Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame
|
|
- Spencer Phillips
- 5 years ago
- Views:
Transcription
1 Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2-
2 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems. They are described by NEMA as,... a device for closing and interrupting a circuit between separable contacts under both normal and abnormal conditions, and furthermore as,... a breaker assembled as an integral unit in a supporting and enclosing housing of insulating material. The NEC describes them as, A device designed to open and close a circuit by non-automatic means, and to open the circuit automatically on a predetermined overload of current, without injury to itself when properly applied within its rating. So designed, Cutler-Hammer circuit breakers protect conductors against overloads and conductors and connected apparatus, such as motors and motor starters, against short circuits. In low voltage distribution systems, there are many varied applications of molded case circuit breakers. Cutler-Hammer offers the most comprehensive family of molded case circuit breakers in the industry. This family of circuit breakers includes: Thermal Magnetic Trip s Electronic rms Trip s Molded Case Switches Motor Protectors Current Limiting s Special Application s World s Special Calibration Special non-ul-listed calibrations are available for certain ambient temperatures other than 0 C and for frequencies other than 50/60 Hz or DC. Reduced interrupting ratings will apply for 00 Hz applications. Maximum thermal calibration is limited to 35A at 00 Hz. Suffix H0 00 Hz 20% Adder Moisture-Fungus Treatment All circuit breaker cases are molded from glass-polyester which does not support the growth of fungus. Any parts which are susceptible to the growth of fungus will require special treatment. Suffix J0 Fungus Treated Freeze-Tested s The circuit breakers may be ordered with freeze testing. This option uses special lubrication and mechanical operation is verified at -0 C. Suffix F0 Freeze Tested Marine Applications F-Frame circuit breakers can be supplied to meet the following marine specifications: U.S. Coast Guard CFR 6 ABS American Bureau of Shipping IEEE 5 These specifications generally require molded case circuit breakers to be supplied with 50 C ambient calibration, special nameplating, and plug-in adapter kits. When plug-in adapter kits are used, no terminals need be supplied. breakers can also be supplied to meet UL89 Supplement SA (Marine Use) and UL89 Supplement SB (Naval Use). UL89 Supplement SA applies to vessels over feet in length. Requirements include 0 C ambient calibration, special labeling, and no use of aluminum conductors or terminals. Suffix H08 Marine UL 89 Supplement SB requires 50 C ambient calibration, vibration testings, special nameplating and no use of aluminum conductors or terminals. Suffix H09 Naval $ % Adder 20% Adder 0% Adder 0% Adder Standards and Certifications Molded case circuit breakers are designed to conform with the following standards: Underwriters Laboratories, Inc., Standard UL89, Molded Case s and Enclosures National Electrical Manufacturers Association Standards Publication No. AB-993, Molded Case s Australian Standard AS 28, Molded Case s British Standards Institution Standard BS 752: Part, Switchgear and Control Gear Part : s Canadian Standards Association Standard C22.2 No. 5, Service Entrance and Branch s International Electrotechnical Commission Recommendations IEC 57-, s Japanese T-Mark Standard Molded Case s South African Bureau of Standards, Standard SABS 56, Standard Specification for Molded Case s Swiss Electro-Technical Association Standard SEV 57-, Safety Regulations for s Union Technique de l Electricite Standard NF C 63-20, Low Voltage Switchgear and Control Gear Requirements Verband Deutscher Elektrotechniker (Association of German Electrical Engineers) Standard VDE 0660, Low Voltage Switchgear and Control Gear, s Conformance with these standards satisfies most local and international codes, assuming user acceptability and simplified application. Molded case circuit breakers equal or exceed Federal Specification Classification W-C-375b requirements for the particular class associated with the circuit breaker frame being considered. 50 C Calibration Add suffix V to Catalog for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50 C ambients. Note: For further information, see, CD-ROM SA.7A.0.T.E. CAT T.E
3 January 200 Vol., Ref. No. [069] Product Line Overview 2 Quick Reference Table 2-. Industrial s H S HS H Cont. Amp. 0 C New E Frame No. Poles, 2, EB 5, is non-interchangeable trip unit and. is interchangeable trip unit. Two-pole circuit breaker, or two poles of three-pole circuit breaker at V DC. Not defined in W-C-375b. Volts Federal UL Listed Interrupting Ratings rms Symmetrical Amperes AC DC of Spec. Trip AC Ratings Volts DC W-C- 375b 20 20/ / / / 37/ / / / / / / / / a 0b, b, 2b, b, 5b a 0b, b, 2b, b, 5b 2c, 3a, 3b a 0b, b, 2b, b, 5b 3b 3b 2c, 3a 3b 2c, 3a 3b 8,000 8,000 EE 5, Y/37 8, ES 5, EH 5, F-Frame ED EDH EDC EHD EHD B B H H H C C New J Frame JE JS JH ,3,,, 37 Y/37 37 Y/37 2b b 3a 3b 8a 3a 22a 3a 22a 2a 00,000 00,000 00,000 00,000 8,000 8,000 8,000 00,000 00,000 00,000 00,000 00,000 8,000 8,000 8,000 8,000 2,000 2,000 Page CAT T.E
4 2-6 Amperes January 200 Vol., Ref. No. [072] 2 Contents Description Page Product Description Technical Data and Specifications Product Selection Thermal-Magnetic s with Non-interchangeable Trip Units Molded Case Switches , and H Bolt-On Panelboard s GFEP Bolt-On Panelboard Ground Fault Protectors s, and H s GFEP Ground Fault Protectors Special Purpose and s Product Description All two- and three-pole circuit breakers are of the common trip type. On all 3-phase Delta (V) Grounded B phase applications, refer to Cutler-Hammer. Single-pole circuit breakers, 5 and 20 amperes. Switching duty rated (SWD) for fluorescent lighting applications. All circuit breakers are suitable for reverse feed use. HACR rated. Technical Data and Specifications Interrupting Capacity Ratings Table 2-2. UL89 Interrupting Capacity Ratings 2 3 Two poles of 3-pole circuit breaker. Time constant is 8 milliseconds minimum. Table 2-3. UL89 Interrupting Capacity Ratings (Continued) H 25 5 through 70A breakers only. Terminal s Interrupting Capacity (Symmetrical Amperes) (ka) Volts AC (50/60 Hz) Volts DC 20 / For line and load-side. Terminals are UL listed as suitable for wire type and size given below. Table 2-. Terminal s Optional Only Pressure (Steel Body) Slotted Cu 3 Not UL listed sizes. Interrupting Capacity (Symmetrical Amperes) (ka) Volts AC (50/60 Hz) Volts DC 20 Y/ / 22 0 H 25 Amperes Standard Terminal Material Clamp (Plated Steel) Pressure (Aluminum Body) Screw Head Slotted Slotted Wire Cu/Al Cu/Al AWG Wire Range 0 0 /0 0 Metric Wire Range (mm 2 ) CAT T.E
5 January 200 Vol., Ref. No. [073] Amperes 2 Product Selection This information is presented only as an aid to understanding Catalog s. It is not to be used to build Catalog s for circuit breakers or trip units. Table 2-5. /Frame Catalog ing System G D K = Pole 2 = 2 Poles 3 = 3 Poles Trip Amperes Suffix K = Molded Case Switch D = Ring Terminals C = Steel Collars V = 50 C J0 = Fungus Proofed R0 = Shock Tested F0 = Freeze Tester HID = High Intensity Discharge CAT T.E
Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001
2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed
More informationCutler-Hammer. January 2001
Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame
Vol. 1, Ref. No. 10499) Product Selection Table 12-56. Types 12-33 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed
More informationTable Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units
-22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,
More informationCutler-Hammer. January 2001
Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere
More informationSwitchboards Instant Service
January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame
12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame
Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere
More informationMolded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.
Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table
More informationInterrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F
-220 Mining Service Circuit s Table -395. Interrupting Capacity Ratings Circuit Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc 240 480 1000Y/577 250 E 2 L E 2 LM 65,000 35,000
More informationL-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W
July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units.
More informationMolded Case. Circuit Breakers. Molded Case Circuit Breakers Contents
January 2001 Vol. 1, Ref. No. [0467] -1 Molded Case Circuit Breakers Contents Description Page Product Line Overview........................................... -2 Product Line Description.......................................
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes 12- Product Selection Table 12-33. s, H, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased
More information2.3. Molded Case Circuit Breakers. Contents
.3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by
More informationPoles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit
More informationTable Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.
-174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40
More informationL-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600
January 01 Vol. 1, Ref. No. [05] 1 Amperes 12- Table 12-99. Type Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Maximum Continuous Ampere 2-Pole 0 0 3-Pole 0 0 V AC Rated, 0V DC
More informationTable Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
-1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip
More informationSeries C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker
FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type
More informationSeries C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationA. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.
16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................
More informationLighting and Power Distribution Panelboards
EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,
More informationAPPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications
Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationType MP-T Type MP-HT Type MP-MT
CIRCUIT BREAKERS 2 Circuit Breakers Full Size (1 per Pole) with INSTA-WIRE 1-Pole Plug-In (120V AC) Type MP-T Type MP-HT Type MP-MT Continuous 10,000A IR 22,000A IR 65,000A IR Current Rating Catalog List
More informationProduct Selection 3-Pole Contactors
- Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the
More informationMOLDED CASE CIRCUIT BREAKERS
EB -, -, -Poles; Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 EHB -, -, -Poles; 4 Volts AC ; Thermal Magnetic and Saf-T-Vue at C 5 0 5 0 5 -Pole, 77 Volts AC, 5 Volts DC➊ Underwriters Laboratories,
More information2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G
. NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................
More informationFeatures 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V
804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More informationTechnical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers.
More information25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,
More informationMOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.
MOLDED CASE CIRCUIT BREAKER BASICS David Castor, P.E. History of MCCBs 1904 - Cutter Manufacturing Co., Philadelphia, produces circuit breakers. They called it the Inverse Time Element breaker, or I-T-E
More informationDIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS
DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection
More informationSeries L9 UL-489 Miniature Circuit Breakers
Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada
More informationProduct Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers
Product Guide QR Circuit Breaker usa.siemens.com/circuitbreakers Advantages to reduce your cost and improve installation flexibility. 250A, 240V AC breakers up to 100kAIC. Updated design includes pushtotrip
More informationNEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems
NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely
More informationTechnical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs
-14 1 Amperes November 08 Eaton s Cutler-Hammer EG Product Description EG breaker is HACR rated. Technical Data and Specifications Table -6. UL 489/IEC 947-2 Interrupting Capacity Ratings Circuit Interrupting
More informationModifications. Marine 50 C Ambient Calibration
1-Pole Bolt-On (120V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 15 B115 B115H B115HH 20 B120 B120H B120HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH
More informationA302DN.40/.63A Thermal Current Motor Starter
4 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A0DN.40/.6A Thermal Current Motor Starter Eaton Corp A0DN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More informationCH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 CH20CAFPN P 20A 20 Combo Arc Fault PN Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product
More informationInstallation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches
Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED. DEATH,
More information22.000A IR. Catalog Number. Price $
Full Size (" per Pole) with INSTA-WIRE -Pole Plug-In (V AC) Type MP-T Type MP-HT Type MP-MT Continuous Current Rating @ C 5 25 35 5 0.000A IR Catalog Number MP5 MP MP25 MP MP35B MP MP5B MP MPB MPB List
More informationFACTORY SEALED CIRCUIT BREAKER PANELBOARDS
FACTORY SEALED CIRCUIT BREAKER BOARDS Applications Hazardous areas due to the potential of explosive gas atmospheres, combustible dusts or easily ignited fibers or flyings and areas subjected to corrosive
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not
More informationModifications. Marine 50 C Ambient Calibration
1-Pole Bolt-On (1V AC) Type BL Type BLH Type HBL 10,000A IR 22,000A IR 65,000A IR @ 40 C 10 B110 B1 B1H B1HH B1 B1H B1HH 25 B125 B125H B125HH 30 B130 B130H B130HH 35 B135 B135H B135HH 40 B140 B140H B140HH
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationDivision 1 Explosionproof Panelboards
Division 1 Explosionproof Panelboards Designed for use in Class 1, Division 1 Zone 1 areas such as petroleum refineries, chemical or petrochemical facilities, the X1Pb panelboards are used to control lighting
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationSeries L9 UL489 Miniature Circuit Breakers
Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More informationProducts :: Circuit Protection :: Thermal Circuit Breakers
Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CLB-Series CLB-Series PDF elibrary The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers
More informationSection 3: Molded Case Circuit Breakers
Section : Molded Case Circuit Breakers Molded Case Circuit Breakers Features...-2 Spectra RMS Circuit Breakers with MicroVersaTrip Plus Trip Units Features...- Molded Case Circuit Breakers Quick Reference
More information1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD
Molded Case Circuit Breakers Industrial Circuit Breakers Section 3 TriBreak Line Integrally Fused Thermal Magnetic Circuit Breakers Integrally Fused Magnetic Circuit Breakers Integrally Fused Molded Case
More informationCutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers
Cutler-Hammer Installation Instructions for the Digitrip OPTIM 550 3-Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Table of Contents Description Page 1.0 General Information......................1
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationTHQL1120AF2 THQL1120AF2 Arc Fault BRKR
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 THQL1120AF2 THQL1120AF2 Arc Fault BRKR Industrial Connections & Catalog Number THQL1120AF2 Manufacturer Industrial Connections
More informationPLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION
Explosionproof, Dust-Ignitionproof With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. 600 Vac Max. 250 Vdc Max. Applications Locations where receptacles are used with stationary or portable
More informationFile E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL
File E14900 Project 98NK40464 January 11, 1999 REPORT on MOTOR CONTROLLERS MAGNETIC Siemens Energy & Automation Inc. Batavia, IL Copyright 1999 Underwriters Laboratories Inc. Underwriters Laboratories
More informationMolded Case Circuit Breakers
600V Circuit Breakers Sentron MD Breakers 480V 600V MD, SMD6 50KAIC 25KAIC HMD, SHMD6 65KAIC 50KAIC CMD, SCMD6 100KAIC 65KAIC Sentron ND Breakers ND, SND6 50KAIC 25KAIC HND, SHND6 65KAIC 50KAIC CND, SCND6
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More information' '!' D Model, 70 to 250 Amperes. W Model, 63 to 250 Amperes. www. ElectricalPartManuals. com
D Model, 70 to 250 Amperes ' '!' ' ' W Model, 63 to 250 Amperes ---------------------- --0 ------------------- Frame Book Page 2 Section 1 - ntroduction Series C Circuit Breakers The new Series C line
More informationPANELBOARDS C1/C2 SECTION 6
SECTION 6 C1/C2 PANELBOARDS Page General Specifications 6-2 Box Sizing 6-2 Gauge Steel Boxes 6-2 Fronts 6-2 Main Breaker Connectors 6-2 Main Lug Connectors 6-2 Selection 6-3 6-5 Main Lugs Only C1 and C2
More informationQ and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units
Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units Bul. 140U DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE ITS IS ENERGIZED.
More informationCircuit Breakers Naval Shipboard Use
Circuit Breakers Naval Shipboard Use Circuit Breakers for Naval Shipboard Use Contents Description Page Description Page Description Page Description Page Selector Guide for Navy Circuit Breakers......
More informationLoadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta
. Eaton Type CH Convertible Family Overview Product Selection Guide CH Loadcenters Description Service Single-phase, three-wire, 20/240 Vac Three-phase, three-wire, 240V corner grounded delta Short-Circuit
More informationMolded Case Circuit Breakers
Panelboard Mounting with INSTA-WIRE 1-Pole Bolt-On (120V AC) e Bolt-On (Common-Trip 120/240V AC) f 10 B210 15 B215 B215H B215HH 20 B220 B220H B220HH 25 B225 B225Hn B225HHn 30 B230 B230H B230HH 35 B235
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers Series G Circuit Breakers.1 Introduction Product Overview......................................... V4-T- Typical Applications........................................ V4-T-
More informationCutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF
Cutler-Hammer Breakers American International Marketing Portland OR 97291-033 Closeout #1287-Cutler-Hammer-Breakers Cutler Hammer Ground-Fault Or Arc-Fault Breaker GFEP120 Cutler Hammer Ground-Fault Equipment
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationUnderwriters Laboratories Inc. Marking Guide. Molded Case Circuit Breakers. 600 Volts or Less April 2002
Underwriters Laboratories Inc. Marking Guide Molded Case Circuit Breakers 600 Volts or Less April 2002 59 *UL has developed the Molded-Case Circuit Breaker Marking Guide to assist AHJs and installers in
More informationA. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:
SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More information30 ma Ground Fault (Earth Leakage) Modules. Product Description
August 2006 0 ma Ground Fault (Earth Leakage) Modules 5-0 ma Ground Fault (Earth Leakage) Modules Clockwise from Left:,, MCCBs Shown with Ground Fault (Earth Leakage) Modules Product Description Eaton
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More information1489-M Circuit Breakers
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable
More informationApplications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim
Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationProtectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.
Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,
More informationOverload Relay Heater Tables
Overload Relay Tables of Elements for Overload Relays General Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for
More informationDBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG
EBR/DBR 30, 60, 100 and 150 Amp Series Receptacles With Disconnect Switch or Circuit Breaker. Weatherproof Spring Cover. Explosionproof, Dust-Ignitionproof 600 Vac Max. 250 Vdc Max. EBR Receptacle Class
More informationVL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS
VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More information