TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Size: px
Start display at page:

Download "TEST REPORT IEC Information technology equipment Safety Part 1: General requirements"

Transcription

1 Test Report issued under the responsibility of: TEST REORT IEC Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E Date of issue... : Total number of pages Applicant s name... : Hon Hai recision Industry Co., Ltd. Address... : No.2, Zihyou St., Tucheng City, New Taipei City, 23680, Taiwan Test specification: Standard... : IEC :2005 (Second Edition) + Am 1: Am 2:2013 Test procedure... : CB Scheme Non-standard test method... : Test Report Form No.... : IEC60950_1F Test Report Form(s) Originator... : SGS Fimko Ltd Master TRF... : Dated Copyright 2014 IEC System of Conformity Assessment Schemes for Electrotechnical Equipment and Components (IECEE System). All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. General disclaimer: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing CB Testing Laboratory. The authenticity of this Test Report and its contents can be verified by contacting the NCB, responsible for this Test Report.

2 age 2 of 94 Report No.: CB170707E Test item description...: Instant rint Digital Camera Trade Mark... : olaroid Manufacturer...: CHAM TECH OTICAL (FOSHAN) CORORATION Model/Type reference...: O Ratings...: 5Vdc, 2A Testing CB Laboratory: Bureau Veritas Consumer roduct Services Limited, Taoyuan Branch Testing location/ address... : No. 19, Hwa Ya 2 nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Chinese Taipei Associated Testing Laboratory: Testing location/ address... : Tested by (name + signature)... : Bill Lin / Senior Engineer Approved by (name + signature)... : Danny Lin / Technical Manager Testing procedure: TM/CTF Stage 1: Testing location/ address... : Tested by (name + signature)... : Approved by (name + signature)... : Testing procedure: WMT/CTF Stage 2: Testing location/ address... : Tested by (name + signature)... : Approved by (name + signature)... : Testing procedure: SMT/CTF Stage 3 or 4: Tested by (name + signature)... : Witnessed by (name + signature)... : Approved by (name + signature)... : Supervised by (name + signature)... :

3 age 3 of 94 Report No.: CB170707E List of Attachments (including a total number of pages in each attachment): Summary of testing: Tests performed (name of test and test clause): Input Test Durability of Marking Test Limited ower Source Measurements , Drop Test , Stress Relief Test Sharp Edge Test Battery Overcharge/Discharge and Lithium Battery Reverse Current Measurement Tests Heating (Temperature) Test Abnormal and Fault Condition Tests Testing location: Bureau Veritas Consumer roduct Services Limited, Taoyuan Branch No. 19, Hwa Ya 2nd Rd., Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Chinese Taipei The equipment under test (EUT) has been evaluated at maximum ambient (Tma) of +55C according to the roduct Specification. The equipment is equipped with the LED back-light anel. The Limited Current Circuit Test is not considered necessary. Unless otherwise specified, all tests were performed on ower Supply Adapter (SA) / Car adapter with output rating 5Vdc, 2A min. All tests were measured under the worst case and the load conditions used during testing are: - The EUT with the maximum brightness and volume. - The camera was operated and pinted photo continuously. - The EUT was continuously transmitting and downloading data via the wireless transmission link. - The battery pack is tested under charging and discharging condition according to the battery pack s specification in IEC and IEC test report. All functions were operating at the same time. Summary of compliance with National Differences: AT, AU, BE, CA, CH, CN, DE, DK, FI, FR, GB, HU, J, KR, NL, NO, SE, SG, SI, US The product fulfils the requirements of IEC :2005+A1:2009+A2:2013 and/or EN : 2006+A11:2009+A1:2010+A12:2011+A2:2013.

4 age 4 of 94 Report No.: CB170707E Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks.

5 Test item particulars... : age 5 of 94 Report No.: CB170707E Equipment mobility...: [ ] movable [X] hand-held [X] transportable for main unit [] stationary [] for building-in [] direct plug-in for external adapter Connection to the mains...: Operating condition...: Access location...: [] pluggable equipment [] type A for external adapter [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord [X] not directly connected to the mains [X] continuous [] rated operating / resting time: [X] operator accessible [] restricted access location Over voltage category (OVC)...: [] OVC I [] OVC II [] OVC III [] OVC IV [X] other: DC Supply Mains supply tolerance (%) or absolute mains supply values...: Tested for IT power systems...: [] Yes [X] No IT testing, phase-phase voltage (V)...: Class of equipment...: [] Class I [] Class II [X] Class III [] Not classified Considered current rating of protective device as part of the building installation (A)...: ollution degree (D)...: [] D 1 [X] D 2 [] D 3 I protection class...: IX0 Altitude during operation (m)...: Altitude of test laboratory (m)...: Mass of equipment (kg)...: ossible test case verdicts: Below 2000m Below 2000m 0.42kg - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Testing... : Date of receipt of test item... : Date (s) of performance of tests... : to General remarks: "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator.

6 age 6 of 94 Report No.: CB170707E Manufacturer s Declaration per sub-clause of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided... : Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : CHAM TECH OTICAL (FOSHAN) CORORATION General product information: No.35, North Huabao Road, Chengxi Development Zone Foshan, China 1. The equipment is a class III Instant rint Digital Camera which is intended to be used with information technology equipment covered by the scope of this standard. 2. For acceptance of the accessory ower Supply Adapter (SA) output shall comply with LS requirements, output rating (5Vdc, 2A min.), and maximum temperature 55 C. SA have to be evaluated according to IEC :2005+A1:2009+A2:2013 and where applicable, according to national differences of countries where they are used e.g.: for international approval procedures. 3. hysical Size: approx.142mm (L) x 120mm (W) x 33mm (H). Test condition: Temperature: 25C Relative humidity: 60% Air pressure: 950 mbar The test sample was a pre-production sample without serial number. Abbreviations used in the report: - normal conditions N.C. - single fault conditions S.F.C - functional insulation O - basic insulation BI - double insulation DI - supplementary insulation SI - between parts of opposite polarity BO - reinforced insulation RI Indicate used abbreviations (if any)

7 age 7 of 94 Report No.: CB170707E IEC GENERAL 1.5 Components General Components, which were found to affect safety aspects, are conformed to the relevant IEC component standards and/or comply with the requirements of this standard. Comply with IEC or relevant component standard (See appended table 1.5.1) Evaluation and testing of components Components which are certified to IEC and/or national standards are used correctly within their ratings. Components not covered by IEC standards are tested under the conditions presented in the equipment Thermal controls No thermal controls used Transformers Class III equipment, supplied by SELV Interconnecting cables Interconnecting cable for Interconnection is carrying only SELV voltages on an energy level below 240 VA Capacitors bridging insulation Class III equipment, supplied by SELV Resistors bridging insulation Class III equipment, supplied by SELV Resistors bridging functional, basic or supplementary insulation Resistors bridging double or reinforced insulation between a.c. mains and other circuits Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable Class III equipment, supplied by SELV. Class III equipment, supplied by SELV. Class III equipment, supplied by SELV Components in equipment for IT power systems Class III equipment, supplied by SELV Surge suppressors Class III equipment, supplied by SELV General Class III equipment, supplied by SELV rotection of VDRs Class III equipment, supplied by SELV Bridging of functional insulation by a VDR Class III equipment, supplied by SELV.

8 age 8 of 94 Report No.: CB170707E IEC Bridging of basic insulation by a VDR Class III equipment, supplied by SELV Bridging of supplementary, double or reinforced insulation by a VDR Class III equipment, supplied by SELV. 1.6 ower interface AC power distribution systems Class III equipment, supplied by SELV Input current (See appended table 1.6.2) Voltage limit of hand-held equipment The equipment is hand-held equipment and the rated voltage did not exceed 250V Neutral conductor Class III equipment, supplied by SELV. 1.7 Marking and instructions ower rating and identification markings See below ower rating marking No direct connection to the mains Supply. Multiple mains supply connections...: No such construction. Rated voltage(s) or voltage range(s) (V)... : 5Vdc Symbol for nature of supply, for d.c. only... : Class III equipment, not directly connect to mains. Rated frequency or rated frequency range (Hz)... : The EUT is supplied by DC. Rated current (ma or A)... : 2A Identification markings See below. Manufacturer s name or trade-mark or identification mark... : Model identification or type reference... : O Trademark: olaroid Symbol for Class II equipment only... : Class III equipment, supplied by SELV. Other markings and symbols... : Additional symbols or markings do not give risk to misunderstanding. See copy of marking plate for detail Use of graphical symbols The meaning of the DC symbol marking is obvious. Other marking had been explained in the instruction Safety instructions and marking See below.

9 age 9 of 94 Report No.: CB170707E IEC General Safety related information in English has been evaluated. Manufacturer commits to provide them in the language of the countries where the product will be distributed Disconnect devices Class III equipment, supplied by SELV Overcurrent protective device No such device IT power distribution systems Class III equipment, supplied by SELV Operator access with a tool No tool is necessary to operate this product Ozone This EUT is not intended to produce the ozone Short duty cycles Equipment is designed for continuous operation Supply voltage adjustment... : No such device. Methods and means of adjustment; reference to installation instructions... : No such device ower outlets on the equipment... : No power outlets Fuse identification (marking, special fusing Class III equipment, supplied characteristics, cross-reference)...: by SELV Wiring terminals See below rotective earthing and bonding terminals...: Class III equipment, no protective earthing Terminals for a.c. mains supply conductors Class III equipment. Not to connect to a.c. mains directly Terminals for d.c. mains supply conductors The EUT is not intended to be connected to the d.c. mains Controls and indicators See below Identification, location and marking...: The function of indicators and controls is clearly identified Colours...: Colors are used and safety is not involved Symbols according to IEC : No safety relevant switch Markings using figures...: Not used Isolation of multiple power sources...: Not used Thermostats and other regulating devices...: No thermostat or other regulating devices Durability After this test there was no damage to the label. The marking on the label did not fade. There was no curling or lifting on the label edge.

10 age 10 of 94 Report No.: CB170707E IEC Removable parts No safety marking placed on removable parts Replaceable batteries... : No such components. Language(s)... : English Equipment for restricted access locations...: No for use in the restricted access location. 2 ROTECTION FROM HAZARDS 2.1 rotection from electric shock and energy hazards rotection in operator access areas See below Access to energized parts Class III equipment, supplied by SELV and no hazard voltage generated inside. Test by inspection... : Class III equipment, supplied by SELV and no hazard voltage generated inside. Test with test finger (Figure 2A)... : Class III equipment, supplied by SELV and no hazard voltage generated inside. Test with test pin (Figure 2B)... : Class III equipment, supplied by SELV and no hazard voltage generated inside. Test with test probe (Figure 2C)... : No TNV circuit in the equipment Battery compartments No such construction Access to ELV wiring No ELV wiring in operator accessible area. Working voltage (Vpeak or Vrms); minimum distance through insulation (mm) Access to hazardous voltage circuit wiring No hazardous voltage wiring in operator accessible area Energy hazards... : There is no energy hazard inside the EUT Manual controls No such device Discharge of capacitors in equipment Class III equipment, supplied by SELV. Measured voltage (V); time-constant (s)... : Energy hazards d.c. mains supply This product is not intended to be connected to d.c. mains supply. a) Capacitor connected to the d.c. mains supply.. : This product is not intended to be connected to d.c. mains supply.

11 age 11 of 94 Report No.: CB170707E IEC b) Internal battery connected to the d.c. mains supply : This product is not intended to be connected to d.c. mains supply Audio amplifiers... : See cl rotection in service access areas No maintenance works necessary in operation mode rotection in restricted access locations It is not intended to be used in restricted locations. 2.2 SELV circuits General requirements Class III equipment, supplied by SELV and there is no hazardous voltage inside the EUT Voltages under normal conditions (V)... : Class III equipment, supplied by SELV and there is no hazardous voltage inside the EUT Voltages under fault conditions (V)... : Class III equipment, supplied by SELV and there is no hazardous voltage inside the EUT Connection of SELV circuits to other circuits... : Only the connection to SELV. 2.3 TNV circuits Limits No TNV circuit Type of TNV circuits... : Separation from other circuits and from accessible parts No TNV circuit General requirements No TNV circuit rotection by basic insulation No TNV circuit rotection by earthing No TNV circuit rotection by other constructions... : No TNV circuit Separation from hazardous voltages No TNV circuit Insulation employed... : Connection of TNV circuits to other circuits No TNV circuit Insulation employed... : Test for operating voltages generated externally No TNV circuit 2.4 Limited current circuits General requirements The EUT was supplied by SELV. No limited current circuit inside it.

12 age 12 of 94 Report No.: CB170707E IEC Limit values The EUT was supplied by SELV. No limited current circuit inside it. Frequency (Hz)... : Measured current (ma)... : Measured voltage (V)... : Measured circuit capacitance (nf or µf)... : Connection of limited current circuits to other circuits The EUT was supplied by SELV. No limited current circuit inside it. 2.5 Limited power sources a) Inherently limited output The output of data port (Micro SD) was not intended to supply the power to other accessory. b) Impedance limited output Not selected. c) Regulating network or IC current limiter, limits output under normal operating and single fault condition Use of integrated circuit (IC) current limiters d) Overcurrent protective device limited output Max. output voltage (V), max. output current (A), max. apparent power (VA)... : Current rating of overcurrent protective device (A).: See appended table rovisions for earthing and bonding rotective earthing No protective earthing Functional earthing No functional earthing Use of symbol for functional earthing...: No functional earthing rotective earthing and protective bonding conductors No protective earthing General No protective earthing Size of protective earthing conductors No protective earthing Rated current (A), cross-sectional area (mm 2 ), AWG... : Size of protective bonding conductors No protective earthing Rated current (A), cross-sectional area (mm 2 ), AWG... : rotective current rating (A), cross-sectional area (mm 2 ), AWG... : Resistance of earthing conductors and their terminations; resistance (), voltage drop (V), test current (A), duration (min)... : No protective earthing

13 age 13 of 94 Report No.: CB170707E IEC Colour of insulation... : No protective earthing Terminals No protective earthing General No protective earthing rotective earthing and bonding terminals No protective earthing Rated current (A), type, nominal thread diameter (mm)... : Separation of the protective earthing conductor from protective bonding conductors No protective earthing Integrity of protective earthing No protective earthing Interconnection of equipment No protective earthing Components in protective earthing conductors and protective bonding conductors No protective earthing Disconnection of protective earth No protective earthing arts that can be removed by an operator No protective earthing arts removed during servicing No protective earthing Corrosion resistance No protective earthing Screws for protective bonding No protective earthing Reliance on telecommunication network or cable distribution system No protective earthing 2.7 Overcurrent and earth fault protection in primary circuits Basic requirements Class III equipment. Not connect to a.c. mains directly. Instructions when protection relies on building installation Class III equipment. Not connect to a.c. mains directly Faults not simulated in Class III equipment. Not connect to a.c. mains directly Short-circuit backup protection Class III equipment. Not connect to a.c. mains directly Number and location of protective devices... : Class III equipment. Not connect to a.c. mains directly rotection by several devices Class III equipment. Not connect to a.c. mains directly Warning to service personnel... : No service work is necessary. 2.8 Safety interlocks General principles No any hazards in the meaning of standard at operator access involves areas rotection requirements There is no safety interlock in the equipment.

14 age 14 of 94 Report No.: CB170707E IEC Inadvertent reactivation There is no safety interlock in the equipment Fail-safe operation There is no safety interlock in the equipment. rotection against extreme hazard There is no safety interlock in the equipment Moving parts There is no safety interlock in the equipment Overriding There is no safety interlock in the equipment Switches, relays and their related circuits There is no safety interlock in the equipment Separation distances for contact gaps and their related circuits (mm)... : There is no safety interlock in the equipment Overload test There is no safety interlock in the equipment Endurance test There is no safety interlock in the equipment Electric strength test There is no safety interlock in the equipment Mechanical actuators There is no safety interlock in the equipment. 2.9 Electrical insulation roperties of insulating materials Natural rubber, asbestos or hygroscopic materials are not used Humidity conditioning Class III equipment, no critical insulation in the EUT. Relative humidity (%), temperature ( C)... : Grade of insulation Only functional insulation Separation from hazardous voltages Class III equipment, no critical insulation in the EUT. Method(s) used... : 2.10 Clearances, creepage distances and distances through insulation General Class III equipment, supplied by SELV and no critical insulation inside EUT Frequency... : Class III equipment ollution degrees... : Class III equipment, supplied by SELV and no critical insulation inside EUT.

15 age 15 of 94 Report No.: CB170707E IEC Reduced values for functional insulation Considered in the Clause c) Intervening unconnected conductive parts Class III equipment, no critical insulation in the EUT Insulation with varying dimensions Class III equipment, no critical insulation in the EUT Special separation requirements Class III equipment, no critical insulation in the EUT Insulation in circuits generating starting pulses No such circuit in the equipment Determination of working voltage Class III equipment. Not connect to a.c. mains directly General Class III equipment. Not connect to a.c. mains directly RMS working voltage Class III equipment. Not connect to a.c. mains directly eak working voltage Class III equipment. Not connect to a.c. mains directly Clearances Class III equipment, no critical insulation in the EUT. Only the functional Insulation inside the EUT General See below Mains transient voltages Class III equipment. Not connect to a.c. mains directly. a) AC mains supply... : Class III equipment. Not connect to a.c. mains directly. b) Earthed d.c. mains supplies... : The equipment is not intended to be supplied by d.c. mains. c) Unearthed d.c. mains supplies... : The EUT is not intended to be supplied by d.c. mains. d) Battery operation... : No such construction Clearances in primary circuits Class III equipment, no critical insulation in the EUT Clearances in secondary circuits Class III equipment, no critical insulation in the EUT. Only the functional Insulation inside the EUT Clearances in circuits having starting pulses No such circuit Transients from a.c. mains supply... : Class III equipment. Not connect to a.c. mains directly Transients from d.c. mains supply... : The EUT is not intended to be connected to the d.c. mains.

16 age 16 of 94 Report No.: CB170707E IEC Transients from telecommunication networks and cable distribution systems... : No connection to the telecommunication network and cable distribution system Measurement of transient voltage levels Class III equipment. Not connect to mains directly. a) Transients from a mains supply Class III equipment. Not connect to mains directly. For an a.c. mains supply... : Class III equipment. Not connect to a.c. mains directly. For a d.c. mains supply... : Class III equipment. Not connect to d.c. mains directly. b) Transients from a telecommunication network : No such construction Creepage distances Class III equipment, no critical insulation in the EUT. Only the functional Insulation inside the EUT General Class III equipment, no critical insulation in the EUT. Only the functional Insulation inside the EUT Material group and comparative tracking index Class III equipment, no critical insulation in the EUT. Only the functional Insulation inside the EUT. CTI tests... : Minimum creepage distances Class III equipment, no critical insulation in the EUT. Only the functional Insulation inside the EUT Solid insulation No such construction General No such construction Distances through insulation No such construction Insulating compound as solid insulation No such construction Semiconductor devices No such construction Cemented joints No such construction Thin sheet material General No such construction Separable thin sheet material No such construction. Number of layers (pcs)... : Non-separable thin sheet material No such construction Thin sheet material standard test procedure No such construction. Electric strength test Thin sheet material alternative test procedure No such construction. Electric strength test

17 age 17 of 94 Report No.: CB170707E IEC Insulation in wound components No such construction Wire in wound components No such construction. Working voltage... : No such construction. a) Basic insulation not under stress... : No such construction. b) Basic, supplementary, reinforced insulation... : No such construction. c) Compliance with Annex U... : No such construction. Two wires in contact inside wound component; angle between 45 and : Wire with solvent-based enamel in wound components Electric strength test No such construction. No such construction. Routine test No such construction Additional insulation in wound components No such construction. Working voltage... : No such construction. - Basic insulation not under stress... : No such construction. - Supplementary, reinforced insulation... : No such construction Construction of printed boards See below Uncoated printed boards Class III equipment, no critical insulation in the EUT. Only the functional Insulation inside the EUT Coated printed boards No coated printed boards Insulation between conductors on the same inner surface of a printed board Insulation between conductors on different layers of a printed board No such construction. No such construction. Distance through insulation No such construction. Number of insulation layers (pcs)... : No such construction Component external terminations No such construction Tests on coated printed boards and coated components No such construction Sample preparation and preliminary inspection No such construction Thermal conditioning No such construction Electric strength test No such construction Abrasion resistance test No such construction Thermal cycling No such construction Test for ollution Degree 1 environment and insulating compound Tests for semiconductor devices and cemented joints No such construction. ollution degree 2 is considered. No such construction.

18 age 18 of 94 Report No.: CB170707E IEC Enclosed and sealed parts No hermetically sealed component. 3 WIRING, CONNECTIONS AND SULY 3.1 General Current rating and overcurrent protection Internal wiring gauge is suitable for current intended to be carried rotection against mechanical damage Wires do not touch sharp edges and heatsinks which could damage the insulation and cause hazard Securing of internal wiring The wires are secured by solder pins so that a loosening of the terminal connection is unlikely Insulation of conductors The insulation of the individual conductors is suitable for the application and the working voltage Beads and ceramic insulators Not used Screws for electrical contact pressure No screws of insulating material for electrical connections, it shall be evaluated in the end product Insulating materials in electrical connections No non-metallic materials in electrical connections Self-tapping and spaced thread screws No self tapping screws are used Termination of conductors All conductors are reliable secured. 10 N pull test 10 N pull tests performed for all relevant conductors. No hazards caused hereby Sleeving on wiring No sleeve was used. 3.2 Connection to a mains supply Means of connection See below Connection to an a.c. mains supply Class III equipment, not directly connect to mains Connection to a d.c. mains supply Class III equipment, not directly connect to mains Multiple supply connections Class III equipment, not directly connect to mains ermanently connected equipment Not a permanently connected equipment.

19 age 19 of 94 Report No.: CB170707E IEC Number of conductors, diameter of cable and conduits (mm)... : Appliance inlets Class III equipment; not directly connect to the mains ower supply cords Class III equipment; not directly connect to the mains AC power supply cords Class III equipment; not directly connect to the mains. Type... : Rated current (A), cross-sectional area (mm 2 ), AWG... : DC power supply cords Class III equipment, not directly connect to d.c. mains Cord anchorages and strain relief Class III equipment, not directly connect to mains. Mass of equipment (kg), pull (N)... : Longitudinal displacement (mm)... : rotection against mechanical damage Class III equipment; not directly connect to the mains Cord guards Class III equipment; not directly connect to the mains. Diameter or minor dimension D (mm); test mass (g)... : Radius of curvature of cord (mm)... : Supply wiring space Class III equipment; not directly connect to the mains. 3.3 Wiring terminals for connection of external conductors Wiring terminals Class III equipment; not directly connect to the mains Connection of non-detachable power supply cords Class III equipment; not directly connect to the mains Screw terminals Class III equipment; not directly connect to the mains Conductor sizes to be connected Class III equipment; not directly connect to the mains. Rated current (A), cord/cable type, cross-sectional area (mm 2 )... : Wiring terminal sizes Class III equipment; not directly connect to the mains. Rated current (A), type, nominal thread diameter (mm)... :

20 age 20 of 94 Report No.: CB170707E IEC Wiring terminal design Class III equipment; not directly connect to the mains Grouping of wiring terminals Class III equipment; not directly connect to the mains Stranded wire Class III equipment; not directly connect to the mains. 3.4 Disconnection from the mains supply General requirement Class III equipment; not directly connect to the mains Disconnect devices Class III equipment; not directly connect to the mains ermanently connected equipment The EUT is not permanently connected equipment arts which remain energized Class III equipment; not directly connect to the mains Switches in flexible cords No switch and no flexible cords provided Number of poles - single-phase and d.c. equipment Class III equipment; not directly connect to the mains Number of poles - three-phase equipment Class III equipment; not directly connect to the mains Switches as disconnect devices Class III equipment; not directly connect to the mains lugs as disconnect devices Class III equipment; not directly connect to the mains Interconnected equipment Class III equipment; not directly connect to the mains Multiple power sources Class III equipment; not directly connect to the mains. 3.5 Interconnection of equipment General requirements See below Types of interconnection circuits... : SELV circuits interconnected only to SELV circuit ELV circuits as interconnection circuits No ELV interconnection circuits Data ports for additional equipment Data ports (Micro SD) was not intended to supply the power to other accessory. 4 HYSICAL REQUIREMENTS 4.1 Stability

21 age 21 of 94 Report No.: CB170707E IEC Angle of 10 For the equipment, the mass is less than 7kg. Test force (N)... : Not floor-standing equipment. 4.2 Mechanical strength General See below. Rack-mounted equipment. No such construction Steady force test, 10 N No safety relevant damages after test Steady force test, 30 N No door or cover in the operator access area Steady force test, 250 N 250N applied to the internal battery. No safety relevant damages after test Impact test The EUT is transportable equipment. Fall test Swing test The EUT is transportable equipment. The EUT is transportable equipment Drop test; height (mm)... : The height of drop is 1m Stress relief test Tested to the internal battery, after 7 hours at 84.0 C and cooling down to room temperature, no shrinkage, distortion or loosening Cathode ray tubes No CRT inside the EUT. icture tube separately certified... : No CRT inside the EUT High pressure lamps No high pressure lamps Wall or ceiling mounted equipment; force (N)... : No such construction. 4.3 Design and construction Edges and corners Edges and corners of the enclosure are rounded Handles and manual controls; force (N)... : No such device Adjustable controls No such device Securing of parts Electrical and mechanical connections and parts expected to withstand usual mechanical stress Connection by plugs and sockets No mismatch of connectors, plugs or sockets possible Direct plug-in equipment No such construction. Torque... :

22 age 22 of 94 Report No.: CB170707E IEC Compliance with the relevant mains plug standard... : Heating elements in earthed equipment No heating element Batteries See below. - Overcharging of a rechargeable battery Battery pack is IEC and IEC certified, see append table Unintentional charging of a non-rechargeable battery No such component. - Reverse charging of a rechargeable battery Battery pack is used within their specified rating and no reverse polarity installation could be happened due to design of pack. - Excessive discharging rate for any battery Battery pack is IEC and IEC certified, see append table Oil and grease No oil and grease inside the equipment Dust, powders, liquids and gases The equipment is not intended to be exposed to dust, powers, liquids and gases Containers for liquids or gases No container for liquids or gases provided Flammable liquids... : No flammable liquids in the equipment. Quantity of liquid (l)... : Flash point (C)... : No flammable liquids in the equipment. No flammable liquids in the equipment Radiation See clause General No risk of harmful effects of radiation Ionizing radiation No ionizing radiation. Measured radiation (pa/kg)... : -- Measured high-voltage (kv)... : -- Measured focus voltage (kv)... : -- CRT markings... : Effect of ultraviolet (UV) radiation on materials No UV radiation. art, property, retention after test, flammability classification... : No UV radiation Human exposure to ultraviolet (UV) radiation... : No UV radiation Lasers (including laser diodes) and LEDs See below Lasers (including laser diodes) No such devices.

23 age 23 of 94 Report No.: CB170707E IEC Laser class... : Light emitting diodes (LEDs) The main unit with LED has been tested and evaluated according to IEC/EN 62471, see appended table Other types... : No other type of source inside the EUT. 4.4 rotection against hazardous moving parts General No hazardous moving part in operator access areas rotection in operator access areas... : No hazardous moving part in operator access areas. Household and home/office document/media shredders No hazardous moving part in operator access areas rotection in restricted access locations... : No hazardous moving part in operator access areas rotection in service access areas No hazardous moving part in operator access areas rotection against moving fan blades No hazardous moving part in operator access areas General No hazardous moving part in operator access areas. Not considered to cause pain or injury. a) : No hazardous moving part in operator access areas. Is considered to cause pain, not injury. b)...: No hazardous moving part in operator access areas. Considered to cause injury. c) : No hazardous moving part in operator access areas rotection for users No hazardous moving part in operator access areas. Use of symbol or warning..: No hazardous moving part in operator access areas rotection for service persons No hazardous moving part in operator access areas. Use of symbol or warning..: No hazardous moving part in operator access areas. 4.5 Thermal requirements General Considered Temperature tests (see appended table 4.5) Normal load condition per Annex L... : See operation condition under Summary of testing Temperature limits for materials (see appended table 4.5)

24 age 24 of 94 Report No.: CB170707E IEC Touch temperature limits (see appended table 4.5) Resistance to abnormal heat... : No such construction inside the EUT. 4.6 Openings in enclosures Top and side openings The EUT is transportable equipment, see Clause Dimensions (mm)... : Bottoms of fire enclosures The EUT is transportable equipment, see Clause Construction of the bottomm, dimensions (mm).. : Doors or covers in fire enclosures No such doors or covers Openings in transportable equipment No opening provided Constructional design measures No opening provided. Dimensions (mm)... : Evaluation measures for larger openings No opening provided Use of metallized parts No metalized parts Adhesives for constructional purposes No adhesives for construction purposes. Conditioning temperature (C), time (weeks)... : The EUT is transportable equipment, see Clause Resistance to fire Reducing the risk of ignition and spread of flame See below. Method 1, selection and application of components wiring and materials Method 2, application of all of simulated fault condition tests Selection of components for the simulation of faults with acceptable results, and use of materials with the required flammability class. Method 1 used Conditions for a fire enclosure See below arts requiring a fire enclosure See clause arts not requiring a fire enclosure For the EUT, the components in the secondary circuits supplied by Limited ower Sources and the components are mounted on CB material of flammability class V-1 or better, thus the fire enclosure construction is not required. The battery pack body covered by plastic material of flammability class V-0 or better and internal metal chassis.

25 age 25 of 94 Report No.: CB170707E IEC Materials General See appended table for CB Materials for fire enclosures See clause Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures HB or better. Electronics components are mounted on V-1 CB. No internal parts can produce temperature that could cause ignition, and all others parts are not concerned by the first three requirements of this clause Materials for air filter assemblies No air filter provided Materials used in high-voltage components No high-voltage component inside the equipment. 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 5.1 Touch current and protective conductor current General See below Configuration of equipment under test (EUT) Class III equipment, supplied by SELV Single connection to an a.c. mains supply Class III equipment. Not to connect to a.c. mains directly Redundant multiple connections to an a.c. mains supply Simultaneous multiple connections to an a.c. mains supply No such construction. No such construction Test circuit Class III equipment, supplied by SELV Application of measuring instrument Class III equipment, supplied by SELV Test procedure Class III equipment, supplied by SELV Test measurements Class III equipment, supplied by SELV. Supply voltage (V)...: Measured touch current (ma)...: Max. allowed touch current (ma)...: Measured protective conductor current (ma)...: Max. allowed protective conductor current (ma)...: Equipment with touch current exceeding 3,5 ma Class III equipment, supplied by SELV.

26 age 26 of 94 Report No.: CB170707E IEC General...: Class III equipment, supplied by SELV Simultaneous multiple connections to the supply No such construction Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network or to a cable distribution system EUT is not connected to a telecommunication system and a cable distribution system. EUT is not connected to a telecommunication system and a cable distribution system. Supply voltage (V)...: -- Measured touch current (ma)...: -- Max. allowed touch current (ma)...: Summation of touch currents from telecommunication networks EUT is not connected to a telecommunication system and a cable distribution system. a) EUT with earthed telecommunication ports...: EUT is not connected to a telecommunication system and a cable distribution system. b) EUT whose telecommunication ports have no reference to protective earth EUT is not connected to a telecommunication system and a cable distribution system. 5.2 Electric strength General Class III equipment, supplied by SELV Test procedure Class III equipment, supplied by SELV. 5.3 Abnormal operating and fault conditions rotection against overload and abnormal operation See below Motors Stepping motor used Transformers Class III equipment, supplied by SELV Functional insulation...: Method c) used. Result see appended table Electromechanical components No electromechanical component Audio amplifiers in ITE...: No hazard Simulation of faults See appended table Unattended equipment No such component Compliance criteria for abnormal operating and fault conditions No flame in the equipment. No molten metal was emitted.

27 age 27 of 94 Report No.: CB170707E IEC During the tests No flame in the equipment. No molten metal was emitted After the tests No consequent testing necessary. 6 CONNECTION TO TELECOMMUNICATION NETWORKS 6.1 rotection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment rotection from hazardous voltages Separation of the telecommunication network from earth Requirements Not connected to the telecommunication network. Supply voltage (V)... : Current in the test circuit (ma)... : Exclusions... : Not connected to the telecommunication network. 6.2 rotection of equipment users from overvoltages on telecommunication networks Separation requirements Not connected to the telecommunication network Electric strength test procedure Not connected to the telecommunication network Impulse test Not connected to the telecommunication network Steady-state test Not connected to the telecommunication network Compliance criteria Not connected to the telecommunication network. 6.3 rotection of the telecommunication wiring system from overheating Max. output current (A)... : Current limiting method... : The EUT is not intended to supply other units via telecommunication line. 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS 7.1 General Not connected to the cable distribution system. 7.2 rotection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment Not connected to the cable distribution system.

28 age 28 of 94 Report No.: CB170707E IEC rotection of equipment users from overvoltages on the cable distribution system 7.4 Insulation between primary circuits and cable distribution systems Not connected to the cable distribution system. Not connected to the cable distribution system General Not connected to the cable distribution system Voltage surge test Not connected to the cable distribution system Impulse test Not connected to the cable distribution system. A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see ) The mass of the EUT is less than 18kg A.1.1 Samples... : Wall thickness (mm)... : A.1.2 Conditioning of samples; temperature (C)... : A.1.3 Mounting of samples... : A.1.4 Test flame (see IEC ) Flame A, B, C or D... : A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material... : Wall thickness (mm)... : A.2.2 Conditioning of samples; temperature ( C)... : A.2.3 Mounting of samples... : A.2.4 Test flame (see IEC ) Flame A, B or C... : A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... :

29 age 29 of 94 Report No.: CB170707E IEC A.2.7 Alternative test acc. to IEC , cl. 5 and 9 Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see and 5.3.2) B.1 General requirements Stepping motor used. osition... : Manufacturer... : Type... : Rated values... : B.2 Test conditions B.3 Maximum temperatures B.4 Running overload test B.5 Locked-rotor overload test Test duration (days)... : Electric strength test: test voltage (V)... : B.6 Running overload test for d.c. motors in secondary circuits B.6.1 General B.6.2 Test procedure B.6.3 Alternative test procedure B.6.4 Electric strength test; test voltage (V)... : B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 General B.7.2 Test procedure B.7.3 Alternative test procedure B.7.4 Electric strength test; test voltage (V)... : B.8 Test for motors with capacitors B.9 Test for three-phase motors B.10 Test for series motors Operating voltage (V)... :

30 age 30 of 94 Report No.: CB170707E IEC C ANNEX C, TRANSFORMERS (see and 5.3.3) osition... : Manufacturer... : Type... : Rated values... : Method of protection... : Class III equipment, supplied by SELV. Class III equipment, supplied by SELV. Class III equipment, supplied by SELV. Class III equipment, supplied by SELV. Class III equipment, supplied by SELV. C.1 Overload test Class III equipment, supplied by SELV. C.2 Insulation Class III equipment, supplied by SELV. rotection from displacement of windings... : D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) D.1 Measuring instrument Class III equipment, supplied by SELV and no direct connection to the mains. D.2 Alternative measuring instrument E ANNEX E, TEMERATURE RISE OF A WINDING (see ) F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEAGE DISTANCES (see 2.10 and Annex G) G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES G.1 Clearances Not used. G.1.1 General Not used. G.1.2 Summary of the procedure for determining minimum clearances Not used. G.2 Determination of mains transient voltage (V) Not used. G.2.1 AC mains supply... : G.2.2 Earthed d.c. mains supplies... : G.2.3 Unearthed d.c. mains supplies... : G.2.4 Battery operation... : G.3 Determination of telecommunication network transient voltage (V)... : Not used.

31 age 31 of 94 Report No.: CB170707E IEC G.4 Determination of required withstand voltage (V) Not used. G.4.1 Mains transients and internal repetitive peaks... : G.4.2 Transients from telecommunication networks... : G.4.3 Combination of transients G.4.4 Transients from cable distribution systems G.5 Measurement of transient voltages (V) Not used. a) Transients from a mains supply For an a.c. mains supply For a d.c. mains supply b) Transients from a telecommunication network G.6 Determination of minimum clearances... : Not used. H ANNEX H, IONIZING RADIATION (see ) J ANNEX J, TABLE OF ELECTROCHEMICAL OTENTIALS (see ) Metal(s) used... : K ANNEX K, THERMAL CONTROLS (see and 5.3.8) K.1 Making and breaking capacity No thermal control in the EUT. K.2 Thermostat reliability; operating voltage (V)... : No thermal control in the EUT. K.3 Thermostat endurance test; operating voltage (V)... : K.4 Temperature limiter endurance; operating voltage (V)... : No thermal control in the EUT. No thermal control in the EUT. K.5 Thermal cut-out reliability No thermal control in the EUT. K.6 Stability of operation No thermal control in the EUT. L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYES OF ELECTRICAL BUSINESS EQUIMENT (see and 4.5.2) L.1 Typewriters No such device in the EUT. L.2 Adding machines and cash registers No such device in the EUT. L.3 Erasers No such device in the EUT. L.4 encil sharpeners No such device in the EUT. L.5 Duplicators and copy machines No such device in the EUT. L.6 Motor-operated files No such device in the EUT. L.7 Other business equipment See operation condition under Summary of testing. M ANNEX M, CRITERIA FOR TELEHONE RINGING SIGNALS (see 2.3.1)

32 age 32 of 94 Report No.: CB170707E IEC M.1 Introduction M.2 Method A M.3 Method B M.3.1 Ringing signal M Frequency (Hz)... : M Voltage (V)... : M Cadence; time (s), voltage (V)... : M Single fault current (ma)... : M.3.2 Tripping device and monitoring voltage... : M Conditions for use of a tripping device or a monitoring voltage M Tripping device M Monitoring voltage (V)... : N ANNEX N, IMULSE TEST GENERATORS (see , , , , 7.3.2, and Clause G.5) N.1 ITU-T impulse test generators Not used. N.2 IEC impulse test generator Not used. ANNEX, NORMATIVE REFERENCES Q ANNEX Q, Voltage dependent resistors (VDRs) (see ) - referred climatic categories... : No such components used - Maximum continuous voltage... : No such components used - Combination pulse current... : No such components used Body of the VDR Test according to IEC : Body of the VDR. Flammability class of material ( min V-1)...: No such components used No such components used R ANNEX R, EXAMLES OF REQUIREMENTS FOR QUALITY CONTROL ROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S ANNEX S, ROCEDURE FOR IMULSE TESTING (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing

33 age 33 of 94 Report No.: CB170707E IEC T ANNEX T, GUIDANCE ON ROTECTION AGAINST INGRESS OF WATER (see 1.1.2) U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see ) No such construction V ANNEX V, AC OWER DISTRIBUTION SYSTEMS (see 1.6.1) V.1 Introduction Class III equipment, no direct connection to the mains. V.2 TN power distribution systems Class III equipment, no direct connection to the mains. W ANNEX W, SUMMATION OF TOUCH CURRENTS W.1 Touch current from electronic circuits W.1.1 Floating circuits W.1.2 Earthed circuits W.2 Interconnection of several equipments W.2.1 Isolation W.2.2 Common return, isolated from earth W.2.3 Common return, connected to protective earth X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) X.1 Determination of maximum input current X.2 Overload test procedure Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see ) Y.1 Test apparatus... : Not used. Y.2 Mounting of test samples... : Not used. Y.3 Carbon-arc light-exposure apparatus... : Not used. Y.4 Xenon-arc light exposure apparatus... : Not used. Z ANNEX Z, OVERVOLTAGE CATEGORIES (see and Clause G.2) AA ANNEX AA, MANDREL TEST (see )

34 age 34 of 94 Report No.: CB170707E IEC BB ANNEX BB, CHANGES IN THE SECOND EDITION CC ANNEX CC, Evaluation of integrated circuit (IC) current limiters CC.1 General CC.2 Test program 1.: CC.3 Test program 2.: CC.4 Test program 3...: CC.5 Compliance...: DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment DD.1 General No such construction. DD.2 Mechanical strength test, variable N..: No such construction. DD.3 Mechanical strength test, 250N, including end stops : No such construction. DD.4 Compliance.: No such construction. EE ANNEX EE, Household and home/office document/media shredders EE.1 General Not such equipment EE.2 Markings and instructions Not such equipment Use of markings or symbols : Not such equipment Information of user instructions, maintenance and/or servicing instructions : Not such equipment EE.3 Inadvertent reactivation test : Not such equipment EE.4 Disconnection of power to hazardous moving parts: Not such equipment Use of markings or symbols : Not such equipment EE.5 rotection against hazardous moving parts Not such equipment Test with test finger (Figure 2A) : Not such equipment Test with wedge probe (Figure EE1 and EE2) : Not such equipment

35 age 35 of 94 Report No.: CB170707E IEC TABLE: List of critical components Object/part No. Manufacturer/ trademark Type/model Technical data Standard (Edition / year) Mark(s) of conformity 1 ) LCD anel with LED backlight design lastic enclosure material (covering battery pack) lastic enclosure material (decorated part) SHENZHEN TONGXINGDA TECHNOLOGY CO., LTD HONGFUJIN RECISION INDUSTRY (SZ) CO LTD TEIJIN LIMITED RESIN AND LASTIC TXDY400NWV C-22 C2400E L-1250Z 3.97 TFT LCD IEC Tested in the appliance. V-0, 80 C, request thickness is min. 1.6mm, measured thickness is min.2.5mm V-2,115 C, request thickness is min. 0.84mm, measured thickness is min.1.1mm UL 94 UL 94 UL (UL ref. no.: E323548) UL (UL ref. no.: E50075) - Alternate use Interchangeable Interchangeable HB min., 75C min. Required thickness shall comply with the minimum requirement of its certification. UL 94 UL - Description: Interchangeability based on standardized dimensions and specified rating CB material GULTECH (WUXI) ELECTRONICS CO LTD 17 V-0, 130 C UL 796 UL (UL ref. no.: E244417) - Alternate use Interchangeable Interchangeable V-1 min., 105C min. UL 796 UL - Description: Interchangeability based on standardized dimensions and specified rating Vibrator ALS ELECTRIC CO., LTD 2CJ-00017AA 5Vdc max., 105C, IEC Tested in the appliance. Rated current: 90mA max. Flash LED Lite-On Technology Optoelectronics LTL- C0698DAYD DC 150mA, Risk 1 Group IEC Test report (Issued by TUV/SUD, report No )

36 age 36 of 94 Report No.: CB170707E IEC Battery pack Energy Master Limited FT S 7.4Vdc, 2000mAh, 14.8Wh IEC : 2005 (Second Edition) + Am 1: Am 2: 2013 The requirements of IEC 62133: 2012 also tested in this report Supplementary information: 1) rovided evidence ensures the agreed level of compliance. See OD-CB2039. UL CB CB cert. DK UL

37 age 37 of 94 Report No.: CB170707E IEC TABLE: Electrical data (in normal conditions) U (V) I (A) Irated (A) (W) Fuse # Ifuse (A) Condition/status 5Vdc Maximum normal load (The EUT was supplied by external power supply when charging the completed discharged built-in battery pack.) 7.4Vdc Maximum normal load (The EUT was supplied by completed charged built-in battery pack.) Supplementary information: c) 1) TABLE: max. V, A, VA test Voltage (rated) (V) Current (rated) (A) Voltage (max.) (V) Current (max.) (A) VA (max.) (VA) Supplementary information: For adapter, the test has been evaluated in the adapter s test report c) 2) TABLE: stored energy Capacitance C (µf) Voltage U (V) Energy E (J) Supplementary information: TABLE: evaluation of voltage limiting components in SELV circuits Component (measured between) max. voltage (V) (normal operation) V peak V d.c Fault test performed on voltage limiting components Voltage Limiting Components Voltage measured (V) in SELV circuits (V peak or V d.c.) Supplementary information: The test has been evaluated in the adapter s test report.

38 age 38 of 94 Report No.: CB170707E IEC TABLE: Limited power sources Circuit output tested: Note: Measured Uoc (V) with all load circuits disconnected: Components Test condition (Single fault) Uoc (V) I sc (A) VA Meas. Limit Meas. Limit Micro SD(J5) O Supplementary information: Sc=Short circuit, Oc=Open circuit Table: working voltage measurement Location RMS voltage (V) eak voltage (V) Comments Supplementary information: The test has been evaluated in the adapter s test report and TABLE: Clearance and creepage distance measurements Clearance (cl) and creepage distance (cr) at/of/between: U peak (V) U r.m.s. (V) Required cl (mm) cl (mm) Required cr (mm) cr (mm) Functional: Basic/supplementary: Reinforced: Supplementary information: The distances of adapter have been evaluated in the adapter s test report TABLE: Distance through insulation measurements Distance through insulation (DTI) at/of: U peak (V) U rms (V) Test voltage (V) Required DTI (mm) DTI (mm) Supplementary information: The test has been evaluated in the adapter s test report TABLE: Batteries The tests of are applicable only when appropriate battery data is not available --

39 age 39 of 94 Report No.: CB170707E IEC Is it possible to install the battery in a reverse polarity position? No Max. current during normal condition Max. current during fault condition (EUT main board IC (U6) in A2-D4 short) Max. current during fault condition (EUT main board IC (U6) in D4-B2 short) Max. current during fault condition (Battery pack main board IC (Q2) in 1-3 short) Max. current during fault condition (Battery pack main board IC (Q1) in 1-3 short) Non-rechargeable batteries Discharging Meas. current Manuf. Specs. Unintentional charging Rechargeable batteries Charging Discharging Reversed charging Meas. current Manuf. Specs. Meas. current Manuf. Specs. Meas. current Manuf. Specs A 1.95A 0.489A 3.90A A 1.95A A 3.90A A 1.95A A 3.90A Test results: - Chemical leaks No chemical leaks. - Explosion of the battery No explosion. - Emission of flame or expulsion of molten metal No emission of flame or expulsion of molten metal Verdict - Electric strength tests of equipment after completion of tests No isolation requirement. Supplementary information: TABLE: Batteries Battery category... : Lithium-ion Manufacturer... : Energy Master Limited Type / model... : FT S Voltage... : 7.4Vdc Capacity... : 2000mAh Tested and Certified by (incl. Ref. No.)... : CB certified by UL DEMKO, CB cert. DK UL

40 age 40 of 94 Report No.: CB170707E IEC Circuit protection diagram: See below MARKINGS AND INSTRUCTIONS ( ) Location of replaceable battery Language(s).: Close to the battery.: In the servicing instructions : In the operating instructions..: Inside the Mobile hone English No Yes Yes 4.5 TABLE: Thermal requirements Supply voltage (V)... : 5Vdc 7.4Vdc Ambient T min (C)... : Ambient T max (C)... : Maximum measured temperature T of part/at...: Test condition: The EUT was supplied by external power supply when charging the completed discharged built-in battery pack. T (C) The EUT was supplied by completed charged built-in battery pack. Calculated value for Tma: C106 body Allowe d T max (C) --

41 age 41 of 94 Report No.: CB170707E IEC L4 coil WB under IC (U22) WB under IC (U18) WB under IC (U29) Vibrator body Battery pack body lastic enclosure inside near battery pack lastic enclosure outside near battery pack anel body Supplementary information: Temperature T of winding: t 1 ( C) R 1 () t 2 ( C) R 2 () T (C) Allowed T max (C) Insulatio n class Supplementary information: 1. The temperatures were measured under worst case normal mode defined in summary of testing and as described in at voltages as above. 2. The maximum permitted temperatures are as follows: Components with: - max. absolute temp. of 100 C (Battery) Tmax( C) = 100 C - max. absolute temp. of 105 C (WB, Vibrator, chock, Capacitor) Tmax( C) = 105 C User accessible area: - lastic material (75 C) Tmax( C)= 75 C TABLE: Ball pressure test of thermoplastic parts art Allowed impression diameter (mm)... : 2 mm Test temperature (C) Impression diameter (mm) Supplementary information: The test has been evaluated in the adapter s test report. 4.7 TABLE: Resistance to fire art Manufacturer of material Type of material Thickness (mm) Flammability class Evidence

42 age 42 of 94 Report No.: CB170707E IEC lastic enclosure(covering battery pack) HONGFUJIN RECISION INDUSTRY (SZ) CO LTD C2400E Min. 2.5 mm V-0 UL Supplementary information: The materials of adapter have been evaluated in the adapter s test report 5.1 TABLE: touch current measurement Measured between: Measured (ma) Limit (ma) Comments/conditions Supplementary information: The test has been evaluated in the adapter s test report. 5.2 TABLE: Electric strength tests, impulse tests and voltage surge tests Test voltage applied between: Voltage shape (AC, DC, impulse, surge) Test voltage (V) Breakdo wn Yes / No Supplementary information: For adapter, the test has been evaluated in the adapter s test report. 5.3 TABLE: Fault condition tests Component No. IC (U501) pin 3 2 IC (U503) pin 3 2 IC (U504) pin 3 2 Battery pack V+ to V- Ambient temperature (C)... : 25, if not specified. ower source for EUT: Manufacturer, model/type, output rating... : Fault Supply voltage (V) Test time Fuse # -- Fuse current (A) Observation Short 5Vdc 30min Unit shutdown. No hazard, no damage. Short 5Vdc 30min Unit operated normally. No hazard, no damage. Short 5Vdc 30min Unit operated normally. No hazard, no damage. Short Fully charged battery pack 30min Unit shutdown. No hazard, no damage. EUT Main Board (IC (U6) in A2- D4 short) Overcharge 5Vdc 7.0hrs Charging current= 0A, no hazards

43 age 43 of 94 Report No.: CB170707E IEC EUT Main Board (IC (U6) in D4- B2 short) Battery pack Main Board IC (Q2) in 1-3 short Battery pack Main Board IC (Q1) in 1-3 short Over discharge Fully charged battery pack 7.0hrs Discharging current= 0.490A, no hazards Overcharge 5Vdc 7.0hrs Charging current= 0.013A, no hazards Over discharge Supplementary information: Fully charged battery pack 7.0hrs Discharging current= 0.490A, no hazards

44 age 44 of 94 Report No.: CB170707E IEC C.2 TABLE: transformers Loc. Tested insulation Working voltage peak / V (2.10.2) Working voltage rms / V (2.10.2) Required electric strength (5.2) Required clearance / mm (2.10.3) Required creepage distance / mm (2.10.4) Loc. Tested insulation Test voltage/ V Measured clearance / mm Measured creepage dist./ mm Supplementary information: The test has been evaluated in the adapter s test report. Required distance thr. insul. (2.10.5) Measured distance thr. insul. / mm; number of layers C.2 TABLE: transformers The construction of transformer has been evaluated in the adapter s test report.

45 age 45 of 94 Report No.: CB160819C List of test equipment used: A completed list of used test equipment shall be provided in the Test Reports when a Manufacturer Testing Laboratory according to TM/CTF stage 1 or WMT/CTF stage 2 procedure has been used. Clause Measurement / testing Testing / measuring equipment / material used Range used Calibration date

46 age 46 of 94 Report No.: CB160819C24 003

47 age 47 of 94 Report No.: CB160819C24 003

48 age 48 of 94 Report No.: CB160819C24 003

49 age 49 of 94 Report No.: CB160819C24 003

50 age 50 of 94 Report No.: CB160819C24 003

51 age 51 of 94 Report No.: CB160819C24 003

52 age 52 of 94 Report No.: CB160819C24 003

53 age 53 of 94 Report No.: CB160819C24 003

54 age 54 of 94 Report No.: CB160819C24 003

55 age 55 of 94 Report No.: CB160819C24 003

56 age 56 of 94 Report No.: CB160819C General view - 1 General view - 2

57 age 57 of 94 Report No.: CB160819C General view - 3 Internal view - 1

58 age 58 of 94 Report No.: CB160819C Internal view - 2 Internal view - 3

59 age 59 of 94 Report No.: CB160819C Internal view - 4 Main board view - 1

60 age 60 of 94 Report No.: CB160819C Main board view - 2 Battery view -1

61 age 61 of 94 Report No.: CB160819C Battery view - 2 Main board view of Battery ack- 1

62 age 62 of 94 Report No.: CB160819C Main board view of Battery ack- 2

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1712057S.50A Date of issue... : 2017-04-13 Total number

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

A Test Lab Techno Corp.

A Test Lab Techno Corp. Report No. 1607CF12 age 1 of 52 TEST REORT AS/NZS60950.1:2011+A1:2013 Safety of Information Technology Equipment including Electrical business equipment Report Number.... : 1607CF12 Date of issue... :

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30

More information

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences:

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences: age 3 of 106 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. re-production samples without serial

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 55 Report No.:L611332L009 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number.... : TEST REORT Information technology equipment Safety art 1: General requirements Date of issue... : 7 March, 2017 Total number of pages...

More information

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements age 1 of 49 Report Reference No....: 80983 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2008 TEST REORT :2006 Information technology equipment Safety art 1: General

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009.

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009. ELECTRICAL TESTING 839.01 Hermon Laboratories Ltd. Tel.+972 4 628 8001 Fax.+972 4 628 8277 SAFETY TEST REPORT ACCORDING TO: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, IEC 60950-1:2005 (Second Edition)

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 46 TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 160414015SZN-002 Date of issue... : May 09, 2016 Total number of pages... : 77 pages Applicant

More information

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A Ratings...: age 2 of 41 Report o.: CTL1607012503-WS Adapter: Input: 100-240Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A age 3 of 41 Report o.: CTL1607012503-WS Summary of testing: Testing

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2006-05-11 Page 1 of 2 Report Reference # E212360-A19-UL-1 Amendment 2 2009-07-03 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference:

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : 251006 2345690 (-2502294) Date of issue...

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 248792 Date of issue... : 2013-11-25

More information

Summary of testing: Testing location: Tests performed (name of test and test clause): Summary of compliance with National Differences:

Summary of testing: Testing location: Tests performed (name of test and test clause): Summary of compliance with National Differences: age 3 of 71 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. Testing location: All tests as described

More information

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: T223-0035/16 Date of issue...: 2016-02-01

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements Page 1 of 49 Report Reference No....: 81790 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2009 TEST REPORT :2006 Information technology equipment Safety Part 1: General

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 72 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: GLOBAL ADVANTAGE INTERNATIONAL TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

Audio/video, information and communication technology equipment Part 1: Safety requirements

Audio/video, information and communication technology equipment Part 1: Safety requirements Test Report issued under the responsibility of: TEST REORT Audio/video, information and communication technology equipment art 1: Safety requirements Report Number... : 151101256SHA-001 Date of issue...

More information

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77 TECHNICAL REORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION SYSTEM NERA F77 ACCORDING TO EN 60950 (2000) REORT NO. 2002-3032 REVISION NO. 01 DET NORSKE VERITAS DET NORSKE VERITAS TECHNICAL

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of GUAGDOG EAST OWER CO., LTD. Uninterruptible ower Supply Model(s): EA99300,EA99250,EA99200 repared For : GUAGDOG EAST OWER CO., LTD. o.6 orthern Industry

More information

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2011-01-12 Page 1 of 1 Report Reference # ASL10120310 COVER PAGE FOR TEST REPORT Test Item Description: Notebook PC Model/Type Reference: MS-16Y1 Rating(s): 19Vdc, 3.42A or 19Vdc, 4.74A Standards:

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

Audio/video, information and communication technology equipment Part 1: Safety requirements

Audio/video, information and communication technology equipment Part 1: Safety requirements age 1 of 50 TEST REORT Audio/video, information and communication technology equipment art 1: Safety requirements Report Number... : 68.210.18.0025.01 Date of issue... : 2018-03-19 Total number of pages...

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2008-11-11 Page 1 of 2 Report Reference # E186249-A82-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

Test Report issued under the responsibility of: Report Number...:

Test Report issued under the responsibility of: Report Number...: Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

Part 1: General requirements for basic safety and essential performance

Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REORT art 1: General requirements for basic safety and essential performance Report Number.... : 130501061SHA-001 Date of issue... : 2013-07-01 Total

More information

IEC and/or EN Safety of information technology equipment

IEC and/or EN Safety of information technology equipment R904.023.1 Kontron Single Board Computer JRex entium-m 1.6G (BQBA) Customer: Kontron Embedded Modules GmbH Brunnwiesenstrasse 16 94469 Deggendorf (0991) 3 70 24-0 (0991) 3 70 24-16 The test result refers

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 11 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information