SMP-2 Overload Relay. Product Selection Overview Feature SMP-1 SMP-2 SMP-3 TABLE OF CONTENTS. Description Page Description Page
|
|
- Gwendoline Elliott
- 6 years ago
- Views:
Transcription
1 3 ulletin 93 ulletin 93 SMP- Overload Relay SMP-3 Overload Relay SMP-2 Overload Relay Product Selection Overview Feature SMP- SMP-2 SMP-3 Self-Powered 3.2: djustment Range Phase Loss Protection Selectable Trip lass Ground Fault Protection JM Protection 5: djustment Range ommunications apability LED Status Indication SMP- Overload Relay Self-Powered Wide djustment Range (3.2:) mbient Temperature ompensation Visible Trip Indicator Phase Loss Protection SMP-2 Overload Relay Same as SMP- Plus: Selectable Trip lass (0, 5, 20 or 30) Ground Fault Tripping JM Protection SMP-3 Overload Relay Digital urrent Setting Ground Fault Tripping JM Protection ommunicates via R I/O or DeviceNet Trip ause Indication via LEDs, Human Interface Module or ommunication Network Uses ommon llen-radley ommunication Devices Selectable Trip lass (0, 5, 20 or 30) TLE OF ONTENTS Description Page Description Page Product Selection SMP-OverloadRelay SMP-2OverloadRelay SMP-3OverloadRelay ccessories Specifications Dimensions Description The SMP is a family of Solid-State Overload Relays. The complete line includes the SMP-, SMP-2, and SMP-3 overload relays. Each of these overload relays has unique features allowing for the choice of level of protection and features required for the application. The Product Selection Overview can be used for selection among the SMP overload relays. onformity to Standards: pprovals: IE S 22.2 No. 4 UL 508 IE 80 E Marked (Per EU Low Voltage Directives 73/23/EE 93/68/EE and per EU EM Directive 89/336/EE 9/263/EE 92/3/EE 93/68/EE) S ertified (File No. LR234) UL Listed (File No. E4840; Guide No. NKR) Your order must include: of overload relay selected with Voltage Suffix ode. If required, of any accessories. 3-43
2 ulletin 93 Product Selection SMP- Overload Relay Manual Reset 93-K4 Directly Mounts to ontactor 00 and 04 djustment Range ➊ Manual Reset for 3 pplications lass 0 lass 20 0 ➋ K4 93-2K L4 93-2L4 80 ➋ M5 93-2M5 Separately mounted for use with ulletin 00 and 04 contactors 0 ➋ L7 93-2L7 80 ➋ M7 93-2M7 250 and 300 ➋ N6 93-2N6 400 ➋ P6 93-2P6 600 ➋ R6 93-2R6 SMP- Overload Relay utomatic/manual Reset 93-4K4 Directly Mounts to ontactor 00 and 04 djustment Range ➊ utomatic/manual Reset for 3 pplications lass 0 lass 20 0 ➋ K4 93-5K L4 93-5L4 80 ➋ M5 93-5M5 Separately mounted for use with ulletin 00 and 04 contactors 0 ➋ L7 93-5L7 80 ➋ M7 93-5M7 250 and 300 ➋ N6 93-5N6 400 ➋ P6 93-5P6 600 ➋ R6 93-5R6 VoltageSuffixode The as listed is incomplete. Select a Voltage Suffix ode from the table below to complete the Example: 93-R6 becomes 93-R6D. For other coil voltages, contact your local llen-radley Distributor or Sales Office. Voltage 24V 0V 20V 208V 220V 240V 380V 45V 440V 480V 500V 600V 50 Hz K D T N I M 60 Hz J D H L G ➊ For motors with Service Factor of.5 or greater, use motor nameplate full load current. For motors with Service Factor of.0, use 90% of the motor nameplate full load current. ➋ Does not include Terminal Lugs. See ccessories on page 3-47 for listing. ccessories Page 3-47 Specifications Page 3-48 Dimensions Page
3 ulletin 93 Product Selection, ontinued SMP-2 Overload Relay utomatic/manual Reset, Field Selectable Trip lass 0, 5, 20 or 30, Jam and Ground Fault Tripping ➊➋ 93-K4 Directly Mounts to ontactor 00 and 04 djustment Range () ➊ 0 ➌ K L4 80 ➌ M5 Separately mounted for use with ulletin 00 0 ➌ L7 80 ➌ M7 250 and 300 ➌ N6 400 ➌ P6 600 ➌ R6 VoltageSuffixode The as listed is incomplete. Select a Voltage Suffix ode from the table below to complete the Example: 93-R6 becomes 93-R6D. For other coil voltages, contact llen-radley Distributor or Sales Office. Voltage 24V 0V 20V 208V 220V 240V 380V 45V 440V 480V 500V 600V 50 Hz K D T N I M 60 Hz J D H L G ➊ For motors with Service Factor of.5 or greater, use motor nameplate full load current. For motors with Service Factor of.0, use 90% of the motor nameplate full load current. ➋ Ground Fault tripping is inhibited for approximately 30 seconds to eliminate the possibility of nuisance tripping during motor starting. ➌ Does not include Terminal Lugs. See ccessories on page 3-47 for listing. ccessories Page 3-47 Specifications Page 3-48 Dimensions Page
4 ulletin 93 Product Selection, ontinued SMP-3 Overload Relay utomatic/manual Reset, Selectable Ground Fault Tripping ➊ and Jam Protection, Selectable Trip lass 0, 5, 20 or L4 Directly Mounts to ontactor 00 and 04 djustment Range () ➋ 0 ➌ L M4 80 ➌ M5 Separately mounted for use with ulletins 00 0 ➌ L7 80 ➌ M7 250 and 300 ➌ N6 400 ➌ P6 600 ➌ R6 VoltageSuffixode The as listed is incomplete. Select a Voltage Suffix ode from the table below to complete the Example: 93-R6 becomes 93-R6D. For other coil voltages, contact llen-radley Distributor or Sales Office. Voltage 0V 20V 208V 220V 240V 50 Hz D T 60 Hz D H L ➊ Ground Fault tripping is inhibited for trip class to reduce the possibility of nuisance tripping during motor starting. ➋ For motors with Service Factor of.5 or greater, use motor nameplate full load current. For motors with Service Factor of.0, use 90% of the motor nameplate full load current. ➌ Does not include Terminal Lugs. See ccessories on page 3-47 for listing. ccessories Page 3-47 Specifications Page 3-48 Dimensions Page
5 ulletin 93 ccessories Description nti-tamper Shield Provides protection against inadvertent adjustment of Reset mode selector and full load current settings. urrent djustment Shield Provides protection against inadvertent adjustment of the current setting. Used With SMP- SMP-2 SMP- SMP-2 Pkg. Qty Remote Reset Solenoid Terminal Lugs Flexible us onnector SMP- SMP-2 93-ER 93-4, 0 max. 99-LE 93- M5, 93- M7 80 max. 99-LF 93- N6 300 max. 99-LG 93- P6 400 max. 99-LH 93- R6 630 max LJ PG PH PJ External Reset utton for Enclosed Devices (IP66 Type 3/4/2) SMP- SMP-2 98-MR3 External Reset dapter SMP- 93-R 203-GD 93-HIM ommunication Module Remote I/O omm dapter 203-GD (20/240V Power) SMP-3 DeviceNet omm dapter 203-GK5 (20/240V Power) Human Interface Module SMP-3 93-HIM ommunication able (male to male) SMP-3 able Length /3 m m m m Illuminated Push utton Reset SMP-3 800T-NX3 Remote Reset able SMP-3 m 3m 6m 202-RR 202-RR3 202-RR6 VoltageSuffixode The as listed is incomplete. Select a voltage code from the table below to complete the Example: 93-ER becomes 93-ERD. For other voltages, consult your local llen-radley Distributor or Sales Office. Voltage 24V 48V 0V 5V 20V 220V 240V 50 Hz J D 60 Hz J D D Z24 Z48 Z0 Product Selection Page 3-44 Specifications Page 3-48 Dimensions Page
6 ulletin 93 Specifications Rated Thermal urrent of ontacts Ith () 5 5 Electrical Rating of ontacts () Utilization ategory 5 D3 (L/R=5ms) Voltage Ue SMP- SMP-2 SMP-3 Electrical Trip N larm N.O PF Rated Triac urrent () 0.5 Rated Insulation Voltage (V) Triacs Hard ontact S/UL IE Ui ontrol Voltage (V) 20 or % Operating Frequency (Hz) 50/60 50/60 50/60 Mechanical ody Material Thermoplastic Thermoplastic Thermoplastic ontact Material ontrol ontacts Fine Silver Fine Silver Silver Tin Terminal Marking enelec EN 5002 Max. Wire Size 93-4, L7 93-5, M with ulletin 99-L Terminal Lugs ontrol Terminals or 2 Operation Storage Temperature ompensation 50 mm 2 (#/0-WG) 20 mm 2 (#4/0-WG) 2.5 mm 2 (#2 WG) Environmental ( 4 04 F) ( F) ( 4 04 F) 50 mm2 (#/0-WG) 20 mm2 (#4/0-WG) 240 mm 2 (500 MM WG) 2 85 mm 2 (350 MM WG) mm 2 (500 MM WG) 2.5 mm2 (#2 WG) ( 4 04 F) ( F) ( 4 04 F) 50 mm2 (#/0-WG) 20 mm2 (#4/0-WG) 2mm2 (#4 WG) ( 4 04 F) ( F) ( 4 04 F) ltitude 2000M 2000M 2000M Product Selection Page 3-44 ccessories Page 3-47 Dimensions Page
7 Typical Tripping urves for SMP- and SMP-2 Overload Relays ulletin 93 Specifications, ontinued lass 0 Overload Relay ThetrippingtimeoftheSMPoverload relays can be estimated using the tables above and to the right lass 20 Trip Time (sec) Select the tripping class desired. 2. Locate the intersection of the approximate trip time curve with the proper multiple of current-setting found on the horizontal axis. 3. Read the approximate trip time in seconds along the vertical axis. trip Trip Time (sec) trip Multiples of Full Load mperes Multiples of Full Load mperes lass 5 (SMP-2 Only) lass 30 (SMP-2 Only) Trip Time (sec) trip Trip Time (sec) trip Multiples of Full Load mperes Multiples of Full Load mperes Product Selection Page 3-44 ccessories Page 3-47 Dimensions Page
8 ulletin 93 Specifications, ontinued Typical Tripping urves for SMP-3 Overload Relays lass 0 Overload Relay lass The tripping time of the SMP overload relayscanbeestimatedusingthetables above and to the right. Trip Time (sec) Select the tripping class desired. 2. Locate the intersection of the approximate trip time curve with the proper multiple of current-setting found on the horizontal axis. 3. Read the approximate trip time in seconds along the vertical axis. trip Trip Time (sec) Multiples of Full Load urrent Multiples of Full Load urrent trip lass lass Trip Time (sec) trip Trip Time (sec) trip Multiples of Full Load urrent Multiples of Full Load urrent Product Selection Page 3-44 ccessories Page 3-47 Dimensions Page
9 SMP-/SMP-2 Wiring Schematic ulletin 93 Specifications, ontinued L/ L2/3 L3/ T/2 T2/4 T3/6 Typical NEM Wiring Schematic Typical IE Wiring Schematic Typical SMP-3 Wiring Schematic SMP 3 INTERL TRI FUSE POWER SUPPLY SMP OUT OUT O/L L L2 Note: When power is supplied to 50 60, N.O. contact closes. 20V or 240V L NON-REVERSING L2 L REVERSING L INTERL TO SMP SMP INTERL TO SMP SMP F OUT O/L R O/L Note: oil voltage must be the same as L through L2 voltage. When power is supplied to 50 60, N.O. contact closes. 20 F R 2 Product Selection Page 3-44 ccessories Page 3-47 Dimensions Page
10 ulletin 93 Dimensions Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. SMP- and SMP-2 Overload Relays H G F E J D Type SMP- SMP-2 ontactor Width 9 (4-/6) 34 (5-9/32) Height 276 (0-7/8) 33 (3-/32) Depth 55 (6-7/64) 90 (7-3/64) D E F G H J 42 (5-9/32) 63 (6-27/64) 85.6 (7-5/6) 22. (8-23/32) 30 (5-/8) 60 (6-5/6) 00 (3-5/6) 0 (4-2/64) 4.3 (-5/8) 48.8 (-59/64) SMP-3 Overload Relay H J G F E D Type SMP-3 ontactor Width 9 (4-/6) 34 (5-9/32) Height 3 (2-/4) 366 (4-3/32) Depth 55 (6-7/64) 90 (7-3/64) D E F G H J 59 (6-/4) 86 (7-5/6) 76 (6-5/6) 2 (8-5/6) 30 (5-/8) 60 (6-5/6) 00 (3-5/6) 0 (4-2/64) 3.9 (35/64) 2.4 (27/32) 3-52
11 ulletin 93 Dimensions, ontinued Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. SMP- Overload Relay with urrent Transformer D E.28 (7-5/6) 3 HOLES 93-_P6 D E 93-_N6 93-_P6 93-_R (7) 77.3 (7) (0-/4) 99.8 (7-7/8) (0-7/6) (3-/6) (9-/4) (9-/4) (8-/6) 20 (4-3/4) 20 (4-3/4) 80. (7-/8) 56 (6-3/6) 56 (6-3/6) 226. (8-5/6) pprox. Shipping Wt. kg (lb) 4.4 (9.75) 4.4 (9.75) 6.8 (5.0) SMP-3 Overload Relay with urrent Transformer LLEN RDLEY D E.28 (7-5/6) 3 HOLES 93-P6 D E 93-N6 93-P6 93-R6 77 (7) 77 (7) 250 (9-7/8) 200 (7-7/8) 265 (0-7/6) 347 (3-/6) 285 (-/4) 285 (-/4) 272 (0-3/4) 20 (4-3/4) 20 (4-3/4) 80 (7-/8) 58 (6-/4) 56 (6-3/6) 226 (8-5/6) pprox. Shipping Wt. kg (lb) 4.8 (0.75) 4.8 (0.75) 7.5 (5.75) Product Selection Page 3-44 ccessories Page 3-47 Specifications Page
Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents
Definite Purpose ontactors & Starters - July 007 Definite Purpose ontactors & Starters ontents Description Page Product Family Overview pplication Description........................................ -
More informationDefinite Purpose Control. Product Focus
Product Focus Innovation in Eaton s utler-hammer efinite Purpose (P) ontactors are designed to improve control of refrigeration, air conditioning, ventilation and resistance heating applications. The
More informationDisconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494
Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications
More informationTechnical Information
Technical nformation - Second Generation Solid State Overload Relays Technical nformation -ED1... -EE... -EE...D Rated nsulation Voltage - U [V] 69 C Rated nsulation Strength- U imp [kv] 6 C Rated Operation
More informationTABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:
3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches
More informationVariable Frequency AC Motor Drive Units
14 Variable Frequency A Motor Drive Units ulletin 2162T and 2163T PowerFlex 40 Drive................................................. 171 These combination variable frequency A motor drive units are specifically
More information4.2. Definite Purpose Contactors and Starters. Contents A, Two-, Three- and Four-Pole C25. Contactors
.2 Definite Purpose and Starters 5 360, Two-, Three- and Four-Pole 25 5 360, Two-, Three- and Four-Pole 25 Product Description Eaton offers the most comprehensive line of definite purpose contactors in
More informationMotor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors
Selection ompact Definite Purpose Motor ontrol TLOG SELETION Definite Purpose ing System 2 D N 2 Model = ontactor = Three-Phase Starter = Single-Phase Starter Type 2 = Non-Reversing 27 = Non-Reversing
More information28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description
.1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is
More information150 C 30 F B D 8L 152H C 30 F BD 43 8L
SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number ode Solid-State ontroller b ontroller Type ode SM- c Ampere s ode A A A A A A A A A A
More informationNEMA Contactors and Starters
NM ontactors and Starters NM N16DN0 NM Size 1 Starter.1 Freedom Series Product Overview........................................ Features, enefits and Functions............................ Standards and
More informationBulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents
Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures
More information.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th
NM ontactors and Starters NM N16N0 NM Size 1 Starter.1 Product Overview.............................................. Features, enefits and Functions.................................. Standards and ertifications......................................
More informationNEMA Contactors and Starters
NM ontactors and Starters NM N16N0 NM Size 1 Starter NM Size 1 ontactor.1 Product Overview.............................................. 242 Features, enefits and Functions..................................
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationStarters. NEMA Contactors & NEMA Contactors & Starters Contents
January Vol., Ref. No. [007] - NM ontactors & Starters ontents Page Freedom Line Product Family Overview......................................... - ontactors Non-reversing and Reversing.........................
More informationNEMA Contactors & Starters A200
March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product
More informationAllen-Bradley 800T-FXD16RA1
NEM Push utton Specifications 800T/H 30.5 mm Push uttons 2-Position Push-Pull and Push-Pull/Twist Release Devices, Illuminated Note: jumbo or large legend plate is recommended, if space allows. Illuminated
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationOpen, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts
0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,
More informationL2 FWD REV L1 L2 L1 L2 L3 FWD REV (L.H. UNIT) (R.H. UNIT) HIGH LOW HIGH LOW
Manual ontrol lass - RV, SMF, MMS 0/0/ lass - RV Signaling ontact for lass - RV Typical lass SMF RV9-M Typical MMS Reversing Manual Starter and Manual Motor Starting Switches -Speed Manual Motor Starting
More information800 T P B H 16 R. Momentary Contact Push Button Devices, Illuminated. 8 Rockwell Automation Publication 800-TD009A-EN-P
Momentary Contact Push utton Devices, Illuminated Extended Head Without Guard Cat. No. 800T-P16R Extended Head without Guard Cat. No. 800H-PR16R 800 T P H 16 R a Protection Rating T Metal, Type 4/13 H
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More information[V] Common Control Transformer Control (See page 1-78 Note)
Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state
More informationBulletin 1494F 30A, 60A, 100A Fixed-Depth Disconnect Switch (Cat 1494F-N30; 1494F-N60; 1494F-N100; Series C)
Installation Instructions ulletin 1494F, 60, Fixed-epth isconnect Switch (at 1494F-N30; 1494F-N60; 1494F-N100; Series ) WRNING: To prevent electrical shock, disconnect from power source before installing
More informationEDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards
-P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationSeries MTO. Thermal overload relays. Thermal overload relays. for minicontactors from 0.11 to 14A. Standards. General characteristics.
Series MTO for minicontactors from 011 to 14 ontrol circuit up to 690V Power circuit up to 690V Three-pole differential (phase unbalance protection) utomatic ambient temperature compensation between 25º
More informationTechnical Information
C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /
More informationMAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-
MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More informationF-Series General Specifications
arling F-Series General Specifications F-Series breakers are available up to 700, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method
More informationPresentation, Application Severe Duty Limit Switches Mill and Foundry Switches Conforming to NEMA A600 and UL508
Presentation, pplication Severe uty Limit Switches 0 onforming to NEM 600 and UL508 escription 9007T Mill Switches Use the 9007T Mill switches instead of other limit switches in the following applications:
More informationContactors & Starters Index
ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic
More informationGeneral + Definite Purpose Contactors
General + Definite Purpose General Information... 2 Horse Power Rating Charts... 4 Contact Life... 8 Contactor Number Structure... Series C8 Miniature and Starters... 3 ccessories... 2 Contactor Cross
More informationSTC Starting Torque Controller A Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3
7 Bulletin 150 Reduced Voltage Starters Section Overview STC Starting Torque Controller 11 22 Ratings Reduces Starting Torque Surge Feed-Through Wiring Single- and Three-Phase Page 7-3 SMC-2 Smart Motor
More informationElectronic Temperature Control & Bulb Well Assembly (AC)
Electronic Temperature ontrol & ulb Well ssembly () 0916 86816 This is a line voltage single-stage electronic temperature control with singlepole, double-throw relay output and LED indication. It is designed
More informationTechnical Information
Electrical Data C7-9 Rated Insulation Voltage U i IEC, S,BS,SEV, VDE 0660 [V] 690V UL; CS [V] 600V Rated Impulse Voltage U imp [kv] 8kV Rated Voltage U e -Main Contacts C7 3-Pole Contactors C7-2 C7-6 C7-23
More informationGE Industrial Solutions. New. Ed. 02. New contactors and starter combinations for demanding applications. GE imagination at work
GE Industrial Solutions New Ed 02 New contactors and starter combinations for demanding applications GE imagination at work Efficor - new dimension in global contactors dvantages and enefits 2 Introduction
More informationQO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories
QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.
More information800 T FX 1 A1. Color Cap. No cap 1 Green 2 Black 3 Orange 4 Grey 5 White 6 Red 7 Blue 9 Yellow. Contact Block(s) Operator Position.
NEM Push utton Specifications 800T/H 30.5 mm Push uttons 2-Position Push-Pull and Push-Pull/Twist Release Devices, Non-Illuminated Note: jumbo or large legend plate is recommended, if space allows. 2-Position
More informationStandard voltages. Alternating current (V) /60Hz Alternating current (V)
Series K Three and four pole contactors 150 to 825 (3) 200 to 1250 (1) ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K13:
More informationPump Panels Type 3R Enclosure
Type R Enclosure Product Family Overview June 6 Product escription The utler-hammer Pump ontrollers from Eaton s electrical business are combination starters with accessories and modifications designed
More informationG7150D, 3-Way, Diverting Flanged Globe Valve
G7150D, 3-ay, Diverting Flanged Globe Valve pplication This valve is typically used in Large ir Handling Units on heating or cooling coils. This valve is suitable for use in a hydronic system with variable
More informationGE Consumer & Industrial. M-PACT New Air Circuit Breaker A
GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State
More informationCI-TI TM Contactors and Motor Starters Contactors CI 6-50
Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9
More informationTOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS.
TOUGH ENVIRONMENTS. REQUIRE TOUGH PRODUCTS. NEM VCUUM CONTCTORS NEM VCUUM OPEN TYPE STRTERS NEM VCUUM COMBINTION STRTERS NEM VCUUM PUMP CONTROL PNELS INTRODUCING THE NEW LINE OF LLEN-BRDLEY NEM VCUUM CONTCTORS
More informationP-SERIES VFD WITH BYPASS
P-SERIES VFD WITH BYPSS 1 40 HP (200~230 VC) 1 100 HP (380~480 VC), 3Ø Enclosed Bypass - UL Type 3R Standard Controls for Bypass & Local/Remote Operation Special Instructions: FETURES ND OPTIONS Compact
More informationAmbient temperature compensation (-40F to +1400F) Phase loss sensitivity protection, Current unbalance sensitivity.
www.we.net Thermal Overload Relays - RW Series Rated for the new industry RW overload relays are an important part of WEG rane of products. s usual in WEG products, an extended operational service life
More informationPage 2-4 Page 2-8. Page Page 2-12
Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V
More informationStandard voltages. Alternating current (V) /60Hz Alternating current (V)
Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07K3: auxiliary
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...
Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More information600V, Non-Fusible, (3-Pole, 3 Phase)
0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless
More informationDMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc.
omputer Weld Technology, Inc. 070 Old ammel N Houston Rd. Houston, TX 77086 Telephone: (7) 46-8 Fax: (7) 46-50 DM-500 TM D Motor Drive ontrol Operation / Installation Manual Manual Part Number: S8M500
More informationSelection Information Molded Case Circuit Breakers
Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15
More informationA Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.
C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,
More informationEIC combination motor starters
pplications: Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining cross-the-line starting
More informationVariable speed drives
5 192 Variable speed drives SED2 Variable speed drives for speed control of three-phase a.c. motors actuating fans or pumps. Range: 0.75 kw to 90 kw for IP20/21 version, 1.1 kw to 90 kw for IP54 version.
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated
More informationContactors & Overload relays
Contactors & Overload relays Metasol MC 3P 18 to 100 MC type Magnetic Contactors Frame size screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency
More informationEfficor* Intro. Conformity to standards. Ambient conditions. Climatic resistance (IEC 68-2) Approvals/Marking. Mounting positions
fficor* onformity to standards /N 60947-1 04 /N 60947-4-1 UL508 /N 60947-5-1 UL486 /N 60947-5-4 S22- N500 N 16 101/102 N50012 N50005 pprovals/marking mbient conditions Storage temperature -55º to +80º
More informationFeatures. P d max. (W) V max (Vdc) I max (A)
POLY-FUSE Resettable PTs Radial Leaded > USR Series USR Series RoHS escription The USR Series radial leaded device is designed to provide overcurrent protection for US applications where space is not a
More informationPlumbing S Plumbing S Frame S-100. Enclosure A20H16CLP. Pump & Motor S-400 FRONT RIGHT ISO VIEW NEW LOGIC RESEARCH
Plumbing S-00-0 Plumbing S-00-0 Frame S-00 Enclosure 0H6LP Pump & Motor S-00 FRONT RIGHT ISO VIEW NOTES:.ll dimensions are for references only..nlr confidential material. RWN HEKE //007 NEW LOGI RESERH
More informationNB1 Miniature Circuit Breaker
P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide
More information9070T150D1 Industrial Control Transformer, 150VA
Product Data Sheet 9070T150D1 Industrial ontrol Transformer, 150 Technical haracteristics Application Approvals atalog Reference Number Depth Height Width Winding Material Temperature Rise Type Primary
More informationMPW Series. MPW Catalog Number Sequence. Standard Features MPW U004
Series The WEG Series Manual provide a very compact solution for operation and protection in motor control applications. The NEC requires four functions to be considered a combination motor starter:, ranch,
More informationJune 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]
7-2 Lighting ontactors Open ontrol June 2005 N5 lectrically Held Vol. 2, Ref. No. [09] ontents eatures Instructional Leaflets 7 escription Page lectrically Held Product escription....... 7-2 pplication
More informationPSE The efficient range Description
Description The PSE softstarter range is the world s first compact softstarters with Torque Control. This makes the PSE range an excellent choice for pumping application where water hammering normally
More informationFor full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.
Safety Interlock Switches D4JL D4JL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Holding
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationTechnical Information
Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage
More informationQO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers
QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for
More informationSeries CK. Contactors. Intro. Mounting positions
onformity to standards /N 60947-1 N 63-110 S 5424 & 775 /N 60947-4-1 S 1025 NM S 1 NL 419 S 22.2/14 V 0660/102 UL 508 UN 20109 N 50005 pprovals/marking culus RN NOM Lloyd s Register ureau Veritas mbient
More informationFault Code 16: Eaton Proprietary Link (EPL)
ault ode 16: aton Proprietary Link (PL) ault Isolation Procedure ault ode 16: aton Proprietary Link (PL) 1587:MI 130 SI 248 MI 2 Overview ault ode 16 indicates the Shift ontroller and the Transmission
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More information152H F480 F BD B 59 8B
ulletin Catalog Number Explanation Open and Non-Combination F F D L a ulletin Number Solid-State Controller F F F F F F F F F F F F F F F F Combination H H F F F F F F F F F F F F F F Enclosed Solid-State
More informationApplication Engineering
Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor
More informationEfficor. Most reliable technology. High installation benefits. Best in class. Standards. Approvals. Global contactors. Intro. J/X New A.
Most reliable technology igh installation benefits lobal contactors Standard materials for food & beverage and transportation purposes complying the latest rail standards ighest reliable product performance
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER 1 & 3 Phase, 50/60Z, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides a simple and dependable starting option with a wide electronic overload
More informationMini Contactors CI 4-
Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationStandard voltages. Alternating current (V) 50/60Hz Alternating current (V)
Series CK Three and four pole contactors 150 to 825 (C3) 200 to 1250 (C1) Control circuit: lternating current up to 690V Direct current up to 500V Degree of protection IP00 (IPxx with accessories) CK07...CK13:
More informationCerti cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic
Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers
More information2.7. Limit Switches. Contents Description. E50 Heavy-Duty Factory Sealed 6P+ Switches. E50 Heavy-Duty Factory Sealed 6P+ Switches
ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com.7 E50 Heavy-Duty Factory Sealed 6P+ Switches E50 Heavy-Duty Factory Sealed 6P+ Switches
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary 2. General characteristics 3. Fixed circuit breaker 4. Withdrawable circuit breakers 5. haracteristics 6. RV23: protection and control unit 6. RV+ : protection
More informationE C N A A F -
33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40
More informationRSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A
Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial
More informationDesigned for ease of integration with automation systems
BAS, 200 ~ 600V, 1/2-30HP BUILDING AUTOMATION STARTER SMARTER AND MORE VERSATILE THAN EVER Smartstart Equipped with advanced I/O including Fireman s Override and damper control, the BAS was designed from
More informationApplications Mill Mill Mill Mill. 9007T Convertible sequence. L100 Fixed sequence. Extra heavy duty contact ratings. Extra heavy duty contact ratings
Selection Guide Severe Duty Mill and Foundry Switches pplications Mill Mill Mill Mill Design 9007T Convertible sequence L0 Fixed sequence L14 Single Cable Pulls Fixed sequence L525 elt Conveyor Fixed sequence
More informationPK Installation Instructions for the 2CPS Series Cable Pull Switch Without Broken Cable Detection ISSUE 3. Sensing and Control
ISSUE 3 Installation Instructions for the 2PS Series able Pull Switch Without roken able Detection PK 80169 WRNING IF USED IN PPLITIONS ONERNING HUMN SFETY Only use N direct opening ( positive opening
More informationR1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up
Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in
More informationches UL File No. E101598
Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the
More informationLED DRIVERS. Version number: SCN1401
LED DRIVERS Version number: SN1401 bout us LED Drivers and Solutions Provider Four Invention Patents of ntisurge: Perfect Solution for ntisurge LED Street Light Perfect Solution for LED Triac Dimming Light
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories
Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks
More informationG7100S, 3-Way, Mixing Flanged Globe Valve
pplication This valve is typically used in large ir Handling Units (HU) on heating or cooling coils. This valve is suitable for use in a hydronic system with variable flow. Suitable ctuators Non-Spring
More informationOperation and Protection of Motors up to 600Hp at 460Vac (800A)
Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components
More informationJFA CONNECTOR METAL SHELL SERIES
JF ONNETOR METL SHELL SERIES Wire-to-wire connectors (For Interface) Metal shell type I/O connector which contacts are used also with JF connector J2000 series and J300 series. pplicable contact and tooling
More information