COVER PAGE FOR TEST REPORT

Size: px
Start display at page:

Download "COVER PAGE FOR TEST REPORT"

Transcription

1 Issue Date: Page 1 of 2 Report Reference # E A82-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ2, QQGQ8 Component Recognition Switching Power supply for building-in DS DS DS : Input : Vac; 50/60Hz 20.0A Max. Output : +12.0V, 240A Max; +3.3Vsb, 3A Max DS2900-3: Input : Vac; 50/60Hz 16A Output : +12.0V, 240A Max; +3.3Vsb, 3A Max Standards: UL , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) Applicant Name and Address: ASTEC INTERNATIONAL LIMITED - PHILIPPINE BRANCH 3RD & 4TH FLOOR TECHNO PLAZA ONE BLDG. #18 ORCHARD ROAD, EASTWOOD CITY CYBERPARK, BAGUMBAYAN, QUEZON CITY 1110 PHILIPPINES This Report includes the following parts, in addition to this cover page: 1. Specific Inspection Criteria 2. Specific Technical Criteria 3. Clause Verdicts 4. Critical Components 5. Test Results 6. National Differences 7. Enclosures Copyright 2008

2 Issue Date: Page 2 of 2 Report Reference # E A82-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. Test Report By: Reviewed By: Steve Chiu Associate Project Engineer UL International Limited Brian Wong Associate Project Engineer UL International Limited Copyright 2008

3 Issue Date: Page 1 of 63 Report Reference # E A82-UL-1 SPECIFIC INSPECTION CRITERIA BA1.0 BA1.1 Special Instructions to UL Representative BB1.0 BB1.1 Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. BC1.0 BC1.1 BC1.2 Markings and instructions The following markings and instructions are provided as indicated. All clause references are from UL , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements). Standard Clause Title Clause Power rating - Ratings Power rating - Company identification Power rating - Model Marking or Instruction Details Ratings (voltage, frequency/dc, current) Listee's or Recognized company's name, Trade Name, Trademark or File Number Model Number Fuses - Rating Rated current and voltage and type located on or adjacent to fuse or fuseholder.

4 Issue Date: Page 2 of 63 Report Reference # E A82-UL-1 BD1.0 BD1.1 BD1.2 BD1.3 BD1.4 Production-Line Testing Requirements Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information. Test Potential Model Component Removable Parts Test probe location Earthing Continuity Test Exemptions - This test is not required for the following models: Electric Strength Test Exemptions - This test is not required for the following models: Electric Strength Test Component Exemptions - The following solid-state components may be disconnected from the remainder of the circuitry during the performance of this test: V rms V dc Test Time, s BE1.0 BE1.1 Sample and Test Specifics for Follow-Up Tests at UL Model Component Material Test Sample(s) Test Specifics

5 Issue Date: Page 3 of 63 Report Reference # E A82-UL-1 SPECIFIC TECHNICAL CRITERIA UL , First Edition Information technology equipment - Safety- Part 1: General Requirements Report Reference No...: E A82-UL-1 Compiled by...: Steve Chiu Reviewed by...: Brian Wong Date of issue...: Standards...: UL , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure...: Component Recognition Non-standard test method...: Test item description...: Switching Power supply for building-in Trademark...: Model and/or type reference...: DS DS Rating(s)...: DS : Input : Vac; 50/60Hz 20.0A Max. Output : +12.0V, 240A Max; +3.3Vsb, 3A Max DS2900-3: Input : Vac; 50/60Hz 16A Output : +12.0V, 240A Max; +3.3Vsb, 3A Max Particulars: test item vs. test requirements Equipment mobility...: for building-in Operating condition...: continuous Mains supply tolerance (%)...: +10%, -10% Tested for IT power systems...: No IT testing, phase-phase voltage (V)...: Class of equipment...: Class I (earthed) Mass of equipment (kg)...: < 18 Protection against ingress of water...: IP X0

6 Issue Date: Page 4 of 63 Report Reference # E A82-UL-1 Possible test case verdicts: - test case does not apply to the test object...: N / A - test object does meet the requirement...: - test object does not meet the requirement...: Fail (acceptable only if a corresponding, less stringent national requirement is "") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

7 Issue Date: Page 5 of 63 Report Reference # E A82-UL-1 GENERAL PRODUCT INFORMATION: CA1.0 CA1.1 Report Summary CB1.0 CB1.1 Product Description Class I Power supply for building-in CC1.0 CC1.1 Model Differences Model DS is identical to model DS except for model designation, input current rating, fan airflow direction and base chassis/fan grill construction. CD1.0 CD1.1 Additional Information The label is a draft of an artwork for marking plate pending approval by National Cartification Bodies and it shall not be affixed to products prior to such an approval. CE1.0 CE1.2 CE1.4 CE1.5 CE1.6 Technical Considerations The product was submitted and tested for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 50 C, The product is intended for use on the following power systems: TN, TT The equipment disconnect device is considered to be: provided at end system. The class of laser product is: Class 1 (I) CE1.7 The product was investigated to the following additional standards: EN : A11:2004 (which includes all European national differences, including those specified in this test report). CE1.12 The following were investigated as part of the protective earthing/bonding: Printed wiring board trace (refer to Enclosure - Schematics + PWB for layouts) CE1.14 The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual CE2.0 General - The unit is for use in product where the acceptability of the combination is determined by Both USR and CNR indicate investigation to the Standard for Safety of Information Technology Equipment, UL , First Edition, including revisions through revision date October 31, 2007 and CAN/CSA-C22.2 No , First Edition including revisions through revision data July 7, CE2.1 The Clearances and Creepage Distances have additionally been assessed for suitability up to 3048 m or ft elevation. CF1.0 CF1.1 Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by

8 Issue Date: Page 6 of 63 Report Reference # E A82-UL-1 CF1.2 CF1.3 CF1.5 When installed in an end-product, consideration must be given to the following: The following Production-Line tests are conducted for this product: Electric Strength, Earthing Continuity The end-product Electric Strength Test is to be based upon a maximum working voltage of: Primary-SELV: Vrms, 640 Vpk, Primary-Earthed Dead Metal: 384Vrms, 648 Vpk The following secondary output circuits are SELV: +12V, 3.3Vsb CF1.6 The following secondary output circuits are at hazardous energy levels: +12V CF1.7 CF1.11 CF1.12 The following secondary output circuits are at non-hazardous energy levels: +3.3Vsb The power supply terminals and/or connectors are: Not investigated for field wiring The maximum investigated branch circuit rating is: 30 A CF1.13 The investigated Pollution Degree is: 2 CF1.15 CF1.16 CF1.18 CF1.19 CF1.23 CF2.0 CF2.1 CF2.2 Proper bonding to the end-product main protective earthing termination is: Required An investigation of the protective bonding terminals has: Been conducted The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation system with the indicated rating greater than Class A (105 C): T105 and T103 (Class F) The following end-product enclosures are required: Mechanical, Fire, Electrical The equipment is suitable for direct connection to: AC mains supply This power supply was not evaluated for end system mounting. When installed in the end system, the proper evaluation should be considered., This power supply has a secondary output (+12.0 V) exceeding 240 VA. When installing into the end system, care must be taken that this secondary output and the appropriate wires may not be touched. This equipment was not evaluated for end system mounting. When installed in the end system, the proper evaluation should be considered.

9 Issue Date: Page 7 of 63 Report Reference # E A82-UL-1 1 GENERAL 1.5 Components General Comply with IEC or relevant component standard (see appended table 1.5.1) Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this standard. Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC and the relevant component standard. Components, for which no relevant IEC-standard exists, have been tested under the conditions occurring in the equipment, using applicable parts of IEC Thermal controls No thermal controls Transformers Transformers used are suitable for their intended applications and comply with relevant parts of this standard and particularly Annex C, see Annex C - Transformers Interconnecting cables No interconnecting cables Capacitors in primary circuits... : Line to Line capacitors are subclass X1 or X2. Primary-to earth capacitors are subclass Y1 or Y Double insulation or reinforced insulation bridged by components General Bridging capacitors Bridging resistors Accessible parts Components in equipment for IT power systems

10 Issue Date: Page 8 of 63 Report Reference # E A82-UL Power interface AC power distribution systems Input current (see appended table 1.6.2) Voltage limit of hand-held equipment Neutral conductor Neutral is insulated from earth with basic insulation throughout the equipment.

11 Issue Date: Page 9 of 63 Report Reference # E A82-UL Marking and instructions Power rating The required marking is readily visible in Operator access area. Rated voltage(s) or voltage range(s) (V)... : V AC Symbol for nature of supply, for d.c. only... : Rated frequency or rated frequency range (Hz)... : 50/60 Rated current (ma or A)... : DS : 20.0 A MAX DS : 16.0 A Manufacturer's name or trademark or identification mark... : ASTEC/EMERSON Type/model or type reference... : DS , DS Symbol for Class II equipment only... : Other symbols... : The additional marking does not give rise to misunderstandings Certification marks... : Refer to Model Label Safety instructions Installation instruction are available to the user Short duty cycles The equipment is intended for continuous operation Supply voltage adjustment... : No voltage selector Power outlets on the equipment... : No standard power outlet Fuse identification... : PCB marked F25A, 250 V beside F Wiring terminals Protective earthing and bonding terminals... : Terminal for connection of protective earthing conductor is marked with standard earth symbol (IEC No. 5019) near the terminal Terminal for a.c. mains supply conductors Equipment for building in. Must be checked in the end system Terminals for d.c. mains supply conductors Controls and indicators Refer below: Identification, location and marking... : The function of controls affecting safety is obvious

12 Issue Date: Page 10 of 63 Report Reference # E A82-UL-1 without knowledge of language etc Colours... : For functional indication a LED lights when the equipment is operating Symbols according to IEC : There are no switches in the equipment Markings using figures... : No controls Isolation of multiple power sources... : Only one connection supplying hazardous voltages and energy levels to the equipment IT power distribution systems Equipment evaluated for TN power source only Thermostats and other regulating devices No thermostats or other regulating devices Language... : Instructions and markings shall be in a language acceptable for the country where the equipment is to be used Durability The marking withstands required tests Removable parts No removable parts Replaceable batteries Language... : Instructions and markings shall be in a language acceptable for the country where the equipment is to be used Operator access with a tool... : All areas containing hazard(s) are inaccessible to the operator Equipment for restricted access locations... : Equipment not intended for installation in RAL. - -

13 Issue Date: Page 11 of 63 Report Reference # E A82-UL-1 2 PROTECTION FROM HAZARDS 2.1 Protection from electric shock and energy hazards Protection in operator access areas Access to energized parts Energized parts are not accessible. Checked by test finger, test probe and test pin. Test by inspection... : Consider at end system. Test with test finger... : Consider at end system. Test with test pin... : Consider at end system. Test with test probe... : No TNV present Battery compartments... : No Battery Access to ELV wiring No internal wiring at ELV Working voltage (V); minimum distance (mm) through insulation... : (see appended table ) Access to hazardous voltage circuit wiring All accessible parts are separated from internal wiring at hazardous voltage by double or reinforced insulation, complying with and Energy hazards... : The output from the power supply represents an energy hazard. No operator access permitted Manual controls No shafts of knobs etc Discharge of capacitors in equipment The capacitance of the input circuit is > 0,1*F. The measurements were performed in worst case condition with regard to the fuse. Time-constant (s); measured voltage (V)... : 8V after 1 sec Protection in service access areas Protection in restricted access locations

14 Issue Date: Page 12 of 63 Report Reference # E A82-UL SELV circuits General requirements SELV circuits overate at or below 42.4 Vpk or 60 Vdc under normal and single fault conditions Voltages under normal conditions (V)... : All accessible voltages are less than 42.4 Vp or 60 V dc and are classified as SELV Voltages under fault conditions (V)... : Under fault conditions voltages never exceed 71V peak and 120Vdc and do not exceed 42.4V peak or 60V dc for more than 0.2 sec. Voltages did not exceed 71V peak and 120Vdc and did not exceed 42.4V peak or 60V dc for more than 0.2 sec Separation by double insulation or reinforced insulation (method 1) Separation by earthed screen (method 2) Protection by earthing of the SELV circuit (method 3) Connection of SELV circuits to other circuits... : The SELV circuits are not connected to other circuits other than protective earth 2.3 TNV circuits Limits No TNV Circuit Type of TNV circuits... : Separation from other circuits and from accessible parts Insulation employed... : Separation from hazardous voltages Insulation employed... : Connection of TNV circuits to other circuits Insulation employed... : Test for operating voltages generated externally

15 Issue Date: Page 13 of 63 Report Reference # E A82-UL Limited current circuits General requirements Limit values Frequency (Hz)... : - Measured current (ma)... : - Measured voltage (V)... : - Measured capacitance (mf)... : Connection of limited current circuits to other circuits 2.5 Limited power sources Inherently limited output Impedance limited output Overcurrent protective device limited output Regulating network limited output under normal operating and single fault condition Regulating network limited output under normal operating conditions and overcurrent protective device limited output under single fault condition Output voltage (V), output current (A), apparent - power (VA):... : Current rating of overcurrent protective device (A) : -

16 Issue Date: Page 14 of 63 Report Reference # E A82-UL Provisions for earthing and bonding Protective earthing Accessible conductive parts are reliably connected to protective earth Functional earthing Functional earthing is separated from hazardous voltages by basic insulation and protective earth Protective earthing and protective bonding conductors General Size of protective earthing conductors Power supply cord not provided with the equipment. Must be considered in endsystem. Rated current (A), cross-sectional area (mm2), - AWG... : Size of protective bonding conductors Comply Rated current (A), cross-sectional area (mm2), AWG... : Resistance (Ohm) of earthing conductors and their terminations, test current (A)... : 20A for DS ; 16A for DS See V, 40A Colour of insulation... : Terminals General Protective earthing and bonding terminals Rated current (A), type and nominal thread - diameter (mm)... : Separation of the protective earthing conductor from protective bonding conductors Integrity of protective earthing Interconnection of equipment No interconnection of equipment Components in protective earthing conductors and protective bonding conductors There are no switches or overcurrent protective devices in the protective earthing / bonding conductors Disconnection of protective earth It is not possible to disconnect protective earth without -

17 Issue Date: Page 15 of 63 Report Reference # E A82-UL-1 disconnecting mains Parts that can be removed by an operator No operator removable parts with protective earthing Parts removed during servicing Protective earthed parts cannot be removed in a way which impair safety Corrosion resistance Screws for protective bonding Metal thickness at least twice the pitch of the screw Reliance on telecommunication network or cable distribution system 2.7 Overcurrent and earth fault protection in primary circuits Basic requirements Protective devices are integrated in the equipment, see also Sub-clause 5.3. Instructions when protection relies on building installation Faults not covered in Short-circuit backup protection Number and location of protective devices... : One located in Live line Protection by several devices See Sub-clause Warning to service personnel... : See Sub-clause

18 Issue Date: Page 16 of 63 Report Reference # E A82-UL Safety interlocks General principles No Safety Interlock Switch Protection requirements Inadvertent reactivation Fail-safe operation Moving parts Overriding Switches and relays Contact gaps (mm)... : Overload test Endurance test Electric strength test Mechanical actuators 2.9 Electrical insulation Properties of insulating materials Neither natural rubber, materials containing asbestos nor hygroscopic materials are used as insulation. No driving belts or couplings used Humidity conditioning Humidity treatment performed for 48h Humidity (%)... : 91-95% - Temperature ( C)... : 20-30*C Grade of insulation Insulation is considered to be functional, basic, supplementary, reinforced or double insulation.

19 Issue Date: Page 17 of 63 Report Reference # E A82-UL Clearances, creepage distances and distances through insulation General Determination of working voltage Clearances See appended table General Refer below: Clearances in primary circuit (see appended table and ) Clearances in secondary circuits Only functional insulation in secondary circuits, ref Measurement of transient voltage levels Creepage distances (see appended table and ) CTI tests... : Material group IIIB; - 100<=CTI< Solid insulation Minimum distance through insulation (see appended table 1.5.1) Thin sheet material See appended table 5.2. Number of layers (pcs)... : 3 - Electric strength test... : See appended table Printed boards Insulation through PCB is made of 3 layers pre-preg material or minimum 0.4mm material. Distance through insulation Electric strength test for thin sheet insulating material... : See appended table Number of layers (pcs)... : 3 layers of prepreg material Wound components Insulation on winding wire of transformers T1 and T2 complies with Annex U. Number of layers (pcs)... : 3. See separate certificates of TIW used. Two wires in contact inside wound component; angle between 45 and : Not crossing at an angle between 45* and 90* Coated printed boards No special coating in order to reduce distances.

20 Issue Date: Page 18 of 63 Report Reference # E A82-UL General Sample preparation and preliminary inspection Thermal cycling Thermal ageing ( C)... : Electric strength test... : Abrasion resistance test Electric strength test... : Enclosed and sealed parts... : No enclosed or hermetically sealed components. Temperature T1=T2 = Tma - Tamb +10K ( C)... : Spacings filled by insulating compound... : For optocouplers, see appended table Electric strength test... : Component external terminations Coatings not used over terminations to increase effective creepage and clearance distances Insulation with varying dimensions No such transformer used.

21 Issue Date: Page 19 of 63 Report Reference # E A82-UL-1 3 WIRING, CONNECTIONS AND SUPPLY 3.1 General Current rating and overcurrent protection Internal wiring and interconnection cables in the distribution of primary circuit power are protected against overcurrent and short circuit by suitably rated protective device Protection against mechanical damage Wireways are smooth and free from edges. Wires are adequately fixed to prevent excessive strain on wire and terminals and avoiding damage to the insulation of the conductors Securing of internal wiring Internal wiring is secured against excessive strain, loosening of terminals and damage to the conductor insulation Insulation of conductors Insulation on internal conductors is considered to be of adequate quality and suitable for the application and the working voltage involved. (see also appended table 5.2) Beads and ceramic insulators No beads or similar ceramic insulators on conductors Screws for electrical contact pressure Electrical screw connection is only connecting protective bonding terminal to chassis. Metal screw engages more than 2 threads Insulating materials in electrical connections No contact pressure through insulating material Self-tapping and spaced thread screws Refer to clause Termination of conductors Terminations cannot become displaced so that clearances and creepage distances can be reduced. Spring washer is used. 10 N pull test Sleeving on wiring Sleeves can only be removed

22 Issue Date: Page 20 of 63 Report Reference # E A82-UL-1 by breaking or cutting. Some sleeves are heatshrinkable. 3.2 Connection to an a.c. mains supply or a d.c. mains supply Means of connection Equipment is for building-in. To be considered in the end Connection to an a.c. mains supply Connection to a d.c. mains supply Multiple supply connections Permanently connected equipment Number of conductors, diameter (mm) of cable and - conduits... : Appliance inlets Power supply cords AC power supply cords Power supply cord is not provided with the equipment. Must be considered in the endsystem Type... : - Rated current (A), cross-sectional area (mm²), - AWG... : DC power supply cords Cord anchorages and strain relief Mass of equipment (kg), pull (N)... : - Longitudinal displacement (mm)... : Protection against mechanical damage Cord guards D (mm); test mass (g)... : - Radius of curvature of cord (mm)... : Supply wiring space

23 Issue Date: Page 21 of 63 Report Reference # E A82-UL Wiring terminals for connection of external conductors Wiring terminals Connection of non-detachable power supply cords Screw terminals Conductor sizes to be connected Rated current (A), cord/cable type, cross-sectional - area (mm²)... : Wiring terminal sizes Rated current (A), type and nominal thread - diameter (mm)... : Wiring terminals design Grouping of wiring terminals Stranded wire 3.4 Disconnection from the mains supply General requirement Disconnect devices Equipment is for building-in. Must be checked in the end system Permanently connected equipment Not permanently connected equipment Parts which remain energized No parts remain energized after the disconnect device is operated Switches in flexible cords Single-phase equipment and d.c. equipment Three-phase equipment Switches as disconnect devices Plugs as disconnect devices Interconnected equipment Multiple power sources

24 Issue Date: Page 22 of 63 Report Reference # E A82-UL Interconnection of equipment General requirements SELV is only connected to SELV. There are no provisions for connection to TNV circuit in the equipment Types of interconnection circuits... : SELV circuits only ELV circuits as interconnection circuits 4 PHYSICAL REQUIREMENTS 4.1 Stability Angle of 10 Test: force (N)... :

25 Issue Date: Page 23 of 63 Report Reference # E A82-UL Mechanical strength General Complies with the requirement also after tests described below are applied Steady force test, 10 N No hazard, ref. comment in appended table , Steady force test, 30 N This is a component level power supply. Outer surfaces of the equipment are tested at 30N Steady force test, 250 N Test was performed on the fan grille. Equipment is for building-in. Compliance must also be checked in the endsystem Impact test Refer below: Fall test Swing test This is a component level power supply. Outer surfaces (fan grill) intended to form outer enclosure in end product tested Drop test Drop test not applicable Stress relief test Metal enclosure Cathode ray tubes CRT(s) not used in the equipment. Picture tube separately certified... : High pressure lamps No high pressure lamps in the equipment Wall or ceiling mounted equipment; force (N)... : Not intended to be mounted on a wall or ceiling.

26 Issue Date: Page 24 of 63 Report Reference # E A82-UL Design and construction Edges and corners All edges and corners are rounded and/or smoothed Handles and manual controls; force (N)... : Handles are reliably fixed in order to prevent loosening Adjustable controls No hazardous adjustable controls Securing of parts No loosening of parts impairing creepage distances or clearances is likely to occur Connection of plugs and sockets Direct plug-in equipment Not intended to plug directly into a wall socket-outlet. Dimensions (mm) of mains plug for direct plug-in. : Torque and pull test of mains plug for direct plug-in; torque (Nm); pull (N)... : Heating elements in earthed equipment No heating element in the equipment Batteries No batteries in the equipment Oil and grease Insulation is not exposed to oil, grease etc Dust, powders, liquids and gases The equipment does not generate ionizing radiation or use a laser, and does not contain flammable liquids or gases Containers for liquids or gases No containers for liquids or gases in the equipment Flammable liquids... : The equipment does not contain flammable liquid. Quantity of liquid (l)... : Flash point ( C)... : Radiation; type of radiation The equipment does not generate ionizing radiation General Ionizing radiation The equipment does not generate ionizing radiation. Measured radiation (pa/kg)... : -

27 Issue Date: Page 25 of 63 Report Reference # E A82-UL-1 Measured high-voltage (kv)... : - Measured focus voltage (kv)... : - CRT markings... : Effect of ultraviolet (UV) radiation on materials The equipment does not produce significant UV radiation. Part, property, retention after test, flammability classification... : Human exposure to ultraviolet (UV) radiation... : The equipment does not produce significant UV radiation Laser (including LEDs) Diffuesed Light Emitting Diodes are used as indicating lights only. Laser class... : Class I Other types... : The equipment does not generate other types of radiation. 4.4 Protection against hazardous moving parts General No hazardous moving parts are accessible to users Protection in operator access areas Fan blades are inacessible to operator Protection in restricted access locations Not intended for installation in RAL Protection in service access areas Unintentional contact is not likely in service access areas. 4.5 Thermal requirements Maximum temperatures See appended table 4.5 Normal load condition per Annex L... : See appended table Resistance to abnormal heat See appended table

28 Issue Date: Page 26 of 63 Report Reference # E A82-UL Openings in enclosures Top and side openings This is a component level power supply. Outer surfaces intended to form outer enclosure (front panel) have front openings (ventilation slots). Must be considered at end system. Dimensions (mm)... : Bottoms of fire enclosures No bottom openings. Construction of the bottom... : Doors or covers in fire enclosures Fire enclosure construction is considered to comply with the requirements. No doors or covers in the enclosure Openings in transportable equipment The unit is not regarded as transportable equipment Adhesives for constructional purposes No barrier secured by adhesive inside enclosure. Conditioning temperature ( C)/time (weeks)... : -

29 Issue Date: Page 27 of 63 Report Reference # E A82-UL Resistance to fire Reducing the risk of ignition and spread of flame Method 1 is used. Method 1, selection and application of components wiring and materials (see appended table 4.7) Method 2, application of all of simulated fault condition tests Conditions for a fire enclosure Refer below: Parts requiring a fire enclosure Unit has metal enclosure which is also considered as fire enclosure Parts not requiring a fire enclosure The fire enclosure is required to cover all parts Materials General Components and materials have adequate flammability classification. See appended table Materials for fire enclosures The fire enclosure is made of metal Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures Connectors are rated minimum V-2. Other materials inside fire enclosure are minimum V-2 material. Wires used are minimum VW- 1 material Materials for air filter assemblies No air filters in the equipment Materials used in high-voltage components No parts exceeding 4kV.

30 Issue Date: Page 28 of 63 Report Reference # E A82-UL-1 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 5.1 Touch current and protective conductor current General Equipment under test (EUT) Test conducted in accordance with to Test circuit TN power distribution system Application of measuring instrument Measuring instrument D1 is used Test procedure Considered Test measurements Refer below: Test voltage (V)... : AC 264 V - Measured touch current (ma)... : 0.55 (PE), (Output) - Max. allowed touch current (ma)... : 3.5 ma (PE), 0.25 (Output) - Measured protective conductor current (ma)... : - - Max. allowed protective conductor current (ma)... : Equipment with touch current exceeding 3.5 ma.. : The touch current does not exceed 3.5mA Touch currents to and from telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network and a cable distribution system Not connected to a telecommunication network. Not connected to a telecommunication network. Test voltage (V)... : - Measured touch current (ma)... : - Max. allowed touch current (ma)... : Summation of touch currents from telecommunication networks... : Not connected to a telecommunication network. 5.2 Electric strength General (see appended table 5.2) Test procedure (see appended table 5.2)

31 Issue Date: Page 29 of 63 Report Reference # E A82-UL Abnormal operating and fault conditions Protection against overload and abnormal operation (see appended table 5.3) Motors Fan has complied with Annex B Transformers See appended Annex C Functional insulation... : Functional insulation complies with alternative requirements c) Electromechanical components Abnormal test is performed on relay. See Appended table Simulation of faults See appended table Unattended equipment No thermostats, temperature limiters or thermal cut-outs Compliance criteria for abnormal operating and fault conditions No fire or molten metal occurred and no deformation of enclosure during the tests. No reduction of clearance and creepage distances. Electric strength test is made on basic, and reinforced insulation. 6 CONNECTION TO TELECOMMUNICATION NETWORKS 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment Protection from hazardous voltages Separation of the telecommunication network from earth Requirements Equipment is not intended to be connected to telecommunication networks. Test voltage (V)... : - Current in the test circuit (ma)... : Exclusions... :

32 Issue Date: Page 30 of 63 Report Reference # E A82-UL Protection of equipment users from overvoltages on telecommunication networks Separation requirements Electric strength test procedure Impulse test Steady-state test Compliance criteria 6.3 Protection of the telecommunication wiring system from overheating Max. output current (A)... : - Current limiting method... : - 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS 7.1 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment 7.2 Protection of equipment users from overvoltages on the cable distribution system 7.3 Insulation between primary circuits and cable distribution systems General Voltage surge test Impulse test

33 Issue Date: Page 31 of 63 Report Reference # E A82-UL-1 A Annex A, TESTS FOR RESISTANCE TO HEAT AND FIRE A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see ) A.1.1 Samples... : - Wall thickness (mm)... : - A.1.2 Conditioning of samples; temperature ( C)... : A.1.3 Mounting of samples... : A.1.4 Test flame A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : -

34 Issue Date: Page 32 of 63 Report Reference # E A82-UL-1 A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material... : - Wall thickness (mm)... : - A.2.2 Conditioning of samples A.2.3 Mounting of samples A.2.4 Test flame A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : - A.2.7 Alternative test acc. to IEC , cl. 4, 8 Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : - A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion

35 Issue Date: Page 33 of 63 Report Reference # E A82-UL-1 B Annex B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see and 5.3.2) B.1 General requirements Position... : Secondary - Manufacturer... : Sanyo Denki - Type... : 9G0612P1J051 - Rated values... : 12V 2.1A - B.2 Test conditions B.3 Maximum temperatures B.4 Running overload test B.5 Locked-rotor overload test Test duration (days)... : - Electric strength test: test voltage (V)... : - B.6 Running overload test for d.c. motors in secondary circuits B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 Test procedure B.7.2 Alternative test procedure; test time (h)... : Subject to 7 hour locked rotor bench test during component evaluation. B.7.3 Electric strength test B.8 Test for motors with capacitors B.9 Test for three-phase motors B.10 Test for series motors Operating voltage (V)... : -

36 Issue Date: Page 34 of 63 Report Reference # E A82-UL-1 C Annex C, TRANSFORMERS (see and 5.3.3) Position... : Between Primary and - Secondary Manufacturer... : ASTEC/EMERSON - Type... : - - Rated values... : Power transformer T105 and - Auxiliary transformer T103 is designated Class F Method of protection... : Method 1. - C.1 Overload test (see appended table 5.3) C.2 Insulation (see appended table 5.2) Protection from displacement of windings... : (see appended table 5.2) D Annex D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS D.1 Measuring instrument Measuring instrument used is as per IEC60990, Figure 4. D.2 Alternative measuring instrument Not used. E Annex E, TEMPERATURE RISE OF A WINDING F Annex F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10)

37 Issue Date: Page 35 of 63 Report Reference # E A82-UL-1 G Annex G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES G.1 Summary of the procedure for determining minimum clearances G.2 Determination of mains transient voltage (V) G.2.1 AC mains supply G.2.2 DC mains supply G.3 Determination of telecommunication network transient voltage (V) :... : Equipment is not intended to be connected to telecommunication networks. G.4 Determination of required withstand voltage (V)... : Considered G.5 Measurement of transient levels (V)... : G.6 Determination of minimum clearances... : (see appended table and ) H ANNEX H, IONIZING RADIATION (see ) J Annex J, TABLE OF ELECTROCHEMICAL POTENTIALS (see ) Metal used... : aluminium - K ANNEX K, THERMAL CONTROLS (see and 5.3.7) K.1 Making and breaking capacity K.2 Thermostat reliability; operating voltage (V)... : K.3 Thermostat endurance test; operating voltage (V) : K.4 Temperature limiter endurance; operating voltage (V)... : K.5 Thermal cut-out reliability K.6 Stability of operation

38 Issue Date: Page 36 of 63 Report Reference # E A82-UL-1 L Annex L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see and 4.5.1) L.1 Typewriters L.2 Adding machines and cash registers L.3 Erasers L.4 Pencil sharpeners L.5 Duplicators and copy machines L.6 Motor-operated files L.7 Other business equipment M Annex M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) M.1 Introduction M.2 Method A M.3 Method B M.3.1 Ringing signal M Frequency (Hz)... : - M Voltage (V)... : - M Cadence; time (s), voltage (V)... : - M Single fault current (ma)... : - M.3.2 Tripping device and monitoring voltage... : M Conditions for use of a tripping device or a monitoring voltage M Tripping device M Monitoring voltage (V)... : N Annex N, IMPULSE TEST GENERATORS (see , , and clause G.5) N.1 ITU-T impulse test generators N.2 IEC impulse test generator

39 Issue Date: Page 37 of 63 Report Reference # E A82-UL-1 P Annex P, NORMATIVE REFERENCES Q Annex Q, BIBLIOGRAPHY R Annex R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S Annex S, PROCEDURE FOR IMPULSE TESTING (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing T Annex T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2)... : - U Annex U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see )... : TIW used for transformer T1 and T2 is separately certified by VDE under Annex U. -

40 Issue Date: Page 38 of 63 Report Reference # E A82-UL TABLE: list of critical components Object/part No. Input Connector (CN1) Manufacturer/ trademark FCI USA Inc. type/model technical data Product Category CCN(s) Powerblade Series 5XXXX Rated 30A, 600Vac, 125degC. Secured to the Primary mainboard PWB by soldering, with its grounding conductor soldered directly into the Primary mainboard PWB. PWB screw trace adjacent to grounded terminal, provided with marking IEC Handle Various Various Steel, shaped as shown (minimum overall by 81.0 by 42.0mm, 1.5mm thick. Attached to Base by 2 rivets DS Base Various Various Steel, shaped as shown (minimum overall by by 77.0mm, 0.72 mm thick). Provided with 267 hexagonal slots on front panel each having opposite side measurements of 2.8mm. Cover Various Various Steel, L-shaped (minimum overall by by 66.8mm, 0.72mm thick). Provided with 15 ventilation slots, 8 of which measures 44.5 by 4.45mm and 7 of which measures 25.0 by 4.45mm. Secured to base with screws. ECBT Required Marks of Conformity UL (E66906) Supplement ID

41 Issue Date: Page 39 of 63 Report Reference # E A82-UL-1 Discharge Resistor (R2, R3, R36) Located before fuse Discharge Resistor (R2, R3, R36) Located before fuse (alternate) Discharge Resistor (R2, R3, R36) Located before fuse (alternate) Discharge Resistor (R2, R3, R36) Located before fuse (alternate) Y-Capacitors (C2, C3, C23) Y-Capacitors (C2, C3, C23) (alternate) Y-Capacitors (C2, C3, C23) (alternate) Y-Capacitors (C2, C3, C23) (alternate) Y-Capacitors (C2, C3, C23) (alternate) Royal Electronic Fty. Thailand Co. Ltd. 1206W4J Rated 56 k ohm, 1/4W - - Phycomp Taiwan Ltd. RC01 Rated 56 k ohm, 1/4W - - TA-I TechnologyCo. Ltd. RM12 Rated 56 k ohm, 1/4W - - Various Various Rated 56 k ohm, 1/4W - - Evox Rifa AB PME271 Rated Max. 1.5nF, Min. 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Walsin Technology Corp. AH Rated Max. 1.5nF, Min. 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Murata Mfg Co Ltd KH Rated Max. 1.5nF, Min. 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Murata Mfg Co Ltd. KX Rated Max. 1.5nF, Min. 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Murata Mfg Co Ltd. KY Rated Max. 1.5nF, Min. 250Vac, 105 degc. Marked with Y1 or Y2. Certified with FOKY2 FOWX2 FOWX2 FOWX2 FOWX2 UL (E100117) UL (E146544) UL (E37921) UL (E37921) UL (E37921)

42 Issue Date: Page 40 of 63 Report Reference # E A82-UL-1 IEC Y-Capacitors (C2, C3, C23) (alternate) TDK Corp CD Rated Max. 1.5nF, Min. 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Y-Capacitors (C2, C3, TDK Corp CS Rated Max. 1.5nF, Min. C23) (alternate) 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Y-Capacitors (C2, C3, TDK Corp CY Rated Max. 1.5nF, Min. C23) (alternate) 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Y-Capacitors (C2, C3, Various Various Rated Max. 1.5nF, Min. C23) (alternate) 250Vac, 105 degc. Marked with Y1 or Y2. Certified with IEC Y-Capacitors (C5, C6) Evox Rifa AB PME271 Rated Max. 2.2nF, Min. 250Vac, 125 degc. Marked with Y1 or Y2. Certified with IEC Y-Capacitors (C5, C6) (alternate) Y-Capacitors (C5, C6) (alternate) Y-Capacitors (C5, C6) (alternate) Walsin Technology Corp. AH Rated Max. 2.2nF, Min. 250Vac, 125 degc. Marked with Y1 or Y2. Certified with IEC Murata Mfg Co Ltd KH Rated Max. 2.2nF, Min. 250Vac, 125 degc. Marked with Y1 or Y2. Certified with IEC Murata Mfg Co Ltd. KX Rated Max. 2.2nF, Min. 250Vac, 125 degc. Marked with Y1 or Y2. Certified with IEC FOWX2 FOWX2 FOWX2 FOWX2 UL FOKY2 FOWX2 FOWX2 FOWX2 UL (E37861) UL (E37861) UL (E37861) UL (E100117) UL (E146544) UL (E37921) UL (E37921) Y-Capacitors (C5, C6) Murata Mfg Co Ltd. KY Rated Max. 2.2nF, Min. FOWX2 UL (E37921)

43 Issue Date: Page 41 of 63 Report Reference # E A82-UL-1 (alternate) Y-Capacitors (C5, C6) (alternate) Y-Capacitors (C5, C6) (alternate) Y-Capacitors (C5, C6) (alternate) Y-Capacitors (C5, C6) (alternate) Fuse (F1) 250Vac, 125 degc. Marked with Y1 or Y2. Certified with IEC TDK Corp CD Rated Max. 2.2nF, Min. FOWX2 250Vac, 125 degc. Marked UL (E37861) with Y1 or Y2. Certified with IEC TDK Corp CS Rated Max. 2.2nF, Min. FOWX2 250Vac, 125 degc. Marked UL (E37861) with Y1 or Y2. Certified with IEC TDK Corp CY Rated Max. 2.2nF, Min. FOWX2 250Vac, 125 degc. Marked UL (E37861) with Y1 or Y2. Certified with IEC Various Various Rated Max. 2.2nF, Min. FOWX2 UL 250Vac, 125 degc. Marked with Y1 or Y2. Certified with IEC Cooper Industries GBB-V Rated. F25A 250Vac. JFHR2 Inc, Bussmann Div UL (E56412) Fuse (F1) (alternate) Littelfuse Inc 324 Rated. F25A 250Vac. JDYX2 UL (E10480) X-Capacitors (C4, C7, Vishay BC FOWX2 UL C29) Components BV (E112471) X-Capacitors (C4, C7, C29) (alternate) X-Capacitors (C4, C7, C29) (alternate) 339 Rated Max. 1.0*F, Min. 250Vac,125 degc. Marked with X1 or X2. Certified with IEC Evox Rifa AB PHE840M Rated Max. 1.0*F, Min. 250Vac,125 degc. Marked with X1 or X2. Certified with IEC Iskra Kondenzatorji D D KNB1560 Rated Max. 1.0*F, Min. 250Vac,125 degc. Marked with X1 or X2. Certified with IEC FOKY2 FOKY2 UL (E100117) UL (E103619)

44 Issue Date: Page 42 of 63 Report Reference # E A82-UL-1 X-Capacitors (C4, C7, C29) (alternate) X-Capacitors (C4, C7, C29) (alternate) Varistor (VDR1) Varistor (VDR1) (alternate) Varistor (VDR1) (alternate) Common Mode Choke (L3) Common Mode Choke (L4) Bridge Rectifier (D1) (alternate) Hua Jung Components Co Ltd MKP Rated Max. 1.0*F, Min. 250Vac,125 degc. Marked with X1 or X2. Certified with IEC Various Various Rated Max. 1.0*F, Min. 250Vac,125 degc. Marked with X1 or X2. Certified with IEC FOKY2 FOKY2 UL UL (E149075) Thinking Electronic Industrial Co Ltd TVR14511 Rated 320Vac XUHT2 UL (E172642) Uppermost Electronic V14K320 Rated 320Vac XUHT2 UL IndustriesCo Ltd (E105157) Various Various Rated min 275Vac - UL Astec International Limited / Emerson Network Power Astec International Limited/ Emerson Network Power Vishay Hongkong Ltd. Gulf Semiconductor Ltd Rated 130 *C. Construction with magnetic wire (OBMW2), rated min. 130 *C Rated 130 *C. Construction with magnetic wire (OBMW2), rated min. 130 *C GBPC-W Min. 25A Min. 600V GBPCW Min. 25A Min. 600V (alternate) Various Various Min. 25A Min. 600V PFC Choke (L1) Astec International Limited/ Emerson Network Power PFC Choke (L2) PFC Transistors(Q6, Q7, Q8, Q9) Astec International Limited/ Emerson Network Power Infineon Technologies AG Rated 130 *C. Construction with magnetic wire (OBMW2), rated min. 130 *C Rated 130 *C. Construction with magnetic wire (OBMW2), rated min. 130 *C IPP60R199CP Rated min. 16A, min. 600V. - -

45 Issue Date: Page 43 of 63 Report Reference # E A82-UL-1 PFC Transistors(Q6, Q7, Various Various Rated min. 16A, min. 600V. - - Q8, Q9) (alternate) Bulk Capacitors (C20, Nichicon GG Rated min. 1000*F, min. 400V, - - C21) 105degC. Bulk Capacitors (C20, C21) (alternate) Various Various Rated min. 1000*F, min. 400V, 105degC. - - Relay (RLY1) Tyco Electronics OJE-SS-112HM2 Rated. 10A, 250Vac, 85 degc. NRNT2 (Shenzhen) Co Ltd. UL (E82292) Relay (RLY1) (alternate) Tyco Electronics OJ-SS-112LMHF Rated. 8A, 250Vac, 105 degc. NRNT2 (Shenzhen) Co Ltd. UL (E82292) Relay (RLY1) (alternate) Song Chuan 835 Rated. 8A, 277Vac, 85 degc. NRNT2 Precision Co Ltd UL (E74321) Relay (RLY1) (alternate) Ningbo Forward Relay Corp. Ltd JZC-32F Rated. 5A, 250Vac, 105 degc. NLDX2 UL (E160644) Relay (RLY1) (alternate) Various Various Rated. Min V-2, 85 degc. NRNT2 or NLDX2 UL Buck Choke (L101) Astec International Limited / Emerson Network Power Rated 130 degc. Construction with magnetic wire (OBMW2), rated min. 130 degc - - Buck Transistors (Q125, Infineon IPP60R199CP Rated min. 16A, Min. 600V - - Q140, Q145) Technologies AG Buck Transistors (Q125, Various Various Rated min. 16A, Min. 600V - - Q140, Q145) (alternate) Current Transformer (T101, T102) Gate Drive Transformers (T114, T115) Astec International Limited / Emerson Network Power Astec International Limited / Emerson Network Power Class A Insulation system. Construction with magnetic wire (OBMW2), rated min. 130 degc X Rated. 130*C - - (windings are etched on PCB); where X is any numeric number from 0-9 for revision no. that does not affect

46 Issue Date: Page 44 of 63 Report Reference # E A82-UL-1 Power Transformer (T105) Switching Transistors (Q169, Q170, Q171, Q172, Q175, Q176, Q177, Q178) Switching Transistors (Q169, Q170, Q171, Q172, Q175, Q176, Q177, Q178) (alternate) Auxiliary Transformer (T103) Switching Transistor (Q100) Switching Transistor (Q100) (alternate) Switching Transistor (Q100) (alternate) Switching Transistor (Q100) (alternate) Switching Transistor (Q100) (alternate) Optocouplers (IC1, IC2, IC105, IC106, IC101, IC102) Optocouplers (IC1, IC2, IC105, IC106, IC101, IC102) (alternate) Optocouplers (IC1, IC2, IC105, IC106, IC101, IC102) (alternate) Astec International Limited / Emerson Network Power Infineon Technologies AG safety Provided with Class F OBJY2 insulation system, designate UL (E94225) B IPP60R125CP Min. 25A Min. 900V - - Various Various Min. 25A Min. 600V - - Astec International Limited / Emerson Network Power Provided with Class F insulation system, designate A OBJY2 Fairchild FQP4N90C Min. 3A Min. 900V - - International Rectifier IRFBF30PBF Min. 3A Min. 900V - - S.E. STMicroElectronics STP3NK90Z Min. 3A Min. 900V - - Renesas Technology 2SK1807-E Min. 3A Min. 900V - - Various Various Min. 25A Min. 600V - - Vishay Infrared Components Inc Fairchild Semiconductor Corp Toshiba Corp, Semiconductor Co Discrete SFH690A/B/ (System U) HMA121 TLP181 Rated Isolation voltage 3125Vac, 110 degc Rated Isolation voltage 3750Vac, 110 degc Rated Isolation voltage 3750Vac, 110 degc FPQU2 FPQU2 FPQU2 UL (E94225) UL (E52744) UL (E90700) UL (E67349)

47 Issue Date: Page 45 of 63 Report Reference # E A82-UL-1 Optocouplers (IC1, IC2, IC105, IC106, IC101, IC102) (alternate) Semiconductor Div Vishay Infrared Components Inc SFH (System H or J) Rated Isolation voltage 4420Vac, 110 degc Base insulator Toray Industries Inc. Lumirror S10 Rated VTM-2, 105 degc. Minimum Overall dimension of by mm, 0.125mm thick. Serves to insulate primary pins and traces on SEC Main PWB and chassis/pe. Secured in position to base via mounting holes provided. Cover Insulator Toray Industries Inc. Lumirror S10 Rated VTM-2, 105 degc. Minimum Overall dimension of by mm, 0.125mm thick. Serves to insulate primary pins and traces on PRI Main PWB and chassis/pe. Secured in position to base via mounting holes provided. D1 Heatsink Insulator Toray Industries Inc. Lumirror S10 Rated VTM-2, 105 degc. Minimum Overall dimension of 33.0 by 15.0mm, 0.125mm thick. Serves to insulate primary components D1 heatsink / C9 and chassis/pe. Secured in C9 pins and by safety approved adhesive. T103 Insulator Toray Industries Inc. Lumirror S10 Rated VTM-2, 105 degc. Minimum Overall dimension of FPQU2 QMFZ2 QMFZ2 QMFZ2 QMFZ2 UL (E52744) UL (E86511) UL (E86511) UL (E86511) UL (E86511)

48 Issue Date: Page 46 of 63 Report Reference # E A82-UL-1 T105 Insulator Sabic Innovative US L L C Plastic Valox FR by 13.0mm, 0.125mm thick. Serves to insulate T103 primary windings and secondary heatsink. Secured in T103 pins and by safety approved adhesive. Rated VTM-2, 105 degc. Overall dimension of 75.5 by 43.0 mm, 0.40mm thick. Serves to insulate primary components and T105 secondary parts. Secured in position to base via safety approved adhesive. Fan insulator Toray Industries Lumirror S10 Rated VTM-2, 105 degc. Diameter dimension of 35.0mm, mm thick. Serves to insulate primary components on PRI Main PWB and Secondary fan motor. Secured in position via safety approved adhesive and contact pressure. QMFZ2 QMFZ2 UL (E255088) UL (E86511) CN4, CN103 connector Land Win Electronic 4201P Rated. 6A per pin, 250Vac, 105 ECBT2 UL Corp degc. (E159426) CN4, CN103 mating Land Win Electronic 4200F Rated. 6A per pin, 250Vac, 105 ECBT2 UL connector Corp degc. (E159426) Fan Sanyo Denki Co Ltd. 9G0612P1J051 Rated 12 Vdc, 2.1 A GPWV2 UL (E46810) PWB Various Various Rated V-0, 130*C. PRI Main PWB Overall measured 182 mm by 95 mm 1.5 mm thick. Secondary PWB, overall measured 195mm, 100mm, 1.5 mm thick. QMFZ2 UL Heatsink for for D1 Various Various Aluminum. Overall measured - -

49 Issue Date: Page 47 of 63 Report Reference # E A82-UL-1 Heatsink (HTSK103) for Q140, Q145, Q125, D141 and Q100 Heatsink (HTSK101) for Q171, Q172, Q177 and D178 Heatsink (HTSK104) for Q169, Q170, Q175 and D176 Heatsink (HTSK104) for 45mm by 36mm by 9.8 mm height. Various Various Aluminum. Overall measured 74.9mm by 12.8mm, 28mm height. Various Various Aluminum. Overall measured 60mm by 24mm, 2mm thick. Various Various Aluminum. Overall measured 60mm by 24mm, 2mm thick. Various Various Aluminum. Overall measured Q105, D105 and D130 29mm by 24mm, 2mm thick. DS Base - - Steel, shaped as shown (minimum overall by by 77.0mm, 0.72 mm thick). Provided with fan guard at the front panel, overall measuring approximately 53 by 53mm with three concentric rings, each measuring min 1.1mm thick spaced from each other by min 3.6mm. Secured to cover chassis by screws. Output Connector Various Various Constructed with (QMFZ2), rated min. V-2 Label Artwork Various Various Suitable for use on each type of surface to which applied, rated for maximum surface temperature specified PGDQ2, PGJI2 UL

50 Issue Date: Page 48 of 63 Report Reference # E A82-UL TABLE: electrical data (in normal conditions) fuse # I rated (A) U (V) P (W) I (ma) I fuse (ma) condition/status F AC LOAD:=12V, ; 3.3Vsb, 3A F AC LOAD:=12V, ; 3.3Vsb, 3A F AC LOAD:=12V, ; 3.3Vsb, 3A F AC LOAD:=12V, ; 3.3Vsb, 3A F AC LOAD:=12V, ; 3.3Vsb, 3A F AC LOAD:=12V, ; 3.3Vsb, 3A F AC LOAD:=12V, ; 3.3Vsb, 3A F AC LOAD:=12V, ; 3.3Vsb, 3A supplementary information: Also covers DS (input current rating is 16.0 A). Tests at 180VAC and 264 VAC input for reference only and clearance cl and creepage distance dcr at/of: TABLE: clearance and creepage distance measurements Up (V) U r.m.s. (V) required cl (mm) cl (mm) required dcr (mm) Functional:*Measured between Live and Neutral traces(pri Main PWB) Basic*(Primary PE):*Measured between Live trace and PE trace (PRI Main PWB) Basic*(Primary PE):*Measured between Neutral trace and PE trace (PRI Main PWB) Basic (Primary PE):*Measured between CN4 pin trace and PE (PRI Main PWB) Basic (Primary PE):*Measured between CN103 pin trace and PE (SEC Main PWB) Reinforced (Prim Sec.):*Measured between IC106 optocoupler primary and secondary pins (PRI CTRL PWB) Reinforced (Prim.-Sec.): *Measured between Primary dcr (mm)

51 Issue Date: Page 49 of 63 Report Reference # E A82-UL-1 and Secondary trace (Gate Drive PWB) Reinforced (Prim.- Sec.):*Measured between T101/T102 Primary and Secondary pin trace (PRI Main PWB) Reinforced (Prim.- Sec.):*Measured between T105 Primary pin trace to Secondary windings (PRI Main PWB) Reinforced (Prim.- Sec.):*Measured between T103 Primary and Secondary pin trace (PRI Main PWB) Reinforced (Prim.- Sec.):*Measured between T103 1S Primary pin trace and T115 Secondary pin trace (PRI Main PWB) Reinforced (Prim.- Sec.):*Measured between CN103 Primary pin trace and CN104 Secondary pin trace (PRI Main PWB) supplementary information: TABLE: distance through insulation measurements distance through insulation di at/of: Up (V) test voltage (V) required di (mm) T105 PBT Insulator 340 AC Base Insulator 340 AC supplementary information: - di (mm) 4.5 TABLE: temperature rise measurements test voltage (V)... AC18 0 AC264 AC t1 ( C)

52 Issue Date: Page 50 of 63 Report Reference # E A82-UL-1 t2 ( C) maximum temperature T of part/at: T ( C) allowed Tmax ( C) Ambient CN C C F L C C C L D L L RLY C C C CN IC IC T103 COIL (CLASS F) T103 CORE HTSK IC IC L T105 COIL (SYNC RECT 1) (CLASS F) T105 CORE (SYNC RECT 1) T105 COIL (SYNC RECT 2) (CLASS F) T105 CORE (SYNC RECT 2) T T HANDLE FAN GRILL BOTTOM ENCLOSURE (105) BOTTOM ENCLOSURE (D1) SK106 (OUTPUT CONNECTOR) Q C C C D1 HTSK CN

53 Issue Date: Page 51 of 63 Report Reference # E A82-UL-1 T T temperature T of winding: R 1 (Ω) R 2 ( Ω) T ( C) allowed Tmax ( C) supplementary information: Test Condition 1 and 2 are for DS Test condition 3 is for DS having reverse airflow conditions. insulation class TABLE: ball pressure test of thermoplastics allowed impression diameter (mm)... : 2.0 part test temperature ( C) impression diameter (mm) T103 bobbin (EI Dupont Rynite FR530) T101 bobbin (EI Dupont Rynite FR50) CN4/CN103 (landwin 4201P) CN supplementary information: TABLE: resistance to fire part manufacturer of material type of material thickness(mm) flammability class supplementary information: See appended tabe TABLE: electric strength tests, impulse tests and voltage surge tests test voltage applied between: test voltage (V) a.c./d.c. breakdown Yes / No Power Supply: - - Primary to Secondary AC 3000 No (passed) Primary to Enclosure (P.E.) AC 1979 No (passed) Power Transformer T105: - - Primary to Secondary AC 3000 No (passed) Primary to Core AC 3000 No (passed) Secondary to Core AC 500 No (passed) Auxiliary Transformer T103: - -

54 Issue Date: Page 52 of 63 Report Reference # E A82-UL-1 Primary to Secondary AC 3000 No (passed) Primary to Core AC 1979 No (passed) Secondary to Core AC 1979 No (passed) Gate Drive Transformers T101/T102: - - Primary to Secondary AC 3000 No (passed) Primary to Core AC 3000 No (passed) Current Transformers T114/T115: - - Primary to Secondary AC 3000 No (passed) Insulators: - - Basic - - Type Lumirror S10 (0.125mm thick) AC 1979 No (passed) Reinforced - - Type Valox FR1 (0.40mm thick) AC 3000 No (passed) supplementary information: TABLE: fault condition tests ambient temperature ( C)... : 24.7 model/type of power supply... : DS manufacturer of power supply... : ASTEC/EMERSON rated markings of power supply... : DS : Input : Vac; 50/60Hz 20.0A Output : +12V, 240A; 3.3Vsb, 3A component No. +3.3Vsb output +12V output fault test voltage (V) test time fuse No. DS2900-3: Input : Vac; 50/60Hz 20.0A Output : +12V, 240A; 3.3Vsb, 3A fuse current (A) result s-c AC mins. F Upon shorting, all outputs shutdown immediately. T101: 38.8*C T102: 41.8*C T103: 43.3*C T105: 72.4*C T114: 49.2*C T115: 39.6*C s-c AC mins. F Upon shorting, +12V output shutdown immediately while

55 Issue Date: Page 53 of 63 Report Reference # E A82-UL Vsb output +12V output IC1 (Pin 1-2) IC1 (Pin 3-4) +3.3Vsb output remained normal. T101: 38.4*C T102: 41.0*C T103: 46.4*C T105: 71.3*C T114: 48.4*C T115: 39.1*C o-l AC240 4 hrs. F No visible effect until thermal equilibrium. Overload was conducted at 3.80A (max output power 11.59VA). Beyond 3.80A load, output shutdown immediately. T101: 27.8*C T102: 28.6*C T103: 43.3*C T105: 41.6*C T114: 42.5*C T115: 35.4*C o-l AC240 4 hrs. F No visible effect until thermal equilibrium. Overload was conducted at 269.5A (max output power VA). Beyond 269.5A load, output shutdown immediately. T101: 40.8*C T102: 43.9*C T103: 38.9*C T105: 85.2*C T114: 53.0*C T115: 40.9*C s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 34.0*C T102: 39.9*C T103: 40.2*C T105: 86.0*C T114: 60.3*C T115: 43.9*C s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 32.7*C T102: 36.9*C T103: 38.9*C T105: 85.7*C T114: 58.6*C

56 Issue Date: Page 54 of 63 Report Reference # E A82-UL-1 IC2 (Pin 1-2) IC2 (Pin 3-4) IC101*C (Pin 1-2) IC101 (Pin 3-4) IC101 (Pin 3-4) IC102 (Pin 1-2) T115: 42.9*C s-c AC240 1 hr. F All outputs shutdown immediately. T101: 33.0*C T102: 41.9*C T103: 41.7*C T105: 83.5*C T114: 55.7*C T115: 42.5*C s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 32.4*C T102: 37.1*C T103: 39.0*C T105: 85.3*C T114: 57.7*C T115: 42.9*C s-c AC240 1 hr. F After 1 minute, +12V output shutdown while +3.3Vsb output still normal. T101: 33.0*C T102: 40.7*C T103: 44.6*C T105: 82.3*C T114: 59.1*C T115: 44.8*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output still normal. T101: 31.8*C T102: 40.1*C T103: 43.8*C T105: 82.5*C T114: 55.4*C T115: 42.0*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output still normal. T101: 31.8*C T102: 40.1*C T103: 43.8*C T105: 82.5*C T114: 55.4*C T115: 42.0*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output still normal. T101: 32.6*C

57 Issue Date: Page 55 of 63 Report Reference # E A82-UL-1 IC102 (Pin 3-4) IC105 (Pin 1-2) IC105 (Pin 3-4) IC106 (Pin 1-2) IC106 (Pin 3-4) T102: 40.7*C T103: 44.6*C T105: 82.3*C T114: 55.7*C T115: 42.4*C s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 32.0*C T102: 37.2*C T103: 38.7*C T105: 84.7*C T114: 57.8*C T115: 42.3*C s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 33.5*C T102: 38.3*C T103: 39.8*C T105: 85.1*C T114: 58.5*C T115: 43.5*C s-c AC mins. F All outputs shutdown immediately. T101: 48.5*C T102: 54.3*C T103: 44.1*C T105: 81.2*C T114: 56.8*C T115: 47.3*C s-c AC mins. F No visible effect. Tested until thermal equilibrium. T101: 32.6*C T102: 37.5*C T103: 44.3*C T105: 82.2*C T114: 56.5*C T115: 42.7*C s-c AC mins. F All outputs shutdown immediately. T101: 48.3*C T102: 54.2*C T103: 44.0*C T105: 81.4*C T114: 56.9*C T115: 47.6*C Q8 (G-S) s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 31.8*C

58 Issue Date: Page 56 of 63 Report Reference # E A82-UL-1 T102: 37.2*C T103: 39.3*C T105: 84.4*C T114: 58.0*C T115: 42.3*C Q8 (G-D) s-c AC240 1 hr. F1 >57.5 F1 opened. Damaged: Q8 T101: 65.1*C T102: 68.8*C T103: 45.0*C T105: 88.5*C T114: 56.7*C T115: 47.2*C Q8 (D-S) s-c AC240 1 hr. F1 >57.5 F1 opened. Damaged: Q8 T101: 63.4*C T102: 65.2*C T103: 45.5*C T105: 88.6*C T114: 57.1*C T115: 47.9*C Q176 (G-S) s-c AC mins F V output shutdown immediately while +3.3Vsb output still normal. T101: 32.8*C T102: 39.9*C T103: 42.9*C T105: 82.2*C T114: 54.2*C T115: 41.7*C Q176 (G-D) s-c AC mins F V output shutdown immediately while +3.3Vsb output still normal. T101: 33.0*C T102: 40.1*C T103: 42.9*C T105: 82.3*C T114: 54.1*C T115: 42.0*C Q176 (D-S) s-c AC mins F V output shutdown immediately while +3.3Vsb output still normal. T101: 33.1*C T102: 40.0*C T103: 43.1*C T105: 82.5*C T114: 54.3*C T115: 42.1*C Q169 (G-S) s-c AC mins F V output shutdown immediately while +3.3Vsb

59 Issue Date: Page 57 of 63 Report Reference # E A82-UL-1 output still normal. T101: 35.3*C T102: 41.9*C T103: 45.3*C T105: 83.4*C T114: 56.9*C T115: 42.8*C Q169 (G-D) s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output still normal. T101: 35.2*C T102: 41.5*C T103: 45.1*C T105: 82.6*C T114: 57.0*C T115: 42.9*C Q169 (D-S) s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output still normal. T101: 35.4*C T102: 41.6*C T103: 45.3*C T105: 84.2*C T114: 56.8*C T115: 43.0*C Q140 (G-S) s-c AC mins. F No visible effect. Tested until thermal equilibrium. T101: 33.2*C T102: 36.9*C T103: 40.5*C T105: 82.9*C T114: 56.0*C T115: 43.1*C Q140 (G-D) s-c AC mins. F V output shutdown immediately while +3.3Vsb output still normal. T101: 34.3*C T102: 40.5*C T103: 44.6*C T105: 82.4*C T114: 55.1*C T115: 42.0*C Q140 (D-S) s-c AC mins. F V output shutdown immediately while +3.3Vsb output still normal. T101: 34.2*C T102: 40.6*C T103: 44.7*C

60 Issue Date: Page 58 of 63 Report Reference # E A82-UL-1 T105: 82.5*C T114: 54.9*C T115: 41.8*C Q100 (G-S) s-c AC mins. F All outputs shutdown immediately. T101: 51.2*C T102: 56.0*C T103: 48.3*C T105: 81.9*C T114: 59.8*C T115: 51.8*C Q100 (G-D) s-c AC mins. F All outputs shutdown immediately. Damaged: Q100, F103, IC104, IC1, IC2. T101: 53.1*C T102: 57.2*C T103: 49.0*C T105: 83.7*C T114: 63.2*C T115: 53.4*C Q100 (D-S) s-c AC mins. F All outputs shutdown immediately. Damaged: Q100, F103, IC104, IC1, IC2. T101: 53.6*C T102: 58.1*C T103: 49.2*C T105: 84.4*C T114: 65.1*C T115: 54.2*C T101 (1S- 1F) s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 37.0*C T102: 51.9*C T103: 43.0*C T105: 99.0*C T114: 59.5*C T115: 40.5*C T102 (1S- 1F) s-c AC240 1 hr. F No visible effect. Tested until thermal equilibrium. T101: 37.9*C T102: 52.2*C T103: 43.1*C T105: 99.8*C T114: 59.6*C T115: 40.7*C RLY1 (Pin o-c AC240 1 hr. F No visible effect. Tested

61 Issue Date: Page 59 of 63 Report Reference # E A82-UL-1 1) until thermal equilibrium. T101: 37.3*C T102: 50.8*C T103: 42.8*C T105: 95.9*C T114: 59.5*C T115: 40.9*C T103 (1S- 1F) T103 (2S- 2F) T103 (5S- 5F) T103 (4S- 4F) T103 (3S- 3F) s-c AC240 1 hr. F All outputs shutdown immediately. T101: 56.2*C T102: 56.2*C T103: 47.9*C T105: 82.0*C T114: 59.6*C T115: 51.7*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is cycling ( A / V). T101: 52.4*C T102: 58.5*C T103:125.6*C T105: 86.2*C T114: 59.4*C T115: 71.8*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is cycling ( A / V). T101: 52.5*C T102: 58.6*C T103:127.0*C T105: 86.9*C T114: 59.4*C T115: 71.9*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is cycling ( A / V). *C T101: 32.3*C T102: 39.8 T103: 66.4*C T105: 85.3*C T114: 54.1*C T115: 41.9*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is cycling (0.02-

62 Issue Date: Page 60 of 63 Report Reference # E A82-UL-1 T115 (3S- 3F) T115 (5S- 5F) T115 (6S- 6F) T115 (2S- 2F) T115 (7S- 7F) 0.57A / V). *C T101: 32.7*C T102: 40.0*C T103: 44.6*C T105: 78.8*C T114: 51.0*C T115: 39.9*C s-c AC mins. F After 10 secs., +12V output shutdown while +3.3Vsb output is still normal. *C T101: 34.9*C T102: 52.1*C T103: 47.0*C T105: 84.4*C T114: 58.9*C T115: 68.3*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is still normal. *C T101: 34.8*C T102: 51.5*C T103: 46.9*C T105: 85.2*C T114: 57.9*C T115: 67.3*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is still normal. *C T101: 35.1*C T102: 52.3*C T103: 47.2*C T105: 85.3*C T114: 58.2*C T115: 67.6*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is still normal. *C T101: 34.7*C T102: 51.3*C T103: 46.7*C T105: 84.4*C T114: 58.8*C T115: 67.5*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is still normal. *C T101: 34.7*C T102: 51.4*C

63 Issue Date: Page 61 of 63 Report Reference # E A82-UL-1 T105 (1F/4F - 1S/4S) T105 (3A - Com) T105 (2B - Com) T105 (2A - Com) T105 (3B - Com) T103: 46.5*C T105: 84.7*C T114: 58.7*C T115: 66.9*C s-c AC240 1 hr. F V output shutdown immediately while +3.3Vsb output is still normal. *C T101: 34.7*C T102: 51.7*C T103: 46.8*C T105: 84.9*C T114: 58.6*C T115: 67.1*C s-c AC mins. F No visible effect. Tested until thermal equilibrium. T101: 38.8*C T102: 50.6*C T103: 41.4*C T105:102.2*C T114: 57.2*C T115: 65.8*C s-c AC mins. F No visible effect. Tested until thermal equilibrium. T101: 40.6*C T102: 50.1*C T103: 40.8*C T105: 82.4*C T114: 56.3*C T115: 65.1*C s-c AC mins. F No visible effect. Tested until thermal equilibrium. T101: 38.9*C T102: 50.5*C T103: 41.8*C T105:106.2*C T114: 57.4*C T115: 66.1*C s-c AC mins. F No visible effect. Tested until thermal equilibrium. T101: 35.1*C T102: 50.2*C T103: 40.6*C T105: 82.1*C T114: 56.4*C T115: 64.9*C C21 s-c AC mins. F1 >57.5 F1 opened. T101: 53.7*C T102: 59.8*C T103: 47.2*C

64 Issue Date: Page 62 of 63 Report Reference # E A82-UL-1 T105: 86.0*C T114: 60.1*C T115: 51.9*C D6 s-c AC mins. F1 >57.5 F1 opened. Damaged: Q8 T101: 53.6*C T102: 59.6*C T103: 47.0*C T105: 85.8*C *T114: 60.1*C T115: 51.8*C D1 (+ - ~) s-c AC mins. F1 >57.5 F1 opened. Damaged: D1 T101: 51.7*C T102: 55.9*C T103: 47.2*C T105: 83.4*C T114: 59.7*C T115: 51.8*C D1 (- - ~) s-c AC mins. F1 >57.5 F1 opened. Damaged: D1 T101: 51.8*C T102: 56.2*C T103: 47.6*C T105: 84.2*C T114: 59.8*C T115: 52.1*C Front Panel b-v AC mins. F1 -- After 4mins., +12V output shutdown immediately while +3.3Vsb output remained normal. T101: 87.4*C T102: 92.1*C T103: 98.8*C T105:122.5*C T114: 77.9*C T115: 79.1*C Fan disconnect AC240 3 hrs. F v output cycling from V / A while +3.3Vsb output remained normal. T101: 84.7*C T102: 79.3 T103:113.2*C T105: 90.0*C T114: 90.8*C T115:108.6*C T103 (4S - Com) o-l AC240 4 hrs. F1 -- No visible effect until thermal equilibrium. Overload was conducted at 6.0A (max output power). Beyond 6.0A load, all

65 Issue Date: Page 63 of 63 Report Reference # E A82-UL-1 T105 (3A - Com) outputs shutdown immediately T101: 28.3*C T102: 29.2*C T103: 46.7*C T105: 42.5*C T114: 48.9*C T115: 39.8*C o-l AC hrs. F1 -- No visible effect until thermal equilibrium. Overload was conducted at 274.5A (max output power). Beyond 274.5A load, all outputs shutdown immediately. T101: 35.5*C T102: 41.1*C T103: 37.8*C T105: 99.2*C T114: 66.2*C T115: 45.5*C supplementary information: Results Key: IP = Internal protection operated (component indicated) CT = Constant temperatures were obtained TW = Transformer winding opened CD = Components damaged (damaged components indicated) NB = No indication of dielectric breakdown YB = Dielectric breakdown (time and location indicated) NC = Cheesecloth remained intact YC = Cheesecloth charred or flamed NT = Tissue paper remained intact YT = Tissue paper charred or flamed

66 Issue Date: Page 1 of 10 Report Reference # E A82-UL-1 Enclosure National Differences USA / Canada

67 Issue Date: Page 2 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict USA / Canada - Differences to :2001, First Edition 1.1 Equipment able to be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1, and when applicable, the National Electrical Safety Code, IEEE C Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded Special requirements apply to equipment intended for use outdoors For Pluggable Equipment Type A, the protection in the installation is assumed to be 20 A All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of CSA and UL component standards in Annex P All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like For other than limited power and TNV circuits, the type of output circuit identified for output connector External cable assemblies that exceed 3.05 m in length to be types specified in the NEC and CEC Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope Telephone line and extension cords and the like comply with UL 1863 and CSA C22.2 No Equipment intended for connection to a d.c. power (mains) distribution system is subject to special

68 Issue Date: Page 3 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict circuit classification requirements (e.g., TNV-2) Earthing of d.c. powered equipment provided. 1.7 Lamp replacement information indicated on lampholder in operator access area Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor Equipment voltage rating not higher than rating of the plug except under special conditions Special fuse replacement marking for operator accessible fuses Identification of terminal connection of the equipment earthing conductor Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used Marking located adjacent to terminals and visible during wiring Screw shell of Edison-base lampholder tied to the neutral conductor Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M b For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 ma peak or 30 ma d.c. under normal conditions b Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and routine testing.

69 Issue Date: Page 4 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict In the event of a single fault, the limits of apply to SELV circuits and accessible conductive parts. 2.5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with devices of higher ratings if operator replaceable. 2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth For Pluggable Equipment Type A, if neither a) or b) are applicable, the current rating of the circuit is taken as 20 A Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit Protective bonding conductors and their terminals of non-standard constructions (e.g. PWB traces) evaluated to limited short-circuit test of CSA C22.2 No.0.4. ed Limited Short Circuit. Tested at 3500A Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US and Canada Data for selection of special external branch circuit overcurrent devices marked on the equipment Standard supply outlets protected by overcurrent device in accordance with the NEC, and CEC, Part Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring Additional requirements for overcurrent protection apply to equipment provided with panelboards Non-motor-operated equipment requiring special overcurrent protective device marked with device rating Multi-layer winding wire subject to UL component wire requirements in addition to and Annex U Permissible combinations of internal wiring/external

70 Issue Date: Page 5 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict cable sizes for overcurrent and short circuit protection All interconnecting cables protected against overcurrent and short circuit. 3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC and CEC, Part 1. Equipment is for building-in. To be considered in the end system Permitted use for flexible cords and plugs Flexible cords provided with attachment plug rated 125% of equipment current rating Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord) Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC,

71 Issue Date: Page 6 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict Part Permanently connected equipment may have terminals or leads not smaller than No. 18 AWG (0.82 mm²) and not less than 152 mm in length for connection of field installed wiring If supply wires exceed 60 C, marking indicates use of 75 C or 90 C wiring for supply connection as appropriate Equipment compatible with suitable trade sizes of conduits and cables Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation Conductors in power supply cords sized according to NEC and CEC, Part I Power supply cords and cord sets incorporate flexible cords suitable for the particular application Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source Adequate wire bending space and volume of field wiring compartment required to properly make the field connections Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse. 3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm²) or smaller Equipment is for building-in, provided with appliance inlet. Compliance shall be considered in the end system.

72 Issue Date: Page 7 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict conductor if provided with upturned lugs, cupped washer or equivalent retention Terminals accept wire sizes (gauge) used in the U.S. and Canada Terminals accept current-carrying conductors rated 125% of the equipment current rating Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V Vertically mounted disconnect devices oriented so up position of handle is "on" For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more Compartment housing high-pressure lamp marked to indicate risk of explosion Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit In addition to the IEC requirements, Direct Plug-in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30(Table NAE.6) Equipment using replenishable liquids marked to indicate type of liquid to be used Equipment that produces x-radiation and does not comply with under all conditions of servicing marked to indicate the presence of radiation where

73 Issue Date: Page 8 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict readily visible Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040 and REDR C1370). 4.7 Automated information storage equipment intended to contain more than 0.76 m³ of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system Equipment for use in environmental air space other than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL Equipment for installation in space used for environmental air as described in Sec (c) of the NEC provided with instructions indicating suitability for installation in such locations Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m² or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications Wire marked "VW-1" or "FT-1" considered equivalent Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections Touch current due to ringing voltage for equipment containing telecommunication network leads Overloading of SELV connectors and printed wiring board receptacles accessible to the operator Tests interrupted by opening of a component repeated two additional times Test interrupted by opening of wire or trace subject to certain conditions. 6 Specialized instructions provided for telephones that may be connected to a telecommunications network. 6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network. non-lasing LEDs exempt from 21CFR 1040.

74 Issue Date: Page 9 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict Special requirements for enameled wiring used as electrical separation provided between parts connected to telecommunication network and telecommunication circuitry intentionally isolated from network Digital line termination equipment (e.g., NCTE) subject to separation requirements. 6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection. 6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable. 6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C). 6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions. 6.5 Acoustic pressure from an ear piece less than 136 dba for short duration disturbances, and less than 125 dba for handsets, 118 dba for headsets, and 121 dba for insert earphones, for long duration disturbances. 7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC. H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act, REDR C1370. M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations. M.4 Special requirements for message waiting and similar telecommunications signals. NAC Equipment intended for use with a generic secondary protector marked with suitable instructions. NAC Equipment intended for use with a specific primary or secondary protector marked with suitable

75 Issue Date: Page 10 of 10 Report Reference # E A82-UL-1 SubClause Difference + Test Result - Remark Verdict instructions. NAF Household/Home Office Document Shredders NAF.1.7 Markings and instructions alert the user to key safety considerations related to use of shredders, including not intended to be used by children, avoid touching document feed opening, avoid clothes and hair entanglement, and avoid aerosol products. NAF Safety interlock cannot be inadvertently activated by the articulated accessibility probe (figure NAF.1). NAF.3.4 Provided with an isolating switch complying with 3.4.2, including 3 mm contact gap, with appropriate markings associated with the switch. NAF.4.4 Hazardous moving parts are not accessible to the user, as determined using the articulated accessibility probe (figure NAF.1) and the accessibility probe/wedge (figures NAF.2/NAF.3).

76 Issue Date: Page 1 of 9 Report Reference # E A82-UL-1 Enclosure Photographs Supplement Id Description 3-01 Overall View of Model DS Top View of Model DS Back view of Model DS Side View of Model DS Bottom View of Model DS Front View fof Model DS Internal View of Model DS Overall View of Model DS2900-3

77 Issue Date: Page 2 of 9 Report Reference # E A82-UL-1 Photographs ID 3-01

78 Issue Date: Page 3 of 9 Report Reference # E A82-UL-1 Photographs ID 3-02

79 Issue Date: Page 4 of 9 Report Reference # E A82-UL-1 Photographs ID 3-03

80 Issue Date: Page 5 of 9 Report Reference # E A82-UL-1 Photographs ID 3-04

81 Issue Date: Page 6 of 9 Report Reference # E A82-UL-1 Photographs ID 3-05

82 Issue Date: Page 7 of 9 Report Reference # E A82-UL-1 Photographs ID 3-06

83 Issue Date: Page 8 of 9 Report Reference # E A82-UL-1 Photographs ID 3-07

84 Issue Date: Page 9 of 9 Report Reference # E A82-UL-1 Photographs ID 3-08

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2006-05-11 Page 1 of 2 Report Reference # E212360-A19-UL-1 Amendment 2 2009-07-03 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference:

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-03-29 Page 1 of 10 Report Reference # E317867-A45- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-05-26 Page 1 of 2 Report Reference # E310405-A9-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Power Supplies for

More information

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT File E170507 Project 01ME11924 June 15, 2001 REPORT ON POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Globtek Inc. Northvale, NJ Copyright 2001 Underwriters Laboratories

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT File E132002 Project 07CA41555 Issued: August 29, 2007 Revised: June 22, 2015 REPORT On *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT *Copyright 2015 UL LLC Astec International Ltd. Kowloon,

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): COVER PAGE FOR TEST REPORT Power Supplies for Information Technology Equipment Including Electrical Business

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 55 Report No.:L611332L009 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-03-18 Page 1 of 11 Report Reference # E300305-A58-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ File E132594 Project 02ME17432 2003-02-09 REPORT on CORD CONNECTED CLASS 2 POWER UNITS Globtek Inc. Northvale, NJ Copyright 2003 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009.

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009. ELECTRICAL TESTING 839.01 Hermon Laboratories Ltd. Tel.+972 4 628 8001 Fax.+972 4 628 8277 SAFETY TEST REPORT ACCORDING TO: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, IEC 60950-1:2005 (Second Edition)

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF

More information

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences:

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences: age 3 of 106 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. re-production samples without serial

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-06-01 Page 1 of 15 Report Reference # E122103-A29-UL 2012-06-25 UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology

More information

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-07-30 Page 1 of 6 Report Reference # E313912-A35-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

A Test Lab Techno Corp.

A Test Lab Techno Corp. Report No. 1607CF12 age 1 of 52 TEST REORT AS/NZS60950.1:2011+A1:2013 Safety of Information Technology Equipment including Electrical business equipment Report Number.... : 1607CF12 Date of issue... :

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2011-01-12 Page 1 of 1 Report Reference # ASL10120310 COVER PAGE FOR TEST REPORT Test Item Description: Notebook PC Model/Type Reference: MS-16Y1 Rating(s): 19Vdc, 3.42A or 19Vdc, 4.74A Standards:

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-01-23 Page 4 of 57 Report Reference # E116994-A34-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 46 TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 160414015SZN-002 Date of issue... : May 09, 2016 Total number of pages... : 77 pages Applicant

More information

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements Page 1 of 49 Report Reference No....: 81790 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2009 TEST REPORT :2006 Information technology equipment Safety Part 1: General

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

File E Project 00SC October 9, 2000 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 00SC October 9, 2000 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT File E183744 Project 00SC10745 October 9, 2000 REPORT ON POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Sinpro Electronics Co., Ltd. Ping Tong Hsien, Taiwan Copyright

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

File E Project 00SC June 22, 2000 REPORT POWER SUPPLY ADAPTER INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 00SC June 22, 2000 REPORT POWER SUPPLY ADAPTER INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT File E183744 Project 00SC07511 June 22, 2000 REPORT ON POWER SUPPLY ADAPTER INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Sinpro Electronics Co. Ltd. Ping Tong Hsien, Taiwan

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

Investigation into UK socket-outlets incorporating USB charging points

Investigation into UK socket-outlets incorporating USB charging points Investigation into UK socket-outlets incorporating USB charging points Electrical Safety First investigated a number of commercially available UK socket-outlets incorporating USB ports, as a repeat of

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard Doc: ET 31(6126) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard UNINTERRUPTIBLE POWER SYSTEMS (UPS)

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number.... : TEST REORT Information technology equipment Safety art 1: General requirements Date of issue... : 7 March, 2017 Total number of pages...

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 248792 Date of issue... : 2013-11-25

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77 TECHNICAL REORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION SYSTEM NERA F77 ACCORDING TO EN 60950 (2000) REORT NO. 2002-3032 REVISION NO. 01 DET NORSKE VERITAS DET NORSKE VERITAS TECHNICAL

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: GLOBAL ADVANTAGE INTERNATIONAL TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of GUAGDOG EAST OWER CO., LTD. Uninterruptible ower Supply Model(s): EA99300,EA99250,EA99200 repared For : GUAGDOG EAST OWER CO., LTD. o.6 orthern Industry

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2003-09-25 Page 1 of 1 Report Reference # E203413-A17-CB-1 Test Item Description: Model/Type Reference: COVER PAGE FOR TEST REPORT Home Plug Device MS-6821 Rating(s): 100-240 Vac, 47-63 Hz,

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

File E Project 01ME August 14, 2001 REPORT

File E Project 01ME August 14, 2001 REPORT File E170507 Project 01ME16210 August 14, 2001 REPORT ON POWER SUPPLY ADAPTER FOR INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Globtek, Inc. Northvale, NJ Copyright 2001 Underwriters

More information

Copy of marking plate. Page 2 of 50 Report No. TRS

Copy of marking plate. Page 2 of 50 Report No. TRS Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Issued to: Rotork Controls Inc. 675 Mile Crossing Blvd Rochester, NY 14624 USA Attention: Matt Cogill The products listed below are eligible to bear the CSA Mark shown

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1712057S.50A Date of issue... : 2017-04-13 Total number

More information

LS200 Series Instruction Manual

LS200 Series Instruction Manual LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

E-15 Uninterruptible Power Systems (UPS)

E-15 Uninterruptible Power Systems (UPS) Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,

More information

BATTERY CHARGERS NO. 3

BATTERY CHARGERS NO. 3 Date: January 10, 1992 BATTERY CHARGERS NO. 3 To: Subject: Manufacturers of Commercial/Industrial Battery Chargers Expansion of CSA Certification Service for Power Supplies to Include Low Voltage, Outdoor

More information

LOW VOLTAGE DIRECTIVE TEST REPORT IEC / EN , First Edition Information technology equipment Safety Part 1: General requirements

LOW VOLTAGE DIRECTIVE TEST REPORT IEC / EN , First Edition Information technology equipment Safety Part 1: General requirements page 1 of 39 Report No.: L7D1808L658 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1 / EN 60950-1, First Edition Information technology equipment Safety Part 1: General requirements Report Reference No....

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

File E87247 Project 07CA July 19, 2008 REPORT UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT

File E87247 Project 07CA July 19, 2008 REPORT UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT File E87247 Project 07CA43188 July 19, 2008 REPORT ON UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT Copyright 2008 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company

More information

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost

Silvertel. Ag Features. 2 Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low cost Silvertel V2.5 Feb 2014 Datasheet Pb 1 Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 14mm (H) Low cost Input voltage range 36V to 57V Minimal (low cost) external components required

More information

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise

Silver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise Silver T E L E C O M V2.0 Aug 2008 Pb. Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 4mm (H) Low output ripple and noise Input voltage range 36V to 57V Only one low cost external decoupling

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....:

More information