Withstand voltage JIS C 424, JIS C 42, IEC , NECA m/s 2 IP67 (IEC6029 standard) 100 MΩ or more at 00 VDC Mega 100 VAC 1 minute (between contacts), Leak current 1 ma or less M8-4 pin Connector model M8- pin 4 pin Sensor section 1.4 ø10 M12-4 pin M12-4 pin Sensor section ø14 44 for Connector Type Connection (Female side) Connector Cable Part no. D-APC D-BPC D-DPC Connector type M8- M8-4 M g 4 g About 11 g As the parts are not supplied from SMC, refer to the application examples listed in the below. (For detail such as catalog availability, etc., please contact each manufacturer.) Connector size M8 Number of pins Manufacturer Phoenix Contact Corrence Corporation Applicable series example SAC-P M8-D M8-4D OMROM Corporation Phoenix Contact XS SAC-4P D- M12 4 Corrence Corporation OMROM Corporation Yamatake Corporation VA-4D XS2 PA-4I Hirose Electric Co., Ltd. HR24 DKK Ltd. CM01-8DP4S 129

67 Made to Order Specifications: Solid State Auto Switch -0: Without Indicator Light (Dark room) Specifications -61: Oilproof Flexible Cable Specifications 2 Without Indicator Light (for dark room specifications) Possible to use under the environment which hates a light. Symbol -0 D 0 Solid state auto switch model Applicable part no.: General purpose type, solid state auto switch except D-J1 Note) Please consult with SMC for water resistant type, timer equipped type, diagnostic output type, wide range detection type, magnetic field resistant type, heat resistant type. Without indicator light (for dark room specifications) For lead wire length, refer to page and specifications are common as standard products with the exception of no indicator light. Oilproof Flexible Heavy-duty Cord Specifications This is the product which uses a heavy-duty cord having flexible characteristics times (SMC comparison) as strong as oilproof heavy-duty cord used in the standard products. Symbol -61 D 61 Solid state auto switch part no. Applicable part no: All the solid state auto switches with the exceptance of D-J1, diagnostic output type, terminal conduit type, connector type, magnetic field resistant type, heat resistant type Note) Oilproof flexible heavyduty cord is used for D- A A Y9 B, Y69 B, Y7P(V), D-M9, M9V, D- M9W, M9WV, M9AL, M9AVL as standard. No need to suffix -61 to the end of part number. Oilproof flexible heavy-duty cord specifications For lead wire length, refer to page Specifications are the same as standard products with the exception of lead wire specifications. Lead wire: For D-F8 type ø2.7, 0.1 mm 2, cores (,, ), 2 cores (, ) For other model nos. ø.4, 0.1 mm 2, cores (,, ), 2 cores (, ) are identical with D-F type, G type, J9 type, K9 type. Lead wire diameter is changed from ø4 to ø.4. In other series products, it is common as standard product's specifications. 10

68 Reed Auto Switches General Purpose Type, 2-color Indication Type Reed Switch Variations Auto switch Type Function Electrical entry mounting style Page D-C7/C76/C80 D-B/B4/B Connector D-C7C/C80C 14 Band Terminal conduit D-A/A4 D-AA/A4A 1 16 Reed Auto Switch General purpose Rail Tie-rod Direct DIN terminal Connector Terminal conduit DIN terminal D-A44 D-A44A D-A72/A7/A80 D-A72H/A7H/A76H/A80H D-A7C/A80C D-A/A4/A6/A64/A67 D-AC/A4C D-A44C D-A90/A9/A96 D-A90V/A9V/A96V D-Z7/Z76/Z80 D-E7A/E76A/E80A color indication Band Rail Tie-rod D-B9W D-A79W D-A9W Magnetic field resistance Rod D-P79WSE D-P Heat resistant Band Terminal conduit D-B0/1/ D-B0J/1J/J 11 Auto switches with an asterisk ( ) can be mounted on a band (excluding D-A9V), rail, tie-rod or square groove with an auto switch mounting bracket. Refer to pages 16, 160, 164, 168 and 169 for details. This auto switch can be mounted by tie-rod with using auto switch mounting bracket. For details, refer to page 167. D- 11

69 D-C7 Reed switch D-C76 LED Resistor Zener diode Reed Auto Switch Band Mounting Style D-C7/D-C76/D-C80 Contact protection box CD-P11 CD-P12 (+) ( ) D-C7 (With indicator light) Max. load current and range () Contact protection circuit D-C8 (Without indicator light) Max. load current Contact protection circuit Internal resistance (m) 0. D-C7 Relay, PLC 24 VDC 100 VAC to 40 ma to 20 ma None AC 24 V DC or less 0 ma 2.4 V or less Red LED illuminates when turned ON. D-C80 Relay, PLC, IC circuit AC 48 V DC 40 ma D-C76 IC circuit 4 to 8 VDC 20 ma 0.8 V or less 100 V 20 ma None 1 Ω or less (Including lead wire length of m) Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), cores (,, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. D-C7 D-C76 D-C AC DC Reed switch LED Resistor Reverse current prevention diode Load (+) DC ( ) ø.4 D-C SMC Reed switch Contact protection box CD-P11 CD-P12 (±) ( ) ± D-C80 without indicator light ø. Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Note ) is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 127 for contact protection box.) 9. 12

70 D-B ( ) Reed switch Reed Auto Switch Band Mounting Style D-B/D-B4/D-B64 LED Resistor (+) D-B (With indicator light) D-B Load current range () Contact protection circuit D-B6 (Without indicator light) Max. load current Contact protection circuit Internal resistance D-B4 PLC Relay, PLC 24 VDC to 0 ma 24 VDC to 0 ma 100 VAC to 2 ma 200 VAC to 12. ma None Built-in 2.4 V or less 2.4 V or less (to 20 ma)/. V or less (to 0 ma) Red LED illuminates when turned ON. AC 24 V DC or less Max. 0 ma D-B64 Relay, PLC 100 VAC Max. 2 ma Built-in 2 Ω or less 200 VAC Max. 12. ma Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. D-B4 Zener diode (m) 0. D-B D-B4 D-B Zener diode ( ) Choke coil Resistor Reed switch LED (+) Surge absorber 1 ø4 D-B SMC ( ) ± Reed switch Choke coil (±) D-B64 without indicator light Surge absorber ø4. 1. Most sensitive position D- 1

71 D-C7C D-C80C Connector Caution Precautions 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. For details, refer to page 1. Reed switch Resistor LED Zener diode Reed Auto Switch Band Mounting Style D-C7C/D-C80C Contact protection box CD-P12 Choke coil (±) Zener diode ( ) ± (m) 0. D-C7C 14 8 D-C7C (With indicator light) D-C7C Relay, PLC 24 VDC Load current range (4) to 40 ma Contact protection circuit None 2.4 V or less Red LED illuminates when turned ON. D-C80C (Without indicator light) D-C80C Relay, PLC AC 24 V DC or less Maximum load current 0 ma Contact protection circuit None Internal resistance 1 Ω or less (Including lead wire length of m) Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Lead wire with connector may be shipped with switch. Note 4) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. D-C80C 14 8 Reed switch Contact protection box CD-P11 CD-P12 (±) ( ) Lead wire with connector Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 127 for contact protection box.) D-C80C without indicator light 14

72 Reed Auto Switch Band Mounting Style D-A/D-A4/D-A44 Terminal conduit: D-A DIN terminal: D-A4 Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-A ( ) Terminal no. 2 Reed switch LED Resistor (+) Terminal no. 1 D-A (With indicator light) Terminal conduit Load current range (2) Contact protection circuit D-A PLC 24 VDC to 0 ma None 24 VDC to 0 ma D-A4 Relay, PLC 100 VAC to 2 ma Built-in 200 VAC to 12. ma 2.4 V or less 2.4 V or less (to 20 ma)/. V or less (to 0 ma) Red LED illuminates when turned ON. D-A44 (With indicator light) DIN terminal Load current range Contact protection circuit 24 VDC to 0 ma D-A44 Relay, PLC 100 VAC to 2 ma Built-in 200 VAC to 12. ma 2.4 V or less (to 20 ma)/. V or less (to 0 ma) Red LED illuminates when turned ON. Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. Zener diode Lead wire None D-A D-A4 D-A D-A4, D-A44 ( ) Terminal no. 2 Choke coil Reed switch LED Resistor Zener diode Surge absorber (+) Terminal no. 1 D-A Tightening gland D-A44 Tightening gland G 1/2 G 1/2 Applicable cable O.D. ø6.8 to ø9.6 Applicable cable O.D. ø6.8 to ø11. D- 1

73 Terminal conduit: D-AA DIN terminal: D-A44A Caution Precautions 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-AA ( ) Terminal no. 2 Reed switch Reed Auto Switch Band Mounting Style D-AA/D-A4A/D-A44A LED Resistor Zener diode (+) Terminal no. 1 D-AA (With indicator light) Terminal conduit Load current range (2) Contact protection circuit D-AA PLC 24 VDC to 0 ma None 24 VDC to 0 ma D-A4A Relay, PLC 100 VAC to 2 ma Built-in 200 VAC to 12. ma 2.4 V or less 2.4 V or less (to 20 ma)/. V or less (to 0 ma) Red LED illuminates when turned ON. D-A44A (With indicator light) DIN terminal Auto switch part model Load current range Contact protection circuit 24 VDC to 0 ma D-A44A Relay, PLC 100 VAC to 2 ma Built-in 200 VAC to 12. ma 2.4 V or less (to 20 ma)/. V or less (to 0 ma) Red LED illuminates when turned ON. Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. D-A4A, D-A44A ( ) Terminal no. 2 Choke coil Reed switch LED Resistor Zener diode Surge absorber (+) Terminal no. 1 D-AA D-A4A D-A44A Lead wire None D-AA D-A44 G 1/2 (Applicable cable O.D. ø6.8 to ø9.6) Tightening gland Tightening gland G 1/2 (Applicable cable O.D. ø6.8 to ø11.) 16

74 Reed Auto Switch Rail Mounting Style D-A72/D-A7/D-A80 Electrical entry: Perpendicular D-A72 Reed switch Resistor LED Zener diode Contact protection box CD-P11 Choke coil Surge absorber ~ D-A7 (With indicator light) D-A72 Relay, PLC D-A7 Relay, PLC Load current range () Contact protection circuit 200 VAC to 10 ma 24 VDC to 40 ma None 2.4 V or less 100 VAC to 20 ma Red LED illuminates when turned ON. D-A8 (Without indicator light) D-A80 Relay, IC circuit, PLC AC 24 V DC or less 48 V DC AC 100 V DC AC Maximum load current Contact protection circuit 0 ma 40 ma None 20 ma Internal resistance 1 Ω or less (Including lead wire length of m) Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. D-A7 Reed switch LED Resistor Zener diode Contact protection box CD-P11 CD-P12 (+) ~ ( ) (m) 0. D-A72 D-A7 D-A D-A80 Reed switch Contact protection box CD-P11 CD-P12 (±) ~ ( ) ± 11. (11.7) 1 (14) 7 (6) 4 ø.4 8 ø.2 2 (22) D-A80 without indicator light Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Note ) is 100 VAC or 200 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. Especially in the case of D-A72, be sure to use the contact protection box. (Refer to page 127 for contact protection box.) 6 (6.2) 9 (8.) ( ) values for D-A72 D- 17

75 D-A72H Reed switch D-A7H Reed switch D-A76H D-A80H Reed Auto Switch Rail Mounting Style D-A7H/D-A80H Electrical entry: In-line Reed switch Resistor LED Zener diode Resistor LED Zener diode LED Resistor Reverse current prevention diode Contact protection box CD-P11 Load Choke coil Surge absorber Contact protection box CD-P11 CD-P12 (+) ~ (+) ~ ( ) DC power supply ( ) (m) D-A7H, D-A80H 0. D-A72H D-A7H D-A76H D-A80H ø D-A7H (With indicator light) D-A72H D-A7H D-A76H Relay, PLC Relay, PLC IC circuit 200 VAC 24 VDC 100 VAC 4 to 8 VDC Max. load current/load current range () to 10 ma to 40 ma to 20 ma 20 ma Contact protection circuit None 2.4 V or less 0.8 V or less Red LED illuminates when turned ON. D-A80H (Without indicator light) D-A80H Relay, IC circuit, PLC AC 24 V DC or less 48 V DC AC 100 V DC AC Maximum load current 0 ma 40 ma 20 ma Contact protection circuit None Internal resistance 1 Ω or less (Including lead wire length of m) Lead wires Oilproof heavy-duty vinyl cord, 0.2 mm 2, 2 cores (, ), cores (,, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more Reed switch Contact protection box CD-P11 CD-P12 (±) ~ ( ) ± D-A80H without indicator light SMC Note 1) Operating load is an induction load. Note 2) Wiring to the load is more than m. Note ) is 100 VAC or 200 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. Especially in the case of D-A72H, be sure to use the contact protection box. (Refer to page 127 for contact protection box.) ø.4 18

76 Caution Precautions D-A7C D-A80C Reed Auto Switch Rail Mounting Style D-A7C/D-A80C Connector 1. Confirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. 2. Refer to page 1 for the details. Reed switch Resistor LED Zener diode Contact protection box CD-P12 Choke coil (+) Zener diode ( ) D-A7C (With indicator light) D-A7C Relay, PLC 24 VDC Load current range (4) to 40 ma Contact protection circuit None 2.4 V or less Red LED illuminates when turned ON. D-A80C (Without indicator light) D-A80C Relay, IC circuit, PLC 24 V DC AC Maximum load current 0 ma Contact protection circuit None Internal resistance 1 Ω or less (Including lead wire length of m) Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Lead wire with connector may be shipped with the auto switch. Note 4) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. (m) 0. D-A7C D-A80C Reed switch Contact protection box CD-P11 CD-P12 (±) ~ ( ) ± Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 127 for contact protection box.) Lead wire with connector D-A80C without indicator light D- 19

77 D-A ( ) D-A4 ( ) D-A6 Reed switch Reed switch Reed switch Reed Auto Switch Tie-rod Mounting Style D-A/D-A6 LED Zener diode Resistor Surge absorber Zener diode LED Resistor LED Resistor Load Reverse current prevention diode Choke coil (+) (+) (+) DC power supply ( ) D-A (With indicator light) D-A Maximum load () current and range Contact protection circuit (m) PLC 24 VDC to 0 ma None 2.4 V or less D-A6 (Without indicator light) 0. D-A D-A4 D-A6 D-A64 D-A VDC to 0 ma D-A4 Relay, PLC 100 VAC to 2 ma Built-in 2.4 V or less (to 20 ma)/. V or less (to 0 ma) VAC to 12. ma Red LED illuminates when turned ON D-A6 IC circuit 4 to 8 VDC 20 ma None 0.8 V or less Maximum load current Contact protection circuit Internal resistance AC 24 V DC or less 0 ma D-A64 Relay, PLC 100 VAC 2 ma Built-in 2 Ω or less 200 VAC 12. ma D-A67 PLC/IC circuit Max. 24 VDC 0 ma None 1 Ω or less (Including lead wire length of m) Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, 2 cores (, ), or 0.2 mm 2, cores (,, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. D-A64 22 Choke coil 12 ( ) ± Reed switch (±) D-A64/A67 without indicator light 12 Surge absorber ø4 D-A ( ) ± Reed switch (±)

78 Caution Precautions Reed Auto Switch Tie-rod Mounting Style D-AC/D-A4C/D-A44C Terminal conduit:d-ac DIN terminal: D-A44C 1. Use cable whose O.D. is within the size in the figure to maintain water resistant performance. 2. After wiring, confirm that tightening gland and all screws are tightened. D-AC ( ) Terminal no. 2 D-A4C, D-A44C D-AC Reed switch LED Resistor Zener diode Choke coil Reed switch LED ( ) Resistor Terminal no. 2 Zener diode Surge absorber (+) Terminal no. 1 (+) Terminal no. 1 2 x M x 0.8 x 12 Hexagon socket head cap bolt Tightening gland D-AC (With indicator light) Terminal conduit Load current range (2) Contact protection circuit D-AC PLC 24 VDC to 0 ma None 24 VDC to 0 ma D-A4C Relay, PLC 100 VAC to 2 ma Built-in 200 VAC to 12. ma 2.4 V or less 2.4 V or less (to 20 ma)/. V or less (to 0 ma) Red LED illuminates when turned ON. D-A44C (With indicator light) DIN terminal Load current range (2) Contact protection circuit 24 VDC to 0 ma D-A44C Relay, PLC 100 VAC to 2 ma Built-in 200 VAC to 12. ma 2.4 V or less (to 20 ma)/. V or less (to 0 ma) Red LED illuminates when turned ON. D-AC D-A4C D-A44C Applicable bore size Applicable bore size D-AC-4, D-A44C-4 40 D-AC-, D-A44C- 0 D-AC-6, D-A44C-6 6 D-AC-8, D-A44C-8 80 D-AC-10, D-A44C ( ): Denotes the values of D-A44C D-A44C C HW H 8 (67.) 9 (68.) 61. (71) 6 (74.) 68 (77.) Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. H' 0. (60) 1. (61) (62.) 4. (64) 7. (67) T x M x 0.8 x 12 Hexagon socket head cap bolt Tightening gland T' Z M x 0.8 x 16 M x 0.8 x 20 M x 0.8 x 2 4 x Z Hexagon socket head cap bolt G 1/2 4 x Z G 1/2 (Applicable cable O.D. Hexagon socket (Applicable cable O.D. ø6.8 to ø9.6) head cap bolt ø6.8 to ø11.) D- 141

79 Reed Auto Switch Direct Mounting Style D-A90(V)/D-A9(V)/D-A96(V) Caution Precautions Do not fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. D-A90, A90V D-A9, A9V Reed switch Reed switch LED Resistor Zener diode (Red) () Contact protection box CD-P11 CD-P12 Contact protection box CD-P11 CD-P12 (±) ( ) ± (+) ( ) D-A90, D-A90V (Without indicator light) D-A90, D-A90V Maximum load current Contact protection circuit Internal resistance D-A9, D-A9V, D-A96, D-A96V (With indicator light) D-A9, D-A9V Load current range and Maximum load current () Contact protection circuit to 40 ma to 20 ma None 20 ma D-A9: 2.4 V or less (up to 20 ma)/ V or less (up to 40 ma) D-A9V: 2.7 V or less Red LED illuminates when turned ON. 0.8 V or less Lead wires D-A90(V)/D-A9(V)Oilproof heavy-duty vinyl cord, ø2.7, 0.18 mm 2 x 2 cores (, ), 0. m D-A96(V)Oilproof heavy-duty vinyl cord, ø2.7, 0.1 mm 2 x cores (,, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. Model (m) 0. D-A90/D-A9/D-A IC circuit, Relay, PLC AC AC AC 24 V DC or less 48 V DC or less 100 V DC or less 0 ma 40 ma 20 ma None 1 Ω or less (Including lead wire length of m) D-A VDC 4. Relay, PLC D-A90V D-A VAC D-A9V 6 0 ø2.7 D-A96, D-A96V IC circuit 4 to 8 VDC D-A D-A96V 8 41 D-A96, A96V Reed switch LED Resistor Reverse current prevention diode Load (+) 4 M2. x 4L Slotted set screw D-A90V/D-A9V/D-A96V 22 (24.) D-A90 without indicator light Most sensitive 10 position ( ): dimensions for D-A9. Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Note ) is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 127 for contact protection box.) M2. x 4L Slotted set screw ø DC power supply ( ) 4. D-A90V without indicator light

80 D-Z7 Reed switch D-Z76 Reed switch D-Z80 Reed switch Resistor LED Zener diode LED Resistor Reverse current prevention diode Reed Auto Switch Direct Mounting Style D-Z7/D-Z76/D-Z80 Load Contact protection box CD-P11 CD-P12 Contact protection box CD-P11 CD-P12 (+) ( ) (±) ( ) (+) ( ) DC power supply ± D-Z7 (With indicator light) D-Z7 Relay, PLC D-Z76 IC circuit Max. load current and load current range () Contact protection circuit 24 VDC to 40 ma 100 VAC to 20 ma None 4 to 8 VDC 20 ma 2.4 V or less (to 20 ma)/ V or less (to 40 ma) 0.8 V or less Red LED illuminates when turned ON. D-Z8 (Without indicator light) D-Z80 Relay, PLC, IC circuit AC 24 V DC or less 48 V AC 100 V AC DC DC Maximum load current Contact protection circuit Internal resistance 0 ma 40 ma None 1 Ω or less (Including m lead wire) 20 ma D-Z7 (m) M2. x 4L Slotted set screw D-Z7 D-Z76 D-Z D-Z76,Z80 M2. x 4L Slotted set screw 6.2 Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), cores (,, ), 0. m (For only D-Z7, ø2.7, 0.18 mm 2, 2 cores) Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more D-Z80 without indicator light Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Note ) is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 127 for contact protection box.). 12. Most sensitive position ø Most sensitive position D- 14

81 Reed Auto Switch Direct Mounting Style D-E7A/D-E76A/D-E80A D-E7A Reed switch D-E76A Reed switch LED Resistor Zener diode LED Resistor Reverse current prevention diode Load Contact protection box CD-P11 CD-P12 (+) (+) ( ) DC power supply ( ) D-E7A (With indicator light) D-E7A Relay, PLC D-E76A IC circuit Max. load current and load current range () Contact protection circuit 24 VDC to 40 ma 100 VAC to 20 ma None 4 to 8 VDC 20 ma 2.4 V or less 0.8 V or less Red LED illuminates when turned ON. D-E80A (Without indicator light) D-E80A Relay, PLC, IC circuit AC 24 V DC or less 48 V AC 100 V AC DC DC Maximum load current Contact protection circuit 0 ma 40 ma None 20 ma Internal resistance 1 Ω or less (Including lead wire length of m) Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), cores (,, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. (m) 0. D-E7A D-E76A D-E80A D-E80A 8 8 Reed switch Contact protection box CD-P11 CD-P12 (±) ( ) ± D-E80A without indicator light 22 Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Note ) is 100 VAC. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 127 for contact protection box.) ø.4 SMC 8. D-E7A

82 2-Color Indication Type Reed Auto Switch Band Mounting Style D-B9W The optimum operating position can be determined by the color of the light. (Red Green Red) D-B9W (With indicator light) Load current range () Contact protection circuit D-B9W Relay, PLC 24 VDC to 40 ma Built-in 4 V or less Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. D-B9W Choke coil (+) Reed switch Zener diode LED ( ) (m) 0. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. D-B9W /Display method Operating range Indication Red Green Red 1 ø4 Optimum operating position ø D- 14

83 2-Color Indication Type Reed Auto Switch Rail Mounting Style D-A79W The optimum operating position can be determined by the color of the light. (Red Green Red) D-A79W (With indicator light) Load current range () Contact protection circuit D-A79W Relay, PLC 24 VDC to 40 ma None 4 V or less Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. D-A79W Lead wires Oilproof heavy-duty vinyl cord, ø.4, 0.2 mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. (+) Reed switch Reverse flow prevent diode LED ( ) /Display method (m) 0. D-A79W 11 Operating range 8 ø.2 Indication Red Green Red Optimum operating position 2. Note 1) Operating load is an induction load. Note 2) Wiring to the load is m or longer. Use the contact protection box in any of the above listed situations. The contact point life may decrease. (Refer to page 127 for contact protection box.) ø

84 2-Color Indication Type Reed Auto Switch Tie-rod Mounting Style D-A9W The optimum operating position can be determined by the color of the light. (Red Green Red) D-A9W Choke coil (+) Reed switch Zener diode LED ( ) /Display method D-A9W (With indicator light) D-A9W Relay, PLC 24 VDC Load current range () to 40 ma Contact protection circuit Built-in 4 V or less Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof heavy-duty vinyl cord, ø4, 0. mm 2, 2 cores (, ), 0. m Note 1) Refer to page 1272 for reed auto switch common specifications. Note 2) Refer to page 1272 for lead wire lengths. Note ) Under ma, the strength of the indicator light is poor. In some cases, visibility of the indicator light will not be possible where the output signal is less than 2. ma. However, there is no problem in terms of contact output, when an output signal exceeds 1 ma or more. (m) 0. D-A9W 2 80 Operating range ø4. Indication Green Red Optimum operating position ø D- 147

85 Magnetic Field Resistant 2-Color Indication Type Reed Auto Switch D-P79WSE (Electrical Entry: Pre-wired connector) The optimum operating position can be determined by the color of the light. (Red Green Red) Load current range Contact protection circuit D-P79WSE PLC 24 VDC 8 to 20 ma Yes 6 V or less Operating position... Red LED illuminates. Optimum operating position... Green LED illuminates. Lead wires Oilproof, fire resistant heavy-duty vinyl cord, ø6, 0.7 mm 2, 2 cores, 00 mm Note 1) Refer to page 1272 for reed auto switch common specifications. Caution Precautions Cylinder with a strong integrated magnet must be used. D-P79WSE 100 D-P79WSE Lead switch Choke coil NO.1 (+) D-P79WSE Light circuit LED Zener diode NO.4 ( ) 14.6 D-P79W DC24V MADE IN JAPAN SMC Heat shrink tube Note) Connector size M12 ø14 /Display method Operating range ON Indication Red Green Red 4 ø6 20 OFF Soft resin mold surface (Mounting surface for the switch mounting bracket side) 2 x 2 x ø6 Counterbore depth x ø.4 through Optimum operating position Connector pin 16 Note) D-P79WSE = SE 1 4- Caution Please be careful of the mounting direction. The soft resin mold surface must be directed to the switch mounting bracket side. 148

CDA2-X1184 MDB-X1184 MDB1 CDA2 CDUJ CDU CDS1 CDS2. ø12 to ø20. ø125 to ø160. ø6 to ø32. ø6 to ø10 P.1516

CDA2-X1184 MDB-X1184 MDB1 CDA2 CDUJ CDU CDS1 CDS2. ø12 to ø20. ø125 to ø160. ø6 to ø32. ø6 to ø10 P.1516 Best 2 Pneumatics Auto Switch Guide Applicable Cylinder Series 1 Cylinder series CDJP2 CDJ2 CDM2 CDG1 MDB MDB-X1184 MDB1 CDA2 CDA2-X1184 CDS1 CDS2 CDUJ CDU CDQS CDQ2 CDQ2-XB14 RDQ CDQM MDU CDJ S CDG S

More information

SMC Auto Switch Variations

SMC Auto Switch Variations SMC Auto Variations Mounting Function Style method Electrical entry Auto switch model No. Page D-C7/C7/C80 D-B5/B54/B4 5.-9 5.- Connector D-C7C/C80C 5.- Terminal conduit D-A/A4 D-AA/A4A 5.- 5.- DIN terminal

More information

Applicable Cylinder Series

Applicable Cylinder Series Auto Switch Guide Applicable Cylinder Series Applicable Cylinder Series 1 A Solid state auto switches Reed auto switches Cylinder series Bore size D-H7 D-H7C D-H7BA D-H7NF D-H7W D-G5/K5 D-G5BA D-G59F D-G5NT

More information

Applicable Auto Switch Model

Applicable Auto Switch Model Applicable Auto Switch Model Refer to p..-2 to.- for the detailed specifications of auto switches. Applicable Auto Switch Model Reed Switch Solid State Switch Cylinder D-C/C D-CC/C0C D-B/B D-BW D-A/A D-A

More information

Applicable Auto Switch Variations

Applicable Auto Switch Variations Rotary Actuators, Air Grippers Applicable Auto Switch Variations Rotary Actuators Applicable Auto Switch Variations Type Auto switch mounting type Electrical entry Applicable series Size CDRA1 30 to 100

More information

Guide Table. ø40, ø63, ø100

Guide Table. ø40, ø63, ø100 Guide Table Series MGF ø, ø, ø Low-profile compact cylinder utilizes a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting height greatly reduced Low-profile cylinder

More information

Guide Table. Series MGF

Guide Table. Series MGF Guide Table Series MGF ø, ø, ø0 Low-profile compact cylinder utilizes a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting height greatly reduced Low-profile cylinder

More information

Guide Table. MGF Series

Guide Table. MGF Series Guide Table MGF Series ø, ø, ø0 Low-profile compact cylinder utilizes a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting height greatly reduced Low-profile cylinder

More information

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes 2,, Finger Air Gripper Auto Switch Common Specifications Auto Switch Common Specifications Operating time Impact resistance Insulation resistance Withstand voltage Ambient temperature Enclosure Solid state

More information

Reed Switches/Direct Mounting Type D-Z73/Z76/Z80

Reed Switches/Direct Mounting Type D-Z73/Z76/Z80 Reed es/direct Mounting Type D-Z73/Z76/Z80 uto Internal Circuits Lead wire colors inside [ ] are old colors prior to conformity with IEC standards. D-Z73 Reed LED Resistor Zener diode Contact box (+) ()

More information

Tecnopoint srl Tel Fax

Tecnopoint srl Tel Fax Auto Guide 175 Auto Guide Select an auto switch model according to the series and the mounting style. Size Direct Direct Direct (Round Groove) (Rectangular Groove) (for rotary actuators) Auto Mounting

More information

New cylinder body allows small auto switches to be mounted on 4 surfaces.

New cylinder body allows small auto switches to be mounted on 4 surfaces. Toggle Type Air Gripper ø32, ø4, ø5, ø63 New cylinder body allows small auto switches to be mounted on 4 surfaces. RoH Auto switch mounting rail removed. A round slot for mounting small auto switches is

More information

Dual-Rod Cylinder Compact Type

Dual-Rod Cylinder Compact Type CAT.ES-7 B Dual-Rod Cylinder Compact Type New Made to Order additionally released. (For details, refer to page 22.) Auto switch can be installed from 3 directions. Reverse Series CXSJ /ø, ø0, ø, ø, ø2,

More information

Series RSH/RS1H. To stop pallets gently. Stopper cylinder with built-in shock absorber. Heavy Duty Stopper Cylinder. ø20, ø32 ø50, ø63, ø80

Series RSH/RS1H. To stop pallets gently. Stopper cylinder with built-in shock absorber. Heavy Duty Stopper Cylinder. ø20, ø32 ø50, ø63, ø80 CAT.ES-118 B Heavy Duty Stopper Cylinder Series RSH/RS1H ø, ø ø, ø, ø To stop pallets gently Stopper cylinder with built-in shock absorber Heavy Duty Stopper Cylinder Series RSH/RS1H ø, ø ø, ø, ø To stop

More information

SeriesMHZL2 How to Order

SeriesMHZL2 How to Order Parallel Type ir Gripper Long Stroke SeriesMHZL2 How to Order 1 2 2 ore size Number of fingers 2 2 fingers 1mm mm 2mm 2mm MHZL2 D S C ction Double acting Single acting (normally open) Single acting (normally

More information

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g. Compact Slide Series ø, ø, ø, ø RoHS Allowable moment MXS Improved by up to MXQ MXQ 2% MXF MXW MXJ MXP MXY With new high rigidity linear guide MTS Allowable moment improvement illustrated below Allowable

More information

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,

More information

Compact Guide Cylinder Series MGQ

Compact Guide Cylinder Series MGQ Compact Guide Cylinder Series ø, ø, ø, ø, ø, ø, ø, ø, ø, ø0 ir cylinder with guide integrated that has achieved anti-lateral load and high non-rotating accuracy. Space-saving cylinder. Suitable as stoppers

More information

2 4times. Compact Cylinder/Guide Rod Type. Guide rod. Load can be directly mounted. Mounting dimensions compatible with the CQS, CQ2 series.

2 4times. Compact Cylinder/Guide Rod Type. Guide rod. Load can be directly mounted. Mounting dimensions compatible with the CQS, CQ2 series. CAT.ES-1 B Compact Cylinder/Guide Rod Type Lateral load resisting 24times Compared to compact cylinder series CQ Non-rotating accuracy ±0.2 or less Refer to page 3 for details. Guide rod ø3,ø,ø0 has been

More information

Dual-Rod Cylinder Compact Type

Dual-Rod Cylinder Compact Type CAT.EUS20-7 B -UK Dual-Rod Cylinder Compact Type New Made to Order additionally released. (For details, refer to page 22.) Auto switch can be installed from 3 directions. Reverse Series CXSJ/ø, ø0, ø,,

More information

Toggle Type Air Gripper

Toggle Type Air Gripper ø2, ø40, ø50, ø6 Ideal for gripping heavy workpiece Toggle mechanism is adopted. Holds workpiece even when pressure drops. The toggle mechanism that activates when the finger closes realizes strong and

More information

Series MGF ø40, ø63, ø100

Series MGF ø40, ø63, ø100 Guide Table Series MGF ø, ø, ø How to Order MGF Z7 Guide table Number of auto switches 2 S 1 Cylinder bore size/ Standard stroke,, 7,,, 7,,, 7, Auto switch Without auto switch * Refer to the table below

More information

Series MHZ2/MHZJ2. Parallel Type Air Gripper. Series MHZJ2 with dust cover introduced! New finger options added to Series MHZ2 standard type.

Series MHZ2/MHZJ2. Parallel Type Air Gripper. Series MHZJ2 with dust cover introduced! New finger options added to Series MHZ2 standard type. CAT.E273- B Parallel Type Air Gripper Standard Type With Dust Cover Series MHZ2/MHZJ2 Series MHZJ2 with dust cover introduced! New finger options added to Series MHZ2 standard type. Integrated linear guide

More information

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Compact Slide. Series MXH ø6, ø10, ø16, ø20 Compact Slide Series ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Endless track linear guide Series Variations

More information

Compact Guide Cylinder

Compact Guide Cylinder Compact Guide Cylinder Series ø, ø, ø, ø, ø, ø, ø, ø, ø, ø ir cylinder with guide integrated that has achieved anti-lateral load and high non-rotating accuracy. Space-saving cylinder. Suitable as stoppers

More information

Auto Switch Guide. Consolidate your auto switches. Simplify your onsite inventory control. Band mounting Rail mounting.

Auto Switch Guide. Consolidate your auto switches. Simplify your onsite inventory control. Band mounting Rail mounting. mounting mounting Auto Guide Groove mounting Tie-rod mounting Consolidate your auto switches. Simplify your onsite inventory control. Contents - Auto Guide Section Auto Guide Select an auto switch model

More information

Valve Mounted Cylinder Double Acting, Single Rod. How to Order. Electrical entry. L L plug connector M M plug connector. G Grommet

Valve Mounted Cylinder Double Acting, Single Rod. How to Order. Electrical entry. L L plug connector M M plug connector. G Grommet L F Mounting style asic style xial foot style Rod side flange style With auto switch CVJ L CDVJ L 6 6 How to Order pplicable uto Switches/Refer to pages to for further information on auto switches. Type

More information

Mini Free Mount Cylinder

Mini Free Mount Cylinder Mini Free Mount Cylinder ø, ø, ø, ø, ø, ø1, ø Series CUJ Added ø, ø1, ø bore sizes. Action Double acting Single acting, spring return Double acting Single acting, spring return Double acting Single acting,

More information

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series High-Precision Digital Pressure Switch ZSE40 /ISE40 Series Set pressure range 0.00 to.000 Pa For positive pressure How to Order For Positive Pressure ISE40 0 22 SDPC For Vacuum/Compound Pressure ZSE40

More information

Series MXU ø6, ø10, ø16

Series MXU ø6, ø10, ø16 Compact Slide Series ø, ø, ø1 Displacement accuracy against moments Table edge displacement M1(Pitch moment): 0.02mm or less M2(Yaw moment): 0.01mm or less The miniature linear guide improves the linear

More information

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New: CAT.ES-3 E -UK Dual-Rod Cylinder Series CXS New: CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ Dual-Rod Cylinder with guide functio for pick-and-place applications Series CXS! Twice the

More information

Traveling parallelism: mm. Mounting from the through-holes on the top Tapped for mounting a work piece

Traveling parallelism: mm. Mounting from the through-holes on the top Tapped for mounting a work piece CAT.ES-1 A Air Slide Table Series MXJ Height: mm/width: mm/length: mm (MXJ) Note 1) Front mounting accuracy: 0.01 mm Note ) Top mounting accuracy: 0.0 mm Traveling parallelism: 0.00 mm Integrated front

More information

Microspeed Cylinders

Microspeed Cylinders EP97-2-C-UK Microspeed Cylinders CJ2X/CUX/CQSX/CQ2X/CM2X (ø, ø) (ø to ø32) (ø12 to ø25) (ø32 to ø0) (ø to ø) Clean room compatible Series -/11- Achieves stable low speed operation even at 0.5mm/s (1mm/s

More information

Elliptical design for space-savings

Elliptical design for space-savings Plate Cylinder Series,,,, By adopting an elliptical piston design, a slim, square shaped body has been achieved, resulting in a space-saving cylinder with unrestricted mounting directions. Elliptical design

More information

2 4times. Compact Cylinder/Guide Rod Type. ±0.2 or less. Guide Rod. Load can be directly mounted.

2 4times. Compact Cylinder/Guide Rod Type. ±0.2 or less. Guide Rod. Load can be directly mounted. CAT.ES-19 A -UK Compact Cylinder/Guide Rod Type Lateral Load Resisting 24times Compared to compact cylinder series CQ Non-rotating accuracy ±0.2 or less Refer to page 3 for details. Guide Rod Load can

More information

Series MXH/ ø6, ø10, ø16, ø20

Series MXH/ ø6, ø10, ø16, ø20 Compact Slide Series / ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. CL MLG CNA CNG MNB CNS CLS CB CV/MVG

More information

Heavy Duty Stopper Cylinder

Heavy Duty Stopper Cylinder Heavy Duty Stopper Cylinder Series ø, ø32 To stop pallets gently Stopper cylinder with built-in shock absorber Amount of energy absorption can be adjusted to suit the load. Stops the workpiece gently with

More information

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

CAT.ES20-53 E -UK. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New: CAT.ES-3 E -UK Dual-Rod Cylinder Series New: Dual-Rod Cylinder with Air Cushion Compact Type Series J Dual-Rod Cylinder with guide function for pick-and-place applications Series! Twice the thrust Non-rotating

More information

Dual Rod Cylinder. ø6, ø10, ø15, ø20, ø25, ø32. Dual rod cylinder with guide function suitable for pick & place applications.

Dual Rod Cylinder. ø6, ø10, ø15, ø20, ø25, ø32. Dual rod cylinder with guide function suitable for pick & place applications. Dual Rod Cylinder Series J/ ø, ø0, ø, ø, ø, Dual rod cylinder with guide function suitable for pick & place applications. Twice the thrust Non-rotating accuracy ±0. Ball bushing bearings and slide bearings

More information

ISO Cylinders. Series CP96/C96 CAT.EUS20-204A-UK. Series CP96. Series C96. ø32, ø40, ø50, ø63, ø80, ø100, ø125

ISO Cylinders. Series CP96/C96 CAT.EUS20-204A-UK. Series CP96. Series C96. ø32, ø40, ø50, ø63, ø80, ø100, ø125 ISO Cylinders ø, ø, ø, ø, ø, ø0, ø Conforming to ISO 2. CNOMO and circular grooves are set on all four sides. Switch can slide in. Profile Design ISO Cylinder Series CP6 Variations Series C6 Series Action

More information

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping.

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping. Dual Rod Cylinder / Series ø,,,,, Dual rod cylinder with guide function suitable for pick & place applications. Ball bushing bearings and slide bearings are standard for all series. Dimensions for ball

More information

Compact Cylinder: Large Bore Size Type Double Acting, Double Rod. How to Order. Cushion C Rubber bumper. Action. D Double acting

Compact Cylinder: Large Bore Size Type Double Acting, Double Rod. How to Order. Cushion C Rubber bumper. Action. D Double acting Compact Cylinder: Large Bore Size Type Double Acting, Double Rod Series CQ2W ø, ø, ø, ø, ø Without auto switch With auto switch B Built-in magnet CQ2WB CDQ2WB Double rod ounting style Through-hole/Both

More information

Series MXH. Compact Slide. ø6, ø10, ø16, ø20

Series MXH. Compact Slide. ø6, ø10, ø16, ø20 CAT.EUS-12 B -UK Compact Slide Series MXH ø, ø, ø1, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Made to Order -XB13:

More information

Compact Type Dual-Rod Cylinder

Compact Type Dual-Rod Cylinder CAT.ES-74 A Compact Type Dual-Rod Cylinder ø, ø, ø2, ø32 additionally released. Series CXSJ /ø, ø0, ø, ø, ø2, ø32 Auto switches can be installed from 3 directions. Reverse mounting Dimensions/Weight Overall

More information

Series MLGP. Low Profile Guide Cylinder with Lock. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

Series MLGP. Low Profile Guide Cylinder with Lock. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 CAT.ES-4 A Low Profile Guide Cylinder with Lock Series MLGP,,,, ø,,, ø0 Drop prevention when supply pressure falls or residual pressure is released Drop prevention for press fitting jig Drop prevention

More information

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32 Slide Unit CX/M/L Series Slide Bearing/CX:ø0, ø, ø5 M:ø0, ø, ø0, ø5, ø3 Ball Bushing Bearing/L:ø0, ø, ø0, ø5, ø3 Provided with shock absorbers to absorb impact and noise. The slide unit can absorb energy

More information

MGZ. Non-rotating Double Power Cylinder. Double Power Cylinder MGJ MGP MGPW MGQ MGG MGC MGF MGT D- -X

MGZ. Non-rotating Double Power Cylinder. Double Power Cylinder MGJ MGP MGPW MGQ MGG MGC MGF MGT D- -X Non-rotating Double Power Cylinder Double Power Cylinder (without non-rotating Series Series R mechanism) 23 MGJ -Z W MGQ MGG MGC MGF MGT D- -X Tube rod diameter External dimension Non-rotating Double

More information

Non-rotating Double Power Cylinder. Double Power Cylinder MGZ. (without non-rotating MGJ MGP -Z MGP MGPW MGQ MGG MGC MGF MGT D- -X

Non-rotating Double Power Cylinder. Double Power Cylinder MGZ. (without non-rotating MGJ MGP -Z MGP MGPW MGQ MGG MGC MGF MGT D- -X Non-rotating Double Power Cylinder Double Power Cylinder (without non-rotating Series Series R mechanism) MGJ -Z W MGQ MGG MGC MGF MGT 23 D- -X Non-rotating Double Power Cylinder Double extension output

More information

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8 Precision Cylinder Series, ø, ø6, ø, ø, ø, ø MXS Series Variations Model 8 Standard stroke (mm) 7 7 Rod end configuration Cushion Rubber bumper End lock Made to Order Rod Variable stroke/ through-hole

More information

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping.

Dual rod cylinder with guide function suitable for pick & place applications. Adjustable stroke range: 0 to 5 mm. Axial foot piping. Dual Rod Cylinder J/ Series ø, ø, ø, ø, ø, Dual rod cylinder with guide function suitable for pick & place applications. Ball bushing bearings and slide bearings are standard for all series. Dimensions

More information

Series CE2. Brake mechanism added to a stroke reading cylinder which can measure stroke length. Stroke Reading Cylinder with Brake

Series CE2. Brake mechanism added to a stroke reading cylinder which can measure stroke length. Stroke Reading Cylinder with Brake Stroke Reading Cylinder with Brake Series ø, ø, ø, ø, ø Brake mechanism added to a stroke reading cylinder which can measure stroke length. RS A H C G5-S -12-43 Stroke Reading Cylinder with Brake/ Controller/CEU2

More information

Mini Free Mount Cylinder

Mini Free Mount Cylinder Mini Free Mount Cylinder ø, ø, ø, ø, ø, ø1, ø Series CUJ Added ø, ø1, ø bore sizes. Action Double acting Double acting Double acting Double acting Double acting Stroke 1 2 30 3 0 0 Clean series : New additions

More information

Compact Guide Cylinder with Lock

Compact Guide Cylinder with Lock Compact Guide Cylinder with Lock Series,,,, ø,,, ø0 CLG CL CN2 MLC Drop prevention when the pressure of air source is decreased or the residual pressure is released. Drop prevention for press fitting jig

More information

Series CLS. Cylinder with Lock. ø125, ø140, ø160, ø180, ø200, ø250

Series CLS. Cylinder with Lock. ø125, ø140, ø160, ø180, ø200, ø250 CT.EUS-134 C -UK Cylinder with Lock Series CLS ø, ø, ø, ø, ø, ø locking cylinder ideal for intermediate stops, emergency stops and drop prevention. Small switches can also be mounted. Manual unlocking

More information

CAT.ES20-53 E. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New:

CAT.ES20-53 E. Dual-Rod Cylinder. Series CXS. CXS Dual-Rod Cylinder with Air Cushion Compact Type Series CXSJ. New: CAT.ES-3 E Dual-Rod Cylinder Series New: Dual-Rod Cylinder with Air Cushion Compact Type Series J Dual-Rod Cylinder with guide function for pick-and-place applications Series! Twice the thrust Non-rotating

More information

Mini Rotary Actuator/Rack & Pinion Style

Mini Rotary Actuator/Rack & Pinion Style Mini Rotary Actuator/Rack & Pinion Style Series CRJ :, CRB2 CRBU2 CRB MSU CRJ CRA CRQ2 MSQ MSZ CRQ2X MSQX MRQ PAT. PEND D- 79 Mini Rotary Actuator Series CRJ Rack & Pinion Style/:, Compact 9.5 23.5 43(54)

More information

Series CLS. Cylinder with Lock. ø125, ø140, ø160, ø180, ø200, ø250

Series CLS. Cylinder with Lock. ø125, ø140, ø160, ø180, ø200, ø250 CT.ES-134 C Cylinder with Lock Series CLS ø, ø, ø, ø, ø, ø locking cylinder ideal for intermediate stops, emergency stops and drop prevention. Small switches can also be mounted. emergency stops and locking

More information

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V

How to Order M9BW. Action. Double acting Single acting. Load voltage Electrical entry direction M9NWV M9NW 12 V 5 V, M9BWV M9BW 12 V 12 V Angular Type Air Gripper/Standard Type 2 Series ø, ø1, ø20, ø25 How to Order Angular type air gripper 2 20 Bore size mm 1 1 mm 20 20 mm 25 25 mm D S Action D Double acting Single acting M9BW Made to Order

More information

Series MGC ø20, ø25, ø32, ø40, ø50

Series MGC ø20, ø25, ø32, ø40, ø50 Compact Guide Cylinder Series MGC ø, ø, ø, ø, ø Linear Transfer Unit with compact guide body and front plate Grease nipple offers easy lubrication for bearings Compact front plate and guide body Space

More information

/ ø6, ø10, ø16, ø20 A table cylinder suitable for short pitch mounting

/ ø6, ø10, ø16, ø20 A table cylinder suitable for short pitch mounting roduces a table cylinder non-rotating accuracy MXH / ø, ø, ø1, ø A table cylinder suitable for short pitch mounting Application example Auto switches offer numerous variations Reed switches, solid state

More information

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight Compact Guide Cylinder ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 RoHS Compact Overall length shortened New s ø80, ø100 added. Port thread types NPT, G added. Height shortened JMGP ø32 25 mm stroke

More information

Mini Rotary Actuator/Rack & Pinion Style

Mini Rotary Actuator/Rack & Pinion Style Mini Rotary Actuator/Rack & Pinion Style Series CRJ :, CRB2 CRBU2 CRB MSU CRJ CRA CRA CRQ2 MSQ MSZ CRQ2X MSQX MRQ PAT. PEND D- 79 Mini Rotary Actuator Series CRJ Rack & Pinion Style/:, Compact 9.5 23.5

More information

Air Slide Table. Traveling parallelism: mm. Mounting from the through-holes on the top. Tapped for mounting a work piece

Air Slide Table. Traveling parallelism: mm. Mounting from the through-holes on the top. Tapped for mounting a work piece ir Slide Table Series Height: mm/width: mm/length: mm () Front mounting accuracy: 0.01 mm Top mounting accuracy: 0.0 mm Traveling parallelism: 0.00 mm Note 1) Note ) Integrated front mounting part and

More information

Double Power Cylinder. Non-rotating Double Power Cylinder. Series MGZ. Series MGZR (without MGJ MGP MGQ MGG MGC MGF MGZ MGT. non-rotating mechanism)

Double Power Cylinder. Non-rotating Double Power Cylinder. Series MGZ. Series MGZR (without MGJ MGP MGQ MGG MGC MGF MGZ MGT. non-rotating mechanism) Non-rotating Double Power Cylinder Series Double Power Cylinder Series R (without non-rotating mechanism) 2 Non-rotating Double Power Cylinder Double extension output power!! Our unique construction doubles

More information

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3)

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3) Slide Unit Series CX/M/L Slide Bearing/CX:ø, ø, ø5 M:ø, ø6, ø0, ø5, ø3 Ball Bushing Bearing/L:ø, ø6, ø0, ø5, ø3 Provided with shock absorbers to absorb impact and noise. The slide unit can absorb energy

More information

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43

Free Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43 CAT.EUS- B -UK Free Mount Cylinder A space-saving air cylinder with multiple surfaces capable of direct mounting. Offered in many variations. Space-saving The multiple surface direct mounted rectangular

More information

Compact Hydraulic Cylinder

Compact Hydraulic Cylinder ompact Hydraulic ylinder Series HQ HQ Series HQ HK HN HM HS H2 H Nominal pressure:. MPa ore size :,,,,,, . MPa ompact Hydraulic ylinder Double cting/single Rod Series H Q ø, ø, ø, ø, ø, ø, ø With uto Switch

More information

Series MGC ø20, ø25, ø32, ø40, ø50

Series MGC ø20, ø25, ø32, ø40, ø50 Compact Guide Cylinder Series MGC ø, ø, ø, ø, ø Linear Transfer Unit with compact guide body and front plate Grease nipple offers easy lubrication for bearings Compact front plate and guide body Space

More information

Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing. How to Order CY1L 25 H 300 J79W. Load voltage 5 V 200V 100 V 12 V 5 V, 12 V

Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing. How to Order CY1L 25 H 300 J79W. Load voltage 5 V 200V 100 V 12 V 5 V, 12 V Magnetically Coupled Rodless Cylinder Slider Type: all ushing earing Series CY1L ø, ø, ø, ø, ø, ø, ø How to Order CY1L H 00 J79W Slider type (all bushing bearing) mm mm mm mm mm mm mm Magnetic holding

More information

ISO 6431/CETOP RP43P/VDMA

ISO 6431/CETOP RP43P/VDMA ISO/VDMA Cylinder Series C ø, ø0, ø, ø, ø, ø0, ø, ø60, ø0, ø Conforming to ISO /CETOP RP3P/VDMA 6 (Made to Order) C CP C76 C8 C 6- ISO Cylinder/Standard: Double Acting with Positioner Series CP ø, ø, ø,

More information

Air Cylinder. New RoHS. Series CJ2. are. added to the mounting types. Improved amount of mounting freedom Head cover with boss is added.

Air Cylinder. New RoHS. Series CJ2. are. added to the mounting types. Improved amount of mounting freedom Head cover with boss is added. ir Cylinder ø1, ø16 Double foot Double-side bossed added to the mounting types. 4 types 7 types Improved amount of mounting freedom Head cover with boss is added. Head flange are Double foot Double-side

More information

Compact Cylinder/Plate type

Compact Cylinder/Plate type Compact Cylinder/Plate type Series :,,, Width: Reduced by up to % (compared with SMC series) Total length: Reduced by up to % Volume: Reduced by up to 1% Weight: Reduced by up to % (compared with SMC series

More information

Guide Cylinder/Compact Type

Guide Cylinder/Compact Type Guide Cylinder/Compact Type Series ø, ø, ø, ø, ø Integration of guide rods and a base cylinder ir cushion is standard. Enables the impact to be absorbed at the stroke end when the cylinder is operated

More information

22 mm Space required between the bottom of the cylinder body and your equipment is reduced. 24% Up to. Compact Guide Cylinder.

22 mm Space required between the bottom of the cylinder body and your equipment is reduced. 24% Up to. Compact Guide Cylinder. Compact Guide Cylinder Series ø2,,, ø2,,, ø, ø63,, ø0 Up to Weight reduced by up to 24% with a shorter guide rod and thinner plate 24% Weight reduced! 3 types of bearing can be selected. Slide bearing

More information

Series MY1 W. Mechanically Jointed Rodless Cylinder with Protective Cover. ø16, ø20, ø25, ø32, ø40, ø50, ø63

Series MY1 W. Mechanically Jointed Rodless Cylinder with Protective Cover. ø16, ø20, ø25, ø32, ø40, ø50, ø63 CT.ES- -UK Mechanically Jointed Rodless Cylinder with Protective Cover Series MY W ø, ø, ø, ø, ø, ø, ø Introducing our mechanically jointed rodless cylinder with a superior dustproof, water-resistant protective

More information

Rotary Clamp Cylinder

Rotary Clamp Cylinder Rotary Clamp Cylinder ø, ø, ø, ø, ø, ø, ø, ø llowable moment of inertia 3 times higher New structure! New series Overall length is the same as the existing products! Mounting dimensions are interchangeable

More information

Series C96. ISO Cylinder. Conforming to ISO ø32, ø40, ø50, ø63, ø80, ø100, ø125. Variations. Standard. Standard variations Built-in magnet

Series C96. ISO Cylinder. Conforming to ISO ø32, ø40, ø50, ø63, ø80, ø100, ø125. Variations. Standard. Standard variations Built-in magnet ISO Cylinder Series C ø, ø, ø, ø, ø, ø0, ø Conforming to ISO 12 Variations Series ction Type Basic Standard variations Built-in magnet Stainless steel rod Option Heat resistant Bore Standard Series C Double

More information

3-Position Rotary Table

3-Position Rotary Table CAT.ES-187 A 3-Position Rotary Table Stop position adjustment range From center: ± Rotation range: 0~95 The desired position is adjustable to between 0 and 95 from the centered position to both the right

More information

Series MGP. Compact Guide Cylinder. New end lock type introduced to Series MGP. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

Series MGP. Compact Guide Cylinder. New end lock type introduced to Series MGP. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 Compact Guide Cylinder Series ø, ø, ø, ø2, ø, ø, ø, ø, ø, ø0 New end lock type introduced to Series.22- CL MLG CN CNG MNB CNS CLS CB CV/MVG CXW CXS CXT MX MXU MXH MXS MXQ MXF MXW MXP MG MGQ MGG MGC MGF

More information

Series MHSL3. How to Order F9N. Auto switch type. Nil Without auto switch (bulit-in magnet) Auto switch specifications. Type. Solid state.

Series MHSL3. How to Order F9N. Auto switch type. Nil Without auto switch (bulit-in magnet) Auto switch specifications. Type. Solid state. inger Air ripper arallel Type Cylinder Bore Size ø1 to ø Series MS ø1, ø, ø, ø, ø, ø, ø, ø, ø1, ø1 MS ow to Order D N finger MS finger MS Cylinder Bore Size ø to ø1 Symbol Number of fingers fingers Number

More information

Air Slide Table. Traveling parallelism: mm. Mounting from the through-holes on the top. Tapped for mounting a work piece

Air Slide Table. Traveling parallelism: mm. Mounting from the through-holes on the top. Tapped for mounting a work piece ir Slide Table Series Height: mm/width: mm/length: mm () Front mounting accuracy: 0.01 mm Top mounting accuracy: 0.0 mm Traveling parallelism: 0.00 mm Note 1) Note ) Integrated front mounting part and

More information

Series MXY. Air Slide Table Long Stroke. ø6, ø8, ø12. A long-stroke type of Series MXP air slide table with integrated linear guide is newly released.

Series MXY. Air Slide Table Long Stroke. ø6, ø8, ø12. A long-stroke type of Series MXP air slide table with integrated linear guide is newly released. CAT.ES0-17 A -UK Air Slide Table Long Stroke Series MXY ø, ø8, ø1 MXP A long-stroke type of Series MXP air slide table with integrated linear guide is newly released. Use of linear guide provides rigid,

More information

Free Mount Cylinder. Series CU. A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations.

Free Mount Cylinder. Series CU. A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations. Free Mount Cylinder Series CU A space-saving air cylinder with multiple surfaces capable of mounting directly. Offered in rich variations. Space-saving The multiple surface direct mounting with a square

More information

Dual rod cylinder with guide function for pick & place applications.

Dual rod cylinder with guide function for pick & place applications. Dual Rod Cylinder Series CXS ø, ø0, ø, ø, ø2, Dual rod cylinder with guide function for pick & place applications. Series CXS Twice the thrust Non-rotating accuracy ±0. MX MY CY MG CX - Ball bushing bearings

More information

How to Order D 30 D M9BW. Made to Order Specifications Bore size Number of. Rod end configuration Cylinder stroke (mm) Nil

How to Order D 30 D M9BW. Made to Order Specifications Bore size Number of. Rod end configuration Cylinder stroke (mm) Nil With auto switch RSG RSDG With auto switch (uilt-in magnet) uilt-in Magnet Cylinder Model If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the

More information

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space Compact Rotary Actuator Series CR2 Rack Pinion Style/:,,,, Piping can be installed from one end Uses internal cushioning, : Rubber bumper,, : Air cushion Angle adjustment bolts are standard Use of double

More information

Parallel Style Air Gripper

Parallel Style Air Gripper INFRMATIN Parallel tyle Air Gripper With Dust Cover Model variations with excellent dust proof and drip proof dust cover are expanded. MHZL2 Long stroke type MHZL2 series ø1, ø16 and ø2 with dust cover

More information

3 Pneumatics. Valve Mounted Cylinders CV MVGQ. Valve Mounted Cylinders. Series CVQ. Series CVJ5. Series CVJ3. Series CVM5/ CVM5K Double acting

3 Pneumatics. Valve Mounted Cylinders CV MVGQ. Valve Mounted Cylinders. Series CVQ. Series CVJ5. Series CVJ3. Series CVM5/ CVM5K Double acting Series Variations est 3 Pneumatics Valve Mounted Cylinders Valve Mounted Cylinders Series Series CVQ ction uilt-in magnet With air cushion Standard variations uilt-in One-touch fitting With auto switch

More information

Compact integration of guide rods and a fine lock cylinder with a built-in locking mechanism

Compact integration of guide rods and a fine lock cylinder with a built-in locking mechanism Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-80 www.cmafh.com Guide Cylinder Series MLGC uilt-in Fine Lock Cylinder Compact Type Compact integration

More information

Air Cylinder. New. New RoHS. 6 types. Series CJ2. are. added to the mounting types. 4 types 7 types

Air Cylinder. New. New RoHS. 6 types. Series CJ2. are. added to the mounting types. 4 types 7 types ir Cylinder Ø 6, Ø 1, Ø New RoS Double foot ead flange Double-side bossed added to the mounting types. 4 types 7 types New or Ø 6, 3 types are 6 types Double foot Double-side bossed ead flange ead cover

More information

Rotary Clamp Cylinder

Rotary Clamp Cylinder Rotary Clamp Cylinder ø, ø, ø, ø, ø, ø, ø, ø llowable moment of inertia 3 times higher New structure! New series Overall length is the same as the existing products! Mounting dimensions are interchangeable

More information

Air Cylinder: Standard Type Double Acting, Single Rod. How to Order. Standard stroke (mm) ø6 15, 30, 45, 60. Cushion Nil A

Air Cylinder: Standard Type Double Acting, Single Rod. How to Order. Standard stroke (mm) ø6 15, 30, 45, 60. Cushion Nil A ø, ø, ø L F D Without auto switch With auto switch style asic style Axial foot style Rod side flange style Double clevis style (Except ø) ore size mm mm mm How to Order Standard stroke (mm) ø,,, ø,,,,

More information

Compatible with an operating environment with coolants.

Compatible with an operating environment with coolants. Water Resistant Cylinder (Pneumatic/ydraulic) Pneumatic: CM/CG1/MB/MB1/CQ/CA/MGP/MGG Series ydraulic: CDKB/CF Series Compatible with an operating environment with coolants. CJ5 CG5 Y Water Resistant Anti-coolant

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

Compact Guide Cylinder Series MGP

Compact Guide Cylinder Series MGP Compact Guide Cylinder Series MGP ø2, ø, ø, ø, ø, ø, ø, ø,, ø0 MGJ MGP MGQ MGG MGC MGF MGZ MGT Series Variations Series Bearing type Cushion 2 0 Page Standard type MGP With air cushion MGP With end lock

More information

Compact Hydraulic Cylinder. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100. How to Order Z73. Bore size. 20mm 25mm 32mm 40mm 50mm 63mm 80mm 100mm

Compact Hydraulic Cylinder. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100. How to Order Z73. Bore size. 20mm 25mm 32mm 40mm 50mm 63mm 80mm 100mm ompact ydraulic ylinder MPa Series KG ø, ø, ø, ø, ø, ø, ø, ø0 With uto Switch With auto switch (built-in magnet) KG DKG Mounting: asic type 0 ore size ow to Order mm mm mm mm mm mm mm 0mm Z3 Refer to "uto

More information

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2 Rotary Actuator Vane Type 1, 15, 2, 3, 4 Standard Type Free Mount Type Many combinations available! Standard type/series Piping ports are located on the flat surface. Fittings can be secured firmly, piping

More information

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector Non-rotating Type High Precision Scale Cylinder Series CEP1 ø12, ø How to Order CEP1 12 0 F9N L F High precision scale cylinder Mounting bracket Direct mounting front tapped type Foot type Front flange

More information

C85 (ISO 6432) Series: ø8, ø10, ø12, ø16, ø20, ø25 C75 Series: ø32, ø40

C85 (ISO 6432) Series: ø8, ø10, ø12, ø16, ø20, ø25 C75 Series: ø32, ø40 ISO Cylinder (ISO 6432) Series: ø8, ø10, ø12, ø16, ø20, ø25 Series: ø32, ø40 RoS Part numbers set for actuators with mounting brackets, rod end brackets and auto switches available. Now it is not necessary

More information

Parallel Type Air Gripper. Series MHZ. ø6, ø10, ø16, ø20, ø25, ø32, ø40 MHZ MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ.

Parallel Type Air Gripper. Series MHZ. ø6, ø10, ø16, ø20, ø25, ø32, ø40 MHZ MHQ MHL2 MHR MHK MHS MHC2 MHT2 MHY2 MHW2 MRHQ. Parallel Type Air Gripper Series ø, ø1, ø1, ø, ø, ø3, ø MHQ MHL MHR MHK MHS Series upgraded with the addition of new models and expanded size variations Long stroke/l and compact series/a- introduced ø,

More information