Series CA6 Contactors

Size: px
Start display at page:

Download "Series CA6 Contactors"

Transcription

1 Series C6 Contactors classic contactor for demanding applications from 75 to 600HP to 700HP 575V) This series is being replaced by the C9 Series of contactors Sprecher + Schuh s C6 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this middle horsepower range. On average these contactors are 50% smaller than traditional contactors in this size class. broad selection for middle horsepower applications The C6 range consists of nine contactors in three frame sizes covering motors from 75 to 600HP at 460V and from 100 to 700HP at 575V. This line is ideally suited for demanding applications such as steel mills, rock quarries, mines or for any middle horsepower application where a sturdy, durable contactor is needed. Rugged and reliable C6 contactors conform to UL508, IEC and can be operated at rated voltages up to 600V (UL) and 1000V (IEC). High thermal and switching capacities guarantee reliable operation and long life. C6 contactors are listed in CS Certified Elevator Equipment for heavy duty use in elevators, refrigerators and heating installations in Canada. rc quenching extends contact life ll C6 contactors are designed with sophisticated arc quenching techniques that extinguish damaging breaking arcs quickly. This is accomplished by guiding the arc away from the contacts and into arc chambers which are built-in to every C6 cover. Safety first C6 arc chambers are completely enclosed (without arc exhaust vents), offering the best protection against hot arcing gases. large safety distance in front of the contactor is unnecessary. C6 contactors are also designed so that operation is impossible if the arc chambers are removed. Conversely, once the contactor is energized, the arc chambers cannot be removed. When used with terminal covers or HB Touch-Safe Lugs, C6 contactors meet international standards for touch-safe design. 120mm ( 4 3/4 ) mm ( 4 3/4 ) mm ( 6 3/32 ) mm ( 8 15/32 )

2 Electronic coils offer many advantages Behind the attractive outward appearance of the C6 contactor are advanced engineering solutions that offer convenience and savings. The entire line can be equipped with an electronically controlled coil that reduces pick-up currents by 60% on average. Holding current is also reduced Comparison of pick-up and holding current [V] Conventional Coil pick-up holding Electronic Coil Other advantages of the C6 electronic coil include: Direct connection to a PLC Overvoltage protection and suppression circuits (eliminating interference from the coil) are standard C6 EI electronic coils offer many unique advantages over conventional types Smooth, even operation over the entire voltage range minimizes the possibility of contact bounce No safeguards are necessary to bridge brief supply interruptions Precisely defined pick-up and dropout voltages, eliminate the possibility of chattering Electronic coils operate over a much broader voltage range, providing flexibility in applications and lower costs due to reduced inventory Two user-selectable modes C6 contactors with electronic coils operate in either the E mode for normal operation or the EI mode for interfacing directly with a Programmable Logic Controller (PLC) or other low level signal source ( VDC). The coil is set in the E mode from the factory, offering all of the functions and advantages of an electronic coil with the exception of electronic interface. n orange jumper located on the bottom of the contactor can be quickly changed if interface from a PLC is desired. detailed technical explanation of EI coils along with connection diagrams can be found in the Technical Section. Jumper set in E mode (factory default) Jumper set in EI mode (user selectable) The entire C6 line is modularly designed for easy inspection, coil change and contact replacement. Maintenance can be performed from the front so that mounting requires no additional space. Even with the installation of mechanical interlocks and auxiliary contact blocks, the units can be flush mounted side by side, saving panel space EI Contactor EI Contactor 3 Main Terminal Set 4 Lug set 5 Mechanical Interlock 6 ux. Contact Block 7 ux. Contact Block 8 ux. Contact Block 9 ux. Contact Block 10 Terminal Cover 11 Surge Suppressor 1 1 C6 contactors utilize modular design techniques that speed installation, reduce panel space and facilitate maintenance

3 Non-Reversing, Three Pole Contactors With C Coil, Series C6 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3 ) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price / /82 80 ➍ / ➍ 135 ➍ ~ EI EI EI Contactors - C Coil Three Pole - Series C6 140-EI contactor / ~ EI / ~ ~ EI / ~ ~ EI / ~ ~ EI ~ ~ EI ~ ~ ~ EI EI contactor Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. Coil Codes ➋ C Coil Code 115 /140 /180 Voltage Range 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B V 240V V 277V V 440V V 480V V 575V 115-EI EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 ➎ 24V V 220W V 460W V 630-EI EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz V ➏ 208W V 240W V ➏ V V C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor with Electronic Interface coil. ➋ Other voltages available, see page ➌ For CS Elevator duty rating, consult Technical Information on page 139. ➍ Ratings are higher for contactors with electronic coil: 140-EI EI V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➎ 24 VC Coil is not available for 420-EI. ➏ Coil is rated C/DC. 122 Discount Schedule B7

4 Non-Reversing, Three Pole Contactors With DC Coil, Series C6 (Open type only) ➊➌ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price / /82 80 ➍ / ➍ 135 ➍ ~ L EI L EI L EI / ~ EI Contactors - DC Coil Three Pole - Series C6 140-EI contactor with DC coil / ~ ~ EI / ~ ~ EI / ~ ~ EI ~ ~ EI ~ ~ ~ EI Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. 420-EI contactor with DC coil Coil Codes ➋ 115 / 140 / 180 DC Voltage Range Coil Code 24D 24V 110D 110V 220D 220V Note: Conventional DC coils have high current pick-up winding and low current seal-in winding wired in parallel. The pick-up winding is taken out of the circuit after the armature pulls in. Price includes two winding coil and an L11 block including one NC late break auxiliary contact mounted on the right side. See page 149 for functional schematic. 115-El EI ➊ DC Coil Code Voltage Range 24D ➎ 24V 120D V 220D V EI ➊ DC Coil Code Voltage Range V ➏ 240W V ➏ C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code See Coil Codes on this page ➊ -EI designates contactor with Electronic Interface coil. ➋ Other voltages available, see page ➌ For CS Elevator duty rating, consult Technical Information on page 139. ➍ Ratings are higher for contactors with electronic coil: 140-EI EI V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➎ 24V DC Coil not available for 420-EI. Customers selecting 24V DC Coils should consider the EI functionality of the C6 (see page 148). ➏ Coil is rated C/DC. Discount Schedule B7 123

5 Reversing, Three Pole Contactors With C Coil, Series C6 (Open type only) ➏ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC Catalog Number ➊➌ Price / /82 80 ➐ / ➐ 135 ➐ ~ CU CU6-115-EI-22- CU CU6-140-EI-22- CU CU6-180-EI-22- Contactors, C Coil Reversing Three Pole - Series CU / ~ CU6-210-EI / ~ ~ CU6-250-EI / ~ ~ CU6-300-EI / ~ ~ CU6-420-EI ~ ~ CU6-630-EI ~ ~ ~ CU6-860-EI CU6-180 reversing contactor Includes: Mechanical and electrical Interlock ➍ Reversing power wiring (using Power Wiring Kit Cat.# VL[T]) ➊ Mounting plate Control wiring available; see footnote ➋ Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. Coil Codes ➋ C Coil Code 115 / Voltage Range 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B V 240V V 277V V 440V V 480V V 575V ➊ For -LW Option Deduct the following from List Price CU CU ➋ For -CW Option dd the following to List Price ll CU6 20 Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code 115-EI EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 ➑ 24V V 220W V 460W V 630-EI EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz V ➒ 208W V 240W V ➒ V V See Coil Codes on this page C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU becomes CU LW. Control wiring is not included. ➋ For control wiring, add suffix -CW to catalog number. For example: CU becomes CU CW. ➌ -EI designates contactor with Electronic Interface coil. ➍ One NC auxiliary contact on each contactor is used for electrical interlocking. ➎ Other voltages available, see page ➏ For CS Elevator duty rating, consult Technical Information on page 139. ➐ Ratings are higher for contactors with electronic coil: 140-EI EI V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➑ 24 VC Coil is not available for 420-EI. ➒ Coil is rated C/DC. 124 Discount Schedule B7

6 Reversing, Three Pole Contactors With DC Coil, Series C6 (Open type only) ➏ Ratings for Switching C Motors (C2 / C3) uxiliary Open Type I e [] kw (50 Hz) UL/CS HP (60 Hz) Contacts per 1 Ø 3 Ø Contactor 400V/ Catalog C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V NO NC➍ Number ➊➌➎ / /82 80 ➐ / ➐ 135 ➐ ~ CU6-115-L42- CU6-115-EI-22- CU6-140-L42- CU6-140-EI-22- CU6-180-L42- CU6-180-EI / ~ CU6-210-EI / ~ ~ CU6-250-EI / ~ ~ CU6-300-EI Contactors, DC Coil Reversing Price / ~ ~ CU6-420-EI ~ ~ CU6-630-EI ~ ~ ~ CU6-860-EI Three Pole - Series CU6 CU6-180 reversing contactor with DC coil Includes: DC operating mechanism Mechanical and electrical Interlock ➍ Reversing power wiring (using Power Wiring Kit Cat.# VL[T]) ➊ Mounting plate Control wiring available; see footnote ➋ Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. Coil Codes ➎ 115 / 140 / 180 DC Coil Code Voltage Range 24D 24V 110D 110V 220D 220V Note: Conventional DC coils have high current pick-up winding and low current seal-in winding wired in parallel. The pick-up winding is taken out of the circuit after the armature pulls in. Price includes two winding coil and an L11 block including one NC late break auxiliary contact mounted on the right side. See page 149 for functional Ordering Instructions Specify Catalog Number Replace ( ) with Coil Code 115-EI EI ➊➑ DC Coil Code Voltage Range 24D ➏ 24V 120D V 220D V EI ➊➑ DC Coil Code Voltage Range V ➒ 240W V ➒ schematic. ➊ For -LW Option Deduct the following from List Price CU CU ➋ For -CW Option dd the following to List Price ll CU6 20 See Coil Codes on this page C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil ➊ For Reversing Contactors without power wiring add suffix -LW to catalog number. For example: CU becomes CU LW. Control wiring is not included. ➋ For control wiring, add suffix -CW to catalog number. For example: CU becomes CU CW. ➌ -EI designates contactor with Electronic Interface coil. ➍ One NC auxiliary contact on each contactor is used for electrical interlocking. ➎ Other voltages available, see page ➏ For CS Elevator duty rating, consult Technical Information on page 139. ➐ Ratings are higher for contactors with electronic coil: 140-EI EI V = 98 kw 500V = 126 kw 690V = 135 kw 690V = 176 kw ➑ 24V DC Coil not available for 420-EI. Customers selecting 24V DC Coils should consider the EI functionality of the C6 (see page 148). ➒ Coil is rated C/DC Discount Schedule B7 125

7 Special Use Contactors - C Coil NEM Labeled Contactors - Series CN7 / CN6 Non-Reversing, Three Pole NEM Labeled Contactors with C Coil ➊➌ NEM Size 1Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 115V 230V 200V 230V 460V 575V NO NC Catalog Number 00 1/ /2 1-1/ CN CN /2 7-1/ CN / CN / CN ~ ~ Price See page 42 CN CN6-180-EI ~ ~ CN6-300-EI CN6 NEM labeled contactor (C) pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See pages for coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See page 132 (C[N]6). Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. CN6 C Coil Codes Conventional Coils ➋ CN6-180 C Coil Voltage Range Code 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B V 240V V 277V V-400V 440V V 480V V 575V CN6 C Coil Codes EI Electronic Coils ➋➌ CN6-180-EI EI C Coil Voltage Range Code 50 Hz / 60 Hz 24 24V V 220W V 460W V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 154 for CN6 dimensions. ➋ Other voltages available, see pages for CN6 coils. ➌ -EI designates contactor with Electronic Interface coil. 126 Discount Schedule B8

8 Special Use Contactors - DC Coil NEM Labeled Contactors - Series CN7 / CN6 Non-Reversing, Three Pole NEM Labeled Contactors with DC Coil ➊ NEM Size 1Ø Maximum Horsepower 3Ø Standard uxiliary Contacts 115V 230V 200V 230V 460V 575V NO NC Catalog Number 00 1/ /2 1-1/ CN7-12E-10- ➎ CN7-16E-10- ➎ /2 7-1/ CN7-37E-10- ➎ / CN7-43E-10- ➎ 3 7-1/ CN7-85D-10- Price See page 43 CN6 NEM labeled contactor 4 ~ ~ CN6-180-L22- ➍ 2953 CN6-180-EI-11- ➌➍ ~ ~ CN6-300-EI-11- ➌➍ 6529 pplication Notes NEM contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-2. These contactors are labeled for applications that require compliance with NEM standards. Sizes are based on standard NEM classifications. Easy coil change and contact replacement. See pages for coils and contacts. Snap-on auxiliary contact blocks available in many configurations. See page 132. Note: C6 open-type contactors include terminal bolts. If lugs are required, see page 129 for ordering information. CN6 DC Coil Codes Conventional Coils ➋➍ CN6-180-L22 DC Coil Code Voltage Range 24D 24V CN6 DC Coil Codes EI Electronic Coils ➋➍ CN6-180-EI EI DC Coil Code Voltage Range 24D 24V Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ Refer to page 154 for CN6 dimensions. ➋ Other voltages available, see pages for CN6 coils. ➌ -EI designates contactor with Electronic Interface coil. ➍ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see pages ). Discount Schedule B8 127

9 Hydraulic Elevator Wye Delta, with C Coils (Two Contactor Type ➊➋➎) Maximum Horsepower Three Phase Industrial pplication ➎ CS Elevator Duty ➏ uxiliary Contacts per Contactor Open Type 200V 230V 460V 575V NO NC ➌ Catalog No. Price C6Y LW C6Y2-115-EI-22- -LW C6Y LW C6Y2-140-EI-22- -LW C6Y LW C6Y2-180-EI-22- -LW 3404 HP Selection Larger sizes are possible. Contact your Sprecher + Schuh representative. C6 EI coils are electronically controlled coils with the following characteristics: bility to connect directly to a low level signal source such as a PLC (13-30 VDC at 15m max.) Very low pull-in and holding current for contactors in this size class Threshold voltages for pull-in and drop-out are very precisely defined, eliminating chattering Supply voltage dips are bridged without extra equipment EI coils cover a much wider voltage range with only one coil Reduced Voltage Contactors Wye Delta - Series C6Y2 C6Y2-115 Wye-Delta contactor Includes: Mechanical and electrical Interlocks ➌ Mounting plate Optional: Power wiring available but not included (see page 130) ➊➐ VYU 115 Coil Codes ➍ C Coil Code Voltage Range 50 Hz 60 Hz 24 ~ 24V 120B 110V 120V 208 ~ 208V 240B V 240V V 277V V 440V V 480V V 575V 115-EI 180-EI ➊ C Coil Code Voltage Range 50 Hz / 60 Hz 24 24V V 220W V 440W V ➊ For -PW Option dd the following to List Price C6Y M 180-VLHB S Ordering Instructions Specify Catalog Number Replace (Q) with Coil Code See Coil Codes on this page. ➊ For Contactors with power wiring add suffix -PW to catalog number. For example: C6Y LW becomes C6Y PW. Control wiring is not included. ➋ -EI designates contactor with Electronic Interface coil. ➌ One NC auxiliary contact on each contactor is used for electrical interlocking. ➍ Other voltages available, see page ➎ HP selection based on UL508 for Industrial pplications. ➏ HP selection based on CS Elevator Duty Ratings. ➐ See typical Wye-Delta Wiring Diagram on page C Discount Schedule B7

10 ccessories - Field Installable Main Lugs and Lug ccessories Lug or ccessory Connection Description Catalog Number Price Multiple conductors (flat or round) fit in each terminal on HB Main Terminal Sets (top view) ccommodation for dual connections to each pole ccepts flat or round conductors Touch safe to IP20 according to IEC Eliminates need for Terminal Shields Main Terminal Sets (catalog #: HB ) are specifically designed for connecting line and load to all three poles on C6 contactors. Each touch safe terminal set contains three built-in terminals capable of carrying two round conductors or multiple flat conductors. Main Terminal Sets add a clean finished appearance to C6 contactors Main Terminal Set, Dual Conductor, Touch Safe (price as complete set, containing 2 blocks, 6 lugs) For 115(-EI); 140(-EI); 180(-EI) For 210-EI to 420-EI HB2 HB Screw Type Lugs - Single connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For 115(-EI); 140(-EI); 180(-EI) For 210-EI to 420-EI L180 L Screw Type Lugs - ccommodation for dual connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For 630-EI L Screw Type Lugs - ccommodation for dual connections to each pole ccepts round conductors only Copper construction (set of 3 - two sets required to wire line and load sides) For 860-EI L (Typical) Control Wire Terminal ➊ 2 x 2.5mm 2 For 115(-EI); 140(-EI); 180(-EI) T For 210-EI to 420-EI T ➊ The IP2X lug rating will no longer apply if used with HB_ main terminal set. See Page 145 for terminal wire ranges. Discount Schedule B7 129

11 ccessories - Field Installable Power Wiring Connection Kits Connection Kits pplication Used with contactor... Use with Lug... Catalog Number Price 180-VLHB Reversing Line Side Wye-Delta Line Side Connects L1-L1 L2-L2 L3-L3 115(-EI) to 180(-EI) 115(-EI) to 180(-EI) 210-EI to 420-EI 630-EI to 860-EI L180 HB2 HB3 420-HU L420 L630 L VLHB VLHB VL (-EI) to 180(-EI) L VT VT Reversing Load Side Connect T1-T3 T2-T2 T3-T1 115(-EI) to 180(-EI) HB2 180-VTHB EI to 420-EI HB3 420-VTHB EI to 420-EI 420-HU L VT EI to 860-EI L VT VYU Wye-Delta Shorting Bar 115(-EI) to 180(-EI) 210-EI to 420-EI N/ 180-VYU 420-VYU EI to 860-EI N/ 860-VYU Wye-Delta (2M to S jumper) Connects 2M contactor 210-EI to 420-EI... to S contactor C6140(-EI ) to 180(-EI) HB3 420-VYHB VT Connects 2M contactor 210-EI to 420-EI... to S contactor 210-EI to 420-EI 420-HU L VT Discount Schedule B7

12 ccessories - Field Installable Lug ccessories and Backpans ccessory Description Main Terminal Cover - ➊ C6 touch protection Line or load (price each) IP20; IEC60529 & DIN protection For use with contactor... Catalog Number Price 115(-EI) to 180(-EI) 210-EI to 420-EI 630-EI to 860-EI 630-EI to 860-EI 630-EI to 860-EI 630-EI to 860-EI TC180 TC420 TC860 TCS860 ➋ TCR860 ➌ TCE860 ➍ Mounting Plates 1 contactor & 1 O/L relay (cross- The-Line) 115(-EI)...180(-EI) 210-EI EI 630-EI EI MS180 MS420 MS contactors & 2 O/L relays (Reversing or Multispeed) 115(-EI)...180(-EI) 210-EI EI 630-EI EI MU180 MU420 MU contactors, 2 O/L relays & 1 relay/ timer (Wye-delta) For 115(-EI) to 180(-EI) For 210-EI to 420-EI 630-EI to 860-EI MY180 MY420 MY ➊ Terminal Covers not necessary when using Main Terminal Sets (HB ) which are insulated. ➋ DOL starter/relay terminal covers ➌ Reversing starter/relay terminal cover ➍ Line-side panel relay and reversing terminal cover Discount Schedule B7 131

13 ccessories - Field Installable uxiliary Contact Blocks, 2 Pole uxiliary Contact Blocks NO NC Contact rrangement Mounting Position Catalog Number Price Inside left or right S Outside left or right S NOTE: Up to four auxiliary contact blocks (8 poles) may be mounted on the side of the C6 contactor. One auxiliary contact block (1 NO + 1 NC) is mounted at the factory. New style contactors with conventional DC coils have an -L11 mounted to right side and an -11 mounted to left side at the factory LB Inside left or right S1-L Inside left or right S Inside left position (S1) Inside right position (S1) Outside left or right S Outside left position (S2) Outside right position (S2) Form C Electronic Compatible Inside left or right S1-B11 ➊ Miscellaneous ccessories ccessory Description For use with... Catalog Number Price Mechanical Interlock- No built-in auxiliaries Interlocks C6 contactors CM6-D CM6-D00 Interlocks C6 to C contactors CM6-C Mechanical / Electrical Interlock - Two built-in N.C. auxiliaries CM6-D02 Interlocks C6 contactors CM6-D ➊ Electronic compatible auxiliary contacts function through the use of an internal micro-switch and have the following ratings: IEC 947 Data: C-1 250V 0.1 C-15/DC-13 min V 1 100m UL 508, CS 22.2 Data: 250VC max. 0.1 Minimum Switching 17V 5m 132 Discount Schedule B7

14 ccessories - Field Installable Miscellaneous ccessories ccessory Description For use with... Catalog Number Price Surge Suppressor - Limits voltage spikes when switching off coil. ttaches to all C6 contactors. RC Link: 21-48V 50Hz V 60Hz V 50 Hz / V 60 Hz V 50Hz / V 60Hz V 50Hz / V 60Hz Varistor Link: 12-55V 50/60Hz V 50/60Hz V 50/60Hz V 50/60Hz Varistor Link: 24-28V C/DC 48-72V DC 43-65V 50/60Hz /60 Hz V 50/60Hz Conventional C Coils Conventional C Coils Electronic (-EI) Coils ➊ CRC6-48 CRC6-110 CRC6-240 CRC6-550 CRV6-55 CRV6-136 CRV6-277 CRV6-575 CRV6-40 CRV6-55 CRV6-75 CRV6-550 CRV Marking Systems Component Description Pkg. Qty. Catalog Number Price Each Label Sheet - 1 sheet with 105 self-adhesive paper labels each, 6 x17mm 1 C7-FMS Marking Tag Sheet - 1 sheet with 160 perforated paper labels each, 6 x 17mm. To be used with transparent cover Transparent Cover - To be used with Marking Tag Sheets 1 C7-FMP 100 ➋ C7-FMC See page 54 Tag Carrier - For marking with marker cards and tags. See page N35 for complete listing of available cards and tabs. 100 ➋ C7-FM2 ➊ EI contactors are supplied with factory installed integrated surge protection (see page 135). ➋ Minimum order quantity is one package of 100. Price each x 100 = total price. Discount Schedule B7 133

15 Renewal Coils -.C., Conventional Coil ➊ C Control Voltages Conventional Coil C Coil Codes For use with contactor... 95, , 140 C(N)6-180 Optional RC Module ➋ Optional Varistor Module ➋ 50 Hz 60 Hz 50/60 Hz Catalog No. Catalog No. Catalog No. 24V ~ ~ 24 TG407 CRC6-48 CRV6-55 ~ 24V ~ 24 TG013 CRC6-48 CRV V 36V ~ ~ TG481 CRC6-48 CRV V 48V ~ 48 TG482 CRC6-48 CRV V 55V ~ 48 TG414 CRC6-48 CRV V 120V ~ 120B TG473 CRC6-110 CRV6-136 ~ 208V ~ 208 TG049 CRC6-240 CRV V 240V ~ 240B TG441 CRC6-240 CRV V 277V ~ 277 TG480 CRC6-240 CRV V-400V 440V ~ 380 TG071 CRC6-880 CRV V 480V ~ 480 TG475 CRC6-550 CRV V 508V ~ ~ TG478 CRC6-550 CRV V 575V ~ 575 TG479 CRC6-550 CRV V 600V ~ 600 TG476 CRC6-550 CRV6-575 Price 178 See page 133 for pricing C6.C. Coil (typical) Renewal Coils Renewal Coils - D.C., Conventional Two-Winding Coil ➊➌ DC Control Voltages Conventional Coil DC Coil codes For use with contactor , 140 C(N)6-180 Catalog No. Factory Integrated Varistor built into coil 12V 12D TG708 Yes 24V 24D TG714 Yes 48V 48D TG724 Yes 110V 110D TG733 Yes 125V 125D TG737 Yes 220V 220D TG761 Yes 240V ~ TG750 Yes 250V 250D TG751 Yes Price Items in grey are obsolete. ➊ Other coil voltages available. Contact your Sprecher + Schuh representative for information. ➋ Not factory installed, must be ordered separately. ➌ For conventional DC coils, the pickup winding must be connected to a NC late-break auxiliary contact. (See page 149) 134 Discount Schedule B6

16 Renewal Coils -.C., -EI Electronic Coil ➊➌➎ C Control Voltages EI Coil C Coil Codes ➋ 95-EI 110-EI 115-EI 140-EI 180-EI CN6-180-EI 210-EI 250-EI For use with contactor EI CN6-300-EI 420-EI 630-EI 860-EI EI Coil Suppressor Info Factory Integrated Suppressor on Coil Circuit Board ➌ Factory Installed External Suppressor Module ➌ 60 Hz 50/60 Hz Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. ~ 24V 24 TGE855 TGE855 ~ ~ No CRV6-40 ~ 42-64V 48 TGE864 TGE864 ~ ~ No CRV6-75 ~ V 120 TGE865 TGE865 THE865 ~ Yes ~ ~ V 220W TGE866 TGE866 THE866 ~ Yes ➍ ~ V 460W TGE867 TGE867 THE867 ➑ ~ Yes RC 100N ➎ ~ V 120 ~ ~ ~ TJE865 ➏ Yes ~ ~ V 208W ~ ~ ~ TJE878 Yes ~ ~ V 240W ~ ~ ~ TJE879 ➏ Yes ~ ~ 277V 277 ~ ~ ~ TJE880 Yes ~ ~ V 380 ~ ~ ~ TJE867 Yes ~ ~ V 480 ~ ~ ~ TJE868 Yes ~ Price Renewal Parts C6.C. -EI coil (typical) Renewal Coils - D.C., -EI Electronic Coil ➊➌➍ DC Control Voltage DC Coil Codes 95-EI 110-EI 115-EI 140-EI 180-EI CN6-180-EI 210-EI 250-EI For use with contactor EI CN6-300-EI 420-EI 630-EI 860-EI EI Coil Suppressor Info Factory Integrated Suppressor on Coil Circuit Board ➌ Factory Installed External Suppressor Module ➌ EI Coil Catalog No. Catalog No. Catalog No. Catalog No. Catalog No. 24V ➐ 24D TGE708 TGE708 ~ ~ No CRV V 48D TGE779 TGE779 ~ ~ No CRV V 120D TGE780 TGE780 THE780 ~ Yes ~ V 220D TGE781 TGE781 THE781 ~ Yes ~ ~ ~ ~ TJE865 ➏ Yes ~ V 240W ~ ~ ~ TJE879 ➏ Yes ~ Price Items in grey are obsolete. ➊ Other coil voltages available. Contact your Sprecher + Schuh representative for more information. ➋ Coil Codes in bold letters and shaded indicate coils that are standard stocked items. ➌ Factory external suppressor module provided where shown, included with replacement coil. ➍ Factory integrated suppressor is overvoltage category III, for optional category IV, e.g. lightning protection, a CRV6-550 module can be added. ➎ Special capacitor module supplied on 420 only, not shown in catalog. ➏ Coil is rated C / DC. ➐ Customers with 24VDC applications should strongly consider using the EI functionality of the C6 (see page 148). ➑ Contactor manufactured with V coils can not be interchanged with any other coils because of the circuit board built into the base of the 420. Discount Schedule B6 135

17 Main Contact - 3 Per Set (up to 420) Main Contacts (typical) For use with... Catalog Number Standard Terminal Hardware (screw & washer) ➊ Price/ Set 95 C EI CE C EI CE C EI CE C EI CE C(N)6-180 C C(N)6-180-EI CE EI CE EI CE C(N)6-300-EI CE EI CE Items in grey are obsolete and have limited availability. Renewal Parts Main Contact & rc Chute - Complete Set (630 and 860) Complete set of three each Main Contact, rc Chute and hardware For use with... Catalog Number Price/ Set 630-EI CE-630 ➍ EI CE-860 ➍ 3980 Terminal Hardware Fits Contactor... Screw Type Catalog Number Price Each 95 & 110 M6 HF (-EI), 140(-EI) & C(N)6-180(-EI) 210-EI, 250-EI, C(N)6-300-EI & 420-EI M8 HF M10 HF rc Chutes ➋➌ rc Chutes (typical) 630-EI to 860-EI M12 HF Items in grey are obsolete and have limited availability. For use with... Catalog Number Price/ Set EI E EI E EI E EI E C(N) C(N)6-180-EI E EI E EI E C(N)6-300-EI E EI E Items in grey are obsolete and have limited availability. ➊ Set of six (6). Priced per set. ➋ One (1) required per contactor. ➌ W rc Chutes available by special order. ➍ Kit includes Main Contacts and rc Chute Chamber. 136 Discount Schedule B6

18 Contactors Cross Reference, Series C1 & C6 to Series C9 (Open Type Only) ➊ Obsolete Contactor Cross Reference C1 or C6 to C9 Contactors Ratings for Switching C Motors (C2 / C3 / C4) Series C1 Series C6 Series C9 I e [] kw (50 Hz) UL/CS HP (60 Hz) Obsolete Obsolete Equivalent 400V / 1 Ø 3 Ø Catalog Catalog Catalog C-3 C-1 230V 415V 500V 690V 115V 230V 200V 230V 460V 575V Number Number Number / C C / C C / ~ C9-190 ~ ~ C C / ~ ~ ~ C / ~ ~ C / ~ ~ C9-305 ~ ~ C / C / ~ ~ C / C ~ ~ / C ~ ~ ~ / ~ C9-860 C1-10 Contactor 140-EI contactor ➊ vailable auxiliary contacts may vary. See selection pages for more information. 137

19 Technical Information Technical Information Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 UL; CS [V] [V] 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 1000V 600V 300-EI Rated Voltage U imp (kv) 12kV Rated Voltage U e - Main Contacts C 50/60Hz [V] 230, 240, 400, 415, 500, 690, 1000V DC [V] 24, 48, 110, 220, 440V Operating Frequency for C Loads [Hz] 50/60Hz 420-EI 630-EI 860-EI Switching Motor Loads Standard IEC Ratings C-2, C-3 230V [] DOL & Reversing 240V [] Hz 400V [] V [] 115(130)➊ 140(155)➊ 180(189)➌ 210(227)➊ 250(258)➊ 300(315)➊ V [] /140➋ 140(180)➊ V [] /140➋ 140(180)➊ ~ 1000V [] ~ ~ 230V [kw] V [kw] V [kw] V [kw] 66(75)➊ 82(90)➊ 105(110)➊ 122(132)➊ 145(150)➊ 176(185)➊ V [kw] 80 80(98)➋ 98(126)➊ V [kw] /135➋ 135(176)➊ ~ 1000V [kw] ~ ~ UL/CS 115V [] ~ ~ ~ ~ ~ ~ ~ DOL & Reversing 1 230V [] ~ ~ ~ ~ ~ 60Hz 115 V [HP] ~ ~ ~ ~ ~ ~ ~ 230 V [HP] ~ ~ ~ ~ ~ 200V [] V [] V [] V [] V [HP] V [HP] V [HP] V [HP] C4 (200,000 Op. Cycles) 230V [] ~ ~ 50Hz 240V [] ~ ~ 400/415V [] ~ ~ 500V [] ~ ~ 690V [] ~ ~ 1000V [] ~ ~ 230V [kw] ~ ~ 240V [kw] ~ ~ 400/415V [kw] / /80 90 / 100 ~ ~ 500V [kw] ~ ~ 690V [kw] ~ ~ 1000V [kw] ~ ~ Max. Operating Rate [ops/hr] ~ ~ ➊ Values in ( ) represent ratings for C-2 & C-3 and result in reduced lifespan of 25%. Use 400V values for full life span. ➋ Second number is rating for the -EI model. 138

20 Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI Technical Information 420-EI 630-EI Switching Motor Loads (continued) Wye-Delta (Star Delta) 230V [] ~ ~ 50Hz 240V [] ~ ~ 400V [] ~ ~ 415V [] 199(225) 242(268)➊ 312(332) 364(393)➊ 433(447)➊ 520(546)➊ 727 ~ ~ 500V [] / 242➋ ~ ~ 690V [] / 242➋ ~ ~ 1000V [] ~ ~ 230V [kw] ~ ~ 240V [kw] ~ ~ 400V [kw] ~ ~ 415V [kw] 114(132)➊ 132(160)➊ (335)➊ 425➊ ~ ~ 500V [kw] / 160➋ ~ ~ 690V [kw] / 220➋ ~ ~ 1000V [kw] ~ ~ 60 Hz 200V [HP] ~ ~ 230V [HP] ~ ~ 460V [HP] ~ ~ 575V [HP] ~ ~ UL/CS Elevator Duty 200V [] ~ ~ 230V [] ~ ~ 460V [] ~ ~ 575V [] ~ ~ 200V [HP] ~ ~ 230V [HP] ~ ~ 460V [HP] ~ ~ 575V [HP] ~ ~ C-1 Load, 3 Switching I th [] mbient Temperature 40 C 230V [kw] V [kw] V [kw] V [kw] V [kw] V [kw] V [kw] ~ ~ mbient Temperature 60 C I th [] ~ ~ 230V [kw] ~ ~ 240V [kw] ~ ~ 400V [kw] ~ ~ 415V [kw] ~ ~ 500V [kw] ~ ~ 690V [kw] ~ ~ 1000V [kw] ~ ~ 860-EI ➊ Values in ( ) represent ratings for C3 & C4 and result in reduced lifespan of 25%. Use 400V values for full life span. ➋ Rating 140 / 140-EI. 139

21 Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI Technical Information 860-EI Continuous Current (UL/CS) General Purpose Rating (40 C) Open [] Enclosed [] Lighting Loads Elect.Dischrg.Lamps-C-5a, Open [] ~ ~ single compensated Enclosed [] ~ ~ Incandescent Lamps - C-5b [] ~ ~ Switching power transformers C-6a Inrush Rated transformer current, P e n=30 240VC [] ~ ~ 230 VC [kv] ~ ~ 240 VC [kv] ~ ~ 400 VC [kv] ~ ~ 415 VC [kv] ~ ~ 500 VC [kv] ~ ~ 690 VC [kv] ~ ~ 1000 VC [kv] ~ ~ n = VC [] ~ ~ n = VC [] ~ ~ 60Hz Peak inrush/peak rated transformer n = 30 [] ~ ~ 200V [kv] ~ ~ 208V [kv] ~ ~ 240V [kv] ~ ~ 480V [kv] ~ ~ 600V [kv] ~ ~ 660V [kv] ~ ~ 60Hz Peak inrush/peak rated transformer n = 20 [] ~ ~ 200V [kv] ~ ~ 208V [kv] ~ ~ 240V [kv] ~ ~ 480V [kv] ~ ~ 600V [kv] ~ ~ 660V [kv] ~ ~ 60Hz Peak inrush/peak rated transformer n = 15 [] ~ ~ 200V [kv] ~ ~ 208V [kv] ~ ~ 240V [kv] ~ ~ 480V [kv] ~ ~ 600V [kv] ~ ~ 660V [kv] ~ ~ 140

22 Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI Technical Information 630(EI DC Ratings DC-1 Rating at 60 C Non-inductive or slightly 24VDC [] ~ ~ inductive loads, resistive 48VDC [] ~ ~ furnaces 110VDC [] ~ ~ 220VDC [] ~ ~ 1 Pole 440VDC [] ~ ~ 24VDC [] ~ ~ 48VDC [] ~ ~ 2 Poles in Series 110VDC [] ~ ~ 220VDC [] ~ ~ 440VDC [] ~ ~ 24VDC [] ~ ~ 48VDC [] ~ ~ 3 Poles in Series ➊ 110VDC [] ~ ~ 220VDC [] ~ ~ 440VDC [] ~ ~ 860-EI DC-3 Rating at 60 C Shunt wound motors - 24VDC [] ~ ~ Starting, reverse current 48VDC [] ~ ~ breaking, reversing, stepping 110VDC [] ~ ~ 220VDC [] ~ ~ 3 Poles in Series ➊ 440VDC [] ~ ~ DC-5 Rating at 60 C Series wound motors - 24VDC [] ~ ~ Starting, reverse current 48VDC [] ~ ~ breaking, reversing, stepping 110VDC [] ~ ~ 220VDC [] ~ ~ 3 Poles in Series ➊ 440VDC [] ~ ~ Three poles wired in series for DC switching + OPTION OPTION B ➊ See diagram to right for three poles wired in series for DC switching 141

23 Electrical Data 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI Capacitor Ratings C-6b Capacitor Switching - 50Hz Single Capacitor - 40 C 230 V [kvar] ~ ~ 240 V [kvar] ~ ~ 400 V [kvar] ~ ~ 415 V [kvar] ~ ~ 500 V [kvar] ~ ~ 690V [kvar] ~ ~ 1000 V [kvar] ~ ~ Single Capacitor - 60 C 230 V [kvar] ~ ~ 240 V [kvar] ~ ~ 400 V [kvar] ~ ~ 415 V [kvar] ~ ~ 500 V [kvar] ~ ~ 690V [kvar] ~ ~ 1000 V [kvar] ~ ~ Capacitor Bank- 40 C 230 V [kvar] ~ ~ 240 V [kvar] ~ ~ 400 V [kvar] ~ ~ 415 V [kvar] ~ ~ 500 V [kvar] ~ ~ 690V [kvar] ~ ~ 1000 V [kvar] ~ ~ Capacitor Bank- 60 C 230 V [kvar] ~ ~ Capacitor Switching - 60Hz 240 V [kvar] ~ ~ 400 V [kvar] ~ ~ 415 V [kvar] ~ ~ 500 V [kvar] ~ ~ 690V [kvar] ~ ~ 1000 V [kvar] ~ ~ Single Capacitor - 40 C 200 V [kvar] ~ ~ 230 V [kvar] ~ ~ 460 V [kvar] ~ ~ 600V [kvar] ~ ~ Capacitor Bank- 40 C 200 V [kvar] ~ ~ 230 V [kvar] ~ ~ 460 V [kvar] ~ ~ 600V [kvar] ~ ~ Technical Information 860-EI 142

24 Technical Information Electrical Data Short-Circuit Coordination Contactors without Motor Protection Relays 115(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI DIn Fuses - gg, gl vailable Fault Current [] 100 K 100 K 100 K 100 K 100 K 100 K 100 K ~ ~ Type 1 [] (355) ➊ ➊ Type 2 (380/400/415/690V) ➍ [] (315) Type 2 (1000V) ➍ [] (315) cul Short-Circuit Ratings Class K1, RK1, K5, and RK5 Fuses (L Fuses) vailable Fault Current [] 10 K 10 K 10 K 10 K 18 K 18 K 18 K 30 K 42 K cul Max. Rating (600V) ➌ Type 1 [] L-700 L-700 L-1000 L-2000 L-2500 Class J CS & HRCI-J Fuses ➋ vailable Fault Current [] 100 K 100 K 100 K 100 K 100 K 100 K 100 K ~ ~ cul Max. Rating (600V) ➌ Type 2 [] ~ ~ Circuit Breaker, inverse time ➎ vailable Fault Current [] 10 K 10 K 10 K 10 K 18 K 18 K 18 K 30 K 42 K cul Max. Rating (600V) ➌ Type 1 [] Short Time Current Withstand Ratings l cw 60 C 1 S [] (2550) ➋ ➊ ➊ 4 S [] (1970) ➋ S [] (1360) ➋ S [] (1130) ➋ S [] (850) ➋ ➊ ➊ 240 S [] (600) ➋ S [] (440) ➋ Off Time Between Operations [Min.] Resistance and Watt Loss I e C3 Resistance per power pole [mw] Watt Loss - 3 power poles [W] Coil and 3 power poles C [W] 24.5(20.5)➋ 34.6(30.6)➋ 50.8(46.8)➋ (@I ec3) DC [W] 22.5(20.5)➋ 32.6(30.6)➋ 48.8(46.8)➋ ➊ Under test. Contact your Sprecher + Schuh representative. ➋ Values in parentheses (_) are for the -EI- contactor. ➌ UL Listed Combination. (UL File E41850) Per UL508, NEC409 and CS 22.2 No.14 for contactor and fuses or circuit breaker only. ➍ Per IEC for contactor and fuses only. ➎ When used as a Branch Circuit Protection device, NEC defines the maximum rating of an Inverse-time circuit breaker to be sized at 250% of the motor nameplate FL for most applications. 143

25 Short Circuit Ratings High Fault Short Circuit Ratings per UL508 and CS 22.2 No.14 CEP7 Second Generation Cat. No. CEP7 EEHF EEJF EEJG EEKG Contactor Catalog No. Max. starter FLC () Max. available fault current (k) Fuse Ratings Max. voltage (V) UL Class J and CS HRCI-J fuse () CN CN CN CN EELG Technical Information & Overload Relay UL Listed Circuit Breaker Ratings ➊ Short Circuit Rating (k) Max. Voltage (V) Max. CB rating () ➊ Various Mfg. of UL Listed Circuit Breakers may be used. 144

26 Mechanical Data EI 140(-EI) 180(-EI) 210-EI 250-EI Technical Information 300-EI 420-EI Service Life Mechanical C [Mil.] DC [Mil.] Electrical C-3 (400V) [Mil.] R/F R/F Shipping Weights C - C6 [kg] (3.8) 3.3 (3.8) [Lbs] (8.4) 7.3 (8.4) DC - C6 [kg] (3.8) 3.3 (3.8) [Lbs] (8.4) 7.3 (8.4) Terminations - Power Type Direct Connection 630-EI Hexagonal Bolt b max. [mm] EI c max. [mm] s max. [mm] x 8 Ø min. [mm] Recommended Torque [Nm] [Lb-in] With Main Terminal Set (HB...) sm. opening [mm 2 ] ~ lg. opening [mm 2 ] ~ sm. opening [mm 2 ] ~ lg. opening [mm 2 ] ~ b max. [mm] ~ s. sm. opening [mm] ~ s. lg. opening [mm] ~ Recommended Torque [Nm] ~ Wire Size per UL/CS sm. opening [WG] #6...1 / 0 # MCM ~ lg. opening [WG] # MCM # MCM ~ Recommended Torque [Lb-in] ~ ➊ Minimum 25mm 2 (#4 WG) -95mm 2 (250mcm) with sleeve per DIN

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Series CA6 Contactors

Series CA6 Contactors Series CA6 Contactors The modern contactor for demanding applications from 75 to 600HP (@460V) - 00 to 700HP (@ 575V) Sprecher + Schuh s CA6 contactor line combines the simple function of our popular CA7

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross

More information

General + Definite Purpose Contactors

General + Definite Purpose Contactors General + Definite Purpose Contactors General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Contactors Series C8 Miniature Contactors and Starters... 3

More information

Technical Information

Technical Information Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

NEMA Space Saving Contactors and Starters

NEMA Space Saving Contactors and Starters Technical Data NEMA Space Saving Contactors and Starters Bulletin Numbers 300, 300S, 305, 309 Topic Page Summary of Changes 1 Product Description 2 Product Selection 3 Accessories (NEMA Sizes 0 3) 7 Accessories

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Manual Motor Protectors

Manual Motor Protectors 88 Manual Motor Protectors 51 30 UP TO IMM16 Frame IMM32 Frame IMM65 Frame E468295 E468295 High interrupt capacity up to 100k (with optional current limiter) Din rail mounting Lockable handle (OFF position)

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 1-D IEC Contactors kw @ 4V 6 6 Hp @ 46V 7 7 Hp @ 7V Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Capacitor Switching Contactors Type K3...-A, K3...-K

Capacitor Switching Contactors Type K3...-A, K3...-K Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Technical Information

Technical Information Technical nformation - Second Generation Solid State Overload Relays Technical nformation -ED1... -EE... -EE...D Rated nsulation Voltage - U [V] 69 C Rated nsulation Strength- U imp [kv] 6 C Rated Operation

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

For many applications

For many applications Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Electrical sector solutions E Line family. Industry leading design in a compact package

Electrical sector solutions E Line family. Industry leading design in a compact package Electrical sector solutions E Line family Industry leading design in a compact package The power of fusion. 87 88 89 899 90 908 9 9 9 9 97 97 977 98 98 989 999 There s a certain energy at Eaton. It s the

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Series CA7 Contactors

Series CA7 Contactors Series CA7 Contactors Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 75HP @ 46V Over years of design experience has produced Sprecher + Schuh s seventh generation

More information

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004

MPW Series. MPW Catalog Number Sequence. Standard Features MPW U004 Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,

More information

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors.

Contactors. 1.1 E Line contactors. 1.2 xstart series contactors. 1.3 xstart C series contactors. 1.4 D Line contactors. Contactors E Line contactors. E Line contactors. xstart series contactors.3 xstart C series contactors.4 D Line contactors xstart series contactors xstart C series contactors D Line contactors X UTOMTION

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

All round protection guaranteed

All round protection guaranteed s With SLR ll round protection guaranteed Betagard MCB 5SL Inspiring Safety nswers for infrastructure. Overview s a culture Siemens has always endeavoured to introduce innovative products worldwide. The

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Lighting Contactors. 6.1 Open Control. Product Overview...

Lighting Contactors. 6.1 Open Control. Product Overview... Lighting Contactors C30CN Mechanically and Electrically Held.1 Product Overview........................................ C30CN Mechanically and Electrically Held Product Description....................................

More information

Leadership driven by innovation

Leadership driven by innovation s Leadership driven by innovation Our innovations are your solutions for enhanced productivity LV Switchgear Motor Control Products Maximum etail Price w.e.f. 23 rd September, 203 Index Contents 2 Page

More information

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8

Motor Protection OLR. CEP7 Second Generation Solid State Overload Relays... B2 Technical Information... B8 Second Generation Solid State Overload Relays... 2 Technical Information... 8 CT7 Thermal Overload Relays... 17 Technical Information... 20 CT7K & CT4 Thermal Overload Relays... 25 Technical Information...

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

onlinecomponents.com

onlinecomponents.com Second Generation Solid State Overload Relays... 2 Technical Information... 8 CT7 Thermal Overload Relays... 17 Technical Information... 20 CT7K & CT4 Thermal Overload Relays... 25 Technical Information...

More information

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current 0 Series - General purpose relays - 0 Features 0. 0. Plug-in mount 0 General purpose relay & pole changeover contacts Cadmium Free contacts (preferred version) C coils & DC coils UL Listing (certain relay/socket

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

IDEC YC Contactors. New Contactors Now Available

IDEC YC Contactors. New Contactors Now Available New ors Now vailable IDEC YC ors TOC & Selection Guide YC ors Table of Contents Selection Guide...2 YC1N(K) Mini ors...3...3 ccessories...5 Specifi cations...5 Dimensions...6 Electrical Diagrams...6 YC1U

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information