Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)

Size: px
Start display at page:

Download "Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)"

Transcription

1 Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR Serial o. : BR-FL-10W, BR-FL-20W, BR-FL-30W, BR-FL-50W, BR-FL-70W, BR-FL-100W, BR-FL-120W, BR-FL-140W, BR-FL-20W-01-IR, BR-FL-30W-01-IR, BR-FL-50W-01-IR, BR-FL-10W-01-RGB, BR-FL-20W-01-RGB, BR-FL-30W-01-RGB, BR-FL-60W-01-RGB. Brand ame : BREE LIGHTIG Issue Date : Standards : E :2003 E : A11: 2009 Conclusions : ASS This report shows that the product technically complies with the Council LVD Directive 2006/95/EC requirements. Report by : Fanny Chen Checked by : Approved by : This test report is valid for above tested sample only and shall not be reproduced in part without written approval of the laboratory. 10/F., A Block, Jiada R & D Bldg., o.5 Songpingshan Road, Science & Technology ark, anshan District, Shenzhen, China Tel: Fax:

2 age: 2 of 33 TEST REORT IEC/E Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference o.... : TB-LVD Date of issue... : Feb. 25, 2013 Total number of pages Testing Laboratory... : Shenzhen Toby Technology Co., Ltd. Address... : 10/F., A Block, Jiada R & D Bldg., o.5 Songpingshan Road, Science & Technology ark, anshan District, Shenzhen, China Applicant s name... : BREE LIGHTIG Co., LIMITED Address... : Bld. M & J, Maoyuan Industrial, Zhangkenjing Xiawei, Guanlan, Bao an, Shenzhen, China Test specification: Standard... : Test procedure... : LVD on-standard test method.: /A IEC :2002 used in conjunction with E :2003+A1: 2011 used in conjunction with IEC :2008 E : A11: 2009 Test Report Form o.... : IEC/E 60598_2_3G Test Report Form(s) Originator: Intertek Semko AB Master TRF... : Copyright 2009 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an CB in accordance with IECEE 02. Test item description...: Led Flood Light Trade Mark : BREE LIGHTIG Manufacturer : Same as applicant Factory : Same as applicant Model/Type reference : BR-FL-10W -01-IR (See the page 4 for models differences information) Ratings : ri: AC V, 280mA, 50-60Hz, 10W

3 age: 3 of 33 Summary of testing: Testing location: Shenzhen Toby Technology Co., Ltd. 10/F., A Block, Jiada R & D Bldg., o.5 Songpingshan Road, Science & Technology ark, anshan District, Shenzhen, China Tests performed (name of test and test clause): E :2003+A1: 2011 used in conjunction with E : A11: 2009 Summary of compliance with ational Differences: Compliance with the ational requirements of CEELEC common modification. Copy of marking plate Location: sticking on the pedestal of luminaire. Led Flood Light Model o.: BR-FL-10W-01-IR Rated: V~, 280mA, 50-60Hz, 10W BREE LIGHTIG Co., LIMITED Made in China Models differences information

4 age: 4 of 33 Model Rated Voltage/ Frequency ower BR-FL-10W-01-IR BR-FL-10W BR-FL-20W BR-FL-30W BR-FL-50W BR-FL-70W BR-FL-100W BR-FL-120W BR-FL-140W BR-FL-20W-01-IR BR-FL-30W-01-IR BR-FL-50W-01-IR BR-FL-10W-01-RGB BR-FL-20W-01-RGB BR-FL-30W-01-RGB AC V Hz 10W 10W 20W 30W 50W 70W 100W 120 W 140 W 20 W 30 W 50 W 10 W 20 W 30 W BR-FL-60W-01-RGB 60 W Unless otherwise specified, the model BR-FL-10W-01-IR was chosen as representative model to perform all tests.

5 age: 5 of 33 Test item particulars... : Equipment mobility. : Fixed Class of equipment... : Class I Degree of protection.....: I23 Mass of the equipment....: Appr. 0.75kg Supply construction.... : Directly connect to supply mains ossible test case verdicts: - test case does not apply to the test object: /A - test object does meet the requirement... : (ass) - test object does not meet the requirement: F (Fail) Testing... : Date of receipt of test item... : Feb. 17, 2013 Date (s) of performance of tests... : Feb. 18, 2013 to Feb. 22, 2013 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. (See Enclosure #) refers to additional information appended to the report. (See appended table) refers to a table appended to the report. Throughout this report a comma is used as the decimal separator. Clause numbers between brackets refer to clause in E General product information: LED flood light, consists of two parts, one is lamp, the other is ballast, for outdoor use only.

6 age: 6 of (0) GEERAL TEST REQUIREMETS 3.2 (0.1) Information for luminaire design considered Standard Yes o 3.2 (0.3) More sections applicable... : Yes o 3.4 (2) CLASSIFICATIO 3.4 (2.2) Type of protection (Class 0 excluded)... : Fulfill requirements of Class I 3.4 (2.3) Degree of protection (Requirement: Ordinary). : 3.4 (2.4) Luminaire suitable for direct mounting on normally flammable surfaces... : Luminaire not suitable for direct mounting on normally flammable surfaces... : Yes o Yes o 3.4 (2.5) Luminaire for normal use... : Yes o Luminaire for rough service... : Yes o 3.4 (-) Modes of installation of road or street lighting - on a pipe (bracket) or like Yes o - on a mast arm Yes o - on a post top Yes o - on span or suspension wires Yes o - on a wall Yes o 3.5 (3) MARKIG 3.5 (3.2) Mandatory markings See marking plate osition of the marking See marking plate Format of symbols/text 3.5 (3.3) Additional information Language of instructions English 3.5 (3.3.1) Combination luminaires 3.5 (3.3.2) ominal frequency in Hz 50/60Hz 3.5 (3.3.3) Operating temperature 3.5 (3.3.4) Symbol or warning notice 3.5 (3.3.5) Wiring diagram 3.5 (3.3.6) Special conditions 3.5 (3.3.7) Metal halide lamp luminaire warning

7 age: 7 of (3.3.8) Limitation for semi-luminaires 3.5 (3.3.9) ower factor and supply current 280mA 3.5 (3.3.10) Suitability for use indoors 3.5 (3.3.11) Luminaires with remote control 3.5 (3.3.12) Clip-mounted luminaire warning 3.5 (3.3.13) Specifications of protective shields 3.5 (3.3.14) Symbol for nature of supply 3.5 (3.3.15) Rated current of socket outlet 3.5 (3.3.16) Rough service luminaire 3.5 (3.3.17) Mounting instruction for type Y, type Z and some type X attachments Type Y 3.5 (3.3.18) on-ordinary luminaires with VC cable 3.5 (3.3.19) rotective conductor current in instruction if applicable 3.5 (3.3.20) rovided with information if not intended to be mounted within arms reach 3.5 (3.4) Test with water Test with hexane Legible after test Label attached 3.5 (-) Additional information in instruction leaflet Design attitude Weight Overall dimensions Maximum projected area if applicable Cross-sectional area of wires if applicable Suitability for indoors use Dimensions of the compartment Torque setting to be applied to bolts or screws 3.6 (4) COSTRUCTIO 3.6 (4.2) Components replaceable without difficulty 3.6 (4.3) Wireways smooth and free from sharp edges 3.6 (4.4) Lampholders 3.6 (4.4.1) Integral lampholder

8 age: 8 of (4.4.2) Wiring connection 3.6 (4.4.3) Lampholder for end-to-end mounting 3.6 (4.4.4) ositioning - pressure test ()... : After test the lampholder comply with relevant standard sheets and show no damage After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation - bending test ()... : After test the lampholder have not moved from its position and show no permanent deformation 3.6 (4.4.5) eak pulse voltage 3.6 (4.4.6) Centre contact 3.6 (4.4.7) arts in rough service luminaires resistant to tracking 3.6 (4.4.8) Lamp connectors 3.6 (4.4.9) Caps and bases correctly used 3.6 (4.5) Starter holders Starter holder in luminaires other than class II Starter holder class II construction 3.6 (4.6) Terminal blocks Tails Unsecured blocks 3.6 (4.7) Terminals and supply connections 3.6 (4.7.1) Contact to metal parts 3.6 (4.7.2) Test 8 mm live conductor Test 8 mm earth conductor 3.6 (4.7.3) Terminals for supply conductors 3.6 ( ) Welded connections: - stranded or solid conductor - spot welding - welding between wires - Type Z attachment - mechanical test according to electrical test according to 15.9

9 age: 9 of 33 - heat test according to and (4.7.4) Terminals other than supply connection 3.6 (4.7.5) Heat-resistant wiring/sleeves 3.6 (4.7.6) Multi-pole plug - test at (4.8) Switches: - adequate rating - adequate fixing - polarized supply - compliance with for electronic switches 3.6 (4.9) Insulating lining and sleeves 3.6 (4.9.1) Retainement Method of fixing... : 3.6 (4.9.2) Insulated linings and sleeves Resistant to a temperature > 20 C to the wire temperature or a) & c) Insulation resistance and electric strength b) Ageing test. Temperature ( C)... : 3.6 (4.10) Insulation of Class II luminaires 3.6 (4.10.1) o contact, mounting surface accessible metal parts wiring of basic insulation Safe installation fixed luminaires Capacitors and switches Interference suppression capacitors according to IEC (4.10.2) Assembly gaps: - not coincidental - no straight access with test probe 3.6 (4.10.3) Retainment of insulation: - fixed - unable to be replaced; luminaire inoperative - sleeves retained in position - lining in lampholder 3.6 (4.11) Electrical connections 3.6 (4.11.1) Contact pressure

10 age: 10 of (4.11.2) Screws: - self-tapping screws 0.5.m for lamp cap and terminal block, 1..m for lampholder, - thread-cutting screws 3.6 (4.11.3) Screw locking: - spring washer - rivets 3.6 (4.11.4) Material of current-carrying parts 3.6 (4.11.5) o contact to wood or mounting surface 3.6 (4.11.6) Electro-mechanical contact systems 3.6 (4.12) Mechanical connections and glands 3.6 (4.12.1) Screws not made of soft metal Screws of insulating material Torque test: torque (m); part... : Screw diameter for enclosure: 3.9mm Test torque:1.2m Torque test: torque (m); part... : Torque test: torque (m); part... : 3.6 (4.12.2) Screws with diameter < 3 mm screwed into metal 3.6 (4.12.4) Locked connections: - fixed arms; torque (m)... : - lampholder; torque (m)... : - push-button switches; torque 0,8 m... : 3.6 (4.12.5) Screwed glands; force (m)... : 3.6 (4.13) Mechanical strength 3.6 (4.13.1) Impact tests: - fragile parts; energy (m)... :.0.5.m for transparent cover - other parts; energy (m)... : 0.7.m for pedestal 1) live parts 2) linings 3) protection 4) covers 3.6 (4.13.3) Straight test finger 3.6 (4.13.4) Rough service luminaires

11 age: 11 of 33 - I54 or higher a) fixed b) hand-held c) delivered with a stand d) for temporary installations and suitable for mounting on a stand 3.6 (4.13.6) Tumbling barrel 3.6 (4.14) Suspensions and adjusting devices 3.6 (4.14.1) Mechanical load: A) four times the weight B) torque 2,5 m C) bracket arm; bending moment (m)... : D) load track-mounted luminaires E) clip-mounted luminaires, glass-shelve. Thickness (mm)... : Metal rod. diameter (mm)... : Fixed luminaire or independent control gear without fixing devices 3.6 (4.14.2) Load to flexible cables Mass (kg)... : Stress in conductors (/mm²)... : Mass (kg) of semi-luminaire... : Bending moment (m) of semi-luminaire... : 3.6 (4.14.3) Adjusting devices: - flexing test; number of cycles... : - strands broken - electric strength test afterwards 3.6 (4.14.4) Telescopic tubes: cords not fixed to tube; no strain on conductors 3.6 (4.14.5) Guide pulleys 3.6 (4.14.6) Strain on socket-outlets 3.6 (4.15) Flammable materials: - glow-wire test 650 C - spacing 30 mm - screen withstanding test of screen dimensions - no fiercely burning material

12 age: 12 of 33 - thermal protection - electronic circuits exempted 3.6 (4.15.2) Luminaires made of thermoplastic material with lamp control gear a) construction b) temperature sensing control c) surface temperature 3.6 (4.16) Luminaires for mounting on normally flammable surfaces o lamp control gear (compliance with Section 12) 3.6 (4.16.1) Lamp control gear spacing: - spacing 35 mm - spacing 10 mm 3.6 (4.16.2) Thermal protection: - in lamp control gear - external - fixed position - temperature marked lamp control gear 3.6 (4.16.3) Design to satisfy the test of 12.6 (see 12.6) 3.6 (4.17) Drain holes Clearance at least 5 mm 3.6 (4.18) Resistance to corrosion: 3.6 (4.18.1) - rust-resistance 3.6 (4.18.2) - season cracking in copper 3.6 (4.18.3) - corrosion of aluminium 3.6 (4.19) Ignitors compatible with ballast 3.6 (4.20) Rough service vibration 3.6 (4.21) rotective shield: 3.6 (4.21.1) Shield fitted Shield of glass if tungsten halogen lamps 3.6 (4.21.2) articles from a shattering lamp not impair safety 3.6 (4.21.3) o direct path 3.6 (4.21.4) Impact test on shield Glow-wire test on lamp compartment 3.6 (4.22) Attachments to lamps 3.6 (4.23) Semi-luminaires comply Class II

13 age: 13 of (4.24) UV radiation for tungsten halogen lamps and metal halide lamps (Annex ) 3.6 (4.25) o sharp point or edges 3.6 (4.26) Short-circuit protection: 3.6 (4.26.1) Uninsulated accessible SELV parts 3.6 (4.26.2) Short-circuit test 3.6 (4.26.3) Test chain according to Figure (-) At least I X3 or X5 respectively Column-integrated luminaires: - parts below 2,5 m - parts above 2,5 m (-) Suspension on span wires (-) Means for attaching the luminaire or external parts to its support appropriate to the weight (-) Static load test - drag coefficient... : - loaded area (m²)... : - used load ()... : - measured deformation (cm/m)... : - no rotation (-) Adjustable lampholders (-) Glass cover: - means of protection... : - number of particles... : (-) Connection compartment of column-integrated luminaire - provides adequate space - means for attachment (-) Compliance with... : (-) Doors of column-integrated luminaires: - corrosion resistance - opening only possible for an authorized person - impact test (-) Column-integrated luminaire: - dimension of the entry slot (mm)... : - cable path from the slot to the connection compartment (mm)... :

14 age: 14 of 33 - cable path free from obstruction that might cause abrasion of the cable 3.7 (11) CREEAGE DISTACES AD CLEARACES Working voltage (V)... : V~, 50/60Hz, Voltage form Sinusoidal on-sinusoidal TI < 600 > 600 Impulse withstand category (ormal category II) (Category III Annex U) Category II Category III Rated pulse voltage (kv)... : -- (1) Current-carrying parts of different polarity: cr (mm); cl (mm)... : L and : Cr=3.2mm (limit 2.5mm); Cl=2.8mm (limit 1.5mm); (2) Current-carrying parts and accessible parts: cr (mm); cl (mm)... : (3) arts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm)... : (4) Outer surface of cable where it is clamped and metal parts: cr (mm); cl (mm)... : L and to enclosure (TI<600): Cr=2.86mm (2.5mm); Cl=2.64mm (1.5mm;) (5) ot used (6) Current-carrying parts and supporting surface: cr (mm); cl (mm)... : 3.8 (7) ROVISIO FOR EARTHIG 3.8 ( ) Accessible metal parts Metal parts in contact with supporting surface Resistance < 0,5 Ω 0.15Ω 3.8 ( ) Self-tapping screws used Thread-forming screws Thread-forming screw used in a grove Earth makes contact first Earth continuity in joints etc.

15 age: 15 of (7.2.4) Locking of clamping means Compliance with Terminal blocks with integrated screwless earthing contacts tested according Annex V 3.8 (7.2.5) Earth terminal integral part of connector socket 3.8 (7.2.6) Earth terminal adjacent to mains terminals 3.8 (7.2.7) Electrolytic corrosion of the earth terminal 3.8 (7.2.8) Material of earth terminal Contact surface bare metal 3.8 (7.2.10) Class II luminaire for looping-in Double or reinforced insulation to functional earth 3.8 (7.2.11) Earthing core coloured green-yellow Length of earth conductor (-) Attachment prevented from rotation 3.9 (14) SCREW TERMIALS Separately approved; component list (see Annex 1) art of the luminaire (see Annex 3) 3.9 (15) SCREWLESS TERMIALS AD ELECTRICAL COECTIOS Separately approved; component list (see Annex 1) art of the luminaire (see Annex 4) 3.10 (5) EXTERAL AD ITERAL WIRIG 3.10 (5.2) Supply connection and external wiring 3.10 (5.2.1) Means of connection... : 3.10 (5.2.2) Type of cable... : ominal cross-sectional area (mm²)... : Cables equal to IEC or IEC (5.2.3) Type of attachment, X, Y or Z Type Y 3.10 (5.2.5) Type Z not connected to screws 3.10 (5.2.6) Cable entries: - suitable for introduction - adequate degree of protection

16 age: 16 of (5.2.7) Cable entries through rigid material have rounded edges 3.10 (5.2.8) Insulating bushings: - suitably fixed - material in bushings - material not likely to deteriorate - tubes or guards made of insulating material 3.10 (5.2.9) Locking of screwed bushings 3.10 (5.2.10) Cord anchorage: 3.10 ( ) 3.10 ( ) 3.10 ( ) - covering protected from abrasion - clear how to be effective - no mechanical or thermal stress - no tying of cables into knots etc. - insulating material or lining Cord anchorage for type X attachment: a) at least one part fixed b) types of cable c) no damaging of the cable d) whole cable can be mounted e) no touching of clamping screws f) metal screw not directly on cable g) replacement without special tool Glands not used as anchorage Labyrinth type anchorages Adequate cord anchorage for type Y and type Z attachment Tests: type Y - impossible to push cable; unsafe - pull test: 25 times; pull ()... : 60 - torque test: torque (m)... : 0.25 m - displacement 2 mm 0.2mm - no movement of conductors p - no damage of cable or cord p 3.10 (5.2.11) External wiring passing into luminaire 3.10 (5.2.12) Looping-in terminals

17 age: 17 of (5.2.13) Wire ends not tinned Wire ends tinned: no cold flow 3.10 (5.2.14) Mains plug same protection Class III luminaire plug 3.10 (5.2.16) Appliance inlets (IEC 60320) Appliance couplers of class II type 3.10 (5.2.17) o standardized interconnecting cables properly assembled 3.10 (5.2.18) Used plug in accordance with - IEC other standard 3.10 (5.3) Internal wiring 3.10 (5.3.1) Internal wiring of suitable size and type Approved by UL 3.10 ( ) 3.10 ( ) 3.10 ( ) 3.10 ( ) 3.10 ( ) 3.10 ( ) Through wiring - not delivered/ mounting instruction - factory assembled - socket outlet loaded (A)... : - temperatures... : (see Annex 2) Green-yellow for earth only Internal wiring connected directly to fixed wiring Cross-sectional area (mm²)... : 0.75mm 2 (18AWG) Insulation thickness 0.4mm minimum Extra insulation added where necessary Internal wiring connected to fixed wiring via internal current-limiting device Adequate cross-sectional area and insulation thickness Double or reinforced insulation for class II Conductors without insulation SELV current-carrying parts Insulation thickness other than VC or rubber 3.10 (5.3.2) Sharp edges etc. o moving parts of switches etc.

18 age: 18 of 33 Joints, raising/lowering devices Telescopic tubes etc. o twisting over (5.3.3) Insulating bushings: - suitable fixed - material in bushings - material not likely to deteriorate - cables with protective sheath 3.10 (5.3.4) Joints and junctions effectively insulated 3.10 (5.3.5) Strain on internal wiring 3.10 (5.3.6) Wire carriers 3.10 (5.3.7) Wire ends not tinned Wire ends tinned: no cold flow (-) Cord anchorage if applicable - pull test: 25 times; pull ()... : - torque test: torque (m)... : 3.11 (8) ROTECTIO AGAIST ELECTRIC SHOCK 3.11 (8.2.1) Live parts not accessible with standard test finger Basic insulated parts not used on the outer surface without appropriate protection Basic insulated parts not accessible with standard test finger on portable and adjustable luminaires Basic insulated parts not accessible with Ø 50 mm probe from outside, within arms reach, on wall-mounted luminaires Lamp and starterholders in portable and adjustable luminaires comply with double or reinforced insulation requirements Basic insulation only accessible under lamp or starter replacement rotection in any position Double-ended tungsten filament lamp Insulation lacquer not reliable Double-ended high pressure discharge lamp Relevant warning according to fitted to the luminaire

19 age: 19 of (8.2.2) ortable luminaire adjusted in most unfavourable position 3.11 (8.2.3.a) Class II luminaire: - basic insulated metal parts not accessible during starter or lamp replacement - basic insulation not accessible other than during starter or lamp replacement - glass protective shields not used as supplementary insulation 3.11 (8.2.3.b) BC lampholder of metal in class I luminaires shall be earthed 3.11 (8.2.3.c) Class III luminaires with exposed SELV parts: Ordinary luminaire: - touch current... : - no-load voltage... : Other than ordinary luminaire: - nominal voltage... : 3.11 (8.2.4) ortable luminaire: - protection independent of supporting surface - terminal block completely covered 3.11 (8.2.5) Compliance with the standard test finger or relevant probe 3.11 (8.2.6) Covers reliably secured 3.11 (8.2.7) Discharging of capacitors 0,5 μf ortable plug connected luminaire with capacitor Other plug connected luminaire with capacitor Discharge device on or within capacitor Discharge device mounted separately 3.12 (12) EDURACE TEST AD THERMAL TEST 3.12 (12.3) Endurance test: - mounting-position... : As in normal use (this test was performed directly supplied by power source - test temperature ( C)... : - total duration (h)... : supply voltage: Un factor; calculated voltage (V)... : 1.06*240=254.4V

20 age: 20 of 33 - lamp used... : 3.12 (12.3.2) After endurance test: - no part unserviceable - luminaire not unsafe - no damage to track system - marking legible - no cracks, deformation etc (12.4) Thermal test (normal operation) 3.12 (12.5) Thermal test (abnormal operation) 3.12 (12.6) Thermal test (failed lamp control gear condition): 3.12 (12.6.1) Through wiring or looping-in wiring loaded by a current of (A)... : - case of abnormal conditions... : - electronic lamp control gear - measured winding temperature ( C): at 1,1 Un... : - measured mounting surface temperature ( C) at 1,1 Un... : - calculated mounting surface temperature ( C)... : - track-mounted luminaires 3.12 (12.6.2) Temperature sensing control - case of abnormal conditions... : - thermal link - manual reset cut-out - auto reset cut-out - measured mounting surface temperature ( C): - track-mounted luminaires 3.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires): 3.12 (12.7.1) Luminaire without temperature sensing control 3.12 ( ) Luminaire with fluorescent lamp 70W Test method or Annex V... : Test according to : - case of abnormal conditions - Ballast failure at supply voltage (V)... : - Components retained in place after the test

21 age: 21 of 33 - Test with standard test finger after the test Test according to Annex V: - case of abnormal conditions 3.12 ( ) - measured winding temperature ( C): at 1,1 Un... : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA - case of abnormal conditions 3.12 ( ) - measured winding temperature ( C): at 1,1 Un... : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : Luminaire with short circuit proof transformers 10 VA - case of abnormal conditions - Components retained in place after the test - Test with standard test finger after the test 3.12 (12.7.2) Luminaire with temperature sensing control - thermal link Yes o - manual reset cut-out Yes o - auto reset cut-out Yes o - case of abnormal conditions - highest measured temperature of fixing point/exposed part ( C):... : Ball-pressure test: - part tested; temperature ( C)... :

22 age: 22 of 33 - part tested; temperature ( C)... : (-) Temperature reduction if for outdoor use only (-) Tests order for luminaires with > I (9) RESISTACE TO DUST, SOLID OBJECTS AD MOISTURE 3.13 (9.2) Tests for ingress of dust, solid objects and moisture: - classification according to I... : - mounting position during test... : As in normal use - fixing screws tightened; torque (m)... : -- - tests according to clauses... : Clause electric strength test afterwards a) no deposit in dust-proof luminaire b) no talcum in dust-tight luminaire c) no trace of water on current-carrying parts or SELV parts or where it could become a hazard d) i) For luminaires without drain holes no water entry d) ii) For luminaires with drain holes no hazardous water entry e) no water in watertight luminaire f) no contact with live parts (I 2X) I23 f) no entry into enclosure (I 3X and I 4X) f) no contact with live parts (I3X and I4X) g) no trace of water on part of lamp requiring protection from splashing water h) no damage of protective shield or glass envelope 3.13 (9.3) Humidity test 48 h (-) Tests order for luminaires with > I (10) ISULATIO RESISTACE AD ELECTRIC STREGTH 3.14 (10.2.1) Insulation resistance test Cable or cord covered by metal foil or replaced by a metal rod of mm Ø... : Insulation resistance (MΩ) SELV:

23 age: 23 of 33 - between current-carrying parts of different polarity... : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : Other than SELV: >500MΩ >500MΩ >500MΩ - between live parts of different polarity... : >500MΩ - between live parts and mounting surface... : >500MΩ - between live parts and metal parts... : >500MΩ - between live parts of different polarity through action of a switch... : 3.14 (10.2.2) Electric strength test Dummy lamp Luminaires with ignitors after 24 h test Luminaires with manual ignitors Test voltage (V): SELV: - between current-carrying parts of different polarity... : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : Other than SELV: 500V 500V 500V - between live parts of different polarity... : 2* =1480V - between live parts and mounting surface... : 4* =2960V - between live parts and metal parts... : 2* =1480V - between live parts of different polarity through action of a switch... : 3.14 (10.3) Touch current (ma)... : ma 3.15 (13) RESISTACE TO HEAT, FIRE AD TRACKIG (13.2.1) Ball-pressure test: - part tested; temperature ( C)... : Bobbin of T1: 125 C - part tested; temperature ( C). - part tested; temperature ( C). CB of ballast: 125 C

24 age: 24 of 33 - part tested; temperature ( C)... : - part tested; temperature ( C). - part tested; temperature ( C)... : 3.15 (13.3.1) eedle flame test (10 s): - part tested... : Bobbin of T1: 125 C - part tested... : CB of ballast: 125 C - part tested... : L1 bobbin - part tested... : - part tested... : - part tested... : 3.15 (13.3.2) Glow-wire test (650 C): - part tested... : Insulation tape of T1 - part tested... : - part tested... : - part tested... : 3.15 (13.4.1) Tracking test: part tested... :

25 age: 25 of 33 Object/part o. AEX 1: components Manufacturer/ trademark Internal wire Various Various VW-1, 300V, 80 o C, 22/18 AWG Type/model Technical data Standard Mark(s) of conformity -- UL Supply cord Various HO5R-F 3*0.75mm2, 300/500V -- VDE Fuse (F1) Various Various F1AL, 250 VAC, E E VDE CY1 capacitor Various Various 2200Uf, 250 VAC, 100C, Y1 Transformer (T1) - rimary winding IEC : 2005 E : Class B E E Various Various olyurethane, 130 VDE UL -- UL -Triple wire Various Various UL - Bobbin Various Various henolic; V-0, 130 C, thicknes 0.4 mm minimum -- UL -Insulation tape Various Various 130 o C UL 510 UL CB of driver Various Various V-0; 130 o C -- UL Transparent cover Various Various HB, 50 C min. -- UL Input Output Voltage (V) Freq. (Hz) Current (ma) BR-FL-10W ower (W) Voltage (V) Current (A) Load o-load Load oload

26 age: 26 of 33 AEX 2: temperature measurements, thermal tests of Section 12 Type reference : BR-FL-10W-01-IR Lamp used : Lamp control gear used : Electronic driver Mounting position of luminaire : As in normal use Supply wattage (W) : 10W Supply current (A) : 280mA Calculated power factor : -- Table: measured temperatures corrected for ta = 40 C: - abnormal operating mode : -- - test 1: rated voltage...: 220V - test 2: 1,06 times rated voltage or 1,05 times rated wattage...: 240*1.06=254.4V - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage...: - test 4: 1,1 times rated voltage or 1,05 times rated wattage...: Through wiring or looping-in wiring loaded by a current of A during the test...: temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 220V test V test 3 limit test 4 limit Internal wire Surface of E-cap(C1) CB under T Winding(T1) Bobbin Ref Surface of Y-Cap Metal enclosure Transparent cover outer surface Testing ambient

27 age: 27 of 33 AEX 3: screw terminals (part of the luminaire) (14) SCREW TERMIALS (14.2) Type of terminal...: Rated current (A)...: ( ) One or more conductors ( ) Special preparation ( ) Terminal size Cross-sectional area (mm²)...: (14.3.3) Conductor space (mm)...: (14.4) Mechanical tests (14.4.1) Minimum distance (14.4.2) Cannot slip out (14.4.3) Special preparation (14.4.4) ominal diameter of thread (metric ISO thread)...: External wiring o soft metal (14.4.5) Corrosion (14.4.6) ominal diameter of thread (mm)...: Torque (m)...: (14.4.7) Between metal surfaces Lug terminal Mantle terminal ull test; pull ()...: (14.4.8) Without undue damage

28 age: 28 of 33 AEX 4: screwless terminals (part of the luminaire) (15) SCREWLESS TERMIALS (15.2) Type of terminal...: Rated current (A)...: (15.3.1) Material (15.3.2) Clamping (15.3.3) Stop (15.3.4) Unprepared conductors (15.3.5) ressure on insulating material (15.3.6) Clear connection method (15.3.7) Clamping independently (15.3.8) Fixed in position ( ) Conductor size Type of conductor (15.5.1) Terminals internal wiring ( ) ull test spring-type terminals (4, 4 samples).: ( ) ull test pin or tab terminals (4, 4 samples) : Insertion force not exceeding 50 (15.5.2) ermanent connections: pull-off test (20 ) (15.6) Electrical tests Voltage drop (mv) after 1 h (4 samples)...: Voltage drop of two inseparable joints umber of cycles...: Voltage drop (mv) after 10th alt. 25th cycle (4 samples)...: Voltage drop (mv) after 50th alt. 100th cycle (4 samples)...: After ageing, voltage drop (mv) after 10th alt. 25th cycle (4 samples)...: After ageing, voltage drop (mv) after 50th alt. 100th cycle (4 samples)...: (15.7) Terminals external wiring Terminal size and rating (15.8.1) ull test spring-type terminals or welded connections (4 samples); pull ()...:

29 age: 29 of 33 ull test pin or tab terminals (4 samples); pull ()...: (15.9) Contact resistance test Voltage drop (mv) after 1 h terminal voltage drop (mv) Voltage drop of two inseparable joints Voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)...: terminal voltage drop (mv) Voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)...: terminal voltage drop (mv) Continued ageing: voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)...: terminal voltage drop (mv) Continued ageing: voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)...: terminal voltage drop (mv)

30 age: 30 of 33 hoto 1 View of EUT EUT hotos hoto 2 View of EUT

31 age: 31 of 33 hoto 3 Internal of EUT hoto 4 CB of EUT

32 age: 32 of 33 hoto 5 CB of EUT hoto 6 View of EUT

33 age: 33 of 33 hoto 7 View of EUT ED OF REORT

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz

More information

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements Section 1: Fixed general purpose luminaires Report Number.... : 64.140.11.02922.03 Date of issue... : 2015-02-02 Total number of pages...

More information

EN : MEASUREMENT AND TEST REPORT For

EN : MEASUREMENT AND TEST REPORT For E 60598-1: 2004 MEASUREMET AD TEST REORT For LOGSTAR LIGHTIG GROU TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, China Model:LS-T8-T600S1,LS-T8-T900S1,LS-T8-T1200S1,LS-T8-T1500S1,LS-T8-M600S1,

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date

More information

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China Summary of testing: Tests performed (name of test and test clause): The submitted samples were found to comply with the requirements of: -- E 60598-2-2:2012 -- E 60598-1:2008+A11:2009 Testing location:

More information

Page 1 of 27 Report No. : HT15DR LVD Test Report

Page 1 of 27 Report No. : HT15DR LVD Test Report age 1 of 27 LVD Test Report EN60598-1&EN60598-2-1 art 1:General requirement and tests art 2: articular requirments Section One Fixed general purpose luminaires Report reference No.......: HT15DR-120321

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CGZ3150109-00114-L-F GZ test site: A101, o.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Number.... : 17041854 001 Date of

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598.

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598. Doc Id: AS/ZS60598.2.1:2014+A1 Report o: 0803BSS-61900_59821 age 1 of 49 Compliance Testing Report for Australian/ew Zealand Standard AS/ZS 60598.2.1: 2014 Inc Amendment 1 in conjunction with AS/ZS60598.1:2013

More information

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights TEST REORT EN 60598-2-21 Luminaires art 2: articular requirements Section 21: Rope Lights Report reference No.... : ED170727001S Tested by... : Coral Chen Approved by... : Kobe Mai Date of issue... : August

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REORT Luminaires art 2.1: articular requirements Fixed general purpose luminaires Accredited for compliance with ISO/IEC 17025 Report Reference No.... : S17031 Compiled by (+ signature)... : Yongchan

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :

More information

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED age 1 of 47 Report o. R011501451I SAA TEST REORT On Behalf of AOK LED LIGHT COMAY LIMITED LED Street Light Model: AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL,

More information

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting TEST REORT AS/ZS 60598.2.3:2015 Luminaires art 2.3: articular requirements Luminaires for road and street lighting Report Reference o.... : RSZ170419551-03 Compiled by (+ signature)... : Andy Fu Approved

More information

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China,

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China, Shenzhen BST Technology Co., Ltd Shenzhen Merrylux Optoelectronics co., ltd TEST REORT repared For: Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan,

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No....: TGM-VA EE32453 SFT Date of issue...

More information

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires TEST REORT Luminaires art 1: General requirements and Tests art 2: articular requirements - Section 4: ortable general purpose luminaires Report Reference o: Tested by: T1321-21-12 Urs Wyttenbach Approved

More information

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires Report Reference o....: Compiled by (+ signature)...: Approved by (+ signature)... : TEST REORT AS/ZS 60598.2.1 Luminaires art 2: articular requirements: Fixed general purpose luminaires RSZ160822550-03

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires age 1 of 40 TEST REORT IEC 60598-2-2 Luminaires art 2: articular requirements Section 2: Recessed luminaires Report Number.... : 7040216100405-00 Date of issue... : 2016-11-18 Total number of pages...

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires Test Report issued under the responsibility of: TEST REORT E 60598-2-2: 1996 LUMIAIRES --- SAFETY--- ART 2-2: articular requirements- Recessed luminaires Report reference o...: GTSS12080044101 Compiled

More information

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires TEST REORT EN 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No...: 3007562.50-QUA/LI Date of issue...: 2011-03-28 Total number of pages...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Test Report issued under the responsibility of: Studio Oleandri - Milano TEST REPORT IEC 60598-2-1 Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Report Number...

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050805SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan Road,

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050811SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For : SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests Test Report issued under the responsibility of: Report Reference o...: age 1 of 11 TEST REORT IEC 60968 and/or E 60968 Luminaires art 1: General Requirements And Tests GTSS12060031301 Date of issue...:

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd age 1 of 55 Report o. R011607605S-1 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co.,Ltd LED Flood Light Model: QH-FLXH01-50W, QH-FLXH02-100W, QH-FLXH03-150W, QH-FLXH04-200W,

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT IEC LED modules for general lighting Safety specifications Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant

More information

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd.

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd. TEST REORT Reference o.... : WTF15F0730677S Applicant... : Foshan anhai Vorld Lighting Co., Ltd. Address... : 18th west Taoyuan Road, Shishan Town, anhai District, Foshan City, Guangdong rovince Manufacturer...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 1540-44-I Date of issue... : 2016-09-01

More information

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED LVD REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED LVD REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Shenzhen BST Technology Co., Ltd Report o.: BSTDG13050806SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED LVD REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark :

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark : CERTIFICATE of Conformity Reference o. : LCS1702161029S 001 Applicant : LOKOLED Address : Kitmanstraat 14 1812 M Alkmaar The etherlands Trademark : /A roduct : LED Downlight Model(s) : (see attached) arameters

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

Remark: Whether parts of tests for the product have been subcontracted to other labs:

Remark: Whether parts of tests for the product have been subcontracted to other labs: Reference o.: WTS16S1166817S age 2 of 60 Test item description...: Trademark...: Model and/or type reference...: AU-BD350VA Rating(s)... : 220-240V~, 50Hz, Max. 350VA, Min 10VA Remark: Whether parts of

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 6011995.50 Date of issue... :

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

TEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD

TEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD Report o.: BST14090471Y-1SR-2 SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD TEST REORT repared For : SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD 4F,Building A,YouXinDa Industrial Area, GenYu Road,TianLiao

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REPORT Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Report Reference No...: HZ10120073-001 ate of issue...:

More information

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment):

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment): age 3 of 90 Report No.: 17052930 001 List of Attachments (including a total number of pages in each attachment): Attachment 1: 12 pages of photos. Summary of testing: Tests performed (name of test and

More information

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances - age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

For. Shanghai Moons Automation Control Co., Ltd.

For. Shanghai Moons Automation Control Co., Ltd. Shenzhen BCTC Technology Co., Ltd. Report o.: BCTC-13080904S ALICATIO FOR LVD For Shanghai Moons Automation Control Co., Ltd. roduct ame: LED drivers Trademark: Model : repared For : MU096A024A, MU096A175AQD

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

Test report: 13/ Date January 20 th,2014 Page 1 of 52

Test report: 13/ Date January 20 th,2014 Page 1 of 52 LGAI LGAI Technological Center, S.A. Campus de la UAB Apartado de Correos 18 E - 08193 Bellaterra (Barcelona) T +34 93 567 20 00 F +34 93 520 20 01 www.appluslaboratories.com TEST REORT Test report: 13/31705080

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

TEST REPORT EN Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT EN Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules TEST REORT E 61347-2-13 Lamp controlgear art 2-13: articular requirements for d.c. or a.c. supplied electronic controlgear for LED modules Report umber.... : TCDQ02170721805S-LD01 Date(s) of performance

More information

Test Report issued under the responsibility of: Report Number...:

Test Report issued under the responsibility of: Report Number...: Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016

More information

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007 Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches Test Report issued under the responsibility of: TEST REPORT Switches for appliances Part 2-1: Particular requirements for cord switches Report Reference No.... : SH11080876-001 Date of issue... : 2012-02-23

More information

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82 age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang

More information

Page 3 of 32 Report No Summary of testing:

Page 3 of 32 Report No Summary of testing: age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:

More information

Test Report No EEC12-02/MLM dated 29 MAR 2012

Test Report No EEC12-02/MLM dated 29 MAR 2012 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD SB te Ltd. In addition, this report is

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of TEST REORT IEC 60884-1 lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 2228900-1520-0001/175202

More information