3. Coils shall be of molded construction

Size: px
Start display at page:

Download "3. Coils shall be of molded construction"

Transcription

1 .7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application Magnetic motor starters are designed for across-the-line control of squirrel cage motors. Starters can be furnished for non-reversing, reversing and twospeed applications. Starter Types ECN0 Freedom NEMA Non-Reversing. ECN0 Freedom NEMA Reversing. ECT0 IT. NEMA Non-Reversing. ECT0 IT. NEMA Reversing. Enclosures Type : General Purpose. Type R: Rainproof. Type 4: Watertight, Painted Steel. Type 4X: Watertight, Stainless Steel. Type : Dust-tight Industrial Use. Type 7/9: Explosion Proof. Ratings See Section.. Typical Electromechanical motor control are Eaton s Cutler-Hammer Types ECN0 and ECN0. Freedom Non-Reversing Starters. Across-the-line magnetic starters for motors up to hp, volts are Cutler-Hammer Type ECN0.. Magnetic starters through NEMA Size 8 are equipped with double break silver alloy contacts. The starter must have straight-through wiring.. Coils shall be of molded construction through NEMA Size 8. All coils are color coded through Size and permanently marked with voltage, frequency and part number. 4. Overload relays are an ambient compensated bimetallic type with interchangeable heater packs. Overloads have ±% adjustability, single-phase sensitivity, an isolated alarm contact and manual or automatic reset.. NEMA Size 00 starters are suitable for the addition of eight snapon external auxiliary contacts of any arrangement normally open or normally closed. Size 8 starters shall be suitable for the addition of up to eight external auxiliary contacts of any arrangement normally open or normally closed. Freedom Reversing Starters. Reversing magnetic starters for motors up to 900 hp, volts are Cutler-Hammer Freedom Series Type ECN0.. Reversing starters consist of two contactors and a single overload relay assembled together. The contactors are mechanically and electrically interlocked to prevent line shorts and prevent energizing both contactors simultaneously.. Magnetic starters through NEMA Size 8 are equipped with double break silver alloy contacts. The starter must have straight-through wiring. 4. Coils are of molded construction through NEMA Size 8. All coils are color coded through Size and permanently marked with voltage, frequency and part number.. Overload relays are ambient compensated bimetallic type with interchangeable heater packs. Overloads have ±% adjustability, single-phase sensitivity, and isolated alarm contact and manual or automatic reset.. NEMA Size 00 starters are suitable for the addition of eight snap-on external auxiliary contacts of any arrangement normally open or normally closed. Sizes 8 starters are suitable for the addition of up to eight external auxiliary contacts of any arrangement normally open or normally closed. IT. Non-Reversing Starters. IT. across-the-line magnetic starters for motors up to 00 hp, volts are Eaton s Cutler-Hammer Type ECT0.. IT. starters are equipped with silver alloy contacts.. All IT. coils are 0 Vdc. Coils are replaceable through Size. 4. IT. starters come standard with an SSOL relay with a.: adjustment range. They also have phase loss protection, an alarm contact, selectable manual or automatic reset, test features and an alarm without trip configuration.. Auxiliary contacts are all topmount style. Size 0 IT. Reversing Starters. IT. reversing magnetic starters for motors up to 00 hp, volts are Eaton s Cutler-Hammer Type ECT0.. Reversing starters consist of two contactors and a single overload relay assembled together. The contactors are mechanically and electrically interlocked to prevent line shorts and prevent energizing both contactors simultaneously.. IT. starters are equipped with silver alloy contacts. 4. All IT. coils are 0 Vdc. Coils are replaceable through Size.. IT. starters come standard with an SSOL relay with a.: adjustment range. They also have phase loss protection, an alarm contact, selectable manual or automatic reset, test features and an alarm without trip configuration.. Auxiliary contacts are all topmount style. Size 0 Maximum Stand Auxiliary 4 Maximum Stand Auxiliary 4 Maximum Logic Level 4 Maximum Logic Level 4 CA08E

2 .7- Motor Starters & Contactors Low Voltage Enclosures Catalog Numbering System January 00 Sheet Table.7-. Enclosed Control Catalog Numbering System NEMA Design N = Freedom T = IT. Class 0 = Contactors 0 = Reversing Contactors 0 = FVNR Starter, Non-Combination 0 = Reversing, Non-Combination 07 = FVNR Non-Combination, with CPT 08 = Single-Phase FVNR (Freedom Only) = Combination with Disconnect Switch 7 = Reversing, Combination with Disconnect Switch 8 = Combination with Disconnect Switch, with CPT = Combination with HMCP = Reversing, Combination with HMCP = Combination with HMCP with CPT = Multispeed SW Non-Combination 4 = Multispeed SW CT or VT Non-Combination = Multispeed SW CH Non-Combination = Multispeed with Disconnect Switch, SW = Multispeed with Disconnect Switch, SW CT or VT = Multispeed with Disconnect Switch, SW CH = Multispeed with HMCP, SW = Multispeed with HMCP, SW CT or VT 4 = Multispeed with HMCP, SW CH 4 = Autotransformer, Non-Combination 4 = Autotransformer, with Disconnect Switch 44 = Autotransformer, with HMCP 4 = Part-Winding, Non-Combination 4 = Part-Winding, with Disconnect Switch 47 = Part-Winding, with Thermal-Magnetic Circuit Breakers 48 = Y-D, Open Transition, Non-Combination 49 = Y-D, Open Transition, with Disconnect Switch 0 = Y-D, Open Transition, with Thermal-Magnetic Circuit Breakers = Y-D, Closed Transition, Non-Combination = Y-D, Closed Transition, with Disconnect Switch = Y-D, Closed Transition, with Thermal-Magnetic Circuit Breakers = Autotransformer Pump Panel, Disconnect Switch = Autotransformer Pump Panel, HMCP 4 = Part-Winding Pump Panel, Disconnect = Part-Winding Pump Panel, HMCP 8 = Duplex, Non-Combination 9 = Duplex, with Disconnect Switch 70 = Duplex, with HMCP ECN A A F - NEMA Size A = 00 0 = 0 = = = 4 =4 = = 7 =7 8 =8 9 =9 For IT., IEC and NEMA Starters, add an th character for the corresponding overload selection. For non-combination contactors and starters, include the letter (A) as the th character. A = None B = A/0 V R C = A/ V R D = 0 A/0 V R E = 0 A/ V R F = A/0 V R A = None B = A C = 7 A D = A E = A F = 0 A Cover Control (Starters Only) (See Tables.7-4 and.7- on Page.7-) Coil Voltage and/or Control Transformers (See Tables.7- and.7- Below) Modification Codes Disconnect Fuse Clip Ratings G = A/ V R H = 00 A/0 V R J = 00 A/ V R K = 0 A/0 V R L = 0 A/ V R M = A/0 V R HCMP or Breaker Ratings G = A H = A J = 0 A K = 0 A L = A M = 800 A Enclosure Types = Type General Purpose = Type R Rainproof = Type 4 Watertight (Painted Steel) 4 = Type 4X Watertight (Stainless Steel) = Type 4X Corrosion (Non-Metallic) = Type 7/9 Bolted Hazardous Location 7 = Type 7/9 Threaded Hazardous Location 8 = Type Dust-Tight N = A/ V R P = 800 A/ V L Q = A/ V L R = A/ V L S = 000 A/ V L T = by N = 0 A P = A Q = 000 A R = 00 A T = by Table.7-. Magnet Coil Codes (System Voltage) Code Voltage Code Voltage A B C D E G H J K L M /0 /0 0/0 0/0 480/0 4/0 7/0 0/0 08/0 0/0 77/0 08 0/0 0/0 0/0 4/0 When control power transformer Modification Codes (CI CII) are used, pick the system (primary) voltage from this chart. See Table.7-. Note: All IT. contactors and starters are furnished with Vdc coil and control power supply. The eighth digit Q denotes separate Vdc control source. P Q R S T U V W X Y Z Vdc Vdc 48 Vdc / Vdc /0 /0 /0 48/0 4 /0 48/0 By Table.7-. Control Power Transformer Codes (System Voltage) Code Primary Secondary B C D E H L M P Q R S T U V W X Y Z 0/480 0/4 Wired for 0 V 0/480 0/4 Wired for 0 V 7/0 0/0 08/0 77/0 0/0 4/0 /0 08/0 0/480 0/4 Wired for 0 V 0/480 0/4 Wired for 0 V 7/0 77/0 0/0 4/0 0/480/ Wired for 480 V 0/480/ Wired for 480 V By /0 /0 /0 /0 /0 /0 /0 /0 /0 /0 Note: Use when ordering classes with CPT installed (i.e., ECN 8) and when using Modification Codes CI CII. CA08E

3 January 00 Sheet 8 Motor Starters & Contactors Low Voltage Enclosures Catalog Numbering System.7- Table.7-4. Cover Control Non-Reversing Code A B C D E F G H J K L M N P Q R S T U V W X Z None Start/Stop Pushbuttons Start/Stop Pushbuttons, Run (R) Pilot Light Start/Stop Pushbuttons, Run (R), Off (G) Pilot Lights On/Off Pushbuttons On/Off Pushbuttons, Run (R) Pilot Light On/Off Pushbuttons, Run (R), Off (G) Pilot Lights Hand/Off/Auto Selector Switch Hand/Off/Auto Selector Switch, Run (R) Pilot Light Hand/Off/Auto Selector Switch, Run (R), Off (G) Pilot Lights Start Pushbutton On Pushbutton Off Pushbutton Run-Red Pilot Light Off-Green Pilot Light Run (R) - Off (G) Pilot Lights Start/Stop Selector Switch Start/Stop Selector Switch, Run (R) Pilot Light Start/Stop Selector Switch, Run (R), Off (G) Pilot Lights On/Off Selector Switch On/Off Selector Switch, Run (R) Pilot Light On/Off Selector Switch, Run (R), Off (G) Pilot Lights By Starters only contactor cover control: use Modification Codes. Table.7-. Cover Control Non-Reversing (Use for Class 0,, 7, 0,, ) Code A B C D E F H J K P Q R V W X Z None Forward/Reverse/Stop Pushbuttons Forward/Reverse/Stop Pushbuttons, Red Pilot Lights Forward/Reverse/Stop Pushbuttons, Red, Green Pilot Lights Up/Stop/Down Pushbuttons Up/Stop/Down Pushbuttons, Red Pilot Lights Forward/Off/Reverse Selector Switch Forward/Off/Reverse Selector Switch, Red Pilot Lights Forward/Off/Reverse Selector Switch, Red, Green Pilot Lights Red Pilot Lights Green Pilot Light Red, Green Pilot Lights Open/Off/Close Selector Switch Open/Off/Close Selector Switch, Red Pilot Lights Open/Off/Close Selector Switch, Red, Green Pilot Lights By Starters only contact or cover control: use Modification Codes CA08E

4 January 00 Sheet 7 Motor Starters & Contactors Low Voltage Motor Starters Electromechanical Freedom Line General.- Freedom IEC AE7KNS0AFE IEC Size K, 0 hp/ V Product NEMA ANDN0AB NEMA Size The Freedom Series starters and contactors listed in this catalog feature a compact, space-saving design, using state-of-the-art technology and the latest in high strength, impact and temperature-resistant insulating materials. Starters and contactors are available in two rating/configuration styles NEMA (National Electrical Manufacturers Association) and IEC (International Electrotechnical Commission). The NEMA devices are sized based on traditional NEMA classifications and the IEC devices on international ratings. Internationally rated starters and contactors, as compared to NEMA devices, generally are physically downsized to provide higher ratings in a smaller package. However, electrical load/life ratings are correspondingly reduced. Careful consideration should be given to the selection of the proper device for a specific application. Parameters, such as type of load, severity of duty, electrical load/life cycles required, etc., must be evaluated before choosing either the IEC or NEMA designs. Since the IEC devices are typically smaller than the equivalent NEMA device, there is a cost advantage over the NEMA starters and contactors. Application The Freedom to Choose the Right Product for the Application Eaton has been supplying quality industrial control products for more than years the Freedom Series of Contactors and Starters continue in this tradition. They offer something no other electrical control line in the world can the Freedom to choose contactors and starters designed to either NEMA or IEC standards from one family. There are many difficult choices to be made today in matching electrical control to a specific application, but the Cutler-Hammer Freedom Series makes it easy. Features Freedom Family A single family of contactors and starters suitable for application in both the IEC and NEMA markets. Two lines, One family the best of both worlds. Adjustable Bimetallic Ambient Compensated Overload relays with interchangeable heater packs available in three basic sizes, covering applications up to 900 hp reducing the number of different contactor/overload relay combinations that have to be stocked. Fixed heater overloads are optional. A full line of snap-on accessories common to both IEC and NEMA devices top and side mounted auxiliary contacts, solid-state and pneumatic timers, etc. Straight-through wiring line lugs at top, load lugs at bottom. Horizontal or vertical mounting on upright panel for application freedom. Screw type power terminals have captive, backed-out self-lifting pressure plates with ± screws reduced wiring time. Accessible terminals for easy wiring. Optional fingerproof shields available to prevent electrical shock. Top located coil terminals convenient and readily accessible. 4 mm contactor magnet coils have three terminals, permitting either top or diagonal wiring easy to replace European or U.S. style starters or contactors without changing wiring layout. Encapsulated dual voltage/frequency magnet coils permanently marked with voltage, frequency and part number. NEMA Sizes 00 0 have non-encapsulated coils as standard. Designed to meet or exceed NEMA, UL, CSA, IEC, VDE, BS and other international standards and listings. Freedom NEMA Freedom NEMA contactors and starters are designed to NEMA standards and are extremely rugged products and built for any application. Their long electrical/mechanical life is extended through easy maintainability. Meet and exceed all NEMA, UL and CSA standards. Sized based on standard NEMA classifications. Designed and built for a variety of demanding applications. Easy coil change and inspectable/ replaceable contacts. Adjustable/interchangeable heater packs for flexibility. Available in Open and NEMA, R, 4/4X and enclosures. Freedom IEC Features Freedom IEC contactors and starters are designed to IEC standards and comply with the International Standard IEC IEC products are a perfect choice when electrical and mechanical application parameters are known. They are typically smaller in size and provide higher ratings in a smaller package. They are available in sizes to match the contactor to the application. Complies with IEC , EN, CENELEC, UL and CSA standards. Sizes of contactors through 900 hp. DIN rail mountable through 0 hp. Adjustable bimetal overload relays fixed or interchangeable heater. Available in Open and NEMA, R, 4/4X and enclosures CA08E

5 .- Motor Starters & Contactors Low Voltage Motor Starters Electromechanical Freedom Line General January 00 Sheet Freedom Enhancements mm Contactor Accessible Power Terminations to Facilitate Installation The mm contactor housing has been completely redesigned to open up the line/load terminal access area, allowing better visibility when wiring. This also aids in maintenance. IP0 fingerproofing is available through add-on shields. This change affects NEMA Sizes and. Load Lugs on Overload Relay Base The load lugs have been moved from the heater pack housing to the sensor base of the A and 7 A overload relays. This permits wiring of the starter prior to heater pack installation. These overload relays are used on NEMA Sizes 00 and 8. Auxiliary Contact Markings CENELEC EN00 All auxiliary contact blocks are identified by a two-digit contact configuration code. Auxiliary contact terminals are also identified by a two-digit number in accordance with International Standards approved by CENELEC. Auxiliary Contact Ratings All side and top auxiliary contact blocks are now rated NEMA/UL P0 dc ratings and IEC 947 AC-/DC- ratings. Larger IEC Contactors There are three additional frame sizes a 0 mm contactor (CET and U) rated 0 and hp respectively; a 80 mm contactor rated 0 hp at V; and a mm contactor rated 900 hp at V. New Class and 0 Heater Packs Because of improvements in the overload relays, the Class and 0 interchangeable heater packs have been modified. They can be used with the new overload relays (Series B) directly or with the existing relays (Series A) when using an adapter lug kit. Series B A Overload AE7/7 IEC Fixed Heater Starters, IEC Completely assembled IEC starters can be ordered in non-reversing and reversing, open or enclosed. This starter line is composed of CE contactors and C fixed heater overload relays. AE7 Fixed Heater IEC Starter Size K Easy Magnet Coil Change The mm contactor and the connections on the 4 and mm starters have been modified to allow easy coil changes at the distributor or in the field. Standards and Certifications Standard: Designed to meet or exceed UL, NEMA, IEC, CSA, VDE and BS. UL listed: UL File #E49, Guide #NLDX Open; UL File #E7 Enclosed Combination Motor Controllers; UL File #E9 Enclosed Non-Combination Motor Controllers; UL File #E9 Enclosed Power Conversion Equipment. CSA certified: CSA File #LR, Class #4 Open and NEMA Enclosed. IEC: IEC , Sizes 8 (A S); IEC 8, Sizes T Z; IEC 947 Pending. Certified Type Coordination Cutler-Hammer Freedom Series IEC starters and NEMA starters are now UL certified to achieve IEC 947 Type coordination against,000 A short circuit fault currents. Any brand of properly selected fuse can be used. Type coordination means that the starter will be suitable for further use following a short circuit fault. ISO 9000 Certification When you turn to Eaton s Cutler- Hammer products, you turn to quality. The International Standards Organization (ISO ) has established a series of standards acknowledged by 9 industrialized nations to bring harmony to the international quest for quality. The ISO certification process covers 0 quality system elements in design, production and installation that must conform to achieve registration. This commitment to quality will result in increased product reliability and total customer satisfaction. Short Circuit Protection Fuses and Inverse-Time Circuit Breakers may be selected per Article 4, Part D of the National Electrical Code to protect motor branch circuits from fault conditions. If higher ratings or settings are required to start the motor, do not exceed the maximum as listed in Exception No., Article 4-. Contactor Terminal Markings Contactors are identified by a two digit number in accordance with International Standards approved by CENELEC (European Committee for Electrotechnical Standardization). This distinctive number is marked on the top nameplate and designates the type and quantity of built-in auxiliary contacts. The first digit indicates the quantity of NO and the second digit indicates the quantity of NC contacts. Example: E indicates a contactor with NO and no NC auxiliary contacts factory supplied. In addition, all terminals conform to both CENELEC and NEMA requirements. Auxiliary contact terminals use the first digit to indicate location and the second digit to indicate status (- means NC and -4 means NO). Example: -4 indicates the first auxiliary contact and it is a NO. -Pole A A A L L Figure.-. Contact Example When Supplied L T T T 4 4 CA08E

6 January 00 Sheet 9 Motor Starters & Contactors Low Voltage Motor Starters Electromechanical Freedom Line Technical Data NEMA Contactors and Starters.- NEMA Sizes 00-8 Table.-. ac Coil Data NEMA Sizes Motor Voltage Maximum hp Rating -/ -/ 7-/ 7-/ % of rated coil voltage. P.U. Volts P.U. Sealed D.O. Volts Maximum Operation Cold Hot Var VA Watts Var VA Watts Cold Hot Rate Operations/Hour P.U. Time ms 74% 78% % 4%,000 74% 78% % 4%,000 74% 78% % 0%, % 78% % 0%, % 7% % % 7,00 4 7% 7% % %, % 77% % 4%,0 7% 7% % 7% % 7% D.O. Time ms General Coil Data Coil Offering tape wound: NEMA Sizes 00 0 UL Insulation Rating: Class (B) Coil Offering encapsulated: NEMA Sizes UL Insulation Rating: Class (A) Coil Offering encapsulated: NEMA Sizes 4 UL Insulation Rating: Class (F) Operational Limits: 8% to % of rated voltage ac 80% to % of rated voltage dc Table.-. Coil Data Notes P.U. Pickup time is the average time taken from closing of the coil circuit to main contact touch. D.O. Dropout time is the average time taken from opening of the coil circuit to main contact separation. Cold Coil data with a cold coil. Hot Coil data with a hot coil. All data is based on a standard contactor with no auxiliary devices and a Vac or Vdc magnet coil. Coil data has a ±% range depending on the application, therefore specific data may vary. 4 CA08E

7 .-4 Motor Starters & Contactors Low Voltage Motor Starters Electromechanical Freedom Line Technical Data NEMA Contactors and Starters January 00 Sheet Table.-. dc Coil Data NEMA Sizes Motor Voltage 00 and 0 48 and and Change amature, magnet and amature interlock after x operations. General Coil Data Coil Offering tape wound: NEMA Sizes 00 0 UL Insulation Rating: Class (B) Coil Offering encapsulated: NEMA Sizes UL Insulation Rating: Class (A) Coil Offering encapsulated: NEMA Sizes 4 P.U. Sealed D.O. Volts Amperes Watts Volts (Hot) Amperes Watts (Hot) UL Insulation Rating: Class (F) Operational Limits: 8% to % of rated voltage ac 80% to % of rated voltage dc 80% 80% 80% 80% 8% 0% % % % % % % 7% 7% % 4% Table.-4. Coil Data Notes % 0% 0% 0% % 9% 8% 9% % % % % % % 8% % P.U. Time ms P.U. Pickup time is the average time taken from closing of the coil circuit to main contact touch. D.O. Dropout time is the average time taken from opening of the coil circuit to main contact separation. Cold Coil data with a cold coil. Hot Coil data with a hot coil. D.O. Time ms Maximum Operation Rate Operations/Hour,0,0,0,0,0,0,0,0,00,00,00,00 Mechanical Life Millions All data is based on a standard contactor with no auxiliary devices and a Vac or Vdc magnet coil. Coil data has a ±% range depending on the application, therefore specific data may vary. CA08E

8 January 00 Sheet Motor Starters & Contactors Low Voltage Motor Starters Electromechanical Freedom Line Technical Data NEMA.- Table.-. Specifications Sizes 00 Contactor Catalog Number/Size Configuration Number of Poles Auxiliary Contacts, Standard Add-on Auxiliary Contacts CNA NEMA Size 00,, 4 4th Pole NO () Top (4) or Side (4) CNB NEMA Size 0, Top (4) or Side () CND NEMA Size,, 4, Top (4) or Side () CNG NEMA Size,, 4, Top (4) or Side () CNK NEMA Size Frame Size 4 mm 4 mm mm mm 90 mm Maximum Voltage Rating Vac Vac Vac Vac Vac Continuous Ampere Ratings (I) 9 Amperes 8 Amperes 7 Amperes 4 Amperes 90 Amperes Maximum Horsepower (hp) -Phase V V / 7-/ 7-/ -Phase 00 V V V 7 V Coil Operating Range % of Rated Voltage Operating Temperature Maximum Operating Altitude in Feet (m) Mechanical Life Electrical Life (480 V/0 Hz) AC- AC-4 Wire Range Power Terminals Control Terminals Power Terminal Torque Line and Load lb-in Auxiliary Contact Rating -/ -/ 7-/ 7-/ -% to +% -% to +% -% to +% -% to +% -% to +% -0 to C,000 (88) 0,000,000 4,000,000 90,000 Stranded, 4 Solid Cu Stranded, 4 Solid Cu -0 to C,000 (88) 0,000,000,000,000 8,000 8 Stranded, 4 Solid Cu Stranded, 4 Solid Cu -0 to C,000 (88),000,000,000,000 00, Stranded or Solid Cu Stranded, 4 Solid Cu -0 to C,000 (88),000,000,00,000,000 4 (Upper) and/ or 4 (Lower) Stranded or Solid Cu Stranded, 4 Solid Cu 7 0 (4 8 AWG) 4 ( 4 AWG) 0 ( AWG) A, P0, Left Side (4) or Right Side () to C,000 (88),000,000,700,000 80,000 /0 4 Cu Stranded 4 Solid Cu (4 AWG) (8 AWG) 4 ( 4 AWG) 0 ( /0 AWG) CA08E

9 .- Motor Starters & Contactors Low Voltage Motor Starters Electromechanical Freedom Line Technical Data NEMA January 00 Sheet Table.-. Specifications Sizes 4 8 Contactor Catalog Number/Size Configuration Number of Poles Auxiliary Contacts, Standard Add-on Auxiliary Contacts CNN NEMA Size 4, Left Side () or Right Side (4) CNS NEMA Size, Left Side () or Right Side (4) CNT NEMA Size Top Left NO/NC () Top Right NO/NC () CNU NEMA Size 7 Top Left NO/NC () Top Right NO/NC () CNV NEMA Size 8 Side NO/NC () NO/NC () Frame Size 80 mm 80 mm 80 mm 80 mm 4 mm Maximum Voltage Rating Vac Vac Vac Vac Vac Continuous Ampere Ratings (I) Amperes 70 Amperes Amperes 8 Amperes Amperes Maximum Horsepower (hp) -Phase V V -Phase 00 V V V 7 V Coil Operating Range % of Rated Voltage Operating Temperature Maximum Operating Altitude in Feet (m) Mechanical Life Electrical Life (480 V/0 Hz) AC- AC-4 Wire Range Power Terminals Control Terminals % to +% -% to +% -% to +% -% to +% -% to +% -0 to C,000 (88),000, ,000 70,000 Open /0 8 Cu; Enclosed 0 kcmil Cu/Al Stranded, 4 Solid Cu -0 to C,000 (88),000,000 00,000 4, kcmil or () 0 kcmil /0 Cu/Al Stranded, 4 Solid Cu -0 to C,000 (88),000,000 90,000 7,0 () 70 kcmil /0 Cu/Al Stranded, 4 Solid Cu to C,000 (88),000,000,000,000 () 70 kcmil /0 Cu/Al Stranded, 4 Solid Cu to C,000 (88),000,000,000 4,00 (4) 70 kcmil /0 Cu/Al Stranded, 4 Solid Cu 4 Power Terminal Torque Line and Load lb-in Auxiliary Contact Rating A, P0 CA08E

10 January 00 Sheet Motor Starters & Contactors Low Voltage Motor Starters Electromechanical Freedom Line Technical Data NEMA.-7 Table Volts, 0 Hz Starters Maximum hp Ratings Table.-8. Motor FLA Current Ranges Size Lower Current Range for motor hp range /4 hp to hp at V. Table.-9. Maximum Horsepower Rating of Starters for 0 V, 0 Hz Application Table.-. Wire (7 C) Sizes AWG or kcmil NEMA Sizes 00 Open and Enclosed Two compartment box lug. NEMA Size 4 Maximum hp to. S.F. NEMA Size S.F Table.-. Power Terminals Load Cu Only (Stranded or Solid) Minimum per NEC. Maximum wire size: Sizes 00 and 0 to #8 and Sizes to # IEC Size A B C D E F G H J K L M N P R S hp NEMA Size Power Terminals Line 00 0 Heater Pack Catalog Numbers H00B H0B H0B H0B H0B, H04B H0A H07A H0B H0B H07B Cu Only # # Stranded, # #4 Solid #8 # Stranded, # #4 Solid #8 #4 Stranded or Solid # #4 (Upper) and/or # #4 (Lower) Stranded or Solid Minimum #4 # # #8 #4 # # #4 # Control Terminals Cu Only # # Stranded, # #4 Solid Heater Pack Catalog Numbers HB HB HB HB HB, H4B H4 H7 HB HB H7B Minimum #4 # # #8 #4 # # #4 # Table.-. Wire (7 C) Sizes AWG or kcmil NEMA Sizes 8 Open and Enclosed NEMA Size Wire Size Power Terminals Line and Load #/0 #4 Al Cu 4 Open #/0 #8 Cu Enclosed 0 kcmil # Al Cu 70 kcmil # or () 0 kcmil #/0 Al Cu () 70 kcmil #/0 Al Cu 7 () 70 kcmil #/0 Al Cu 8 (4) 70 kcmil #/0 Al Cu Control Terminals Cu Only # # Stranded, # #4 Solid CA08E

Enclosures. See Section Typical Description

Enclosures. See Section Typical Description January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic

More information

Product Selection 3-Pole Contactors

Product Selection 3-Pole Contactors - Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the

More information

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9 February 999 NEA Freedom Contactors and ers Catalog Number Selection - ECN A A F - Design N = Nema odification Codes (See Pages -6 to -) Class Page 0 - Contactors -4 0 - Reversing Contactors -8 05 - FVNR

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information

NEMA Vacuum Break Contactors and Starters

NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Starter.1 Product Description....................................... Application Description.................................... Operation...............................................

More information

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................

More information

2.1. NEMA Contactors and Starters

2.1. NEMA Contactors and Starters 3A Overload C306DN3B Contents Contactors Non-Reversing and Reversing...... Starters Three-Phase Non-Reversing and Reversing, Full Voltage.................... Starters Single-Phase Non-Reversing, Full Voltage,

More information

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents 1 January 00 Reduced Voltage Motor Starters Contents Description Page Open Type S7, Intelligent Technologies (IT.) Soft Starters Product Description............................................. Application

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control CEP7 Solid-State Overload Relay for Motor Control Centers and Technical Data Description Page Product Description.............................................. 2 Specifications...................................................

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control . 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................

More information

3.1. NEMA Manual Starters. Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters...

3.1. NEMA Manual Starters.   Contents Description Types B230, B330, Switches... MS Series, Single-Phase Starters... Product Description The B100 Manual Motor Starters can be used in single-phase applications rated hp at 240 Vac or 2 hp at 20 Vdc. The starter can also be rated for three-phase applications up to 10 hp

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 40A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview.............................................. 2 Application Description..........................................

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V 804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals: 3 ulletin 100 IEC Contactors ulletin 100 15 Sizes, 9 600 Guarded Terminals Dual Terminal Markings DC Control Option through 180 Wide Range of ccessories Top and Side Mounting uxiliary Contacts Timers Latches

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

SIGNAL WORDS QUALIFIED PERSON

SIGNAL WORDS QUALIFIED PERSON SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit

More information

Definite Purpose Contactors and Starters

Definite Purpose Contactors and Starters 0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in Canada Enclosed Full-Voltage Starters * ca.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters GE Energy Connections Made in USA Enclosed Full-Voltage Starters * www.geindustrial.com/products/starters GE Global Offer & Warranty starters utilize globally-rated IEC components which make it ideal for

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W

L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum . Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor circuit 5 =

More information

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller A pre-engineered solution with an integrated circuit breaker disconnect and an Altistart 22 soft start in a stand-alone enclosure Make the

More information

Contactors Low Voltage

Contactors Low Voltage 00Motor Starters and January 08 Sheet Motor Starters and ContactorsLow Voltage.0- ContactorsLow Voltage Contents Motor Starters and ContactorsLow Voltage Manual Motor Control MS Starter with Hand/Auto......................................-

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

MAGNETIC MOTOR STARTERS

MAGNETIC MOTOR STARTERS Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors

More information

For Options, Modifications and Accessories, see pages Discount Schedule A6

For Options, Modifications and Accessories, see pages Discount Schedule A6 Main and Feeder Units Bulletin 191F and 191M Outgoing Feeder Lug Compartment (FLUG) and Incoming Main Lug Compartment (MLUG)................................................. The Bulletin 191M and 191F

More information

Self-protected Combination Starters System PKZ 2-SP

Self-protected Combination Starters System PKZ 2-SP Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940

Well-Guard Control. Pumping Plant Panels. Catalog 8940CT9701R11/ Class 8940 Well-Guard Control Pumping Plant Panels Catalog 8940CT9701R11/15 2016 Class 8940 IRRIGATION OIL PRODUCTION CONTENTS Selection.............................................. Page 3 Factory Modifications.....................................

More information

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum

6.1. Pump Panels EC N B A A - Industrial Pump Panels. Catalog Number Selection. Pump Panel. Design N = Freedom 2 = A200 V = Vacuum .1 Catalog Number Selection Pump Panel Design N = Freedom 2 = A200 V = Vacuum Class 54 = Type 3R pump panel fusible disconnect 55 = Type 3R pump panel circuit breaker disconnect 4 = Part winding with motor

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Vacuum Contactors and Starters

Vacuum Contactors and Starters Vacuum s and Starters Size 4 Vacuum.1 Product Description....................................... Application Description.................................... Operation...............................................

More information

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes

Applications. Housings: copperfree (4/10 of 1%) aluminum Shaft, bushings and exposed hardware: stainless steel Standard Finishes AE Threaded Combination and Non-Combination Full Motor Starters Units Provide Disconnecting Means and Undervoltage, Circuit and Motor Running Protection. Class I, Division and, Groups C, D Class II, Division

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures Enclosures for hazardous areas clamped enclosures Clamped NEMA 7 classifi ed enclosures Clamped : NEMA 7 classified enclosures Safer. Faster. Easy access, lower risk and less downtime. Creative thinking

More information

BAC Custom Engineered Controls

BAC Custom Engineered Controls BAC Custom Engineered Controls Product Detail Product Introduction......................................... K2 BAC Custom Engineered Controls Benefits....................................................

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

4.1. Definite Purpose Contactors and Starters. Contents

4.1. Definite Purpose Contactors and Starters. Contents . Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,

More information

Industrial Control Power Transformers Class MT

Industrial Control Power Transformers Class MT Class MT Features Epoxy-encapsulated (50 5000); Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments

More information

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters .2 Type S80+, Soft Starters Contents Description Type S6, Solid-State Soft Starters........... Type S80+, Soft Starters Operation............................. Features.............................. Benefits...............................

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. usa.siemens.com/controls

More information

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

REVISIONS App PC. App Sud. App Thom TC 2014/03/25 /9 Rev Description Document format and number changed. Previous number 543-0.0.30 Rev n by TC 204/03/25 Sud TC 204/03/25 REVISIONS PC Thom VB LH Clyd r Act Issue Date YYYY/MM/DD Pending Pending Pending

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents. PART 1: GENERAL 1.01 This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is to apply the

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

Product Description. Application Description

Product Description. Application Description -2 Solid-State Controllers Type TL, Torque Limiter August 6 Contents Description Page Torque Limiters............ -2 Soft Start Controllers........ -4 Soft Start Controllers with Auxiliary Contact.....

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Contactors & Starters Index

Contactors & Starters Index ontactors & Starters Index NEMA ontrol Description Page Number General Information - HP... A Magnetic ontactors - HP...4 A Magnetic Reversing ontactors - HP... 4 A Magnetic Starters - HP... A Magnetic

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry See NEW preliminary information on Class 82 size 1 in an extra wide enclosure and size 2 standard enclosures. www.usa.siemens.com/controls

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Non-illuminated Push Buttons

Non-illuminated Push Buttons Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,

More information

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL

MECHANICAL AND ELECTRICAL COORDINATION SECTION MECHANICAL AND ELECTRICAL COORDINATION PART 1 - GENERAL 13686.00 MECHANICAL AND ELECTRICAL COORDINATION 230002-1 SECTION 230002 MECHANICAL AND ELECTRICAL COORDINATION 1.1 WORK INCLUDED PART 1 - GENERAL A. Work Included in This Section: Materials, equipment,

More information

Operation and Protection of Motors up to 600Hp at 460Vac (800A)

Operation and Protection of Motors up to 600Hp at 460Vac (800A) Operation and of Motors up to 600Hp at 460Vac (800) WEG enclosed starters series were designed to meet the requirements and flexibility frequently demanded in industrial applications. Featuring components

More information

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus Control and Expanded Functionality for Intelligent Technologies (IT.) See How IT. All Works Together A Complete Family of IEC

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

Reduced Voltage Motor Starters

Reduced Voltage Motor Starters Reduced Voltage Motor Starters Soft Start Controllers. Solid-State Controllers Product Overview........................................ Type S70, Soft Start Controllers............................. Type

More information

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches

Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches 2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information