TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights

Size: px
Start display at page:

Download "TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights"

Transcription

1 TEST REORT EN Luminaires art 2: articular requirements Section 21: Rope Lights Report reference No.... : ED S Tested by... : Coral Chen Approved by... : Kobe Mai Date of issue... : August 16, 2017 Contents... : 54 pages Testing laboratory Name... : EMTEK(DONGGUAN) CO., LTD. Address... : No.281, Guantai Road, Nancheng District, Dongguan, Guangdong, China. Testing location... : Same as above Client Applicant name... : GLOBAL(LED) LIGHTING SOLUTIONS Address... : Suite 402, 4th oor, Northbank Buiding Lane, Northbank Lane Century City Town,7441 Manufacturer name... : GLOBAL(LED) LIGHTING SOLUTIONS Address... : Suite 402, 4th oor, Northbank Buiding Lane, Northbank Lane Century City Town,7441 Factory name... : GLOBAL(LED) LIGHTING SOLUTIONS Address... : Suite 402, 4th oor, Northbank Buiding Lane, Northbank Lane Century City Town,7441 Test speci cation Standard... : EN :2015 used in conjunction with EN :2015 Test procedure... : Safety rocedure deviation... : Non-standard test method... : Test item roduct name... : x-glo strip light Trademark... : Model and/or type reference... : x-glo v Rating(s)... : 110V~; 50/60Hz; 13W/m, Max. 4.8A TRF NO.: IEC60598_2_21A age 1 of 54 Report N o.: ED S Ver.1.0

2 Test item particulars... : Classification of installation and use... : -- Supply Connection... : Supply cord... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Testing Date of receipt of test item... : July 27, 2017 Date (s) of performance of tests... : July 27, 2017 to August 16, 2017 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC Summary of testing: 1. There are one model covered in this report. 2. Full tests were performed on model x-glo v. And the tests results complied with the requirements of the standards mentioned in page one. 3. EN :2015, EN :2001 was considered, details see Attachment No.1 4. EN 62301:2008+A1:2013+A2:2015 was considered, details see Attachment No IEC/TR 62778: 2014 was considered in this report, the RG level of this product is exempt group. Details see Attachment No.3 6. EN 62471: 2008 was evaluated, classification group: exempt risk 1 risk 2 risk 3, details see report ED S. TRF NO.: IEC60598_2_21A age 2 of 54 Report No.: ED S Ver.1.0

3 Copy of marking plate: Sticking on the luminaires Note: 1. The height of graphical symbols shall not be less than 5 mm. 2. The height of letters and numerals either shown separately or with or as part of symbols shall not be less than 2 mm. 3. The height of WEEE symbols shall not be less than 7 mm. General product information: 1. LED chains, Class II; I The product connected to supply without plug. 3. Flexible sealed lighting chains. TRF NO.: IEC60598_2_21A age 3 of 54 Report No.: ED S Ver.1.0

4 21.4 (0) GENERAL TEST REQUIREMENTS 21.4 (0.1) Information for luminaire design considered... : Yes No Lamp standard: 21.4 (0.3) More sections applicable... : Yes No Section/s: 21.5 (2) CLASSIFICATION 21.5 (2.2) Type of protection... : Class II 21.5 (2.3) Degree of protection... : I (2.4) Luminaire suitable for direct mounting on normally flammable surfaces... : Yes No 21.5 (2.5) Luminaire for normal use... : Yes No Luminaire for rough service... : Yes No (-) Class II or Class III Class II (-) Rope lights for outdoor use shall be I44 or higher I (3) MARKING 21.6 (3.2) Mandatory markings osition of the marking Format of symbols/text 21.6 (3.3) Additional information Language of instructions English 21.6 (3.3.1) Combination luminaires 21.6 (3.3.2) Nominal frequency in Hz 50/60Hz 21.6 (3.3.3) Operating temperature 21.6 (3.3.4) Symbol or warning notice 21.6 (3.3.5) Wiring diagram 21.6 (3.3.6) Special conditions 21.6 (3.3.7) Metal halide lamp luminaire warning 21.6 (3.3.8) Limitation for semi-luminaires 21.6 (3.3.9) ower factor and supply current 21.6 (3.3.10) 21.6 (3.3.11) Suitability for use indoors Luminaires with remote control TRF NO.: IEC60598_2_21A age 4 of 54 Report No.: ED S Ver.1.0

5 21.6 (3.3.12) 21.6 (3.3.13) 21.6 (3.3.14) 21.6 (3.3.15) 21.6 (3.3.16) 21.6 (3.3.17) 21.6 (3.3.18) 21.6 (3.3.19) 21.6 (3.3.20) 21.6 (3.3.21) 21.6 (3.3.22) Clip-mounted luminaire warning Specifications of protective shields Symbol for nature of supply ~ Rated current of socket outlet Rough service luminaire Mounting instruction for type Y, type Z and some type X attachments Non-ordinary luminaires with VC cable rotective conductor current in instruction if applicable rovided with information if not intended to be mounted within arm s reach Non replaceable and non-user replaceable light sources information provided Cautionary symbol Controllable luminaires, classification of insulation provided type Y Non replaceable light sources 21.6 (3.4) Test with water 15S Test with hexane 15S Legible after test Label attached (-) Rope light marking Rated voltage and wattage marked on the rope light Durable non-removable label if information on the cable (-) Rope light and packing marking Marking if only for indoor use (-) Marking on the packing or instructions Marking a) e) (4) CONSTRUCTION (4.2) Components replaceable without difficulty (4.3) Wireways smooth and free from sharp edges TRF NO.: IEC60598_2_21A age 5 of 54 Report No.: ED S Ver.1.0

6 (4.4) Lampholders (4.4.1) Integral lampholder (4.4.2) Wiring connection (4.4.3) Lampholder for end-to-end mounting (4.4.4) ositioning - pressure test (N)... : After test the lampholder comply with relevant standard sheets and show no damage After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation - bending test (N)... : After test the lampholder have not moved from its position and show no permanent deformation (4.4.5) eak pulse voltage (4.4.6) Centre contact (4.4.7) arts in rough service luminaires resistant to tracking (4.4.8) Lamp connectors (4.4.9) Caps and bases correctly used (4.4.10) Light source for lampholder or connection according IEC not connected another way (4.5) Starter holders Starter holder in luminaires other than class II Starter holder class II construction (4.7) Terminals and supply connections (4.7.1) Contact to metal parts (4.7.2) Test 8 mm live conductor Test 8 mm earth conductor (4.7.3) Terminals for supply conductors ( ) Welded method and material - stranded or solid conductor - spot welding - welding between wires - Type Z attachment - mechanical test according to electrical test according to TRF NO.: IEC60598_2_21A age 6 of 54 Report No.: ED S Ver.1.0

7 - heat test according to and (4.7.4) Terminals other than supply connection (4.7.5) Heat-resistant wiring/sleeves (4.7.6) Multi-pole plug - test at 30 N (4.8) Switches - adequate rating - adequate fixing - polarized supply - compliance with IEC for electronic switches (4.9) Insulating lining and sleeves (4.9.1) Retainment Method of fixing... : (4.9.2) Insulated linings and sleeves: Resistant to a temperature > 20 C to the wire temperature or a) & c) Insulation resistance and electric strength b) Ageing test. Temperature ( C)... : (4.10) Double or reinforced insulation (4.10.1) (4.10.2) (4.10.3) No contact, mounting surface accessible metal parts wiring of basic insulation Safe installation fixed luminaires Capacitors and switches Interference suppression capacitors according to IEC Assembly gaps: - not coincidental - no straight access with test probe Retainment of insulation: - fixed - unable to be replaced; luminaire inoperative - sleeves retained in position - lining in lampholder (4.11) Electrical connections and current-carrying parts TRF NO.: IEC60598_2_21A age 7 of 54 Report No.: ED S Ver.1.0

8 (4.11.1) (4.11.2) (4.11.3) (4.11.4) (4.11.5) (4.11.6) Contact pressure Screws: - self-tapping screws - thread-cutting screws Screw locking: - spring washer - rivets Material of current-carrying parts No contact to wood or mounting surface Electro-mechanical contact systems (4.12) Screws and connections (mechanical) and glands (4.12.1) (4.12.2) (4.12.4) (4.12.5) Screws not made of soft metal Screws of insulating material Torque test: torque (Nm); part... : Torque test: torque (Nm); part... : Torque test: torque (Nm); part... : Screws with diameter < 3 mm screwed into metal Locked connections: Screw for fixing fuse box: 2.92mm, 0.5Nm - fixed arms; torque (Nm)... : - lampholder; torque (Nm)... : - push-button switches; torque 0,8 Nm... : Screwed glands; force (Nm)... : 2.5Nm (4.13) Mechanical strength (4.13.1) Impact tests: - fragile parts; energy (Nm)... : - other parts; energy (Nm)... : 0.5 Nm 1) live parts TRF NO.: IEC60598_2_21A age 8 of 54 Report No.: ED S Ver.1.0

9 (4.13.3) (4.13.4) (4.13.6) 2) linings 3) protection 4) covers Straight test finger 30N Rough service luminaires - I54 or higher a) fixed b) hand-held c) delivered with a stand d) for temporary installations and suitable for mounting on a stand Tumbling barrel (4.14) Suspensions, fixings and means of adjusting (4.14.1) (4.14.2) (4.14.3) Mechanical load: A) four times the weight B) torque 2,5 Nm C) bracket arm; bending moment (Nm)... : D) load track-mounted luminaires E) clip-mounted luminaires, glass-shelve. Thickness (mm)... : Metal rod. diameter (mm)... : Fixed luminaire or independent control gear without fixing devices Load to flexible cables Mass (kg)... : Stress in conductors (N/mm²)... : Mass (kg) of semi-luminaire... : Bending moment (Nm) of semi-luminaire... : Adjusting devices: - flexing test; number of cycles... : - strands broken... : - electric strength test afterwards TRF NO.: IEC60598_2_21A age 9 of 54 Report No.: ED S Ver.1.0

10 (4.14.4) (4.14.5) (4.14.6) Telescopic tubes: cords not fixed to tube; no strain on conductors Guide pulleys Strain on socket-outlets (4.15) Flammable materials (4.15.2) - glow-wire test 650 C... : See Test Table (13.3.2) - spacing 30 mm - screen withstanding test of screen dimensions - no fiercely burning material - thermal protection - electronic circuits exempted Luminaires made of thermoplastic material with lamp control gear a) construction b) temperature sensing control c) surface temperature (4.16) Luminaires for mounting on normally flammable surfaces (4.16.1) (4.16.2) (4.16.3) No lamp control gear... : (compliance with Section 12) Lamp control gear spacing: - spacing 35 mm - spacing 10 mm Thermal protection: - in lamp control gear - external - fixed position - temperature marked lamp control gear Design to satisfy the test of 12.6 (see clause 12.6) (4.17) Drain holes Clearance at least 5 mm (4.18) Resistance to corrosion TRF NO.: IEC60598_2_21A age 10 of 54 Report No.: ED S Ver.1.0

11 (4.18.1) (4.18.2) (4.18.3) - rust-resistance - season cracking in copper - corrosion of aluminium (4.19) Ignitors compatible with ballast (4.20) Rough service vibration (4.21) rotective shield (4.21.1) (4.21.2) (4.21.3) (4.21.4) Shield fitted if tungsten halogen lamps or metal halide lamps Shield of glass if tungsten halogen lamps articles from a shattering lamp not impair safety No direct path Impact test on shield Glow-wire test on lamp compartment... : See Test Table (13.3.2) (4.22) Attachments to lamps not cause overheating or damage (4.23) Semi-luminaires comply Class II (4.24) hotobiological hazards (4.24.1) (4.24.2) No excessive UV radiation if tungsten halogen lamps and metal halide lamps (Annex ) Retinal blue light hazard Luminaires with Ethr : a) Fixed luminaires RG0 - distance x m, borderline between RG1 and RG2.. : - marking and instruction according b) ortable and handheld luminaires - marking according if RG1 exceeded at 200 mm according to IEC/TR ortable luminaires for children IEC and Mains socket outlet nightlights IEC not exceed RG1 at 200 mm according to IEC/62778 (4.25) Mechanical hazard No sharp point or edges TRF NO.: IEC60598_2_21A age 11 of 54 Report No.: ED S Ver.1.0

12 (4.26) Short-circuit protection (4.26.1) (4.26.2) Adequate means of uninsulated accessible SELV parts Short-circuit test with test chain according Test chain not melt through Test sample not exceed values of Table 12.1 and 12.2 (4.27) Terminal blocks with integrated screwless earthing contacts Test according Annex V ull test of terminal fixing (20 N) After test, resistance < 0,05 ull test of mechanical connection (50 N) After test, resistance < 0,05 Voltage drop test, resistance < 0,05 (4.28) Fixing of thermal sensing control Not plug-in or easily replaceable type Reliably kept in position No adhesive fixing if UV radiations from a lamp can degrade the fixing Not outside the luminaire enclosure Test of adhesive fixing: Max. temperature on adhesive material ( C)... : 100 cycles between t min and t max Temperature sensing control still in position (4.29) Luminaires with non-replaceable light source Not possible to replace light source Live part not accessible after parts have been opened by hand or tools (4.30) Luminaires with non-user replaceable light source If protective cover provide protection against electric shock and marked with caution, electric shock risk symbol: Minimum two fixing means (4.31) Insulation between circuits Circuits insulated from LV supply fulfil requirements according TRF NO.: IEC60598_2_21A age 12 of 54 Report No.: ED S Ver.1.0

13 (4.31.1) (4.31.2) (4.31.3) Controllable luminaires requiring same level of insulation for all components, the insulation between control terminals and LV supply fulfil requirements according SELV circuits Used SELV source Voltage ELV Insulating of SELV circuits from LV supply Insulating of SELV circuits from other non SELV circuits Insulating of SELV circuits from FELV Insulating of SELV circuits from other SELV circuits SELV circuits insulated from accessible parts according Table X.1 lugs not able to enter socket-outlets of other voltage systems Socket outlets does not admit plugs of other voltage systems lugs and socket-outlets does not have protective conductor contact FELV circuits Used FELV source Voltage ELV Insulating of FELV circuits from LV supply FELV circuits insulated from accessible parts according Table X.1 lugs not able to enter socket-outlets of other voltage systems Socket outlets does not admit plugs of other voltage systems Socket-outlets does not have protective conductor contact Other circuits Other circuits insulated from accessible parts according Table X.1 Class II construction with equipotential bonding for protection against indirect contacts with live parts: - conductive parts are connected together TRF NO.: IEC60598_2_21A age 13 of 54 Report No.: ED S Ver.1.0

14 - test according conductive part not cause an electric shock in case of an insulation fault - equipotential bonding in master/slave applications - master luminaire provided with terminal for accessible conductive parts of slave luminaires - slave luminaire constructed as class I (4.32) Overvoltage protective devices Comply with IEC External to controlgear and connected to earth: - only in fixed luminaires - only connected to protective earth.2 (-) Terminal blocks Clause 4.6 of IEC referring to terminal blocks does not apply.3 (-) Terminals and supply connections Comply with Annex A.4 (-) Control units Forming an integral part enclosed in non-flammable insulating material tested according Securely fixed to the cable Electronic control device comply with IEC LED driver comply with IEC (-) Mechanical strength a) Rigid rope lights 1) ull test: force 60 N 2) Torque test: torque 0,15 Nm b) Flexible rope lights 1) ull test: force 60 N 2) Torque test: torque 0,15 Nm 3) Cylinder times at 25 C ± 2 C For rope lights having an I number over X0 Additionally: Cylinder times at -15 C ± 2 C 4) Mandrel of between 4 and 5 times the diameter of test piece c) Impact test at low temperature of -15 C ± 5 C TRF NO.: IEC60598_2_21A age 14 of 54 Report No.: ED S Ver.1.0

15 21.8 (11) CREEAGE DISTANCES AND CLEARANCES 21.8 (11.2) Creepage distances and clearances... : See Table 21.8 (11.2) Working voltage (V)... : 110V Rated pulse voltage (kv)... : -- Voltage form... : Sinusoidal Non-sinusoidal TI... : < 600 > 600 Impulse withstand category (Normal category II) (Category III Annex U) Category II Category III (14) SCREW TERMINALS Separately approved; component list (see Annex 1) art of the luminaire (see Annex 3) (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS Separately approved; component list... : (see Annex 1) art of the luminaire... : (see Annex 4) (5) EXTERNAL AND INTERNAL WIRING (5.2) Supply connection and external wiring (5.2.1) Means of connection... : Supply cord Outdoor luminaire has not VC insulated external wiring if not class III or SELV 25 V a.c./60 V d.c. or protected from outdoor environment (5.2.2) Type of cable... : See ANEEX 1 Nominal cross-sectional area (mm²)... : See ANEEX 1 Cables equal to IEC or IEC (5.2.3) Type of attachment, X, Y or Z Type Y (5.2.5) (5.2.6) Type Z not connected to screws Cable entries: - suitable for introduction TRF NO.: IEC60598_2_21A age 15 of 54 Report No.: ED S Ver.1.0

16 (5.2.7) (5.2.8) (5.2.9) (5.2.10) ( ) ( ) ( ) - adequate degree of protection Cable entries through rigid material have rounded edges Insulating bushings: - suitably fixed - material in bushings - material not likely to deteriorate - tubes or guards made of insulating material Locking of screwed bushings Cord anchorage: - covering protected from abrasion - clear how to be effective - no mechanical or thermal stress - no tying of cables into knots etc. - insulating material or lining Cord anchorage for type X attachment: a) at least one part fixed b) types of cable c) no damaging of the cable d) whole cable can be mounted e) no touching of clamping screws f) metal screw not directly on cable g) replacement without special tool Glands not used as anchorage Labyrinth type anchorages Adequate cord anchorage for type Y and type Z attachment Tests: - impossible to push cable; unsafe - pull test: 25 times; pull (N)... : 60N - torque test: torque (Nm)... : 0.25Nm - displacement 2 mm 0.7mm<2.0mm TRF NO.: IEC60598_2_21A age 16 of 54 Report No.: ED S Ver.1.0

17 (5.2.11) (5.2.12) (5.2.13) (5.2.14) (5.2.16) (5.2.17) (5.2.18) - no movement of conductors - no damage of cable or cord - function independent of electrical connection External wiring passing into luminaire Looping-in terminals Wire ends not tinned Wire ends tinned: no cold flow Mains plug same protection Class III luminaire plug No unsafe compatibility Appliance inlets (IEC 60320) Installation couplers (IEC 61535) Other appliance inlet or connector according relevant IEC standard No standardized interconnecting cables properly assembled Used plug in accordance with - IEC other standard (5.3) Internal wiring (5.3.1) ( ) Internal wiring of suitable size and type Through wiring - not delivered/ mounting instruction - factory assembled - socket outlet loaded (A)... : - temperatures... : (see Annex 2) Green-yellow for earth only Internal wiring connected directly to fixed wiring Cross-sectional area (mm²)... : Insulation thickness TRF NO.: IEC60598_2_21A age 17 of 54 Report No.: ED S Ver.1.0

18 ( ) ( ) ( ) ( ) ( ) (5.3.2) (5.3.3) (5.3.4) (5.3.5) (5.3.6) (5.3.7) Extra insulation added where necessary Internal wiring connected to fixed wiring via internal current-limiting device Adequate cross-sectional area and insulation thickness Double or reinforced insulation for class II Conductors without insulation SELV current-carrying parts Insulation thickness other than VC or rubber Sharp edges etc. No moving parts of switches etc. Joints, raising/lowering devices Telescopic tubes etc. No twisting over 360 Insulating bushings: - suitable fixed - material in bushings - material not likely to deteriorate - cables with protective sheath Joints and junctions effectively insulated Strain on internal wiring Wire carriers Wire ends not tinned Wire ends tinned: no cold flow.2 (-) Cables for rope lights Type of cable... : Cables not lighter than IEC or IEC for class II rope lights TRF NO.: IEC60598_2_21A age 18 of 54 Report No.: ED S Ver.1.0

19 Cables not lighter than insulation according to of part 1 for class III rope lights Nominal cross-sectional area (mm²)... : (see Annex 1) Mechanical properties according and of part 1.3 (-) Cord anchorage test ull test 30 N 25 times on single-core cable.4 (-) lugs and cable length Splash-proof plug or permanent connection if for outdoor use Length of the cable between the plug and the connection to the rope light not less than 1,5 m.5 (-) Maximum length of extendable class II rope lights Maximum length 100 m for 0,5 mm²cable Maximum length 150 m for 0,75 mm²cable (8) ROTECTION AGAINST ELECTRIC SHOCK (8.2.1) (8.2.2) Live parts not accessible Basic insulated parts not used on the outer surface without appropriate protection Basic insulated parts not accessible with standard test finger on portable, settable and adjustable luminaires Basic insulated parts not accessible with Ø 50 mm probe from outside, other types of luminaires Lamp and starterholders in portable and adjustable luminaires comply with double or reinforced insulation requirements Basic insulation only accessible under lamp or starter replacement rotection in any position Double-ended tungsten filament lamp Insulation lacquer not reliable Double-ended high pressure discharge lamp Relevant warning according to fitted to the luminaire ortable luminaire adjusted in most unfavourable position TRF NO.: IEC60598_2_21A age 19 of 54 Report No.: ED S Ver.1.0

20 21.12 (8.2.3.a) (8.2.3.b) (8.2.3.c) (8.2.4) (8.2.5) (8.2.6) (8.2.7) Class II luminaire: - basic insulated metal parts not accessible during starter or lamp replacement - basic insulation not accessible other than during starter or lamp replacement - glass protective shields not used as supplementary insulation BC lampholder of metal in class I luminaires shall be earthed SELV circuits with exposed current carrying parts: Ordinary luminaire: - touch current... : - no-load voltage... : Other than ordinary luminaire: - nominal voltage... : ortable luminaire have protection independent of supporting surface Compliance with the standard test finger or relevant probe Covers reliably secured Discharging of capacitors 0,5 F ortable plug connected luminaire with capacitor Other plug connected luminaire with capacitor Discharge device on or within capacitor Discharge device mounted separately (12) ENDURANCE TEST AND THERMAL TEST (-) If I > I 20 relevant test of (12.4), (12.5) and (12.6) after (9.2) before (9.3) specified in (12.3) Endurance test: - mounting-position... : Acc. to user manual - test temperature ( C)... : 35 C - total duration (h)... : 240h - supply voltage: Un factor; calculated voltage (V)... : 264V TRF NO.: IEC60598_2_21A age 20 of 54 Report No.: ED S Ver.1.0

21 - lamp used... : Integral LED (12.3.2) (12.4) (12.5) (12.6) (12.6.1) (12.6.2) (12.7) (12.7.1) ( ) After endurance test: - no part unserviceable - luminaire not unsafe - no damage to track system - marking legible - no cracks, deformation etc. Thermal test (normal operation) (see Annex 2) Thermal test (abnormal operation) (see Annex 2) Thermal test (failed lamp control gear condition): Through wiring or looping-in wiring loaded by a current of (A)... : - case of abnormal conditions... : - electronic lamp control gear - measured winding temperature ( C): at 1,1 Un... : - measured mounting surface temperature ( C) at 1,1 Un... : - calculated mounting surface temperature ( C)... : - track-mounted luminaires Temperature sensing control - case of abnormal conditions... : - thermal link - manual reset cut-out - auto reset cut-out - measured mounting surface temperature ( C)... : - track-mounted luminaires Thermal test (failed lamp control gear in plastic luminaires): Luminaire without temperature sensing control Luminaire with fluorescent lamp 70W Test method or Annex W... : TRF NO.: IEC60598_2_21A age 21 of 54 Report No.: ED S Ver.1.0

22 Test according to : - case of abnormal conditions... : - Ballast failure at supply voltage (V)... : - Components retained in place after the test - Test with standard test finger after the test Test according to Annex W: - case of abnormal conditions... : ( ) ( ) (12.7.2) - measured winding temperature ( C): at 1,1 Un... : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test... : See Table (13.2.1) Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA - case of abnormal conditions... : - measured winding temperature ( C): at 1,1 Un... : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test... : See Table (13.2.1) Luminaire with short circuit proof transformers 10 VA - case of abnormal conditions... : - Components retained in place after the test - Test with standard test finger after the test Luminaire with temperature sensing control - thermal link... : Yes No - manual reset cut-out... : Yes No - auto reset cut-out... : Yes No - case of abnormal conditions... : - highest measured temperature of fixing point/ exposed part ( C):... : Ball-pressure test:... : See Table (13.2.1) (-) Test voltage TRF NO.: IEC60598_2_21A age 22 of 54 Report No.: ED S Ver.1.0

23 rovision of d) of part 1 and if class III rope lights 1,1 x rated voltage of transformer/convertor rovision of d) of part 1 and if class III rope lights 1,06 x rated voltage of transformer/convertor (-) Short-circuit test of rectifier No emission of flames or molten material or production of flammable gases and no live parts accessible when short-circuit output of the rectifier (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE (-) If I > I 20 the order of tests as specified in clause (9.2) Tests for ingress of dust, solid objects and moisture: - classification according to I... : I65 - mounting position during test... : Acc. to user manual - fixing screws tightened; torque (Nm)... : -- - tests according to clauses... : & electric strength test afterwards a) no deposit in dust-proof luminaire b) no talcum in dust-tight luminaire c) no trace of water on current-carrying parts or on insulation where it could become a hazard d) i) For luminaires without drain holes no water entry d) ii) For luminaires with drain holes no hazardous water entry e) no water in watertight luminaire f) no contact with live parts (I 2X) f) no entry into enclosure (I 3X and I 4X) f) no contact with live parts (I3X and I4X) g) no trace of water on part of lamp requiring protection from splashing water h) no damage of protective shield or glass envelope (9.3) Humidity test 48 h 25 C, 93 % RH (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH (10.2.1) Insulation resistance test TRF NO.: IEC60598_2_21A age 23 of 54 Report No.: ED S Ver.1.0

24 Cable or cord covered by metal foil or replaced by a metal rod of mm Ø... : (10.2.2) Insulation resistance (M )... : SELV - between current-carrying parts of different polarity : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts... : - Insulation bushings as described in Section 5... : Other than SELV - between live parts of different polarity... : >100M - between live parts and mounting surface... : >100M - between live parts and metal parts... : - between live parts of different polarity through action of a switch... : - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts... : - Insulation bushings as described in Section 5... : Electric strength test Dummy lamp Luminaires with ignitors after 24 h test Luminaires with manual ignitors Test voltage (V)... : SELV - between current-carrying parts of different polarity : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts... : - Insulation bushings as described in Section 5... : TRF NO.: IEC60598_2_21A age 24 of 54 Report No.: ED S Ver.1.0

25 21.15 (10.3) Other than SELV - between live parts of different polarity... : 1220V - between live parts and mounting surface... : 2440V - between live parts and metal parts... : - between live parts of different polarity through action of a switch... : - between the outer surface of a flexible cord or cable where it is clamped in a cord anchorage and accessible metal parts... : - Insulation bushings as described in Section 5... : Touch current or protective conductor current (ma) : 0.1mA (13) RESISTANCE TO HEAT, FIRE AND TRACKING (13.2.1) (13.3.1) (13.3.2) (13.4) Ball-pressure test... : See Test Table (13.2.1) Needle-flame test (10 s)... : See Test Table (13.3.1) Glow-wire test (650 C)... : See Test Table (13.3.2) roof tracking test (IEC 60112)... : See Test Table (13.4) (-) Flexible pipes of rope lights in compliance with IEC TRF NO.: IEC60598_2_21A age 25 of 54 Report No.: ED S Ver.1.0

26 21.8 (11.2) TABLES: Creepage distances and clearances Table 11.1 Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages RMS working voltage (V) not exceeding Creepage distances Required basic insulation, TI 600 0,6 0,8 1, ,5 Measured Required basic insulation, TI < 600 1,2 1,6 2, Measured Required supplementary insulation TI 600-0,8 1, ,5 Measured Required supplementary insulation TI < 600-1,6 2, Measured Required reinforced insulation - 3, Measured Clearances Required basic insulation 0,2 0,8 1, ,5 Measured Required supplementary insulation - 0,8 1, ,5 Measured Required reinforced insulation - 1, Measured Table 11.2 Minimum distances (mm) for non-sinusoidal pulse voltages TRF NO.: IEC60598_2_21A age 26 of 54 Report No.: ED S Ver.1.0

27 Rated pulse voltage (peak kv) 2,0 2,5 3,0 4,0 5,0 6,0 8,0 Required clearances 1,0 1, ,5 8 Measured Rated pulse voltage (peak kv) Required clearances Measured Rated pulse voltage (peak kv) Required clearances Measured 1. Between pins of fuse link; cr.=cl.=5.0mm(limit cr.=1.6mm, cl.=0.8mm) 2. Between L and N of fuse box: cr.=cl.=5.0mm(limit cr.=1.6mm, cl.=0.8mm) 3. Current-carrying parts and accessible parts: Cr.=cl.=6.0mm(Limit cr.=3.2mm, cl.=1.6mm) 4. Current-carrying parts and supporting surface: Cr.=cl.=6.0mm(Limit cr.=3.2mm, cl.=1.6mm) (13.2.1) TABLE: Ball ressure Test of Thermoplastics Allowed impression diameter (mm)... : 2mm Object/ art No./ Material Manufacturer/ trademark Test temperature ( C) Impression diameter (mm) Fuse box C 1.2mm CB of Fuse C 1.0mm Supplementary information: (13.3.1) TABLE: Needle-flame test (IEC ) Object/ art No./ Material Manufacturer/ trademark Duration of application of test flame (ta); (s) Ignition of specified layer Yes/No Duration of burning (tb) (s) Verdict Connector -- 10s No -- CB of Fuse -- 10s No -- CB of LED -- 10s No -- Supplementary information: (13.3.2) TABLE: Glow-wire test (IEC ) TRF NO.: IEC60598_2_21A age 27 of 54 Report No.: ED S Ver.1.0

28 Glow wire temperature... : 650 C Object/ art No./ Material Manufacturer/ trademark Ignition of specified layer Yes/No Duration of burning (tb) (s) Fuse box -- No 0 Diffuser enclosure -- No 0 Any flame or glowing of the sample extinguished within 30 s of withdrawing the glow-wire, and any burning or molten drop did not ignite the underlying parts (Yes/No)... : Supplementary information: Verdict Yes (13.4) TABLE: roof tracking test (IEC 60112) Test voltage TI... : 175 V Object/ art No./ Material Manufacturer/ trademark Withstand 50 drops without failure on three places or on three specimens Diffuser enclosure -- Yes Yes Yes Supplementary information: Verdict TRF NO.: IEC60598_2_21A age 28 of 54 Report No.: ED S Ver.1.0

29 ANNEX A Requirements for interconnecting connectors for use in rope lights This Annex A consist relevant requirements and modifications of IEC Classification according to protection against electric shock Only enclosed connectors 5.3 Classification according to the style of connector Only free connectors 5.4 Classification according to additional characteristics of connectors According b), d), e), f), h), and j) Identification According a) and b) Non accessibility of live parts Test with test finger on class II rope lights olarisation Improper connection of mating parts is prevented No unsafe compatibility between connectors for class II and class III rope lights of the same manufacturer Male part of class III rope lights not make contact in the female contact of low voltage connectors (e.g. IEC 60320) Manufacturer designed connectors, no unsafe compatibility with systems according IEC and IEC and national domestic plug and socketoutlet systems in the country where the rope light is placed on the market Connection of conductors Cross sectional area of the contact making part of the interconnecting coupler not less than the corresponding conductor in the interconnected cable 6.10 Design of a CBC Adequate breaking capacity Female part at the end of the rope light, other than ordinary, provided with sealing device securely fixed to the coupler 6.13 Dielectric strength Test according clause of this standard Electrical endurance (CBC) Meet the specified breaking capacity Number of cycles 50 TRF NO.: IEC60598_2_21A age 29 of 54 Report No.: ED S Ver.1.0

30 Test according Bendings (non-rewirable connectors) Meet the specified number of bendings Number of cycles 1000 Test according Cable clamp Test according clause.3 of this standard TRF NO.: IEC60598_2_21A age 30 of 54 Report No.: ED S Ver.1.0

31 ANNEX 1: components object/part No. External wire Fuse box Rubber ring CB of Fuse CB of LED Varistor Fuse Connector LED Diffuser enclosure code manufacturer/ trademark B C C B B B B B C C Yuyao Jingyi Electronics Co., Ltd. Dongguan Long Ran lastic Electronic Co., Ltd. Dongguan Long Ran lastic Electronic Co., Ltd. SHENZHEN HENGLONGXIN ELECTRONICS TECHNOLOGY CO LTD HUIZHOU CHUANLIAN ELECTRONIC TECHNOLOGY CO LTD CERGLASS MFG INC SUNNY EAST ENTERRISE CO LTD SHENZHEN CHOGORI TECHNOLOGY CO LTD ShenZhen JuFei Optoelectronics Co., Ltd. KINGFA SCI & TECH CO LTD type/model technical data standard mark(s) of conformity H05RN-F 2x1.0mm2 -- VDE Q7103 I65, 130 C -- O- ring(q7103) Rubber, 130 C -- Tested with appliance Tested with appliance HLX-D 130 C, V-0 -- UL E CL-Y 105 C, V-0 -- UL E D471K V, 0.4W -- VDE CFD 250V, 6.3A -- VDE (female), (male) 250V/10A, 40~105 C I mA, V -- VC-1018 V-0, any color UL E TUV B Tested with appliance Tested with appliance The codes above have the following meaning: A - The component is replaceable with another one, also certified, with equivalent characteristics B - The component is replaceable if authorised by the test house C - Integrated component tested together with the appliance D- Alternative component TRF NO.: IEC60598_2_21A age 31 of 54 Report No.: ED S Ver.1.0

32 ANNEX 2 TABLE: Temperature measurements, thermal tests of Section 12 art Type reference... : x-glo v Lamp used... : Integral LED Lamp control gear used... : See annex 1 Mounting position of luminaire... : As normal used according instruction manual Supply wattage (W)... : 554.5W Supply current (A)... : 5.05A Calculated power factor... : Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : During the sample tested under fault condition, the LED driver shut down or fuse open - test 1: rated voltage... : -- - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : Temperature measurements, ( C) Clause 12.4 normal TRF NO.: IEC60598_2_21A age 32 of 54 Report No.: ED S Ver.1.0 1,06 times rated voltage Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Fuse box plastic enclosure outside Ref Fuse box plastic enclosure inside Ref ZV CB of Fuse Ref Connector Ref Input wire Input Connector outside Ref Input Connector inside Ref CB of LED, nearest to center LED Diffuser outside Ref

33 Diffuser inside Ref Mounting surface Ambient Supplementary information: TRF NO.: IEC60598_2_21A age 33 of 54 Report No.: ED S Ver.1.0

34 ANNEX 4 Screwless terminals (part of the luminaire) (15) SCREWLESS TERMINALS (15.2) Type of terminal... : Rated current (A)... : (15.3.1) Material (15.3.2) Clamping (15.3.3) Stop (15.3.4) Unprepared conductors (15.3.5) ressure on insulating material (15.3.6) Clear connection method (15.3.7) Clamping independently (15.3.8) Fixed in position ( ) Conductor size Type of conductor (15.5) Terminals and connections for internal wiring (15.5.1) Mechanical tests ( ) ull test spring-type terminals (4 N, 4 samples)... : ( ) ull test pin or tab terminals (4 N, 4 samples)... : Insertion force not exceeding 50 N ( ) ermanent connections: pull-off test (20 N) (15.5.2) Electrical tests Voltage drop (mv) after 1 h (4 samples)... : Voltage drop of two inseparable joints Number of cycles: Voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : Voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : After ageing, voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : After ageing, voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : (15.6) Terminals and connections for external wiring (15.6.1) Conductors Terminal size and rating TRF NO.: IEC60598_2_21A age 34 of 54 Report No.: ED S Ver.1.0

35 Mechanical tests ( ) ull test spring-type terminals or welded connections (4 samples); pull (N)... : ( ) ull test pin or tab terminals (4 samples); pull (N)... : (15.6.3) Electrical tests Tests according in IEC ( ) ( ) TABLE: Contact resistance test / Heating tests Voltage drop (mv) after 1 h terminal voltage drop (mv) Voltage drop of two inseparable joints Voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Supplementary information: TRF NO.: IEC60598_2_21A age 35 of 54 Report No.: ED S Ver.1.0

36 Attachment No.1 EN (4) GENERAL REQUIREMENTS - (4) Insulation materials according requirements in Annex N of IEC (4) Compliance of independent controlgear enclosure with IEC (4) Built-in electronic controlgear with double or reinforced insulation comply with Annex O of IEC (4) SELV controlgear comply with Annex L of IEC (see Annex N) (see Annex O) (see Annex L) 6 (6) CLASSIFICATION Built-in controlgear... : Yes No Independent controlgear... : Yes No Integral controlgear... : Yes No 7 (7) MARKING 7.1 (7.1) Mandatory markings (other than integral miscellaneous electronic circuits) a) mark of origin b) model number or type reference d) correlation between interchangeable parts and controlgear marked e) rated supply voltage (V) supply frequency (Hz) supply current (A) f) earthing symbol k) wiring diagram l) value of tc alternative ta 7.1 (-) - control terminals identified, if applicable - (7.2) Marking durable and legible Rubbing 15 s water, 15 s petroleum; marking legible 7.2 (7.1) Information to be provided, if applicable: h) declaration on protection against accidental contact i) cross-section of conductors (mm²) j) number, type and wattage of lamp(s) - (7.2) Marking durable and legible TRF NO.: IEC60598_2_21A age 36 of 54 Report No.: ED S Ver.1.0

37 Attachment No.1 EN Rubbing 15 s water, 15 s petroleum; marking legible 8 (10) ROTECTION AGAINST ACCIDENTAL CONTACT WITH LIVE ARTS - (10.1) Controlgear protected against accidental contact with live parts Rely upon final luminaries - (A2) Voltage measured with 50 k (see Annex A) - (A3) Voltage > 35 V r.m.s. or > 60 V d.c. or protective impendance device - (10.1) Lacquer or enamel not used for protection or insulation Adequate mechanical strength on parts providing protection - (10.2) Capacitors > 0,5 F: voltage after 1 min (V): < 50 V... : (see Annex A) - (10.3) Controlgear providing SELV Accessible conductive parts are insulated from live parts by double or reinforced insulation in SELV controlgear No connection between output circuit and the body or protective earthing curcuit No possibility of connection between output circuit and the body or protective earthing circuit through other conductive parts SELV outputs separated by at least basic insulation ELV conductive parts insulated as live parts Tests according Annex L of IEC (10.4) Accessible conductive parts in SELV circuits Output voltage under load 25 V r.m.s. or 60 V d.c. If output voltage > 25 V r.m.s. or > 60 V d.c.; No load output 35 V peak or 60 V d.c and touch current does not exceed 0,7 ma (peak) or 2 ma d.c.... : One conductive part is insulated if output voltage or current exceeding the values above and withstand test voltage 500 V Double or reinforced insulation bridged by appropriate and at least two resistors or two Y2 capacitors or one Y1 capacitor Y1 or Y2 capacitors comply with IEC TRF NO.: IEC60598_2_21A age 37 of 54 Report No.: ED S Ver.1.0

38 Attachment No.1 EN Resistors comply with test (a) in 14.1 of IEC (8) TERMINALS - (8) Screw terminals according section 14 of IEC : Separately approved; component list (see Annex 1) art of the controlgear (see Annex 2) Screwless terminals according section 15 of IEC : Separately approved; component list (see Annex 1) art of the controlgear (see Annex 3) 10 (9) ROVISION FOR ROTECTIVE EARTHING - (9.1) rovisions for protective earthing Terminal complying with clause 9 Locked against loosening and not possible to loosen by hand Not possible to loosen clamping means unintentionally on screwless terminals Earthing via means of fixing Earthing terminal only used for the earthing of the control gear All parts of material minimizing the danger of electrolytic corrosion Made of brass or equivalent material Contact surface bare metal - (9.2) rovision for functional earthing Comply with clause 8 and (9.3) Earth contact via the track on the printed board Test with a current of 25 A between earthing terminal and each of the accessible metal parts; measured resistance ( ) at 10 A according of IEC : < 0,5... : - (9.4) Earthing of built-in lamp controlgear Earth by means of fixing to earthed metal of luminaire in compliance of 7.2 of IEC Earthing terminal only for earthing the built-in controlgear - (9.5) Earthing via independent controlgear TRF NO.: IEC60598_2_21A age 38 of 54 Report No.: ED S Ver.1.0

39 Attachment No.1 EN (9.5.1) Earth connection to other equipment Looping or through connection, conductor min. 1,5 mm²and of copper or equivalent rotective earthing wires in line with and clause 7 - (9.5.2) Earthing of the lamp compartments powered via the independent lamp controlgear Test with a current of 25 A between input and output earth terminals; measured resistance ( ) between earthing terminal and each of the accessible metal parts at 10 A according of IEC : < 0,5... : Output earthing terminal marked as in 7.1 t) of IEC (11) MOISTURE RESISTANCE AND INSULATION After storage 48 h at 91-95% relative humidity and C measuring of insulation resistance with d.c. 500 V (M ): For basic insulation 2 M... : For double or reinforced insulation 4 M... : Between primary and secondary circuits in controlgear providing SELV, values in Annex L in IEC Between different pole of input terminal: 100 M 12 (12) ELECTRIC STRENGTH - (12) Immediately after clause 11 electric strength test for 1 min Basic insulation for SELV, test voltage 500 V Working voltage 50 V, test voltage 500 V Working voltage > 50 V 1000 V, test voltage (V): Basic insulation, 2U V 1220V Supplementary insulation, 2U V Double or reinforced insulation, 4U V No flashover or breakdown Solid or thin sheet insulation for double or reinforced insulation fulfil the requirements in Annex N in IEC (14) FAULT CONDITIONS - (14) When operated under fault conditions the controlgear: TRF NO.: IEC60598_2_21A age 39 of 54 Report No.: ED S Ver.1.0

40 Attachment No.1 EN does not emit flames or molten material - does not produce flammable gases - protection against accidental contact not impaired Thermally protected controlgear does not exceed the marked temperature value Fault conditions: capacitors, resistors or inductors without proof of compliance with relevant specifications have been short-circuited or disconnected - (14.1) Short-circuit of creepage distances and clearances if less than specified in clause 16 in art 1 (except between live parts and accessible metal parts) Creepage distances on printed boards less than specified in clause 16 in art 1 provided with coating according to IEC (see appended table) (see appended table) - (14.2) Short-circuit or interruption of semiconductor devices (see appended table) - (14.3) Short-circuit across insulation consisting of lacquer, enamel or textile (see appended table) - (14.4) Short-circuit across electrolytic capacitors (see appended table) - (14.5) After the tests has been carried out on three samples: The insulation resistance 1 M... : No flammable gases No accessible parts have become live During the tests, a five-layer tissue paper, where the test specimen is wrapped, does not ignite - (14.6) Relevant fault condition tests with high-power supply 15 (15) CONSTRUCTION - (15.1) Wood, cotton, silk, paper and similar fibrous material Wood, cotton, silk, paper and similar fibrous material not used as insulation - (15.2) rinted circuits rinted circuits used as internal connections complies with clause 14 - (15.3) lugs and socket-outlets used in SELV or ELV circuits No dangerous compatibility between output socketoutlet and a plug for socket-outlets for input circuit in relation to installation rules, voltages and frequencies lugs and socket-outlets for SELV comply with IEC and IEC TRF NO.: IEC60598_2_21A age 40 of 54 Report No.: ED S Ver.1.0

41 Attachment No.1 EN lugs and socket-outlets for SELV 3 A, 25 V r.m.s. or 60 V d.c. and 72 W comply with IEC and IEC or: - plugs not able to enter socket-outlets of other standardised system - socket-outlets not admit plugs of other standardised system - socket-outlets without protective earth 16 (16) CREEAGE DISTANCES AND CLEARANCES - (16) Creepage distances and clearances according to Table 3 and 4, as appropriate Controlgears providing SELV comply with L.1 in Annex L Insulating lining of metallic enclosures Basic insulation on printed boards tested according to clause 14 Distances subjected to both sinusoidal voltage as non-sinusoidal pulses not less than value in either Table 3 or 4 Creepage distances not less than minimum clearance 17 (17) SCREWS, CURRENT-CARRYING ARTS AND CONNECTIONS Screws, current-carrying parts and connections in compliance with IEC (clause numbers between parentheses refer to IEC ) (4.11) Electrical connections (4.11.1) Contact pressure (4.11.2) Screws: - self-tapping screws - thread-cutting screws (4.11.3) Screw locking: - spring washer - rivets (4.11.4) Material of current-carrying parts (4.11.5) No contact to wood or mounting surface (4.11.6) Electro-mechanical contact systems (4.12) Mechanical connections and glands (4.12.1) Screws not made of soft metal TRF NO.: IEC60598_2_21A age 41 of 54 Report No.: ED S Ver.1.0

42 Attachment No.1 EN Screws of insulating material Torque test: torque (Nm); part... : Torque test: torque (Nm); part... : Torque test: torque (Nm); part... : (4.12.2) Screws with diameter < 3 mm screwed into metal (4.12.4) Locked connections: - fixed arms; torque (Nm)... : - lampholder; torque (Nm)... : - push-button switches; torque 0,8 Nm... : (4.12.5) Screwed glands; force (Nm)... : 18 (18) RESISTANCE TO HEAT, FIRE AND TRACKING - (18.1) Ball-pressure test: - part tested; temperature ( C)... : See part - part tested; temperature ( C)... : - (18.2) Test of printed boards: - part tested... : See part - part tested... : - (18.3) Glow-wire test (650 C): - part tested... : See part - part tested... : - (18.4) Needle flame test (10 s): - part tested... : See part - part tested... : - (18.5) Tracking test: - part tested... : See part - part tested... : 19 (19) RESISTANCE TO CORROSION - test according of IEC adequate varnish on the outer surface 20 (-) ANNEXES Comply with appropriate annexes of IEC (see Annexes) TRF NO.: IEC60598_2_21A age 42 of 54 Report No.: ED S Ver.1.0

43 Attachment No.1 EN TABLE: tests of fault conditions art Simulated fault Hazard Varistor S-C, fuse open NO TRF NO.: IEC60598_2_21A age 43 of 54 Report No.: ED S Ver.1.0

44 Attachment No.1 EN (16) TABLES: Creepage distances and clearances Table 3 Minimum distances (mm) for a.c. (50/60 Hz) sinusoidal voltages RMS working voltage (V) not exceeding Creepage distances Required basic insulation, TI 600 0,6 0,8 1, ,5 Measured Required basic insulation, TI < 600 1,2 1,6 2, Measured 5.0 Required supplementary insulation TI 600-0,8 1, ,5 Measured Required supplementary insulation TI < 600-1,6 2, Measured Required reinforced insulation - 3, Measured 5.0 Clearances Required basic insulation 0,2 0,8 1, ,5 Measured 5.0 Required supplementary insulation - 0,8 1, ,5 Measured Required reinforced insulation - 1, Measured 5.0 Table 4 Minimum distances (mm) for non-sinusoidal pulse voltages Rated pulse voltage (peak kv) 2,0 2,5 3,0 4,0 5,0 6,0 8,0 Required clearances 1,0 1, ,5 8 Measured Rated pulse voltage (peak kv) Required clearances Measured Rated pulse voltage (peak kv) Required clearances Measured TRF NO.: IEC60598_2_21A age 44 of 54 Report No.: ED S Ver.1.0

45 Attachment No.1 EN A ANNEX A - TEST TO ESTABLISH WHETHER A CONDUCTIVE ART IS A LIVE ART WHICH MAY CAUSE AN ELECTRIC SHOCK A.1 Comply with A.2 or A.3 A.2 Voltage 35 V peak or 60 V d.c... : A.3 If voltage > 35 V r.m.s. or > 60 V d.c. or protective impendance device; touch current does not exceed 0,7 ma (peak) or 2 ma d.c.... : Comply with Annex G of IEC C ANNEX C ARTICULAR REQUIREMENTS FOR ELECTRONIC LAM CONTROLGEAR WITH MEANS OF ROTECTION AGAINST OVERHEATING C3 GENERAL REQUIREMENTS C3.1 Thermal protection means integral with the controlgear, protected against mechanical damage Renewable only by means of a tool If function depending on polarity, for cord-connected equipment protection means in both leads Thermal links comply with IEC Electrical controls comply with IEC C3.2 No risk of fire by breaking (clause C7) C5 CLASSIFICATION a) automatic resetting type b) manual resetting type c) non-renewable, non-resetting type d) renewable, non-resetting type e) other type of thermal protection; description.. : C6 MARKING C6.1 Symbol for temperature declared thermally protected controlgear C6.2 Declaration of the type of protection provided C7 LIMITATION OF HEATING C7.1 reselection test: Test sample placed for at least 12 h in an oven having temperature (tc - 5) K No operation of the protection device C7.2 Functioning of protection means: TRF NO.: IEC60598_2_21A age 45 of 54 Report No.: ED S Ver.1.0

46 Attachment No.1 EN Normal operation of the sample in a test enclosure according to Annex D at an ambient temperature such that (tc +0; -5) C is obtained No operation of the protection device Introducing of the most onerous test condition determined during test of clause 14 Output of windings connected to the mains supply short-circuited, and other part of the controlgear operated under normal conditions Increasing of the current through the windings continuously until operation of the protection means Continuous measuring of the highest surface temperature Controlgear according to C5 a) or C5 e) operated until stable conditions are achieved Automatic-resetting thermal protectors working 3 times Controlgear according to C5 b) working 6 times Controlgear according to C5 c) and C5) d) working once Highest temperature does not exceed the marked value Any overshoot of 10% over the marked value within 15 min D ANNEX D REQUIREMENTS FOR CARRY OUT THE HEATING TESTS OF THERMALLY ROTECTED LAM CONTROLGEAR Tests in C7 performed in accordance with Annex D, if applicable E ANNEX E USE OF CONSTANT S OTHER THAN 4500 IN t w TESTS Comply with tests according Annex E, if applicable F ANNEX F - DRAUGHT-ROOF ENCLOSURE Draught-proof enclosure in accordance with the description Dimensions of the enclosure Other design; description TRF NO.: IEC60598_2_21A age 46 of 54 Report No.: ED S Ver.1.0

47 Attachment No.1 EN H ANNEX H - TESTS All tests performed in accordance with the advice given in Annex H, if applicable I ANNEX I - ADDITIONAL REQUIREMENTS FOR BUILT-IN MAGNETIC BALLASTS WITH DOUBLE OR REINFORCED INSULATION Comply with tests according Annex I, if applicable TRF NO.: IEC60598_2_21A age 47 of 54 Report No.: ED S Ver.1.0

48 Attachment No.2 EN Clause Requirement Test Result Remark Verdict 13.2 Module withstands overpower condition >15 min. Module with automatic protective device or power limiter, test performed 15 min. at limit. During the tests, tissue paper, spread below module, does not ignite TRF NO.: IEC60598_2_21A age 48 of 54 Report No.: ED S Ver.1.0

49 Attachment No.3 IEC Clause Requirement Test Result Remark Verdict Item Tests according to IEC/TR 62778:2014 Symb Units Result Remark ol Correlated colour temperature CCT K / / x/y colour coordinates / / Blue light hazard radiance LB W/(m2 sr1) 33 / Blue light hazard irradiance EB W/m2 / / Luminance L cd/m e+004 / Illuminance E lx 321 / Supplementary information: TRF NO.: IEC60598_2_21A age 49 of 54 Report No.: ED S Ver.1.0

50 ictures Figure 1: Overview for model x-glo v Figure 2: Driver overview for model x-glo v TRF NO.: IEC60598_2_21A age 50 of 54 Report No.: ED S Ver.1.0

51 ictures Figure 3: Driver view for model x-glo v Figure 4: Driver front view for model x-glo v TRF NO.: IEC60598_2_21A age 51 of 54 Report No.: ED S Ver.1.0

52 ictures Figure 5: Driver rear view for model x-glo v Figure 6: Connector view for model x-glo v TRF NO.: IEC60598_2_21A age 52 of 54 Report No.: ED S Ver.1.0

53 ictures Figure 7: Connector view for model x-glo v Figure 8: Input view for model x-glo v TRF NO.: IEC60598_2_21A age 53 of 54 Report No.: ED S Ver.1.0

54 ictures Figure 9: The end view for model x-glo v ===================================END OF REORT============================== TRF NO.: IEC60598_2_21A age 54 of 54 Report No.: ED S Ver.1.0

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements Section 1: Fixed general purpose luminaires Report Number.... : 64.140.11.02922.03 Date of issue... : 2015-02-02 Total number of pages...

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total

More information

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :

More information

Page 1 of 27 Report No. : HT15DR LVD Test Report

Page 1 of 27 Report No. : HT15DR LVD Test Report age 1 of 27 LVD Test Report EN60598-1&EN60598-2-1 art 1:General requirement and tests art 2: articular requirments Section One Fixed general purpose luminaires Report reference No.......: HT15DR-120321

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires age 1 of 40 TEST REORT IEC 60598-2-2 Luminaires art 2: articular requirements Section 2: Recessed luminaires Report Number.... : 7040216100405-00 Date of issue... : 2016-11-18 Total number of pages...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Number.... : 17041854 001 Date of

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,

More information

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REORT Luminaires art 2.1: articular requirements Fixed general purpose luminaires Accredited for compliance with ISO/IEC 17025 Report Reference No.... : S17031 Compiled by (+ signature)... : Yongchan

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT) Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB13035196 Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Test Report issued under the responsibility of: Studio Oleandri - Milano TEST REPORT IEC 60598-2-1 Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Report Number...

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires TEST REORT EN 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No...: 3007562.50-QUA/LI Date of issue...: 2011-03-28 Total number of pages...

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China Summary of testing: Tests performed (name of test and test clause): The submitted samples were found to comply with the requirements of: -- E 60598-2-2:2012 -- E 60598-1:2008+A11:2009 Testing location:

More information

EN : MEASUREMENT AND TEST REPORT For

EN : MEASUREMENT AND TEST REPORT For E 60598-1: 2004 MEASUREMET AD TEST REORT For LOGSTAR LIGHTIG GROU TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, China Model:LS-T8-T600S1,LS-T8-T900S1,LS-T8-T1200S1,LS-T8-T1500S1,LS-T8-M600S1,

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No....: TGM-VA EE32453 SFT Date of issue...

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 1540-44-I Date of issue... : 2016-09-01

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT IEC LED modules for general lighting Safety specifications Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant

More information

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires TEST REORT Luminaires art 1: General requirements and Tests art 2: articular requirements - Section 4: ortable general purpose luminaires Report Reference o: Tested by: T1321-21-12 Urs Wyttenbach Approved

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 6011995.50 Date of issue... :

More information

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting TEST REORT AS/ZS 60598.2.3:2015 Luminaires art 2.3: articular requirements Luminaires for road and street lighting Report Reference o.... : RSZ170419551-03 Compiled by (+ signature)... : Andy Fu Approved

More information

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598.

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598. Doc Id: AS/ZS60598.2.1:2014+A1 Report o: 0803BSS-61900_59821 age 1 of 49 Compliance Testing Report for Australian/ew Zealand Standard AS/ZS 60598.2.1: 2014 Inc Amendment 1 in conjunction with AS/ZS60598.1:2013

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CGZ3150109-00114-L-F GZ test site: A101, o.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China,

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China, Shenzhen BST Technology Co., Ltd Shenzhen Merrylux Optoelectronics co., ltd TEST REORT repared For: Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan,

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):

More information

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007 Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,

More information

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment):

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment): age 3 of 90 Report No.: 17052930 001 List of Attachments (including a total number of pages in each attachment): Attachment 1: 12 pages of photos. Summary of testing: Tests performed (name of test and

More information

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED age 1 of 47 Report o. R011501451I SAA TEST REORT On Behalf of AOK LED LIGHT COMAY LIMITED LED Street Light Model: AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL,

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing

More information

Test report: 13/ Date January 20 th,2014 Page 1 of 52

Test report: 13/ Date January 20 th,2014 Page 1 of 52 LGAI LGAI Technological Center, S.A. Campus de la UAB Apartado de Correos 18 E - 08193 Bellaterra (Barcelona) T +34 93 567 20 00 F +34 93 520 20 01 www.appluslaboratories.com TEST REORT Test report: 13/31705080

More information

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires Report Reference o....: Compiled by (+ signature)...: Approved by (+ signature)... : TEST REORT AS/ZS 60598.2.1 Luminaires art 2: articular requirements: Fixed general purpose luminaires RSZ160822550-03

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

Page 3 of 32 Report No Summary of testing:

Page 3 of 32 Report No Summary of testing: age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.

More information

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REPORT Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Report Reference No...: HZ10120073-001 ate of issue...:

More information

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches Test Report issued under the responsibility of: TEST REPORT Switches for appliances Part 2-1: Particular requirements for cord switches Report Reference No.... : SH11080876-001 Date of issue... : 2012-02-23

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016

More information

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd age 1 of 55 Report o. R011607605S-1 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co.,Ltd LED Flood Light Model: QH-FLXH01-50W, QH-FLXH02-100W, QH-FLXH03-150W, QH-FLXH04-200W,

More information

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd.

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd. TEST REORT Reference o.... : WTF15F0730677S Applicant... : Foshan anhai Vorld Lighting Co., Ltd. Address... : 18th west Taoyuan Road, Shishan Town, anhai District, Foshan City, Guangdong rovince Manufacturer...

More information

Test Report No EEC12-03/MLM dated 27 MAR 2012

Test Report No EEC12-03/MLM dated 27 MAR 2012 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD SB te Ltd. In addition, this report is

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 70.410.14.127.01-01 Date of issue... : 2014-07-03 Total number of pages... 61

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

SHA-001 Date of issue...: Total number of pages Report Reference No...:

SHA-001 Date of issue...: Total number of pages Report Reference No...: TEST REORT lugs and socket-outlets for household and similar purposes art 2-1: General requirements on plugs and portable socket-outlets Report Reference No....: 130600884SHA-001 Date of issue...: 2013-07-09

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

Remark: Whether parts of tests for the product have been subcontracted to other labs:

Remark: Whether parts of tests for the product have been subcontracted to other labs: Reference o.: WTS16S1166817S age 2 of 60 Test item description...: Trademark...: Model and/or type reference...: AU-BD350VA Rating(s)... : 220-240V~, 50Hz, Max. 350VA, Min 10VA Remark: Whether parts of

More information

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests Test Report issued under the responsibility of: Report Reference o...: age 1 of 11 TEST REORT IEC 60968 and/or E 60968 Luminaires art 1: General Requirements And Tests GTSS12060031301 Date of issue...:

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 66 Test Report issued under the responsibility of NCB: NCB TÜV SÜD SB 1 Science ark Drive, 118221 Singapore Singapore TEST REORT IEC 61347-2-13 art 2: articular requirements: Section Thirteen

More information

Test Report No EEC12-02/MLM dated 29 MAR 2012

Test Report No EEC12-02/MLM dated 29 MAR 2012 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD SB te Ltd. In addition, this report is

More information

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires Test Report issued under the responsibility of: TEST REORT E 60598-2-2: 1996 LUMIAIRES --- SAFETY--- ART 2-2: articular requirements- Recessed luminaires Report reference o...: GTSS12080044101 Compiled

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of TEST REORT IEC 60884-1 lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 2228900-1520-0001/175202

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools art 2: articular requirements for drills and impact drills Report reference No.... : 3130837.50A

More information

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050805SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan Road,

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances - age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro

More information

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark :

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark : CERTIFICATE of Conformity Reference o. : LCS1702161029S 001 Applicant : LOKOLED Address : Kitmanstraat 14 1812 M Alkmaar The etherlands Trademark : /A roduct : LED Downlight Model(s) : (see attached) arameters

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of GUAGDOG EAST OWER CO., LTD. Uninterruptible ower Supply Model(s): EA99300,EA99250,EA99200 repared For : GUAGDOG EAST OWER CO., LTD. o.6 orthern Industry

More information

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82 age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050811SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For : SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan

More information