Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Size: px
Start display at page:

Download "Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE"

Transcription

1 Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused Switches Operating Handle Ingress Ratings: - IP (Type ) - IP (Type R,,,, X) Handle with or without Test Mode Padlockable handle for up to three padlocks Up to Auxiliary Contacts can be added per switch Suitable as Service Entrance Disconnecting Means (UL) Suitable as At-Motor Disconnecting Means (UL0) Certifications UL Listed (File No. E, Guide NLRV; File No. E, Guide WHTY) CSA Certified (File No. LR) CE Standards Compliance IEC 0/EN0- BS EN0- VDE 00 CSA. No. NEMA KS- UL UL 0 The Bulletin R line of fused and non-fused global disconnect switches provides the flexibility to meet worldwide applications. These rodoperated disconnect switches incorporate removable fuse carriers that have high short circuit protection ratings. The disconnect switches are UL Listed and CSA Certified and are designed to meet IEC 0-, VDE, DIN, BS and applicable NEMA requirements. Product Selection Open Switches Cat. No. Explanation Table of Contents Product Selection Open Switches... this page NFPA Operating Shaft/Handle Kits... - Specifications... - Proper Selection of Disconnect Switches - Fuse Description... - Code C a Fuse Type Description R-J0- UL Class CC, CSA Type HRCI-MISC (0 A) UL Class J, CSA Type HRCI-J (0 A or J 0 A) H CSA Type HRCII-C (0 A or 0 A) B BS (0 A, A, or A) D DIN ( A or A) F NFC ( A, A, or A) N Non-fused (0 A or 0 A) R J 0 S a b c d b Load Size Code Description Dimensional Ref. 0 0 A (BS) A A (NFC) A 0 0 A (CC, J, HRCI-J) A 0 A (Non-Fused) A 0 A (HRCII-C) B A (BS, NFC) A A (DIN) B 0 0 A (J, HRCI-J, HRCII-C) B 0 0 A (Non-Fused) B A (BS, DIN, NFC) B See page -0 for dimensional reference data. Limit of total auxiliary contact blocks total for test and standard positions. * Fourth pole, additional auxiliary contacts and handle options available in accessory section. Non-fused disconnect switches must use separately installed fuses for upstream short-circuit protection No. of Poles Code Description -pole switch Fuse Indication Code Configuration Blank No fuse status indication S Fuse status indication c d -0

2 Bulletin R IEC Product Selection UL/CSA Fused Disconnect Switches Cat. No. R-J0- Non-Fused Disconnect Switches Maximum Hp Ratings Rated Ø (0 Hz) Ø (0 Hz) DC Dim. Current V 0V 0V 0V 00V V 0V Fuse Ref. Cat. No. UL Class CC and CSA HRCI-MISC Fuses A CC, HRCI-Misc A R-C0- UL Class J and CSA HRCI-J Fuses A Class J, HRCI-J A R-J A Class J, HRCI-J B R-J0- CSA HRCII-C Fuses A HRCII-C B R-H A HRCII-C B R-H0- Time delay fuses may be required to utilize the disconnect switch at its maximum horsepower rating. Fuse Description Non-fused disconnect switches must use separately installed fuses for upstream short circuit protection. R-N0- Rated Current Non-Fused Maximum Hp Ratings Ø (0 Hz) Ø (0 Hz) DC V 0V 0V 0V 00V V 0V Dim. Ref. Cat. No A R-N B R-N0-0 A UL-rated device has I the of 0 A per IEC. 0 A UL-rated device has I the of 0 A per IEC. -0

3 Bulletin R Product Selection, Continued IEC Fused Disconnect Switches R-F- R-F- BS Fused Disconnect Switches DIN Fused Disconnect Switches Ratings (AC) With Fuse Links Ø Maximum kw (0 Hz) Dim. Load Rating I e 00/0V 0/00/V 0/0V Fuse Ref. Cat. No.. 0 NH 000 B R-D-. 0 NH 000 B R-D- NFC Fused Disconnect Switches Ratings (AC) With Fuse Links Load Rating I Ø Maximum kw (0 Hz) e Dim. 00/0V 0/00/V 0/0V Fuse Ref. Cat. No. 0. BS A A R-B0-. 0 BS A A R-B-. 0 BS A B R-B- Ratings (AC) With Fuse Links Ø Maximum kw (0 Hz) Dim. Load Rating I e 00/0V 0/00/V 0/0V Fuse Ref. Cat. No.. NFC x mm A R-F-. 0 NFC x mm A R-F-. 0 NFC x mm B R-F- -0

4 Bulletin R IEC Product Selection, Continued Accessories th Pole Modules BS Fuses Maximum Hp Ratings Ø (0 Hz) Ø (0 Hz) DC Rated Dim. Current V 0V 0V 0V 00V V 0V Fuse Ref. Cat. No. Non-Fused 0. 0 A R-0-NN B R-0-NN UL Class CC and CSA HRCI-MISC Fuses A CC, HRCI-Misc A R-0-NC UL Class J and CSA HRCI-J Fuses A J, HRCI-J A R-0-NJ A J, HRCI-J B R-0-NJ CSA HRCII-C Fuses A HRCII-C B R-0-NH A HRCII-C B R-0-NH Time delay fuses may be required to utilize the disconnect at its maximum horsepower rating. 0 A UL, 0 A IEC 0 A UL, 0 A IEC Ratings (AC) With Fuse Links Ø Maximum kw (0 Hz) Dim. Load Rating I e 00/0V 0/00/V 0/0V Fuse Ref. Cat. No. 0. BS A A R-0-NB. 0 BS A A R--NB. 0 BS A B R--NB DIN Fuses Ratings (AC) With Fuse Links Ø Maximum kw (0 Hz) Dim. Load Rating I e 00/0V 0/00/V 0/0V Fuse Ref. Cat. No.. 0 NH 000 B R--ND. 0 NH 000 B R--ND NFC Fuses Ratings (AC) With Fuse Links Ø Maximum kw (0 Hz) Dim. Load Rating I e 00/0V 0/00/V 0/0V Fuse Ref. Cat. No.. NFC x mm A R--NF. 0 NFC x mm A R--NF. 0 NFC x mm B R--NF -

5 Bulletin R Product Selection, Continued Operating Handles (Accepts Padlocks) For Use With Description Color Degree of Protection Cat. No. A, A, B, B A, A, B, B Test mode handle with defeater Standard handle test mode with defeater Standard handle without defeater Black Red/Yellow Black Red/Yellow Black Red/Yellow (Type R,,,, X) IP (Type R,,,, X) IP (Type ) IP (Type R,,,, X) IP (Type ) IP (Type R,,,, X) IP (Type ) IP (Type R,,,, X) IP (Type ) IP (Type R,,,, X) IP R-HST R-HSTE R-HS R-HS R-HSE R-HSE R-HS-N R-HS-N R-HSE-N R-HSE-N OSHA Lockout/Tag Out Compliance (LOTO) OSHA CFR Section mandates that disconnects be able to be locked out while in the OFF position during servicing. All Bulletin R handles comply with this important safety requirement. (Please see NFPA Article 0 for disconnect requirements of motor applications) Operating Shafts Disconnect Switch Dim. Ref. A, A, B, B Operating Shaft Type Standard Length Extended Length Operating Shaft Length Approx. Dim. mm (in.) (.) (.0) Disconnect Switch Dim. Ref. Enclosure Working Depth Minimum Approx. Dim. mm (in.) Maximum Approx. Dim. mm (in.) A, B (.) 0 (.) A, B (.) 0 (.) A, B (.) (.) A, B (.) (.) Cat. No. R-R R-R -

6 Bulletin R IEC Accessories NFPA Operating Shaft/Handle Kits An internal handle that permits operation of the disconnect switch when the panel door is open, in compliance with NFPA. Description NFPA Handle Kit Includes NFPA handle, operating shaft, and Cat. No. R-PLA padlocking attachment Shaft Length [mm (in.)] Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. 0 () A, A, B, B R-NHR () A, A, B, B R-NHR Other Accessories Description Operating Shaft Guide Allows easier coupling of shaft to operating handle if misalignment occurs between switch and enclosure after assembly installation Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. A, A, B, B R-HSG Shaft Guard Provides extra protection against contact with shaft Operating Shaft Coupler Used with Cat. Nos. R-R and R-R shafts to extend shaft length an additional. in. Operating Handle Instruction Label Describes the function of the operating handle for opening the enclosure door with the disconnect switch in the ON and OFF position A, A, B, B R-RG A, A, B, B R-SC ALL R-L Replacement Mounting Hardware Pkg. Qty. Description For Use With Cat. No. set screw, shaft clip, and # M screws set screw, shaft clip, and # M screws A, A R-0-HDWR B, B R-0-HDWR Replacement Fuse Hardware Description For Use With Pkg. Qty. Cat. No. M x. Fuse screws R BS Fuse Types R-BS-M M x. Fuse screws R BS Fuse Types R-BS-M -

7 Terminal Shields Bulletin R Accessories, Continued Disconnect Quantity Required Per Description Switch Dim Ref. Disconnect Switch Pkg. Qty. Cat. No. 0 A Terminal Shield ( terminals) A, A R-0-C 0 A Terminal Shield ( terminal) B, B R-0-C 0 A Terminal Shield ( terminal) A, A R-0-C 0 A Terminal Shield ( terminal) B, B R-0-C For use on either Line or Load Side of Disconnect Switch. Disconnect Switch Padlock Accessory Disconnect Switch Dim Ref. Pkg. Qty. Cat. No. A, A, B, B R-PLA Replacement Fuse Carriers Description Pkg. Quantity Cat. No. 0 A CC Fuse Carrier R-C0-FC 0 A J Fuse Carrier R-J0-FC 0 A J Fuse Carrier R-J0-FC 0 A BS Fuse Carrier R-B0-FC A BS Fuse Carrier R-B-FC A BS Fuse Carrier R-B-FC 0 A CSA HRCII-C Fuse Carrier R-H0-FC R-J0-FC 0 A CSA HRCII-C Fuse Carrier R-H0-FC A DIN Fuse Carrier R-D-FC A DIN Fuse Carrier R-D-FC A NFC Fuse Carrier R-F-FC A NFC Fuse Carrier R-F-FC A NFC Fuse Carrier R-F-FC 0 A Non-Fuse Carrier R-N0-FC R-J0-FCS 0 A Non-Fuse Carrier R-N0-FC For fuse status indication add "S" to catalog number, example: R-J0-FC becomes R-J0-FCS Auxiliary Contact Blocks Description Contact Material Pkg. Quantity Cat. No. Contact Block Note: Sold only in multiples of. Order (quantity of) to receive one package of pieces. Latch not included. N.O. N.C. N.O.E.M. N.C.L.B. N.O. with stab terminals N.C. with stab terminals N.O. spring-clamp 00F-X 00F-X0 00F-XE 00F-X0L 00F-XT 00F-X0T 00F-Q Cat. No. 00F-X N.C. spring-clamp 00F-Q0 Also used for test mode function. -

8 Bulletin R IEC Specifications Fused Disconnect Switches For UL Class Fuses and CSA HRCI-J Electrical Ratings Cat. No. R-C0- R-J0- R-J0- CSA Fuse Type/UL Fuse Type Class CC/HRCI-MISC Class J/HRCI-J Class J/HRCI-J Maximum Fuse Cartridge Size Maximum Voltage AC DC (V) (V) Ampere Rating Maximum Short Circuit Prospective Fault Current (ka) Fuse Operating Characteristics Time Delay Non-Time Non-Time Time Delay Delay Delay Time Delay Maximum Hp, Ø AC Maximum Hp, Ø AC Maximum Hp, DC 00V, 0 Hz 0V, 0 Hz 0V, 0 Hz 00V, 0 Hz V, 0 Hz 0V, 0 Hz V DC 0V DC 0. Mechanical Data Cat. No. R-C0-, R-J0- R-J0- Degree of Protection (per IEC 0-) IP0 IP0 Switch Only IP0 IP0 Switch with Terminal Shield & Fuse Carriers Mechanical Endurance Operations,000,000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Nm lb.-in. mm AWG mm AWG # #. # # Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg. lbs. Height Width Depth 0..0 (-/) (-/) (-/) CSA HRCI-MISC fuses must also be UL Listed as Class CC fuses. Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C. No., IEC 0- and UL. A # #. # # (-/) (-/) (-/) B Non-Time Delay... -

9 Bulletin R Specifications, Continued Non-Fused Disconnect Switches For CSA and UL Class Applications Electrical Ratings Cat. No. R-N0- R-N0- Maximum Fuse Cartridge Size 0 0 Maximum Voltage AC DC (V) (V) Ampere Rating 0 0 Maximum Short Circuit Prospective Fault Current (ka) Fuse Operating Characteristics Time Delay Non-Time Delay Time Delay Non-Time Delay Maximum Hp, Ø AC Maximum Hp, Ø AC Maximum Hp, DC 00V, 0 Hz 0V, 0 Hz 0V, 0 Hz 00V, 0 Hz V, 0 Hz 0V, 0 Hz V DC 0V DC.. 0 Power Lost (W) Non-fused disconnect switches must be used with separately installed fuses. When using CSA HRCI-J, HRCI-MISC (also UL Listed as Class CC) or HRCI-T fuses, and UL Class J, CC or T fuses. Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C. No., IEC 0-, UL and UL. Degree of Protection (per IEC 0-) Switch Only Switch with Terminal Shield & Fuse Carriers 00 0 Mechanical Data Cat. No. R-N0- R-N0- Mechanical Endurance Operations,000,000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals N m Lb.-in. mm AWG mm AWG IP0 IP0. # #. # # Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings on.) kg lbs. Height Width Depth Non-fused disconnect switches must be used with separately installed fuses. 0.. (-/) (-/) (-/) All Bulletin R Disconnect Switch Cat. Nos., 0 A A Range Environmental Data Ambient Temperature Open... C (F) + ( +) Enclosed... C (F) 0 +0 ( +) Storage... C (F) 0 + ( 0 +) Altitude (per IEC 0-), C (+ F) Relative Humidity (per IEC 0-) +0 C (+ F) A IP0 IP0.. # #. # #.. (-/) (-/) (-/) B... -

10 Bulletin R IEC Specifications, Continued Fused Disconnect Switches For CSA HRCII-C Fuses Electrical Ratings Cat. No. R-H0- R-H0- CSA Fuse Type HRCII-C HRCII-C Maximum Fuse Cartridge Size 0 0 Maximum Voltage AC (V) Ampere Rating 0 0 Maximum Short Circuit Prospective Fault Current (ka) Maximum Hp, Ø AC Maximum Hp, Ø AC 00V, 0 Hz 0V, 0 Hz 0V, 0 Hz 00V, 0 Hz V, 0 Hz 0V, 0 Hz Degree of Protection (per IEC 0-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Data Cat. No. R-H0- R-H0- Mechanical Endurance Operations,000,000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Nm lb.-in. mm AWG mm AWG IP 0 IP 0. # #. # # Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs. Height Width Depth..0 (-/) (-/) (-/) Based on Allen-Bradley tests in accordance with the requirements as defined in CSA C. No. and IEC 0-. B IP 0 IP 0.. # #. # #..0 (-/) (-/) (-/) B -

11 Bulletin R Specifications, Continued Fused Disconnect Switches For BS Fuses Note: Table continued on pages - -. Electrical Ratings Cat. No. R-B0- R-B- R-B- Fuse Type BS Dimension A A A, A Rated Insulation Voltage (U i ) (V) Rated Conditional Short-Circuit Current (r.m.s.) at V (ka) Rated Operational Current AC-A (l e ) Fuse Links Shorting Links Fuse Links Fuse Links Shorting Links 00/0V 0 Hz 0/00/V 0 Hz 00V 0 Hz 0/0V 0 Hz Rated Operational Current AC-A (l e ) 00/0V 0 Hz 0/00/V 0 Hz 00V 0 Hz 0/0V 0 Hz Rated Thermal Current (l the ) 0 Maximum kw, AC-A Ø 00/0V 0 Hz 0/00/V 0 Hz 00V 0 Hz 0/0V 0 Hz (kw) (kw) (kw) (kw). Maximum Fuse Rating 0 Maximum Motor Circuit Fuse Link 0M M M0 Maximum Fuse Cut-off Current (ka)... Rated Short Time Current, Second (ka) Degree of Protection (per IEC 0-) Switch Only Switch with Terminal Shield & Fuse Carriers.. 0 Mechanical Data Cat. No. R-B0- R-B- R-B- IP 0 IP 0 Mechanical Endurance Operations,000,000,000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Nm lb.-in. mm mm AWG. # #. # # IP 0 IP 0. # #. # # Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs. Height Width Depth 0.. (-/) (-/) (-/) 0.. (-/) (-/) (-/) IP 0 IP 0.. # #. # # (-/) (-/) (-/) A A B Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 0-. -

12 Bulletin R IEC Specifications, Continued Fused Disconnect Switches For DIN Fuses Electrical Ratings Cat No. R-D- R-D- Fuse Type DIN Dimension 00 0, 00 Rated Insulation Voltage (U i ) (V) Rated Conditional Short-Circuit Current (r.m.s.) at V (ka) 0 0 Rated Operational Current AC-A (l e ) Fuse Links Fuse Links 00/0V 0 Hz 0/00/V 0 Hz 00V 0 Hz 0/0V 0 Hz Rated Operational Current AC-A (l e ) 00/0V 0 Hz 0/00/V 0 Hz 00V 0 Hz 0/0V 0 Hz Rated Thermal Current (l the ) 0 Maximum kw, AC-A Ø 00/0V 0 Hz 0/00/V 0 Hz 00V 0 Hz 0/0V 0 Hz (kw) (kw) (kw) (kw) Maximum Fuse Rating Maximum Motor Circuit Fuse Link Maximum Fuse Cut-off Current (ka) 0 Rated Short Time Current, Second (ka) Mechanical Data Cat. No. R-D- R-D- Degree of Protection (per IEC 0-) Switch Only Switch with Terminal Shield & Fuse Carriers Mechanical Endurance Operations,000,000 Operating Torque (Maximum) Terminal Capacity Power Terminals Auxiliary Contact Terminals Nm lb.-in. mm AWG mm AWG IP 0 IP 0. # #. # # Maximum Number of Auxiliary Circuits Approximate Weight Minimum Enclosure Size Approximate dimensions in millimeters (inches) Switch Dimension Reference (See dimension drawings.) kg lbs. Height Width Depth..0 (-/) (-/) (-/) IP 0 IP 0.. # #. # #..0 (-/) (-/) (-/) Fuses must be selected with regard to the maximum prospective fault current of the system and the maximum cut-off current of the fuse when subjected to that maximum fault current. The maximum fuse cut-off current as specified for each disconnect switch must not be exceeded. Based on Allen-Bradley tests in accordance with the requirements as defined in IEC 0-. B B -

13 Bulletin R Specifications, Continued Wiring Schematic -

14 Bulletin R IEC Approximate Dimensions Αππροξιματε Διμενσιονσ Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Disconnect Switch Dimension References A, A, B and B (0 A and 0 A) Disconnect Switch Approximate Dimensions mm (in) Dimension Reference H W D A B C E FD A (-/) (-/) () 0 (-/) (-/) (-/) (-/) -M, -# A (-/) (-/) 0 (-/) 0 (-/) (-/) (-/) (-/) -M, -# B (-/) (-/) (-/) 0 (-/) (-/) N/A N/A -M, -# B (-/) (-/) (-/) 0 (-/) (-/) N/A N/A -M,-# Mounting holes for backward compatibility with Bulletin R legacy switches. Operating Handles Cat. No. R-HS /HST -0

15 Bulletin R Approximate Dimensions, Continued Disconnect Switch Dim. Ref.: A, A, B, B (0 A and 0 A) Enclosure and Operating Handle Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Enclosure Installation Dimensions Cat. No. R-C0- Dimension Reference A B C D E F Maximum Minimum Minimum Maximum Minimum Minimum Minimum Maximum A (-/) (-/). (- /) (-/) (-/) (-/). (/) / (/) R-J0- A (-/) (-/) (-/) (-/) (-/) (-/). (/) / (/) B (-/) (-/). (- /) (-/) (-/) (-/). (/) / (/) R-J0- R-N0- B (-/) (-/) (-/) (-/) (-/) (-/). (/) / (/) -

16 Bulletin R IEC Approximate Dimensions, Continued Universal Internal Handle Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. -

17 Bulletin R Approximate Dimensions, Continued Enclosure Installation Dimensions Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. -

18 Bulletin R IEC Applications Proper Selection of Disconnect Switches Applications Within Canada and the United States General The requirements for disconnect switches used in motor branch circuits rated 00V and less are defined in Article 0, Part J of the U.S. National Electrical Code (NEC), NFPA0. Canadian Electrical Code (CEC) requirements are very similar in the area of motor branch circuit disconnect requirements. For simplicity, we will treat the NEC and CEC requirements as being the same and reference specific sections of the U.S. National Electrical Code. The requirements for properly sizing a disconnect switch are dependent on the type of application. The NEC refers to two types of applications: single motor and combination loads. A combination load consists of an application where two or more motors are used together or where one or more motors are used in combination with other loads, such as resistance heaters. Single Motor Applications Section 0- Paragraph (a) states that the disconnect switch must have an ampere rating of at least % of the full-load current rating of the motor. Example : For a motor with a full-load current of A, the disconnect switch must be rated at least. A ( x.). If the disconnecting means under evaluation is rated in horsepower, the selection of the disconnect switch is even more straightforward; a disconnect switch must have a horsepower rating equal to, or greater than the horsepower rating of the motor at the applicable voltage. Example : For a motor with a Hp rating at 0V AC, the disconnect switch must be rated at least Hp at 0V AC. If the disconnect switch is rated in horsepower, and UL Listed, UL Component Recognized, or CSA Certified, it will meet the requirements for the % full load current rating stipulated by the NEC. Combination Load Applications Section 0- Paragraph (c) addresses the rating of the disconnecting means for combination loads. This paragraph essentially requires that the loads that may be simultaneous on a single disconnecting means be combined to provide equivalent fullload and locked-rotor currents for what is then to be considered as a single motor for the purpose of selecting the appropriate disconnecting means. This means that it is necessary to identify the particular combination of connected loads which can be operating simultaneously and will result in the maximum full-load and lockedrotor current sums. The individual full-load current values are to be selected from Tables 0-, 0-, or 0- and the locked-rotor values are to be from Table 0-. The equivalent single motor full-load current is the sum of the simultaneously operating motor full-load currents and the rating in amperes of other loads operating at the same time. The equivalent locked-rotor current is the sum of the simultaneously started motors locked-rotor currents and the full-load currents of the remaining operating motor and non-motor loads. The disconnecting means shall have a current rating equal to or greater than % of the equivalent single motor full-load current and have a horsepower rating equal to or greater than the horsepower rating determined from the equivalent locked-rotor summation. Consider the following 0V application: Load Hp Full-Load Current A Motor. (simultaneous) Motor.0 (not included) Motor.0 (simultaneous) Motor 0.0 (simultaneous) Other.0 (simultaneous) Total Equivalent. (simultaneous) Motor is not included in the total since it cannot operate simultaneously with the other motors, therefore, the disconnect switch must be rated at least A (. x.). Consider now the locked-rotor current analysis for the same application: Load Hp Full-Load Current A Motor (.FLA). (simultaneous) Motor.0 (not included) Motor.0 (simultaneous) Motor 0.0 (simultaneous) Other.0 (simultaneous) Total Equivalent 0. (simultaneous) Note again that Motor cannot operate simultaneously with the other loads. The largest equivalent locked-rotor current occurs when motors and start together while the other loads marked simultaneous are already operating. Since Motor is not starting with Motors and, its full-load current will be added to the total instead of its locked-rotor current. Table 0-, which provides the correlation between locked-rotor currents and Hp ratings, shows that a 0 Hp rating is the equivalent for 0. locked-rotor amperes. Therefore, the disconnect selected for this application must have a current rating of at least A and a Hp rating of at least 0 Hp. In this case a Bulletin R rated for 0 A and 0 Hp at 0V would be an appropriate choice. What can be seen from this analysis is that, depending upon the number of motors that can start simultaneously, the actual size of the required disconnect is sometimes determined by the equivalent full load current ( A) and other times by the equivalent horsepower determined from the lockedrotor analysis (0 Hp). Applications Outside the United States and Canada General Disconnect switches designed to IEC Standards and used in applications outside of North America are selected based on the ampere, horsepower, or kilowatt rating of the disconnect switch, under various utilization categories. Utilization categories for disconnect switches are as follows: Nature of Current AC Utilization Category Frequent Operation Infrequent Operation AC-0A AC-0B AC-A AC-A AC-B AC-B AC-A AC-B Typical Applications Connecting and disconnecting under no load conditions Switching of resistive loads including moderate overloads Switching of mixed resistive and inductive loads, including moderate overloads Switching of motor loads or other highly inductive loads The use of these utilization categories is not permitted in the U.S. For any application, the disconnect switch rating (A. Hp, or kw) must be greater than or equal to the application full-load current or power (Hp or kw), in the appropriate utilization category. Example : For a 0V 0 Hz distribution application (AC-A), with a A full load current, the disconnect switch must be rated at least A at 0V 0 Hz for use in AC-A applications. Example : For a V 0 Hz motor application (AC-A), with a kw rating, the disconnect switch must be rated at least kw at V 0 Hz for use in AC-A applications. -

19 Fuse Description With Bulletin R Fused Disconnect Switches Bulletin R Fused Disconnect Switches have been designed to accept a variety of fuses for worldwide application flexibility. Following is a brief summary of typical fuse specifications, where the fuses are typically used, and which Bulletin R disconnect switches will accommodate each fuse type. Fuse manufacturers should be contacted for more specific information about each fuse type. Fuses are not available from Rockwell Automation. BS Fuses ( A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. Bulletin R Fuse Description IEC fuse type: Fuse-link for bolted connection Voltage rating: 0/0V AC Interrupting rating: 0 ka Standard cartridge sizes: A, A, A, A, B, B, B, B Typical ampere ratings: A 00 A Construction: Blade type for bolted connection Can be installed on Bulletin R disconnect switch Cat. Nos: RNA0P, NA00P, NA00P, NA0P, NA00P, NB00P, NB00P Where used: United Kingdom, Australia, New Zealand, Asia Standard cartridge size A Standard cartridge sizes A, A, A Standard cartridge sizes B, B, B, B Ampere Dim. Ref. Range A B D E F G H K A 0.0 (-/).0 (/).0 (-/). (/) 0.0 (/).0 (-/).0 (/).0 (/) Dim. Ref. Ampere Range A B D E F G H J K A 0.0 (-/).0 (/).0 (-/).0 (/).0 (/).00 (-/).0 (/). (/).0 (/) A.0 (-/).0 (/).0 (-/).0 (/).0 (/).00 (-/).0 (/). (/).0 (/) A (-/).0 (-/).00 (-/). (/).0 (/).0 (-/.0 (/).0 (/).0 (-/) Dim. Ref. Ampere Range A B D E F G H J M B (-/).0 (-/).0 (-/). (/).0 (/).00 (-/).0 (/).0 (/).0 (-/) B (-/).0 (-/).0 (-/). (/).0 (/).00 (-/).0 (/).0 (/).0 (-/) B 0.00 (-/).00 (-/).0 (-/).0 ().0 (/).00 (-/).0 (/).0 (/).00 (-/) B (-/). (-/).0 (-/).0 ().0 (/).00 (-/).0 (/).0 (/).0 (-/) -

20 Bulletin R IEC Fuse Description, Continued DIN Fuses (0 A shown) Dimensions in millimeters only. Dimensions are not intended to be used for manufacturing purposes. IEC fuse type: Fuse-link with blade contacts Voltage rating: 0/0V AC Interrupting rating:,000 A Standard cartridge sizes: 00, 0, and Typical ampere ratings: 00 A Construction: Blade type Can be installed on Bulletin R disconnect switch Cat. Nos: RND0P, NDP, ND0P, ND00P Where used: Europe, South America, Middle East and India Size Max. rated current a a a a b (min.) d e (max.) e (max.) e e ±0. f ±. ±. ±. ± ±. 0 0 ± ±. 0 ±. ±. ± ±. ±. ± With Bulletin R Fused Disconnect Switches, Continued CSA HRCI and UL Class Fuses ( A shown) CSA HRCI and UL Class Fuses ( A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. UL fuse type: Class CC CSA fuse type: HRCI-MISC Voltage rating: 00V AC Interrupting rating: 00,000 A Standard cartridge sizes: 0 A Typical ampere ratings: 0 A Construction: Ferrule type Can be installed on Bulletin R disconnect switch Cat. No: R-NC00P Where used: North America CSA HRCI and UL Class Fuses (0 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. CSA fuse type: HRCI-J UL fuse type: Class J Voltage rating: 00V AC Interrupting rating: 00,000 A Standard cartridge sizes: 0 A, 0 A, 0 A, 00 A and 00 A Typical ampere ratings: -00 A; Blade type for bolted connection Can be installed on Bulletin R disconnect switch Cat. Nos: R- NJ00P, NJ00P, NJ0P, NJ00P, NJ00P Where used: North America -

21 Bulletin R Fuse Description, Continued CSA HRCII Fuses (0 A shown) Dimensions in millimeters (inches). Dimensions are not intended to be used for manufacturing purposes. CSA fuse type: HRCII-C Voltage rating: 00V AC Interrupting rating: 00,000 A Standard cartridge sizes: 0 A, 0 A, 0 A, 00 A and 00 A Typical ampere ratings: 00 A Construction: Blade type for bolted connection Can be installed on Bulletin R disconnect switch Cat. Nos: R-NA00P, NA00P, NH0P, NH00P, NH00P Where used: Canada Standard Cartridge Sizes 0 A, 0 A, and 0 A Standard Cartridge Size 00 A Standard Cartridge Size 00 A Range A B C D E F G H J 0 0. (-/).0 (-/) 0. () 0. (/). (/). (/). (/). (/). (/) 0. (-/).0 (-/) 0. () 0. (/). (/). (/). (/). (-/). (/) 0. (-/). (-/) 0. (-/). (-/).0 (/). (/). (/). (-/). (/) 00. (-/). (-/). (). (-/).0 (/). (/). (/). (/) (-/). (-/). () 0. (-/). (). (/). (/). (). (/) (-/). (-/). (). (). ().0 (/). (/). (). (/) -

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IEC Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC

More information

194R J S TY N1

194R J S TY N1 Bulletin R IE Fused and Non-Fused Disconnects, & A Product Selection omplete UL/SA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA

More information

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects

Bulletin 194R TABLE OF CONTENTS Bulletin 194R IEC Fused and Non-Fused Disconnects 4 Bulletin 194R TABLE OF CONTENTS Bulletin 194R 20 A 400 A Sizes Open or Enclosed Switches d Switch Versions: BS88 DIN CSA HRCII-C CSA HRCI-J UL Class J UL Class CC Non-d Switches Operating Handle Ingress

More information

UL Enclosed Disconnect Switches (Fused and Non-Fused)

UL Enclosed Disconnect Switches (Fused and Non-Fused) Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66

More information

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects Bulletin R IE Fused and Non-Fused Disconnects, & A Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects A A Sizes Fused switch versions: - BS - DIN - SA HRII- - SA HRI-MIS - UL lass

More information

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories. Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! To learn the basic differences between control, load and fusible

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Big performance in a small package

Big performance in a small package Series Fusible & Non-fusible Sprecher + Schuh s series of fused and non-fused disconnect switches comply with service entrance requirements. This family of rod operated switches is suitable for applications

More information

Big performance in a small package

Big performance in a small package Series usible & Non-fusible 100 400A Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or usible Which is Best or Your Application? Application Data Typical Control Switch

More information

Big performance in a small package

Big performance in a small package Series 11 Fusible up to 800A & Non fusible Disconnect Switches up to 1200 Amps Suitable as a U98 Service Entrance Disconnecting Means TIP! Manual Switching Devices: Control, oad or Fusible Disconnect Switches

More information

Big performance in a small package

Big performance in a small package 11 Series 11 Fusible up to 800A & Non fusible up to 1200 Amps Suitable as a Service Entrance ing Means TIP! Manual Switching Devices: Control, oad or Fusible Which is Best For Your Application? Application

More information

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊

UL Class J and CSA HRCI-J Fuses ➋. obsolete. CSA HRCII-C Fuses. Maximum Horsepower ➊ Series U/CSA Fused Amp Rating 1 Ø (60Hz) Maximum Horsepower ➊ Three Phase (60Hz) DC Switch (typical) (A) 120V 240V 200V 240V 460V 600V 125V 250V Catalog Number Price U Class J and CSA HRCI-J Fuses ➋ 30

More information

Rotary Disconnect Switches, Bulletin 194R

Rotary Disconnect Switches, Bulletin 194R ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION Rotary Disconnect Switches Bulletin 194R NOTICE: The specification guidelines in this document are intended to aid in the specification

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate

More information

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers Bulletin 1494D Fixed Depth Flange Mounted Circuit Breaker Operating Mechanism Industrial rated circuit breaker operating mechansim pre-assembled

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web: -

Fusible. Fusible disconnect switches 30A 1200A, 600VAC. Phone: Fax: Web:  - disconnect A 1200A, 600VAC Disconnect Disconnect ABB PowerLine includes seven different amperage sizes from A to 1200A. All ABB fusible are designed to meet customer requirements in terms of high interrupting

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin Number 140M Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Overview 3 Catalog Number Explanation

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753 Depth x  Width x 2.375 Height 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

For many applications

For many applications Series 40 Amp Rugged and dependable 40 amp switches for industrial applications Sprecher + Schuh s rugged rotary cam switches are available for most control and load applications up to 40 amps. A well

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

CENTERLINE 2100 Motor Control Centers

CENTERLINE 2100 Motor Control Centers TECHNICAL DATA CENTERLINE 2 Motor Control Centers Instantaneous Trip Motor Circuit Protectors (MCP) in Combination NEMA Starter, Soft Starter (SMC) and Variable Frequency AC Drive Units 1A Frame Instantaneous

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

600V, Non-Fusible, (3-Pole, 3 Phase)

600V, Non-Fusible, (3-Pole, 3 Phase) 0V, Non-Fusible, (3-Pole, 3 Phase) ulletin 1494G/1494GX1494GY Non Fusible 0 A switch ratings 0V: 3-pole, 3-phase and 6-pole, 3-phase versions versions only Type 3R/4/12 (painted metal), Type 4/4X (stainless

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES

PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES PRODUCT PROFILE 1494C CABLE-OPERATED, FLANGE-MOUNTED DISCONNECT SWITCHES Rockwell Automation expands its new line of Allen-Bradley Bulletin 1494C Cable-Operated, -Mounted Switches that meet industrial

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

FUSIBLE DISCONNECT SWITCHES

FUSIBLE DISCONNECT SWITCHES FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses Technical Data 10789 BUSSMANN SERIES Next generation Compact Circuit Protector (cat. no. CCP2) Contents Page 2011/65/EU CCP2 switch and specifications.... 2-3 Catalog numbers.... 4 Conductor information

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

SPEEDFAX TM 2011 Disconnect Switches Contents

SPEEDFAX TM 2011 Disconnect Switches Contents SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection

More information

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz Catalog Number Explanation Open Controllers a Bulletin Number Solid-State Controller B H H B B B B B B B B B B B B B Solid-State Controller and Isolation Contactor (enclosed only) b Controller Ratings

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

1492-CB 1492-GH 1492-GS

1492-CB 1492-GH 1492-GS 1 The Allen-Bradley Line of Devices Allen-Bradley offers 3 different lines of Circuit Breakers (Supplementary Protectors) and a line of branch circuit rated Fuse Holders. Allen-Bradley Thermal Magnetic

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Compact Circuit Protector

Compact Circuit Protector Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information