1 Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to V UL Listed and CSA certifi ed for Group Motor Installations 12 Setting ranges from 0.1 to 16 amps. Up to 30kA or 0kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS32 Suitable for use with 3-phase motors up to 1 480V UL Listed and CSA certifi ed for Group Motor Installations 12 Setting ranges from 0.1 to 2 amps. Up to 0kA or 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS4x Suitable for use with 3-phase motors up to V UL Listed and CSA certifi ed for Group Motor Installations 14 Setting ranges from 11 to 0 amps Up to 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Type MS49x MS116 MS32 MS4X MS49X Suitable for use with 3-phase motors up to 7 480V UL Listed and CSA certifi ed for Group Motor Installations 22 Setting ranges from 11 to 100 amps Up to 100kA with no back up fuse required 3mm DIN rail snap-on mounting Wide range of accessories Single motor applications Single motor applications employing a manual motor protector (MMP) result in a simple, compact and economical alternative to conventional magnetic motor controllers for manual operation of a single motor. Upstream short circuit and overcurrent protection in the form of fuses or a circuit breaker is required but the MMP can replace the overload relay, contactor and associated electrical components and wiring for controlling the contactor. Group motor applications Group motor installations offer several advantages when controlling two or more motors or other loads over conventional single motor starters. Several MMPs can be grouped together and fed from a single set of fuses or a circuit breaker. These devices can be installed together on a single DIN rail and fed power through three phase insulated busbars and a power feed terminal. Protecting this group of MMPs is a single circuit breaker or fusible switch, sized specifi cally for the load. Excellent coordination and short circuit protection can be achieved, as high as 0kAIC, when using the MS32 product in this manner. Close coupling adapters are offered to connect contactors to the load side of each MMP for automatic operation of each motor. If a single motor experiences an overload, the associated MMP trips and allows the other motors to continue running. Numerous accessories are available for signaling in the event of a trip, to indicate status, to provide shunt trip and for undervoltage release. The main benefi ts of group installation are quick, fool proof assembly, minimal wiring and a reduction of the necessary enclosure size. The only constraint is that the upstream circuit protective device must be sized specifi cally for the load a highly desirable feature in order to provide the closest coordination and the greatest level of circuit protection. Article 430.3(C) of the NEC specifi es the requirements for group motor installations; all ABB MMPs meet these requirements. Low Voltage Products & Systems.1 ABB Inc Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH Fax:

2 Manual motor protectors General information Selection Group installation is an approach to building multi-motor control systems in accordance with Section of the National Electrical Code. The selection of components used in group installations is a simple process which consists of several steps. First is the selection of the appropriate fuse as Branch Circuit Protective Device (BCPD). Second is the selection of the appropriate motor starter and protector. Third, the selected MMP must be checked for UL listing with the selected BCPD and the available short circuit current at the application location. 1. Fused disconnect Calculate maximum fuse size according to NEC (c). I max (fuse size) = 17% x FLC (full load current for largest motor) + the sum of FLC (full load current for largest motor) + the sum of FLC values for other motors on that branch using NEC Table on the right. Select fuse from NEC Table below. Where I max falls between two fuse ampere ratings NEC (c) permits going to the next high ampere rating. 2. Motor protector selection Select the proper MMP catalog number for each motor load from the following pages based on the actual motor full load current (FLA) using the Thermal setting range column for reference. 3. MMP Interruption ratings Using the interruption ratings table on the next page, identify the system application voltage and interrupting capacity for the type of fuse selected in step 1 above. NEC Standard fuse amperes 1, 20, 2, 30, 40, 4, 0, 60, 70, 80, 90, 110, 12, 10, 17, 200, 22, 20, 300, 30, 400, 40, 00, 600, 700, 800, 1000, 1200, 1600 Examples: Select components for protecting the following 3-phase, 460VAC, squirrel cage induction motors. The nameplate data are: 1/2 HP, 1.0 FLA; 3 HP, 4.8 FLA; HP, 7.6 FLA; 7. HP, 11 FLA; 10 HP, 14 FLA. Example: using fused disconnect I max = 17% x 14 + ( ) = 48.9A Fuse rating using Table NEC = 0A Minimum disconnect size = 11% x Total FLA NEC table = 11% x ( ) = Disconnect for 0A fuses is ok. NEC Table full load current, 3ph AC motor Horsepower Induction type squirrel cage & wound rotor 1 230V 460V 7V amps amps amps 1/ / Note: Refer to NEC and NEC 430-3(d) for cable sizing. For full load currents of 208 and 200 volt motors, increase the corresponding 230 volt motor full-load current by 10% and 1%, respectively. MS32 data Motor rating at 460V Horsepower FLA, AC3 MS32 1/2 1.0 MS A9C MS A9C 7.6 MS A9C MS A12C MS32-16 A16C Contactor INCOMING LINES A B C ISOMAX MCCB or Fusible Switch (If specified) I> I> I> M I> I> I> M I> I> I> M I> I> I> M I> I> I> M L1 L2 L3 1C L1 L2 L3 2C L1 L2 L3 3C L1 L2 L3 4C L1 L2 L3 C T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 T1 T2 T3 MOTOR MOTOR MOTOR MOTOR MOTOR 1 These values of full-load current are for motors running at speeds usual for belted motors and motors with normal torque characteristics. Motors built for especially low speeds or high torques may require more running current, and multispeed motors will have full-load current varying with speed, in which case the nameplate current rating shall be used. The voltage listed are rated motor voltages. The currents listed shall be permitted for system voltage ranges of 110 to 120, 220 to 240, 440 to 480, and 0 to 600 volts..2 Low Voltage Products & Systems ABB Inc

3 Type MS116 Manual motor protectors MS116 Manual motor protectors Thermal setting Single-phase 3-phase Catalog List range (Amps) horsepower ratings 1 horsepower ratings number price 120V 240V 240V 480V 600V MS MS MS $ MS MS /2 1/2 MS /10 3/4 3/4 MS /6 1/ MS /8 1/ MS /4 1/ MS / MS / MS MS UL File # E Single phase motor ratings are based upon wiring all three poles in series. Low Voltage Products & Systems Discount schedule MA.3 ABB Inc

4 Manual motor protectors Type MS116 Accessories Auxiliary contact blocks for Type MS116 (side mount) Contact Catalog List confi guration number price 1 NO & 1 NC HK NO HK1-20 $ 33 2 NC HK1-02 Auxiliary contact blocks for Type MS116 (front mount) Contact Catalog List confi guration number price 1 NO & 1 NC HKF1-11 $ 33 HK1-11 HKF1-11 Bell alarm contact blocks for Type MS116 Contact Catalog List confi guration number price Undervoltage trip for Type MS116 1 NO & 1 NC SK NO SK1-20 $ 33 2 NC SK1-02 Voltage (VAC) Catalog number List price 24 UA UA UA UA1-120 $ UA UA UA1-41 SK1-11 UA1-120 Undervoltage trip with 1NO & 1NC auxiliary contact for Type MS116 Voltage (VAC) Catalog number List price 24 UA1-HK UA1-HK UA1-HK UA1-HK-120 $ UA1-HK UA1-HK UA1-HK-41 Locking device for Type MS116 Description Catalog number Adaptor for padlock Type SA1 MS32-SA1 $ 1 Complete padlock locking kit (adaptor, padlock & 3 keys) MS32-SA List price OTPA116 Molded plastic enclosures for Type MS116 Item Protection Catalog List description level number price Gray enclosure with black handle IP64 OTPA116L2P1 $ 7 Yellow enclosure with red handle IP64 OTPA116A2P1 7 Gray enclosure with clear cover, 4 module IP Gray enclosure with clear cover, 6 module IP Plastic adaptors for enclosures for Type MS116 Catalog List Description number price PG16 to 1/2NPT PG16-1/2NPT $ Shunt trip for Type MS116 Voltage Catalog List (VAC) number price 24V AA V AA V AA V AA1-400 $ 7.4 Discount schedule MA Manual motor protectors Low Voltage Products & Systems Discount schedule H6 Handles, shafts & accessories ABB Inc

5 Type MS116 Accessories Manual motor protectors OHB2AJ Door mounting hardware for for Type MS116 1 Description Power feed terminal blocks for Type MS116 Description for 4 AWG wire for busbar S1-M1 S1-M2 Catalog number Catalog number List price Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 Black selector handle OHB2AJ 30 NEMA 1, 3R, 12 Red, yellow selector handle OHY2AJ length shaft OXSX length shaft OXSX180 6 List price $ 24 S1-M1 PS1-2-1 S1-M2 Busbars for Type MS116 Description Catalog number List price for 2 devices without auxiliary contacts PS1-2-0 $ 24 for 3 devices without auxiliary contacts PS for 4 devices without auxiliary contacts PS for devices without auxiliary contacts PS for 2 devices with 1 auxiliary contact PS for 3 devices with 1 auxiliary contact PS for 4 devices with 1 auxiliary contact PS for devices with 1 auxiliary contact PS for 2 devices with 2 auxiliary contacts PS for 3 devices with 2 auxiliary contacts PS for 4 devices with 2 auxiliary contacts PS for devices with 2 auxiliary contacts PS Busbar for direct mounting of contactors Description Catalog number List price B6/B7 BEA7/116 $ 12 A9/A12/A16 BEA16/ A26 BEA26/116 1 S1- M2 PS1-4-1 S1- M2 PS1-... PS1-... SK1-... HK1-... SA1 UA1-... HKF1-11 HK1-... HK Must have shaft coupler, handle and shaft for through-the-door operation. Low Voltage Products & Systems Discount schedule MA Manual motor protectors. ABB Inc Discount schedule H6 Handles, shafts & accessories

6 Manual motor protectors Type MS116 Technical data Softstarter type MS116 Standards, approvals UL, CSA, CE Rated operating current A 16 Current range A Number of poles 3 Frequency Hz 0 / 60 Tripping class A 10 Max. kaic & 600V kaic 30 Mechanical life Operations 100,000 Wire range AWG Terminal torque in. lbs. 14 Terminal tool options Flat screwdriver PZ2 Permissible attitude without derating m 3000 Degree of protection IP20 UL Listed for group installation Yes Self-protected Type E manual combination starter No Accessories Terminal shroud No Auxiliary contacts Yes Shunt trip No Trip signal contacts Yes UV release Yes Busbar Yes Through the door handle Yes Minimum enclosure size H x W x D Loads for accessories Auxiliary contact for front mounting, HKF AC1 24 V, 3.0 A 230 V, 1. A Auxiliary contact for front mounting, HKF DC13 24 V, 1.0 A 48 / 60V, 0.7 A 110 V, 0.27 A Auxiliary and signal contact, HK + SK AC1 24 V, 6 A 230 V, 4 A 400 V, 3 A Auxiliary and signal contact, HK + SK DC13 24 V, 2 A 110 V, 0. A 220 V, 0.2 A 440 V, 0.1 A Electromagnet trips Response value set ex-works x In Undervoltage release Pick-up value % of U C 8 Drop-out value % of U C 3 7 Power consumption Pick-up VA Consult factory Hold VA Consult factory Short-circuit protection MS 116 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I cc >I cs at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cu I cs gl, gg I cu I cs gl, gg I cu I cs gl, gg I cu I cs gl, gg I cu I cs gl, gg A A ka ka A ka ka A ka ka A ka ka A ka ka A Setting ranges to Short-circuit proof up to I cc =0kA Short-circuit proof up to I cc =30kA Low Voltage Products & Systems ABB Inc

7 Type MS116 Technical data Manual motor protectors General purpose MS116 range Maximum current (600 VAC Max.) Short circuit ratings 18,000 RMS symmetrical 480 VAC,000 RMS symmetrical 600 VAC Maximum ratings Horsepower, HP, Breaking-All-Lines MS116 Single phase Three phase Range 0/60 Hz 0/60 Hz 120 VAC 240 VAC 240 VAC 480 VAC 600 VAC /2 1/ /10 3/4 3/ /6 1/ / /8 1/ /4 1/2 1 1/ /2 1 1/ / / / Low Voltage Products & Systems.7 ABB Inc

8 Manual motor protectors Type MS116 Approximate dimensions MS116 MS116 mounted with A9 - A16 contactor MS116 mounted with B6/B7 minicontactor 4 8, HKF HKF1-11 BEA16/116 BEA7/116 A9... A16 B6 / B MS116 mounted with UA1..., SK!..., HK1..., HKF UA1-... SK1-... HK HKF Low Voltage Products & Systems ABB Inc

9 Type MS116 Approximate dimensions Manual motor protectors Molded plastic enclosures for MS116 OTPA116L2P1 and OTPA116A2P Low Voltage Products & Systems.9 ABB Inc

10 Manual motor protectors Type MS32 MS Manual motor protectors Type MS32 Thermal setting Single-phase 3-phase Catalog List range horsepower ratings 1 horsepower ratings number price (Amps) 120V 240V 240V 480V 600V MS MS $ MS MS /2 1/2 MS /10 3/4 3/4 MS /6 1/ MS /8 1/ MS /4 1/ MS / MS / MS MS MS MS MS32 UL File #E Accessories UL File #E9033 ➀ Single phase motor ratings are based upon wiring all three poles in series..10 Discount schedule MA Low Voltage Products & Systems ABB Inc

11 Type MS32 Accessories Manual motor protectors MS32-HK11 Auxiliary contact blocks for Type MS32 (side mount) Auxiliary contact blocks for Type MS32 (front mount) Bell alarm contact blocks for Type MS32 1 NO & 1 NC MS32-HK11 2 NO MS32-HK20 $ 33 2 NC MS32-HK02 1 NO & 1 NC MS32-HKF11 2 NO MS32-HKF20 1 NO MS32-SK10 1 NC MS32-SK01 $ 33 $ 33 MS32-HKF11 Shunt trips for Type MS VAC/VDC, 60 Hz MS32-ST VAC/DC, 60 Hz MS32-ST24 $ 82.0 MS32-UA24 Undervoltage trip for Type MS32 24V MS32-UA24 48V MS32-UA48 60V MS32-UA60 110V MS32-UA110 $ V MS32-UA V MS32-UA400 41V MS32-UA41 480V MS32-UA480 Remote control unit MS32-AS Electrically operated remote control unit for MS32. For use up to MS32-16 and below. Not for use with MS32-20 & MS32-2. Provided with 1 NO & 1 NC auxiliary contacts and 1NO trip signal contacts NOTE: May not be used with HFK, SK, ST or UV accessories 24V AC/DC RC32-24V 48V AC/DC RC32-48V 60V AC/DC RC32-60V $ V AC/DC RC32-110V 230V AC/DC RC32-230V MS32-SA1 MS32-SA3 Supporting terminal for Type MS32 for UA or as N/LS clamp MS32-AS $ 1 Padlocking devices for Type MS32 Adapter for padlock type SA1 MS32-SA1 $ 1 Complete padlock kit (includes adaptor, padlock & 3 keys) MS32-SA Low Voltage Products & Systems Discount schedule MA.11 ABB Inc

12 Manual motor protectors Type MS32 Accessories Switch cublicle mounting kit Molded plastic enclosures for Type MS32 Item Protection Catalog List description level number price Light gray enclosure with black handle IP64 OTPA32B2P1 $ 7 Light gray enclosure with red/yellow handle IP64 OTPA32A2P1 7 Gray enclosure w/clear lid, 4 module IP Gray enclosure w/clear lid, 6 module IP NOTE: Use Discount schedule MA for IP64 enclosures ; use Discount schedule CB8 for IP enclosures. Plastic adaptors for enclosures for Type MS32 PG16 TO 1/2 NPT PG16-1/2 NPT $ 10 MS32-BB1 Selector handles for through-the-door operation for Type MS32 1 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 black selector handle OHB2AJ 30 NEMA 1, 3R, 12 red/yellow selector handle OHY2AJ length shaft OXSX length shaft OXSX180 6 NOTE: Use Discount schedule MA for shaft coupler; use Discount schedule H6 for handles and shafts. Power feed terminal blocks for Type MS32 Standard, accepts 4 AWG wire MS32-SM1 $ 24 Low profi le, accepts 4 AWG wire MS32-BB1 2.0 MS32-SM1 PS3-2-0 PS3-4-0 Busbars for Type MS32 2 for 2 devices; without auxiliary switch PS3-2-0 $ 24 for 3 devices; without auxiliary switch PS for 4 devices; without auxiliary switch PS for devices; without auxiliary switch PS for 2 devices; with 1 auxiliary switch PS for 3 devices; with 1 auxiliary switch PS for 4 devices; with 1 auxiliary switch PS for devices; with 1 auxiliary switch PS for 2 devices; with 2 auxiliary switches PS for 4 devices, with 2 auxiliary switches PS Busbars can be daisy chained to connect additional MS32s. Close coupling adapters Device Catalog number List price MS32 + B6/B7 contactor BEA7/32 MS32 + VB6/VB7 reversing contactor MS32-VB7 $ 12 MS32 + A9, A12, A16 contactor BEA16/ MS32 + A26 contactor BEA26/32 1 MS32 coupled to mini-contactor 1 Must have shaft coupler, handle and shaft for through-the-door operation. 2 UL fi le # E16720; CSA fi le# LR98427M Discount schedule MA Manual motor protectors & accessories Discount schedule H6 Handles, shafts & accessories Low Voltage Products & Systems Discount schedule CB8 IP plastic enclosures ABB Inc

13 Type MS32 Accessories DLA starters, non-reversing Manual motor protectors + = MS DLA DLA starter Manual motor protectors MS32 Single-phase 3-phase Thermal setting horsepower ratings 1 horsepower ratings Catalog List DLA module List range (amps) number price catalog number price 120V 240V 240V 480V 600V MS MS MS $ MS /2 1/2 MS DLA $ /10 3/4 3/4 MS /6 1/ MS /8 1/ MS /4 1/ MS / MS DLA / MS DLA MS32-16 DLA MS DLA MS DLA General information The construction of DLA starters is based on ABB A-Line contactors. The mounting plate, including a built-in A contactor, is designed to integrate an ABB manual motor starter type MS32. Starters can be easily made with protection against overloads and short-circuits (Type I or Type II coordination). The technical characteristics of these devices are identical to A-Line contactors. The advantages are as follows: Simplifi ed installation: DLA starters mount onto 3 x 1 mm DIN rail (EN 0022). Direct mounting of manual motor starter MS32 Contactor coil terminals accessible on lower side. High performance as a result of this combination of the MS32 manual motor starter with high breaking capacitiy and the new A-Line contactor ensuring high electrical durability. Accessory types on the manual motor starter: Set of bus bars, external operating mechanism, padlock holder, auxiliary contact, undervoltage coil, shunt trip, etc. Coil voltage selection All AC operated catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the Coil voltage selection chart for the two digits after the last dash in the catalog number. AC coils only. Ex.: A 240V coil is required for a DLA9 starter: DLA Ordering instructions The MS32 manual motor starters and the DLA module must be ordered separately and assembled by customer. Accessories for DLA starters Accessories for DLA starters are the same as for the individual contactors and manual motor protectors. Coil voltage selection chart Volts Hz For other AC voltages, see page Single phase motor ratings are based upon wiring all three poles in series. 2 In group motor applications, use the lowest maximum fuse or MCCB size. Low Voltage Products & Systems Discount schedule MA MS32.13 ABB Inc Discount schedule AA DLA

14 Manual motor protectors Type MS32 Accessories WLA starters, reversing + = MS WLA WLA... Manual motor protectors Single-phase 3-phase Thermal setting horsepower ratings 1 horsepower ratings Catalog List Reversing DLA List range (amps) number price module catalog price 120V 240V 240V 480V 600V number MS MS MS MS $ MS /2 1/2 MS WLA $ /10 3/4 3/4 MS /6 1/ MS /8 1/ MS /4 1/ MS / MS WLA / MS WLA MS32-16 WLA MS WLA MS WLA Coil voltage selection All AC operated catalog numbers include a 120VAC coil. To select other coil voltages, substitute the code from the Coil voltage selection chart for the two digits after the last dash in the catalog number. AC coils only. Ex.: A 240V coil is required for a DLA9 starter: DLA Ordering instructions The MS32 manual motor starters and the DLA module must be ordered separately and assembled by customer. Accessories for DLA starters Accessories for DLA starters are the same as for the individual contactors and manual motor protectors. Coil voltage selection chart Volts Hz For other AC voltages, see page Single phase motor ratings are based upon wiring all three poles in series. 2 In group motor applications, use the lowest maximum fuse or MCCB size..14 Discount schedule MA MS32 Low Voltage Products & Systems Discount schedule AA WLA ABB Inc

15 Type MS40 MS497 Manual motor protectors MS40 MS497 Manual motor starters FLA adjustment range Horsepower ratings Single-phase1 Three-phase 11V 230V 200V 208V 230V 460V 7V Weight Availability Catalog List (lbs) code number price MS A MS40-16 $ A MS A MS A MS A MS A MS A MS MS A MS A MS A MS A MS A MS A MS MS B MS B MS B MS B MS B MS B MS B MS B MS B MS B MS MS B MS B MS B MS B MS B MS B MS B MS MS B MS B MS B MS B MS B MS B MS Availability code A Standard item, stock to two weeks lead time B Stock to four weeks lead time C 4 to 6 weeks lead time UL File # E16720 Overload tripping class 10 Overload tripping class 20 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Maximum motor current 9A. Low Voltage Products & Systems Discount schedule MA.1 ABB Inc

16 Manual motor protectors Type MS40 MS497 for UL 08 Type E Applications MS40-16E MS497-16E Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Horsepower ratings Single-phase1 Three-phase 11V 230V 200V 208V 230V 460V 7V Weight Availability Catalog 3 List (lbs) code number price MS A MS40-16E $ A MS40-20E A MS40-2E A MS40-32E A MS40-40E A MS40-4E A MS40-0E 8 MS A MS49-40E A MS49-0E A MS49-63E A MS49-7E A MS49-90E A MS49-100E 810 MS B MS497-16E B MS497-20E B MS497-2E B MS497-32E B MS497-40E B MS497-0E B MS497-63E B MS497-7E B MS497-90E B MS E 810 MS B MS41-16E B MS41-20E B MS41-2E B MS41-32E B MS41-40E B MS41-4E B MS41-0E 8 MS B MS496-40E B MS496-0E B MS496-63E B MS496-7E B MS496-90E B MS E 810 Availability code A Standard item, stock to two weeks lead time B Stock to four weeks lead time C 4 to 6 weeks lead time 1 Single phase motor ratings are based upon wiring all three poles in series. 2 Maximum motor current 9A. 3 Catalog number includes all parts required for UL08/E applications..16 Discount schedule MA Low Voltage Products & Systems ABB Inc

17 Accessories Type MS40 MS497 Manual motor protectors HK4-11 Auxiliary contacts top mount Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price 1 N.O. + 1 N.C A HK changeover B HK-W Auxiliary contacts mounts on left side, max. 1 Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price 1 N.O. + 1 N.C A HKS N.O B HKS4-20 $ 36 2 N.C B HKS4-02 Auxiliary release Only one auxiliary release per manual motor protector Mounts on right side of manual motor protector $ 36 HKS4-02 UA4-HK-220 AA4-24 Item Rating Weight Pkg. Avail. Catalog List description (lbs) qty. code number price V, 0 60Hz A UA V, 60Hz A UA4-208 Undervoltage release V, 0 60Hz A UA4-240 $ V, 0Hz B UA V, 60Hz A UA4-480 Undervoltage release 230V, 0Hz B UA4-HK-230 with early make contacts 400V, 0Hz B UA4-HK N.O. 480V, 60Hz A UA4-HK-480 Voltage Voltage continuous sec. max. 0 60Hz 0 60Hz, DC Shunt trip Power feed terminal blocks for MS4X Busbars for MS4X Close coupling adapters V B AA V A AA V B AA V B AA4-41 For feeding power to multiple MS4Xs when using busbar Accepts 10-1/0 AWG, 108A 93 S4-M1 $ 81 PS4-2-0 $ 1 Without side mounted auxiliary devices PS PS PS With one side mounted auxiliary device PS PS MS4X + A30, A40 BEA40/40 $ 4 MS4X + A0 BEA0/40 63 MS49X + A0, A63, A7 BEA7/ MS49 + A9, A110 BEA110/ Mounting sequence: motor protection switch, pilot switch, auxiliary switch. Low Voltage Products & Systems Discount schedule MA.17 ABB Inc

18 Manual motor protectors Accessories Type MS40 MS497 Terminal shrouds Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price for MS4x A KA40 1 $ 1 for MX49x A KA for MS49x A KA49C 2 21 FLA adjustment cover Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price for MS4x A SA40 3 $ 30 KA40 MS49x Type E Terminal Required for UL 08 Type E Applications Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price for MS49x.0 1 B DX49 $ 4 Signalling contact indication of short-circuit trip (required for UL08 Type E applications) Item Weight Packaged Availability Catalog List description (lbs) in quantity of code number price Short circuit trip 1 N.O. + 1 N.C A SK4-11 $ 60 SA40 Selector handles for thru the door operation for Types MS40 & MS41 4 Shaft coupler MSMN $ 1 NEMA 1, 3R, 12 black selector handle OHB2AJ 30 NEMA 1, 3R, 12 red/yellow selector handle OHY2AJ length shaft OXSX length shaft OXSX180 6 DX49 SK Plug onto box terminals in each case. 2 Plug onto housing after removing box terminals, if using cable lugs or buses. 3 Supplied only as a set of 10 scale covers. 4 Must have shaft coupler, handle and shaft for through-the-door operation..18 Discount schedule MA Manual motor protectors Low Voltage Products & Systems Discount schedule H6 Handles, shafts & accessories ABB Inc

19 Short circuit ratings MS32 Technical data Type MS32 Short circuit ratings Short Circuit Maximum Fuse Range rating size ka, 600VAC A Manual motor protectors Group installation short circuit ratings MS32 ka 30 ka 0 ka 8kA Current Fuse MCCB Fuse MCCB Fuse MCCB Fuse range A A A A 480V S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S4H S7H S7H S4H S7H S7H S4H S7H S7H S4H20 600V S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S7H S4H S7H S7H S7H S7H S7H S4H S7H S4H20 1 Fuse: Rated 1600A, Listed Class L. All others, listed RK. Both time delay fuses. 2 Fuse: Rated 1600A, Listed Class L. All others, listed K. Both time delay fuses. Low Voltage Products & Systems.19 ABB Inc

20 Manual motor protectors Technical data Short circuit protection Type MS32 Short-circuit protection MS32 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I cc >I cs at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cs gl, am I cs gl, am I cs gl, am I cs gl, am I cs gl, am ka A ka A ka A ka A ka A A A Fuse types: Diazed, l.v.h.b.c., utilisation categories: gl, am (VDE), gl/gg (IEC) Setting ranges to Short-circuit proof No back-up fuse required up to I cc = 100 ka / Short-circuit protection MS32 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I cc >I cs at at at at at from to 230 V AC 400 V AC 440 V AC 00 V AC 690 VAC I cs gl, am I cs gl, am I cs gl, am I cs gl, am I cs gl, am ka A ka A ka A ka A ka A A A Fuse types: Diazed, l.v.h.b.c., utilisation categories: gl, am (VDE), gl/gg (IEC) Setting ranges to Short-circuit proof No back-up fuse required up to I cc =0kA / I cs = Rated service short-circuit breaking capacity, I cu = Rated ultimate short-circuit capacity, I cc = Prospective short-circuit current at installation location. I cs = I cu in the case of MS 32 and MS 116!.20 Low Voltage Products & Systems ABB Inc

21 Technical data Type MS32, MS4x, MS49x Manual motor protectors Device type MS32 MS40 MS41 MS49 MS496 MS497 Standards, approvals UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE UL, CSA, CE Rated operating current A Current range A Number of poles Frequency Hz 0/60 0/60 0/60 0/60 0/60 0/60 Tripping class A Max. kaic & 600V kaic Mechanical life Operations 100,000 0,000 0,000 0,000 0,000 0,000 Wire range AWG x18-3x18-2 2x18-3x18.2 2x10-1/0; 1x10-2/0 2x10-1/0;1x10-2/0 2x10-1/0; 1x10-2/0 Terminal torque in. lbs Terminal tool options fl at screwdriver fl at screwdriver fl at screwdriver hex allen hex allen hex allen PZ2 PZ2 PZ2 4mm 4mm 4mm Permissible altitude without derating m Degree of protection IP20 IP20 IP20 IP20 IP20 IP20 UL Listed for group installation Yes Yes Yes Yes Yes Yes Self-protected Type E manual combination starter No Yes Yes Yes Yes Yes Accessories Terminal shroud No Yes Yes Yes Yes Yes Auxiliary contacts Yes Yes Yes Yes Yes Yes Shunt trip Yes Yes Yes Yes Yes Yes Trip signal contacts Yes Yes Yes Yes Yes Yes UV release Yes Yes Yes Yes Yes Yes Busbar Yes Yes Yes No No No Through door handle Yes Yes Yes No No No Low Voltage Products & Systems.21 ABB Inc

22 Manual motor protectors Technical data Type MS32, MS4x, MS49x Manual motor starter type MS32 MS40/41 MS49/496/497 Auxiliary circuits Load rating of the auxiliary circuits Minimum load at: 24 VDC ma ma at 17 VDC 12 VDC ma 10 Rated operating at AC 1 to 24 VAC A 2. current I e 230 VAC A 2 3 / 0. / VAC A 1 1. / / 3 12 Rated operating at DC 13 to 24 VDC A 2. / / current I e 60 VDC A 2. / 0.1 / 110 VDC A / / VDC A / / VDC A / 0.1 Short circuit protection back up fuse gl A 10 gl / gg 10 A am A 6 Release Device for phase failure protection With With Electromagnetic trips Response value set ex-works I n I n 1.6 I n 9 14 I n I n I n 4 Undervoltage release Pick-up value % of U c 8 8 Drop-out value % of U c Power consumption - Pick-up VA Power consumption - Hold VA Open circuit shunt release Pick-up value % of U c 8 70 Relative duty consumption % ED 100 at voltages 0 / 60 Hz to Power Pick-up VA V: Consult factory Hold VA Consult factory 1 Correction factors for other frequencies on request. 2 On front side 1 chageover contact / on front side 1 NO + 1 NC / at side, 1 NO + 1 NC, 2 NO, 2 NC V: vA.22 Low Voltage Products & Systems ABB Inc

23 Technical data Short circuit protection Type MS40/41, MS49,6,7 Manual motor protectors Short-circuit protection MS40 / MS41 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I cu >I cu Setting ranges 230 V AC 400 V AC 440 V AC 00 V AC 690 V AC I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A Short-circuit-proof No back-up fuse required up to I cc = 100kA Short-circuit protection MS49 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I cu >I cu Setting ranges 230 V AC 400 V AC 440 V AC 00 V AC 690 V AC I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A Short-circuit-proof No back-up fuse required up to I cc = 100kA Short-circuit protection MS496 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I cu >I cu Setting ranges 230 V AC 400 V AC 440 V AC 00 V AC 690 V AC I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A Short-circuit-proof No back-up fuse required up to I cc = 100kA Short-circuit protection MS497 Setting ranges, short-circuit strength and max. back-up fuses Maximum rated current of the short-circuit fuses if I >I cu cu Setting ranges 230 V AC 400 V AC 440 V AC 00 V AC 690 V AC I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg I cs I cu gl,gg in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A in ka in ka in A Short-circuit-proof No back-up fuse required up to I cc = 100kA I cs = Rated service short-circuit breaking capacity, I cu = Rated ultimate short-circuit breaking capacity I cc = pprospective short-circuit current at installation location. Low Voltage Products & Systems.23 ABB Inc

24 Manual motor protectors Technical data IEC coordination tables Coordination tables The tables below show the MS 32 manual motor starter and DLA starter combinations according to the type of coordination and motor current. Motor power AC-3 MS 32 manual motor starter DLA starter WLA starter Copper Max. and rated current type type cable authorized three-phase cage motor, Type Setting (120V coil shown) (120V coil shown) current for 100 rpm range Minimum combination 380 V cross- 400 V section kw A A A mm2 A Coordination type I, 400 V 0 Hz, 0 ka, normal starting MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA * Ambient temperature 30 C Coordination type II, 400 V 0 Hz, 2 ka, normal starting MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA MS DLA WLA * Ambient temperature 30 C.24 Low Voltage Products & Systems ABB Inc

25 Approximate dimensions MS32 Manual motor protectors Inches [Millimeters] MS HK, SK, AS RC32 MS32 Power feed terminal blocks for MS Connection terminal block for busbar Connection terminal block for 4 AWG / 2 mm wires Low Voltage Products & Systems.2 ABB Inc

26 Manual motor protectors Approximate dimensions Accessories for MS Inches [Millimeters] Busbar connectors for MS Busbar Connector (2 x MS 32 with 1 aux.contact) Busbar Connector (4 x MS 32 with aux.contact) Molded plastic enclosures for MS32 OTPA32B2P1 and OTPA32A2P Low Voltage Products & Systems ABB Inc

27 Inches [Millimeters] Approximate dimensions Accessories for MS32 DLA9 DLA26 Manual motor protectors DLA9 DLA DLA Ø for M DLA DLA Ø for M Low Voltage Products & Systems.27 ABB Inc

28 Manual motor protectors Approximate dimensions MS40 & MS Inches [Millimeters] MS C.L. MS C.L..28 Low Voltage Products & Systems ABB Inc

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

Type MS450 MS497. Phone: Fax: Web:  -   Manual motor protectors Manual motor protectors Type MS40 MS497 MS40 MS497 Manual motor starters Overload tripping class 10 Overload tripping class 20 FLA adjustment range Single-phase1 Horsepower ratings Three-phase 11V 230V

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

smissline Description

smissline Description Modular power distribution bus system Description The power distribution bus system provides a versatile and flexible means of distributing power to a wide variety of electrical devices. Ideal for group

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - HK1-11 HKF1-11 HK-11 HKS-20 uxiliary contacts Mounting uxiliary contacts position Pilot duty rating Instantaneous Lagging / leading / max. 116 132 5x 9x quantity ac dc NO NC NO NC 2 - - - HK1-20 Right

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

System pro M compact Miniature Circuit Br eakers Description Features

System pro M compact Miniature Circuit Br eakers Description Features System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding

More information

Technical Catalogue. Manual Motor Starters MS 116, MS 325, MS 4xx

Technical Catalogue. Manual Motor Starters MS 116, MS 325, MS 4xx Technical Catalogue Manual Motor Starters MS 116, MS 325, MS 4xx 37 Manual motor starters Type Series M up to 45 kw (400 V AC) Contents Manual Motor Starter MS 116 0-16 A, 16/50 ka... 6 Manual Motor Starter

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

Manual Motor Starter MS 116. Technical Catalogue

Manual Motor Starter MS 116. Technical Catalogue Manual Motor Starter MS 116 Technical Catalogue The task: Economic fuseless motor protection Know-how in safe-keeping ABB is a renowned manufacturer of electrical motors. But apart from the hardware in

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

Technical Catalogue Manual Motor Starters. MS 116, MS 325, MS 4xx

Technical Catalogue Manual Motor Starters. MS 116, MS 325, MS 4xx Technical Catalogue Manual Motor Starters MS 116, MS 325, MS 4xx Manual motor starters Type Series M up to 45 kw (400 V AC) Contents Manual Motor Starter MS 116 0-16 A, 10/30 ka... 6 Manual Motor Starter

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

System pro M compact Modular DIN rail components E220 - E270 Series

System pro M compact Modular DIN rail components E220 - E270 Series Modular DIN rail components E0 - E0 Series Description Safe connection by box terminals Captive screws with Pozidrive slotted head, Pozidrive system, Gr. Snap-on labels available Quick mounting with snap-on

More information

Technical Catalogue. Manual Motor Starters MS116, MS325, MS4xx ABB

Technical Catalogue. Manual Motor Starters MS116, MS325, MS4xx ABB Technical Catalogue Manual Motor Starters MS116, MS325, MS4xx ABB 2 ABB Manual Motor Starters Type Series M up to 45 kw (400 V AC) Contents Manual Motor Starter MS116 0-16 A, 16/50 ka... 6 Manual Motor

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON Pilot Devices Technical data UL General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description Miniature Circuit Breakers S260, S270, S280, S290 Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized under standard

More information

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Softstarters. Softstarters Type SSM Medium voltage ,800V 1 Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Softstarters. Softstarters Power electronic brakes Type PEB

Softstarters. Softstarters Power electronic brakes Type PEB Softstarters Power electronic brakes Softstarters Description Electronic braking stops the load by injecting a controlled amount of DC current into a three phase AC motor. The Power Electronic Brake (PEB)

More information

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size Technical data UL Pilot Devices General UL technical data Contact blocks Rated insulation voltage, UL 600V Rated thermal current 10A / 600VAC 2.5A / 600VDC Minimum rating 24VDC, 5mA Mechanical life (millions

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices UL 077 Series Supplementary protective devices The UL 077 Series miniature supplementary protector offers a compact solution for protection requirements. The devices are DIN rail mounted. The is available

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays US Catalog January 2017 Motor protection and control Manual motor starters, contactors and overload relays Motor rated operational powers and currents The currents given below concern standard three-phase

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Short form catalogue Motor protection and control Manual motor starters

Short form catalogue Motor protection and control Manual motor starters Short form catalogue Motor protection and control Manual motor starters Motor protection and control Index Contents Beneifits 4 Features 5 Overview 6 Manual motor starter MS116 and MS132 8 Manual motor

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws A9 - AF1650 11 Contactors A9 - A110 Maximum UL/CSA horsepower ratings according to UL508 and CSA22.2 No. 14 Includes NEMA sizes 00-3 CE mark Compact space saving design Standard auxiliary contact configurations:

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

Product Specification Sheet #3LD2.1

Product Specification Sheet #3LD2.1 Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping

More information

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features

MCBs S260 S290. Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description. Features Miniature Circuit Breakers S260, S270, S280, S290 S260 S290 MCBs Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized

More information

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection Reduced voltage starters Open & enclosed Reduced voltage starters Description Compact, space saving design 8 starter frame sizes, A16 to A750 Maximum U.L. horsepower ratings Mechanically interlocking as

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking Contactor,4kW/400V,DCoperated Partno. DILEM-10-G(24VDC) Articleno. 010213 Program Product range Contactors Subrange DILEM contactors Application Mini Contactors for Motors and Resistive Loads Description

More information

A302DN.40/.63A Thermal Current Motor Starter

A302DN.40/.63A Thermal Current Motor Starter 4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

Individual & fixed bank capacitors

Individual & fixed bank capacitors Individual & fixed bank capacitors L O W V O L T A G E N E T W O R K Q U A L I T Y Description High reliability Well proven features of ABB dry type power factor cor rection capacitor tech nology are incorporated

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V 804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Miniature Circuit Breaker UL / CSA Range

Miniature Circuit Breaker UL / CSA Range PRODUCT CATALOG CANADA Miniature Circuit Breaker UL / CSA Range UL489 / CSA C22.2 No.5 devices UL1077 / CSA C22.2 No. 235 devices Electronic Protection Devices Technical data Miniature Circuit Breakers

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused

More information

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features S200 UL 489 Series Miniature S200 UL 489 Series Miniature Circuit Breakers Description The S200 Series miniature circuit breaker offers a compact solution for protection requirements. The S200U AND S200UP

More information

Softstarters Type PSS. Softstarters. General information

Softstarters Type PSS. Softstarters. General information General information The PSS Softstarter line brings a wide array of benefits for smaller motors in a flexible, compact form. The PSS "Flexible" Softstarter line PSS18/30 to PSS300/515 softstarters provide

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Compact Circuit Protector

Compact Circuit Protector Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

US CATALOG. Miniature Circuit Breakers

US CATALOG. Miniature Circuit Breakers US CATALOG Miniature Circuit Breakers Miniature circuit breakers Table of contents S(U)200 series miniature circuit breakers UL 489 series Description and features 2 SU200M-C 3 SU200M-K 4 SU200M-Z 5 SU200MR-K

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

Self-protected Combination Starters System PKZ 2-SP

Self-protected Combination Starters System PKZ 2-SP Self-protected Combination Starters System PKZ 2-SP 03/035 PKZ 2/ZM/S-SP motor starters: a higher level of protection and versatility : The PKZ 2/ZM/S-SP is a self-protected starter, the first motor controller

More information

FMotor Circuit Controllers & Circuit Breakers

FMotor Circuit Controllers & Circuit Breakers Motor Circuit Controllers & Circuit Breakers Motor Controllers and MCCBs Series KT7 Motor Circuit Controllers...2 Series KTA7 Base Units...4 Series KTC7 Base Units...6 Series KTB7 Base Units...8 Series

More information

US CATALOG. Miniature circuit breakers

US CATALOG. Miniature circuit breakers US CATALOG Miniature circuit breakers Table of contents 004 024 S(U)200 series miniature circuit breakers UL 489 series 025 048 S200 series miniature circuit breakers UL 1077 series 049 056 Application

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection