1 E : 2004 MEASUREMET AD TEST REORT For LOGSTAR LIGHTIG GROU TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, China Model:LS-T8-T600S1,LS-T8-T900S1,LS-T8-T1200S1,LS-T8-T1500S1,LS-T8-M600S1, LS-T8-M900S1, LS-T8-M1200S1, LS-T8-M1500S1 Aug. 09, 2009 MTI RS ote: This test report is limited to the above client company and the product model only. It may not be duplicated without prior written consent of MTI Technology Laboratory Ltd.

2 TEST REORT E : 2004 Luminaires --- Safety--- art 1: Genaral Requirements and tests Report reference o...: MTI RS Tested by (printed name and signature)...: Jack Shi Approved by (printed name and signature)...: Hebe Lee Date of issue...: July 02, 2009 Testing Laboratory ame...: MTI Technology Laboratory Ltd. Address...: 10F, Yinxing Business Hotel, Xixiang Road, Bao'an District, Shenzhen,.R.China. Testing location...: Same as above Applicant s name:...: LOGSTAR LIGHTIG GROU Address...: TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, Test specification Standard...: E :2004 +A1: 2006 Test procedure...: CE-LVD Scheme rocedure deviation...:.a. on-standard test method...:.a. Test Report Form o...: IEC E TRF originator...: MTI

3 Test item description...: LED Fluorescent Tube Trademark...: Manufacturer...: LOGSTAR LIGHTIG GROU Address...: TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, Model and/or type reference...: LS-T8-T1200S1 Rating(s)...: V~, 50/60Hz, 21W class II Test case verdicts: Test case does not apply to the test object. : (ot Applicable) Test object does meet the requirement...: (ass) Test object does not meet the requirement...: F(ail) Testing Date of receipt of test item.....: Jun.23, 2009 Date(s) of performance of test.....: Jun.23, 2009 to Jun.29, 2009 General remarks This report shall not be reproduced except in full without the written approval of the testing laboratory. The test results presented in this report relate only to the item tested. (see remark #)" refers to a remark appended to the report. "(see Annex #)" refers to an annex appended to the report. Throughout this report a point is used as the decimal separator. This report shall not be altered, increase and deleted. The results relate only to the items tested. This report shall not be published as advertisement without the approval of MTI. This report shall not be copied partly without the written approval of MTI.

4 General information: This product should be together with magnetic ballast, use with electronic ballast is prohibited, install onto the original T8 frame. Models LS-T8-T600S1, LS-T8-T900S1, LS-T8-T1500S1, LS-T8-M600S1, LS-T8-M900S1 are idendical except the model name and quantity of LED for different output power, test performed on model LS-T8-T1200S1. Copy of the marking plate: LED Fluorescent Tube Model o: LS-T8-T1200S1 Voltage: AC90V-265V 50/60Hz Rated ower: 21W Color temperature: K Work Temperature: -30 C~+50 C I50 LOGSTAR LIGHTIG GROU

5 E : General test requirements 0.1 Information for luminaire design considered Standard 0.3 More sections applicable... : -- 2 CLASSIFICATIO 2.2 Type of protection...: Semi-luminaires shall comply with all relevant requirements for class II luminaires 2.3 Degree of protection...: 2.4 Classified according to whether they 2.5 Fixed luminaire suitable for normally flammable surfaces...: Fixed luminaire suitable for non-combustible materials only...: Luminaire for normal use...: Luminaire for rough service...: o symbol 3 MARKIG 3.2 Mandatory markings osition of the marking Format of symbols/text Mark of origin See label Rated voltage(s) in volts V~ The rated maximum ambient temperature ta Symbol for class II luminaires Class II Symbol for class III luminaires I numbers I Maker's model number or type reference LS-T8-T1200S Rated wattage 21W osition of mounting Install in lamp holder

6 - Suitable for normally flammable surfaces Information concerning special lamps E : Similar shape to "cool beam" lamps Terminations mark Minimum distance from lighted objects For rough service luminaires For use with bowl mirror lamps Luminaires incorporating a glass protective shield The maximum number of interconnecting luminaires For luminaires with ignitors For use with self-shielded tungsten halogen lamps only 3.3 Additional information Language of instructions English Combination luminaires ominal frequency in Hz 50/ Operating temperature Symbol or warning notice Wiring diagram Special conditions Metal halid lamp luminaire warning Limitation for semi-luminaires supply information on limitations of use of such devices ower factor and supply current Suitability for use indoors Luminaires with remote control Clip-mounted luminaire warning Specifications of protective shields Symbol for nature of supply ~ Rated current of socket outlet o such outlet Rough service luminaire

7 - connection to IX4 rated socket outlets - correct mounting taking into account the temporary installation E : correct fixing to a stand - maximum height of stand - number of the legs - minimum length of the legs Mounting instruction for type Y, type Z and some type X attachments The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire shall be destroyed 3.4 Test of marking Type Z attachments See mounting instruction - Test with water 15s - Test with hexane 15s - Legible after test - Label attached 4 COSTRUCTIO 4.2 Components replaceable without difficulty 4.3 Wireways smooth and free from sharp edges 4.4 Lampholders Integral lampholder Wiring connection Lampholder for end-to-end mounting ositioning - pressure test ()...: - bending test (m)...: 2.m eak pulse voltage Centre contact Rough service luminaires Lamp connectors 4.5 Starter holders

8 Starter holder in luminaires other than class II Starter holder class II construction 4.6 Terminal blocks E : 2004 Tails Unsecured blocks 4.7 Terminals and supply connections Contact to metal parts Location stranded wires 8 mm test live conductor Considered 8 mm test earth conductor Terminals for supply conductors Terminals other than supply connection Heat-resistant wiring/sleeves Multi-pole plug 4.8 Switches: - adequate rating - adequate fixing - polarized supply 4.9 Insulating lining and sleeves Retainment Method of fixing...: Insulated linings and sleeves a) & c) Insulation resistance and electric strength b) Ageing test. Temperature ( C)...: 4.10 Insulation of Class II luminaires o contact, mounting surface - accessible metal parts - wiring of basic insulation Safe installation fixed luminaires Capacitors Interference suppression capacitors according to IEC

9 Assembly joints: - not coincidental - no straight access - degree of protection Retainment of insulation: E : fixed - unable to be replaced; luminaire inoperative - sleeves retained in position - lining in lampholder 4.11 Electrical connections Contact pressure Screws: - spaced threaded screws - thread-cutting screws - earth continuity - at least two screws Screw locking: - spring washer - rivets Material of current-carrying parts Copper pins o contact to wood Electro-mechanical contact systems 4.12 Mechanical connections and glands Mechanical stress ot made of soft metal Screws of insulating material o metal screw used Torque test: torque (m); part...: 0.4.m for pcb screw Torque test: torque (m); part...: Torque test: torque (m); part...: Screw diameter up to 3 mm Locked connections:

10 - fixed arms; torque (m)...: - lampholder; torque (m)...: - push-button switches; torque (m)...: Screwed glands; force ()...: 4.13 Mechanical strength Impact tests: E : fragile parts; energy (m)... : 0,2 m - other parts; energy (m)... : 0,35 m 1) live parts 2) linings 3) protection 4) covers Straight test finger Rough service luminaires I ( I54) a) fixed b) hand-held c) delivered with a stand d) for temporary installations and suitable for mounting on a stand Tumbling barrel 4.14 Suspensions and adjusting devices Mechanical load: A) four times the weight B) torque 2,5 m C) bracket arm; force ()...: D) load track-mounted luminaires E) clip-mounted luminaires, glass-shelve. Thickness (mm)...: metal rod. Diameter (mm)...:

11 Load to flexible cables Mass (kg)...: Stress in conductors (/mm²)...: Semi-luminaires mass (kg)...: Semi-luminaires bending moment (m)...: Adjusting devices: - rotating test; number of cycles...: - strands broken - high voltage test E : Telescopic tubes: cords not fixed to tube; no strain on conductors Guide pulleys Strain on socket-outlets 4.15 Flammable materials: - glow-wire test 650 C - spacing 30 mm - screen withstanding test of screen dimensions - no fiercely burning material - thermal protection - electronic circuits exempted Luminaires made of thermoplastic material a) construction b) temperature sensing control c) surface temperature 4.16 Luminaires marked with "F" symbol o lamp control gear Lamp control gear spacing: - spacing 35 mm - spacing 10 mm

12 Thermal protection: - in lamp control gear - external - fixed position - temperature marked lamp control gear "F" curve measured 4.17 Drain holes Clearance at least 5 mm 4.18 Resistance to corrosion: rust-resistance season cracking in copper corrosion of aluminium E : Ignitors compatible with ballast 4.20 Rough service vibration...: 4.21 rotective shield: Shield fitted articles from a shattering lamp not impair safety o direct path Impact test on shield Glow-wire test on lamp compartment 4.22 Attachments to lamps 4.23 Semi-luminaires comply class II 4.24 UV radiation, metal halide lamps 4.25 o sharp point or edges 4.26 Short-circuit protection: Uninsulated accessible SELV parts Short-circuit test Test chain according to IEC EXTERAL AD ITERAL WIRIG 5.2 Supply connection and external wiring

13 5.2.1 Means of connection...: G8 cap Type of cable...: ominal cross-sectional area (mm²)...: Replacement of non-detachable cable and cords on-rewirable connection Cable entries: - suitable for introduction - adequate degree of protection Cable entries through rigid material have rounded edges Insulating bushings: - suitably fixed - material in bushings - tubes or guards made of insulating material E : Locking of bushings Cord anchorage: - covering protected from abrasion o power cord - clear how to be effective - no mechanical or thermal stress - no tying of cables into knots etc insulating material or lining For type X attachment, cord anchorage shall be such that: a) at least one part fixed b) types of cable c) no damaging of the cable d) whole cable can be mounted e) no touching of clamping screws f) metal screw not directly on cable g) replacement without special tool Glands not used as anchorage Labyrinth type anchorages

14 For type Y and Z attachments, cord anchorages shall be adequate Tests: - impossible to push cable; unsafe - pull test: 25 times; pull ()... : - torque test: torque (m)... : - displacement 2 mm - no movement of conductors - no damage of cable or cord External wiring passing into luminaire Looping-in terminals Wire ends not tinned Wire ends tinned: no cold flow Mains plug same protection Class III luminaire plug E : Colour code low voltage Appliance inlets (IEC 60320) Appliance couplers of class II type 5.3 Internal wiring Cross-sectional area (mm²)...: Insulation thickness Temperature resistant 0.5 mm² Sleeves suitable for hot spots Green-yellow for earth only Through wiring - cross-sectional area (mm²)...: - not delivered/ mounting instruction - factory assembled - socket outlet loaded (A)...: - temperatures...: Sharp edges etc.

15 o moving parts of switches etc. Complies with Joints, raising/lowering devices Telescopic tubes etc. o twisting over Openings Bushings not removable Bushings in sharp openings Cables with protective sheath Joints and junctions: - easily accessible - effectively insulated Strain on internal wiring Wire carriers Wire ends not tinned Wire ends tinned: no cold flow E : ROVISIO FOR EARTHIG Metal parts Accessible metal parts Metal parts and supporting surface Resistance < 0,5 Ω Two spaced threaded screws used Thread-forming screws Connector earthing first Earth continuity Locking of clamping means Compliance with Adequate locking Loosening of clamping means Connector socket

16 osition of the earth terminal Corrosion of the earth terminal Material of earth terminal Contact surface bare metal Class II luminaire for looping-in Earthing core coloured green-yellow Length of earth conductor (3.8.1) The attachment of the fixed part of the terminal shall be designed and executed so as to prevent it from being rotated when the clamping part is moved. 8 ROTECTIO AGAIST ELECTRIC SHOCK Live parts not accessible rotection in any position Insulation lacquer not reliable E : 2004 Double-ended tungsten filament lamp Double-ended high pressure discharge lamp ortable luminaire Class II luminaire: - insulation-encased, reinforced insulation - metal-encased, double insulation Double insulation - basic insulated metal parts or basic insulated live conductors only accessible during starter or lamp replacement - glass protective shields not used as supplementary insulation Class I luminaire with BC lampholder ortable luminaire: - non-detachable cable - terminal block completely covered Covers have adequate strength (see 4.13)

17 Covers reliably secured Discharging of capacitors 0,5 µf ot 0,5 µf ortable plug connected luminaire with capacitor Other plug connected luminaire with capacitor Discharge device on or within capacitor Discharge device mounted separately 9 RESISTACE TO DUST, SOLID OBJECTS AD MOISTURE 9.2 Tests for ingress of dust, solid objects and moisture: - classification according to I... : - mounting position during test... : - fixing screws tightened; torque (m)... : - tests according to clauses... : - electric strength a) no deposit in dust-proof luminaire b) no talcum in dust-tight luminaire c) no trace of water on live parts E : 2004 d) no accumulation of water in waterproof luminaire e) no water in watertight luminaire f) no contact with live parts (I 2X) f) no entry into enclosure (I 3X and I 4X) 9.3 Humidity test 48 h (3.13.1) For luminaires with an I classification greater than I20 the order of the tests specified in section 9 of shall be as specified in 3.12 of this section of IEC ISULATIO RESISTACE AD ELECTRIC STREGTH 1.14 (10.2.1) Insulation resistance test: Class of protection... : Class II Insulation resistance (MΩ): SELV:

18 - between current-carrying parts of different polarity... : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : Other than SELV: - between live parts of different polarity... : - between live parts and mounting surface : > 4 MΩ - between live parts and metal parts... : > 4 MΩ - between live parts of different polarity through action of a switch... : Electric strength test Class of protection... : Class II appliance Dummy lamp Luminaires with ignitors after 24 h test Luminaires with manual ignitors Test voltage (V): SELV: E : between current carrying parts of different polarity... : - between current carrying parts and mounting surface... : - between carrying parts and metal parts of the luminaire... : Other than SELV: o SELV circuit - between live parts of different polarity... : 2 x = between live parts and mounting surface : 4 x = between live parts and metal parts... : 2 x = between live parts of different polarity through action of a switch... : Leakage current (ma)... : < 0.5 ma 11 CREEAGE DISTACES AD CLEARACES Class of protection... : Class II

19 Working voltage (V)... : 265V Voltage form Sinusoidal TI < 600 Rated pulse voltage (kv)... : (1) Live parts of different polarity: cr (mm); cl (mm)... : (2) Live parts and accessible parts: cr (mm); cl (mm)... : Cr=Cl>8mm; Limit:Cr: 8mm Cl: 4mm Cr>Cl>9mm; Limit: 9 mm (3) arts becoming live: cr (mm); cl (mm).. : (4) Outer surface of cable: cr (mm); cl (mm): (5) Live parts of switches: cr (mm); cl (mm): (6) Live parts and supporting surface: cr (mm); cl (mm)... : Cr>Cl>9mm; Limit: 9mm 12 EDURACE TEST AD THERMAL TEST 12.3 Endurance test: - mounting-position... : In lamp holder - test temperature ( C)... : 30 E : total duration (h)... : 168h - supply voltage: Un factor; calculated voltage (V): 292V - lamp used... : T8 tubular with many LED After endurance test: - no part unserviceable - luminaire not unsafe - no damage to track system - marking legible - no cracks, deformation etc Thermal test (normal operation) (see Annex ) 12.5 Thermal test (abnormal operation) (see Annex ) 12.6 Thermal test (failed lamp control gear condition): case of abnormal conditions... : - electronic lamp control gear

20 - measured winding temperature ( C) at 1,1 Un : - measured mounting surface temperature ( C) at 1,1 Un... : - calculated mounting surface temperature ( C) : - track-mounted luminaires Temperature sensing control - thermal link - manual reset cut-out - auto reset cut-out - measured mounting surface temperature ( C)... : - track-mounted luminaires 12.7 Thermal test (failed lamp control gear in plastic luminaires): - case of abnormal conditions... : measured winding temperature ( C) at 1,1 Un : - measured temperature of fixing point/ exposed part ( C) at 1,1 Un... : - calculated temperature of fixing point/ exposed part ( C)... : E : Temperature sensing control - thermal link - manual reset cut-out - auto reset cut-out - measured temperature of fixing point/ exposed part ( C)... : 13 RESISTACE TO HEAT, FIRE AD TRACKIG Ball-pressure test: - part tested; temperature ( C)... : 125 for lamp cap - part tested; temperature ( C)... : eedle flame test (10 s): - part tested... : - part tested... :

21 Glow wire test (650 C): - part tested... : Lamp cap - part tested... : Tracking test: part tested... : 14 SCREW TERMIALS 14.1 General: o screw terminals 14.2 Type of terminal... : Rated current (A)... : One or more conductors Special preparation Terminal size Cross-sectional area (mm²)... : Conductor space (mm)... : 14.4 Mechanical tests Minimum distance Cannot slip out Special preparation E : ominal diameter of thread (metric ISO thread) : External wiring o soft metal Corrosion ominal diameter of thread (mm)... : Torque (m)... : Between metal surfaces Lug terminal Mantle terminal ull test; pull ()... : Without undue damage 15 SCREWLESS TERMIALS AD ELECTRICAL COECTIOS

22 15.1 General: 15.2 Type of terminal... : on-premanent conductors Rated current (A)... : Material Copper pins Clamping Stop Unprepared conductors ressure on insulating material Clear connection method Clamping independently Fixed in position Conductor size Type of conductor Terminals internal wiring ull test spring-type terminals (4, 4 samples) ull test pin or tab terminals (4, 4 samples) Insertion force not exceeding ermanent connections: pull-off test (20 ) 15.6 Electrical tests E : 2004 Voltage drop (mv) after 1 h (4 samples)... : <15mV Voltage drop of two inseparable joints umber of cycles... : 25th cycle Voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : Voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : After ageing, voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : After ageing, voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : <7.5mV 15.7 Terminals external wiring Terminal size and rating

23 ull test spring-type terminals (4 samples); pull () ull test pin or tab terminals (4 samples); pull () 15.9 Contact resistance test ZB AEX ZB, SECIAL ATIOAL CODITIOS 2.2 Class 0 not accepted 3.3 DK: power supply cord with label IT: warning label on Class 0 luminaire DK: socket-outlets FR: socket-outlets DK, FI, SE, GB: type of plug ZC AEX ZC, ATIOAL DEVIATIOS 13.3 DK: eedle flame test or glow-wire test 750 for luminaires in access routes 13.3 GB: Requirements according to United Kingdom Building Regulation FR: Glow-wire test 850 alt. 750 for luminaires in premises open to public and workers

24 Type reference...: Lamp used...: Lamp control gear used...: Mounting position of luminaire...: Supply wattage (W)...: Supply current (A)...: Table: measured temperatures corrected for ta = 25 C: LS-T8-T1200S1 21W tubular.a. Install in G8 lamp holders 21W 0.079A - abnormal operating mode...: test 2 - test 1: rated voltage...: - test 2: 1,06 times rated voltage or 1,05 times rated wattage...: - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage...: - test 4: 1,1 times rated voltage or 1,05 times rated wattage...: Through wiring or looping-in wiring loaded by a current of A during the test...:.a. 1,06 X 265V = 281V.A..A..A.

25 o LIST OF CRITICAL COMOETS Component/O bject 1 Internal wire Manufacturer Dongguan Wenchang Electronic Co Ltd Type/ Model 1672 Ratings / Technical Data 22AWG 105 VW-1 Complies with the following standard UL,CSA Marks of conformity granted UL E CB Yat Sing rinted Wiring Boards Fty Ltd CEM-1 94V-0, mm UL UL certified -Alternation Various Various 94 V UL UL certified 3 Fuse-link Sunny East Enterprise Co Ltd DI 2A 250VAC UL E VDE Inductor(L1) T E Tested with appliance 5 Insulation lining Methode Electronics (Shanghai) Co Ltd CY60(b)(c) V thickness: 0.25 min UL 94 UL E X2 capacitor Changzhou Defu Electrical Co.,Ltd MX /MK 0.22uF 250V 85 E TUV UL 7 Magnet wire of T1 Shantou Shenggang Electrical Industrial Co., Ltd olyuretha ne 130, UEW UL UL E202352

26 (LED Circuit Diagram)

27 Attachment A EUT s hotos EUT- Front Overview EUT- Back overiew

28 EUT- LED Beads CB-Top View of LED driver

29 CB-Bottom View of LED driver * * * THE ED * * *

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz

More information

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct

More information

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT) Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB13035196 Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CGZ3150109-00114-L-F GZ test site: A101, o.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements Section 1: Fixed general purpose luminaires Report Number.... : 64.140.11.02922.03 Date of issue... : 2015-02-02 Total number of pages...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total

More information

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China Summary of testing: Tests performed (name of test and test clause): The submitted samples were found to comply with the requirements of: -- E 60598-2-2:2012 -- E 60598-1:2008+A11:2009 Testing location:

More information

Page 1 of 27 Report No. : HT15DR LVD Test Report

Page 1 of 27 Report No. : HT15DR LVD Test Report age 1 of 27 LVD Test Report EN60598-1&EN60598-2-1 art 1:General requirement and tests art 2: articular requirments Section One Fixed general purpose luminaires Report reference No.......: HT15DR-120321

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date

More information

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China,

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China, Shenzhen BST Technology Co., Ltd Shenzhen Merrylux Optoelectronics co., ltd TEST REORT repared For: Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan,

More information

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598.

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598. Doc Id: AS/ZS60598.2.1:2014+A1 Report o: 0803BSS-61900_59821 age 1 of 49 Compliance Testing Report for Australian/ew Zealand Standard AS/ZS 60598.2.1: 2014 Inc Amendment 1 in conjunction with AS/ZS60598.1:2013

More information

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires TEST REORT Luminaires art 1: General requirements and Tests art 2: articular requirements - Section 4: ortable general purpose luminaires Report Reference o: Tested by: T1321-21-12 Urs Wyttenbach Approved

More information

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED age 1 of 47 Report o. R011501451I SAA TEST REORT On Behalf of AOK LED LIGHT COMAY LIMITED LED Street Light Model: AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL,

More information

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights TEST REORT EN 60598-2-21 Luminaires art 2: articular requirements Section 21: Rope Lights Report reference No.... : ED170727001S Tested by... : Coral Chen Approved by... : Kobe Mai Date of issue... : August

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REORT Luminaires art 2.1: articular requirements Fixed general purpose luminaires Accredited for compliance with ISO/IEC 17025 Report Reference No.... : S17031 Compiled by (+ signature)... : Yongchan

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Number.... : 17041854 001 Date of

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :

More information

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires Test Report issued under the responsibility of: TEST REORT E 60598-2-2: 1996 LUMIAIRES --- SAFETY--- ART 2-2: articular requirements- Recessed luminaires Report reference o...: GTSS12080044101 Compiled

More information

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting TEST REORT AS/ZS 60598.2.3:2015 Luminaires art 2.3: articular requirements Luminaires for road and street lighting Report Reference o.... : RSZ170419551-03 Compiled by (+ signature)... : Andy Fu Approved

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050805SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan Road,

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires Report Reference o....: Compiled by (+ signature)...: Approved by (+ signature)... : TEST REORT AS/ZS 60598.2.1 Luminaires art 2: articular requirements: Fixed general purpose luminaires RSZ160822550-03

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050811SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For : SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires age 1 of 40 TEST REORT IEC 60598-2-2 Luminaires art 2: articular requirements Section 2: Recessed luminaires Report Number.... : 7040216100405-00 Date of issue... : 2016-11-18 Total number of pages...

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No....: TGM-VA EE32453 SFT Date of issue...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Test Report issued under the responsibility of: Studio Oleandri - Milano TEST REPORT IEC 60598-2-1 Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Report Number...

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires TEST REORT EN 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No...: 3007562.50-QUA/LI Date of issue...: 2011-03-28 Total number of pages...

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED LVD REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED LVD REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Shenzhen BST Technology Co., Ltd Report o.: BSTDG13050806SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED LVD REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd age 1 of 55 Report o. R011607605S-1 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co.,Ltd LED Flood Light Model: QH-FLXH01-50W, QH-FLXH02-100W, QH-FLXH03-150W, QH-FLXH04-200W,

More information

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd.

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd. TEST REORT Reference o.... : WTF15F0730677S Applicant... : Foshan anhai Vorld Lighting Co., Ltd. Address... : 18th west Taoyuan Road, Shishan Town, anhai District, Foshan City, Guangdong rovince Manufacturer...

More information

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements

More information

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark :

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark : CERTIFICATE of Conformity Reference o. : LCS1702161029S 001 Applicant : LOKOLED Address : Kitmanstraat 14 1812 M Alkmaar The etherlands Trademark : /A roduct : LED Downlight Model(s) : (see attached) arameters

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment):

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment): age 3 of 90 Report No.: 17052930 001 List of Attachments (including a total number of pages in each attachment): Attachment 1: 12 pages of photos. Summary of testing: Tests performed (name of test and

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

TEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD

TEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD Report o.: BST14090471Y-1SR-2 SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD TEST REORT repared For : SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD 4F,Building A,YouXinDa Industrial Area, GenYu Road,TianLiao

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests Test Report issued under the responsibility of: Report Reference o...: age 1 of 11 TEST REORT IEC 60968 and/or E 60968 Luminaires art 1: General Requirements And Tests GTSS12060031301 Date of issue...:

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

Remark: Whether parts of tests for the product have been subcontracted to other labs:

Remark: Whether parts of tests for the product have been subcontracted to other labs: Reference o.: WTS16S1166817S age 2 of 60 Test item description...: Trademark...: Model and/or type reference...: AU-BD350VA Rating(s)... : 220-240V~, 50Hz, Max. 350VA, Min 10VA Remark: Whether parts of

More information

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances - age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 1540-44-I Date of issue... : 2016-09-01

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REPORT Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Report Reference No...: HZ10120073-001 ate of issue...:

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT IEC LED modules for general lighting Safety specifications Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,

More information

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 6011995.50 Date of issue... :

More information

TEST REPORT EN Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT EN Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules TEST REORT E 61347-2-13 Lamp controlgear art 2-13: articular requirements for d.c. or a.c. supplied electronic controlgear for LED modules Report umber.... : TCDQ02170721805S-LD01 Date(s) of performance

More information

For. Shanghai Moons Automation Control Co., Ltd.

For. Shanghai Moons Automation Control Co., Ltd. Shenzhen BCTC Technology Co., Ltd. Report o.: BCTC-13080904S ALICATIO FOR LVD For Shanghai Moons Automation Control Co., Ltd. roduct ame: LED drivers Trademark: Model : repared For : MU096A024A, MU096A175AQD

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has

More information

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82 age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

Test report: 13/ Date January 20 th,2014 Page 1 of 52

Test report: 13/ Date January 20 th,2014 Page 1 of 52 LGAI LGAI Technological Center, S.A. Campus de la UAB Apartado de Correos 18 E - 08193 Bellaterra (Barcelona) T +34 93 567 20 00 F +34 93 520 20 01 www.appluslaboratories.com TEST REORT Test report: 13/31705080

More information

Page 3 of 32 Report No Summary of testing:

Page 3 of 32 Report No Summary of testing: age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.

More information

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007 Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches Test Report issued under the responsibility of: TEST REPORT Switches for appliances Part 2-1: Particular requirements for cord switches Report Reference No.... : SH11080876-001 Date of issue... : 2012-02-23

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

PIL0478 ISSUE 01/ 07/16

PIL0478 ISSUE 01/ 07/16 ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 70.410.14.127.01-01 Date of issue... : 2014-07-03 Total number of pages... 61

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of TEST REORT IEC 60884-1 lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 2228900-1520-0001/175202

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

LVD TEST REPORT. On Behalf of ZHANGZHOU WEIHUA ELECTRONIC CO., LTD. DIGITAL MULTIMETER. Models: DT9201A,DT9205A,DT9208A

LVD TEST REPORT. On Behalf of ZHANGZHOU WEIHUA ELECTRONIC CO., LTD. DIGITAL MULTIMETER. Models: DT9201A,DT9205A,DT9208A Reference o.: ET10113218-LVD LVD TEST REORT On Behalf of ZHAGZHOU WEIHUA ELECTROIC CO., LTD. DIGITAL MULTIMETER Models: DT9201A,DT9205A,DT9208A repared for : ZHAGZHOU WEIHUA ELECTROIC CO., LTD. O.3 JIMA

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of XI AN BEICHENG ELECTRONICS CO., LTD. Digital Multimeter. Model no.: VICTOR 81B, VICTOR 81D

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of XI AN BEICHENG ELECTRONICS CO., LTD. Digital Multimeter. Model no.: VICTOR 81B, VICTOR 81D ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of XI A BEICHEG ELECTROICS CO., LTD Digital Multimeter Model no.: VICTOR 81B, VICTOR 81D repared for : Address: XI A BEICHEG ELECTROICS CO., LTD JIGYUA 7 ROAD,

More information

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

Intertek Testing Service Taiwan Ltd. 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan as above Recom Development & Trading GmbH & Co KG

Intertek Testing Service Taiwan Ltd. 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan as above Recom Development & Trading GmbH & Co KG age 1 of 38 Report No.ETS-060067 TEST REORT IEC 60601-1 / EN 60601-1 Medical electrical equipment art 1: General requirements for safety Report reference No.... : ETS-060067 Testled by (+ signature)...

More information