3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Size: px
Start display at page:

Download "3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,"

Transcription

1 Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER, SIZE S00, Technical Data CIRCUIT-BREAKER, SIZE S00, FOR MOTOR PROTECTION, CLASS 0, A REL A, N REL.4.2A SCREW CONNECTION, STANDARD BREAKING CAPACITY W. TRANSV. AUX. SWITCH NO/NC General technical data: Size of the circuit-breaker S00 Trip class CLASS 0 Protection class IP IP20 Ambient temperature / during the operating phase -20 C 70 C Item designation according to DIN 4079 extendable after IEC / according to IEC 750 according to DIN EN Design of the auxiliary switch Type of the driving mechanism / Motor drive design of the operating mechanism Product function Overload protection Short-circuit to earth recognition Phase disturbance recognition Product component auxiliary switch Undervoltage release mechanism trip indicator product extension / optional / Motor drive Main circuit: Type of voltage Number of poles Service power / at AC- at 400 V / rated value Service power / for three-phase servomotors rated value Arrangement of electrical connectors for main current circuit Adjustable response current of the non-delayed short-circuit release of the current-dependent overload release Q Q transverse rocker AC/DC 0.09 kw 0.09 kw front side 4.2 A 4.2 A 0.22 A 0.2 A

2 Continuous current / rated value Auxiliary circuit: number of NC contacts / for auxiliary contact number of NO contacts / for auxiliary contact number of change-over switches / for auxiliary contact 0 Short-circuit: Switch-off capacity limit short-circuit current at 400 V / rated value Design of the overcurrent release and short-circuit release Installation/mounting/dimensions: Type of fixing/fixation Width Height Depth Connections: Design of the electrical connection for main current circuit Further information: Information- and Downloadcenter (Catalogs, Brochures, ) Global Industry Mall (Online ordering system) A 00 ka thermomagnetic screw and snap-on mounting onto 5 mm standard mounting rail according to DIN EN mm 90 mm 8 mm Service&Support (Manuals, Certificates, Characteristics, FAQs,...) screw-type terminals last change: 04/06/2009 Siemens AG Corporate Information - Privacy Policy - Termsof Use

3 RV Motor Starter Protectors For Motor Protection RV0 Class 0 up to 2A SIRIUS Description The RV0 MSP s, can be used as components in Group Installation per NEC 40-5(C) to turn motors on and off. Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the RV0 is used as a component in Group Installation, multiple MSP s can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to provide a remotely operated starter. Ordering Information ON/OFF rocker mechanism with lockout. Adjustment dial for setting to motor FLA. Class 0 overload trip characteristics. Short circuit trip at 2 times the maximum setting of the FLA adjustment dial. Short circuit current rating: Ambient compensated up to 40 F (applies to side by side mounting). Phase loss sensitivity. Test trip function. Cage Clamp version. Auxiliaries and Accessories see pages /8 /5. General Information see pages /28 /. Technical Data see pages /20 /27. Dimensions see page /2. te: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only. UL short- Screw connection Cage clamp Instanta- circuit connection neous breaking Single- short circuit capacity FLA Phase 480 V List List Adjustment HP Ratings Three-Phase HP Ratings I > I cu Price Price Illustration Range 5V 20V 200V 20V 460V 575V A ka Catalog $ Catalog $ RV0 Frame Size S RV0-0AA0 6. RV0-0AA RV0-0BA0 6. RV0-0BA RV0-0CA0 6. RV0-0CA RV0-0DA0 6. RV0-0DA RV0-0EA0 6. RV0-0EA RV0-0FA0 0. RV0-0FA RV0-0GA0 0. RV0-0GA RV0-0HA0 0. RV0-0HA RV0-0JA0 0. RV0-0JA RV0-0KA0 0. RV0-0KA RV0-AA0 0. RV0-AA RV0-BA0 0. RV0-BA RV0-CA0 0. RV0-CA RV0-DA0 0. RV0-DA RV0-EA0 0. RV0-EA RV0-FA0 0. RV0-FA RV0-GA0 0. RV0-GA RV0-HA0 0. RV0-HA RV0-JA0 0. RV0-JA RV0-KA0 59. RV0-KA Accessories Transverse auxiliary switch NO + NC separately Approx. weight.02 kg RV9 0-E 24. RV9 0-2E 26. Select MSP by motor full load amps. Horse power ratings for reference only. Size S00 MSP are listed for group installation only. For additional auxiliary switches refer to Accessories, Page /8 (screw connection) and Page /5 (Cage Clamp connection). All setting ranges are suitable for use in group installation for the following ratings. Maximum short-circuit rating: S V, phase, 65,000 rms symmetrical amps; 600 V, phase, 0,000 rms symmetrical amps. The RT0 devices except suffix -J and -K are suitable for tap conductor protection in group applications used on the above levels. /4 Discount Code: SIRIUS Contactors, OL s, MSP s Siemens Energy & Automation, Inc.

4 IEC Controls Motor Starter Protectors SIRIUS RV motor starter protectors up to 00 A Size S Size S2 Size S00 Size S0 For motor protection CLASS 0 Selection and ordering data For motor protection CLASS 20 Selection and ordering data General data for SIRIUS motor starter protectors Size Rated current Page Size Rated current Page Page S00 up to 2 A /4 S2 up to 50 A /6 Technical data /20 S0 up to 25 A /5 S up to 00 A /6 Overview /28 S2 up to 50 A /5 Characteristics / S up to 00 A /5 Circuit diagrams / Dimension drawings /2 Ciruit Breaker RV7 SIRIUS RV9 Cage Clamp infeed system RV MSP auxiliaries and accessories Page Page Page Selection and ordering data /7 Selection and ordering data /8-9 Selection and ordering data /8 Circuit diagrams /7 Technical data /6 Technical data /26 Dimension drawings /7 Overview /6 Overview / Dimension drawings /47 Circuit diagrams /5 Dimension drawings /6 /2 Siemens Energy & Automation, Inc.

5 RV Motor Starter Protectors General Data RV up to 00 A (Domestic applications) SIRIUS Technical data Permissible ratings of devices approved for rth America, u s Motor Starter Protectors of the SIRIUS RV series are approved for u/s. According to UL 508 and C they can also be used with a load feeder contactor. These Motor Starter Protectors can be used as "Manual Motor Starter" for "Group Fusing", or for "Group Installation" or as "Combination Motor Controller Type E". Additional information is found on /29. RV as "Manual Motor Starter" If used as "Manual Motor Starter", the MSP is always operated in combination with a short-circuit protection device (upstream short-circuit protection device). As short-circuit protection device any fusible link ("group fusing") or circuit-breaker ("group installation") of a type and size compliant with American Basic Standard NFPA 70, Article 40-5 (c) can be selected for sufficient protection of the power supply cables. Approvals are found under the following file numbers containing the data listed: u Number File. E5694, Product Class NLRV s File. LR270, Product Class MSP hp rating Rated current up to AC 240 V up to AC 480 Y/277 V up to AC 600 Y/47 V for FLA max. I n I cu ) I cu ) I cu ) Type V singlephase A ka ka -phase ka RV / / Size S / FLA max. 2 A, 600 V 575/ RV Size S / / FLA max. 25 A, 600 V / RV Size S / FLA max. 50 A, 600 V / RV0 4/RV Size S / FLA max. 99 A, 600 V (99) hp rating = Power rating in horse power (maximum motor rating) FLA = Full Load Amps / Motor full load current ) Complies with "short circuit breaking capacity" to UL. /20 Siemens Energy & Automation, Inc.

6 RV Motor Starter Protectors General Data RV up to 00 A SIRIUS Overview S00 MSP with laterally mounted undervoltage release with leading auxiliary switch RV0 Motor Starter Protectors (MSP s) are built for a world of applications while meeting the requirements of control users worldwide. Each MSP features a manual ON/OFF switch, a Class 0 adjustable bimetallic overload relay (Class 20 available in the two largest frame sizes), and magnetic trip elements for short circuit protection. Construction The motor starter protectors are available in four sizes: Size S00 - RV0 Maximum rated current is 2 Amps. Suitable for motors up to 0 hp at 600V. Available in both screw terminal and Cage Clamp versions. Size S0 - RV02 Maximum rated current is 25 Amps. Suitable for motors up to 20 hp at 600V. Size S2 - RV0 Maximum rated current is 50 Amps. Suitable for motors up to 50 hp at 600V. Size S - RV04 Maximum rated current is 00 Amps. Suitable for motors up to 00 hp at 600V. Functions Releases RV motor starter protectors are equipped with bimetallicbased, inverse-time delayed overload releases - electromagnetic short-circuit releases. The overload releases can be set in accordance with the load current. The overcurrent releases are permanently set to a value times the rated current and thus enable trouble-free start-up of motors. The scale cover can be sealed to prevent unauthorized adjustments to the set current. Release classes The release classes of thermally delayed releases are based on the tripping time (t A ) at 7.2 times the operational current in cold state (excerpt from IEC ): CLASS 0 A 2 s < t A w 0 s CLASS 0 4 s < t A w 0 s CLASS 20 6 s < t A w 20 s CLASS 0 9 s < t A w 0 s The release must trip within this time! Operating mechanisms S00 MSP are actuated via a rocker operating mechanism and S0, S2 and S MSP s via a rotary operating mechanism. If the MSP trips, the rotary operating mechanism switches to the tripped position to indicate this. Before the MSP is reclosed, the rotary operating mechanism must be reset manually to 0 position, in order to prevent the former from closing by mistake before the fault has been cleared. In the case of MSP s with rotary operating mechanisms, an electrical signal can be output via a signalling switch to indicate that the MSP has tripped. All operating mechanisms can be locked in 0 position with a padlock (shackle diameter.5 to 4.5 mm). Application Operating conditions RV MSP s are suitable for use in any climate. They are designed for operation in closed rooms under normal conditions (e.g. no dust, corrosive vapours or harmful gases). Suitable enclosures must be provided for installation in dusty or damp rooms. Motor Protection RV MSP s use bimetallic heater elements to provide class 0 or 20 overcurrent protection for both AC and DC motors. The bimetallic heaters sense the motor current directly, so the overloads are insensitive to high frequencies, harmonic waves and sinusoidal currents and voltages. Each MSP has a fourth bimetallic strip that reacts only to the ambient temperature inside the control panel. This ambient compensation prevents the MSP from nuisance tripping when the panel temperature is higher than the ambient temperature of the motor. A built-in differential trip bar causes the MSP to trip faster on a phase loss condition, to help reduce motor damage from phase loss. Magnetic trip elements in each MSP take the device off line when it senses currents of 2 times the maximum FLA dial setting. RV 0-0 A A 0 SIRIUS MSP or Application Frame Size Standard Amperage Range Class Terminal Type Auxiliary Circuit Breaker 0 = Motor Protection = S00 Possible choices listed below see A = 0 = Screw Switch 7 = UL = S0 page /4-/7 for an entire listing B = 20 2 = Spring Loaded = S2 4 = S 0,, 4 B through K te: MPS s and Contactors of the same frame size are made to easily fit together with the use of a link module. /28 Siemens Energy & Automation, Inc.

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

Protective Devices: Circuit-Breakers 1 )

Protective Devices: Circuit-Breakers 1 ) Protective Devices: Circuit-Breakers 1 ) /2 Introduction SIRIUS circuit-breakers 1 ) up to 100 A / General data /20 For motor protection /22 For motor protection with overload relay function /23 For starter

More information

General data 5/37. Overview

General data 5/37. Overview General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available

More information

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20

More information

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry. SIRIUS Innovations. Technical information for ring terminals SIRIUS Answers for industry. Order data Assembly up to 7.5 kw (S00) fused assembly 2 Motor Starter (Fuses, Contactor, Overload Relay) Contactor

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Industry Automation Control Components

Industry Automation Control Components Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Short-Circuit Current Ratings

Short-Circuit Current Ratings UL 508 Type E Combination Motor Controller, TeSys GV Combination Meeting UL 508 Type E, UL File E164871 Table 2: TeSys GV2P Horsepower and SCCR Ratings In combination with line spacer GV2GH7 (stand-alone

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E 1512 E47705 Report Reference E4770519970821 15OCTOBER12 Issued to: SIEMENS AG DF CP R&D V 3 WERNERVONSIEMENSSTRASSE 48 9 AMBERG GERMANY This is to certify that representative samples of MOTOR CONTROLLERS,

More information

3RV2011-1AA10 CIRCUIT-BREAKER SCREW CONNECTION 1.6A

3RV2011-1AA10 CIRCUIT-BREAKER SCREW CONNECTION 1.6A Automation Technology > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS 3RV2 up to 40 A 3RV2011-1AA10 CIRCUIT-BREAKER SCREW CONNECTION

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V 804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor

CONTACTOR, AC KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION. General details: Main circuit: Product brand name. Size of the contactor Product data sheet CONTACTOR, AC-3 7.5 KW/400 V, DC 24 V, 3-POLE, SIZE S0, SCREW CONNECTION General details: Product brand name Product designation Size of the contactor Protection class IP / frontal/front

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

SIRIUS 3RV2 motor starter protectors. Electrical Components for the Railway Industry

SIRIUS 3RV2 motor starter protectors. Electrical Components for the Railway Industry Electrical Components for the Railway Industry www.siemens.com/railway-components Introduction Motor Protection Page 2 2014-10-27 Description Motor Protection Description Spring-loaded and screw-type connection

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name Product data sheet CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION General technical data: product brand name Size of contactor Protection class IP / on the front SIRIUS S00

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

Electrical Components for the Railway Industry. SIRIUS 3RV2 motor starter protectors

Electrical Components for the Railway Industry. SIRIUS 3RV2 motor starter protectors Electrical Components for the Railway Industry SIRIUS 3RV2 motor starter protectors www.siemens.com/railway-components Introduction Motor Protection Page 2 Description Motor Protection Description Spring-loaded

More information

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name Data sheet CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor S0 Product

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name Data sheet CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name Data sheet CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name Product data sheet CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION General technical data: product brand name Size of contactor Protection class IP / on the front

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Auxiliary Devices USL, CNL - Type No. 3RU1146 or 3RU2146 followed

More information

Self-protected Combination Starters System PKZ 2-SP

Self-protected Combination Starters System PKZ 2-SP Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name Data sheet CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL product brand name Product designation SIRIUS 3RT2 contactor General technical data: Size of contactor

More information

KT4 Manual Motor Starters

KT4 Manual Motor Starters s General Description...F99 Quick Selection Guide...F100 Accessories...F101 Contact Blocks...F101 Adapter Plates...F101 Release Modules...F102 Connecting Modules...F102 Mounting...F103 Enclosures...F103

More information

General technical data. Ambient conditions

General technical data. Ambient conditions Data sheet Overload relay 9...12 A For motor protection Size S00, Class 10 Contactor mounting Main circuit: screw terminal Auxiliary circuit: screw terminal Manual-Automatic-Reset!!! Phased-out product!!!

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays US Catalog January 2017 Motor protection and control Manual motor starters, contactors and overload relays Motor rated operational powers and currents The currents given below concern standard three-phase

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry. Protection Equipment Overload Relays Reference Manual 04/2011 Industrial Controls Answers for industry. Protection Equipment 2 3 7 7 8 9 14 1 16 17 18 18 19 20 2 26 27 28 29 30 32 37 38 40 42 Introduction

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

3RT2028-1BB40. at rectangular impulse at DC 10g / 5 ms, 7,5g / 10 ms at sine pulse at DC 15g / 5 ms, 10g / 10 ms

3RT2028-1BB40. at rectangular impulse at DC 10g / 5 ms, 7,5g / 10 ms at sine pulse at DC 15g / 5 ms, 10g / 10 ms Automation Technology > Industrial Controls > Switching Devices > Contactors and Contactor Assemblies > Power Contactors for Switching Motors > SIRIUS 3RT20 Contactors, 3-pole, up to 18.5 kw / 25 hp 3RT2028-1BB40

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D VC 2 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional

More information

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

3. Coils shall be of molded construction

3. Coils shall be of molded construction .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

Motor Protection. Presented By. Scott Peele PE

Motor Protection. Presented By. Scott Peele PE Motor Protection Presented By Scott Peele PE Motor Protection Overload on the motor load Fuses Heater Magnetic relay Short Circuit on motor circuit Fuses Breakers Single Phasing Overload Protection NEC

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information