1 Shenzhen BST Technology Co., Ltd Shenzhen Merrylux Optoelectronics co., ltd TEST REORT repared For: Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan, Shenzhen, China, roduct ame: LED Flood light Model : 200W, 150W, 120W, 100W, 70W, 50W, 30W, 20W, 10W repared By : Building o.23-24, Zhiheng industrial park, Guankouer Road, antou, anshan District, Shenzhen, Guangdong, China Test Date: Apr. 19, 2015 Apr. 30, 2015 Date of Report : Apr. 30, 2015 Report o.: BST SR-2 age 1 of 44

2 2 Report o.: BST SR- TEST REORT AS/ZS & IEC :1998 Luminaires art 1: General requirements and tests art 2: articular requirements Section Five Floodlights Testing Laboratory ame...: Address... : Testing location...: Applicant's ame...: Address... : Manufacturer : Address : Test specification Standard...: rocedure deviation... : on-standard test method...: Test item description... : Trademark...: Building o.23-24, Zhiheng industrial park, Guankouer Road, antou, anshan District, Shenzhen, Guangdong, China Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan, Shenzhen, China, Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan, Shenzhen, China, IEC :1998 used in conjunction with AS/ZS :2013 SAA /A LED Flood light Merrylux Model and/or type reference...: See page 1 Rating(s)...: V~, 50/60Hz, 200W, F>0.9, I65 Test case verdicts Test case does not apply to the test object... : Test item does meet the requirement...: Test item does not meet the requirement... : /A (ass) F(ail) age 2 of 44

3 General remarks This report shall not be reproduced except in full without the written approval of the testing laboratory. The test results presented in this report relate only to the item(s) tested. (see remark #)" refers to a remark appended to the report. "(see Annex #)" refers to an annex appended to the report. Clause numbers between brackets refer to clauses in IEC (AS/ZS ) Throughout this report a comma is used as the decimal separator. Copy of marking plate: (Take model 200W for example) Merrylux LED Flood light Model: 200W Input: V~, 50/60Hz, 200W, F>0.9 I65 Ta:40 Approved o.: XXXXXX Shenzhen Merrylux Optoelectronics co., ltd Made In China age 3 of 44

4 Summary of construction and testing These series products are LED Flood light supplied by the identical series ballast, they have the similar construction, the differences among them are appearance size, weight and wattage based on LED lamp. All tests were conducted at the model 200W having max watts. The test results comply with the requirement of the relevant standards. Differences of series models: age 4 of 44

5 ame and address of the testing laboratory : Shenzhen BST Technology Co.,Ltd. Building o.23-24, Zhiheng industrial park, Guankouer Road, antou, anshan District, Shenzhen, Guangdong, China Test by : Signature Apr. 19, 2015 Apr. 30, 2015 Date Technician Title Review by : Signature Apr. 30, 2015 Date roject Engineer Title Approved by : Signature Apr. 30, 2015 Date Christina/ Manager ame and Title age 5 of 44

6 AS/ZS & IEC Cl. Requirement Test Result Verdict 5.1 (0) SCOE 5.1 (0.1) More sections applicable... : Yes [ ] o [ ] 5.4 (2) CLASSIFICATIO 5.4 (2.2) Type of protection... : Class I 5.4 (2.3) Degree of protection...: I (2.4) ortable or handheld luminaire...: o Fixed luminaire suitable for normally flammable Yes surfaces...: Fixed luminaire suitable for non-combustible o materials only... : 5.4 (2.5) Luminaire for normal use...: Yes Luminaire for rough service...: o 5.5 (3) MARKIG 5.5 (3.2) Mandatory markings osition of the marking On the enclosure Format of symbols/text Symbols: 5.0mm min; Letter: 2.0mm min. 5.5 (3.3) Additional information Language of instructions English 5.5 (3.3.1) Combination luminaires 5.5 (3.3.2) ominal frequency in Hz 50/60Hz 5.5 (3.3.3) Operating temperature See marking plate 5.5 (3.3.4) Symbol or warning notice 5.5 (3.3.5) Wiring diagram 5.5 (3.3.6) Special conditions 5.5 (3.3.7) Metal halid lamp luminaire warning 5.5 (3.3.8) Limitation for semi-luminaires 5.5 (3.3.9) ower factor and supply current 5.5 (3.3.10) 5.5 (3.3.11) Suitability for outdoors or indoor Luminaires with remote control Suitability for use "outdoors" 40 C age 6 of 44

7 5.5 (3.3.12) 5.5 (3.3.13) 5.5 (3.3.14) 5.5 (3.3.15) 5.5 (3.3.16) 5.5 (3.3.17) 5.5 (3.3.18) 5.5 (3.3.19) Clip-mounted luminaire warning Specifications of protective shields Symbol for nature of supply ~ Rated current of socket outlet o socket outlet Rough service luminaire Mounting instruction for type Y, type Z and some type X attachments on-ordinary luminaires with VC cable The protective conductor current shall be clearly stated in the manufacturers instructions Type Y 5.5 (3.4) Test with water 15s with water Test with hexane 15s with hexane Legible after test Yes Label attached The marking not be easily removable and shows no curling 5.5 Where necessary, to ensure proper use and maintenance, the following additional particulars shall also be marked on the floodlight or otherwise made available to the purchaser Operating position, if not universal Weight and overall dimensions of the floodlight Maximum projected area of the floodlight Range of mounting heights Suitability for use indoors 5.6 (4) COSTRUCTIO (- ) At least IX3 I (- ) Lampholder brackets (- ) Adjusting means (- ) Controlling components (- ) Fixing device 0.9 K Wind force test (- ) Locking system (- ) Vibration resistance age 7 of 44

8 5.6.8 (-) Glass cover 5.6 (4.2) Components replaceable without difficulty 5.6 (4.3) Wireways smooth and free from sharp edges 5.6 (4.4) Lampholders 5.6 (4.4.1) Integral lampholder 5.6 (4.4.2) Wiring connection 5.6 (4.4.3) Lampholder for end to end mounting 5.6 (4.4.4) ositioning 5.6 (4.4.5) eak pulse voltage 5.6 (4.4.6) Centre contact 5.6 (4.4.7) Rough service luminaires 5.6 (4.4.8) Lamp connectors o lamp connector provided 5.6 (4.5) Starter holders Starter holder in luminaires other than class II Starter holder class II construction 5.6 (4.6) Terminal blocks Tails Unsecured blocks 5.6 (4.7) Terminals and supply connections 5.6 (4.7.1) Contact to metal parts 5.6 (4.7.2) Test 8 mm live conductor Test 8 mm earth conductor 5.6 (4.7.3) Terminals for supply conductors 5.6 (4.7.4) Terminals other than supply connection 5.6 (4.7.5) Heat-resistant wiring/sleeves 5.6 (4.7.6) Multi-pole plug o multi-pole plug 5.6 (4.8) Switches: -- - adequate rating o switch - adequate fixing - polarized supply 5.6 (4.9) Insulating lining and sleeves 5.6 (4.9.1) Retainment Method of fixing... : 5.6 (4.9.2) Insulated linings and sleeves a) & c) Insulation resistance and electric strength b) Ageing test. Temperature ( C)... : 5.6 (4.10) Insulation of Class II luminaires -- age 8 of 44

9 5.6 (4.10.1) o contact, mounting surface - accessible metal parts - wiring of basic insulation Safe installation fixed luminaires Capacitors Interference suppression capacitors according to IEC Assembly gaps: -- (4.10.2) not coincidental no straight access with test probe 5.6 Retainment of insulation: (4.10.3) fixed unable to be replaced; luminaire inoperative sleeves retained in position lining in lampholder 5.6 (4.11) Electrical connections 5.6 Contact pressure (4.11.1) 5.6 Screws: (4.11.2) self-tapping screws thread cutting screws 4.5mm: 2.0m at least two self-tapping screws 5.6 Screw locking: -- (4.11.3) spring washer rivets 5.6 (4.11.4) Material of current-carrying parts 5.6 (4.11.5) 5.6 (4.11.6) o contact to wood o wood material in the luminaire Electro-mechanical contact systems o such systems 5.6 (4.12) Mechanical connections and glands 5.6 Screws not made of soft metal (4.12.1) Screws of insulating material Torque test: torque (m); part... : 4.5mm: 2.0m Torque test: torque (m); part... : age 9 of 44

10 5.6 Screws with diameter < 3 mm screwed into metal (4.12.2) 5.6 Locked connections: -- (4.12.4) - fixed arms; torque (m)...: - lampholder; torque (m)... : - push-button switches; torque 0,8 m...: 5.6 Screwed glands; force ()...: 25 (4.12.5) 5.6 (4.13) Mechanical strength Impact tests: (4.13.1) fragile parts; energy (m)...: Glass cover: 0.35m other parts; energy (m)... : Enclosure : 0.7m 1) live parts ot accessed 2) linings ot impaired 3) protection Continue to afford the degree of protection against ingress of dust, solid objects and moisture 4) covers o break 5.6 Straight test finger 30 (4.13.3) 5.6 Rough service luminaires (4.13.4) a) fixed b) hand-held c) delivered with a stand d) for temporary installations and suitable for mounting on a stand 5.6 Tumbling barrel (4.13.6) 5.6 (4.14) Suspensions and adjusting devices 5.6 Mechanical load: (4.14.1) A) four times the weight 4*11.5kg (for model:200w) B) torque 2,5 m >2,5 m C) bracket arm; bending moment (m)...: 3.0m D) load track mounted luminaires E) clip-mounted luminaires, glass-shelve. Thickness (mm)...: age 10 of 44

11 5.6 (4.14.2) 5.6 (4.14.3) 5.6 (4.14.4) 5.6 (4.14.5) 5.6 (4.14.6) metal rod. Diameter (mm)... : Load to flexible cables Mass (kg)...: Stress in conductors (/mm²)... : Semi-luminaires mass (kg)... : Semi-luminaires bending moment (m)... : Adjusting devices: flexing test; number of cycles... : 1500cycles strands broken electric strength test afterwards Telescopic tubes: cords not fixed to tube; no strain on conductors o telescopic tubes Guide pulleys o guide pulleys Strain on socket-outlets o socket-outlet 1.6 (4.15) Flammable materials: glow wire test 650 C spacing 30 mm screen withstanding test of screen dimensions no fiercely burning material thermal protection electronic circuits exempted 5.6 Luminaires made of thermoplastic material with lamp control gear (4.15.2) a) construction b) temperature sensing control c) surface temperature 5.6 (4.16) Luminaires marked with F-symbol o lamp control gear Approved 5.6 Lamp control gear spacing: (4.16.1) spacing 35 mm spacing 10 mm 5.6 (4.16.2) Thermal protection: -- age 11 of 44

12 - in lamp control gear - external - fixed position - temperature marked lamp control gear 5.6 "F" curve measured (see 12.6) (4.16.3) 5.6 (4.17) Drain holes o drain holes Clearance at least 5 mm 1.6 (4.18) Resistance to corrosion: rust resistance (4.18.1) season cracking in copper (4.18.2) corrosion of aluminium (4.18.3) 5.6 (4.19) Ignitors compatible with ballast 5.6 (4.20) Rough service vibration... : 5.6 (4.21) rotective shield: 5.6 Shield fitted (4.21.1) 5.6 articles from a shattering lamp not impair safety (4.21.2) 5.6 o direct path (4.21.3) 5.6 Impact test on shield (4.21.4) Glow-wire test on lamp compartment 5.6 (4.22) Attachments to lamps o attachments 5.6 (4.23) Semi-luminaires comply class II 5.6 (4.24) UV radiation 5.6 (4.25) o sharp point or edges o sharp points or edges 5.6 (4.26) Short-circuit protection: 5.6 Uninsulated accessible SELV parts (4.26.1) 5.6 Short-circuit test (4.26.2) 5.6 (4.26.3) Test chain according to IEC (11) CREEAGE DISTACES AD CLEARACES age 12 of 44

13 Working voltage (V)...: Vac Voltage form Sinusoidal TI < 600V Rated pulse voltage (kv)... : -- (1) Current-carrying parts of different polarity: cr (mm); cl (mm)... : (2) Current-carrying parts and accessible parts: cr (mm); cl (mm)... : cr>2.5mm, cl>1.7mm required cr: 2.5mm, cl: 1.7mm cr>5.0mm, cl>3.4mm required cr: 5.0mm, cl: 3.4mm (3) arts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm)...: (4) Outer surface of cable where it is clamped and metal parts: cr (mm); cl (mm)...: (5) Current-carrying parts of switches and metal parts, after removal of insulation: cr (mm); cl (mm)...: (6) Current-carrying parts and supporting surface: cr (mm); cl (mm)...: cr>5.0mm, cl>3.4mm required cr: 5.0mm, cl: 3.4mm 5.8 (7) ROVISIO FOR EARTHIG 5.8 ( ) Accessible metal parts Metal parts in contact with supporting surface Resistance < 0,5 Ω 0.13Ω 5.8 ( ) Two self-tapping screws used Thread-forming screws Connector earthing first Earth continuity in joints etc. 5.8 (7.2.4) Locking of clamping means Compliance with (7.2.5) Earth terminal integral part of connector socket 5.8 (7.2.6) Earth terminal adjacent to mains terminals 5.8 (7.2.7) Electrolytic corrosion of the earth terminal 5.8 (7.2.8) Material of earth terminal on-rusting metal 5.8 (7.2.10) 5.8 (7.2.11) Contact surface bare metal Class II luminaire for looping-in Earthing core coloured green-yellow Length of earth conductor Rather than L and age 13 of 44

14 5.9 (14) SCREW TERMIALS Separately approved; component list art of the luminaire 5.9 (15) SCREWLESS TERMIALS Separately approved; component list art of the luminaire 5.10 (5) EXTERAL AD ITERAL WIRIG 5.10 (5.2) Supply connection and external wiring Means of connection... : ower cord not fitted with plug (5.2.1) 5.10 Type of cable... : H05VV-F (5.2.2) ominal cross-sectional area (mm²)...: 1.0 mm² 5.10 Type of attachment, X, Y or Z Type Y (5.2.3) 5.10 Type Z not connected to screws (5.2.5) 5.10 Cable entries: (5.2.6) suitable for introduction adequate degree of protection 5.10 (5.2.7) 5.10 (5.2.8) 5.10 (5.2.9) 5.10 (5.2.10) Cable entries through rigid material have rounded edges Insulating bushings: -- suitably fixed material in bushings - tubes or guards made of insulating material Locking of screwed bushings Cord anchorage: covering protected from abrasion clear how to be effective no mechanical or thermal stress no tying of cables into knots etc. insulating material or lining age 14 of 44

15 5.10 ( ) 5.10 ( ) 5.10 ( ) Cord anchorage for type X attachment: a) at least one part fixed b) types of cable c) no damaging of the cable d) whole cable can be mounted e) no touching of clamping screws f) metal screw not directly on cable g) replacement without special tool Glands not used as anchorage Labyrinth type anchorages AdequatecordanchoragefortypeYandtypeZ attachment Type Y Tests: -- impossible to push cable; unsafe pull test: 25 times; pull ()...: 60 torque test: torque (m)...: 0.15m displacement 2mm 0.3mm no movement of conductors no damage of cable or cord 5.10 External wiring passing into luminaire (5.2.11) 5.10 Looping in terminals (5.2.12) 5.10 Wire ends not tinned (5.2.13) Wire ends tinned: no cold flow 5.10 Mains plug same protection (5.2.14) Class III luminaire plug 5.10 Colour code low voltage (5.2.15) 5.10 Appliance inlets (IEC 60320) (5.2.16) Appliance couplers of class II type 5.10 (5.3) Internal wiring 5.10 Internal wiring of suitable size and type Suitable size (5.3.1) Through wiring -- age 15 of 44

16 5.10 ( ) - not delivered/ mounting instruction - factory assembled - socket outlet loaded (A)...: - temperatures... : Green yellow for earth only Internal wiring connected directly to fixed wiring 5.10 ( ) 5.10 ( ) 5.10 ( ) 5.10 ( ) 5.10 ( ) 5.10 (5.3.2) 5.10 (5.3.3) 5.10 (5.3.4) 5.10 (5.3.5) 5.10 (5.3.6) 5.10 (5.3.7) Cross-sectional area (mm²)...: Insulation thickness Extra insulation added where necessary Internal wiring connected to fixed wiring via internal current-limiting device Adequate cross-sectional area and insulation thickness Double or reinforced insulation for class II Conductors without insulation SELV current-carrying parts Insulation thickness other than VC or rubber Sharp edges etc. o moving parts of switches etc. Joints, raising/lowering devices Telescopic tubes etc. o twisting over 360 Openings Bushings not removable Bushings in sharp openings Cables with protective sheath Joints and junctions effectively insulated Strain on internal wiring Wire carriers Wire ends not tinned age 16 of 44

17 Wire ends tinned: no cold flow 5.11 (8) ROTECTIO AGAIST ELECTRIC SHOCK 5.11 Live parts not accessible (8.2.1) rotection in any position Double-ended tungsten filament lamp Insulation lacquer not reliable Double-ended high pressure discharge lamp o double-ended high pressure discharge lamp 5.11 (8.2.2) 5.11 (8.2.3) 5.11 (8.2.4) 5.11 (8.2.6) 5.11 (8.2.7) ortable luminaire adjusted in most unfavourable position Class II luminaire: basic insulated metal parts not accessible during starter or lamp replacement - basic insulation not accessible other than during starter or lamp replacement glass protective shields not used as supplementary insulation Class I luminaire with BC lampholder ortable luminaire: -- - protection independent of supporting surface terminal block completely covered Covers reliably secured Discharging of capacitors 0,5 μf ortable plug connected luminaire with capacitor o plug Other plug connected luminaire with capacitor Discharge device on or within capacitor Discharge device mounted separately 5.12 (12) EDURACE TEST AD THERMAL TEST 5.12 (12.3) Endurance test: mounting position...: ormal position test temperature ( C)...: 50 C total duration (h)...: 240h age 17 of 44

18 supply voltage: Un factor; calculated voltage (V) 240*1.1=264V... : lamp used...: LED lamp 5.12 After endurance test: -- (12.3.2) - no part unserviceable - luminaire not unsafe - no damage to track system - marking legible Marking still legible and shows no curling - no cracks, deformation etc (12.4) Thermal test (normal operation) (see Annex 2) 5.12 (12.5) Thermal test (abnormal operation) (see Annex 2) 5.12 Test Complied (12.5.1) a) According to the cases 1), 2), 3) or 4) below: 1) A possibly unsafe operating position, 2) Expiration of a lamp or of a starter (see Annex C). 3) Replacement of GLS lamp, 4) From a short circuit in the secondary circuit b) Test volatage c) Defective part of the luminaire (including the lamp d) The luminaire incorporates a capacitor e) For metal halide lamps and some high pressure sodium vapour lamps in accordance with b2) of Annex C (12.6) Thermal test (failed lamp control gear condition): case of abnormal conditions... : (12.6.1) electronic lamp control gear 5.12 (12.6.2) measured winding temperature ( C) at 1,1 Un. : measured mounting surface temperature ( C) at 1,1 Un... : calculated mounting surface temperature ( C). : track mounted luminaires Temperature sensing control -- case of abnormal conditions... : - thermal link age 18 of 44

19 - manual reset cut out - auto reset cut out measured mounting surface temperature ( C) : track mounted luminaires 5.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires): case of abnormal conditions... : 5.12 measured winding temperature ( C) at 1,1 Un. : (12.7.1) measured temperature of fixing point/ exposed part ( C) at 1,1 Un...: 5.12 (12.7.2) calculated temperature of fixing point/ exposed part ( C)...: Temperature sensing control -- - thermal link - manual reset cut out - auto reset cut out measured temperature of fixing point/ exposed part ( C)... : C shall be deducted 1.13 (9) RESISTACE TO DUST, SOLID OBJECTS AD MOISTURE 1.13 (9.2) Tests for ingress of dust, solid objects and moisture: -- classification according to I...: I65 mounting position during test...: ormal position fixing screws tightened; torque (m)...: tests according to clauses...: electric strength test afterwards a) no deposit in dust-proof luminaire b) no talcum in dust tight luminaire c) no trace of water on current-carrying parts or where it could become a hazard d) i) For luminaires without drain holes no water entry d) ii) For luminaires with drain holes no hazardous water entry e) no water in watertight luminaire f) no contact with live parts (I 2X) age 19 of 44

20 f) no entry into enclosure (I 3X and I 4X) 1.13 (9.3) Humidity test 48 h 30, 93% 5.14 (10) ISULATIO RESISTACE AD ELECTRIC STREGTH 5.14 Insulation resistance test (10.2.1) Insulation resistance (MΩ): SELV: between current-carrying parts of different polarity... : >2MΩ 5.14 (10.2.2) between current-carrying parts and mounting surface...: between current-carrying parts and metal parts of the luminaire...: > 2MΩ > 2MΩ Other than SELV: between live parts of different polarity...: >4MΩ between live parts and mounting surface... : > 4MΩ between live parts and enclosure...: > 4MΩ between live parts of different polarity through action of a switch... : Electric strength test Dummy lamp Luminaires with ignitors after 24 h test Luminaires with manual ignitors Test voltage (V): SELV: between current-carrying parts of different polarity... : between current-carrying parts and mounting surface...: between current-carrying parts and metal parts of the luminaire...: 500V 500V 500V Other than SELV: -- between live parts of different polarity...: 1480V between live parts and mounting surface... : 1480V between live parts and enclosure...: 1480V between live parts of different polarity through action of a switch... : age 20 of 44

21 5.14 (10.3.1) Leakage current (ma)... : 0.05mA 5.15 (13) RESISTACE TO HEAT, FIRE AD TRACKIG 5.15 (13.2.1) Ball-pressure test: - part tested; temperature ( C)...: Supporter of LED module 125 C,0.3mm 5.15 (13.3.1) 5.15 (13.3.2) 5.15 (13.3.3) 5.15 (13.4.1) - part tested; temperature ( C)...: Closed end connector: 125 C,0.1mm - part tested; temperature ( C)...: Wire end connector: 125 C, 0.1mm Glow wire test (750 C): -parttested...: Supporter of LED module, no flaming; -parttested...: Closed end connector: no flaming; Wire end connector: no flaming; Glow wire test (650 C): -parttested...: -parttested...: by failure to extinguish within 30 s after removal of the glow-wire tip, the needle-flame test in accordance with AS/ZS is made for 30 s on all parts of non-metallic material Tracking test: part tested... : age 21 of 44

22 ( ) COMMO MODIFICATIOS For luminaires connected by tails, information about terminal block (5.2.2) Cables equal to HD 21 S2 or HD 22 S2 (5.2.15) Colour code low voltage ZB AEX ZB, SECIAL ATIOAL CODITIOS (2.2) Class 0 not accepted (3.3) DK: power supply cord with label IT: warning label on Class 0 luminaire (4.5.1) DK: socket outlets (4.5.1) FR: socket-outlets (5.2.1) DK, FI, SE, GB: type of plug ZC AEX ZC, ATIOAL DEVIATIOS (13.3) DK: eedle flame test or glow-wire test 750 C for luminaires in access routes (13.3) GB: Requirements according to United Kingdom Building Regulation (13.3.2) FR: Glow-wire test 850 C alt.750 C for luminaires in premises open to public and workers Annex ZZ Variations to draft Ed.6 of IEC :2003 for application in Australia and ew Zealand In Australia, the supply voltage is 230 V/400 V +10% - 6% and for testing according to this Standard, the rated voltage shall be 240 V/415 V Material which does not comply with the glowwire test requirements of ; and material which can be easily ignited by spark, flame or hot surface when in contact with atmospheric oxygen and which can sustain a fire or explosion Includes plug-in night lights (which are intended to provide a source of low level illuminance in areas not normally illuminated at night).articular requirements for plug-in night lights is proposed to be covered in IEC in the future 2.2 Class 0 luminaires are not allowed in Australia and ew Zealand. Class I age 22 of 44

23 Delete the fifth paragraph and the ote and replace with the following: In Australia, luminaires with non-detachable flexible cables or cords which are intended to be connected to the supply via a socket-outlet and which are not fitted with a plug are not permitted. 3.3 Instructions and other texts required by this StandardshallbewritteninEnglish To avoid potential unsafe lamp failure, the luminaire should be switched off at least once a week Indoor and outdoor use (a) Suitability for use "indoors" including the related ambient temperature. (b) Suitability for outdoors temporary use. (c) Suitability for outdoors permanent use G5 lampholders are assessed for access to live parts during lamp replacements and with the lamp removed Suitability for use "outdoors" 40 C 4.16 Insert new Table 4.6 Surface mounted luminaires suitable for direct mounting on normally flammable surfaces: o symbol ortable luminaires with non detachable cables or cords shall be fitted with plugs complying with AS/ZS The plug portion of the luminaire with integral pins shall comply with Appendix J of AS/ZS Also see note under Clause Delete clause and replace with the following: Flexible cables or cords used as a means of connection to the supply, when supplied by the luminaire manufacturer, shall be at least equal in their mechanical and electrical properties to those specified in table 5.1, and shall be capable of withstanding, without deterioration, the highest temperature to which they may be exposed under normal conditions of use Installation couplers complying with AS/ZS 3131 or AS/ZS (Int) are an acceptable alternative in Australia and ew Zealand Luminaires other than ordinary, class I luminaires: H05VV-F For testing G5 lampholders, see Clause For Class I portable luminaires and luminaires for wall mounting within arm s reach (see Clause of AS/ZS 3000), terminal blocks shall be completely covered and it shall not be possible to touch basic insulation unless opened for replacement of lamps or replaceable control gear age 23 of 44

24 Add the following OTE to Table 12.1: OTE: Luminaire manufacturers are advised to consider maximum ambient air temperature of a component such as starting device, electronic ballast or converter etc. Component performance specifications advise manufacturers to mark or supply life data as maximum ambient air temperature based on 50,000 hrs. This t-lifetime is often marked as ta and is the temperature of the air in the vicinity of the component and is not related to the luminaire ta. Luminaire manufacturers are advised to measure air temperature in the vicinity of such components, within the luminaire, as even those complying with their tc point measurements can still fail prematurely if t-lifetime is exceeded. Consideration is being given to including this value in the above table in future editions Change the title to read: 12.6 Thermal test (failed lamp controlgear conditions) 13.3 Delete clause and replace with the following: 13.3 Resistance to flame and ignition Annex 0 Variations to IEC (1998) FOR ALICATIO I AUSTRALIA AD EW ZEALAD 5.1 SCOE: This part of AS/ZS specifies requirements for floodlights for use with tungsten filament, tubular fluorescent and other discharge lamps on supply voltages not exceeding V. It is to be read in conjunction with those sections of AS/ZS to which reference is made ormative references: The following normative documents contains provisions which, through reference in this text, constitute provisions of this section of AS/ZS At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this section of AS/ZS are encouraged to investigate the possibility of applying the most recent editions of the normative document indicated below. Members of IEC and ISO maintain registers of currently valid International Standards. 5.2 General test requirements: The provisions of section 0 of AS/ZS apply. The tests described in each appropriate section of AS/ZS shall be carried out in the order listed in this part. age 24 of 44

25 5.3 For the purposes of this part of AS/ZS , the definitions of section 0 of AS/ZS apply together with the following definitions: 5.4 Classification of luminaires Floodlights shall be classified in accordance with the provisions of section 2 of AS/ZS Marking: The provisions of section 3 of AS/ZS apply. 5.6 Construction: The provisions of section 4 of AS/ZS apply together with the requirements of to age 25 of 44

26 5.6.5 Cancel this clause: For floodlights for use above ground level outdoors, the connection shall withstand wind speeds of 150 km/h on the projected surface of the floodlight assembly without undue deflection. For floodlights for use above ground level outdoors, a constant evenly distributed load is applied for 10 min on the floodlight using sand-bags providing 4.5 k per square metre of floodlight projected area. The floodlight is then turned 180 in the vertical plane, about the point of attachment, and the test is repeated. OTE: This value of 4.5 k has been derived from AS based on parameters below: shielding, topographic and structure importance multipliers = 1.0. Region C, terrain Category 2 net draft coefficient = 1.2. Maximum mounting height = 20 meters. Wind speed = 250kmph. Floodlights used outside these parameters may be subject to alternative requirements. 5.7 Creepage distances and clearances: The provisions of section 11 of AS/ZS apply. 5.8 rovision for earthing: The provisions of section 7 of AS/ZS apply. 5.9 Terminals: The provisions of sections 14 and 15 of AS/ZS apply External and internal wiring: The provisions of section 5 of AS/ZS apply rotection against electric shock: The provisions of section 8 of AS/ZS apply Endurance tests and thermal tests: Luminaires with an I classification greater than I20 shall be subjected to the relevant tests of 12.4, 12.5 and 12.6 of section 12 of AS/ZS after the test(s) of 9.2 but before the test(s) of 9.3 of section 9 of AS/ZS specified in 5.13 of this part of AS/ZS The provisions of section 12 of AS/ZS apply, but with the following modification When applying the limits in the tables 12-1 to 12-6 of section 12 of AS/ZS to floodlights for use outdoors, 10 C shall be deducted from the temperatures measured on the floodlight in the test enclosure to allow for the effects of natural air movement which occur in the working environment of the floodlight. 0.9K applied o failure and movement for the point of attachment during testing. o permanent set exceeding 1 for the part of the test after testing. See component list age 26 of 44

27 5.13 Resistance to dust and moisture: The provisions of section 9 of AS/ZS apply. For luminaires with an I classification greater than I20, the order of the tests specified in section 9 of AS/ZS shall be as specified in 5.12 of this part of AS/ZS Insulation resistance and electric strength: The provisions of section 10 of AS/ZS apply Resistance to heat, fire and tracking: The provisions of section 13 of AS/ZS apply. object/part o. LED Driver Closed end connector Wire end connector silica gel Supply cord AEX 1: components manufac-turer/ trademark GLitter Heavy ower Co.,Ltd. Heavy ower Co.,Ltd. OSIO (SUZHOU) EW MATERIALS CO LTD DaZhengWire& Cable Mfg Ltd type/model technical data stan-dard mark(s) of conformity E-50W01- V45I VAC, 50/60Hz, Output:45VDC, 1.0A, Tc:70 C Ta:40 C IEC Ed 1.0; AS/ZS :2 002 SAA130497EA CE2/CE2X/CE5 150 C UL 486C UL E U1/U2/U3/U4 150 C UL 486C UL E SD-626 V E H05VV-F 3G 3x1.0mm2 AS/ZS :200 3+A1 SW (25492) AEX 2: temperature measurements, thermal tests of Section 12 Type reference... : 200W Lamp used... : LEDlamp Lamp control gear used... : LED DRIVER Mounting position of luminaire...: Asnormal Supply wattage (W)... : 200W Supply voltage (V)... : 254.4V Supply current (A)...: -- Calculated power factor... : F>0.9 Table: measured temperatures corrected for ta = 40 C: - abnormal operating mode... : age 27 of 44

28 -test1:ratedvoltage...: - test 2: 1,06 times rated voltage or 1,05 times rated wattage...: - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage...: 1.06*240=254.4V temperature ( C) of part clause normal clause abnormal test 1 test 2 test 3 limits test 4 limit Led driver Tc REF. Enclosure surface Ref Mounting surface Supply cord = Adjusting device Glass surface Ref Ambient AEX 3: screw terminals (part of the luminaire) (14) SCREW TERMIALS -- (14.2) Type of terminal... : Rated current (A)... : ( ) One or more conductors ( ) Special preparation ( ) Terminal size Cross-sectional area (mm²)...: (14.3.3) Conductor space (mm)... : (14.4) Mechanical tests -- (14.4.1) Minimum distance (14.4.2) Cannot slip out (14.4.3) Special preparation (14.4.4) ominal diameter of thread (metric ISO thread)..: External wiring o soft metal (14.4.5) Corrosion (14.4.6) ominal diameter of thread (mm)... : Torque (m)... : (14.4.7) Between metal surfaces Lug terminal age 28 of 44

29 Mantle terminal ull test; pull ()...: (14.4.8) Without undue damage AEX 4: SCREWLESS TERMIALS (ART OF THE LUMIAIRE) (15) SCREWLESS TERMIALS -- (15.2) Type of terminal... : Rated current (A)... : (15.3.1) Material (15.3.2) Clamping (15.3.3) Stop (15.3.4) Unprepared conductors (15.3.5) ressure on insulating material (15.3.6) Clear connection method (15.3.7) Clamping independently (15.3.8) Fixed in position ( ) Conductor size Type of conductor (15.5.1) Terminals internal wiring ( ) ull test spring-type terminals (4, 4 samples) ( ) ull test pin or tab terminals (4, 4 samples) Insertion force not exceeding 50 (15.5.2) ermanent connections: pull-off test (20 ) (15.6) Electrical tests Voltage drop (mv) after 1 h (4 samples)...: Voltage drop of two inseparable joints umber of cycles... : Voltagedrop(mV)after10thalt.25thcycle (4 samples)... : Voltagedrop(mV)after50thalt.100thcycle (4 samples)... : After ageing, voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : After ageing, voltage drop (mv) after 50th alt. 100th cycle (4 samples)...: (15.7) Terminals external wiring Terminal size and rating (15.8.1) ull test spring-type terminals (4 samples); pull () age 29 of 44

30 ull test pin or tab terminals (4 samples); pull () (15.9) Contact resistance test Voltagedrop(mV)after1h terminal voltage drop (mv) Voltage drop of two inseparable joints Voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) age 30 of 44

31 Annex ZZ VARIATIOS TO IEC , Ed. 7.0 (2008) FOR AUSTRALIA AD EW ZEALAD 0.1 Where the term lamp is used in this Standard, it is taken to include electric light sources. LED light sources are subject to the same test parameters as other discharge lamps. OTE It is recommended that portable, rechargeable, battery operated luminaires comply with AS/ZS , Annex B. In addition, portable, rechargeable, battery operated luminaires with lithium ion batteries should have overvoltage protection. 0.2 AS/ZS 3112, Approval and test specification plugs and socket-outlets AS/ZS 3133, Approval and test specification Air-break switches AS/ZS 3191, Electric flexible cords AS/ZS , Fire hazard testing art 11.10: Test flames 50 W horizontal and vertical flame test methods (IEC :1999, IDT) AS/ZS 61535, Installation couplers intended for permanent connection in fixed installations (IEC 61535, Ed. 1.0 (2009) MOD) IEC 61048, Auxilaries for lamps Capacitors for use in tubular fluorescent and other discharge lamp circuits General and safety requirements IEC 61049, Auxilaries for lamps Capacitors for use in tubular fluorescent and other discharge lamp circuits erformance requirements IEC , Devices for the connection of luminaires for household and similar purposes art 1: General In Australia, for equipment, other than class III equipment, that is intended for connection to the supply mains and not marked with: a rated voltage of at least 240 V for singlephase equipment or a rated voltage of at least 415 V for three-phase equipment; or a rated voltage range that includes 240 V for single-phase equipment and415 V for threephase equipment, the rated voltage is equal to 240 V for single-phase equipment and 415 V for three-phase equipment, and the upper limit of the voltage range is equal to 240 V for single-phase equipment and 415 V for three-phase equipment. 0.5 Throughout this document, where there is a relevant Australian/ew Zealand Standard, it replaces the IEC Standard unless otherwise specified V~ age 31 of 44

32 0.5.2A 0.5.2A Capacitors Capacitors shall comply with Clause 4.2A installation coupler connecting device consisting of an installation female connector and an installation male connector provided with retaining means for permanent connection not intended to be engaged or disengaged under load nor to be engaged or disengaged other than during first installation, during maintenance of the wiring system or during re-configuration of the wiring system installation male connector load side portion of an installation coupler which contains the male contacts installation female connector supply side portion of an installation coupler which contains the female contacts installation coupler system family of installation couplers consisting of one or more installation female connectors compatible by mechanical coding features with one or more installation male connectors, with the same ratings produced according to the specification of one manufacturer 2.2 Class 0 luminaires are not allowed in Australia or TABLE 3.1 ew Zealand. Move Item from the centre column to the right hand column In Australia, luminaires for household use and similar with supply cords which are not fitted with a plug shall be marked with a cord tag with the symbol for must be installed by a licensed electrician. (Refer to Figure ZZ1). Stick on supply cord 3.3 In Australia and ew Zealand, instructions and other texts required by this Standard shall be written in English. age 32 of 44

33 3.3.7 Luminaires for use with metal halide lamps shall be provided with instructions that state the substance of the following: To avoid potential unsafe lamp failure, the luminaire shall be switched off for at least 30 minutes at least once a week. In addition, the luminaire shall be operated: complete with its protective shield; or with a double jacketed lamp Delete Clause The instructions shall contain details related to components in the luminaire that require replacement as part of a maintenance program. 4.8 Switches that indicate an off position shall have contacts with an air break and comply with AS/ZS 3133 or AS/ZS A Capacitors shall be of a type to ensure that any capacitor failure results in a failsafe outcome (i.e. the capacitor type will fail in the open-circuit mode onlyand is protected against fire or shock hazard). Capacitors shall be not less than Type B capacitors with metal body and break action protection in accordance with IEC and IEC A capacitor complying with ACI/EIA-456-A shall comply with IEC and IEC 61048:2006 excluding the endurance test of OTE Capacitors of Class S2 (formerly referred to as 2) of IEC (all parts) do not meet the safety requirements of a Type B capacitor. In addition, capacitors shall have a minimum voltage rating of 250 V at a temperature rating of 100 C or 280 V at a temperature rating of 85 C. Capacitors likely to be permanently subjected to the supply voltage, and used for radio interference suppression or for voltage dividing, shall comply with IEC age 33 of 44

34 5.2.1 Luminaires shall be provided with only one of the following means of connection and isolation to the supply. Fixed luminaires: device for the connection of luminaires; terminals; plug for engagement with socketoutlets; connecting lead (tails); supply cord and plug; adapter for engagement with supply tracks; appliance inlet; installation coupler; luminaire coupler; ortable luminaires: supply cord with plug; appliance inlet. Track-mounted luminaires: adaptor; connector. Delete the second and third paragraph. Add the following text after ote 3: In Australia, non-portable luminaires with a supply cord shall be fitted with a plug complying with AS/ZS 3112 or a coupler complying with its standard, except where the luminaire has markings and instructions that comply with Clause , in which case, a plug or coupler is not required. However, for other than portable luminaires a plug is not required if the luminaire has markings and instructions in accordance with Clause The plug portion of a luminaire with integral pins shall comply with the relevant requirements of AS/ZS OTE 1 Relevant requirements for equipment with integral pins are outlined in AS/ZS OTE 2 VC-insulated connection cords should not be used with outdoor luminaires in cold alpine locations Supply cords used as a means of connection to the supply, when supplied by the luminaire manufacturer, shall be at least equal in their mechanical and electrical properties to those specified in IEC and IEC 60245, as indicated in Table 5.1, or AS/ZS 3191, and shall be capable of withstanding, without deterioration, the highest temperature to which they may be exposed under normal conditions of use. Table 5.1, delete rows 4 and 5 and replace with the following: Cord age 34 of 44

35 To provide adequate mechanical strength, the nominal cross-sectional area of the conductors shall be not less than: 0,75mm2; 1,0mm2 for portable rough service luminaires Class II luminaires for fixed wiring incorporating an appliance coupler shall not have means to allow further luminaires to be connected, including looping in by cascading. Luminaire couplers incorporated with the luminaire shall comply with IEC All portable luminaires with a flexible supply cord shall be fitted with a plug complying with AS/ZS Other luminaires with flexible cords shall be fitted with a plug complying with AS/ZS 3112, unless they have the warning allowed by Clause Installation couplers incorporated within luminaires shall comply with the requirements of AS/ZS Luminaires incorporating installation couplers may have means to allow further luminaires to be connected by cascading provided the through wiring is rated for the current rating of the installation coupler Internal wires coloured green, yellow or green/yellow combination shall be used for making protective earth connections only. Functional earth connections shall not be made by wires coloured green, yellow or green/yellow combination. OTE 3 Internal wires of other colours are not precluded from making protective earthing connections All conductors, whether internal or external, coloured green, yellow or green/yellow combination, shall only be connected to an earthing terminal. 1.0 mm2 age 35 of 44

36 8.2.1 Luminaires shall be so constructed that their live parts and basic insulation are not accessible when the luminaire has been installed and wired as in normal use. Live parts shall not be accessible when the luminaire is opened as necessary for replacing lamps, replaceable light sources or (replaceable) starters, even if the operation cannot be achieved by hand. OTE Examples of parts with basic insulation are cables intended for internal wiring, controlgear for building-in etc. This does not apply to the non-current -carrying parts of caps which comply with the relevant IEC safety standard. Where a protective cover is used over a non-user-replaceable light source to provide protection against electric shock, and the cover is marked with the caution, electric shock risk symbol in accordance with IEC , the cover shall be left in place during the tests and inspections detailed by Section 8 of this Standard. The cover shall be held securely in position by fixings requiring the use of a tool for their removal, and at least two independent fixings shall be used. TABLE 12.1 OTE Luminaire manufacturers should consider the maximum ambient air temperature in the vicinity of components such as starting devices and electronic ballasts or converters. Component performance specifications advise manufacturers to mark or supply life data as maximum ambient air temperature based on 50,000 hrs. This t-life is often marked as ta and is the temperature of the air in the vicinity of the component and is not related to the luminaire ta. As such, luminaire manufacturers should measure air temperature in the vicinity of such components, within the luminaire, as even those complying with their tc point measurements can still fail prematurely if t-life is exceeded arts of non-metallic material shall be resistant to flame and ignition. For materials other than ceramic, compliance is checked by the tests of and , and , as appropriate. This requirement does not apply to decorative trims, knobs, wiring insulation and other parts not likely to be ignited or to propagate flames from inside the luminaire. This Clause applies to all parts, including components, even if they have been tested to their own standard. age 36 of 44

37 arts of non-metallic material supporting connections shall withstand the following test: arts are subject to a test using a nickelchromium glow-wire. The test apparatus and test procedure shall be those described in AS/ZS The glow wire is heated to 750 C and applied to the test sample for 30 s. For all tests, any flame or glowing of the sample shall extinguish within 30 s of withdrawing the glow-wire, and any burning or molten drop shall not ignite a single layer of tissue paper specified in of ISO :2002, spread out horizontally 200 mm ± 5 mm below the sample All other parts of non-metallic material shall withstand the following test: arts are subject to a test using a nickelchromium glow-wire. The test apparatus and test procedure shall be those described in AS/ZS The glow wire is heated to 650 C and applied to the test sample for 30 s. For all tests, any flame or glowing of the sample shall extinguish within 30 s of withdrawing the glow-wire, and any burning or molten drop shall not ignite a single layer of tissue paper specified in of ISO :2002, spread out horizontally 200 mm ± 5 mm below the sample. Wire end connector age 37 of 44

38 During the application of the 750 C glow wire test of Clause , if a flame is produced that persists for longer than 2 s, the luminaire is further tested as follows: The needle-flame test of AS/ZS is applied to non-metallic parts that encroach within the envelope of a vertical cylinder having a diameter of 20 mm and a height of 50 mm above the point of application of the glow wire. The needle flame is applied to the test sample for 30 s. arts shielded by a barrier that meets the needleflame test of AS/ZS are not tested. OTE This requires the needle flame to be applied to all parts likely to be impinged upon by the glow-wire flame within the hypothetical envelope of a vertical cylinder positioned above the point of application of the glow-wire. This applies to all parts unless there is a barrier that passes the needle-flame test and is within the cylinder and would protect the part from the glowwire flame. The duration of burning shall not exceed 30 s after removal of the test flame and any burning drop shall not ignite the underlying parts or tissue paper specified in of ISO :2002, spread out horizontally 200 mm ± 5 mm below the sample. The needle-flame test is not carried out on parts that are made of material classified as V-0 or V-1 according to AS/ZS The sample of material classified in accordance with AS/ZS shall be no thicker than the relevant part CBs in luminaires shall be subject to the needleflame test of AS/ZS The needle flame shall be applied for 30 seconds to an edge of the CB at least 10 mm from a corner. The duration of burning shall not exceed 15 s after removal of the needle flame and any burning droplets shall not ignite the tissue paper placed underneath the CB. The needle-flame test is not carried out on CBs made of material that is V-0 rated according to AS/ZS age 38 of 44

39 Annex5: Deviations Between Standard IEC :2007 and AS/ZS :2002 AS/ZS AS/ZS General notes on tests For Australia, the rated supply voltage is 230 V/400 V +10%, -6% and for testing according to this Standard, the rated test voltage shall be 240 V/415 V. TERMIALS Screw terminals: compliance with Section 14 of AS/ZS Screwless terminals: compliance with Section 15 of AS/ZS Cables and cords shall comply with the relevant requirements of Section 5 of AS/ZS AS/ZS.61 RESISTACE TO HEAT, FIRE AD TRACKIG arts of insulating material retaining live parts in position, ball-pressure test: - past tested; temperature ( C ) C, 1hr conducted: for Wire end connector, 0.2 mm<2 mm Retaining current carrying part in position glowwire test 750 C External parts of insulating material preventing electric shock glow-wire test 650 C The surrounding parts are subject to the needleflame test 30s Wire end connector: no flaming 18.3 Tracking test age 39 of 44

40 AEX A: hoto-documentation hoto 1 hoto 2 age 40 of 44

41 hoto 3 hoto 4 age 41 of 44

42 hoto 5 hoto 6 age 42 of 44

43 hoto 7 hoto 8 age 43 of 44

44 hoto 9 hoto 10 ****** ED OF REORT ****** age 44 of 44

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa

Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz

More information

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno

Report o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct

More information

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S

LVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)

Shenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT) Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB13035196 Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR

More information

Test Report issued under the responsibility of:

Test Report issued under the responsibility of: age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in

More information

EN : MEASUREMENT AND TEST REPORT For

EN : MEASUREMENT AND TEST REPORT For E 60598-1: 2004 MEASUREMET AD TEST REORT For LOGSTAR LIGHTIG GROU TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, China Model:LS-T8-T600S1,LS-T8-T900S1,LS-T8-T1200S1,LS-T8-T1500S1,LS-T8-M600S1,

More information

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting

TEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting TEST REORT AS/ZS 60598.2.3:2015 Luminaires art 2.3: articular requirements Luminaires for road and street lighting Report Reference o.... : RSZ170419551-03 Compiled by (+ signature)... : Andy Fu Approved

More information

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China

Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China Summary of testing: Tests performed (name of test and test clause): The submitted samples were found to comply with the requirements of: -- E 60598-2-2:2012 -- E 60598-1:2008+A11:2009 Testing location:

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements Section 1: Fixed general purpose luminaires Report Number.... : 64.140.11.02922.03 Date of issue... : 2015-02-02 Total number of pages...

More information

Page 1 of 27 Report No. : HT15DR LVD Test Report

Page 1 of 27 Report No. : HT15DR LVD Test Report age 1 of 27 LVD Test Report EN60598-1&EN60598-2-1 art 1:General requirement and tests art 2: articular requirments Section One Fixed general purpose luminaires Report reference No.......: HT15DR-120321

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Number.... : 17041854 001 Date of

More information

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598.

Compliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598. Doc Id: AS/ZS60598.2.1:2014+A1 Report o: 0803BSS-61900_59821 age 1 of 49 Compliance Testing Report for Australian/ew Zealand Standard AS/ZS 60598.2.1: 2014 Inc Amendment 1 in conjunction with AS/ZS60598.1:2013

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date

More information

CENTRE OF TESTING SERVICE INTERNATIONAL

CENTRE OF TESTING SERVICE INTERNATIONAL CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CGZ3150109-00114-L-F GZ test site: A101, o.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REORT Luminaires art 2.1: articular requirements Fixed general purpose luminaires Accredited for compliance with ISO/IEC 17025 Report Reference No.... : S17031 Compiled by (+ signature)... : Yongchan

More information

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights

TEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights TEST REORT EN 60598-2-21 Luminaires art 2: articular requirements Section 21: Rope Lights Report reference No.... : ED170727001S Tested by... : Coral Chen Approved by... : Kobe Mai Date of issue... : August

More information

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED

SAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED age 1 of 47 Report o. R011501451I SAA TEST REORT On Behalf of AOK LED LIGHT COMAY LIMITED LED Street Light Model: AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL,

More information

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires

TEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires Report Reference o....: Compiled by (+ signature)...: Approved by (+ signature)... : TEST REORT AS/ZS 60598.2.1 Luminaires art 2: articular requirements: Fixed general purpose luminaires RSZ160822550-03

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050805SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan Road,

More information

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires

TEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires TEST REORT Luminaires art 1: General requirements and Tests art 2: articular requirements - Section 4: ortable general purpose luminaires Report Reference o: Tested by: T1321-21-12 Urs Wyttenbach Approved

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Report o.: BSTDG13050811SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For : SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires

TEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires Test Report issued under the responsibility of: TEST REORT E 60598-2-2: 1996 LUMIAIRES --- SAFETY--- ART 2-2: articular requirements- Recessed luminaires Report reference o...: GTSS12080044101 Compiled

More information

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires TEST REORT EN 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No...: 3007562.50-QUA/LI Date of issue...: 2011-03-28 Total number of pages...

More information

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED LVD REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED

SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED LVD REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED Shenzhen BST Technology Co., Ltd Report o.: BSTDG13050806SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED LVD REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires age 1 of 40 TEST REORT IEC 60598-2-2 Luminaires art 2: articular requirements Section 2: Recessed luminaires Report Number.... : 7040216100405-00 Date of issue... : 2016-11-18 Total number of pages...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No....: TGM-VA EE32453 SFT Date of issue...

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Test Report issued under the responsibility of: Studio Oleandri - Milano TEST REPORT IEC 60598-2-1 Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Report Number...

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd

APPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd age 1 of 55 Report o. R011607605S-1 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co.,Ltd LED Flood Light Model: QH-FLXH01-50W, QH-FLXH02-100W, QH-FLXH03-150W, QH-FLXH04-200W,

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

TEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD

TEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD Report o.: BST14090471Y-1SR-2 SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD TEST REORT repared For : SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD 4F,Building A,YouXinDa Industrial Area, GenYu Road,TianLiao

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark :

CERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark : CERTIFICATE of Conformity Reference o. : LCS1702161029S 001 Applicant : LOKOLED Address : Kitmanstraat 14 1812 M Alkmaar The etherlands Trademark : /A roduct : LED Downlight Model(s) : (see attached) arameters

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic

More information

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff

More information

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd.

TEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd. TEST REORT Reference o.... : WTF15F0730677S Applicant... : Foshan anhai Vorld Lighting Co., Ltd. Address... : 18th west Taoyuan Road, Shishan Town, anhai District, Foshan City, Guangdong rovince Manufacturer...

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

TEST REPORT IEC LED modules for general lighting Safety specifications

TEST REPORT IEC LED modules for general lighting Safety specifications Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant

More information

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests

TEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests Test Report issued under the responsibility of: Report Reference o...: age 1 of 11 TEST REORT IEC 60968 and/or E 60968 Luminaires art 1: General Requirements And Tests GTSS12060031301 Date of issue...:

More information

LIA Laboratories Limited

LIA Laboratories Limited LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,

More information

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82 age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang

More information

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires

TEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:

More information

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment):

Page 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment): age 3 of 90 Report No.: 17052930 001 List of Attachments (including a total number of pages in each attachment): Attachment 1: 12 pages of photos. Summary of testing: Tests performed (name of test and

More information

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing

More information

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007

Test Report No. 55S071315/ZHY/PKS dated 10 JUL 2007 Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are

More information

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 1540-44-I Date of issue... : 2016-09-01

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Remark: Whether parts of tests for the product have been subcontracted to other labs:

Remark: Whether parts of tests for the product have been subcontracted to other labs: Reference o.: WTS16S1166817S age 2 of 60 Test item description...: Trademark...: Model and/or type reference...: AU-BD350VA Rating(s)... : 220-240V~, 50Hz, Max. 350VA, Min 10VA Remark: Whether parts of

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances

TEST REPORT IEC and/or EN Safety of household and similar electrical appliances - age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total

More information

For. Shanghai Moons Automation Control Co., Ltd.

For. Shanghai Moons Automation Control Co., Ltd. Shenzhen BCTC Technology Co., Ltd. Report o.: BCTC-13080904S ALICATIO FOR LVD For Shanghai Moons Automation Control Co., Ltd. roduct ame: LED drivers Trademark: Model : repared For : MU096A024A, MU096A175AQD

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3112:2011 AS/NZS 3112:2011 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets AS/NZS 3112:2011 This Joint Australian/New Zealand Standard was prepared by Joint

More information

TEST REPORT EN Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules

TEST REPORT EN Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules TEST REORT E 61347-2-13 Lamp controlgear art 2-13: articular requirements for d.c. or a.c. supplied electronic controlgear for LED modules Report umber.... : TCDQ02170721805S-LD01 Date(s) of performance

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting

TEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 6011995.50 Date of issue... :

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

Page 3 of 32 Report No Summary of testing:

Page 3 of 32 Report No Summary of testing: age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.

More information

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PORTABLE DATE: JULY 2006 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD...3 INTRODUCTION...4 1 SCOPE...4 2 NORMATIVE S...4 3 DEFINITIONS AND ABBIATIONS...4 4 REQUIREMENTS...5 4.1

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires

TEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Test Report issued under the responsibility of: TEST REPORT Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Report Reference No...: HZ10120073-001 ate of issue...:

More information

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Menu. Home About this portal Latest updates. Print Save  Resource detail Citations. Table of Contents Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60898.1:2004 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar

More information

AS/NZS :2013. Plugs and socket-outlets for household and similar purposes AS/NZS :2013

AS/NZS :2013. Plugs and socket-outlets for household and similar purposes AS/NZS :2013 AS/NZS 60884.1:2013 Australian/New Zealand Standard Plugs and socket-outlets for household and similar purposes Part 1: General requirements (IEC 60884-1, Ed.3.1 (2006) MOD) AS/NZS 60884.1:2013 AS/NZS

More information

Test report: 13/ Date January 20 th,2014 Page 1 of 52

Test report: 13/ Date January 20 th,2014 Page 1 of 52 LGAI LGAI Technological Center, S.A. Campus de la UAB Apartado de Correos 18 E - 08193 Bellaterra (Barcelona) T +34 93 567 20 00 F +34 93 520 20 01 www.appluslaboratories.com TEST REORT Test report: 13/31705080

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of

More information

TEST REPORT IEC Connectors Safety requirements and tests

TEST REPORT IEC Connectors Safety requirements and tests IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 70.410.14.127.01-01 Date of issue... : 2014-07-03 Total number of pages... 61

More information

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016

More information

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION IEC TS 62735-1 Edition 1.0 2015-08 colour inside Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60884-1 Edition 3.1 2006-07 Edition 3:2002 consolidated with amendment 1:2006 Plugs and socket-outlets for household and similar purposes Part 1: General requirements IEC 2006

More information

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical

More information

PIL0478 ISSUE 01/ 07/16

PIL0478 ISSUE 01/ 07/16 ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW

More information

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder. ALICATION FOR CONSTRUCTION RODUCTS DIRECTIVE On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder Model No: 385T repared For : repared By : Shenzhen Changen Industry Co.,Ltd.

More information

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools Part 2: Particular requirements for drills and impact drills Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools art 2: articular requirements for drills and impact drills Report reference No.... : 3130837.50A

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of TEST REORT IEC 60884-1 lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 2228900-1520-0001/175202

More information

SHA-001 Date of issue...: Total number of pages Report Reference No...:

SHA-001 Date of issue...: Total number of pages Report Reference No...: TEST REORT lugs and socket-outlets for household and similar purposes art 2-1: General requirements on plugs and portable socket-outlets Report Reference No....: 130600884SHA-001 Date of issue...: 2013-07-09

More information