Certificate of Compliance

Size: px
Start display at page:

Download "Certificate of Compliance"

Transcription

1 Certificate of Compliance Certificate: Master Contract: Project: Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, Germany Attention: Mr. Michael Schröck The products listed below are eligible to bear the CSA Mark shown Issued by: Jean-Claude Chow Jean-Claude Chow PRODUCTS CLASS INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Magnetic CLASS INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Miscellaneous Part A (Class ): ET 200S Motor Starter, Size S0 Magnetic starter, Class 10 or 20 programmable overload, control circuit 24 Vdc: Type 3RK B1.-.AA2, -.AA3 or -.AA4, rated 600 Vac, 3-ph, 16 A max FLA; Type 3RK B1.-.AB4, rated 600 Vac, 3-ph, 16 A max FLA (see Note 5). Accessories: Terminal Modules, Type 3RK1903, rated 600 Vac, 50 A; Control Modules, Types 3RK1903-0CH00 and 3RK1903-0CH The type designation may be completed with suffixes. 2. Certified as component for use only in Certified equipment where the acceptability of combination is to be determined by CSA International. 3. To be used in combination with this manufacturer Type 3RK1903 Power Module. DQD 507 Rev Page: 1

2 Certificate: Master Contract: Project: Suitable for Group Fusing application: 10,000 rms symmetrical amperes max at 600 V and 50, 000 rms symmetrical amperes max at 480V when protected by a 200 A max Fuse. 5. ET 200S Motor Starter Type 3RK B1.-.AB4 is rated 600 Vac, 3-ph, max FLA: 16 A, horizontal mounting at surrounding air temp. 40 C; 16 A, vertical mounting at surrounding air temp. 55 C; 15.2 A, vertical mounting with distance module 3RK1903-0CD00 at surrounding air temp. 60 C; 14 A, vertical mounting at surrounding air temp. 60 C. Part B (Class ): ET 200S Motor Starter, Size S0 Soft starter, Class 10 overload, control circuit 24 V dc: Type 3RK B2.-AA2, -.AA3 or -.AA4, rated 600 V, 16 A max FLA; Type 3RK B2.-.AB4, rated 600 Vac, 3-ph, 16 A max FLA (see Note 5). Accessories: Terminal Modules, Type 3RK1903, rated 600 Vac, 50 A; Control Modules, Types 3RK1903-0CH00 and 3RK1903-0CH The type designation may be completed with suffixes. 2. Certified as component for use only in Certified equipment where the acceptability of combination is to be determined by CSA International. 3. To be used in combination with this manufacturer Type 3RK1903 Power Module. 4. Suitable for Group Fusing application: 10,000 rms symmetrical amperes max at 600 V and 50, 000 rms symmetrical amperes max at 480V when protected by a 200 A max Fuse. 5. ET 200S Motor Starter Type 3RK B2.-.AB4 is rated 600 Vac, 3-ph, max FLA: 16 A, horizontal mounting at surrounding air temp. 40 C; 16 A, vertical mounting at surrounding air temp. 55 C; 15.2 A, vertical mounting with distance module 3RK1903-0CD00 at surrounding air temp. 60 C; 14 A, vertical mounting at surrounding air temp. 60 C. APPLICABLE REQUIREMENTS CSA-C22.2 No Industrial Control Equipment DQD 507 Rev Page: 2

3 Descriptive Report and Test Results MASTER CONTRACT: Edition 1: Edition 2: Edition 3: Edition 4: Edition 5: February 11, 2002; Project Montreal Issued by M. Legault, Eng. July 02, 2002; Project Montreal Issued by M. Legault, Eng. January 07, 2003; Project Montreal Issued by M. Legault, Eng. June 07, 2006; Project Montreal Issued by M. Legault, Eng. June 8, 2011; Project Montreal Issued by J.-C. Chow, Eng. Report pages reissued Illustration 8 and Test Report No TE-U (26 Pages) added Contents: Certificate of Compliance - Pages 1 to 2 Supplement to Certificate of Compliance - Page 1 Description and Tests - Pages 1 to 13 Att1 Figures - Fig. Nos. 1, 2, 2A, 3 to 8 Att2 Illustrations - Ill. Nos. 1 to 8 Att3 Test Reports - Nos W-u (18 Pages), 01083W-x (17 Pages); Nos W-u (29 Pages), 10056TE-U (26 Pages) PRODUCTS CLASS INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Magnetic CLASS INDUSTRIAL CONTROL EQUIPMENT - Motor Controllers - Miscellaneous Part A (Class ): ET 200S Motor Starters, Size S0 Magnetic starter, Class 10 or 20 programmable overload, control circuit 24 Vdc: Type 3RK B1.-.AA2, -.AA3 or -.AA4, rated 600 Vac, 3-ph, 16 A max FLA; Type 3RK B1.-.AB4, rated 600 Vac, 3-ph, 16 A max FLA (see Note 5). Accessories: Terminal Module, Type 3RK1903, rated 600 Vac, 50 A; Control Modules, Types 3RK1903-0CH00 and 3RK1903-0CH10. This report shall not be reproduced, except in full, without the approval of CSA International. 865 Ellingham Street, Pointe-Claire, Quebec, Canada H9R 5E8 Telephone: Fax:

4 Page No: 2 1. The type designation may be completed with suffixes. 2. Certified as component for use only in Certified equipment where the acceptability of combination is to be determined by CSA International. 3. To be used in combination with this manufacturer Type 3RK1903 Power Module. 4. Suitable for Group Fusing application: 10,000 rms symmetrical amperes max at 600 V and 50, 000 rms symmetrical amperes max at 480V when protected by a 200 A max Fuse. 5. ET 200S Motor Starter Type 3RK B1.-.AB4 is rated 600 Vac, 3-ph, max FLA: 16 A, horizontal mounting at surrounding air temp. 40 C; 16 A, vertical mounting at surrounding air temp. 55 C; 15.2 A, vertical mounting with distance module 3RK1903-0CD00 at surrounding air temp. 60 C; 14 A, vertical mounting at surrounding air temp. 60 C. Part B (Class ): ET 200S Motor Starters, Size S0 Soft starter, Class 10 overload, control circuit 24 V dc: Type 3RK B2.-AA2, -.AA3 or -.AA4, rated 600 V, 16 A max FLA; Type 3RK B2.-.AB4, rated 600 Vac, 3-ph, 16 A max FLA (see Note 5). Accessories: Terminal Module, Type 3RK1903, rated 600 Vac, 50 A; Control Modules, Types 3RK1903-0CH00 and 3RK1903-0CH The type designation may be completed with suffixes. 2. Certified as component for use only in Certified equipment where the acceptability of combination is to be determined by CSA International. 3. To be used in combination with this manufacturer Type 3RK1903 Power Module. 4. Suitable for Group Fusing application: 10,000 rms symmetrical amperes max at 600 V and 50, 000 rms symmetrical amperes max at 480V when protected by a 200 A max Fuse. 5. ET 200S Motor Starter Type 3RK B2.-.AB4 is rated 600 Vac, 3-ph, max FLA: 16 A, horizontal mounting at surrounding air temp. 40 C; 16 A, vertical mounting at surrounding air temp. 55 C; 15.2 A, vertical mounting with distance module 3RK1903-0CD00 at surrounding air temp. 60 C; 14 A, vertical mounting at surrounding air temp. 60 C. APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No. 0-M91 - General Requirements - Canadian Electrical Code, Part II CSA-C22.2 No Industrial Control Equipment

5 Page No: 3 MARKINGS Submittor s name or tradename Siemens and/or CSA File LR and/or CSA Master Contract , type designation, electrical ratings and CSA Monogram appear on an adhesive label and/or printed on the cover in a permanent manner. The following or equivalent wording is permanently marked on the device: GROUP FUSING, SHORT CIRCUIT RATING: 10 ka, 600 V MAX. AND 50 ka, 480 V MAX WHEN PROTECTED BY A 200 A MAX FUSE. The following or equivalent wording is permanently marked on the device: SURROUNDING AIR TEMPERATURE 60 C, when ET200S is mounted vertical and For all versions of Standard Motor Starter For 3 A version (3RK1301-0A) of Fail safe Motor Starter For 8 A version (3RK1301-0B) of Fail safe Motor Starter, Distance module is demanded or if current is down rated to 75 % For 16 A version (3RK1301-0C) of Fail safe Motor Starter, if current is down rated to 75% and Distance module is demanded or if current is down rated to 50% SURROUNDING AIR TEMPERATURE 50 C, when ET200S is mounted vertical and For 8 A version (3RK1301-0B) of Fail safe Motor Starter For 16 A version (3RK1301-0C) of Fail safe Motor Starter, Distance module is demanded SURROUNDING AIR TEMPERATURE 40 C, when ET200S is mounted vertical and For 16 A version (3RK1301-0C) of Fail safe Motor Starter SURROUNDING AIR TEMPERATURE 40 C, when ET200S is mounted horizontal and For all versions of Standard or Fail safe Motor Starter The following or equivalent wording is permanently marked to terminal module type 3RK1903 only: USE 75 C COPPER WIRE ONLY ALTERATIONS The markings are in accordance with the MARKINGS paragraph above. FACTORY TESTS The equipment, at the conclusion of manufacture and before shipment, shall withstand for one minute, without breakdown, the application of twice rated voltage plus 1000 V between live parts and metal parts, which may be grounded, on a basis of at least 3% of the daily production intended to bear the CSA Monogram. As an alternative, a potential 20 per cent higher may be applied for one second. The factory test may be made at existing room temperatures. As an alternative, method based on IEC 410 and in accordance with submittor s ISO 9001 Quality program. Warning: These tests may present a hazard of injury to personnel and/or property and should only be performed by persons knowledgeable of such hazards and under conditions designed to minimize the possibility of injury.

6 Page No: 4 SPECIAL INSTRUCTIONS FOR FIELD SERVICES 1. Component Substitution a) Critical components (those identified by mfr name, cat no) are not eligible for substitution without evaluation and report updating. b) Component descriptions marked with the identifier (INT) are the only components that are eligible for substitution at the factory. c) Substitution of a CSA Certified component with a component Certified or Listed by another organization may result in annual sample pickup and Conformity Testing. d) Substitution of a Certified or Listed component with a component that is Recognized or Accepted is not permitted without evaluation and report updating. COMPONENT SPECIAL PICKUP None.

7 Page No: 5 DESCRIPTION 1. The term (INT), following the component name, denotes a certified component that can be replaced by another CSA Certified component or one certified by another certification organization (recognized by OSHA/accredited by SCC), for the same application, provided that it has an equivalent rating, configuration (size, orientation, mounting) and that applicable minimum creepage and clearance distances are maintained from live parts to bonded metal parts and secondary parts. 2. The term (CT), following the component name, denotes a component that is subject to periodic retesting unless evidence of re-testing equivalent to the CSA program is available. Nomenclature Breakdown 3RK A B AA2 I II III IV V VI VII VIII IX I II III IV V VI VII VIII IX Basic Type 3RK13 Motor starter Type of interface 0 Profibus-DP Product Type 1 Motor Starter ET200S Setting range 0A 0.3 up to 3 A, Class 10 or 20 0B 2.4 up to 8 A, Class 10 or 20 0C 2.4 up to 16 A, Class 10 or 20 Type of enclosure B Open type Type of function 1 Electromechanical starter 2 Soft starter Version 0 High Feature Standard Motor Starter 3 High Feature Fail safe Motor Starter Mode of operation 0 Direct-on-line starter 1 Reversing starter Model AA2 Standard model with interface for extension modules and electronic inputs are provided AA3 Same as AA2 except an interface for local control is provided AA4 Same as AA3 with new firmware release AB4 Same as AA4 with new firmware release

8 Page No: 6 3RK A. 00 I II III IV V I II III IV V Accessories Type 3RK1903 For ET200S Size S0 Motor starter Accessory groups 0 Accessories for motor starters 2 Accessories for power supply 3 Accessories for Fail safe motor starters Type of Accessories A Terminal module B Power module C Control module D Power / Extension module Model Design. Model design Type of Terminal Module 00 With supply connection 10 Without supply connection

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2049843 (LR 12730-263) Master Contract: 165071 Project: 2460955 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention:

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1588199 (LR 12730-233) Master Contract: 165071 Project: 1588199 Date Issued: 2004/11/03 Issued to: Siemens AG A&D CD CC TS2 Werner-von-Siemens-Strasse 48 Amberg,

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Mechanically Operated and Solid-state

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance (012730_C_000) Issued to: Siemens AG DF CP R&D VC 2 WernervonSiemensStrasse 48 Amberg, 92224 GERMANY The products listed below are eligible to bear the CSA Mark shown Issued by:

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D V 3 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED-CASE AND CIRCUIT BREAKER ENCLOSURES

More information

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices Type No 3RB2 followed by 0 or 1 followed

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E 1512 E47705 Report Reference E4770519970821 15OCTOBER12 Issued to: SIEMENS AG DF CP R&D V 3 WERNERVONSIEMENSSTRASSE 48 9 AMBERG GERMANY This is to certify that representative samples of MOTOR CONTROLLERS,

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been

More information

Prüf-Nr./Q-Nr.: Certificate No.: Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: rech. Daten: Specification: U = 500V, U" = 400V l"= 12 A

Prüf-Nr./Q-Nr.: Certificate No.: Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: rech. Daten: Specification: U = 500V, U = 400V l= 12 A SIEMENS Prüf-Nr./Q-Nr.: Certificate No.: Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: 2267 a I la CE PRM CP SR 1 / Drutschmann Amberg ras: 2010-12-22 Date: Test Summary Pri,ibescheinigung

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices USL, CNL - Type No. 3RU1146 or 3RU2146 followed

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

Ref No: N Date: December 7, Fuseholder Assemblies No. 2. Call us today! See Attachment 1 for Effective Dates.

Ref No: N Date: December 7, Fuseholder Assemblies No. 2. Call us today! See Attachment 1 for Effective Dates. Ref No: N07-094 Date: December 7, 2007 Fuseholder Assemblies No. 2 See Attachment 1 for Effective Dates. Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272

More information

JDDZ.E Cartridge Fuses, Nonrenewable. Cartridge Fuses, Nonrenewable

JDDZ.E Cartridge Fuses, Nonrenewable. Cartridge Fuses, Nonrenewable Seite 1 von 6 Page Bottom JDDZ.E258218 Cartridge Fuses, Nonrenewable Cartridge Fuses, Nonrenewable See General Information for Cartridge Fuses, Nonrenewable SIEMENS AG I BT LV POSTFACH 10 09 53 93009 REGENSBURG,

More information

Certificate of Compliance

Certificate of Compliance FF0 002 Certificate of Compliance Issued to: Rotork Controls Inc. 675 Mile Crossing Blvd Rochester, NY 14624 USA Attention: Matt Cogill The products listed below are eligible to bear the CSA Mark shown

More information

Low-Peak 600V Class RK1

Low-Peak 600V Class RK1 LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1310361 Master Contract: 189664 Project: 2257095 Date Issued: 2010/02/12 Issued to: Bryan Donkin RMG Canada Limited 50 Clarke Street South Woodstock, ON N4S 0A8 Canada

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1156566 (111752-1) Master Contract: 188586 Project: 2115390 Date Issued: 2008/12/11 Issued to: Autoflow 15915 South San Pedro St Gardena, CA 90248 USA Attention:

More information

File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd.

File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd. File E63614 Project 01SC10795 January 10, 2002 REPORT ON COMPONENT - MOTOR CONTROLLERS, MAGNETIC Fujitsu Takamisawa Component Ltd. Nagano, Japan Copyright 2001 Underwriters Laboratories Inc. Underwriters

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Elevator Equipment No. 24 Effective Date: January 1, 2019 Date: May 3, 2018 Apply Before September 1, 2018 Announcing: Withdrawing of TIL CSA D-11B and Publication of

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Certificate of Compliance

Certificate of Compliance FF0001 Certificate of Compliance Certificate: 1345550 Issued to: Eaton Electric Ltd. Great Marlings Butterfield, Luton Bedfordshire LU2 8DL United Kingdom Attention: Mr. Peter Rigling The products listed

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1345550 (LR 36637) Master Contract: 152423 Issued to: Measurement Technology Limited Great Marlings Butterfield Luton, Bedfordshire LU2 8DL United Kingdom Attention:

More information

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. File E171806 Project 04CA46856 October 28, 2004 REPORT on MANUAL MOTOR CONTROLLERS Sontheimer Elektroschaltgerate GmbH Nuremberg, Germany Copyright 1998 Underwriters Laboratories Inc. Underwriters Laboratories

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

moog MSD Servo Drive UL-Certification MSD Servo Drive product range MSD Servo Drive UL-Certification MSD Servo Drive product range 2 UL-Certification Id No : CC36842-001, Rev. 1.0 Date: 05/2017 We reserve the right to make technical changes. The content of our documentation

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1132623 (LR 82598) Master Contract: 160686 Project: 2567317 Date Issued: November 5, 2012 Issued to: Endress + Hauser Flowtec AG Kagenstrasse 7 Reinach, Basel Land

More information

Letter of Attestation

Letter of Attestation FF01 Letter of Attestation Master Contract: 162842 Report: 1662646 Project: 1662646 Class No. 7861-37 CSA International has completed the following custom testing for Ferraz Shawmut Inc. 374 Merrimac St.

More information

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL File E135493 Project 92ME10175 February 6, 1992 REPORT on COMPONENT - POWER SUPPLIES For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL Vicor Corp. Andover, MA Copyright 1992 Underwriters

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses Technical Data1019 Supersedes July 2013 Fusetron FRN-R Class RK5 250Vac/125Vdc Catalog symbols: FRN-R-_ (non-indicating) FRN-R-_ID (indicating) Description: Eaton Bussmann series advanced protection, energy

More information

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions. Models beginning with MO, MK, 7B, 6S, 6F or 5B The Mini Meter Product Description Technical Specifications Installation Instructions February 28 th, 2013 1. Product Description...2 1.1 General Description...2

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70054084 Issued to: Emerson - Rosemount, Micro Motion Inc. 12001 Technology Dr. Eden Prairie, Minnesota 55344 USA Attention: Paul Schilke The products listed below

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses Technical Data 6 Supersedes August 2015 Low-Peak LPJ Class J 600Vac/Vdc, 1-60A, Catalog symbol: LPJ-(amp)SP (non-indicating) LPJ-(amp)SPI (indicating) Description: Bussmann series Ultimate protection LPJ

More information

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2 TABLE OF CONTENT 1. Scope... 2 2. Reference Documents.. 2 3. Material and Components...... 2 4. Design and Construction..... 2 5. Rating.. 2 6. Performance and Test Descriptions. 2 7. Test Requirements

More information

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FRNR400 400A 250V TD Class RK5 Dual Elem Fuse-Fusetron Catalog Number Manufacturer Description Weight per unit Product

More information

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

Certi 堵脝 cation Record

Certi 堵脝 cation Record Certi 堵脝 cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 214 INDUSTRIAL CONTROL EQUIPMENTMotor Controllers Magnetic

More information

REPORT NO INSPECTION, TEST AND EVALUATION OF. Interlock Kits SUBMITTED TO MASTER ELECTRICAL SERVICES 3107 LANVALE AVENUE RICHMOND, VA 23230

REPORT NO INSPECTION, TEST AND EVALUATION OF. Interlock Kits SUBMITTED TO MASTER ELECTRICAL SERVICES 3107 LANVALE AVENUE RICHMOND, VA 23230 : November 16, 2009 REPORT NO. 52431-01 INSPECTION, TEST AND EVALUATION OF Interlock Kits SUBMITTED TO MASTER ELECTRICAL SERVICES 3107 LANVALE AVENUE RICHMOND, VA 23230 A WYLE LABORATORIES, INC. WYLE is

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

Ref No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2

Ref No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2 Ref No: 95-013 Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2 To: Manufacturers of Industrial Control Equipment Subject: Publication of Technical Information Letter (T.I.L.) No D-21 on Interim

More information

MS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description

MS303DS MS-303 3P Man CNT Only. Features. Dimensions and Weight. Long Description MS303DS MS-303 3P Man CNT Only Leviton Manufacturing Catalog Number Manufacturer Description Weight per unit Product Category Features action TPST actuator Toggle amperage rating 30 connection Back Wired;Side

More information

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit

More information

Sicherungslose Verbraucherabzweige Leistungsschalter 3VA. fuseless load feeder circuit breaker

Sicherungslose Verbraucherabzweige Leistungsschalter 3VA. fuseless load feeder circuit breaker Nummer: Number: 3343 Bestätigung Confirmation Sicherungsloser Motorabzweig Zuordnungsart 1 2 nach IEC 60947-4-1 bei AC 400 V Fuseless Load Feeder Coordination type 1 2 according IEC 60947-4-1 at AC 400

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

N0N A 250V One-Time Class H Fuse

N0N A 250V One-Time Class H Fuse 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 AllenWatson@elliottelectric.com N0N 250V One-Time Class H Fuse Catalog Number Manufacturer Description Weight per unit

More information

BUSWAY Low Voltage (Pow-R-Flex)

BUSWAY Low Voltage (Pow-R-Flex) BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

Three-Phase Soft Starters

Three-Phase Soft Starters Submittal Data English Language/IP Units 04/14 Contact Information: Hyper Engineering, Pty. Ltd. 4 / 14 Ralph Black Dr Wollongong Nth, NSW 2500 AUSTRALIA www.hypereng.com sales@hypereng.com (+61) 2 4229

More information

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.

More information

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors Type LKT Power Factor Correction s LKT E337088 Features that matter: Handles continuous current up to 2.25 / 2.7 times rated current Withstands inrush current up to 375 / 450 times rated current Self-healing type,

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Rotary Disconnect Switches, Bulletin 194R

Rotary Disconnect Switches, Bulletin 194R ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en Connect - Contact - Control 3 Contactors CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en 2 CL1115/02, CL1215/02, CL1315/02 1, 2 and 3

More information

DART Charger Product Description, Information and Specification

DART Charger Product Description, Information and Specification g Digital Energy DART Charger Product Description, Information and Specification Document Number : PRPI-029 Version : 1.00 Revision : 2 Date : 03.02.11 Classification: NOTICE OF COPYRIGHT & PROPRIETARY

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): COVER PAGE FOR TEST REPORT Power Supplies for Information Technology Equipment Including Electrical Business

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

4.1. Definite Purpose Contactors and Starters. Contents

4.1. Definite Purpose Contactors and Starters. Contents . Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

An Urgent Bulletin from CSA Group

An Urgent Bulletin from CSA Group An Urgent Bulletin from CSA Group Occupational Health & Safety Products No. 115 (Replaces Occupational Health & Safety Products No. 92 Ref No. N16-002) Effective Date: July 1, 2019 Date: May 24, 2018 Apply

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

Harmonization of IEC and North American Safety Standards

Harmonization of IEC and North American Safety Standards Equipment SCCR made easy Harmonization of IEC and North American Safety Standards Dan Neeser Field Application Engineer Eaton s Bussmann Division DanRNeeser@Eaton.com Agenda UL 508C, UL 61800-5-1 and transition

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

10 S e r i e s PRESSURE SWITCH. features

10 S e r i e s PRESSURE SWITCH. features 10 S er i es 10 S e r i e s PRESSURE SWITCH features Tamper-Resistant Field Adjustment Adjustable Ranges from 4 to 7500 PSI (0,3 to 517,1 Bar) Choice of 7 Electrical Terminations 1-1/4" Diameter Height

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

Descriptive Report and Test Results

Descriptive Report and Test Results Descriptive Report and Test Results MASTER CONTRACT: 162505 Edition 1: Edition 2: Edition 3: Edition 4: Edition 5: Edition 6: 2000-01-05; Project 1136976 Cleveland; Issued by Valdis Udris, Reviewed by:

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Single & Three-Phase Soft Starters

Single & Three-Phase Soft Starters Submittal Data English Language/IP Units 11/13 Contact Information: Hyper Engineering, Pty. Ltd. 9000 Conservation Way Fort Wayne, IN 46809 www.hypereng.com sales@hypereng.com (877) 304-0724 Model Nomenclature

More information

Bussmann. Circuit Protection Solutions

Bussmann. Circuit Protection Solutions ussmann Circuit Protection Solutions ussmann Worldwide Circuit Protection Solutions World s leading supplier of fuses and fusible protection systems, ussmann continues its 88-year history of blazing new

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

Electrical Data Supplement

Electrical Data Supplement 48HC15to25NominalTons Single Package Rooftop Gas Heating/Electric Cooling Unit with Puronr (R---410A) Refrigerant Sizes: 17---28 Electrical Data Supplement FOR MODELS PRODUCED ON OR AFTER JULY 30, 2012

More information

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified POWER & ACTUATION ENCLOSED MOTOR PROTECTION CIRCUIT BREAKER & CONTACTOR ASSEMBLIES c3controls Series Enclosed Direct-On-Line (DOL) Starters come with all the features and benefits of our Series 330 Motor

More information

Equivalency Certificate (Approval issued by the competent authority of Canada)

Equivalency Certificate (Approval issued by the competent authority of Canada) Transport Canada Safety and Security Transports Canada Sécurité et sûreté Transportation of Dangerous Direction générale du transport Goods Directorate des marchandises dangereuses 330 Sparks Street 330,

More information