L-Frame LD F. Circuit Breaker/ Frame Ampere Rating. Trip Unit Rating/ Plug Ampere Rating LD T5 7 W
|
|
- Hillary Matthews
- 6 years ago
- Views:
Transcription
1 July 07 5 Amperes -111 Product Selection This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog numbers for circuit breakers or trip units. Table Circuit /Frame ing System 3 F Circuit / Frame B H C C CH CC 2 = 2 Poles 4 = 4 Poles Circuit / Frame Ampere Rating 0 C = Copper Terminals F = Frame Only K = High Magnetic Molded Case Switch V = 50 C (Thermal-Magnetic Trip Units Only) W = Without Terminals X = Load Side Terminals Only Y = Line Side Terminals Only Table Thermal-Magnetic Trip Unit ing System LT 3 T Trip Unit LT = Thermal Magnetic 2 = 2 Poles 4 = 4 Poles Trip Unit Rating/ Plug Ampere Rating 0 T = Trip Unit Thermal-Magnetic Fixed Thermal Adjustable Magnetic V = 50 C Calibration (Thermal-Magnetic Trip Units Only) Table OPTIM Circuit /Frame ing System 3 5 T5 7 W Circuit / Frame H C C CH CC Circuit / Frame Ampere Rating 5 = (Available on Model 50 Only) 0 = (Available on Model 50 Only) Trip 2 = LSI (550 Only) 6 = LSIG 7 = LSIA Trip Model T5 = Model 550 T = Model 50 W = Without Terminals Table Digitrip RMS 3 Trip Unit ing System LES 3 LS P Trip Unit LES = Electronic 4 = 4 Poles Trip Unit Ampere Rating LS LSI LSG LSIG P = % Protected Neutral on 4-Pole Trip Unit CA081E
2 -1 5 Amperes July 07 Product Selection Table s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere Rating at 40 C 2-Pole 0 3-Pole 0 4-Pole 0 Magnetic trip range 5 times continuous ampere rating. Individually packed. Terminal kits contain one terminal for each pole and one terminal cover. Neutral is in right pole. Standard Interrupting Capacity Vac Rated kaic at 480 Vac Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals High Interrupting Capacity Vac Rated kaic at 480 Vac Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals H2 H H2 H2 H2 H2 Ultra High Interrupting Capacity Current Limiting Vac Rated kaic at 480 Vac Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals C2 C C2 C2 C2 C2 Table s, H and C Thermal-Magnetic Circuit s Frame Only Standard Interrupting Capacity Vac Rated kaic at 480 Vac 2-Pole H3 H30 H3 H3 H00 H3 H4 H40 H4 H4 H0 H4 High Interrupting Capacity Vac Rated kaic at 480 Vac C3 C30 C3 C3 C00 C3 C4 C40 C4 C4 C0 C4 Ultra High Interrupting Capacity Current Limiting Vac Rated kaic at 480 Vac 2F H2F C2F 3-Pole 3F H3F C3F 4-Pole 4F H4F C4F Thermal-Magnetic Trip Unit Only For Use with Standard or High or Ultra High Interrupting Frames LT2T LTT LT2T LT2T LT2T LT2T LT3T LT30T LT3T LT3T LT00T LT3T LT4T LT40T LT4T LT4T LT0T LT4T Standard Terminals Only See Page -5 for Optional Terminals 2TA603K 3TA603K 4TA603K Discount Symbol CB-2 CA081E
3 -4 Series G Molded Case Circuit s 15 2 Amperes for UL, CSA & IEC Applications Product Line Overview July 07 Standards and Certifications Cutler-Hammer Molded Case Circuit s from Eaton are designed to conform with the following international standards: Australian Standard AS 2184 and AS Molded Case Circuit s. British Standards Institution Standard EN International Electrotechnical Commission Recommendations IEC Circuit s. Japanese T-Mark Standard Molded Case Circuit s. National Electrical Manufacturers Association Standards Publication No. AB Molded Case Circuit s. South African Bureau of Standards, Standard SANS 156, Standard Specification for Molded Case Circuit s. Swiss Electro-Technical Association Standard SEV 947.2, Safety Regulations for Circuit s. Union Technique de l Electricite Standard NF C 63-0, Low Voltage Switchgear and Control Gear Circuit Requirements. Verband Deutscher Elektrotechnike (Association of German Electrical Engineers) Standard VDE 0660, Low Voltage Switchgear and Control Gear, Circuit s. Global Third-Party Certification Certification marks ensure product compliance with the total standard via the third party witnessing of tests by globally recognized independent certification organizations. KEMA is a highly recognized, independent international organization that offers certification and inspection facilities for equipment in many industries. The KEMA-KEUR mark is the highest certification an electrical product can receive from KEMA. Our IEC Molded Case Circuit s are KEMA tested and certified. These breakers are also listed in accordance with UL 489, as well as CSA C22.2 No KEMA, UL and CSA provide ongoing follow-up testing and inspections to ensure that Cutler-Hammer Molded Case Circuit s continue to meet their exacting standards. General Information Eaton s electrical business, under the Cutler-Hammer brand, offers the widest variety of molded case circuit breakers available today. Designed for electrical and machinery OEMs serving a range of industries and applications, these proven designs incorporate the latest in innovation with the high reliability that has been our hallmark since the advent of the circuit breaker in the 19s. The Series C family ranges from 15 2 amperes, and includes thermalmagnetic breakers, electronic trip breakers, molded case switches, motor circuit protectors, and specially designed breakers for Engine Generator, DC and mining applications. The new Series G line features an average % size reduction, common field-installable internal accessories, and advanced trip unit functionality that eliminates the need for rating plugs. These breakers meet the requirements of UL, CSA, IEC, CCC and CE, allowing the OEM to standardize on a design that meets the needs of their global customer base. CA081E
4 -8 5 Amperes July 07 Technical Data and Specifications Typical Circuit Product Description All Cutler-Hammer Circuit s by Eaton Corporation are HACR rated. circuit breakers are available as individual components (Frame, Trip Unit, Terminals), or factory assembled complete breakers. circuit breakers with non-interchangeable trip units are suitable for reverse feed use. CE marked. Table UL 489 Interrupting Capacity Ratings Circuit B C H, HB CH 2, 3 C, CB CC Interrupting Capacity (ka rms Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc Utilization category A circuit breakers. L/R = 8 milliseconds minimum. 2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip unit only. % rated breakers. Current limiting. Table IEC Interrupting Capacity Ratings Circuit B C H, HB CH C, CB CC 2, 3 Utilization category A circuit breakers. L/R = 8 milliseconds minimum. 2-pole circuit breaker or two poles of 3-pole circuit breaker. Incorporating Thermal-Magnetic trip unit only. % rated breakers Interrupting Capacity (ka Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc I cu I cs I cu I cs I cu I cs I cu I cs CA081E
5 -1 5 Amperes July 07 Dimensions/Weights Table -1. Dimensions in Inches (mm) Width Height Depth 2, (9.6) (279.4).75 (273.1).75 (273.1) 4.06 (3.1) 4.06 (3.1) Table Approximate Shipping Weight, Lbs. (kg) Complete Frame Only Trip Unit , H, C B 18 (8.2) 18 (8.2) (9.1) (9.1) (11.3) (11.3) 14 (6.4) 15 (6.8) (9.1) 3 (1.4) 4 (1.8) 5 (2.3) CA081E
6 July 07 5 Amperes -5 Line and Load Terminals Eaton s Cutler-Hammer line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and wire types. All terminals comply with Underwriters Laboratories Standards UL 486A and UL 486B and CSA Standard C22.2 No. M. Unless otherwise specified, circuit breaker line and load terminals are shipped separately for field installation. The wire connecting terminal is secured with two pan-head, slotted screws and lockwashers which can be checked for the correct torque loading or retightened from the front of the circuit breaker before installation of the conductors. (Applies to all styles.) The circuit breaker line/load terminal conductors are positioned in the conducting holes in the wire connecting terminal and are secured with recessed socket screws which are tightened to the correct torque loading from the front of the circuit breaker. Ordering Information circuit breakers use Cu/AI terminals as standard. When optional copper terminals are required, order by. Specify if factory installation is required. Table -4. Line and Load Terminals Maximum Amperes Terminal Body Material Terminal kits contain one terminal for each pole and one terminal cover. Individually packed. Wire AWG Wire Range/ of Conductors Metric Wire Terminal Terminals with Range mm 2 Control Wire Termination Poles Standard Cu/AI Pressure Terminals Aluminum Cu/AI 4/0 (1) 0 2-Pole Kit 3-Pole Kit 4-Pole Kit Aluminum Aluminum Aluminum Cu/AI Cu/AI Cu/AI 4 4/0 (2) 3/0 0 (2) (2) Pole Kit 3-Pole Kit 4-Pole Kit 2TA401K 3TA401K 4TA401K TA TA602 2TA603K 3TA603K 4TA603K TA602CW 2TA603KCW 3TA603KCW 4TA603KCW Optional Copper and Cu/AI Pressure Terminals Copper Cu 0 0 (2) 0 0 T602 T602CW TA401 or TA603 Terminal (Step- Terminal Requires Terminal Cover and Warning Label. See Inset.) Pan-Head Screws and Lockwashers TA or TA602 or T602 Terminal Pan-Head Screws and Lockwashers (Installed before Cable Clamping Screws) Terminal Cover Warning Label Retainer Circuit Line Terminal Cover Screws Figure -29. Terminals Discount Symbol CB-2 CA081E
7 -234 Internal Accessories Auxiliary Switch July 07 Table F-Frame and HMCP (F) Auxiliary Switch of Contacts a and b Mounting Location (Pole) 1 Left Right or Neutral 2 Left Right or Neutral Standard pigtail lead exit location. Not listed with Underwriters Laboratories, for field installation. Pigtail wire size: 18 AWG (0.82 mm 2 ). 5 volts (Max.), 50/60 Hz switch for use in electronic circuit of micro amperes and 15 Vdc minimum. Not for use on 4-pole circuit breakers. Factory Mounted Field Mounted Connection and Location Field Installation Kits 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block Same Side Rear Opposite Side Same Side A01 A15 A05 A18 A09 A21 A A23 A02 A16 A06 A19 A A22 A13 A24 A03 A17 A07 A A04 A08 A11 A14 A1X1PK E1X1PK A1X1PK A2X1LPK E2X1LPK A2X1RPK E2X1RPK A1X1LTK A1X1RTK A2X1LTK A2X1RTK Table J-Frame and HMCP (J) Auxiliary Switch of Sets of Contacts a and b Mounting Location (Pole) Factory Mounted Field Mounted Connection and Location Field Installation Kits 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block Same Side Rear Opposite Side Same Side 1 Left Right 2 Left Right A01 A05 A09 A Listed with Underwriters Laboratories for field installation or interchangeable trip unit breakers under E Standard mounting location leads exit rear of breaker. Not for use on 4-pole circuit breakers. A02 A06 A A13 A03 A07 A04 A08 A11 A14 A1X2PK A1X2PK A2X2PK A2X2PK A1X2LTK A1X2RTK A2X2LTK A2X2RTK Table K-Frame and HMCP (K) Auxiliary Switch of Sets of Contacts a and b Mounting Location (Pole) Factory Mounted Field Mounted Connection and Location Field Installation Kits 18-Inch (7.2 mm) Pigtail Leads Terminal Block Pigtail Leads Terminal Block Same Side Rear Opposite Side Same Side 1 Left Right 2 Left Right 3 Left Right A01 A05 A09 A A18 A17 A02 A06 A A13 A03 A07 Listed with Underwriters Laboratories for field installation under E Standard mounting location leads exit rear of breaker. s with K-Frame OPTIM 550 can only accept accessories in left pole. Not for use on 4-pole circuit breaker. A04 A08 A11 A14 A15 A16 A1X3PK A1X3PK A2X3PK A2X3PK A3X3LPK A3X3RPK A1X3LTK A1X3RTK A2X3LTK A2X3RTK A3X3LTK A3X3RTK Discount Symbol CB-2 CA081E
Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
-1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased
More informationL-Frame. With Standard Line and. Standard Terminals Only. Catalog Number. Price U.S. $ LDB2300 LDB2350 LDB2400 LDB2450 LDB2500 LDB2600
January 01 Vol. 1, Ref. No. [05] 1 Amperes 12- Table 12-99. Type Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Maximum Continuous Ampere 2-Pole 0 0 3-Pole 0 0 V AC Rated, 0V DC
More informationTable Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.
-174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere
More informationTable Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units
-22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,
More informationCutler-Hammer. January 2001
Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.
More informationMolded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.
Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table
More informationCutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame
Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed
More informationInterrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Y/ ,000 25,000. Frame Only E2L3600F
-220 Mining Service Circuit s Table -395. Interrupting Capacity Ratings Circuit Interrupting Capacity (Symmetrical Amperes) Volts ac (50/60 Hz) Volts dc 240 480 1000Y/577 250 E 2 L E 2 LM 65,000 35,000
More informationSwitchboards Instant Service
January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8
More informationAmperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225
January 1 Vol. 1, Ref. No. [0487] 2 Amperes 12- Product Selection Table 12-33. s, H, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous
More informationCutler-Hammer. January 2001
Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame
Vol. 1, Ref. No. 10499) Product Selection Table 12-56. Types 12-33 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001
2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame
12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection
More informationCutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame
Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationPoles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL
3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit
More information2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G
. NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................
More informationCourtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers.
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers Series G Circuit Breakers.1 Introduction Product Overview......................................... V4-T- Typical Applications........................................ V4-T-
More informationEngine Generator Circuit Breakers
Engine Generator Circuit Breakers Product Description............................................. 2 Application Description........................................... 2 Standards and Certifications......................................
More informationSupplementary Protectors. Circuit Breakers & Circuit Breakers & Supplementary Protectors Contents
-1 May 008 Circuit Breakers & Supplementary Protectors Contents Description Page Series C vs. Series G Typical Applications........................................... - Series G Globally Accepted Breaker
More informationSeries G Moulded Case. Circuit Breakers. Series G Moulded Case Circuit Breakers 1
1 Series G Moulded Case Circuit Breakers Description Series G Globally Accepted Breaker General Information........................................... 2 Product Line Overview.........................................
More informationProduct Line Overview. The Most Logically Designed Contact Assembly
15 0 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased performance in considerably less space than
More information2.3. Molded Case Circuit Breakers. Contents
.3 Molded Case Circuit Breaker Product Family Product Overview Eaton s molded case circuit breakers are designed to provide circuit protection for low voltage distribution systems. They are described by
More informationCH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 CH20CAFPN P 20A 20 Combo Arc Fault PN Breaker Eaton Corp Catalog Number Manufacturer Description Weight per unit Product
More informationF-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:
-0 Motor ircuit Protectors Vol. 1, Ref. No. [058] -rame Table -188. V A, V NMA Starter Size ont. Amps am Motor ull Load urrent Amps MP Trip MP Table -188. V A, V (ontinued) NMA Starter Size ont. Amps am
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationTechnical Data and Specifications. Table UL 489/IEC Interrupting Capacity Ratings. cu I cs I cu I cs I cu I cs I cu I cs I cu I cs
-14 1 Amperes November 08 Eaton s Cutler-Hammer EG Product Description EG breaker is HACR rated. Technical Data and Specifications Table -6. UL 489/IEC 947-2 Interrupting Capacity Ratings Circuit Interrupting
More informationSeries C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker
FD2015 2 Pole 15A FD Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features amperage rating 15 Frame Size F-frame interrupt rating 35 kaic at 480V Poles 2 Trip Type
More information2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description
Molded Case Circuit s Series C.3 Series C Internal Accessories Contents Description Product Overview.......................... Standards and Certifications.................. Quick Reference...........................
More informationMolded Case Circuit Breakers
Series G Circuit Breakers.1 Introduction Product Overview........................................ V4-T- Typical Applications....................................... V4-T- Series G in Eaton Assemblies...............................
More informationMolded Case. Circuit Breakers. Molded Case Circuit Breakers Contents
January 2001 Vol. 1, Ref. No. [0467] -1 Molded Case Circuit Breakers Contents Description Page Product Line Overview........................................... -2 Product Line Description.......................................
More informationSeries C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 HFD3125 HFD3125 125A 3P CKT BRKR Eaton Corp Catalog Number Manufacturer Description Weight per unit Product Category Features
More information25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents
.4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,
More informationComprehensive circuit protection for control panel applications
Industrial control circuit breakers Molded-case circuit breakers Miniature circuit breakers Supplementary protectors Hydraulic-magnetic circuit breakers Comprehensive circuit protection for control panel
More informationSafety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers
Series G Moulded Case Circuit Breakers Product Focus Up to 690 Vac 18kA to 100kA Icu 16-2500 Amperes IEC 60947-2 Safety, Reliability and Performance verified with the KEMA KEUR mark Safety, Reliability
More informationApplication guide. Tmax Link OEM UL 891 Switchboard Program
Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit
More informationTmax Molded Case Circuit Breakers
Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationTmax Molded Case Circuit Breakers
Tmax Molded Case Circuit s Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product technology. Never before has the industry seen such high
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationVL Circuit Breaker DG 150A frame
VL Circuit Breaker DG 150A frame Breaker type Defined by the 3rd character of the catalog number G Global (UL, CSA, IEC, CE, CCC), interchangeable K Global, non-interchangeable W Global, 100% rated, non-interchangeable,
More informationInstallation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches
Installation Instructions for JDB, JD, HJD, JDC, JW HJW, JWC Circuit Breakers and Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED. DEATH,
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More informationControl Circuit Protection
Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC
More informationCutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers
Cutler-Hammer Installation Instructions for the Digitrip OPTIM 550 3-Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Table of Contents Description Page 1.0 General Information......................1
More informationSeries G Moulded Case Circuit Breakers A for IEC & NEMA Applications
15 0 A for IEC & NEMA Applications Product Focus World-class accessories include: Q Circuit breaker W Thermal-magnetic trip unit, integrated on E Frame E Magnetic only trip unit, integrated on E Frame
More informationMolded Case Circuit Breakers
Molded Case Circuit Breakers LMD 800A Frame Sentron Series Type LMXD6 Non-Interchangeable Trip (Assembled Circuit Breaker without Lugs) Blue Label Continuous 2-Pole (3 Pole Width) 3-Pole Current Rating
More informationVL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable
VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable Trip unit type Defined by the 5th character of the catalog number B Thermal-magnetic,
More information2.3. Molded Case Circuit Breakers. Series C. Accessories Selection Guide and Ordering Information
Molded Case Circuit s Series C.3 Accessories Selection Guide and Ordering Information Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationMCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics
Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for
More informationCH215AFIT 2P 15A Arc Fault Shared Neutral/Indpndt Trip BRKR. Features. Dimensions and Weight. Descriptions. Manufacturer Information
Manufacturer Description Weight per unit Product Category CH2AFIT 2P A Arc Fault Shared /Indpndt Trip BRKR Eaton Corp Features Current Rating AMPERE Interrupting Rating 10 KILOAMPERE Poles 2 Terminal Type
More informationInstallation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches
Instruction Leaflet IL 0106001E Contents Description Page Introduction.......................... Installation............................ Manual Operation and Thermal Magnetic Trip Unit Adjustment.......................
More informationXT IEC Power Control Manual Motor Protectors
May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted
More informationTechnical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA
Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power
More informationEnclosures. See Section Typical Description
January 00 Sheet 1187 Motor Starters & Contactors Low Voltage Enclosures General Individual Enclosed, ac Full Voltage.7- Combination Starters Maximum 00 hp, Volts Application Size 1, NEMA 1, Enclosed Magnetic
More informationTechnical data for manual motor starters Type MS325
for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations
More information3. Coils shall be of molded construction
.7-4 Motor Starters & Contactors Low Voltage Enclosures General Non-Combination Starters January 00 Sheet 8 0 7 8 9 4 Non-Combination Starters Maximum hp, Volts Typical Non-Combination Starter Application
More informationAPPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications
Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection
More informationSeries L9 UL-489 Miniature Circuit Breakers
Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada
More informationMiniature Circuit Breakers
S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting
More informationPowerPact B. Molded case circuit breakers and switches from A
PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member
More informationVL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS
VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless
More informationSeries L9 UL489 Miniature Circuit Breakers
Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded
More informationBulletin 190-M Compact Starters. Selection Guide
Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located
More informationProduct Selection 3-Pole Contactors
- Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the
More informationCutler-Hammer Breakers. Cutler-Hammer Circuit Breaker Afci 1 Pole 15A BR115AF CUTLER HAMMER CIRCUIT BREAKER AFCI 1 POLE 15A BR115AF
Cutler-Hammer Breakers American International Marketing Portland OR 97291-033 Closeout #1287-Cutler-Hammer-Breakers Cutler Hammer Ground-Fault Or Arc-Fault Breaker GFEP120 Cutler Hammer Ground-Fault Equipment
More informationBulletin 140U R-Frame Molded Case Circuit Breakers
R-Frame Molded Case Circuit Breakers Selection Guide Product Selection Product Selection 2500 A, R-Frame UL 489 Note: Terminal box lugs must be ordered separately. CSA 22.2, No. 5 IEC 60947-2 CE KEMA-KEUR
More informationFeatures 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V
804 South Street 7964-76, TX Nacogdoches Phone: 96-69-794 Fax: 96-60-468 A07NN A Man Motor Protector Eaton Corp Catalog Number A07NN Manufacturer Eaton Corp Description Manual Motor Starter, Motor Protector;
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationMS General Information Extended Product Type: MS
MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual
More informationTMC 91H is now TMC 60 C Series
TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the
More informationMolded Case Circuit Breakers
Type SND6 Molded Case Circuit Breakers SND 1200A Frame Digital Solid State Sentron Sensitrip III Series Type SHND6 Current Limiting Type SCND6 Blue Label Black Label Red Label Catalog Current Price SND69800A
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current
More informationPVGard 600 and 1000 Vdc solar photovoltaic circuit breakers
Supersedes October 2013 photovoltaic circuit breakers Contents Description Page Product description........................ 1 PVGard 600 Vdc........................... 2 Technical data...........................
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationSENTRON VL Series Product Specifications
SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped
More informationDMX 3 -I 2500 switch disconnectors
8704 LIMOGES Cedex Telephone : 0 0 87 87 Fax : 0 0 88 88 DMX 3 200 circuit breakers DMX 3 -I 200 switch disconnectors References: 0 28 20 / 21 / 22 / 23 / 24 / 2 / 2 / 30 / 31/ 32/ 33/ 34 / 3 / 3 / 40
More informationProducts :: Circuit Protection :: Thermal Circuit Breakers
Products :: Circuit Protection :: Thermal Circuit Breakers Thermal Circuit Breaker CLB-Series CLB-Series PDF elibrary The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers
More informationParts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation
More informationParts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationTechnical Information
-100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42
More informationThese devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series
PGFM Series GFCI Ground Fault Protection Sensing Module INTRODUCTION The LineGard PGFM GFCI Sensing Module is a ground fault or equipment leakage sensing device designed and manufactured by North Shore
More informationBulletin 1489 Circuit Breakers. Selection Guide
Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed
More informationMolded Case Circuit Breakers
SMD 800A Frame Digital Solid State Sentron Sensitrip III Series Selection Type SMD6 Type SHMD6 Current Limiting Type SCMD6 Blue Label Black Label Red Label Catalog Current List SMD69600A 600 SMD69700A
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationPowerPact Circuit Breakers for Control Panel Disconnects Class 0611
Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationCutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information
Cutler-Hammer Installation Instructions for Undervoltage Release Mechanism (Handle Reset) for EHD, FDB, FD, HFD, FDC, FW, HFW, FWC Circuit Breakers and Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL
More informationMultistandard offer for OEM applications. Single solution source for business without borders
Multistandard offer for OEM applications Single solution source for business without borders 1 Improving customer satisfaction means producing industrial machines that are compliant to international standards,
More information