Applicable Auto Switch Model

Size: px
Start display at page:

Download "Applicable Auto Switch Model"

Transcription

1 Applicable Auto Switch Model Refer to p..-2 to.- for the detailed specifications of auto switches. Applicable Auto Switch Model Reed Switch Solid State Switch Cylinder D-C/C D-CC/C0C D-B/B D-BW D-A/A D-A A/AA D-A C/AC D-A/A D-A H/A0H D-AC/A0C D-AW D-A/A D-AW D-A/A V D-/ A D-E A/E0A D-Z/Z D-H D-HC D-HBAL D-H F D-H W D-G/K D-GBAL D-GF D-GNTL D-G W/KW D-G/K D-GA/KA D-F/J D-JC D-F F D-FBAL D-F V D-FNTL D-F W(V) D-F/J D-FBAL D-F W/JW D-F F D-FNTL D-GC/KC D-F/F V D-F W/F WV D-FBAL D-Y/Y/Y /Y V D-YBAL D-Y W/Y WV D-M D-M W D-M TL D-P WL CDJ2/RSD CDJP CDU CDQ2 CDQS MDU/CDE1 CDM2 CDG1 CDA1/CDNA/CE2 MDB/MDBB CDS1 CDL CDB CDV CD X CDY1 MY1 ML1/ML2 MX/MTS CXS MGG/MGC/MLGC MGQ/MGF/MGP/MVGQ MK/MK2 RSH RHC/REC Mounting method Band Rail Tie-rod Direct Function 2 color 2 colour 2 colour Water resistance Diagnosis output 2 colour Water resistance Diagnosis output With timer 2 colour Diagnosis output Water resistance With timer 2 colour Water resistance 2 colour Diagnosis output With timer 2 colour Water resistance Water resistance 2 colour 2 colour With timer Magnetic resistance Page / / / / / / Note 1) D-B/B, D-BC/B0C, D-G/K and D-KC are applicable for series MGG, MGC and MLGC. Note 2) MXS, MXF, MXP, MXQ, MXW and MXU are included in MX..-1

2 Auto Switch Guide Reed Switch Solid State Switch Reed Switch P.- General Purpose Style P.- Band, Rail, Tie-rod, Direct mounting 2 Colour Indication Style P.-2 Band, Rail, Tie-rod Mounting Solid State Switch P.-2 RB General Purpose Style P.-2 Band, Rail, Tie-rod, Direct mounting 2 Colour Indication Style P.-2 Band, Rail, Tie-rod, Direct mounting 2 Colour Indication Style with Diagnostic Output P.- Band, Rail, Tie-rod Mounting Water Resistant 2 Colour Indication Style P.- Band, Rail, Tie-rod, Direct mounting With Timer P.- Band, Rail, Tie-rod, Direct mounting Strong Magnetic Field Resistant 2 Colour Indication Style P..- Rail Mounting J D -X 20- Technical Data.-2

3 SMC Auto Switch Variations Mounting Function Style method Electrical entry Auto switch model No. Page D-C/C/C0 D-B/B/B.-.- Connector D-CC/C0C.- Band Terminal conduit D-A/A D-AA/AA.-.- DIN terminal D-A D-AA.-.- General purpose auto switch Rail Tie-rod Direct Band Connector Terminal conduit DIN terminal Connector D-A2/A/A0 D-A2H/AH/AH/A0H D-AC/A0C D-A/A/A/A/A D-AC/AC D-AC D-A0/A/A D-A0V/AV/AV D-0/ D-0A/A D-Z/Z/Z0 D-EA/EA/E0A D-HA1/HA2/HB D-G/GP/K D-HC Solid state switch Rail Tie-rod Direct Terminal conduit Connector Terminal conduit D-G/K D-GA/KA D-F/FP/J D-FNV/FPV/FBV D-JC D-F/FP/J/J1 D-GC/KC D-MN/MP/MB D-MNV/MPV/MBV D-YA/YP/YB D-YA/YPV/YB D-MN/MP/MB.-1 General purpose auto switch.- Band mounting Rail mounting Tie-rod mounting Direct mounting

4 SMC Auto Switch Variations Mounting Function Style Electrical entry Auto switch model No. Page method The suitable operating point can be indicated with green light. (Red Green Red) 2 colour indication style 2 colour indication style with diagnostic output Reed switch Solid state switch Band Rail Tie-rod Band Rail Tie-rod Direct The output signal can be detected in an unsteady detecting area. Water resistant 2 colour indication Solid state switch Band Rail Tie-rod Water (coolant) resistant performance With timer Solid state switch Band Rail Tie-rod Direct With built-in OFF-delay timer (200ms) Solid state switch Band Rail Tie-rod Direct D-BW D-AW D-AW D-HNW/HPW/HBW D-GW/GPW/KW D-FW/FPW/JW D-FNWV/FBWV D-FW/FPW/JW D-MNW/MPW/MBW D-YNW/YPW/YBW D-YNWV/YPWV/YBWV D-FNW/FPW/FBW D-FNWV/FPWV/FBWV D-HLF (Latching style) D-HNF D-GF D-FLF (Latching style) D-FF D-FLF (Latching style) D-FF D-HBAL D-GBAL D-FBAL D-FBAL D-YBAL D-FBAL D-GNTL D-FNTL D-FNTL D-MNTL/MPTL Possible to use in an environment where disturbance magnetic fields are generated RB J D -X 20- Technical Data Strong magnetic field resistant Solid state switch 2 colour indication Rail D-PDWL 2 colour indication with diagnostic output Water resistant 2 colour indication With timer.-.-

5 Prior to Use Auto Switch Precautions Refer to "Auto Switch Precautions" in p.0- to 0- before handling. Auto Switch Common Auto switch style Operating time Shock resistance None 1.2ms 00m/s 2 Solid state switch wire: 0 µa or less, : 1mA or less 1ms or less () 00m/s 2 Insulation resistance 0 M Ω or more at 00MV DC (between lead wire and the case) Withstand voltage Ambient temperature 0V AC/min. (between lead wire and the case) (1) to 0 C 00V AC/min. (between lead wire and the case) Protective construction IEC2 Standard IP, Waterproof construction (JISC020) (2) Note 1) Connector style (D-AC/A0C/CC/C0C) and D-/ A/A/A V style: 00V AC/min. (between lead wire and the case) Note 2) IEC2 Standard IP, Rainproof construction (JISC020) for Terminal conduit style (D-A/A A/A C/G/GA/GC/K/KA/KC) and DIN teminal style (D-A/AA/AC). Note ) Except solid state switch with timer (D-M TL, GNTL, FNTL, FNTL) and Auto switch for strong magnetic field resistance (D-PDWL). D-J1: ms or less Lead Wire Length How to Order Ex.).- D-A L Lead wire length 0.m L m Z N m None Applicable for the connector style (D- C) only Note 1) Applicable auto switch with meter lead wire ("Z") : D-B/B, D-C (C)/C0C,D-A(C)(H)/A0C D-A/A, D-Z, D-0//0A/A Solid state switch: Manufactured upon receipt of order as standard (Except D-F/F V) Note 2) The standard lead wire length of solid state switch with timer or with water resistant 2 colour indication is meters. (Not available 0.m) Note ) The standard lead wire length of strong magnetic field resistant solid state switch is or meters. (Not available 0.m.) Part No. of lead wire with connector (Available for connector style only.) Part No. Lead wire length D-LC0 0.m D-LC0 m D-LC0 m Change of Lead Wire Colour Lead wire colours of SMC auto switches have been changed in order to meet Nippon Electric Control Equipment Industries Association Standard No. 02. auto switch wire auto switch Output (+) Output ( ) Power supply Old Red Black Old Red New Brown Blue Solid state auto switch with diagnostic output New Brown GND Black Blue Output White Black Diagnositc Yellow output Orange Power supply GND Old Red Black New Brown Blue Output White Black Solid state auto switch with latching style diagnostic output Power supply GND Old Red Black New Brown Blue Output White Black Latching style diagnostic outout Yellow Orange

6 Prior to Use Auto Switch Hysteresis/Contact Protection Box Contact Protection Box/CD-P, CD-P 1 The following auto switches are not incorporated with the contact protection box. D-A/A, D-A H/A0H, D-AC, A0C, D-C/C, D-CC/C0C, D-E A, E0A, D-Z/Z, D-/ A, D-A/A V, and D-AW type Use an auto switch with a contact protection box in any case listed below. Unless using a contact protection box, the contact life may be shortened. (Due to permanent energizing conditions.) D-A2(H) must be used with the contact protection box regardless of load styles and lead wire length. qoperating load is an inductive load. wthe wiring length to load is more than m. ethe load voltage is 0 or 200 V AC. 2 Contact SMC when using built-in contact protection style (D-A[A] [C], D-A[A] [C], D-A/A, D-B/B, D-AW, D-BW) in the following conditions: q The wiring length to load is more than 0m. w When using PLC with large flow current Contact Protection Box/ ( ): If applicable for IEC Standard CD-P CD-P Contact Protection Box/ Contact Protection Box/ Part No. CD-P 0V AC max. 200V AC Max. load current 2mA.mA Lead wire length - Switch connecting side 0.m Load connecting side 0.m CD-P 2V DC 0mA Auto Switch Hysteresis The distance between the turn-on point (ON) of the switch by moving of the piston to the turn-off point (OFF) is called "Hysteresis". This hysteresis is included as part of the operating range (one side). Contact Protection Box/Connection Method For connection of the switch body and the contact protection box, connect the lead wire in the side indicated as "SWITCH" on the contact protection box to the lead wire from the switch body. The length of lead wire between the switch body and the contact protection box should be within 1m and they should be set as close together as possible. RB J D -X 20- Technical Data Switch turn-on point (ON) The difference between the turn-on point (ON) and the turn-off (OFF) is 2mm or less in a reed switch and 1mm or less in a solid state switch. Switch turn-off point (OFF) Note) Hysteresis may fluctuate due to the operating environment. Contact SMC if the hysteresis causes a problem..-

7 Prior to Use Auto Switch Connection Method/Connection Example Basic Solid state switch wire NPN Switch main Brown Load Black wire PNP Switch main ciruit Brown Black Load Switch main ciruit Brown Load Indicator protective Brown Load Blue (When power source for switch and load is not common.) Brown Blue Blue Brown Blue Brown Switch main Load Black Blue Switch main ciruit Load Blue Indicator protective Load Blue Typical PLC (Programmable Logic Controller) Connection Circuits Sink input wire NPN Black IN Source input wire PNP Black IN Connect according to the input specification of PLC because the connection method varies with the input specification of PLC. Switch Brown Switch Brown Blue Blue COM PLC internal Brown IN Blue COM IN PLC internal Switch Switch Blue COM PLC internal Brown COM PLC internal AND (Serial), OR (Parallel) Connection Examples wire NPN/AND connection (with relay) NPN/AND connection (with switch) NPN/OR connection Switch 1 Switch 2 Brown Black Relay Blue Brown Black Blue Relay Load Relay contact Switch 1 Switch 2 Brown Black Blue Brown Black Blue Load Switch 1 Switch 2 Brown Black Blue Brown Black Blue Load Indication lights up when both switches are ON. (2 pcs.) AND connection Switch 1 Switch 2 Brown Blue Brown Blue Load When 2 switches are connected by AND, load voltage will decrease at ON and these connections may cause malfunction of load. Indication lights up when both switches are ON. at ON=Supply voltage-internal drop voltage X 2 pcs. =2V-V X 2 pcs. =1V Example) Supply voltage 2V DC, switch internal drop voltage V OR connection [Solid state switch] When 2 switches are connected by OR, load voltage will Brown Load increase at OFF and these connections may cause Switch 1 malfunction. Blue [] There is no current leakage so that load voltage does not in- Brown crease at OFF. Switch 2 The flowing current is broken up into the ON-state switches, Blue so indicator light becomes dark or may not turn ON due to the lack of the current. at OFF=Leakage current X 2 pcs. X Load impedance =1mA X 2 pcs. X kω =V Example) Load impedance kω, switch leakage current 1mA.-

8 Reed Switch General Purpose Auto Switch 2 colour Indication Style Reed Switch Variations Mounting Style Function Electrical entry Auto switch model No. Page method General purpose auto switch Band Rail Tie-rod Direct Connector Terminal conduit DIN terminal Connector Terminal conduit DIN terminal D-C/C/C0 D-B/B/B D-CC/C0C D-A/A D-AA/AA D-A D-AA D-A2/A/A0 D-A2H/AH/AH/A0H D-AC/A0C D-A/A/A/A/A D-AC/AC D-AC D-A0/A/A D-A0V/AV/AV D-0/ D-0A/A P colour indication Band Rail Tie-rod D-Z/Z/Z0 D-EA/EA/E0A D-BW D-AW D-AW RB J D -X 20- Technical Data.-

9 Reed Switch/Band Mounting D-C/D-C/D-C0 Applicable Actuator CDJ2 CDVJ CDLJ2 CDM2/CDBM2/CDVM, CDLM2 CDG1/MGG CDLG1 RSDG MGC MLGC/RHC/REC ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0 ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-C D-C (With indicator light) D-C Relay/PLC D-C IC Max. load current and range Contact protection 2V DC to 0mA 0V AC to 20mA None to V DC 20mA 2.V 0.V D-C (Without indicator light) ON: When red light emitting diode D-C0 Relay/PLC/IC AC 2V DC or less AC V DC AC 0V DC Max. load current 0mA 0mA 20mA Contact protection None Internal resistance 1Ω or less (Including m lead wire) Lead wire - Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. LED Resistance Zener diode Contact protective box CD-P CD-P (+) ( ) D-C LED (+) Resistance Black Load Reverse flow prevent diode Blue ( ) D-C0 Contact protective box CD-P CD-P (±) ( ) Note) q In the case operation load is an inductive load. w In the case the wiring length to load is more than m. e In the case the load voltage is 0V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box. ± CDJ2 CDVJ CDLJ2 CDM2/CDBM2/CDVM, /CDLM2 CDG1/MGG CDLG1 RSDG MGC MLGC/RHC/REC Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%)

10 Reed Switch/Band Mounting D-B/D-B/D-B Applicable Actuator CDM2, CDBM2, CDVM/, CDLM2 CDG1, MGG CDLG1 CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CE2, CNA MGC MLGC, RHC, REC ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-B ( ) D-B LED Zener diode Zener diode Resistance Choke coil Resistance ( ) ~ LED (+) Brown (Red) (+)~ Brown (Red) D-B (With indicator light) D-B range Contact protection D-B (Without indicator light) Max. load current Contact protection Internal resistance PLC 2V DC to 0mA None 2.V AC 2V DC or less Max.0mA Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-B Relay/PLC 2V DC 0V AC to 0mA to 2mA Built-in 2.V ON: When red light emitting diode D-B Relay/PLC 0V AC Max.2mA Built-in Ω or less 200V AC to.ma 200V AC Max..mA RB J D -X 20- Technical Data Surge absorber D-B ( ) ~ ± Surge absober Choke coil (±)~ Brown (Red) CDM2, CDBM2, CDVM, CDLM2 CDG1, MGG CDLG1 CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CE2, CNA MGC MLGC, RHC, REC Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%) 0 0.-

11 Reed Switch/Band Mounting D-CC/D-C0C Connector Applicable Actuator CDJ2 CDVJ CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2 CDG1, MGG CDLG1 RSDG MGC MLGC, RHC, REC ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0 ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 Caution Precautions qconfirm that the connector is appropriately tightened. If tightened insufficiently, the water resistant performance will deteriorate. wrefer to p..- for the details. D-CC LED Resistance Zener diode Contact protective box CD-P Choke coll Zener diode (+) ( ) D-CC (With indicator light) D-CC Relay/PLC 2V DC range to 0mA Contact protection None 2.V ON: When red light emitting diode D-C0C (Without indicator light) D-C0C Relay/PLC AC 2V DC Max. load current 0mA Contact protection None Internal resistance 1Ω (Including m lead wire) Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Note ) Lead wire with connector may be shipped with switch. D-C0C.- Contact protective box CD-P CD-P (±) to ( ) Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box. ± CDJ2 CDVJ CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2 CDG1, MGG CDLG1 RSDG MGC MLGC, RHC, REC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

12 Reed Switch/Band Mounting D-A/D-A/D-A Terminal conduit: D-A DIN terminal: D-A Applicable Actuator CDA1, CDBA1, CDV, CDVS, CDLA, CE2, CNA CDL1 CDS1 RHC ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø20, ø2, ø2, ø0 Caution Precautions quse cable whose O. D. is within the size in the figure to maintain water resistant performance. wafter wiring, confirm that tightening gland and all screws are tightened. D-A ( ) 2nd terminal D-A, D-A ( ) to 2nd terminal LED Resistance Zener diode Choke coil LED Resistance Zener diode Surge absorber (+) 1st terminal (+) to 1st terminal D-A (With indicator light) Terminal conduit D-A D-A PLC Relay/PLC 2V DC 2V DC 0V AC 200V AC range to 0mA to 0mA to 2mA to.ma Contact protection None Built-in 2.V ON: When red light emitting diode D-A (With indicator light) DIN terminal D-A 2V DC range to 0mA Contact protection Note) Refer to common specifications on p..-. D-A D-A Relay/PLC 0V AC 200V AC to 2mA to.ma Built-in 2.V ON: When red light emitting diode RB J D -X 20- Technical Data CDA1, CDBA1, CE2 CDV, CDVS, CDLA CNA CDL1 CDS1 RHC Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%)

13 Reed Switch/Band Mounting D-AA/D-AA/D-AA Terminal conduit: D-A A DIN terminal: D-AA Applicable Actuator CDM2, CDBM2, CDLM2 ø20, ø2, ø2, ø0 D-AA, D-AA ( ) to 2nd terminal D-AA ( ) 2nd terminal D-A A Choke coil LED Resistance Zener diode Surge absorber LED Resistance Zener diode (+) to 1st terminal (+) 1st terminal D-A A (With indicator light) Terminal conduit D-AA D-AA range Contact protection 2V DC to 0mA Relay/PLC 0V AC to 2mA Built-in 200V AC to.ma 2.V PLC 2V DC to 0mA None ON: When red light emitting diode D-AA (With indicator light) DIN terminal range Contact protection 2V DC to 0mA D-AA Relay/PLC 0V AC to 2mA Built-in 2.V 200V AC to.ma ON: When red light emitting diode Note) Refer to common specifications on p..-. Caution Precautions quse cable whose O. D. is within the size in the figure to maintain water resistant performance. D-AA wafter wiring, confirm that tightening gland and all screws are tightened CDM2, CDBM2, CDLM2 Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%).-

14 Reed Switch/Rail Mounting D-A2/D-A/D-A0 Electrical entry : Perpendicular Applicable Actuator CDJ2, CDVJ CDQ2 CDXW CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Plate mounted ø, ø1, ø20, ø2, ø2, Housing mounted ø1, ø20, ø2, ø2 ø, ø, ø1, ø20, ø2, ø2, ø0 ø1, ø20, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 D-A2 D-A D-A0 LED Resistance Zener diode Contact protection box CD-P LED Contact Resistance protection box Zener diode CD-P CD-P Contact protection box CD-P CD-P Choke coil Surge absorber (+) Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. ein the case the load voltage is 0 or 200V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. D-A2 must be used with contact protection box. Refer to p..- for the details of contact protection box. to (±) to ( ) ± to ( ) D-A (With indicator light) D-A2 D-A Relay/PLC Relay/PLC 200V AC 2V DC 0V AC range to ma to 0mA to 20mA Contact protection None 2.V ON: When red light emitting diode D-A (Without indicator light) D-A0 Relay/IC /PLC AC 2V DC or less V AC DC 0V AC DC Max. load current 0mA 0mA 20mA Contact protection None Internal resistance 1Ω or less (Including m lead wire) Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on the p..-. Note 2) Refer to the p..- for lead wire length. CDJ2, CDVJ CDQ2 B CDXW P CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%) RB J D -X 20- Technical Data

15 Reed Switch/Rail Mounting D-A H/D-A0H Electrical entry : In-line D-A2H D-AH LED Resistane Zener diode Contact protection box CD-P Choke coil Surge absorber LED Contact Resistance protection box Zener diode CD-P CD-P to (+) to ( ) Applicable Actuator CDJ2, CDVJ CDQ2 CDXW CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Plate mounted ø, ø1, ø20, ø2, ø2, Housing mounted ø1, ø20, ø2, ø2 D-A H (With indicator light) D-A2H Max. load current and range Contact protection Relay/PLC 200V AC to ma D-A0H (Without indicator light) s ø, ø, ø1, ø20, ø2, ø2, ø0 ø1, ø20, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 2V DC to 0mA 2.V ON: When red light emitting diode AC 2V DC or less D-AH Relay/PLC None D-A0H 0V AC to 20mA Relay/IC /PLC V AC DC D-AH IC to V DC 20mA 0.V or less 0V AC DC Max. load current Contact protection Internal resistance 0mA 0mA None 1Ω or less (Including m lead wire) 20mA Lead wire Oilproof vinyl heavy insulation cable, 0.2mm 2, 2 cores (Brown, Blue), cores (Brown, Black, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-AH LED (+) D-A0H Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. ein the case the load voltage is 0 or 200V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. D-A2H must be used with contact protection box. Refer to p..- for the details of contact protection box..-1 Resistance Reverse flow prevent diode Load Contact protection box CD-P CD-P (DC) ( ) (±) to ( ) ± CDJ2, CDVJ CDQ2 B CDXW P CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%)

16 Reed Switch/Rail Mounting D-AC/D-A0C D-AC Connector Caution Precautions qconfirm that the connector is appropriately tightened. If tightened insufficiently, the water resistant performance will deteriorate. wrefer to p..- for the details. Contact protection box CD-P LED Choke coil (+) Resistance Zener Zener diode diode ( ) Applicable Actuator CDJ2, CDVJ CDQ2 CDXW CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Plate mounted ø, ø1, ø20, ø2, ø2, Housing mounted ø1, ø20, ø2, ø2 ø, ø, ø1, ø20, ø2, ø2, ø0 ø1, ø20, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 D-AC (With indicator light) D-AC Relay/PLC 2V DC range to 0mA Contact protection None 2.V ON: When red light emitting diode D-A0C (Without indicator light) D-A0C Relay/IC /PLC 2V AC DC Max. load current 0mA Contact protection None Internal resistance 1Ω or less (Including m lead wire) Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Note ) Lead wire with connector may be shipped with switch. RB J D -X 20- Technical Data D-A0C Contact protection box CD-P CD-P (±) to ( ) Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box. ± CDJ2, CDVJ CDQ2 B CDXW P CDY1S CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%)

17 Reed Switch/Tie-rod Mounting D-A /D-A Applicable Actuator CDA1, CDBA1, CDV, CDVS, CDLA, CE2, CNA CDL1 CDS1 MDB, MDBB ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø2, ø0, ø0, ø, ø0, ø0 D-A (With indicator light) D-A Max. load current and range Contact protection PLC 2V DC to 0mA None D-A (Without indicator light) Max. load current Contact protection 2V AC DC 0mA 2V DC to 0mA PLC: Programmable Logic Controllar D-A Relay/PLC 0V AC to 2mA Built-in 200V AC to.ma 2.V ON: When red light emitting diode D-A Relay/PLC 0V AC 2mA Built-in 200V AC.mA D-A IC to V DC 20mA None 0.V or less D-A PLC/IC MAX. 2V DC 0mA None D-A ( ) LED Resistance (+) Internal resistance Ω Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), 0.m or ø, 0.2mm 2, cores (Brown, Black, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. 1Ω (Including m lead wire) Zener diode D-A ( ) to Zener diode LED Resistance Choke coil (+) to D-A LED Surge absorber Resistance Reverse flow prevent diode Load (+) ( ) D-A ( ) to ± D-A ( ) ± Surge absorber Choke coil (±) (±) to CDA1, CDBA1, CDV, CNA, CDVS, CDLA, CE CDL1 CDS1 MDB, MDBB Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%)

18 Reed Switch/Tie-rod Mounting D-AC/D-AC/D-AC Terminal conduit: D-A C DIN terminal: D-AC Applicable Actuator CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CE2, CNA ø0, ø0, ø, ø0, ø0 D-AC (-) 2nd terminal D-AC, D-AC (-) to 2nd terminal LED LED Resistance Zener diode Surge absorber Resistance Zener diode Choke coil D-A C (+) 1st terminal (+) to 1st terminal D-A C (With indicator light) Terminal conduit range Contact protection D-AC PLC 2V AC to 0mA None 2V DC to 0mA D-AC Relay/PLC 0V AC to 2mA Built-in 200V AC to.ma 2.V ON: When red light emitting diode D-AC (With indicator light) DIN terminal range Contact protection 2V DC to 0mA D-AC Relay/PLC 0V AC to 2mA Built-in 2.V 200V AC to.ma ON: When red light emitting diode Note) Refer to common specifications on p..-. Caution Precautions quse cable whose O. D. is within the size in the figure to maintain water resistant performance. wafter wiring, confirm that tightening gland and all screws are tightened. D-AC RB J D -X 20- Technical Data CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CNA Note) Average value at normal temperature including hysteresis. (Tolerance ± 0%) Switch part No. D-A C-, D-AC- D-A C-, D-AC- D-A C-, D-AC- D-A C-, D-AC- D-A C-, D-AC- ( ): Values for D-AC C 2 2 HW 1 1 H (.) (.) 1.(1) (.) (.) H' 0.(0) 1.(1) (2.).().() T T'..... Z M X 1 M X 20 M X 2.-1

19 Reed Switch/Direct Mounting D-A0/D-A/D-A Electrical entry: In-line D-A0 D-A D-A LED Resistance Zener diode LED Resistance Reverse flow prevent diode Load Contact protective box CD-P CD-P Contact protective box CD-P CD-P Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. ein the case the load voltage is 0V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box. (+) ( ) (±) to ( ) ± (+) to ( ) Applicable Actuator CDU ø, ø, ø1, ø20, ø2, ø2 CDQS ø, ø1, ø20, ø2 CDQ2 ø2, ø0, ø0, ø, ø0, ø0 MY1 ø1, ø20 MXU ø, ø, ø1 MXW ø, ø, ø1, ø20, ø2 MXF ø, ø, ø1, ø20 MXS/MXQ ø, ø, ø, ø1, ø20, ø2 Not applicable for CDQP2 D-A0 (Without indicator light) Auto swich modle number Max. load current Contact protection Internal resistance D-A/D-A (With indicator light) D-A Max. load current and load current range D-A0 IC /Relay/PLC AC 2V DC or less 0mA AC V DC or less 0mA AC 0V DC or less 20mA None 1Ω or less (Including m lead wire) 2V DC to 0mA Relay/PLC 0V AC to 20mA D-A IC to V DC 20mA Contact protection None 2.V (up to 20mA)/ V (up to 0mA) ON: When red light emitting diode 0.V Lead wire D-A0/D-A Oilproof vinyl heavy insulation cable, ø2., 0.1mm 2 X 2cores (Brown, Blue), 0.m D-A Oilproof vinyl heavy insulation cable, ø2., 0.1mm 2 X cores (Brown, Black, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Caution MXP MTS CXT MK MK2 RSQ CEP CY1R Precautions ø, ø, ø1 ø20, ø2, ø2, ø0 ø, ø1, ø20, ø2, ø2, ø0 ø, ø1 ø2, ø0, ø0, ø ø, ø2, ø0, ø0 ø, ø20 ø, ø, ø1, ø20 qfix the switch with appropriate screw installed on the switch body. If using other screws, switch may be damaged. ( ): D-A Actuator series CDU CDQS CDQ2 MY1 MXU MXW MXF MXS Actuator series MXQ MXP MTS CXT MK MK2 RSQ CEP CY1R Note) Average value at normal temperature including hysteresis. (Tolerance ±0%).

20 Reed Switch/Direct Mounting D-A0V/D-AV/D-AV Electrical entry: Perpendicular D-A0V D-AV LED D-AV Resistance Zener diode LED Resistance Load Reverse flow prevent diode Contact protection box CD-P CD-P Contact protection box CD-P CD-P (+) ( ) (±) to ( ) ± (+) to ( ) Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. ein the case the load voltage is 0V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box. Applicable Actuator CDU CDQS CDQ2 MY1 MXU MXW MXF MXS/MXQ Not applicable for CDQP2 ø, ø, ø1, ø20, ø2, ø2 ø, ø1, ø20, ø2 ø2, ø0, ø0, ø, ø0, ø0 ø1, ø20 ø, ø, ø1 ø, ø, ø1, ø20, ø2 ø, ø, ø1, ø20 ø, ø, ø, ø1, ø20, ø2 D-A0V (Without indicator light) Auto swich model number Max. load current Contact protection Internal resistance D-AV/D-AV (With indicator light) D-AV Load voltag Max. load current and load current range Contact protection D-A0V IC /Relay/PLC AC 2V DC or less 0mA AC V DC or less 0mA AC 0V DC or less 20mA None 1Ω or less (Including m lead wire) 2V DC to 0mA Relay/PLC MXP MTS CXT MK MK2 RSQ CEP CY1R 0V AC to 20mA None 2.V or less ON: When red light emitting diode ø, ø, ø1 ø20, ø2, ø2, ø0 ø, ø1, ø20, ø2, ø2, ø0 ø, ø1 ø2, ø0, ø0, ø ø, ø2, ø0, ø0 ø, ø20 ø, ø, ø1, ø20 D-AV IC to V DC 20mA 0.V or less Lead wire D-A0V/D-AV Oilproof vinyl heavy insulation cable, ø2., 0.1mm 2 X 2cores (Brown, Blue), 0.m D-AV Oilproof vinyl heavy insulation cable, ø2., 0.1mm 2 X cores (Brown, Black, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Caution Precautions qfix the switch with appropriate screw installed on the switch body. If using other screws, switch may be damaged. RB J D -X 20- Technical Data Actuator series CDU CDQS CDQ2 MY1 MXU MXW MXF MXS Actuator series MXQ MXP MTS CXT MK MK2 RSQ CEP CY1R Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)..-20

21 Reed Switch/Direct Mounting D-0/D- Lead wire: Parallel cord Applicable Actuator CDJP- D CDU ø, ø, ø1 ø, ø, ø1, ø20, ø2, ø2 D-0 (Without indicator light) D-0 Relay/IC /PLC AC V DC AC V DC AC 2V DC D-0 (±) ± Contact protective box ( ) CD-P Black line CD-P (±) to ( ) ± Internal resistance D- (With indicator light) D- Relay/PLC 2V DC range to 0mA 2.V ON: When red light emitting diode Lead wire Vinyl parallel cable, 0.2mm 2, 2 cores, 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-0 Max. load current 0mA 1Ω or less (Including m lead wire) D- Zener diode Resistance LED Contact protective box CD-P Choke coil (+) (+) Zener diode to ( ) Black line ( ) D- Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box CDJP- D. Without shield plate. CDU With shield plate Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

22 Reed Switch/Direct Mounting D-0A/D-A Lead wire: Heavy insulation cable Applicable Actuator CDJP- D CDU ø, ø, ø1 ø, ø, ø1, ø20, ø2, ø2 D-0A (Without indicator light) D-0A Relay/IC /PLC AC V DC AC V DC AC 2V DC AC 0V DC D-0A D-A LED Zener diode Resistance Contact protection box CD-P CD-P Brown (Red) Blue (Black) Contact protection box CD-P CD-P (±) to ( ) ± (+) to ( ) Max. load current Internal resistance D-A (With indicator light) 0mA 20mA 1Ω or less (Including m lead wire) D-A Relay/PLC range 2V DC to 0mA 0V AC to 20mA 2.V ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, 0.2mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-0A D-A RB J D -X 20- Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. ein the case the load voltage is 0V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box. Technical Data CDJP- D. Without shield plate. CDU With shield plate Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

23 Reed Switch/Direct Mounting D-Z/D-Z/D-Z0 Applicable Actuator MGQ, MVGQ, MGP ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 CXS ø, ø, ø1, ø20, ø2, ø2 RSH ø20, ø2, ø0, ø, ø0 MY1B ø2, ø2, ø0, ø0, ø, ø0, ø0 MY1M, MY1C, CY1R ø2, ø2, ø0, ø0, ø MY1H, ML2B ø2, ø2, ø0 MGF ø0, ø, ø0 CY1H ø, ø1, ø20, ø2, ø2 D-Z (With indicator light) Auto swich model number Max. load current and load current range Contact protection D-Z (Without indicator light) D-Z D-Z Relay/PLC IC 2V DC to 0mA 0V AC to 20mA None to V DC 20mA 2.V (up to 20mA)/ V (up to 0mA) 0.V ON: When red light emitting diode D-Z0 Relay/PLC/IC D-Z D-Z LED Contact Resistance protection box Zener diode CD-P CD-P LED Resistance Load Reverse flow prevent diode (+) ( ) (+) to ( ) Max. load current Contact protection Internal resistance 0mA 0mA None 1Ω or less (Including m lead wire) 20mA Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-Z AC 2V DC or less D-Z, Z0 AC V DC or less AC 0V DC or less D-Z0.-2 Contact protection box CD-P CD-P (±) to ( ) Note) qin the case operation load is an inductive load. win the case the wiring length to > m. ein the case the load voltage is 0V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to the p..- for the details of contact protection box. ± MGQ, MVGQ CXS MGP RSH MY1B MY1M, MY1C MY1H, ML2B MGF CY1H CY1R Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

24 Reed Switch/Direct Mounting D-EA/D-EA/D-E0A Applicable Actuator CDBX ML1 ø ø2, ø2, ø0 D-E A (With indicator light) Auto swich model number Max. load current and load current range Contact protection D-E0A (Without indicator light) D-EA D-EA Relay/PLC IC 2V DC to 0mA 0V AC to 20mA None to V DC 20mA 2.V 0.V ON: When red light emitting diode D-E0A Relay/PLC/IC AC 2V DC or less AC V DC AC 0V DC Max. load current Contact protection Internal resistance 0mA 0mA 20mA None 1Ω or less (Including m lead wire) Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-EA LED D-EA D-E0A Resistance Zener diode LED Resistance Reverse flow prevent diode Load Contact protection box CD-P CD-P (+) (DC) ( ) (+) to ( ) RB J D -X 20- Technical Data Contact protection box CD-P CD-P (±) to ( ) Note) qin the case operation load is an inductive load. win the case the wiring length to load is > m. ein the case the load voltage is 0V AC. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to p..- for the details of contact protection box. ± CDBX ML1 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%).-2

25 2 Colour Indication Style Reed Switch/Band Mounting D-BW The suitable operating point can be indicated with a green light. (Red Green Red) Applicable Actuator CDM2, CDBM2, CDVM, CDVM, CDLM2 CDG1, MGG CDLG1 CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CE2, CNA MGC MLGC, RHC, REC ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-BW (With indicator light) range Contact protection D-BW Relay/PLC 2V DC to 0mA Built-in V Operating point: Red light emitting diode Suitable operating point: Green light emitting diode D-BW Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to the p..- for lead wire length. Choke coil Zener diode (+) Switch main LED ( ) /Operation CDM2, CDBM2, CDVM, CDVM, CDLM2 CDG1 CDLG1 CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CNA, CE2 MGG, MGC MLGC, RHC, REC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

26 2 Colour Indication Style Reed Switch/Rail Mounting D-AW The suitable operating point can be indicated with a green light. (Red Green Red) Applicable Actuator CDJ2, CDVJ CDLJ2 CDQ2 ø, ø1 ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø RSDQ MDU CE1 MK, MK2 CXT ø20, ø2, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 D-AW (With indicator light) range Contact protection D-AW Relay/PLC 2V DC to 0mA None V Operating point: Red light emitting diode Suitable operating point: Green light emitting diode D-AW Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on the p..-. Note 2) Refer to the p..- for lead wire length. Switch main LED Reverse flow prevent diode /Operation (+) ( ) RB J D -X 20- Technical Data Note) qin the case operation load is an inductive load. win the case the wiring length to load is more than m. Be sure to use the auto switch with the contact protection box in any case mentioned above. Refer to the p..- for the details of contact protection box. CDJ2, CDVJ CDLJ2 CDQ2 RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ±0%).-2

27 2 Colour Indication Style Reed Switch/Tie-rod Mounting D-AW The suitable operating point can be indicated with a green light. (Red Green Red) D-AW Applicable Actuator MDB, MDBB D-AW (With indicator light) CDA1, CDBA1, CDV, CDVS, CDLA, CE2, CNA CDL1 CDS1 range Contact protection ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø2, ø0, ø0, ø, ø0, ø0 D-AW Relay/PLC 2V DC to 0mA Built-in V Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Choke coil Zener diode (+) Switch main LED ( ) /Operation CDA1, CDBA1, CDV, CDVS, CDLA, CE2, CNA CDL CDS1 1 MDB, MDBB Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

28 Solid State Switch General Purpose Auto Switch, 2 Colour Indication Style, 2 Colour Indication Style with Diagnostic Output, Water Resistant 2 Colour Indication Style, With Timer, Strong Magnetic Field Resistant Style Mounting Style Function Electrical entry Auto switch model No. Page method General purpose auto switch Band Rail Tie-rod Direct Connector Terminal conduit Connector Terminal conduit D-HA1/HA2/HB D-G/GP/K D-HC D-G/K D-GA/KA D-F/FP/J D-FNV/FPV/FBV D-JC D-F/FP/J1/J D-GC/KC D-MN/MP/MB D-MNV/MPV/MBV D-YA/YB/YP D-YA/YB/YPV D-MN/MP/MB Solid state switch 2 Colour indication style 2 Colour indication style with diagnostic output Band Rail Tie-rod Direct Band Rail Tie-rod D-HNW/HPW/HBW D-GW/GPW/KW D-FW/FPW/JW D-FNWV/FBWV D-FW/FPW/JW D-MNW/MPW/MBW D-YNW/YPW/YBW D-YNWV/YPWV/YBWV D-FNW/FPW/FBW D-FNWV/FPWV/FBWV D-HLF(Latching style) D-HNF D-GF D-FLF(Latching style) D-FF D-FF D-FLF(Latching style) RB J D -X 20- Technical Data Water resistant 2 colour indication style Band Rail Tie-rod D-HBAL D-GBAL D-FBAL D-FBAL Direct D-YBAL.- D-FBAL.- With timer Band Rail Tie-rod Direct D-GNTL D-FNTL D-FNTL D-MNTL/MPTL Magnetic field resistance Rail D-PDWL.-.-2

29 Solid State Switch/Band Mounting D-HA1/D-HA2/D-HB Applicable Actuator CDJ2 CDVJ, CDVJ CDLJ2 CDM2, CDBM2, CDVM,CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-HA1 D-H (With indicator light) D-HA1 Output Current consumption NPN 2V DC or less 0mA or less 1.V 0.V at ma of load current wire D-HA2 PNP IC /Relay/PLC //2V DC (. to 2V DC) ma or less 0µ A at 2V DC 0mA or less 0.V or less ON: When red light emitting diode D-HB 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V or less 0.mA at 2V DC Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-HA2 D-HB.-2 CDJ2 CDVJ, CDVJ CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGG, MGC RHC, MLGC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

30 Solid State Switch/Band Mounting D-G/D-GP/D-K Applicable Actuator CDG1, MGG CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE2 ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 ø0, ø0, ø, ø0, ø0 D-G D-GP D-G /D-K (With indicator light) D-G Output Current consumption NPN wire 2V DC or less 0mA or less 0mA or less 1.V or less 0.V or less at ma 0.V or less of load current 0µ A at 2V DC D-GP PNP IC /Relay/PLC //2V DC (. to 2V DC) ma or less ON: When red light emitting diode D-K 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V or less 0.mA at 2V DC Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. RB J D -X 20- Technical Data D-K (+) ( ) CDG1, MGG CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

31 Solid State Switch/Band Mounting D-HC Connector Applicable Actuator CDJ2 CDVJ, CDVJ CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 Caution Precautions qconfirm that the connector is appropriately tightened. If tightened insufficiently, the water resistant performance will deteriorate. wrefer to p..- for the details. D-HC (+) D-HC (With indicator light) Output Current consumption D-HC 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0.mA at 2V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. ( ) CJ2 CDVJ, CDVJ CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDM2, CDLG1, REC CDG1, MGG RSDQ MGC RHC, MLGC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

32 Solid State Switch/Band Mounting D-G/D-K Terminal conduit Caution Precautions quse cable whose O. D. is within the size in the figure to maintain water resistant performance. wafter wiring, confirm that tightening gland and all screws are tightened. Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 RHC D-G/D-K (With indicator light) D-G ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0 D-K Output Current consumption wire NPN IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA 0.V or less at ma of load current V 0µ A or less at 2V DC 0.mA or less at 2V DC ON: When red light emitting diode Note) Refer to common specifications on p..- D-G RB J 1st terminal 2nd terminal D -X 20- rd terminal D-K Technical Data (+) 1st terminal ( ) 2nd terminal CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 RHC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

33 Solid State Switch/Band Mounting D-GA/D-KA Terminal conduit Applicable Actuator CDM2, CDBM2, CDLM2 ø20, ø2, ø2, ø0 Caution Precautions quse cable whose O. D. is within the size in the figure to maintain water resistant performance. wafter wiring, confirm that tightening gland and all screws are tightened. D-GA D-GA/D-KA Output Current consumption D-GA wire NPN IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V or less 0.V or less at ma of load current D-KA 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V or less 0µ A or less at 2V DC 0.mA or less at 2V DC ON: When red light emitting diode Note) Refer to common specifications on p..-. 1st terminal 2nd terminal rd terminal D-KA (+) 1st terminal ( ) 2nd terminal CDM2, CDBM2, CDLM2 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

34 Solid State Switch/Rail Mounting D-F/D-FP/D-J D-F D-FP Applicable Actuator CDJ2, CDVJ, CDVJ CDQ2 CD XW CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT D-F /D-J (With indicator light) D-F Output Current consumption ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Plate mounted(p), ø, ø1, ø20, ø2, ø2, Housing mounted(b), ø1, ø20, ø2, ø2 ø, ø, ø1, ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 D-FP wire NPN PNP IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V or less 0.V or less at ma of load current 0µ A at 2V DC 0mA or less 0.V or less ON: When red light emitting diode D-J 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V or less 0.mA at 2V DC Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. RB J D -X 20- D-J (+) ( ) CDJ2, CDVJ, CDVJ CDQ2 B CD XW P CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ±0%) Technical Data.-

35 Solid State Switch/Rail Mounting D-FNV/D-FPV/D-FBV Electrical entry: Perpendicular Applicable Actuator CDJ2, CDVJ, CDVJ ø, ø1 CDQ2 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø CD XW Plate mounted(p), ø, ø1, ø20, ø2, ø2, Housing mounted(b), ø1, ø20, ø2, ø2 CDY1S, CY1L ø, ø, ø1, ø20, ø2, ø2, ø0 RSDQ ø20, ø2, ø0, ø0 MDU ø2, ø2, ø0, ø0, ø CE1 ø, ø20, ø2, ø0, ø0, ø MK, MK2 ø20, ø2, ø2, ø0, ø0, ø CXT ø2, ø0 D-FNV D-F V (With indicator light) D-FNV Output Current consumption NPN 2V DC 0mA 1.V or less 0.V or less at ma of load current wire D-FPV PNP IC /Relay/PLC //2V DC (. to 2V DC) ma 0µ A at 2V DC 0mA 0.V or less ON: When red light emitting diode D-FBV 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V or less 0.mA at 2V DC Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-FPV (+) D-FBV.- ( ) CDJ2, CDVJ, CDVJ CDQ2 B CD XW P CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

36 Solid State Switch/Rail Mounting D-JC Caution Precautions D-JC Connector qconfirm that the connector is appropriately tightened. If tightened insufficiently, the waterproof performance will deteriorate. wrefer to p..- for the details. (+) ( ) Applicable Actuator CDJ2, CDVJ, CDVJ CDQ2 CD XW CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT D-JC ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Plate mounted ø, ø1, ø20, ø2, ø2 Housing munted ø1, ø20, ø2, ø2 ø, ø, ø1, ø20, ø2, ø2, ø0 ø20, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 D-JC Output 2V DC Relay/PLC Current consumption 2V DC ( to 2V DC) to 0mA V 0.mA at 2V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. RB J D -X 20- Technical Data CDJ2, CDVJ, CDVJ CDQ2 B CD XW P CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

37 Solid State Switch/Tie-rod Mounting D-F /D-J Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø0, ø0, ø, ø0, ø0 ø2, ø0, ø, ø0, ø0 D-F D-FP D-F /D-J D-F D-FP D-J D-J1 wire Output NPN PNP Current consumption IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 2V DC Relay/PLC 2V DC ( to 2V DC) AC Relay/PLC 0 to 20V AC 0mA 1.V or less 0mA to 0mA to 0mA 0.V or less at ma of load current 0.V or less V or less 1V or less 0µA at 2V DC 0.mA at 2V DC 1mA at 0 V DC 1.mA at 200V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on the p..-. Note 2) Refer to the p..- for lead wire length. D-J1 differs in the shape, most sensitive position and operation range from other switches. Contact SMC for the details. D-J (+) ( ) D-J1.- (+) ( ) CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

38 Solid State Switch/Tie-rod Mounting D-GC/D-KC Terminal conduit Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1, CNA CE2 ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0 Caution Precautions quse cable whose O. D. is within the size in the figure to maintain water resistant performance. wafter wiring, confirm that tightening gland and all screws are tightened. D-GC/D-KC D-GC D-KC wire Output NPN IC /Relay/PLC 2V DC Relay/PLC //2V DC (. to 2V DC) Current consumption ma 2V DC 2V DC ( to 2V DC) 0mA to 0mA 1.V ( 0.V at ma of load current) V 0µ A or less at 2V DC 0.mA or less at 2V DC ON: When red light emitting diode Note 1) Refer to common specifications on p..-. D-GC 1st terminal 2nd terminal RB J D-KC rd terminal (+) 1st terminal D -X 20- ( ) 2nd terminal CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CNA CE2 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%) Technical Data Auto switch part number D-GC-, D-KC- D-GC-, D-KC- D-GC-, D-KC- D-GC-, D-KC- D-GC-, D-KC C 2 2 HW 1 1 H 0. H' T T'..... Z M X 1 M X 20 M X 2.-

39 Solid State Switches: Direct Mounting Type D-MN(V), D-MP(V), D-MB(V) 2-wire load current is reduced (2. to 0 ma). Lead-free Use of lead wire compliant with UL standards (style 2) 1. times the flexibility compared with conventional products (comparison with other SMC products) Conventional D-M Caution Operating Precautions When the cable sheath is stripped, confirm the stripping direction. The insulator may be split or damaged depending on the direction. Auto Switch D-MN, D-MNV Switch main DC (+) Brown Black Auto Switch PLC: Programable Logic Controller D-M (with indicator light) Switch model D-MN D-MP D-MB type -wire 2-wire Output type NPN PNP Applicable load Power supply voltage Current consumption IC, Relay, PLC,, 2 VDC (. to 2 V) ma or less 2 VDC relay, PLC 2 VDC or less 0 ma or less 0. V or less 2 VDC ( to 2 VDC) 2. to 0 ma V or less Leakage current 0 µ A or less at 2 VDC Red LED lights when ON 0. ma or less Lead wire Oil proof heavy duty vinyl cord: 2..2 ellipse D-MB 0.1 mm 2 2 cores D-MN, D-MP 0.1 mm 2 cores Note 1) Refer to page 1 for solid state auto switch common specifications and lead wire length. Weight Auto switch model Lead wire length m D-M D-MB, N, P D-MN(V) 1 Mounting screw M2. x L Slotted set screw D-MN, P (-wire) - D-MB (2-wire).2 Refer to for details of products compatible with overseas standards. D-MP(V) 1 D-MB(V) 2. Unit: g D-MP, D-MPV DC ( ) Blue D-M V Most sensitive position 22 DC (+) Brown Switch main Black DC ( ) Blue D-MB, D-MBV (+) Brown Mounting screw Slotted set screw Switch main Most sensitive position ( ) Blue.-

40 Solid State Switch/Direct Mounting D-Y A /D-Y A /D-YP(V) B B D-YA, D-YA D-YP(V) Applicable Actuator MGQ, MVGQ, MGP CXS MY1B MY1C, MY1M, CY1R MY1H, ML2B MGF CY1H RSH D-YA, D-YP, D-YB ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø, ø, ø1, ø20, ø2, ø2 ø2, ø2, ø0, ø0, ø, ø0, ø0 ø2, ø2, ø0, ø0, ø ø2, ø2, ø0 ø0, ø, ø0 ø, ø1, ø20, ø2, ø2 ø20, ø2, ø0, ø, ø0 D-Y/D-Y/D-YP/D-YPV (With indicator light) D-YA D-YA D-YP D-YPV D-YB D-YB Electrical entry Output In-line Perpendicular wire NPN In-line Perpendicular PNP In-line Perpendicular Current consumption IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 2V DC Relay/PLC 2V DC ( to 2V DC) 0mA 1.V or less 0mA or less to 0mA 0.V or less at ma 0.V or less V or less of load current 0µ A or less at 2V DC 0.mA or less at 2V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.1mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-YA, D-YPV, D-YB RB J D -X 20- Technical Data D-YB, D-YB (+) ( ) MGQ, MVGQ.. CXS... MGP.... MY1B MY1C, MY1M MY1H RSH. CY1R CY1H ML2B MGF Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

41 Solid State Switch/Direct Mounting D-MN/D-MP/D-MB Applicable Actuator MYC MYH ML1 ø2, ø2, ø0 ø2, ø2, ø0 ø2, ø2, ø0 D-MN D-M (With indicator light) D-MN Output Current consumption NPN wire 2V DC 0mA 0mA 1.V or less 0.V or less at ma 0.V or less of load current 0µ A at 2V DC D-MP PNP IC /Relay/PLC //2V DC (. to 2V DC) ma ON: When red light emitting diode D-MB 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V or less 0.mA at 2V DC Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-MP D-MB (+) ( ) MYC MYH ML1 2 2 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%) 0.-1

42 2 Colour Indication Style Solid State Switch/Band Mounting D-HNW/D-HPW/D-HBW The suitable operating point can be indicated with a green light. (Red Green Red) Applicable Actuator CDJ2 CDVJ, CDVJ CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-HNW D-HPW D-H W(With indicator light) Output Current consumption D-HNW D-HPW D-HBW wire NPN PNP IC /Relay/PLC 2V DC Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V or less 0mA 2V DC ( to 2V DC) to 0mA 0.V or less at ma of load current 0.V or less V or less 0µ A or less at 2V DC 0.mA or less at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. RB J D -X 20- D-HBW (+) Technical Data /Operation ( ) CDJ2 CDVJ, CDVJ CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGG, MGC RHC, MLGC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

43 2 Colour Indication Style Solid State Switch/Band Mounting D-GW/D-GPW/D-KW The suitable operating point can be indicated with a green light. (Red Green Red) Applicable Actuator CDG1, MGG CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE2 ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 ø0, ø0, ø, ø0, ø0 D-GW D-G /D-K (With indicator light) D-GW Output Current consumption D-GPW D-KW wire NPN PNP IC /Relay/PLC 2V DC Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V or less 0mA or less 2V DC ( to 2V DC) to 0mA 0.V or less at ma of load current 0.V or less V or less 0µ A or less at 2V DC 0.mA or less at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-GPW D-KW (+) ( ) /Operation CDG1, MGG CDA1, CDBA1, CDV, CDVS, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

44 2 Colour Indication Style Solid State Switch/Rail Mounting D-FW/D-FPW/D-JW The suitable operating point can be indicated with a green light. (Red Green Red) Applicable Actuator CDJ2, CDVJ, ø, ø1 CDQ2 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø CD XW Plate mounted(p), ø, ø1, ø20, ø2, ø2, Housing mounted(b), ø1, ø20, ø2, ø2 CDY1S, CY1L ø, ø, ø1, ø20, ø2, ø2, ø0 RSDQ ø20, ø2, ø2, ø0, ø0 MDU ø2, ø2, ø0, ø0, ø CE1 ø, ø20, ø2, ø0, ø0, ø MK, MK2 ø20, ø2, ø2, ø0, ø0, ø CXT ø2, ø0 D-FW D-FPW D-JW (+) ( ) D-F W/D-JW Output Current consumption D-FW NPN wire IC /Relay/PLC //2V DC (. to 2V DC) 2V DC 0mA 1.V ( 0.V at ma load current) ma D-FPW PNP 0mA 0.V D-JW 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0µA at 2V DC 0.mA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. RB J D -X 20- Technical Data /Operation CDJ2, CDVJ, CDQ2 B CD XW P CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

45 2 Colour Indication Style Solid State Switch/Rail Mounting D-FNWV/D-FBWV Electrical entry: Perpendicular The suitable operating point can be indicated with a green light. (Red Green Red) D-FNWV Applicable Actuator CDJ2, CDVJ, CDQ2 CD XW CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT D-F WV (With indicator light) D-FNWV Output Current consumption ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Plate mounted(p), ø, ø1, ø20, ø2, ø2, Housing mounted(b), ø1, ø20, ø2, ø2 wire NPN IC /Relay/PLC //2V DC (. to 2V DC) ma ø, ø, ø1, ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 D-FBWV 2V DC Relay/PLC 2V DC 2V DC ( to 2V DC) 0mA to 0mA 1.V ( 0.V at ma load current) V 0µA or less at 2V DC 0.mA or less at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-FBWV (+) /Operation.- ( ) CDJ2, CDVJ, CDQ2 B CD XW P CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

46 2 Colour Indication Style Solid State Switch/Tie-rod Mounting D-FW/D-FPW/D-JW The suitable operating point can be indicated with a green light. (Red Green Red) Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø0, ø0, ø, ø0, ø0 ø2, ø0, ø, ø0, ø0 D-FW D-FPW D-JW (+) ( ) D-F W/D-JW (With indicator light) Output Current consumption D-FW NPN wire D-FPW PNP IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V ( 0.V at ma load current) 0mA 0.V D-JW 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0µA at 2V DC 0.mA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. RB J D -X 20- (+) Technical Data ( ) /Operation CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

47 2 Colour Indication Style Solid State Switch/Direct Mounting D-MNW/D-MPW/D-MBW The suitable operating point can be indicated with a green light. (Red Green Red) Applicable Actuator MYC MYH ML1 ø2, ø2, ø0 ø2, ø2, ø0 ø2, ø2, ø0 D-MNW D-M W (With indicator light) D-MNW D-MPW D-MBW wire Output NPN PNP Current consumption IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 2V DC Relay/PLC 2V DC ( to 2V DC) 0mA 0mA to 0mA 1.V ( 0.V at ma load current) 0.V V 0µA at 2V DC Operating point: Red light emitting diode 1mA at 2V DC Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to the p..- for lead wire length. D-MPW D-MBW (+) /Operation ( ) MYC MYH ML1 2 2 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%) 0.-

48 2 Colour Indication Style Solid State Switch/Direct Mounting D-YNW(V)/D-YPW(V)/D-YBW(V) D-YNW(V) D-YPW(V) The suitable operating point can be indicated with a green light. (Red Green Red) D-YBW(V) (+) Applicable Actuator CXS MGQ, MVGQ MGP MY1B MY1C MY1H MY1M RSH D-Y W/D-Y WV (With indicator light) D-YNW D-YNWV D-YPW ø, ø, ø1, ø20, ø2, ø2 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø2, ø2, ø0, ø0, ø, ø0, ø0 ø2, ø2, ø0, ø0, ø ø2, ø2, ø0 ø2, ø2, ø0, ø0, ø ø20, ø2, ø0, ø, ø0 D-YPWV D-YBW D-YBWV Electrical entry In-line Perpendicular In-line Perpendicular In-line Perpendicular wire Output NPN PNP Current consumption IC /Relay/PLC //2V DC (. to 2V DC) ma or less 2V DC or less 2V DC Relay/PLC 2V DC ( to 2V DC) 0mA or less 0mA or less to 0mA 1.V ( 0.V at ma load current) 0.V V 0µA or less at 2V DC 0.mA or less at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.1mm 2, cores (Brown, Black, Blue), 2 cores (Brown, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-Y W D-Y WV RB J D -X 20- Technical Data /Operation ( ) MGQ, MVGQ CXS MGP MY1B MY1C, MY1M MY1H RSH CY1R CY1H ML2B MGF Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

49 2 Colour Indication Style with Diagnostic Output Solid State Switch/Band Mounting D-HLF (Latching Style) The output signal can be detected in an unsteady detecting area. Applicable Actuator CDJ2 CDVJ, CDLJ2 CDM2, CDBM2, CDVM,, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-HLF (With indicator light) Output Diagnostic output Current consumption D-HLF wire NPN Latching operation 2V DC Relay/PLC 2V DC (20 to 2V DC) 20mA 2V DC 0mA 0.V 0µ A at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Orange colour indicator lights on when diagnostic output is ON. (Normal output) (Diagnostic output) Orange(Blue) Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Orange, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Diagnostic Output Operation The diagnostic signal is output when detecting position remains within unsteady area (where indicator light is Red.) for more than 0. sec. This signal keeps outputting even after normal output goes to OFF. The diagnostic output becomes OFF when detecting position remains within the most suitable operating range (where indicator light is Green.) for more than 0. sec. CDJ2 CDVJ, CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

50 2 Colour Indication Style with Diagnostic Output Solid State Switch/Band Mounting D-HNF The output signal can be detected in an unsteady detecting area. Applicable Actuator CDJ2 CDVJ, CDLJ2 CDM2, CDBM, CDVM,, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-HNF (With indicator light) Output Diagnostic output Current consumption D-HNF wire NPN Normal operation IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V ( 0.V at ma) 0µ A at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode (Normal output) (Diagnostic output) Orange(Yellow) Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Orange, Blue), 0.m Note 1) Refer to common specifications on tp..-. Note 2) Refer to p..- for lead wire length. Diagnostic Output Operation The diagnostic output is detected when detecting position remains at unsteady area only, not available at the most suitable operating area, thus diagnostic signal can be output only when the detecting position is far from the suitable position for normal operation. RB J D -X 20- Technical Data CDJ2 CDVJ, CDLJ2 CDM2, CDBM2, CDVM, CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%).-0

51 2 Colour Indication Style with Diagnostic Output Solid State Switch/Band Mounting D-GF The output signal can be detected in an unsteady detecting area. Applicable Actuator CDG1, MGG CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1, CNA MGC RHC, MLGC CE2 Can not be used for lube type. ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 ø0, ø0, ø, ø0, ø0 (Normal output) (Diagnostic output) Orange(Yellow) D-GF (With indicator light) Output Diagnostic output Current consumption D-GF wire NPN IC /Relay/PLC Normal operation ma 2V DC 0mA 1.V ( 0.V at ma) 0µA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.2mm 2, cores (Brown, Black, Orange, Blue), 0.m Note 1) Refer to common specifications on the p..-. Note 2) Refer to the p..- for lead wire length. Diagnostic Output Operation The diagnostic output is detected when detecting position remains at unsteady area only, not available at the most suitable operating area, that is to say, diagnostic signal can be output only when the detecting position is far from the suitable position for normal operation CDG1, MGG CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1, CNA MGC RHC, MLGC CE Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

52 2 Colour Indication Style with Diagnostic Output Solid State Switch/Rail Mounting D-FLF (Latching Style) The output signal can be detected in an unsteady detecting area. (Normal output) (Diagnostic output) Orange(Blue) Applicable Actuator CDJ2, CDVJ, CDQ2 CD XW CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT D-FLF (With indicator light) Output Diagnostic output Current consumption ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Housing mounted(b), ø1, ø20, ø2, ø2 ø, ø, ø1, ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø ø2, ø0 D-FLF wire NPN Latching operation 2V DC Relay/PLC 2V DC (20 to 2V DC) 20mA 2V DC 0mA 0.V 0µ A at 2V DC Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown,Black, Orange, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Diagnostic Output Operation The diagnostic signal is output when detecting position remains within unsteady area (where indicator light is Red.) for more than 0. sec. This signal keeps outputting even after normal output goes to OFF. The diagnostic output becomes OFF when detecting position remains within the most suitable operating range (where indicator light is Green.) for more than 0. sec. Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Orange colour indicator lights on when diagnostic output is ON. RB J D -X 20- Technical Data Actuator series CDJ2, CDVJ, CDVJ CDQ2 CD XW B CDY1S, CY1L RSDQ MDU CXT CE1 MK, MK Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

53 2 Colour Indication Style with Diagnostic Output Solid State Switch/Rail Mounting D-FF The output signal can be detected in an unsteady detecting area. (Normal output) (Diagnostic output) Orange(Yellow) Applicable Actuator CDJ2, CDVJ, CDQ2 CD XW CDY1S, CY1L RSDQ MDU CXT CE1 MK, MK2 D-FF (With indicator light) Output Diagnostic output Current consumption ø, ø1 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø Plate mounted(p), ø, ø1, ø20, ø2, ø2 Housing mounted, ø1, ø20, ø2, ø2 ø, ø, ø1, ø20, ø2, ø2, ø0 ø20, ø2, ø0, ø0 ø2, ø2, ø0, ø0, ø ø2, ø0 ø, ø20, ø2, ø0, ø0, ø ø20, ø2, ø2, ø0, ø0, ø D-FF wire NPN Normal operation IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V (0.V at ma) 0µ A at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Orange, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Diagnostic Output Operation The diagnostic output is detected when detecting position remains at unsteady area only, not available at the most suitable operating area, that is to say, diagnostic signal can be output only when the detecting position is far from the suitable position for normal operation. Actuator series CDJ2, CDVJ, CDVJ CDQ2 B CD XW P CDY1S, CY1L. RSDQ MDU CXT CE1 MK, MK Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

54 2 Colour Indication Style with Diagnostic Output Solid State Switch/Tie-rod Mounting D-FF The output signal can be detected in an unsteady detecting area. Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø0, ø0, ø, ø0, ø0 ø2, ø0, ø0, ø, ø0, ø0 (Normal output) (Diagnostic output) Orange(Yellow) D-FF Output Diagnostic output Current consumption D-FF wire NPN Normal operation IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V ( 0.V at ma) 0µ A at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.2mm 2, cores (Brown, Black, Orange, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Diagnostic Output Operation The diagnostic output is detected when detecting position remains at unsteady area only, not available at the most suitable operating area, that is to say, diagnostic signal can be output only when the detecting position is far from the suitable position for normal operation. RB J D -X 20- Technical Data CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

55 Water Resistant 2 Colour Inudication Style Solid State Switch/Band Mounting D-HBAL Water (coolant) resistant performance Caution Precautions Consult SMC if using coolant liquid other than water based solution. (+) Applicable Actuator CDJ2 CDVJ, CDLJ2 CDM2, CDBM2, CDVM,, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC MLGC D-HBAL (With indicator light) Output Current consumption ø, ø, ø1 ø, ø1 ø1 ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 D-HBAL 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0.mA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, 2 cores (Brown, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. ( ) /Operation CDJ2 CDVJ, CDLJ2 CDM2, CDBM2, CDVM, CDLM2, CDLG1, REC CDG1, MGG RSDG MGC RHC, MLGC Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

56 Water Resistant 2 Colour Indication Style Solid State Switch/Band Mounting D-GBAL Water (coolant) resistant performance Applicable Actuator CDG1, MGG CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE2 Can not be used for lube type. ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 ø0, ø0, ø, ø0, ø0 Caution Precautions Consult SMC if using coolant liquid other than water based solution. D-GBAL (With indicator light) Output Current consumption D-GBAL 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0.mA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. (+) ( ) RB J D -X /Operation 20- Technical Data CDG1, MGG CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE Note) Average value at normal temperature including hysteresis.(tolerance ±0%).-

57 Water Resistant 2 Colour Indication Style Solid State Switch/Rail Mounting D-FBAL Water (coolant) resistant performance Applicable Actuator CDJ2, CDVJ, ø, ø1 CDQ2 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø CD XW Plate mounted(p), ø, ø1, ø20, ø2, ø2, Husuing mounted(b), ø1, ø20, ø2, ø2 CDY1S, CY1L ø, ø, ø1, ø20, ø2, ø2, ø0 RSDQ ø20, ø2, ø2, ø0, ø0 MDU ø2, ø2, ø0, ø0, ø CE1 ø, ø20, ø2, ø0, ø0, ø MK, MK2 ø20, ø2, ø2, ø0, ø0, ø CXT ø2, ø0 Caution Precautions Consult SMC if using coolant liquid other than water based solution. D-FBAL (With indicator light) Output Current consumption Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-FBAL 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0.mA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode (+) ( ) /Operation.- CDJ2, CDVJ, CDQ2 B CD XW P CDY1S, CY1L RSDQ MDU CE1 MK, MK2 CXT Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

58 Water Resistant 2 Colour Indication Style Solid State Switch/Tie-rod Mounting D-FBAL Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø0, ø0, ø, ø0, ø0 ø2, ø0, ø, ø0, ø0 Caution Precautions Consult SMC if using coolant liquid other than water based solution. /Operation (+) ( ) D-FBAL (With indicator light) Output Current consumption D-FBAL 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0.mA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. Water (coolant) resistant performance RB J D -X 20- Technical Data CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

59 Solid State Switch with Timer/Band Mounting D-GNTL Timer Operation With built-in OFF-delay timer (200ms) Applicable Actuator CDM2, CDBM2, CDVM,, CDLM2, CDLG1 CDG1, MGG CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE2 D-GNTL (With indicator light) Output Output operation Operation time Off-delay time Current consumption Detection of immediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e. g. scanning. Ex.)Cylinder speed - 00 mm/sec. Sequencer response time sec. Detecting point despersion - Within 0mm ( = 00mm/sec. X 0.1 sec.) Take PLC response time into consideration when using. ø20, ø2, ø2, ø0 ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0 ø20, ø2, ø2, ø0, ø0 ø20, ø2, ø2, ø0 ø0, ø0, ø, ø0, ø0 D-GNTL wire NPN Off-delay 1ms 200±0ms IC /Relay/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 2V ( 0.V at ma) 0µ A at 2V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, cores (Brown, Black, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length..- CDM2, CDBM2, CDVM,, CDLM2, CDLG1 CDG1, MGG CDA1, CDBA1, CDV, CDVS1, CDLA, CDL1, CNA MGC RHC, MLGC, REC CE2 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

60 Solid State Switch with Timer/Rail Mounting D-FNTL With built-in OFF-delay timer (200ms) Applicable Actuator CDJ2, CDVJ, ø, ø1 CDQ2 ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0, ø, ø10, ø CD XW Plate mounted(p), ø, ø1, ø20, ø2, ø2, Housing mounted(b), ø1, ø20, ø2, ø2 CDY1S, CY1L ø, ø, ø1, ø20, ø2, ø2, ø0 RSDQ ø20, ø2, ø2, ø0, ø0 MDU ø2, ø2, ø0, ø0, ø CE1 ø, ø20, ø2, ø0, ø0, ø MK, MK2 ø20, ø2, ø2, ø0, ø0, ø CXT ø2, ø0 Timer Operation D-FNTL (With indicator light) Detection of immediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e. g. scanning. Ex.) Cylinder speed-00 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-within 0mm (=00mm/sec. X 0.1sec.) Take PLC response time into consideration when using. D-FNTL wire Output NPN Output operation Off-delay Operation time 1ms Off-delay time 200±0ms IC /Relay/PLC //2V DC (. to 2V DC) Current consumption ma 2V DC 0mA 1.V ( 0.V at ma) 0µ A at 2V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. RB J D -X 20- Technical Data CDJ2, CDVJ, CDQ2.... CD XW B.. P CDY1S, CY1L. RSDQ. MDU.... CE1... MK, MK2 CXT.. Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

61 Solid State Switch with Timer/Tie-rod Mounting D-FNTL Timer Operation With built-in OFF-delay timer (200ms) Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB Detection of immediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e. g. scanning. Ex.) Cylinder speed-00 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-within 0mm (=00mm/sec. X 0.1sec.) Take PLC response time into consideration when using. ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø0, ø0, ø, ø0, ø0 ø2, ø0, ø, ø0, ø0 D-FNTL (With indicator light) D-FNTL wire Output NPN Output operation Off-delay Operation time 1ms Off-delay time 200±0ms IC /Relay/PLC //2V DC (. to 2V DC) Current consumption ma 2V DC 0mA 1.V ( 0.V at ma) 0µ A at 2V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, cores (Brown, Black, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length..-1 CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

62 Solid State Switch with Timer/Direct Mounting D-MNTL/D-MPTL With built-in OFF-delay timer (200ms) Applicable Actuator MYC MYH ML1 ø2, ø2, ø0 ø2, ø2, ø0 ø2, ø2, ø0 D-M TL (With indicator light) D-MNTL Output Output operation Operation time Off-delay time Current consumption lnternal voltage drop Timer Operation Detection of immediate positioning for high-speed cylinder Detecting point dispersion occurs due to response time of PLC (sequencer); e. g. scanning. Ex.) Cylinder speed-00 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-within 0mm (=00 mm/sec. X 0.1sec.) Take PLC response time into consideration when using. D-MNTL D-MPTL wire NPN PNP Off-delay 1ms 200±0ms IC /Relay/PLC //2V DC (. to 2V DC) ma ma 2V DC 0mA 2V 0.V ( 0.V at ma load current) 0µ A or less at 2V DC ON: When red light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.2mm 2, cores (Brown, Black, Blue), m (Standard) Note 1) Refer to common specifications on the p..-. Note 2) Refer to the p..- for lead wire length. RB J D -X 20- Technical Data D-MPTL 2 2 MYC MYH ML1 Note) Average value at normal temperature including hysteresis. (Tolerance ±0%) 0.-2

63 Water Resistant 2 Colour Indication Style Solid State Switch/Direct Mounting D-YBAL Improved coolant-resistant performance Applicable Actuator CXS ø, ø, ø1, ø20, ø2, ø2 MGQ, MVGQ ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 MGP ø, ø1, ø20, ø2, ø2, ø0, ø0, ø, ø0, ø0 RSH ø20, ø2, ø0, ø, ø0 Caution Precautions Consult SMC if using coolant liquid other than water based solution. D-YBAL (With indicator light) D-YBAL 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V 0.mA at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø., 0.1mm 2, 2 cores (Brown, Blue), m (Standard) Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. (+) ( ) /Operation Actuator series CXS MGQ, MVGQ MGP RSH MGF Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

64 Strong Magnetic Field Resistant 2 Colours lndication Style Solid State Switch/Rail Mounting D-PDWL Possible to use in an environment where disturbance magnetic field is generated. Applicable Actuator CDQ2 CDA1 MK, MK2, MDU ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0 ø0, ø0, ø Caution Precautions Monophase current welding. Not applicable for DC inverter welding, arc welding nor capacitor welding. D-PDW (With indicator light) Operation time Lead wire Oilproof vinyl heavy insulation cable, ø, 0.mm 2, 2 cores (Brown, Blue), m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-PDWL (Non-polar) 2V DC Relay/PLC 2V DC (20 to 2V DC) to 0mA V 1mA at 2V DC 0ms Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Strong Magnetic Field Resistance It is possible to use switches next to welding conductor (gun cable) in case that A. C. welding current is 1,000A. Consult SMC if exceeding 1,000A. (±) Brown ( ) Blue ± RB J D -X /Operation 20- Technical Data Operation Range( l Dimension) CDQ2 CDA1 MDL MK, MK

65 2 Colour lndication Style with Diagnostic Output Solid State Switch/Tie-rod Mounting D-FLF (Latching Style) The output signal can be detected in an unsteady detecting area. Applicable Actuator CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB D-FLF (With indicator light) Output Diagnostic output Current consumption ø0, ø0, ø, ø0, ø0 ø0, ø0, ø, ø0, ø0, ø, ø10, ø ø, ø10, ø, ø10, ø200 ø0, ø0, ø, ø0, ø0 ø2, ø0, ø, ø0, ø0 D-FLF wire NPN Latching operation 2V DC Relay/PLC 2V DC ( to 2V DC) 20mA 2V DC 0mA 0.V 0µ A at 2V DC Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Orange colour indicator lights on when diagnostic output is ON. Diagnostic Output Operation (Latching Style) The diagnostic signal is output when detecting position remains within unsteady area (where indicator light is Red.) for more than 0. sec. This signal keeps outputting even after normal output goes to OFF. The diagnostic output becomes OFF when detecting position remains within the most suitable operating range (where indicator light is Green.) for more than 0. sec. Lead wire Oilproof vinyl heavy insulation cable, ø, 0.2mm 2, cores (Brown, Black, Orange, Blue), 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. (Normal output) Diagnosis (Diagnostic output) Orange(Blue) CDA1, CDBA1, CDV, CDVS1, CDLA, CNA CDL1 CDS1 CE2 MDB Note) Average value at normal temperature including hysteresis. (Tolerance ±0%)

66 2 Colour lndication Style Solid State Switch/Direct Mounting D-FNW(V)/D-FPW(V)/D-FBW(V) Applicable Actuator CDU ø, ø, ø1, ø20, ø2, ø2 CDQ2 ø2, ø0, ø0, ø, ø0, ø0 CDQS ø, ø1, ø20, ø2 MY1 ø1, ø20 MXW ø, ø, ø1, ø20, ø2 MXF ø, ø, ø1, ø20 MXU ø, ø, ø1 MXS/MXQ ø, ø, ø, ø1, ø20, ø2 MXP ø, ø, ø1 MTS ø20, ø2, ø2, ø0 MK ø, ø1 MK2 ø2, ø0, ø0, ø Not available for series CDQP2 D-FNW(V) D-FPW(V) D-FBW(V) /Operation (+) ( ) D-F W/D-F WV (With indicator light) Electrical entry Output Current consumption D-FNW In-line NPN D-FNWV Perpendicular wire D-FPW In-line IC /Relay IC/PLC //2V DC (. to 2V DC) ma 2V DC 0mA 1.V ( 0.V at ma or load current) 0µA at 2V DC PNP 0mA 0.V or less D-FPWV Perpendicular D-FBW In-line Operating point: Red light emitting diode Suitable operating point: Green light emitting diode D-FBWV Perpendicular 2V DC Relay/PLC 2V DC ( to 2V DC) to 0mA V or less 0.mA or less Lead wire Oilproof vinyl heavy insulation cable, ø2., cores (Brown, Black, Blue), 0.1mm 2, 2 cores (Brown, Blue), 0.1mm 2, 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. D-FNW/D-FPW/D-FBW CDU(Without shield plate) CDQ2 MY1B, MY1H MY1C, MY1M MXW MXF MXU MXS, MXQ CDQS MK MK2 MXP MTS Note) Average value at normal temperature including hysteresis. (Tolerance ±0%) D-FNWV/D-FPWV/D-FBWV RB J D -X 20- Technical Data

67 Water Resistant 2 Colour Indication Style Solid State Switch/Direct Mounting D-FBAL Water (coolant) resistant performance Applicable Actuator CDU CDQ2 CDQS MK MK2 Not available for series CDQP2 ø, ø, ø1, ø20, ø2, ø2 ø2, ø0, ø0, ø, ø0, ø0 ø, ø1, ø20, ø2 ø, ø1 ø2, ø0, ø0, ø Caution Precautions Consult SMC if using coolant liquid other than water based solution. D-FBAL (With indicator light) Output Current consumption D-FBAL 2V DC Relay/PLC 2V DC (20 to 2V DC) to 0mA V 1mA at 2V DC (+) Operating point: Red light emitting diode Suitable operating point: Green light emitting diode Lead wire Oilproof vinyl heavy insulation cable, ø2., 2 cores (Brown, Blue), 0.1mm 2, 0.m Note 1) Refer to common specifications on p..-. Note 2) Refer to p..- for lead wire length. (-) /Operation CDU(Without shield plate) CDQ2 CDQS MK MK Note) Average value at normal temperature including hysteresis. (Tolerance ±0%).-

68 Information q Plug-in Connector Assembly/How to Use DIN Terminal Plug-in Connector Assembly D-AC, D-A0C, D-JC D-CC, D-C0C, D-HC How to Use DIN Terminal/D-A/AA/AC Connection qloosen the set screw and pull out the connector from the pin plug. wbe sure to remove the set screw first and then insert a screw driver into a recessed groove under the terminal block to separate the terminal cover from the terminal block. efollow the procedures and connect wires securely to specified terminals. rin standard cases, crimp-style terminals are used to connect wires. Please select proper crimp-style terminals so that the wire can be properly connected to terminal fittings. Method of connection AC: Connect to terminal No.1 and No.2 DC: Connect (+) to No.1 terminal and ( ) to No.2 terminal. With the convex port of the connector, insert the connector into the auto switch into the sleeve. Screw the locking ring onto the switch. (Do not tighten with pliers.) How to change position of electrical entry After separating the terminal block from the terminal cover, change the position of the terminal cover to any desired direction ( directions at every 0 ) to change the position of electrical entry. Caution When taking in or out the connector pin to or from the pin plug, hold the connector as perpendicular as possible. Applicable cable (heavy insulation cable) Applicable to cable O. D. of ø. to ø.. Applicable crimp-style terminal 1.2Y-L, 1.2-.S, 1.2-M RB J D -X 20- Technical Data.-

69 Information w How to Mount and Move the Auto Switch Mounting Bracket Band mounting Caution qtighten the screw under the specified torque when mounting auto switch. wset the mounting band perpendicularly to cylinder tube. Correct mounting Wrong mounting <Applicable auto switch> D-B, D-B, D-B D-BW Solid state switch D-G, D-GP, D-K, D-GBAL D-GW, D-GPW, D-KW D-GF D-GNTL <Applicable auto switch> D-C, D-C, D-C0 D-CC, D-C0C Solid state switch D-HA1, D-HA2, D-HB, D-HBAL D-HC D-HNF, D-HLF D-HNW, D-HPW, D-HBW How to mount and move the auto switch How to mount and move the auto switch qput a mounting band on the cylinder tube and set it at the auto switch mounting position. wput the mounting section of the auto switch between the band mounting holes, then adjust the position of mounting holes of switch to those of mounting band. elightly thread the auto switch mounting screw through the mounting hole into the thread part of band fitting. rafter setting the whole body to the detecting position by sliding, tighten the mounting screw to secure the auto switch. (The tightening torque of M screw should be about 1 to 1.2Nm.) tmodification of the detection position should be made in the condition of e. Part No. of auto switch mounting bracket (including band and screw).- Cylinder series CDM2, CDBM2 CDVM,, CDLM2 CDG1, MGG MGC CDLG1 CDA1, CDBA1, CDV, CNA CDVS, CDLA, CDL1, CE2 RHC, MLGC, REC 20 BA2-020 BA -01 BA BA2-02 BA -02 BA BA2 BA BA -2 BA- 2 BA -0 BA -0 BA -0 BA-0 BA-0 BA- BA BA -0 BA - Mounting screw set (Stainless steel specification) Use the following mounting screw set (Set screw included.) according to the required operating conditions. (Mounting band is not included.) BBA: For D-B/B/G/K D-GBAL is mounted on the cylinder with the above stainless steel screw BBA before shipment or BBA is enclosed with D-GBAL when shipped without cylinder. qfor series CDJ2/Put a mounting bracket on the cylinder tube. For series CDM2/Put a mounting band on the cylinder tube and set it at the auto switch mounting position. wput the mounting part of auto switch in the interval of stationary fitting to fit the mounting hole to the hole of stationary fitting. escrew lightly the auto switch mounting screw through the mounting hole into the thread part of band fitting. rafter setting the whole body to the detecting position by sliding, tighten the mounting screw to secure the auto switch. (The tightening torque of M screw should be about 0. to 1Nm.) tmodification of the detection position should be made in the condition of e. Part No. of auto switch mounting bracket (including band and screw) Cylinder series CDJ2 CDVJ, CDLJ2 CDM2, CDBM2 CDVM,, CDLM2 CDG1, MGG CDLG1 MGC RHC, MLGC, REC RSDG BJ2-00 BJ2-0 BJ2-01 BM2-020 BMA2-020 BM2-02 BMA2-02 BM2-02 BM2-00 BMA2-02 BMA2-00 BMA2-00 BMA2-00 BMA2-00 BMA2-0 Mounting screw set (Stainless steel specification) Use the following mounting screw set according to the required operating conditions. (Mounting band is not included.) BBA: For D-C/C/H D-HBAL is mounted on the cylinder with the above stainless steel screw BBA before shipment or BBA is enclosed with D-HBAL when shipped without cylinder.

70 Information w How to Mount and Move the Auto Switch Mounting Bracket Band mounting <Applicable auto switch> D-A, D-A, D-A Solid state switch D-G, D-K <Applicable auto switch> D-AA, D-AA, D-AA Solid state switch D-GA, D-KA D-A, D-G/K type D-A type qloosen the auto switch mounting screws at both sides to pull down the hook. wput a mounting band on the cylinder tube and set it at the auto switch mounting position, and then hook the band. escrew lightly the auto switch mounting screw. rset the whole body to the detecting position by sliding, tighten the mounting screw to secure the auto switch. (The tightening torque should be about 2 to Nm.) tmodification of the detecting position should be made in the condition of e. qtighten completely the switch mounting screw on the switch body side. wput a mounting band on the cylinder tube and set it at the auto switch mounting position. Put the mounting section of auto switch between the interval of mounting band, then adjust the position of mounting holes of switch to those of mounting band. elightly thread the auto switch mounting screw through the mounting hole into the thread part of band fitting. rafter reconfirming the detecting position, tighten the mounting screw to secure the auto switch. (The tightening torque of M screw should be about 2 to Nm.) tmodification of the detecting position should be made in the condition of e. Part No. of auto switch mounting bracket (including band and screw) Cylinder series CDM2, CDBM2 CDLM2 20 BM BM 02 BM 02 0 BM 00 RB J D -X 20- Technical Data Part No. of auto switch mounting band Cylinder series CDA1, CDBA1, CDV CDVS, CDLA, CE2, CNA CDL1 CDS1 RHC BD1 BD1 BD1 BD1-01M -02M -02-0M BD1 BD1 BD1 BD1 BD1-0M -0M -0M -0M -M BS1 BS1 BS BS1 BS

SMC Auto Switch Variations

SMC Auto Switch Variations SMC Auto Variations Mounting Function Style method Electrical entry Auto switch model No. Page D-C7/C7/C80 D-B5/B54/B4 5.-9 5.- Connector D-C7C/C80C 5.- Terminal conduit D-A/A4 D-AA/A4A 5.- 5.- DIN terminal

More information

2 Pneumatics. Auto Switch Guide. Applicable Cylinder Series 1 CDA2-X1184 MDB-X1184 CDQ2-XB14 CDG5 S HYDB CDJ5 S CDJP2 CDQM MDU CDQS HYDQ CDJ2 MDB1

2 Pneumatics. Auto Switch Guide. Applicable Cylinder Series 1 CDA2-X1184 MDB-X1184 CDQ2-XB14 CDG5 S HYDB CDJ5 S CDJP2 CDQM MDU CDQS HYDQ CDJ2 MDB1 Best 2 Pneumatics Auto Switch Guide Applicable Cylinder Series 1 Cylinder series CDJP2 CDJ2 CDM2 CDG1 MDB MDB-X1184 MDB1 CDA2 CDA2-X1184 CDS1 CDS2 CDUJ CDU CDQS CDQ2 CDQ2-XB14 RDQ CDQM MDU CDJ S CDG S

More information

CDA2-X1184 MDB-X1184 MDB1 CDA2 CDUJ CDU CDS1 CDS2. ø12 to ø20. ø125 to ø160. ø6 to ø32. ø6 to ø10 P.1516

CDA2-X1184 MDB-X1184 MDB1 CDA2 CDUJ CDU CDS1 CDS2. ø12 to ø20. ø125 to ø160. ø6 to ø32. ø6 to ø10 P.1516 Best 2 Pneumatics Auto Switch Guide Applicable Cylinder Series 1 Cylinder series CDJP2 CDJ2 CDM2 CDG1 MDB MDB-X1184 MDB1 CDA2 CDA2-X1184 CDS1 CDS2 CDUJ CDU CDQS CDQ2 CDQ2-XB14 RDQ CDQM MDU CDJ S CDG S

More information

Applicable Cylinder Series

Applicable Cylinder Series Auto Switch Guide Applicable Cylinder Series Applicable Cylinder Series 1 A Solid state auto switches Reed auto switches Cylinder series Bore size D-H7 D-H7C D-H7BA D-H7NF D-H7W D-G5/K5 D-G5BA D-G59F D-G5NT

More information

Reed Switches/Direct Mounting Type D-Z73/Z76/Z80

Reed Switches/Direct Mounting Type D-Z73/Z76/Z80 Reed es/direct Mounting Type D-Z73/Z76/Z80 uto Internal Circuits Lead wire colors inside [ ] are old colors prior to conformity with IEC standards. D-Z73 Reed LED Resistor Zener diode Contact box (+) ()

More information

Series MXU ø6, ø10, ø16

Series MXU ø6, ø10, ø16 Compact Slide Series ø, ø, ø1 Displacement accuracy against moments Table edge displacement M1(Pitch moment): 0.02mm or less M2(Yaw moment): 0.01mm or less The miniature linear guide improves the linear

More information

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes 2,, Finger Air Gripper Auto Switch Common Specifications Auto Switch Common Specifications Operating time Impact resistance Insulation resistance Withstand voltage Ambient temperature Enclosure Solid state

More information

2 4times. Compact Cylinder/Guide Rod Type. ±0.2 or less. Guide Rod. Load can be directly mounted.

2 4times. Compact Cylinder/Guide Rod Type. ±0.2 or less. Guide Rod. Load can be directly mounted. CAT.ES-19 A -UK Compact Cylinder/Guide Rod Type Lateral Load Resisting 24times Compared to compact cylinder series CQ Non-rotating accuracy ±0.2 or less Refer to page 3 for details. Guide Rod Load can

More information

Series MGF ø40, ø63, ø100

Series MGF ø40, ø63, ø100 Guide Table Series MGF ø, ø, ø How to Order MGF Z7 Guide table Number of auto switches 2 S 1 Cylinder bore size/ Standard stroke,, 7,,, 7,,, 7, Auto switch Without auto switch * Refer to the table below

More information

Series MXH/ ø6, ø10, ø16, ø20

Series MXH/ ø6, ø10, ø16, ø20 Compact Slide Series / ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. CL MLG CNA CNG MNB CNS CLS CB CV/MVG

More information

2 4times. Compact Cylinder/Guide Rod Type. Guide rod. Load can be directly mounted. Mounting dimensions compatible with the CQS, CQ2 series.

2 4times. Compact Cylinder/Guide Rod Type. Guide rod. Load can be directly mounted. Mounting dimensions compatible with the CQS, CQ2 series. CAT.ES-1 B Compact Cylinder/Guide Rod Type Lateral load resisting 24times Compared to compact cylinder series CQ Non-rotating accuracy ±0.2 or less Refer to page 3 for details. Guide rod ø3,ø,ø0 has been

More information

Series MGC ø20, ø25, ø32, ø40, ø50

Series MGC ø20, ø25, ø32, ø40, ø50 Compact Guide Cylinder Series MGC ø, ø, ø, ø, ø Linear Transfer Unit with compact guide body and front plate Grease nipple offers easy lubrication for bearings Compact front plate and guide body Space

More information

Applicable Auto Switch Variations

Applicable Auto Switch Variations Rotary Actuators, Air Grippers Applicable Auto Switch Variations Rotary Actuators Applicable Auto Switch Variations Type Auto switch mounting type Electrical entry Applicable series Size CDRA1 30 to 100

More information

Series RSH/RS1H. To stop pallets gently. Stopper cylinder with built-in shock absorber. Heavy Duty Stopper Cylinder. ø20, ø32 ø50, ø63, ø80

Series RSH/RS1H. To stop pallets gently. Stopper cylinder with built-in shock absorber. Heavy Duty Stopper Cylinder. ø20, ø32 ø50, ø63, ø80 CAT.ES-118 B Heavy Duty Stopper Cylinder Series RSH/RS1H ø, ø ø, ø, ø To stop pallets gently Stopper cylinder with built-in shock absorber Heavy Duty Stopper Cylinder Series RSH/RS1H ø, ø ø, ø, ø To stop

More information

Series MGC ø20, ø25, ø32, ø40, ø50

Series MGC ø20, ø25, ø32, ø40, ø50 Compact Guide Cylinder Series MGC ø, ø, ø, ø, ø Linear Transfer Unit with compact guide body and front plate Grease nipple offers easy lubrication for bearings Compact front plate and guide body Space

More information

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series

High-Precision Digital Pressure Switch 90-ZSE40 /90-ISE40 Series High-Precision Digital Pressure Switch ZSE40 /ISE40 Series Set pressure range 0.00 to.000 Pa For positive pressure How to Order For Positive Pressure ISE40 0 22 SDPC For Vacuum/Compound Pressure ZSE40

More information

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3)

Slide Unit. Bore size. ø15 (2) ø10 (2) ø16 (3) ø20 (2) Ball bushing bearing Slide bearing. ø25 (3) (3) ø32 (3) Slide Unit Series CX/M/L Slide Bearing/CX:ø, ø, ø5 M:ø, ø6, ø0, ø5, ø3 Ball Bushing Bearing/L:ø, ø6, ø0, ø5, ø3 Provided with shock absorbers to absorb impact and noise. The slide unit can absorb energy

More information

Tecnopoint srl Tel Fax

Tecnopoint srl Tel Fax Auto Guide 175 Auto Guide Select an auto switch model according to the series and the mounting style. Size Direct Direct Direct (Round Groove) (Rectangular Groove) (for rotary actuators) Auto Mounting

More information

Compact Type Dual-Rod Cylinder

Compact Type Dual-Rod Cylinder CAT.ES-74 A Compact Type Dual-Rod Cylinder ø, ø, ø2, ø32 additionally released. Series CXSJ /ø, ø0, ø, ø, ø2, ø32 Auto switches can be installed from 3 directions. Reverse mounting Dimensions/Weight Overall

More information

Elliptical design for space-savings

Elliptical design for space-savings Plate Cylinder Series,,,, By adopting an elliptical piston design, a slim, square shaped body has been achieved, resulting in a space-saving cylinder with unrestricted mounting directions. Elliptical design

More information

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,

More information

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32

Slide Unit. CX2/CXWM/CXWL Series. Slide Bearing/CX2:ø10, ø15, ø25 CXWM:ø10, ø16, ø20, ø25, ø32 Ball Bushing Bearing/CXWL:ø10, ø16, ø20, ø25, ø32 Slide Unit CX/M/L Series Slide Bearing/CX:ø0, ø, ø5 M:ø0, ø, ø0, ø5, ø3 Ball Bushing Bearing/L:ø0, ø, ø0, ø5, ø3 Provided with shock absorbers to absorb impact and noise. The slide unit can absorb energy

More information

Series CE2. Brake mechanism added to a stroke reading cylinder which can measure stroke length. Stroke Reading Cylinder with Brake

Series CE2. Brake mechanism added to a stroke reading cylinder which can measure stroke length. Stroke Reading Cylinder with Brake Stroke Reading Cylinder with Brake Series ø, ø, ø, ø, ø Brake mechanism added to a stroke reading cylinder which can measure stroke length. RS A H C G5-S -12-43 Stroke Reading Cylinder with Brake/ Controller/CEU2

More information

Series CY1. Magnetically Coupled Rodless Cylinder. Accuracy. Allowable moment

Series CY1. Magnetically Coupled Rodless Cylinder. Accuracy. Allowable moment Magnetically Coupled Rodless Cylinder Series CY Accuracy Series CYS Series CYR Series CYB Series CYT Series CY Series CY Allowable moment Magnetically coupled cylinders save space and have a wide range

More information

Dual-Rod Cylinder Compact Type

Dual-Rod Cylinder Compact Type CAT.ES-7 B Dual-Rod Cylinder Compact Type New Made to Order additionally released. (For details, refer to page 22.) Auto switch can be installed from 3 directions. Reverse Series CXSJ /ø, ø0, ø, ø, ø2,

More information

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g.

240% 19% reduced. Compact Slide. MXH Series. Improved by up to. With new high rigidity linear guide. 369g. ø6, ø10, ø16, ø g. Compact Slide Series ø, ø, ø, ø RoHS Allowable moment MXS Improved by up to MXQ MXQ 2% MXF MXW MXJ MXP MXY With new high rigidity linear guide MTS Allowable moment improvement illustrated below Allowable

More information

Series MSU. Rotary Table. High Precision. Vane Type/Sizes 1, 3, 7, 20. High precision series MSUA introduced to vane type rotary tables CAT.

Series MSU. Rotary Table. High Precision. Vane Type/Sizes 1, 3, 7, 20. High precision series MSUA introduced to vane type rotary tables CAT. CAT.ES20-90 C Rotary Table Series MSU Vane Type/Sizes 1, 3, 7, 20 Peripheral table deflection Table top deflection mm or less High Precision mm or less Series MSUB Series MSUA High precision series MSUA

More information

Valve Mounted Cylinder Double Acting, Single Rod. How to Order. Electrical entry. L L plug connector M M plug connector. G Grommet

Valve Mounted Cylinder Double Acting, Single Rod. How to Order. Electrical entry. L L plug connector M M plug connector. G Grommet L F Mounting style asic style xial foot style Rod side flange style With auto switch CVJ L CDVJ L 6 6 How to Order pplicable uto Switches/Refer to pages to for further information on auto switches. Type

More information

Dual-Rod Cylinder Compact Type

Dual-Rod Cylinder Compact Type CAT.EUS20-7 B -UK Dual-Rod Cylinder Compact Type New Made to Order additionally released. (For details, refer to page 22.) Auto switch can be installed from 3 directions. Reverse Series CXSJ/ø, ø0, ø,,

More information

Toggle Type Air Gripper

Toggle Type Air Gripper ø2, ø40, ø50, ø6 Ideal for gripping heavy workpiece Toggle mechanism is adopted. Holds workpiece even when pressure drops. The toggle mechanism that activates when the finger closes realizes strong and

More information

Series C95 ø32, ø40, ø50, ø63, ø80, ø100

Series C95 ø32, ø40, ø50, ø63, ø80, ø100 ISO Cylinder Series C ø, ø, ø, ø, ø, ø0 Dimensions conform to ISO 1, VDMA 2, CETOP RP3P. CJ1 CJP CJ2 CM2 C CG1 M C CA1 CS1 Variations Series Action Style asic Standard variations uit-in magnet Stainless

More information

Compatible with an operating environment with coolants.

Compatible with an operating environment with coolants. Water Resistant Cylinder (Pneumatic/ydraulic) Pneumatic: CM/CG1/MB/MB1/CQ/CA/MGP/MGG Series ydraulic: CDKB/CF Series Compatible with an operating environment with coolants. CJ5 CG5 Y Water Resistant Anti-coolant

More information

Series MXY. Air Slide Table Long Stroke. ø6, ø8, ø12. A long-stroke type of Series MXP air slide table with integrated linear guide is newly released.

Series MXY. Air Slide Table Long Stroke. ø6, ø8, ø12. A long-stroke type of Series MXP air slide table with integrated linear guide is newly released. CAT.ES0-17 A -UK Air Slide Table Long Stroke Series MXY ø, ø8, ø1 MXP A long-stroke type of Series MXP air slide table with integrated linear guide is newly released. Use of linear guide provides rigid,

More information

CAT.ES A -UK. Low Profile Air Gripper. Series MHF2. Low profile air gripper with space-saving design is newly released.

CAT.ES A -UK. Low Profile Air Gripper. Series MHF2. Low profile air gripper with space-saving design is newly released. CAT.S-166 A -UK Low Profile Air Gripper Series MHF2 Low profile air gripper with space-saving design is newly released. Low Profile Air Gripper Series MHF2 Height is approximately 1/ the size of an equivalent

More information

Mini Free Mount Cylinder

Mini Free Mount Cylinder Mini Free Mount Cylinder ø, ø, ø, ø, ø, ø1, ø Series CUJ Added ø, ø1, ø bore sizes. Action Double acting Single acting, spring return Double acting Single acting, spring return Double acting Single acting,

More information

Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing. How to Order CY1L 25 H 300 J79W. Load voltage 5 V 200V 100 V 12 V 5 V, 12 V

Magnetically Coupled Rodless Cylinder Slider Type: Ball Bushing Bearing. How to Order CY1L 25 H 300 J79W. Load voltage 5 V 200V 100 V 12 V 5 V, 12 V Magnetically Coupled Rodless Cylinder Slider Type: all ushing earing Series CY1L ø, ø, ø, ø, ø, ø, ø How to Order CY1L H 00 J79W Slider type (all bushing bearing) mm mm mm mm mm mm mm Magnetic holding

More information

CAT.ES A. Pin Clamp Cylinder. Positioning and clamping at one time! Construction. Guide pin. Clamp arm (When unclamped) 10 mm.

CAT.ES A. Pin Clamp Cylinder. Positioning and clamping at one time! Construction. Guide pin. Clamp arm (When unclamped) 10 mm. C.ES2- in Clamp Cylinder Clamp! ositioning and clamping at one time! Construction Guide pin (When unclamped) 1 mm Series CKQ/CLKQ Multiple combinations are possible. position can be selected from 4 different

More information

SeriesMHZL2 How to Order

SeriesMHZL2 How to Order Parallel Type ir Gripper Long Stroke SeriesMHZL2 How to Order 1 2 2 ore size Number of fingers 2 2 fingers 1mm mm 2mm 2mm MHZL2 D S C ction Double acting Single acting (normally open) Single acting (normally

More information

Compact Cylinder ISO Standards [ISO/21287]

Compact Cylinder ISO Standards [ISO/21287] Compact Cylinder ISO Standards [ISO/2] New It is possible to mount small auto switches on surfaces. es can be mounted on any of the surfaces, depending on the installation conditions. Improved flexibility

More information

Auto Switch Guide. Consolidate your auto switches. Simplify your onsite inventory control. Band mounting Rail mounting.

Auto Switch Guide. Consolidate your auto switches. Simplify your onsite inventory control. Band mounting Rail mounting. mounting mounting Auto Guide Groove mounting Tie-rod mounting Consolidate your auto switches. Simplify your onsite inventory control. Contents - Auto Guide Section Auto Guide Select an auto switch model

More information

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) 817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global

More information

Made to Order Common Specifications

Made to Order Common Specifications to Common to Common P..4-1 q-xa to A3 Change of rod end shape w-xb Oversized rod e- Heat resistant (1 C) r-xb7 Cold resistant t-xb9 Low speed y-xb1 Intermediate stroke (Exclusive body use) u-xb11 Long

More information

Series MGP. Compact Guide Cylinder. New end lock type introduced to Series MGP. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

Series MGP. Compact Guide Cylinder. New end lock type introduced to Series MGP. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 Compact Guide Cylinder Series ø, ø, ø, ø2, ø, ø, ø, ø, ø, ø0 New end lock type introduced to Series.22- CL MLG CN CNG MNB CNS CLS CB CV/MVG CXW CXS CXT MX MXU MXH MXS MXQ MXF MXW MXP MG MGQ MGG MGC MGF

More information

Slide Unit. Series CXWM/CXWL. Slide bearing/cxwm: ø10, ø16, ø20, ø25, ø32 Ball bushing bearing/cxwl: ø10, ø16, ø20, ø25, ø32

Slide Unit. Series CXWM/CXWL. Slide bearing/cxwm: ø10, ø16, ø20, ø25, ø32 Ball bushing bearing/cxwl: ø10, ø16, ø20, ø25, ø32 Slide Unit Series M/ Slide bearing/m: ø10, ø16, ø0, ø5, ø3 Ball bushing bearing/: ø10, ø16, ø0, ø5, ø3 Variations Slide unit Provided with shock absorbers to absorb impact and noise. The slide unit can

More information

Guide Table. ø40, ø63, ø100

Guide Table. ø40, ø63, ø100 Guide Table Series MGF ø, ø, ø Low-profile compact cylinder utilizes a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting height greatly reduced Low-profile cylinder

More information

3-Position Rotary Table

3-Position Rotary Table CAT.ES-187 A 3-Position Rotary Table Stop position adjustment range From center: ± Rotation range: 0~95 The desired position is adjustable to between 0 and 95 from the centered position to both the right

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

Series MLGP. Low Profile Guide Cylinder with Lock. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

Series MLGP. Low Profile Guide Cylinder with Lock. ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 CAT.ES-4 A Low Profile Guide Cylinder with Lock Series MLGP,,,, ø,,, ø0 Drop prevention when supply pressure falls or residual pressure is released Drop prevention for press fitting jig Drop prevention

More information

Microspeed Cylinders

Microspeed Cylinders EP97-2-C-UK Microspeed Cylinders CJ2X/CUX/CQSX/CQ2X/CM2X (ø, ø) (ø to ø32) (ø12 to ø25) (ø32 to ø0) (ø to ø) Clean room compatible Series -/11- Achieves stable low speed operation even at 0.5mm/s (1mm/s

More information

140 mm. Mechanically Jointed Rodless Cylinder. Series MY3A/3B. Scale: 100% Height reduced by 36% at the maximum * Overall length reduced by

140 mm. Mechanically Jointed Rodless Cylinder. Series MY3A/3B. Scale: 100% Height reduced by 36% at the maximum * Overall length reduced by CAT.ES0- A Mechanically Jointed Rodless Cylinder Height reduced by 6% at the maximum * Scale: 00% (MYA-00) Overall length reduced by mm at the maximum * Comparison with Series MYB High functionality with

More information

Cylindrical Inductive Proximity Sensor GX-M SERIES

Cylindrical Inductive Proximity Sensor GX-M SERIES Cylindrical Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Features Wide product range Types: DC 3-wire shielded type DC 3-wire non-shielded type DC 2-wire standard type DC

More information

Series MXH. Compact Slide. ø6, ø10, ø16, ø20

Series MXH. Compact Slide. ø6, ø10, ø16, ø20 CAT.EUS-12 B -UK Compact Slide Series MXH ø, ø, ø1, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Made to Order -XB13:

More information

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES. Cylindrical Sensors Photoelectric Sensor CY-100 SERIES Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Cylindrical Inductive Proximity Sensor GX-M SERIES Cylindrical Photoelectric

More information

Trimmer Auto Switch Series D- 7K/D-R K

Trimmer Auto Switch Series D- 7K/D-R K CAT.ES0-180 B Trimmer Auto Switch Series D- K/D-R K Large work piece OUT1 and OUT are adjustable separately. OUT1 Trimmer OUT Trimmer OUT Medium work piece Small work piece Operating range of sensor (LED

More information

Compact Cylinder/Plate type

Compact Cylinder/Plate type Compact Cylinder/Plate type Series :,,, Width: Reduced by up to % (compared with SMC series) Total length: Reduced by up to % Volume: Reduced by up to 1% Weight: Reduced by up to % (compared with SMC series

More information

Guide Table. MGF Series

Guide Table. MGF Series Guide Table MGF Series ø, ø, ø0 Low-profile compact cylinder utilizes a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting height greatly reduced Low-profile cylinder

More information

New cylinder body allows small auto switches to be mounted on 4 surfaces.

New cylinder body allows small auto switches to be mounted on 4 surfaces. Toggle Type Air Gripper ø32, ø4, ø5, ø63 New cylinder body allows small auto switches to be mounted on 4 surfaces. RoH Auto switch mounting rail removed. A round slot for mounting small auto switches is

More information

140 mm. Mechanically Jointed Rodless Cylinder. Series MY3A/3B. Scale: 100% Height reduced by 36% at the maximum * Overall length reduced by

140 mm. Mechanically Jointed Rodless Cylinder. Series MY3A/3B. Scale: 100% Height reduced by 36% at the maximum * Overall length reduced by CT.ES0- Mechanically Jointed Rodless Cylinder Height reduced by % at the maximum * Scale: 00% (MY-00) Overall length reduced by mm at the maximum * Comparison with Series MYB High functionality with reduced

More information

Slide Unit. Series CXWM/CXWL. Slide bearing/cxwm: ø10, ø16, ø20, ø25, ø32 Ball bushing bearing/cxwl: ø10, ø16, ø20, ø25, ø32

Slide Unit. Series CXWM/CXWL. Slide bearing/cxwm: ø10, ø16, ø20, ø25, ø32 Ball bushing bearing/cxwl: ø10, ø16, ø20, ø25, ø32 Slide Unit Series M/L Slide bearing/m: ø10, ø16, ø0, ø5, ø3 Ball bushing bearing/l: ø10, ø16, ø0, ø5, ø3 Variations Slide unit Provided with shock absorbers to absorb impact and noise. The slide unit can

More information

Traveling parallelism: mm. Mounting from the through-holes on the top Tapped for mounting a work piece

Traveling parallelism: mm. Mounting from the through-holes on the top Tapped for mounting a work piece CAT.ES-1 A Air Slide Table Series MXJ Height: mm/width: mm/length: mm (MXJ) Note 1) Front mounting accuracy: 0.01 mm Note ) Top mounting accuracy: 0.0 mm Traveling parallelism: 0.00 mm Integrated front

More information

Guide Table. Series MGF

Guide Table. Series MGF Guide Table Series MGF ø, ø, ø0 Low-profile compact cylinder utilizes a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting height greatly reduced Low-profile cylinder

More information

How to Order. Auto switch. Without auto switch (Built-in magnet) Applicable Auto Switches/Refer to p for further details. Indicator.

How to Order. Auto switch. Without auto switch (Built-in magnet) Applicable Auto Switches/Refer to p for further details. Indicator. Compact Side Series MXU How to Order MXU A90V S Compact side Bore size 1 ø ø ø1 1 2 Stroke mm mm 1mm mm 2mm mm Number of auto switches 2 Auto switch S 1 Without auto switch (Buit-in magnet) Appicabe Auto

More information

CAT.ES Pin Clamp Cylinder. Positioning and clamping at one time! Construction. Guide pin. Clamp arm (When unclamped) 10 mm.

CAT.ES Pin Clamp Cylinder. Positioning and clamping at one time! Construction. Guide pin. Clamp arm (When unclamped) 10 mm. CT.ES2-1 -UK Pin Clamp Cylinder Clamp! Positioning and clamping at one time! Construction Guide pin Clamp arm (When unclamped) 1 mm Series CKQ/CLKQ Multiple combinations are possible. Clamp arm position

More information

Series CY1F. Magnetically Coupled Rodless Cylinder Low Profile Guide Type

Series CY1F. Magnetically Coupled Rodless Cylinder Low Profile Guide Type CAT.ES0-170 A Magnetically Coupled Rodless Cylinder Low Profile Guide Type Series CY1F Size: ø, ø, ø New Series of magnetically coupled rodless cylinder featuring compact and low profile design. CY1F /19/0

More information

Mini Free Mount Cylinder

Mini Free Mount Cylinder Mini Free Mount Cylinder ø, ø, ø, ø, ø, ø1, ø Series CUJ Added ø, ø1, ø bore sizes. Action Double acting Double acting Double acting Double acting Double acting Stroke 1 2 30 3 0 0 Clean series : New additions

More information

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Compact Slide. Series MXH ø6, ø10, ø16, ø20 Compact Slide Series ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Endless track linear guide Series Variations

More information

Series MHZ2/MHZJ2. Parallel Type Air Gripper. Series MHZJ2 with dust cover introduced! New finger options added to Series MHZ2 standard type.

Series MHZ2/MHZJ2. Parallel Type Air Gripper. Series MHZJ2 with dust cover introduced! New finger options added to Series MHZ2 standard type. CAT.E273- B Parallel Type Air Gripper Standard Type With Dust Cover Series MHZ2/MHZJ2 Series MHZJ2 with dust cover introduced! New finger options added to Series MHZ2 standard type. Integrated linear guide

More information

Air Cylinder. New RoHS. Series CJ2. are. added to the mounting types. Improved amount of mounting freedom Head cover with boss is added.

Air Cylinder. New RoHS. Series CJ2. are. added to the mounting types. Improved amount of mounting freedom Head cover with boss is added. ir Cylinder ø1, ø16 Double foot Double-side bossed added to the mounting types. 4 types 7 types Improved amount of mounting freedom Head cover with boss is added. Head flange are Double foot Double-side

More information

A rectilinear rotation unit that compactly integrates a slim cylinder and a rotary actuator.

A rectilinear rotation unit that compactly integrates a slim cylinder and a rotary actuator. Rotary Cylinder MRQ Series :, A rectilinear rotation unit that compactly integrates a slim cylinder and a rotary actuator. The timing of the rectilinear and rotational movements can be set as desired.

More information

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector

High Precision Scale Cylinder. How to Order. Connector. Cable suffix Nil Extension cable C Extension cable & connector Non-rotating Type High Precision Scale Cylinder Series CEP1 ø12, ø How to Order CEP1 12 0 F9N L F High precision scale cylinder Mounting bracket Direct mounting front tapped type Foot type Front flange

More information

How to Order D 30 D M9BW. Made to Order Specifications Bore size Number of. Rod end configuration Cylinder stroke (mm) Nil

How to Order D 30 D M9BW. Made to Order Specifications Bore size Number of. Rod end configuration Cylinder stroke (mm) Nil With auto switch RSG RSDG With auto switch (uilt-in magnet) uilt-in Magnet Cylinder Model If a built-in magnet cylinder without an auto switch is required, there is no need to enter the symbol for the

More information

Heavy Duty Stopper Cylinder

Heavy Duty Stopper Cylinder Heavy Duty Stopper Cylinder Series ø, ø32 To stop pallets gently Stopper cylinder with built-in shock absorber Amount of energy absorption can be adjusted to suit the load. Stops the workpiece gently with

More information

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 3 Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.549~ guide... P.3~ General precautions... P.55~ PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight Compact Guide Cylinder ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100 RoHS Compact Overall length shortened New s ø80, ø100 added. Port thread types NPT, G added. Height shortened JMGP ø32 25 mm stroke

More information

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space

Series CRQ2. Compact Rotary Actuator. Piping can be installed from one end. Body can be used as a flange Compact design saves mounting space Compact Rotary Actuator Series CR2 Rack Pinion Style/:,,,, Piping can be installed from one end Uses internal cushioning, : Rubber bumper,, : Air cushion Angle adjustment bolts are standard Use of double

More information

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8

Precision Cylinder. MTS Series. ø8, ø12, ø16, ø20, ø25, ø32, ø40 MXH MXS MXQ MXQ MXF MXW MXJ MXP MXY MTS D- -X. Series Variations MTS8 Precision Cylinder Series, ø, ø6, ø, ø, ø, ø MXS Series Variations Model 8 Standard stroke (mm) 7 7 Rod end configuration Cushion Rubber bumper End lock Made to Order Rod Variable stroke/ through-hole

More information

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2

Rotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2 Rotary Actuator Vane Type 1, 15, 2, 3, 4 Standard Type Free Mount Type Many combinations available! Standard type/series Piping ports are located on the flat surface. Fittings can be secured firmly, piping

More information

SA1W: Water Detection Sensors

SA1W: Water Detection Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com The SA1W is the fastest, most reliable

More information

EX-F70 SERIES EX-F60 SERIES

EX-F70 SERIES EX-F60 SERIES 85 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES General terms and conditions... F-17 General precautions... P.105 Sensor selection guide... P.81~ Korea s S-mark... P.110 PHOTO

More information

How to Order. Standard stroke (mm) ø10 15, 30, 45, 60

How to Order. Standard stroke (mm) ø10 15, 30, 45, 60 ingle Acting, ingle Rod, pring Return/Extend eries K ø, ø pring extend pring return B L D Without auto switch With auto switch mm mm Basic Axial foot Rod side flange Double clevis K L CDJ2K L How to Order

More information

Series CRJ. Mini-Rotary Actuator. Rack-and-Pinion Type/Size: 05, 1

Series CRJ. Mini-Rotary Actuator. Rack-and-Pinion Type/Size: 05, 1 CAT.ES20-160 A Mini-Rotary Actuator Series CRJ Rack-and-Pinion Type/Size: 05, 1 PAT. PEND In our pursuit of excellence in size and weight reduction, we proudly announce the release of the Series CRJ Mini-Rotary

More information

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA

Reed, Electronic. MOVEMENT > Series CST-CSV-CSH proximity switches GENERAL DATA > Series CST-CSV-CSH proximity switches Series CST - CSV and CSH magnetic proximity switches Reed, Electronic» Designed to fit into the grooves provided in the profile barrel of the cylinder» The three

More information

Series MXP. Precision Air Slide Table. ø6, ø10, ø12, ø16. Size ø6 (with stroke adjuster and auto switches) and shock absorber introduced to series MXP

Series MXP. Precision Air Slide Table. ø6, ø10, ø12, ø16. Size ø6 (with stroke adjuster and auto switches) and shock absorber introduced to series MXP CT.ES-12 Precision ir Slide Table ø, ø, ø12, ø1 Size ø (with stroke adjuster and auto switches) and shock absorber introduced to series MXP Cylinder built into a linear guide High rigidity and high precision

More information

Rectangular-shaped Inductive Proximity Sensor.

Rectangular-shaped Inductive Proximity Sensor. 69 PHOTO PHOTO Rectangular-shaped Inductive Proximity Sensor -F/H SERIES Related Information Amplifi er General terms and conditions... P.1 Sensor selection guide...p.11~ / P.67~ Glossary of terms... P.19

More information

Compact Cylinder: Large Bore Size Type Double Acting, Double Rod. How to Order. Cushion C Rubber bumper. Action. D Double acting

Compact Cylinder: Large Bore Size Type Double Acting, Double Rod. How to Order. Cushion C Rubber bumper. Action. D Double acting Compact Cylinder: Large Bore Size Type Double Acting, Double Rod Series CQ2W ø, ø, ø, ø, ø Without auto switch With auto switch B Built-in magnet CQ2WB CDQ2WB Double rod ounting style Through-hole/Both

More information

Compact Guide Cylinder

Compact Guide Cylinder Compact Guide Cylinder Series ø, ø, ø, ø, ø, ø, ø, ø, ø, ø ir cylinder with guide integrated that has achieved anti-lateral load and high non-rotating accuracy. Space-saving cylinder. Suitable as stoppers

More information

Lube, Non-lube: ø125, ø140, ø160, ø180, ø200, ø250, ø300 Air-hydro: ø125, ø140, ø160. How to Order. Bore size. 125mm 140mm 160mm

Lube, Non-lube: ø125, ø140, ø160, ø180, ø200, ø250, ø300 Air-hydro: ø125, ø140, ø160. How to Order. Bore size. 125mm 140mm 160mm ir Cylinder/tandard eries C, : ø, ø, ø, ø, ø, ø, ø : ø, ø, ø How to Order B L F G C D T C L Mounting Foot Front flange Rear flange ingle clevis Double clevis Center trunnion JR Rod boot/cushion Rod boot

More information

Air Cylinder. New. New RoHS. 6 types. Series CJ2. are. added to the mounting types. 4 types 7 types

Air Cylinder. New. New RoHS. 6 types. Series CJ2. are. added to the mounting types. 4 types 7 types ir Cylinder Ø 6, Ø 1, Ø New RoS Double foot ead flange Double-side bossed added to the mounting types. 4 types 7 types New or Ø 6, 3 types are 6 types Double foot Double-side bossed ead flange ead cover

More information

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2 The SA1W is the fastest, most reliable liquid detection sensor on the market. Using a laser beam tuned to the resonant frequency of an H 2 O molecule, the SA1W is able to detect any liquid containing water

More information

Not affected by drops, bubbles or froth

Not affected by drops, bubbles or froth PARTICULAR USE SENSORS SERIES Sensor Detects water...reliably! Strong penetration power Not affected by drops, bubbles or froth Conforming to EMC Directive UL Recognition (Excluding m cable length type)

More information

Vane Type Rotary Actuator 50, 63, 80, 100

Vane Type Rotary Actuator 50, 63, 80, 100 Vane Type Rotary Actuator 5, 63, 8, 1 New Compact auto switches are mountable! (D-M9 ) Compact auto switch D-M9 Stainless steel specification for main parts : 5, 63, 8, 1 Special screw Hexagon socket head

More information

Vane Type Rotary Actuator

Vane Type Rotary Actuator Vane Type Rotary Actuator 5, 63, 8, 1 New Compact auto switches are mountable! (D-M9 ) Compact auto switch D-M9 Stainless steel specification for main parts : 5, 63, 8, 1 Special screw Hexagon socket head

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Air Cylinder: Standard Type Double Acting, Single Rod. How to Order. Standard stroke (mm) ø6 15, 30, 45, 60. Cushion Nil A

Air Cylinder: Standard Type Double Acting, Single Rod. How to Order. Standard stroke (mm) ø6 15, 30, 45, 60. Cushion Nil A ø, ø, ø L F D Without auto switch With auto switch style asic style Axial foot style Rod side flange style Double clevis style (Except ø) ore size mm mm mm How to Order Standard stroke (mm) ø,,, ø,,,,

More information

Coolant Valve SGC2 :155 SGC3 :284 SGC4 :440. million cycles or more. Service life: 5 million cycles or more 5 Service life: million cycles or more

Coolant Valve SGC2 :155 SGC3 :284 SGC4 :440. million cycles or more. Service life: 5 million cycles or more 5 Service life: million cycles or more Flow rate v factor (in case of 0.5 MPa specification) specification) SC :55 SC :8 SC :0 Coolant Valve Series SC For 0.5 MPa/.0 MPa/.6 MPa million cycles or more (based on SMC s test condition) (based on

More information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information Flat Inductive Standard Flat s in Many Different Variations Only 6 mm thick yet provides a sensing distance of mm (MC1). Aluminum die-cast models also available. Be sure to read Safety Precautions on page

More information

Round Type Hydraulic Cylinder

Round Type Hydraulic Cylinder Round Type ydraulic Cylinder CM Series CQ CK C CM CS C C D- CM Series ominal pressure: 3. MPa ore size :,,, 3 3. MPa Round Type ydraulic Cylinder CM Series ø, ø, ø, ø pplicable uto Switches/Refer to pages

More information

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety SERIES Micro-size Inductive Proximity -wire available PNP output Oil resistant Flexible cable Different freq. available available available Amplifier Built-in High performance in micro-size design GA-/GH

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

Miniature Guide Rod Cylinder ±0.1. Mounting from 2 directions

Miniature Guide Rod Cylinder ±0.1. Mounting from 2 directions Miniature Guide Rod Cylinder Series Non-rotating accuracy : Height ±0.1 Mounting from 2 directions idth Overall length Two auto switches can be mounted even for mm strokes Integral wiring/piping to one

More information