Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.
|
|
- Miles Ross
- 5 years ago
- Views:
Transcription
1
2 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: Tested by (+ signature)...: see cover sheet... Witnessed by (+ signature)...: see cover sheet... Supervised by (+ signature)...: see cover sheet... Approved by (+ signature)...: see cover sheet... Date of issue...: see cover sheet Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan Testing location / procedure...: TL SMT WMT TM Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan Applicant s name...: Coming Data Co., Ltd Address...: 5F-1, No. 13, Wu Cheng 1st Rd. Hsin Chung City, Taipei Hsien, Test specification: Taiwan Standard...: :1990 Test procedure...: TÜV Rheinland Test approval Non-standard test method...: Test Report Form No....: EN50075B TRF originator...: OVE Master TRF...: dated Copyright 2004 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description...: EU lug Trade Mark...: Manufacturer...: Coming Data Co., Ltd Model and/or type reference...: C1220, C1215, C1210, C0920, C0915, C0540, C0530 Ratings...: I/: V~, 50/60Hz, 0.8A max.
3 age 2 of 11 Copy of marking plates
4 age 3 of 11 hotos for plug portion Soldering connection. in portion of the plug are fixed into the body by screw terminal. ossible test case verdicts: - test case does not apply to the test object...: - test object does meet the requirement...: (ass) - test object does not meet the requirement...: F(Fail)
5 age 4 of 11 Testing...: Date of receipt of test item...: Feb. 27, 2007 Date (s) of performance of tests...: Feb. 27, 2007 Apr. 23, 2007 General remarks: The present Test Report is not valid as a Test Report according to a Mutual Recognition Agreement (i.e. CCA, ENEC) unless signed by an approved Testing Laboratory and appended to a corresponding Certificate issued by a national Certification Body, signatory to the relevant Scheme. The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. General product information: This EU plug portion is integrated with Direct lug-in Device, C12XY (C1220, C1215, C1210, C0920, C0915, C0540, C0530)
6 age 5 of 11 First testing set: Sample No. 1, 2 and 3 5 RATING 2.5 A AC 250 V V~, 0.8A max. 6 MARKING 6.1/.2 Rated current: 2.5 A 0.8A max. Rated voltage: 250 V V~ Nature of supply: ~ ~ Name of manufacturer or responsible vendor Type reference C1220, C1215, C1210, C0920, C0915, C0540, C Symbol for Class II construction not allowed Marked on Switch ower Supply. 6.4 Marking durable Marked on Switch ower Supply. Easily legible Test: 15 s water and 15 s petroleum spirit Marked on Switch ower Supply. Marked on Switch ower Supply. 7 DIMENSIONS Compliance with Standard Sheet 1 Complied. 1) Diagonal dimension of plug base 26.1 ± 0.5 mm C) 26.0 Top 26.4 Bottom mm Width of plug base 13.7 ± 0.7 mm D) 13.9 Top 14.1 Bottom mm Length of plug base 35.3 ± 0.7 mm E) 35.1 Top 35.3 Bottom mm These dimensions shall not be exceeded within a distance of 18mm from the engagement face of the plug along gripping surface. 18 mm min. F) 18.1 mm
7 age 6 of 11 The above dimensions shall be kept from the engagement face of the plug for min 4mm along gripping surface. 4mm min. G) 18.1 mm 2) 3) Between two pins (pin base) mm 18.5 mm Between two pins (pin top) mm 17.3 mm Diameter of pin (metallic part) 4 ± 0.06 mm H) 3.98 L 3.96 R mm The edges of the metal parts shall be chamfered or rounded off Complied. Diameter of pin (pin base) max. 4.0 mm 3.7 L 3.8 R mm Diameter of pin (middle part) max. 3.8 mm I) 3.4 L 3.4 R mm Length of pin except metal part mm J) 10.2 L 10.4 R mm in length 19 ± 0.5 mm K) 18.8 L 19.1 R mm Shape of pin end Rounded. Gauges of figures 1 and 2 Complied.
8 age 7 of 11 8 ROTECTION AGAINST ELECTRIC SHOCK 8.1 Test finger of fig. 3 After subjected a force of 75N for 60s, no impair occurred. Ambient temperature 35 C Force: 75 N Complied. 8.2 Gauge of fig. 4 The gauge did not come into contact with the engagement face of the plug. Ambient temperature: 35 ± 2 C 35 C 8.3 External parts of insulating material Complied. Material used: see table CONSTRUCTION 9.1 Non-rewirable plug Non-rewirable. 9.2 Switches, fuses and lampholders not incorporated No such kind of device incorporated. 9.3 ins of plug solid Complied. Checked according to clause ins of plug locked against rotation Complied. Checked according to clause 13.1 and in portion of the plug are fixed into the body by screw terminal. See also photo of plug portion 9.5 Effective permanent connections: - soldered, welded, crimped Soldering connection - screwed and snap-on connections not used Complied. - presoldered flexible conductor for crimping not permitted Complied. 9.6 Gripping operation: - length 55 mm Integrated with Switch ower Supply. - ball test Integrated with Switch ower Supply.
9 age 8 of RESISTANCE TO HUMIDITY No damage after 48 h R.H.: 95%, T ambient: 25 C, for 48 h 11 INSULATION RESISTANCE AND ELECTRIC STRENGTH 11.1 Resistance 5 MΩ (500 V, 1 min) 1000MΩ 11.2 Electric strength test (2000 V, 1 min): no flashover or breakdown No flashover or breakdown. 12 FLEXIBLE CORDS AND THEIR CONNECTION 12.1 Cords in compliance with HD 21.5 or HD 22.4 Non-flexible cords. 13 MECHANICAL STRENGTH 13.1 Compression test (150 N, 5 min) No deformation or any undue change of dimensions Tumbling barrel test: number of falls...: According to EN 60950, this test considered not applicable. Torque test on pins (0.4 Nm, 1 min) The pins did not turn after torque test Abrasion test ( movements): no damage No damage. 14 RESISTANCE TO HEAT AND TO AGEING Heating test (100 C, 1 h): no damage No damage a) ressure test (80 C, 20 N, 1 h): no damage Considered ball pressures test is severer than the pressure test, so the enclosure was subjected to ball pressure test instead. (80 C, 1 h). See also table b) ressure test (125 C, 20 N, 1 h): no damage As considered for ensure the safety aspect, the insulation material retaining the current-carrying parts was subjected to the ball pressure test (125 C, 1 h).
10 age 9 of CURRENT-CARRYING ARTS AND CONNECTIONS 15.1 Connections withstand the mechanical stresses occurring in normal use Complied Contact pressure Complied Material of current-carrying parts C3602, %; C3603BD, % 16 CREEAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION Creepage distances and clearances between live parts 3 mm Creepage distances and clearances between live parts and accessible external surfaces 3 mm Distance through insulation 1.5 mm Creepage: 17.8 mm Clearance: 14.1 mm Creepage: 14.8 mm Clearance: 12.1 mm Integrated with Switch ower Supply. 4.6 mm from the live parts to accessible engagement surface. 17 RESISTANCE OF INSULATING MATERIAL TO ABNORMAL HEAT AND TO FIRE Glow-wire test (750 C for parts necessary to retain current-carrying parts in position): no visible flame, no sustained glowing or flames and glowing extinguish within 30 s after removal of glow-wire Glow-wire test (650 C for other parts): no visible flame, no sustained glowing or flames and glowing extinguish within 30 s after removal of glow-wire 750 C of glow-wire test was subjected. Flames and glowing at the insulation material retaining the current-carrying part extinguish within 30 s after removal of glow-wire. No ignition of tissue paper. See table C of glow-wire test was subjected. Flames and glowing at the plug enclosure extinguish within 30 s after removal of glow-wire. No ignition of tissue paper. See table 8.3
11 age 10 of 11 Second testing set: Sample No. 4, 5 and Moulded-on plugs ull test (100 times, 50 N, 1 s) Torque test (1 min): cross-sectional area 0.5 mm², 0.1 Nm: displacement 2 mm; no break in electrical connections cross-sectional area 0.75 mm², 0.15 Nm: displacement 2 mm; no break in electrical connections Integrated with Switch ower Supply Mechanical strength ull test with steel plate on pin (40 N, 70 C, 1 min): displacement of pin 1 mm After the test, no pin displacement occurred. 14 Resistance to heat and to ageing 14.2 Heating test (70 C, 168 h): no damage, no cracks visible No cracks visible. ressure test (5 N): no traces No traces. Third testing set: Sample No. 7, 8 and Flexible cords and their connection Flexing test ( flexings, 2.5 A, AC 250 V) - 10 N (cross-sectional area 0.75 mm²) - 20 N (cross-sectional area > 0.75 mm²) no damage Voltage drop 10 mv test current: - 1 A with H03 VH-Y A with other cords No flexible cord used.
12 age 11 of TABLE: list of critical components Object/part No. Enclosure Material AC lug in Holding Material Manufacturer/ trademark GE lastics Global roducts GE lastics Global roducts Type/model Technical data Standard Mark(s) of conformity SE1X(f1) V-1, 105 C UL 94 E61759 SE1X(f1) V-1, 105 C UL 94 E TABLE: ball pressure test of Insulating material allowed impression diameter (mm) : 2mm art Type/model Test temperature ( C) Impression diameter (mm) Enclosure Material SE1X(f1), GE lastics Global roducts AC lug in Holding Material SE1X(f1), GE lastics Global roducts
ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue
ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE
More informationInstallation Couplers intended for permanent connection in fixed installation
Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26
More informationTEST REPORT IEC Connectors Safety requirements and tests
IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of
More informationTEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires
TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...
More informationTEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements
TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff
More informationTEST REPORT IEC Connectors Safety requirements and tests
IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of
More informationAmendment to Test Report
Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,
More informationLIA Laboratories Limited
LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):
More informationLIA Laboratories Limited
LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,
More informationAnnex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.
TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex
More informationTEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors
r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements
More informationTEST REPORT EN LED modules for general lighting Safety specifications
TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant
More informationZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :
Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report
More informationTEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test )
TEST REPORT IEC 60529 Degrees of protection provided by enclosures ( Partially for IP65 test ) Report reference No...: L113061055 Compiled by (+ signature)...: see cover sheet... Approved by (+ signature)...:
More informationLIA Laboratories Limited
LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,
More informationInstallation Couplers intended for permanent connection in fixed installation
age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....
More informationPage 3 of 34 Report No Part I
www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are
More informationPage 3 of 32 Report No Summary of testing:
age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.
More informationPage 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.
12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...
More informationTEST REPORT. IEC 62133: 2012 (Second Edition)
Test Report issued under the responsibility of: TEST REORT, Second Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...
More informationTEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements
TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing
More informationTest Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...
Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and
More informationTEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7
TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample
More informationTest Report No. 55S071315/ZHY/PKS dated 10 JUL 2007
Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY
More informationTEST REPORT IEC LED modules for general lighting Safety specifications
Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...
More informationAmendment to Test Report
Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294
More informationLVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.
LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.
More informationTEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...
More informationTest Report issued under the responsibility of: Report Number...:
Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and
More informationTEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires
Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:
More informationL7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD
age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated
More informationTEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches
TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016
More informationAS/NZS AS/NZS
TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :
More informationTEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements
TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 70.410.14.127.01-01 Date of issue... : 2014-07-03 Total number of pages... 61
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015
More informationTEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools
age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October
More informationSCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU
age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements
More informationTEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements
Test Report issued under the responsibility of TEST REORT IEC 60884-1 lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 2228900-1520-0001/175202
More informationTest report for mechanical switches according to IEC Switches for appliances Part 1: General requirements
Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...
More informationTest Report issued under the responsibility of: BA-10CA08002-K-1 Date of issue... : Total number of pages Report Reference No...
Test Report issued under the responsibility of: TEST REPORT IEC 62133, First Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed
More informationTest Report No EEC12-03/MLM dated 27 MAR 2012
Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD SB te Ltd. In addition, this report is
More informationTEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000
Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...
More informationTEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools
age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total
More informationTest Report No. 55S070647/MLM/PKS dated 27 APR 2007
Test Report No. 55S070647/MLM/KS dated 27 AR 2007 Note: This report is issued subject to TÜV SÜD SB Corporation's "Terms and Conditions Governing Technical Services". The terms and conditions governing
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires
TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements Section 1: Fixed general purpose luminaires Report Number.... : 64.140.11.02922.03 Date of issue... : 2015-02-02 Total number of pages...
More informationSHA-001 Date of issue...: Total number of pages Report Reference No...:
TEST REORT lugs and socket-outlets for household and similar purposes art 2-1: General requirements on plugs and portable socket-outlets Report Reference No....: 130600884SHA-001 Date of issue...: 2013-07-09
More informationIntertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.
Test Report issued under the responsibility of: TEST REORT IEC 62133, First Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed
More informationTEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD
Report o.: BST14090471Y-1SR-2 SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD TEST REORT repared For : SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD 4F,Building A,YouXinDa Industrial Area, GenYu Road,TianLiao
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting
Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date
More informationTest Report No EEC12-02/MLM dated 29 MAR 2012
Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD SB te Ltd. In addition, this report is
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total
More informationNCB Intertek Testing Services NA, Inc.
Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General
More informationTEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills
Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools art 2: articular requirements for drills and impact drills Report reference No.... : 3130837.50A
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
Test Report issued under the responsibility of: TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Number.... : 17041854 001 Date of
More informationTest Report issued under the responsibility of:
age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in
More informationLuminaire for road and street lighting. Approved by / Authorized Signatory:
Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...
More informationTEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules
age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic
More informationTEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements
Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment
More informationThis standard covers the requirements of lighting chains. This standard covers only the safety requirements.
FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the
More informationTest Report issued under the responsibility of:
age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in
More informationPart 1: General requirements for basic safety and essential performance
Test Report issued under the responsibility of: TEST REORT art 1: General requirements for basic safety and essential performance Report Number.... : 130501061SHA-001 Date of issue... : 2013-07-01 Total
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires
Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular
More informationTEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements
Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment
More informationTEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights
TEST REORT EN 60598-2-21 Luminaires art 2: articular requirements Section 21: Rope Lights Report reference No.... : ED170727001S Tested by... : Coral Chen Approved by... : Kobe Mai Date of issue... : August
More informationShenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)
Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB13035196 Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR
More informationTEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L
TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power
More information< > Page 2 of 84
age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes
More informationReport o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno
Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct
More informationTEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans
Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires
age 1 of 40 TEST REORT IEC 60598-2-2 Luminaires art 2: articular requirements Section 2: Recessed luminaires Report Number.... : 7040216100405-00 Date of issue... : 2016-11-18 Total number of pages...
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No....: TGM-VA EE32453 SFT Date of issue...
More informationAPPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82
age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang
More informationTest Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND
Reference No.: WTF16F0961094C age 2 of 5 Test Results: Test Item(s) Unit Test Result No.1 MDL Maximum Allowable Limit Lead (b) % ND 0.0002 See comment if > 0.004 % Cadmium (Cd) % ND 0.0002 0.002 Mercury
More informationLVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S
Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationWith Compliments PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : : 1006
For the Attention of: Mr Ian Davies Mideas Limited 12 Openshaw Drive Blackburn Lancashire BB1 8RH With Compliments DATE REPORT ISSUED: 10/11/2006 PLEASE FIND ENCLOSED OUR REPORT REFERENCE ALC E : 99316
More informationPage 2 of 23 UNT150420C11
Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...
More informationShenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa
Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz
More informationLow-voltage fuses: fuse systems A, B and F. Test specification: IEC (2013) Edition together with : IEC (2009) Edition 4.
Test report form: IEC HD 60269-2 Edition 5.0 Document date: 27 th October 2014 Test object: Low-voltage fuses: fuse systems A, B and F Test specification: IEC 60269-2 (2013) Edition 5.0 - together with
More informationIEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):
More informationTEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches
Test Report issued under the responsibility of: TEST REPORT Switches for appliances Part 2-1: Particular requirements for cord switches Report Reference No.... : SH11080876-001 Date of issue... : 2012-02-23
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
Test Report issued under the responsibility of: TEST REORT art 1: General requirements for basic safety and essential performance Report Number.... : 160900306SHA-001 Date of issue... : 2016-10-27 Total
More informationTEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
TEST REORT EN 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No...: 3007562.50-QUA/LI Date of issue...: 2011-03-28 Total number of pages...
More informationAustralian/New Zealand Standard
AS/NZS 3112:2011 AS/NZS 3112:2011 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets AS/NZS 3112:2011 This Joint Australian/New Zealand Standard was prepared by Joint
More informationTest Report issued under the responsibility of: Report Number... : Date of issue... : Total number of pages...
Test Report issued under the responsibility of: TEST REORT IEC 62133 Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells,
More informationSGS Australia Pty Ltd
TEST REPORT AS/NZS 60598.2.2:2001 Luminaires Part 2: Particular requirements Recessed luminaires Report Reference No....: S08007 Approved by (+ signature)...: I Absolom Date of issue...: Thursday, 31 January
More information