Manual Motor Protectors

Size: px
Start display at page:

Download "Manual Motor Protectors"

Transcription

1 88 Manual Motor Protectors UP TO IMM16 Frame IMM32 Frame IMM65 Frame E E High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal overload protection Trip test feature Phase loss protection Complies with IEC and IEC , UL508 Listed (Manual motor controller) UL508 Listed (Combination motor controller starter) CS C.22.2/ UP TO UL HP Ratings Thermal Short Circuit Current Part Number Price Single Phase Three Phase djustable Rating (SCCR) 115V 230V 200V 230V 460V 575V Range () 480V 600V 16 mp Frame, Pushbutton Operator IMM16-P to k 10k IMM16-P to k 10k IMM16-P to k 10k IMM16-P to k 10k IMM16-1P / to k 10k IMM16-1P6 30-1/ /4 3/4 1.0 to k 10k IMM16-2P5 30-1/6 1/2 1/ /2 1.6 to k 10k IMM16-4P0 30 1/8 1/3 3/4 3/ to k 10k IMM16-6P3 30 1/4 1/ / to k 10k IMM /2 1-1/ /2 6.3 to 10 50k 5k IMM to 16 30k 5k 32 mp Frame, Rotary Operator IMM32-P to k 25k IMM32-P to k 25k IMM32-P to k 25k IMM32-P / to k 25k IMM32-1P /2 1/ to k 25k IMM32-1P6 38-1/10 1/4 1/3 3/ to k 25k IMM32-2P5 38-1/6 1/2 1/2 1-1/2 1-1/2 1.6 to k 25k IMM32-4P0 40 1/8 1/3 3/ to k 25k IMM32-6P3 40 1/4 3/4 1-1/2 1-1/ to k 25k IMM /2 1-1/ / to 10 50k 25k IMM to 16 50k 25k IMM / / to 20 50k 25k IMM /2 7-1/ to 25 50k 25k IMM to 32 42k 25k 65 mp Frame, Rotary Operator IMM / to 40 35k 10k IMM to 50 35k 10k IMM to 65 35k 10k 51 UP TO 60HP E468295

2 Manual Motor Protectors (cont d) 89 IM-TDH Through-the-door Handle UL Type 1/IP55 & UL Type 4X/IP65 Padlockable & Defeatable Rotary Handle djustable shafts Shows IMM position I (ON) or O (OFF) vailable in Gray/Black or Red/Yellow Shown attached to Manual Motor Starter (sold separately) TYPE 1 / IP55 & TYPE 4X / IP65 PROTECTION IM-TDH E Part Number Price Handle Color IM-TDH B1 18 Gray/Black IM-TDH Y1 18 Red/Yellow IM-TDH B4X 24 Gray/Black IM-TDH Y4X 24 Red/Yellow IM-TDH B1 19 Gray/Black IM-TDH Y1 19 Red/Yellow IM-TDH B4X 26 Gray/Black IM-TDH Y4X 26 Red/Yellow IM-TDH B4X 24 Gray/Black IM-TDH Y4X 24 Red/Yellow IM-TDH B4X 26 Gray/Black IM-TDH Y4X 26 Red/Yellow Environmental Rating TYPE 1 / IP55 TYPE 4X / IP65 TYPE 1 / IP55 TYPE 4X / IP65 TYPE 4X / IP65 TYPE 4X / IP65 Shaft Length " ( mm) " ( mm) " ( mm) " ( mm) pplicable MMP IMM32 IMM32 IMM65 MOTOR CONTROLS IMM Bus Bars For parallel connection with IMM to contactor power terminals Simplifies wiring and reduces wiring space Multiple bus bars can be combined providing total current rating Total maximum current rating 690VC Link dapters For electrical and mechanical direct connection between IMM and contactor Simplifies wiring and reduces wiring space IM-LNKDP-16F-16MC 7 For IMM16 + IMCxxx-07S to IMCxxx-16S IM-LNKDP-16F-25MC 7 For IMM16 + IMCxxx-25S IM-LNKDP-32F-16MC 7 For IMM32 + IMCxxx-07S to IMCxxx-16S IM-LNKDP-32F-25C 7 For IMM32 + ICxxx-09S to ICxxx-25S (IC contactor C Coils Only) IM-LNKDP-32F-40C 7 For IMM32 + ICxxx-32S to ICxxx-40S (IC contactor C Coils Only) IM-ENCL-16FY IM-LNKDP-32F IM-ENCL-32xx IM-BBS32F-54-4 IM-BBLST IM-BBSHROUD Enclosed Disconnect Stations Conveniently house manual motor protector in sealed enclosure Two cable entry knockouts top and bottom Includes neutral and ground terminals Wide model available to accommodate side mounting accessories IM-ENCL-16FY 16 Standard Disconnect Station with translucent membrane for IMM16, Red/Yellow, IP66 IM-ENCL-32FB 18 Standard Disconnect Station for IMM32, Black, IP55 IM-ENCL-32FY 18 Standard Disconnect Station for IMM32, Red/Yellow, IP55 IM-ENCL-32FWB 20 Wide Disconnect Station for IMM32, Black, IP55 IM-ENCL-32FWY 20 Wide Disconnect Station for IMM32, Red/Yellow, IP55 IM-BBS32F IM-BBS32F mm for 2 IMM16 or IMM32., 63 max. total IM-BBS32F mm for 3 IMM16 or IMM32., 63 max. total IM-BBS32F mm for 4 IMM16 or IMM32., 63 max. total IM-BBS32F mm for 5 IMM16 or IMM32., 63 max. total IM-BBS32F mm for 2 IMM16 or IMM32 w/ side mount aux., 63 max. total IM-BBS32F mm for 3 IMM16 or IMM32 w/ side mount aux., 63 max. total IM-BBS32F mm for 4 IMM16 or IMM32 w/ side mount aux., 63 max. total IM-BBS32F mm for 5 IMM16 or IMM32 w/ side mount aux., 63 max. total IM-BBS32F mm for 2 IMM16 or IMM32 with 2 side mounting aux contacts IM-BBS32F mm for 3 IMM16 or IMM32 with 2 side mounting aux contacts IM-BBS32F mm for 4 IMM16 or IMM32 with 2 side mounting aux contacts IM-BBS32F mm for 5 IMM16 or IMM32 with 2 side mounting aux contacts IM-BBSHROUD 3 Busbar Shroud for unused IM-BBS32F & IM-BBS54F terminals IM-BBLST 9 ccessories Incoming Power Terminal for Bus Bar System, 3-pole, IMM16 & IMM32 IM-UX-F11 IM-LRM-S02 IM-CURLIM-32F uxiliary Contacts IM-UX-F11 8 Front mount, 1 N.O./1 N.C., 250V max IM-UX-S02 10 Left side mount, 2 N.C., 600V max IM-UX-S11 10 Left side mount, 1 N.O./1 N.C., 600V max IM-UX-S20 10 Left side mount, 2 N.O., 600V max larm & Trip Signaling Switch IM-LRM-S02 12 Left side mount, 1 N.O./1 N.C. for short-circuit signaling and 1 N.O./1 N.C. for overload signaling Shunt Release IM-SHR-C24 17 Right side mount, 20-24V, 50/60Hz IM-SHR-C Right side mount, 110V-127V, 50/60Hz IM-SHR-C Right side mount, V, 50/60Hz Undervoltage Release IM-UVR-C24 17 Right side mount, 24V, 50Hz/60Hz IM-UVR-C Right side mount, 110V-120V, 50/60Hz IM-UVR-C Right side mount, /127V, 50/60Hz IM-UVR-C Right side mount, 208V, 60Hz IM-UVR-C Right side mount, 240V, 60Hz IM-UVR-C Right side mount, 2 N.O. Contacts, /480V, 50/60Hz Current Limiter IM-CURLIM-32F 31 Provides enhanced short-circuit interrupt rating: 100k@480V for Mounting dapters IM-MBDOL-32F 13 For DOL Starters, 45mm, use w/ IMM32 + IMCxxx-07S to IMCxxx- 25S or ICxxx-09S to ICxxx-25S IM-MBREV-32F 17 For Reversing Starters, 90mm, use w/ IMM32 + (2) IMCxxx-07S to -25S or (2) ICxxx-09S to -25S IM-MBYDEL-32F 26 For Star-Delta Motor Starters, 90mm, use w/ IMM32 + (2) IMCxxx- 07S to -25S or (2) ICxxx-09S to -25S IM-MNTTB 1 Mounting tabs for (1) IMM16, IMM32 & IMM65 direct mount to any surface using screws, 2pc/pkg Scale Protection Cover IM-SDPC 3 For IMM16, IMM32 & IMM65 adjustment dial Incoming Power Terminals IM-TYPEE-32F 13 For IMM32 IM-TYPEE-65F 25 For IMM65 ONLINE ORDERS FREESHIPPING SMLL PCKGES MIN LTL FREIGHT MIN. SEE INSIDE BCK COVER FOR MORE DETILS

3 90 Manual Motor Protectors (cont d) General Specifications General Specifications IMM16 IMM32 IMM65 Standards IMM Terminal Specifications 16 mp Frame 32 mp Frame 65 mp Frame IEC / , EN / EN , UL508, CS C.22.2/14 Rated Insulation (Ui) & Operating (Ue) Voltage [V] UL/CS: 600V, IEC : 690V Rated Impulse Voltage cc. IEC [kv] 6 Rated Operating Frequency [Hz] 50/60 Overvoltage Category Phase Failure Sensitivity Protection Overload Protection Characteristics (x lu) [] 0.61 to 1 Magnetic Release (x lu) [] 13 Overload Trip Class 10 Total Power Loss Pv t Rated Load Operating Temp [W] 6 6 (1.6 to 16) / 8 (20 to 32) 25 Utilization Category Lifespan Degree of Protection Resistance IEC (Motor Protector) IEC (Motor Starter) III Yes C-3 Mechanical: 100,000 ops., Electrical (le max.): 100,000 ops., Switching Rate (motor start) C-3: 15 ops/hr IP20 Shock resistance: 15g/11ms, Vibration resistance: 10g/5-150Hz Screw Driver Philips #2 Philips #2 llen #4 Terminal Capacity Environmental Conditions Solid - Stranded 1 or 2 conductors (18 to 12 WG) (see IMM Terminal Specs) (see IMM Terminal Specs) Tightening Torque [lb-in] 11 to 16 lb-in (1.2 to 1.7 Nm) 18 to 22 lb-in (2.0 to 2.5 Nm) 55 lb-in (6.2 Nm) mbient Temperature Storage: -58 to 176 F (-50 to 80 C), Operating: -4 to 140 F (-20 to 60 C) Climatic Proofing IEC / IEC ltitude (Up to 6,600ft) ltitude (Up to 6,600ft): Nominal values, Pollution degree: 3, Mounting position: ny Weight [lb] Warranty Terminal Capacity IMM16/IMM32 Drawing (mm 2 ) (WG) 1 or 2 x (1 to 2.5) - 1 or 2 x (2.5 to 6) - 1 or 2 x (14 to 10) 1 x (8) 1 or 2 x (1 to 2.5) 1 or 2 x (2.5 to 6) 1 or 2 x (14 to 10) 10 1 x (10) Terminal Capacity IMM65 Solid Ferrule Stranded Tightening Torque 1 Conductor on Lower Part Only 12 to 2 WG 12 to 2 WG B 2 Conductors, 1 on Upper Part () and 1 on Lower Part (B) 16 to 2 WG 16 to 2 WG 12 to 2 WG 16 to 2 WG 16 to 2 WG 12 to 2 WG 8 to 2 WG 14 to 2 WG 14 to 2 WG 8 to 2 WG 55 lb-in (6.2 Nm) B 1 year Trip Characteristics Extended Rotary Handle Dimensions in(mm) Manual Motor Protector Dimensions in(mm) B C D verage Curves Curve 1: 3 pole Curve 2: Bipolar with phase loss sensitivity Tripping time as function of the current at cold condition. For warm condition (after submitted to the rated operational current - Ie ), the tripping times reduce to approximately 25%. E-Handle Type Min Max Inches (mm) MMS Type IM-THD32 (TYPE 1) ( ) IMM32 IM-TDH32 (TYPE 4X) ( ) IMM32 IM-TDH65 (TYPE 4X) ( ) IMM65 in (mm) Dimensions B C D IMM (76) 1.77 (45) 3.94 (100) 1.77 (45) IMM (98) 1.77 (45) 3.82 (97) 1.77 (45 IMM (157) 2.13 (54) 4.92 (125) 4.50 (114) The characteristics of the magnetic trip are based on the upper value of the setting range for IMM16, IMM32 & IMM65.

4 Miniature Contactors & Overloads / 1 16 Frame E E / to 1 Surface or DIN rail mountable UL508 Listed 50/60Hz C and DC coil versions available Direct-mounting overloads RoHS compliant uxiliary contacts standard (16 Frame) IEC Optional ccessories Include: dditional auxiliary contact blocks Reverse mounting kits and interlocks Surge suppressors Direct mount to Manual Motor Starter (with optional adapter) Miniature Thermal Overload Relays IMC-LCHBLK-16F 3-pole Contactors 3-pole Overloads 2-pole Overloads Price Current Range pplicable Contactor IMOL-16S-P40 IMOLS-16S-P IMOL-16S-P63 IMOLS-16S-P IMCxxx-07S IMOL-16S-P80 IMOLS-16S-P IMCxxx-09S IMOL-16S-1P2 IMOLS-16S-1P IMCxxx-12S IMOL-16S-1P8 IMOLS-16S-1P IMCxxx-16S IMOL-16S-2P8 IMOLS-16S-2P IMOL-16S-4P0 IMOLS-16S-4P IMOL-16S-6P3 IMOLS-16S-6P IMOL-16S-8P0 IMOLS-16S-8P IMCxxx-07S IMCxxx-09S IMOL-16S-010 IMOLS-16S IMCxxx-12S IMOL-16S-012 IMOLS-16S IMCxxx-16S IMOL-16S-015 IMOLS-16S IMOL-16S-017 IMOLS-16S IMOL-25S-023 IMOLS-25S IMOL-25S-032 IMOLS-25S IMCxxx-25S IMH-SMB-25F 4 FMX Separate Mounting Bracket for IMOL-16S to IMOL-25S, screw or DIN-rail mountable IMOL-16S 11 Part Number UL HP Ratings (C3 Motor Load) Optional Price Coil Voltage Single Phase Three Phase Overload 1 N.O. ux Contact 1 N.C. ux Contact 115V 230V 230V 460V 575V Relay 16 Frame Size IMC330-07S-10-C24 IMC330-07S-01-C VC (60Hz) IMC330-07S-10-C120 IMC330-07S-01-C /120VC (50/60Hz) IMC330-07S-10-C240 IMC330-07S-01-C VC (60Hz) 1/ 3/4HP 1-1/ IMC330-07S-10-C480 IMC330-07S-01-C /480VC (7.2) (7) (7) IMOL-16S IMC330-07S-10-DC VDC IMC330-07S-10-DC24 IMC330-07S-01-DC VDC IMC330-09S-10-C VC (60Hz) IMC330-09S-10-C /120VC (50/60Hz) IMC330-09S-10-C VC (60Hz) IMC330-09S-10-C /480VC (50/60Hz) IMC330-09S-10-DC VDC IMC330-09S-10-DC VDC IMC330-12S-10-C VC (60Hz) IMC330-12S-10-C /120VC (50/60Hz) IMC330-12S-10-C VC (60Hz) IMC330-12S-10-C /480VC (50/60Hz) IMC330-12S-10-DC VDC IMC330-12S-10-DC VDC IMC330-16S-10-C24 IMC330-16S-01-C VC (60Hz) IMC330-16S-10-C120 IMC330-16S-01-C /120VC (50/60Hz) IMC330-16S-10-C240 IMC330-16S-01-C VC (60Hz) IMC330-16S-10-C480 IMC330-16S-01-C /480VC (50/60Hz) IMC330-16S-10-DC VDC IMC330-16S-10-DC24 IMC330-16S-01-DC VDC IMC-MECINT-16F Mini Series ccessories 1/3 HP (9.8) 1/ (12.8) 1HP IMC330-16S-10-DC VDC 25 Frame Size (ux contacts sold separately) IMC330-25S-00-C VC (60Hz) IMC330-25S-00-C120 IMC330-25S-00-C /120VC (50/60Hz) VC (60Hz) 1-1/ (22) IMC330-25S-00-C /480VC (50/60Hz) IMC-UX-316-F11 1HP (12) (25) (12) 7-1/ (22) Part Number Price Description uxiliary Contacts IMC-UX-316-F02 4 Front mount, 2 N.C., IMCxxx-07S to -16S Contactors IMC-UX-316-F04 7 Front mount, 4 N.C., IMCxxx-07S to -16S Contactors IMC-UX-316-F11 4 Front mount, 1 N.O./1 N.C., IMCxxx-07S to -16S Contactors IMC-UX-316-F20 4 Front mount, 2 N.O., IMCxxx-07S to -16S Contactors IMC-UX-316-F22 7 Front mount, 2 N.O./ 2 N.C., IMCxxx-07S to -16S Contactors IMC-UX-316-F40 7 Front mount, 4 N.O., IMCxxx-07S to -16S Contactors IMC-UX-325-F02 4 Front mount, 2 N.C., IMCxxx-25S Contactors 7-1/ IMC-UX-325-F11 4 Front mount, 1 N.O./1 N.C., IMCxxx-25S Contactors IMOL-16S 7-1/ 7-1/ IMOL-16S (12) 1 (22) 1 (27) IMOL-16S IMOL-25S IMC-UX-325-F20 4 Front mount, 2 N.O., IMCxxx-25S Contactors Latch Block IMC-LCHBLK-16F 3 For IMCxxx-07S to -16S Contactors Mechanical Interlock Block for Reversing Configuration IMC-MECINT-16F 3 For IMCxxx-07S to -16S, front mount Reverse Wire Kit for Reversing Starters IMC-REVKIT-16F 9 For IMCxxx-07S-01 to -16S-01 (N.C. aux. contactors only). ssemble IMOL-16S to -25S and IMM16 to 32 Surge Suppressors IMC-DIODE-16F-DC600 3 Diode, Front Mount, VDC IMC-RCSURG-25F-C127 3 RC, Front Mount, VC, 50/60Hz IMC-RCSURG-25F-C24 3 RC, Front Mount, 12-24VC, 50/60Hz IMC-RCSURG-25F-C250 3 RC, Front Mount, VC, 50/60Hz IMC-RCSURG-25F-C510 3 RC, Front Mount, VC, 50/60Hz IMC-VRSURG-25F-D127 3 Varistor, Front Mount, VC / VDC IMC-VRSURG-25F-D275 3 Varistor, Front Mount, VC / VDC IMC-VRSURG-25F-D380 3 Varistor, Front Mount, VC / VDC IMC-VRSURG-25F-D48 3 Varistor, Front Mount, 12-48VC / 12-60VDC IMC-VRSURG-25F-D510 3 Varistor, Front Mount, VC 50-60Hz Link dapters IM-LNKDP-16F-16MC 7 For IMM16 + IMCxxx-07S to IMCxxx-16S IM-LNKDP-16F-25MC 7 For IMM16 + IMCxxx-25S IM-LNKDP-32F-16MC 7 For IMM32 + IMCxxx-07S to IMCxxx-16S MOTOR CONTROLS IMC-REVKIT-16F IMC-RCSURG-25F-C127 IM-LNKDP-16F-16MC ONLINE ORDERS FREESHIPPING SMLL PCKGES MIN LTL FREIGHT MIN. SEE INSIDE BCK COVER FOR MORE DETILS

5 2.77(70) 92 Miniature Contactors & Overloads (cont d) E E / to Surface or DIN rail mountable UL508 Listed 50/60Hz C and DC coil versions available IEC Optional ccessories Include: dditional auxiliary contact blocks Reverse mounting kits and interlocks Surge suppressors Dimensions in(mm) IMCxxx-07S to -16S 3.4(86) 2.0(51) / 16 Frame 4-pole Contactors 2 NO Power Poles 2 NC Power Poles Price 4 NO Power Poles Price Coil Voltage 16 Frame Size IMC422-07S-00-C24 13 IMC440-07S-00-C VC (60Hz) IMC422-07S-00-C IMC440-07S-00-C /120VC (50/60Hz) IMC422-07S-00-C IMC440-07S-00-C VC (60Hz) IMC422-07S-00-C IMC440-07S-00-C /480VC IMC422-07S-00-DC12 16 IMC440-07S-00-DC VDC IMC422-07S-00-DC24 16 IMC440-07S-00-DC VDC IMC422-07S-00-DC IMC440-07S-00-DC VDC IMC422-09S-00-C24 14 IMC440-09S-00-C VC (60Hz) IMC422-09S-00-C IMC440-09S-00-C /120VC (50/60Hz) IMC422-09S-00-C IMC440-09S-00-C VC (60Hz) IMC422-09S-00-C IMC440-09S-00-C /480VC IMC422-09S-00-DC12 17 IMC440-09S-00-DC VDC IMC422-09S-00-DC24 17 IMC440-09S-00-DC VDC IMC422-09S-00-DC IMC440-09S-00-DC VDC IMC422-12S-00-C24 14 IMC440-12S-00-C VC (60Hz) IMC422-12S-00-C IMC440-12S-00-C /120VC (50/60Hz) IMC422-12S-00-C IMC440-12S-00-C VC (60Hz) IMC422-12S-00-C IMC440-12S-00-C /480VC IMC422-12S-00-DC12 19 IMC440-12S-00-DC VDC IMC422-12S-00-DC24 19 IMC440-12S-00-DC VDC IMC422-12S-00-DC IMC440-12S-00-DC VDC IMC422-16S-00-C24 19 IMC440-16S-00-C VC (60Hz) IMC422-16S-00-C IMC440-16S-00-C /120VC (50/60Hz) IMC422-16S-00-C IMC440-16S-00-C VC (60Hz) IMC422-16S-00-C IMC440-16S-00-C /480VC IMC422-16S-00-DC12 21 IMC440-16S-00-DC VDC IMC422-16S-00-DC24 21 IMC440-16S-00-DC VDC IMC422-16S-00-DC IMC440-16S-00-DC VDC Screw Mount 1.5(38) 3.3(84) 2.2 (56) 1.8(46) UL HP Ratings (C3 Motor Load) Single Phase Three Phase 115V 230V 230V 460V 575V 1/ (7.2) 1/3 HP (9.8) 1/ (12.8) 1HP 3/4HP 1HP (12) 1-1/ (7) (12) (7) 7-1/ 7-1/ 7-1/ (12) 2.3(58) IMC IMC-UX IMC-LCHBLK-16F or IMC-MECINT-16F 2.0(51) 2.3(58) 4.5(114) IMC IMOL IMOL-16S / -25S 1.77(45) IMCxxx-25S 3.3(84) 2.2(56) 2.3(58) IMC IMC-UX 3.26(83)

6 Miniature Contactors & Overloads (cont d) 93 Miniature Contactor Specifications General Specifications IMCxxx-07S IMCxxx-09S IMCxxx-12S IMCxxx-16S IMCxxx-25S General Purpose Rating () Rated Operational Voltage (V) 12 to 690 Rated Insulation Voltage (V) UL/CS: 600, IEC/VDE 0660: 690 Rated Impulse Voltage IEC (V) 4000 Rated Operating Frequency (Hz) 25 to 400 Degree of Protection Vibration Resistance (5 to 200Hz) IP20 Contactor Open (g) 2 Contactor Closed at Coil (g) 4 Mechanical Endurance (Million ops) 10 (C Coil) / 12 (DC Coil) 3 (C Coil) Electrical Endurance (Million ops) Shock Resistance Contactor Open (g) (1/2 Sin Wave = 11ms) Contactor Closed at Coil (g) Terminal Capacity Main Contacts (WG) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 10) Screw Driver Phillips #2 Phillips #2 Phillips #2 Phillips #2 Phillips #2 Tightening Torque (lb-in) Environmental Conditions mbient Temperature Storage: -67 to 176 F (-55 to 80 C), Operating: -4 to 140 F (-20 to 60 C) Climatic Withstand ccording to IEC Pollution Degree 3 Mounting 35mm DIN-rail cc. DIN EN Weight (lb) Control Circuit Ratings (C/DC COIL) Standard Voltages Coil Operating Limits Coil Consumption (Single coils) Power Factor Operating Time Miniature Overload Specifications General Specifications 12 to 660 (60Hz) Monofrequency Coils (NO LOD) (V) 0.85 to 1.1 Pick-up (V) 0.40 to 0.76 (C-60Hz) / 0.40 to 0.70 (DC) Drop-out (V) 0.25 to 0.65 (C-60Hz) / 0.15 to 0.40 (DC) Sealed (V) 2.5 to to to to to 13.2 Inrush (V) Closed Cos Φ Opened Cos Φ Coil Energization - N.O. (ms) 8 to 20 (C-60Hz) / 10 to 20 (DC) 13 to 16 (C-60Hz) Coil De-energization - N.O. (ms) 5 to 15 (C-60Hz) / 2 to 8 (DC) 13.5 to 17 (C-60Hz) Standards IEC / , UL 508; CS C.22.2/14; VDE 0660/102 Number of Poles 3 Rated Operation & Insulation Voltage [V] UL/CS: 600, IEC : 690 Rated Impulse Voltage, Uimp [kv] 6 Tripping Class 10 Phase Failure Sensitivity Current Direct lternating [Hz] Up to 400 Shock Resistance (IEC ; 1/2 sine wave) [g/ms] 10/11 Power Terminals IP Rating Main Terminals Capacity IMOL Yes Yes IP10 Cross/Slotted Combination Stranded / Solid (UL/CS) [WG] 14-6 Tightening Torque [lb-in] 20 Environmental Conditions mbient Temperature Storage: -58 to 176 F (-50 to 80 C), Operating: -4 to 158 C (-20 to 70 C) Pollution Degree 3 Higher Value of Setting Range 3 Weight [lb] 0.33 uxiliary Contacts Specifications Front uxiliary Contact Rated uxiliary Contacts C-14/15 DC-13/14 UL/CS 1 NO / 1 NC 24V:4, 60V:3.5, 125V:3, 230V:2, 400V:1.5, 500V:0.5, 690V:0.3 24V:1, 60V:0.5, 110V:0.25, 220V:0.1 Rated Thermal Current [] 6 Short Circuit Protection (Time-delay Fuse ) [] 6 C600 ; R300 uxiliary Terminals Capacity [WG] Tightening Torque [lb-in] 13.3 MOTOR CONTROLS ONLINE ORDERS FREESHIPPING SMLL PCKGES MIN LTL FREIGHT MIN. SEE INSIDE BCK COVER FOR MORE DETILS

7 94 Standard Contactors & Overloads 15 E /4HP to 7 DIN rail mountable up to 105 frame UL508 Listed UL and CE Certified IEC Optional ccessories Include: dditional auxiliary contact blocks Replacement coils Mechanical interlock blocks Link adapters for MMS Coil surge suppression Electronic modules 40 Frame Size 80 Frame Size 105 Frame Size Frame Size Frame Size /4HP 7 Contactors Part Number Price Coil Voltage ux. Contacts 18 Frame Size IC330-09S-10-C VC (60Hz) 1 N.O. IC330-09S-10-C /120VC (50/60Hz) 1 N.O. IC330-09S-10-C VC (60Hz) 1 N.O. IC330-09S-10-C /480VC (50/60Hz) 1 N.O. IC330-09S-10-C /600VC (50/60Hz) 1 N.O. IC330-09S-10-DC VDC 1 N.O. IC330-09S-01-DC VDC 1 N.C. IC330-12S-10-C VC (60Hz) 1 N.O. IC330-12S-10-C /120VC (50/60Hz) 1 N.O. IC330-12S-10-C VC (60Hz) 1 N.O. IC330-12S-10-C /480VC (50/60Hz) 1 N.O. IC330-12S-10-C /600VC (50/60Hz) 1 N.O. IC330-12S-10-DC VDC 1 N.O. IC330-12S-01-DC VDC 1 N.C. IC330-18S-10-C VC (60Hz) 1 N.O. IC330-18S-10-C /120VC (50/60Hz) 1 N.O. IC330-18S-10-C VC (60Hz) 1 N.O. IC330-18S-10-C /480VC (50/60Hz) 1 N.O. IC330-18S-10-C /600VC (50/60Hz) 1 N.O. IC330-18S-10-DC VDC 1 N.O. IC330-18S-01-DC VDC 1 N.C. 25 Frame Size IC330-25S-00-C VC (60Hz) - IC330-25S-00-C /120VC (50/60Hz) - IC330-25S-00-C VC (60Hz) - IC330-25S-00-C /480VC (50/60Hz) - IC330-25S-00-DC VDC - 40 Frame Size IC330-32S-00-C VC (60Hz) - IC330-32S-00-C /120VC (50/60Hz) - IC330-32S-00-C VC (60Hz) - IC330-32S-00-C /480VC (50/60Hz) - IC330-32S-00-DC VDC - IC330-40S-00-C VC (60Hz) - IC330-40S-00-C /120VC (50/60Hz) - IC330-40S-00-C VC (60Hz) - IC330-40S-00-C /480VC (50/60Hz) - IC330-40S-00-DC VDC - 80 Frame Size IC330-50S-00-C VC (60Hz) - IC330-50S-00-C /120VC (50/60Hz) - IC330-50S-00-C VC (60Hz) - IC330-50S-00-C /480VC (50/60Hz) - IC330-50S-00-DC VDC - IC330-65S-00-C VC (60Hz) - IC330-65S-00-C /120VC (50/60Hz) - IC330-65S-00-C VC (60Hz) - IC330-65S-00-C /480VC (50/60Hz) - IC330-65S-00-DC VDC - IC330-80S-00-C VC (60Hz) - IC330-80S-00-C /120VC (50/60Hz) - IC330-80S-00-C VC (60Hz) - IC330-80S-00-C /480VC (50/60Hz) - IC330-80S-00-DC VDC Frame Size IC330-95S-00-C VC (60Hz) - IC330-95S-00-C /120VC (50/60Hz) - IC330-95S-00-C VC (60Hz) - IC330-95S-00-C /480VC (50/60Hz) - IC330-95S-00-DC VDC - IC S-00-C VC (60Hz) - IC S-00-C /120VC (50/60Hz) - IC S-00-C VC (60Hz) - IC S-00-C /480VC (50/60Hz) - IC S-00-DC VDC - UL HP Ratings (C3 Motor Load) Optional Single Phase Three Phase Overload 115V 230V 200V 230V 460V 575V Relay (9.8) (10) 0.7 (13.8) 1HP (24) (34) (34) (56) (56) 7. (80) 7. (80) (12) (28) (28) 7. (40) 7. (40) (50) 1 (68) 1 (68) 20HP (100) (88) (9.6) (9.6) (17.5) (15.2) 7. (25) 7. (22) (32.2) (28) 1 (32.2) (42) 1 1 (48.3) (42) 20HP 20HP (62.1) (54) 20HP 2 (62.1) (68) 2 30HP (78.2) (80) 30HP (92) (7.6) 7. (14) 1 (21) 20HP (27) 30HP (40) 40HP (52) 50HP (65) 50HP (65) 60HP (77) 40HP 7 (104) (96) (27) 2 (27) 40HP (41) 50HP (52) 60HP (62) 7 (77) 7 (77) IOL-40S IOL-40S IOL-80S IOL-80S IOL-80S IOL- 105S IOL- 105S

8 Standard Contactors & Overloads (cont d) UP TO 350HP 150 to 300 IC L E Up to 350HP UL508 Listed UL and CE Certified IEC Optional ccessories Include: uxiliary contact blocks Replacement coils Part Number Price Coil Voltage ux. Contacts 150 Frame Size IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. 180 Frame Size IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. 300 Frame Size IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. IC L-22-D VC/DC 2 N.O./2 N.C. UL HP Ratings (C3 Motor Load) Single Phase Three Phase 115V 230V 200V 230V 460V 575V HP (120) 50HP (150) 60HP (177) Optional Overload Relay 50HP 100HP 100HP IOL-150L (130) (124) (99) 60HP HP IOL-150L (154) (156) (144) 7 150HP 200HP IOL-180L (192) (180) (192) 7 100HP 200HP 250HP IOL-300L (221) (248) (240) (242) 100HP HP 350HP IOL-300L (285) (312) (302) (336) MOTOR CONTROLS Contactor ccessories uxiliary Contacts IC-UX-F10 3 Front Mount, 1NO, for ICxxx-09S to -105S contactors IC-UX-F01 3 Front Mount, 1NC, for ICxxx-09S to -105S contactors IC-UX-S11 6 Side Mount, 1NO/1NC for ICxxx-09S to ICxxx-300L contactors IC-UX-S20 6 Side Mount, 2NO, for ICxxx-09S to ICxxx-300L contactors IC-UX-S11X 6 Side Mount, 2nd Block, 1NO/1NC, for ICxxx-09S to ICxxx-300L contactors IC-UX-S20X 6 Side Mount, 2nd Block, 2NO, for ICxxx-09S to ICxxx-300L contactors Mechanical Interlock Blocks IC-MECINT02-105F 11 Side mount between two ICxxx-09S to ICxxx-105S contactors Side mount between two ICxxx-112L to ICxxx-300L contactors w/ IC-MECINT00-300F 22 the same frame size Link dapters (Electrical and Mechanical Direct Connection) IM-LNKDP-32F-25C 7 For IMM32 + ICxxx-09S to ICxxx-25S (IC contactor C Coils Only) IM-LNKDP-32F-40C 7 For IMM32 + ICxxx-32S to ICxxx-40S (IC contactor C Coils Only) Lug Terminals IC-LUGS-150F FMX Lugs for ICxxx-112L to ICxxx-150L, 300 MCM to 6 WG wire 22 size, 3 pack IC-LUGS-180F 26 FMX Lugs for ICxxx-180L, 300 MCM to 6 WG wire size, 3 pack IC-LUGS-300F FMX Lugs for ICxxx-250S to ICxxx-300L, 300 MCM to 6 WG wire 46 size, 3 pack Surge Suppressors IC-VRSURG-105F-C510 6 Varistor, ICxxx-09S to ICxxx-105S, 400 to 510VC IC-RCSURG-40F-C48 8 RC, ICxxx-09S to ICxxx-40S, 24 to 48VC IC-RCSURG-40F-C127 8 RC, ICxxx-09S to ICxxx-40S, 50 to 127VC IC-RCSURG-40F-C250 8 RC, ICxxx-09S to ICxxx-40S, 130 to 250VC IC-RCSURG-105F-C48 8 RC, ICxxx-50S to ICxxx-105S, 24 to 48VC IC-RCSURG-105F-C127 8 RC, ICxxx-50S to ICxxx-105S, 50 to 127VC IC-RCSURG-105F-C250 8 RC, ICxxx-50S to ICxxx-105S, 130 to 250VC IC-RCSURG-250F-C48 8 RC, ICxxx-112L to ICxxx-250L, 24 to 48VC IC-RCSURG-250F-C250 8 RC, ICxxx-112L to ICxxx-250L, 50 to 250VC IC-DIODE-25F-DC600 8 Diode, ICxxx-09S to ICxxx-25S, 12 to 600VDC Replacement Contactor Coils ICR-COIL-25F-C24 9 ICxxx-09 to ICxxx-25, 24VC, 60Hz ICR-COIL-25F-C120 9 ICxxx-09 to ICxxx-25, 110/120VC, 50/60Hz ICR-COIL-25F-C240 9 ICxxx-09 to ICxxx-25, VC, 60Hz ICR-COIL-25F-C480 9 ICxxx-09 to ICxxx-25, /480VC, 50/60Hz ICR-COIL-25F-C600 9 ICxxx-09 to ICxxx-25, 500/600VC, 50/60Hz ICR-COIL-25F-DC24 14 ICxxx-09 to ICxxx-25, 24VDC ICR-COIL-40F-C24 10 ICxxx-32 to ICxxx-40, 24VC, 60Hz ICR-COIL-40F-C ICxxx-32 to ICxxx-40, 110/120VC, 50/60Hz ICR-COIL-40F-C ICxxx-32 to ICxxx-40, VC, 60Hz ICR-COIL-40F-C ICxxx-32 to ICxxx-40, /480VC, 50/60Hz ICR-COIL-40F-C ICxxx-32 to ICxxx-40, 500/600VC, 50/60Hz ICR-COIL-40F-DC24 16 ICxxx-32 to ICxxx-40, 24VDC ICR-COIL-40F-DF ICxxx-32 to ICxxx-40, 208/240VC, 50/60Hz ICR-COIL-105F-C ICxxx-50 to ICxxx-105, 110/120VC, 50/60Hz ICR-COIL-105F-C ICxxx-50 to ICxxx-105, VC, 60Hz ICR-COIL-105F-C ICxxx-50 to ICxxx-105, /480VC, 50/60Hz ICR-COIL-105F-C ICxxx-50 to ICxxx-105, 500/600VC, 50/60Hz ICR-COIL-105F-DC24 21 ICxxx-50 to ICxxx-105, 24VDC Replacement Contactor Coils Frame ICR-COIL-150F-D28* 20 ICxxx-112 to ICxxx-150, 24-28VC/DC*Use w/icr-emod-300f-d28* ICR-COIL-150F-D130* 20 ICxxx-112 to ICxxx-150, VC/DC*Use w/icr-emod-300f-d130* ICR-COIL-150F-D250* 20 ICxxx-112 to ICxxx-150, VC/DC*Use w/icr-emod-300f-d250* ICR-COIL-150F-D500* 20 ICxxx-112 to ICxxx-150, VC/DC*Use w/icr-emod-300f-d500* ICR-COIL-180F-D28* 26 ICxxx-180L, 24-28VC/DC*Use w/icr-emod-300f-d28* ICR-COIL-180F-D130* 26 ICxxx-180L, VC/DC*Use w/icr-emod-300f-d130* ICR-COIL-180F-D250* 26 ICxxx-180L, VC/DC*Use w/icr-emod-300f-d250* ICR-COIL-180F-D500* 26 ICxxx-180L, VC/DC*Use w/icr-emod-300f-d500* ICR-COIL-300F-D28* 33 ICxxx-250 to ICxxx-300, 24-28VC/DC*Use w/icr-emod-300f-d28* ICR-COIL-300F-D130* 33 ICxxx-250 to ICxxx-300, VC/DC*Use w/icr-emod-300f-d130* ICR-COIL-300F-D250* 33 ICxxx-250 to ICxxx-300, VC/DC*Use w/icr-emod-300f-d250* ICR-COIL-300F-D500* 33 ICxxx-250 to ICxxx-300, VC/DC*Use w/icr-emod-300f-d500* Replacement Electronic Modules ICR-EMOD-300F-D28* 71 ICxxx-112 to ICxxx-300, 24-28VC/DC*Use w/ ICR-COIL-xxxx-D28* ICR-EMOD-300F-D130* 71 ICxxx-112 to ICxxx-300, VC/DC*Use w/ ICR-COIL-xxxx-D130* ICR-EMOD-300F-D250* 71 ICxxx-112 to ICxxx-300, VC/DC*Use w/ ICR-COIL-xxxx-D250* ICR-EMOD-300F-D500* 71 ICxxx-112 to ICxxx-300, VC/DC*Use w/ ICR-COIL-xxxx-D500* *Replacement Coils 112 and above must be paired with an Electronic Module IC-UX-F10 IC-UX-S11 IM-LNKDP-32F Lug Terminals Surge Suppressor ONLINE ORDERS FREESHIPPING SMLL PCKGES MIN LTL FREIGHT MIN. SEE INSIDE BCK COVER FOR MORE DETILS

9 96 Standard Contactors & Overloads (cont d) 18 Thermal Overload Relays 3-pole Overloads 2-pole Overloads Price ux Contacts Current Range pplicable Contactor 15 Trip ranges from 0.28 to 420 Separate mount adapter available (through IOL-105S) mbient compensated -4 to 140 F (-20 to 60 C) Selectable RESET button (auto or manual) Differential current / phase loss protection Isolated 1N.O. & 1 N.C. auxiliary contacts Trip class 10 UL and CE Certified UL508 / IEC IOL-80S IOL-105S IOL-40S E P40 IOLS-25S-P N.O. / 1N.C P63 IOLS-25S-P N.O. / 1N.C P80 IOLS-25S-P N.O. / 1N.C P2 IOLS-25S-1P N.O. / 1N.C P8 IOLS-25S-1P N.O. / 1N.C P8 IOLS-25S-2P N.O. / 1N.C P0 IOLS-25S-4P N.O. / 1N.C P3 IOLS-25S-6P N.O. / 1N.C P0 IOLS-25S-8P N.O. / 1N.C IOLS-25S N.O. / 1N.C IOLS-25S N.O. / 1N.C IOLS-25S N.O. / 1N.C IOLS-25S N.O. / 1N.C IOLS-25S N.O. / 1N.C IOLS-25S N.O. / 1N.C ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-32S ICxxx-40S IOL-40S-040 IOLS-40S N.O. / 1N.C ICxxx-32S IOL-40S-050 IOLS-40S N.O. / 1N.C ICxxx-40S IOL-80S-040 IOLS-80S N.O. / 1N.C IOL-80S-050 IOLS-80S N.O. / 1N.C IOL-80S-057 IOLS-80S N.O. / 1N.C IOL-80S-063 IOLS-80S N.O. / 1N.C IOL-80S-070 IOLS-80S N.O. / 1N.C IOL-80S-080 IOLS-80S N.O. / 1N.C IOL-105S N.O. / 1N.C IOL-105S N.O. / 1N.C IOL-105S N.O. / 1N.C IOL-150L-097-LK N.O. / 1N.C IOL-150L-112-LK N.O. / 1N.C IOL-150L-150-LK N.O. / 1N.C IOL-150L-215-LK N.O. / 1N.C IOL-180L-150-LK N.O. / 1N.C IOL-180L-215-LK N.O. / 1N.C IOL-300L-150-LK N.O. / 1N.C IOL-300L-215-LK N.O. / 1N.C IOL-300L-310-LK N.O. / 1N.C IOL-300L-420-LK N.O. / 1N.C Overload ccessories Separate Mount Block IH-SMB-32F 6 For & IOLS-25S IH-SMB-50F 8 For IOL-40S & IOLS-40S IH-SMB-80F 8 For IOL-80S & IOLS-80S IH-SMB-105F 10 For IOL-105L Lug Terminals IH-LUGS For IOL-300L-150 & IOL-300L-215, 3 pack IH-LUGS For IOL-300L-310 & IOL-300L-420, 3 pack IH-LUGSPCR 4 Spacers for IH-LUGS-215 & IH-LUGS-420 (required for UL) ICxxx-50S ICxxx-65S ICxxx-80S ICxxx-95S ICxxx-105S ICxxx-112L ICxxx-150L ICxxx-180L ICxxx-250L ICxxx-300L 130 separate mount block Lug Terminals IOL-150L

10 Standard Contactors & Overloads (cont d) 97 Contactor Dimension Legend in(mm) Overload Dimension Legend in(mm) W H D D H MOTOR CONTROLS Contactor Dimensions Contactor Frame Size Contactor Specifications Contactor ICxxx-09S ICxxx-12S ICxxx-18S ICxxx-25S ICxxx-32S ICxxx-40S ICxxx-50S ICxxx-65S ICxxx-80S ICxxx-95S ICxxx-105S Rated Insulation Voltage (V) UL/CS: 600, IEC/VDE 0660: 1000 Rated Impulse Voltage IEC (kv) Rated Operating Frequency (Hz) 25 to to to to to to to to to to to 400 Degree of Protection H W D in mm in mm in mm 18 (C) (DC) (C) (DC) (C) (DC) (C/DC) (C/DC) (C/DC) (C/DC) (C/DC) Overload Dimensions Main Terminals IP20 IP20 IP20 IP10 IP10 IP10 IP10 IP10 IP10 IP10 IP10 Coil Terminals IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 uxiliary Terminals IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Vibration Resistance Contactor Open (g) (5 to 200Hz) Contactor Closed at (g) Mechanical (Million C Coil Endurance ops) Electrical Endurance C-3 (Million ops) Shock Resistance: Contactor Open /2 Sin Wave = 11ms Contactor Closed at Coil Terminal Capacity Stranded/Solid 1 or 2 1 or 2 1 or 2 1 or 2 (WG) (UL/CS) (14-10) (14-10) (14-10) (14-8) /0 14-1/0 14-1/0 14-1/0 14-1/0 Screw Driver Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 5/32 5/32 5/32 5/32 5/32 Tightening Torque (lb-in) mbient Temperature Storage: -67 to 176 F (-55 to 80 C), Operating (IEC) -13 to 131 F (-25 to 55 C) Environmental Climatic Withstand ccording to IEC Conditions Pollution Degree 3 Mounting 35mm DIN-rail cc. DIN EN Weight (lbs) Warranty 1 year Control Circuit Ratings (C/DC COIL) Standard Voltages 24 to 600VC / 24 to 500VDC 24 to 600 (C) / 24 to to 600 (C) / 24 to 240 (DC) Monofrequency Coils (V) 0.85 to 1.1 (C) 0.85 to 1.1 (C) 0.85 to 1.1 (C) Coil Operating Limits Pick-up (V) 0.4 to 0.76 (C/DC) 0.5 to 0.8 (C/DC) 0.5 to 0.8 (C) / 0.7 to 0.8 (DC) Drop-out (V) 0.25 to 0.65 (C) / 0.15 to 0.4 (DC) 0.2 to 0.6 (C) / 0.4 to to 0.6 (C) / 0.4 to 0.6 (DC) Coil Consumption Sealed (V) 4.0 to 7.2 (C) / 3.8 to 7.5 (DC) 9.2 to 12.5 (C) / 6.0 (DC) 16.5 to 25 (C) / 6.5 (DC) (Single Coils) Inrush (V) 70.0 (C) / 3.8 to 7.5 (DC) 115 (C) / 240 (DC) 295 (C) / 340 (DC) Heat Loss (W) Power Factor Closed Cos Φ Opened Cos Φ Operating Time Coil Energization-N.O. (ms) 35 to 45 (DC) 50 to 60 (DC) 50 to 60 (DC) Coil De-energization-N.O. (ms) 7 to 12 (DC) 55 to 60 (DC) 55 to 60 (DC) Overload H W D in mm in mm in mm IOL-40S/-80S IOL-105S IOL-150L-097-LK IOL-150L-112-LK IOL-150L-150-LK IOL-150L-215-LK IOL-180L IOL-300L ONLINE ORDERS FREESHIPPING SMLL PCKGES MIN LTL FREIGHT MIN. SEE INSIDE BCK COVER FOR MORE DETILS

11 98 Standard Contactors & Overloads (cont d) Contactor Specifications (cont d) Contactor ICxxx-112L ICxxx-150L ICxxx-180L ICxxx-250L ICxxx-300L Rated Insulation Voltage (V) UL/CS: 600, IEC/VDE 0660: 1000 Rated Impulse Voltage IEC (kv) Rated Operating Frequency (Hz) 25 to to to to to 400 Main Terminals IP00 IP00 IP00 IP00 IP00 Degree of Protection Coil Terminals IP20 IP20 IP20 IP20 IP20 uxiliary Terminals IP20 IP20 IP20 IP20 IP20 Vibration Resistance Contactor Open (g) (5 to 200Hz) Contactor Closed at Coil (g) Mechanical Endurance C Coil (Million ops) Electrical Endurance C-3 (Million ops) Shock Resistance (1/2 Sin Wave = 11ms) Terminal Capacity Overload IOL-40S/80S IOL-105S/150L IOL-300L Number of Poles 3 Rated Operation & Insulation Voltage IEC [V] UL; CS [V] 600 Rated Impulse Voltage [kv] 6 8 Tripping Class 10 Phase Failure Sensitivity Current mbient Temperature Contactor Open Contactor Closed at Coil Wires w/end Sleeve (WG) 1 x 300 or 2 x x 300 or 2 x x 300 or 2 x x 500 or 2 x x 500 or 2 x 300 Fine - Stranded w/sleeve (mm2) 2 x (25-70) 2 x (25-70) 2 x (50-120) 2 x (50-150) 2 x (50-150) Busbars (mm) 2 x (15x3) 2 x (15x3) 2 x (20x3) 2 x (30x5) 2 x (30x5) Screw Driver Philips #2 Philips #2 Philips #2 Philips #2 Philips #2 Tightening Torque (lb-in) Environmental Conditions mbient Temperature Direct YES NO lternating [Hz] Up to /60 Storage Operating Storage: -67 to 176 F (-55 to 80 C), Operating (IEC) -13 to 131 F (-25 to 55 C) Climatic Withstand ccording to IEC 68-2 Pollution Degree 3 Mounting Screw to panel Weight (lbs) Warranty Electronic Control Module Control Circuit Ratings (C/DC COIL) Standard Voltages (V) UL/CS: 600, IEC/VDE 0660: 1000 Coil Operating Limits YES -58 to 176 F (-50 to 80 C) -4 to 158 F (-20 to 70 C) Pollution Degree 3 Current Heat Loss [W] Weight [lb] / Shock Resistance (IEC ; 1/2 Sine Wave) [g/ms] 10/11 Standards IEC / , UL 508; CS C.22.2/14; VDE 0660/102 Power Terminals IP Rating IP10 IP00 Main Terminals Capacity Cross/Slotted Combination llen Head Slide Bar Stranded / Solid (UL/CS) 75 C, Cu Only [WG] /0 8-1/0 Tightening Torque [lb-in] ( ) 230 ( ) 1 year Monofrequency Coils (V) 24 to 500 Pick-up (V) 0.65 to 1.1 Drop-out (V) 0.70 to 0.85 Coil Consumption Sealed (V) 0.40 to 0.60 (Single Coils) Inrush (V) 40 to 85 Heat Loss (W) 50 to 75 Coil Consumption Sealed (V/W) 14.8 (C) / 2.4 (DC) 14.8 (C) / 2.4 (DC) 14.1 (C) / 2.4 (DC) 14.1 (C) / 2.5 (DC) 14.1 (C) / 2.5 (DC) Inrush (V/W) 213 (C) / 166 (DC) 213 (C) / 166 (DC) 214 (C) / 154 (DC) 229 (C) / 171 (DC) 229 (C) / 171 (DC) Heat Loss (W) 3.9 (C) 2.4 (DC) 3.9 (C) 2.4 (DC) 3.8 (C) /2.4 (DC) 3.7 (C) /2.5 (DC) 3.7 (C) /2.5 (DC) Overload Specifications

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors. Contactors E Line contactors. E Line contactors. xstart series contactors.3 xstart C series contactors.4 D Line contactors xstart series contactors xstart C series contactors D Line contactors X UTOMTION

More information

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4

Contactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4 Contactors E Line contactors xstart series contactors. E Line contactors Control relays XTRG....................................................... Contactors XTCG.........................................................

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Ambient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity.

Ambient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity. www.we.net Thermal Overload Relays - RW Series Rated for the new industry RW overload relays are an important part of WEG rane of products. s usual in WEG products, an extended operational service life

More information

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V)

Standard voltages. Alternating current (V) 50/60Hz Alternating current (V) Series CK Three and four pole contactors 150 to 825 (C3) 200 to 1250 (C1) Control circuit: lternating current up to 690V Direct current up to 500V Degree of protection IP00 (IPxx with accessories) CK07...CK13:

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

All round protection guaranteed

All round protection guaranteed s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Motor protective circuit breakers

Motor protective circuit breakers Motor protective circuit breakers Motor protective circuit breakers MSP Description The MSP0, MSP1 motor starter protectors are compact motor starter protectors for currents up to 52 A which operate according

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package The power of fusion. 87 88 89 899 90 908 9 9 9 9 97 97 977 98 98 989 999 There s a certain energy at Eaton. It s the

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC

Catalog Number 1NO-1NC 5 XTPAXSA11 5 XTPAXSAC -148 March 008 Accessories Auxiliary Contacts Side-Mount Auxiliary Contacts Can be fitted on the right side of manual motor protectors (XTPB, XTPR, XTPM) and manual transformer protectors (XTPT) and can

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1 Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series B Ex9BE3C0 Ex9BHC6 www.noarkus.com NORK Ex9 Series B NORK Miniature Circuit Breakers offer these advantages: highperformance, small size, exemplary

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Series CA6 Contactors

Series CA6 Contactors Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Manual motor starter magnetic only MO325

Manual motor starter magnetic only MO325 Data sheet Manual motor starter magnetic only MO325 Manual motor starters magnetic only are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 250 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88. Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring

More information

Miniature Industrial relay 8-16 A

Miniature Industrial relay 8-16 A 46 SЕRIES Miniature Industrial relay 8-16 utomation for blinds, grilles and shutters Elevators and lifts Shipyards Road / tunnel lighting Hoists and cranes Bottling plant Control panels Panels for electrical

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Leadership driven by innovation

Leadership driven by innovation s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

DPX Magnetic only

DPX Magnetic only 87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information