APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of XI AN BEICHENG ELECTRONICS CO., LTD. Digital Multimeter. Model no.: VICTOR 81B, VICTOR 81D

Size: px
Start display at page:

Download "APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of XI AN BEICHENG ELECTRONICS CO., LTD. Digital Multimeter. Model no.: VICTOR 81B, VICTOR 81D"

Transcription

1 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of XI A BEICHEG ELECTROICS CO., LTD Digital Multimeter Model no.: VICTOR 81B, VICTOR 81D repared for : Address: XI A BEICHEG ELECTROICS CO., LTD JIGYUA 7 ROAD, JIGHE IDUSTRIAL ARK, ORTH DISTRICT, XI A, CHIA repared By : Address: roduct Technology Service(ingbo) Co., Ltd. 3/F., Building 1, Hengyu Industrial ark, Fengjia, Shiqi Street,Yinzhou District, ingbo, Zhejiang, China Date of Test: March 27 march 30, 2017 Date of Report: April 11, 2017 Report umber: S Version umber: REV0

2 TEST REORT IEC / E Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General requirements Report Reference o... : Originator (name + signature)...: Verifier (name + signature)...: Authorize (name + signature)... : S Danyan Wang Meng Wei Shizong ie Date of issue...: April 11, 2017 Testing Laboratory...: Address... : roduct Technology Service(ingbo) Co., Ltd. 3/F., Building 1, Hengyu Industrial ark, Fengjia, Shiqi Street,Yinzhou District, ingbo, Zhejiang, China Testing location/procedure...: TL [ ] CBTL [ ] SMT [ ] TM [ ] Address... : Applicant s name...: Address... : Test specification: Same as above XI A BEICHEG ELECTROICS CO., LTD JIGYUA 7 ROAD, JIGHE IDUSTRIAL ARK, ORTH DISTRICT,XI'A, CHIA Standard...: E :2010 Test procedure... : on-standard test method...: LVD safety report.a. Test Report Form o... : IEC/E 61010_1 TRF Originator...: TS Master TRF...: Test item description...: Model/Type reference... : Manufacturer...: Address... : Trademark... : Rating(s)... : Digital Multimeter VICTOR 81B, VICTOR 81D XI A BEICHEG ELECTROICS CO., LTD JIGYUA 7 ROAD, JIGHE IDUSTRIAL ARK, ORTH DISTRICT,XI'A, CHIA VICTOR 3.0Vdc (R03 UM-4/AAA battery)

3 Report o. S age 2 of 77 Test item particulars... : Type of item tested...: Measuring equipment Description of equipment function... : Installation/overvoltage category...: Measure for the voltage, current, resistance, temperature. CAT III 600V ollution degree... : ollution degree 2 Environmental rating...: Equipment mobility...: Connection to mains supply...: Operating conditions...: Marked degree of protection to IEC : Temperature: 0 ~ +40 C ortable equipment one Continuous I20 Accessories and detachable parts included in the evaluation... : Options...: /A /A Test case verdicts... : Test case does not apply to the test object...: Test object does meet the requirement... : Test object does not meet the requirement...: /A(ot applicable) (ass) F(Fail) Testing... : Date of receipt of test item... : March 27, 2017 Date (s) of performance of tests... : March 27 march 30, 2017 General remarks: This report shall not be reproduced, except in full, without the written approval of the issuing testing laboratory. The test results presented in this report relate only to the item(s) tested. "(see remark #)" refers to a remark appended to the report. "(see Annex #)" refers to an annex appended to the report. "(see Form A.#)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. Remark: Two modles have same electrical parts. All tests were performed on model VICTOR 81B which cover other models. TRF o. IEC61010_1F

4 Report o. S age 3 of 77 Copy of marking plate: (for example model: VICTOR 81B) 1) Marking label for model VICTOR 81B. Digital Multimeter Model : VICTOR 81B Rating: 3.0Vdc (R03 UM-4/AAA battery) XI'A BEICHEG ELECTROICS CO., LTD Importer name:xxx Importer address:xxx 2) Below warning statement and symbol were marked on appliance Summary of test results (information/comments): - This Digital Multimeter is designed for measure the voltage, current, resistance, temperature. - The max. temperature of the appliance is 40 ºC, declared by the manufacturer. - EUT complies with E : TRF o. IEC61010_1F

5 Report o. S age 4 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict TABLE: 1 - Documents attached to this report Document o. Document description age umbers Appendix 2 hoto documentation TABLE: 2 - Test equipment list Item Manufacturer Equipment Calibration date Comments - - Model o. Last 1 Due *ote: Appendix 1 (age 69-73) 1) or interval between calibrations. Unique component reference or location (including drawing reference if required) TABLE: 3 List of components and circuits relied on for safety Manufacturer (OTE 1) art number RATIG (OTE 2) Evidence of acceptance (OTE 3) Enclosure Various Various V-0 UL CB Various Various V-0, 130 C UL Internal cord Various Various 22AWG,200 UL -alt. Various Various 22AWG,200 UL Battery Various R03 DC 1.5V CB TC Various Various --- VDE Fuse Various Various 10A,250V VDE OTE 1 - List all manufacturers concerned. OTE 2 - Electrical, mechanical, flammability, etc. OTE 3 - Licence number, file number or other documentary evidence of acceptance TRF o. IEC61010_1F

6 Report o. S age 5 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict 4.4 Testing in SIGLE FAULT CODITIOS Fault tests (see Form A.1 and A.2) Application of SIGLE FAULT CODITIOS FAULT CODITIOS SHALL ICLUDE THOSE SECIFIED I TO (see Form A.1 and A.2) ROTECTIVE IMEDACE ROTECTIVE CODUCTOR Equipment or parts for short-term or intermittent operation Motors Capacitors o such capacitor MAIS transformers Short circuit Overload Outputs Equipment for more than one supply Cooling Heating devices Insulation between circuits and parts Interlocks Voltage selectors Duration of tests (see Form A.1 and A.2) Conformity after application of fault conditions (see Form A.1; A.2; A.8, A.14) 5 MARKIG AD DOCUMETATIO General Required equipment markings are: visible: From the exterior; or Marking for double insulation, caution, CE are marked on apparatus surface. After removing a cover; or o such parts used Opening a door Ditto After removal from a rack or panel Ditto ot put on parts which can be removed by an operator TRF o. IEC61010_1F

7 Report o. S age 6 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Letter symbols (IEC 60027) used Graphic symbols (IEC : Table 1) used Refer to rating label Identification Equipment is identified by: a) Manufacturer s or supplier s name or trademark See page 1 b) Model number, name or other means See page 1 Manufacturing location identified Only one factory MAIS supply Equipment is marked as follows: a) ature of supply: Supplied by battery 1) a.c. RATED MAIS frequency or range of frequencies... : 2) d.c. with symbol 1 b) RATED supply voltage(s) or range...: DC3.0V C) Max. RATED power (W or VA) or input current...: The marked value not less than 90 % of the maximum value If more than one voltage range: Separate values marked; or Values differ by less than 20 % (see Form A.3) d) OERATOR-set for different RATED supply voltages: Indicates the equipment set voltage ortable equipment indication is visible from the exterior Changing the setting changes the indication e) Accessory MAIS socket-outlets accepting standard MAIS plugs are marked: With the voltage if it is different from the MAIS supply voltage...: For use only with specific equipment If not marked for specific equipment it is marked with: The maximum rated current or power; or Symbol 14 with full details in the documentation Fuses TRF o. IEC61010_1F

8 Report o. S age 7 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Operator replaceable fuse marking (see also 5.4.5)...: See CDF(TABLE: 3 List of components and circuits relied on for safety) TERMIALS, connections and operating devices General Where necessary for safety, indication of purpose of TERMIALS, connectors, controls and indicators marked If insufficient space, symbol 14 used ush-buttons and actuators of emergency stop devices and indicators: used only to indicate a warning of danger or the need for urgent action coloured red coded as specified in IEC Supplementary means of coding provided, if meaning of colour relates (see IEC 60073): to safety of persons; or safety of the environment TERMIALS MAIS supply TERMIAL identified Other TERMIAL marking: a) FUCTIOAL EARTH TERMIALS (symbol 5 used) b) ROTECTIVE CODUCTOR TERMIALS: Symbol 6 is placed close to or on the TERMIAL; or art of appliance inlet c) TERMIALS of control circuits (symbol 7 used) d) HAZARDOUS LIVE TERMIALS supplied from the interior Standard MAIS socket outlet; or RATIGS marked; or Symbol 14 used Switches and circuit breakers If disconnecting device, off position clearly marked If push-button used as power supply switch: Symbol 9 and 15 used for on-position Symbol 10 and 16 used for off-position TRF o. IEC61010_1F

9 Report o. S age 8 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict TRF o. IEC61010_1F air of symbols 9, 15 and 10, 16 close together Equipment protected by DOUBLE ISULATIO or REIFORCED ISULATIO rotected throughout (symbol 11 used) Only partially protected (symbol 11 not used) Field-wiring TERMIAL boxes If TERMIAL or ECLOSURE exceeds 60 C: Cable temperature RATIG marked... : Marking visible before and during connection or beside TERMIAL 5.2 Warning markings Visible when ready for ORMAL USE Are near or on applicable parts Symbols and text correct dimensions and colour: a) symbols min 2,75 mm and text 1,5 mm high and contrasting in colour with background b) symbols and text moulded, stamped or engraved in material min. 2,0 mm high and 0.5 mm depth or raised if not contrasting in colour If necessary marked with symbol 14 Statement to isolate or disconnect if access by using a tool to HAZARDOUS LIVE parts is permitted 5.3 Durability of markings The required markings remain clear and legible in ORMAL USE (see Form A.4) 5.4 Documentation General Equipment is accompanied by documentation for safety purposes for OERATOR or RESOSIBLE BODY Safety documentation for service personnel authorized by the manufacturer Documentation necessary for safe operation is provided in printed media or in electronic media if available at any time rovided in user s manual. Documentation includes: a) intended use b) technical specification

10 Report o. S age 9 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict TRF o. IEC61010_1F c) name and address of manufacturer or supplier d) Information specified in to See to e) information to mitigate residual RISK (see also subclause 17) f) accessories for safe operation of the equipment specified g) guidance provided to check correct function of the equipment, if incorrect reading may cause a HAZARD from harmful or corrosive substances of HAZARDOUS live parts h) instructions for lifting and carrying Warning statements and a clear explanation of warning symbols: rovided in the documentation; or Information is marked on the equipment Equipment ratings Documentation includes: a) Supply voltage or voltage range... : DC3.0V Frequency or frequency range... : ower or current rating... : b) Description of all input and output connections in accordance to a) c) RATIG of insulation of external circuits in accordance to b) d) Statement of the range of environmental conditions (see 1.4) Environmental indicated e) Degree of protection (IEC 60529) I20 f) if impact rating less than 5 J: IK code in accordance to IEC marked or symbol 14 of table 1 marked, with RATED energy level and test method stated Equipment installation rovided in user s manual Documentation includes instructions for: a) assembly, location and mounting requirements b) protective earthing c) connections to supply d) permanently connected equipment: 1) Supply wiring requirements

11 Report o. S age 10 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict 2) If external switch or circuit-breaker, requirements and location recommendation e) ventilation requirements f) special services (e. g. air, cooling liquid) g) Instructions relating to sound level Equipment operation See below. Instructions for use include: a) identification and description of operating controls b) positioning for disconnection c) instructions for interconnection d) specification of intermittent operation limits e) explanation of symbols used Symbols have explanation in user manual. f) replacement of consumable materials Battery g) cleaning and decontamination Use soft dry cloth without any solvents or water. h) Listing of any poisonous or injurious gases and quantities i) RISK reduction procedures relating to flammable liquids (see 9.5) j) RISK reduction procedures relating burn from surfaces permitted to exceed limits of 10.1 Additional precautions for IEC conforming equipment in regard to moistures and liquids A statement about protection impairment if used in a manner not specified by the manufacturer Equipment maintenance Instructions for RESOSIBLE BODY include: Instructions sufficient in detail permitting safe maintenance and inspection and continued safety: Instruction against the use of detachable MAIS supply cord with inadequate rating Specific battery type of user replaceable batteries Any manufacturer specified parts Rating and characteristics of fuses Instructions include following subjects permitting safe servicing and continued safety: TRF o. IEC61010_1F

12 Report o. S age 11 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict a) product specific RISKS may affect service personnel b) protective measures for these RISKS c) verification of the safe state after repair Integration into systems or effects resulting from special conditions Aspects described in documentation 6 ROTECTIO AGAIST ELECTRIC SHOCK 6.1 General (see Form A.5) Requirements TRF o. IEC61010_1F rotection against electric shock maintained in ORMAL CODITIO and SIGLE FAULT CODITIO ACCESSIBLE parts not HAZARDOUS LIVE Voltage, current, charge or energy below the limits in ORMAL CODITIO and in SIGLE FAULT CODITIO between: ACCESSIBLE parts and earth two ACCESSIBLE parts on same piece of the equipment within a distance of 1,8 m Conformity is checked by the determination of 6.2 and 6.3 followed by the tests of 6.4 to 6.11 All accessible parts are not hazards live Exceptions Following HAZARDOUS LIVE parts may be accessible to an OERATOR: a) parts of lamps and lamp sockets after lamp removal b) parts to be replaced by operator only by the use of tool and warning marking Those parts not HAZARDOUS LIVE 10 s after interruption of supply Capacitance test if charge is received from internal capacitor (see Forms A.6 ) (see Forms A.6 and A.7) 6.2 Determination of accessible parts (see Form A.6) General Unless obviously determination of accessible parts as specified in to Examination - with jointed test finger (as specified B.2)

13 Report o. S age 12 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict - with rigid test finger (as specified B.1) and a force of Openings above parts that are HAZARDOUS LIVE - test pin with length of 100 mm and 4 mm in diameter applied Openings for pre-set controls - test pin with length of 100 mm and 4 mm in diameter applied 6.3 Limit values for ACCESSIBLE parts Levels in ORMAL CODITIO (see Form A.7) a) Voltage limits less than 33 V r.m.s. and 46,7 V peak or 70 V d.c. for wet locations voltage limits less than 16 V r.m.s. and 22,6 V peak or 35 V d.c. Voltages are not HAZARDOUS LIVE the levels of: b) Current less than 0,5 ma r.m.s. for sinusoidal, 0,7 ma peak non sinusoidal or mixed frequencies or 2 ma d.c. when measured with measuring circuit A.1 or A.2 if less than 100 Hz or for wet locations measuring circuit A.4 used c) Levels of capacitive charge or energy less: 1) 45 µc for voltages up to 15 kv peak or d.c. or line A of Figure 3 2) 350 mj stored energy for voltages above 15 kv peak or d.c Levels in SIGLE FAULT CODITIO (see Form A.7) a) Voltage limits less than 33 V r.m.s. and 46,7 V peak or 70 V d.c. for wet locations voltage limits less than 16 V r.m.s. and 22,6 V peak or 35 V d.c. Voltages are not HAZARDOUS LIVE the levels of: b) Current less than 0,5 ma r.m.s. for sinusoidal, 0,7 ma peak non sinusoidal or mixed frequencies or 2 ma d.c. when measured with measuring circuit A.1 or A.2 if less than 100 Hz or for wet locations measuring circuit A.4 used c) Levels of capacitive charge or energy less: TRF o. IEC61010_1F

14 Report o. S age 13 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict TRF o. IEC61010_1F 1) 45 µc for voltages up to 15 kv peak or d.c. or line A of Figure 3 2) 350 mj stored energy for voltages above 15 kv peak or d.c. 6.4 rimary means of protection ACCESSIBLE parts prevented from being HAZARDOUS LIVE by one or more of following means: a) ECLOSURES or ROTECTIVE BARRIERS (see 6.4.2) b) BASIC ISULATIO (see 6.4.3) c) Impedance (see 6.4.4) ECLOSURES or ROTECTIVE BARRIERS (see Form A.13) - meet rigidity requirements of meet requirements for BASIC ISULATIO, if protection is provided by insulation - meet requirements of 6.7 for CREEAGE and CLEARACES between ACCESSIBLE parts and HAZARDOUS live parts, if protection is provided by limited access BASIC ISULATIO (see Form A.13) - meet CLEARACE, CREEAGE DISTACE and solid insulation requirements of Impedance (see Form A.12) Impedance used as primary means of protection meets all of following requirements: a) limits current or voltage to level of (see Form A.7) b) RATED for maximum WORKIG VOLTAGE and the amount of power it will dissipate c) CLEARACE, CREEAGE DISTACE between terminations of the impedance meet requirements of BASIC ISULATIO of 6.7 (see Form A.13) 6.5 Additional means of protection in case of SIGLE FAULT CODITIO Accessible parts are prevented from becoming hazardous live by the primary means of protection and supplemented by one of: a) ROTECTIVE BODIG (see 6.5.2) b) SULEMETARY ISULATIO (see 6.5.3) c) automatic disconnection of the supply (see 6.5.5) d) current- or voltage-limiting device (see 6.5.6) Alternatively one of the single means of protection is used:

15 Report o. S age 14 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict e) REIFORCED ISULATIO (see 6.5.3) f) ROTECTIVE IMEDACE (see 6.5.4) rotective bonding (see Form A.9, A.10 and A.11) Accessible conductive parts, may become harzardous live in single fault condition: Bonded to the protective conductor terminal; or Separated by conductive screen or barrier bonded to protective conductor terminal Integrity of protective bonding A) ROTECTIVE BODIG consists of directly connected structural parts or discrete conductors or both; and withstands thermal and dynamic stresses b) Soldered connections: Independently secured against loosening ot used for other purposes c) Screw connections are secured D) ROTECTIVE BODIG not interrupted; or exempted as removable part carries MAIS SULY IUT connection e) Any moveable ROTECTIVE BODIG connection specifically designed, and meets f) o external metal braid of cables used (not regarded as ROTECTIVE BODIG) G) IF MAIS SULY ASSES THROUGH: Means provided for passing protective conductor; Impedance meets H) rotective conductors bare or insulated, if insulated, green/yellow Exceptions: 1) earthing braids; 2) internal protective conductors etc.; Green/yellow not used for other purposes TERMIAL suitable for connection of a ROTECTIVE CODUCTOR, and meets ROTECTIVE CODUCTOR TERMIAL a) Contact surfaces are metal b) Appliance inlet used TRF o. IEC61010_1F

16 Report o. S age 15 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict C) For rewirable cords and ERMAETLY COECTED EQUIMET, ROTECTIVE CODUCTOR TERMIAL is close to MAIS supply TERMIALS d) If no MAIS supply is required, any ROTECTIVE CODUCTOR TERMIAL: Is near terminals of circuit for which protective earthing is necessary External if other terminals external e) Equivalent current-carrying capacity to MAIS supply TERMIALS (see Form A.9) f) If plug-in, makes first and breaks last g) If also used for other bonding purposes, protective conductor: Applied first; Secured independently; Unlikely to be removed by servicing h) ROTECTIVE CODUCTOR of measuring circuit: 1) Current RATIG equivalent to measuring circuit TERMIAL; 2) ROTECTIVE BODIG: ot interrupted; or i) FUCTIOAL EARTH TERMIALS allow independent connection j) If a binding screw used for ROTECTIVE CODUCTOR TERMIAL: Suitable size for bond wire ot smaller than M 4 (o. 6) At least 3 turns of screw engaged asses tightening torque test (see Form A.9) k) Contact pressure not capable being reduced by deformation of materials Impedance of ROTECTIVE BODIG of plugconnected equipment Impedance between ROTECTIVE CODUCTOR TERMIAL and each ACCESSIBLE part where ROTECTIVE BODIG is specified, is: less than 0,1 Ohm; or less than 0,2 Ohm if equipment is provided with non detachable cord (see Form A.10) TRF o. IEC61010_1F

17 Report o. S age 16 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Bonding impedance of ERMAETLY COECTED EQUIMET (see Form A.10) Transformer ROTECTIVE BODIG screen (see Form A.11) TRF o. IEC61010_1F Transformer provided with screen for protective bonding: screen bonding consists of directly connected structural parts or discrete conductors or both; and withstands thermal and dynamic stresses (see a ) screen bonding with soldered connection (see b ) is: - Independently secured against loosening - ot used for other purposes SULEMETARY and REIFORCED ISULATIO - meet CLEARACE, CREEAGE DISTACE and solid insulation requirements of ROTECTIVE IMEDACE (see Form A.12) Limits current or voltage to level of in ORMAL and to level of in SIGLE FAULT CODITIO CLEARACE, CREEAGE DISTACE between terminations of the impedance meet requirements of DOUBLE or REIFORCED ISULATIO of 6.7 The protective impedance consists of one or more of the following: a) appropriate single component suitable for safety and reliability for protection, it is: (see Form A.13) (see Table 3 and Form A.12) 1) RATED twice the maximum WORKIG VOLTAGE 2) resistor RATED for twice the power dissipation for maximum WORKIG VOLTAGE b) combination of components Single electronic device not used as ROTECTIVE IMEDACE Automatic disconnection of the supply a) RATED to disconnect the load within time specified in Figure 2 b) RATED for the maximum load conditions of the equipment Current- or voltage limiting devices (see Form A.12) Device complies with all of: a) RATED to limit the current or voltage to the level of (see Form A.8)

18 Report o. S age 17 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict b) RATED for the maximum working voltage; and RATED for the maximum operational current if applicable c) CLEARACE, CREEAGE DISTACE between (see Form A.13) terminations of the impedance meet requirements of SULEMETARY ISULATIO of Connections to external circuits Connections do not cause ACCESSIBLE parts of the following to become HAZARDOUS LIVE in ORMAL CODITIO or SIGLE FAULT CODITIO: - the external circuits - the equipment rotection achieved by separation of circuits; or short circuit of separation does not cause a HAZARD Instructions or markings for each terminal include: A) RATED conditions for TERMIAL B) Required RATIG of external circuit ISULATIO TERMIALS for external circuits TERMIALS which receive a charge from an internal capacitor are not HAZARDOUS LIVE after 10 s of interrupting supply connection (see Form A.7) Circuits with terminals which are HAZARDOUS LIVE These circuits are: ot connected to ACCESSIBLE conductive parts; or Connected to ACCESSIBLE conductive parts, but are not MAIS circuits and have one TERMIAL contact at earth potential o ACCESSIBLE conductive parts are HAZARDOUS LIVE ACCESSIBLE terminals for stranded conductors o RISK of accidental contact because: Located or shielded Self-evident or marked whether or not connected to ACCESSIBLE conductive parts ACCESSIBLE TERMIALS will not work loose 6.7 Insulation requirements (see Form A.5) The nature of insulation TRF o. IEC61010_1F

19 Report o. S age 18 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Insulation between ACCESSIBLE parts or between separate circuits consist of CLEARACES, CREEAGE DISTACES and solid insulation if provided as protection against a HAZARD CLEARACES TRF o. IEC61010_1F Required CLEARACES reflecting factors of (see Form A.5) Equipment rated for operating altitude greater than 2000 m correction factor of Table 3 of applied CREEAGE DISTACES Required CLEARACES reflecting factors of (see Form A.5) CTI material group reflected by requirements CTI test performed Solid insulation Required CLEARACES reflecting factors of (see Form A.5) Requirements for insulation according to type of circuit A) MAIS circuits of OVERVOLTAGE CATEGORY II up to nominal supply voltage of 300 V B) Secondary circuits separated from circuits defined in a) by transformer C) K.1 MAIS circuits of OVERVOLTAGE CATEGORY III and IV or OVERVOLTAGE CATEGORY II over 300 V D) K.2 Secondary circuits separated from circuits defined in a) by transformer (see Form A.5) E) K.3 Circuits having one or more of: 1) maximum TRASIET OVERVOLTAGE is limited to known level below the level of MAIS CIRCUIT 2) maximum TRASIET OVERVOLTAGE above the level of MAIS CIRCUIT 3) WORKIG VOLTAGE is the sum of more than one circuit or a mixed voltage 4) WORKIG VOLTAGE includes recurring peak voltage, may include non-sinusoidal or nonperiodic waveform 5) WORKIG VOLTAGE with a frequency above 30 khz Insulation for MAIS CIRCUITS of OVERVOLTAGE CATEGORY II with a nominal supply voltage up to 300 V CLEARACES and CREEAGE DISTACES (see Form A.13)

20 Report o. S age 19 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict TRF o. IEC61010_1F Values for MAIS CIRCUITS of table 4 are met Coatings to achieve reduction to OLLUTIO DEGREE I comply with requirements of Annex H Solid insulation Withstands electrical and mechanical stresses in normal use and all RATED environmental conditions of 1.4 Equipment passed voltage tests of with values of Table 5 Complies as applicable: (see Form A.14) A) ECLOSURE or ROTECTIVE BARRIER Clause 8 b) moulded and potted parts requirements of C) inner layers of printed wiring boards requirements of D) thin-film insulation requirements of Moulded and potted parts Conductors between same two layers are separated by at least 0,4 mm after moulding is completed Inner insulation layers of printed wiring boards Separated by at least 0,4 mm between same two layers REIFORCED ISULATIO have adequate electric strength; one of following methods used: a) thickness at least 0,4 mm b) insulation is assembled of minimum two separate layers, each RATED for test voltage of Table 5 for BASIC ISULATIO C) insulation is assembled of minimum two separate layers, where the combination is rated for test voltage of Table 5 for REIFORCED ISULATIO Thin-film insulation Conductors between same two layers are separated by applicable CLEARACES and CREEAGE DISTACES REIFORCED ISULATIO have adequate electric strength; one of following methods used: a) thickness at least 0,4 mm b) insulation is assembled of min two separate layers, each RATED for test voltage of Table 5 for BASIC ISULATIO

21 Report o. S age 20 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict C) insulation is assembled of min three separate layers, where the combination of two layers passed voltage tests of with values of Table 5 for REIFORCED ISULATIO Insulation for secondary circuits derived from MAIS of OVERVOLTAGE CATEGORY II up to 300 V Secondary circuits where separation from MAIS CIRCUITS is achieved by a transformer providing: (see Form A.14) - REIFORCED ISULATIO - DOUBLE ISULATIO - screen connected to the ROTECTIVE CODUCTOR TERMIAL CLEARACES a) meet the values of Table 6 for BASIC ISULATIO and SULEMETARY ISULATIO; or twice the values of Table 6 for REIFORCED ISULATIO or B) pass the voltage tests of 6.8 with values of Table 6; with following adjustments: 1) values for REIFORCED ISULATIO are 1,6 times the values for BASIC ISULATIO 2) if operating altitude is greater than 2000 m values of CLEARACES multiplied with factor of Table 3 3) minimum CLEARACE is 0,2 mm for OLLUTIO DEGREE 2 and 0,8 mm for OLLUTIO DEGREE 3 (see Form A.14) CREEAGE DISTACES Based on WORKIG VOLTAGE meets the values of Table 7 for BASIC and SULEMETARY ISULATIO Values for REIFORCED ISULATIO are twice the values of BASIC ISULATIO Coatings to achieve reduction to OLLUTIO DEGREE I comply with requirements of Annex H Solid insulation Withstands electrical and mechanical stresses in normal use and all RATED environmental conditions of 1.4 a) Equipment passed voltage test of for 5 s with VALUES of Table 6 for BASIC and SULEMETARY ISULATIO (see Form A.14) TRF o. IEC61010_1F

22 Report o. S age 21 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict values for REIFORCED ISULATIO are 1,6 times the values of BASIC ISULATIO b) if WORKIG VOLTAGE exceeds 300 V, equipment passed voltage test of for 1 min with a test voltage of 1,5 times working voltage for BASIC or SULEMETARY ISULATIO value for REIFORCED ISULATIO are twice the WORKIG VOLTAGE Complies as applicable: (see Form A.14) 1) ECLOSURE or protective barrier Clause 8 2) moulded and potted parts requirements of ) inner layers of printed wiring boards requirements of ) thin-film insulation requirements of Moulded and potted parts Conductors between same two layers are separated by applicable distances of Table Inner insulation layers of printed wiring boards Separated by at least by applicable distances of Table 8 between same two layers REIFORCED ISULATIO have adequate electric strength; one of following methods used: a) thickness at least applicable distance of Table 8 b) insulation is assembled of minimum two separate layers, each RATED for test voltage of Table 6 for BASIC ISULATIO C) insulation is assembled of min two separate layers, where the combination is rated for 1,6 times the test voltage of Table Thin-film insulation Conductors between same two layers are separated by applicable CLEARACES and CREEAGE DISTACES REIFORCED ISULATIO have adequate electric strength; one of following methods used: a) thickness at least applicable distance of Table 8 b) insulation is assembled of min two separate layers, each RATED for test voltage of Table 6 for BASIC ISULATIO TRF o. IEC61010_1F

23 Report o. S age 22 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict TRF o. IEC61010_1F C) insulation is assembled of min three separate layers, where the combination of two layers passed voltage tests with 1,6 time values of Table 6: a.c. test of ; or d.c. test of for circuits stressed only by d.c. voltages (see Form A.14) 6.8 rocedure for dielectric strength tests (see Form A.5 and A.14) 6.9 Constructional requirements for protection against electric shock If a failure could cause a HAZARD: a) Security of wiring connections b) Screws securing removable covers c) Accidental loosening d) CREEAGE and CLEARACES not reduced below the values of basic insulation by loosening Material not to be used for safety relevant insulation: Easily damaged materials not used on-impregnated hydroscopic materials not used Colour coding Green-and-yellow insulation shall not be used except: a) protective earth conductors; b) protective bonding conductors; c) potential equilization conductors; d) functional earth conductors 6.10 Connection to MAIS supply source and connections between parts of equipment MAIS supply cords RATED for maximum equipment current (see 5.1.3c) Cable complies with IEC or IEC Heat-resistant if likely to contact hot parts Temperature RATIG (cord and inlet)... : Green/yellow used only for connection to ROTECTIVE CODUCTOR TERMIALS Detachable cords with IEC MAIS connectors: Conform to IEC 60799; or Have the current RATIG of the MAIS connector

24 Report o. S age 23 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Fitting of non-detachable MAIS supply cords Cord entry Inlet or bushing smoothly rounded; or Insulated cord guard protruding >5D Cord anchorage rotective earth conductor is the last to take the strain a) Cord is not clamped by direct pressure from a screw b) Knots are not used c) Cannot push the cord into the equipment to cause a HAZARD d) o failure of cord insulation in anchorage with metal parts e) ot to be loosened without a tool f) Cord replacement does not cause a HAZARD and method of strain relief is clear ush-pull and or torque test (see Form A.15) lugs and connectors MAIS supply plugs, connectors etc., conform with relevant specifications If equipment supplied at voltages below a) or from a sole source: lugs of supply cords do not fit MAIS sockets above rated SULY voltage MAIS type plugs used only for connection to MAIS supply lug pins which receive a charge from an internal capacitor (see Form A.7) Accessory MAIS socket outlets: a) Marking if accepts a standard MAIS plug (see 5.1.3e) b) Input has a protective earth conductor if outlet has EARTH TERMIAL COTACT 6.11 Disconnection from supply source Disconnects all current carrying conductors Exceptions Supplied by a small battery Requirements according to type of equipment TRF o. IEC61010_1F

25 Report o. S age 24 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict ERMAETLY COECTED EQUIMET and multiphase equipment: TRF o. IEC61010_1F Employs switch or circuit-breaker If switch or circuit-breaker is not part of the equipment, documentation requires: a) Switch or circuit-breaker to be included in building installation b) Suitable location easily reached c) Marking as disconnecting for the equipment Single-phase cord-connected equipment Equipment is provided with one of the following: a) Switch or circuit-breaker b) Appliance coupler (disconnectable without tool) c) Separable plug (without locking device) Disconnecting devices Electrically close to the SULY Switches and circuit-breakers When used as disconnection device: Meets IEC and IEC Marked to indicate function... : ot incorporated in MAIS cord Does not interrupt ROTECTIVE EARTH CODUCTOR Appliance couplers and plugs Where an appliance coupler or separable plug is used as the disconnecting device (see ): Readily identifiable and easily reached by the operator Single-phase portable equipment cord length not more than 3 m ROTECTIVE EARTH CODUCTOR connected first and disconnected last 7 ROTECTIO AGAIST MECHAICAL HAZARDS 7.1 Equipment does not cause a mechanical HAZARD in ORMAL nor in SIGLE FAULT CODITIO Conformity is checked by 7.2 to Sharp edges Easily touched parts are smooth and rounded

26 Report o. S age 25 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Do not cause injury during ORMAL USE and Do not cause injury during SIGLE FAULT CODITIO 7.3 Moving parts HAZARDS from moving parts limited to a tolerable level with the conditions specified in and RISK assessment in accordance with carried out Exceptions Access to HAZARDOUS moving parts permitted under following circumstances: a) obviously intended to operate on parts or materials outside of the equipment inadvertent touching of moving parts minimized by equipment design (e.g. guards or handles) b) If operator access is unavoidable outside normal use following precautions have been taken: 1) Access requires TOOL 2 ) Statement about training in the instructions 3 ) Warning markings on covers prohibiting access by untrained operators or symbol 14 with full details in documentation RISK assessment for mechanical HAZARDS to body parts RISK is reduced to a tolerable level by protective measures as specified in Table 12 Minimum protective measures: A. Low level measures B. Moderate measures C. Stringent measures Limitation of force and pressure (see Form A.16) Following levels are met in normal and single fault condition: Continuous contact pressure below 50 / cm² with force below 150 Temporary force below 250 for an area at least of 3 cm² for a maximum duration of 0,75 s Gap limitations between moving parts (see Form A.16) Access normally allowed TRF o. IEC61010_1F

27 Report o. S age 26 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict If levels of exceeded and body part may be inserted minimum gap as specified in Table 13 assured in ORMAL and in SIGLE FAULT CODITIO Access normally prevented Maximum gap as specified in Table 14 assured in ORMAL and in SIGLE FAULT CODITIO 7.4 Stability Equipment not secured to building structure is physical stable Stability maintained after opening of drawers etc. by automatic means, or warning marking requires the application of means Compliance checked by following tests as applicable: a) 10 tilt test for other than handheld equipment b) multi-directional force test for equipment exceeds height of 1 m and mass of 25 kg c) downward force test for floor-standing equipment d) overload test with 4 times maximum load for castor or support that supports greatest load e) castor or support that supports greatest load removed from equipment 7.5 rovisions for lifting and carrying Equipment more than 18 kg : Has means for lifting or carrying; or Directions in documentation Handles or grips Handles or grips withstand four times weight Lifting devices and supporting parts Rated for maximum load; or tested with four times maximum static load 7.6 Wall mounting Mounting brackets withstand four times weight 7.7 Expelled parts Equipment contains or limits the energy rotection not removable without the aid of a tool 8 RESISTACE TO MECHAICAL STRESSES TRF o. IEC61010_1F

28 Report o. S age 27 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict 8.1 Equipment does not cause a HAZARD when subjected to mechanical stresses in ORMAL USE ormal protection level is 5 J Levels below 5 J but not less than 1 J are acceptable if all of following criteria are met: a) lower level justified by RISK assessment of manufacturer b) equipment installed in its intended application is not easily touched c) only occasional access during ORMAL USE d) IK code in accordance to IEC marked or symbol 14 used with full information in the documentation For non-metallic ECLOSURES rated below 2 C ambient temperature value chosen for minimum rated temperature Impact energies between IK values, the IK code marked for nearest lower value Conformity is checked by performing following tests: 1) static test of ) impact test of with 5 J except for HAD- HELD EQUIMET if impact energy not selected to 5 J alternate method of IEC used 3) drop test of or except for FIXED and EQUIMET with mass over 100 kg Equipment rated with an impact rating of IK 08 that obviously meets the criteria After the tests inspection with following results: - HAZARDOUS LIVE parts above the limits of not ACCESSIBLE - insulation pass the voltage tests of 6.8 (see Form A.24) i) no leaks of corrosive and harmful substances ii) ECLOSURE shows no cracks resulting in a HAZARD iii) CLEARACES not less than their permitted values iv) insulation of internal wiring remains undamaged v) ROTECTIVE BARRIERS not damaged or loosened vi) o moving parts exposed, except permitted by 7.3 TRF o. IEC61010_1F

29 Report o. S age 28 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict vii) no damage which could cause spread of fire 8.2 ECLOSURE rigidity test Static test - 30 with 12 mm rod to each part of ECLOSURE - in case of doubt test conducted at maximum RATED ambient temperature Impact test Impact applied to any part of ECLOSURE causing a HAZARD if damaged Impact energy level and corresponding IK code... : on-metallic ECLOSURES cooled to minimum RATED ambient temperature if below 2 C 8.3 Drop test Other than HAD-HELD and DIRECT-LUG-I EQUIMET Tests conducted with a drop height or angle of...: HAD-HELD and DIRECT-LUG-I EQUIMET on-metallic ECLOSURES cooled to minimum RATED ambient temperature if below 2 C Drop test conducted with an height of 1 m 9 ROTECTIO AGAIST THE SREAD OF FIRE 9.1 o spread of fire in ORMAL and SIGLE FAULT CODITIO TRF o. IEC61010_1F MAIS supplied equipment meets requirements of 9.6 additionally Conformity is checked by minimum one or a combination of the following (see Figure 11): (see Form A.17) a) Fault test of 4.4; or (see Form A.1 and Form A.2) b) Application of 9.2 (eliminating or reducing the sources of ignition); or c) Application of 9.3 (containment of fire within the equipment) 9.2 Eliminating or reducing the sources of ignition within the equipment a) 1) Limited-energy circuit (see 9.4); or 2) BASIC ISULATIO provided for parts of different potential; or (see Form A.5 and A.14) Bridging the insulation does not cause ignition (see Form A.2)

30 Report o. S age 29 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict b) Surface temperature of liquids and parts (see 9.5) c) o ignition in circuits designed to produce heat (see Form A.2) 9.3 Containment of the fire within the equipment, should it occur a) Energizing of the equipment is controlled by an operator held switch b) ECLOSURE is conform with constructional requirements of 9.3.1; and Requirements of 9.5 are met Constructional requirements a) Connectors and insulating material have flammability classification V-2 or better b) Insulated wires and cables are flame retardant (VW-1 or equivalent) (see Table: 3 or Form A.18) (see Table: 3 or Form A.18) c) ECLOSURE meets following requirements: (see Form A.17) 1) Bottom and sides in arc of 5 (see Figure 13) to non-limited circuits (9.4) meets: i) no openings; or ii) perforated as specified in Table 16; or iii) metal screen with a mesh; or iv) baffles as specified in Figure 12 2) Material of ECLOSURE and any baffle or flame barrier is made of: Metal (except magnesium); or on-metallic materials have flammability classification V-1 or better 3) ECLOSURE and any baffle or flame barrier have adequate rigidity (see Table: 3 or Form A.18) 9.4 Limited-energy circuit (see Form A.19) a) otential not more than 30 r.m.s. and 42.4 V peak, or 60 V dc 3.0VDC b) Current limited by one of following means: 1) Inherently or by impedance (see Table 17); or 2) Over current protective device (see Table 18); or 3) A regulating network limits also in SIGLE FAULT CODITIO (see Table 17) the output of battery is conside red inherently limited-energy circuit TRF o. IEC61010_1F

31 Report o. S age 30 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict c) Is separated by at least BASIC ISULATIO Fuse or a nonadjustable electromechanical device is used 9.5 Requirements for equipment containing or using flammable liquids Flammable liquids contained in or specified for use with equipment do not cause spread of fire RISK is reduced to a tolerable level : a) The temperature of surface or parts in contact with flammable liquids is 25 C below fire point (see Form A.20) b) The quantity of liquid is limited c) Flames are contained within the equipment Detailed instructions for RISK-reduction provided 9.6 Overcurrent protection Appliance not energized by mains MAIS supplied equipment protected BASIC ISULATIO between MAIS parts of opposite polarity provided Devices not in the protective conductor Fuses or single-pole circuit-breakers not fitted in neutral (multi-phase) (see Form A.14) ERMAETLY COECTED EQUIMET Overcurrent device: Fitted within the equipment; or Specified in manufacturer's instructions Other equipment rotection within the equipment 10 EQUIMET TEMERATURE LIMITS AD RESISTACE TO HEAT 10.1 Surface temperature limits for protection against burns Easily touched surfaces within the limits in ORMAL and in SIGLE FAULT CODITIO: (see Form A.21A) - at an specified ambient temperature of 40 C - for equipment rated above 40 C ambient temperature limits not exceeded raised by the difference to 40 C TRF o. IEC61010_1F

32 Report o. S age 31 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Heated surfaces necessary for functional reasons exceeding specified values: Are recognizable as such by appearance or function; or Are marked with symbol 13 Guards are not removable without tool 10.2 Temperatures of windings Limits not exceeded in: (see Form A.21B) ORMAL CODITIO SIGLE FAULT CODITIO 10.3 Other temperature measurements Following measurements conducted if applicable: (see Form A.21A) a) Value of 60 C of field-wiring terminal box not exceeded b) Surface of flammable liquids and parts in contact with this liquids c) Surface of non-metallic ECLOSURES d) arts made of insulating material supporting parts connected to MAIS supply e) Terminals carrying a current more than 0,5 A 10.4 Conduct of temperature test Tests conducted under reference test conditions and manufacturer s instructions (see Form A.21A) Temperature measurement of heating equipment Tests conducted in test corner (see Form A.21A) Equipment intended for installation in a cabinet or wall Equipment built in as specified in installation instructions (see Form A.21A) 10.5 Resistance to heat Integrity of CLEARACE and CREEAGE DISTACES (see Form A.13) on-metallic ECLOSURES (see Form A.22) Within 10 min after treatment: Equipment subjected to suitable stresses of 8.2 and 8.3 complying with criteria of Insulating material lastic for enclosure a) arts supporting parts connected to MAIS supply Battery operated, not connect to the mains TRF o. IEC61010_1F

33 Report o. S age 32 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict b) TERMIALS carrying a current more than 0.5 A Examination of material data; or in case of doubt: 1) Ball pressure test; or 2) Vicat softening test of ISO ROTECTIO AGAIST HAZARDS FROM FLUIDS 11.1 rotection to OERATORS and surrounding area provided by EQUIMET o fluids used All fluids specified by manufacturer considered 11.2 Cleaning (see Form A.24) 11.3 Spillage (see Form A.24) 11.4 Overflow (see Form A.24) 11.5 Battery electrolyte Battery electrolyte leakage presents no HAZARD 11.6 Specially protected equipment (see Form A.24) 11.7 Fluid pressure and leakage Maximum pressure...: (see Form A.25) Maximum pressure of any part does not exceed RATED Leakage and rupture at high pressure TRF o. IEC61010_1F Fluid containing parts subjected to hydraulic test if: (see Form A.25) a) product of pressure and volume > 200 kal; and b) pressure > 50 ka arts of refrigerating systems meets pressure-related requirements of IEC or IEC Leakage from low-pressure parts (see Form A.25) Overpressure safety device Does not operate in ORMAL USE a) Connected as close as possible to parts intended to be protected b) Easy access for inspection, maintenance and repair c) Adjustment only with TOOL d) o discharge towards person

34 Report o. S age 33 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict e) o HAZARD from deposit of discharged material f) Adequate discharge capacity o shut-off valve between overpressure safety device and protected parts 12 ROTECTIO AGAIST RADIATIO, ICLUDIG LASER SOURCES, AD AGAIST SOIC AD ULTRASOIC RESSURE 12.1 Equipment provides protection 12.2 Equipment producing ionizing radiation Ionizing radiation (see Form A.26) Equipment meets the following requirements: TRF o. IEC61010_1F a) if intended to emit radiation meets requirements of ; or tested, classified and marked in accordance to IEC b) if only emits stray radiation meets requirements of Equipment intended to emit radiation Effective dose rate of radiation measured...: If dose rate exceeds 5 µsv/h marked with the following: a) Symbol 17 (ISO 361) b) Abbreviations of the radionuclides...: c) With maximum dose at 1 m; or...: with dose rate value between 1 µsv/h and 5 µsv/h in m...: Equipment not intended to emit radiation Limit for unintended stray radiation of 1 µsv/h at any easily reached point kept...: Accelerated electrons Compartments opened only by the use of a TOOL 12.3 Ultraviolet (UV) radiation o unintentional HAZARDOUS escape of UV radiation: - checked by inspection; and - evaluation of RISK assessment documentation 12.4 Micro-wave radiation ower density does not exceed 10 W/m 2...:

35 Report o. S age 34 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict 12.5 Sonic and ultrasonic pressure Sound level (see Form A.27) o HAZARDOUS sound emission Maximum sound pressure level measured and calculated for maximum sound power level as specified in ISO 3746 or ISO Instruction describes measures for protection Ultrasonic pressure (see Form A.27) Equipment not intended to emit ultrasound does not exceed limit of 110 db between 20 khz and 100 khz Equipment intended to emit ultrasound: Outside useful beam does not exceed limit of 110 db between 20 khz and 100 khz If inside useful beam above values exceeded: Marked with Symbol 14 of Table 1 and following information in the documentation: a) dimensions of useful beam b) area where ultrasonic pressure exceed 110 db c) maximum sound pressure inside beam area 12.6 Laser sources Equipment meets requirements of IEC ROTECTIO AGAIST LIBERATED GASES, EXLOSIO AD IMLOSIO 13.1 oisonous and injurious gases TRF o. IEC61010_1F o poisonous or injurious gases or substances liberated in ORMAL CODITIO Attached data/test reports demonstrate conformity 13.2 Explosion and implosion Components Components liable to explode: ressure release device provided; or Apparatus incorporates operator protection (see also 7.7) ressure release device: Discharge without danger Cannot be obstructed

36 Report o. S age 35 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Batteries and battery charging (see Form A.28) If explosion or fire HAZARD could occur: rotection incorporated in the equipment; or Instructions specify batteries with built-in protection In case of wrong type of battery used: o HAZARD; or Warning by marking and within instructions Equipment with means to charge rechargeable batteries: Warning against the charging of non-rechargeable batteries; and Type of rechargeable battery indicated; or Symbol 14 used Battery compartment design Single component failure olarity reversal test Implosion of cathode ray tubes If maximum face dimensions > 160 mm...: Intrinsically protected and correctly mounted; or ECLOSURE provides protection: If non-intrinsically protected: Screen not removable without TOOL If glass screen, not in contact with surface of tube 14 COMOETS AD SUBASSEMBLIES 14.1 Where safety is involved, components and subassemblies meet relevant requirements (see Table 3) 14.2 Motors Motor temperatures Does not present a HAZARD when stopped or prevented form starting; or (see Form A.21) TRF o. IEC61010_1F rotected by over-temperature or thermal protection device conform with Series excitation motors Connected direct to device, if over-speeding causes a HAZARD 14.3 Overtemperature protection devices

37 Report o. S age 36 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Devices operating in a SIGLE FAULT CODITIO (see Form A.29) a) Reliable function is ensured B) RATED to interrupt maximum current and voltage c) Does not operate in ORMAL USE If self-resetting device used to prevent a HAZARD, protected part requires intervention before restarting 14.4 Fuse holders o access to HAZARDOUS LIVE parts 14.5 MAIS voltage selecting devices Accidental change not possible 14.6 MAIS transformers tested outside equipment (see Forms A.30 and A.31) 14.7 rinted circuit boards Data shows conformity with V-1 of IEC or better; or V-0 Test shows conformity with V-1 of IEC or better ot applicable for printed wiring boards with limitedenergy circuits (9.4) 14.8 Circuits or components used as transient overvoltage limiting devices Test conducted between each pair of MAIS SULY TERMIALS o HAZARD resulting from rupture or overheating of the component: (see Form A.18) (see Form A.32) - no bridging of safety relevant insulation - no heat to other parts above the self-ignition points 15 ROTECTIO BY ITERLOCKS 15.1 Interlocks are designed to remove a HAZARD before OERATOR exposed 15.2 revention of reactivation 15.3 Reliability Single fault unlikely to occur; or Cannot cause a HAZARD 16 HAZARDS RESULTIG FROM ALICATIO 16.1 REASOABLY FORESEEABLE MISUSE TRF o. IEC61010_1F

38 Report o. S age 37 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict o HAZARDS arising from settings not intended and not described in the instructions Other cases of REASOABLY FORESEEABLE MISUSE addressed by RISK assessment 16.2 Ergonomic aspects Factors giving rise to a HAZARD the RISK assessment is reflecting those aspects: a) limitation of body dimensions b) displays and indicators c) accessibility and conventions of controls d) arrangement of TERMIALS 17 RISK assessment RISK assessment conducted, if HAZARD might arise and not covered by Clauses 6 to 16 TOLERABLE RISK achieved by iterative documented process covering the following: a) RISK analysis Identifies HAZARDS and estimates RISK b) RISK evaluation lan to judge acceptability of resulting RISK level based on the estimated severity and likelihood of a RISK c) RISK reduction Initial RISK reduced by counter measures; Repeated RISK evaluation without new RISKS introduced RISKS remaining after RISK assessment addressed in instructions to RESOSIBLE BODY: Information contained how to mitigate these RISKS Following principles in methods of RISK reduction applied by manufacturer in given order: 1) RISKS eliminated or reduced as far as possible 2) rotective measures taken for RISKS that cannot be eliminated 3) User information about residual RISK due to any defect of the protective measures Indication of particular training is required TRF o. IEC61010_1F

39 Report o. S age 38 of 77 IEC/E Clause Requirement + Test Result - Remark Verdict Specification of the need for personal protective equipment Conformity checked by evaluation of the RISK assessment documentation AEX F ROUTIE TESTS Carried out by manufacturer. Manufacturer s declaration TRF o. IEC61010_1F

40 Report o. S age 39 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Summary of SIGLE FAULT CODITIOS Form A.1 Subclause Title Does not apply SIGLE FAULT CODITIOS not covered by to ROTECTIVE IMEDACE X Carried out X see Form A ROTECTIVE CODUCTOR X see Form A Equipment or parts for short-term or intermittent operation Motors X stopped while fully energized X prevented from starting X one phase interrupted (multi-phase) X Capacitors X MAIS transformers Attach drawing of MAIS transformers showing all protective devices (see Forms A.30 and A.31) Outputs X Equipment for more than one supply X Cooling X air holes closed X fans stopped X coolant stopped X loss of cooling liquid X Heating devices X timer overridden X temperature controller overridden X Insulation between circuits and parts X Interlocks X Voltage selectors X List below all SIGLE FAULT CODITIOS not covered by to : - semi-conductor components shortcircuited. (see Form A.2 for details of tests) X X X Comments TRF o. IEC61010_1F

41 Report o. S age 40 of 77 IEC Clause Requirement Test Result Remark Verdict 4.4 TABLE: Testing in SIGLE FAULT CODITIO Results Form A.2 Fault o. Fault description Td (OTE) How was test terminated Comments 1 Q18A 00:10:00 ormal work, no hazards. Yes 2 R20 00:10:00 ormal work, no hazards. Yes 3 R37 00:10:00 ormal work, no hazards. Yes 4 D1 00:10:00 Unit shutdown, no hazards. Yes Meets OTE Td = Test duration in hh:mm:ss Record dielectric strength test on Form A.14 and temperature tests on Form A.21. Record in the comments column for each test whether carried out during or after SIGLE FAULT CODITIO. TRF o. IEC61010_1F

42 Report o. S age 41 of 77 IEC Clause Requirement Test Result Remark Verdict 5.1.3c) TABLE: MAIS supply Form A.3 Marked rating... : -- V hase... : -- Frequency...: -- Hz Current... : -- A ower... : -- W ower... : -- VA Test Voltage Frequency Current ower in ower in Comments o. V Hz A W VA ote Measurements are only required for marked ratings. TRF o. IEC61010_1F

43 Report o. S age 42 of 77 IEC Clause Requirement Test Result Remark Verdict 5.3 TABLE: Durability of markings Form A.4 Marking method (see OTE) Agent 1) Adhesive label A Water 2) Ink printed B Isopropyl alcohol 70% 3) Laser marked C (specify agent) 4) Filmcoated (plastic foil control panel) D (specify agent) 5) Imprinted on plastic (moulded in) E (specify agent) OTE Where applicable include print method, label material, ink or paint type, fixing method, adhesive and surface to which marking is fixed. Marking location Identification (5.1.2) 1 MAIS supply (5.1.3) -- Marking method (see above) Fuses (5.1.4) 1 terminals and operating devices ( ) -- Switches and circuit breakers (5.1.6) -- Double/reinforced equipment (5.1.7) 5 Field wiring Terminal boxes (5.1.8) -- Warning marking (5.2) 5 Battery charging (13.2.2) -- Method Test agent Remains legible Label loose Curled edges Comments Verdict Verdict Verdict 1 A / B Yes / o Yes / o Yes / o / F / A 1 A / B Yes / o Yes / o Yes / o / F / A 5 A / B Yes / o Yes / o Yes / o / F / A 5 A / B Yes / o Yes / o Yes / o / F / A TRF o. IEC61010_1F

44 Report o. S age 43 of 77 IEC Clause Requirement Test Result Remark Verdict 6 TABLE: rotection against electric shock - Block diagram of systemform A.5 ollution degree... : 2 Location or Insulation type Maximum working description (OTE 1) voltage (OTE 2) Live part and enclosure WB mm Overvoltage category...: II CREEAGE Distance (OTE 3) CTI Other mm CLEARACE (OTE 3) Test voltage CTI mm (OTE 2) V Comments RI 600V - - > > V rms -- fuse (F1) BI 600V > > V rms OTE 1 Type of insulation: OTE 2 - Types of voltage OTE 3 - ISTALLATIO CATEGORIES BI = BASIC ISULATIO eak impulse test voltage (pulse) (OVERVOLTAGE CATEGORIES) DI = DOUBLE ISULATIO r.m.s. or OLLUTIO DEGREES which differ from I = ROTECTIVE IMEDACE d.c. these should be shown under "Comments". RI = Reinforced ISULATIO peak SI = Supplementary ISULATIO Supplementary Information: 6.2 TABLE: List of ACCESSIBLE parts Form A Exceptions 6.2 Determination of ACCESSIBLE parts Item Description Determination method (OTE 5) 1 lastic enclosure, reinforced insulation is provided. Visual, test finger and rigid test finger Exception under (OTE 4) -- OTE 1 Test fingers and pins are to be applied without force unless a force is specified (see 6.2.2) OTE 2 Special consideration should be given to inadequate insulation and high voltage parts (see 6.2) OTE 3 arts are considered to be ACCESSIBLE if they could be touched in the absence of any covering which is not considered to provide suitable insulation (see 6.4). OTE 4 Capacitor test may be required (see Form A.7). OTE 5 The determination methods are: V = visual; R = rigid test finger; J = jointed test finger; 3 = pin 3 mm diameter; 4 = pin 4 mm diameter. TRF o. IEC61010_1F

45 Report o. S age 44 of 77 IEC Clause Requirement Test Result Remark Verdict 6 TABLE: Values in ORMAL CODITIO Form A Exceptions Values in ORMAL CODITIO (see OTE 1) Terminals for external circuit lugs and connections Item Voltage Current Capacitance 10 s / 5 s test (OTE) (see Form A.6) V r.m.s. V peak V d.c. Test circuit A1/A2/A3 ma r.m.s. ma peak ma d.c. C mj V C mj Comments Enclosure A1 0.04mA OTE A 10 s test is specified in a) b). A 5 s test is specified in The capacitance level versus voltage below the limits given from figure 3 of IEC TRF o. IEC61010_1F

46 Report o. S age 45 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Values in SIGLE FAULT CODITIO Form A.8 Item (see Form A.6) Subclause and fault o. (see Form A.2) V r.m.s. Voltage V peak V d.c. Transient (see OTE) V s Test circuit A1/A2/A3 Current ma r.m.s. ma peak ma d.c. Capacitance F (see OTE) Comments Enclosure s-c R A Enclosure s-c R A OTE Transient voltages must be below the limits given from Figure 2 and the capacitance below the limits from figure 3 of IEC TRF o. IEC61010_1F

47 Report o. S age 46 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Cross-sectional area of bonding conductors Form A.9 CODUCTOR LOCATIO CROSS-SECTIOAL AREA mm² VERDICT ass TABLE: Tighting torque test Conductor location Size of screw Tighting torque m Verdict TABLE: Bonding impedance of plug connected equipment Form A.10 ACCESSIBLE part under test Test current A Voltage attained after 1 min V (OTE 2) Calculated resistance (Maximum 0,1 or 0,2 ) (OTE 1) Verdict OTE 1 For none-detachable power cord the impedance between protective conductor plug pin of MAIS cord and each ACCESSIBLE part shall not exceed 0,2 Ohm TABLE: Bonding impedance of permanently connected equipment ACCESSIBLE part under test Test current A Voltage attained after 1 min (maximum 10 V) V Verdict TABLE: Transformer ROTECIVE BODIG screen Form A.11 ACCESSIBLE part under test Test current (see OTE) A Voltage attained after 1 min (maximum 10 V) V Calculated resistance (maximum 0,1 ) Verdict OTE Test current must be twice the value of the overcurrent protection means of the winding. Test is specified in a) or b). TRF o. IEC61010_1F

48 Report o. S age 47 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: protective impedance Form A.12 A single component Component Location Measured Calculated Rated Verdict Comments Working voltage V Current A ower dissipation W Working voltage V ower dissipation W A combination of components Component Location Comments OTE A ROTECTIVE IMEDACE shall not be a single electronic device that employs electron conduction in a vacuum, gas or semiconductor TABLE: Current- or voltage-limiting device Component Location Measured Rated Verdict Comments Working voltage V Current A Working voltage V Current A TRF o. IEC61010_1F

49 Report o. S age 48 of 77 IEC Clause Requirement Test Result Remark Verdict 6.7 TABLE: CLEARACES and CREEAGE distances Form A ECLOSURES and protective barriers 8 Mechanical resistance to shock and impact Impedance Overcurrent protection basic insulation between MAIS parts rotective impedance Integrity of CLEARACES and CREEAGE distances Current- or voltage-limiting device Locatio n (see Form A.5) Enclosur e and live parts Measured (initial 6.7) CREEAGE CLEARA DISTACE CE Verdi ct Applied force mm mm Static (8.2.1) Mechanical tests (note) Rigidity (8.2) Impact (8.2.2) Drop (8.3) Test at max. RATED ambient Measured after test (if required) CREEAGE DISTACE CLEARACE ormal Handheld/ (10.5.1) mm mm (8.3.1) lugin Verdict >12 > C >12 >12 RI Comm ents OTE Refer to Form A.14 for dielectric strength tests following the above tests. TRF o. IEC61010_1F

50 Report o. S age 49 of 77 IEC Clause Requirement Test Result Remark Verdict 6.8 TABLE: Dielectric strength tests Form A b) Conformity after application of SIGLE FAULT CODITIOS rimary means of protection Connections to external circuits 6.7. Insulation requirements 2 (see Annex K) Fitting of non-detachable MAIS supply cords a) 2) Eliminating or reducing the sources of ignition within the equipment 9.4 c) Limited-energy circuit Overcurrent protection basic insulation between MAIS - parts 1 Record the fault, test or treatment applied before the dielectric strength test. 2 Humidity preconditioning required. Test site altitude... : ormal Test voltage correction factor (see Table 10)...: il Location or references from Forms A.2 and A.5 V to COM Live part and plastic enclosure Clause or sub-clause b), 6.4, 6.7, b), 6.4, 6.7, Humidity Yes/o Working voltage V Test voltage r.m.s./peak/d.cv Comments Verdict Yes 600V rms 2210 V rms BI Yes 600V rms 3510 V rms RI TABLE: Cord anchorage Form A.15 Location Mass kg ull Verdict Torque m Verdict Comment Dielectric strength test for 1 min. ( )...: V r.m.s. TRF o. IEC61010_1F

51 Report o. S age 50 of 77 Claus e IEC Requirement Test Result Remark Verdict 7. TABLE: rotection against mechanical HAZARDS Form A Limitation of force and pressure Gap limitations between moving parts art / Location Enclos ure Clause Clause Clause Continuous Temporary Minimum gaps (mm) Maximum gaps (mm) Contact présure max. 50 max. 150 max. 50 max. 150 max. 250 / 3 max. 0,75 s max. 250 / 3 max. 0,75 s Torso 500 Head 300 Leg Foot Toes Arm 120 Hand 100 Finger 25 Head 120 Foot 35 Finger Verdi ct Comments 9 TABLE: rotection against the spread of fire Form A.17 Item Source of HAZARD or area of the equipment considered (circuit, component, liquid etc.) 1 Testing in single fault condition (see form A.2 and form A.32) rotection Method (9a, 9b or 9c) 9a rotection details Tested in appliance, no fire, no hazards. 2 lastic enclosure and CB 9c Comply with Cl Verdict TRF o. IEC61010_1F

52 Report o. S age 51 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Constructional requirements Form A rinted circuit boards CB approved Material tested... : Generic name... : Material manufacturer...: Type...: Colour...: Conditioning details...: Sample 1 Sample 2 Sample 3 Thickness of specimen Duration of flaming after first Application Duration of flaming plus glowing After second application Specimen burns to holding clamp Cotton ignited Sample result mm s s Yes/o Yes/o ass/fail TRF o. IEC61010_1F

53 Report o. S age 52 of 77 IEC Clause Requirement Test Result Remark Verdict 9.4 TABLE: Limited-energy circuit Form A.19 Item 9.4 a) 9.4 b) Current and power limitation or Location (see Form A.17) Maximum potential in circuit voltage r.m.s./d.c. V Maximum available current A Maximum available power VA Overload protection after 120 s A 9.4 c) Decision Circuit separation Yes/o Comments battery supplied and is considered limited energy circuit TRF o. IEC61010_1F

54 Report o. S age 53 of 77 IEC Clause Requirement Test Result Remark Verdict 9.5 TABLE: Requirements for equipment containing or using flammable liquids Type of liquid 9.5 Flammable liquids Verdict b) Quantity c) Containment TRF o. IEC61010_1F

55 Report o. S age 54 of 77 IEC Clause Requirement Test Result Remark Verdict 10. TABLE : Temperature Measurements Form A.21A 10.1 Surface temperature limits - ORMAL CODITIO and / or SIGLE FAULT CODITIO 10.2 Temperature of windings- ORMAL CODITIO and / or SIGLE FAULT CODITIO 10.3 Other temperature measurements Operating conditions: ormal operation. Frequency... : -- Hz Test room ambient temperature (ta)... : 24.6 C Voltage...: -- V Test duration... : 2 h 02 min art / Location tm C tc C tmax C Verdict CB Enclosure of plug Ambient Ref. Ref. Comments OTE 1 - tm = measured temperature tc = tm corrected (tm ta+ 40 C or max. RATED ambient) tmax = maximum permitted temperature OTE 2 - see also 14.1 with reference to component operating conditions OTE 3 - Record values for ORMAL CODITIO and / or SIGLE FAULT CODITIO in this Form use additional form if necessary OTE 4 - see Form A.21B for details of winding temperature measurements TRF o. IEC61010_1F

56 Report o. S age 55 of 77 IEC Clause Requirement Test Result Remark Verdict 10.2 TABLE: Temperature of windings Resistance method Temperature Measurements MAIS transformers Motor temperatures Operating conditions...: Form A.21B Frequency... : Hz Test room ambient temperature (ta1/ta2)... : / C (initial / final) Voltage...: V Test duration...: h min art / Designation Rcold Rwarm Current A tr K tc C tmax C Verdict Comments OTE 1- Rcold = initial resistance Rwarm = final resistance tr = temperature rise tc = tr corrected (tc= tr - { ta2 - ta1} + [40 C or max RATED ambient]) tmax = maximum permitted temperature OTE 2 - Indicate insulation class (IEC 60085) under comments (optional) OTE 3 - Record values for ORMAL CODITIO and / or SIGLE FAULT CODITIO in this Form use additional form if necessary TABLE: Resistance to heat of non-metallic ECLOSURES Form A.22 Test method used... : on operative treatment... : [ ] Empty ECLOSURE...: [ ] Operative treatment...: [ ] Temperature during tests... : 70.0 ECLOSURE samples tested were...: Description Material Comments Verdict enclosure ABS o damage Dielectric strength test (6.8) : 3510 V r.m.s./peak/d.c. OTE Within 10 minutes of the end of treatment suitable tests in acc. to 8.2 and 8.3 must be conducted and pass criteria of 8.1. TRF o. IEC61010_1F

57 Report o. S age 56 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Insulating Materials Form A ) Ballpressure test Max. allowed impression diameter...: 2 mm art Test temperature C Impression Diameter (mm) Verdict Enclosure CB ) Vicat softening test (ISO 306) art Vicat softening temperature C Thickness of sample (mm) Verdict TRF o. IEC61010_1F

58 Report o. S age 57 of 77 IEC Clause Requirement Test Result Remark Verdict 8 TABLE: Mechanical resistance to shock and impact Form A rotection against HAZARDS from fluids Voltage tests can be carried out once after performing the tests of clause 8 and clause 11. However, if voltage tests are carried out separately after each set of tests, two forms can be used. Clause 8 tests Clause 11 tests Location (see form A.5) Static (8.2.1) 30 Impac t (8.2.2) orm al (8.3.1 ) Handh eld lugin Cleani ng (11.2) Spilla ge (11.3) Overflo w (11.4) IEC (11.6) Workin g voltage V Test voltage V Verdict Comments Enclosur e and live parts V 3510 Vrms fues Vrms RI BI OTE Use r.m.s., d.c. or peak to indicate the used test voltage. TRF o. IEC61010_1E

59 Report o. S age 58 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Leakage and rupture at high pressure Form A.25 art Maximum permissible working pressure Mpa Test pressure Ma Leakage Yes / o Deformation Yes / o Burst Yes / o Comments OTE see also Annex G with requirements for USA and Canada Leakage from low-pressure parts art Test pressure Mpa Leakage Yes / o Comments TRF o. IEC61010_1F

60 Report o. S age 59 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Ionizing radiation Form A Equipment intended to emit radiation Locations tested Measured values µsv/h Verdict Comments Equipment not intended to emit radiation Max. allowed effective dose rate at 100 mm : 1 µsv/h Locations tested Measured values µsv/h Verdict Comments TRF o. IEC61010_1F

61 Report o. S age 60 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Sound level Form A.27 a) b) c) d) e) f) Locations tested At operator s normal position and at bystanders positions Measured values dba Calculated maximum sound pressure level Ultrasonic pressure Locations tested Measured values Comments At operator s normal position At 1 m from the ECLOSURE a) b) c) d) db khz e) OTE o limit is specified at present, but a limit of 110 db above the reference pressure value of 20 a is under consideration for applicable frequencies between 20 khz and 100 khz. TRF o. IEC61010_1F

62 Report o. S age 61 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Batteries Form A.28 Battery load and charging circuit diagram: Battery type...: 6F22 battery Battery manufacturer/model/catalogue o...: -- Battery ratings... : 1 6.0V Reverse polarity instalment test o hazard Single component failures Verdict Component Open circuit Short circuit Battery TRF o. IEC61010_1F

63 Report o. S age 62 of 77 IEC Clause Requirement Test Result Remark Verdict 14.3 TABLE: Overtemperature protection devices Form A.29 Component Type (OTE) Reliability test Verdict Comments OTE: SR = non-self-resetting (10 times) R = non-resetting (1 time) SR = self-resetting (200 times) TRF o. IEC61010_1F

64 Report o. S age 63 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: MAIS transformer Form A Short circuit 14.6 MAIS transformers tested outside equipment Type...: Manufacturer... : Test in equipment Test on bench Test repeated inside equipment (see 14.6) Optional Insulation class (IEC 60085) of the lowest rated winding : Winding identification Type of rotector for winding (ote 1) Elapsed time Current, A primary secondary Winding temperature, C primary (see ote 2) secondary Tissue paper / cheesecloth OK? (ass / Fail) Voltage tests (see ote 3) rimary to secondary V rimary to core V Secondary to secondary V Secondary to core V Verdict ote 1: rimary fuse - F / ( ) A Secondary fuse - SF / ( ) A Overtemperature protection - O / ( ) C Impedance protection - Z ote 2: Indicate method of measurement TC = with thermocouple R = resistance method If resistance method is used, record resistance in cold and warm condition in FormA.20B! ote 3: Record the voltage applied and the type of voltage (r.m.s. / d.c. / peak) and for results use B = no breakdown or B = breakdown TRF o. IEC61010_1F

65 Report o. S age 64 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: MAIS transformer Form A Overload tests (for MAIS transformers) 14.6 MAIS transformers tested outside equipment Type...: Manufacturer... : Test in equipment Test on bench Test repeated inside equipment (see 14.6) Optional Insulation class (IEC 60085) of the lowest rated winding : Winding identification Type of rotector for winding (ote 1) Elapsed time Current, A primary secondary Winding temperature, C primary (see ote 2) secondary Tissue paper / cheesecloth OK? (ass / Fail) Voltage tests (see ote 3) rimary to secondary V rimary to core V Secondary to secondary V Secondary to core V Verdict ote 1: rimary fuse - F / ( ) A Secondary fuse - SF / ( ) A Overtemperature protection - O / ( ) C Impedance protection - Z ote 2: Indicate method of measurement TC = with thermocouple R = resistance method If resistance method is used, record resistance in cold and warm condition in FormA.20B! ote 3: Record the voltage applied and the type of voltage (r.m.s. / d.c. / peak) and for results use B = no breakdown or B = breakdown TRF o. IEC61010_1F

66 Report o. S age 65 of 77 IEC Clause Requirement Test Result Remark Verdict 14.8 TABLE: Transient overvoltage limiting devices Form A.32 Component / Designation Overvoltage Category MAIS voltage V rms Test voltage V tm C tc C tmax C Rupture Yes / o Circuit breaker tripped Verdict Comments Test room ambient temperature.: C OTE - tm = measured temperature tc = tm corrected (tm ta+ 40 C or max. RATED tmax ambient) = maximum permitted temperature Conformity is checked by applying 5 positive and 5 negative impulses with the applicable impulse withstand voltage, spaced up to 1 min apart, from a hybrid impulse generator (see IEC ). TRF o. IEC61010_1E

67 Report o. S age 66 of 77 IEC Clause Requirement Test Result Remark Verdict Annex H Technical properties TABLE: Qualification of conformal coating for protection against pollution Addition to Form A.xx Manufacturer... : Type...: Meet requirements of ASI / UL 746E...: [yes / no] Manufacturer declaration of coating material.: [yes / no] Operating temperature of coating... : [ ] C Comparative tracking index (CTI)... : [ ] Insulation resistance... : [ Dielectric strength...: [ ] Ω UV resistance (if required)... : [yes / no] Flammability rating... : reparation of the test specimens [yes / no] conducted... Item Test conditioning arameter Td : Samples Verdic t 1 Scratch resistance 2 Cold Visual inspection 3 Dry heat 4 Rapid temp. change 5 Damp heat 6 Adhesion of coading Visual inspection 7 Humidity 8 Insulation resistance Visual inspection ] V h Comments OTE Td = Test duration time TRF o. IEC61010_1E

68 Report o. S age 67 of 77 IEC Clause Requirement Test Result Remark Verdict TABLE: Reliability of potted components Addition to Form A.14 Temperature Cycling Test Manufacturer...: Type... : Construction...: otting compound...: CREEAGE distances measured...: CLEARACES measured...: Thickness through insulation... : Adhesive test ass/fail...: Test temperature T C...: Cycles at U= AC 500 V Leakage current (500 V) ma umber of cycles Date 68 h / 125 C 1. Cycle from to 2. Cycle from to 3. Cycle from to 4. Cycle from to 5. Cycle from to 6. Cycle from to 7. Cycle from to 8. Cycle from to 9. Cycle from to 10. Cycle from to After Cycling Test : Humidity conditioning 1 h / 25 C 2 h / 0 C Requirements for dielectric strength (s. insulation diagram) Test voltage V r.m.s Verdict Basic insulation Additional insulation Reinforced insulation V r.m.s. V r.m.s. V r.m.s. 48 h 1 h / 25 C TRF o. IEC61010_1E

69 Report o. S age 68 of 77 IEC Clause Requirement Test Result Remark Verdict 6. TABLE: Working voltage of Switch Mode ower Supply Addition to Form A.5 Location / Measuring track Insulation (Form A.5) RMS voltage V eak voltage V Required cl mm Measured cl mm Required cp mm Measured cp mm Verdict Comments Input supply V voltage.: Hz TRF o. IEC61010_1F

70 Report o.: S age 69 of 77 Appendix 1 Equipment List o. Equipment Manufacturer Model o. Serial o. Calibration Calibration date due date SE001 Data Acquisition / Switch Unit Agilent 34970A MY SE002 Thermocouple wire OMEGA TT-K kxff SE003 Temp. & Humid. Chamber Gongwen GDS SE004 Oven Chamber Rongfeng 101A SE005 DC Electronic Load Arry 3711A A06BI SE006 DC Electronic Load Arry 3711A A06BI SE007 DC Electronic Load Arry 3711A A06BI SE008 DC Electronic Load Arry 3711A A06BH SE009 Oscilloscope Tektronix TDS3012B YT SE010 Digital ower Meter Qingzhi 8716C SE011 Digital ower Meter Qingzhi 8716C SE012 Ohm Meter Yang Zi YD SE013 Multi Meter Fluke 115C SE014 Desktop Multi Meter Fluke SE015 Desktop Multi Meter Fluke SE016 Desktop Multi Meter Fluke SE017 Grounding Bond Meter Yang Zhi YD2654B SE018 Leakage Current Meter EXTECH SE019 Insulation Resistance Tester Yang Zhi YD9820A 20A SE020 Hi-ot Tester Yang Zhi YD2650A SE021 Electronic Scale Balance BCSS-F SE022 ush-ull Scale Algol K SE023 Digital Caliper Yitu YT SE024 Electronic Thermo-Hygrometer S.H.Qixiang CTH-608 GC-WS SE025 Goniometer Wenzhou JZC-B SE026 Tumbling Barrel Zhilitong GT-1 G SE027 Audio Generator LWDQGS TAG SE028 oise Generator DF DF SE029 lug Torque Tester Zhilitong LJ-1 LJ SE030 Test robe 13 Zhilitong T13 D3L SE031 Test robe 41 Zhilitiong T41 D30L SE032 Finger ail robe Zhilitong F-1 D SE033 Test Finger robe B Zhilitong TF-B D12J SE034 Rigid Finger robe Zhilitong RF D SE035 Test robe Zhilitong D4L SE036 Test robe C Zhilitong T-C SE037 Test robe D Zhilitong T-D SE038 Test robe Zhilitong FG2C D12L SE039 Test hook Zhilitong TH-1 W8L180T SE040 Accessibility robe Zhilitong ZA-1 A SE041 UL Finger robe Zhilitong UL-01 D5L SE042 Steel Ball Zhilitong GQ-1 G SE043 Ball ressure Tester Sinna S SE044 Ball ressure Tester Sinna S SE045 Hammer Sinna S SE046 Torque Driver kanon 12LTDK 08G SE047 Glow Wire Test Set Sinna ZRS SE048 eedle Flame Test Set Sinna ZY SE049 Switching Mode DC ower Supply Manson SIM-9106 G SE050 Hardened steel pin Zhilitong SC30 R SE051 latform scale shanghai TGT SE052 Salt spary tester Jiahui JH SE053 Test rod Zhilitong TZ-14 D SE054 Vibration tester shengshiwei SW-TF SE055 Surge tester Ceprei 1065A 0503Y SE056 Digital ower Meter Qingzhi 8713B SE057 Dust chamber Gongwen SC TRF o. IEC61010_1F

71 Report o.: S age 70 of 77 Calibration Calibration o. Equipment Manufacturer Model o. Serial o. date due date SE058 Draught-proof enclosure Tengbo TB180 Q SE059 Hammer Zhilitong CJ-3 C SE060 Hammer Zhilitong CJ-3 C SE061 Hammer Zhilitong CJ-3 C SE062 Data Acquisition / Switch Unit Agilent 34970A US SE063 Leakage Current Tester Simpson SE064 Temp. & Humid. Chamber Weihuang WHTH SE065 Salt spary tester Henqiang KH-160 / SE066 Oscillating tube damsion DMS-E DS- E SE067 Spray nozzle Lihui LH SE068 Immersion tester kunshang IX7-1 SK2018M SE069 Test robe 18 Aodesaichuang AUTO-18 auto SE070 Test robe 19 Aodesaichuang AUTO-19 auto SE071 Data Acquisition / Switch Unit Agilent 34970A MY SE072 Data Acquisition / Switch Unit Agilent 34970A MY SE073 Digital ower Meter Yokogawa WT210 91K SE074 Desktop Multi Meter Agilent 34401A MY SE075 Desktop Multi Meter Agilent 34401A MY SE076 Hi-ot Tester ME I RUIKE RK2672D RK72D SE077 Switching Mode ower Supply ZHAOXI KX-6030D KX.S.JS SE078 Torque Driver Aigu 10DSK SE079 Magnifying glass German 10x SE080 Regulated ower Supply AC AFC-11010G F SE081 Air ressure Gauge Tianya 509 / SE082 Step Temperature Room Long An LA-ORT28 LA SE083 "GO Gauge for E27 Caps KIGO B SE084 "OT GO Gauge for E27 Caps KIGO A SE085 "GO Gauge for dimension "S1" of E27 Caps KIGO C SE086 Gauge for E27 Caps for testing contact making KIGO SE087 Gauge for E27 Caps for testing protection against accidental KIGO A contact during insertion SE088 Oscilloscope Tektronix TDS3012B C SE089 Single wing drop tester FEILIG FL8618 / SE090 Data Acquisition / Switch Unit Agilent 34970A MY SE091 Thermocouple wire OMEGA TT-J / SE092 Touch current tester Ceprei 410B 1207AG SE093 Cord oscillating tester Dongguan lixiong LX-1211 / SE094 Lampholder digital torsion meter Inventfine Instrument Co., CH Ltd. SE095 Straight steel pin KIGO SE095 / SE096 Digital Caliper Guanglu SF2000 C SE097 Digital Caliper Guanglu SF2000 C SE098 Timer URSU S-528 / SE099 Timer URSU S-528 / SE100 Switching Mode DC ower Supply GW ISTEK GS-1850D E SE101 Digital ower Meter EVERFIE F SE102 Digital ower Meter EVERFIE F9901 G100731CJ SE103 Tape line YAGGUAG YG-206 / SE104 Electronic Thermo-Hygrometer UYIGAO CTH-608 UA SE105 ressure Gauge ZHHY SE105 / TRF o. IEC61010_1F

72 Report o.: S age 71 of 77 o. Equipment Manufacturer Model o. Serial o. Calibration Calibration date due date SE106 "GO Gauge for E14 Caps GRT/china F SE107 "OT GO Gauge for E14 Caps GRT/china B SE108 "GO Gauge for dimension "S1" of E14 Caps GRT/china G SE109 Gauge for E14 Caps for testing contact making GRT/china Gauge for E14 Caps for testing SE110 protection against accidental GRT/china contact during insertion SE111 "GO and "OT GO Gauge for base GU10 KIGO Kingo SE112 "GO plug gauge for E12 lampholder GRT/china C SE113 "OT GO plug gauge for E12 lampholder GRT/china B SE114 "GO Gauge for E26 Caps GRT/china D SE115 "OT GO Gauge for E26 Caps GRT/china L SE116 "GO Gauge for E40 Caps AGUI TESTIG SE117 "OT GO Gauge for E40 Caps AGUI TESTIG D SE118 Gauge for E40 Caps for testing AGUI contact making TESTIG SE119 Gauge for E40 Caps for testing AGUI protection against accidental TESTIG contact during insertion SE120 "Go" gauge for bi-pin cap on finished lamps G13 KIGO Kingo SE121 "Go" gauge for bi-pin cap on finished lamps G5 KIGO A-3 Kingo SE122 Gauge for three-pin flat-pin plugs AS/ZS 3112 KIGO (10A) Fig A 10A Kingo SE123 Gauge for three-pin flat-pin plugs AS/ZS 3112 KIGO (15A) Fig A 15A Kingo SE124 Gauge for three-pin flat-pin plugs AS/ZS 3112 KIGO (20A) Fig A 20A Kingo SE125 Gauge for two-pin flat-pin plugs AS/ZS 3112 KIGO with parallel pins Fig B Kingo SE126 SE127 Gauge for flat and round pin plugs (two flat live pins and a round earth pin) Gauge for flat and round pin plugs (two round live pins and a flat earth pin) Transport type simulation vibration tester TRF o. IEC61010_1F KIGO KIGO AS/ZS 3112 Fig F-A AS/ZS 3112 Fig F-B Kingo Kingo SE128 KIG DESIG KD C LT0CLA SE129 Oven Chamber Rongfeng 101A SE130 "Go" gauges for caps on finished AGUI lamps B22 TESTIG SE131 "ot Go" gauges for caps on AGUI finished lamps B22 TESTIG SE132 Gauges for testing the insertion AGUI of caps in lampholders B22d TESTIG A SE133 Gauges for testing the retention AGUI of B22d caps in the holder TESTIG B SE :1 Oscillograph robe intek HV-18HF SE :1 Oscillograph robe intek C-3308R / SE136 AC power source All power AW SE137 Horizonal&vertical tester AUTOSTROG AUTO-SA AUTO SE138 Tracking index tester AUTOSTROG AUTO-LDA AUTO SE139 Vicat softening tester AUTOSTROG AUTO-WK / SE140 Electroplated coating thickness tester Guangzhou Dongru electronic DR SE141 Battery Tester DG W602 DG2014W SE142 Test plug for antenna coaxial AGUI AG- /

73 Report o.: S age 72 of 77 o. TRF o. IEC61010_1F Equipment Manufacturer Model o. Serial o. Calibration date Calibration due date sockets TESTIG IEC60065F9 SE143 SHORE D Durometer Handpi LX-D SE144 Steel Ball AGUI TESTIG GQ-2 / SE145 "Go" gauges for caps on finished AGUI lamps B15 TESTIG SE146 "ot Go" gauges for caps on AGUI finished lamps B15 TESTIG SE147 Gauges for testing the insertion AGUI of caps in lampholders B15d TESTIG A SE148 Gauges for testing the retention AGUI of B15d caps in the holder TESTIG B SE149 "GO Gauge for E39 Caps AGUI TESTIG B SE150 Gauge for E39 Caps for testing AGUI contact making TESTIG A SE151 "OT GO Gauge for E39 Caps AGUI TESTIG C SE152 oise Generator/filter ZCTEK ZC6221 ZC SE153 Hi-ot Tester ME I RUIKE RK2671C RK71C-BEAI SE154 Data Acquisition / Switch Unit Agilent 34970A MY SE155 VC componds pressure tester AGUI at high temperature TESTIG AG8113F1 / SE156 Low ressure Tester BELL BE-ZK SE157 Thermal abuse chamber BELL BE B SE158 Temperature control short-circuit tester BELL BE-1000W SE159 rojectile Tester BELL BE SE160 Test machine for forced internal short circuit of cells BELL BE-6045W SE161 Crush tester BELL BE T SE162 Rapid temperature test chamber BELL BTKS-408C SE163 Mechanical shock(crash hazard) BELL BE SE164 Battery Testing System EWARE CT V10A-204 T SE165 Battery Testing System EWARE CT V10A-204 T SE166 Battery Testing System EWARE CT V6A-A T SE167 Shock tester LABTOE HSKT10 L SE168 Electromagnetic vibration tester LABTOE CV-700 L SE169 Electronic scales JM JM-A / SE170 Digital ower Meter EVERFIE F9901 G100731CO SE171 "GO and "OT GO Gauge for IEC Fig KIGO starters 6 / SE172 "OT GO Gauge for starters KIGO IEC Fig 7 / SE173 "GO Gauge for starters KIGO IEC Fig 8 / SE174 Internal resistance tester Testad BTS-100 IR SE175 DC Electronic Load RODIGIT 3302C 80602C SE176 DC Electronic Load RODIGIT 3302C SE177 Data Acquisition / Switch Unit Agilent 34970A MY SE178 Data Acquisition / Switch Unit Agilent 34970A US SE :1 Oscillograph robe intek C-3308R / SE180 Digital ower Meter EVERFIE F9901 G100731C SE181 Cord oscillating tester Futexing FT-CWT03 CWT SE182 ointer type DC current meter Shanghai Liangbiao C31-A SE183 Three phase ammeter Chengdu Huayi MH8161-9K SE184 Shunt pulianchuang FL-2/0.5 50A / SE185 Shunt pulianchuang FL-2/ A / SE186 Creepage distance testing card- Straight card AGUI TESTIG SE-A141 /

74 Report o.: S age 73 of 77 o. Equipment Manufacturer Model o. Serial o. Calibration Calibration date due date SE187 Creepage distance testing card- AGUI SE-A142 / Bending card TESTIG SE188 Conductivity Meters leici DDS-11A SE189 Manual Supercharger Zhejiang Yuhuang SB-10Mpa / SE190 Grounding resistance meter hangzhoudongs hun ZC29B-2 / SE191 AC power source All power AFW-210A SE192 Digital ower Meter EVERFIE F9901 G135716CM SE193 High Accuracy Array Spectrora EVERFIE HAAS-2000-IR1 M112279CM SE194 UV-VIS-IR Spectroradiometer G107114CJ13411 for hotobiological Safety EVERFIE MS Analysis SE195 Band Radiometer EVERFIE RD-2000F G114280CM SE196 upil Imaging Radiance Meter EVERFIE CX-2K G132536CF SE197 Digital ower Meter EVERFIE F9811 G135717CJ SE198 Digital CC&CV DC ower Supply EVERFIE WY3010 G111418CM SE199 AC ower Source EVERFIE DS1005 G119890CJ SE200 Spectral irradiance standard G100284CA1361 EVERFIE D204BH lamp SE201 Standard luminance source EVERFIE SLS-150 G137329CJ SE202 Standard lamp of ultraviolet G110132CA1361 EVERFIE SIS-631 radiation SE203 Falling water drops device Gongwen DJ-B / SE204 Continuous immersion in water device Gongwen X SE205 Torque Driver kanon 30LTDK / SE206 Gauge for single-phase two-pole AGUI plug TESTIG AGGB02F6 / SE207 "GO and "ot Go" Gauge for AGUI plug pins TESTIG AGEF1GO / SE208 Gauge for pin diameter AGUI TESTIG AGEF2 / SE209 Gauge for checking impossibility of single-pole insertion of into socket-outlets AGUI TESTIG AGEF4 / SE210 Gauge for plug pins AGUI TESTIG AGBS1363F5 / SE mm steel ball AGUI TESTIG ST-12.5 / SE212 Electronic Thermo-Hygrometer Boyang HTC-1 SE SE213 Electronic Thermo-Hygrometer Boyang HTC-1 SE SE214 Electronic Thermo-Hygrometer Boyang HTC-1 SE SE215 Electronic Thermo-Hygrometer Boyang HTC-1 SE SE216 Electronic Thermo-Hygrometer Boyang HTC-1 SE SE217 Electronic Thermo-Hygrometer Boyang HTC-1 SE SE218 Visual IR Thermometer FLUKE VT04 VT TRF o. IEC61010_1F

75 Report o. S age 74 of 77 Appendix 2 hoto documentation hoto 1 View: overview [ ] front [ ] rear [ ] right side [ ] left side [ ] top [ ] bottom [ ] internal hoto 2 View: [ ] front [ ] rear [ ] right side [ ] left side [ ] top [ ] bottom [ ] internal TRF o. IEC61010_1F TRF originator: VDE

76 Report o. S age 75 of 77 hoto documentation hoto 3 View: [ ] front [ ] rear [ ] right side [ ] left side [ ] top [ ] bottom [ ] internal hoto 4 View: [ ] front [ ] rear [ ] right side [ ] left side [ ] top [ ] bottom [ ] internal TRF o. IEC61010_1F TRF originator: VDE

77 Report o. S age 76 of 77 hoto documentation hoto 5 View: [ ] front [ ] rear [ ] right side [ ] left side [ ] top [ ] bottom [ ] internal hoto 6 View: [ ] front [ ] rear [ ] right side [ ] left side [ ] top [ ] bottom [ ] internal TRF o. IEC61010_1F TRF originator: VDE

78 Report o. S age 77 of 77 hoto documentation hoto 7 View: [ ] front [ ] rear [ ] right side [ ] left side [ ] CB top [ ] bottom [ ] internal hoto 8 View: [ ] front [ ] rear [ ] right side [ ] left side [ ] top [ ]CB bottom [ ] internal TRF o. IEC61010_1F ---End of report--- TRF originator: VDE

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information

LVD TEST REPORT. On Behalf of ZHANGZHOU WEIHUA ELECTRONIC CO., LTD. DIGITAL MULTIMETER. Models: DT9201A,DT9205A,DT9208A

LVD TEST REPORT. On Behalf of ZHANGZHOU WEIHUA ELECTRONIC CO., LTD. DIGITAL MULTIMETER. Models: DT9201A,DT9205A,DT9208A Reference o.: ET10113218-LVD LVD TEST REORT On Behalf of ZHAGZHOU WEIHUA ELECTROIC CO., LTD. DIGITAL MULTIMETER Models: DT9201A,DT9205A,DT9208A repared for : ZHAGZHOU WEIHUA ELECTROIC CO., LTD. O.3 JIMA

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

Page 1 of 4 Report Reference No. CPSZ IEC /EN Clause Requirement + Test Result Remark Verdict

Page 1 of 4 Report Reference No. CPSZ IEC /EN Clause Requirement + Test Result Remark Verdict age 1 of 4 Report Reference No. CSZ0928781 Report Reference No... : Tested by (name and signature)... : Approved by (name and signature).. : TEST REORT IEC 61010-1/ EN 61010-1 Safety requirements for electrical

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

National Standard. of the People s Republic of China

National Standard. of the People s Republic of China Translated English of Chinese Standard: GB4793.1-2007 www.chinesestandard.net Sales@ChineseStandard.net ICS 19.080; 71.040.10 L 09 National Standard GB of the People s Republic of China GB 4793.1-2007

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

Intertek Testing Service Taiwan Ltd. 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan as above Recom Development & Trading GmbH & Co KG

Intertek Testing Service Taiwan Ltd. 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan as above Recom Development & Trading GmbH & Co KG age 1 of 38 Report No.ETS-060067 TEST REORT IEC 60601-1 / EN 60601-1 Medical electrical equipment art 1: General requirements for safety Report reference No.... : ETS-060067 Testled by (+ signature)...

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

Copy of marking plate. Page 2 of 50 Report No. TRS

Copy of marking plate. Page 2 of 50 Report No. TRS Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :

More information

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has

More information

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances - age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro

More information

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

Remark: Whether parts of tests for the product have been subcontracted to other labs:

Remark: Whether parts of tests for the product have been subcontracted to other labs: Reference o.: WTS16S1166817S age 2 of 60 Test item description...: Trademark...: Model and/or type reference...: AU-BD350VA Rating(s)... : 220-240V~, 50Hz, Max. 350VA, Min 10VA Remark: Whether parts of

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

ES5 Security Theory/Regulations Answer Schedule

ES5 Security Theory/Regulations Answer Schedule ES5 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct

More information

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical

More information

Part 1: General requirements for basic safety and essential performance

Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REORT art 1: General requirements for basic safety and essential performance Report Number.... : 130501061SHA-001 Date of issue... : 2013-07-01 Total

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL 72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82 age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang

More information

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL 72-7570 DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL Table of Contents Specification 1 Safety 3 EMC 4 Installation 5 Connections 5 Operation 6 Maintenance 8 Specification General specifications

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

362 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual 362 Clamp Meter Users Manual PN 3622678 August 2010, Rev. 1, 4/13 2010, 2013 Fluke Corporation. All rights reserved. Printed in China. Specifications are subject to change without notice. All product names

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

FINAL-ER 42 Electrician Regulations Answer Schedule

FINAL-ER 42 Electrician Regulations Answer Schedule FINAL-ER 42 Electrician Regulations Answer Schedule Notes:1. (1 mark) means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions.

More information

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A Ratings...: age 2 of 41 Report o.: CTL1607012503-WS Adapter: Input: 100-240Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A age 3 of 41 Report o.: CTL1607012503-WS Summary of testing: Testing

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

DC POWER SUPPLY ALIMENTATION C.C.

DC POWER SUPPLY ALIMENTATION C.C. DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify

More information

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements

TEST REPORT IEC Audio, video and similar electronic apparatus - Safety requirements Test Report issued under the responsibility of www.nemko.com TEST REORT IEC 60065 Audio, video and similar electronic apparatus - Safety requirements Report Reference o.... : 125414 Date of issue... :

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Electrical test equipment for use on low voltage electrical systems

Electrical test equipment for use on low voltage electrical systems Electrical test equipment for use on low voltage electrical systems Guidance Note GS38 (Fourth edition) This general series guidance note is aimed at people (including electricians, electrical contractors,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT) Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB13035196 Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR

More information

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 70.410.14.127.01-01 Date of issue... : 2014-07-03 Total number of pages... 61

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of SHENZHEN MUST POWER LIMITED. Inverter

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of SHENZHEN MUST POWER LIMITED. Inverter SHEZHE EMTEK CO., LTD. REORT O.: ES101214114S ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of SHEZHE MUST OWER LIMITED Inverter Model(s): E302048E-2000W, E303048E-3000W, E304048E-4000W, E305048E-5000W,

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES MINISTRY OF LABOUR, INDUSTRIAL RELATIONS AND EMPLOYMENT GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES Occupational Safety & Health Inspectorate These guidelines should be used with approved standards:

More information

Page 3 of 32 Report No Summary of testing:

Page 3 of 32 Report No Summary of testing: age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:

More information

Page 2 of 39 Report No. CTI PA Testing location:

Page 2 of 39 Report No. CTI PA Testing location: age 2 of 39 Report No. CTI A 2841-2 Tests performed (name of test and test clause): according to :2009: 5 - Interface characteristics, 6 Information, 7 - Service conditions, 10.2.3.3 - Verification of

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual MY-65 4 1/2-DIGIT DIGITAL MULTIMETER Users Manual Read the Users Manual thoroughly before use. WARRANTY This instrument is warranted to be free from defects in material and workmanship for a period of

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings 1587 FC/1587/1577 Insulation Multimeter Safety Information Go to www.fluke.com to register your Product and find more information. A Warning identifies conditions and procedures that are dangerous to the

More information

E/ECE/324/Rev.2/Add.104/Rev.2 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2

E/ECE/324/Rev.2/Add.104/Rev.2 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2 28 September 2011 Agreement Concerning the adoption of uniform technical prescriptions for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles and the conditions

More information

SHA-001 Date of issue...: Total number of pages Report Reference No...:

SHA-001 Date of issue...: Total number of pages Report Reference No...: TEST REORT lugs and socket-outlets for household and similar purposes art 2-1: General requirements on plugs and portable socket-outlets Report Reference No....: 130600884SHA-001 Date of issue...: 2013-07-09

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

Report No.: STR S. ST/SG/AC.10/11 Rev.5/Amend.2 Section 38.3

Report No.: STR S. ST/SG/AC.10/11 Rev.5/Amend.2 Section 38.3 TEST REORT ST/SG/AC.10/11 Rev.5/Amend.2 Section 38.3 AMENDMENTS TO THE FIFTH REVISED EDITION OF THE RECOMMENDATIONS ON THE TRANSORT OF DANGEROUS GOODS, MANUAL OF TEST AND CRITERIA (Section 38.3: Lithium

More information

For. Shanghai Moons Automation Control Co., Ltd.

For. Shanghai Moons Automation Control Co., Ltd. Shenzhen BCTC Technology Co., Ltd. Report o.: BCTC-13080904S ALICATIO FOR LVD For Shanghai Moons Automation Control Co., Ltd. roduct ame: LED drivers Trademark: Model : repared For : MU096A024A, MU096A175AQD

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven

More information