Summary of testing: Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China
|
|
- Caroline Stephens
- 5 years ago
- Views:
Transcription
1
2
3 Summary of testing: Tests performed (name of test and test clause): The submitted samples were found to comply with the requirements of: -- E : E :2008+A11:2009 Testing location: 1/F, Block East H-3, OCT Eastern Ind. Zone, Qiaocheng East Road, nanshan, Shenzhen, China -- E : A1: E : E 62031:2008 Summary of compliance with ational Differences: /A Copy of marking plate: colonbo LED Ceiling Lamp Model: CL-TA02526CBAB Input: V~ 50/60Hz 25W age 2 of 45 Report o.: BCT13GR-1275S
4 Test item particulars... : Classification of installation and use... : Supply Connection... : Built-in appliance and Class II Fixed wire...:...: ossible test case verdicts: - test case does not apply to the test object...: /A (ot applicable) - test object does meet the requirement...: (ass) - test object does not meet the requirement...: F (Fail) Testing...: Date of receipt of test item...: July 03, 2013 Date (s) of performance of tests...: July 03-16, 2013 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report. ote: E Group Differences together with ational Differences and Special ational Conditions, if any, are in the Appendix to the main body of this TRF. Throughout this report a comma (point) is used as the decimal separator. Clause numbers between brackets refer to clauses in IEC Appendix 1: Test report for E :2006 Appendix 2: Test report for E 62031:2008 Appendix 3: hoto documentation General product information: The LED Ceiling Light is Built-in SELV control gear with LED lamp. The LED Ceiling Light for general service luminaires. These models are the same structure, but different power appearance and colour temperature. Unless otherwise specified, the model CL-TA02526CBAB is selected as representative models to perform all tests age 3 of 45 Report o.: BCT13GR-1275S
5 E (0) GEERAL TEST REQUIREMETS 2.2 (0.1) Information for luminaire design considered Standard Yes o 2.2 (0.3) More sections applicable... : Yes o 2.4 (2) CLASSIFICATIO 2.4 (2.2) Type of protection... : Class II 2.4 (2.3) Degree of protection (Requirement: Ordinary)... : I (2.4) Luminaire only suitable for non-combustible surfaces... : Luminaire suitable for normally flammable surfaces... : Luminaire suitable to be covered by insulating material... : Yes o Yes o Yes o 2.4 (2.5) Luminaire for normal use... : Yes o Luminaire for rough service... : Yes o 2.5 (3) MARKIG 2.5 (3.2) Mandatory markings osition of the marking See the label Format of symbols/text 2.5 (3.3) Additional information Language of instructions English 2.5 (3.3.1) Combination luminaires 2.5 (3.3.2) ominal frequency in Hz 50/60Hz 2.5 (3.3.3) Operating temperature 2.5 (3.3.4) Symbol or warning notice 2.5 (3.3.5) Wiring diagram 2.5 (3.3.6) Special conditions 2.5 (3.3.7) Metal halide lamp luminaire warning LED luminaire 2.5 (3.3.8) Limitation for semi-luminaires 2.5 (3.3.9) ower factor and supply current 2.5 (3.3.10) Suitability for use indoors 2.5 (3.3.11) Luminaires with remote control age 4 of 45 Report o.: BCT13GR-1275S
6 E (3.3.12) Clip-mounted luminaire warning 2.5 (3.3.13) Specifications of protective shields 2.5 (3.3.14) Symbol for nature of supply ~ 2.5 (3.3.15) Rated current of socket outlet 2.5 (3.3.16) Rough service luminaire 2.5 (3.3.17) Mounting instruction for type Y, type Z and some type X attachments Type Y 2.5 (3.3.18) on-ordinary luminaires with VC cable Rubber cable 2.5 (3.4) Test with water Test with hexane Legible after test Label attached 2.6 (4) COSTRUCTIO 2.6 (4.2) Components replaceable without difficulty o component replaceable 2.6 (4.3) Wireways smooth and free from sharp edges 2.6 (4.4) Lampholders 2.6 (4.4.1) Integral lampholder o lampholder used 2.6 (4.4.2) Wiring connection 2.6 (4.4.3) Lampholder for end-to-end mounting 2.6 (4.4.4) ositioning - pressure test ()... : - bending test ()... : 2.6 (4.4.5) eak pulse voltage 2.6 (4.4.6) Centre contact 2.6 (4.4.7) arts in rough service luminaires resistant to tracking 2.6 (4.4.8) Lamp connectors 2.6 (4.4.9) Caps and bases correctly used 2.6 (4.5) Starter holders Starter holder in luminaires other than class II o starter holder used Starter holder class II construction 2.6 (4.6) Terminal blocks Tails age 5 of 45 Report o.: BCT13GR-1275S
7 E Unsecured blocks 2.6 (4.7) Terminals and supply connections 2.6 (4.7.1) Contact to metal parts 2.6 (4.7.2) Test 8 mm live conductor Test 8 mm earth conductor 2.6 (4.7.3) Terminals for supply conductors 2.6 ( ) Welded connections: - stranded or solid conductor - spot welding - welding between wires - Type Z attachment - mechanical test according to electrical test according to heat test according to and (4.7.4) Terminals other than supply connection 2.6 (4.7.5) Heat-resistant wiring/sleeves 2.6 (4.7.6) Multi-pole plug o multi-pole plug used - test at (4.8) Switches: - adequate rating o switch used - adequate fixing - polarized supply - compliance with for electronic switches 2.6 (4.9) Insulating lining and sleeves 2.6 (4.9.1) Retainment Method of fixing... : 2.6 (4.9.2) Insulated linings and sleeves a) & c) Insulation resistance and electric strength b) Ageing test. Temperature ( C)... : 2.6 (4.10) Insulation of Class II luminaires 2.6 (4.10.1) o contact, mounting surface accessible metal parts wiring of basic insulation Safe installation fixed luminaires age 6 of 45 Report o.: BCT13GR-1275S
8 E Capacitors and switches Interference suppression capacitors according to IEC (4.10.2) Assembly gaps: - not coincidental - no straight access with test probe 2.6 (4.10.3) Retainment of insulation: - fixed - unable to be replaced; luminaire inoperative - sleeves retained in position - lining in lampholder 2.6 (4.11) Electrical connections 2.6 (4.11.1) Contact pressure 2.6 (4.11.2) Screws: - self-tapping screws - thread-cutting screws - at least two self-tapping screws 2.6 (4.11.3) Screw locking: - spring washer - rivets 2.6 (4.11.4) Material of current-carrying parts 2.6 (4.11.5) o contact to wood 2.6 (4.11.6) Electro-mechanical contact systems 2.6 (4.12) Mechanical connections and glands 2.6 (4.12.1) Screws not made of soft metal Screws of insulating material Torque test: torque (m); part... : Screws for fixing enclosure 0.5m, tested and no damage Torque test: torque (m); part... : Screws for fixing lamp cover 0.5m, tested and no damage Torque test: torque (m); part... : 2.6 (4.12.2) Screws with diameter < 3 mm screwed into metal 2.6 (4.12.4) Locked connections: - fixed arms; torque (m)... : 2.5 m age 7 of 45 Report o.: BCT13GR-1275S
9 E fixed arms; torque (m)... : - lampholder; torque (m)... : - push-button switches; torque 0,8 m... : 2.6 (4.12.5) Screwed glands; force ()... : 2.6 (4.13) Mechanical strength 2.6 (4.13.1) Impact tests: - fragile parts; energy (m)... : Lampshade: 0.20 m - other parts; energy (m)... : 0.35m for other parts 1) live parts 2) linings 3) protection 4) covers 2.6 (4.13.3) Straight test finger 2.6 (4.13.4) Rough service luminaires - I54 or higher a) fixed b) hand-held c) delivered with a stand d) for temporary installations and suitable for mounting on a stand 2.6 (4.13.6) Tumbling barrel 2.6 (4.14) Suspensions and adjusting devices 2.6 (4.14.1) Mechanical load: A) four times the weight B) torque 2,5 m C) bracket arm; bending moment (m)... : D) load track-mounted luminaires E) clip-mounted luminaires, glass-shelve. Thickness (mm)... : metal rod. diameter (mm)... : Fixed luminaire or independent control gear without fixing devices 2.6 (4.14.2) Load to flexible cables Mass (kg)... : age 8 of 45 Report o.: BCT13GR-1275S
10 E Stress in conductors (/mm²)... : Mass (kg) of semi-luminaire... : Bending moment (m) of semi-luminaire... : 2.6 (4.14.3) Adjusting devices: - flexing test; number of cycles... : - strands broken - electric strength test afterwards 2.6 (4.14.4) Telescopic tubes: cords not fixed to tube; no strain on conductors 2.6 (4.14.5) Guide pulleys 2.6 (4.14.6) Strain on socket-outlets 2.6 (4.15) Flammable materials: - glow-wire test 650 C - spacing 30 mm - screen withstanding test of screen dimensions - no fiercely burning material - thermal protection - electronic circuits exempted 2.6 (4.15.2) Luminaires made of thermoplastic material with lamp control gear a) construction b) temperature sensing control c) surface temperature 2.6 (4.16) Luminaires marked with F-symbol o lamp control gear (compliance with Section 12) 2.6 (4.16.1) Lamp control gear spacing: - spacing 35 mm - spacing 10 mm 2.6 (4.16.2) Thermal protection: - in lamp control gear - external - fixed position - temperature marked lamp control gear age 9 of 45 Report o.: BCT13GR-1275S
11 E (4.16.3) F curve measured (see 12.6) 2.6 (4.17) Drain holes Clearance at least 5 mm 2.6 (4.18) Resistance to corrosion: 2.6 (4.18.1) - rust-resistance 2.6 (4.18.2) - season cracking in copper 2.6 (4.18.3) - corrosion of aluminium 2.6 (4.19) Ignitors compatible with ballast 2.6 (4.20) Rough service vibration 2.6 (4.21) rotective shield: 2.6 (4.21.1) Shield fitted 2.6 (4.21.2) articles from a shattering lamp not impair safety 2.6 (4.21.3) o direct path 2.6 (4.21.4) Impact test on shield Glow-wire test on lamp compartment 2.6 (4.22) Attachments to lamps 2.6 (4.23) Semi-luminaires comply Class II 2.6 (4.24) UV radiation, metal halide lamps 2.6 (4.25) o sharp point or edges 2.6 (4.26) Short-circuit protection: 2.6 (4.26.1) Uninsulated accessible SELV parts 2.6 (4.26.2) Short-circuit test 2.6 (4.26.3) Test chain according to Figure (11) CREEAGE DISTACES AD CLEARACES Working voltage (V)... : V~ Voltage form Sinusoidal on-sinusoidal TI < 600 > 600 Rated pulse voltage (kv)... : (1) Current-carrying parts of different polarity: cr (mm); cl (mm)... : Between different polarities of CB: cr.>3.0mm, cl.>3.0mm; [limit cr.2,5mm, cl.1,5mm] age 10 of 45 Report o.: BCT13GR-1275S
12 E (2) Current-carrying parts and accessible parts: cr (mm); cl (mm)... : (3) arts becoming live due to breakdown of basic insulation and metal parts: cr (mm); cl (mm)... : (4) Outer surface of cable where it is clamped and metal parts: cr (mm); cl (mm)... : Between live part of and metal enclosure: cr.>3.0mm, cl.>3.0mm; [limit cr.2,5mm, cl.1,5mm] (5) ot used (6) Current-carrying parts and supporting surface: cr (mm); cl (mm)... : Between live part of and supporting surface: cr.>3.0mm, cl.>3.0mm; [limit cr.2,5mm, cl.1,5mm] 2.8 (7) ROVISIO FOR EARTHIG 2.8 ( ) Accessible metal parts 2.8 ( ) Metal parts in contact with supporting surface Resistance < 0,5 Ω Two self-tapping screws used Thread-forming screws Thread-forming screw used in a grove Earth makes contact first Earth continuity in joints etc. 2.8 (7.2.4) Locking of clamping means Compliance with (7.2.5) Earth terminal integral part of connector socket 2.8 (7.2.6) Earth terminal adjacent to mains terminals 2.8 (7.2.7) Electrolytic corrosion of the earth terminal 2.8 (7.2.8) Material of earth terminal Contact surface bare metal 2.8 (7.2.10) Class II luminaire for looping-in Double or reinforced insulation to functional earth 2.8 (7.2.11) Earthing core coloured green-yellow Length of earth conductor age 11 of 45 Report o.: BCT13GR-1275S
13 E (14) SCREW TERMIALS Separately approved; component list (see Annex 1), art of the luminaire (see Annex 3) 2.9 (15) SCREWLESS TERMIALS AD ELECTRICAL COECTIOS Separately approved; component list (see Annex 1) art of the luminaire (see Annex 4) 2.10 (5) EXTERAL AD ITERAL WIRIG 2.10 (5.2) Supply connection and external wiring 2.10 (5.2.1) Means of connection... : Fixed wire 2.10 (5.2.2) Type of cable... : ominal cross-sectional area (mm²)... : Cables equal to IEC or IEC (5.2.3) Type of attachment, X, Y or Z Type Y 2.10 (5.2.5) Type Z not connected to screws 2.10 (5.2.6) Cable entries: - suitable for introduction - adequate degree of protection 2.10 (5.2.7) Cable entries through rigid material have rounded edges 2.10 (5.2.8) Insulating bushings: - suitably fixed - material in bushings - material not likely to deteriorate - tubes or guards made of insulating material 2.10 (5.2.9) Locking of screwed bushings 2.10 (5.2.10) Cord anchorage: - covering protected from abrasion - clear how to be effective - no mechanical or thermal stress - no tying of cables into knots etc. - insulating material or lining age 12 of 45 Report o.: BCT13GR-1275S
14 E ( ) Cord anchorage for type X attachment: a) at least one part fixed b) types of cable c) no damaging of the cable d) whole cable can be mounted e) no touching of clamping screws f) metal screw not directly on cable g) replacement without special tool Glands not used as anchorage Labyrinth type anchorages 2.10 ( ) Adequate cord anchorage for type Y and type Z attachment Type Y 2.10 ( ) Tests: - impossible to push cable; unsafe - pull test: 25 times; pull ()... : - torque test: torque (m)... : - displacement 2 mm - no movement of conductors - no damage of cable or cord 2.10 (5.2.11) External wiring passing into luminaire 2.10 (5.2.12) Looping-in terminals 2.10 (5.2.13) Wire ends not tinned Wire ends tinned: no cold flow 2.10 (5.2.14) Mains plug same protection Class III luminaire plug 2.10 (5.2.16) Appliance inlets (IEC 60320) Appliance couplers of class II type 2.10 (5.2.17) o standardized interconnecting cables properly assembled 2.10 (5.2.18) Used plug in accordance with - IEC other standard 2.10 (5.3) Internal wiring age 13 of 45 Report o.: BCT13GR-1275S
15 E (5.3.1) Internal wiring of suitable size and type Through wiring - not delivered/ mounting instruction - factory assembled - socket outlet loaded (A)... : - temperatures... : (see Annex 2) Green-yellow for earth only 2.10 ( ) Internal wiring connected directly to fixed wiring Cross-sectional area (mm²)... : 0.75mm 2 Insulation thickness Extra insulation added where necessary 2.10 ( ) Internal wiring connected to fixed wiring via internal current-limiting device Adequate cross-sectional area and insulation thickness 2.10 ( ) Double or reinforced insulation for class II 2.10 ( ) Conductors without insulation 2.10 ( ) SELV current-carrying parts 2.10 ( ) Insulation thickness other than VC or rubber 2.10 (5.3.2) Sharp edges etc. o moving parts of switches etc. Joints, raising/lowering devices Telescopic tubes etc. o twisting over (5.3.3) Insulating bushings: - suitable fixed - material in bushings - material not likely to deteriorate - cables with protective sheath 2.10 (5.3.4) Joints and junctions effectively insulated 2.10 (5.3.5) Strain on internal wiring 2.10 (5.3.6) Wire carriers 2.10 (5.3.7) Wire ends not tinned Wire ends tinned: no cold flow age 14 of 45 Report o.: BCT13GR-1275S
16 E (8) ROTECTIO AGAIST ELECTRIC SHOCK 2.11 (8.2.1) Live parts not accessible Basic insulated parts not used on the outer surface without appropriate protection rotection in any position Double-ended tungsten filament lamp Insulation lacquer not reliable Double-ended high pressure discharge lamp Relevant warning according to fitted to the luminaire 2.11 (8.2.2) ortable luminaire adjusted in most unfavourable position 2.11 (8.2.3) Class II luminaire: - basic insulated metal parts not accessible during starter or lamp replacement - basic insulation not accessible other than during starter or lamp replacement - glass protective shields not used as supplementary insulation Class I luminaire with BC lampholder 2.11 (8.2.4) ortable luminaire: - protection independent of supporting surface - terminal block completely covered 2.11 (8.2.5) Compliance with the standard test finger or relevant probe 2.11 (8.2.6) Covers reliably secured 2.11 (8.2.7) Discharging of capacitors 0,5 μf ortable plug connected luminaire with capacitor Other plug connected luminaire with capacitor Discharge device on or within capacitor Discharge device mounted separately 2.12 (12) EDURACE TEST AD THERMAL TEST 2.12 (12.3) Endurance test: - mounting-position... : ormal mounting - test temperature ( C)... : 35 age 15 of 45 Report o.: BCT13GR-1275S
17 E total duration (h)... : 240h - supply voltage: Un factor; calculated voltage (V) : 264V - lamp used... : LED 2.12 (12.3.2) After endurance test: -- - no part unserviceable - luminaire not unsafe - no damage to track system - marking legible - no cracks, deformation etc (12.4) Thermal test (normal operation) (see Annex 2) 2.12 (12.5) Thermal test (abnormal operation) (see Annex 2) 2.12 (12.6) Thermal test (failed lamp control gear condition): 2.12 (12.6.1) Through wiring or looping-in wiring loaded by a current of (A)... : - case of abnormal conditions... : - electronic lamp control gear - measured winding temperature ( C): at 1,1 Un. : - measured mounting surface temperature ( C) at 1,1 Un... : - calculated mounting surface temperature ( C).. : - track-mounted luminaires 2.12 (12.6.2) Temperature sensing control - case of abnormal conditions... : - thermal link - manual reset cut-out - auto reset cut-out - measured mounting surface temperature ( C)... : - track-mounted luminaires 2.12 (12.7) Thermal test (failed lamp control gear in plastic luminaires): 2.12 (12.7.1) Luminaire without temperature sensing control 2.12 ( ) Luminaire with fluorescent lamp 70W Test method or Annex V... : Test according to : age 16 of 45 Report o.: BCT13GR-1275S
18 E case of abnormal conditions - Ballast failure at supply voltage (V)... : - Components retained in place after the test - Test with standard test finger after the test Test according to Annex V: - case of abnormal conditions - measured winding temperature ( C): at 1,1 Un.. : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : 2.12 ( ) Luminaire with discharge lamp, fluorescent lamp > 70W, transformer > 10 VA - case of abnormal conditions - measured winding temperature ( C): at 1,1 Un.. : - measured temperature of fixing point/exposed part ( C): at 1,1 Un... : - calculated temperature of fixing point/exposed part ( C)... : Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : 2.12 ( ) Luminaire with short circuit proof transformers 10 VA - case of abnormal conditions - Components retained in place after the test - Test with standard test finger after the test 2.12 (12.7.2) Luminaire with temperature sensing control - thermal link Yes o - manual reset cut-out Yes o - auto reset cut-out Yes o - case of abnormal conditions age 17 of 45 Report o.: BCT13GR-1275S
19 E highest measured temperature of fixing point/exposed part ( C):... : Ball-pressure test: - part tested; temperature ( C)... : - part tested; temperature ( C)... : 2.13 (9) RESISTACE TO DUST, SOLID OBJECTS AD MOISTURE 2.13 (9.2) Tests for ingress of dust, solid objects and moisture: - classification according to I... : I20 - mounting position during test... : - fixing screws tightened; torque (m)... : - tests according to clauses... : - electric strength test afterwards a) no deposit in dust-proof luminaire b) no talcum in dust-tight luminaire c) no trace of water on current-carrying parts or where it could become a hazard d) i) For luminaires without drain holes no water entry d) ii) For luminaires with drain holes no hazardous water entry e) no water in watertight luminaire f) no contact with live parts (I 2X) f) no entry into enclosure (I 3X and I 4X) f) no contact with live parts (I3X and I4X) 2.13 (9.3) Humidity test 48 h 25, 93% for 48 hours 2.14 (10) ISULATIO RESISTACE AD ELECTRIC STREGTH 2.14 (10.2.1) Insulation resistance test Cable or cord covered by metal foil or replaced by a metal rod of mm Ø... : Insulation resistance (MΩ) SELV: -- - between current-carrying parts of different polarity... : 100 MΩ age 18 of 45 Report o.: BCT13GR-1275S
20 E between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : 100 MΩ 100 MΩ Other than SELV: -- - between live parts of different polarity... : 100 MΩ - between live parts and mounting surface... : 100 MΩ - between live parts and metal parts... : 100 MΩ - between live parts of different polarity through action of a switch... : o switch used 2.14 (10.2.2) Electric strength test Dummy lamp Luminaires with ignitors after 24 h test Luminaires with manual ignitors Test voltage (V): SELV: -- - between current-carrying parts of different polarity... : - between current-carrying parts and mounting surface... : - between current-carrying parts and metal parts of the luminaire... : Other than SELV: 500VDC 500VDC 500VDC - between live parts of different polarity... : 1480VAC - between live parts and mounting surface... : 2960VAC - between live parts and metal parts... : 2960VAC - between live parts of different polarity through action of a switch... : 2.14 (10.3) Leakage current (ma)... : Class II luminaire, 0.05 ma, limited: 0.7 ma 2.15 (13) RESISTACE TO HEAT, FIRE AD TRACKIG 2.15 (13.2.1) Ball-pressure test: - part tested; temperature ( C)... : Transformer bobbin; 125 C - part tested; temperature ( C)... : CB; 125 C age 19 of 45 Report o.: BCT13GR-1275S
21 E part tested; temperature ( C)... : lastic enclosure of LED driver: 125 C - part tested; temperature ( C)... : Edge plastic: 75 C 2.15 (13.3.1) eedle flame test (10 s): - part tested... : CB, transformer bobbin, lastic enclosure of LED drive 2.15 (13.3.2) Glow-wire test (650 C): - part tested... : Edge plastic - part tested... : 2.15 (13.4.1) Tracking test: part tested... : age 20 of 45 Report o.: BCT13GR-1275S
22 E AEX 1: components object/part o. manufacturer/ trademark type/model technical data mark(s) of conformity Internal wire (various) (various) 20AWG, VW-1, 105 UL Fuse (various) (various) T3.15A; 250VAC VDE CB (various) (various) V-0, 130 UL Transformer (T1) (various) (various) Class B, 130 Test with appliance - rimary winding Shenzhen City Chengwei Industry Co., Ltd. -Secondary winding (TIW) - Bobbin of transformer Furukawa Electric Co., Ltd. Chang Chun lastics Co., Ltd. - Insulated tape Suzhou Mailaduona Electric Material Co., Ltd. - Varnish Hang Cheung etrochemical Ltd. lastic enclosure of LED drive 2UEW olyurethane; 130 C UL E TEX-E reinforced insulation, 130 C VDE 6735 T375J MC; V-0; 150 o C UL E59481 JY C UL E (a) 155 C UL E (various) (various) V-0, 130 UL Edge plastic (various) (various) V-0, 130 UL age 21 of 45 Report o.: BCT13GR-1275S
23 E AEX 2: temperature measurements, thermal tests of Section 12 Type reference... : CL-TA02526CBAB Lamp used... : LED Lamp control gear used... : Integral controlgear Mounting position of luminaire... : Built-in Supply wattage (W)... : 25W Supply current (A)... : -- Calculated power factor... : -- Table: measured temperatures corrected for ta = 25 C: - abnormal operating mode... : -- - test 1: rated voltage... : -- - test 2: 1,06 times rated voltage or 1,05 times rated wattage... : - test 3: Load on wiring to socket-outlet, 1,06 times voltage or 1,05 times wattage... : - test 4: 1,1 times rated voltage or 1,05 times rated wattage... : Through wiring or looping-in wiring loaded by a current of A during the test... : age 22 of X 1.06=254.4V temperature ( C) of part Clause 12.4 normal Clause 12.5 abnormal test 1 test 2 test 3 limit test 4 limit Input wire Output wire RT C CB near T T1 wire T1 core lastic enclosure of LED driver Enclosure LED surface Ref LED cover Ambient Ref Report o.: BCT13GR-1275S
24 E AEX 3: screw terminals (part of the luminaire) (14) SCREW TERMIALS (14.2) Type of terminal... : Rated current (A)... : ( ) One or more conductors ( ) Special preparation ( ) Terminal size Cross-sectional area (mm²)... : (14.3.3) Conductor space (mm)... : (14.4) Mechanical tests (14.4.1) Minimum distance (14.4.2) Cannot slip out (14.4.3) Special preparation (14.4.4) ominal diameter of thread (metric ISO thread). : External wiring o soft metal (14.4.5) Corrosion (14.4.6) ominal diameter of thread (mm)... : Torque (m)... : (14.4.7) Between metal surfaces Lug terminal Mantle terminal ull test; pull ()... : (14.4.8) Without undue damage age 23 of 45 Report o.: BCT13GR-1275S
25 E AEX 4: screwless terminals (part of the luminaire) (15) SCREWLESS TERMIALS (15.2) Type of terminal... : Rated current (A)... : (15.3.1) Material (15.3.2) Clamping (15.3.3) Stop (15.3.4) Unprepared conductors (15.3.5) ressure on insulating material (15.3.6) Clear connection method (15.3.7) Clamping independently (15.3.8) Fixed in position ( ) Conductor size Type of conductor (15.5.1) Terminals internal wiring ( ) ull test spring-type terminals (4, 4 samples).: ( ) ull test pin or tab terminals (4, 4 samples) : Insertion force not exceeding 50 (15.5.2) ermanent connections: pull-off test (20 ) (15.6) Electrical tests Voltage drop (mv) after 1 h (4 samples)... : Voltage drop of two inseparable joints umber of cycles... : Voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : Voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : After ageing, voltage drop (mv) after 10th alt. 25th cycle (4 samples)... : After ageing, voltage drop (mv) after 50th alt. 100th cycle (4 samples)... : (15.7) Terminals external wiring Terminal size and rating age 24 of 45 Report o.: BCT13GR-1275S
26 E (15.8.1) ull test spring-type terminals or welded connections (4 samples); pull ()... : ull test pin or tab terminals (4 samples); pull ()... : (15.9) Contact resistance test Voltage drop (mv) after 1 h terminal voltage drop (mv) Voltage drop of two inseparable joints Voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 10th alt. 25th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) Continued ageing: voltage drop after 50th alt. 100th cycle Max. allowed voltage drop (mv)... : terminal voltage drop (mv) age 25 of 45 Report o.: BCT13GR-1275S
27 E AEX 5: ational Differences for (country name) or Group Differences CEELEC COMMO MODIFICATIOS (E) 1.5 (3) MARKIG 1.5 ( ) Adequate warning on the package 1.10 (5) EXTERAL AD ITERAL WIRIG 1.10 (5.2.1) Connecting leads - without a means for connection to the supply - terminal block specified - relevant information provided - compliance with 4.6, 4.7.1, 4.7.2, , 11.2, 12 and 13.2 of art (5.2.2) Cables equal to HD21 S2 or HD22 S2 ZB AEX ZB, SECIAL ATIOAL CODITIOS (E) (3.3) DK: power supply cord with label IT: warning label on Class 0 luminaire (4.5.1) DK: socket-outlets (5.2.1) CY, DK, FI, SE, GB: type of plug ZC AEX ZC, ATIOAL DEVIATIOS (E) (4 & 5) FR: Shuttered socket-outlets 10/16A (13.3) DK: eedle flame test during 30 s (13.3) GB: Requirements according to United Kingdom Building Regulation (13.3.2) FR: Glow-wire test 850 C alt. 750 C for luminaires in premises open to public or 960 C for luminaires in emergency exits age 26 of 45 Report o.: BCT13GR-1275S
28 Attachment o. 1 E (4) CLASSIFICATIO Compliance of independent controlgear enclosure with E Independent SELV controlgear comply with Annex I (see Annex I) 6 (6) CLASSIFICATIO Independent controlgear...: Yes o Built-in controlgear...: Yes o Integral controlgear...: Yes o SELV-equivalent or isolating controlgear...: Yes o Auto-wound controlgear...: Yes o Independent SELV controlgear...: Yes o 7 MARKIG Requirements not applicable to be evaluated product 8 (10) ROTECTIO AGAIST ACCIDETAL COTACT WITH LIVE ARTS -(10.1) Controlgear protected against accidental contact with live parts - (A2) The current flowing between the part concerned and earth is measured and does not exceed 0,7 ma (peak) or 2 ma d.c.... : - (A2) For frequencies above 1 khz, the current does not exceed 0,7 ma (peak) multiplied by the value of the frequency in kilohertz or 70 ma (peak)... : - (A3) The voltage between the part concerned and any accessible part is measured and does not exceed 34 V (peak)... : - (10.1) Lacquer or enamel not used for protection or insulation Adequate mechanical strength on parts providing protection - (10.2) Capacitors > 0,5 F: voltage after 1 min (V):< 50 V : 8.1 (-) SELV-equivalent controlgear accessible parts are insulated from live parts by double or reinforced insulation according 8.6 and 13.1 in IEC (-) Exposed terminals of SELV or SELV-equivalent controlgear are allowed if: - the rated or maximum output voltage does not exceeding 25 V r.m.s. - the no-load output voltage does not exceed 30 V r.m.s. or 33 _2 V peak age 28 of 45 Report o.: BCT13GR-1275S
29 Attachment o. 1 E Insulated terminals if rated output voltage >25 V One capacitor Y1 or two capacitors Y2 complying with IEC of the same values used in series between SELV or SELV-equivalent output and primary circuits Other components bridging the separating transformer complying with IEC 60065, clause 14 One approved Y1 capacitor used 9 (8) TERMIALS Requirements not applicable to be evaluated product 10 (9) ROVISIO FOR EARTHIG Requirements not applicable to be evaluated product 11 (11) MOISTURE RESISTACE AD ISULATIO After storage 48 h at 91-95% relative humidity and C measuring of insulation resistance with d.c. 500 V (MΩ): 2 MΩ for basic insulation >100 MΩ 4 MΩ for double or reinforced insulation >100 MΩ 11 (-) Adequate insulation between input and output terminals not bounded together in SELV-equivalent controlgear 12 (12) ELECTRIC STREGTH Immediately after clause 11 electric strength test for 1 min Working voltage 42 V, test voltage 500 V Working voltage > 42 V 1000 V, test voltage (V): Basic insulation, 2U V Supplementary insulation, 2U V Double or reinforced insulation, 4U V Input to output: 4x =3710V o flashover or breakdown o breakdown Windings in separating transformers in SELVequivalent control gear according to of E (13) THERMAL EDURACE FOR WIDIGS (ot applicable) Requirements not applicable to be evaluated product age 29 of 45 Report o.: BCT13GR-1275S
30 Attachment o. 1 E (14) FAULT CODITIOS When operated under fault conditions the controlgear: - does not emit flames or molten material - does not produce flammable gases - protection against accidental contact not impaired Thermally protected controlgear does not exceed the marked temperature value Fault conditions: capacitors, resistors or inductors without proof of compliance with relevant specifications have been short-circuited or disconnected - (14.1) Short-circuit of creepage distances and clearances if less than specified in clause 16 in art 1 (except between live parts and accessible metal parts) Distances on printed boards provided with coating according to IEC (14.2) Short-circuit or interruption of semiconductor devices - (14.3) Short-circuit across insulation consisting of lacquer, enamel or textile (see appended table) (see appended table) (see appended table) (see appended table) - (14.4) Short-circuit across electrolytic capacitors (see appended table) - (14.5) During the tests, a five-layer tissue paper, where the test specimen is wrapped, does not ignite After the tests the insulation resistance with d.c. 500 V (MΩ) are 1 MΩ... : Temperature declared thermally protected controlgear fulfil the requirements in Annex C 15 TRASFORMER HEATIG Requirements not applicable to be evaluated product 16 ABORMAL CODITIOS Requirements not applicable to be evaluated product 17 (15) COSTRUCTIO Socket-outlet in the output circuit does not accept plugs complying with IEC and IEC o such socket-outlet age 30 of 45 Report o.: BCT13GR-1275S
31 Attachment o. 1 E ot possible to engage plugs accepted by socketoutlet in the output circuit with socket-outlets complying with IEC and IEC (15.1) Wood, cotton, silk, paper and similar fibrous material not use as insulation - (15.2) rinted boards used as internal connections complies with clause 14 of IEC (16) CREEAGE DISTACES AD CLEARACES Creepage distances and clearances according to Table 3 and 4, as appropriate rinted boards see clause 14 of IEC Insulating lining of metallic enclosures (see appended table) 19 (17) SCREWS, CURRET-CARRYIG ARTS AD COECTIOS Screws, current-carrying parts and connections in compliance with IEC (clause numbers between parentheses refer to IEC ) 20 (18) RESISTACE TO HEAT, FIRE AD TRACKIG (18.1) arts of insulating material retaining live parts in position, ball-pressure test: - part; test temperature ( C)... : Transformer bobbin; 125 C - part; test temperature ( C)... : CB; 125 C - part; test temperature ( C)... : lastic enclosure of LED driver; 125 C - part; test temperature ( C)... : Edge plastic: 75 C (18.2) rinted boards in accordance with IEC , 4.3 (18.3) External parts of insulating material preventing electric shock glow-wire test 650 C Edge plastic (18.4) arts of insulating material retaining live parts in position, needle-flame test 10 s: - flame extinguished within 30 s CB, transformer bobbin, lastic enclosure of LED driver - no flaming drops igniting tissue paper (18.5) Tracking test 21 (19) RESISTACE TO CORROSIO Requirements not applicable to be evaluated product age 31 of 45 Report o.: BCT13GR-1275S
32 Attachment o. 1 E (20) O-LOAD OUTUT VOLTAGE Requirements not applicable to be evaluated product 14 TABLE: tests of fault conditions art Simulated fault Result (fuse, components, power changed, output, smoke, gases, shut down) Output +,- s-c Input shutdown immediately, can recoverable o R5 s-c ormal working o R11 s-c ormal working o C8 s-c Input shutdown immediately, can recoverable o T1(SEC) s-c Input shutdown immediately, R27 damage, unrecoverable o D6 s-c Input shutdown immediately, fuse open, unrecoverable o Q1 (e-b) s-c Input shutdown immediately, fuse open, unrecoverable o Q1 (e-c) s-c Input shutdown immediately, fuse open, unrecoverable o Q1 (c-b) s-c Input shutdown immediately, can recoverable o D1 s-c Input shutdown immediately, fuse open, unrecoverable o s-c: short-circuit o-c: open-circuit Hazard 18 (16) TABLE: clearance and creepage distance measurements Minimum distances for a.c. (50/60 Hz) sinusoidal voltages -- RMS working voltage (V) not exceeding ) minimum distances between live parts of different polarity. Specify the value measured. 2) minimum distances between live parts and >7.0 accessible parts which are permanently fixed to the ballast, including screws or devices for fixing covers or fixing the ballast to its support. Specify the value measured. 3) minimum distances for ballasts declared protected against accidental contact between live parts and the outer accessible surface of insulating parts - required creepage distances (mm), Basic insulation TI 600 0,6 1,4 1, ,5 - required creepage distances (mm), Basic 1,2 1,6 2, insulation TI < required creepage distances (mm), Supplementary insulation TI 600 1,4 1, ,5 - required creepage distances (mm), Supplementary insulation TI < 600 1,6 2, age 32 of 45 Report o.: BCT13GR-1275S >2.7
33 Attachment o. 1 E required creepage distances (mm), Reinforced insulation required clearances (mm) Basic insulation 0,2 1,4 1, ,5 - required clearances (mm) reinforced insulation 0,2 1,4 3, ,5 3) minimum distances between live parts and a flat supporting surface or a loose metal cover, if any, if the construction does not ensure that the values under 2 above are maintained under the most unfavourable circumstances - required clearances (mm) 2 3,2 3,6 4,8 6 8 Minimum distances for non-sinusoidal pulse voltages rated pulse voltage (peak kv) 2,0 2,5 3,0 4,0 5,0 6,0 8,0 required minimum distances, clearances (mm) Specify the value measured >5.0 1,0 1, ,5 8 rated pulse voltage (peak kv) required minimum distances, clearances (mm) Specify the value measured rated pulse voltage (peak kv) required minimum distances, clearances (mm) Specify the value measured age 33 of 45 Report o.: BCT13GR-1275S
34 Attachment o. 1 IEC A AEX A, TEST TO ESTABLISH WHETHER A CODUCTIVE ART IS A LIVE ART WHICH MAY CAUSE A ELECTRIC SHOCK Requirements not applicable to be evaluated product C AEX C ARTICULAR REQUIREMETS FOR ELECTROIC LAM COTROLGEAR WITH MEAS OF ROTECTIO AGAIST OVERHEATIG Requirements not applicable to be evaluated product E AEX E USE OF COSTAT S OTHER THA 4500 I t w TESTS Requirements not applicable to be evaluated product F AEX F - DRAUGHT-ROOF ECLOSURE Draught-proof enclosure in accordance with the description Dimensions of the enclosure Other design; description H AEX H - TESTS All tests performed in accordance with the advise given in Annex H, if applicable I AEX I - articular additional requirements for independent SELV d.c. or a.c. supplied electronic controlgear for LED modules Requirements not applicable to be evaluated product age 34 of 45 Report o.: BCT13GR-1275S
35 Attachment o. 2 E GEERAL REQUIREMETS 4.4 Integral modules treated as part of luminaires defined in clause 0.5 of IEC Independent modules complies with requirements in IEC Complying with requirements in IEC GEERAL TEST REQUIREMETS 5.5 SELV-operated LED modules comply with Annex I of IEC (see Annex B) 6 CLASSIFICATIO Built-in module...: Yes o Independent module...: Yes o Integral module...: Yes o For Integral module; ote to in IEC applies. 7 MARKIG 7.1 Mandatory markings: - mark of origin - model number, type reference... : - rated supply voltage (V)... : - rated supply current (A)... : - rated input power (V)... : - nominal power - indication of connections, wiring diagram - value of t c - eye protection - marking of built-in modules only location of marking 7.3 Marking durable and legible Rubbing 15 s water, marking legible 8 SCREW TERMIALS age 35 of 45 Report o.: BCT13GR-1275S
36 Attachment o. 2 E Compliance with section 14 of IEC SCREWLESS TERMIALS Compliance with section 15 of IEC COECTORS Compliance with IEC ROVISIO FOR ROTECTIVE EARTHIG External metal parts connected to the earth terminal: - compliance with in IEC Test with a current of 10 A between earthing terminal and each of the accessible metal parts; measured resistance (Ω): < 0,5 Ω...: rotective earth, symbol Terminal complying with clause 8 in art 1 Locked against loosening and not possible to loosen by hand ot possible to loosen clamping means unintentionally on screwless terminals Earthing via means of fixing Earthing terminal only used for the earthing of the control gear All parts of material minimizing the danger of electrolytic corrosion Made of brass or equivalent material Contact surface bare metal Conductors by tracks on printed circuit boards: - a.c. current of 25 A for 1 min between earthing terminal and accessible metal parts - compliance with clause in IEC (10) ROTECTIO AGAIST ACCIDETAL COTACT WITH LIVE ARTS rotection against accidental contact with live parts in compliance with IEC (clause numbers between parentheses refer to IEC ) - (10.1) Controlgear protected against accidental contact with live parts - (A1) Current measured according to IEC 60990, figure age 36 of 45 Report o.: BCT13GR-1275S
37 Attachment o. 2 E and clause 7.1: max. 0,7 ma (peak) or 2,0 ma d.c., for f 1000 Hz max. 70 ma... : - (A2) Voltage at 50 kω (V): max. 34 V (peak)... : Lacquer or enamel not used for protection or insulation Adequate mechanical strength on parts providing protection - (10.2) Capacitors > 0,5 μf: voltage after 1 min (V): < 50 V... : 8.1 (-) SELV-equivalent controlgear accessible parts are insulated from live parts by double or reinforced insulation according 8.6 and 13.1 in IEC (-) Exposed terminals of SELV or SELV-equivalent controlgear are allowed if: - the rated or maximum output voltage does not exceeding 25 V r.m.s. - the no-load output voltage does not exceed 30 V r.m.s. or 33 2 V peak Insulated terminals if rated output voltage >25 V One capacitor Y1 or two capacitors Y2 of the same values used in series between SELV or SELV-equivalent output and primary circuits - Capacitor complying with IEC Other components bridging the separating transformer complying with E 60065, clause MOISTURE RESISTACE AD ISULATIO rotection against moisture and insulation in compliance with Clause 11, IEC After storage 48 h at 91-95% relative humidity and C measuring of insulation resistance with d.c. 500 V (MΩ): 2 MΩ... : Adequate insulation between input and output terminals not bounded together in SELVequivalent controlgear For double or reinforced insulation the resistance exceeds 4 MΩ 100 MΩ age 37 of 45 Report o.: BCT13GR-1275S
38 Attachment o. 2 E ELECTRIC STREGTH Electric strength in compliance with Clause 12 of IEC Immediately after clause 11 electric strength test for 1 min Working voltage 42 V, test voltage 500 V 500V Working voltage > 42 V, test voltage (V): 2U V... : Reinforced insulation, test voltage (V):... : o flashover or breakdown Windings in separating transformers in SELVequivalent control gear according to of E FAULT CODITIOS 13.1 In compliance with IEC (clause numbers between parentheses refer to IEC ) When operated under fault conditions the LED-module: - does not emit flames or molten material - does not produce flammable gases - protection against accidental contact not impaired Thermally protected controlgear does not exceed the marked temperature value Fault conditions: capacitors, resistors or inductors without proof of compliance with relevant specifications have been short-circuited or disconnected - (14.1) Short-circuit of creepage distances and clearances if less than specified in clause 16 in art 1 (except between live parts and accessible metal parts) Distances on printed boards provided with coating according to IEC (14.2) Short-circuit or interruption of semiconductor devices - (14.3) Short-circuit across insulation consisting of lacquer, enamel or textile (see appended table) (see appended table) (see appended table) (see appended table) - (14.4) Short-circuit across electrolytic capacitors (see appended table) - (14.5) During the tests, a five-layer tissue paper, where age 38 of 45 Report o.: BCT13GR-1275S
39 Attachment o. 2 E the test specimen is wrapped, does not ignite After the tests the insulation resistance with d.c. 500 V (MΩ) are 1 MΩ...: Temperature declared thermally protected LEDmodules fulfil the requirements in Annex C of IEC Module withstands overpower condition >15 min. Module with automatic protective device or power limiter, test performed 15 min. at limit. During the tests, tissue paper, spread below module, does not ignite 15 COSTRUCTIO Wood, cotton, silk, paper and similar fibrous material not used as insulation 16 CREEAGE DISTACES AD CLEARACES Creepage and distances and clearances in compliance with IEC Class of protection... : Working voltage (V)... : Voltage form... : on-sinusoidal TI... : < 600 Rated pulse voltage (kv)... : -- (1) Live parts of different polarity: cr (mm); cl (mm)... : (2) Live parts and accessible parts: cr (mm); cl (mm)... : (3) arts becoming live: cr (mm); cl (mm)... : (4) Outer surface of cable: cr (mm); cl (mm)... : (5) Live parts of switches: cr (mm); cl (mm)... : (6) Live parts and supporting surface: cr (mm); cl (mm)... : 17 (17) SCREWS, CURRET-CARRYIG ARTS AD COECTIOS Screws, current-carrying parts and connections in compliance with IEC (clause numbers between parentheses refer to IEC ) age 39 of 45 Report o.: BCT13GR-1275S
40 Attachment o. 2 E (4.11) Electrical connections: (4.11.1) Contact pressure (4.11.2) Screws: - self-tapping screws - thread-cutting screws - at least two self-tapping screws (4.11.3) Screw locking: (4.11.4) Material of current-carrying parts (4.11.5) o contact to wood (4.12) Mechanical connections and glands: (4.12.1) Mechanical stress Screws not made of soft metal Screws of insulating material Torque test: part; torque (m)... : Torque test: part; torque (m)... : Torque test: part; torque (m)... : (4.12.2) Screw diameter < 3 mm screwed into metal (4.12.3) Void (4.12.4) Locked connections (4.12.5) Screwed glands: force ()... : 18 (18) RESISTACE TO HEAT, FIRE AD TRACKIG Resistance to Heat, Fire and Tracking in compliance with IEC (clause numbers between parentheses refer to IEC ) (18.1) arts of insulating material retaining live parts in position, ball-pressure test: - part; test temperature ( C)... : Transformer bobbin; 125 C - part; test temperature ( C)... : CB; 125 C - part; test temperature ( C) : lastic enclosure of LED driver; 125 C - part tested; temperature ( C)... : Edge plastic: 75 C (18.2) rinted boards in accordance with IEC , 4.3 (18.3) External parts of insulating material preventing electric shock glow-wire test 650 C age 40 of 45 Edge plastic Report o.: BCT13GR-1275S
41 Attachment o. 2 E (18.4) arts of insulating material retaining live parts in position, needle-flame test 10 s: - flame extinguished within 30 s CB, Transformer bobbin, lastic enclosure of LED driver - no flaming drops igniting tissue paper (18.5) Tracking test 19 RESISTACE TO CORROSIO Resistance to corrosion in compliance with IEC Rust protection: - test according of IEC adequate varnish on the outer surface A AEX A - TESTS All tests performed in accordance with the advise given in Annex H of IEC , if applicable B AEX B - SELV-operated LED modules Requirements not applicable to the evaluated products. age 41 of 45 Report o.: BCT13GR-1275S
42 Appendix 3 hoto documentation hoto 1 Whole View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal hoto 2 Whole View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal age 42 of 45 Report o.: BCT13GR-1275S
43 hoto 3 View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal hoto 4 LED Driver View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal age 43 of 45 Report o.: BCT13GR-1275S
44 hoto 5 View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal hoto 6 View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal age 44 of 45 Report o.: BCT13GR-1275S
45 hoto 7 View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal hoto 8 View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal age 45 of 45 Report o.: BCT13GR-1275S
46 hoto 9 View: [ ] top [ ] front [ ] rear [ ] right side [ ] left side [ ] bottom [ ] internal ---End of test report--- age 46 of 45 Report o.: BCT13GR-1275S
Shenzhen BST Technology Co., Ltd. LEDz Shine LVD REPORT. 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa
Report o.: BST13080325Y-1SR-2 LEDz Shine LVD REORT repared For: LEDz Shine 98 Cormorant,Jakkalsfontein,Darling 7345,South Africa roduct ame: LED FLOOD LIGHT Trade: LEDz Shine 100W, LEDz Shine 10W, LEDz
More informationLVD TEST REPORT. For LED TUBE. Model: T10, T8, T5. Reference No.: CE10-LIE040101S
Ref. o.: CE10-LIE040101S LVD TEST REORT For LED TUBE Model: T10, T8, T5 Reference o.: CE10-LIE040101S Issued by: Shenzhen EBO Testing Center Lab location: Yihua Building, Shennan Road, Futian District,
More informationReport o.: USG R-L TEST REORT E60950 Electric Skateboard art 1: General requirements and tests Testing Laboratory ame...: Shenzhen USG Techno
Report o.: USG2015101902R-L Koofy Development Limited. LVD REORT repared For : Shenzhen Song Chen Da Technology Co., Ltd 4th floor, o. 6, Xishan Road, Longteng Community, Shiyan, Shenzhen, China roduct
More informationLuminaire for road and street lighting. Approved by / Authorized Signatory:
Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test
More informationShenzhen Toby Technology Co., Ltd. LVD Test Report. Application No. : TB Applicant : BREE LIGHTING Co., LIMITED. Equipment Under Test (EUT)
Shenzhen Toby Technology Co., Ltd. LVD Test Report age: 1 of 33 Application o. : TB13035196 Applicant : BREE LIGHTIG Co., LIMITED Equipment Under Test (EUT) EUT ame : Led Flood Light Model o. : BR-FL-10W-01-IR
More informationTest Report issued under the responsibility of:
age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in
More informationTest Report issued under the responsibility of:
age 1 of 30 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT Luminaires art 2: articular requirements: Section Six Luminaires with built-in
More informationPage 3 of 34 Report No Part I
www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are
More informationTEST REPORT IEC and/or EN Luminaires Part 1: General Requirements And Tests
Test Report issued under the responsibility of: Report Reference o...: age 1 of 11 TEST REORT IEC 60968 and/or E 60968 Luminaires art 1: General Requirements And Tests GTSS12060031301 Date of issue...:
More informationEN : MEASUREMENT AND TEST REPORT For
E 60598-1: 2004 MEASUREMET AD TEST REORT For LOGSTAR LIGHTIG GROU TangTou Industry park, ShiYan Town, BaoAn district, Shenzhen City, Guangdong rovince, China Model:LS-T8-T600S1,LS-T8-T900S1,LS-T8-T1200S1,LS-T8-T1500S1,LS-T8-M600S1,
More informationTEST REPORT. EN Luminaires Part 2: Particular requirements Section 21: Rope Lights
TEST REORT EN 60598-2-21 Luminaires art 2: articular requirements Section 21: Rope Lights Report reference No.... : ED170727001S Tested by... : Coral Chen Approved by... : Kobe Mai Date of issue... : August
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires
TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements Section 1: Fixed general purpose luminaires Report Number.... : 64.140.11.02922.03 Date of issue... : 2015-02-02 Total number of pages...
More informationCompliance Testing Report for Australian/New Zealand Standard AS/NZS : 2014 Inc Amendment 1 in conjunction with AS/NZS60598.
Doc Id: AS/ZS60598.2.1:2014+A1 Report o: 0803BSS-61900_59821 age 1 of 49 Compliance Testing Report for Australian/ew Zealand Standard AS/ZS 60598.2.1: 2014 Inc Amendment 1 in conjunction with AS/ZS60598.1:2013
More informationSAA TEST REPORT On Behalf of : AOK LED LIGHT COMPANY LIMITED
age 1 of 47 Report o. R011501451I SAA TEST REORT On Behalf of AOK LED LIGHT COMAY LIMITED LED Street Light Model: AOK-30WiL, AOK-40WiL, AOK-60WiL, AOK-80WiL, AOK-90WiL, AOK-120WiL, AOK-160WiL, AOK-150WiL,
More informationPage 1 of 27 Report No. : HT15DR LVD Test Report
age 1 of 27 LVD Test Report EN60598-1&EN60598-2-1 art 1:General requirement and tests art 2: articular requirments Section One Fixed general purpose luminaires Report reference No.......: HT15DR-120321
More informationCENTRE OF TESTING SERVICE INTERNATIONAL
CETRE OF TESTIG SERVICE ITERATIOAL OERATE ACCORDIG TO ISO/IEC 17025 LVD TEST REORT TEST REORT UMBER : CGZ3150109-00114-L-F GZ test site: A101, o.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China
More informationTEST REPORT EN LED modules for general lighting Safety specifications
TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section Two Recessed luminaires Report Reference No...: 3117604.50A Date of issue...: 2011-05-26 Total
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No... : 2170798.50 Date of issue... :
More informationShenzhen Merrylux Optoelectronics co., ltd TEST REPORT. Building A, Wenfu Area, No. 1 Industry Park Fenghuang, Fuyong,Baoan, Shenzhen, China,
Shenzhen BST Technology Co., Ltd Shenzhen Merrylux Optoelectronics co., ltd TEST REORT repared For: Shenzhen Merrylux Optoelectronics co., ltd Building A, Wenfu Area, o. 1 Industry ark Fenghuang, Fuyong,Baoan,
More informationTEST REPORT EN : 1996 LUMINAIRES --- SAFETY--- PART 2-2: Particular requirements- Recessed luminaires
Test Report issued under the responsibility of: TEST REORT E 60598-2-2: 1996 LUMIAIRES --- SAFETY--- ART 2-2: articular requirements- Recessed luminaires Report reference o...: GTSS12080044101 Compiled
More informationTEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules
age 1 of 40 Test Report issued under the responsibility of: Intertek Testing Services Shenzhen Ltd. Guangzhou Branch TEST REORT art 2: articular requirements: Section Thirteen d.c. or a.c. supplied electronic
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section Three Luminaires for road and street lighting
Test Report issued under the responsibility of www.nemko.com TEST REORT Luminaires art 2: articular requirements: Section Three Luminaires for road and street lighting Report Reference No...: 154909 Date
More informationTEST REPORT EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
TEST REORT EN 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No...: 3007562.50-QUA/LI Date of issue...: 2011-03-28 Total number of pages...
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
Test Report issued under the responsibility of: TEST REORT IEC 60598-2-1 Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Number.... : 17041854 001 Date of
More informationTEST REPORT AS/NZS :2015 Luminaires Part 2.3: Particular requirements Luminaires for road and street lighting
TEST REORT AS/ZS 60598.2.3:2015 Luminaires art 2.3: articular requirements Luminaires for road and street lighting Report Reference o.... : RSZ170419551-03 Compiled by (+ signature)... : Andy Fu Approved
More informationSGS Australia Pty Ltd
TEST REORT Luminaires art 2.1: articular requirements Fixed general purpose luminaires Accredited for compliance with ISO/IEC 17025 Report Reference No.... : S17031 Compiled by (+ signature)... : Yongchan
More informationTEST REPORT. Luminaires Part 1: General requirements and Tests Part 2: Particular requirements - Section 4: Portable general purpose luminaires
TEST REORT Luminaires art 1: General requirements and Tests art 2: articular requirements - Section 4: ortable general purpose luminaires Report Reference o: Tested by: T1321-21-12 Urs Wyttenbach Approved
More informationTEST REPORT IEC Part 2: Particular requirements: Section 11: Miscellaneous electronic circuits used with luminaires
Test Report issued under the responsibility of: TEST REORT art 2: articular requirements: Section 11: Miscellaneous electronic circuits used with luminaires Report Number...: 2213248.50 Date of issue...:
More informationTesting Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.
11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797
More informationTEST REPORT AS/NZS Luminaires Part 2: Particular requirements: Fixed general purpose luminaires
Report Reference o....: Compiled by (+ signature)...: Approved by (+ signature)... : TEST REORT AS/ZS 60598.2.1 Luminaires art 2: articular requirements: Fixed general purpose luminaires RSZ160822550-03
More informationpage 2 of 82 IEC 60950
page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:
More informationFor. Shanghai Moons Automation Control Co., Ltd.
Shenzhen BCTC Technology Co., Ltd. Report o.: BCTC-13080904S ALICATIO FOR LVD For Shanghai Moons Automation Control Co., Ltd. roduct ame: LED drivers Trademark: Model : repared For : MU096A024A, MU096A175AQD
More informationTEST REPORT EN Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules
TEST REORT E 61347-2-13 Lamp controlgear art 2-13: articular requirements for d.c. or a.c. supplied electronic controlgear for LED modules Report umber.... : TCDQ02170721805S-LD01 Date(s) of performance
More informationSEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED
Report o.: BSTDG13050805SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan Road,
More informationAPPLICATION FOR LOW VOLTAGE DIRECTIVE On Behalf of. : Shenzhen Qinhan Lighting Co.,Ltd
age 1 of 55 Report o. R011607605S-1 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of Shenzhen Qinhan Lighting Co.,Ltd LED Flood Light Model: QH-FLXH01-50W, QH-FLXH02-100W, QH-FLXH03-150W, QH-FLXH04-200W,
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements Section 2: Recessed luminaires
age 1 of 40 TEST REORT IEC 60598-2-2 Luminaires art 2: articular requirements Section 2: Recessed luminaires Report Number.... : 7040216100405-00 Date of issue... : 2016-11-18 Total number of pages...
More informationPage 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.
12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...
More informationTEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements
TEST REORT IEC 60968 and/or EN 60968 Self-ballasted lamps for general lighting services Safety requirements Report reference No.... : 3006889.50-QUA/LI Tested by (printed name and signature)... : Cliff
More informationTEST REPORT IEC LED modules for general lighting Safety specifications
Test Report issued under the responsibility of: TEST REORT LED modules for general lighting Safety specifications Report Number...: 2173700.50 Date of issue... : 20140923 Total number of pages... 33 Applicant
More informationTEST REPORT. Prepared By: Waltek Services (Foshan) Co., Ltd.
TEST REORT Reference o.... : WTF15F0730677S Applicant... : Foshan anhai Vorld Lighting Co., Ltd. Address... : 18th west Taoyuan Road, Shishan Town, anhai District, Foshan City, Guangdong rovince Manufacturer...
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements: Section One Fixed general purpose luminaires Report Reference No....: TGM-VA EE32453 SFT Date of issue...
More informationSEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED TEST REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED
Report o.: BSTDG13050811SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED TEST REORT repared For : SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial ark,10th Shangxue Yituan
More informationCERTIFICATE of Conformity Reference No. : LCS S 001 Applicant : LOKOLED Address : Kitmanstraat PM Alkmaar The Netherlands Trademark :
CERTIFICATE of Conformity Reference o. : LCS1702161029S 001 Applicant : LOKOLED Address : Kitmanstraat 14 1812 M Alkmaar The etherlands Trademark : /A roduct : LED Downlight Model(s) : (see attached) arameters
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires
Test Report issued under the responsibility of: Studio Oleandri - Milano TEST REPORT IEC 60598-2-1 Luminaires Part 2: Particular requirements Section 1: Fixed general purpose luminaires Report Number...
More information< > Page 2 of 84
age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes
More informationL7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD
age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated
More informationRemark: Whether parts of tests for the product have been subcontracted to other labs:
Reference o.: WTS16S1166817S age 2 of 60 Test item description...: Trademark...: Model and/or type reference...: AU-BD350VA Rating(s)... : 220-240V~, 50Hz, Max. 350VA, Min 10VA Remark: Whether parts of
More informationPage 3 of 90 Report No.: List of Attachments (including a total number of pages in each attachment):
age 3 of 90 Report No.: 17052930 001 List of Attachments (including a total number of pages in each attachment): Attachment 1: 12 pages of photos. Summary of testing: Tests performed (name of test and
More informationSEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED LVD REPORT SEMLIGHT SEMICONDUCTOR LIGHTING CO., LIMITED
Shenzhen BST Technology Co., Ltd Report o.: BSTDG13050806SR-2 SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED LVD REORT repared For: SEMLIGHT SEMICODUCTOR LIGHTIG CO., LIMITED 5F, Building o.2, Yituan Industrial
More informationSCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU
age 1 of 46 Ref. o: TEST REORT IEC 60884-1:2002 (Third edition)+a1:2006 IEC 60 884-2-2:2006 lugs and socket-outlets for household and similar purposes art 1: General requirements art 2: articular requirements
More informationTEST REPORT SHENZHEN LIANHEYIDA ELECTRONIC TECHNOLOGY CO.,LTD
Report o.: BST14090471Y-1SR-2 SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD TEST REORT repared For : SHEZHE LIAHEYIDA ELECTROIC TECHOLOGY CO.,LTD 4F,Building A,YouXinDa Industrial Area, GenYu Road,TianLiao
More informationTEST REPORT IEC and/or EN Safety of household and similar electrical appliances
- age 1 of 76 - Report o. ID 2050-1A/03 TEST REORT and/or E 60335-1 Safety of household and similar electrical appliances Report Reference o....: ID 2050-1A/03 Compiled by (+ signature)...: Roberto Tarro
More informationENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue
ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE
More informationLIA Laboratories Limited
LIA Laboratories Limited Certificate of Conformity Reference LH1012J This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7607ET roduct Description(s):
More informationLVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.
LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.
More informationLIA Laboratories Limited
LIA Laboratories Limited Certificate of Conformity Reference LH1012R This is to certify that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7601E, 7602E, 7603E,
More informationTEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7
TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample
More informationThis standard covers the requirements of lighting chains. This standard covers only the safety requirements.
FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the
More informationTest Report. Apricus Solar Co., Ltd. Multi-function differential controller
Test Report Applicant: roduct: Trade mark Model No: Apricus Solar Co., Ltd. Multi-function differential controller Apricus MFC-1 repared by: Most Technology Service Co., Limited The safety testing has
More informationInstallation Couplers intended for permanent connection in fixed installation
age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....
More informationZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :
Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 1540-44-I Date of issue... : 2016-09-01
More informationTEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors
r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of
More informationTEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools
age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total
More informationTest Report No. 55S071315/ZHY/PKS dated 10 JUL 2007
Test Report No. 55S071315/ZHY/KS Note: This report is issued subject to TÜV SÜD SB's "Terms and Conditions Governing Technical Services". The terms and conditions governing the issue of this report are
More informationTEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools
age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total
More informationTest report: 13/ Date January 20 th,2014 Page 1 of 52
LGAI LGAI Technological Center, S.A. Campus de la UAB Apartado de Correos 18 E - 08193 Bellaterra (Barcelona) T +34 93 567 20 00 F +34 93 520 20 01 www.appluslaboratories.com TEST REORT Test report: 13/31705080
More informationLIA Laboratories Limited
LIA Laboratories Limited Certificate of Test Reference LH1014B This is to confirm that: S Lilley & Son Ltd 80 Alcester Street Birmingham West Midlands B12 0QE Model Reference(s): 7701E/AB123, 7702E/AB123,
More informationTEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements
TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : SH12030248-001 Date of issue... : 2012-04-28 Total number of pages 46 Testing
More informationTEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements
age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed
More informationPage 3 of 32 Report No Summary of testing:
age 3 of 32 Report No. 27121998 001 Summary of testing: Tests performed (name of test and test clause): 22 114 model is chosen as representative. Below clasues are applied to appliances: 8. Marking 9.
More informationTest report for mechanical switches according to IEC Switches for appliances Part 1: General requirements
Test Report issued under the responsibility of: Test report for mechanical switches according to Switches for appliances art 1: General requirements Report reference No.... : 4312037.50 Date of issue...
More informationTEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches
TEST REORT Switches for household and similar fixed-electrical installations art 2-1: articular requirements - Electronic switches Report Reference No.... : 102639859CRT-001a Date of issue... : 09/28/2016
More informationTEST REPORT IEC Luminaires Part 2: Particular requirements Section 3: Luminaires for road and street lighting
Test Report issued under the responsibility of: TEST REORT Luminaires art 2: articular requirements Section 3: Luminaires for road and street lighting Report Number.... : 6011995.50 Date of issue... :
More informationTEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules
age 1 of 66 Test Report issued under the responsibility of NCB: NCB TÜV SÜD SB 1 Science ark Drive, 118221 Singapore Singapore TEST REORT IEC 61347-2-13 art 2: articular requirements: Section Thirteen
More informationTEST REPORT IEC Switches for appliances Part 2-1: Particular requirements for cord switches
Test Report issued under the responsibility of: TEST REPORT Switches for appliances Part 2-1: Particular requirements for cord switches Report Reference No.... : SH11080876-001 Date of issue... : 2012-02-23
More informationTEST REPORT IEC/EN Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires
Test Report issued under the responsibility of: TEST REPORT Luminaires Part 2: Particular requirements: Section One Fixed general purpose luminaires Report Reference No...: HZ10120073-001 ate of issue...:
More informationTEST REPORT EN Household and similar electrical appliances Part 1: General requirements
TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved
More informationTEST REPORT IEC Connectors Safety requirements and tests
IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 249955-TL6-1 Date of
More informationTEST REPORT IEC Connectors Safety requirements and tests
IECEE OD-2020-F1:2017 IEC 2017 Ed.1.0 TRF Template 2017-05-17 Test Report issued under the responsibility of: TEST REORT Connectors Safety requirements and tests Report Number... : 250150-TL6-1 Date of
More informationPage 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A
Ratings...: age 2 of 41 Report o.: CTL1607012503-WS Adapter: Input: 100-240Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A age 3 of 41 Report o.: CTL1607012503-WS Summary of testing: Testing
More informationEmergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series
BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile
More informationTEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L
TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power
More informationEmergency lighting units EM converterled
BASIC MH/iFePO4 90 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile
More informationEmergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series
BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile
More informationSHA-001 Date of issue...: Total number of pages Report Reference No...:
TEST REORT lugs and socket-outlets for household and similar purposes art 2-1: General requirements on plugs and portable socket-outlets Report Reference No....: 130600884SHA-001 Date of issue...: 2013-07-09
More informationTEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements
TEST REORT lugs and socket-outlets for household and similar purposes art 1: General requirements Report Reference No.... : 70.410.14.127.01-01 Date of issue... : 2014-07-03 Total number of pages... 61
More informationTEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans
Test Report issued under the responsibility of: Report Number....: TEST REORT Safety of household and similar electrical appliances art 2 : articular requirements for fans GZ10040377-1R1 Date of issue...:
More informationAPPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82
age 1 of 25 Report o. R0617060399B ALICATIO FOR IEC REORT On Behalf of HEA ESHOW ELECTROIC COMMERCE CO., LTD Li-ion Battery Model: RT82 repared For : HEA ESHOW ELECTROIC COMMERCE CO., LTD Room 722, Sanjiang
More informationEmergency lighting units EM converterled
BASIC MH/iFePO4 250 V BASIC series Product description Self contained emergency lighting Driver for manual testing For modules with a forward voltage of 50 250 V ow profile casing (21 x 30 mm cross-section)
More informationTYPE TEST REPORT FOR. Uninterruptible Power Systems. Model: EA200N series (2000VA, 2200VA, 2500VA, 2600VA, 3000VA, 3500VA)
TYE TEST REORT FOR Uninterruptible ower Systems Model: EA200 series (2000VA, 2200VA, 2500VA, 2600VA, 3000VA, 3500VA) repared for : GUAGDOG EAST OWER CO., LTD. O.6 ORTHER IDUSTRY ROAD, SOGSHA LAKE SCI&TECH
More informationAS/NZS AS/NZS
TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total
More informationTYPE TEST REPORT FOR. Uninterruptible Power Systems. Model: EA200N series (2000VA, 2200VA, 2500VA, 2600VA, 3000VA, 3500VA)
TYE TEST REORT FOR Uninterruptible ower Systems Model: EA200 series (2000VA, 2200VA, 2500VA, 2600VA, 3000VA, 3500VA) repared for : GUAGDOG EAST OWER CO., LTD O.6 ORTHER IDUSTRY ROAD, SOGSHA LAKE SCI&TECH
More informationIntertek Testing Service Taiwan Ltd. 5F, No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan as above Recom Development & Trading GmbH & Co KG
age 1 of 38 Report No.ETS-060067 TEST REORT IEC 60601-1 / EN 60601-1 Medical electrical equipment art 1: General requirements for safety Report reference No.... : ETS-060067 Testled by (+ signature)...
More informationAnnex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.
TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex
More informationEmergency lighting units EM converterled
EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for
More informationCopy of marking plate. Page 2 of 50 Report No. TRS
Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :
More informationTEST REPORT DIN V VDE V
Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...
More informationPIL0478 ISSUE 01/ 07/16
ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW
More information