C E R T I F I C A T E O F C O M P L I A N C E
|
|
- Erin Kory Nelson
- 5 years ago
- Views:
Transcription
1 Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices USL, CNL - Type No. 3RU1146 or 3RU2146 followed by - 4D, -4E, -4F, -4H, -4J, -4K, -4L, or -4M followed by B or D followed by 0 or 1. Connecting support Type No. 3RU1946-3AA01 or 3RU2946-3AA01. Accessory Sealable Cover Type No. 3RV2908-0P (See following pages for additional information.) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: UL and CSA C22.2 NO Standard For Low-Voltage Switchgear and Controlgear - Part 1: General Rules, UL and CSA C22.2 NO Standard For Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor-Starters - Electromechanical Contactors and Motor-Starters. See the UL Online Certifications Directory at for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. Page 1 of 8
2 This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. General: These devices are open type 3-pole thermal overload relays. They are adjusted over a small range as indicated in the setting range table. They are provided with integral ambient compensated, nonreplaceable thermal trip features and are suitable for providing overload protection. The trip current is 125 percent of the FLA shown on dial. These devices may be provided with certified accessories of Type 3RU19.. or 3RU29.. including connecting support and electrical or mechanical remote reset. The connecting support Type No. 3RU1946-3AA01 or 3RU2946-3AA01 are connecting kits to have the 3RU1146 or 3RU2146 useable as stand-alone devices. Sealable Cover type 3RV2901-0P is suitable for the 3RU2146 devices described in this report. It is a sealable cover for the setting Knob. These devices are intended to be used in combination with the certified contactors Type 3TF and 3RT. Ratings: Tripping class 10 These devices are rated in terms of a range of trip and the corresponding adjustment dial calibration shown in the following list: Page 2 of 8
3 Short Circuit Ratings Short circuit ratings apply to both overload relays and overload relays with contactors. Standard Short Circuit Rating; 3RU1146, 3RU2146 (type 1 co-ordination): Overload from to (A) max. Fuse max. Fuse max. Short Voltage Relay Class K5 Class J Inverse Circuit RK1, RK5 Time CB CC 3RU..46-4D A 100 A 100 A 5 ka 600 V 3RU..46-4E A 125 A 125 A 5 ka 600 V 3RU..46-4F A 150 A 150 A 5 ka 600 V 3RU..46-4H A 200 A 200 A 5 ka 600 V 3RU..46-4J A 250 A 250 A 10 ka 600 V 3RU..46-4K A 300 A 300 A 10 ka 600 V 3RU..46-4L A 350 A 350 A 10 ka 600 V 3RU..46-4M A 400 A 400 A 10 ka 600 V Standard Short Circuit Rating; 3RU2146 (type 1 co-ordination): Overload from to (A) max. CB max. CB Short Voltage Relay 3VA51 3VA52 Circuit 3RU2146-4D A 100 A 5 ka 600 V 3RU2146-4E A 125 A 5 ka 600 V 3RU2146-4F A 150 A 5 ka 600 V 3RU2146-4H A 200 A 5 ka 600 V 3RU2146-4J A 250 A 10 ka 600 V 3RU2146-4K A 250 A 10 ka 600 V 3RU2146-4L A 250 A 10 ka 600 V 3RU2146-4M A 250 A 10 ka 600 V High-Capacity Short Circuit Ratings; 3RU1146 (in series with 3RT104 contactor) (type 1 co-ordination): Overload from to (A) max. Short Voltage Short Voltage Relay Inverse Circuit Circuit Time CB 3RU1146-4D A 25 ka 600 V 65 ka 480 V 3RU1146-4E A 25 ka 600 V 65 ka 480 V 3RU1146-4F A 25 ka 600 V 65 ka 480 V 3RU1146-4H A 25 ka 600 V 65 ka 480 V 3RU1146-4J A 25 ka 600 V 65 ka 480 V 3RU1146-4K A 25 ka 600 V 65 ka 480 V 3RU1146-4L A 25 ka 600 V 65 ka 480 V 3RU1146-4M A 25 ka 600 V 65 ka 480 V Page 3 of 8
4 High-Capacity Short Circuit Ratings, 3RU2146 (type 1 co-ordination): Overload from to (A) max. Fuse Short Voltage Relay Class J Circuit 3RU2146-4D A 100 ka 600 V 3RU2146-4E A 100 ka 600 V 3RU2146-4F A 100 ka 600 V 3RU2146-4H A 100 ka 600 V 3RU2146-4J A 100 ka 600 V 3RU2146-4K A 100 ka 600 V 3RU2146-4L A 100 ka 600 V 3RU2146-4M A 100 ka 600 V Overload from to (A) max. CB Short Voltage Relay 3VA51 Circuit 3RU2146-4D A 65 ka 480 V 3RU2146-4E A 65 ka 480 V 3RU2146-4F A 65 ka 480 V 3RU2146-4H A 65 ka 480 V 3RU2146-4J A 65 ka 480 V 3RU2146-4K A 65 ka 480 V 3RU2146-4L A 65 ka 480 V 3RU2146-4M A 65 ka 480 V Overload from to (A) max. CB Short Voltage Short Voltage Relay 3VA52 Circuit Circuit 3RU2146-4D A 100 ka 480 V 35 ka 600 V 3RU2146-4E A 100 ka 480 V 35 ka 600 V 3RU2146-4F A 100 ka 480 V 35 ka 600 V 3RU2146-4H A 100 ka 480 V 35 ka 600 V 3RU2146-4J A 100 ka 480 V 35 ka 600 V 3RU2146-4K A 100 ka 480 V 35 ka 600 V 3RU2146-4L A 100 ka 480 V 35 ka 600 V 3RU2146-4M A 100 ka 480 V 35 ka 600 V Standard / High Capacity Short Circuit Rating for Contactor, Overload Relay combination, (type 2 co-ordination). Contactor Overload Max. Voltage for High Fault Standard Fault Relay Fuse High Fault Current Current Class J Current 3RT1044 3RU1146-4J 90 A 600 V 100 ka 10 ka 3RT1044 3RU1146-4K 125 A 600 V 100 ka 10 ka 3RT1045 3RU1146-4L 175 A 600 V 100 ka 10 ka 3RT1046 3RU1146-4M 200 A 600 V 100 ka 10 ka Page 4 of 8
5 Standard Short Circuit Ratings, 3RU2146 (type 2 co-ordination): Overload from to (A) max. Fuse max. CB Short Voltage Relay Class J 3VA51 Circuit 3RU2146-4D A 100 A 5 ka 600 V 3RU2146-4E A 125 A 5 ka 600 V 3RU2146-4F A 125 A 5 ka 600 V 3RU2146-4H A 125 A 5 ka 600 V 3RU2146-4J A 125 A 10 ka 600 V 3RU2146-4K A 125 A 10 ka 600 V 3RU2146-4L A 125 A 10 ka 600 V 3RU2146-4M A 125 A 10 ka 600 V High-Capacity Short Circuit Ratings, 3RU2146 (type 2 co-ordination): Overload from to (A) max. Fuse Short Voltage Relay Class J Circuit 3RU2146-4D A 100 ka 600 V 3RU2146-4E A 100 ka 600 V 3RU2146-4F A 100 ka 600 V 3RU2146-4H A 100 ka 600 V 3RU2146-4J A 100 ka 600 V 3RU2146-4K A 100 ka 600 V 3RU2146-4L A 100 ka 600 V 3RU2146-4M A 100 ka 600 V Overload from to (A) max. CB Short Voltage Relay 3VA51 Circuit 3RU2146-4D A 65 ka 480 V 3RU2146-4E A 65 ka 480 V 3RU2146-4F A 65 ka 480 V 3RU2146-4H A 65 ka 480 V 3RU2146-4J A 65 ka 480 V 3RU2146-4K A 65 ka 480 V 3RU2146-4L A 65 ka 480 V 3RU2146-4M A 65 ka 480 V Page 5 of 8
6 High-Capacity Short Circuit Ratings (type 1 co-ordination): Contactor + from to (A) Short Voltage Max. Circuit Breaker Overload relay Ciricuit ED63B FD63B 3RT2044+3RU2146-4D 18 25A 25kA 600V 50 A 100 A 3RT2044+3RU2146-4E 22 32A 25kA 600V 125 A 125 A 3RT2044+3RU2146-4F 28 40A 25kA 600V 125 A 150 A 3RT2044+3RU2146-4H 36 50A 25kA 600V 125 A 200 A 3RT2044+3RU2146-4J 45 63A 25kA 600V 125 A 200 A 3RT2044+3RU2146-4K 57 75A 25kA 600V 125 A 200 A 3RT2044+3RU2146-4L 70 90A 25kA 600V 125 A 200 A 3RT2044+3RU2146-4M A 25kA 600V 125 A 200 A Contactor + from to (A) Short Voltage Max. Circuit Breaker Overload relay Ciricuit ED63B FD63B 3RT2044+3RU2146-4D 18 25A 65kA 480V 50 A 100 A 3RT2044+3RU2146-4E 22 32A 65kA 480V 125 A 125 A 3RT2044+3RU2146-4F 28 40A 65kA 480V 125 A 150 A 3RT2044+3RU2146-4H 36 50A 65kA 480V 125 A 200 A 3RT2044+3RU2146-4J 45 63A 65kA 480V 125 A 200 A 3RT2044+3RU2146-4K 57 75A 65kA 480V 125 A 200 A 3RT2044+3RU2146-4L 70 90A 65kA 480V 125 A 200 A 3RT2044+3RU2146-4M A 65kA 480V 125 A 200 A Overload relay from to (A) Short Voltage Max. CB Ciricuit+ 3VA51+ 3RU2146-4D 18 25A 14/18kA 600V 100 A 3RU2146-4E 22 32A 14/18kA 600V 125 A 3RU2146-4F 28 40A 14/18kA 600V 125 A 3RU2146-4H 36 50A 14/18kA 600V 125 A 3RU2146-4J 45 63A 14/18kA 600V 125 A 3RU2146-4K 57 75A 14/18kA 600V 125 A 3RU2146-4L 70 90A 14/18kA 600V 125 A 3RU2146-4M A 14/18kA 600V 125 A Page 6 of 8
7 Overload relay From to (A) Short Voltage Max. Circuit Breaker Circuit+ 3VA61+ 3VA62+ 3RU2146-4D 18 25A 18/22/25kA 600V 100 A 100 A 3RU2146-4E 22 32A 18/22/25kA 600V 100 A 100 A 3RU2146-4F 28 40A 18/22/25kA 600V 150 A 100 A 3RU2146-4H 36 50A 18/22/25kA 600V 150 A 100 A 3RU2146-4J 45 63A 18/22/25kA 600V 150 A 250 A 3RU2146-4K 57 75A 18/22/25kA 600V 150 A 250 A 3RU2146-4L 70 90A 18/22/25kA 600V 150 A 250 A 3RU2146-4M A 18/22/25kA 600V 150 A 250 A Overload relay from to (A) Short Voltage Max. CB Ciricuit+ 3VA51+ 3RU2146-4D 18 25A 25/35/65kA A 3RU2146-4E 22 32A 25/35/65kA A 3RU2146-4F 28 40A 25/35/65kA A 3RU2146-4H 36 50A 25/35/65kA A 3RU2146-4J 45 63A 25/35/65kA A 3RU2146-4K 57 75A 25/35/65kA A 3RU2146-4L 70 90A 25/35/65kA A 3RU2146-4M A 25/35/65kA A Overload relay From to (A) Short Voltage Max. Circuit Breaker Circuit+ 3VA61+ 3VA62+ 3RU2146-4D 18 25A 35/65kA A 100 A 3RU2146-4E 22 32A 35/65kA A 100 A 3RU2146-4F 28 40A 35/65kA A 100 A 3RU2146-4H 36 50A 35/65kA A 100 A 3RU2146-4J 45 63A 35/65kA A 250 A 3RU2146-4K 57 75A 35/65kA A 250 A 3RU2146-4L 70 90A 35/65kA A 250 A 3RU2146-4M A 35/65kA A 250 A + Ratings with 3VA51 circuit breaker: SEAS: 65kA, 240V; 25kA, 480V; 14kA, 600V MEAS: 65kA, 240V; 35kA, 480V; 18kA, 600V HEAS: 65kA, 240V; 65kA, 480V; 18kA, 600V + Ratings with 3VA61 circuit breaker: MDAE: 65kA, 240V; 35kA, 480V; 18kA, 600V HDAE: 65kA, 240V, 65kA, 480V; 22kA, 600V CDAE: 65kA, 240V; 65kA, 480V; 25kA, 600V LDAE: 65kA, 240V; 65kA, 480V; 25kA, 600V Page 7 of 8
8 + Ratings with 3VA62 circuit breaker: MFAE: 65kA, 240V; 35kA, 480V; 18kA, 600V HFAE: 65kA, 240V; 65kA, 480V; 22kA, 600V CFAE: 65kA, 240V; 65kA, 480V; 25kA, 600V LFAE: 65kA, 240V; 65kA, 480V; 25kA, 600V The auxiliary contacts are rated: B600/R300, 24 V dc / 2 A, 1NO + 1NC changeover contacts Nomenclature Breakdown: 3RU1146-4D B 0 I II III IV I. Basic Type Size S3 3RU poles SIRIUS Classic 3RU poles SIRIUS Innovation II. Setting Ranges -4D - 18 to 25 A -4E - 22 to 32 A -4F - 28 to 40 A -4H - 36 to 50 A -4J - 45 to 63 A -4K - 57 to 75 A -4L - 70 to 90 A -4M - 80 to 100 A III. Type of Terminals B - screw terminals D - cage clamp terminals for the terminals of control circuits IV. Type of Installation 0 - Installed to the contactor 1 - Installed to the Module 3RU1946-3AA01 or 3RU2946-3AA01 (Single Unit) Page 8 of 8
C E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED-CASE AND CIRCUIT BREAKER ENCLOSURES
More informationE44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices Type No 3RB2 followed by 0 or 1 followed
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,
More informationC E R T I F I C A T E O F C O M P L I A N C E
1512 E47705 Report Reference E4770519970821 15OCTOBER12 Issued to: SIEMENS AG DF CP R&D V 3 WERNERVONSIEMENSSTRASSE 48 9 AMBERG GERMANY This is to certify that representative samples of MOTOR CONTROLLERS,
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG DF CP R&D V 3 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Mechanically Operated and Solid-state
More informationCertificate of Compliance
Certificate of Compliance (012730_C_000) Issued to: Siemens AG DF CP R&D VC 2 WernervonSiemensStrasse 48 Amberg, 92224 GERMANY The products listed below are eligible to bear the CSA Mark shown Issued by:
More informationFile E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany
File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above
More informationFile E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:
File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,
More informationFile E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany
File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been
More informationSIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.
SIRIUS Innovations. Technical information for ring terminals SIRIUS Answers for industry. Order data Assembly up to 7.5 kw (S00) fused assembly 2 Motor Starter (Fuses, Contactor, Overload Relay) Contactor
More information3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,
Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,
More informationOverload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview
SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.
More informationPrüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: -Daten: U",", / U = 690V / U *o = 6kV Hersteller:
SIEMENS Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: 2996 c DF CP R&D VC 2 / Drutschmann Amberg ras: 2016-08-02 Date: Product Description 2996 c Typprtibescheinigung
More informationSIRIUS 3RU2 Thermal Overload Relays
Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to
More informationIEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101
IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1588199 (LR 12730-233) Master Contract: 165071 Project: 1588199 Date Issued: 2004/11/03 Issued to: Siemens AG A&D CD CC TS2 Werner-von-Siemens-Strasse 48 Amberg,
More informationType Approval Certificate
Type Approval Certificate This is to certify that the undernoted product(s) has/have been tested with satisfactory results in accordance with the relevant requirements of the Lloyd s Register Type Approval
More informationProtection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.
Protection Equipment Overload Relays Reference Manual 04/2011 Industrial Controls Answers for industry. Protection Equipment 2 3 7 7 8 9 14 1 16 17 18 18 19 20 2 26 27 28 29 30 32 37 38 40 42 Introduction
More informationThermal overload relay TF65 and TF96
Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and
More informationProtection Equipment
Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1271882 Master Contract: 165071 Project: 2429855 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention: Mr. Michael
More informationSiemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J
Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N
More informationThermal overload relay TF140DU and TF140DU-V1000
Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against
More informationGeneral technical data. Ambient conditions
Data sheet Overload relay 9...12 A For motor protection Size S00, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset!!! Phased-out product!!!
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More information27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10
27Overload Relays Overview Combinations of overload relays and contactors SIRIUS 3R 27Overload Relays Contactors Current range A 3RT10 1 Size S00 3/4/5.5 kw 3RT10 2 Size S0 5.5/7.5/11 kw 3RT10 3 Size S2
More information2.1. NEMA Contactors and Starters
3A Overload C306DN3B Contents Contactors Non-Reversing and Reversing...... Starters Three-Phase Non-Reversing and Reversing, Full Voltage.................... Starters Single-Phase Non-Reversing, Full Voltage,
More informationIndustry Automation Control Components
Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements
More informationProtection Equipment. 5/2 Introduction
Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1
More information1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.
SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary
More informationCerti cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic
Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers
More informationThermal Overload Relays
Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They
More informations A Confirmation Bestätigung
s A0215.02 Confirmation Bestätigung Product identification: Produktbezeichnung Manufacturer: Hersteller Address: Anschrift Fuseless Load Feeders Sicherungslose Verbraucherabzweige 3RV2.4.. + 3RT204.. +
More informationElectronic overload relays EF205 and EF370
Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More informationIndustrial Controls. Load Feeder. Configuring SIRIUS Innovations Selection data for Fuseless and Fused Load Feeders. Configuration Manual 04/2011
Load Feeder Selection data for Fuseless and Fused Load Feeders Configuration Manual 04/2011 Industrial Controls Answers for industry. Introduction 1 General information 2 Industrial switchgear Load feeders
More informationIndustrial Protection Products Edition
Industrial Protection Products 2016 Edition COMPANY PROFILE Shanghai Liangxin Electrical Co., LTD. one of the leading low-voltage electrical component manufacture in the high-end market, was established
More informationSelf-protected Combination Starters System PKZ 2-SP
Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationMotor Starter Protectors
Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker
More informationMotor Starter Protectors
Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker
More informationCertificate of Compliance
Certificate of Compliance Certificate: 2049843 (LR 12730-263) Master Contract: 165071 Project: 2460955 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention:
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationSicherungslose Verbraucherabzweige Leistungsschalter 3VA. fuseless load feeder circuit breaker
Nummer: Number: 3343 Bestätigung Confirmation Sicherungsloser Motorabzweig Zuordnungsart 1 2 nach IEC 60947-4-1 bei AC 400 V Fuseless Load Feeder Coordination type 1 2 according IEC 60947-4-1 at AC 400
More informationGeneral data 5/37. Overview
General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available
More informationNR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA
R Relays C US LISTED EU Germany Ukrain Russia South Africa USA NR Thermal Overload Relay. General. Certificates: CE, VDE, Ukrain, PCT, RCC, UL;. Electric ratings: AC 50/0Hz, 90V, 0.A~30A;.3 Tripping class:
More informationTechnical Information
-100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42
More informationItem Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0
Controlgear Products +27 () 11 97 116 sales@controlgear.co.za Siemens stock items on hand as at Mon, 3/4/218, 14:4 GMT+2 3NA3824-6 LV HRC FUSE LINK S 8A 69AC 25DC 3 3NA3832 LV HRC FUSE LINK GL/GG S 125A
More information3TM Vacuum Contactors
Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents
More informationFile E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL
File E14900 Project 98NK40464 January 11, 1999 REPORT on MOTOR CONTROLLERS MAGNETIC Siemens Energy & Automation Inc. Batavia, IL Copyright 1999 Underwriters Laboratories Inc. Underwriters Laboratories
More informationA302DN.40/.63A Thermal Current Motor Starter
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;
More informationElectronic overload relay EF65, EF96 and EF146
Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationTechnical specifications
Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith
More informationIEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors
04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,
More informationUL/CSA Non-fused Disconnect Switches
Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationThermal Overload Relays - WEG RW Series, 2 Pole
International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More informationFor Operation in the Control Cabinet 3RW Soft Starters
General Data Overview The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationSIRIUS 3RV2 motor starter protectors. Electrical Components for the Railway Industry
Electrical Components for the Railway Industry www.siemens.com/railway-components Introduction Motor Protection Page 2 2014-10-27 Description Motor Protection Description Spring-loaded and screw-type connection
More informationKT4 Manual Motor Starter
KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one
More informationIndustrial Controls. Load Feeders. Configuring the SIRIUS Modular System Selection data for Fuseless and Fused Load Feeders. Configuration Manual
Configuration Manual ndustrial Controls Load Feeders Configuring the SRUS Modular System Selection data for Fuseless and Fused Load Feeders Edition 09/2017 siemens.com ntroduction 1 General information
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More information4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control
. 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationSoftstarters Softstarters
, PSS & PST(B), PSS & PST(B) Low Voltage Products & Systems 6.1 General information PSR PSS From the moment the first electrical motors appeared, engineers have been searching for a way to avoid electrical
More informationDATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer
DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up
More information3RW Soft Starters. General data. 6/2 Siemens LV 1 N SIRIUS Soft Starters 01/2008. Siemens AG 2008
Siemens AG 2008 General data The advantages of the SIRIUS soft starters at a glance: Soft starting and smooth ramp-down 1) Stepless starting Reduction of current peaks Avoidance of mains voltage fluctuations
More informationSubmittal Data Information
Effective: NOVEMBER 3, 2014 JOB CONTRACTOR ITEM NO. Submittal Data Information TDX - Taco Duplex Starter ENGINEER REP. 301-2693 Supersedes: NEW TDX - TACO DUPLEX STARTER 1Ø, 230V, 1/10-15HP 3Ø, 200-460V,
More informationWELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A
WELCOME TO THE WORLD OF COMPLETE AUTOMATION Innovative MCS Starter Solutions MCS Starters and the New Mounting System 141A Welcome to the Wide World of Allen-Bradley Starters Innovative solutions for state
More informationProtectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.
Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,
More informationControls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)
Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More information3VU13, 3VU16 Circuit-Breakers
3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used
More informationBulletin 193-T1 Bimetallic Overload Relays
Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationI r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.
DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB
More informationMAGNETIC MOTOR STARTERS
Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors
More informationElectrical Components for the Railway Industry. SIRIUS 3RV2 motor starter protectors
Electrical Components for the Railway Industry SIRIUS 3RV2 motor starter protectors www.siemens.com/railway-components Introduction Motor Protection Page 2 Description Motor Protection Description Spring-loaded
More informationIdeal for use as a manual starter
Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT
More information3NP1 Fuse Switch Disconnectors up to 630 A
Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors
More informationControl Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD
Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control
More informationControls and Instruments
CHAPTER 9 Controls and Instruments A complex set of controls and instruments monitors the operation of an electric generator set. Equipment operators must understand what these controls and instruments
More informationComponents for EEx e Panels
Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37
More informationEPS-ECONOMY PUMP STARTER
EPS-ECONOMY PUMP STARTER NEMA 1 & 3R ENCLOSURES franklinwater.com EPS-ECONOMY PUMP STARTER - 1 & 3 PHASE, 50/60HZ, 200-600 VAC, 1-80A The enhanced Franklin Electric Economy Pump Starter (EPS) provides
More information1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control
. Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic
More informationABB s new control and protection devices
ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationFor Operation in the Control Cabinet
As an option the thyristors can also be protected by SITOR semiconductor fuses from short-circuiting so that the soft starter is still functional after a short-circuit (type of coordination ). Three LEDs
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More information