File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd.

Size: px
Start display at page:

Download "File E63614 Project 01SC January 10, 2002 REPORT COMPONENT - MOTOR CONTROLLERS, MAGNETIC. Fujitsu Takamisawa Component Ltd."

Transcription

1 File E63614 Project 01SC10795 January 10, 2002 REPORT ON COMPONENT - MOTOR CONTROLLERS, MAGNETIC Fujitsu Takamisawa Component Ltd. Nagano, Japan Copyright 2001 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above-named company to reproduce that portion of this Report consisting of this Cover Page through Page 5.

2 File E63614 Vol. 1 Sec. 25 Page 1 Issued: DESCRIPTION PRODUCT COVERED: * USR - Magnetic, Motor Controller, Model Series Type K1 or K1T, with or without prefix FTR-, followed by A, C, J or B, followed by K or L, followed by 005 through 110, followed by W, E or T, may be followed by -LB, -MA, -MB or -LA, may be followed by KS or -KW, may be followed by -HT or -01 through -99. USR, CNR - Magnetic, Motor Controller, Model Series Type K1, with or without prefix FTR-, followed by L, may be followed by D, followed by A or C, followed by K, followed by 005 through 024, followed by T or W, may be followed by -01 through -99. GENERAL: These devices are relays controlled by a DC rated coil, with magnetically operated contacts. The contact arrangements include single-pole single-throw, normally open, single-pole single-throw, normally closed, and single-pole double-throw, normally open and normally closed. These devices are provided with terminals for direct mounting onto printed circuit boards. These devices are intended for use in industrial control equipment. Select models are intended for use in temperature indicating and regulating equipment. *

3 File E63614 Vol. 1 Sec. 25 Page 1A Issued: and Report New: ELECTRICAL RATINGS: Contact: Single stable: Form C: Model FTR-K1CK(#1)W all 85 C except as noted 16 A, 24 V dc, Resistive, 50,000 cycles 16 A, 277 V ac, Resistive, 50,000 cycles 16 A, 277 V ac, Resistive, 100,000 cycles (NO contact only) 20 A, 277 V ac, Resistive, 6000 cycles (75 C) 1/8 hp, 125 V ac, 30,000 cycles TV-5, 250 V ac, 25,000 cycles, (NO contact only) Model FTR-K1CK(#1)(E) all 85 C except as noted 16 A, 24 V dc, Resistive, 6000 cycles 16 A, 277 V ac, Resistive, 50,000 cycles 20 A, 277 V ac, Resistive, 6000 cycles (75 C) 1/8 hp, 125 V ac, 30,000 cycles

4 File E63614 Vol. 1 Sec. 25 Page 2 Issued: and Report Revised: RATINGS: (Cont d.) Model FTR-K1CK(#1)(E)-HT, all 105 C 16 A, 24 V dc, Resistive, 6000 cycles 16 A, 277 V ac, Resistive, 50,000 cycles 1/8 hp, 125 V ac, 30,000 cycles Form C: Model FTR-K1CK (#1)W-MA and W-MB all 85 C 12 A, 24 V dc, Resistive, 6000 cycles 16 A, 24 V dc, Resistive, 6000 cycles 16 A, 277 V ac, Resistive, 50,000 cycles 12 A, 277 V ac, Resistive, 6000 cycles 1/2 hp, 277 V ac, 6000 cycles 1/3 hp, 125 V ac, 6000 cycles 1/8 hp, 125 V ac, cycles Model FTR-K1CK(#1)(W)-HT, all 105 C 16 A, 24 V dc, Resistive, 30,000 cycles 16 A, 277 V ac, Resistive, 50,000 cycles 20 A, 277 V ac, Resistive, 6,000 cycles 1/8 hp, 125 V ac, 30,000 cycles Model FTR-K1CL(#2)(W)-LA, all 85 C 10 A, 277 V ac, Resistive, 100,000 cycles * Model FTR-K1CK(#1)T-KS - all 105 C 16 A, 277 V ac, Resistive, 30,000 cycles TV-8, 120 V ac, 25,000 cycles (NO contact only) * Model FTR-K1CK(#1)W-KW - all 105 C 16 A, 277 V ac, Resistive, 10,000 cycles Form A: Model FTR-K1AK(#1)(T) all 85 C except as noted 16 A, 24 V dc, Resistive, 100,000 cycles 16 A, 277 V ac, Resistive, 100,000 cycles 20 A, 277 V ac, Resistive, 6000 cycles (75 C) TV-5, 120 V ac, 25,000 cycles Pilot duty, Code A300, 6000 cycles Model FTR-K1AK(#1)(E) all 85 C except as noted 16 A, 24 V dc, Resistive, 10,000 cycles 16 A, 277 V ac, Resistive, 100,000 cycles 20 A, 277 V ac, Resistive, 6000 cycles (75 C) Pilot duty, Code A300, 6000 cycles

5 File E63614 Vol. 1 Sec. 25 Page 2-1 Issued: ELECTRICAL RATINGS: (Cont d.) * Model FTR-K1AL(#1)(E,W)-LB all 85 C except as noted 10 A, 277 V ac, Resistive, 6000 cycles 1/3 hp, 125 V ac, 30,000 cycles 1/2 hp, 277 V ac, 6000 cycles Model FTR-K1AK (#1)W-MA and W-MB all 85 C 16 A, 24 V dc, Resistive, 10,000 cycles 12 A, 24 V dc, Resistive, 6000 cycles 16 A, 277 V ac, Resistive, 100,000 cycles 12 A, 277 V ac, Resistive, 6000 cycles 1/2 hp, 277 V ac, 6000 cycles 1/3 hp, 125 V ac, 6000 cycles

6 File E63614 Vol. 1 Sec. 25 Page 2A Issued: ELECTRICAL RATINGS: (Cont d.) Form A: Model FTR-K1AL (#2)W-LA all 85 C 10 A, 277 V ac, Resistive, 6000 cycles 1/2 hp, 277 V ac, 6000 cycles 1/3 hp, 125 V ac, 6000 cycles Model FTR-K1T(A, J)K (#1)( T)-HT all 105 C 17 A, 277 V ac, Resistive, 100,000 cycles 1 hp, 277 V ac, 30,000 cycles TV-5, 120 V ac, 25,000 cycles Pilot Duty, code A300, 6,000 cycles Model FTR-K1AK(#1)(E, T)-HT all 105 C 16 A, 24 V dc, Resistive, 10,000 cycles (Type E) 16 A, 24 V dc, Resistive, 100,000 cycles (Type T) 16 A, 277 V ac, Resistive, 100,000 cycles 20 A, 277 V ac, Resistive, 6,000 cycles (Type T) TV-5, 120 V ac, 25,000 cycles (Type T only) Pilot duty, Code A300, 6000 cycles Model FTR-K1AK(#1)T-KS - all 105 C 16 A, 277 V ac, Resistive, 100,000 cycles TV-8, 120 V ac, 25,000 cycles Model FTR-K1AK(#1)W-KW - all 105 C 16 A, 277 V ac, Resistive, 20,000 cycles 20 A, 277 V ac, Resistive, 6,000 cycles Form B: Model FTR-K1TBK(#1)W-HT all 105 C 17 A, 277 V ac, resistive, 50,000 cycles Double stable: Form C: Model FTR-K1L(D)CK(#3)W all 85 C 16 A, 250 V ac, Resistive, 50,000 cycles 16 A, 24 V dc, Resistive, 50,000 cycles TV-5, 120 V ac, 25,000 cycles, (NO contact only) Form A: Model FTR-K1L(D)AK(#3)T all 85 C 16 A, 250 V ac, Resistive, 50,000 cycles 16 A, 24 V dc, Resistive, 50,000 cycles TV-5, 120 V ac, 25,000 cycles *

7 File E63614 Vol. 1 Sec. 25 Page 2B Issued: and Report New: ELECTRICAL RATINGS: (Cont d.) Coil: (#1) Range V dc. (400 mw, General Sensitivity A or K) (#2) Range 5-48 V dc (250 mw, High Sensitivity D or L) (#3) Range 5-24 V dc (1 coil: 400 mw, 2 coils: 600 mw) ELEVATED AMBIENT RATINGS: The elevated ambient rating depends on the current rating and is noted under the Electrical Ratings. ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE S USE): This component has been judged on the basis of the required spacings in the Standard for Industrial Control Equipment, UL 508, Seventeenth Edition, which would cover the component itself if, submitted for unrestricted Listing. Use - For use only in (or with) complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc.

8 File E63614 Vol. 1 Sec. 25 Page 3 Issued: NOMENCLATURE (Single stable): FTR-K1 A K 005 W -LB KS HT 01 I II III IV V VI VII VIII IX I. Indicates types number, with or without prefix FTR-. FTR-K1 - PCB terminal type FTR-K1T Tab terminal type II. Indicates Contact configuration. A - 1 Form A Pin terminals or 1 Form A Tab terminal vertical connect C - 1 Form C J 1 Form A, Tab terminal horizontal connect B 1 Form B, Tab terminal vertical connect (only available for FTR-K1T models) III. Indicates Coil Sensibility / enclosure. K General L - High Sensitive IV. Indicates coil rated voltage. 005 through through 48 V dc (High Sensitivity) 005 through through 110 V dc (General Sensitivity) V. Indicates contact material or TV Type. W Silver-tin oxide and Copper base overlaid with silver-tin oxide. T - TV rated, in addition to general coil Sensibility. (Same material as W) E Silver nickel (Ag: 90% Ni: 10%)and copper base overlaid with silver nickel. VI. Indicates contact rated / terminal pitch. None 16 A / 5.0 mm or 17A /Tab terminal LB - 10 A / 5.0 mm MA - 12 or 16 A / 3.5 mm MB - 12 or 16 A / 5 mm LA - 10 A / 3.5 mm VII. Indicates High inrush current (TV-8) / Enclosure. None - Standard KS - TV-8 rated type, in addition to TV type T and general coil Sensitivity (without suffix LA, LB, MA, MB) KW - Flux sealed type, in addition to general coil Sensitivity (without suffix LA, LB, MA, MB)

9 File E63614 Vol. 1 Sec. 25 Page 3A Issued: NOMENCLATURE (Single stable): (Cont d.) VIII. Indicates suitability for use at high temperatures. Blank Suitable for use in maximum ambient temperatures of 85 C HT - Suitable for use in an ambient temperature of 105 C (except the model with suffix KS and KW is also suitable for use in an ambient temperature of 105 C withot suffix HT) IX. Indicates minor construction variation. -01 through 99. Additional two digits used for special, minor variation of construction as below. A) Variation of coil resistance. B) Variation of pickup voltage, non-pick up voltage, dropout voltage or hold voltage. C) Variation of operate or release time. D) Variation of dielectric strength.

10 File E63614 Vol. 1 Sec. 25 Page 3B Issued: and Report New: NOMENCLATURE (Double stable): FTR-K1 L D C K 005 W -01 I II III IV V VI VII VIII I. Indicates types number, with or without prefix FTR-. II. Indicates Operating function. L - Double stable type III. Indicates Coil type. None 1 coil D - 2 coils IV. Indicates Coil power. K - Standard V. Indicates Coil rated Voltage. 005 through through 24 V dc VI. Indicates Contact material. W T Silver-tin oxide and Copper base overlaid with silver-tin oxide. (Form C only) - Same material as W. (Form A only) VII. Indicates Minor construction variation. -01 through Additional two digits used for special, minor variation of construction as below. A) Variation of coil resistance. B) Variation of pickup voltage, non-pick up voltage, dropout voltage or hold voltage. C) Variation of operate or release time. D) Variation of dielectric strength.

11 File E63614 Vol. 1 Sec. 25 Page 4 Issued: * Conditions of Acceptability: 1. A suitable enclosure should be provided for these devices in the end-product. 2. The relay terminals are not suitable for field wiring. The relay terminals are to be factory wired only and the suitability of the connection (including spacings between factory connectors) shall be determined. 3. These devices should be used within its Recognized rating as specified above. 4. Model FTR-K1CK012W was tested to cover the 20 A, 277 V ac resistive rating at 75 C for all FTR-K1CA(#1)W, FTR-K1CK(#1)W, FTR-K1AA(#1)T, and FTR-K1AK(#1)T models. The test was conducted in a 4.5 by 2.5 by 2 in (114 by 63.5 by 51 mm) single-gang junction box. A temperature test in the end product should be considered if using these devices at 20 A in a smaller enclosure in a 75 C ambient. 5. Dust cover has not been evaluated as an insulating barrier. Consideration should be given in the end-use application with regards to spacing requirements to uninsulated live parts.

12 File E63614 Vol. 1 Sec. 25 Page 5 Issued: CONSTRUCTION DETAILS: USR Indicates these devices were evaluated in accordance with the requirements in the UL Standard for Safety of Industrial Control Equipment, UL 508. CNR Indicates FTR-K1L series were evaluated in accordance with the requirements in the Canadian Standard, CAN/CSA C22.2 No.14-10, Industrial Control Equipment, 11th Edition with revisions through April 1, These devices employ a Class F insulation system. Model Differences The only difference between -MA and -MB is the pitch of the terminals (-MA: 3.5 mm, -MB: 5.0 mm). All other construction and materials used are identical to each other. See ILL. 7 for more details. The product shall be constructed in accordance with the following description: 1. Spacings - Spacings of not less than 1/8 inch, 3.2 mm, through-air and 1/4 inch, 6.4 mm, measured over-surface of insulating materials, including printed wiring boards, are maintained between any uninsulated live part and an uninsulated live part of opposite polarity, uninsulated grounded part other than the enclosure or exposed metal part. 2. Corrosion Protection - All parts are of corrosion resistant material or are plated or painted. 3. Marking Ink-stamped label, recognized trade name and model number.

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL

File E Project 92ME February 6, 1992 REPORT COMPONENT - POWER SUPPLIES. For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL File E135493 Project 92ME10175 February 6, 1992 REPORT on COMPONENT - POWER SUPPLIES For Use In INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL Vicor Corp. Andover, MA Copyright 1992 Underwriters

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT

File E Project 07CA Issued: August 29, 2007 Revised: June 22, 2015 REPORT *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT File E132002 Project 07CA41555 Issued: August 29, 2007 Revised: June 22, 2015 REPORT On *COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT *Copyright 2015 UL LLC Astec International Ltd. Kowloon,

More information

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety.

Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. File E171806 Project 04CA46856 October 28, 2004 REPORT on MANUAL MOTOR CONTROLLERS Sontheimer Elektroschaltgerate GmbH Nuremberg, Germany Copyright 1998 Underwriters Laboratories Inc. Underwriters Laboratories

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG DF CP R&D V 3 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional

More information

File E Vol 1 Auth. Page 1 Issued: Revised: Manufacturer: SEE ADDENDUM FOR MANUFACTURER LOCATIONS

File E Vol 1 Auth. Page 1 Issued: Revised: Manufacturer: SEE ADDENDUM FOR MANUFACTURER LOCATIONS File E214129 Vol 1 Auth. Page 1 Issued: 2001-02-27 Revised: 2017-05-25 FOLLOW-UP SERVICE PROCEDURE (TYPE R) COMPONENT - OPTICAL ISOLATORS (FPQU2,FPQU8) Manufacturer: SEE ADDENDUM FOR MANUFACTURER LOCATIONS

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1271882 Master Contract: 165071 Project: 2429855 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention: Mr. Michael

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 2049843 (LR 12730-263) Master Contract: 165071 Project: 2460955 Issued to: Siemens AG I IA CE CP PRM SR Werner-von-Siemens-Strasse 48 Amberg, 92220 Germany Attention:

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

Procedure And/Or Report Material

Procedure And/Or Report Material MR. MILOS PENICKA SIEMENS S A DE C V FCA GUAD CAMINO A LA TIJERA 1 KM 3.5 CARRET GUAD-MORELIA Date: 2008/09/04 45640 TLAJOMULCO DE ZUNIGA Subscriber: 284491003 JAL MEXICO PartySite: 44050 File No: E248638

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC PCB Relay R G5LE-E/-G Single-pole 0A35VDC 0.8mm Contact Gap Power Relay : Single-pole 6A250VAC Power Relay : G5LE-E Sub-miniature 'sugar cube ' relay with universal terminal footprint. UL class-f coil

More information

5 mm contact pin pitch PCB or 95 series sockets

5 mm contact pin pitch PCB or 95 series sockets 1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket

More information

Type List. Standard Type. High Power Type. Designation (provided with) Terminal style Contact form Contact gap

Type List. Standard Type. High Power Type. Designation (provided with) Terminal style Contact form Contact gap Features 8A/1 miniature PCB Power Relay. Large contact gap : 2mm/. High dielectric strength and comply with IEC 16950. Epoxy seal type and sealed flux free are both available. Design for UPS and power

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

Type List. Standard Type. High Power Type

Type List. Standard Type. High Power Type Features 8A/1 miniature PCB Power Relay. Large contact gap : 2mm/. High dielectric strength and comply with IEC 16950. Epoxy seal type and sealed flux free are both available. Design for UPS and power

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

Type MTS Miniature Test Switches

Type MTS Miniature Test Switches Type MTS Miniature Test Switches o o o o Compact and versatile Front- and back-connected styles Safe, durable, rugged and reliable Recognized by CUL & UL DESCRIPTION In many panelboard, switchgear, metering,

More information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text Surface-Mounting Signal Relay G6K Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

File E87247 Project 07CA July 19, 2008 REPORT UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT

File E87247 Project 07CA July 19, 2008 REPORT UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT File E87247 Project 07CA43188 July 19, 2008 REPORT ON UNINTERRUPTIBLE POWER SUPPLY EQUIPMENT Copyright 2008 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company

More information

Table of Contents. HCC Contactor Nomenclature

Table of Contents. HCC Contactor Nomenclature Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose

More information

Heavy Duty DC Contactors for Power Distribution Centres

Heavy Duty DC Contactors for Power Distribution Centres for Power Distribution Centres SW260, SW500, SW560, SW600, SW800, SW1000 & SW1500 TYPES SW260A SW800A SW1500A DC Contactors for Power Distribution Centres The Range SW260(A) SW500(A) SW560(A) SW600(A)

More information

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp 48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp E13224 The 48 series is a contactor with a 4 normally open, double make contacts rated up to 3HP. It uses a solenoid type moving core design

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Arc barrier equipped High dielectric strength (2,000 VAC) Long dependable service life assured by AgCdO contacts Choose models with single or bifurcated contacts, LED indicator, diode

More information

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment PCB Relay Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment High sensitivity can be driven by digital circuits. Horizontal design allows use in /2-inch PCB racks.

More information

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified POWER & ACTUATION ENCLOSED MOTOR PROTECTION CIRCUIT BREAKER & CONTACTOR ASSEMBLIES c3controls Series Enclosed Direct-On-Line (DOL) Starters come with all the features and benefits of our Series 330 Motor

More information

General Specifications

General Specifications Series JW High Inrush 0 & 6 Amp Rockers Touch Tilt Rockers Toggles Slides Rotaries Programmable Illuminated P Pushbuttons Supplement Accessories Indicators Tactiles Keylocks General Specifications Electrical

More information

DIM. A (+ 0,05 0,51) .437 ±.020 (11,10 ± 0,51) DIM. F ±.015 (0,38) INTEGRAL ASSEMBLY NUT, DO NOT REMOVE

DIM. A (+ 0,05 0,51) .437 ±.020 (11,10 ± 0,51) DIM. F ±.015 (0,38) INTEGRAL ASSEMBLY NUT, DO NOT REMOVE Multi-Deck SERIES,, and " Diameter, Amp, Standard, Military SR0 FEATURES Rugged Construction Insures Switch Operation for the Life of Your Equipment Many Circuitry Options MIL Qualified Versions MIL-S-/0

More information

Features. Type List A

Features. Type List A Type List Terminal style PCB terminal A Contact form (SPNC) (SPNC) eatures Heavy duty 30A general purpose Power Relays. UL/CUL (UL 508 & 873), VDE safety approvals. Optional for open frame, dust cover,

More information

LISTING REPORT/INSPECTION PROCEDURE

LISTING REPORT/INSPECTION PROCEDURE LISTING REPORT/INSPECTION PROCEDURE 291 Fairfield Avenue, Fairfield, NJ 07004 USA (973) 575-5252 File No. E1052012, Section 1 Issued: December 16, 2008 A representative sample of the product covered by

More information

40 Series - Miniature PCB relays A. Features

40 Series - Miniature PCB relays A. Features 1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole

More information

Ordering Information. Text PCB Power Relay G5LE

Ordering Information. Text PCB Power Relay G5LE A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Type Terminal Coil Contact form Model

Type Terminal Coil Contact form Model General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode

More information

Features. Type List 832A

Features. Type List 832A Type List Terminal style PCB terminal A Contact form (SPNC) (SPNC) Insulation eatures Heavy duty 30A general purpose Power Relays. UL/CUL (UL 508 & 873), VDE safety approvals. Optional for open frame,

More information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED-CASE AND CIRCUIT BREAKER ENCLOSURES

More information

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive

More information

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ

File E Project 02ME CORD CONNECTED CLASS 2 POWER UNITS. Globtek Inc. Northvale, NJ File E132594 Project 02ME17432 2003-02-09 REPORT on CORD CONNECTED CLASS 2 POWER UNITS Globtek Inc. Northvale, NJ Copyright 2003 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes

More information

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes EPIC Hermetic Sealed DC and AC Contactor - 150+ Power Switching RoHS Compliant, all date codes File E320908 All contact ratings and coil versions may not be UL recognized. Contact GIGAVAC for a copy of

More information

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Sheet 1 of 6 Order Number Serial Number PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Issue Date Level A 22/10/02 Initial issue. Summary of changes Due to RMS continuous product improvement policy

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

Pluggable interface relays RT, PT and MT range

Pluggable interface relays RT, PT and MT range Content Pluggable interface relays RT, PT, MT Benefits and advantages, approvals... 190 Ordering details... 191 Technical data... 194 Circuit diagrams... 19 Dimensional drawings... 19 189 Benefits and

More information

High barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E 1512 E47705 Report Reference E4770519970821 15OCTOBER12 Issued to: SIEMENS AG DF CP R&D V 3 WERNERVONSIEMENSSTRASSE 48 9 AMBERG GERMANY This is to certify that representative samples of MOTOR CONTROLLERS,

More information

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT

File E Project 01ME June 15, 2001 REPORT POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT File E170507 Project 01ME11924 June 15, 2001 REPORT ON POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Globtek Inc. Northvale, NJ Copyright 2001 Underwriters Laboratories

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction

7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction 7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Note:7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data

More information

Signal Signal Relays. Potter & Brumfield. R10 Series Relay

Signal Signal Relays. Potter & Brumfield. R10 Series Relay R Series Relay n 1 through 8 form C (CO) contact arrangement n Broad range of coil options provides sensitivity ranging from 25 to 750mW n Various contacts switch from dry circuit to 7.5 amps n Many mounting

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

Selection Guide 2-4 K1 5-7 K K4/K K K K K K K K43/K K45/K K

Selection Guide 2-4 K1 5-7 K K4/K K K K K K K K43/K K45/K K Contents Page Selection Guide 2-4 K 5-7 K3 8- K4/K5-3 K4T/K5T 3A-3C K6 4-6 K7 7-9 K32 22-23 K34 24-26 K4 27-29 K42 3-32 K43/K44 33-35 K45/K46 36-38 K49 39-4 K5 47W (type K52) 4A-4B 4C-4D Sockets 42 Glossary

More information

Type SJK Test Switches

Type SJK Test Switches Type SJK Test Switches No-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together DESCRIPTION STATES

More information

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F 8H Type List 8H Terminal style Contact form Features Miniature PCB Power Relays A 2VAC. High CTI 2 material or product comply with IEC 33-1 are available. UL Insulation Class F. VDE, UL/CUL, TUV, CSA/CUS

More information

General Purpose Relays Industrial Relays. Power Relay RM 2/3/7

General Purpose Relays Industrial Relays. Power Relay RM 2/3/7 Power Relay RM 2/3/7 n 2/3 pole 10/16A, 2 form C (CO) or 3 form C (CO) contacts n Switching capacity up to 6000VA n DC or AC coil n Mechanical indicator n Push-to-test button n Plug-in version, PCB terminals,

More information

KS3 Revision. 8J Magnets and Electromagnets

KS3 Revision. 8J Magnets and Electromagnets KS3 Revision 8J Magnets and Electromagnets 1 of 29 Boardworks Ltd 2007 Contents 8J Magnets and Electromagnets Magnetic materials Magnetic fields Electromagnets Summary activities 2 of 29 Boardworks Ltd

More information

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC PCB Relay Subminiature Relay that Switches up to 5 A Subminiature: 20 10 10 mm (L W H). Low power consumption: 200 mw. Unique moving loop armature reduces relay size, magnetic interference, and contact

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR: SERIES 782XBX/XDX DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FEATURES FLAG INDICATOR: L.E.D. STATUS LAMP: PUSH BUTTON: LOCK-DOWN DOOR: FINGER-GRIP COVER: I.D. TAG/WRITE LABEL: COVER ADAPTERS: BENEFITS

More information

Features. Designation Enlarge spacing type Dust cover Flux tight Flanged cover

Features. Designation Enlarge spacing type Dust cover Flux tight Flanged cover Features Heavy duty A 2VAC, 2A 2VAC power type. AC & DC coils are both available. PCB terals and quick teral types. Optional for special large contact gap 3.0mm version. SPNO-ST & DPNO-ST contact configuration.

More information

INTERPLANT STANDARD - STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION FOR MAGNETIC OVER- CURRENT RELAYS FOR ac AND dc MOTORS PROTECTION UP TO 650 V (FIRST REVISION) CORRESPONDING INDIAN STANDARD DOES NOT EXIST IPSS:1-04-008-11

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that

More information

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes Patent Pending File E320908 All contact ratings and coil versions may not be UL recognized.

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS 1 Module 2 CONTROL SYSTEM COMPONENTS Lecture - 4 RELAYS Shameer A Koya Introduction Relays are generally used to accept information from some form of sensing device and convert it into proper power level,

More information

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0 General Purpose Relay LY Arc barrier equipped. High dielectric strength (2,000 VAC). Long dependable service life assured by Ag-Alloy contacts. Choose models with single or bifurcated contacts, LED indicator,

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

44 SERIES. PCB/Plug-in relays from 6 to 10 A

44 SERIES. PCB/Plug-in relays from 6 to 10 A 44 PCB/Plug-in relays from 6 to 10 44 2 CO power relays with high separation between adjacent contacts Direct PCB or socket mount Type 44.52 -- 2 CO 6 (5 mm pin pitch) Type -- 2 CO 10 (5 mm pin pitch)

More information

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1588199 (LR 12730-233) Master Contract: 165071 Project: 1588199 Date Issued: 2004/11/03 Issued to: Siemens AG A&D CD CC TS2 Werner-von-Siemens-Strasse 48 Amberg,

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3

table of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3 table of contents Switches Quick Guide to Switches....................................... J2-J3 Push Switches.............................................. J4-J7 Single Pole ON-OFF.......................................

More information

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

Limit Switches. Reference Information. Proper Application of Limit Switches General Information. Definition of Limit Switch Terms.

Limit Switches. Reference Information. Proper Application of Limit Switches General Information. Definition of Limit Switch Terms. Reference Proper Application of General switches are used to convert a mechanical motion into an electrical control signal. The mechanical motion is usually in the form of a cam, a machine component or

More information

T75S5D Product Details

T75S5D Product Details T75S5D112-12 Product Details Industrial Relays (General Purpose) Converted to EU RoHS but not ELV Compliant (Statement of Compliance) T75S5D112-12 TE Internal Number: 1393223-3 Active Product Highlights:

More information

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Sheet 1 of 7 Order Number Serial Number PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY Issue Date Level C /04/1996 Initial issue. Summary of changes Due to RMS continuous product improvement

More information

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.

HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits. HA Hinged Armature Auxiliary Hinged armature auxiliary relay to perform auxiliary functions in and circuits. eatures and Benefits Molded case with 4 mounting options Drawout case available Applications

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Model Number Structure

Model Number Structure Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive

More information

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472 Data sheet 2-way solenoid valves with Clip-on coils for neutral liquids and gases January 200 DKACV.PD.200.K.22 520B472 2 DKACV.PD.200.K.22 Danfoss A/S 0-200 Contents 2-way solenoid valves with Clip-on

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

Scheda prodotto Relè Series B

Scheda prodotto Relè Series B Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where

More information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL. High Load Relay for Smart Junction Box TL RELAYS High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight New 14.4.7 11.433 1.3 FEATURES Large capacity switching

More information