COVER PAGE FOR TEST REPORT

Size: px
Start display at page:

Download "COVER PAGE FOR TEST REPORT"

Transcription

1 Issue Date: Page 1 of 2 Report Reference # E A19-UL-1 Amendment COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Information Technology Equipment Including Electrical Business Equipment NWGQ, NWGQ7 Listing NPort IA Series Device Service 1) NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, NPort IA-5250I, NPort IA -5250I-T, MGate MB3270I, MGate EIP3270I, MGate MB3270I-T, MGate EIP3270I-T. Rating(s): 2) NPort IA-5150-S-SC, NPort IA S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate EIP3170I, MGate MB3170I-T, MGate EIP3170I-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, NPort IA- 5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I- M-SC-T. 3) NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGate EIP3170, MGate MB3170-T, MGate EIP3170-T, NPort IA-5250, NPort IA-5250-T, MGate MB3270, MGate EIP3270, MGate MB3270-T, MGate EIP3270-T. 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional) 3) Vdc, maximum 435 ma (Optional) Standards: UL , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) Applicant Name and Address: MOXA INC 4TH FL 135 LANE 235 PAO CHIAO RD SHING TIEN CITY TAIPEI 231 TAIWAN This Report includes the following parts, in addition to this cover page: 1. Specific Technical Criteria 2. Critical Components 3. Enclosures Copyright 2009

2 Issue Date: Page 2 of 2 Report Reference # E A19-UL-1 Amendment This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow -Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of ('UL') in accordance with the Follow -Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow -Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. Test Report By: Reviewed By: Jonathan Chen Associate Project Engineer Underwriters Laboratories Taiwan Co., Ltd. Jim Kao Associate Project Engineer Underwriters Laboratories Taiwan Co., Ltd. Copyright 2009

3 Issue Date: Page 1 of 8 Report Reference # E A19-UL-1 Amendment SPECIFIC TECHNICAL CRITERIA UL , First Edition Information technology equipment - Safety- Part 1: General Requirements Report Reference No... : E A19-UL-1 Compiled by... : Jonathan Chen Reviewed by... : Jim Kao Date of issue... : Standards... : UL , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure... : Listing Non-standard test method... : Test item description... : NPort IA Series Device Service Trademark... : None Model and/or type reference... : 1) NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M- SC, MGate MB3170-M-SC-T, NPort IA -5250I, NPort IA-5250I-T, MGate MB3270I, MGate EIP3270I, MGate MB3270I-T, MGate EIP3270I-T. 2) NPort IA-5150-S-SC, NPort IA S-SC-T, MGate MB3170-S- SC, MGate MB3170-S-SC-T, NPort IA -5150I, NPort IA-5150I-T, MGate MB3170I, MGate EIP3170I, MGate MB3170I-T, MGate EIP3170I-T, NPort IA -5150I-S-SC, NPort IA -5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M- SC-T. 3) NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGate EIP3170, MGate MB3170-T, MGate EIP3170-T, NPort IA-5250, NPort IA T, MGate MB3270, MGate EIP3270, MGate MB3270-T, MGate EIP3270-T. Rating(s)... : 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional) 3) Vdc, maximum 435 ma (Optional)

4 Issue Date: Page 2 of 8 Report Reference # E A19-UL-1 Amendment Particulars: test item vs. test requirements Equipment mobility...: movable Operating condition...: continuous Mains supply tolerance (%)...: No direct connection Tested for IT power systems...: No IT testing, phase-phase voltage (V)...: Class of equipment...: Class III (supplied by SELV) Mass of equipment (kg)...: 0.16 Protection against ingress of water...: IP X0 Possible test case verdicts: - test case does not apply to the test object...: N / A - test object does meet the requirement...: Pass - test object does not meet the requirement...: Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

5 Issue Date: Page 3 of 8 Report Reference # E A19-UL-1 Amendment GENERAL PRODUCT INFORMATION: CA1.0 CA1.1 Report Summary CB1.0 CB1.1 Product Description The unit was configured as follows: Consists of electronic components mounted on PWB, Fiber connector, Series connector (SR-232), SR422/485 connector or Ethernet(RJ45) connector, and housed with plastic enclosure. CC1.0 CC1.1 Model Differences All models are similar to NPort IA-5150 except for output connector type and model designation detailed as blew. Models NPort IA T, MGate MB3170 and, MGate MB3170-T, MGate EIP3170 and MGate EIP3170-T are identical to Model NPort IA except for model designation. Models NPort IA -5150I-T, MGate MB3170I and, MGate MB3170I-T, MGate EIP3170I and MGate EIP3170I-T are identical to Model NPort IA-5150I except for model designation. Models NPort IA T, MGate MB3270, and MGate MB 3270-T, MGate EIP3270, MGate EIP3270-T, NPort IA-5250I-T, MGate MB3270I, and MGate MB3270I-T, MGate EIP3270I and MGate EIP3270I-T are identical to Model NPort IA-5250 except for model designation. Models NPort IA S-SC-T, MGate MB3170-S-SC and MGate MB3170-S-SC-T are identical to Model NPort IA S-SC except for model designation. Models NPort IA M-SC-T, MGate MB3170-M-SC and MGate MB3170-M-SC-T are identical to Model NPort IA M-SC except for model designation. Models NPort IA -5150I-S-SC-T, MGate MB3170I-S-SC and MGate MB3170I-S-SC-T are identical to Model NPort IA-5150I-S-SC except for model designation. Models NPort IA -5150I-M-SC-T, MGate MB3170I-M-SC and MGate MB3170I-M-SC-T are identical to Model IA -5150I-M-SC except for model designation. CD1.0 Additional Information CD1.1 Amendment 1: - Alternate new PWB added. - Added new models MGate MB3170, MGate MB3170-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, MGate MB3170I, MGate MB3170I-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M- SC-T, MGate MB3270, MGate MB3270-T, NPort IA -5250I, NPort IA-5250I-T, MGate MB3270I,

6 Issue Date: Page 4 of 8 Report Reference # E A19-UL-1 Amendment MGate MB3270I-T, see model differences for details. - Added alternate input rating. - Corrected typographical errors. - Updated National Differences (US/Canada/Annex NAF clauses) according to requirements in UL for document (paper) shredders used in home/home office (Standard UL , 1st Edition containing revisions through and including July 7, 2006). All for this product. Amendment 2: Add Models MGate EIP3170, MGate EIP3170I, MGate EIP3270, MGate EIP3270I, MGate EIP3170-T, MGate EIP3170I-T, MGate EIP3270-T and MGate EIP3270I-T. CE1.0 CE1.2 Technical Considerations The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 55 C, CE1.14 The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual

7 Issue Date: Page 5 of 8 Report Reference # E A19-UL-1 Amendment Clause Requirement + Test Result - Remark Verdict TABLE: list of critical components Pass Object/part No. Manufacturer/ trademark type/model technical data Product Category CCN(s) 01 Enclosure Various Various V-2 min., 120 degree C, 1.5 mm thick min. Two pieces construction, secured together by screws. Overall 120 by 90 mm. Required Marks of Conformity QMFZ2 UL Printed Wiring Board Various Various Min V-1, 105 degree C ZPMV2 UL RTC Battery (BT1) BR1225 BBCV2 UL (for all models) Panasonic Corporation, Panasonic Corporation Of North America Maximum reverse charging current 3 ma. Mounted on PWB, referred to Enclosure Ids 3-02, 3-04, 3-06, 3-08, 3-10, 3-12 and Label Various Various Min. 40 degree C, if max. surface temperature not specified 05 Terminal Block Dinkle Enterprise Co., Ltd. 06A Power Adapter (optional) 06B DC Power Supplyalternate (optional) 5EHD*d (*d:followed by R or V,may be follow by C and/or M, followed by 2-7 alphanumeric digits) 300 V, 15 A, 105 degree C, AWG 12 to 28 Solid, stranded, FW2, screw torque 4.5 lb. In. must be shown near screw Various Various Provided with a connector for field wiring terminal. O/P: Vdc, 510 ma min. mark with "LPS" or "Limited Power Source" or "Class 2" on unit Various Various Provided with a connector for field wiring terminal. O/P: Vdc, 510 ma min., meet the PGDQ2/PDJI2 UL XCFR2 UL 3-02 QQGQ/ EPBU QQGQ/QQGQ2 UL UL Supplement ID

8 Issue Date: Page 6 of 8 Report Reference # E A19-UL-1 Amendment Clause Requirement + Test Result - Remark Verdict 07. Fiber Optical Transceiver Output connector for models: NPort IA- 5150, NPort IA-5150-T, MGate MB3170, MGate MB3170-T, NPort IA- 5150I, NPort IA T, MGate MB3170I, MGate MB3170I-T Output connector for models: NPort IA- 5250, NPort IA-5250-T, MGate MB3270, MGate MB 3270-T, NPort IA- 5250I, NPort IA-5250I-T, MGate MB3270I, MGate MB 3270I-T Output connector for models: NPort IA S-SC, NPort IA S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T Output connector for models: NPort IA M-SC, NPort IA- SANway Optoelectronics technology Corporation SX1X2X3X4X5- X6X7X8X9X10 "LPS" requirements. Two provided, for optical fiber transceiver Single mode. Laser Class V, 90mA One series (SR-232) port, one SR-422/485 port, two RJ45 ports Two series (RS-232) ports, two RJ45 ports One series (RS-232) port, one SR-422/485 port, one Fiber Optical Transceiver (single mode or multi mode) One series (RS-232) port, one SR-422/485 port, one Fiber Optical Transceiver (single

9 Issue Date: Page 7 of 8 Report Reference # E A19-UL-1 Amendment Clause Requirement + Test Result - Remark Verdict 5150-M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T 09 Connectors and Receptacles (secondary mode or multi mode) -- Metal/Plastic Copper alloy pins housed in bodies of plastic rated V-2 min. ELV/SELV circuits) 10 Interconnecting Cable Various Various Optional, rated minimum 30 V, 60 degree C, Max m long, jacketed, marked "VW-1" or "FT-1" Lithium battery (BT1) (for Models NPort IA-5150, NPort IA T, MGate MB3170,MGate MB3170-T, MGate EIP3170, MGate EIP3170-T, NPort IA S-SC, NPort IA S-SC-T,MGate MB3170-S-SC,MGate MB3170-S-SC-T, NPort IA-5150-M-SC, NPort IA M-SC-T,MGate MB3170-M-SC,MGate MB3170-M-SC-T) Lithium battery (BT1) (for Models NPort IA-5150I, NPort IA- 5150I-T,MGate Panasonic Corporation, Panasonic Corporation Of North America Panasonic Corporation, Panasonic Corporation Of North VL1220 VL1220 Maximum abnormal charging current of 300 ma. Reverse current protection by series circuit of diode D21 and resistor R142, rated 1.5 k ohm. Mounted on PWB, referred to Enclosure Ids 3-15 and Maximum abnormal Charging Current 300 ma. Reverse current protection by series circuit of diode D21 and resistor QMFZ2, ECBT2, RTRT2 AVLV2, DVPJ BBCV2 BBCV2 UL UL UL UL

10 Issue Date: Page 8 of 8 Report Reference # E A19-UL-1 Amendment Clause Requirement + Test Result - Remark Verdict MB3170I,MGate MB3170I-T, MGate EIP3170I, MGate EIP3170I-T NPort IA- 5150I-S-SC,NPort IA- 5150I-S-SC-T,MGate MB3170I-S-SC,MGate MB3170I-S-SC-T, NPort IA-5150I-M-SC,NPort IA- 5150I-M-SC-T,MGate MB3170I-M-SC,MGate MB3170I-M-SC-T) Lithium battery (BT1) (for Models NPort IA-5250, NPort IA T, MGate MB3270,MGate MB3270-T, MGate EIP3270 and MGate EIP3270-T, NPort IA- 5250I,NPort IA-5250I- T,MGate MB3270I,MGate MB3270I-T, MGate EIP3270I and MGate EIP3270I-T) America Panasonic Corporation, Panasonic Corporation Of North America VL1220 R143, rated 1.5 k ohm. Mounted on PWB, referred to Enclosure Ids 3-17, 3-18 and Maximum abnormal Charging Current 300 ma. Reverse current protection by series circuit of diode D6 and resistor R124, rated 1.5 k ohm. Mounted on PWB, referred to Enclosure Ids 3-20 and BBCV2 UL

11 Issue Date: Page 1 of 2 Report Reference # E A19-UL-1 Amendment Enclosure Test Record Description Test Record 1 Datasheet CRD Test Record 2 Data sheets CRD Test Record 3

12 Issue Date: Page 2 of 2 Report Reference # E A19-UL-1 Amendment Test Record No. 3 --No test was considered necessary based on adding Models NPort 5450IX, NPort 5450X and MGate MB348nX, employing the additional Models MGate EIP3170, MGate EIP3170I, MGate EIP3270, MGate EIP3270I, MGate EIP3170-T, MGate EIP3170I-T, MGate EIP3270-T and MGate EIP3270I-T, and there was no construction changed. --The results of this investigation, including construction review and testing, indicate that the products evaluated comply with the applicable requirements in the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment, Including Electrical Business Equipment, CAN/CSA-C22.2 No , First Edition, including revisions through revision date July 7, 2006, and UL , First Edition, including revisions through revision date October 31, Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL.

13 Issue Date: Page 1 of 2 Report Reference # E A19-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Information Technology Equipment Including Electrical Business Equipment NWGQ, NWGQ7 Listing NPort IA Series Device Service 1) NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate MB3270I-T. 2) NPort IA-5150-S-SC, NPort IA-5150-S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate MB3170I-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T. 3) NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGate MB3170-T, NPort IA-5250, NPort IA-5250-T, MGate MB3270, MGate MB3270-T. Rating(s): 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional) 3) Vdc, maximum 435 ma (Optional) Standards: UL , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) Applicant Name and Address: MOXA INC 4TH FL 135 LANE 235 PAO CHIAO RD SHING TIEN CITY TAIPEI 231 TAIWAN This Report includes the following parts, in addition to this cover page: 1. Specific Technical Criteria 2. Clause Verdicts 3. Critical Components 4. Test Results 5. National Differences 6. Enclosures Copyright 2008

14 Issue Date: Page 2 of 2 Report Reference # E A19-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. Any information and documentation involving UL Mark services are provided on behalf of (UL) or any authorized licensee of UL. Test Report By: Reviewed By: Timothy Geiger Staff Engineer Robert Hilbrecht Staff Engineer Copyright 2008

15 Issue Date: Page 1 of 41 Report Reference # E A19-UL-1 SPECIFIC TECHNICAL CRITERIA UL , First Edition Information technology equipment - Safety- Part 1: General Requirements Report Reference No...: E A19-UL-1 Compiled by...: Timothy Geiger Reviewed by...: Robert Hilbrecht Date of issue...: Standards...: UL , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No , 1st Edition, (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure...: Listing Non-standard test method...: Test item description...: NPort IA Series Device Service Trademark...: None Model and/or type reference...: 1) NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate MB3270I-T. 2) NPort IA-5150-S-SC, NPort IA-5150-S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate MB3170I-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T. 3) NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGate MB3170-T, NPort IA-5250, NPort IA-5250-T, MGate MB3270, MGate MB3270-T. Rating(s)...: 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional) 3) Vdc, maximum 435 ma (Optional)

16 Issue Date: Page 2 of 41 Report Reference # E A19-UL-1 Particulars: test item vs. test requirements Equipment mobility...: movable Operating condition...: continuous Mains supply tolerance (%)...: No direct connection Tested for IT power systems...: No IT testing, phase-phase voltage (V)...: Class of equipment...: Class III (supplied by SELV) Mass of equipment (kg)...: 0.16 Protection against ingress of water...: IP20 Possible test case verdicts: - test case does not apply to the test object...: N / A - test object does meet the requirement...: Pass - test object does not meet the requirement...: Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator

17 Issue Date: Page 3 of 41 Report Reference # E A19-UL-1 GENERAL PRODUCT INFORMATION: CA1.0 CA1.1 Report Summary CB1.0 CB1.1 Product Description The unit was configured as follows: Consists of electronic components mounted on PWB, Fiber connector, Series connector (SR-232), SR422/485 connector or Ethernet(RJ45) connector, and housed with plastic enclosure. CC1.0 CC1.1 Model Differences All models are similar to NPort IA-5150 except for output connector type and model designation detailed as blew. Model NPort IA-5150-T is identical to Model NPort IA-5150 except for model designation. Model NPort IA-5150I-T is identical to Model NPort IA-5150I except for model designation. Model NPort IA-5250-T is identical to Model NPort IA-5250 except for model designation. Model NPort IA-5150-S-SC-T is identical to Model NPort IA-5150-S-SC except for model designation. Model NPort IA-5150-M-SC-T is identical to Model NPort IA-5150-M-SC except for model designation. Model NPort IA-5150I-S-SC-T is identical to Model NPort IA-5150I-S-SC except for model designation. Model NPort IA-5150I-M-SC-T is identical to Model IA-5150I-M-SC except for model designation. Models MGate MB3170 and MGate MB3170-T are identical to Models NPort IA-5150 and NPort IA-5150-T except for model designation. Models MGate MB3170-S-SC and MGate MB3170-S-SC-T are identical to Models NPort IA-5150-S-SC and NPort IA-5150-S-SC-T except for model designation. Models MGate MB3170-M-SC and MGate MB3170-M-SC-T are identical to Models NPort IA-5150-M-SC and NPort IA-5150-M-SC-T except for model designation. Models MGate MB3170I and MGate MB3170I-T are identical to Models NPort IA-5150I and NPort IA-5150I-T except for models designation. Models MGate MB3170I-S-SC and MGate MB3170I-S-SC-T are identical to Models NPort IA-5150I-S-SC and NPort IA-5150I-S-SC-T except for models designation. Models MGate MB3170I-M-SC and MGate MB3170I-M-SC-T are identical to Models NPort IA-5150I-M-SC and NPort IA-5150I-M-SC-T except for models designation. Models MGate MB3270 and MGate MB 3270-T are identical to Models NPort IA-5250 and NPort IA-5250-T except for model designation. Models NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I and MGate MB3270I-T are identical to Models NPort IA-5250 and NPort IA-5250-T except for model designation.

18 Issue Date: Page 4 of 41 Report Reference # E A19-UL-1 CD1.0 Additional Information CD1.1 Amendment 1: - Alternate new PWB added. - Added new models MGate MB3170, MGate MB3170-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, MGate MB3170I, MGate MB3170I-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T, MGate MB3270, MGate MB3270-T, NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate MB3270I-T, see model differences for details. - Added alternate input rating. - Corrected typographical errors. - Updated National Differences (US/Canada/Annex NAF clauses) according to requirements in UL for document (paper) shredders used in home/home office (Standard UL , 1st Edition containing revisions through and including July 7, 2006). All for this product. CE1.0 CE1.2 Technical Considerations The product was submitted and tested for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 55 C,

19 Issue Date: Page 5 of 41 Report Reference # E A19-UL-1 SPECIFIC INSPECTION CRITERIA BA1.0 BA1.1 Special Instructions to UL Representative BB1.0 BB1.1 Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions - i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. BC1.0 BC1.1 BC1.2 Markings and instructions The following markings and instructions are provided as indicated. All clause references are from UL :2003, First Edition. Standard Clause Clause Title Power rating - Company identification Power rating - Model Replaceable batteries Other Operating/Instruc tion/safety Manual Marking or Instruction Details Listee's or Recognized company's name, Trade Name, Trademark or File Number Model Number "CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used Batteries According to the Instructions." Provided with each unit. "This product is intended to be supplied by a Listed Power Unit and output marked with "LPS" and rated Vdc, 510 ma max. requirements" equivalent statement provided in operating manual.

20 Issue Date: Page 6 of 41 Report Reference # E A19-UL-1 BD1.0 BD1.1 BD1.2 BD1.3 BD1.4 Production-Line Testing Requirements Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for further information. Test Potential Model Component Removable Parts Test probe location Earthing Continuity Test Exemptions - This test is not required for the following models: Electric Strength Test Exemptions - This test is not required for the following models: Electric Strength Test Component Exemptions - The following solid-state components may disconnected from the remainder of the circuitry during the performance of this test: V rms V dc Test Time, s BE1.0 BE1.1 Sample and Test Specifics for Follow-Up Tests at UL Model Component Material Test Sample(s) Test Specifics

21 Issue Date: Page 7 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict 1 GENERAL Pass 1.5 Components Pass General Pass Comply with IEC or relevant component standard (See appended table 1.5.1) Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard. Components not certified are used in accordance with their ratings and they comply with IEC60950 and the relevant component Standard. Components, for which no relevant IEC Standard exist, have been tested under the condition occurring in the equipment, using applicable parts of IEC Thermal controls Transformers Interconnecting cables Interconnecting cables comply with the relevant requirements of this standard Capacitors in primary circuits... : Double insulation or reinforced insulation bridged by components General Bridging capacitors Bridging resistors Accessible parts Components in equipment for IT power systems Unit not provided with means for connection to mains. Pass Pass Pass 1.6 Power interface Pass AC power distribution systems Supplied by SELV.

22 Issue Date: Page 8 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Input current The steady state input current of the equipment did not exceed the RATED CURRENT by more than 10% under NORMAL LOAD. (See appended table 1.6.2) Voltage limit of hand-held equipment Not hand-held equipment Neutral conductor -- Pass 1.7 Marking and instructions Pass Power rating Rated voltage(s) or voltage range(s) (V)... : Optional, Vdc Symbol for nature of supply, for d.c. only... : Optionally marked with dc symbol. Rated frequency or rated frequency range (Hz)... : Rated current (ma or A)... : 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional) 3) Vdc, maximum 435 ma (Optional) Manufacturer's name or trademark or identification mark... : Moxa Inc. or E Type/model or type reference... : See cover page for details. Symbol for Class II equipment only... : Class III equipment. Other symbols... : Additional symbols may be provided when submitted for National Approval. Certification marks... : Safety instructions Safety instructions in English. Other languages will be provided when submitted for national approval Short duty cycles The equipment is intended for continuous operation Supply voltage adjustment... : Power outlets on the equipment... : No standard power outlets are provided. Pass Pass Pass Pass Pass Pass Pass

23 Issue Date: Page 9 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Fuse identification... : Wiring terminals Protective earthing and bonding terminals... : Terminal for a.c. mains supply conductors Terminals for d.c. mains supply conductors Controls and indicators Identification, location and marking... : Colours... : Symbols according to IEC : There are no switches in the equipment Markings using figures... : Isolation of multiple power sources... : IT power distribution systems Unit not provided with means for connection to mains Thermostats and other regulating devices No adjustable thermostats Language... : Reviewed only English. Other languages will be provided when submitted for national approval Durability The marking(s) withstood the required test. Pass Removable parts Marking is not placed on removable parts Replaceable batteries Following statement provided on outer surface of battery pack or in user and service manual, or as described in individual descriptive sections: "Caution. Danger Of Explosion If Battery Is Incorrectly Replaced. Replace Only With The Same Or Equivalent Type Recommended By The Manufacturer. Dispose Of Used Batteries According To The Manufacturer's Instructions." Language... : English - Pass Pass

24 Issue Date: Page 10 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Operator access with a tool... : There is no hazard parts can be touched for operator access with a tool Equipment for restricted access locations... : Equipment not intended for installation in a RESTRICTED ACCESS LOCATION. Pass 2 PROTECTION FROM HAZARDS Pass 2.1 Protection from electric shock and energy hazards Protection in operator access areas Access to energized parts Test by inspection... : Supply by SELV. Test with test finger... : Supply by SELV. Test with test pin... : Supply by SELV. Test with test probe... : Battery compartments... : No battery compartments Access to ELV wiring Internal wiring in an ELV circuit is not user accessible. Working voltage (V); minimum distance (mm) through insulation... : Access to hazardous voltage circuit wiring No internal wiring accessible to user Energy hazards... : Manual controls The equipment does not contain any knobs, handles, levers, or the like Discharge of capacitors in equipment -- Time-constant (s); measured voltage (V)... : Protection in service access areas Protection in restricted access locations The unit is not intended to be used in restricted locations. 2.2 SELV circuits Pass General requirements Supplied by SELV. Pass Voltages under normal conditions (V)... : All accessible voltages are Pass

25 Issue Date: Page 11 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict less than 42.4 Vpk or 60 V dc and are classified as SELV Voltages under fault conditions (V)... : Separation by double insulation or reinforced insulation (method 1) Class III equipment Separation by earthed screen (method 2) Protection by earthing of the SELV circuit (method 3) Connection of SELV circuits to other circuits... : See 2.2.2, The SELV has not connect to Primary circuit directly. Pass 2.3 TNV circuits Limits -- Type of TNV circuits... : No TNV CIRCUITS Separation from other circuits and from accessible parts Insulation employed... : Separation from hazardous voltages Insulation employed... : Connection of TNV circuits to other circuits Insulation employed... : Test for operating voltages generated externally 2.4 Limited current circuits General requirements Limit values Frequency (Hz)... : - Measured current (ma)... : - Measured voltage (V)... : - Measured capacitance (mf)... : Connection of limited current circuits to other circuits

26 Issue Date: Page 12 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict 2.5 Limited power sources Inherently limited output Impedance limited output Overcurrent protective device limited output Regulating network limited output under normal operating and single fault condition Regulating network limited output under normal operating conditions and overcurrent protective device limited output under single fault condition Output voltage (V), output current (A), apparent - power (VA):... : Current rating of overcurrent protective device (A) : Provisions for earthing and bonding Protective earthing Functional earthing Protective earthing and protective bonding conductors General Size of protective earthing conductors Rated current (A), cross-sectional area (mm2), - AWG... : Size of protective bonding conductors Rated current (A), cross-sectional area (mm2), - AWG... : Resistance (Ohm) of earthing conductors and their terminations, test current (A)... : Colour of insulation... : Terminals General Protective earthing and bonding terminals Rated current (A), type and nominal thread diameter (mm)... : -

27 Issue Date: Page 13 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Separation of the protective earthing conductor from protective bonding conductors Integrity of protective earthing Interconnection of equipment Components in protective earthing conductors and protective bonding conductors Disconnection of protective earth Parts that can be removed by an operator Parts removed during servicing Corrosion resistance Screws for protective bonding Reliance on telecommunication network or cable distribution system 2.7 Overcurrent and earth fault protection in primary circuits Basic requirements Instructions when protection relies on building installation Faults not covered in Short-circuit backup protection Number and location of protective devices... : Protection by several devices Warning to service personnel... : 2.8 Safety interlocks General principles No Safety Interlock Protection requirements Inadvertent reactivation Fail-safe operation Moving parts Overriding

28 Issue Date: Page 14 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Switches and relays Contact gaps (mm)... : Overload test Endurance test Electric strength test Mechanical actuators 2.9 Electrical insulation Pass Properties of insulating materials Natural rubber, materials containing asbestos and hygroscopic materials are not used as insulation Humidity conditioning Humidity (%)... : - Temperature ( C)... : Grade of insulation FUNCTIONAL INSULATION. Pass Pass 2.10 Clearances, creepage distances and distances through insulation Pass General See below. Pass Determination of working voltage Clearances (See appended table and ) General Class III product - Secondary circuits complied with Subclause Clearances in primary circuit Clearances in secondary circuits (See appended table and ) Measurement of transient voltage levels Creepage distances (See appended table and ) CTI tests... : Material group IIIb; 100 <= - CTI < Solid insulation Pass Pass Pass Pass

29 Issue Date: Page 15 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Minimum distance through insulation Thin sheet material Number of layers (pcs)... : - Electric strength test... : Printed boards PWB is not used as reinforced or supplementary insulation. Distance through insulation Electric strength test for thin sheet insulating material... : Number of layers (pcs)... : Wound components Number of layers (pcs)... : Two wires in contact inside wound component; angle between 45 and : Coated printed boards No coated printed wiring boards General Sample preparation and preliminary inspection Thermal cycling Thermal ageing ( C)... : Electric strength test... : Abrasion resistance test Electric strength test... : Enclosed and sealed parts... : No hermetically sealed or enclosed components used. Temperature T1=T2 = Tma - Tamb +10K ( C)... : Spacings filled by insulating compound... : Electric strength test... : Component external terminations Insulation with varying dimensions - 3 WIRING, CONNECTIONS AND SUPPLY Pass

30 Issue Date: Page 16 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict 3.1 General Pass Current rating and overcurrent protection No internal wiring/interconnection cables Protection against mechanical damage Securing of internal wiring No internal wiring/interconnection cables Insulation of conductors The insulation of the individual conductors are suitable for the application and the working voltage Beads and ceramic insulators The equipment does not have any beads or similar insulators Screws for electrical contact pressure Electrical screw connection is not used Insulating materials in electrical connections No contact pressure through insulating material Self-tapping and spaced thread screws Thread-cutting or space thread screws are not used for electrical connections Termination of conductors 10 N pull test Sleeving on wiring Sleeving is not used as supplementary insulation. Pass 3.2 Connection to an a.c. mains supply or a d.c. mains supply Means of connection Connection to an a.c. mains supply Connection to a d.c. mains supply Multiple supply connections Permanently connected equipment Number of conductors, diameter (mm) of cable and - conduits... : Appliance inlets Power supply cords AC power supply cords

31 Issue Date: Page 17 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Type... : - Rated current (A), cross-sectional area (mm²), - AWG... : DC power supply cords Cord anchorages and strain relief Mass of equipment (kg), pull (N)... : - Longitudinal displacement (mm)... : Protection against mechanical damage Cord guards D (mm); test mass (g)... : - Radius of curvature of cord (mm)... : Supply wiring space 3.3 Wiring terminals for connection of external conductors Wiring terminals Connection of non-detachable power supply cords Screw terminals Conductor sizes to be connected Rated current (A), cord/cable type, cross-sectional - area (mm²)... : Wiring terminal sizes Rated current (A), type and nominal thread - diameter (mm)... : Wiring terminals design Grouping of wiring terminals Stranded wire 3.4 Disconnection from the mains supply General requirement Disconnect devices Permanently connected equipment Not permanently connected

32 Issue Date: Page 18 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict equipment Parts which remain energized Switches in flexible cords Single-phase equipment and d.c. equipment Three-phase equipment Switches as disconnect devices Plugs as disconnect devices Interconnected equipment Multiple power sources 3.5 Interconnection of equipment Pass General requirements This equipment is not considered for connection to TNV Types of interconnection circuits... : Interconnection circuits are SELV CIRCUITS ELV circuits as interconnection circuits No ELV interconnection Pass Pass 4 PHYSICAL REQUIREMENTS Pass 4.1 Stability Pass Angle of 10 Test: force (N)... : Based on construction, the test was deemed not necessary. Pass 4.2 Mechanical strength Pass General Steady force test, 10 N Steady force test, 30 N Steady force test, 250 N Impact test Fall test

33 Issue Date: Page 19 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Swing test Drop test Not hand-held equipment Stress relief test Cathode ray tubes No Cathode ray tubes Picture tube separately certified... : High pressure lamps No High pressure lamps Wall or ceiling mounted equipment; force (N)... : Mounting means withstands four times unit weight or 50N minimum. Pass 4.3 Design and construction Pass Edges and corners All edges and corners are judged to be sufficiently well rounded so as not to constitute a hazard Handles and manual controls; force (N)... : Adjustable controls No setting for power supply voltage Securing of parts Electrical and mechanical connections can be expected to withstand usual mechanical stress. For the protection, solder pins, cable ties and heat shrunk tubing are used Connection of plugs and sockets The equipment does not have any interchangeable plugs/sockets Direct plug-in equipment Not Direct plug-in equipment Dimensions (mm) of mains plug for direct plug-in. : The equipment is not plug-in type. Torque and pull test of mains plug for direct plug-in; torque (Nm); pull (N)... : The equipment is not plug-in type Heating elements in earthed equipment Batteries Battery is protected against charging current by components Diode and Resistor rated 1.5Kohm. See Table for specific component identification. Pass Pass

34 Issue Date: Page 20 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Abnormal reverse current = 0.1 ma < 3.0 ma Oil and grease The insulation of the internal wiring is not exposed to oil, grease, etc Dust, powders, liquids and gases The equipment does not produce or employ powders, liquids, or gases Containers for liquids or gases The equipment does not contain liquid Flammable liquids... : Flammable liquids has not used. Quantity of liquid (l)... : Flash point ( C)... : Radiation; type of radiation Ionizing radiation or laser or in which similar hazards are not presents General Ionizing radiation Measured radiation (pa/kg)... : - Measured high-voltage (kv)... : - Measured focus voltage (kv)... : - CRT markings... : Effect of ultraviolet (UV) radiation on materials Part, property, retention after test, flammability classification... : Human exposure to ultraviolet (UV) radiation... : Laser (including LEDs) Laser class... : Other types... : 4.4 Protection against hazardous moving parts General Equipment does not have any hazardous moving parts Protection in operator access areas

35 Issue Date: Page 21 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Protection in restricted access locations Protection in service access areas 4.5 Thermal requirements Pass Maximum temperatures (See appended table 4.5) Pass Normal load condition per Annex L... : Operated in the most unfavorable way of operation given in the operating instructions until steady conditions established Resistance to abnormal heat Pass 4.6 Openings in enclosures Pass Top and side openings Pass Dimensions (mm)... : No openings Bottoms of fire enclosures Pass Construction of the bottom... : No openings Doors or covers in fire enclosures Openings in transportable equipment Not transportable equipment Adhesives for constructional purposes No barrier or screen secured with adhesive. Conditioning temperature ( C)/time (weeks)... : Resistance to fire Pass Reducing the risk of ignition and spread of flame Method 1: Selection and application of components and materials which minimize the possibility of ignition and spread of flame. Method 1, selection and application of components wiring and materials Method 2, application of all of simulated fault condition tests Conditions for a fire enclosure With having the following components: Pass Pass Pass

36 Issue Date: Page 22 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict - Components in secondary circuits supplied by LPS (limited power source) and mounted on materials of flammability class V-1. No fire enclosure is required Parts requiring a fire enclosure See Parts not requiring a fire enclosure Pass Materials Pass General Materials for fire enclosures No fire enclosure is required Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures All internal materials are rated V-2 or better or are mounted on a PWB rated V-1 or better Materials for air filter assemblies No air filter assemblies Materials used in high-voltage components No high-voltage components Pass 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass 5.1 Touch current and protective conductor current General Secured by approved power supply unit Equipment under test (EUT) Test circuit Application of measuring instrument Test procedure Test measurements Test voltage (V)... : - Measured touch current (ma)... : - Max. allowed touch current (ma)... : - Measured protective conductor current (ma)... : - Max. allowed protective conductor current (ma)... : Equipment with touch current exceeding 3.5 ma.. :

37 Issue Date: Page 23 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Touch currents to and from telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network and a cable distribution system Test voltage (V)... : - Measured touch current (ma)... : - Max. allowed touch current (ma)... : Summation of touch currents from telecommunication networks... : 5.2 Electric strength General Test procedure 5.3 Abnormal operating and fault conditions Pass Protection against overload and abnormal operation Motors The equipment does not have any motors Transformers Functional insulation... : Complies with (a), (b) or (c). Pass Electromechanical components Simulation of faults Refer Table 5.3 Pass Unattended equipment The equipment does not have any thermostats, temperature limiters, or thermal cut-outs Compliance criteria for abnormal operating and fault conditions No fire, emission of molten metal or deformation was noted during the test. Pass 6 CONNECTION TO TELECOMMUNICATION NETWORKS 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment

38 Issue Date: Page 24 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Protection from hazardous voltages Separation of the telecommunication network from earth Requirements Test voltage (V)... : - Current in the test circuit (ma)... : Exclusions... : 6.2 Protection of equipment users from overvoltages on telecommunication networks Separation requirements Electric strength test procedure Impulse test Steady-state test Compliance criteria 6.3 Protection of the telecommunication wiring system from overheating Max. output current (A)... : - Current limiting method... : - 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS 7.1 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment 7.2 Protection of equipment users from overvoltages on the cable distribution system 7.3 Insulation between primary circuits and cable distribution systems General Voltage surge test Impulse test A Annex A, TESTS FOR RESISTANCE TO HEAT AND FIRE

39 Issue Date: Page 25 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see ) A.1.1 Samples... : - Wall thickness (mm)... : - A.1.2 Conditioning of samples; temperature ( C)... : A.1.3 Mounting of samples... : A.1.4 Test flame A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : - A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material... : - Wall thickness (mm)... : - A.2.2 Conditioning of samples A.2.3 Mounting of samples A.2.4 Test flame A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : - A.2.7 Alternative test acc. to IEC , cl. 4, 8 Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : -

40 Issue Date: Page 26 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion B Annex B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see and 5.3.2) B.1 General requirements Position... : - Manufacturer... : - Type... : - Rated values... : - B.2 Test conditions B.3 Maximum temperatures B.4 Running overload test B.5 Locked-rotor overload test Test duration (days)... : - Electric strength test: test voltage (V)... : - B.6 Running overload test for d.c. motors in secondary circuits B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 Test procedure B.7.2 Alternative test procedure; test time (h)... : B.7.3 Electric strength test B.8 Test for motors with capacitors B.9 Test for three-phase motors B.10 Test for series motors Operating voltage (V)... : - C Annex C, TRANSFORMERS (see and 5.3.3)

41 Issue Date: Page 27 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Position... : - Manufacturer... : - Type... : - Rated values... : - Method of protection... : - C.1 Overload test C.2 Insulation Protection from displacement of windings... : D Annex D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS D.1 Measuring instrument D.2 Alternative measuring instrument E Annex E, TEMPERATURE RISE OF A WINDING F Annex F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10) Pass G Annex G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES G.1 Summary of the procedure for determining minimum clearances G.2 Determination of mains transient voltage (V) G.2.1 AC mains supply G.2.2 DC mains supply G.3 Determination of telecommunication network transient voltage (V) :... : G.4 Determination of required withstand voltage (V)... : G.5 Measurement of transient levels (V)... : G.6 Determination of minimum clearances... :

42 Issue Date: Page 28 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict H ANNEX H, IONIZING RADIATION (see ) J Annex J, TABLE OF ELECTROCHEMICAL POTENTIALS (see ) Metal used... : - K ANNEX K, THERMAL CONTROLS (see and 5.3.7) K.1 Making and breaking capacity K.2 Thermostat reliability; operating voltage (V)... : K.3 Thermostat endurance test; operating voltage (V) : K.4 Temperature limiter endurance; operating voltage (V)... : K.5 Thermal cut-out reliability K.6 Stability of operation L Annex L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see and 4.5.1) L.1 Typewriters L.2 Adding machines and cash registers L.3 Erasers L.4 Pencil sharpeners L.5 Duplicators and copy machines L.6 Motor-operated files L.7 Other business equipment Pass Pass M Annex M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) M.1 Introduction M.2 Method A M.3 Method B M.3.1 Ringing signal M Frequency (Hz)... : -

43 Issue Date: Page 29 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict M Voltage (V)... : - M Cadence; time (s), voltage (V)... : - M Single fault current (ma)... : - M.3.2 Tripping device and monitoring voltage... : M Conditions for use of a tripping device or a monitoring voltage M Tripping device M Monitoring voltage (V)... : N Annex N, IMPULSE TEST GENERATORS (see , , and clause G.5) N.1 ITU-T impulse test generators N.2 IEC impulse test generator P Annex P, NORMATIVE REFERENCES Pass Q Annex Q, BIBLIOGRAPHY Pass R Annex R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S Annex S, PROCEDURE FOR IMPULSE TESTING (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing T Annex T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2)

44 Issue Date: Page 30 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict... : - U Annex U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see )... : -

45 Issue Date: Page 31 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict TABLE: electrical data (in normal conditions) Pass fuse # I rated (A) U (V) P (W) I (ma) I fuse (ma) condition/status Model: Nport IA Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150I Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150-S-SC Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150-M-SC Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150I-S-SC Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150I-M-SC

46 Issue Date: Page 32 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Test on Model MGate MB dc Maximum Normal Load dc Maximum Normal Load Test on Model MGate MB3170I dc Maximum Normal Load dc Maximum Normal Load Test on Model MGate MB dc Maximum Normal Load dc Maximum Normal Load Test on Model MGate MB3270I dc Maximum Normal Load dc Maximum Normal Load Test on Model NPort IA-5150-S- SC dc Maximum Normal Load dc Maximum Normal Load Test on Model NPort IA-5150I-S- SC dc Maximum Normal Load dc Maximum Normal Load Test on Model NPort IA-5150I-M- SC dc Maximum Normal Load dc Maximum Normal Load supplementary information: "Maximum normal load" was defined as follows: Connected with network and computer and operated continuously. Adapter rating 12Vdc for reference and TABLE: clearance and creepage distance measurements Pass clearance cl and creepage distance dcr at/of: Up (V) U r.m.s. (V) required cl (mm) cl (mm) required dcr (mm) supplementary information: dcr (mm) All circuits are SELV and only functional insulation required.

47 Issue Date: Page 33 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict TABLE: distance through insulation measurements distance through insulation di at/of: Up (V) test voltage (V) required di (mm) di (mm) supplementary information: 4.5 TABLE: temperature rise measurements Pass test voltage (V)... See below See below See below See below -- t1 ( C) t2 ( C) maximum temperature T of part/at: T ( C) allowed Tmax ( C) Test sample Model: Nport IA-5150I-M-SC Normal Condition Condi Conditio Conditio Conditio tion 1 (Origi nal) n 1 (Shift to 55) n 2 (Original ) n 2 (Shift to 55) Ambient D23 body C43 body L4 coil PWB near U PWB near U PWB near U C34 body RTC battery body U16 body Enclosure inside near U Enclosure outside near U Normal Condition Condi tion 3 (Origi nal) Conditio n 3 (Shift to 55) Conditio n 4 (Original ) Conditio n 4 (Shift to 55) Ambient D23 body C43 body L4 coil PWB near U PWB near U PWB near U

48 Issue Date: Page 34 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict C34 body RTC battery body U16 body Enclosure inside near U Enclosure outside near U temperature T of winding: R 1 (Ω) R 2 ( Ω) T ( C) allowed Tmax ( C) supplementary information: Conditions: Test Condition 1: 48Vdc (Horizontal), Duration 4hrs. 12mins. Test Condition 2: 48Vdc (Vertical), Duration 3hrs. 27mins. Test Condition 3: 12Vdc (Vertical), Duration 2hrs. 15mins. Test Condition 4: 12Vdc (Horizontal), Duration 4hrs. 25mins. insulation class Comments: The temperatures were measured by thermal couple method under worst case normal mode defined in and described in 1.6.2, at voltages described in With a specified max. ambient temperature of 55 degree C Allowed T max ( C) defined as below: Tmax (Enclosure inside near U4)=120 C Tmax (PWB)=105 C Tmax (RTC battery)=100 C Tmax (IC, Cap., Diode)=105 C Tmax (Wiring)=105 C External surfaces of equipment which may be touch Tmax(Plastic)=95 C TABLE: ball pressure test of thermoplastics allowed impression diameter (mm)... : part test temperature ( C) impression diameter (mm) supplementary information: 4.7 TABLE: resistance to fire Pass part manufacturer of material type of material thickness(mm) flammability class Printed Wiring Board Various Various -- V-1 min.

49 Issue Date: Page 35 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Internal Plastic Parts Plastic Enclosure supplementary information: -- Various Various -- V-2 min. Various Various 1.5 mm min. V-2 min. 5.2 TABLE: electric strength tests, impulse tests and voltage surge tests test voltage applied between: test voltage (V) a.c./d.c. breakdown Yes / No supplementary information: 5.3 TABLE: fault condition tests Pass component No. ambient temperature ( C)... : -- model/type of power supply... : -- manufacturer of power supply... : -- rated markings of power supply... : -- fault test voltage (V) test time fuse No. fuse current (A) Lithium Battery Reverse Current Measurement Test U15 (pins 4-8) result Short 48Vdc Measured abnormal reverse current = 0.1 ma. Maximum abnormal charging current = 3 ma Overload of Operator Accessible Connector Test Model: Nport IA-5150 RS232 connector pins 1~9 RS422/485 connector pins 1~5 Ethernet 1 (RJ-45) connector Overload 48Vdc C Overload 48Vdc C Overload 48Vdc C

50 Issue Date: Page 36 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict pins 1~8 Ethernet 2 Overload 48Vdc C (RJ-45) connector pins 1~ Model: Nport IA-5150I RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~5 Ethernet 1 Overload 48Vdc C (RJ-45) connector pins 1~8 Ethernet 2 Overload 48Vdc C (RJ-45) connector pins 1~ Model: Nport IA-5250 RS232 (P1) Overload 48Vdc C connector pins 1~9 RS232 (P2) Overload 48Vdc C connector pins 1~9 Ethernet 1 Overload 48Vdc C (RJ-45) connector pins 1~8 Ethernet 2 Overload 48Vdc C (RJ-45) connector pins 1~ Model: Nport IA-5150-S-SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~ Model: Nport IA-5150-M-SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 connector Overload 48Vdc C

51 Issue Date: Page 37 of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict pins 1~ Model: Nport IA-5150I-S-SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~ Model: Nport IA-5150I-M- SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~5 D5 Short circuit 48 Vdc 7 hrs Unit shut down, cell body = 38 degree C, enclosure = 27 degree C, ambient = 23 degree C, no hazards. D6 (2-3) Short circuit 48 Vdc 7 hrs Unit operation normally, cell body = 63 degree C, enclosure = 35 degree C, ambient = 23 degree C, no hazards. D20 (4-8) Short circuit 48 Vdc 7 hrs Unit operation normally, cell body = 66 degree C, enclosure = 37 degree C, ambient = 25 degree C, no hazards. supplementary information: Results Key: C - Circuit measures 0 Volts

52 Issue Date: Page 38of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict TABLE: list of critical components Pass Object/part No. Manufacturer/ trademark type/model technical data Product Category CCN(s) Required Marks of Conformity 01 Enclosure Various Various V-2 min., 120 degree C, 1.5 QMFZ2 UL 3-01 mm thick min. Two pieces construction, secured together by screws. Overall 120 by 90 mm. 02 Printed Wiring Board Various Various Min V-1, 105 degree C ZPMV2 UL Label Various Various Min. 40 degree C, if max. surface temperature not specified PGDQ2/PDJI2 UL 05 Terminal Block Dinkle Enterprise Co., Ltd. 06A Power Adapter (optional) 06B DC Power Supplyalternate (optional) 07. Fiber Optical Transceiver 5EHD*d (*d:followed by R or V,may be follow by C and/or M, followed by 2-7 alphanumeric digits) 300 V, 15 A, 105 degree C, AWG 12 to 28 Solid, stranded, FW2, screw torque 4.5 lb. In. must be shown near screw Various Various Provided with a connector for field wiring terminal. O/P: Vdc, 510 ma min. mark with "LPS" or "Limited Power Source" or "Class 2" on unit Various Various Provided with a connector for field wiring terminal. O/P: Vdc, 510 ma min., meet the "LPS" requirements. SANway Optoelectronics technology Corporation SX1X2X3X4X5- X6X7X8X9X10 Two provided, for optical fiber transceiver Single mode. Laser Class V, 90mA. XCFR2 UL 3-02 QQGQ/ EPBU UL QQGQ/QQGQ2 UL Supplement ID

53 Issue Date: Page 39of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict Output connector for models: NPort IA- 5150, NPort IA-5150-T, MGate MB3170, MGate MB3170-T, NPort IA- 5150I, NPort IA T, MGate MB3170I, MGate MB3170I-T Output connector for models: NPort IA- 5250, NPort IA-5250-T, MGate MB3270, MGate MB 3270-T, NPort IA- 5250I, NPort IA-5250I-T, MGate MB3270I, MGate MB 3270I-T Output connector for models: NPort IA S-SC, NPort IA S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T Output connector for models: NPort IA M-SC, NPort IA M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, One series (SR-232) port, one SR-422/485 port, two RJ45 ports Two series (RS-232) ports, two RJ45 ports One series (RS-232) port, one SR-422/485 port, one Fiber Optical Transceiver (single mode or multi mode) One series (RS-232) port, one SR-422/485 port, one Fiber Optical Transceiver (single mode or multi mode)

54 Issue Date: Page 40of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict MGate MB3170I-M-SC, MGate MB3170I-M-SC-T 09 Connectors and Receptacles (secondary ELV/SELV circuits) -- Metal/Plastic Copper alloy pins housed in bodies of plastic rated V-2 min. 10 Interconnecting Cable Various Various Optional, rated minimum 30 V, 60 degree C, Max m long, jacketed, marked "VW-1" or "FT-1" Lithium battery (BT1) (for Models NPort IA-5150, NPort IA T, MGate MB3170,MGate MB3170-T, NPort IA S-SC, NPort IA S-SC-T,MGate MB3170-S-SC,MGate MB3170-S-SC-T, NPort IA-5150-M-SC, NPort IA M-SC-T,MGate MB3170-M-SC,MGate MB3170-M-SC-T) Lithium battery (BT1) (for Models NPort IA-5150I, NPort IA- 5150I-T,MGate MB3170I,MGate MB3170I-T, NPort IA- 5150I-S-SC,NPort IA- 5150I-S-SC-T,MGate MB3170I-S-SC,MGate MB3170I-S-SC-T, NPort IA-5150I-M-SC,NPort IA- Matsushita Electric Co Ltd/ Panasonic Corporation or North America Matsushita Electric Industrial Co Ltd Panasonic Corp Of North America VL1220 VL1220 Maximum abnormal charging current of 300 ma. Reverse current protection by series circuit of diode D21 and resistor R142, rated 1.5 k ohm. Maximum abnormal Charging Current 300 ma. Reverse current protection by series circuit of diode D21 and resistor R143, rated 1.5 k ohm. QMFZ2, ECBT2, RTRT2 UL AVLV2, DVPJ UL BBCV2 UL BBCV2 UL

55 Issue Date: Page 41of 41 Report Reference # E A19-UL-1 Clause Requirement + Test Result - Remark Verdict 5150I-M-SC-T,MGate MB3170I-M-SC,MGate MB3170I-M-SC-T) Lithium battery (BT1) (for ModelsNPort IA-5250, NPort IA T, MGate MB3270,MGate MB3270-T, NPort IA- 5250I,NPort IA-5250I- T,MGate MB3270I,MGate MB3270I-T) Matsushita Electric Industrial Co Ltd Panasonic Corp Of North America VL1220 Maximum abnormal Charging Current 300 ma. Reverse current protection by series circuit of diode D6 and resistor R124, rated 1.5 k ohm. BBCV2 UL

56 Issue Date: Page 1 of 10 Report Reference # E A19-UL-1 Enclosure National Differences USA / Canada

57 Issue Date: Page 2 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict USA / Canada - Differences to :2001, First Edition 1.1 Equipment able to be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1, and when applicable, the National Electrical Safety Code, IEEE C Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded Special requirements apply to equipment intended for use outdoors For Pluggable Equipment Type A, the protection in the installation is assumed to be 20 A All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of CSA and UL component standards in Annex P All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like For other than limited power and TNV circuits, the type of output circuit identified for output connector External cable assemblies that exceed 3.05 m in length to be types specified in the NEC and CEC Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope Telephone line and extension cords and the like comply with UL 1863 and CSA C22.2 No Equipment intended for connection to a d.c. power (mains) distribution system is subject to special Pass Pass Pass Pass Pass Pass

58 Issue Date: Page 3 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict circuit classification requirements (e.g., TNV-2) Earthing of d.c. powered equipment provided. 1.7 Lamp replacement information indicated on lampholder in operator access area Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor Equipment voltage rating not higher than rating of the plug except under special conditions Special fuse replacement marking for operator accessible fuses Identification of terminal connection of the equipment earthing conductor Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used Marking located adjacent to terminals and visible during wiring Screw shell of Edison-base lampholder tied to the neutral conductor Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M b For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 ma peak or 30 ma d.c. under normal conditions b Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and routine testing.

59 Issue Date: Page 4 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict In the event of a single fault, the limits of apply to SELV circuits and accessible conductive parts. 2.5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with devices of higher ratings if operator replaceable. 2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth For Pluggable Equipment Type A, if neither a) or b) are applicable, the current rating of the circuit is taken as 20 A Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit Protective bonding conductors and their terminals of non-standard constructions (e.g. PWB traces) evaluated to limited short-circuit test of CSA C22.2 No Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US and Canada Data for selection of special external branch circuit overcurrent devices marked on the equipment Standard supply outlets protected by overcurrent device in accordance with the NEC, and CEC, Part Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring Additional requirements for overcurrent protection apply to equipment provided with panelboards Non-motor-operated equipment requiring special overcurrent protective device marked with device rating Multi-layer winding wire subject to UL component wire requirements in addition to and Annex U Permissible combinations of internal wiring/external cable sizes for overcurrent and short circuit

60 Issue Date: Page 5 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict protection All interconnecting cables protected against overcurrent and short circuit. 3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC and CEC, Part Permitted use for flexible cords and plugs Flexible cords provided with attachment plug rated 125% of equipment current rating Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord) Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC, Part Permanently connected equipment may have

61 Issue Date: Page 6 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict terminals or leads not smaller than No. 18 AWG (0.82 mm²) and not less than 152 mm in length for connection of field installed wiring If supply wires exceed 60 C, marking indicates use of 75 C or 90 C wiring for supply connection as appropriate Equipment compatible with suitable trade sizes of conduits and cables Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation Conductors in power supply cords sized according to NEC and CEC, Part I Power supply cords and cord sets incorporate flexible cords suitable for the particular application Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source Adequate wire bending space and volume of field wiring compartment required to properly make the field connections Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse. 3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm²) or smaller conductor if provided with upturned lugs, cupped washer or equivalent retention Terminals accept wire sizes (gauge) used in the

62 Issue Date: Page 7 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict U.S. and Canada Terminals accept current-carrying conductors rated 125% of the equipment current rating Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads Separate motor control device(s) required for cord-connected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V Vertically mounted disconnect devices oriented so up position of handle is "on" For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more Compartment housing high-pressure lamp marked to indicate risk of explosion Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit In addition to the IEC requirements, Direct Plug-in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30(Table NAE.6) Equipment using replenishable liquids marked to indicate type of liquid to be used Equipment that produces x-radiation and does not comply with under all conditions of servicing marked to indicate the presence of radiation where readily visible Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040

63 Issue Date: Page 8 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict and REDR C1370). 4.7 Automated information storage equipment intended to contain more than 0.76 m³ of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system Equipment for use in environmental air space other than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL Equipment for installation in space used for environmental air as described in Sec (c) of the NEC provided with instructions indicating suitability for installation in such locations Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m² or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications Wire marked "VW-1" or "FT-1" considered equivalent Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections Touch current due to ringing voltage for equipment containing telecommunication network leads Overloading of SELV connectors and printed wiring board receptacles accessible to the operator Tests interrupted by opening of a component repeated two additional times Test interrupted by opening of wire or trace subject to certain conditions. 6 Specialized instructions provided for telephones that may be connected to a telecommunications network. 6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network Special requirements for enameled wiring used as electrical separation provided between parts connected to telecommunication network and telecommunication circuitry intentionally isolated Markings/instructions provided per standard.

64 Issue Date: Page 9 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict from network Digital line termination equipment (e.g., NCTE) subject to separation requirements. 6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection. 6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable. 6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C). 6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions. 6.5 Acoustic pressure from an ear piece less than 136 dba for short duration disturbances, and less than 125 dba for handsets, 118 dba for headsets, and 121 dba for insert earphones, for long duration disturbances. 7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC. H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act, REDR C1370. M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations. M.4 Special requirements for message waiting and similar telecommunications signals. NAC Equipment intended for use with a generic secondary protector marked with suitable instructions. NAC Equipment intended for use with a specific primary or secondary protector marked with suitable instructions. NAF Household/Home Office Document Shredders NAF.1.7 Markings and instructions alert the user to key

65 Issue Date: Page 10 of 10 Report Reference # E A19-UL-1 SubClause Difference + Test Result - Remark Verdict safety considerations related to use of shredders, including not intended to be used by children, avoid touching document feed opening, avoid clothes and hair entanglement, and avoid aerosol products. NAF Safety interlock cannot be inadvertently activated by the articulated accessibility probe (figure NAF.1). NAF.3.4 Provided with an isolating switch complying with 3.4.2, including 3 mm contact gap, with appropriate markings associated with the switch. NAF.4.4 Hazardous moving parts are not accessible to the user, as determined using the articulated accessibility probe (figure NAF.1) and the accessibility probe/wedge (figures NAF.2/NAF.3).

66 Issue Date: Page 1 of 22 Report Reference # E A19-UL-1 Enclosure Photographs Supplement Id Description 3-01 Models NPort IA-5150(-T) overall view 3-02 Models NPort IA-5150(-T) internal view 3-03 Models NPort IA-5150I(-T) overall view 3-04 Models NPort IA-5150I(-T) internal view 3-05 Models NPort IA-5150I-M-SC(-T) overall view 3-06 Models NPort IA-5150I-M-SC(-T) internal view 3-07 Models NPort IA-5150I-S-SC(-T) overall view 3-08 Models NPort IA-5150I-S-SC(-T) internal view 3-09 Models NPort IA-5150-M-SC(-T) overall view 3-10 Models NPort IA-5150-M-SC(-T) internal view 3-11 Models NPort IA-5150-S-SC(-T) overall view 3-12 Models NPort IA-5150-S-SC(-T) internal view 3-13 Models NPort IA-5250(-T) overall view 3-14 Models NPort IA-5250(-T) internal view 3-15 Amendment 1 - Models NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGATE MB3170-T, internal view 3-16 Amendment 1 - Models NPort IA-5150-S-SC, NPort IA-5150-S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, internal view 3-17 Amendment 1 - Models NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate MB3170I-T, internal view 3-18 Amendment 1 - Models NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T,MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, internal view 3-19 Amendment 1 - Models NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T, internal view 3-20 Amendment 1 - Models NPort IA-5250, NPort IA-5250-T, MGate MB3270,MGate MB3270-T internal view 3-21 Amendment 1 - NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate MB3270I-T internal view

67 Issue Date: Page 2 of 22 Report Reference # E A19-UL-1 Photographs ID 3-01

68 Issue Date: Page 3 of 22 Report Reference # E A19-UL-1 Photographs ID 3-02

69 Issue Date: Page 4 of 22 Report Reference # E A19-UL-1 Photographs ID 3-03

70 Issue Date: Page 5 of 22 Report Reference # E A19-UL-1 Photographs ID 3-04

71 Issue Date: Page 6 of 22 Report Reference # E A19-UL-1 Photographs ID 3-05

72 Issue Date: Page 7 of 22 Report Reference # E A19-UL-1 Photographs ID 3-06

73 Issue Date: Page 8 of 22 Report Reference # E A19-UL-1 Photographs ID 3-07

74 Issue Date: Page 9 of 22 Report Reference # E A19-UL-1 Photographs ID 3-08

75 Issue Date: Page 10 of 22 Report Reference # E A19-UL-1 Photographs ID 3-09

76 Issue Date: Page 11 of 22 Report Reference # E A19-UL-1 Photographs ID 3-10

77 Issue Date: Page 12 of 22 Report Reference # E A19-UL-1 Photographs ID 3-11

78 Issue Date: Page 13 of 22 Report Reference # E A19-UL-1 Photographs ID 3-12

79 Issue Date: Page 14 of 22 Report Reference # E A19-UL-1 Photographs ID 3-13

80 Issue Date: Page 15 of 22 Report Reference # E A19-UL-1 Photographs ID 3-14

81 Issue Date: Page 16 of 22 Report Reference # E A19-UL-1 Photographs ID 3-15

82 Issue Date: Page 17 of 22 Report Reference # E A19-UL-1 Photographs ID 3-16

83 Issue Date: Page 18 of 22 Report Reference # E A19-UL-1 Photographs ID 3-17

84 Issue Date: Page 19 of 22 Report Reference # E A19-UL-1 Photographs ID 3-18

85 Issue Date: Page 20 of 22 Report Reference # E A19-UL-1 Photographs ID 3-19

86 Issue Date: Page 21 of 22 Report Reference # E A19-UL-1 Photographs ID 3-20

87 Issue Date: Page 22 of 22 Report Reference # E A19-UL-1 Photographs ID 3-21

88 Issue Date: Page 1 of 2 Report Reference # E A19-UL-1 Enclosure Manuals Supplement Id Description 6-01 Fiber DOC

89 Issue Date: Page 2 of 2 Report Reference # E A19-UL-1

90 Issue Date: Page 1 of 2 Report Reference # E A19-UL-1 Enclosure Miscellaneous Supplement Id Description 7-01 Mounting means

91 Issue Date: Page 2 of 2 Report Reference # E A19-UL-1

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2008-11-11 Page 1 of 2 Report Reference # E186249-A82-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): COVER PAGE FOR TEST REPORT Power Supplies for Information Technology Equipment Including Electrical Business

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-07-30 Page 1 of 6 Report Reference # E313912-A35-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-03-18 Page 1 of 11 Report Reference # E300305-A58-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 55 Report No.:L611332L009 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-05-26 Page 1 of 2 Report Reference # E310405-A9-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Power Supplies for

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF

More information

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009.

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009. ELECTRICAL TESTING 839.01 Hermon Laboratories Ltd. Tel.+972 4 628 8001 Fax.+972 4 628 8277 SAFETY TEST REPORT ACCORDING TO: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, IEC 60950-1:2005 (Second Edition)

More information

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ File E132594 Project 02ME17432 2003-02-09 REPORT on CORD CONNECTED CLASS 2 POWER UNITS Globtek Inc. Northvale, NJ Copyright 2003 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

A Test Lab Techno Corp.

A Test Lab Techno Corp. Report No. 1607CF12 age 1 of 52 TEST REORT AS/NZS60950.1:2011+A1:2013 Safety of Information Technology Equipment including Electrical business equipment Report Number.... : 1607CF12 Date of issue... :

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2011-01-12 Page 1 of 1 Report Reference # ASL10120310 COVER PAGE FOR TEST REPORT Test Item Description: Notebook PC Model/Type Reference: MS-16Y1 Rating(s): 19Vdc, 3.42A or 19Vdc, 4.74A Standards:

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 46 TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 160414015SZN-002 Date of issue... : May 09, 2016 Total number of pages... : 77 pages Applicant

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Issued to: Rotork Controls Inc. 675 Mile Crossing Blvd Rochester, NY 14624 USA Attention: Matt Cogill The products listed below are eligible to bear the CSA Mark shown

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

SPECIFIC TECHNICAL CRITERIA

SPECIFIC TECHNICAL CRITERIA Issue Date: 2007-01-23 Page 4 of 57 Report Reference # E116994-A34-UL-1 SPECIFIC TECHNICAL CRITERIA TEST REPORT UL 60601-1 Medical Electrical Equipment Part 1: General requirements for safety Report Reference

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 248792 Date of issue... : 2013-11-25

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1712057S.50A Date of issue... : 2017-04-13 Total number

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements Page 1 of 49 Report Reference No....: 81790 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2009 TEST REPORT :2006 Information technology equipment Safety Part 1: General

More information

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT File E170507 Project 01ME11924 June 15, 2001 REPORT ON POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Globtek Inc. Northvale, NJ Copyright 2001 Underwriters Laboratories

More information

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences:

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences: age 3 of 106 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. re-production samples without serial

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: GLOBAL ADVANTAGE INTERNATIONAL TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of GUAGDOG EAST OWER CO., LTD. Uninterruptible ower Supply Model(s): EA99300,EA99250,EA99200 repared For : GUAGDOG EAST OWER CO., LTD. o.6 orthern Industry

More information

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7 TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

National Standard. of the People s Republic of China

National Standard. of the People s Republic of China Translated English of Chinese Standard: GB4793.1-2007 www.chinesestandard.net Sales@ChineseStandard.net ICS 19.080; 71.040.10 L 09 National Standard GB of the People s Republic of China GB 4793.1-2007

More information

BATTERY CHARGERS NO. 3

BATTERY CHARGERS NO. 3 Date: January 10, 1992 BATTERY CHARGERS NO. 3 To: Subject: Manufacturers of Commercial/Industrial Battery Chargers Expansion of CSA Certification Service for Power Supplies to Include Low Voltage, Outdoor

More information

Line Gard. Underwriters Laboratories (UL) Applicable Code Notation

Line Gard. Underwriters Laboratories (UL) Applicable Code Notation Underwriters Laboratories (UL) UL 50E Enclosures for Electrical Equipment, Environmental Considerations 1.1 This standard applies to enclosures for electrical equipment intended to be installed and used

More information

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77 TECHNICAL REORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION SYSTEM NERA F77 ACCORDING TO EN 60950 (2000) REORT NO. 2002-3032 REVISION NO. 01 DET NORSKE VERITAS DET NORSKE VERITAS TECHNICAL

More information

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard Doc: ET 31(6126) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard UNINTERRUPTIBLE POWER SYSTEMS (UPS)

More information

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2003-09-25 Page 1 of 1 Report Reference # E203413-A17-CB-1 Test Item Description: Model/Type Reference: COVER PAGE FOR TEST REPORT Home Plug Device MS-6821 Rating(s): 100-240 Vac, 47-63 Hz,

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS

More information

Copy of marking plate. Page 2 of 50 Report No. TRS

Copy of marking plate. Page 2 of 50 Report No. TRS Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

File E Project 00SC October 9, 2000 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 00SC October 9, 2000 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT File E183744 Project 00SC10745 October 9, 2000 REPORT ON POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Sinpro Electronics Co., Ltd. Ping Tong Hsien, Taiwan Copyright

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-03-29 Page 1 of 10 Report Reference # E317867-A45- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: 60950-1, 2nd Edition, 2011-12-19 (Information Technology Equipment - Safety

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

Investigation into UK socket-outlets incorporating USB charging points

Investigation into UK socket-outlets incorporating USB charging points Investigation into UK socket-outlets incorporating USB charging points Electrical Safety First investigated a number of commercially available UK socket-outlets incorporating USB ports, as a repeat of

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical

ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements. Guideline Number 3 Electrical ICOMIA Global Conformity Guideline for ISO/ABYC Standards and Canadian TP 1332 requirements 1. PURPOSE sponsored by ABYC, BMF, ICOMIA, IMCI, and NMMA Author: Wieger de Wit Guideline Number 3 Electrical

More information

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information

LOW VOLTAGE DIRECTIVE TEST REPORT IEC / EN , First Edition Information technology equipment Safety Part 1: General requirements

LOW VOLTAGE DIRECTIVE TEST REPORT IEC / EN , First Edition Information technology equipment Safety Part 1: General requirements page 1 of 39 Report No.: L7D1808L658 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1 / EN 60950-1, First Edition Information technology equipment Safety Part 1: General requirements Report Reference No....

More information

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines. 1 PAPER 4 Sample Questions - C&G 2382 17th Edition full paper D 1 o/c 1 - A recommendation for the interval to the first periodic inspection shall be made by: a the installation electrician. b the main

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1271882 Master Contract: 165071 Project: 2429855 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention: Mr. Michael

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number.... : TEST REORT Information technology equipment Safety art 1: General requirements Date of issue... : 7 March, 2017 Total number of pages...

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT. IEC 62133: 2012 (Second Edition) Test Report issued under the responsibility of: TEST REORT, Second Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary

More information

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid coil for control in potentially explosive areas Type BZ Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used

More information

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied

More information