Technical Data. Dimensions

Size: px
Start display at page:

Download "Technical Data. Dimensions"

Transcription

1 Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush Output polarity DC Assured operating distance s a mm Reduction factor r Al 0.25 Reduction factor r Cu 0.23 Reduction factor r Nominal ratings Operating voltage U B V DC Switching frequency f Hz Hysteresis H typ. 3 % Reverse polarity protection Voltage drop U d 3 V Operating current I L ma Off-state current I r ma No-load supply current I 0 20 ma Time delay before availability t v 300 ms reverse polarity protected Operating voltage indicator LED, green Switching state indicator LED, yellow Functional safety related parameters MTTF d 630 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Ambient conditions Ambient temperature C ( F) Mechanical specifications Connection type screw terminals Core cross-section up to 2.5 mm 2 Housing material Sensing face Housing base Degree of protection IP68 information Use in the hazardous area see instruction manuals Category 3G; 3D Compliance with standards and directives Standard conformity Standards EN :2007 IEC :2007 Approvals and certificates UL approval culus Listed, Purpose CSA approval ccsaus Listed, Purpose CCC approval Certified by China Compulsory Certification (CCC) Dimensions LEDs ø M20 x ø LEDs 1

2 Electrical Connection L+ L- Installation Hint These sensors are especially designed for embeddable mounting in conveyor floors. Due to its precise location in metal base plates the sensor is afforded a high degree of mechanical protection. No clearance is required between the sensor and the base plate, avoiding the need for protective guarding to prevent possible foot injury. The large sensing range ensures positive detection, and thus provides consistent control and monitoring of the conveyor. 2

3 ATEX 3G (na) Device category 3G (na) Certificate of Compliance for use in hazardous areas with gas, vapour and mist PF 15CERT3754 X II 3G Ex na IIC T6 Gc The Ex-related marking can also be printed on the enclosed label. Standards EN :2012+A11:2013, EN :2010 Ignition protection category "n" Use is restricted to the following stated conditions The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be observed! Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-related marking is printed only on the supplied label, then this must be attached in the immediate vicinity of the sensor. The sticking surface for the label must be clean and free from grease. The attached label must be legible and indelible, including in the event of possible chemical corrosion. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. Maximum operating voltage U Bmax The maximum permissible operating voltage UB max is restricted to the values in the following list. Tolerances are not permissible. Maximum permissible ambient temperature T Umax dependant of the load current I L and the max. operating voltage U Bmax. Information can be taken from the following list. 44 C (111.2 F) 45 C (113 F) 51 C (123.8 F) 55 C (131 F) 56 C (132.8 F) at U Bmax =30 V, I L =25 ma 57 C (134.6 F) Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Protection against transients Ensure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded. When used in group IIC non-permissible electrostatic charges should be avoided on the plastic housing parts. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS If cable glands are required for the installation then the following points must be observed: The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the application. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. Material selection accessories When selecting accessories, ensure that the material allows the temperature of the enclosure to rise to up to 70 C. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) 3

4 ATEX 3D Note Device category 3D This instruction is only valid for products according to EN , valid until 30-September-2008 Note the ex-marking on the sensor or on the enclosed adhesive label for use in hazardous areas with non-conducting combustible dust II 3D IP67 T 96 C (204.8 F) X Standards EN Protection via housing Use is restricted to the following stated conditions The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction! The special conditions must be adhered to! Laws and/or regulations and standards governing the use or intended usage goal must be observed. Repairs to these apparatus are not possible. The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum heating (Temperature rise) dependant of the load current I L and the max. operating voltage U Bmax. Information can be taken from the following list. The maximum surface temperature at maximum ambient temperature is given in the Ex identification of the apparatus. 26 K 25 K 22 K 22 K 19 K 15 K 13 K Protection from mechanical danger The sensor must not be mechanically damaged. Connections for external wire Sliding contact discharges must be avoided. s must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Terminal connection: Minimum conductor cross-section: 0.5 mm 2, maximum conductor cross-section: 2.5 mm 2. The ends of the conductor must be provided with cable sleeves. The cable entry must be such, that no tension load or twist is applied to the cable The protection category must be in accordance with EN and as stated in the data sheet. The cable entry must be designed so that there are no sharp edges to damage the cable and impair the level of protection of the sensor. The cable entry must be in accordance with the relevant European standard for industrial cable and lead entries.. In addition, in the case of flexible leads, the points of entry of the cable must be rounded off over an angle of at least 75, with a radius (R), which is at least one quarter of the maximum permissible cable diameter for the entry, but not greater than 3 mm. The plug connector must not be disconnected under voltage. The proximity switch is marked as follows: "DO NOT DISCON- NECT UNDER VOLTAGE!" When the plug connector is disconnected the ingress of dirt into the inner areas (i.e. the areas, which are not accessible in the plugged-in condition) must be prevented. 4

5 ATEX 3D (tc) Device category 3D Certificate of Compliance for use in hazardous areas with combustible dust PF 15CERT3774 X II 3D Ex tc IIIC T80 C Dc The Ex-related marking can also be printed on the enclosed label. Standards EN :2012+A11:2013, EN :2014 Protection by enclosure "tc" Some of the information in this instruction manual is more specific than the information provided in the datasheet. The corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet. Laws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again. The maximum permissible load current must be restricted to the values given in the following list. High load currents and load short-circuits are not permitted. Maximum operating voltage U Bmax The maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted. Maximum permissible ambient temperature T Umax dependant of the load current I L and the max. operating voltage U Bmax. Information can be taken from the following list. 44 C (111.2 F) 45 C (113 F) 51 C (123.8 F) 55 C (131 F) 56 C (132.8 F) Protection from mechanical danger The sensor must not be exposed to ANY FORM of mechanical danger. Protection from UV light The sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS Do not attach the nameplate provided in areas where electrostatic charge can build up. Connections for external wire Terminal connection: Minimum conductor cross-section: 0.5 mm 2, maximum conductor cross-section: 2.5 mm 2. The ends of the conductor must be provided with cable sleeves. If cable glands are required for the installation then the following points must be observed: The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the application. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application. The plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: "WARNING - DO NOT SEPARATE WHEN ENERGIZED". With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted) 5

SERIES 54 Inductive Proximity Sensor

SERIES 54 Inductive Proximity Sensor SENSOR FEATURES > 2-wire DC sensor with minimum off-state current > ATEX-approval for zone 2 and zone 22 > High temp, UV, salt water resistant > Rugged metal base > IP66/67/69K > High impact protection

More information

SERIES 54 PROXIMITY SENSORS

SERIES 54 PROXIMITY SENSORS SERIES 54 PROXIMITY SENSORS Technical Manual BRAY.COM THE HIGH PERFORMANCE COMPANY TABLE OF CONTENTS GENERAL SERVICE DC 3-wire PNP 540021-71104533... S1-1 DC 2-wire 540022-71104533... S2-1 DC 2-wire +

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG10D-P and BExBG15D-P Flameproof Xenon Beacons For use in Flammable Gas and Dust Atmospheres BExBG10D-P / BExBG15D-P 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE

More information

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to General Notes Relating to Pepperl+Fuchs Product Information. Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual and Installation Instructions Segurança PSB Heating System Cold applied connection technology Compulsório Type 27-1680-...0/...

More information

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid coil for control in potentially explosive areas Type BZ Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used

More information

Type Z & Ex pz purge and pressurization system

Type Z & Ex pz purge and pressurization system Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401 > As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp

More information

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX ATEX Type Certification marking for type L1X-EX, T1X-EX, T2X-EX Type of protection "d" explosion-proof enclosure Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual/Installation Instructions Segurança MSB/HSB Heating System Cold applied connection technology Compulsório Type 27-1.80-...0/...

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

EVZ Series (Small body) Explosion protected luminaire Operating Instructions EVZ Series (Small body) Explosion protected luminaire Operating Instructions Cooper Crouse-H i n d s Cooper E l ec t ron i c T ec h n ol og i es ( S h a n g h a i ) Co., L t d. No. 955 Shengli Road, East

More information

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4 1. Introduction: This instruction manual contains important information regarding the safety instructions, installation, operation, maintenance and storage of the Guardbox limit switch boxes. The limit

More information

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m Characteristics Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m Product availability : Stock - Normally stocked in distribution facility Price* : 98.00 USD Main Range of product Sensor type

More information

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions Segurança TC RU C-DE.ГБ06.B.00230 OCP 0004 Compulsório INMETRO Operation Manual/Installation Instructions Segurança PSB Heating System Heat shrink technology Compulsório Type 27-1680-...0/... OCP 0004

More information

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L Temperature Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L WIKA data sheet TE 65.12 for further approvals see page 2 Applications Chemical industry Petrochemical industry

More information

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-PSG3S/3GD ATEX category II 3 G, Ex zone 2 ATEX category II 3 D, Ex zone 22 For T-groove cylinders without mounting accessories Optional accessories for mounting on other cylindrical housings. One-hand mounting possible

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

Capanivo Series CN 4000

Capanivo Series CN 4000 Capanivo Series CN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de Scope of this instruction

More information

Assembly. Trunk IN + - S U, I U, I. Spur 1

Assembly. Trunk IN + - S U, I U, I. Spur 1 FieldBarrier FD0-FB-Ex.* Features Assembly outputs Ex ia IIC FieldBarrier in Zone /Div. Instruments in Zone 0.../Div. Short circuit current limitation per output For FOUNDATION Fieldbus H and PROFIBUS

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Instructions...3 4 Conformity to Standards...3 5 Intended Field of Application...3

More information

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m Characteristics capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 159.00 USD Main Range

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12 Characteristics Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name Pressure

More information

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves Complete modular designed accessory program More for less - optimal configuration costs Easy maintenance and commissioning

More information

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444 Operation Instructions (translation) Explosion Protection Explosion protection is one option and is marked on the ex-type plate on the solenoid drive. The actuators and the associated solenoid controllers

More information

Instruction Manual. Ex-Time 40 / 50

Instruction Manual. Ex-Time 40 / 50 Instruction Manual Ex-Time 40 / 50 Contents 1. Introduction 13 2. Safety Advice 13 3. Faults and Damage 13-14 4. Safety Regulations 14 5. Ex-Data 14-15 6. Technical Data 15-16 7. Use and Application /

More information

YFC. Limit switch. Ex d. 24 operating head types

YFC. Limit switch. Ex d. 24 operating head types Ex d YFC Limit switch 24 operating head types - Group IIC - Zone 1, 2, 21, 22 - Aluminium alloy - Easy installation, wiring and maintenance - Durable and safe over time Fastening system Earth screw RAL735

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Surface thermocouple Model TC50

Surface thermocouple Model TC50 Temperature Surface thermocouple Model TC50 WIKA data sheet TE 65.50 for further approvals see page 2 Applications To measure surface temperatures on flat surfaces or pipes, in both laboratory and industrial

More information

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 , IECEx EPS 16.0030X Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /.. d.o.o. tel. 049 222 900, fax 049 426 450 e-mail: tepex@tepex.hr www.tepex.hr USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE 0403.24/.. No: TEPEx.RS.077 Rev : 0 Date: 02.2016. CONTENT 1. Manufacturer

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/2 and 4/2 directional seat valves with solenoid actuation RE 22049-XN-B2/08.12 Replaces: 07.10 Type M-.SED 6...XN... Size 6 Component series 1X Maximum operating pressure 350 bar Maximum flow 25

More information

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13 Gamma Floodlight IP66/67 The Gamma is a high output LED floodlight is designed for use in Zone 1 & 21 hazardous areas. The compact design and flexible mounting allows the Gamma to also be used as a lowbay.

More information

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL Subject to change without prior notice TUM5461 REV. B 20.07.2017 IMPORTANT Read this instruction carefully before installing the product

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 Equipment: Manufacturer: Type: ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION

More information

ILED Dorado. User Manual

ILED Dorado. User Manual 10NM U-code Medium Intensity Obstruction Light Helideck Status Light 15NM U-code Contents 1. Safety... 3 2. Warranty... 3 2.1 General... 3 2.2 Life span... 3 3. Type plate... 4 4. Product Description...

More information

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures Mercmaster Series Luminaires LIGHTING: ENCLOSED AND GASKETED AREA /INDUCTION Applications Enclosed and gasketed fixtures suitable for use in: Marine and wet locations A wide range of industrial, chemical

More information

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 , IECEx PTB 14.0049X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection

More information

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to General Notes Relating to Pepperl+Fuchs Product Information. Type Z & Ex pz purge and pressurization system Features 100% automatic purge and pressurization system including purging, temperature and leakage control, alarming and system power Third party approvals

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations

Control Stations & Switches: Control Stations Increased Safety Unicode 2 Series: Pre-drilled Control Stations Unicode 2 Series: Pre-drilled Control Stations Polamide U43W211 Polyester U23W211 Compliance Data: ATEX IEC and IECEx (Polyester): Stainless Steel U62W229 Aluminum U83W211 ATEX IEC / IECEx CE Ex de IIC

More information

International approvals.

International approvals. E X - P L U G A N D R E C E P T A C L E A to 25 A plugs and receptacles plastic version for Zone 2 A good connection Providing electrical energy there, where it is most needed even in hazardous areas for

More information

Thermocouple Without thermowell Model TC10-H

Thermocouple Without thermowell Model TC10-H Temperature Thermocouple Without thermowell Model TC10-H WIKA data sheet TE 65.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors Bearing

More information

Safety Standards. Model Number:

Safety Standards. Model Number: Highlights & Features RoHS Compliant Relay alarm indirection Built-in 2 channel DC OK signal Caused by rugged handing Conformal coating on PCBA to protect against chemical and dust pollutants Class I,

More information

A good connection. International approvals.

A good connection. International approvals. E X - P L U G S A N D R E C E P T A C L E S A to A Plastic version for Zone and Zone A good connection Providing electrical energy there, where it is most needed even in hazardous areas for the Zones,,

More information

Cable resistance thermometer Model TR40

Cable resistance thermometer Model TR40 Electrical temperature measurement Cable resistance thermometer Model TR40 WIKA data sheet TE 60.40 for further approvals see page 2 Applications For direct installation into the process Machine building

More information

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L Temperature Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L WIKA data sheet TE 60.12 for further approvals see page 2 Applications Chemical industry Petrochemical

More information

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Without thermowell Model TR10-H Temperature Resistance thermometer Without thermowell Model TR10-H WIKA data sheet TE 60.08 for further approvals see page 2 Applications For direct installation into the process Machine building Motors

More information

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T**

11mm Slot Label S1 = 162, S2 = 170, S3 = 250, S4 = 305, S5 = 330, S6 = 410, S7 = 490, S8 = 570, S9 = 650. Maximum Power Dissipation (Watts) T** T** Assembly Instructions for: S1 Assembly to S Junction Instructions Boxes for: MS1 to MS Junction Boxes Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully before commencing

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX)

Product Overview. Rotary Encoders for Potentially Explosive Atmospheres (ATEX) Product Overview Rotary Encoders for Potentially Explosive Atmospheres (ATEX) December 2013 Rotary encoders for use in potentially explosive areas Introduction There are many types of applications in industry

More information

Terminal Boxes in Stainless Steel SLS**.T

Terminal Boxes in Stainless Steel SLS**.T Features Variant options Stainless steel enclosures Suitable for installation in Zones 0, 1, 2, 21 and 22 Certified Ex e, Ex ia and Ex tb 6 enclosure size options Various terminal and cable gland configurations

More information

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12 Characteristics Pressure sensors XMLR -1 bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output

More information

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components

More information

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2 Fieldbus Segment Protector Features Assembly 4... 10 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur Segment Protector in Zone 2/Div. 2 Instruments in Zone

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series BASIC 90 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC ow profile

More information

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX ) Publication# 03revA Table of Contents Publication# 03revA Table Of Contents...

More information

Emergency Luminaire with LED Series EXLUX 6409/1

Emergency Luminaire with LED Series EXLUX 6409/1 > Emergency luminaire for wall, ceiling, pendant or pole installation > Latest LED technology with a high luminous efficacy and a long service life > Central locking system > Weekly functional test > Annually

More information

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter

More information

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Float Flow Meter / Monitor. Model: SWK Operating Instructions for Float Flow Meter / Monitor Model: SWK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 4 6. Use in Hazardous

More information

Measuring insert for process resistance thermometer

Measuring insert for process resistance thermometer Electrical temperature measurement Measuring insert for process resistance thermometer Model TR12-A WIKA data sheet TE 60.16 for further approvals see page 2 Applications Replacement measuring insert for

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 54 V SEV for

More information

Thermocouple For additional thermowell Model TC10-B

Thermocouple For additional thermowell Model TC10-B Temperature Thermocouple For additional thermowell Model TC10-B WIKA data sheet TE 65.02 for further approvals see page 2 Applications Machine building, plant and vessel construction Energy and power plant

More information

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series BASIC 50 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow profile

More information

Compact temperature switch Model TCS

Compact temperature switch Model TCS Mechatronic temperature measurement Compact temperature switch Model TCS WIKA data sheet TV 31.64 Process Compact Series Applications Temperature monitoring and control of processes Safety-critical applications

More information

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content EX-AZM 161 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information

More information

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-... Operating Instructions for Paddle Flow Monitor Model: PSR-..., PSE-... 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 4 4. Regulation Use... 4 5. Operating Principle... 5 6. Use

More information

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4 18 NPT - 24VDC ma - NPN - M12 Characteristics Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC - 4..20 ma - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short

More information

Compact Sheet-Steel Light Fittings Series 6114/1

Compact Sheet-Steel Light Fittings Series 6114/1 > As 1- or 3-lamp version > Versions Pendant fitting Wall-mounting fitting Flush mounted fitting > Powder-coated steel or stainless steel > Central lock > All pole disconnection via NC switch in positive

More information

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12 Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 0..10 V - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name

More information

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal... Safety sensor 7 Disassembly and disposal 7.1 Disassembly....5 7.2 Disposal...5 8 Appendix 8.1 Wiring example...6 Operating instructions.............pages 1 to 8 Original 9 EU Declaration of conformity

More information

Control Buttons / Switches for Panel Mounting Series 8003

Control Buttons / Switches for Panel Mounting Series 8003 www.stahl.de > Different actuators pushbutton mushroom pushbutton mushroom stay-put button mushroom stay-put button with key lock key-operated button key-operated switch > 2 contact elements > Spring clamp

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Change from two to one column Multi barriers Change from one to two columns

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6402/2 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250, Assembly Instructions for junction boxes type: Assembly Instructions for: S1 to S / SFI1 to SFI / SFE1 to SFE S1 to S Junction Boxes MS1 to MS Junction Boxes IMPORTANT: This document should be read carefully

More information

HTSB system System overview

HTSB system System overview HTSB system System overview Easy planning of heating circuits Simple installation on site Wide operating temperature range The BARTEC HTSB heating system covers a wide range of applications in trace heating.

More information

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series EM converter EM converter BASIC 200 V BASIC series Product description lighting Driver for manual testing For modules with a forward voltage of 50 200 V ow profile casing (21 x 30 mm cross-section) For

More information

Pneumatic control unit for decentralized automation of ELEMENT process valves

Pneumatic control unit for decentralized automation of ELEMENT process valves 890 Pneumatic control unit for decentralized automation of ELEMENT process valves Type 890 can be combined with... Compact design Integrated pilot valve with manual override Integrated control air routing

More information

Emergency lighting units EM converterled

Emergency lighting units EM converterled EM converter EM converter BASIC icd/imh 250 V BASIC series Product description lighting Driver for manual testing For self-contained emergency lighting For modules with a forward voltage of 50 250 V ow

More information

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22. PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22 News 08 PROTECT SRB s Safety relay modules with intrinsically safe monitoring

More information

LED Linear Luminaire Series EXLUX 6402

LED Linear Luminaire Series EXLUX 6402 > Latest LED technology with a high luminous efficacy and a long service life > As pendant light fitting or side entry lamp > Central locking > All-pole disconnection by means of an N/C switch when the

More information

M-0. M-0... series control, monitoring and signalling devices. Ex e

M-0. M-0... series control, monitoring and signalling devices. Ex e M-0 The new Cortem M-0 series control, monitoring and signalling devices are installed as external accessories on '' enclosures and boards used in any industrial environment where an explosive atmosphere

More information

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface 9700 NAMUR / & / way spool valves electromagnetic actuated, indirectly controlled G /, / NPT, NAMUR Interface For single and double acting actuators / or / way function in one valve Easily interchangeable

More information

Sense7-series Non-contact coded safety switch

Sense7-series Non-contact coded safety switch Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please

More information

EX-REPAIR AND MAINTENANCE RECEPTACLES

EX-REPAIR AND MAINTENANCE RECEPTACLES EX-REPAIR AND MAINTENANCE RECEPTACLES A 3 A plugs and receptacles plastic version for zones, 2, 2 and 22 For maintenance, repair and upgrading work, appliances such as drills, welding transformers, hand