GE Industrial Solutions. New. Ed. 02. New contactors and starter combinations for demanding applications. GE imagination at work

Size: px
Start display at page:

Download "GE Industrial Solutions. New. Ed. 02. New contactors and starter combinations for demanding applications. GE imagination at work"

Transcription

1 GE Industrial Solutions New Ed 02 New contactors and starter combinations for demanding applications GE imagination at work

2

3 Efficor - new dimension in global contactors dvantages and enefits 2 Introduction 4 Space saving 6 Time saving 8 Secure connection 9 Stock saving 10 Energy efficiency design 12 Direct online starter 13 Star delta starter 14 Reversing starter dvantages and enefits Order codes Technical data Numerical index 1

4 High installation benefits Smart, various wiring and connectivity technologies fast assembly of starter solutions Smaller product dimensions for panel design and motor control centers integrated auxiliary contacts in standard product Modular and compact motor starter solutions Most reliable technology Time saving Stock saving Space saving Global contactors Standard materials for food & beverage and transportation purposes complying the latest rail standards Highest reliable product performance for worldwide applications Energy efficient design ecological mindset est in class Highest 10d data as per ISO Optimized power per size Lower number of stock keeping units reducing stock complexity for distributors, panelbuilders and OEM customers Outstanding range of power contactors and motor starter solutions including wide range of accessories Energy efficiency pro Standards IE/EN IE/EN IE/EN EN UL 508 S 222/14 VDE 0660/102 pprovals 2

5 Main benefits Time saving Space saving Stock saving Secure connection Energy efficiency design Reliable technology Smart connecting omplete range including accessories Full approval list ttractive design ven efficient enefits new dimension in global contactors 3

6 Space saving ompact starter Global contactors Significant space reduction in the cabinet: ompact starter either with thermal overload relay or manual motor starter Starter mounting plates for friendly maintenance (easy removal of MMS Surion and/or contactor) usbar systems and wiring kits allow safe cabling avoiding mistakes, guaranteeing finger safe protection up to 6kV ontactor with manual motor starter Link module for compact starter Full coil access at the bottom ontactor with thermal overload relay Uniformity in compact design Thermal overload relay mounted direct to the contactor ll connections available 4

7 Space saving: reduced depth ompact D contactor New magnet design reducing the depth by 10% Minimizing depth difference between and D 10mm reduction up to 18 14mm reduction up to 40 Space saving: reduced width 55mm est in class 9 up to 40 series in 45mm width 2 auxiliary contacts built in up to 25 series 45mm enefits Space saving: top and bottom voltage supply The voltage can be supplied on top or bottom of the device: 10% reduction in the height of the cabinet ctual Δ10% Efficor 5

8 Time saving Double box terminals Identical torque (22 Nm) for 9 up to 40 contactors No need for different screwdrivers Global contactors No tools needed Mounting or dismounting the contactors on/from the DIN-rail can be done without tools Even for the mounting of accessories and auxiliaries to the contactor no tools are required Quick assembly of direct online starter User friendly design of link modules and base plates to combine manual motor starter and contactor Smart busbar systems and wiring kits 6

9 Easy maintenance of direct online starter The complete starter combination can be removed from the base plate at once enefits The manual motor starter and the contactor can be removed separately from the base plate 7

10 Secure connection Double box terminals Global contactors Double box clamps for the whole range ables from 075mm 2 up to 16mm 2 in the same box clamps terminal for 4kW up to 185kW No risk for loosing cables void temperature rising on the small cable Smart connectivity Design of intelligent base plate Push the lid in order to move the manual motor starter Push the lid in order to move the contactor 8

11 Stock saving Efficor 50% reduction in codes Efficor range compared to the actual one means a significantly reduction of 50% in stock keeping units Due to: uilt-in auxiliary contacts ifrequency coils Safety plasic material (of railway applications) also used in standard products 50% reduction in Less space space and and volume volume in warehouses in enefits Easy identification Self explanatory description of the catalogue number is an important advantage Example: E E: Means Efficor ontactor range 09: 9 in 3 application : Type of control voltage stands for D stands for D 3: Number of main poles 3 stands for 3 poles 4 stands for 4 poles stands for 2 + 2N 11: Number of auxiliary contacts built-in 1 and 1N : Type of terminal stands for ox terminal R stands for Ring terminal 230: oil voltage W: End character for D contactors W stands for Wide voltage and built-in diode L stands for Low consumption 9

12 Energy efficiency D low energy consumption Optimized operating: The combination of electromagnet and permanent magnet, spring and coil ensures low energy consumption eco-design Global contactors Long life span Increased technical performance results in less maintenance costs Reduced flammability risk and lower toxicity For demanding applications as lifts, appliances and transportation Space reduction Space saving: 14mm depth reduction up to 40 More usable space for customer The voltage can be supplied either on top or bottom of the device losed design Offering full protection against pollution Transparent front cover for dust protection No holes in the base - void dust and external particles - Enhances the life of the device - On/Off indication through carrier position eramic applications Heavy duty environments Environments with high pollution degrees Reliable technology est electrical endurance Electrical endurance > 17 million operations 3 category at rated current Reliability data per standard EN ISO E x10 6 ops E x10 6 ops E x10 6 ops Widest temperature operation from -40 to +55 Suitable for extreme temperatures Lowest noise production: 32d Perfect answer to demanding applications like hospitals ompliant with International standards for plastic parts NF & NF DIN & EN Safe ecological plastic for all applications Only one frame covering 9 up to 40 series Three different depths Depth 1: 9 up to 18 Depth 2: 25 Depth 3: 32 up to 40 RoHS 10

13 Main advantages Efficor Time saving Space saving Stock saving Secure connection Energy effiiciency design Reliable technology Smart connecting Main advantages 45mm 11

14 Direct online starter Global contactors 1 2 onnectivity 1 Feeding 2 usbar 3 Manual motor starter 4 over 5 Link module 6 ontactor 7 ase plate

15 Efficor Star delta starter onnectivity 1 Manual motor starter 2 Link module 3 Wiring kit 4 ontactor(s) 5 Mechanical interlock 6 Timer Reversing starter

16 Reversing starter (with thermal overload relay) onnectivity 1 Wiring kit 2 ontactor 3 Mechanical interlock 4 Thermal overload relay Global contactors

17 Reversing starter (without thermal overload relay) onnectivity 1 Manual motor starter 2 Link module 3 Wiring kit 4 ontactor 5 Mechanical interlock 6 ase plate(s) Star delta starter

18 Notes Global contactors 16

19 ontactors 2 3 pole contactors - ox clamp terminals 3 4 pole contactors - ox clamp terminals 4 2-2N contactors - ox clamp terminals 5 uxiliary contactors - ox clamp terminals Spare coils for contactors and auxiliary contactors 6 ox clamp terminals ccessories 7 For contactors 9 For starters dvantages and enefits Order codes Technical data Numerical index 10 Thermal overload relays 1

20 3 pole contactors - Double box terminals Global contactors Max operating current Not inductive load Motors <440V 3Ph 50/60Hz V dmissible power 3 Electrical endurance ux cont ontrol circuit V 440V 500V at 3 N D 1 3 kw kw kw kw Operations Voltage at no Ref no Voltage at no (1) Ref no Pack HP HP HP HP E E09D311012W x E E09D311024W E E09D311036W E E09D311048W E E09D311060W E E09D311072W E E09D311110W E E09D311125W E E09D311230W E E09D311250W E E09D311440W E E09D311024L E E09D311048L E E09D311110L E E09D311230L E E12D311012W x E E12D311024W E E12D311036W E E12D311048W E E12D311060W E E12D311072W E E12D311110W E E12D311125W E E12D311230W E E12D311250W E E12D311440W E E12D311024L E E12D311048L E E12D311110L E E12D311230L E E18D311012W x E E18D311024W E E18D311036W E E18D311048W E E18D311060W E E18D311072W E E18D311110W E E18D311125W E E18D311230W E E18D311250W E E18D311440W E E18D311024L E E18D311048L E E18D311110L E E18D311230L E E25D311012W x E E25D311024W E E25D311036W E E25D311048W E E25D311060W E E25D311072W E E25D311110W E E25D311125W E E25D311230W E E25D311250W E E25D311440W E E25D311024L E E25D311048L E E25D311110L E E25D311230L E E32D300012W x E E32D300024W E E32D300036W E E32D300048W E E32D300060W E E32D300072W E E32D300110W E E32D300125W E E32D300230W E E32D300250W E E32D300440W E E32D300024L E E32D300048L E E32D300110L E E32D300230L E E40D300012W x E E40D300024W E E40D300036W E E40D300048W E E40D300060W E E40D300072W E E40D300110W E E40D300125W E E40D300230W E E40D300250W E E40D300440W E E40D300024L E E40D300048L E E40D300110L E E40D300230L (1) End character: W = Wide voltage and built-in diode L = Low consumption

21 4 pole contactors - Double box terminals Max operating current Not inductive load Motors <440V 3Ph 50/60Hz V dmissible power 1 Electrical Power endurance cont ontrol circuit V 440V 500V at 1 N D 1 3 kw kw kw kw Operations Voltage at no Ref no Voltage at no (1) Ref no Pack E E12D400012W x E E12D400024W E E12D400036W E E12D400048W E E12D400060W E E12D400072W E E12D400110W E E12D400125W E E12D400230W E E12D400250W E E12D400440W E E E12D400024L E E12D400048L E E12D400110L E12D400230L E E18D400012W x E E18D400024W E E18D400036W E E18D400048W E E18D400060W E E18D400072W E E18D400110W E E18D400125W E E18D400230W E E18D400250W E E18D400440W E E E18D400024L E E18D400048L E E18D400110L E18D400230L Order codes E E25D400012W x E E25D400024W E E25D400036W E E25D400048W E E25D400060W E E25D400072W E E25D400110W E E25D400125W E E25D400230W E E25D400250W E E25D400440W E E E25D400024L E E25D400048L E E25D400110L E25D400230L E E32D400012W x E E32D400024W E E32D400036W E E32D400048W E E32D400060W E E32D400072W E E32D400110W E E32D400125W E E32D400230W E E32D400250W E E32D400440W E E E32D400024L E E32D400048L E E32D400110L E32D400230L (1) End character: W = Wide voltage and built-in diode L = Low consumption 3

22 2-2N contactors - Double box terminals Global contactors Max operating current Not inductive load Motors <440V 3Ph 50/60Hz V dmissible power 3 Electrical Power endurance cont ontrol circuit V 440V 500V at 3 N D 1 3 kw kw kw kw Operations Voltage at no Ref no Voltage at no (1) Ref no Pack HP HP HP HP E E12D00012W x E E12D00024W E E12D00036W E E12D00048W E E12D00060W E E12D00072W E E12D00110W E E12D00125W E E12D00230W E E12D00250W E E12D00440W E E E12D00024L E E12D00048L E E12D00110L E12D00230L E E18D00012W E E18D00024W x E E18D00036W E E18D00048W E E18D00060W E E18D00072W E E18D00110W E E18D00125W E E18D00230W E E18D00250W E E18D00440W E E E18D00024L E E18D00048L E E18D00110L E18D00230L E E25D00012W E E25D00024W x E E25D00036W E E25D00048W E E25D00060W E E25D00072W E E25D00110W E E25D00125W E E25D00230W E E25D00250W E E25D00440W E E E E E E32D00012W E E32D00024W x E E32D00036W E E32D00048W E E32D00060W E E32D00072W E E32D00110W E E32D00125W E E32D00230W E E32D00250W E E32D00440W E E E E (1) End character: W = Wide voltage and built-in diode L = Low consumption

23 uxiliary contactors - Double box terminals - Ith 20 ontacts ontrol circuit N D 3 1 Voltage at no Ref no Voltage at no (1) Ref no Pack E ED440012W E ED440024W E ED440036W E ED440048W E ED440060W E ED440072W E ED440110W E ED440125W E ED440230W E ED440250W E ED440440W E E ED440024L E ED440048L E ED440110L ED440230L E ED431012W E ED431024W E ED431036W E ED431048W E ED431060W E ED431072W E ED431110W E ED431125W E ED431230W E ED431250W E ED431440W E E ED431024L E ED431048L E ED431110L ED431230L Order codes E ED422012W E ED422024W E ED422036W E ED422048W E ED422060W E ED422072W E ED422110W E ED422125W E ED422230W E ED422250W E ED422440W E E ED422024L E ED422048L E ED422110L ED422230L atalogue number structure Example: E E: Means Efficor ontactor range : uxiliary ontact : stands for D stands for D 4: vailable contacts 40 4/0N 31 3/1N 22 2/2N 13 1/3N 04 0/4N : Type of terminal stands for ox terminal R stands for Ring terminal 012: oil voltage (012 up to 600V) E ED413012W E ED413024W E ED413036W E ED413048W E ED413060W E ED413072W E ED413110W E ED413125W E ED413230W E ED413250W E ED413440W E E ED413024L E ED413048L E ED413110L ED413230L E ED404012W E ED404024W E ED404036W E ED404048W E ED404060W E ED404072W E ED404110W E ED404125W E ED404230W E ED404250W E ED404440W E E E E (1) End character: W = Wide voltage and built-in diode L = Low consumption 5

24 Spare coils for contactors and auxiliary contactors - ox clamp terminals Voltage Use for at no Ref no Pack Global contactors coil 12Vac E09 E18, E ES1012S Voltage in 50/60Hz 24Vac E09 E18, E ES1024S Vac E09 E18, E ES1042S Vac E09 E18, E ES1048S Vac E09 E18, E ES1110S Vac E09 E18, E ES1120S Vac E09 E18, E ES1208S Vac E09 E18, E ES1230S Vac E09 E18, E ES1240S Vac E09 E18, E ES1400S Vac E09 E18, E ES1440S Vac E09 E18, E ES1480S Vac E09 E18, E ES1500S Vac E09 E18, E ES1575S Vac E09 E18, E ES1600S coil 12Vac E25 E40 ES2012S Voltage in 50/60Hz 24Vac E25 E40 ES2024S Vac E25 E40 ES2042S Vac E25 E40 ES2048S Vac E25 E40 ES2110S Vac E25 E40 ES2120S Vac E25 E40 ES2208S Vac E25 E40 ES2230S Vac E25 E40 ES2240S Vac E25 E40 ES2400S Vac E25 E40 ES2440S Vac E25 E40 ES2480S Vac E25 E40 ES2500S Vac E25 E40 ES2575S Vac E25 E40 ES2600S

25 ccessories for contactors uxiliary contact blocks ontacts ox clamp terminals N EM N EM at no Ref no Pack Frontal auxiliary blocks 2 contacts EF211S EF220S EF202S Lateral auxiliary blocks 4 contacts EF440S EF431S EF422S EF413S EF404S EF422SE ontact block EL220S EL211S EL202S Order codes Mechanical interlock EMI EMI02S Pneumatic timer (1) ox clamp terminals N Time Type at no Ref no Pack s delay ON EPT30S s delay ON EPT60S s delay OFF EPT30SD s delay OFF EPT60SD (1) Use only with contactor coil in voltage ll accessories can be used with all type of contactors 7

26 ccessories for contactors Mechanical latch ox clamp terminals N Use with oil voltage oil voltage at no Ref no Pack 50/60HZ D 5 6 Global contactors 1 E09 up to E18, E 24-32V - EML1S E09 up to E18, E 42-60V - EML1S E09 up to E18, E V - EML1S E09 up to E18, E V - EML1S E09 up to E18, E V - EML1S E09 up to E18, E V - EML1S E25 up to E V - EML2S E25 up to E V - EML2S E25 up to E V - EML2S E25 up to E V - EML2S E25 up to E V - EML2S E25 up to E V - EML2S E09D up to E18D, ED V EML1DS (1) 5 1 E09D up to E18D, ED V EML1DS (1) 5 1 E09D up to E18D, ED V EML1DS (1) 5 1 E09D up to E18D, ED V EML1DS (1) 5 1 E09D up to E18D, ED V EML1DS (1) 5 1 E09D up to E18D, ED - 440V EML1DS (1) 5 1 E25D up to E40D V EML2DS (1) 5 1 E25D up to E40D V EML2DS (1) 5 1 E25D up to E40D V EML2DS (1) 5 1 E25D up to E40D V EML2DS (1) 5 1 E25D up to E40D V EML2DS (1) 5 1 E25D up to E40D - 440V EML2DS (1) 5 (1) No use with D version low consumption Surge suppressor (plug-in) Description Suppressor Voltage at no Ref no Pack type Diode type, D V DI D ESUDI R type, 24-48V R ESUR R type, V R ESUR R type, V R ESUR R type, V R ESUR R type, V R ESUR Varistor type, /D 24-48V V /D ESUV Varistor type, /D V V /D ESUV Varistor type, /D V V /D ESUV Varistor type, /D V V /D ESUV Varistor type, /D V V /D ESUV

27 ccessories for starters Fuseless starter kits Use with Description at no Ref no Pack GPS1 - E09 up to E25 Link module EM1L GPS1 - E32 Link module EM1L GPS2 - E32 and E40 Link module EM2L GPS1 - E09 up to E mm busbar adapter 45x200mm PF23ED GPS2 - E32 up to E mm busbar adapter 54x200 PF23ED E09-E40 45mm busbar adapter empty for ESRSD reversing/star-delta application E09-E40 54mm busbar adapter empty for ESRSD reversing/star-delta application E09-E40 9mm busbar adapter empty for contactor lateral blocks ESLS mm universal busbar support ES60S Lateral protection for universal busbar support ESLP Order codes GPS1 - E09 up to E32 ase plate 45mm EP GPS2 - E32 and E40 ase plate 55mm EP Wiring kits for reversing starters Use with Description at no Ref no Pack E09 up to E25 Suitable to be used for EKS1RV upper and lower connections with and without overload relay with mechanical interlock E32 and E40 Suitable to be used for EKS2RV upper and lower connections with and without overload relay with mechanical interlock Wiring kits for star delta starters Use with Description at no Ref no Pack E09 up to E25 Suitable to be used for EKS1YD upper and lower connections with and without overload relay E32 and E40 Suitable to be used for EKS2YD upper and lower connections with and without overload relay Parallel busbar Use with Description at no Ref no Pack E09 up to E25 Parallel busbar for 2 contactors E E32 and E40 Parallel busbar for 2 contactors E Parallel poles Use with Description at no Ref no Pack E09 up to E25 3 Poles in parallel E3PP E09 up to E25 4 Poles in parallel E4PP E32 and E40 3 Poles in parallel E3PP E32 and E40 4 Poles in parallel E4PP

28 Thermal overload relays Thermal overload relays Setting range Fuses ox clamp terminals M gl-gg Trip class 10 Min Max Use with at no Ref no Pack Global contactors ERT ERT ERT110D ERT110F ERT110G E09 ERT110H ERT110J E ERT110K E18 ERT110L ERT110M ERT110N ERT110P ERT110S ERT110T ERT210N ERT210P E25 ERT210S E32 ERT210T E40 ERT210U ERT210V ERT210W ccessories Use with Description at no Ref no Pack ase for separate mounting ERT1 DIN EN ERT1S ERT2 DIN EN ERT2S Push-button with flexible cable ERT1 05 m RTS m RTSL backside reset RTS Remote electrical reset ERT1 and ERT2 12 V/D RTRR V/D RTRRD V/D RTRRG V/D RTRRJ /415V/D RTRRN /480V/D RTRRU

29 2 onformity to standards 3 Electrical endurance 4 Power circuit 5 ontrol circuit - lternating current Direct current 6 uilt-in auxiliary contacts uxiliary contact blocks 7 Mechanical latch blocks Terminal capacity 8 Thermal mechanical overload relays 9 Technical data 10 oordination tables 14 ontact sequence 16 Terminal numbering according to EN Terminal numbering according to EN Dimensions and weights dvantages and enefits Order codes Technical data Numerical index 1

30 onformity to standards IE/EN G IE/EN UL508 IE/EN UL486E IE/EN S EN50011 NF F16 101/102 EN50012 EN50005 mbient conditions Storage temperature -55º to +80º Operation temperature -40º to +55º -40º to +70º (1) ltitude <2000m (1) From 100% to 110% of rated control voltage, without additional auxiliary blocks pprovals/marking limatic resistance (IE 68-2) Global contactors Mounting positions Installation capabilities With de-rating values -10% connection voltage -10% disconnection voltage with same rated power, data compared to vertical mounting +10% disconnection voltage +10% connection voltage with same rated power, data compared to vertical mounting ontinuous tests 40 / 125 / 56 old (72h) Temperature -40º Dry heat (96h) Temperature +125º Relative humidity < 50% Humid heat (56h) Temperature +40º Relative humidity 95% yclic test (6 cycles) First half-cycle Second half-cycle Humid heat Low temperature +25º Relative humidity 93% Low temperature +55º Relative humidity 95º Terminal capacity and tightening torque onventional Thermal urrent (lth) () Head type E09 - E18 E25 E32 - E40 ox terminals Solid, stranded and finely stranded w/o end sleeve (mm 2 ) Slot & PZ Finely stranded with end sleeve (mm 2 ) Slot & PZ Finely stranded w/o end sleeve (mm 2 ) Slot & PZ WG wires Tightening torque (Nm) (Lb x in) 22 / / / 20 Finely stranded w/o end sleeve (mm 2 ) Slot & PZ WG wires Tightening torque (Nm) (Lb x in) 22 / / / 20 Finely stranded with end sleeve (mm 2 ) Slot & PZ WG wires Tightening torque (Nm) (Lb x in) 22 / / / 20 2

31 Efficor Electrical endurance ategory 1 (3P & 4P contactors) ategory 3 (3P contactors) E09 E12 E18 E25 E32 E09 E12 E18 E25 E32 E Technical data ategory 4 (3P contactors) E09 E12 E18 E25 E32 E

32 Power circuit Global contactors E 09 E 12 E18 E 25 E 32 E 40 Three pole version Rated thermal current Ith at θ 55º () Rated operational current Ie -3 () Rated operational voltage Ue (V) 690V acc IE / 600V acc UL-S Four pole version Rated thermal current Ith at θ 55º () Rated operational voltage Ue (V) 690V acc IE / 600V acc UL-S Three and four pole version Rated insulation voltage Ui (V) 1000V acc IE / 600V acc UL-S Maximum continuous current -1 () Frequency limits (Hz) Making capacity (RMS) (IE ) U = 500V () reaking capacity (RMS) (acc IE-60947) Ue = 500V () Ue = 690V () Short-time current from cold state 1s () s () s () s () min () min () Recovery time (min) Protection against short-circuit with fuses without thermal overload relay oordination type 1 gl-gg (U = 500V, 50k or U = 415V, 80k) () oordination type 2 gl-gg (U = 500V, 50k or U = 415V, 80k) () verage Impedance per pole (mω) Power dissipation per pole -1 (W) (W) Insulation resistance etween adjacent poles (MΩ) >10 >10 >10 >10 >10 >10 etween poles and earth (MΩ) >10 >10 >10 >10 >10 >10 etween input and output (MΩ) >10 >10 >10 >10 >10 >10 4

33 ontrol circuit - lternating current E09 up to E18 E25 up to E40 Rated insulation voltage Ui (V) Standard voltages Us 50Hz (V) Standard voltages Us 60Hz (V) Voltage operating limits 50/60Hz coils Operating 50Hz xus Operating 60Hz xus Pick-up 50Hz xus Pick-up 60Hz xus Drop out 50Hz xus Drop out 60Hz xus Maximum consumption bifrequency coils (cold state) Magnetic circuit closed (50Hz/60Hz) (V) 98 / / 76 Magnetic circuit opened (50Hz/60Hz) (V) 701 / / 138 Power factor Magnetic circuit closed cos ϕ Magnetic circuit opened cos ϕ Opening and closing times Values between +10% Us and 20% Us Making time on energisation () (ms) reaking time on de-energisation () (ms) Values at Us Making time on energisation () (ms) Making time on de-energisation () (ms) Mechanical endurance ifrequency coils (at 50Hz) 10 6 ops Maximum rate -1 at rated power ops/h at rated power ops/h at rated power ops/h at rated power ops/h No load ops/h Technical data ontrol circuit - Direct current oils with Wide voltage range oils with Low consumption E09 up to E18 E25 up to E40 E09 up to E18 E25 up to E40 Rated insulation voltage Ui (V) Standard voltages Us D (V) Operating Limits Operating xus (VD) Pick Up xus (VD) Drop Out xus (VD) Maximum consumption at Us Magnet circuit open and closed (cold state) (W) Opening and closing times Values between +10% Us and 20% Us Making time on energisation () (ms) reaking time on de-energisation () (ms) Values at Us Making time on energisation () (ms) reaking time on de-energisation () (ms) Mechanical endurance 10 6 ops Maximum rate -1 at rated power ops/h at rated power ops/h at rated power ops/h at rated power ops/h No load ops/h

34 Global contactors uilt-in auxiliary contacts E09 up to E25 Rated insulation voltage Ui according to IE (V) 1000 Rated thermal current Ith a θ 55º () 10 Making capacity (rms) acc to IE Ue 400V, 50/60Hz () 105 D-13 Ue 220Vdc () 105 reaking capacity (rms) acc to IE Ue 400V, 50/60Hz () 105 D-13 Ue 220Vdc () 2-15 rated voltage and current Ue-Ie according to IE (V-) 110/ / / / /660-2 according to UL, S 600 D-13 rated voltage and current Ue-le (V-) 24-6 according to IE according to UL, S Q600 Electrical endurance 10 6 ops 02 Minimum operational power (operational safety) 17 V - 5m Short-circuit protection Max fuse class gl-gg without welding () 10 Insulation resistance etween contacts (MΩ) etween contacts and earth (MΩ) >10 Guaranteed no overlap between and N contacts Space 13mm Impedance of the contacts (MΩ) 27 uxiliary contact blocks EF/EL Rated insulation voltage Ui according to IE (V) 1000 Rated thermal current lth at θ 55º () 10 Making capacity (Ieff) according to IE Ue 400V, 50/60Hz () 60 D-13 Ue 220Vdc () 60 reaking capacity (Ieff) according to IE Ue 400V, 50/60Hz () 60 D-13 Ue 220V, D () rated voltage and current Ue-Ie according to IE (V-) 110/ / / / / according to UL, S 600 D-13 rated voltage and current Ue-Ie (V-) 24-4 according to IE according to UL, S Q600 Electrical endurance 10 6 ops 02 Mechanical endurance 10 6 ops 10 Minimum operational current (operational safety) 17-5 V-m Short-circuit protection Max fuse class gl-gg without welding () 10 Insulation resistance etween contacts (MΩ) etween contacts and earth (MΩ) >10 Guaranteed no overlap between and N contacts Space 16mm for EF / 22mm for EL Impedance of the contacts (MΩ) 27 6

35 Mechanical latch blocks Rated insulation voltage Ui (V) 1000 Standard voltages Us: 50 to 60Hz and D (V) & Operating limits 85% to 110% onsumption for unlatching (auto cut-out) 24 to 72V 30W / 25V 110 to 440V 15W / 12V Electrical unlatching control 18 Minimum impulse (ms) Maintained uto cut by internal contact Manual unlatching control y manual push-button Electrical making control Minimum pulse (ms) 40 (auto cut) Manual making control y manual push-button uxiliary contact N -15 utilisation according to IE according to UL/S D-13 utilisation according to IE (V-) (V-) 110/ / / / / Q600 according to UL/S Mechanical endurance 10 6 ops 02 Wiring diagrams Technical data lternating current lternating current / Direct current Terminal capacity Terminal capacity Screw plate EMLS,EMLSD Flexible wire (mm 2 ) 2x05 25 WG wire (mm 2 ) 2x20 14 Standard gauge 3 Tightening torque (Nm/Lb in) 11 / 10 7

36 Global contactors Thermal mechanical overload relays for contactors from 016 to 40 ontrol circuit up to 690V Power circuit ERT1, ERT2: up to 690V Thermal protection against balanced overload Three-pole differential (phase unbalance protection) utomatic ambient temperature compensation Front mounted selector for choosing utilization current Manual trip lever (tripping test) Tripping indicator (0-1) IP20 protection Reset button, 4 positions: - Manual RESET - Manual RESET and STOP - utomatic RESET with STOP - utomatic RESET without STOP Standards IE 7 EN IE EN G UL508 S222/14 VDE 0660 pprovals/marking IE/EN Ui=690V Tripping current 120% of current setting Tripping curves Trip Time (s) Manual RESET Manual RESET and STOP utomatic RESET with STOP utomatic RESET without STOP Single phase old state Three phase old state Three phase Warm state Multiples of setting current 8

37 Thermal mechanical overload relays lass 10 Setting range () Suitable for ll Efficor contactors Main circuit Rated insulation voltage (V) 690 Frequency limits (Hz) ontrol circuit Rated insulation voltage (IE ) Ui (V) 690 Rated thermal current Ith () 10 Operation current rated voltage and current Ue-Ie (V-) 110/ / / / / D-13 - rated voltage and current Ue-Ie (V-) Utilisation according UL and S 600-Q600 Protective fuse type gl () 10 Terminal capacity (mm 2 ) Tightening capacity (Nm) 22 / 20 Terminal capacity lamp terminal - Flexible (mm 2 ) lamp terminal - Standard gauge 6 22 / 20 Technical data mbient conditions Remote electrical reset Storage temperature Operation temperature (compensated) ltitude <2000 m Relative humidity Protection treatment -55º to +80º -25º to +60º without any changes in characteristics 40º, 95% no cond Salt spary test Power consumption 100V D 100W oils not suitable for continuous operating duty t 1 = 1 sec t 2 = 30 sec t 1 = 5 sec t 2 = 90 sec t 1 = 10 sec t 2 = 180 sec (t 1 = ON time t 2 = OFF time) Mounting positions Inclination angle axis Y and Z: ±30 9

38 oordination table Type 2 with 50k at 415V and 500V Thermal Overload Relay urrent Setting range (ac) Rated Power (kw) Rated urrent () "r" urrent (k) "q" urrent (k) Type SPD Rat (ac) 415V ontactor Type Rat (ac) With M as SPD SPD (M) Type Rat (ac) Rated Power (kw) Rated urrent () "r" urrent (k) "q" urrent (k) 500V With Fuse MMS as SPD ontactor SPD ontactor Type Rat (ac) Type Rat (ac) Type Rat (ac) ERT ERT MMS 026 E MMS 026 E Fuse 2 E Fuse 2 E093 9 Global contactors ERT110D ERT110F ERT110G ERT110H ERT110J ERT110K Fuse 4 E Fuse 4 E Fuse 4 E Fuse 4 E Fuse 6 E Fuse 6 E Fuse 6 E Fuse 6 E Fuse 6 E Fuse 6 E Fuse 10 E Fuse 10 E093 9 ERT110L ERT110M ERT110N/ ERT210N ERT110P/ ERT210P ERT110S/ ERT210S ERT110T/ ERT210T ERT210U ERT210V ERT210W Fuse 16 E Fuse 16 E Fuse 20 E Fuse 20 E Fuse 25 E093 9 M 125 E Fuse 25 E Fuse 35 E M 125 E Fuse 35 E Fuse 40 E M 20 E Fuse 40 E Fuse 40 E Fuse 50 E M 30 E Fuse 50 E Fuse 63 E M 30 E Fuse 63 E Fuse 80 E M 50 E Fuse 80 E Thermal overload relays, Trip lass: 10 Rated operational voltage: 415Vac, 500Vac Rated insulation voltage: 690Vac Rated frequency: 50Hz Rated duty: Eight hour duty Pollution degree: 3 Rated conditional short-circuit protection device current: 80k at 415Vac; 50k at 500Vac 10

39 Surion GPS high breaking capacity (Thermal Magnetic) oordination Type 2-65k at 380/400 & 415V Rated Power Motor (1) Manual Motor Starter ontactor ox clamp Links Rated current () atno Rated current (In) kw 380/400V 415V () Thermal current Setting range () Magnetic current () Series Smallest wire u (pvc) (2) 380/415V (mm 2 ) Minimum frontal electrical safety clearence GPS1H E EM1L GPS1H E EM1L GPS1HD E EM1L GPS1HE E EM1L GPS1HE E EM1L GPS1HF E EM1L GPS1HF E EM1L GPS1HG E EM1L GPS1HH E EM1L GPS1HH E EM1L GPS1HJ E EM1L GPS1HK E EM1L GPS1HK E EM1L GPS1HL E EM1L GPS1HM E EM1L GPS1HP E EM1L GPS1HR E EM1L GPS2HS E EM1L32 (mm) atno Technical data (1) urrent are relevant to four pole motors not having special characteristics of torque Inrush currents: 8 time rated current for 1s (2) The minimum cycle cross-sections are referred to an ambient temperature of 30º max in free air and are selected to withstand the maximum let-through energy and the motor rated current esides the user has to consider the drop voltage, the type of laying and ambient temperature 11

40 Record Plus oordination Type 2 at 80k at 380/400 & 415V Motor (1) M ontactor Overload relay ox clamp learance Rated Power Rated current () atno Rated current (In) Thermal urrent Magnetic urrent Operating current dmissible power Setting Range Smallest wire u (pvc) (2) Min frontal electrical safety clearance Global contactors kw 380/400V 415V () Setting range () () Series P(kW) Series 380/415V (mm 2 ) FD E ERT FD E ERT FD E ERT FD E ERT FD E ERT FD E ERT Record Plus oordination Type 2 at 80k at 500/525V Rated Power Motor (1) M ontactor Overload relay ox clamp learance Rated current () atno Rated current (In) kw 380/400V 415V () Thermal urrent Setting range () Magnetic urrent Operating current dmissible power () P(kW) Series Setting Range Smallest wire u (pvc) (2) 380/415V (mm 2 ) mm Min frontal electrical safety clearance FD E ERT FD E ERT FD E ERT FD E ERT mm (1) urrent are relevant to four pole motors not having special characteristics of torque Inrush currents: 8 time rated current for 1s (2) The minimum cycle cross-sections are referred to an ambient temperature of 30º max in free air and are selected to withstand the maximum let-through energy and the motor rated current esides the user has to consider the drop voltage, the type of laying and ambient temperature 12

41 Notes Technical data 13

42 ontact sequence Device Rating asic contactor uilt-in auxiliary uxiliary contact blocks - Front mounted-4p N P contactors 3 E09 E12 E E Global contactors 4P contactors 4 4P contactors 2+2N E32 E40 E12 E18 E09 E12 E18 E25 E32 E ontact sequence (auxiliary contactors) 4P contactors 4 4P contactors 2+2N E09 E12 E18 E25 E09 E12 E18 E

43 uxiliary contact blocks - Front mounted-2p uxiliary contact blocks - Front mounted-2p Technical data

44 Terminal numbering 3P and 4P contactors E09311E25311 E32300E40300 E12400E32400 E1200 E2500 E3200 E09D311E25D311 E32D300E40D300 E12D400E32D400 E12D00 E25D00 E32D00 1 1L1 3L2 5L N 1 1L1 3L2 5L3 1 1L1 3L2 5L3 7L4 1 R1 1L 3L R3 1 1L1 R1 R3 3L2 2 2T1 4T2 6T N 2 2T1 4T2 6T3 2 2T1 4T2 6T3 8T4 2 R2 2T1 4T R4 2 2T1 R2 R4 4T2 Global contactors uxiliary contactors E440 E431 E422 E413 E404 ED440 ED431 ED422 ED413 ED N N N N N N N 21 N 31 N 41 N uxiliary contact blocks - Front mounting EF440 EF404 EF422 EF431 EF EF211 EF220 EF uxiliary contact blocks - Lateral mounting EL20 EL11 EL (104) (94) 73 (104) 81 (92) 71 (102) 81 (92) 74 (103) (93) (103) 82 (91) (101) (91) Mechanical and mechanical/electrical interlock EMI EMI02 01 (02) (02) (01) 02 (01) 16

45 Terminal numbering (continued) Pneumatic timer blocks EPTD EPT Voltage suppressor blocks ESUR ESUDI ESUVI Mechanical latch block EML EMLD c alterna /D Technical data 17

GE Energy Industrial Solutions. New. New contactors & starter combinations for demanding applications. GE imagination at work

GE Energy Industrial Solutions. New. New contactors & starter combinations for demanding applications. GE imagination at work GE Energy Industrial Solutions New New contactors & starter combinations for demanding applications GE imagination at work Efficor - new dimension in global contactors dvantages and enefits 2 Introduction

More information

Efficor. Most reliable technology. High installation benefits. Best in class. Standards. Approvals. Global contactors. Intro. J/X New A.

Efficor. Most reliable technology. High installation benefits. Best in class. Standards. Approvals. Global contactors. Intro. J/X New A. Most reliable technology igh installation benefits lobal contactors Standard materials for food & beverage and transportation purposes complying the latest rail standards ighest reliable product performance

More information

Efficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions

Efficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions fficor* onformity to standards /N 60947-1 04 /N 60947-4-1 UL508 /N 60947-5-1 UL486 /N 60947-5-4 S22- N500 N 16 101/102 N50012 N50005 pprovals/marking mbient conditions Storage temperature -55º to +80º

More information

Series CK. Contactors. Intro. Mounting positions

Series CK. Contactors. Intro. Mounting positions onformity to standards /N 60947-1 N 63-110 S 5424 & 775 /N 60947-4-1 S 1025 NM S 1 NL 419 S 22.2/14 V 0660/102 UL 508 UN 20109 N 50005 pprovals/marking culus RN NOM Lloyd s Register ureau Veritas mbient

More information

Standard voltages. Alternating current (V) /60Hz Alternating current (V)

Standard voltages. Alternating current (V) /60Hz Alternating current (V) Series K Three and four pole contactors 150 to 825 (3) 200 to 1250 (1) ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K13:

More information

Standard voltages. Alternating current (V) /60Hz Alternating current (V)

Standard voltages. Alternating current (V) /60Hz Alternating current (V) Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K3: auxiliary

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

Series MTO. Thermal overload relays. Thermal overload relays. for minicontactors from 0.11 to 14A. Standards. General characteristics.

Series MTO. Thermal overload relays. Thermal overload relays. for minicontactors from 0.11 to 14A. Standards. General characteristics. Series MTO for minicontactors from 011 to 14 ontrol circuit up to 690V Power circuit up to 690V Three-pole differential (phase unbalance protection) utomatic ambient temperature compensation between 25º

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships wwwkmindustrialcorpcom KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents

Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents Definite Purpose ontactors & Starters - July 007 Definite Purpose ontactors & Starters ontents Description Page Product Family Overview pplication Description........................................ -

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays

Low Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page

SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page 3 ulletin 93 ulletin 93 SMP- Overload Relay SMP-3 Overload Relay SMP-2 Overload Relay Product Selection Overview Feature SMP- SMP-2 SMP-3 Self-Powered 3.2: djustment Range Phase Loss Protection Selectable

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

All round protection guaranteed

All round protection guaranteed s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Ambient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity.

Ambient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity. www.we.net Thermal Overload Relays - RW Series Rated for the new industry RW overload relays are an important part of WEG rane of products. s usual in WEG products, an extended operational service life

More information

NEMA Contactors & Starters A200

NEMA Contactors & Starters A200 March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

Standard voltages. Alternating current (V) /60Hz Alternating current (V)

Standard voltages. Alternating current (V) /60Hz Alternating current (V) Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07...K3: auxiliary

More information

ABB s new control and protection devices

ABB s new control and protection devices ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Definite Purpose Control. Product Focus

Definite Purpose Control. Product Focus Product Focus Innovation in Eaton s utler-hammer efinite Purpose (P) ontactors are designed to improve control of refrigeration, air conditioning, ventilation and resistance heating applications. The

More information

60 Series - General purpose relays 6-10 A. Features SERIES

60 Series - General purpose relays 6-10 A. Features SERIES 60 Series - General purpose relays 6-10 60 SERIES Features 60.12 60.13 Plug-in mount 10 General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils

More information

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com

TeSys D, K. Catalogue 2017 'S335' series contactors for electrodomestic applications. schneider-electric.com TeSys D, K Catalogue 2017 'S335' series contactors for electrodomestic applications schneider-electric.com Presentation TeSys D, TeSys K TeSys D, TeSys K: S335 series Best-in-class contactors for electrodomestic

More information

Thermal overload relays Type TA Class 10

Thermal overload relays Type TA Class 10 Thermal overload relays Type TA Class Thermal Overload relays Description Available for starter construction with A Line contactors and separate panel mounting Designed for close couple mounting Separate

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V) Series K Three and four pole contactors 150 to 825 (3) 200 to 1250 (1) ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K13: auxiliary

More information

General purpose relays 6-10 A

General purpose relays 6-10 A 60 SЕRIES General purpose relays 6-10 Shipyards Hoists and cranes Road / tunnel lighting Burners, boilers and furnaces Wood-processing machines Panels for electrical distribution Control panels Control

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability

More information