SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A
|
|
- Gavin Wilkins
- 5 years ago
- Views:
Transcription
1 Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability > Safety of property and personnel > Simplicity > Easy assembling Function SIRCO 3 x 600 A SIRCO non-fusible disconnect switches are heavy duty switches that break and make power circuits on and off load and provide safety isolation. These switches are extremely durable and are tested and approved for use in the most demanding applications. Conformity to standards (1) > IEC > UL98, Guide WHTY, file E > CSA 22.2#4, Class , file * General characteristics Positive break indication. Fully visualized disconnection. High thermal and dynamic withstand. Severe utilization categories. High electrical and mechanical endurance. (1) Product reference on request. Customized solutions > Please consult us 32 General Catalog UL/CSA Ed. 1
2 References Rating (A) No. of poles Switch body Direct handle External handle Shaft for external handle Auxiliary contacts Terminal protection screens Terminal Lugs kits 100 A 200 A 0 A 600 A 800 A 1000 A S2 type 1, 3R, F 2111 (1) Red/Yellow 1, 3R, G 2111 (1) 4, 4X 142D 2111 (1) Red/Yellow 4, 4X 142E 2111 (1) S3 type 4, 4X 143D 3111 (1) Red/Yellow 4, 4X 143E 3111 (1) 200 mm 7.9 inches mm 12.6 inches mm 15.7 inches mm 7.9 inches mm 12.6 Inches mm 15.7 Inches st contact NO/NC nd contact NO/NC (2) (3) (4) (2) (3) (4) (4) (4) (4) (4) (4) (4) (4) 3954 (4) A (1) Defeatable handle. (2) Top. (3) Bottom. (4) Top or bottom. (5) Max. 4 ACs. Accessories Direct operation handle Rating (A) Color Handle type Reference B H acces_135_a_2_cat acces_114_a_1_cat H type handle B type handle General Catalog UL/CSA Ed. 1 33
3 Accessories (continued) External operation handle The interlocking function of the front external handle prevents the user from opening the door of the enclosure when the switch is in the "ON" position or when the switch is padlocked in the "OFF" position (S1, S2, S3 and S4 type handles only). Front handle I - 0 Opening the door when the switch is in the "ON" position is possible by defeating the interlocking function with the use of a tool (authorized persons only). The interlocking function is restored when the door is closed. Rating (A) Handle type Color Nema type Reference S2 1, 3R, F S2 Red/Yellow 1, 3R, G S2 4, 4X 142D S2 Red/Yellow 4, 4X 142E S3 4, 4X 143D S3 Red/Yellow 4, 4X 143E S4 4, 4X 144D S4 Red/Yellow 4, 4X 144E 3111 Front handle heavy duty I - 0 with metallic lever Rating (A) Handle type Color Nema type Reference S2 4, 4X 142D S2 Red/Yellow 4, 4X 142E S3 4, 4X 143D S3 Red/Yellow 4, 4X 143E S4 4, 4X 144D S4 Red/Yellow 4, 4X 144E 3911 S2 type handle S3 type handle Heavy duty S2 type handle acces_236_a_2_cat acces_166_a_2_cat acces_150_a_1_cat S4 type handle acces_152_a_2_cat Shaft for external handle Standard lengths: in / 200 mm, in / 320 mm, in / 0 mm. Other lengths: please consult us. Rating (A) Dimension X (in) Dimension X (mm) Handle type Length (inches) Length (mm) Reference S S S S S3, S S3, S S3, S S3, S (1) (1) UL pending, please consult us. Alternative color S-type handle cover acces_369_a_1_cat X acces_202_a acces_144_b_1_cat For single lever handles type S1, S2, S3 and double lever handle, type S4. Other colors: please consult us. Handle color Pack qty Handle type Reference Light grey 50 S2, S Dark grey 50 S2, S Light grey 50 S Dark grey 50 S acces_198_a_1_cat S-type handle raiser Enables S-type handles to be fitted in place of existing older style Socomec handles. Adapter can also be utilized as a spacer to increase the distance between the panel door and the handle lever. Dimensions Adds 12 mm to the depth. Handle color Pack qty Nema type Reference 10 1, 3R, acces_187_a_1_cat 34 General Catalog UL/CSA Ed. 1
4 Shaft guide for external handle This accessory makes shaft introduction easier with up to 15 mm misalignment. Description Required for a shaft length over 0 mm. Reference Shaft guide acces_260_a_2_cat Auxiliary Contacts Pre-break and color of positions 0 and I. Electrical characteristics A300 for 100 to 0 A. A600 for 600 to 1200 A. NO/NC contact for A Rating (A) No. of AC Reference st nd acces_076_a_1_cat NO/NC contact for A Rating (A) No. of AC Reference st nd Terminal screens Top or bottom protection against direct contact with terminals or connection parts. Rating (A) No. of poles Position Reference top bottom top / bottom top bottom top / bottom bottom (1) 600 bottom (1) bottom (1) bottom (1) (1) Load side screen, the line side is included with the switch. acces_079_a_1_cat Terminal lugs Connection of bare copper cables onto the lugs (without lugs). Rating max (A) Wires range No wires per lug Lugs per kit Wires Reference #6-300MCM 1 2 Cu / Al #6-300MCM 1 3 Cu / Al #6-300MCM 1 4 Cu / Al #4-600MCM 1 2 Cu / Al #4-600MCM 1 3 Cu / Al #4-600MCM 1 4 Cu / Al x (#6-350MCM) 2 2 Cu / Al x (#6-350MCM) 2 3 Cu / Al x (#6-350MCM) 2 4 Cu / Al x (#2-600MCM) 1 2 Cu / Al x (#2-600MCM) 2 3 Cu / Al x (#2-600MCM) 2 4 Cu / Al x (#2-600MCM) 2 6 Cu / Al x (#2-600MCM) 2 8 Cu / Al ul_032_a General Catalog UL/CSA Ed. 1 35
5 Characteristics Characteristics according to UL98/CSA22.2#4 SIRCO UL98 - General use rating (A) 100 A 200 A 0 A 600 A 800 A 1000 A 1200 A Short circuit rating at 600 VAC (ka) Type of fuse J J J J L L L Max. fuse rating (A) Max. motor hp / FLA 3 ph motor max VAC 30 / / / / / / / VAC 75 / / / / / / / VAC 100 / / / / / / / 472 Max. motor hp / FLA 1 ph motor max VAC 10/50 10/50 Max. motor hp / DC FLA motor max. 125 VDC (1) 10 / / / / VDC (2) 15 / / / / 173 Connection terminals Min. connection section / AWG #6 #6 2x #6 / #4 2x #2 4x #2 4x #2 4x #2 Max. connection section / AWG 300MCM 300MCM 2x 350 / 600MCM 2x 600MCM 4x 600MCM 4x 600MCM 4x 600MCM Mechanical characteristics Endurance (number of operating cycles) Operating torque (lbs.in/nm) 88.5/ / / / / / /50 Auxiliary contacts Electrical characteristics A300 A300 A300 A600 A600 A600 A600 (1) 2 pole in series. (2) 3 pole in series. Characteristics according to IEC SIRCO UL to 1200 A Thermal current Ith ( C) 600 A 800 A 1000 A 1200 A Rated insulation voltage Ui (V) Rated impulse withstand voltage Uimp (kv) Rated operational currents I e (A) Rated voltage Utilization category A (1) A (1) A (1) A (1) 0 VAC AC-22 A VAC AC-23 A VAC AC-22 A VAC AC-23 A Connection Min. Cu cable cross section (mm²) 2 x x x 2 Min. Cu busbar section (mm²) 2 x 30 x 5 2 x x 5 2 x 50 x 5 2 x 60 x 5 Operational power in AC-23 (kw) At 0 VAC without prebreaking AC in AC23 (kw) (2)(3) At 500 VAC without prebreaking AC in AC23 (kw) (2)(3) At 690 VAC without prebreaking AC in AC23 (kw) (2)(3) Overload capacity (U e 415 VAC) Rated short-circuit making capacity Icm (ka peak) (4) (1) Category with index A = frequent operation. (2) A/B: Category with index A = frequent operation - Category with index B = infrequent operation. (3) The power value is given for information only, the current values vary from one manufacturer to another. (4) For a rated operating voltage Ue = 0 VAC. 36 General Catalog UL/CSA Ed. 1
6 Dimensions (in/mm) 100 to 0 A M J1 U Z Y 1 W R1 H N AA AC V K CA R2 sirco-ul_011_a_2_x_cat T F AD C 1. Terminal shrouds Rating (A) Overall dimensions Terminal shrouds Switch body Switch mounting Connection J1 J1 M M Unit C AC AD F 3p. F 4p. H 3p. 4p. K 3p. 4p. N R1 R2 T U V W Y Z AA CA in mm in ,18 0,43 0,14 1,35 6,3 0,6 mm ,5 34, in mm , A H M Z J Ø 0.51 Ø 13 Y X AC N N1 AA F sirco_107_d_1_x_cat Rating (A) 600 Terminal shrouds Switch body Switch mounting Connection Unit AC F 3p. F 4p. H J 3p. J 4p. M 3p. M 4p. N N1 AA Z in mm General Catalog UL/CSA Ed. 1 37
7 Dimensions (in/mm) (continued) 800 to 1200 A H Z Ø 0.43 Ø 11 J M Y X N sirco_228_d_1_x_cat AC N2 N F Terminal shrouds Switch body Switch mounting Rating (A) Unit AC F 3p. F 4p. H J 3p. J 4p. M 3p. M 4p. N N1 800 in mm in mm in mm to 0 A Front direct handle to 1200 A Front direct handle sirco-ul_027_a_1_x_cat sirco_267_b_1_x_cat Mounting orientation 3/4 pole sirco-ul_028_a_1_x_cat 38 General Catalog UL/CSA Ed. 1
8 External handles dimensions (in/mm) 100 to 0 A Front operation Handle type Direction of operation Door drilling S2 type 0 90 Ø 3.07 Ø I Ø 1.46 Ø 37 4 Ø Ø poign_013_a_1_us_cat 600 to 1200 A Handle type Front operation Direction of operation Door drilling S3 type Ø3.07 Ø78 90 I Ø 1.46 Ø to 1200 A Ø Ø 7 poign_046_a_1_gb_cat Front operation Handle type Direction of operation Door drilling S4 type I Ø3.07 Ø78 Terminal lugs (in/mm) 100 to 200 A A 90 0 A Ø Ø 7 Ø 1.46 Ø to 1200 A poign_036_a_1_us_cat Ø sirco_115_b_1_us_cat Ø 0.4 Ø sirco-ul_010_b_1_us_cat sirco-ul_026_b_1_us_cat Ø sirco_116_b_1_us_cat 300 kcmil 600 kcmil 2 x 350 kcmil 2 x 600 kcmil General Catalog UL/CSA Ed. 1 39
SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A
The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.
More informationSIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A
Conformity to standards (1) Changeover switches svr-ul_14_b_1_cat > EC 6947-3 > UL98, Guide WHTY, file 1138 > UL18, Guide WPYV, file 31792 > CSA 22.2#4, Class 4651-2 (1) Product reference on request. svr_136_a_2_cat
More informationsirco-ul_004_b_cat 100A to 2000A - 600VDC and 1000VDC UL98B Listed
site_317_a sirco-ul_22_b_cat sirco-ul_4_b_cat 1A to 2A - 6VDC and 1VDC UL98B Listed  Function non fusible disconnects are heavy duty switches that break and make 6VDC or 1VDC photovoltaic circuits on
More informationNon-fusable disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages
More informationSIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A
Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong
More informationSIRCO PV Load break switches for photovoltaic applications for use up to 1500 VDC from 100 to 3200 A
Load break switches new SRCO-pv_023_a_1_cat The solution for > Residential buildings. > Buildings. > Solar parks. Strong points Function SRCO PV are manually operated multipolar load break switches. They
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationFUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A
Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 new sircopv_059_a cat The solution for > Combiner box > Recombiner box > Inverter Function SIRCO PV UL98 non fusible disconnect switches are heavy duty
More informationSIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC
Load break switches sircopv_058_a cat SIRCO PV UL98 from 00 to 2000 up to 500 VDC sircopv_059_a cat Strong points > Patented switching technology. > Positive break indication. > Up to 000 VDC as per characteristics
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationSIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC
Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationSIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC
and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar
More information125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request
125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for
More informationWhat you need to know. Â Conformity to standards
SIRCO PV Load break switches for solar applications sirco_343_a_1_cat  What you need to know A solar electrical installation is an application that requires switching devices fully meet the needs of operational
More informationFUSIBLE DISCONNECT SWITCHES
FUSIBLE DISCONNECT SWITCHES HIGHLIGHTS: Double break contacts per pole up to 400 A Touch safe fuse covers/line shrouding standard Service Entrance Rated Compact Footprints Front operated switches Side
More informationLoad break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...
Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch
More informationSIRCO M and MV Universal load break switches from 16 to 160 A
SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually
More informationSIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function
The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole
More informationContents. Volume 5 Motor Control and Protection CA E December
Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions
More informationSIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.
Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity
More informationSIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points
Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationSIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A
Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented
More informationSHORT FORM CATALOGUE. ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98
2014 2015 SHORT FORM CATALOGUE ATYS & SIRCOVER Transfer Switch Equipment for your power availability UL 1008 & UL 98 ATyS UL 1008 Motorized Transfer Switching Equipment from 100 to 400 A Transfer switches
More informationAn innovative technology
The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,
More informationLoad Break Disconnect Switches FSLBS
Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable
More informationNon-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.
disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty
More informationFUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES
FUSIBLE DISCNECT SWITCHES (UL98) GM SERIES Three-pole disconnect switches with fuse holder (UL98) GMF...030 C12 GMFJ 100 C03 GMFJ 400 C03 GMFJ 800 C03 Add-on blocks GMX10 10 GMX3... GMX8 00 GMX8 01 GMX5...
More informationATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions
to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They
More informationUL/CSA Non-fused Disconnect Switches
Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationMANUALLY OPERATED CHANGEOVER SWITCHES
are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application: NORMA/EMERGENCY Application: UPS,
More informationNon-Fused Load Break Switches FSSC, SX, SXDC, SC
UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty switches are designed with the most up-todate disconnect
More informationVistop TM isolating switches 63 to 160A
DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary
More informationBussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application
Bussmann Open and Enclosed Rotary Disconnect Switches Exceptional Breadth and Availability f Your Application 2 Visit us on the web at www.cooperbussmann.com/disconnects Table of Contents Compact Circuit
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationCat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
Product Selection UL/CSA Fused Disconnect Switches Cat. No. 194R-J30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.
More informationGeneral information about motor protection
Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationSection Contents. Disconnect Switches
Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330
More informationCATALOGUE MARINE APPLICATIONS. Energy performance solutions
CATALOGUE MARINE APPLICATIONS Energy performance solutions 2017 2018 Marine Certifications Our certified products As an independent manufacturer, we, at Socomec are committed to adapting the range and
More informationSD Series Non-Fused Load Switches
SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination
More informationBreakers and Switches. Switches Switch-disconnectors OT and OTM
Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 250
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 Reference(s) : 420 205/ 207/ 208/209/ 215/ 217/ 218/ 219/ 235/ 237/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3.
More informationfootprint of traditional fusible switches
Disconnect switches Contents Section page Description Compact Circuit Protector (CCP) disconnect switches Class CC, UL supplemental and IEC 0x38mm (CCP) -3 Class CF CUBEFuse (CCP-CF) 4-5 Compact Circuit
More informationPowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)
PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................
More informationSwitch-disconnectors OT , OETL 3150
Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated
More informationATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A
ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat
More informationATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A
Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationBulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide
F Fixed-Depth Flange-Mounted Disconnect Switches Selection Guide F Fixed-Depth Flange-Mounted Disconnect Switches Product Cat. No. 1494F-N Disconnect Switch with Cat. No. 1494F-F Fuse Block Adapter Plate
More informationSWITCH DISCONNECTORS PLANET -SWITCH.
SWITCH DISCONNECTORS 6A to 600A ratings Versions: direct operating handle, door coupling and in housing Wide range of accessories Types for photovoltaic applications up to 50A. PLANET -SWITCH SEC. PAGE
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationUL 98 Fusible Disconnect Switches
UL 98 Fusible isconnect witches ICONNECT WITCHE Mersen s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are service entrance devices capable of fully
More informationDPX Magnetic only
87045 LIMOGES Cedex Phone :+33 5 55 06 87 87 Fax :+33 5 55 06 88 88 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (NEXT) 2 4. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 5. CONFORMITY
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationUL Enclosed Disconnect Switches (Fused and Non-Fused)
Product Selection UL Enclosed Disconnect Switches (Fused and Non-Fused) Catalog Number Explanation 194R-K Non-Metallic Enclosure UL Type 3/4/4X, IP66 194R-F Painted Steel Enclosure UL Type 3/4/12, IP66
More information15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A
TyS t M - TyS g M utomatic Transfer Switching Equipment Transfer switches new The solution for > High Rise uildings > Data centre > Healthcare buildings TyS g M I-0-II P atys-mg_001_b_1_cat Function TyS
More informationSERIES D DISCONNECTS SWITCHES. 16 Amp Amp 600 & 1000 Volt. Featuring:
SERIES D DISCONNECT SWITCHES 1 Amp 0 Amp 00 & 0 Volt Load Make/Load Break Positive Opening Compact Size Modular Construction Horse Power Rated Custom Versions Featuring: Auto Alignment Shaft Wide Handle
More informationSwitching, control and protection solutions for solar applications
Switching, control and protection solutions for solar applications continuous performance www.socomec.com Summary SIRCO M PV Manually operated modulable and modular switches p. 4 SIRCO MV PV Manually
More informationBreakers and switches. Enclosed switches Heavy duty safety switches Fusible and non-fusible Amperes
Breakers and switches Enclosed switches Heavy duty safety switches Fusible and non-fusible 30 1200 Amperes Heavy duty fusible and non-fusible safety switches 30 1200 Amperes Features, product overview
More informationATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A
Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated
More informationSFS-UFS Single Foot Switches
SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes
More information34.2 R5 Series (UL 508) Non-Fusible 16 80A MTS Manual Transfer Switches
Rotary Discconects.1 Introduction UL /CSA Standards for Disconnect Switches.................. UL Standards for Electrical Machinery......................... Eaton Solutions for UL 508 and NFPA 79........................2
More informationSwitch Disconnectors
Switch Disconnectors Reversible terminals allow the same switch body to be used in both front & rear mount applications 25A - 32A - 50A - 63A - 80A - A versions available Neutral pole, additional poles
More informationTeSys GS. Data for Designers. Contents
TeSys GS Technical Data for Designers Contents Characteristics: > switch-disconnector... B5/16 to B5/21 > auxiliary contacts...b5/22 Dimensions... B5/23 to B5/31 Schemes...B5/31 B5/15 Characteristics -
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 160
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY
More information.1 Introduction UL/CSA Standards for Disconnect Switches UL 98 Enclosed and Deadfront Switches (CSA C22.2 No. 4) These requirements cover enclosed or
Rotary Discconects.1 Introduction UL /CSA Standards for Disconnect Switches........................ UL Standards for Electrical Machinery............................... Eaton Solutions for UL 508 and NFPA
More informationCertifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE
Bulletin R Overview Bulletin R Next Generation Global Fused and Non-Fused Disconnects 0 A A Sizes Fused Switch Versions: - BS - DIN - CSA HRCII-C - CSA HRCI-MISC - UL Class J - UL Class CC - NFC Non-Fused
More informationOverview for Fusible Disconnect Switches
Overview for Fusible Disconnect Switches CFD30CC3 FD800L3 CFD30AJ3 CFD60J3 CFD100J3 FD400J3 FD600J3 FD800L3 number 3 pole CFD30ACC3 CFD30AJ3 CFD60J3 CFD100J3 CFD200J03 FD400J3 FD600J3 FD800L3 General purpose
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationfor Non-Fusible Disconnect Switches
Overview for Non- Disconnect Switches CDNF16 CDNF100A3 CDNF16A3, CDNF25A3, CDNF32A3 CDNF30A3, CDNF60A3, CDNF100A3 CDNF160 number 3 pole CDNF16A3 CDNF25A3 CDNF32A3 CDNF45A3 CDNF63A3 CDNF30A3 CDNF60A3 CDNF100A3
More informationDPX earth leakage DPX 3 -I earth leakage
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationSPEEDFAX TM 2011 Disconnect Switches Contents
SPEEDFAX TM 2011 Disconnect es Contents Compact Non-Fusible es Rotary and Toggle Selection 5-2 5-4 Dimensions and Wire Ranges 5-5 Type VBII (30-600A) Features and Ordering Information 5-6 and Handle Selection
More informationGeneral Characteristics
from 63 to 31 lbs_037_a he solution for > ain switchboard > Distribution panel > Emergency switching > us tie Function he CEC ensures making and breaking on load and security breaking of any low voltage
More informationTechnical data OT16E3 OT160E3 UL & CSA
Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More informationDRX 125 Circuit breaker (not adjustable)
87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 272 20/21/22/23/24/25/26/27/55/56/57/58/59/60 INDEX PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 3. DIMENSIONS (continuation) 2 4.
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationB115...B180 RF200 RFN200 B250...B400 RF400 RFN400
Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,
More informationDisconnect Switches Compact, Heavy-Duty
Table of Contents Bussmann Disconnect Switches Compact, Heavy-Duty Table of Contents Fusible Disconnect Switches...Page 2 Fusible Non-Fusible Disconnect Switches...Page 29 Non-Fused Enclosed Fusible Disconnect
More informationBulletin 1494V Variable Depth Flange-Mounted Disconnect Switches. Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches
2 Bulletin 1494 NEMA Disconnect Switches Section Overview Bulletin 1494V Variable Depth Flange-Mounted Disconnect Switches Open Type, Fusible 30 600 A Open Type, Non-Fusible 30 600 A Page 2-3 Bulletin
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationGV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features
Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator
More informationLow Voltage Products. Switches Switch-disconnectors OT and OETL
Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC lth /A le /AC22A, 415V le /AC23A, 415V... OT16F OT63F OT100F OT160E OT25F OT80F OT125F OT40F 25 32 40 63 80 115 125
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationWall mounted switchgear
Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page
More informationSWITCH FUSES 3KL71 from 32A to 800A Description
from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used
More informationCompact Circuit Protector
Supersedes February 2019 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP2) 2011/65/EU CCP2 switch up to 100 A 200 A CCP2 switch 400 A CCP2 switch Contents Page 30, 60 and 100 amp switches s and
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationCircuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases
Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters
More information