Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
|
|
- Thomas Kelly
- 6 years ago
- Views:
Transcription
1 Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current = 10 (I th ) Suitable for electronic devices (DIN 19240) Finger proof (VBG 4) ccessories 2- and 4-pole additional auxiliary contacts in different configurations pproved Standards Standard UL ICE VDE 0660 EN Guide No (US,C) NKCR, NKCR7 Ordering Information Model Number Legend LVSG 1. Mini Contactor Relays 7KN-##-##-##### ) Mini Contactor 2) R: Contactor Relay 3) Combination of NO / NC contacts 22: 2 NO 2 NC 31: 3 NO 1NC 40: 4 NO 0NC 4) Coil voltage (C operated) 24: C24V 50/60Hz 48: C48V 50Hz 110: C V 50Hz,C V 60Hz 230: C V 50Hz,C240V 60Hz 240: C230V-240V 50Hz 400: C V 50Hz,C440V 60Hz 415: C V 50Hz 550: C V 50Hz,C600V 60Hz Coil voltage (DC operated) 24D: DC24V 48D: DC48V 60D: DC60V 110D: DC110V 125D: DC125V 24VS: DC24V with diode 48VS: DC48V with diode 110VS: DC110V with diode 2. ux. Contact Modules for Mini Contactor Relays 73KN-##-##-# ) uxiliary Contact Modules 2) : for mini contactor relay 3) Combination of NO/NC contacts 11: 1 NO 1 NC 02: 0 NO 2 NC 22: 2 NO 2 NC 40: 4 NO 0 NC Mini Contactor Relays 4-pole J7KN-R H-7
2 System overview Mini Contactor Relays 4-pole C Operated Contacts Distinc. Number acc. to DIN EN Ratings Thermal Rated Current I th Type Pack Coil voltage 1) 24V 50/60Hz V 50Hz Weight C15 230V 400V 24 NO NC 230 pcs. kg/pc. 4-pole, With Screw Terminals 4-40E J7KN-R ,16 J7KN-R E J7KN-R ,16 J7KN-R E J7KN-R ,16 J7KN-R ) Other coil voltages see page 10 DC Solenoid Operated Contacts Distinc. Number acc. to Ratings C15 Thermal Rated Current Type Pack Weight NO NC DIN EN V 400V I th Coil voltage 24V DC 2,5W pcs. kg/pc. 4-pole, With Screw Terminals 4-40E J7KN-R-40 24D (-VS) 1) 10 0, E J7KN-R-31 24D (-VS) 1) 10 0, E J7KN-R-22 24D (-VS) 1) 10 0,19 1) VS = with diode uxiliary Contact Blocks for Contactor Relays J7KN-R Contacts Ratings C15 Thermal Rated Current Type Pack Weight NO NC 230V 400V I th pcs. kg/pc J73KN , J73KN , J73KN , J73KN ,04 H-8 Mini Contactor Relays 4-pole J7KN-R
3 System overview Mini Contactor Relays 4-pole C Operated Wiring Diagrams Distinc. Number acc. to DIN EN pole, With Screw Terminals uxiliary Contact Blocks Contactor Relay with uxiliary Contact Contacts suitable for Electronic Block Distinc. Number according to Circuits according to DIN for rated voltage 24V DC (test ratings 17V DC, 5m) Type NO NC DIN EN NO NC Positively guided contacts 40E J73KN E 5 1 Preferable combinations with J73KN E 4 2 distinctive letter E according to DIN EN J73KN E 8 0 J73KN E E J73KN Y 4 2 J73KN Y 3 3 J73KN Y 7 1 J73KN Y E J73KN Y 3 3 J73KN Y 2 4 J73KN Y 6 2 J73KN Y 4 4 DC Solenoid Operated Wiring Diagrams Distinc. Number acc. to DIN EN pole, With Screw Terminals uxiliary Contact Blocks Type NO NC Contactor Relay with uxiliary Contact Block Distinc. Number according to DIN EN NO NC 40E J73KN E 5 1 Preferable combinations with J73KN E 4 2 distinctive letter E according to DIN EN J73KN E 8 0 J73KN E E J73KN Y 4 2 J73KN Y 3 3 J73KN Y 7 1 J73KN Y E J73KN Y 3 3 J73KN Y 2 4 J73KN Y 6 2 J73KN Y 4 4 LVSG uxiliary Contact Blocks for Contactor Relays J7KN-R Wiring diagrams J73KN--11 J73KN--02 J73KN--40 J73KN--22 Contacts suitable for Electronic Circuits according to DIN for rated voltage 24V DC (test ratings 17V DC, 5m) Positively guided contacts Mini Contactor Relays 4-pole J7KN-R H-9
4 Specifications Coil Voltages Suffix Voltage Marking Rated Control Voltage U s to contactor type range for e.g. at the coil 50Hz 60Hz J7KN for 50Hz V for 60Hz V min max min max Suffix Voltage Marking Rated Control Voltage U s to contactor type range for e.g. at the coil 50Hz 60Hz for 50Hz J7KN V for 60Hz V min max min max Standard voltages in bold type letters. Coil not exchangeable H-10 Mini Contactor Relays 4-pole J7KN-R
5 Engineering data and Characteristics Mini Contactor Relays Data according to IEC , VDE 0660, EN uxiliary Contacts Type J7KN-R... J7KN-R...D J7KN-R...VS J73KN-... Rated insulation voltage U i V C 690 *1 690 *1 690 *1 690 *1 Thermal rated current I th to 690V mbient temperature 40 C C Power loss per pole at I th W Utilization category C15 Rated operational current I e V V V V V Utilization category DC13 Rated operational current I e 60V V V Maximum ambient temperature Operation open C -40 to +60 (+90) *2 enclosed C -40 to +40 Storage C -40 to +90 Short circuit protection short-circuit current 1k, contact welding not accepted max. fuse size gl (gg) Power consumption of coils C operated inrush V sealed V W LVSG DC operated inrush W sealed W Operation range of coils in multiples of control voltage U s Switching time at control voltage U s ±10% *3,*4 C operated make time ms release time ms arc duration ms DC operated make time ms release time ms arc duration ms Mini Contactor Relays 4-pole J7KN-R H-11
6 Mini Contactor Relays Data according to IEC , VDE 0660, EN uxiliary Contacts Type J7KN-R... J7KN-R...D J7KN-R...VS J73KN-... Cable cross-section all connectors solid mm² flexible mm² flexible with multicore cable end mm² Clamps per pole solid or stranded WG *1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): U imp = 8k Data for other conditions on request. *2) With reduced control voltage range 0.9 up to 1.0 x U s and with reduced thermal rated current I th to I e /C15 *3) Summary switching time = release time + arc duration *4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units). Mini Contactor Relays for North merica Data according to UL508 Main Contacts (culus) Type J7KN-R... J73KN-... Rated operational current "General Use" Rated operational power of three-phase motors 115V hp - - at 60Hz (3ph) 200V hp V hp V hp V hp - - Rated operational power of of C motors 115V hp - - at 60Hz (1ph) 200V hp V hp - - Fuses - - Suitable for use on a capability of delivering not more than rms - - V - - Rated voltage V C uxiliary Contacts (culus) heavy pilot duty C standard pilot duty DC Q600 Q600 H-12 Mini Contactor Relays 4-pole J7KN-R
7 Dimensions C and DC operated with screw terminals J7KN-R... uxiliary Contact Blocks J73KN-... LVSG Mini Contactor Relays 4-pole J7KN-R H-13
8 LL DIMENSIONS SHOWN RE IN MILLIMETERS. Cat. No. J507-E2-02 In the interest of product improvement, specifications are subject to change without notice. H-14 Mini Contactor Relays 4-pole J7KN-R
Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationApproved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories
Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationModel Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1
Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw
More informationContactors Motor-Starters D677E121
Contactors Motor-Starters D677E121 Index Page General 2 Approvals 3 Technical Information 5 Mounting Information 6 Mini Contactors 7 Mini Contactors 8 Interface Contactors 8 Mini Reversing Contactors 14
More informationCapacitor Switching Contactors Type K3...-A, K3...-K
Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and
More informationMotor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.
Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring
More informationIndex. Page. General 4 Approvals 5 Technical Information 9 Mounting Information 10
Index Page General 4 Approvals 5 Technical Information 9 Mounting Information 10 Micro Contactors 11 Micro Contactors 12 Micro Contactor Relays 14 Micro Reversing Contactors 18 Technical Information 20
More informationGeneral Catalogue. Quality made in D946E173
General Catalogue Quality made in D946E173 Index Page Contactors, Motor-Starter (D677E) 3 Micro Contactors 9 Mini Contactors 19 Contactor Relays 33 Contactors 39 Starters 85 D.O.L. Starters 105 Overload
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationContactors RAST 5 D778E131
Contactors RAST 5 D778E131 RAST 5 - exclusive for OEM-Partners 5 mm pitch connector system Advantages RAST 5 - Technology 59 mm Time saving installation Easy assembly without tools Tailor-made sockets,
More informationLow voltage switch gear
Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationMini Contactors CI 4-
Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they
More informationxxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads
22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationMAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-
MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4
More information3RT14 Contactors with 3 Main Contacts
3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e
More informationContactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660
Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,
More information44 SERIES. PCB/Plug-in relays from 6 to 10 A
44 PCB/Plug-in relays from 6 to 10 44 2 CO power relays with high separation between adjacent contacts Direct PCB or socket mount Type 44.52 -- 2 CO 6 (5 mm pin pitch) Type -- 2 CO 10 (5 mm pin pitch)
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Deliveryprogramme Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILER-31-G-C(110VDC) Articleno. 231831 CatalogNo. XTRMC10A31E0 Product range DILER Mini-contactors Application Contactor relays Description
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More informationContactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.
Contactors E Line contactors. E Line contactors. xstart series contactors.3 xstart C series contactors.4 D Line contactors xstart series contactors xstart C series contactors D Line contactors X UTOMTION
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More informationElectrical sector solutions E Line family. Industry leading design in a compact package
Electrical sector solutions E Line family Industry leading design in a compact package The power of fusion. 87 88 89 899 90 908 9 9 9 9 97 97 977 98 98 989 999 There s a certain energy at Eaton. It s the
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Deliveryprogram Contactorrelay,2N/O+2N/C,DCcurrent Partno. DILER-22-G(220VDC) Articleno. 010091 CatalogNo. XTRM10A22BD Product range DILER Mini-contactors Application Contactor relays Description with
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationContactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30
Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable
More informationNSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals
NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low
More informationModular contactor for installation into distribution boards
Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,
More informationContactors. 1.1 E Line contactors Control relays XTRG... 1 Contactors XTCG... 4
Contactors E Line contactors xstart series contactors. E Line contactors Control relays XTRG....................................................... Contactors XTCG.........................................................
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationApprobationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking
Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description
More informationModular Contactors and Switches D681E121
Modular Contactors and Switches D681E121 Modular Contactors and Switches Modular Contactors 2, 3 Aux. contact block 3 Accessories 3 Day Night Reloading Contactors 4 Safety Switches 5 Main Switches Emergency
More informationMotors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line
Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors
More informationSeries CA6 Contactors
Series C6 Contactors classic contactor for demanding applications from 75 to 600HP (@460V) - 100 to 700HP (@ 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationElectrical sector solutions E Line family. Industry leading design in a compact package
Electrical sector solutions E Line family Industry leading design in a compact package Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability
More information4 - Miniature controls
Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationA Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.
C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,
More informationPage 2-4 Page 2-8. Page Page 2-12
Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V
More informationGeneral + Definite Purpose Contactors
General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3
More informationTechnical Information
Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage
More informationMS25, MST25, MS20, MST20
Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers
More information2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current
0 Series - General purpose relays - 0 Features 0. 0. Plug-in mount 0 General purpose relay & pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils UL Listing (certain relay/socket
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More informationSystem pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489
Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationManual Motor Protectors
88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)
More informationProduct range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102
Overloadrelay,10-16A,1N/O+1N/C Partno. ZB12-16 Articleno. 290168 CatalogNo. XTOB016BC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Frame size ZB12 Phase-failure sensitivity IEC/EN 60947,
More informationMiniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil
2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal
More informationI r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.
DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB
More informationGeneral purpose relays 7-10 A
55 SЕRIES General purpose relays 7-10 utomation for blinds, grilles and shutters Control and management of electric power Shipyards Road / tunnel lighting Hoists and cranes Circuit breakers and switches
More informationPluggable interface relays RT, PT and MT range
Content Pluggable interface relays RT, PT, MT Benefits and advantages, approvals... 190 Ordering details... 191 Technical data... 194 Circuit diagrams... 19 Dimensional drawings... 19 189 Benefits and
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationLow Voltage Switches. Switches Motorized change-over switches OTM _C
Low Voltage Switches Switches Motorized change-over switches OTM...12_C II I OTM 12_C Improves your permance OTM II I 0 OFF ON I 0 OFF II I ON I ssembly made easy Bridging bars quick wiring Tunnel terminals
More informationSeries CA5 Contactors
Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower
More informationCI-TI TM Contactors and Motor Starters Contactors CI 6-50
Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9
More informationStandard voltages. Alternating current (V) 50/60Hz Alternating current (V)
Series CK Three and four pole contactors 150 to 825 (C3) 200 to 1250 (C1) Control circuit: lternating current up to 690V Direct current up to 500V Degree of protection IP00 (IPxx with accessories) CK07...CK13:
More informationUL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated
11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF
More informationMotorized switch-disconnectors OTM 40 to 125 Amperes
Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution
More information5 mm contact pin pitch PCB or 95 series sockets
1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket
More informationGeneral Purpose Relays Accessories. Accessories Industrial Power Relay RT
Industrial Power Relay RT n For Industrial Power Relay RT pinnings 3.5 mm / 5 mm; n New retainer clip with ejection function n Easy replacement of relays on a densely packed DIN rail n No reduction of
More informationSwitches Unlimited Phone: * Fax:
For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationGeneral purpose relays 6-10 A
60 SЕRIES General purpose relays 6-10 Shipyards Hoists and cranes Road / tunnel lighting Burners, boilers and furnaces Wood-processing machines Panels for electrical distribution Control panels Control
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More information60 Series - General purpose relays 6-10 A. Features SERIES
60 Series - General purpose relays 6-10 60 SERIES Features 60.12 60.13 Plug-in mount 10 General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils
More informationDATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer
DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationSIRIUS. Answers for industry.
s SIRIUS Datasheet 01 nswers for industry. Introduction Contactors and Contactor ssemblies SIRIUS RW Soft Starter Protection Equipment Load Feeders and Motor Starters for Use in the Control Cabinet Monitoring
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationMiniaturized limit switches
Miniaturized limit switches Selection diagram Actuators 04 0 06 Thermoplastic Bodies M3 Contact blocks NONC 1NO+1NC snap action Cable entry With screw 290 GENERAL CATALOGUE miniaturized limit switches
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been
More informationTechnical Information
Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationOverloadrelay,10-16A,1N/O+1N/C. Articleno
Overloadrelay,10-16A,1N/O+1N/C Partno. ZB32-16 Articleno. 278452 CatalogNo. XTOB016CC1 Deliveryprogramme Product range Overload relay ZB up to 150 A Product range Accessories Accessories Overload relays
More informationSafety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries
Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,
More informationCharacteristics TeSys contactors 0 TeSys k contactors and reversing contactors
90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationPower Contactor with Mirror Contacts
LLAME SN COSTO Force-Guided Relays Power Contactor with Mirror Contacts Contents Selection Guide 2 Force-Guided Relays G7SA G7S- -E 3 8 Power Contactor with Mirror Contacts J7KNA-AR G7Z 11 15 1 LLAME SN
More informationGeneral_technical_data Series
Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The
More information55 Series - Miniature General Purpose Relays 5-10 A
Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:
More informationPage 2-4 Page 2-8. Page Page 2-13
Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP
More informationBulletin 193-T1 Bimetallic Overload Relays
Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode
More informationAdd-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...
Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles
More informationDeliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection
Deliveryprogramme Overloadrelay,6-9A,1N/O+1N/C Partno. ZE-9 Articleno. 014708 CatalogNo. XTOM009AC1 Product range ZE overload relays for mini contactor relays Phase-failure sensitivity IEC/EN 60947, VDE
More informationMiniature Industrial relay 8-16 A
46 SЕRIES Miniature Industrial relay 8-16 utomation for blinds, grilles and shutters Elevators and lifts Shipyards Road / tunnel lighting Hoists and cranes Bottling plant Control panels Panels for electrical
More informationAE 9... AE 40 Contactors NE... Contactor Relays
Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal
More informationPre wired limit switches
Pre wired limit switches Selection diagram Actuators A B B 9 BL Thermoplastic Bodies E7 I s NO+NC snap action NO+NC slow action Cable entry 4 or 5 pole PVC sheath cable (standard) M connector AMP connector
More information