1 Ref No: Date: February 8, 1995 INDUSTRIAL CONTROL EQUIPMENT NO. 2 To: Manufacturers of Industrial Control Equipment Subject: Publication of Technical Information Letter (T.I.L.) No D-21 on Interim Certification Requirements for Control Devices Rated at More Than 1500 V But Not More Than 7200 V for Electric Motors Background and Rationale The Scope of CSA Standard C22.2 No was limited to 5000 V ac, however when the Standard was revised in order to harmonize it with Standard UL 508, Industrial Control Equipment, the Scope was limited to 1500 V ac. In response to the needs of the industry, CSA has developed requirements for high voltage motor controllers based on the 1973 edition of CSA Standard C22.2 No 14 and UL Standard UL 347, High Voltage Industrial Control Equipment. The requirements are covered in the attached T.I.L. No D-21. The Scope of this T.I.L. represents an increase in the maximum voltage rating to 7200 V from 5000 V. Direction Applications should include the full company name, address, the location of each factory and a reference CSA file number(s), as applicable. When an application is received, customers will be advised of the quantity and type of sample required for evaluation. Applications and Inquiries If you wish to make an application, please contact one of the CSA Offices or CSA Network Partners listed below. TILDL1/DL027/1/dw Page 1 of 8
2 CSA Offices Telephone Telefax Moncton (506) (506) Montreal (514) (514) Rexdale (416) (416) Rexdale (Standards Sales) (416) (416) Winnipeg (204) (204) Edmonton (403) (403) Vancouver (604) (604) Hong Kong (852) (852) Japan (81) (81) CSA Network Partners Pacific Rim (and Far East): SAQAS (Australia) (61) (61) CCIC (China) (86) (86) HKSTC (Hong Kong) (852) (852) BIS (India) (91) (91) JQA (Japan) (81) (81) A-PEX (Japan) (81) (81) I-TEC (Japan) (81) (81) SIRIM (Malaysia) (60) (60) SANZ (New Zealand) (64) (64) SISIR (Singapore) (65) (65) KAIT (South Korea) (82) (82) CTS (Taiwan) (886) (886) Europe (and Middle East): OVE (Austria) (43) (43) LCIE (France) (33) (33) UTE (France) (33) (33) N.V. KEMA (Netherlands) (31) (31) VDE-PZI (Germany) (49) (49) PCBC (Poland) (48) (48) SII (Israel) (972) (972) IMQ (Italy) (39) (39) SEMKO AB (Sweden) (46) (46) SEV (Switzerland) (41) (41) BSI (U.K.) (44) (44) BSI Testing (U.K.) (44) (44) North America: CCL (Utah) (801) (801) PSE (California) (714) (714) PSE (Florida) (813) (813) South America: BV Bureau Veritas (55) (55) TILDL1/DL027/2/dw Page 2 of 8
3 TECHNICAL INFORMATION LETTER NO D-21 Certification and Testing Division Product Group: Industrial Control Date: February 8, 1995 Issued By: Jim Walsh/Nino Mancini EQUIPMENT: ITEM: Industrial Control Equipment Interim Certification Requirements for Control Devices Rated at More Than 1500 V But Not More Than 7200 V, for Electric Motors STANDARD NOS: CAN/CSA C22.2 No 0-M91 - General Requirements - Canadian Electrical Code, Part II CAN/CSA C22.2 No 14-M91 - Industrial Control Equipment 1. Scope This Technical Information Letter (T.I.L.) contains construction and test requirements for control devices rated more than 1500 V but not more than 7200 V, for starting, stopping, regulating, controlling, or protecting electric motors, and intended to be installed and used in nonhazardous locations in accordance with the Rules of the Canadian Electric Code, Part I. 2. General Requirements 2.1 The requirements of this T.I.L. shall be used in conjunction with the requirements of CSA Standard C22.2 No 14-M91 when certifying the equipment. 2.2 The requirements of this T.I.L. shall take precedence over those of the relevant Part II Standard having similar intent. 3. Definitions Controller - means a device or a group of devices for governing in some predetermined manner the electric power delivered to the apparatus to which it is connected. Class E1 high-voltage controller - means a controller rated over 2,000 volts but not over 7200 volts and employing its contacts for both starting the motor and interrupting short circuits. TILDL1/DL027/3/dw Page 3 of 8
4 Class E2 high-voltage controller - means a controller rated over 2,000 volts but not over 7200 volts and employing its contacts for starting the motor and fuses for interrupting short circuits. 4. Construction - Enclosure Doors and Covers 4.1 In high-voltage equipment, barriers shall be provided if necessary to prevent access to any live high-voltage parts, including insulated conductors located in enclosures containing low voltage parts and wiring. Rationale: Insulating barriers are required to prevent accidental contact of live parts that may result in shock hazard. The requirements appear in Clause of the 1973 edition of CSA Standard C22.2 No Controllers of the draw-out type shall comply with the requirements of Clause 4.1 with the draw-out unit removed from the cubicle. Automatic shutters or the equivalent shall be provided to close up any openings intended to accommodate the draw-out high-voltage stab contacts. Rationale: Draw-out type controllers can be removed without the use of a tool. Therefore, no live parts that may result in an shock hazard should become accessible after the removal of the controllers. The requirements appear in Clause of the 1973 edition of CSA Standard C22.2 No Doors providing access to high-voltage compartments and high-voltage fuses if used, shall be mechanically interlocked with the isolating means to permit opening the door only when all high-voltage parts are disconnected from the highvoltage source by a spacing of two inches or by equivalent insulation. There shall be visible proof when the door is open to clearly show that such disconnection has been made. Doors of compartments containing high-voltage components auxiliary to the controller (but not including fuses), and for which mechanical interlocking of doors is impracticable shall be bolted closed and provided with a warning sign. Rationale: The unbolted door of an electrical compartment for high-voltage wiring can be easily opened, resulting in the exposure of live parts. This could cause an electric shock for a user. Therefore, means should be provided to disconnect all high-voltage parts when the door is opened. The requirements appear in Clause of the 1973 edition of CSA Standard C22.2 No 14. Note: The requirements for visible proof specified in Clause 4.3 will be considered to be fulfilled if a clearly visible target is provided and is directly connected without auxiliary mechanisms to the shutter covering any bare live stab contacts. 4.4 Mechanical or electrical interlocking shall be provided to ensure that the contactor high-voltage contacts are open before the disconnecting means is opened unless the disconnecting means is a load break switch. Interlocking (either electrical or mechanical) also shall be provided to ensure that the contactor high-voltage contacts are open before the disconnecting means is closed. TILDL1/DL027/4/dw Page 4 of 8
5 Rationale: Contactor high-voltage contacts may be damaged, if they are not open before the disconnecting means is closed. Mechanical or electrical interlocking will prevent the occurrence of this problem. The requirements appear in Clause of the 1973 edition of CSA Standard C22.2 No Spacings Unless as permitted in Clause 4.5.2, spacings through air or oil, and spacings over surfaces in air or oil shall be not less than the values shown in Table 1. Rationale: Spacings between live parts and non-current-carrying metal parts for voltages more than 1500 V but not more than 7200 V are quite different from those for electrical circuits operating at 1500 V or less. The values shown in Table 1 provide the minimum spacings that will prevent electrical failures and shock hazard For components that are rated at 1500 V or less, spacings shall be in accordance with CSA Standard C22.2 No 14-M91. Rationale: Minimum electrical spacings for voltages at 1500V or less should be less than those for more than 1500 V. The requirement covers components that operate at 1500 V or less The high-voltage circuit of a controller operating at the nominal voltage range from 5000 V to 7200 V shall be capable of withstanding the impulse withstand test of Clause Tests 5.1 General The general test requirements of CSA Std. C22.2 No. 14-M91 shall be applicable. In addition to the tests required by that Standard, the additional tests of the following clauses 5.2 to 5.6 inclusive shall be applicable. 5.2 Overload For air break ac contactors in E2 controllers, the contactor shall be capable of interrupting six times the current corresponding to its horsepower rating at rated voltage, 50 percent power factor maximum and rated frequency. The test cycle shall be 2 (CO) unit operations at two-minute intervals followed in 30 minutes by 2 further (CO) unit operations at two-minute intervals or a cycle of equivalent severity. The controller structure shall be grounded through a 3-ampere fuse. Immediately after the above total test cycle the contactor shall be capable of carrying rated continuous current without replacement or adjustment of any parts. Any indication of failure to interrupt, or contact welding during test, or blowing of the 3-ampere fuse to ground, shall be classified as a failure. TILDL1/DL027/5/dw Page 5 of 8
6 Note: The requirements appear in Clause of the 1973 edition of CSA Standard C22.2 No Endurance Contactors shall be tested without load for 10,000 operations at the rate specified by the manufacturer. There shall be no mechanical failure of the contactor during this test. Note: The requirements appear in Clause of the 1973 edition of CSA Standard C22.2 No Short Circuit A Class E high-voltage controller shall be capable of interrupting its rated short circuit current, including any dc components in the test circuits during the test cycles specified in Clause Remarks: (a) (b) For the test specified in Clause 5.4.1, the controller structure is to be grounded through a 3-ampere fuse. Class E2 controllers are to be tested with fuses of the highest current rating for which the controller is intended to be used For a Class E high-voltage controller, the test cycle for the short-circuit test specified in Clause shall consist of a specified number of unit operations at stated intervals. A unit operation shall consist of a closing followed immediately by an opening of the circuit without purposely delayed action as designated by the letters "CO", signifying closing-opening. The test cycle shall be as follows: (a) (b) For a Class E1 controller: three (CO) unit operations at two minute intervals; and For a Class E2 controller: three (CO) unit operations separated by the interval required to renew the fuses, inspect contacts and replace them, if necessary At the end of any of the test cycles specified in Clause a Class E high-voltage controller shall comply with the following requirements: (a) General. A controller shall perform without the emission of flame from its enclosure. Blowing of the 3-ampere fuse between the controller enclosure and ground shall be considered a failure. On Class E2 controllers, welding of contact tips under the specified test duty cycle shall not be considered a failure. Remarks: On Class E2 controllers, it is not necessary for the contact tips to remain closed during the interrupting cycle. (b) Mechanical. The controller, with the exception of the blowing of fuses, shall be in substantially the same mechanical condition as at the beginning of the test. TILDL1/DL027/6/dw Page 6 of 8
7 (c) Electrical. The controller shall be capable of withstanding rated voltage in the open position and of carrying rated current at rated voltage for a limited time but not necessarily without exceeding the rated temperature rise. Remarks: After a test cycle at or near its interrupting rating, it is not to be inferred that the controller can again meet its interrupting rating without minor repairs, such as replacement of contacts. Note: The requirements appear in Clause to of the 1973 edition of CSA Standard C22.2 No Impulse Withstand A previously untested control shall be used. The voltage shall be full-wave 1.2 x 50 µs impulses in accordance with ANSI/IEEE Standard 4, and having a crest value in accordance with Table 2. Three positive and three negative impulses shall be applied. The minimum interval between pulses shall be 1 s. The equipment shall withstand the voltage impulse without breakdown in accordance with Clause Dry-type core and coil assemblies, such as reduced-voltage-starting reactors and autotransformers and control-circuit transformers, may be disconnected for this test The sequence of tests shall be as follows: (a) (b) (c) Test 1 - With the controller bus installed, the isolating means closed, the high-voltage motor circuit fuses (in case of Class E2 controllers) and control circuit fuses in place, and the contact in the open position, the test voltage as shown in Table 2 shall be applied between each electric circuit and grounded metal parts, and between each principle electric circuit and all other principle circuits, except that the impulse test need not be applied across the open tip gap of the contactor. Test 2 - Test 1 shall be repeated except that the contactor shall be closed. Test 3 - With the isolating means open, the impulse voltage shown in Table 2 shall be applied in each phase individually between the contacts of the isolating means across the isolating gap. If the isolating means has provision for automatically grounding its load side when in the fully opened position, the test voltage shall be the value specified under Tests 1 and 2. Note: The requirements appear in Section 32 of UL Standard UL 347 "High Voltage Industrial Control Equipment". 5.6 Dielectric Withstand For high voltage components rated 1501 to 7200 V, the Dielectric Withstand Test shall be conducted as required in clause 6.8 of C22.2 No. 14-M91. The applied test voltage shall be 2 1/4 times the rated voltage plus 2000 volts. TILDL1/DL027/7/dw Page 7 of 8
8 Voltage Rating 1,501-2,500 TABLE 1 (See Clause 4.5.1) MINIMUM SPACINGS FOR LIVE PARTS Minimum Spacing - Inches Between Bare Live Parts of Opposite Polarity and Between Bare Live Parts and Grounded Metal Parts Other Than the Enclosure Through Air 1.00 Through Oil 0.75 Over Surface in Air 2.00 Over Surface in Oil 1.00 Between Bare Live Parts and the Walls of Metal Enclosures Including Fittings For Conduit or Armoured Cable Through Air or Oil 2.00 Over Surface In Air or Oil ,501-7, Note: A metal piece attached to the enclosure is considered to be a part of the enclosure if deformation of the enclosure is liable to reduce spacings between the metal piece and bare live parts. TABLE 2 (See Clause 5.5) IMPULSE WITHSTAND TEST - CREST VOLTAGES a Impulse Test Voltage, Crest Kilovolts Tests 1 and 2 Test 3 Level A a Level B Level A a Level B The Level A test voltages may be used if appropriate to the degree of exposure to lightning overvoltage, the type of system grounding, and the type and location of surge arrestor on the source side. TILDL1/DL027/8/dw Page 8 of 8
BATTERY CHARGERS NO. 3
Date: January 10, 1992 BATTERY CHARGERS NO. 3 To: Subject: Manufacturers of Commercial/Industrial Battery Chargers Expansion of CSA Certification Service for Power Supplies to Include Low Voltage, Outdoor
More informationInformation Technology and Economic Development: An Introduction to the Research Issues
November 1998 Working Papers No. 153 Information Technology and Economic Development: An Introduction to the Research Issues TABLE 1 WORLD-WIDE INFORMATION TECHNOLOGY MARKET BREAKDOWN, 1995
More informationPresented to the IAPMO Standards Review Committee on December 9, 2013
Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationFile E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:
File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,
More informationAn Urgent Bulletin from CSA Group
An Urgent Bulletin from CSA Group Elevator Equipment No. 24 Effective Date: January 1, 2019 Date: May 3, 2018 Apply Before September 1, 2018 Announcing: Withdrawing of TIL CSA D-11B and Publication of
More informationPrimary energy. 8 Consumption 9 Consumption by fuel. 67 th edition
Primary energy 8 Consumption 9 Consumption by fuel 67 th edition Primary energy Consumption* Growth rate per annum Million tonnes oil equivalent 27 28 29 2 211 212 213 214 215 216 217 217 26-16 Share 217
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationBP Statistical Review of World Energy June 2017
BP Statistical Review of World Energy June 217 Primary energy 8 Consumption 8 Consumption by fuel 9 66 th edition Primary energy Consumption* Growth rate per annum Million tonnes oil equivalent 26 27 28
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationTotal credit to the non-financial sector (core debt), % of GDP Table F1.1
Total credit to the non-financial sector (core debt), % of GDP Table F1.1 2012 2013 2014 2015 2016 Q2 16 Q3 16 Q4 16 Q1 17 Q2 17 Argentina 62.6 66.4 64.6 75.5 75.3 81.7 80.1 75.3 71.6 72.7 Australia 208.0
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationRef No: N Date: December 7, Fuseholder Assemblies No. 2. Call us today! See Attachment 1 for Effective Dates.
Ref No: N07-094 Date: December 7, 2007 Fuseholder Assemblies No. 2 See Attachment 1 for Effective Dates. Call us today! We can help you stay on top of changes that will affect your Certification! 1-866-797-4272
More informationG-Series DIN-RAIL CIRCUIT BREAKER
G-Series DIN-RAIL CIRCUIT BREAKER The G-Series hydraulic-magnetic circuit breaker insures maximum protection by integrating wiping contacts for longevity; a common trip linkage between poles; a unique
More informationCertificate of Compliance
Certificate of Compliance Certificate: 1588199 (LR 12730-233) Master Contract: 165071 Project: 1588199 Date Issued: 2004/11/03 Issued to: Siemens AG A&D CD CC TS2 Werner-von-Siemens-Strasse 48 Amberg,
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationFile E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany
File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above
More informationZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :
Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report
More informationWorld Air Conditioner Demand by Region
World Air Conditioner Demand by Region April 2015 The Japan Refrigeration and Air Conditioning Industry Association 1 World Air Conditioner Demand by Region April 2015 The Japan Refrigeration and Air Conditioning
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationMIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6
I. PART 1 GENERAL 1. SCOPE A. NEMA Premium copper-wound ultra low loss isolation transformer with a higher efficiency than that required by NEMA Std. TP-1. Optimized for energy efficiency over a wide load
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More information60T Series Snap-Action Temperature Controls
60T Series Snap-Action Temperature Controls Snap-Action Temperature Control The 60T line of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a versatile, cost-effective
More informationSWITCHGEAR DIVISION PRODUCT PROFILES
SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More information1204 Terminator. Instructions 1204 T F B2. (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used. What this Option Contains
Instructions 1204 Terminator (Catalog Number 1204-TFA1, 1204-TFB2) Where this Option is Used The 1204 Terminator Option can be installed in most adjustable frequency AC drive applications to increase protection
More informationPacking Data Installation Instructions
Packing Data PK Installation Instructions This document describes how to install a Dataliner DL10 display in a panel or enclosure and connect power. European Union Directive Compliance wiring and safety
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationJ-Series CIRCUIT BREAKER
J-Series CIRCUIT BREAKER Designed to provide high levels of circuit protection, the J-Series is a compact, low profile hydraulic magnetic circuit breaker ideally suited for high power density applications.
More information7BT2 SERIES 30 F to 400 F, High Capacity, ½
7BT2 SERIES 30 F to 400 F, High Capacity, ½ Introduction KLIXON 7BT series high current capacity thermostats provide customers with an enivronmentally sealed thermal switch capable of carrying up to 15
More informationSBS-Control. Table of contents. Operating Instructions BKS24-9A. Operating Instructions
Operating Instructions BKS24-9A Operating Instructions BKS24-9A Table of contents Operating Instructions 1 Operating controls and indicators 2 2 Preparations for faultless commissioning and operating 3
More informationDISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS
Prepared by: SXZO DISCONNECT SWITCH REQUIREENTS FOR DISTRIBUTED GENERATION CUSTOERS 060559 Department: Electric Distribution Section: Design and Construction Approved by: D.Jantz (DWJ7) Date: 8/15/17 Rev.
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More informationAR circuit breaker - Hydraulic magnetic,
AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against
More informationSECTION MOTORS AND VARIABLE FREQUENCY DRIVES
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Related Sections: 1. Section 15050 - Basic Mechanical Requirements. 2. Section 15051 - Motors. 3. Section 15185 - Hydronic Pumps. 4. Section 15625 - Centrifugal
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationCLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001
CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS
More informationISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO
P-EX01-A Solenoid Valve (with M Connector) Conforming to ISO 1507-1, Large capacity EVS1-01 (Size: 01) EVS1-0 (Size: 0) Light weight Size 01 (-position): 0.6kg Size 0 (-position): 0.18kg Flow rate 1000L/min
More information5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application
The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1
More informationRectangular photoelectric proximity switches
Rectangular photoelectric proximity switches Features Diffuse sensors with operating distance of 300 mm or 800 mm Through-beam sensors with operating distance of 15 or 50 m Reflex sensors with operating
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationLine Gard. Underwriters Laboratories (UL) Applicable Code Notation
Underwriters Laboratories (UL) UL 50E Enclosures for Electrical Equipment, Environmental Considerations 1.1 This standard applies to enclosures for electrical equipment intended to be installed and used
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements
More informationFork through-beam sensors
Fork throughbeam sensors Features Wide range of sizes: fork widths from 2 to 220 mm Metal housings Integrated evaluation unit Connection by means of S8 connector Degree of protection Adjustable sensitivity
More informationTECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT
Page 1 (7) TECHNICAL REQUIREMENTS FOR ELECTRICAL EQUIPMENT Title Document Asynchronous electric motors TBE 103 Issue 6 (E) Contents 1 GENERAL... 2 2 DEFINITIONS... 2 3 GENERAL PRODUCT REQUIREMENTS... 3
More informationType SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear
Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated
More informationCoal. 36 Reserves and prices 38 Production and consumption. 67 th edition
Coal 36 Reserves and prices 38 Production and consumption 67 th edition Total proved reserves at end 217 Million tonnes Anthracite and bituminous Subbituminous and lignite US 228 3116 25916 24.2% 357 Canada
More informationL-Series. Circuit Breaker
L-Series Circuit Breaker Carling Technologies is pleased to introduce the new L-Series Circuit Breaker, a compact, high performance breaker ideally suited for the rigors and confined spaces found in today
More informationFR circuit breaker - hydraulic magnetic,
FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary
More informationKeysight Technologies Benefits of Moving to 1,500 V Photovoltaic Inverters. Application Note
Keysight Technologies Benefits of Moving to 1,500 V Photovoltaic Inverters Application Note 02 Keysight Benefits of Moving to 1,500 V Photovoltaic Inverters - Application Note If you have been reading
More informationFEDERAL RESERVE statistical release
FEDERAL RESERVE statistical release FOR IMMEDIATE RELEASE MARCH 16, 1992 E.U C1Z1, GEOGRAPHICAL r DISTRIBUTION n OF e ASSETS AND^LIABILITIES (IN MILLIONS OF DOLLARS) ASSETS COUNTRY OF CUSTOMER 12/31/90
More informationEvaluating Battery Run-Down with the N6781A 2-Quadrant Source/Measure Unit and the 14585A Control and Analysis Software.
Evaluating Battery Run-Down with the N6781A 2-Quadrant Source/Measure Unit and the 14585A Control and Analysis Software Application Note Analyzing and optimizing battery run time requires running tests
More informationFork through-beam sensors
Fork throughbeam sensors Features Wide range of sizes: fork widths from 2 to 220 mm Metal housings Integrated evaluation unit Connection by means of S8 connector Degree of protection Adjustable sensitivity
More informationSERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES
SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD
More informationTRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES
TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG DF CP R&D V 3 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional
More informationEVOline Socket Modules
203 Protection types in sockets. Colour table Standard-colours To order other colours in RAL-Tones, please contact us. With contact protection Contact protection: Contact socket with child protection (increased
More informationFR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet
FR circuit breaker - hydraulic magnetic, railway, Datasheet very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary
More informationWELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2
WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 DESCRIPTION OF SERVICE A. General: RULE NO. 2 1. Alternating current service at 60-hertz (cycles per second)
More informationInfographics on Electromobility (January 2019)
Infographics on Electromobility (January 2019) Publisher: BMW Group Corporate Communications Electromobility Last Update: 04.01.2019 Contact: presse@bmw.de ELECTROMOBILITY IN GERMANY. SHARE IN NEW REGISTRATIONS
More informationUnderstanding BS 1363 Amendment No.4
Intertek Hilton House, Corporation Street, Rugby, Warwickshire, CV21 2DN UK info.uk@intertek.com 01788 578435 www.intertek.com Introduction A new Amendment applying to several parts of the BS 1363 standard
More informationINTERPLANT STANDARD - STEEL INDUSTRY
INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION FOR MAGNETIC OVER- CURRENT RELAYS FOR ac AND dc MOTORS PROTECTION UP TO 650 V (FIRST REVISION) CORRESPONDING INDIAN STANDARD DOES NOT EXIST IPSS:1-04-008-11
More informationThe Use of Electricity In Mines Regulations
The Use of Electricity In Mines Regulations Repealed by Chapter E-6.3 Reg 4 (effective February 28, 1996). Formerly Chapter E-7.1 Reg 5. Table of Contents 1 Title 2 CSA Standard adopted with amendment
More information2016 Photovoltaic Solar System Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE
More informationIntertek Level 4 RTL (ASTA Recognized Laboratory Scheme)
Page 1 of 6 Site(s) applicable to the recognition: Central Power Research Institute Prof Sir C.V. Raman Road P.B. No. 8066 Sadashivanagar Sub-P.O. Bangalore 560 080 India Central Power Research Institute
More informationA. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.
PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the
More informationSTOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:
SolarEdge Single Phase StorEdge TM Solutions for North America 12-25 STOREDGE TM SolarEdge StorEdge Solutions Benefits: More Energy - DC-coupled architecture stores PV power directly to the battery without
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationCircuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.
Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November
More informationSGS Australia Pty Ltd
TEST REPORT AS/NZS 60598.2.2:2001 Luminaires Part 2: Particular requirements Recessed luminaires Report Reference No....: S08007 Approved by (+ signature)...: I Absolom Date of issue...: Thursday, 31 January
More informationNet +Plus Connection Code
Net +Plus Connection Code LANKA ELECTRICITY COMPANY (PRIVATE) LIMITED 1.0 BACKGROUND The existing Net Metering Concept launched in the year 2010 noticed an exponential growth in the recent year and at
More information100 / 110 DRYWELL FUSE SPECIFICATION
100 / 110 DRYWELL FUSE SPECIFICATION 15KV & 25KV SUBMERSIBLE VACUUM LOAD INTERRUPTERS AND DRYWELL FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED SUBMERSIBLE SWITCHGEAR WITH LOAD INTERRUPTING SWITCHES
More informationSIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC
c c SIEMENS Series 8100oT Vacuum Controllers Bulletin CC3802-02 Technological Development Vacuum technology has developed rapidly in recent years and is becoming widely accepted for medium voltage motor
More informationTable B1. Advanced Economies: Unemployment, Employment, and Real per Capita GDP (Percent)
Statistical Appendix Table B1. Advanced Economies: Unemployment, Employment, and Real per Capita GDP (Percent) Unemployment Rate 2 Averages 1 1993 2002 2003 12 Advanced Economies 6.8 6.9 6.7 6.5 6.3 5.8
More informationSelecting DC Sources for Telecommunications Equipment Test Systems
Selecting DC Sources for Telecommunications Equipment Test Systems Application Note Overview When selecting DC sources for test systems for telecommunications equipment one must take industry standards
More informationMEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV
CE--C-en-REV.04 2016.1 MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE- Metal Clad switchboards family are designed for use in public and industrial distribution system up to 40,5kV for the operation and
More informationUView Mini Transilluminator
UView Mini Transilluminator Instruction Manual Catalog #166-0531 Hardware Instruction Manual The UView mini transilluminator is suitable for research use only. It must be used by specialized personnel
More informationPDR circuit breaker - Ground fault Datasheet
- Ground fault Datasheet protection device Features Blue housing 1-3 poles plus neutral 7-100mA Preciese, temperature independent operation Choise of time delays, terminals and actuator colours Application
More informationTechnical Specification For Outdoor Substation Harmonic Filter Banks
Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field
More informationElectropneumatic Timing Relays Series 7000 Industrial
DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated
More informationCircuit breaker interlocking and operation requirements SIEMENS
Circuit breaker interlocking and operation requirements SIEMENS When manufacturers and specifiers discuss circuit breaker operational and interlocking requirements, several terms are used repeatedly. Despite
More informationWLTP for fleet. How the new test procedure affects the fleet business
WLTP for fleet How the new test procedure affects the fleet business Editorial Ladies and Gentlemen, The automotive industry is facing a major transformation process that will also affect the fleet business
More informationPerformance Derby: MSCI Regions/Countries Earnings & Revenues Growth 2019E / 2018E / 2017A
Performance Derby: MSCI Regions/Countries Earnings & Revenues Growth 2019E / 2018E / 2017A February 28, 2018 Dr. Ed Yardeni 516-972-7683 eyardeni@yardeni.com Joe Abbott 732-497-5306 jabbott@yardeni.com
More informationThick Film Chip Resistors
Thick Film Chip Resistors Features: Small size and light weight. Suitable for both flow and reflow soldering. Reduction of assembly costs and matching with placement machines. Performance Specifications:
More informationGlobal Summary Report Market for High Voltage Switchgear
Global Summary Report Market for High Voltage Switchgear 2012-2022 GOULDEN REPORTS October 2016 No 1, Priorsfield, Marlborough,WiltshireSN8 4AQ, United Kingdom Tel: +44 1672 513316 Fax: +44 1672 513316
More informationMain switches in accordance with European standard directives
Main switches in accordance with European standard directives N N ABB y ABB Switches in accordance with EU Directives New concept n order to dismantle technical barriers in commerce, the Council of the
More information43-SDMS-04 REV. 00 SPECIFICATIONS FOR
43-SDMS-04 REV. 00 SPECIFICATIONS FOR SHUNT CAPACITOR BANK 13.8 kv THROUGH 69 kv FOR PRIMARY DISTRIBUTION SUBSTATIONS This specification is property of SEC and subject to change or modification without
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60470 Second edition 1999-10 High-voltage alternating current contactors and contactor-based motor-starters Contacteurs pour courants alternatifs haute tension et démarreurs
More information67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production
Renewable energy 44 Other renewables consumption 45 Biofuels production Appendices A1 Solar Generation A2 Wind Generation A3 Geothermal, biomass and other Generation A4 Geothermal Cumulative installed
More informationMODERNISATION SOLUTIONS. MRM W Line. TIME FOR A FACE-LIFT!
MODERNISATION SOLUTIONS TIME FOR A FACE-LIFT! ADVANCED FEATURES WITTUR SOLUTION FOR MODERNISATION The, Wittur flexible machine roomless electric lift, offers an ideal solution for new lifts in existing
More informationAn Urgent Bulletin from CSA Group
Ref No: I15-014 Elevator Equipment No. 20 (Supersedes Elevator Equipment Certification Notice No. 1A, and Informs Elevator Equipment No 1B) Date: January 21, 2015 An Urgent Bulletin from CSA Group Existing
More informationWORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018
QUARTERS 2017-2018 June 14, 2018 CONTENTS BASEPROTOTAL BASEPROCARS BASEPROLCV BASEPROHCV BASEPROBC Summation of cars, LCVs, HCVs, heavy buses Cars LCVs HCVs Heavy buses Note: The production of cars and
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationPATTERSON PUMP COMPANY
PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL
More information