5 Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Report Number.... : Date of issue... : Total number of pages CB Testing Laboratory... : Address... : Applicant s name... : Address... : Manufacturer s name.: Address... : Test specification: TÜV SÜD Asia Ltd. Taiwan Branch 7F., No.37, Sec. 2, Zhongyang S., Rd., Beitou District, Taipei City, 11270, Taiwan. Logitech Far East Ltd. 2,Creation Rd.4, Science-Based Industrial Park, Hsinchu TAIWAN Logitech Far East Ltd. 2,Creation Rd.4, Science-Based Industrial Park, Hsinchu TAIWAN Standard... : IEC :2005 (Second Edition), Am 1: 2009 Test procedure... : Non-standard test method..: Test Report Form No.... : Test Report Form(s) Originator... : CB Scheme IEC60950_1B SGS Fimko Ltd Master TRF... : Dated Copyright 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : Trade Mark... : Manufacturer... : Model/Type reference... : Ratings... : WebCam or Same as applicant V-U Vdc, 500 ma 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 1 of 41 Test Report IEC60950_1B

6 Testing procedure and testing location: CB Testing Laboratory: TÜV SÜD Asia Ltd. Taiwan Branch Testing location/ address... : 7F., No.37, Sec. 2, Zhongyang S., Rd., Beitou District, Taipei City, 11270, Taiwan. Associated CB Laboratory: Testing location/ address... : Tested by (name + signature)... : Approved by (name + signature)... : Testing procedure: TMP Testing location/ address...: Mr. Owen Hsu Mr. Watson Yang Tested by (name + signature)... : Approved by (name + signature)... : Testing procedure: WMT Testing location/ address...: Tested by (name + signature)... : Witnessed by (name + signature)... : Approved by (name + signature)... : Testing procedure: SMT Testing location/ address...: Tested by (name + signature)... : Approved by (name + signature)... : Supervised by (name + signature)... : Testing procedure: RMT Testing location/ address...: Tested by (name + signature)... : Approved by (name + signature)... : Supervised by (name + signature)... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 2 of 41 Test Report IEC60950_1B

7 List of Attachments (including a total number of pages in each attachment): Attachments No. 1 Group and National Differences 53 pages (for IEC nd Ed) Attachments No. 2 Group and National Differences (for IEC st Ed) 50 pages Attachments No. 3 Marking Plate 2 pages Attachments No. 4 Photo 3 pages Summary of testing: Tests performed (name of test and test clause): All test results were found satisfactory in accordance with IEC :2005 (2 nd Edition) + A1: 2009 and EN : A11: A1: A12:2011 Testing location: All tests as described in Test Case and Measurement Sections were performed at the laboratory described on page 2. Summary of compliance with National Differences List of countries addressed: For IEC :2005 (2 nd Edition ) Am 1: 2009 and EN : A11: A1: A12:2011 According to CB Bulletin, the National Differences include Australia (AU), Canada (CA), Germany (DE), Israel (IL), Korea (KR), Switzerland (CH) and United States of America (US). Group Differences (CENELEC COMMON MODIFICATIONS) as listed in the European Standard are recorded in this Report. (Attachment No. 1) For IEC :2001 (1 st Edition) and EN :2001+A11:2004 According to CB Bulletin, the National Differences include Australia (AU), Canada (CA), Japan (JP), Korea (KR), Sweden (SE), Switzerland (CH) and United States of America (US). Group Differences (CENELEC COMMON MODIFICATIONS) as listed in the European Standard are recorded in this Report. (Attachment No. 2) The product fulfils the requirements of IEC : A1:2009/ EN : A11: A1: A12: F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 3 of 41 Test Report IEC60950_1B

8 Copy of marking plate The artwork below may be only a draft. The use of certification marks on a product must be authorized by the respective NCBs that own these marks. (Additional requirements for markings. See 1.7 NOTE) See attachment No. 3 ( Total 2 pages ) 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 4 of 41 Test Report IEC60950_1B

9 Test item particulars... : Equipment mobility... : [X] movable [] hand-held [] transportable [] stationary [] for building-in [] direct plug-in Connection to the mains...: [] pluggable equipment [] type A [] type B [] permanent connection [] detachable power supply cord [] non-detachable power supply cord [X] not directly connected to the mains Operating condition...: [X] continuous [] rated operating / resting time: Access location...: [X] operator accessible [] restricted access location Over voltage category (OVC)...: [] OVC I [] OVC II [] OVC III [] OVC IV [X] other: not directly connected to AC or DC mains. Mains supply tolerance (%) or absolute mains supply values...: Tested for IT power systems...: [] Yes IT testing, phase-phase voltage (V)... : [X] No Class of equipment...: [] Class I [] Class II [X] Class III [] Not classified Considered current rating of protective device as part of the building installation (A)...: Pollution degree (PD)...: [] PD 1 [X] PD 2 [] PD 3 IP protection class... : Ordinary Altitude during operation (m)... : Up to 2000 Altitude of test laboratory (m)... : below 2000 Mass of equipment (kg)... : Approx.0.17 Possible test case verdicts: - test case does not apply to the test object... : (or N) - test object does meet the requirement... : P (Pass) - test object does not meet the requirement... : F (Fail) Testing... : Date of receipt of test item... : Date(s) of performance of tests... : to F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 5 of 41 Test Report IEC60950_1B

10 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma / point is used as the decimal separator. Manufacturer s Declaration per sub-clause of IECEE 02: The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the sample(s) submitted for evaluation is (are) representative of the products from each factory has been provided...: Yes Not applicable When differences exist; they shall be identified in the General product information section. Name and address of factory (ies)... : 1. Logitech Technology (Suzhou) Co., Ltd. (ID No ) 3, Songshan Road, New District Suzhou City, PEOPLE'S REPUBLIC OF CHINA 2. Shang Hai Hank Connection Co., Ltd. (ID No ) No.9655 TingWei Road, TingLin Town, Jinshan Zone Shanghai, PEOPLE'S REPUBLIC OF CHINA General product information: The equipment is a WebCam of information technology equipment. The maximum ambient temperature specified by manufacturer is 40 C. The SELV circuits of a data port for connection of such equipment supplied by a limited power source. Due to the very low power consumption of the product no temperature testing was carried out as part of this assessment. All interfaces are SELV circuitry. Abbreviations used in the report: - normal conditions N.C. - single fault conditions S.F.C - functional insulation OP - basic insulation BI - double insulation DI - supplementary insulation SI - between parts of opposite polarity BOP - reinforced insulation RI Indicate used abbreviations (if any) 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 6 of 41 Test Report IEC60950_1B

11 IEC/EN GENERAL P 1.5 Components P General See below. P Comply with IEC or relevant component standard Components which were found to affect safety aspects comply with the requirements of this standard or within the safety aspects of the relevant IEC component standards. (See appended table 1.5.1) Evaluation and testing of components Components which are certified to IEC and/or national standards are used correctly within their ratings. Components not covered by IEC standards are tested under the conditions present in the equipment Thermal controls No thermal control Transformers No transformers provided. P P Interconnecting cables Interconnection o/p cable to other device is carrying only SELV voltages on an energy level below 240 VA. Except for the insulation material, there is no further requirement to the o/p interconnection cable Capacitors bridging insulation The equipment is supplied from SELV voltages only, no connection to mains. P Resistors bridging insulation No connection to mains Resistors bridging functional, basic or supplementary insulation Resistors bridging double or reinforced insulation between a.c. mains and other circuits Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable Components in equipment for IT power systems Only SELV inside, no connection to mains. 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 7 of 41 Test Report IEC60950_1B

12 IEC/EN Surge suppressors Only SELV circuit in this equipment General Protection of VDRs Bridging of functional insulation by a VDR Bridging of basic insulation by a VDR Bridging of supplementary, double or reinforced insulation by a VDR 1.6 Power interface P AC power distribution systems Equipment is not directly connected to the AC mains supply Input current Highest load according to for this equipment is unit connected to a simulator and operated continuously. (See appended table) Voltage limit of hand-held equipment This equipment is not handheld equipment Neutral conductor Only SELV inside equipment, no connection to mains. P 1.7 Marking and instructions P Power rating and identification markings See clause and Power rating marking See below. P Multiple mains supply connections...: No connection to mains. Rated voltage(s) or voltage range(s) (V)... : 5 Vdc P Symbol for nature of supply, for d.c. only... : Rated frequency or rated frequency range (Hz)... : DC Source. Rated current (ma or A)... : 500 ma P Identification markings See marking plate. P Manufacturer s name or trade-mark or identification mark... : Trademark: or P P P 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 8 of 41 Test Report IEC60950_1B

13 IEC/EN Model identification or type reference... : V-U0028 P Symbol for Class II equipment only... : Other markings and symbols... : Additional symbols or markings that do not give rise to misunderstand Safety instructions and marking See below. P General The safety instruction contains information for installation, servicing, transport, storage and technical data. No other special installation instruction is required for Disconnect devices Only SELV inside, no connection to mains Overcurrent protective device Ditto IT power distribution systems Ditto Operator access with a tool Ozone Short duty cycles Equipment is designed for continuous operation Supply voltage adjustment... : No voltage/frequency setting. Methods and means of adjustment; reference to installation instructions... : Power outlets on the equipment... : No power outlet provided Fuse identification (marking, special fusing characteristics, cross-reference)... : Class III equipment, no protection fuse was provided Wiring terminals Protective earthing and bonding terminals... : Ditto Terminals for a.c. mains supply conductors Ditto Terminals for d.c. mains supply conductors Not applied for Controls and indicators See below Identification, location and marking... : No controls and indicators. P P Colours... : No safety involved colour identification Symbols according to IEC : No switches or controls Markings using figures...: No indicators for different positions. 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 9 of 41 Test Report IEC60950_1B

14 IEC/EN Isolation of multiple power sources...: Class III equipment not connected to the mains Thermostats and other regulating devices... : No thermostats used Durability The label was subjected to the permanence of marking test. The label was rubbed with cloth for 15 sec. and then again for 15 sec. with the cloth soaked with Petroleum Ether. After this test there was no damage to the label. The marking on the label did not fade. There was no curling or lifting of the label edge Removable parts Marking is not placed on removable part Replaceable batteries... : No replaceable batteries used. Language(s)... : Equipment for restricted access locations... : No restricted access location. P P 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 10 of 41 Test Report IEC60950_1B

15 IEC/EN PROTECTION FROM HAZARDS P 2.1 Protection from electric shock and energy hazards P Protection in operator access areas This equipment is the optical mouse with SELV circuit only. There is no any hazard Access to energized parts There are no energized parts inside of equipment. Test by inspection... : Ditto. Test with test finger (Figure 2A)... : Ditto. Test with test pin (Figure 2B)... : Ditto. Test with test probe (Figure 2C)... : No TNV circuit Battery compartments No battery compartments used Access to ELV wiring Only SELV inside. Working voltage (Vpeak or Vrms); minimum distance through insulation (mm) Access to hazardous voltage circuit wiring Only SELV inside Energy hazards... : No energy hazard in operator access area Manual controls No manual controls Discharge of capacitors in equipment No connected to the mains. Measured voltage (V); time-constant (s)... : Energy hazards d.c. mains supply a) Capacitor connected to the d.c. mains supply. : b) Internal battery connected to the d.c. mains supply... : Audio amplifiers... : Protection in service access areas No maintenance work in operation mode necessary Protection in restricted access locations No restricted access locations. P P P 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 11 of 41 Test Report IEC60950_1B

16 IEC/EN SELV circuits P General requirements The equipment supplied from SELV only Voltages under normal conditions (V)... : The equipment supplied from SELV only Voltages under fault conditions (V)... : Ditto. P Connection of SELV circuits to other circuits...: No direct connection between SELV and any primary circuits. P P 2.3 TNV circuits Limits No TNV circuits. Type of TNV circuits... : Separation from other circuits and from accessible parts General requirements Protection by basic insulation Protection by earthing Protection by other constructions... : Separation from hazardous voltages Insulation employed... : Connection of TNV circuits to other circuits Insulation employed... : Test for operating voltages generated externally 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 12 of 41 Test Report IEC60950_1B

17 IEC/EN Limited current circuits General requirements Limit values Frequency (Hz)... : Measured current (ma)... : Measured voltage (V)... : Measured circuit capacitance (nf or µf)... : Connection of limited current circuits to other circuits 2.5 Limited power sources a) Inherently limited output b) Impedance limited output c) Regulating network limited output under normal operating and single fault condition d) Overcurrent protective device limited output Max. output voltage (V), max. output current (A), max. apparent power (VA)... : Current rating of overcurrent protective device (A).: Use of integrated circuit (IC) current limiters 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 13 of 41 Test Report IEC60950_1B

18 IEC/EN Provisions for earthing and bonding Protective earthing Functional earthing Protective earthing and protective bonding conductors General Size of protective earthing conductors Rated current (A), cross-sectional area (mm 2 ), AWG... : Size of protective bonding conductors Rated current (A), cross-sectional area (mm 2 ), AWG... : Protective current rating (A), cross-sectional area (mm 2 ), AWG... : Resistance of earthing conductors and their terminations; resistance (), voltage drop (V), test current (A), duration (min)... : Colour of insulation... : Terminals General Protective earthing and bonding terminals Rated current (A), type, nominal thread diameter (mm)... : Separation of the protective earthing conductor from protective bonding conductors 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 14 of 41 Test Report IEC60950_1B

19 IEC/EN Integrity of protective earthing Interconnection of equipment Components in protective earthing conductors and protective bonding conductors Disconnection of protective earth Parts that can be removed by an operator Parts removed during servicing Corrosion resistance Screws for protective bonding Reliance on telecommunication network or cable distribution system 2.7 Overcurrent and earth fault protection in primary circuits Basic requirements No primary circuits inside the unit. Instructions when protection relies on building installation Faults not simulated in Short-circuit backup protection Number and location of protective devices... : Protection by several devices Warning to service personnel... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 15 of 41 Test Report IEC60950_1B

20 IEC/EN Safety interlocks General principles No safety interlock provided Protection requirements Inadvertent reactivation Fail-safe operation Protection against extreme hazard Moving parts Overriding Switches, relays and their related circuits Separation distances for contact gaps and their related circuits (mm)... : Overload test Endurance test Electric strength test Mechanical actuators 2.9 Electrical insulation Properties of insulating materials Only SELV circuit provided with the equipment Humidity conditioning Relative humidity (%), temperature ( C)... : Grade of insulation Separation from hazardous voltages Method(s) used... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 16 of 41 Test Report IEC60950_1B

21 IEC/EN Clearances, creepage distances and distances through insulation General Only SELV circuit is provided with equipment Frequency... : Pollution degrees... : Reduced values for functional insulation Intervening unconnected conductive parts Insulation with varying dimensions Special separation requirements Insulation in circuits generating starting pulses Determination of working voltage General RMS working voltage Peak working voltage Clearances General Mains transient voltages a) AC mains supply... : b) Earthed d.c. mains supplies... : c) Unearthed d.c. mains supplies... : d) Battery operation... : Clearances in primary circuits Clearances in secondary circuits Clearances in circuits having starting pulses Transients from a.c. mains supply... : Transients from d.c. mains supply... : Transients from telecommunication networks and cable distribution systems... : Measurement of transient voltage levels a) Transients from a mains supply For an a.c. mains supply... : For a d.c. mains supply... : b) Transients from a telecommunication network : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 17 of 41 Test Report IEC60950_1B

22 IEC/EN Creepage distances General Material group and comparative tracking index CTI tests...: Minimum creepage distances Solid insulation General Distances through insulation Insulating compound as solid insulation Not applied for Semiconductor devices Cemented joints Thin sheet material General Separable thin sheet material Number of layers (pcs)... : Non-separable thin sheet material Thin sheet material standard test procedure Electric strength test Thin sheet material alternative test procedure Electric strength test Insulation in wound components Wire in wound components Working voltage... : a) Basic insulation not under stress... : b) Basic, supplementary, reinforced insulation... : c) Compliance with Annex U... : Two wires in contact inside wound component; angle between 45 and : Wire with solvent-based enamel in wound components Electric strength test Routine test Additional insulation in wound components Working voltage... : - Basic insulation not under stress... : - Supplementary, reinforced insulation... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 18 of 41 Test Report IEC60950_1B

23 IEC/EN Construction of printed boards Uncoated printed boards Coated printed boards No coated printed board Insulation between conductors on the same inner surface of a printed board Insulation between conductors on different layers of a printed board Distance through insulation Number of insulation layers (pcs)... : Component external terminations Tests on coated printed boards and coated components Sample preparation and preliminary inspection Thermal conditioning Electric strength test Abrasion resistance test Thermal cycling Test for Pollution Degree 1 environment and insulating compound Tests for semiconductor devices and cemented joints Enclosed and sealed parts 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 19 of 41 Test Report IEC60950_1B

24 IEC/EN WIRING, CONNECTIONS AND SUPPLY P 3.1 General P Current rating and overcurrent protection No internal wire for primary power distribution. Internal wiring gauge is suitable for current intended to be carried Protection against mechanical damage Wires do not touch sharp edges which could damage the insulation and cause hazard Securing of internal wiring Internal wires with only basic isolation are routed so that they are not close to any live bare components. The wires are secured by solder terminals so that a loosening of the terminal connection is unlikely Insulation of conductors Insulation on internal conductors is considered to be of adequate quality and suitable for the application and the working voltage involved Beads and ceramic insulators Not used Screws for electrical contact pressure Ditto Insulating materials in electrical connections No contact pressure through insulation material Self-tapping and spaced thread screws No self tapping screws are used Termination of conductors The equipment is class III and contains SELV circuits only. 10 N pull test Sleeving on wiring No sleeves. P P P P 3.2 Connection to a mains supply Means of connection Class III equipment, no connection to mains Connection to an a.c. mains supply Connection to a d.c. mains supply Multiple supply connections Permanently connected equipment 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 20 of 41 Test Report IEC60950_1B

25 IEC/EN Number of conductors, diameter of cable and conduits (mm)... : Appliance inlets Power supply cords AC power supply cords Type... : Rated current (A), cross-sectional area (mm 2 ), AWG... : DC power supply cords Cord anchorages and strain relief Mass of equipment (kg), pull (N)... : Longitudinal displacement (mm)... : Protection against mechanical damage Cord guards Diameter or minor dimension D (mm); test mass (g)... : Radius of curvature of cord (mm)... : Supply wiring space 3.3 Wiring terminals for connection of external conductors Wiring terminals No connection to mains Connection of non-detachable power supply cords Screw terminals Conductor sizes to be connected Rated current (A), cord/cable type, cross-sectional area (mm 2 )... : Wiring terminal sizes Rated current (A), type, nominal thread diameter (mm)... : Wiring terminal design Grouping of wiring terminals Stranded wire No soft soldered wires under contact pressure. 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 21 of 41 Test Report IEC60950_1B

26 IEC/EN Disconnection from the mains supply General requirement Class III equipment, no connection to mains directly Disconnect devices Permanently connected equipment Parts which remain energized Switches in flexible cords Number of poles - single-phase and d.c. equipment Number of poles - three-phase equipment Switches as disconnect devices Plugs as disconnect devices Interconnected equipment Multiple power sources 3.5 Interconnection of equipment P General requirements See below. P Types of interconnection circuits... : Interconnection circuits of SELV through the connectors. No ELV interconnection circuits ELV circuits as interconnection circuits No ELV interconnection Data ports for additional equipment No output data port provided. P 4 PHYSICAL REQUIREMENTS P 4.1 Stability Angle of 10 This equipment is less than 7kg. Test force (N)... : Equipment is not a floor standing unit. 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 22 of 41 Test Report IEC60950_1B

27 IEC/EN Mechanical strength General Class III equipment, only SELV inside equipment. Rack-mounted equipment Steady force test, 10 N Steady force test, 30 N Steady force test, 250 N Impact test Fall test Swing test Drop test; height (mm)... : Stress relief test Cathode ray tubes No cathode ray tube. Picture tube separately certified... : High pressure lamps No high pressure lamp Wall or ceiling mounted equipment; force (N)... : Not wall or ceiling mounted equipment Rotating solid media Test to cover on the door.: 4.3 Design and construction P Edges and corners Edges and corners of the enclosure are rounded Handles and manual controls; force (N)... : Adjustable controls None such controls would cause hazard Securing of parts Not apply for Connection by plugs and sockets Only SELV connector Direct plug-in equipment The equipment is not a direct plug-in unit. Torque... : Compliance with the relevant mains plug standard... : Heating elements in earthed equipment No heating elements. P 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 23 of 41 Test Report IEC60950_1B

28 IEC/EN Batteries No batteries provided. - Overcharging of a rechargeable battery - Unintentional charging of a non-rechargeable battery - Reverse charging of a rechargeable battery - Excessive discharging rate for any battery Oil and grease Dust, powders, liquids and gases Equipment in intended use not considered to be exposed to these Containers for liquids or gases Flammable liquids... : No flammable liquids in this unit. Quantity of liquid (l)... : Flash point (C)... : Radiation No ionizing radiation, laser or flammable gases presents General Ionizing radiation Measured radiation (pa/kg)... : Measured high-voltage (kv)... : Measured focus voltage (kv)... : CRT markings... : Effect of ultraviolet (UV) radiation on materials No UV radiation. Part, property, retention after test, flammability classification... : Human exposure to ultraviolet (UV) radiation... : No UV radiation Lasers (including laser diodes) and LEDs No laser and LEDs provided Lasers (including laser diodes) Laser class... : Light emitting diodes (LEDs) Other types... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 24 of 41 Test Report IEC60950_1B

29 IEC/EN Protection against hazardous moving parts General No moving parts Protection in operator access areas... : No moving parts. Household and home/office document/media shredders Protection in restricted access locations... : Equipment is not intended to be used in restricted locations Protection in service access areas No moving parts Protection against moving fan blades No moving fan General Not considered to cause pain or injury. a).: Is considered to cause pain, not injury. b) : Considered to cause injury. c) : Protection for users Use of symbol or warning : Protection for service persons Use of symbol or warning : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 25 of 41 Test Report IEC60950_1B

30 IEC/EN Thermal requirements General This webcam is very low power consumption; no temperature testing was carried out as part of this assessment Temperature tests Normal load condition per Annex L... : Temperature limits for materials Touch temperature limits Resistance to abnormal heat... : Only SELV circuit. 4.6 Openings in enclosures P Top and side openings No opening. P Dimensions (mm)... : Bottoms of fire enclosures No opening. P Construction of the bottomm, dimensions (mm). : Doors or covers in fire enclosures No door or cover Openings in transportable equipment Not applied for Constructional design measures Dimensions (mm)... : Evaluation measures for larger openings Use of metallized parts Adhesives for constructional purposes Conditioning temperature (C), time (weeks)... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 26 of 41 Test Report IEC60950_1B

31 IEC/EN Resistance to fire P Reducing the risk of ignition and spread of flame Use of materials with the required flammability classes. Method 1, selection and application of components wiring and materials Method 2, application of all of simulated fault condition tests Selection and application of components and materials which minimize the possibility of ignition and spread of flame Conditions for a fire enclosure See below. P Parts requiring a fire enclosure See Parts not requiring a fire enclosure The components mounted on V-1 PWB and unit power source is considered supplied by limited power sources Materials P General See below. P Materials for fire enclosures Plastic enclosure material is rated min. HB. (Refer to and , fire enclosure is not required) Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures No components or parts outside fire enclosures. Internal components except small parts are V-2, HF-2 or better. Internal printed wiring board min. rated V Materials for air filter assemblies No air filters assemblies Materials used in high-voltage components No high voltage component used. P P P P P 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 27 of 41 Test Report IEC60950_1B

32 IEC/EN ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS P 5.1 Touch current and protective conductor current General Configuration of equipment under test (EUT) Single connection to an a.c. mains supply Redundant multiple connections to an a.c. mains supply Simultaneous multiple connections to an a.c. mains supply Test circuit Application of measuring instrument Test procedure Test measurements Supply voltage (V)... : Measured touch current (ma)... : Max. allowed touch current (ma)... : Measured protective conductor current (ma)... : Max. allowed protective conductor current (ma).. : Equipment with touch current exceeding 3,5 ma General... : Simultaneous multiple connections to the supply Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network or to a cable distribution system Supply voltage (V)... : Measured touch current (ma)... : Max. allowed touch current (ma)... : Summation of touch currents from telecommunication networks a) EUT with earthed telecommunication ports... : b) EUT whose telecommunication ports have no reference to protective earth 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 28 of 41 Test Report IEC60950_1B

33 IEC/EN Electric strength General Class III equipment, supplied by SELV and not directly connected to the mains Test procedure 5.3 Abnormal operating and fault conditions P Protection against overload and abnormal operation Not apply for Motors No motor provided Transformers No safety isolation transformer used Functional insulation...: Only SELV circuit provided with the equipment Electromechanical components No such components Audio amplifiers in ITE...: No audio amplifiers inside equipment Simulation of faults Unattended equipment None of them are used Compliance criteria for abnormal operating and fault conditions During the tests After the tests P 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 29 of 41 Test Report IEC60950_1B

34 IEC/EN CONNECTION TO TELECOMMUNICATION NETWORKS 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment Protection from hazardous voltages Separation of the telecommunication network from earth Requirements Not direct connection to TELECOMMUNICATION NETWORK. Supply voltage (V)... : Current in the test circuit (ma)... : Exclusions... : 6.2 Protection of equipment users from overvoltages on telecommunication networks Separation requirements Electric strength test procedure Impulse test Steady-state test Compliance criteria 6.3 Protection of the telecommunication wiring system from overheating Max. output current (A)... : Current limiting method... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 30 of 41 Test Report IEC60950_1B

35 IEC/EN CONNECTION TO CABLE DISTRIBUTION SYSTEMS 7.1 General Not direct connection to cable distribution system. 7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment 7.3 Protection of equipment users from overvoltages on the cable distribution system 7.4 Insulation between primary circuits and cable distribution systems General Voltage surge test Impulse test 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 31 of 41 Test Report IEC60950_1B

36 IEC/EN A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see ) A.1.1 Samples... : Wall thickness (mm)... : A.1.2 Conditioning of samples; temperature (C)... : A.1.3 Mounting of samples... : A.1.4 Test flame (see IEC ) Flame A, B, C or D... : A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material... : Wall thickness (mm)... : A.2.2 Conditioning of samples; temperature ( C)... : A.2.3 Mounting of samples... : A.2.4 Test flame (see IEC ) Flame A, B or C... : A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.2.7 Alternative test acc. to IEC , cl. 5 and 9 Sample 1 burning time (s)... : Sample 2 burning time (s)... : Sample 3 burning time (s)... : A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 32 of 41 Test Report IEC60950_1B

37 IEC/EN B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS (see and 5.3.2) B.1 General requirements Position... : Manufacturer... : Type... : Rated values... : B.2 Test conditions B.3 Maximum temperatures B.4 Running overload test B.5 Locked-rotor overload test Test duration (days)... : Electric strength test: test voltage (V)... : B.6 Running overload test for d.c. motors in secondary circuits B.6.1 General B.6.2 Test procedure B.6.3 Alternative test procedure B.6.4 Electric strength test; test voltage (V)... : B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 General B.7.2 Test procedure B.7.3 Alternative test procedure B.7.4 Electric strength test; test voltage (V)... : B.8 Test for motors with capacitors B.9 Test for three-phase motors B.10 Test for series motors Operating voltage (V)... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 33 of 41 Test Report IEC60950_1B

38 IEC/EN C ANNEX C, TRANSFORMERS (see and 5.3.3) Position... : Manufacturer... : Type... : Rated values... : Method of protection... : No safety isolation transformer inside the equipment. C.1 Overload test C.2 Insulation Protection from displacement of windings... : D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) D.1 Measuring instrument D.2 Alternative measuring instrument E ANNEX E, TEMPERATURE RISE OF A WINDING (see ) F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G) 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 34 of 41 Test Report IEC60950_1B

39 IEC/EN G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES G.1 Clearances G.1.1 General G.1.2 Summary of the procedure for determining minimum clearances G.2 Determination of mains transient voltage (V) G.2.1 AC mains supply... : G.2.2 Earthed d.c. mains supplies... : G.2.3 Unearthed d.c. mains supplies... : G.2.4 Battery operation... : G.3 Determination of telecommunication network transient voltage (V)... : G.4 Determination of required withstand voltage (V) G.4.1 Mains transients and internal repetitive peaks... : G.4.2 Transients from telecommunication networks... : G.4.3 Combination of transients G.4.4 Transients from cable distribution systems G.5 Measurement of transient voltages (V) a) Transients from a mains supply For an a.c. mains supply For a d.c. mains supply b) Transients from a telecommunication network G.6 Determination of minimum clearances... : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 35 of 41 Test Report IEC60950_1B

40 IEC/EN H ANNEX H, IONIZING RADIATION (see ) J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see ) Metal(s) used... : K ANNEX K, THERMAL CONTROLS (see and 5.3.8) K.1 Making and breaking capacity K.2 Thermostat reliability; operating voltage (V)... : K.3 Thermostat endurance test; operating voltage (V)... : K.4 Temperature limiter endurance; operating voltage (V)... : K.5 Thermal cut-out reliability K.6 Stability of operation L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see and 4.5.2) L.1 Typewriters L.2 Adding machines and cash registers L.3 Erasers L.4 Pencil sharpeners L.5 Duplicators and copy machines L.6 Motor-operated files L.7 Other business equipment 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 36 of 41 Test Report IEC60950_1B

41 IEC/EN M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) M.1 Introduction M.2 Method A M.3 Method B M.3.1 Ringing signal M Frequency (Hz)... : M Voltage (V)... : M Cadence; time (s), voltage (V)... : M Single fault current (ma)... : M.3.2 Tripping device and monitoring voltage... : M Conditions for use of a tripping device or a monitoring voltage M Tripping device M Monitoring voltage (V)... : N ANNEX N, IMPULSE TEST GENERATORS (see , , , , 7.3.2, and Clause G.5) N.1 ITU-T impulse test generators N.2 IEC impulse test generator P ANNEX P, NORMATIVE REFERENCES Q ANNEX Q, Voltage dependent resistors (VDRs) (see ) a) Preferred climatic categories... : b) Maximum continuous voltage... : c) Pulse current... : R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 37 of 41 Test Report IEC60950_1B

42 IEC/EN T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2) U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see ) V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) V.1 Introduction V.2 TN power distribution systems W ANNEX W, SUMMATION OF TOUCH CURRENTS W.1 Touch current from electronic circuits W.1.1 Floating circuits W.1.2 Earthed circuits W.2 Interconnection of several equipments W.2.1 Isolation W.2.2 Common return, isolated from earth W.2.3 Common return, connected to protective earth X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) X.1 Determination of maximum input current X.2 Overload test procedure Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see ) Y.1 Test apparatus... : Y.2 Mounting of test samples... : Y.3 Carbon-arc light-exposure apparatus... : Y.4 Xenon-arc light exposure apparatus... : Z ANNEX Z, OVERVOLTAGE CATEGORIES (see and Clause G.2) 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 38 of 41 Test Report IEC60950_1B

43 IEC/EN AA ANNEX AA, MANDREL TEST (see ) BB ANNEX BB, CHANGES IN THE SECOND EDITION CC ANNEX CC, Evaluation of integrated circuit (IC) current limiters CC.1 General No such construction. CC.2 Test program 1.: CC.3 Test program 2.: DD ANNEX DD, Requirements for the mounting means of rack-mounted equipment DD.1 General No such construction. DD.2 DD.3 Mechanical strength test, variable N..: Mechanical strength test, 250N, including end stops : DD.4 Compliance : EE ANNEX EE, Household and home/office document/media shredders EE.1 General This equipment is not a document (paper) shredder. EE.2 Markings and instructions EE.3 EE.4 Use of markings or symbols : Information of user instructions, maintenance and/or servicing instructions : Inadvertent reactivation test : Disconnection of power to hazardous moving parts: Use of markings or symbols : EE.5 Protection against hazardous moving parts Test with test finger (Figure 2A) : Test with wedge probe (Figure EE1 and EE2) : 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 39 of 41 Test Report IEC60950_1B

44 1.5.1 TABLE: List of critical components P Object/part No. Manufacturer/ trademark Type/model Technical data Standard (Edition / year) Enclosure Various Various HB min., overall 28.8 mm by 24.4 mm by 94.1 mm. (without base) Base Various Various HB min., overall 111 mm by 45.8 mm by 24.6 mm max. UL 94, UL 746C UL 94, UL 746C PCB Various Various V-1 min., 105 C UL 796 UL 1 ) an asterisk indicates a mark which assures the agreed level of surveillance Supplementary information: Mark(s) of conformity 1 ) UL UL 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 40 of 41 Test Report IEC60950_1B

45 1.6.2 TABLE: Electrical data (in normal conditions) P U (Vdc) I (ma) Irated (ma) P (W) Fuse # Ifuse (A) Condition/status Maximum normal load Supplementary information: 7F., No. 37, Sec. 2, Zhongyang S. Rd., V-U0028.DOC Beitou District, Taipei City, 11270, Taiwan Page 41 of 41 Test Report IEC60950_1B

46 Attachment No. 1 National and Group Differences for IEC nd Ed. as per CB Bulletin and EN : A11: A1: A12:2011 Countries Included: See overview on following page Attachment contains Cover page: National Differences: Total: 1 page 52 pages 53 pages Explanation for Abbreviations: Possible Verdicts: P = Pass, F= Fail, = Not Applicable Remarks: Throughout this report, a point is used as the decimal separator. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev. No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 1 of 53 National Differences IEC nd ed. + A1:2009

47 IEC60950_1B - ATTACHMENT ATTACHMENT TO TEST REPORT IEC EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES Information technology equipment Safety Differences according to... : Attachment Form No.... : Attachment Originator... : Part 1: General requirements EN :2006/A11:2009/A1:2010/A12:2011 EU_GD_IEC60950_1B_II SGS Fimko Ltd Master Attachment... : Date Copyright 2011 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. EN :2006/A11:2009/A1:2010/A12:2011 CENELEC COMMON MODIFICATIONS IEC , GROUP DIFFERENCES (CENELEC common modifications EN) Contents Add the following annexes: Annex ZA (normative) Normative references to international publications with their corresponding European publications P Annex ZB (normative) Special national conditions General Delete all the country notes in the reference document (IEC :2005) according to the following list: P Note Note 2 & Note Note Note Note 4, 5 & Note Note Note Note Note Note 2 & Note Note Note Note Note Note Note 1 & Note Note Note Note 3 & Note Note 2 & Note Note Note Note Note 7.1 Note Note 7.3 Note 1 & 2 G.2.1 Note 2 Annex H Note 2 General (A1:2010) Delete all the country notes in the reference document (IEC :2005/A1:2010) according to the following list: P Note Note Note 2 EE.3 Note TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 2 of 53 National Differences IEC nd ed. + A1:2009

48 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) 1.3.Z1 (A12:2011) Add the following subclause: 1.3.Z1 Exposure to excessive sound pressure The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose, either in normal operating conditions or under fault conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones. NOTE Z1 A new method of measurement is described in EN , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 1: General method for one package equipment, and in EN , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 2: Guidelines to associate sets with headphones coming from different manufacturers. In EN :2006/A12:2011 Delete the addition of 1.3.Z1 / EN :2006 Delete the definition Z1 / EN :2006 /A1: Add the following NOTE: (A1:2010) (A ) NOTE Z1 The use of certain substances in electrical and electronic equipment is restricted within the EU: see Directive 2002/95/EC In addition, for a PORTABLE SOUND SYSTEM, the instructions shall include a warning that excessive sound pressure from earphones and headphones can cause hearing loss. In EN :2006/A12:2011 Delete NOTE Z1 and the addition for Portable Sound System. Add the following clause and annex to the existing standard and amendments. The equipment is not a PORTABLE SOUND SYSTEM. Deleted. Not applicable. The equipment is not a PORTABLE SOUND SYSTEM. Not applicable. Zx Protection against excessive sound pressure from personal music players P TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 3 of 53 National Differences IEC nd ed. + A1:2009

49 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) Zx.1 General Not applicable. This sub-clause specifies requirements for protection against excessive sound pressure from personal music players that are closely coupled to the ear. It also specifies requirements for earphones and headphones intended for use with personal music players. A personal music player is a portable equipment for personal use, that: is designed to allow the user to listen to recorded or broadcast sound or video; and primarily uses headphones or earphones that can be worn in or on or around the ears; and allows the user to walk around while in use. NOTE 1 Examples are hand-held or body-worn portable CD players, MP3 audio players, mobile phones with MP3 type features, PDA s or similar equipment. A personal music player and earphones or headphones intended to be used with personal music players shall comply with the requirements of this sub-clause. The requirements in this sub-clause are valid for music or video mode only. The requirements do not apply: while the personal music player is connected to an external amplifier; or while the headphones or earphones are not used. NOTE 2 An external amplifier is an amplifier which is not part of the personal music player or the listening device, but which is intended to play the music as a standalone music player. The requirements do not apply to: hearing aid equipment and professional equipment; NOTE 3 Professional equipment is equipment sold through special sales channels. All products sold through normal electronics stores are considered not to be professional equipment. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 4 of 53 National Differences IEC nd ed. + A1:2009

50 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) analogue personal music players (personal music players without any kind of digital processing of the sound signal) that are brought to the market before the end of NOTE 4 This exemption has been allowed because this technology is falling out of use and it is expected that within a few years it will no longer exist. This exemption will not be extended to other technologies. Not applicable. For equipment which is clearly designed or intended for use by young children, the limits of EN 71-1 apply. Zx.2 Equipment requirements No safety provision is required for equipment that complies with the following: equipment provided as a package (personal music player with its listening device), where the acoustic output LAeq,T is 85 dba measured while playing the fixed programme simulation noise as described in EN ; and a personal music player provided with an analogue electrical output socket for a listening device, where the electrical output is 27 mv measured as described in EN , while playing the fixed programme simulation noise as described in EN NOTE 1 Wherever the term acoustic output is used in this clause, the 30 s A-weighted equivalent sound pressure level LAeq,T is meant. See also Zx.5 and Annex Zx. Not applicable. All other equipment shall: a) protect the user from unintentional acoustic outputs exceeding those mentioned above; and b) have a standard acoustic output level not exceeding those mentioned above, and automatically return to an output level not exceeding those mentioned above when the power is switched off; and TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 5 of 53 National Differences IEC nd ed. + A1:2009

51 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) c) provide a means to actively inform the user of the increased sound pressure when the equipment is operated with an acoustic output exceeding those mentioned above. Any means used shall be acknowledged by the user before activating a mode of operation which allows for an acoustic output exceeding those mentioned above. The acknowledgement does not need to be repeated more than once every 20 h of cumulative listening time; and NOTE 2 Examples of means include visual or audible signals. Action from the user is always required. NOTE 3 The 20 h listening time is the accumulative listening time, independent how often and how long the personal music player has been switched off. d) have a warning as specified in Zx.3; and e) not exceed the following: 1) equipment provided as a package (player with Its listening device), the acoustic output shall be 100 dba measured while playing the fixed programme simulation noise described in EN ; and 2) a personal music player provided with an analogue electrical output socket for a listening device, the electrical output shall be 150 mv measured as described in EN , while playing the fixed programme simulation noise described in EN For music where the average sound pressure (long term LAeq,T) measured over the duration of the song is lower than the average produced by the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dba. In this case T becomes the duration of the song. NOTE 4 Classical music typically has an average sound pressure (long term LAeq,T) which is much lower than the average programme simulation noise. Therefore, if the player is capable to analyse the song and compare it with the programme simulation noise, the warning does not need to be given as long as the average sound pressure of the song is below the basic limit of 85 dba. For example, if the player is set with the programme simulation noise to 85 dba, but the average music level of the song is only 65 dba, there is no need to give a warning or ask an acknowledgement as long as the average sound level of the song is not above the basic limit of 85 dba. Not applicable. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 6 of 53 National Differences IEC nd ed. + A1:2009

52 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) Zx.3 Warning The warning shall be placed on the equipment, or on the packaging, or in the instruction manual and shall consist of the following: the symbol of Figure 1 with a minimum height of 5 mm; and the following wording, or similar: Not applicable. To prevent possible hearing damage, do not listen at high volume levels for long periods. Figure 1 Warning label (IEC ) Alternatively, the entire warning may be given through the equipment display during use, when the user is asked to acknowledge activation of the higher level. Zx.4 Requirements for listening devices (headphones and earphones) Zx.4.1 Wired listening devices with analogue input With 94 dba sound pressure output LAeq,T, the input voltage of the fixed programme simulation noise described in EN shall be 75 mv. Not applicable. This requirement is applicable in any mode where the headphones can operate (active or passive), including any available setting (for example built-in volume level control). NOTE The values of 94 dba 75 mv correspond with 85dBA 27 mv and 100 dba 150 mv. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 7 of 53 National Differences IEC nd ed. + A1:2009

53 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) Zx.4.2 Wired listening devices with digital input With any playing device playing the fixed programme simulation noise described in EN (and respecting the digital interface standards, where a digital interface standard exists that specifies the equivalent acoustic level), the acoustic output LAeq,T of the listening device shall be 100 dba. Not applicable. This requirement is applicable in any mode where the headphones can operate, including any available setting (for example built-in volume level control, additional sound feature like equalization, etc.). NOTE An example of a wired listening device with digital input is a USB headphone. Zx.4.3 Wireless listening devices In wireless mode: with any playing and transmitting device playing the fixed programme simulation noise described in EN ; and respecting the wireless transmission standards, where an air interface standard exists that specifies the equivalent acoustic level; and with volume and sound settings in the listening device (for example built-in volume level control, additional sound feature like equalization, etc.) set to the combination of positions that maximize the measured acoustic output for the abovementioned programme simulation noise, the acoustic output LAeq,T of the listening device shall be 100 dba. Not applicable. NOTE An example of a wireless listening device is a Bluetooth headphone. Zx.5 Measurement methods Measurements shall be made in accordance with EN or EN as applicable. Unless stated otherwise, the time interval T shall be 30 s. Not applicable. NOTE Test method for wireless equipment provided without listening device should be defined. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 8 of 53 National Differences IEC nd ed. + A1:2009

54 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) Replace the subclause as follows: Basic requirements To protect against excessive current, shortcircuits and earth faults in PRIMARY CIRCUITS, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, shortcircuit and earth fault protection may be provided by protective devices in the building installation; c) it is permitted for PLUGGABLE EQUIPMENT TYPE B or PERMANENTLY CONNECTED EQUIPMENT, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for PLUGGABLE EQUIPMENT TYPE A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet This subclause has been declared void Delete the NOTE in Table 3A, and delete also in this table the conduit sizes in parentheses Replace IEC 53 by H05 RR-F ; IEC 52 by H03 VV-F or H03 VVH2-F ; IEC 53 by H05 VV-F or H05 VVH2-F2. In Table 3B, replace the first four lines by the following: Up to and including 6 0,75 a) Over 6 up to and including 10 (0,75) b) 1,0 Over 10 up to and including 16 (1,0) c) 1,5 In the conditions applicable to Table 3B delete the words in some countries in condition a). In NOTE 1, applicable to Table 3B, delete the second sentence. Not permanently connected equipment. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 9 of 53 National Differences IEC nd ed. + A1:2009

55 IEC60950_1B - ATTACHMENT IEC , GROUP DIFFERENCES (CENELEC common modifications EN) In Table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following: Over 10 up to and including 16 1,5 to 2,5 1,5 to 4 Delete the fifth line: conductor sizes for 13 to 16 A (A1:2010) Annex H Replace the existing NOTE by the following: NOTE Z1 Attention is drawn to: 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz, and 2006/25/EC: Directive on the minimum health and safety requirements regarding the exposure of workers to risks arising from physical agents (artifical optical radiation). Standards taking into account mentioned Recommendation and Directive which demonstrate compliance with the applicable EU Directive are indicated in the OJEC. Replace the last paragraph of this annex by: At any point 10 cm from the surface of the OPERATOR ACCESS AREA, the dose rate shall not exceed 1 μsv/h (0,1 mr/h) (see NOTE). Account is taken of the background level. Replace the notes as follows: NOTE These values appear in Directive 96/29/Euratom. Delete NOTE 2. The equipment does not generate ionizing radiation or uses a laser. Ditto. The unit does not emit X-ray radiation. Bibliography Additional EN standards. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 10 of 53 National Differences IEC nd ed. + A1:2009

56 IEC60950_1B - ATTACHMENT ZA NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR CORRESPONDING EUROPEAN PUBLICATIONS ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) In Denmark, certain types of Class I appliances (see ) may be provided with a plug not establishing earthing conditions when inserted into Danish socket-outlets In Norway and Sweden, for requirements see and 7.3 of this annex In Finland, Norway and Sweden, resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in In addition when a single resistor is used, the resistor must withstand the resistor test in In Norway, due to the IT power system used (see annex V, Figure V.7), capacitors are required to be rated for the applicable line-to-line voltage (230 V) In Finland, Norway and Sweden, the third dashed sentence is applicable only to equipment as defined in of this annex. No TNV and cable distribution system in the equipment. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 11 of 53 National Differences IEC nd ed. + A1:2009

57 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text in the applicable countries shall be as follows: In Finland: "Laite on liitettävä suojakoskettimilla varustettuun pistorasiaan" In Norway: Apparatet må tilkoples jordet stikkontakt In Sweden: Apparaten skall anslutas till jordat uttag In Norway and Sweden, the screen of the cable distribution system is normally not earthed at the entrance of the building and there is normally no equipotential bonding system within the building. Therefore the protective earthing of the building installation need to be isolated from the screen of a cable distribution system. It is however accepted to provide the insulation external to the equipment by an adapter or an interconnection cable with galvanic isolator, which may be provided by e.g. a retailer. The user manual shall then have the following or similar information in Norwegian and Swedish language respectively, depending on in what country the equipment is intended to be used in: Equipment connected to the protective earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing and to a cable distribution system using coaxial cable, may in some circumstances create a fire hazard. Connection to a cable distribution system has therefore to be provided through a device providing electrical isolation below a certain frequency range (galvanic isolator, see EN ). TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 12 of 53 National Differences IEC nd ed. + A1:2009

58 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) NOTE In Norway, due to regulation for installations of cable distribution systems, and in Sweden, a galvanic isolator shall provide electrical insulation below 5 MHz. The insulation shall withstand a dielectric strength of 1,5 kv r.m.s., 50 Hz or 60 Hz, for 1 min. Translation to Norwegian (the Swedish text will also be accepted in Norway): Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr og er tilkoplet et kabel-tv nett, kan forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-tv nettet installeres en galvanisk isolator mellom utstyret og kabel- TV nettet. Translation to Swedish: Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt är kopplad till kabel-tv nät kan i vissa fall medfőra risk főr brand. Főr att undvika detta skall vid anslutning av utrustningen till kabel-tv nät galvanisk isolator finnas mellan utrustningen och kabel-tv nätet In Denmark, socket-outlets for providing power to other equipment shall be in accordance with the Heavy Current Regulations, Section D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard Sheet DK 1-1b or DK 1-5a. For CLASS II EQUIPMENT the socket outlet shall be in accordance with Standard Sheet DKA 1-4a In Norway, for requirements see , and of this annex In Finland, Norway and Sweden there are additional requirements for the insulation. See and of this annex In Norway, for requirements see , and of this annex In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not 16 A. No TNV circuits. No TNV circuits. No TNV circuits. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 13 of 53 National Differences IEC nd ed. + A1:2009

59 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) In the United Kingdom, to protect against excessive currents and short-circuits in the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 shall be conducted, using an external protective device rated 30 A or 32 A. If these tests fail, suitable protective devices shall be included as integral parts of the DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met. No direct plug-in equipment In Finland, Norway and Sweden, there are additional requirements for the insulation, see and of this annex In Switzerland, supply cords of equipment having a RATED CURRENT not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC and one of the following dimension sheets: SEV Plug Type 15 3P+N+PE 250/400 V, 10 A SEV Plug Type 11 L+N 250 V, 10 A SEV Plug Type 12 L+N+PE 250 V, 10 A In general, EN applies for plugs for currents exceeding 10 A. However, a 16 A plug and socket-outlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998: SEV : Plug Type 25, 3L+N+PE 230/400 V, 16 A SEV :Plug Type 21, L+N, 250 V, 16A SEV : Plug Type 23, L+N+PE 250 V, 16 A TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 14 of 53 National Differences IEC nd ed. + A1:2009

60 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) In Denmark, supply cords of single-phase equipment having a rated current not exceeding13 A shall be provided with a plug according to the Heavy Current Regulations, Section D1. CLASS I EQUIPMENT provided with socketoutlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If poly-phase equipment and single-phase equipment having a RATED CURRENT exceeding 13 A is provided with a supply cord with a plug, this plug shall be in accordance with the Heavy Current Regulations, Section D1 or EN In Spain, supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315:1994. Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UNE-EN 50075:1993. CLASS I EQUIPMENT provided with socketoutlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UNE 20315:1994. If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UNE-EN TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 15 of 53 National Differences IEC nd ed. + A1:2009

61 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) In the United Kingdom, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a standard plug in accordance with Statutory Instrument 1768: The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations. NOTE Standard plug is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug In Ireland, apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525: National Standards Authority of Ireland (section 28) (13 A Plugs and Conversion Adaptors for Domestic Use) Regulations In Switzerland, for requirements see of this annex In the United Kingdom, a power supply cord with conductor of 1,25 mm2 is allowed for equipment with a rated current over 10 A and up to and including 13 A In the United Kingdom, the range of conductor sizes of flexible cords to be accepted by terminals for equipment with a RATED CURRENT of over 10 A up to and including 13 A is: 1,25 mm 2 to 1,5 mm 2 nominal cross-sectional area In the United Kingdom, the torque test is performed using a socket outlet complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, and 12.17, except that the test of is performed at not less than 125 C. Where the metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the requirements of clauses 22.2 and 23 also apply. No direct plug-in equipment. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 16 of 53 National Differences IEC nd ed. + A1:2009

62 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) In Ireland, DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such devices shall comply with Statutory Instrument 526: National Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, No direct plug-in equipment In Finland, Norway and Sweden TOUCH CURRENT measurement results exceeding 3,5 ma r.m.s. are permitted only for the following equipment: STATIONARY PLUGGABLE EQUIPMENT TYPE A that is intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, for example, in a telecommunication centre; and has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR; and is provided with instructions for the installation of that conductor by a SERVICE PERSON; STATIONARY PLUGGABLE EQUIPMENT TYPE B; STATIONARY PERMANENTLY CONNECTED EQUIPMENT. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 17 of 53 National Differences IEC nd ed. + A1:2009

63 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) In Finland, Norway and Sweden, add the No TNV circuits. following text between the first and second (A1:2010) paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. Alternatively for components, there is no distance through insulation requirements for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 18 of 53 National Differences IEC nd ed. + A1:2009

64 IEC60950_1B - ATTACHMENT ZB ANNEX (normative) SPECIAL NATIONAL CONDITIONS (EN) It is permitted to bridge this insulation with an optocoupler complying with b). No TNV circuits. It is permitted to bridge this insulation with a capacitor complying with EN :2005, subclass Y2. A capacitor classified Y3 according to EN :2005, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN :2006, ; - the additional testing shall be performed on all the test specimens as described in EN : - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN In Finland, Norway and Sweden, the exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT, PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a SERVICE PERSON. 7.2 In Finland, Norway and Sweden, for requirements see and of this annex. The term TELECOMMUNICATION NETWORK in being replaced by the term CABLE DISTRIBUTION SYSTEM. 7.3 In Norway and Sweden, for requirements see and of this annex. 7.3 In Norway, for installation conditions see EN :2005. No TNV circuits. Not intended to be connected to cable distribution system. Not intended to be connected to cable distribution system. Not intended to be connected to cable distribution system. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 19 of 53 National Differences IEC nd ed. + A1:2009

65 IEC60950_1B - ATTACHMENT ATTACHMENT TO TEST REPORT IEC NATIONAL DIFFERENCES Information technology equipment Safety Part 1: General requirements Australia (AU) National standard reference.: AS/NZS ZZ1 ZZ2 INTRODUCTION This Appendix sets out variations and additional requirements to cover issues which have not been addressed by the International Standard. These variations indicate national variations for purposes of the IECEE CB System and will be published in the IECEE CB Bulletin. VARIATIONS The following variations apply to the source text. 1.2 Insert the following between person, service and range, rated frequency : POTENTIAL IGNITION SOURCE Insert a new Clause after Clause as follows: POTENTIAL IGNITION SOURCE Possible fault which can start a fire if the opencircuit voltage measured across an interruption or faulty contact exceeds a value of 50 V (peak) a.c. or d.c. and the product of the peak value of this voltage and the measured r.m.s. current under normal operating conditions exceeds 15 VA. Such a faulty contact or interruption in an electrical connection includes those which may occur in CONDUCTIVE PATTERNS on PRINTED BOARDS. NOTE 201 An electronic protection circuit may be used to prevent such a fault from becoming a POTENTIAL IGNITION SOURCE. NOTE 202 This definition is from AS/NZS 60065:2003. Not considered. Ditto. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 20 of 53 National Differences IEC nd ed. + A1:2009

66 IEC60950_1B - ATTACHMENT Add the following to the end of the first paragraph: `or the relevant Australian/New Zealand Standard. 2. In NOTE 1, add the following after the word standard : `or an Australian/New Zealand Standard Add the following to the end of the first and third dash items: `or the relevant Australian/New Zealand Standard Modify Table 3B as follows: 1. Delete the first four rows and replace with the following: RATED CURRENT of equipment A Over 0.2 up to and including 3 Over 3 up to and including 7.5 Over 7.5 up to and including 10 Over 10 up to and including 16 Minimum conductor sizes Nominal crosssectional area mm 2 0,5 a 0,75 (0,75) b 1,00 (1,0) c 1,5 AWG or kcmil [crosssectional area in mm 2 ] See note 2 18 [0,8] 16 [1,3] 16 [1,3] 14 [2] Added. Added. 2. Delete NOTE Delete Footnote a and replace with the following: a This nominal cross-sectional area is only allowed for Class II appliances if the length of the power supply cord, measured between the point where the cord, or cord guard, enters the appliance, and the entry to the plug does not exceed 2 m (0,5 mm 2 threecore supply flexible cords are not permitted; see AS/NZS 3191). TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 21 of 53 National Differences IEC nd ed. + A1:2009

67 IEC60950_1B - ATTACHMENT Insert a new Clause after Clause 4.1 as follows: Display devices used for television purposes Display devices which may be used for television purposes, with a mass of 7 kg or more, shall comply with the requirements for stability and mechanical hazards, including the additional stability requirements for television receivers, specified in AS/NZS Delete the third paragraph and replace with the following: Equipment with a plug portion, suitable for insertion into a 10 A 3-pin flatpin socket-outlet complying with AS/NZS 3112 shall comply with the requirements in AS/NZS 3112 for equipment with integral pins for insertion into socket-outlets Add the following to the end of the first paragraph:, or AS/NZS Add the following new paragraph to the end of the clause: For alternate tests refer to Clause No display devices. Unit is not DIRECT PLUG-IN EQUIPMENT. Added the paragraph. Refer to below. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 22 of 53 National Differences IEC nd ed. + A1:2009

68 IEC60950_1B - ATTACHMENT Insert a new Clause after Clause as follows: Resistance to fire Alternative tests General Parts of non-metallic material shall be resistant to ignition and spread of fire. This requirement does not apply to decorative trims, knobs and other parts unlikely to be ignited or to propagate flames from inside the apparatus, or the following: a) Components that are contained in an enclosure having a flammability category of V-0 according to AS/NZS and having openings only for the connecting wires filling the openings completely, and for ventilation not exceeding 1mm in width regardless of length. b) The following parts which would contribute negligible fuel to a fire: - small mechanical parts, the mass of which does not exceed 4g, such as mounting parts, gears, cams, belts and bearings; - small electrical components, such as capacitors with a volume not exceeding 1,750 mm 3, integrated circuits, transistors and optocoupler packages, if these components are mounted on material of flammability category V-1, or better, according to AS/NZS NOTE In considering how to minimize propagation of fire and what small parts are, account should be taken of the cumulative effect of small parts adjacent to each other for the possible effect of propagating the fire from one part to another. Not apply for; materials have suitable flame class including fire enclosure. Compliance shall be checked by the tests of , , and For the base material of printed boards, compliance shall be checked by the test of TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 23 of 53 National Differences IEC nd ed. + A1:2009

69 IEC60950_1B - ATTACHMENT The tests shall be carried out on parts of nonmetallic material which have been removed from the apparatus. When the glow-wire test is carried out, the parts shall be placed in the same orientation as they would be in normal use. These tests are not carried out on internal wiring Testing of non-metallic materials Ditto. Parts of non-metallic material shall be subject to the glow-wire test of AS/NZS which shall be carried out at 550 C. Parts for which the glow-wire test cannot be carried out, such as those made of soft or foamy material, shall meet the requirements specified in ISO 9772 for category FH-3 material. The glowwire test shall be not carried out on parts of material classified at least FH-3 according to ISO 9772 provided that the sample tested was not thicker than the relevant part Testing of insulating materials Parts of insulating material supporting POTENTIAL IGNITION SOURCES shall be subject to the glow-wire test of AS/NZS which shall be carried out at 750 C. The test shall be also carried out on other parts of insulating material which are within a distance of 3 mm of the connection. NOTE Contacts in components such as switch contacts are considered to be connections. For parts which withstand the glow-wire test but produce a flame, other parts above the connection within the envelope of a vertical cylinder having a diameter of 20 mm and a height of 50 mm shall be subjected to the needleflame test. However, parts shielded by a barrier which meets the needle-flame test shall not be tested. The needle-flame test shall be made in accordance with AS/NZS with the following modifications: Not apply for; materials have suitable flame class including fire enclosure. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 24 of 53 National Differences IEC nd ed. + A1:2009

70 IEC60950_1B - ATTACHMENT Clause of AS/NZS Test procedure 9.2 Application of needle-flame 9.3 Number of test specimens 11 Evaluation of test results Replace the first paragraph with: The specimen shall be arranged so that the flame can be applied to a vertical or horizontal edge as shown in the examples of figure 1. If possible the flame shall be applied at least 10 mm from a corner Replace the second paragraph with: The duration of application of the test flame shall be 30s±1s. Replace with: The test shall be made on one specimen. If the specimen does not withstand the test, the test may be repeated on two further specimens, both of which shall withstand the test. Replace with: The duration of burning (tb) shall not exceed 30 s. However, for printed circuit boards, it shall not exceed 15s. Ditto. The needle-flame test shall not be carried out on parts of material classified as V-0 or V-1 according to AS/NZS , provided that the sample tested was not thicker than the relevant part. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 25 of 53 National Differences IEC nd ed. + A1:2009

71 IEC60950_1B - ATTACHMENT Testing in the event of nonextinguishing material If parts, other than enclosures, do not withstand the glow wire tests of , by failure to extinguish within 30 s after the removal of the glow-wire tip, the needle-flame test detailed in shall be made on all parts of nonmetallic material which are within a distance of 50 mm or which are likely to be impinged upon by flame during the tests of Parts shielded by a separate barrier which meets the needle-flame test need not be tested. NOTE 1 If the enclosure does not withstand the glow-wire test the equipment is considered to have failed to meet the requirements of Clause without the need for consequential testing. NOTE 2 If other parts do not withstand the glowwire test due to ignition of the tissue paper and if this indicates that burning or glowing particles can fall onto an external surface underneath the equipment, the equipment is considered to have failed to meet the requirements of Clause without the need for consequential testing. NOTE 3 Parts likely to be impinged upon by the flame are considered to be those within the envelope of a vertical cylinder having a radius of 10 mm and a height equal to the height of the flame, positioned above the point of the material supporting, in contact with, or in close proximity to, connections. Not apply for; materials have suitable flame class including fire enclosure. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 26 of 53 National Differences IEC nd ed. + A1:2009

72 IEC60950_1B - ATTACHMENT Testing of printed boards The base material of printed boards shall be subjected to the needle-flame test of Clause The flame shall be applied to the edge of the board where the heat sink effect is lowest when the board is positioned as in normal use. The flame shall not be applied to an edge, consisting of broken perforations, unless the edge is less than 3 mm from a POTENTIAL IGNITION SOURCE. The test is not carried out if the - Printed board does not carry any POTENTIAL IGNITION SOURCE; - Base material of printed boards, on which the available apparent power at a connection exceeds 15 VA operating at a voltage exceeding 50 V and equal or less than 400 V (peak) a.c. or d.c. under normal operating conditions, is of flammability category V-1 or better according to AS/NZS , or the printed boards are protected by an enclosure meeting the flammability category V-0 according to AS/NZS , or made of metal, having openings only for connecting wires which fill the openings completely; or - Base material of printed boards, on which the available apparatus power at a connection exceeds 15 VA operating at a voltage exceeding 400 V (peak) a.c. or d.c. under normal operating conditions, and base material of printed boards supporting spark gaps which provides protection against overvoltages, is of flammability category V-0 according to AS/NZS or the printed boards are contained in a metal enclosure, having openings only for connecting wires which fill the openings completely. Compliance shall be determined using the smallest thickness of the material. NOTE Available apparent power is the maximum apparent power which can be drawn from the supplying circuit through a resistive load whose value is chosen to maximise the apparent power for more than 2 min when the circuit supplied is disconnected Not apply for; materials have suitable flame class including fire enclosure. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 27 of 53 National Differences IEC nd ed. + A1:2009

73 IEC60950_1B - ATTACHMENT For Australia only, delete the first paragraph and Note, and replace with the following: In Australia only, compliance with shall be checked by the tests of both and For Australia only, delete the first paragraph including the Notes, and replace with the following: In Australia only, the electrical separation is subjected to 10 impulses of alternating polarity, using the impulse test generator reference 1 of Table N.1. The interval between successive impulses is 60 s and the initial voltage, Uc, is: (i) for a): 7.0 kv for hand-held telephones and for headsets and 2.5 kv for other equipment; and (ii) for b) and c): 1.5 kv. No connection to the TELECOMMUNICATION NETWORK. Ditto. NOTE 201 The 7 kv impulse simulates lightning surges on typical rural and semi-rural network lines. NOTE 202 The value of 2.5 kv for a) was chosen to ensure the adequacy of the insulation concerned and does not necessarily simulate likely overvoltages For Australia only, delete the second paragraph including the Note, and replace with the following: In Australia only, the a.c. test voltage is: (i) for a): 3 kv; and (ii) for b) and c): 1.5 kv. NOTE 201 Where there are capacitors across the insulation under test, it is recommended that d.c. test voltages are used. NOTE 202 The 3 kv and 1.5 kv values have been determined considering the low frequency induced voltages from the power supply distribution system. 7.3 Add the following before the first paragraph: Equipment providing functions that fall only within the scope of AS/NZS and that incorporate a PSTN interface, are not required to comply with this Clause where the only ports provided on the equipment, in addition to a coaxial cable connection and a PSTN interface, are audio or video ports and analogue or data ports not intended to be used for telecommunications purposes. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 28 of 53 Ditto. No connection to the CABLE DISTRIBUTION SYSTEMS. National Differences IEC nd ed. + A1:2009

74 IEC60950_1B - ATTACHMENT Annex P Add the following Normative References: Added. P AS/NZS 3191, Electric flexible cords AS/NZS 3112, Approval and test specification Plugs and socket-outlets Index 1. Insert the following between asbestos, not to be used as insulation and attitude see orientation : Inserted. AS/NZS AS/NZS AS/NZS (Table 3B) AS/NZS AS/NZS , AS/NZS , AS/NZS Insert the following between positive temperature coefficient (PTC) device and powder : Potential ignition source , , TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 29 of 53 National Differences IEC nd ed. + A1:2009

75 IEC60950_1B - ATTACHMENT Canada (CA) National standard reference.: CAN/CSA-C22.2 No SPECIAL NATIONAL CONDITIONS The following is a summary of the key national differences based on national regulatory requirements, such as the Canadian Electrical Code (CEC) Part and the Canadian Building Code, which are referenced in legislation and which form the basis for the rules and practices followed in electrical and building installations All equipment is to be designed to allow installation in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CAN/CSA C22.1, and when applicable, the National Electrical Safety Code, IEEE C2. Also, unless marked or otherwise identified, installation is allowed per the Standard for the Protection of Electronic Computer/Data-Processing Equipment, ANSI/NFPA For Pluggable Equipment Type A, the protection in the installation is assumed to be 20A For lengths exceeding 3.05 m, external interconnecting flexible cord and cable assemblies are required to be a suitable cable type (e.g., DP, CL2) specified in the CEC/NEC. For lengths 3.05 m or less, external interconnecting flexible cord and cable assemblies that are not types specified in the CEC are required to have special construction features and identification markings Equipment for use on a.c. mains supply systems with a neutral and more than one phase conductor (e.g. 120/240 V, 3-wire) require a special marking format for electrical ratings. A voltage rating that exceeds an attachment plug cap rating is only permitted if it does not exceed the extreme operating conditions in Table 2 of CAN/CSA C22.2 No. 235, and if it is part of a range that extends into the Table 2 "Normal Operating Conditions." Likewise, a voltage rating shall not be lower than the specified "Normal Operating Conditions," unless it is part of a range that extends into the "Normal Operating Conditions." No such cord or cable is provided TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 30 of 53 National Differences IEC nd ed. + A1:2009

76 IEC60950_1B - ATTACHMENT Wiring terminals intended to supply Class 2 outputs in accordance with CEC Part 1 or NEC shall be marked with the voltage rating and Class 2 or equivalent. Marking shall be located adjacent to the terminals and shall be visible during wiring. 2.5 Where a fuse is used to provide Class 2, Limited Power Source, or TNV current limiting, it shall not be operator-accessible unless it is not interchangeable Suitable NEC/CEC branch circuit protection rated at the maximum circuit rating is required for all standard supply outlets and receptacles (such as supplied in power distribution units) if the supply branch circuit protection is not suitable. Power distribution transformers distributing power at 100 volts or more, and rated 10 kva or more, require special transformer overcurrent protection. 3.2 Wiring methods (terminals, leads, etc.) used for the connection of the equipment to the mains shall be in accordance with the NEC/CEC. No such fuse used. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 31 of 53 National Differences IEC nd ed. + A1:2009

77 IEC60950_1B - ATTACHMENT Power supply cords are required to have attachment plugs rated not less than 125 percent of the rated current of the equipment Equipment connected to a centralized d.c. power system, and having one pole of the DC mains input terminal connected to the main protective earthing terminal in the equipment, is required to comply with special earthing, wiring, marking and installation instruction requirements Permanent connection of equipment to the mains supply by a power supply cord is not permitted, except for certain equipment, such as ATMs Power supply cords are required to be no longer than 4.5 m in length. Flexible power supply cords are required to be compatible with Tables 11 and 12 of the CEC and Article 400 of the NEC Permanently connected equipment is required to have a suitable wiring compartment and wire bending space. 3.3 Wiring terminals and associated spacings for field wiring connections shall comply with CSA C22.2 No Wire binding screws are not permitted to attach conductors larger than 10 AWG (5.3 mm 2 ) Terminals for permanent wiring, including protective earthing terminals, are required to be suitable for Canadian/US wire gauge sizes, rated 125 percent of the equipment rating, and be specially marked when specified (1.7.7) Motor control devices are required for cord-connected equipment with a motor if the equipment is rated more than 12 A, or if the motor has a nominal voltage rating greater than 120 V, or is rated more than 1/3 hp (locked rotor current over 43 A) Vertically-mounted disconnect switches and circuit breakers are required to have the "on" position indicated by the handle in the up position For computer room applications, equipment with battery systems capable of supplying 750 VA for five minutes are required to have a battery disconnect means that may be connected to the computer room remote power-off circuit. No motor in the equipment. No such device is used for equipment. Equipment not with battery systems. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 32 of 53 National Differences IEC nd ed. + A1:2009

78 IEC60950_1B - ATTACHMENT The maximum quantity of flammable liquid stored in equipment is required to comply with NFPA Equipment with lasers is required to meet the Canadian Radiation Emitting Devices Act, REDR C1370 and/or Code of Federal Regulations 21 CFR 1040, as applicable. 4.7 For computer room applications, automated information storage systems with combustible media greater than 0.76 m 3 (27 cu ft) are required to have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge For computer room applications, enclosures with combustible material measuring greater than 0.9 m 2 (10 sq ft) or a single dimension greater than 1.8 m (6 ft) are required to have a flame spread rating of 50 or less. For other applications, enclosures with the same dimensions require a flame spread rating of 200 or less. Annex H Equipment that produces ionizing radiation is required to comply with the Canadian Radiation Emitting Devices Act, REDR C1370 and/or Code of Federal Regulations, 21 CFR 1020, as applicable. No flammable liquids within the equipment. No laser. Such condition is not considered. Ditto. No ionizing radiation. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 33 of 53 National Differences IEC nd ed. + A1:2009

79 IEC60950_1B - ATTACHMENT OTHER DIFFERENCES The following key national differences are based on requirements other than national regulatory requirements Some components and materials associated with the risk of fire, electric shock, or personal injury are required to have component or material ratings in accordance with the applicable national (Canadian and/or U.S.) component or material standard requirements. These components include: attachment plugs, battery packs (rechargeable type, used with transportable equipment), cathode ray tubes, circuit breakers, communication circuit accessories, connectors (used for current interruption of non-lps circuits), cord sets and power supply cords, direct plug-in equipment, enclosures (outdoor), flexible cords and cables, fuses (branch circuit), fuseholders, ground-fault current interrupters, industrial control equipment, insulating tape, interconnecting cables, lampholders, limit controls, printed wiring, protectors for communications circuits, receptacles, solid state controls, supplementary protectors, switches (including interlock switches), thermal cutoffs, thermostats, (multi-layer) transformer winding wire, transient voltage surge suppressors, tubing, wire connectors, and wire and cables A circuit for connection to the DC Mains Supply is classified as either a SELV Circuit, TNV-2 Circuit or Hazardous Voltage Circuit depending on the maximum operating voltage of the supply. This maximum operating voltage shall include consideration of the battery charging float voltage associated with the intended supply system, regardless of the marked power rating of the equipment For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vpeak or 60 Vd.c., the maximum acceptable current through a 2000 ohm resistor (or greater) connected across the voltage source with other loads disconnected is 7.1 ma peak or 30 ma d.c. under normal operating conditions In the event of a single fault between TNV and SELV circuits, the limits of apply to SELV Circuits and accessible conductive parts The current rating of the circuit shall be taken as 20 A not 16 A Critical components are complied with relevant IEC standards for correct application and use. See table in test report for details. Not connected to the D.C. mains supply. No TNV circuits. No TNV circuits. P TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 34 of 53 National Differences IEC nd ed. + A1:2009

80 IEC60950_1B - ATTACHMENT Protective bonding conductors of non-standard protective bonding constructions (e.g., printed circuit traces) may be subjected to the additional limited short circuit test conditions specified Enclosures around CRTs with a face diameter of 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT Equipment with handles is required to comply with special loading tests Equipment intended to receive telecommunication ringing signals is required to comply with a special touch current measurement tests Internal (e.g., card cage) SELV circuit connectors and printed wiring board connectors that are accessible to the operator and that deliver power are to be overloaded. During abnormal operating testing, if a circuit is interrupted by the opening of a component, the test shall be repeated twice (three tests total) using new components as necessary. 6.4 Equipment intended for connection to telecommunication network outside plant cable is required to be protected against overvoltage from power line crosses in accordance with 6.4 and Annex NAC. M.2 Continuous ringing signals up to 16 ma only are permitted if the equipment is subjected to special installation and performance restrictions. Annex NAD Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements. Not appliance of CRT in the equipment. The equipment has no handles. No connection to the TELECOMMUNICATION NETWORK.. No TNV circuits. No TNV circuits. No TNV circuits. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 35 of 53 National Differences IEC nd ed. + A1:2009

81 IEC60950_1B - ATTACHMENT Germany (DE) National standard reference.: VDE : ZC A-DEVIATIONS (informative) According to GPSG, section 2, clause 4: If certain rules on the use, supplementation or maintenance of an item of technical work equipment or ready-to-use commodity must be observed in order to guarantee safety and health, instructions for use in German must be supplied when it is brought into circulation. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 36 of 53 National Differences IEC nd ed. + A1:2009

82 IEC60950_1B - ATTACHMENT Israel (IL) National standard reference.: SI Part 1 (2009) B. Add the following to the clause: Israel Standards SI 32 Part Plugs and socket-outlets for household and similar purposes: Plugs and socket-outlets for single phase up to 16 A General Requirements SI 961, all parts - Electromagnetic compatibility Israel documents Electricity Law, 1654, its regulations and revisions Kovetz Takanot 4465 dated , Consumer Protection Order (Marking of goods), 1983 TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 37 of 53 National Differences IEC nd ed. + A1:2009

83 IEC60950_1B - ATTACHMENT TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 38 of 53 National Differences IEC nd ed. + A1:2009

84 IEC60950_1B - ATTACHMENT TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 39 of 53 National Differences IEC nd ed. + A1:2009

85 IEC60950_1B - ATTACHMENT Annex P Normative Reference The annex is applicable with the following national deviations: - The following Israel Standards have been inserted in place of some of the International Standards specified in this annex of the Standard, as follows: P 6) Residual current circuit breaker (30 ma = I ); 7) Reinforced insulation; Double insulation (class II) Clause shall be added at the end of the clause, as follows: Prevention of electromagnetic interference - Prior to carrying out the tests in accordance with the clauses of the Standard, the compliance of the apparatus with the relevant requirements specified in the appropriate part of the Standard series, SI 961, shall be checked. The apparatus shall meet the requirements in the appropriate part of the Standard series SI If there are components in the apparatus for the prevention of electromagnetic interference these components shall not reduce the safety level of the apparatus as required by this Standard. Not considered. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 40 of 53 National Differences IEC nd ed. + A1:2009

86 IEC60950_1B - ATTACHMENT 3 Wiring, connections and supply The clause is applicable with the following additions: Connection to a mains supply Means of connection Connection to an a.c. mains supply After the note, the following note shall be added: Note: In Israel, the feed plus shall comply with the requirements of Israel Standard SI 32 Part Connection to a d.c. mains supply At the end of the first paragraph, the following note shall be added: Note: At the time of issue of this Standard, there is no Israel Standard for connection accessories to d.c. Note: In Israel, this clause is applicable subject to the Electricity Law, 1954, its regulations and revisions. 1.7 Marking and instructions The clause is applicable with the following additions: No direct connected to an a.c. mains supply. No direct connected to a d.c. mains supply. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 41 of 53 National Differences IEC nd ed. + A1:2009

87 IEC60950_1B - ATTACHMENT Subclause shall be added at the beginning of the clause as follows: Marking in the Hebrew language The marking in the Hebrew language shall be in accordance with the Consumer Protection Order (Marking of goods), In addition to the marking required by clause 1.7.1, the following details shall be marked in the Hebrew language. The details shall be marked on the apparatus or on its package, or on a label properly attached to the apparatus or on the package, by bonding or sewing, in a manner that the label cannot be easily removed. 1. Name of the apparatus and it commercial designation; 2. Manufacturer s name and address. If the apparatus is imported, the importer s name and address; 3. Manufacturer s registered trademark, if any; 4. Name of model and serial number, if any; 5. Country of manufacture Safety instructions and marking General The following shall be added to the clause: All the instructions and warnings related to safety shall be written in the Hebrew language. 2 Protection from hazards The clause is applicable with the following additions: Marking and instructions in English. Other languages will be provided when submitted for national approval. Ditto. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 42 of 53 National Differences IEC nd ed. + A1:2009

88 IEC60950_1B - ATTACHMENT Separation from hazardous voltages The following shall be added at the beginning of the clause: In Israel, according to the Electricity Law, 1954, and the Electricity Regulations (Earthing and means of protection against electricity of voltages up to 1,000V ) 1991, seven means of protection against electrocution are permitted, as follows: 1) TN-S Network system earthing; TN-C-S Network system earthing; 2) TT Network system earthing; 3) IT Network Insulation Terre; 4) Isolated transformer; 5) Safety extra low voltage (SELV or ELV); Note 3: The requirements of Israel Standard SI (c) may also be used to meet safety requirements for multimedia equipment. See IEC Guide 112, Guide on the safety of multimedia equipment. The list if equipment (brought in the above table) is not intended to be comprehensive and exhaustive and equipment that is not listed is not necessarily excluded from the Scope. Equipment complying with the relevant requirements in the Standard is considered suitable for use with process control equipment; automatic test equipment and similar systems requiring information processing facilities. However, this Standard does not include requirements for performance or functional characteristics of equipment. (c) In preparation TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 43 of 53 National Differences IEC nd ed. + A1:2009

89 IEC60950_1B - ATTACHMENT Additional requirements Requirements additional to those specified in this Standard may be necessary for: - Equipment intended for operation in special environments (for example, extremes of temperature; very high concentration of dust, moisture or vibration; flammable gases; and corrosive or explosive atmospheres); - Electromedical applications with physical connections to the patients; - Equipment intended to be used in vehicles, on board ships or aircraft, in tropical countries, or at altitudes greater than 2,000m. - Equipment intended for use where ingress of water may be possible. For guidance on such requirements and on relevant testing, see Annex T. The equipment is not intended to use in such conditions. Note: Attention is drawn to the fact that government authorities of some countries impose additional requirements Exclusions This Standard does not apply to the following: - Power supply systems which are not an integral part of the requirement, such as motor-generator sets, battery backup systems and transformers; - Building installation wiring; - Devices requiring no electric power. Considered. P TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 44 of 53 National Differences IEC nd ed. + A1:2009

90 IEC60950_1B - ATTACHMENT National deviations to the clauses of the International Standard 1.6 Power interface The clause is applicable with the following addition: AC Power distribution systems A note shall be added to the clause as follows: Note 1: Examples of aspects with which uninstalled components and subassemblies may not comply include the marking of the power rating and access to hazardous parts. Note 2: This Standard may be applied to the electronic parts of equipment even if that equipment does not wholly fall within its Scope, such as large-scale air conditioning systems, fire detection systems and fire extinguishing systems. Different requirements may be necessary for some applications. This Standard specifies requirements intended-to reduce risks of fire ignition, electric shock or bodily injury for the operator and layman who may come into contact with the equipment and, where specifically stated, for a service person. This Standard is intended to reduce such risks with respect to installed equipment, whether it consists of a system or interconnected units or independent units, subject to installing, operating and maintaining the equipment in the manner prescribed by the manufacturer. Examples of equipment that is in the scope of this Standard are the following: TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 45 of 53 National Differences IEC nd ed. + A1:2009

91 IEC60950_1B - ATTACHMENT Korea (KR) National standard reference.: K Plugs for the connection of the apparatus to the supply mains shall comply with the Korean requirement (KSC 8305). 8 EMC The apparatus shall comply with the relevant CISPR standards. Must be considered before marketed in Korea. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 46 of 53 National Differences IEC nd ed. + A1:2009

92 IEC60950_1B - ATTACHMENT Switzerland (CH) National standard reference.: SN EN : Ordinance on environmentally hazardous substances SR , Annex 1.7, Mercury - Annex 1.7 of SR applies for mercury. Switches containing mercury such as thermostats, relays and level controllers are not allowed Ordinance on chemical hazardous risk reduction SR , Annex 2.15 Batteries Annex 2.15 of SR applies for batteries containing cadmium and mercury. Note: Ordinance relating to environmentally hazardous substances, SR of is not longer in force and superseded by SR of (ChemRRV). 3.2 Supply cords of portable electrical appliances having a rated current not exceeding 10 A shall be provided with a plug complying with IEC (3.ed.) + am1, SEV 1011 and one of the following dimension sheets: - SEV :2009 Plug type 11, L + N, 250V 10A - SEV :2009 Plug type 12, L + N + PE, 250V 10A - SEV :2009 Plug type 15, 3L + N + PE, 250/400V 10A Supply cords of portable electrical appliances having a rated current not exceeding 16 A shall be provided with a plug complying with IEC (3.ed.) + am1, SEV 1011 and one of the following dimension sheets: - SEV :2009 Plug type 21 L + N, 250 V, 16A - SEV :2009 Plug type 23 L + N + PE, 250 V, 16A - SEV :2009 Plug type 25 3L + N + PE, 250/400V 16A NOTE 16 A plugs are not often used in Swiss domestic installation system. See TRF template regulatory requirements No switch. No batteries provided. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 47 of 53 National Differences IEC nd ed. + A1:2009

93 IEC60950_1B - ATTACHMENT USA (US) Switzerland on IECEE Website R.R. TRF templates. National standard reference.: UL , Second Edition All equipment is to be designed to allow installation in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, and when applicable, the National Electrical Safety Code, IEEE C2. Also, unless marked or otherwise identified, installation is allowed per the Standard for the Protection of Electronic Computer/Data-Processing Equipment, ANSI/NFPA For Pluggable Equipment Type A, the protection in the installation is assumed to be 20A For lengths exceeding 3.05 m, external interconnecting flexible cord and cable assemblies are required to be a suitable cable type specified in the NEC. For lengths 3.05 m or less, external interconnecting flexible cord and cable assemblies that are not types specified in the NEC are required to have special construction features and identification markings Equipment for use on a.c. mains supply systems with a neutral and more than one phase conductor (e.g. 120/240 V, 3-wire) require a special marking format for electrical ratings. 2.5 Where a fuse is used to provide Class 2, Limited Power Source, or TNV current limiting, it shall not be operator-accessible unless it is not interchangeable Suitable NEC branch circuit protection rated at the maximum circuit rating is required for all standard supply outlets and receptacles (such as supplied in power distribution units) if the supply branch circuit protection is not suitable. Power distribution transformers distributing power at 100 volts or more, and rated 10 kva or more, require special transformer overcurrent protection. 3.2 Wiring methods (terminals, leads, etc.) used for the connection of the equipment to the mains shall be in accordance with the NEC. Equipment in compliance with IEC Overall acceptance has to be evaluated during the national approval process. EUT in compliance with requirements of IEC Overall acceptance shall be evaluated during national approval. No such fuse used. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 48 of 53 National Differences IEC nd ed. + A1:2009

94 IEC60950_1B - ATTACHMENT Power supply cords are required to have attachment plugs rated not less than 125 percent of the rated current of the equipment Equipment connected to a centralized d.c. power system, and having one pole of the DC mains input terminal connected to the main protective earthing terminal in the equipment, is required to comply with special earthing, wiring, marking and installation instruction requirements Permanent connection of equipment to the mains supply by a power supply cord is not permitted, except for certain equipment, such as ATMs Power supply cords are required to be no longer than 4.5 m in length and minimum length shall be 1.5 m. Flexible power supply cords are required to be compatible with Article 400 of the NEC Permanently connected equipment must have a suitable wiring compartment and wire bending space Wire binding screws are not permitted to attach conductors larger than 10 AWG (5.3 mm 2 ) Terminals for permanent wiring, including protective earthing terminals, must be suitable for U.S wire gauge sizes, rated 125 percent of the equipment rating, and be specially marked when specified (1.7.7). The equipment is not for connected to a D.C. mains supply. The equipment is not for connected to a D.C. mains supply Motor control devices are required for cordconnected equipment with a motor if the equipment is rated more than 12 A, or if the motor has a nominal voltage rating greater than 120 V, or is rated more than 1/3 hp (locked rotor current over 43 A) Vertically-mounted disconnect switches and circuit breakers are required to have the "on" position indicated by the handle in the up position. No motor in the equipment. No such device is used for equipment For computer room applications, equipment with battery systems capable of supplying 750 VA for five minutes are required to have a battery disconnect means that may be connected to the computer room remote power-off circuit. Equipment not with battery systems The maximum quantity of flammable liquid stored in equipment is required to comply with NFPA 30. No flammable liquids within the equipment. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 49 of 53 National Differences IEC nd ed. + A1:2009

95 IEC60950_1B - ATTACHMENT Equipment with lasers is required to meet the Code of Federal Regulations 21 CFR No laser. 4.7 For computer room applications, automated information storage systems with combustible media greater than 0.76 m 3 (27 cu ft) are required to have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge. Such condition is not considered For computer room applications, enclosures with combustible material measuring greater than 0.9 m2 (10 sq ft) or a single dimension greater than 1.8 m (6 ft) are required to have a flame spread rating of 50 or less. For other applications, enclosures with the same dimensions require a flame spread rating of 200 or less. Annex H Equipment that produces ionizing radiation must comply with Federal Regulations, 21 CFR 1020 Ditto. No ionizing radiation. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 50 of 53 National Differences IEC nd ed. + A1:2009

96 IEC60950_1B - ATTACHMENT OTHER NATIONAL DIFFERENCES Some components and materials associated with the risk of fire, electric shock, or personal injury are required to have component or material ratings in accordance with the applicable national (U.S. and Canadian) component or material requirements. These components include: attachment plugs, battery packs (rechargeable type, used with transportable equipment), cathode ray tubes, circuit breakers, communication circuit accessories, connectors (used for current interruption of non-lps circuits), cord sets and power supply cords, direct plug-in equipment, enclosures (outdoor), flexible cords and cables, fuses (branch circuit), fuseholders, ground-fault current interrupters, industrial control equipment, insulating tape, interconnecting cables, lampholders, limit controls, printed wiring, protectors for communications circuits, receptacles, solid state controls, supplementary protectors, switches (including interlock switches), thermal cutoffs, thermostats, (multilayer) transformer winding wire, transient voltage surge suppressors, tubing, wire connectors, and wire and cables A circuit for connection to the DC Mains Supply is classified as either a SELV Circuit, TNV-2 Circuit or Hazardous Voltage Circuit depending on the maximum operating voltage of the supply. This maximum operating voltage it to include consideration of the battery charging float voltage associated with the intended supply system, regardless of the marked power rating of the equipment For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vpeak or 60 Vd.c., the max. acceptable current through a 2000 ohm resistor (or greater) connected across the voltage source with other loads disconnected is 7.1 ma peak or 30 ma d.c. under normal operating conditions In the event of a single fault between TNV and SELV circuits, the limits of apply to SELV Circuits and accessible conductive parts Protective bonding conductors of non-standard protective bonding constructions (e.g., printed circuit traces) may be subjected to the additional limited short circuit test conditions specified Enclosures around CRTs with a face diameter of 160 mm or more are required to reduce the risk of Critical components are complied with relevant IEC standards for correct application and use. See table in test report for details. Not connected to the D.C. mains supply. No TNV circuits. No TNV circuits. Not appliance of CRT in the equipment. P TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 51 of 53 National Differences IEC nd ed. + A1:2009

97 IEC60950_1B - ATTACHMENT injury due to the implosion of the CRT For equipment intended for mounting on racks and provided with slide/rails allowing the equipment to slide away from the rack for installation, service and maintenance, additional construction, performance and marking requirements are applicable to determine the adequacy of the slide/rails Equipment with handles is required to comply with special loading tests Equipment intended to receive telecommunication ringing signals is required to comply with a special touch current measurement tests Internal (e.g., card cage) SELV circuit connectors and printed wiring board connectors that are accessible to the operator and that deliver power are to be overloaded. During abnormal operating testing, if a circuit is interrupted by the opening of a component, the test shall be repeated twice (three tests total) using new components as necessary. 6.4 Equipment intended for connection to telecommunication network outside plant cable is required to be protected against overvoltage from power line crosses in accordance with 6.4 and Annex NAC. M.2 Continuous ringing signals up to 16 ma only are permitted if the equipment is subjected to special installation and performance restrictions. Annex NAD Annex NAF Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements. Document (paper) shredders likely to be used in a home or home office (Pluggable Equipment Type A plug configuration) are required to comply with additional requirements, including markings/instructions, protection against inadvertent reactivation of a safety interlock, disconnection from the mains supply (via provision of an isolating switch), and protection against operator access (accessibility determined via new accessibility probe & probe/wedge). No mounting on racks and provided with slide/rails. The equipment has no handles. No connection to the TELECOMMUNICATION NETWORK. No TNV circuits. No TNV circuits. No TNV circuits. Not applicable. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 52 of 53 National Differences IEC nd ed. + A1:2009

98 Note: Before placing the products in the different countries, the manufacturer must ensure that: 1. Operating Instructions, Ratings Labels and Warnings Labels written in an Accepted or Official Language of the country in question. 2. The equipment complies with the National Standards and/or Electrical Codes of the country in question. TÜV SÜD Asia Ltd. Taiwan Branch Report reference No.: F, No. 37, Sec. 2, Zhongyang S. Road, V-U0028 dev. No. 1.DOC Beitou District, Taipei City 11270, Taiwan Page 53 of 53 National Differences IEC nd ed. + A1:2009

99 Attachment No. 2 National and Group Differences for IEC st Ed. as per CB Bulletin No. 112A (2006) Countries Included: See overview on following page Attachment contains Cover page: National and Group Differences: Total: 1 page 49 pages 50 pages Explanation for Abbreviations: Possible Verdicts: P = Pass, F= Fail, = Not Applicable Remarks: Throughout this report, a point is used as the decimal separator. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 1 of 50 National Differences IEC st ed.

100 Clause Requirement - Test Result - Remark Verdict CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN :2001, Annex ZB and Annex ZC) General C: Delete all the "country" notes in the reference document according to the following list: Note Note Note Note Note Note Note Note Note 2, 7, Note 1, Note 2, Note Note Note Note 1, Note Note 1, Note Note Note Note Note Note Note 7 Note Note G2.1 Note 1, 2 Annex H Note S (DK): Certain types of Class I appliances (see ) may be provided with a plug not establishing earthing conditions when inserted into Danish socket-outlets A (SE, Ordinance 1990:944 and CH, Ordinance on environmentally hazardous substances SR , Annex 3.2, Mercury): Add NOTE Switches containing mercury such as thermostats, relays and level controllers are not allowed S (NO): Due to the IT power system used (see annex V, Fig. V.7), capacitors are required to be rated for the applicable line-to-line voltage (230 V) S (FI, NO, SE): Class I pluggable equipment type A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text in the applicable countries shall be as follows: FI: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun pistorasiaan" NO: "Apparatet må tilkoples jordet stikkontakt" SE: "Apparaten skall anslutas till jordat uttag" There are no components containing mercury in the equipment. P P P 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 2 of 50 National Differences IEC st ed.

101 Clause Requirement - Test Result - Remark Verdict A (DK, Heavy Current Regulations): Supply cords of class I equipment, which is delivered without a plug, must be provided with a visible tag with the following text: Vigtigt! Lederen med grøn/gul isolation må kun tilsluttes en klemme mærket eller If essential for the safety of the equipment, the tag must in addition be provided with a diagram which shows the connection of the other conductors, or be provided with the following text: "For tilslutning af de øvrige ledere, se medfølgende instalationsvejledning." S (DK): Socket-outlets for providing power to other equipment shall be in accordance with the Heavy Current Regulations, Section D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For stationary equipment the socket-outlet shall be in accordance with Standard Sheet DK 1-1b or DK 1-5a A (DK, Heavy Current Regulations): class II equipment shall not be fitted with socketoutlets for providing power to other equipment A (DE, Gesetz über techische Arbeitsmittel (Gerätesicherheitsgesetz) [Law on technical labour equipment {Equipment safety law}], of 23rd October 1992, Article 3, 3rd paragraph, 2nd sentence, together with the "Allgemeine Verwaltungsvorschrift zur Durchführung des Zweiten Abschnitts des Gerätesicherheitsgesetzes" [General administrative regulation on the execution of the Second Section of the Equipment safety law], of 10th January 1996, article 2, 4th paragraph item 2): Directions for use with rules to prevent certain hazards for (among others) maintenance of the technical labour equipment, also for imported technical labour equipment shall be written in the German language. NOTE: Of this requirement, rules for use even only by service personnel are not exempted A (CH, Ordinance on environmentally hazardous substances SR ): Annex 4.10 of SR applies for batteries. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 3 of 50 National Differences IEC st ed.

102 Clause Requirement - Test Result - Remark Verdict A (DE, Regulation on protection against hazards by X-ray, of 8th January 1987, Article 5 [Operation of X-ray emission source], clauses 1 to 4): a) A licence is required by those who operate an X-ray emission source. b) A licence in accordance with Cl. 1 is not required by those who operate an X-ray emission source on which the electron acceleration voltage does not exceed 20 kv if 1) the local dose rate at a distance of 0,1 m from the surface does not exceed 1 μsv/h and 2) it is adequately indicated on the X-ray emission source that i) X-rays are generated and ii) the electron acceleration voltage must not exceed the maximum value stipulated by the manufacturer or importer. c) A licence in accordance with Cl. 1 is also not required by persons who operate an X-ray emission source on which the electron acceleration voltage exceeds 20 kv if 1) the X-ray emission source has been granted a type approval and 2) it is adequately indicated on the X-ray emission source that i) X-rays are generated ii) the device stipulated by the manufacturer or importer guarantees that the maximum permissible local dose rate in accordance with the type approval is not exceeded and iii) the electron acceleration voltage must not exceed the maximum value stipulated by th manufacturer or importer. d) Furthermore, a licence in accordance with Cl. 1 is also not required by persons who operate X-ray emission sources on which the electron acceleration voltage does not exceed 30 kv if 1) the X-rays are generated only by intrinsically safe CRTs complying with Enclosure III, No. 6, 2) the values stipulated in accordance with Enclosure III, No. 6.2 are limited by technical measures and specified in the device and 3) it is adequately indicated on the X-ray emission source that the X-rays generated are adequately screened by the intrinsically safe CRT. No X-ray. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 4 of 50 National Differences IEC st ed.

103 Clause Requirement - Test Result - Remark Verdict S (NO): Requirements according to this annex, and apply S (NO): Requirements according to this annex, apply and S (NO): Requirements according to this annex, and apply S (GB): The current rating of the circuit shall be taken as 13 A, not 16 A C: Replace the subclause as follows: Basic requirements To protect against excessive current, shortcircuits and earth faults in primary circuits, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, shortcircuit and earth fault protection may be provided by protective devices in the building installation; c) it is permitted for pluggable equipment type B or permanently connected equipment, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for pluggable equipment type A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet. S (GB): To protect against excessive currents and short-circuits in the primary circuit of direct plug-in equipment, protective device shall be included as integral parts of the direct plug-in equipment. No TNV circuits. No TNV circuits C: Void C: Replace in the first line "(see also 1.4.7)" by "(see also 1.4.8)". 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 5 of 50 National Differences IEC st ed.

104 Clause Requirement - Test Result - Remark Verdict S (NO): Due to the IT power distribution system used (see annex V, Fig. V.7), the a.c. mains supply voltage is considered to be equal to the line-to-line voltage and will remain at 230 V in case of a single earth fault S (CH): Supply cords of equipment having a rated current not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC and one of the following dimension sheets: SEV , Plug type 15, 3P+N+PE 250/400 V, 10 A SEV , Plug type 11, L+N 250 V, 10 A SEV , Plug type 12, L+N+PE 250 V, 10 A In general, EN applies for plugs for currents exceeding 10A. However, a 16 A plug and socket-outlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998: SEV , Plug type 25, 3L+N+PE 230/400 V, 16 A SEV , Plug type 21, L+N 250 V, 16 A SEV , Plug type 23, L+N+PE 250 V, 16 A S (DK): Supply cords of single-phase equipment having a rated current not exceeding 13 A shall be provided with a plug according to the Heavy Current Regulations, Section D1. Class I equipment provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If ply-phase equipment and single-phase equipment having a rated current exceeding 13 A is provided with a supply cord with a plug, this plug shall be in accordance with the Heavy Current Regulations, Section D1 or EN F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 6 of 50 National Differences IEC st ed.

105 Clause Requirement - Test Result - Remark Verdict S (ES): Supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315:1994. Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UNE-EN 50075:1993. Class I equipment provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UNE 20315:1994. If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UNE-EN S (GB): Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a 'standard plug' in accordance with Statutory Instrument 1768:1994 The Plugs and Socket etc. (Safety) Regulations 1994, unless exempted by those regulations. NOTE 'Standard plug' is defined in SI 1768:1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug. S (IE): Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525:1997 National Standards Authority of Ireland (section 28) (13 A Plugs and Conversion Adaptors for Domestic Use) Regulations C: Delete Note 1 and in Table 3A, delete the conduit sizes in parentheses. Deleted. (Not permanently connected equipment). 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 7 of 50 National Differences IEC st ed.

106 Clause Requirement - Test Result - Remark Verdict C: Replace "60245 IEC 53" by "H05 RR-F"; "60227 IEC 52" by "H03 VV-F or H03 VVH2-F"; "60227 IEC 53" by "H05 VV-F or H05 VVH2-F2". In Table 3B, replace the first four lines by the following: Up to and including 6 0,75 1) Over 6 up to and including 10 (0,75) 2) 1,0 Over 10 up to and including 16 (1,0) 3) 1,5 In the Conditions applicable to Table 3B delete the words "in some countries" in condition 1). In Note 1, applicable to Table 3B, delete the second sentence S (GB): A power supply cord with conductor of 1,25 mm 2 is allowed for equipment with a rated current over 10 A and up to and including 13 A C: In table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following: "Over 10 up to and including 16 1,5 to 2,5 1,5 to 4" Delete the fifth line: conductor sizes for 13 to 16 A S (GB): The range of conductor sizes of flexible cords to be accepted by terminals for equipment with A RATED CURRENT of over 10 A up to and including 13 A is: - 1,25 mm 2 to 1,5 mm 2 nominal cross-sectional area S (GB): The torque test is performed using a socket outlet complying with BS 1363 and the plug part OF DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, and 12.17, except that the test of is performed at not less than 125 C. S (IE): DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such devices shall comply with Statutory Instrument 526:1997 National Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, C: Add the following note: NOTE Attention is drawn to 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards taking into account this recommendation are currently under development S (FI, NO, SE): Add the following text between the first and second paragraph: Replaced. Deleted. Not direct plug-in equipment. Not direct plug-in equipment. Added. No TNV circuits. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 8 of 50 National Differences IEC st ed.

107 Clause Requirement - Test Result - Remark Verdict If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES AND CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINGE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with EN :1994, subclass Y2. A capacitor classified Y3 according to EN :1994, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN 60950:2000, ; - the additional testing shall be performed on all the test specimens as described in EN ; - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN S (FI, NO, SE): The exclusions are applicable for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE EQUIPMENT TYPE B and equipment intended to be used in a RESTRICTED ACCESS LOCATION where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected PROTECTIVE EARTHING CONDUCTOR and is provided with instructions for the installation of that conductor by a service person. No TNV circuits. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 9 of 50 National Differences IEC st ed.

108 Clause Requirement - Test Result - Remark Verdict 7.1 S (FI, NO, SE): Requirements according to this annex, and apply with the term TELECOMMUNICATION NETWORK in being replaced by the term CABLE DISTRIBUTION SYSTEM. G.2.1 Annex H Annex P Annex Q S (NO): Due to the IT power distribution system used (see annex V, Fig. V.7), the A.C. MAINS SUPPLY voltage is considered to be equal to the line-to-line voltage, and will remain at 230 V in case of a single earth fault. NOTE These values appear in Directive 96/29/Euratom. Delete Note 2. Not intended to be connected to cable distribution system. C: Replace the last paragraph of this annex by: Replaced. At any point 10 cm from the surface of the operator access area, the dose rate shall not exceed 1 Sv/h (0,1 mr/h) (see note). Account is taken of the background level. Replace the notes as follows: C: Replace the text of this annex by: See annex ZA. Replaced. C: Replace the title of IEC by "Protection of persons and equipment by enclosures Probes for verification". Add the following notes for the standards indicated: IEC NOTE Harmonized as EN (Series) (not modified) IEC NOTE Harmonized as HD S4:2000 (modified) IEC NOTE Harmonized as EN 60529:1991 (not modified) IEC NOTE Harmonized as EN 61032:1998 (not modified) IEC NOTE Harmonized as EN 61140:2001 (not modified) ITU-T Recommendation K.31 NOTE in Europe, the suggested document is EN P P 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 10 of 50 National Differences IEC st ed.

109 Clause Requirement - Test Result - Remark Verdict Annex ZA C: NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR RELEVANT EUROPEAN PUBLICATIONS This European Standard incorporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication referrd to applies (including amendments). NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. IEC IEC EN 60065: corr. June 1999 IEC (mod):1998 EN 60073:1996 IEC 60073:1996 HD 566 S1:1990 IEC 60085:1984 HD 214 S2:1980 IEC 60112:1979 HD S1:1992 IEC :1990 HD 21 1) Series IEC (mod) Series HD 22 2) Series IEC (mod) Series EN Series IEC Series EN :1997 IEC :1997 EN Series IEC (mod) Series HD S2:1995 IEC (mod):1993 HD S2:1996 IEC (mod):1992 3) EN :1994 4) IEC : A2: A3: A4:2001 EN IEC HD S1: corr. Nov IEC (mod):1992 EN :1994 IEC :1991 EN :2001 IEC :2000 IEC :1995 IEC :1995 IEC :2000 IEC :2000 EN :1999 IEC :1999 EN :1999 IEC :1999 EN :2000 IEC :1999 (mod) EN : corr. Febr IEC :1993 A11: corr. July 1997 EN :2000 IEC :2000 IEC :1999 EN :1996 IEC :1996 EN :1996 IEC :1996 EN :1996 IEC :1996 IEC :1987 EN 60990:1999 IEC 60990:1999 IEC :2000 EN 61965:2001 IEC 61965:2000 EN ISO 178:1996 ISO 178:1993 EN ISO 179 Series ISO 179 Series EN ISO 180:2000 ISO 180:1993 ISO 261:1998 ISO 262:1998 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 11 of 50 National Differences IEC st ed. P

110 Clause Requirement - Test Result - Remark Verdict EN ISO 527 Series ISO 527 Series ISO 386:1984 EN ISO 4892 Series ISO 4892 Series ISO 7000:1989 EN ISO 8256:1996 ISO 8256:1990 ISO 9772:1994 EN ISO 9773:1998 ISO 9773:1998 ITU-T:1988 Recommendation K.17 ITU-T:2000 Recommendation K.21 1) The HD 21 series is related to, but not directly equivalent with the IEC series 2) The HD 22 series is related to, but not directly equivalent with the IEC series 3) IEC :1992 is superseded by IEC :2001 4) EN , Sectional Specification: Fixed capacitors for electromagnetic interference suppression and connection to the supply mains (Assessment level D), and its amendments are related to, but not directly equivalent to IEC P 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 12 of 50 National Differences IEC st ed.

111 Clause Requirement - Test Result - Remark Verdict ATTACHMENT TO TEST REPORT IEC NATIONAL DIFFERENCES Information technology equipment Safety Part 1: General requirements Australia (AU) National standard reference.: AS/NZS :2003 ZZ1 ZZ2 INTRODUCTION This Annex sets out variations between this Standard and IEC :2001. These variations indicate national variations for purposes of the IECEE CB Scheme and will be published in the IECEE CB Bulletin. These variations are indicated within the body of the Standard. VARIATIONS The variations are as follows: 1.2 Between the definitions for Person, service and Range, rated frequency insert the following: l ignition source After the definition of , add the following: potential ignition source: Possible fault which can start a fire if the opencircuit voltage measured across an interruption or faulty contact exceeds a value of 50 V (peak) a.c. or d.c. and the product of the peak value of this voltage and the measured r.m.s current under normal operating conditions exceeds 15 VA. Such a faulty contact or interruption in an electrical connection includes those which may occur in conductive patterns on printed boards. NOTE 201 An electronic protection circuit may be used to prevent such a fault from becoming a POTENTIAL IGNITION SOURCE. NOTE 202 This definition is from AS/NZS 60065: Add the following to the end of first paragraph: or the relevant Australian/New Zealand Standard Add the following to the end of first and third dash items: or the relevant Australian/New Zealand Standard. Not considered. Ditto. Added. Added. 2.1 Delete the Note. Delete. P Delete Note 2. Not permanently connected equipment Modify Table 3B as follows: Delete the first four rows and replace with 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 13 of 50 National Differences IEC st ed.

112 Clause Requirement - Test Result - Remark Verdict RATED CURRENT of equipment A Over 0.2 up to and including 3 Over 3 up to and including 7.5 Over 7.5 up to and including 10 Over 10 up to and including 16 Minimum conductor sizes Nominal cross-sectional area mm 2 AWG or kcmil [cross-sectional area in mm 2 ] See note 2 0,5 1) 18 [0,8] 0,75 16 [1,3] (0,75) 2) 1,00 16 [1,3] (1,0) 3) 1,5 14 [2] Replace footnote 1) with the following: 1) This nominal cross-sectional area is only allowed for Class II appliances if the length of the power supply cord, measured between the point where the cord, or cord guard, enters the appliance, and the entry to the plug does not exceed 2 m (0.5 mm2 three-core supply flexible cords are not permitted; see AS/NZS 3191). Delete Note Add the following after the last Paragraph of Clause 4.1: Display devices used for television purposes Display devices which may be used for television purposes, with a mass of 7 kg or more, shall comply with the requirements for stability and mechanical hazards, including the additional stability requirements for television receivers, specified in AS/NZS Replace paragraph three with: Equipment with a plug portion, suitable for insertion into a 10 A 3-pin flat-pin socket-outlet complying with AS/NZS 3112, shall comply with the requirements in AS/NZS 3112 for equipment with integral pins for insertion into socket-outlets Add the following to the end of the first paragraph:, or AS/NZS Add the following paragraph: For alternative tests refer to Clause No display devices. Unit is not DIRECT PLUG-IN EQUIPMENT. Added the paragraph. Refer to below. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 14 of 50 National Differences IEC st ed.

113 Clause Requirement - Test Result - Remark Verdict Add the following after Clause Resistance to fire Alternative tests General Parts of non-metallic material shall be resistant to ignition and spread of fire. This requirement does not apply to decorative trims, knobs and other parts unlikely to be ignited or to propagate flames originating from inside the apparatus, or the following: (a) Components that are contained in an enclosure having a flammability category of FV-0 according to AS/NZS and having openings only for the connecting wires filling the openings completely, and for ventilation not exceeding 1 mm in width regardless of length. Not apply for; materials have suitable flame class including fire enclosure. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 15 of 50 National Differences IEC st ed.

114 Clause Requirement - Test Result - Remark Verdict (b) The following parts which would contribute negligible fuel to a fire: - small mechanical parts, the mass of which does not exceed 4 g, such as mounting parts, gears, cams, belts and bearings; - small electrical components, such as capacitors with a volume not exceeding mm3, integrated circuits, transistors and optocoupler packages, if these components are mounted on material of flammability category FV-1, or better, according to AS/NZS NOTE In considering how to minimize propagation of fire and what small parts are, account should be taken of the cumulative effect of small parts adjacent to each other for the possible effect of propagating fire from one part to another. Compliance shall be checked by the tests of , , and For the base material of printed boards, compliance shall be checked by the test of The tests shall be carried out on parts of nonmetallic material which have been removed from the apparatus. When the glow-wire test is carried out, the parts shall be placed in the same orientation as they would be in normal use. These tests are not carried out on internal wiring Testing of non-metallic materials Parts of non-metallic material shall be subject to the glow-wire test of AS/NZS which shall be carried out at 550 C. Parts for which the glow-wire test cannot be carried out, such as those made of soft or foamy material, shall meet the requirements specified in ISO 9772 for category FH-3 material. The glow-wire test shall be not carried out on parts of material classified at least FH-3 according to ISO 9772 provided that the sample tested was not thicker than the relevant part Testing of insulating materials Parts of insulating material supporting POTENTIAL IGNITION SOURCES shall be subject to the glow-wire test of AS/NZS which shall be carried out at 750 C. Ditto. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 16 of 50 National Differences IEC st ed.

115 Clause Requirement - Test Result - Remark Verdict The test shall be also carried out on other parts of insulating material which are within a distance of 3mm of the connection. NOTE Contacts in components such as switch contacts are considered to be connections. For parts which withstand the glow-wire test but produce a flame, other parts above the connection within the envelope of a vertical cylinder having a diameter of 20 mm and a height of 50 mm shall be subjected to the needle-flame test. However, parts shielded by a barrier which meets the needle-flame test shall not be tested. The needle-flame test shall be made in accordance with AS/NZS with the following modifications: Clause of Change AS/NZS Severities Replace with: The duration of application of the test flame shall be 30 s ±1 s. 8 Test procedure 8.2 Replace the first sentence with: The specimen shall be arranged so that the flame can be applied to a vertical or horizontal edge as shown in the examples of figure The first paragraph does not apply. Addition: If possible, the flame shall be applied at least 10 mm from a corner. 8.5 Replace with: The test shall be made on one specimen. If the specimen does not withstand the test, the test may be repeated on two further specimens, both of which shall then withstand the test. 10 Evaluation of test results Replace with: The duration of burning (tb) shall not exceed 30 s. However, for printed circuit boards, it shall not exceed 15 s. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 17 of 50 National Differences IEC st ed. Ditto.

116 Clause Requirement - Test Result - Remark Verdict The needle-flame test shall not be carried out on parts of material classified as V- 0 or V-1 according to IEC , provided that the sample tested was not thicker than the relevant part Testing in the event of non-extinguishing material If parts, other than enclosures, do not withstand the glow wire tests of , by failure to extinguish within 30 s after the removal of the glow-wire tip, the needle-flame test detailed in shall be made on all parts of non-metallic material which are within a distance of 50 mm or which are likely to be impinged upon by flame during the tests of Parts shielded by a separate barrier which meets the needle-flame test need not be tested. NOTE 1 - If the enclosure does not withstand the glow-wire test the equipment is considered to have failed to meet the requirements of Clause without the need for consequential testing. NOTE 2 - If other parts do not withstand the glow-wire test due to ignition of the tissue paper and if this indicates that burning or glowing particles can fall onto an external surface underneath the equipment, the equipment is considered to have failed to meet the requirements of Clause without the need for consequential testing. NOTE 3 - Parts likely to be impinged upon by the flame are considered to be those within the envelope of a vertical cylinder having a radius of 10 mm and a height equal to the height of the flame, positioned above the point of the material supporting, in contact with, or in close proximity to, connections Testing of printed boards The base material of printed boards shall be subjected to the needle-flame test of Clause The flame shall be applied to the edge of the board where the heat sink effect is lowest when the board is positioned as in normal use. The flame shall not be applied to an edge, consisting of broken perforations, unless the edge is less than 3 mm from a POTENTIAL IGNITION SOURCE. The test is not carried out if the - Printed board does not carry any POTENTIAL IGNITION SOURCE; - Base material of printed boards, on which the available apparent power at a connection exceeds 15 VA operating at a voltage exceeding 50 V and equal or less than 400 V (peak) a.c. or d.c. under normal operating conditions, is of flammability category FV-1 or better according to AS/NZS , or the printed boards are protected by an enclosure meeting the flammability category FV-0 according to AS/NZS , or made of metal, having openings only for connecting wires which fill the openings completely; - or Base material of printed boards, on which the available apparatus power at a connection exceeds 15 VA operating at a voltage exceeding 400 V (peak) a.c. or d.c. under normal operating conditions, and base material of printed boards supporting spark gaps which provides protection against overvoltages, is of flammability category FV-0 according to AS/NZS or the printed boards are contained in a metal enclosure, having openings only for connecting wires which fill the openings completely. Compliance shall be determined using the smallest thickness of the material. NOTE Available apparent power is the maximum apparent power which can be drawn from the supplying circuit through a resistive load whose value is chosen to maximise the apparent power for more than 2 min when the circuit supplied is disconnected. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 18 of 50 National Differences IEC st ed.

117 Clause Requirement - Test Result - Remark Verdict Add the symbol NZ in the right hand margin beside the first paragraph. Add the following after the first paragraph: In Australia (this variation does not apply in New Zealand), compliance with shall be checked by the tests of both and Delete the note Add the symbol NZ in the right hand margin beside the first paragraph including Note 1. Delete Note 2 Add the following after the first paragraph: In Australia (this variation does not apply in New Zealand), the electrical separation is subjected to 10 impulses of alternating polarity, using the impulse test generator of annex N for 10/700µs impulses. The interval between successive impulses is 60 s and the initial voltage, Uc, is: - for a): 7.0 kv for hand-held telephones and for headsets and 2.5 kv for other equipment; and - for b) and c): 1.5 kv. NOTE 201 The 7 kv impulse simulates lightning surges on typical rural and semi-rural network lines. NOTE 202 The value of 2.5 kv for a) was chosen to ensure the adequacy of the insulation concerned and does not necessarily simulate likely overvoltages Add the symbol NZ in the right hand margin beside the second paragraph. Delete the Note. Add the following after the second paragraph: In Australia (this variation does not apply in New Zealand), the a.c. test voltage is: - for a): 3 kv; and - for b) and c): 1.5 kv. NOTE 201 Where there are capacitors across the insulation under test, it is recommended that d.c. test voltages are used. NOTE 202 The 3 kv and 1.5 kv values have been determined considering the low frequency induced voltages from the power supply distribution system. No connection to the TELECOMMUNICATION NETWORK. Ditto. Ditto. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 19 of 50 National Differences IEC st ed.

118 Clause Requirement - Test Result - Remark Verdict 7.2 Add the following before the first paragraph: Equipment providing functions that fall only within the scope of AS/NZS and that incorporate a PSTN interface, are not required to comply with this Clause where the only ports provided on the equipment, in addition to a coaxial cable connection and a PSTN interface, are audio or video ports and analogue or data ports not intended to be used for telecommunications purposes. Annex P Index Add the following Normative References to Annex P: IEC 60065, Audio, Video and similar electronic apparatus Safety requirements AS/NZS 3191, Approval and test specification Electric flexible cords AS/NZS 3112, Approval and test specification Plugs and socket-outlets AS/NZS , Fire hazard testing of electrotechnical products Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source Between the entries for polyimide insulating material and powder insert the following: potential ignition source , , No connection to the CABLE DISTRIBUTION SYSTEMS. Added. Inserted. P 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 20 of 50 National Differences IEC st ed.

119 Clause Requirement - Test Result - Remark Verdict Canada (CA) National standard reference.: CAN/CSA C22.2 No /UL Canada and the United States of America have adopted a single, bi-national standard, CAN/CSA C22.2 No /UL , First Edition, which is based on IEC , First Edition. Effective April 1, 2003, this standard may be used for product certification immediately, however, the previous version of the standard may also be used until April 1, Note: The previous version is CAN/CSA C22.2 No /UL Third Edition, based on IEC 60950, 3 rd Edition. Refer to the IEC 60950, 3rd Edition, CA section of this CB bulletin for the national differences in this version of the standard. This bi-national standard should be consulted for further details on the Special National Conditions and Other Differences summarized below. SPECIAL NATIONAL CONDITIONS Those requirements are identified as Special National Conditions since they are directly related to the Canadian Electrical code (CEC), Part 1 and the Canadian Building Code, which are referenced in legislation and which form the basis for the rules and practices followed in electrical and other building installations in Canada. Notes: CEC denotes Canadian Electrical Code. NEC denotes US National Electrical Code. Due to common Canadian and US national differences, products that are in compliance with the Canadian national differences are also considered in compliance with the US national differences All equipment is to be designed to allow installation in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, the Canadian Electrical Code (CEC), Part I, CAN/CSA C22.1, and when applicable, the National Electrical Safety Code, IEEE C2. Also, unless marked or otherwise identified, installation is allowed per the Standard for the Protection of Electronic Computer/Data-Processing Equipment, ANSI/NFPA For Pluggable Equipment Type A, the protection in the installation is assumed to be 20A For lengths exceeding 3.05 m, external interconnecting flexible cord and cable assemblies are required to be a suitable cable type (e.g. DP, CL2) specified in the NEC. For lengths 3.05 m or less, external interconnecting flexible cord and cable assemblies that are not types specified in the NEC are required to have special construction features and identification markings. No such cord or cable is provided 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 21 of 50 National Differences IEC st ed.

120 Clause Requirement - Test Result - Remark Verdict Equipment for use on a.c. mains supply systems with a neutral and more than one phase conductor (e.g. 120/240 V, 3-wire) require a special marking format for electrical ratings. A voltage rating that exceeds an attachment plug cap rating is only permitted if it does not exceed the extreme operating conditions in Table 2 of CAN/CSA C22.2 No. 235, and if it is part of a range that extends into the Table 2 "Normal Operating Conditions." Likewise, a voltage rating shall not be lower than the specified "Normal Operating Conditions," unless it is part of a range that extends into the "Normal Operating Conditions." 2.5 Where a fuse is used to provide Class 2, Limited Power Source, or TNV current limiting, it shall not be operator-accessible unless it is not interchangeable Suitable NEC/CEC branch circuit protection rated at the maximum circuit rating is required for all standard supply outlets, receptacles and medium-base or smaller lampholders if the supply branch circuit protection is not suitable. Power distribution transformers distributing power at 100 volts or more, and rated 10 kva or more, require transformer overcurrent protection. 3.2 Wiring methods (terminals, leads, etc.) used for the connection of the equipment to the mains shall be in accordance with the NEC/CEC Power supply cords are required to have attachment plugs rated not less than 125 percent of the rated current of the equipment Permanent connection of equipment to the mains supply by a power supply cord is not permitted, except for certain equipment, such as ATMs Power supply cords are required to be no longer than 4.5 m in length. Flexible power supply cords are required to be compatible with Article 400 of the NEC, and Tables 11 and 12 of the CEC Permanently connected equipment is required to have a suitable wiring compartment and wire bending space. 3.3 Wiring terminals and associated spacings for field wiring connections shall comply with CSA C22.2 No. 0. No such fuse used. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 22 of 50 National Differences IEC st ed.

121 Clause Requirement - Test Result - Remark Verdict Wire binding screws are not permitted to attach conductors larger than 10 AWG (5.3 mm 2 ) Terminals for permanent wiring, including protective earthing terminals, are required to be suitable for U.S./Canadian wire gauge sizes, rated 125 percent of the equipment rating, and be specially marked when specified (1.7.7) Motor control devices are required for cordconnected equipment with a motor if the equipment is rated more than 12 A, or if the motor has a nominal voltage rating greater than 120 V, or is rated more than 1/3 hp (locked rotor current over 43 A) Vertically-mounted disconnect switches and circuit breakers are required to have the "on" position indicated by the handle in the up position For computer room applications, equipment with battery systems capable of supplying 750 VA for five minutes are required to have a battery disconnect means that may be connected to the computer room remote power-off circuit The maximum quantity of flammable liquid stored in equipment is required to comply with NFPA Equipment with lasers is required to meet the Code of Federal Regulations 21 CFR 1040 (and the Canadian Radiation Emitting Devices Act, REDR C1370). 4.7 For computer room applications, automated information storage systems with combustible media greater than 27 cubic feet are required to have a provision for connection of either automatic sprinklers or a gaseous agent extinguishing system with an extended discharge For computer room applications, enclosures with combustible material measuring greater than 0.9 m2 or a single dimension greater than 1.8 m are required to have a flame spread rating of 50 or less. For other applications, enclosures with the same dimensions require a flame spread rating of 200 or less. Annex H Equipment that produces ionizing radiation is required to comply with the Code of Federal Regulations, 21 CFR 1020 (and the Canadian Radiation Emitting Devices Act, REDR C1370). No motor in the equipment. No such device is used for equipment. Equipment not with battery systems. No flammable liquids within the equipment. No laser. Such condition is not considered. Ditto. No ionizing radiation. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 23 of 50 National Differences IEC st ed.

122 Clause Requirement - Test Result - Remark Verdict OTHER DIFFERENCES The following key national differences are based on requirements other than national regulatory requirements. The bi-national standard (CAN/CSA C22.2 No /UL , First Edition) referenced above should be consulted for further details on the national differences summarized below Components of equipment must be suitable for the application, and must comply with the requirements of the equipment standard and the applicable national (Canadian and/or U.S.) component or material standards, as far as they may apply. The acceptance will be based on the following: A) A component Certified by a Canadian or U.S. National Certification Body (NCB) to a Canadian or U.S. component standard will be checked for correct application and use in accordance with its specified rating. Where necessary, it will also be subject to the applicable tests of the equipment standard. B) A component, which has a CB Test Certificate for compliance with a relevant IEC component standard, will be checked for correct application and use in accordance with its specified ratings. Where necessary, it will also be subject to the applicable tests of the equipment standard, and to the applicable tests of the Canadian and/or U.S. component or material standard, under the conditions occurring in the equipment. C) A component, which has no approval as in A) or B) above or which is used not in accordance with its specified ratings, will be subject to the applicable tests of the equipment standard, and to the applicable tests of the Canadian and/or U.S. component or material standard, under the conditions occurring in the equipment. D) Some components may require annual re-testing, which may be carried out by the manufacturer, CSA International or another laboratory Critical components are complied with relevant IEC standards for correct application and use. See table in test report for details. P 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 24 of 50 National Differences IEC st ed.

123 Clause Requirement - Test Result - Remark Verdict For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vpeak or 60 Vd.c., the maximum acceptable current through a 2000 ohm resistor (or greater) connected across the voltage source with other loads disconnected is 7.1 ma peak or 30 ma d.c. under normal operating conditions In the event of a single fault, the limits of apply to SELV Circuits and accessible conductive parts When subject to impedance testing, protective earthing and bonding are required to be subjected to the additional test conditions specified Equipment connected to a centralized d.c. power system, and having one pole of the DC mains input terminal connected to the main protective earthing terminal in the equipment, is required to comply with special earthing, wiring, marking and installation instructions requirements Enclosures around CRTs with a face diameter of 160 mm or more are required to reduce the risk of injury due to the implosion of the CRT Equipment with handles is required to comply with special loading tests Equipment intended to receive telecommunication ringing signals is required to comply with a special touch current measurement tests Enamel coating on winding wire not considered electrical separation unless subjected to special investigation. 6.4 Equipment intended for connection to telecommunication network outside plant cable is required to be protected against overvoltage from power line crosses in accordance with 6.4 and Annex NAC. 6.5 Equipment connected to a telecommunications network and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure tests. M.2 Continuous ringing signals up to 16 ma only are permitted if the equipment is subjected to special installation and performance restrictions. No TNV circuits. No TNV circuits. Equipment not supplied from such power system. Not appliance of CRT in the equipment. The equipment has no handles. No connection to the TELECOMMUNICATION NETWORK. Such coating is not regarded as electrical separation. No TNV circuits. Ditto. Not apply for. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 25 of 50 National Differences IEC st ed.

124 Clause Requirement - Test Result - Remark Verdict Japan (JP) National standard reference.: J (H22) Add the following new NOTE A NOTE Even if the equipment is designed as Class I, the equipment is regarded as Class 0I equipment when a 2-pin adaptor with an earthing lead wire or a cord set having a 2-pin plug with an earthing lead wire is provided or recommended. Add the following new clause A CLASS 0I EQUIPMENT Equipment having attachment plug without earthing blade, where protection against electric shock is achieved by: - using BASIC INSULATION, and - providing externally an earth terminal or a lead wire for earthing in order to connect those conductive parts that might assume a HAZARDOUS VOLTAGES in the event of BASIC INSULATION fault to the PROTECTIVE EARTHING CONDUCTOR in the building wiring. NOTE Class 0I equipment may have a part constructed with Double Insulation or Reinforced Insulation. circuit Add the following notes after the first paragraph: NOTE 1 Transportable or similar equipment that is relocated frequently for intended usage should not be designed as Class I or Class 0I equipment unless it is intended to be installed by service personnel. NOTE 2 Considering wiring circumstance in Japan, equipment intended to be installed where the provision for earthling connection is unlikely should not be designed as Class I or Class 0I equipment unless it is intended to be installed by service personnel. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 26 of 50 National Differences IEC st ed.

125 Clause Requirement - Test Result - Remark Verdict Replace the first paragraph with the following: Where safety is involved, components shall comply either with the requirements of this standard or with the safety aspects of the relevant JIS component standard or IEC component standards in case there is no applicable JIS component standard is available. However, in case a component that falls within the scope of the METI Ministerial ordinance (No. 85:1962) is properly used in accordance with its marked ratings, the requirements of 1.5.4, and apply, and in addition, a cord connector of power supply cord set matching with an appliance inlet specified in the standard sheets of IEC , shall comply with relevant standard sheet of IEC Replace NOTE 1 with the following: NOTE 1 A JIS or an IEC component standard is considered relevant only if the component in question clearly falls within its scope. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 27 of 50 National Differences IEC st ed.

126 Clause Requirement - Test Result - Remark Verdict Replace the first sentence in the first dashed paragraph with the following: - a component that has been demonstrated to comply with a JIS component standard harmonized with the relevant IEC component standard, or where such JIS component standard is not available, a component that has been demonstrated to comply with the relevant IEC component standard shall be checked for correct application and use in accordance with its rating. Add a NOTE after the first dashed paragraph as follows: NOTE 1 See 1.7.5A when Type C.14 appliance coupler rated 10 A per IEC is used with an equipment rated not more than 125 V and rated more than 10 A. Replace the first sentence in the third dashed paragraph as follows: - where no relevant IEC component standard or JIS component standard harmonized with the relevant IEC component standard exists, or where components are used in circuits not in accordance with their specified rating, the components shall be tested under the conditions occurring in the equipment In this sub-clause, add JIS C :1998 or before the reference number, IEC : In this sub-clause, add JIS C :1998 or before the reference number, IEC : In the first paragraph, add JIS C :1998 or before the reference number, IEC : Replace the fifth dashed paragraph with the following: - manufacturer s or responsible company s name or trade-mark or identification mark; In the second paragraph, add or JIS C 8303:2007 after the reference number, IEC/TR 60083: F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 28 of 50 National Differences IEC st ed.

127 Clause Requirement - Test Result - Remark Verdict 1.7.5A Add the following new clause after A Appliance Couplers If an appliance coupler according to IEC , C.14(rated current: 10 A) is used in equipment whose rated voltage is less than 125 V and the rated current is over 10 A, the following instruction or equivalent shall be described in the user instruction. Use only designated cord set attached in this equipment Replace first sentence with the following: Instructions and equipment marking related to safety shall be in Japanese A Add the following new clause after A Marking for CLASS 0I EQUIPMENT For CLASS 0I EQUIPMENT, the following instruction shall be marked on the visible place of the mains plug or the main body: Provide an earthing connection Moreover, for CLASS 0I EQUIPMENT, the following or equivalent instruction shall be indicated on the visible place of the main body or written in the operating instructions: Provide an earthing connection before the mains plug is connected to the mains. And, when disconnecting the earthing connection, be sure to disconnect after pulling out the mains plug from the mains In item b) of this sub-clause, replace IEC with JIS C 8303:2007 or Article 1 of the Ministerial Ordinance (No. 85:1962) Add the following after the first paragraph. This also applies to the conductor of lead wire for protective earthing of CLASS 0I EQUIPMENT. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 29 of 50 National Differences IEC st ed.

128 Clause Requirement - Test Result - Remark Verdict Replace the first paragraph with the following. Equipment required to have protective earthing shall have a main protective earthing terminal. For equipment with a DETACHABLE POWER SUPPLY CORD, the earthing terminal in the appliance inlet is regarded as the main protective earthing terminal except for CLASS 0I EQUIPMENT providing separate main protective earthing terminal other than appliance inlet Replace the first sentence with the following. Protective earthing connections of CLASS I EQUIPMENT shall make earlier and break later than the supply connections in each of the following: A Add the following new clause after A Earthing of CLASS 0I EQUIPMENT Plugs with a lead wire for earthing shall not be used for equipment having a rated voltage exceeding 150 V. For plugs with a lead wire for earthing, the lead wire shall not be earthed by a clip. CLASS 0I EQUIPMENT shall be provided with an earthing terminal or a lead wire for earthing in the external location where easily visible In this sub-clause, replace IEC with JIS C 0664: In the second paragraph, replace IEC with JIS C 0664: Add the following after Table 3A: Table 3A applies when cables complying with JIS C 3662 or JIS C 3663 are used. In case of other cables, the cable entries shall be so designed that a conduit suitable for the cable used can be fitted. No such cord or cable is provided. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 30 of 50 National Differences IEC st ed.

129 Clause Requirement - Test Result - Remark Verdict Add the following to the last of first dashed paragraph. Or mains cords shall be of the sheathed type complying with Appendix 1 of Article 1 of the Ministerial Ordinance (No. 85:1962) on stipulating technical requirements for the Electrical Appliance. Add the following to the last of second dashed paragraph. Or mains cords shall be of the sheathed type complying with Appendix 1 of Article 1 of the Ministerial Ordinance (No. 85:1962) on stipulating technical requirements for the Electrical Appliance. Delete 1) in Table 3B Add the following note to Table 3D: NOTE For cables other than those complying with JIS C 3662 or JIS C 3663, terminals shall be suitable for the size of the intended cables Add the following after the first sentence: This requirement is not applicable to the external earting terminal of Class 0I equipment Add the following after the first sentence: This requirement also applies to those connections in Class 0I equipment, where CLEARANCE or CREEPAGE DISTANCES over BASIC INSULATION would be reduced to less than the values specified in Replace the first paragraph with the following: Except as permitted below, equipment shall be classified and labelled according to JIS C 6802:2005, and JIS C 6803:2006 or IEC :2000, as applicable. Replace IEC in the second and the last paragraph with JIS C 6802: Add the following NOTE to Table 4B, 3): NOTE: In case no data for the material is available, Appendix 4, 4. (1). b. 3 of the Interpretation on the Ministerial Ordinance stipulating Technical Specifications for Electrical Appliances (Commerce and Distribution Policy Group No. 3:2008/06/19) may apply. No such cord or cable is provided Ditto. The equipment does not generate x-radiation or uses a laser. Added. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 31 of 50 National Differences IEC st ed.

130 Clause Requirement - Test Result - Remark Verdict Add a note after the first paragraph as follows: NOTE Attention should be drawn to that majority of three-phase power system in Japan is of delta connection, and therefore, in that case, the test is conducted using the test circuit from IEC 60990, figure Replace Table 5A as follows: Type of equipment All equipment HAND-HELD MOVABLE (other than HAND-HELD, but including TRANSPORTABLE EQUIPMENT STATIONARY, PLUGGABLE TYPE A Terminal A of measuring instrument connected to: Accessible parts and circuits not connected to protective earth Equipment main protective earthing terminal (if any) CLASS I EQUIPMENT Maximum TOUCH CURRENT ma r.m.s. 1) Maximum PROTECTIVE CONDUCTOR CURRENT 0,25-0,75-3,5-3,5 - All other STATIONARY EQUIPMENT - not subject to the conditions of subject to the conditions 3, % of input current of HAND-HELD Equipment main protective 0,5 - Others earthing terminal (if any) CLASS 0I EQUIPMENT 1,0-1) If peak values of TOUCH-CURRENT are measured, the maximum values obtained by multiplying the r.m.s. values by 1, Replace IEC in NOTE 4 with JIS C Replace IEC in NOTE 3 with JIS C 0664: F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 32 of 50 National Differences IEC st ed.

131 Clause Requirement - Test Result - Remark Verdict 7.2 Add the following after the paragraph: However, the separation requirements and tests of a), b) and c) do not apply to a CABLE DISTRIBUTION SYSTEM if all of the following apply: - the circuit under consideration is a TNV-1 CIRCUIT; and the common or earthed side of the circuit is connected to the screen of the coaxial cable and to all accessible parts and circuits (SELV, accessible metal parts and LIMITED CURRENT CIRCUITS, if any); and the screen of the coaxial cable is intended to be connected to earth in the building installation. W.1 Replace the second and the third sentence in the first paragraph with the following: This distinction between earthed and unearthed (floating) circuit is not the same as between CLASS I EQUIMENT, CLASS 0I EQUIPMENT and CLASS II EQUIPMENT. Floating circuits can exist in CLASS I EQUIPMENT or CLASS 0I EQUIPMENT and earthed circuits in CLASS II EQUIPMENT. No TNV circuit. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 33 of 50 National Differences IEC st ed.

132 Clause Requirement - Test Result - Remark Verdict Annex JA Add a new annex JA with the following contents. Annex JA (normative) Document shredding machines Document shredding machines shall also comply with the requirements of this annex except those of STATIONARY EQUIPMENT used by connecting directly to an AC MAINS SUPPLY of three-phase 200V or more. JA.1 Markings and instructions The symbol (JIS S 0101:2000, 6.2.4) and the following precautions for use shall be marked on readily visible part adjacent to document feed opening. The marking shall be clearly legible, permanent, and easily discernible; - that use by an infants/children may cause a hazard of injury etc.; - that a hand can be drawn into the mechanical section for shredding when touching the document-slot; - that clothing can be drawn into the mechanical section for shredding when touching the document-slot; - that hairs can be drawn into the mechanical section for shredding when touching the document-slot; - in case of equipment incorporating a commutator motor, that equipment may catch fire or explode by spraying of flammable gas. JA.2 Inadvertent reactivation Any safety interlock that can be operated by means of the test finger, Figure JA.1, is considered to be likely to cause inadvertent reactivation of the hazard. Compliance is checked by inspection and, where necessary, by a test with the test finger, Figure JA.1 JA.3 Disconnection from the mains supply Document shredding machines shall incorporate an isolating switch complying with sub-clause as the device disconnecting the power of hazardous moving parts. For this switch, two-position (single-use) switch or multi-position (multifunction) switch (e.g., slide switch) may be used. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 34 of 50 National Differences IEC st ed.

133 Clause Requirement - Test Result - Remark Verdict Annex JA If two-position switch, the positions for ON and OFF shall be indicated in accordance with sub-clause If multi-position switch, the position for OFF shall be indicated in accordance with sub-clause and other positions shall be indicated with proper terms or symbols. Compliance is checked by inspection JA.4 Protection against hazardous moving parts Any warning shall not be used instead of the structure for preventing access to hazardous moving parts. Document shredding machines shall comply with the following requirements. Insert the test finger, Figure JA.1, into all openings in MECHANICAL ENCLOSURES without applying appreciable force. It shall not be possible to touch hazardous moving parts with the test finger. This consideration applies to all sides of MECHANICAL ENCLOSURES when the equipment is mounted as intended. Before testing with the test finger, remove the parts detachable without a tool. Insert the wedge-probe, Figure JA.2, into the document-slot. And, against all directions of openings, if straight-cutting type, a force of 45 N shall apply to the probe, and 90 N if crosscutting type. In this case, the weight of the probe is to be factored into the overall applied force. Before testing with the wedge-probe, remove the parts detachable without a tool. It shall not be possible to touch any hazardous moving parts, including the shredding roller or the mechanical section for shedding, with the probe. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 35 of 50 National Differences IEC st ed.

134 Clause Requirement - Test Result - Remark Verdict Annex JA Figure JA.1 Test finger 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 36 of 50 National Differences IEC st ed.

135 Clause Requirement - Test Result - Remark Verdict Annex JA Details of the tip of wedge Distance from the tip (mm) Thickness of probe (mm) NOTE 1 The thickness of the probe varies linearly, with slope changes at the respective points shown in the table. NOTE2 The allowable dimensional tolerance of the probe is +/ mm. Figure JA.2 Wedge-probe 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 37 of 50 National Differences IEC st ed.

136 Clause Requirement - Test Result - Remark Verdict Korea (KR) National standard reference.: K Addition Plugs for the connection of the apparatus to the supply mains shall comply with the Korean requirement (KSC 8305 and 8305). 7 EMC Addition The apparatus shall comply with the relevant CISPR standards Must be considered before marketed in Korea. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 38 of 50 National Differences IEC st ed.

137 Clause Requirement - Test Result - Remark Verdict Sweden (SE) National standard reference.: SS-EN The following text is added: NOTE - In Sweden the following text is added between the first and second paragraph: In Sweden, if this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that clearances and creepage distances do not exist, if the component passes the electric strength test in the accordance with the compliance clause below and in addition: - passes the test and inspection criteria of IEC , with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of IEC , shall be performed using 1,5 kv); and - is subject to routine testing for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with IEC :1993, subclass Y2. A capacitor classified Y3 according to IEC :1993, may bridge this insulation under the following conditions: The insulation requirements are satisfied by having a capacitor classified Y3 as defined by IEC , which in addition to the Y3 testing, is tested with an Impulse test of 2.5kV defined in IEC , subclause The additional testing shall be performed on all the test specimens as described in IEC The Impulse test of 2.5kV is to be performed before the Endurance Test in IEC in the sequence of tests as described in IEC No TNV circuits. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 39 of 50 National Differences IEC st ed.

138 Clause Requirement - Test Result - Remark Verdict Switzerland (CH) National standard reference.: SN EN : Ordinance on environmentally hazardous substances SR , Annex 1.7, Mercury - Annex 1.7 of SR applies for mercury. Switches containing mercury such as thermostats, relays and level controllers are not allowed Ordinance on chemical hazardous risk reduction SR , Annex 2.15 Batteries Annex 2.15 of SR applies for batteries containing cadmium and mercury. Note: Ordinance relating to environmentally hazardous substances, SR of is not longer in force and superseded by SR of (ChemRRV). No switch. The battery containing cadmium and mercury should be evaluated before marketing into Switzerland. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 40 of 50 National Differences IEC st ed.

139 Clause Requirement - Test Result - Remark Verdict 3.2 Supply cords of portable electrical appliances having a rated current not exceeding 10 A shall be provided with a plug complying with IEC (3.ed.) + am1, SEV 1011 and one of the following dimension sheets: - SEV :2009 Plug type 11, L + N, 250V 10A - SEV :2009 Plug type 12, L + N + PE, 250V 10A - SEV :2009 Plug type 15, 3L + N + PE, 250/400V 10A Supply cords of portable electrical appliances having a rated current not exceeding 16 A shall be provided with a plug complying with IEC (3.ed.) + am1, SEV 1011 and one of the following dimension sheets: - SEV :2009 Plug type 21 L + N, 250 V, 16A - SEV :2009 Plug type 23 L + N + PE, 250 V, 16A - SEV :2009 Plug type 25 3L + N + PE, 250/400V 16A NOTE 16 A plugs are not often used in Swiss domestic installation system. See TRF template regulatory requirements Switzerland on IECEE Website R.R. TRF templates. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 41 of 50 National Differences IEC st ed.

140 Clause Requirement - Test Result - Remark Verdict USA (US) National standard reference.: SN EN : Equipment able to be installed in accordance with the National Electrical Code ANSI/NFPA Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded Special requirements apply to equipment intended for use outdoors For Pluggable Equipment Type A, the protection in the installation is assumed to be 20 A All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of UL component standards in Annex P All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of UL component standards (A. P.2.) Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like For other than limited power and TNV circuits, the type of output circuit identified for output connector External cable assemblies that exceed 3.05 m in length to be types specified in the National Electrical Code Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope Telephone line and extension cords and the like comply with UL Equipment intended for connection to a d.c. power (mains) distribution system is subject to special circuit classification requirements (e.g., TNV-2) See last page. No intended to for use outdoors. Replaced. Replaced. No such cord or cable is provided. No such cord or cable is provided. No such cord or cable is provided. Not apply for Not apply for 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 42 of 50 National Differences IEC st ed.

141 Clause Requirement - Test Result - Remark Verdict Earthing of d.c. powered equipment provided 1.7 Lamp replacement information indicated on lampholder in operator access area Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor Equipment voltage rating not higher than rating of the plug except under special conditions Special fuse replacement marking for operator accessible fuses Identification of terminal connection of the equipment earthing conductor Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used Marking located adjacent to terminals and visible during wiring Screw shell of Edison-base lampholder tied to the neutral conductor Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover b b b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M.4 For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 ma peak or 30 ma d.c. under normal conditions Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and routine testing In the event of a single fault, the limits of apply to SELV circuits and accessible conductive parts No such fuse used. Not apply for. No TNV circuits. No TNV circuits. No TNV circuits. No TNV circuits. No TNV circuits. No TNV circuits. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 43 of 50 National Differences IEC st ed.

142 Clause Requirement - Test Result - Remark Verdict 2.5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with higher rated devices, if operator replaceable 2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth For Pluggable Equipment Type A, if neither a) or b) are applicable, the current rating of the circuit is taken as 20 A Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US Data for selection of special external branch circuit overcurrent devices marked on the equipment Standard supply outlets protected by overcurrent device in accordance with the National Electrical Code Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring Additional requirements for overcurrent protection apply to equipment provided with panelboards Non-motor-operated equipment requiring special overcurrent protective device marked with device rating Multi-layer winding wire subject to UL component wire requirements in addition to and Annex U Permissible combinations of internal wiring/external cable sizes for overcurrent and short circuit protection All interconnecting cables protected against overcurrent and short circuit. 3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the National Electrical Code No such fuse used. No interconnecting cables Permitted use for flexible cords and plugs. No such cord or cable is provided Flexible cords provided with attachment plug rated 125% of equipment current rating. No such cord or cable is provided. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 44 of 50 National Differences IEC st ed.

143 Clause Requirement - Test Result - Remark Verdict Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord) Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the National Electrical Code Permanently connected equipment may have terminals or leads not smaller than No. 18 AWG (0.82 mm²) and not less than 152 mm in length for connection of field installed wiring If supply wires exceed 60 C, marking indicates use of 75 C or 90 C wiring for supply connection as appropriate Equipment compatible with suitable trade sizes of conduits and cables Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation Conductors in power supply cords sized according to National Electrical Code Power supply cords and cord sets incorporate flexible cords suitable for the particular application. The equipment is not for connected to a D.C. mains supply. Ditto. Ditto. Ditto. Ditto. Ditto. No such cord or cable is provided. Ditto. Ditto. Ditto. Ditto. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 45 of 50 National Differences IEC st ed.

144 Clause Requirement - Test Result - Remark Verdict Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source Adequate wire bending space and volume of field wiring compartment required to properly make the field connections Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse. 3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm²) or smaller conductor if provided with upturned lugs, cupped washer or equivalent retention Terminals accept wire sizes (gauge) used in the United States Terminals accept current-carrying conductors rated 125% of the equipment current rating Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads Separate motor control device(s) required for cord-connected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V Vertically mounted disconnect devices oriented so up position of handle is "on" For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means. No such cord or cable is provided. No motor in the equipment. No such device is used for equipment. Equipment not with battery systems. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 46 of 50 National Differences IEC st ed.

145 Clause Requirement - Test Result - Remark Verdict Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more Compartment housing high-pressure lamp marked to indicate risk of explosion Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit In addition to the IEC requirements, Direct Plugin Equipment complies with UL 1310 mechanical assembly requirements The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30 (Table NAE.6) Equipment using replenishable liquids marked to indicate type of liquid to be used Equipment that produces x-radiation and does not comply with under all conditions of servicing marked to indicate the presence of radiation where readily visible Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040). 4.7 Automated information storage equipment intended to contain more than 0.76 mm³ of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system Equipment for use in environmental air space other than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL Equipment for installation in space used for environmental air as described in Sec (c) of the NEC provided with instructions indicating suitability for installation in such locations Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m² or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications Wire marked "VW-1" or "FT-1" considered equivalent Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections. Not appliance of CRT in the equipment. No high-pressure lamp. Not apply for. No direct plug-in equipment. Not apply for. Not apply for. The equipment does not generate x-radiation or uses a laser. Ditto.. Such condition is not considered. Ditto. Ditto. No connection to the TELECOMMUNICATION NETWORK. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 47 of 50 National Differences IEC st ed.

146 Clause Requirement - Test Result - Remark Verdict Touch current due to ringing voltage for equipment containing telecommunication network leads Overloading of SELV connectors and printed wiring board receptacles accessible to the operator Tests interrupted by opening of a component repeated two additional times Test interrupted by opening of wire or trace subject to certain conditions. 6 Specialized instructions provided for telephones that may be connected to a telecommunications network. 6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network Special requirements for enameled wiring used as electrical separation provided between parts connected to telecommunication network and telecommunication circuitry intentionally isolated from network Digital line termination equipment (e.g., NCTE) subject to separation requirements. 6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection. 6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable. 6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C). 6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions. 6.5 Acoustic pressure from an ear piece less than 136 dba for short duration disturbances, and less than 125 dba for handsets, 118 dba for headsets, and 121 dba for insert earphones, for long duration disturbances. 7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the National Electrical Code No connection to the TELECOMMUNICATION NETWORK. No SELV connectors. No connection to the TELECOMMUNICATION NETWORK. Ditto. Ditto. Ditto. Ditto. Ditto. Ditto. Ditto. Not apply for. Not direct connection to cable distribution system. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 48 of 50 National Differences IEC st ed.

147 Clause Requirement - Test Result - Remark Verdict H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations. M.4 Special requirements for message waiting and similar telecommunications signals. NAC NAC Equipment intended for use with a generic secondary protector marked with suitable instructions. Equipment intended for use with a specific primary or secondary protector marked with suitable instructions. No ionizing radiation. No TNV circuits. No TNV circuits. Not apply for. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 49 of 50 National Differences IEC st ed.

148 Note: Before placing the products in the different countries, the manufacturer must ensure that: 1. Operating Instructions, Ratings Labels and Warnings Labels written in an Accepted or Official Language of the country in question. 2. The equipment complies with the National Standards and/or Electrical Codes of the country in question. 7F., No. 37, Sec. 2, Zhongyang S., Rd., V-U0028 dev No. 2.DOC Beitou District, Taipei City, 11270, Taiwan. Page 50 of 50 National Differences IEC st ed.

149 Attachment No. 3 Page 1 of 2 The above labels are drafts of an artwork for marking plate pending approval by National Certification Bodies and they shall not be affixed to products prior to such an approval

150 Attachment No. 3 Page 2 of 2 The above labels are drafts of an artwork for marking plate pending approval by National Certification Bodies and they shall not be affixed to products prior to such an approval

151 Attachment No. 4 Page 1 of 3 Type Designation: V-U0028 Report Number: Overall View

152 Attachment No. 4 Page 2 of 3 Type Designation: V-U0028 Report Number: Internal View

153 Attachment No. 4 Page 3 of 3 Type Designation: V-U0028 Report Number: Main board

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 55 Report No.:L611332L009 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009.

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009. ELECTRICAL TESTING 839.01 Hermon Laboratories Ltd. Tel.+972 4 628 8001 Fax.+972 4 628 8277 SAFETY TEST REPORT ACCORDING TO: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, IEC 60950-1:2005 (Second Edition)

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 248792 Date of issue... : 2013-11-25

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 46 TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 160414015SZN-002 Date of issue... : May 09, 2016 Total number of pages... : 77 pages Applicant

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements Page 1 of 49 Report Reference No....: 81790 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2009 TEST REPORT :2006 Information technology equipment Safety Part 1: General

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

A Test Lab Techno Corp.

A Test Lab Techno Corp. Report No. 1607CF12 age 1 of 52 TEST REORT AS/NZS60950.1:2011+A1:2013 Safety of Information Technology Equipment including Electrical business equipment Report Number.... : 1607CF12 Date of issue... :

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: GLOBAL ADVANTAGE INTERNATIONAL TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: T223-0035/16 Date of issue...: 2016-02-01

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2011-01-12 Page 1 of 1 Report Reference # ASL10120310 COVER PAGE FOR TEST REPORT Test Item Description: Notebook PC Model/Type Reference: MS-16Y1 Rating(s): 19Vdc, 3.42A or 19Vdc, 4.74A Standards:

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2006-05-11 Page 1 of 2 Report Reference # E212360-A19-UL-1 Amendment 2 2009-07-03 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference:

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1712057S.50A Date of issue... : 2017-04-13 Total number

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :

More information

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences:

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences: age 3 of 106 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. re-production samples without serial

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2008-11-11 Page 1 of 2 Report Reference # E186249-A82-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No.... : Complied by (+ signature)... : 1205S019S

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 72 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements age 1 of 49 Report Reference No....: 80983 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2008 TEST REORT :2006 Information technology equipment Safety art 1: General

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....:

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number.... : TEST REORT Information technology equipment Safety art 1: General requirements Date of issue... : 7 March, 2017 Total number of pages...

More information

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT. IEC 62133: 2012 (Second Edition) Test Report issued under the responsibility of: TEST REORT, Second Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of GUAGDOG EAST OWER CO., LTD. Uninterruptible ower Supply Model(s): EA99300,EA99250,EA99200 repared For : GUAGDOG EAST OWER CO., LTD. o.6 orthern Industry

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

Test Report issued under the responsibility of: Report Number...:

Test Report issued under the responsibility of: Report Number...: Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : 251006 2345690 (-2502294) Date of issue...

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

Test Report issued under the responsibility of: BA-10CA08002-K-1 Date of issue... : Total number of pages Report Reference No...

Test Report issued under the responsibility of: BA-10CA08002-K-1 Date of issue... : Total number of pages Report Reference No... Test Report issued under the responsibility of: TEST REPORT IEC 62133, First Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-07-30 Page 1 of 6 Report Reference # E313912-A35-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A Ratings...: age 2 of 41 Report o.: CTL1607012503-WS Adapter: Input: 100-240Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A age 3 of 41 Report o.: CTL1607012503-WS Summary of testing: Testing

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 11 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS

More information

Copy of marking plate. Page 2 of 50 Report No. TRS

Copy of marking plate. Page 2 of 50 Report No. TRS Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-01-23 Page 4 of 57 Report Reference # E116994-A34-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

Audio/video, information and communication technology equipment Part 1: Safety requirements

Audio/video, information and communication technology equipment Part 1: Safety requirements Test Report issued under the responsibility of: TEST REORT Audio/video, information and communication technology equipment art 1: Safety requirements Report Number... : 151101256SHA-001 Date of issue...

More information