3RT14 Contactors with 3 Main Contacts

Size: px
Start display at page:

Download "3RT14 Contactors with 3 Main Contacts"

Transcription

1 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e Rated insulation voltage U i (pollution degree 3) V 1000 Permissible ambient temperature in operation when stored to to +80 Degree of protection acc. to IEC and DIN IP 20 (terminal compartment IP 00), coil system IP 40 Coil voltage tolerance C/DC 0.8 to 1.1 x U s Power consumption of the coils (with coil in cold state and 1.0 x U s ) Standard design For US and Canada C operation Hz 50 50/ closing closed DC operation closing = closed W 15 Operating times at 0.8 to 1.1 x U s 1) Break time = opening time + arcing time C operation closing time opening time 17 to to DC operation closing time opening time V V / / / / to to 20 rcing time 10 to 15 Operating times at 1.0 x U s 1) C operation DC operation closing time opening time closing time opening time 18 to to to to 20 Shock resistance Rectangular pulse C and DC operation g/ 6.8/5 and 4/10 Sine pulse C and DC operation g/ 10.6/5 and 6.2/10 Short-circuit protection of contactors without overload relays Main circuit Fuse links, utilization category gl/gg NH 3N of coord. "1" 2 ) 0 Fuse links, utilization category gr SITOR 3NE of coord. "2" 2 ) 0 Control circuit (short-circuit current I k 1 k) Fuse links, utilization category gl/gg DIZED 5SB 10 NEOZED 5SE 10 Miniature circuit-breaker with C-characteristic 10 Operating frequency Operating frequency z in operating per hour C operation DC operation Contactors without overload relays No-load operating 1/h frequency Rated operation for C-1 1/h 0 0 for C-3 1/h Dependence of the operating frequency z on the rated operational current and the rated operational voltage: I z = z --- e 400V /h I U 1) The opening times of the NO contacts and the closing times of the NC contacts increase if the contactor coils are protected against voltage peaks (varistor +2 to 5, diode assemblies 2 to 6 times). 2) ccording to excerpt from IEC (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 3/74 Siemens NS K 2000

2 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Conductor cross-sections Contactor Size 3RT14 46 Screw connections (1 or 2 conductor connections possible) Connection for drilled copper bars Without box terminal With cable lugs (1 or 2 conductor connections possible) Main conductor: Front terminal Back terminal Both terminals with box terminal (acc. to EN ) connected connected connected Finely stranded with end sleeve mm to to 50 max. 2 x Finely stranded without end sleeve mm 2 4 to to 50 max. 2 x Solid mm to to 16 max. 2 x 16 Stranded mm 2 4 to to 70 max. 2 x 50 Ribbon cable (no. x width x thickness) mm 6 x 9 x x 9 x x (6 x 9 x 0.8) WG conductor connections WG 10 to 2/0 10 to 2/0 max. 2 x 1/0 Max. conductor cross-sections mm 18 x 10 If bars larger than 12 x 10 mm are connected, a 3RT E1 terminal cover is necessary to comply with the phase clearance Finely stranded with cable lug mm 2 10 to 50 If conductors larger than mm 2 are Stranded with cable lug mm 2 10 to 70 connected, a 3RT E1 terminal cover is necessary to comply with the WG conductor connections, solid or stranded WG 7 to 1/0 phase clearance Terminal screws M6 (hexagon socket) Tightening torque Nm 4 to 6 (36 to 53 lb.in) uxiliary conductor: Solid mm 2 2 x (0.5 to 1.5); 2 x (0.75 to 2.5) acc. to IEC ; max. 2 x (0.75 to 4) Finely stranded with end sleeve mm 2 2 x (0.5 to 1.5); 2 x (0.75 to 2.5) WG conductor connections, solid or stranded WG 2 x (18 to 14) Terminal screws M3 Tightening torque Nm 0.8 to 1.2 (7 to 10.3 lb.in) Load ratings with C C-1 utilization category, switching resistive load Rated operational currents I e of three-phase loads = 1 (at 60 ) at 40 up to at 60 up to at 1000 V 1000 V Minimum conductor cross-section with I e load at 40 at 60 C-2 and C-3 utilization categories With an electrical endurance of 1.3 million operating mm 2 50 mm 2 50 Rated operational current I e up to 44 of motors with slipring or squirrel-cage rotor at 50 Hz and 60 Hz (at 60 ) Load ratings with DC DC-1 utilization category, switching resistive load L/R 1 ) Number of conducting paths connected in series Rated operational currents I e (at 60 ) 600 V DC-3 and DC-5 utilization categories, shunt and series motors Number of conducting paths connected in series Rated operational currents I e (at 60 ) 600 V Thermal load 10 s current 1 ) 630 Power loss per conducting path at I e /C-1 W ) cc. to VDE 0660 Part 102. Siemens NS K /75

3 3RT13 Contactors with 4 Main Contacts for Switching Resistive Loads Contactor Size (for 0, see page 3/58) 3RT13 /26 S2 3RT RT RT13 46 Mechanical endurance Oper. 10 million Electrical endurance at I e /C-1 Oper. approx. 0.5 mill. Rated insulation voltage U i (pollution degree 3) V Permissible ambient temperature in operation when stored to to +80 Degree of protection acc. to IEC and DIN terminal compartment IP 20 IP 20 IP 00 IP 20 IP 00 IP 20 IP 00 Power consumption of the coils (with coil in cold state and 1.0 x U s ) C operation Hz 50 50/ / / /60 closing closed V 61 64/ /0.74 V / / / / / / / / / /0.31 DC operation closing = closed W Coil voltage tolerance 0.8 to 1.1 x U s Operating times at 0.8 to 1.1 x U s Break time = opening time + arcing time C/DC operation closing time 6 to 30/ 30 to 90 C/DC operation opening time 13 to / 13 to 40 4 to / 50 to to 30/ 15 to to 50/ 110 to to / 14 to / / / / to 60/ 110 to to / 14 to 20 rcing time 10 to to to to 15 Short-circuit protection of contactors without overload relays Main circuit Fuse links, utilization category gl/gg NH 3N, DIZED 5SB, NEOZED 5SE acc. to IEC / EN (VDE 0660 Part 102) of coord. "1" 1 ) of coord. "2" 1 ) Weld-free ) ccording to excerpt from IEC (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 3/76 Siemens NS K 2000

4 3RT13 Contactors with 4 Main Contacts for Switching Resistive Loads Load ratings with C Contactor Size (for 0, see page 3/58) 3RT13 /26 S2 3RT RT RT13 46 C-1 utilization category, switching resistive load Rated operational currents I e (at 40 ) up to 33/ of three-phase loads = 0.95 (at 40 ) 12.5/15 22/26 Minimum conductor cross-section with I e load at 40 mm 2 10/ C-2 and C-3 utilization categories Rated operational currents I e (at 60 ) at 17/ 26 of motors with slipring or squirrel-cage rotor at 50 Hz and 60 Hz 4/5,5 7.5/ Load ratings with DC DC-1 utilization category, switching resistive load (L/R 1 ) Rated operational currents I e (at 40 ) DC-3 and DC-5 utilization categories, shunt and series motors (L/R 15 ) Rated operational currents I e (at 40 ) Number of conducting paths connected in series Number of conducting paths connected in series Siemens NS K /77

5 3RT15 Contactors with 4 Main Contacts for Switching Motors Contactor Size (for 0, see page 3/58) 3RT15 26 S2 3RT15 Mechanical endurance Oper. 10 million Electrical endurance at I e /C-1 Oper. approx. 0.5 million Rated insulation voltage U i (pollution degree 3) V 690 Permissible ambient temperature in operation when stored to to +80 Degree of protection acc. to IEC and DIN IP 20 IP 20 (term. compartment IP 00) Power consumption of the coils (with coil in cold state and 1.1 x U s ) C operation Hz 50 50/ /60 closing closed V / / 0.74 V / / 0.28 DC operation closing = closed W Coil voltage tolerance 0.8 to 1.1 x U s Operating times at 0.8 to 1.1 x U s Break time = opening time + arcing time / / / / 0.37 C/DC operation closing time 6 to 30/30 to 90 4 to /50 to 110 C/DC operation opening time 13 to /13 to to 30/15 to 30 rcing time 10 to to 15 Short-circuit protection of contactors without overload relays Main circuit Fuse links, utilization category gl/gg NH 3N, DIZED 5SB, NEOZED 5SE acc. to IEC / EN (VDE 0660 Part 102) of coord. "1" 1 ) of coord. "2" 1 ) Weld-free ) ccording to excerpt from IEC (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overlaod relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 3/78 Siemens NS K 2000

6 3RT15 Contactors with 4 Main Contacts for Switching Motors Load ratings with C Contactor Size 3RT15 26 S2 3RT15 C-1 utilization category, switching resistive load Rated operational currents I e (at 40 ) up to of three-phase loads = 0.95 (at 40 ) Minimum conductor cross-section with I e load at 40 mm C-2 and C-3 utilization categories Rated operational currents I e (at 60 ) up to 40 of motors with slipring or squirrel-cage rotor at 50 Hz and 60 Hz and Load ratings with DC DC-1 utilization category, switching resistive load (L/R 1 ) Rated operational current I e (at 60 ) Number of conducting paths connected in series DC-3 and DC-5 utilization categories, shunt and series motors (L/R 15 ) Rated operational current I e (at 60 ) 600 V Number of conducting paths connected in series V Siemens NS K /79

7 3RT16 Capacitor Contactors ll technical data not mentioned in the table below is identical to that of the 3RT10 26 contactors for size, to that of the 3RT10 36 contactors for size S2 and to that of the 3RT10 45 contactors for size. Contactor Size 3RT16 26 S2 3RT RT16 46 Capacitor rating for operational voltage 230 V 50/60 Hz 50/60 Hz 5 V 50/60 Hz 50/60 Hz uxiliary contacts mounted (unassigned) dditional auxiliary contacts mountable (laterally) kvar kvar kvar kvar NO 2 NC, 2 NO or 1 NO + 1 NC 0.85 to 1.1 x U s Coil voltage tolerance Max. operating frequency 1/h Electrical endurance Oper. > mbient temperature Specifications IEC /EN (VDE 0660) RT10 Coupling Relays (Interface) for Switching Motors ll technical data not mentioned in the table below is identical to that of the 3RT10 contactors for switching motors listed on page 3/44 onwards. The 3RT10 1. coupling relays cannot be extended with auxiliary switch blocks. Two single-pole auxiliary switch blocks can be mounted onto the 3RT10 2. coupling relays (see accessories on page 3/19). Contactor Size 0 3RT HB4. 0 3RT JB4. 0 3RT KB4. 3RT KB40 Mechanical endurance Oper. 30 million 30 million 30 million 10 million Coil voltage tolerance 0.7 to 1. x U s q 17 V to 30 V Power consumption of the coil (with coil in cold state) at U s 17 V W V W closing = closed 30 V W Permissible residual current of the electronics (with 0 signal) m < 10 m x 24 V < 10 m x < 10 m x < 6 m x U s V U s V 24 V U s U s Surge suppression in the coil no surge suppression with diode with varistor with varistor Operating times of the coupling relays Closing at 17 V Closing time NO Opening time NC 40 to to to to to to to to 0 at 24 V Closing time NO Opening time NC 30 to to to to to to to to 78 at 30 V Closing time NO Opening time NC 20 to to to to to to to to 56 Opening at 17 V to 30 V Closing time NO Opening time NC 7 to to to to 70 7 to to to to 3/80 Siemens NS K 2000

8 ccessories for 3RT1. Contactors acc. to IEC /DIN VDE 04 Part 2021 Solid-state time-delay blocks with semiconductor output 3RT19.6-2C 2D Rated insulation voltage C V 0 0 Pollution degree 3 Overvoltage category III acc. to DIN VDE 0110 Solid-state time-delay auxilary switch blocks 3RT19.6-2E 2F 2G Coil voltage tolerance 0.8 to 1.1 x U s 0.85 to 1.1 x U s 0.95 to 1.05 times 0.95 to 1.05 times rated frequency rated frequency Power consumption at C 230 V, 50 Hz Rated operational currents I e C-140, DC-13 C-15 at C 230 V, 50 Hz DC-13 at 24 V DC-13 at DC-13 W V for 3RT for 3RT19 26 DIZED fuse protection Utilization category gl/gg 4 Operating frequency with I e load, C 230 V with 3RT1016 contactor load, C 230 V Recovery time Minimum ON-period 200 (with OFF-delay) Residual current m w 5 1/h 1/h Voltage drop switched through V w 3.5 Short-time current-carrying capacity 10 (up to 10 ) Setting accuracy w & 15% w & 15% referred to upper limit of scale Repeat accuracy w & 1% w & 1% Mechanical endurance operating 100 x x 10 6 Permissible ambient temperature Degree of protection acc. to IEC in operation when stored to to +85 IP 40 terminals IP 20 to to +85 IP 40 terminals IP 20 Conductor connection solid mm 2 2 x (0.5 to 1.5) 2 x (0.75 to 4) 2 x (0.5 to 1.5) 2 x (0.75 to 4) finely stranded with end sleeve mm 2 2 x (0.5 to 2.5) 2 x (0.5 to 2.5) solid or stranded WG 2 x (18 to 14) 2 x (18 to 14) Terminal screw M3 M3 Tightening torque Nm 0.8 to to 1.2 Permissible mounting position any any Shock resistance Half sine acc. to IEC g/ 15/11 15/11 Vibration resistance acc. to IEC Hz/mm 10 to 55/0. 10 to 55/0. EMC tests basic specification EN ; EN EN ; EN Surge suppression varistor integrated in time-delay relay Siemens NS K /81

9 3R13 Reversing Contactor ssemblies The technical data is identical to that of the 3RT10.. contactors listed on page 3/54 onwards. The s and u approvals only apply to the complete contactor assemblies and not to the components for customer assembly. 3R14 Contactor ssemblies for Star-Delta Starting acc. to IEC and VDE 0660 Part 102 Short-circuit protection with fuses for motor feeders with short-circuit currents up to 50 k and. For thermally delayed overload relays, see Part 4. Size of contactors K1-K3-K2 Rated motor current Overload relay Setting range Permissible short-circuit fuses for starters, comprising contactor assemblies and overload relays (the overload relays must be set to 0.58 times the rated motor current) Single or double infeed 2 ) Fuse links NH 3N NH TYP 3ND u-listed British DIZED 5SB Utilization cat. fuses Standard NEOZED 5SE am CLSS fuses Utilization cat. gl/gg K5 BS88 of coord. 1 ) of coord. 1 ) of coord. 1 ) "1" "2" "2" "1" "2" RU HB0 5.5 to RU JB0 7 to RU B0 11 to RU BB0 14 to RU DB0 20 to S2-S2-50 3RU EB0 22 to S2-S2-3RU FB0 28 to S2-S2-S2 80 3RU GB0 36 to S2-S2-S2 86 3RU HB0 40 to S RU KB0 to S RU LB0 70 to ) ccording to IEC (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 2) The maximum rated motor current must not be exceeded. 3/82 Siemens NS K 2000

10 3R14 Contactor ssemblies for Star-Delta Starting ll technical data not mentioned in the table below is identical to that of the individual 3RT contactors and the 3RU time-delay relays. Starters Sizes S.. - S.. - S.. 3R Mechanical endurance Oper. 3 million Short-circuit protection without overload relay For short-circuit protection with overload relay, see Part 4. Maximum rated current of the fuse Main circuit 1 ) Fuse links, utilization category gl/gg NH 3N, DIZED 5SB, NEOZED 5SE Single or double infeed acc. to IEC / DIN VDE 0660 Part 102 of coord. "1" 1 ) of coord. "2" 1 ) Control circuit Fuse links, utilization category gl/gg DIZED 5SB, NEOZED 5SE (short-circuit current I k 1 k) Miniature circuit-breaker with C-characteristic Size of contactors Unassigned auxiliary contacts of the contactors Line Delta Star Load rating with C-3 utilization category Reversing time up to 10 s Rated operational current of three-phase motors at 50 Hz and K1 K3 K2 3RT RT RT , 6 2 ) if the auxiliary contact of the overload relay is connected in the contactor coil circuit 10, 6 2 ) if the auxiliary contact of the overload relay is connected in the contactor coil circuit See circuit diagra of the control circuit on page 3/93. at 1000 V Operating frequency with overload relay 1/h Load rating with C-3 utilization category Reversing time up to 15 s Rated operational current of three-phase motors at 50 Hz and at 1000 V Operating frequency with overload relay 1/h Load rating with C-3 utilization category Reversing time up to 20 s Rated operational current of three-phase motors at 50 Hz and at 1000 V Operating frequency with overload relay 1/h ) ccording to IEC (VDE 0660 Part 102): of coordination "1": Destruction of the contactor and the overload relay is permissible. The contactor and/or overload relay must be replaced if necessary. of coordination "2": No damage can be tolerated to the overload relay, but contact welding on the contactor is permitted if the contacts can be easily separated. 2) Up to I k 0.5 k; 2. Siemens NS K /83

Technical specifications

Technical specifications Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith

More information

SIRIUS. Answers for industry.

SIRIUS. Answers for industry. s SIRIUS Datasheet 01 nswers for industry. Introduction Contactors and Contactor ssemblies SIRIUS RW Soft Starter Protection Equipment Load Feeders and Motor Starters for Use in the Control Cabinet Monitoring

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name Data sheet CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor

More information

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name Data sheet CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor S0 Product

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name Data sheet CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor

More information

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10 27Overload Relays Overview Combinations of overload relays and contactors SIRIUS 3R 27Overload Relays Contactors Current range A 3RT10 1 Size S00 3/4/5.5 kw 3RT10 2 Size S0 5.5/7.5/11 kw 3RT10 3 Size S2

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name Data sheet CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase

Siemens AG RW BB14 3RW BB14 3RW BB14. per PU three-phase induction opera- Rated Rated power of three-phase Siemens AG 2008 3RW Soft Starters Selection and ordering data 28-1BB14 38-1BB14 47-1BB14 Ambient temperature 40 C Ambient temperature 50 C Size DT Order No. Price Rated Rated power of Rated Rated power

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

For Operation in the Control Cabinet

For Operation in the Control Cabinet As an option the thyristors can also be protected by SITOR semiconductor fuses from short-circuiting so that the soft starter is still functional after a short-circuit (type of coordination ). Three LEDs

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2006 General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

For Operation in the Control Cabinet

For Operation in the Control Cabinet For Operation in the Cabinet 3RW30 for standard applications Overview The SIRIUS 3RW30 soft starters reduce the motor voltage through variable phase control and increase it in ramp-like mode from a selectable

More information

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008

3RW Soft Starters. General data. 6/4 Siemens LV 1 T 2008 General data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Leadership driven by innovation

Leadership driven by innovation s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs) Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry. Protection Equipment Overload Relays Reference Manual 04/2011 Industrial Controls Answers for industry. Protection Equipment 2 3 7 7 8 9 14 1 16 17 18 18 19 20 2 26 27 28 29 30 32 37 38 40 42 Introduction

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

All round protection guaranteed

All round protection guaranteed s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Thermal Overload Relays - WEG RW Series, 2 Pole

Thermal Overload Relays - WEG RW Series, 2 Pole International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be

More information

Low-Voltage Controls and Distribution

Low-Voltage Controls and Distribution Motor Starters, Soft Starters and Load Feeders 3RW30 / 3RW40 Soft Starters Reference Manual April 2009 Low-Voltage Controls and Distribution Motor Starters, Soft Starters and Load Feeders 4 Introduction

More information

Capacitor Switching Contactors Type K3...-A, K3...-K

Capacitor Switching Contactors Type K3...-A, K3...-K Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Contactor Relays 3TH30

Contactor Relays 3TH30 Contactor Relays 3TH30 Reliability and safety are pre-requisites in the choice of the control contactor. Siemens 3TH30 contactor relays satisfy these criteria and thus offer the right choice to the customer.

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

44 SERIES. PCB/Plug-in relays from 6 to 10 A

44 SERIES. PCB/Plug-in relays from 6 to 10 A 44 PCB/Plug-in relays from 6 to 10 44 2 CO power relays with high separation between adjacent contacts Direct PCB or socket mount Type 44.52 -- 2 CO 6 (5 mm pin pitch) Type -- 2 CO 10 (5 mm pin pitch)

More information

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44

3RW40/44 Catalog Supplement July sirius 3RW40 3RW44 RW40/44 Catalog Supplement July 2005 sirius RW40 RW44 Reduced Voltage Electronic Soft Starts Catalog Technical information SIRIUS soft starters /2 Introduction / General data For standard applications

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

General purpose relays 7-10 A

General purpose relays 7-10 A 55 SЕRIES General purpose relays 7-10 utomation for blinds, grilles and shutters Control and management of electric power Shipyards Road / tunnel lighting Hoists and cranes Circuit breakers and switches

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

Protective Devices: Circuit-Breakers 1 )

Protective Devices: Circuit-Breakers 1 ) Protective Devices: Circuit-Breakers 1 ) /2 Introduction SIRIUS circuit-breakers 1 ) up to 100 A / General data /20 For motor protection /22 For motor protection with overload relay function /23 For starter

More information

General technical data. Ambient conditions

General technical data. Ambient conditions Data sheet Overload relay 9...12 A For motor protection Size S00, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset!!! Phased-out product!!!

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

3SE3 1 SIGUARD Position Switches

3SE3 1 SIGUARD Position Switches 3SE3 SIGUARD Position Switches Metal-enclosed, with Moulded Cable Description Technical data Description In harsh industrial environments and in installations with limited space, the small 3SE3 6 and 3SE3

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

BETA Low-Voltage Circuit Protection

BETA Low-Voltage Circuit Protection BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature

More information

Miniature Industrial relay 8-16 A

Miniature Industrial relay 8-16 A 46 SЕRIES Miniature Industrial relay 8-16 utomation for blinds, grilles and shutters Elevators and lifts Shipyards Road / tunnel lighting Hoists and cranes Bottling plant Control panels Panels for electrical

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0 Controlgear Products +27 () 11 97 116 sales@controlgear.co.za Siemens stock items on hand as at Mon, 3/4/218, 14:4 GMT+2 3NA3824-6 LV HRC FUSE LINK S 8A 69AC 25DC 3 3NA3832 LV HRC FUSE LINK GL/GG S 125A

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Series CA6 Contactors

Series CA6 Contactors Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor

More information