1 Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No....: TGM-VA EE32453 SFT Date of issue... : Total number of pages ages CB Testing Laboratory... : Staatliche Versuchsanstalt TGM Elektrotechnik und Elektronik Address... : A-1200 Wien, Wexstrasse Applicant s name... : Address... : MARELI. LTD 722 STR., KV. LULIN, SOFIA 1360, BULGARIA Test specification: Standard... : Test procedure... : Non-standard test method..: :1979+A1:1987 used in conjunction with IEC :2008 CB, ENEC Test Report Form No.... : Test Report Form(s) Originator... : Master TRF... : IEC60598_2_1B Intertek Semko AB Copyright 2009 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this Test Report Form is used by non-iecee members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description...: Trade Mark...: Manufacturer...: Model/Type reference...: Fixed general purpose luminaires with tubular fluorescent lamps MARELI. LTD MARELI. LTD See Type code Ratings... : 230V 50Hz or V 50-60Hz, Cl.I, i, I20 see Type code

2 age 2 of 48 TGM-VA EE SFT Testing procedure and testing location: CB Testing Laboratory: Staatliche Versuchsanstalt TGM Elektrotechnik und Elektronik Testing location/ address...: A-1200 Wien, Wexstrasse Associated CB Laboratory: Testing location/ address... : Tested by (name + signature)...: Ing.Noori Approved by (+ signature)...: Dr.Nitsche Testing procedure: TM Tested by (name + signature)...: Approved by (+ signature)...: Testing location/ address...: Testing procedure: WMT Tested by (name + signature)...: Witnessed by (+ signature)...: Approved by (+ signature)...: Testing location/ address...: Testing procedure: SMT Tested by (name + signature)...: Approved by (+ signature)...: Supervised by (+ signature)...: Testing location/ address...: Testing procedure: RMT Tested by (name + signature)...: Approved by (+ signature)...: Supervised by (+ signature)...: Testing location/ address...:

3 age 3 of 48 TGM-VA EE SFT Summary of testing: Full test conducted on type S4586I20D, TSRE2146I20DW, VS4186I20VI, ES4181I20S, ES2581I20D, S 2586I20D, TSRE 2286I20DW and TSRE4146I20DW representing also for the other types ictures see page Tests performed (name of test and test clause): Testing location: Staatliche Versuchsanstalt TGM Elektrotechnik und Elektronik A-1200 Wien, Wexstrasse Summary of compliance with National Differences: Copy of marking plate

4 age 4 of 48 TGM-VA EE SFT Test item particulars... : Classification of installation and use... : Class I Supply Connection... : Screw less terminal... :... : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F (Fail) Testing... : Date of receipt of test item... : Date (s) of performance of tests... : Cw 30/ /2011 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC General product information: Luminaires for wall or ceiling mounting. Housing made of sheet steel with a thickness of o,6 mm of white (RAL 9003) or grey (RAL 9006) polymer coating and with grid. Lamp holder G5, G13 Type of connection: screw less-terminals.

5 age 5 of 48 TGM-VA EE SFT 1.2 (0) GENERAL TEST REQUIREMENTS 1.2 (0.1) Information for luminaire design considered Standard Yes No 1.2 (0.3) More sections applicable... : Yes No 1.4 (2) CLASSIFICATION 1.4 (2.2) Type of protection (Class 0 excluded)... : Class I 1.4 (2.3) Degree of protection (Requirement: Ordinary)... : I (2.4) Luminaire suitable for direct mounting on normally flammable surfaces... : Luminaire not suitable for direct mounting on normally flammable surfaces... : Yes No Yes No 1.4 (2.5) Luminaire for normal use... : Yes No Luminaire for rough service... : Yes No 1.5 (3) MARKING 1.5 (3.2) Mandatory markings osition of the marking Format of symbols/text 1.5 (3.3) Additional information Language of instructions 1.5 (3.3.1) Combination luminaires 1.5 (3.3.2) Nominal frequency in Hz 1.5 (3.3.3) Operating temperature 1.5 (3.3.4) Symbol or warning notice 1.5 (3.3.5) Wiring diagram 1.5 (3.3.6) Special conditions 1.5 (3.3.7) Metal halide lamp luminaire warning 1.5 (3.3.8) Limitation for semi-luminaires 1.5 (3.3.9) ower factor and supply current 1.5 (3.3.10) Suitability for use indoors 1.5 (3.3.11) Luminaires with remote control 1.5 (3.3.12) Clip-mounted luminaire warning 1.5 (3.3.13) Specifications of protective shields

6 age 6 of 48 TGM-VA EE SFT 1.5 (3.3.14) Symbol for nature of supply 1.5 (3.3.15) Rated current of socket outlet 1.5 (3.3.16) Rough service luminaire 1.5 (3.3.17) Mounting instruction for type Y, type Z and some type X attachments 1.5 (3.3.18) Non-ordinary luminaires with VC cable 1.5 (3.3.19) rotective conductor current in instruction if applicable 1.5 (3.3.20) rovided with information if not intended to be mounted within arms reach 1.5 (3.4) Test with water Test with hexane Legible after test Label attached 1.6 (4) CONSTRUCTION 1.6 (4.2) Components replaceable without difficulty 1.6 (4.3) Wireways smooth and free from sharp edges 1.6 (4.4) Lampholders 1.6 (4.4.1) Integral lampholder 1.6 (4.4.2) Wiring connection 1.6 (4.4.3) Lampholder for end-to-end mounting 1.6 (4.4.4) ositioning - pressure test (N)... : After test the lampholder comply with relevant standard sheets and show no damage After test on single-capped lampholder the lampholder have not moved from its position and show no permanent deformation - bending test (N)... : After test the lampholder have not moved from its position and show no permanent deformation 1.6 (4.4.5) eak pulse voltage 1.6 (4.4.6) Centre contact 1.6 (4.4.7) arts in rough service luminaires resistant to tracking 1.6 (4.4.8) Lamp connectors

7 age 7 of 48 TGM-VA EE SFT 1.6 (4.4.9) Caps and bases correctly used 1.6 (4.5) Starter holders Starter holder in luminaires other than class II Starter holder class II construction 1.6 (4.6) Terminal blocks Tails Unsecured blocks 1.6 (4.7) Terminals and supply connections 1.6 (4.7.1) Contact to metal parts 1.6 (4.7.2) Test 8 mm live conductor Test 8 mm earth conductor 1.6 (4.7.3) Terminals for supply conductors 1.6 ( ) Welded connections: - stranded or solid conductor - spot welding - welding between wires - Type Z attachment - mechanical test according to electrical test according to heat test according to and (4.7.4) Terminals other than supply connection 1.6 (4.7.5) Heat-resistant wiring/sleeves 1.6 (4.7.6) Multi-pole plug - test at 30 N 1.6 (4.8) Switches: - adequate rating - adequate fixing - polarized supply - compliance with for electronic switches 1.6 (4.9) Insulating lining and sleeves 1.6 (4.9.1) Retainement Method of fixing... : construction 1.6 (4.9.2) Insulated linings and sleeves

8 age 8 of 48 TGM-VA EE SFT Resistant to a temperature > 20 C to the wire temperature or a) & c) Insulation resistance and electric strength b) Ageing test. Temperature ( C)... : 1.6 (4.10) Insulation of Class II luminaires 1.6 (4.10.1) No contact, mounting surface accessible metal parts wiring of basic insulation Safe installation fixed luminaires Capacitors and switches Interference suppression capacitors according to IEC (4.10.2) Assembly gaps: - not coincidental - no straight access with test probe 1.6 (4.10.3) Retainment of insulation: - fixed - unable to be replaced; luminaire inoperative - sleeves retained in position - lining in lampholder 1.6 (4.11) Electrical connections 1.6 (4.11.1) Contact pressure 1.6 (4.11.2) Screws: - self-tapping screws - thread-cutting screws 1.6 (4.11.3) Screw locking: - spring washer - rivets 1.6 (4.11.4) Material of current-carrying parts 1.6 (4.11.5) No contact to wood or mounting surface 1.6 (4.11.6) Electro-mechanical contact systems 1.6 (4.12) Mechanical connections and glands 1.6 (4.12.1) Screws not made of soft metal Screws of insulating material Torque test: torque (Nm); part... : 1,2 Nm case Torque test: torque (Nm); part... :

9 age 9 of 48 TGM-VA EE SFT 1.6 (4.12.2) Screws with diameter < 3 mm screwed into metal 1.6 (4.12.4) Locked connections: - fixed arms; torque (Nm)... : - lampholder; torque (Nm)... : - push-button switches; torque 0,8 Nm... : 1.6 (4.12.5) Screwed glands; force (Nm)... : 1.6 (4.13) Mechanical strength 1.6 (4.13.1) Impact tests: - fragile parts; energy (Nm)... : - other parts; energy (Nm)... : 0,35 Nm 1) live parts 2) linings 3) protection 4) covers 1.6 (4.13.3) Straight test finger 1.6 (4.13.4) Rough service luminaires - I54 or higher a) fixed b) hand-held c) delivered with a stand d) for temporary installations and suitable for mounting on a stand 1.6 (4.13.6) Tumbling barrel 1.6 (4.14) Suspensions and adjusting devices 1.6 (4.14.1) Mechanical load: A) four times the weight S4586I20D 3,809kg 4x8,055 =32,220kg TSRE2146I20DW 2,147kg 4x2,147 =8,588 kg VS4186I20VI 2,347kg 4x2,347 =9,388 kg ES4181I20S 4,480kg 4x4,480 =17,920kg ES2581I20D 6,190kg 4x6,190 =24,760kg TSRE4146I20DW 3,630kg 4x3,630 =14,520kg TSRE 2286I20DW 3,809kg 4x3,809 =15,236kg S 2586I20D 3,824kg 4x3,824=15,296kg B) torque 2,5 Nm C) bracket arm; bending moment (Nm)... : D) load track-mounted luminaires

10 age 10 of 48 TGM-VA EE SFT E) clip-mounted luminaires, glass-shelve. Thickness (mm)... : Metal rod. diameter (mm)... : Fixed luminaire or independent control gear without fixing devices 1.6 (4.14.2) Load to flexible cables Mass (kg)... : Stress in conductors (N/mm²)... : Mass (kg) of semi-luminaire... : Bending moment (Nm) of semi-luminaire... : 1.6 (4.14.3) Adjusting devices: - flexing test; number of cycles... : - strands broken - electric strength test afterwards 1.6 (4.14.4) Telescopic tubes: cords not fixed to tube; no strain on conductors 1.6 (4.14.5) Guide pulleys 1.6 (4.14.6) Strain on socket-outlets 1.6 (4.15) Flammable materials: - glow-wire test 650 C - spacing 30 mm - screen withstanding test of screen dimensions - no fiercely burning material - thermal protection - electronic circuits exempted 1.6 (4.15.2) Luminaires made of thermoplastic material with lamp control gear a) construction b) temperature sensing control c) surface temperature 1.6 (4.16) Luminaires for mounting on normally flammable surfaces No lamp control gear (compliance with Section 12) 1.6 (4.16.1) Lamp control gear spacing: - spacing 35 mm - spacing 10 mm

11 age 11 of 48 TGM-VA EE SFT 1.6 (4.16.2) Thermal protection: - in lamp control gear - external - fixed position - temperature marked lamp control gear 1.6 (4.16.3) Design to satisfy the test of 12.6 (see 12.6) 1.6 (4.17) Drain holes Clearance at least 5 mm 1.6 (4.18) Resistance to corrosion: 1.6 (4.18.1) - rust-resistance 1.6 (4.18.2) - season cracking in copper 1.6 (4.18.3) - corrosion of aluminium 1.6 (4.19) Ignitors compatible with ballast 1.6 (4.20) Rough service vibration 1.6 (4.21) rotective shield: 1.6 (4.21.1) Shield fitted Shield of glass if tungsten halogen lamps 1.6 (4.21.2) articles from a shattering lamp not impair safety 1.6 (4.21.3) No direct path 1.6 (4.21.4) Impact test on shield Glow-wire test on lamp compartment 1.6 (4.22) Attachments to lamps 1.6 (4.23) Semi-luminaires comply Class II 1.6 (4.24) UV radiation for tungsten halogen lamps and metal halide lamps (Annex ) 1.6 (4.25) No sharp point or edges 1.6 (4.26) Short-circuit protection: 1.6 (4.26.1) Uninsulated accessible SELV parts 1.6 (4.26.2) Short-circuit test 1.6 (4.26.3) Test chain according to Figure (11) CREEAGE DISTANCES AND CLEARANCES Working voltage (V)... : 230V, V

12 age 12 of 48 TGM-VA EE SFT Voltage form Sinusoidal Non-sinusoidal TI < 600 > 600 Impulse withstand category (Normal category II) (Category III Annex U) Rated pulse voltage (kv)... : (1) Current-carrying parts of different polarity: cr (mm); cl (mm)... : (2) Current-carrying parts and accessible parts: cr (mm); cl (mm)... : (3) arts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm)... : (4) Outer surface of cable where it is clamped and metal parts: cr (mm); cl (mm)... : Category II Category III 15,1 / 14,3 19,2 / 18,3 (5) Not used (6) Current-carrying parts and supporting surface: cr (mm); cl (mm)... : 24,7 / 22,3 1.8 (7) ROVISION FOR EARTHING 1.8 ( ) 1.8 ( ) Accessible metal parts Metal parts in contact with supporting surface Resistance < 0,5 Ω Self-tapping screws used Thread-forming screws Thread-forming screw used in a grove Earth makes contact first Earth continuity in joints etc. 1.8 (7.2.4) Locking of clamping means Compliance with Terminal blocks with integrated screwless earthing contacts tested according Annex V 1.8 (7.2.5) Earth terminal integral part of connector socket 1.8 (7.2.6) Earth terminal adjacent to mains terminals 1.8 (7.2.7) Electrolytic corrosion of the earth terminal

13 age 13 of 48 TGM-VA EE SFT 1.8 (7.2.8) Material of earth terminal Contact surface bare metal 1.8 (7.2.10) Class II luminaire for looping-in Double or reinforced insulation to functional earth 1.8 (7.2.11) Earthing core coloured green-yellow Length of earth conductor 1.9 (14) SCREW TERMINALS Separately approved; component list (see Annex 1) art of the luminaire (see Annex 3) 1.9 (15) SCREWLESS TERMINALS AND ELECTRICAL CONNECTIONS Separately approved; component list (see Annex 1) art of the luminaire (see Annex 4) 1.10 (5) EXTERNAL AND INTERNAL WIRING 1.10 (5.2) Supply connection and external wiring 1.10 (5.2.1) Means of connection... : 1.10 (5.2.2) Type of cable... : Nominal cross-sectional area (mm²)... : Cables equal to IEC or IEC (5.2.3) Type of attachment, X, Y or Z 1.10 (5.2.5) Type Z not connected to screws 1.10 (5.2.6) Cable entries: - suitable for introduction - adequate degree of protection 1.10 (5.2.7) Cable entries through rigid material have rounded edges 1.10 (5.2.8) Insulating bushings: - suitably fixed - material in bushings - material not likely to deteriorate - tubes or guards made of insulating material 1.10 (5.2.9) Locking of screwed bushings

14 age 14 of 48 TGM-VA EE SFT 1.10 (5.2.10) Cord anchorage: 1.10 ( ) 1.10 ( ) 1.10 ( ) - covering protected from abrasion - clear how to be effective - no mechanical or thermal stress - no tying of cables into knots etc. - insulating material or lining Cord anchorage for type X attachment: a) at least one part fixed b) types of cable c) no damaging of the cable d) whole cable can be mounted e) no touching of clamping screws f) metal screw not directly on cable g) replacement without special tool Glands not used as anchorage Labyrinth type anchorages Adequate cord anchorage for type Y and type Z attachment Tests: - impossible to push cable; unsafe - pull test: 25 times; pull (N)... : - torque test: torque (Nm)... : - displacement 2 mm - no movement of conductors - no damage of cable or cord 1.10 (5.2.11) External wiring passing into luminaire 1.10 (5.2.12) Looping-in terminals 1.10 (5.2.13) Wire ends not tinned Wire ends tinned: no cold flow 1.10 (5.2.14) Mains plug same protection Class III luminaire plug 1.10 (5.2.16) Appliance inlets (IEC 60320) Appliance couplers of class II type

15 age 15 of 48 TGM-VA EE SFT 1.10 (5.2.17) No standardized interconnecting cables properly assembled 1.10 (5.2.18) Used plug in accordance with - IEC other standard 1.10 (5.3) Internal wiring 1.10 (5.3.1) Internal wiring of suitable size and type Through wiring - not delivered/ mounting instruction - factory assembled - socket outlet loaded (A)... : - temperatures... : (see Annex 2) Green-yellow for earth only 1.10 ( ) Internal wiring connected directly to fixed wiring Cross-sectional area (mm²)... : 0,75mm² Insulation thickness Extra insulation added where necessary 1.10 ( ) Internal wiring connected to fixed wiring via internal current-limiting device Adequate cross-sectional area and insulation thickness 1.10 ( ) Double or reinforced insulation for class II 1.10 ( ) Conductors without insulation 1.10 ( ) SELV current-carrying parts 1.10 ( ) Insulation thickness other than VC or rubber 1.10 (5.3.2) Sharp edges etc. No moving parts of switches etc. Joints, raising/lowering devices Telescopic tubes etc. No twisting over (5.3.3) Insulating bushings: - suitable fixed - material in bushings - material not likely to deteriorate - cables with protective sheath

16 age 16 of 48 TGM-VA EE SFT 1.10 (5.3.4) Joints and junctions effectively insulated 1.10 (5.3.5) Strain on internal wiring 1.10 (5.3.6) Wire carriers 1.10 (5.3.7) Wire ends not tinned Wire ends tinned: no cold flow 1.11 (8) ROTECTION AGAINST ELECTRIC SHOCK 1.11 (8.2.1) Live parts not accessible with standard test finger Basic insulated parts not used on the outer surface without appropriate protection Basic insulated parts not accessible with standard test finger on portable and adjustable luminaires Basic insulated parts not accessible with Ø 50 mm probe from outside, within arms reach, on wall-mounted luminaires Lamp and starterholders in portable and adjustable luminaires comply with double or reinforced insulation requirements Basic insulation only accessible under lamp or starter replacement rotection in any position Double-ended tungsten filament lamp Insulation lacquer not reliable Double-ended high pressure discharge lamp Relevant warning according to fitted to the luminaire 1.11 (8.2.2) ortable luminaire adjusted in most unfavourable position 1.11 (8.2.3.a) Class II luminaire: - basic insulated metal parts not accessible during starter or lamp replacement - basic insulation not accessible other than during starter or lamp replacement - glass protective shields not used as supplementary insulation 1.11 (8.2.3.b) BC lampholder of metal in class I luminaires shall be earthed 1.11 (8.2.3.c) Class III luminaires with exposed SELV parts: Ordinary luminaire:

17 age 17 of 48 TGM-VA EE SFT - touch current... : - no-load voltage... : Other than ordinary luminaire: - nominal voltage... : 1.11 (8.2.4) ortable luminaire: - protection independent of supporting surface - terminal block completely covered 1.11 (8.2.5) Compliance with the standard test finger or relevant probe 1.11 (8.2.6) Covers reliably secured 1.11 (8.2.7) Discharging of capacitors 0,5 µf ortable plug connected luminaire with capacitor Other plug connected luminaire with capacitor Discharge device on or within capacitor Discharge device mounted separately 1.12 (12) ENDURANCE TEST AND THERMAL TEST 1.12 (12.3) Endurance test: p - mounting-position... : Acc. To mounting instruction - test temperature ( C)... : 35 C - total duration (h)... : 240h /168h - supply voltage: Un factor; calculated voltage (V) : 1,1 Unenn 264 V, 253 V - lamp used... FD-58 - L/N G13, FD-14-L/N G5 FD-28 - L/N G5, FD-18-L/N G13 FD-18-E-G13, FD-58-E-G (12.3.2) After endurance test: - no part unserviceable - luminaire not unsafe - no damage to track system - marking legible - no cracks, deformation etc (12.4) Thermal test (normal operation) (see Annex 2) 1.12 (12.5) Thermal test (abnormal operation) (see Annex 2) 1.12 (12.6) Thermal test (failed lamp control gear condition):

18 age 18 of 48 TGM-VA EE SFT 1.12 (12.6.1) Through wiring or looping-in wiring loaded by a current of (A)... : - case of abnormal conditions... : - electronic lamp control gear - measured winding temperature ( C): at 1,1 Un. : - measured mounting surface temperature ( C) at 1,1 Un... : - calculated mounting surface temperature ( C).. : - track-mounted luminaires 1.12 (12.6.2) Temperature sensing control - case of abnormal conditions... : - thermal link - manual reset cut-out - auto reset cut-out - measured mounting surface temperature ( C)... : - track-mounted luminaires 1.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires): 1.12 (12.7.1) Luminaire without temperature sensing control 1.12 ( ) Luminaire with fluorescent lamp 70W Test method or Annex V... : Test according to : - case of abnormal conditions - Ballast failure at supply voltage (V)... : - Components retained in place after the test - Test with standard test finger after the test Test according to Annex V: - case of abnormal conditions - measured winding temperature ( C): at 1,1 Un.. : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test: - part tested; temperature ( C)... :

19 age 19 of 48 TGM-VA EE SFT 1.12 ( ) - part tested; temperature ( C)... : Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA - case of abnormal conditions - measured winding temperature ( C): at 1,1 Un.. : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : 1.12 ( ) - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : Luminaire with short circuit proof transformers 10 VA - case of abnormal conditions - Components retained in place after the test - Test with standard test finger after the test 1.12 (12.7.2) Luminaire with temperature sensing control - thermal link Yes No - manual reset cut-out Yes No - auto reset cut-out Yes No - case of abnormal conditions - highest measured temperature of fixing point/exposed part ( C):... : Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : 1.13 (9) RESISTANCE TO DUST, SOLID OBJECTS AND MOISTURE 1.13 (9.2) Tests for ingress of dust, solid objects and moisture: - classification according to I... : I 20 - mounting position during test... : Acc. to mounting instruction - fixing screws tightened; torque (Nm)... : -- - tests according to clauses... : electric strength test afterwards (see )

20 age 20 of 48 TGM-VA EE SFT a) no deposit in dust-proof luminaire b) no talcum in dust-tight luminaire c) no trace of water on current-carrying parts or where it could become a hazard d) i) For luminaires without drain holes no water entry d) ii) For luminaires with drain holes no hazardous water entry e) no water in watertight luminaire f) no contact with live parts (I 2X) f) no entry into enclosure (I 3X and I 4X) f) no contact with live parts (I3X and I4X) 1.13 (9.3) Humidity test 48 h 1.14 (10) INSULATION RESISTANCE AND ELECTRIC STRENGTH 1.14 (10.2.1) Insulation resistance test Cable or cord covered by metal foil or replaced by a metal rod of mm Ø... : Insulation resistance (MΩ) SELV: - between current-carrying parts of different polarity... : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : Other than SELV: - between live parts of different polarity... : 100 MΩ - between live parts and mounting surface... : 100 MΩ - between live parts and metal parts... : 100 MΩ - between live parts of different polarity through action of a switch... : 1.14 (10.2.2) Electric strength test Dummy lamp Luminaires with ignitors after 24 h test Luminaires with manual ignitors

21 age 21 of 48 TGM-VA EE SFT Test voltage (V): SELV: - between current-carrying parts of different polarity... : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : Other than SELV: - between live parts of different polarity... : 1480V - between live parts and mounting surface... : 1480V - between live parts and metal parts... : 1480V - between live parts of different polarity through action of a switch... : 1.14 (10.3) Touch current (ma)... : 1.15 (13) RESISTANCE TO HEAT, FIRE AND TRACKING 1.15 (13.2.1) Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : 1.15 (13.3.1) Needle flame test (10 s): - part tested... : - part tested... : 1.15 (13.3.2) Glow-wire test (650 C): - part tested... : - part tested... : 1.15 (13.4.1) Tracking test: part tested... :

22 age 22 of 48 TGM-VA EE SFT ANNEX 1: components object/part No. EMC capacitor code manufacturer/ trademark type/model technical data standard mark(s) of conformity A DNA MK µF 275V EN VDE wiring A Nexans H05V2-U, H05V2-K Screw less Terminal Screw less Terminal Screw less Terminal Starter holder Starter holder Starter holder A STUCCHI 1675/.. 450V/1,5 2,5mm² T110 C A Tridonic SLK3/ 450V/1,5 2,5mm² T110 C A BJB V/1,5 2,5mm² T85 C B BJB , , , B STUCCHI 1016A, 1017V, 1019 B STUCCHI 16A, 16/A, 16A, 16/A 0,5-2,5mm² HD 21 IMQ EN VDE EN ENEC 10 EN ENEC 10 2A 250V T100 C EN ENEC 10 2A 250V T110 C EN ENEC 03 2A 250V T110 C EN ENEC 03 Lampholder B STUCCHI G13 2A 250V T130 C EN ENEC 03 Lampholder B STUCCHI 270 S / S 13, 270/S-10 G13 2A 250V T130 C EN ENEC 03 Lampholder B STUCCHI 1274,1274/S G13 2A 250V T130 C EN ENEC 03 Lampholder B STUCCHI 272, 272/S, 1274 G13 Lamp holder B STUCCHI 1345 FAU9, /FAU9,5 Lampholder B BJB , , G13 Lampholder B BJB , , , , , , A 250V T130 C EN ENEC 03 2A 250V T130 C G13 EN ENEC 03 2A 250V T130 C EN ENEC 10 2A G5 250V T110 C EN ENEC 10 Lampholder B STUCCHI 285/MAU G5 2A 500V T110 C EN ENEC 03 Lampholder B STUCCHI 1283 G5 2A 500V T110 C EN ENEC 03 Lampholder B STUCCHI 283, 284, 285, 289 G5 2A 500V T110 C EN ENEC 03

23 age 23 of 48 TGM-VA EE SFT Lampholder B STUCCHI 268, 268N, 268F G5 Lampholder B STUCCHI 443, 442.., 441 2G11 ballast B Electrostart LSI-LL 13/230V 1x13W tw 130 AC 230V ballast B Electrostart LSI-LL 15/230V 1x15W tw 130 AC 230V ballast B Electrostart LSI-LL 2x15/230V 2A 500V T110 C EN ENEC 03 2A 250V T140 C EN ENEC 03 2x15W tw 130 AC 230V ballast B Electrostart LSI-LL 30/230V 30W tw 130 AC 230V ballast B Electrostart LSI-LL 18/230V 18W tw 130 AC 230V ballast B Electrostart LSI-LL 36/230V 1x36W tw 130 AC 230V ballast B Electrostart LSI-LL 58/230V 1x58W tw 130 AC 230V ballast B Vossloh- Schwabe ballast B Vossloh- Schwabe ballast B Vossloh- Schwabe ballast B Vossloh- Schwabe ballast B Vossloh- Schwabe ballast B Vossloh- Schwabe ELXc x14W tc 70 C V ELXc x18, 4x18W tc 70 C V ELXc x58W tc 70 C V ELXc x35W tc 70 C V ELXc x54W tc 70 C V ELXc x80W tc 70 C V EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10 ENEC 10

24 age 24 of 48 TGM-VA EE SFT ballast B Helvar EL 2x58s 2x58W tc 70 C V ballast B Helvar EL 2x28s 2x14-35S tc 70 C V ballast B Helvar EL 3/4x18S 4x18S tc 80 C V EN EN EN EN EN EN ENEC 10 ENEC 10 ENEC 10 ballast B Osram QT DL, 2x55 tc 75 C 2x55W AC V EN EN ENEC 10 ballast B Osram QT5 1x14-35 QT5 1x24-39 QT5 1x49 QT5 2x14-35 QT5 2x24-39 QT5 2x49 1x28W, 1x35W, 1x49W, 1x54W, 1x80W, 2x28W 2x35W, 2x49W AC V tc 75 C EN EN ENEC 10 ballast B Osram QTIS e 2x18 QTIS e 3x18 QTIS e 2x36 QTIS e 2x58 QTIS e 1x58 QTIS e 1x36 2x18, 3x18, 2x36, 2x58W, 1x58, 1x36 AC V tc 70 C EN EN ENEC 10 ballast B Osram Osram QT5 2x54 2x54W tc=75 C AC V EN EN ENEC 10 ballast B hilips hilips HF- 254 TL5 HO Ell tc 75 C 2x54W AC V EN EN ENEC 05 ballast B hilips hilips HF TL5 HO Ell tc 75 C 2xTL 5 14/21/28/35W AC V EN EN ENEC 05 ballast B hilips hilips HF TL5 HO Ell tc 75 C 2x14/21/28/35W AC V EN EN ENEC 05 ballast B hilips hilips HF- ¾ 14 TL5 HO Ell tc 75 C 3/4xTL5 14W, 3xTL5 21W AC V EN EN ENEC 05 ballast B hilips hilips HF-218 TLDO Ell tc 75 C 2xTL-D 18W AC V EN EN ENEC 05

25 age 25 of 48 TGM-VA EE SFT ballast B hilips hilips HF-S 258 TLD tc 75 C 2xTL-D 58W AC V EN EN ENEC 05 ballast B hilips hilips HF-S 236 TLD tc 75 C 2xTL-D 36W AC V EN EN ENEC 05 The codes above have the following meaning: A - The component is replaceable with another one, also certified, with equivalent characteristics B - The component is replaceable if authorised by the test house C - Integrated component tested together with the appliance D - Alternative component

26 age 26 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference...: S4586I20D Lamp used...: 4xFD-58-L/N-G13 Lamp control gear used...: VS ELXC Mounting position of luminaire...: Acc. To mounting instruction Supply wattage (W)...: 218,6W Supply current (A)...: 0,918A Calculated power factor...: 0.99 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode...: - test 1: rated voltage...: 240V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 254,4W temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Ballast tc point 49 C 70 C Internal wiring 46 C 90 C External wiring 41 C 90 C Screw terminal 40 C 90 C Lampholder 62 C 130 C Lampcap 71 C 120 C Mounting surface 38 C 90 C

27 age 27 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference...: S4586I20D Lamp used...: 4xFD-58-L/N-G13 Lamp control gear used...: hilips HF-S 258 TLD Mounting position of luminaire...: Acc. To mounting instruction Supply wattage (W)...: 219,9W Supply current (A)...: 0,919A Calculated power factor...: 0.99 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode...: - test 1: rated voltage...: 240V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 254,4W temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Ballast tc point 52 C 75 C Internal wiring 48 C 90 C External wiring 42 C 90 C Screw terminal 40 C 90 C Lampholder 63 C 130 C Lampcap 73 C 120 C Mounting surface 39 C 90 C

28 age 28 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference...: S4586I20D Lamp used...: 4xFD-58-L/N-G13 Lamp control gear used...: OSRAM QTIS e 2x58 Mounting position of luminaire...: Acc. To mounting instruction Supply wattage (W)...: 217,2W Supply current (A)...: 0,915A Calculated power factor...: 0.99 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode...: - test 1: rated voltage...: 240V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 254,4W temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Ballast tc point 50 C 70 C Internal wiring 47 C 90 C External wiring 42 C 90 C Screw terminal 40 C 90 C Lampholder 60 C 130 C Lampcap 72 C 120 C Mounting surface 38 C 90 C

29 age 29 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference...: TSRE2146I20DW Lamp used...: 2xFDH-14 - L/N G5 Lamp control gear used...: OSRAM QT5 2x14-35 Mounting position of luminaire...: Acc. To mounting instruction Supply wattage (W)...: 32,5W Supply current (A)...: 0,147A Calculated power factor...: 0.96 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode...: - test 1: rated voltage...: 240V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 254,4W temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Ballast tc 46 C 75 C Lamp cap 63 C 120 C Lamp holder 46 C 130 C Internal wiring 31 C 90 C External wiring/ Screw less terminal 29 C 90 C Mounting surface 28 C 90 C

30 age 30 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference...: VS4186I20VI Lamp used...: 4xFD-18- L/N -G13 Lamp control gear used...: HELVAR EL 3/4x18S Mounting position of luminaire...: Acc. to mounting instruction Supply wattage (W)...: 68,2W Supply current (A)...: 0,297A Calculated power factor...: 1,0 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode...: - test 1: rated voltage...: 240V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 254,4V temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Ballast TC point 61 C 80 C internal wiring 41 C 90 C external wiring 34 C 90 C screw terminal 34 C 90 C Lamp holder 52 C 130 C Lamp cap 72 C 120 C mounting surface 34 C 90 C

31 age 31 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference... : ES4181I20S Lamp used... : 4xFD-18-E-G13 Lamp control gear used... : Elektrostart LSI-LL 18/230 Mounting position of luminaire... : Ceiling Supply wattage (W)... : 86,1W Supply current (A)... : 0,689A Calculated power factor... : 0,54 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : Short starter circuit - test 1: rated voltage... : 230V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 244V 253V temperature ( C) of part clause normal clause 12.5 abnormal test 1 Test 2 Test 3 limits test 4 limit ballast winding 86 C 130 C 149 C 232 C internal wiring 94 C 90+5 C external wiring/ screw terminal 53 C 90 C Starter holder 42 C 130 C lamp holder 62 C 130 C lamp cap 72 C 120 C starter device 40 C 85 C 44 C 95 C mounting surface 68 C 90 C 109 C 130 C

32 age 32 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference... : ES2581I20D Lamp used... : 2x FD-58-E-G13 Lamp control gear used... : LSI-LL 58/230V Mounting position of luminaire... : Acc. to mounting instruction Supply wattage (W)... : 133,92W Supply current (A)... : 1,2A Calculated power factor... : 0,47 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : Short starter circuit - test 1: rated voltage... : 230V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 244V 253V temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Ballast winding 103 C 130 C 193 C 232 C internal wiring 80 C 90 C external wiring/ screw terminal 46 C 90 C Lamp holder 79 C 130 C Lamp cap 114 C 120 C Starter holder 41 C 120 C Starter device 42 C 85 C mounting surface 72 C 90 C 113 C 130 C

33 age 33 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference...: TSRE4146I20DW Lamp used...: 4xFDH-14 - L/N G5 Lamp control gear used...: hilips HF- ¾ 14 TL5 HO Ell Mounting position of luminaire...: Acc. To mounting instruction Supply wattage (W)...: 64,2W Supply current (A)...: 0,281A Calculated power factor...: 0.98 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode...: - test 1: rated voltage...: 240V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : 254,4W temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Ballast tc 49 C 75 C Lamp cap 61 C 120 C Lamp holder 45 C 130 C Internal wiring 32 C 90 C External wiring/ Screw less terminal 30 C 90 C Mounting surface 28 C 90 C

34 age 34 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference... : TSRE 2286I20DW Lamp used... : 2xFDH-28-L/N-G5 Lamp control gear used... : QT-5 2x14-35 Quicktronic rofesional Mounting position of luminaire... : Acc. to mounting instruction Supply wattage (W)... : 53,4W Supply current (A)... : 0,236A Calculated power factor... : 0,98 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : - test 1: rated voltage... : 230V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : 244V temperature ( C) of part clause normal clause 12.5 abnormal test 1 Test 2 Test 3 limits test 4 limit ballast tc 59 C 75 C internal wiring 50 C 90 C lamp cap 63 C 120 C lamp holder 51 C 130 C mounting surface 34 C 90 C External wiring/ Screw less terminal 31 C 90 C

35 age 35 of 48 TGM-VA EE SFT ANNEX 2: temperature measurements, thermal tests of Section 12 Type reference... : S 2586I20D Lamp used... : 2xFDH-58-L/N-G13 Lamp control gear used... : Helvar EL 2x58s Mounting position of luminaire... : Acc. to mounting instruction Supply wattage (W)... : 53,4W Supply current (A)... : 0,236A Calculated power factor... : 0,98 Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : - test 1: rated voltage... : 230V - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : 244V temperature ( C) of part clause normal clause 12.5 abnormal test 1 Test 2 Test 3 limits test 4 limit ballast tc 58 C 70 C internal wiring 51 C 90 C lamp cap 67 C 120 C lamp holder 54 C 130 C mounting surface 35 C 90 C External wiring/ Screw less terminal 30 C 90 C

36 age 36 of 48 TGM-VA EE SFT ANNEX 3: screw terminals (part of the luminaire) (14) SCREW TERMINALS (14.2) Type of terminal... : Rated current (A)... : ( ) One or more conductors ( ) Special preparation ( ) Terminal size Cross-sectional area (mm²)... : (14.3.3) Conductor space (mm)... : (14.4) Mechanical tests (14.4.1) Minimum distance (14.4.2) Cannot slip out (14.4.3) Special preparation (14.4.4) Nominal diameter of thread (metric ISO thread). : M4 External wiring No soft metal (14.4.5) Corrosion (14.4.6) Nominal diameter of thread (mm)... : Torque (Nm)... : (14.4.7) Between metal surfaces Lug terminal Mantle terminal ull test; pull (N)... : (14.4.8) Without undue damage

37 age 37 of 48 TGM-VA EE SFT ANNEX 4: screwless terminals (part of the luminaire) (15) SCREWLESS TERMINALS (15.2) Type of terminal... : Rated current (A)... : (15.3.1) Material (15.3.2) Clamping (15.3.3) Stop (15.3.4) Unprepared conductors (15.3.5) ressure on insulating material (15.3.6) Clear connection method (15.3.7) Clamping independently (15.3.8) Fixed in position ( ) Conductor size Type of conductor (15.5.1) Terminals internal wiring ( ) ull test spring-type terminals (4 N, 4 samples).: ( ) ull test pin or tab terminals (4 N, 4 samples) : Insertion force not exceeding 50 N (15.5.2) ermanent connections: pull-off test (20 N) (15.6) Electrical tests Voltage drop (mv) after 1 h (4 samples)... : Voltage drop of two inseparable joints Number of cycles... : Voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : Voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : After ageing, voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : After ageing, voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : (15.7) Terminals external wiring

38 age 38 of 48 TGM-VA EE SFT Terminal size and rating (15.8.1) ull test spring-type terminals or welded connections (4 samples); pull (N)... : ull test pin or tab terminals (4 samples); pull (N)... : (15.9) Contact resistance test Voltage drop (mv) after 1 h terminal voltage drop (mv) Voltage drop of two inseparable joints Voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv)

39 age 39 of 48 TGM-VA EE SFT ATTACHMENT TO TEST REORT EUROEAN GROU DIFFERENCES AND NATIONAL DIFFERENCES Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Differences according... : EN :1989 used in conjunction with EN : A11:2009 Annex Form No.... : EU_GD_IEC_60598_2_1B Annex Form Originator... : IMQ S.p.A. Master Annex Form... : Copyright 2009 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. CENELEC COMMON MODIFICATIONS (EN) 1.5 (3) MARKING 1.5 ( ) Adequate warning on the package 1.6 (4) CONSTRUCTION 1.6 (4.11.6) Electro-mechanical contact systems 1.10 (5) EXTERNAL AND INTERNAL WIRING 1.10 (5.2.1) Connecting leads - without a means for connection to the supply - terminal block specified - relevant information provided - compliance with 4.6, 4.7.1, 4.7.2, , 11.2, 12 and 13.2 of art (5.2.2) Cables equal to HD21 S2 or HD22 S (12) ENDURANCE TEST AND THERMAL TEST 1.12 (12.4.2c) Thermal test (normal operation)

40 age 40 of 48 TGM-VA EE SFT ZB ANNEX ZB, SECIAL NATIONAL CONDITIONS (EN) (3.3) DK: power supply cord with label IT: warning label on Class 0 luminaire (4.5.1) DK: socket-outlets (5.2.1) CY, DK, FI, SE, GB: type of plug ZC ANNEX ZC, NATIONAL DEVIATIONS (EN) (4 & 5) FR: Shuttered socket-outlets 10/16A (13.3) (13.3) FR: Glow-wire test 850 C alt. 750 C for luminaires in premises open to public or 960 C for luminaires in emergency exits GB: Requirements according to United Kingdom Building Regulation

41 age 41 of 48 TGM-VA EE SFT Trade mark Type code with Magnetic ballast Type E Degree of protection Type of protection Wattage and lamp holder MARELI. LTD ES1181I20S I20 Cl.I 1xFD-18-E-G13 MARELI. LTD ES1361I20S I20 Cl.I 1xFD-36-E-G13 MARELI. LTD ES1581I20S I20 Cl.I 1xFD-58-E-G13 MARELI. LTD ES2181I20S I20 Cl.I 2xFD-18-E-G13 MARELI. LTD ES2361I20S I20 Cl.I 2xFD-36-E-G13 MARELI. LTD ES2581I20S I20 Cl.I 2xFD-58-E-G13 MARELI. LTD ES3181I20S I20 Cl.I 3xFD-18-E-G13 MARELI. LTD ES3361I20S I20 Cl.I 3xFD-36-E-G13 MARELI. LTD ES3581I20S I20 Cl.I 3xFD-58-E-G13 MARELI. LTD ES4181I20S I20 Cl.I 4xFD-18-E-G13 MARELI. LTD ES4361I20S I20 Cl.I 4xFD-36-E-G13 MARELI. LTD ES4581I20S I20 Cl.I 4xFD-58-E-G13 MARELI. LTD ES1181I20D I20 Cl.I 1xFD-18-E-G13 MARELI. LTD ES1361I20D I20 Cl.I 1xFD-36-E-G13 MARELI. LTD ES1581I20D I20 Cl.I 1xFD-58-E-G13 MARELI. LTD ES2181I20D I20 Cl.I 2xFD-18-E-G13 MARELI. LTD ES2361I20D I20 Cl.I 2xFD-36-E-G13 MARELI. LTD ES2581I20D I20 Cl.I 2xFD-58-E-G13 MARELI. LTD ES3181I20D I20 Cl.I 3xFD-18-E-G13 MARELI. LTD ES3361I20D I20 Cl.I 3xFD-36-E-G13 MARELI. LTD ES3581I20D I20 Cl.I 3xFD-58-E-G13 MARELI. LTD ES4181I20D I20 Cl.I 4xFD-18-E-G13 MARELI. LTD ES4361I20D I20 Cl.I 4xFD-36-E-G13 MARELI. LTD ES4581I20D I20 Cl.I 4xFD-58-E-G13 Trade mark Type VENY Degree of protection Type of protection Wattage and lamp holder MARELI. LTD VS2181I20VW I20 Cl.I 2xFD-18-E-G13 MARELI. LTD VS2361I20VW I20 Cl.I 2xFD-36-E-G13 MARELI. LTD VS3181I20VW I20 Cl.I 3xFD-18-E-G13 MARELI. LTD VS3361I20VW I20 Cl.I 3xFD-36-E-G13

42 age 42 of 48 TGM-VA EE SFT MARELI. LTD VS4181I20VW I20 Cl.I 4xFD-18-E-G13 MARELI. LTD VS4361I20VW I20 Cl.I 4xFD-36-E-G13 MARELI. LTD VS2181I20VI I20 Cl.I 2xFD-18-E-G13 MARELI. LTD VS2361I20VI I20 Cl.I 2xFD-36-E-G13 MARELI. LTD VS3181I20VI I20 Cl.I 3xFD-18-E-G13 MARELI. LTD VS3361I20VI I20 Cl.I 3xFD-36-E-G13 MARELI. LTD VS4181I20VI I20 Cl.I 4xFD-18-E-G13 MARELI. LTD VS4361I20VI I20 Cl.I 4xFD-36-E-G13 Degree of Type of Trade mark Type RO Wattage and lamp holder protection protection MARELI. LTD S1181I20S I20 Cl.I 1xFD-18-E-G13 MARELI. LTD S1361I20S I20 Cl.I 1xFD-36-E-G13 MARELI. LTD S1581I20S I20 Cl.I 1xFD-58-E-G13 MARELI. LTD S2181I20S I20 Cl.I 2xFD-18-E-G13 MARELI. LTD S2361I20S I20 Cl.I 2xFD-36-E-G13 MARELI. LTD S2581I20S I20 Cl.I 2xFD-58-E-G13 MARELI. LTD S3181I20S I20 Cl.I 3xFD-18-E-G13 MARELI. LTD S3361I20S I20 Cl.I 3xFD-36-E-G13 MARELI. LTD S3581I20S I20 Cl.I 3xFD-58-E-G13 MARELI. LTD S4181I20S I20 Cl.I 4xFD-18-E-G13 MARELI. LTD S4361I20S I20 Cl.I 4xFD-36-E-G13 MARELI. LTD S4581I20S I20 Cl.I 4xFD-58-E-G13 MARELI. LTD S1181I20D I20 Cl.I 1xFD-18-E-G13 MARELI. LTD S1361I20D I20 Cl.I 1xFD-36-E-G13 MARELI. LTD S1581I20D I20 Cl.I 1xFD-58-E-G13 MARELI. LTD S2181I20D I20 Cl.I 2xFD-18-E-G13 MARELI. LTD S2361I20D I20 Cl.I 2xFD-36-E-G13 MARELI. LTD S2581I20D I20 Cl.I 2xFD-58-E-G13 MARELI. LTD S3181I20D I20 Cl.I 3xFD-18-E-G13 MARELI. LTD S3361I20D I20 Cl.I 3xFD-36-E-G13 MARELI. LTD S3581I20D I20 Cl.I 3xFD-58-E-G13 MARELI. LTD S4181I20D I20 Cl.I 4xFD-18-E-G13

43 age 43 of 48 TGM-VA EE SFT MARELI. LTD S4361I20D I20 Cl.I 4xFD-36-E-G13 MARELI. LTD S4581I20D I20 Cl.I 4xFD-58-E-G13 Trade mark Type code with Electronic ballast Type T Degree of protection Type of protection Wattage and lamp holder MARELI. LTD TSRE2146I20DW I20 Cl.I 2xFD-14-L/N G5 MARELI. LTD TSRE2286I20DW I20 Cl.I 2xFD-28-L/N G5 MARELI. LTD TSRE2546I20DW I20 Cl.I 2xFD-54-L/N G5 MARELI. LTD TSRE2356I20DW I20 Cl.I 2xFD-35-L/N G5 MARELI. LTD TSRE2496I20DW I20 Cl.I 2xFD-49-L/N G5 MARELI. LTD TSRE2806I20DW I20 Cl.I 2xFD-80-L/N G5 MARELI. LTD TSRE3146I20DW I20 Cl.I 3xFD-14-L/N G5 MARELI. LTD TSRE4146I20DW I20 Cl.I 4xFD-14-L/N G5 Trade mark Type VENY Degree of protection Type of protection Wattage and lamp holder MARELI. LTD VS2186I20VW I20 Cl.I 2xFD-18-L/N G13 MARELI. LTD VS2366I20VW I20 Cl.I 2xFD-36-L/N G13 MARELI. LTD VS2146I20VW I20 Cl.I 2xFD-14-L/N G5 MARELI. LTD VS2286I20VW I20 Cl.I 2xFD-28-L/N G5 MARELI. LTD VS2546I20VW I20 Cl.I 2xFD-54-L/N G5 MARELI. LTD VS3186I20VW I20 Cl.I 3xFD-18-L/N G13 MARELI. LTD VS3366I20VW I20 Cl.I 3xFD-36-L/N G13 MARELI. LTD VS3146I20VW I20 Cl.I 3xFD-14-L/N G5 MARELI. LTD VS4186I20VW I20 Cl.I 4xFD-18-L/N G13 MARELI. LTD VS4366I20VW I20 Cl.I 4xFD-36-L/N G13 MARELI. LTD VS4146I20VW I20 Cl.I 4xFD-14-L/N G5 MARELI. LTD VS2186I20VI I20 Cl.I 2xFD-18-L/N G5 MARELI. LTD VS2366I20VI I20 Cl.I 2xFD-36-L/N G13 MARELI. LTD VS2146I20VI I20 Cl.I 2xFD-14-L/N G5 MARELI. LTD VS2286I20VI I20 Cl.I 2xFD-28-L/N G5 MARELI. LTD VS2546I20VI I20 Cl.I 2xFD-54-L/N G5 MARELI. LTD VS3186I20VI I20 Cl.I 3xFD-18-L/N G13 MARELI. LTD VS3366I20VI I20 Cl.I 3xFD-36-L/N G13

44 age 44 of 48 TGM-VA EE SFT MARELI. LTD VS3146I20VI I20 Cl.I 3xFD-14-L/N G5 MARELI. LTD VS4186I20VI I20 Cl.I 4xFD-18-L/N G13 MARELI. LTD VS4366I20VI I20 Cl.I 4xFD-36-L/N G13 MARELI. LTD VS4146I20VI I20 Cl.I 4xFD-14-L/N G5 Trade mark Type E Degree of protection Type of protection Wattage and lamp holder MARELI. LTD ES1186I20S I20 Cl.I 1xFD-18-L/N G13 MARELI. LTD ES1366I20S I20 Cl.I 1xFD-36-L/N G13 MARELI. LTD ES1586I20S I20 Cl.I 1xFD-58-L/N G13 MARELI. LTD ES2186I20S I20 Cl.I 2xFD-18-L/N G13 MARELI. LTD ES2366I20S I20 Cl.I 2xFD-36-L/N G13 MARELI. LTD ES2586I20S I20 Cl.I 2xFD-58-L/N G13 MARELI. LTD ES3186I20S I20 Cl.I 3xFD-18-L/N G13 MARELI. LTD ES3366I20S I20 Cl.I 3xFD-36-L/N G13 MARELI. LTD ES3586I20S I20 Cl.I 3xFD-58-L/N G13 MARELI. LTD ES4186I20S I20 Cl.I 4xFD-18-L/N G13 MARELI. LTD ES4366I20S I20 Cl.I 4xFD-36-L/N G13 MARELI. LTD ES4586I20S I20 Cl.I 4xFD-58-L/N G13 MARELI. LTD ES1186I20D I20 Cl.I 1xFD-18-L/N G13 MARELI. LTD ES1366I20D I20 Cl.I 1xFD-36-L/N G13 MARELI. LTD ES1586I20D I20 Cl.I 1xFD-58-L/N G13 MARELI. LTD ES2186I20D I20 Cl.I 2xFD-18-L/N G13 MARELI. LTD ES2366I20D I20 Cl.I 2xFD-36-L/N G13 MARELI. LTD ES2586I20D I20 Cl.I 2xFD-58-L/N G13 MARELI. LTD ES3186I20D I20 Cl.I 3xFD-18-L/N G13 MARELI. LTD ES3366I20D I20 Cl.I 3xFD-36-L/N G13 MARELI. LTD ES3586I20D I20 Cl.I 3xFD-58-L/N G13 MARELI. LTD ES4186I20D I20 Cl.I 4xFD-18-L/N G13 MARELI. LTD ES4366I20D I20 Cl.I 4xFD-36-L/N G13 MARELI. LTD ES4586I20D I20 Cl.I 4xFD-58-L/N G13 Trade mark Type RO Degree of protection Type of protection Wattage and lamp holder MARELI. LTD S1186I20S I20 Cl.I 1xFD-18-L/N G13

45 age 45 of 48 TGM-VA EE SFT MARELI. LTD S1366I20S I20 Cl.I 1xFD-36-L/N G13 MARELI. LTD S1586I20S I20 Cl.I 1xFD-58-L/N G13 MARELI. LTD S2186I20S I20 Cl.I 2xFD-18-L/N G13 MARELI. LTD S2366I20S I20 Cl.I 2xFD-36-L/N G13 MARELI. LTD S2586I20S I20 Cl.I 2xFD-58-L/N G13 MARELI. LTD S3186I20S I20 Cl.I 3xFD-18-L/N G13 MARELI. LTD S3366I20S I20 Cl.I 3xFD-36-L/N G13 MARELI. LTD S3586I20S I20 Cl.I 3xFD-58-L/N G13 MARELI. LTD S4186I20S I20 Cl.I 4xFD-18-L/N G13 MARELI. LTD S4366I20S I20 Cl.I 4xFD-36-L/N G13 MARELI. LTD S4586I20S I20 Cl.I 4xFD-58-L/N G135 MARELI. LTD S1186I20D I20 Cl.I 1xFD-18-L/N G13 MARELI. LTD S1366I20D I20 Cl.I 1xFD-36-L/N G13 MARELI. LTD S1586I20D I20 Cl.I 1xFD-58-L/N G13 MARELI. LTD S2186I20D I20 Cl.I 2xFD-18-L/N G13 MARELI. LTD S2366I20D I20 Cl.I 2xFD-36-L/N G13 MARELI. LTD S2586I20D I20 Cl.I 2xFD-58-L/N G13 MARELI. LTD S3186I20D I20 Cl.I 2xFD-18-L/N G13 MARELI. LTD S3366I20D I20 Cl.I 2xFD-36-L/N G13 MARELI. LTD S3586I20D I20 Cl.I 2xFD-58-L/N G13 MARELI. LTD S4186I20D I20 Cl.I 4xFD-18-L/N G13 MARELI. LTD S4366I20D I20 Cl.I 4xFD-36-L/N G13 MARELI. LTD S4586I20D I20 Cl.I 4xFD-58-L/N G13

46 age 46 of 48 TGM-VA EE SFT TSRE I20 DW

47 age 47 of 48 TGM-VA EE SFT TSRE I20DW

48 age 48 of 48 TGM-VA EE SFT VS I20S

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements Section 1: Fixed general purpose luminaires Report Number.... : 64.140.11.02922.03 Date of issue... : 2015-02-02 Total number of pages...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date

More information

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Number.... : 17041854 001 Date of

More information

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct

More information

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT) Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB13035196 Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR

More information

Page 1 of 27 Report No. : HT15DR LVD Test Report

Page 1 of 27 Report No. : HT15DR LVD Test Report age 1 of 27 LVD Test Report EN60598-1&EN60598-2-1 art 1:General requirement and tests art 2: articular requirments Section One Fixed general purpose luminaires Report reference No.......: HT15DR-120321

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REORT Luminaires art 2.1: articular requirements Fixed general purpose luminaires Accredited for compliance with ISO/IEC 17025 Report Reference No.... : S17031 Compiled by (+ signature)... : Yongchan

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires age 1 of 40 TEST REORT IEC 60598-2-2 Luminaires art 2: articular requirements Section 2: Recessed luminaires Report Number.... : 7040216100405-00 Date of issue... : 2016-11-18 Total number of pages...

More information

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights TEST REORT EN 60598-2-21 Luminaires art 2: articular requirements Section 21: Rope Lights Report reference No.... : ED170727001S Tested by... : Coral Chen Approved by... : Kobe Mai Date of issue... : August

More information

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires TEST REORT EN 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No...: 3007562.50-QUA/LI Date of issue...: 2011-03-28 Total number of pages...

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Test Report issued under the responsibility of: Studio Oleandri - Milano TEST REPORT IEC 60598-2-1 Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Report Number...

More information

EN : MEASUREMENT AND TEST REPORT For

EN : MEASUREMENT AND TEST REPORT For E 60598-1: 2004 MEASUREMET AD TEST REORT For LOGSTAR LIGHTIG GROU TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, China Model:LS-T8-T600S1,LS-T8-T900S1,LS-T8-T1200S1,LS-T8-T1500S1,LS-T8-M600S1,

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 1540-44-I Date of issue... : 2016-09-01

More information

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires TEST REORT Luminaires art 1: General requirements and Tests art 2: articular requirements - Section 4: ortable general purpose luminaires Report Reference o: Tested by: T1321-21-12 Urs Wyttenbach Approved

More information

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598.

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598. Doc Id: AS/ZS60598.2.1:2014+A1 Report o: 0803BSS-61900_59821 age 1 of 49 Compliance Testing Report for Australian/ew Zealand Standard AS/ZS 60598.2.1: 2014 Inc Amendment 1 in conjunction with AS/ZS60598.1:2013

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT IEC LED modules for general lighting Safety specifications Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CGZ3150109-00114-L-F GZ test site: A101, o.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China Summary of testing: Tests performed (name of test and test clause): The submitted samples were found to comply with the requirements of: -- E 60598-2-2:2012 -- E 60598-1:2008+A11:2009 Testing location:

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 6011995.50 Date of issue... :

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):

More information

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting TEST REORT AS/ZS 60598.2.3:2015 Luminaires art 2.3: articular requirements Luminaires for road and street lighting Report Reference o.... : RSZ170419551-03 Compiled by (+ signature)... : Andy Fu Approved

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China,

Shenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China, Shenzhen BST Technology Co., Ltd Shenzhen Merrylux Optoelectronics co., ltd TEST REORT repared For: Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan,

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,

More information

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing

More information

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment):

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment): age 3 of 90 Report No.: 17052930 001 List of Attachments (including a total number of pages in each attachment): Attachment 1: 12 pages of photos. Summary of testing: Tests performed (name of test and

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED age 1 of 47 Report o. R011501451I SAA TEST REORT On Behalf of AOK LED LIGHT COMAY LIMITED LED Street Light Model: AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL,

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...

More information

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REPORT Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Report Reference No...: HZ10120073-001 ate of issue...:

More information

Page 3 of 32 Report No Summary of testing:

Page 3 of 32 Report No Summary of testing: age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016

More information

Test report: 13/ Date January 20 th,2014 Page 1 of 52

Test report: 13/ Date January 20 th,2014 Page 1 of 52 LGAI LGAI Technological Center, S.A. Campus de la UAB Apartado de Correos 18 E - 08193 Bellaterra (Barcelona) T +34 93 567 20 00 F +34 93 520 20 01 www.appluslaboratories.com TEST REORT Test report: 13/31705080

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires Report Reference o....: Compiled by (+ signature)...: Approved by (+ signature)... : TEST REORT AS/ZS 60598.2.1 Luminaires art 2: articular requirements: Fixed general purpose luminaires RSZ160822550-03

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007 Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are

More information

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches

TEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches Test Report issued under the responsibility of: TEST REPORT Switches for appliances Part 2-1: Particular requirements for cord switches Report Reference No.... : SH11080876-001 Date of issue... : 2012-02-23

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of TEST REORT IEC 60884-1 lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 2228900-1520-0001/175202

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

Test Report issued under the responsibility of: Report Number...:

Test Report issued under the responsibility of: Report Number...: Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

to use the European Mark Licence No Date of issue: Wien, Rev. No. 02 Wien,

to use the European Mark Licence No Date of issue: Wien, Rev. No. 02 Wien, AUSTRIAN ELECTROTECHNICAL ASSOCIATION 1010 Wien, Eschenbachgasse 9 ZVR: 327279890 VR: 1055887 Testing & Certification Kahlenberger Str. 2A 1190 Wien, Phone: +43 1 370 58 06 Fax: +43 1 370 58 06-199 LICENCE

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 70.410.14.127.01-01 Date of issue... : 2014-07-03 Total number of pages... 61

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294

More information

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires Test Report issued under the responsibility of: TEST REORT E 60598-2-2: 1996 LUMIAIRES --- SAFETY--- ART 2-2: articular requirements- Recessed luminaires Report reference o...: GTSS12080044101 Compiled

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050805SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan Road,

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT. IEC 62133: 2012 (Second Edition) Test Report issued under the responsibility of: TEST REORT, Second Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TUBE. Precise construction encourages reliable IP rating. Bi-directional light output with single light source. Choices of light distribution angles.

TUBE. Precise construction encourages reliable IP rating. Bi-directional light output with single light source. Choices of light distribution angles. TUBE TUBE TUBE family is available in 4 different sizes. They are protected from the ingress of dust and water and are used in both outdoor and indoor environments. Operating with PAR, Compact Fluorescent,

More information

Test Report No EEC12-02/MLM dated 29 MAR 2012

Test Report No EEC12-02/MLM dated 29 MAR 2012 Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group and the General Terms and Conditions of Business of TÜV SÜD SB te Ltd. In addition, this report is

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date

More information

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REPORT AS/NZS 60598.2.2:2001 Luminaires Part 2: Particular requirements Recessed luminaires Report Reference No....: S08007 Approved by (+ signature)...: I Absolom Date of issue...: Thursday, 31 January

More information

SHA-001 Date of issue...: Total number of pages Report Reference No...:

SHA-001 Date of issue...: Total number of pages Report Reference No...: TEST REORT lugs and socket-outlets for household and similar purposes art 2-1: General requirements on plugs and portable socket-outlets Report Reference No....: 130600884SHA-001 Date of issue...: 2013-07-09

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools art 2: articular requirements for drills and impact drills Report reference No.... : 3130837.50A

More information

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances - age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information