Table of Contents. HCC Contactor Nomenclature
|
|
- Arabella Joseph
- 6 years ago
- Views:
Transcription
1 Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose Contactors... Page 0 HCC SERIES: Pole Definite Purpose Contactors... Page 0 90 HCK SERIES: Motor Run Capacitors... Page 8 HCS SERIES: Motor Start Capacitors... Page 8 HCR SERIES: Type Potential Start Relay... Page 9 SPNC HCR SERIES: Type General Purpose Switching Relay... Page SPNO & SPDT HCR SERIES: Type General Purpose Switching Relay... Page 11 DPNO, DPDT, & SPDT HCT SERIES: Wire Lead & Quick Connect Transformers... Page 1 0 VA & VA (Compact) HCT SERIES: Wire Lead & Quick Connect Transformers... Page 1 VA & 0 VA HCT SERIES: Wire Lead & Quick Connect Transformers... Page 1 7VA HCC Contactor Nomenclature HCC 1X Q 01 AA 0 C SERIES: HCC Hartland Controls Contactor PACKAGING: Factory Bulk Pack Y Individual Box Pack POLE FORM: 1X 1PNO with shunt X PNO X PNO 1N 1PNO without shunt X PNO E form X NO, 1 form Y NC COIL VOLTAGE: Q V 77 T H U 08/ CONTACT RATING: TERMINATION: FOR 1 & POLE A A # combo screw with quad QC (0 ) C Y # combo screw with dual QC (0 ) BB Same as AA with sems plate C G #1 lug with dual QC () G G # 1 lug with quad QC ( ) C J #1 lug with dual QC (00 ) * Contact Hartland Controls for additional options C J #1 1 lug with dual QC (790 ) CUSTOMER IDENTIFICATION: (0 999) Optional customer specific designation assigned by Hartland Controls to specify significant variation from the standard construction. OPTIONAL COVER: C Indicates the addition of a cover for 1 & Pole contactors up to
2 HC Auxiliary Switches Available Auxiliary Switches for & Pole Contactors (0 ) Description Single unit interlock configuration. One on each side max. of two Single unit interlock configuration. One on each side max. of two Contact Configuration 1 NO / 1 NC (break before make) 1 NO / 1 NC (break before make) Terminatio n Part Number. 0" quick connects HCC1Z00VQ # screw terminals HCC1Z00VS SPDT ciruit. One switch per side. SPDT. 0" quick connects HCC1C0VQ SPDT circuit. Two switches per side. ( ) SPDT. 0" quick connects HCCC0VQ Contact Rating Single Circuit 1 NO / 1 NC Contact Rating SPDT Rating 00 Amperes Break Amperes Make 1 7 Amperes Continuous A, 1/ HP, 1 or 0 1/A, 1 VDC 1/A, 0 VDC A, on lamp load 1 NO / 1 NC quick connects 1 NO / 1 NC screw terminals One SPDT switch per side Two SPDT switches per side Terminations Standard on 0 Optional on 0 lug 0/0 lug 7/90 lug # combination phillips, slotted & /1 hex head with #1 washer # sems screw with pressure plate AWG Cu/Al 1 AWG Cu/Al 1 1 AWG Cu/Al Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199! 1
3 HCC SERIES Definite Purpose Contactor HC 1 & POLE 0! 1 Pole NO with or without shunt! Pole NO! Silver Cadmium Oxide Contacts! UL 08 File No. E70 Class NLDX, NLDX8! Semko/CE File No. EN 0971:001! CSA File No. (1) Class 11 0 / 11 8 Partial Listing of Available 1 & Pole Contactors Rating 0 Number of Poles V HCC1XQ00AA HCCXQ00AA HCC1XQ01AA HCCXQ01AA HCC1XQ0AA HCCXQ0AA HCC1XQ0GG HCCXQ0GG V HCC1XT00AA HCCXT00AA HCC1XT01AA HCCXT01AA HCC1XT0AA HCCXT0AA HCC1XT0GG HCCXT0GG 08/V HCC1XU00AA HCCXU00AA HCC1XU01AA HCCXU01AA HCC1XU0AA HCCXU0AA HCC1XU0GG HCCXU0GG 77V HCC1XV00AA HCCXV00AA HCC1XV01AA HCCXV01AA HCC1XV0AA HCCXV0AA HCC1XV0GG HCCXV0GG INITIAL DIELECTRIC STRENGTH Between Contacts & s:,00 Between Poles:,00 (includes shunt) Between Open Contacts:,00 (no shunt) ARC COVER Optional on 0 Standard on INSULATION SYSTEM 1 o C Class B TEMPERATURE RANGE o C to + o C o F to + o F UNIT WEIGHT 1 Pole. lb Pole. lb POWER POLE TERMINATIONS # screw or box lug WIRE SIZE # screw 18* Box lug 1 *must use ring terminal RECOMMENDED TIGHTENING TORQUE # screw in. lbs Box lug in. lbs QUICK CONNECTS terminals Power terminals Dual:.0 QC 1 Pole: Quad.0 QC Pole: Dual or Quad.0 QC Rating 1 Pole Contactors Pole Contactors Nominal 08/ 77 08/ 77 Nominal Resistance Ohms Mazimum Pick Up Minimum Drop Out Nominal Inrush 0 Hz Nominal Inrush 0 Hz Nominal Sealed 0 Hz Nominal Sealed 0 Hz Maximum Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
4 HC Definite Purpose Contactor HCC SERIES 0 1 & POLE Electrical Rating Full Load Amps Resistive 00 Locked Rotor Locked Rotor Locked Rotor / Pole Contactors Pole Contactors Pole Dimensions (Inches) Maximum Horsepower Single Phase Pole Dimensions (Inches) Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
5 HCC SERIES Definite Purpose Contactor HC & POLE 0! Pole NO! Pole NO! Silver Cadmium Oxide Contacts! UL 08 File No. E70 Class NLDX, NLDX8! Semko/CE File No. EN 0971:001! CSA File No. (1) Class 11 0 / 11 8! Optional Auxiliary Switches located on page 1. Partial Listing of Available & Pole Contactors Number V Rating of Poles 0 HCCXQ00CY HCCXQ01CY HCCXQ0CY HCCXQ0CY HCCXQ0CG HCCXQ0CG V HCCXT00C Y HCCXT01C Y HCCXT0CY HCCXT0CY HCCXT0CG HCCXT0CG 08/V HCCXU00CY HCCXU01CY HCCXU0CY HCCXU0CY HCCXU0CG HCCXU0CG 77V HCCXV00CY HCCXV01CY HCCXV0CY HCCXV0CY HCCXV0CG HCCXV0CG INITIAL DIELECTRIC STRENGTH Between Contacts & s:,00 Between Poles:,00 Between Open Contacts:,00 ARC COVER Standard INSULATION SYSTEM 1 o C Class B TEMPERATURE RANGE o C to + o C o F to + o F UNIT WEIGHT Pole 1 lb Pole 1. lbs POWER POLE TERMINATIONS # screw or box lug WIRE SIZE # screw 18* Box lug 1 *must use ring terminal RECOMMENDED TIGHTENING TORQUE # screw in. lbs Box lug in. lbs QUICK CONNECTS terminals Dual:.0 QC or # screw/.0 QC Power terminals Dual.0 QC Rating Pole Contactors Pole Contactors Nominal / 77 Nominal Resistance Ohms Maximum Pick Up Minimum Drop Out Nominal Inrush 0 Hz Nominal Inrush 0 Hz Nominal Sealed 0 Hz Nominal Sealed 0 Hz Maximum Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
6 HC Definite Purpose Contactor HCC SERIES 0 & POLE Electrical Rating Full Load Amps Resistive 00 Pole Dimensions (Inches) Locked Rotor /77 Locked Rotor Locked Rotor 00 Pole Contactors Pole Contactors Maximum Horsepower Single Three Phase Phase /77 /00 /77 00 /77 00 /77 00 /77 / Pole Dimensions (Inches) Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
7 HCC SERIES Definite Purpose Contactor HC POLE 0 90! Pole NO! Silver Cadmium Oxide Contacts! UL 08 File No. E70 Class NLDX, NLDX8! CSA File No. (1) Class 11 0 / 11 8 Partial Listing of Available 0 90 Contactors Rating Number of Poles V V 0 HCCXQ0CJ HCCXT0C J 0 HCCXQ0CJ HCCXT0C J 7 HCCXQ07CJ HCCXT07C J 90 HCCXQ09CJ HCCXT09C J 08/V HCCXU0CJ HCCXU0CJ HCCXU07CJ HCCXU09CJ 77V HCCXV0CJ HCCXV0CJ HCCXV07CJ HCCXV09CJ INITIAL DIELECTRIC STRENGTH Between Contacts & s:,00 Between Poles:,00 Between Open Contacts:,00 ARC COVER Standard INSULATION SYSTEM 1 o C Class B TEMPERATURE RANGE o C to + o C o F to + o F UNIT WEIGHT 0 0 lbs 7 90 lbs POWER POLE TERMINATIONS Aluminum box lug WIRE SIZE 0/0 Box Lug 1 7/90 Box Lug 11 RECOMMENDED TIGHTENING TORQUE Box lug 0 in. lbs QUICK CONNECTS terminals Dual:.0 QC or # screw/.0 QC Power terminals Dual.0 QC Rating 00 Contactors 790 Contactors Nominal / 77 Nominal Resistance Ohms Maximum Pick Up Minimum Drop Out Nominal Inrush 0 Hz Nominal Inrush 0 Hz Nominal Sealed 0 Hz Nominal Sealed 0 Hz Maximum Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
8 HC Definite Purpose Contactor HCC SERIES 0 90 POLE Electrical Rating Full Load Amps Resistive 00 Locked Rotor /77 Locked Rotor Locked Rotor 00 Pole Contactors Maximum Horsepower Single Three Phase Phase 1/0 00/ / 00/ / 00/ / 00/ Dimensions (Inches) Dimensions (Inches) Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199! 7
9 Motor Run & Start Capacitors HC HCK SERIES Motor Run Capacitors! Single and dual rated values! Round or oval case options! Aluminum oil filled construction! Plastic dry construction! Designed & manufactured in accordance with UL 8 and EIA standard RS! Custom configurations available! Consult www. hartlandcontrols.com for standard models Technical Data Rated 70 and (contact factory for alternative voltage) Capacitance Tolerance +/% Operating Temperature o C to 70 o C Leakage Current ua max. Dissipation Factor 0.1% max. Frequency 0/0 Hz Internal Protection UL recognized internal protection Operating Life 0,000 hours with 9% survival bridge capable of interrupting Terminations.0 x.0 QC blades of up to K amp Case Material / Finish Unpainted aluminum case, steel cover HCS SERIES Motor Start Capacitors! Moisture & oil resistant plastic case! Designed & manufactured in accordance with EIA standard RS! EIA Type 1 & available! Custom configurations available! Consult www. hartlandcontrols.com for standard models Technical Data Capacitance Operating Frequency Ambient Temperature Terminations 1 1 mf 1 0/0 Hz o C / + o C.0 x.0: QC blades 8 Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
10 HC SPNC Start Relay HCR SERIES! Multiple mounting positions!.0 QC or 8 screw terminals! Class B insulation system! Consult Hartland Controls for UL information HCR Nomenclature HCR 1 C 07 A 000 Series Packaging Relay Type Mounting Position Factory Six positions Hartland Bulk Box available. See Controls Y Individual below for more Relay Pack Box details. *Consult factory for 0 Amp applications. Bracket Type C Panel mount with tab D Panel mount without tab Rating & Calibration See opposite page for more details. Terminatio n A.0" QC B 8 screw Customer Identification Optional customer number assigned by Hartland Controls CONTACT DATA Arrangement Contact Material Contact Rating Mechanical Life Expectancy Electrical Life Expectancy SPNC Silver Cadmium Oxide Alloy A (break only) 0 1A (make & break) 0 1,000,000 operations 0,000 cycles breaking rated load SPECIFICATIONS Dielectric Strength (minimum between live parts and exposed noncurrent carrying metal parts) Current Draw VA Frequency 0 / 0 Hz Unit Weight. lb Dimensions (Inches) Mounting Positions Relays are calibrated in specified positions voltages may vary if relay is mounted in alternate position. 1 Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199! 9
11 HCR SERIES SPNO & SPDT General Purpose Switching Relay HC! SPNO, SPNC, SPDT, 1 NO & 1 NC switching configurations! Class B insulation system!.0 QC terminals! Multipositional mounting! UL 08 File No. E70 Class NLDX, DNLDX8 Partial Listing of Available HCR Relays : 08/ SPNO HCR1AQ1A B HCR1AT1A B HCR1AU1A B SPDT HCR1CQ1A B HCR1CT1A B HCR1CU1A B 1NO & 1NC HCR1ZQ1A B HCR1ZT1A B HCR1ZU1A B HCR Nomenclature HCR 1X Q I AB 000 Series Hartland Controls Relay Packaging Factory Bulk Box Y Individual Pack Box CONTACT DATA Arrangement Contact Material Power Rating SPSTNO only Pilot Duty Rating Relay Type Pole Form 1A SPNO 1B SPNC 1C SPDT 1Z 1 NO & 1 NC / Relay Performance ID Letter Q T U 08/ V 77 SPNO, SPNC, SPDT, 1NO &1NC Silver Cadmium Oxide Alloy 1 0 LRA 18 Amps LRA 18 Amps /77 AC Amps 77 Amps, Nominal Pick Up Drop Out / 17 8 Q T 0 U 0 Dimensions (Inches) Maximum. Contact Rating 1 Power Rated Pilot Duty Mounting AB /" Panel AC /8" Panel Customer Identification Optional customer number assigned by Hartland Controls SPECIFICATIONS Temperature Range AC to +1 o C Unit Weight.19 lb Power Pole Terminations.0 QC Termination.0 QC Mechanical Life Expectancy 1 million operations Electrical Life Expectancy 0,000 operations resistive 0,000 operations inductive COIL Nominal Power DC. W AC.0 VA Nominal Sealed VA Resistance (maximum Ohms Inrush VA 7,00 7, max Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
12 HC SPNO, SPDT, DPNO, & DPDT General Purpose Switching Relay HCR SERIES! SPNO, SPDT, DPNO & DPDT switching configurations! Class B insulation system!.0 QC terminals! Multipositional mounting! UL 08 File NO. E70 Class NLDX, NLDX8 Partial Listing of Available HCR Relays : SPNO SPDT DPNO DPDT Dimensions (Inches) 08/ HCR1AQ1A A HCR1AT1A A HCR1AU1A A HCR1CQ1A A HCR1CT1A A HCR1CU1A A HCRAQ1A A HCRAT1A A HCRAU1A A HCRCQ1A A HCRCT1A A HCRCU1A A HCR Nomenclature HCR A Q I AA 000 Series Hartland Controls Relay Packaging Factory Bulk Box Y Individual Pack Box CONTACT DATA Arrangement Contact Material Power Rating Pilot Duty Rating Relay Type Pole Form A DPNO C DPDT 1C SPDT 1A SPNO 1B SPNC Q T U 08/ V 77 SPNO, SPNC, SPDT, DPNO, DPDT Silver Cadmium Oxide Alloy / HP 1/0 1 0 LRA 1A 1 LRA 1A 0/77 18 LRA 1.A 1 LRA 00 1/ HP 1/0 1 1/0/ Amp 77 / Relay Performance Nominal Pick Up Drop Out ID Letter Q T U 08/ 17 8 Contact Rating 1 Power Rated Pilot Duty Mounting AA Bracket mounting with.0" QC SPECIFICATIONS Temperature Range Unit Weight Power Pole Terminations Termination Mechanical Life Expectancy Electrical Life Expectancy Customer Identification Optional customer number assigned by Hartland Controls to +1 o C.8 lb.0 x.0 QC.0 QC 1 million operations 0,000 operations resistive 0,000 operations inductive COIL Nominal Power DC. W AC.0 VA Maximum Nominal Sealed VA Resistance (maximum Ohms Inrush VA , , Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199! 11
13 HCT SERIES TRANSFORMERS 0 VA & VA (Compact) Wire Lead & Quick Connect HC! UL/CUL recognized File No. E7, Guide No. XOKV! Inherently limited! No secondary fusing required! Consult Hartland Controls for specific requirements not shown in catalog. WIRE SIZE All leads are 18 AWG stranded / insulation thickness. Standard parts have1 total length, with 1/ strip. QUICK CONNECT SIZE Standard male quick connect terminals are.0 x.0. FREQUENCY 0/0 HZ INSULATION SYSTEM 1 o C Class B UNIT WEIGHT 0 VA.89 lb VA 1. lbs Partial Listing of Available 0 VA & VA (Compact) Transformers Primary Secondary 0 VA Wire Lead VA Wire Lead 0 VA Quick Connect VA Quick Connect HCT01C0AA01 HCT0C0AA01 HCT01A0AA01 HCT0A0AA01 HCT01C0BB09 HCT0C0BB09 HCT01A0BB09 HCT0A0BB09 77 HCT0C0AA01 HCT0C0AA01 HCT0A0AA01 HCT0A0AA01 HCT0C0BB09 HCT0C0BB09 HCT0A0BB09 HCT0A0BB09 08/ HCT09C0AA01 HCT09A0AA01 HCT09C0BB09 HCT09A0BB09 Primary Lead Features Color ead Length trip Length L " S " Common Black White Red Orange Brown Black/Red Grey 1 1 / 1 /" 1 /" 1 /" 1 /" 1 /" 1/" Secondary Lead Features Color ead Length trip Length L " S " Common Blue Yello w 1 1 / 1/" 1 Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
14 HC 0 VA & VA (Compact) Wire Lead & Quick Connect HCT SERIES TRANSFORMERS 0 VA Wire Lead Models (Inches) VA (Compact) Wire Lead Models (Inches) VA & VA (Compact) Quick Connect Models (Inches). 1.0 A Dim B Dim VA VA A Dim..8.9 B Dim Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199! 1
15 HCT SERIES TRANSFORMERS VA & 0 VA (Compact) Wire Lead & Quick Connect HC! UL/CUL recognized File No. E7, Guide No. XOKV! Inherently limited! No secondary fusing required! Consult Hartland Controls for specific requirements not shown in catalog. WIRE SIZE All leads are 18 AWG stranded / insulation thickness. Standard parts have1 total length, with 1/ strip. QUICK CONNECT SIZE Standard male quick connect terminals are.0 x.0. FREQUENCY 0/0 HZ INSULATION SYSTEM 1 o C Class B UNIT WEIGHT VA 1. lbs 0 VA. lbs Partial Listing of Available 0 VA & VA (Compact) Transformers Primary Secondary 77 /08/ 08/ 80/1 7 VA Wire Lead HCT01E0AA0 HCT0E0AA0 HCT0E0AA0 HCT0E0AA0 HCT0E0AA0 HCT09E0AA0 HCT1E0AA0 HCT78E0AA0 0 VA Wire Lead HCT01D0AA0 HCT0D0AA0 HCT0D0AA0 HCT0D0AA0 HCT0D0AA0 HCT09D0AA0 HCT1D0AA0 HCT78D0AA0 VA Quick Connect 0 VA Quick Connect HCT01E0BB0 HCT01D0BB0 HCT0E0BB0 HCT0D0BB0 HCT0E0BB0 HCT0D0BB0 HCT0E0BB0 HCT0D0BB0 HCT0E0BB0 HCT09E0BB0 HCT09D0BB0 HCT1E0BB0 HCT1D0BB0 HCT78E0BB0 HCT78D0BB0 Primary Lead Features Color ead Length trip Length L " S " Common Black White Red Orange Brown Black/Red Grey 1 / 1 /" 1 /" 1 /" 1 /" 1 /" 1/" 1 Secondary Lead Features Color ead Length trip Length L " S " Common Blue Yello w 1 1 / 1/" 1 Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
16 HC VA & 0 VA Wire Lead & Quick Connect HCT SERIES TRANSFORMERS VA Wire Lead Models (Inches) VA Wire Lead Models (Inches) VA & 0 VA Quick Connect Models (Inches) A Dim B Dim.. VA 0 VA A Dim B Dim Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199! 1
17 HCT SERIES TRANSFORMERS 7 VA Wire Lead & Quick Connect HC! UL/CUL recognized File No. E7, Guide No. XOKV! Noninherently limited! Secondary fusing required! Consult Hartland Controls for specific requirements not shown in catalog. WIRE SIZE All leads are 18 AWG stranded / insulation thickness. Standard parts have1 total length, with 1/ strip. QUICK CONNECT SIZE Standard male quick connect terminals are.0 x.0. FREQUENCY 0/0 HZ INSULATION SYSTEM 1 o C Class B UNIT WEIGHT 7 VA.0 lbs Partial Listing of Available 7 VA Transformers Primary Secondary 7 VA Wire Lead.A Link Fuse 7 VA Quick Connect.A Link Fuse 7 VA Wire Lead.7 Circuit Breaker 7 VA Quick Connect.7 Circuit Breaker HCT01JAF0 HCT0JAF0 HCT01JBB07 HCT0JBB07 HCT01JAF0 HCT0JAF0 HCT01JBB07 HCT0JBB07 77 HCT0JAF0 HCT0JAF0 HCT0JBB07 HCT0JBB07 HCT0JAF0 HCT0JAF0 HCT0JBB07 HCT0JBB07 /08/ /08// HCT0HAF0 HCT08HAF0 HCT0HBB07 HCT08HBB07 HCT0HAF0 HCT08HAF0 HCT0HBB07 HCT08HBB07 08/ 80/1 HCT09JAF0 HCT1JAF0 HCT09JBB07 HCT1JBB07 HCT09JAF0 HCT1JAF0 HCT09JBB07 HCT1JBB07 7 HCT78JAF0 HCT78JBB07 HCT78JAF0 HCT78JBB07 Primary Lead Features Color ead Length trip Length L " S " Common Black White Red Orange Brown Black/Red Grey 1 1 / 1 /" 1 /" 1 /" 1 /" 1 /" 1/" Secondary Lead Features Color ead Length trip Length L " S " Common Blue Yello w 1 1 / 1/" 1 Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199!
18 HC 7 VA Wire Lead & Quick Connect HCT SERIES TRANSFORMERS 7 VA Wire Lead Models (Inches) A Dim B Dim....8 J Series H Series A Dim...7 B Dim VA Quick Connect Models (Inches).00 A Dim B Dim..00. J Series H Series A Dim... B Dim VA & 0 VA Quick Connect Models (Inches).00 A Dim B Dim J Series H Series A Dim B Dim Hartland Controls! 170 Westwood Drive, Sterling, IL 81! ph 81170! fax 8199! 17
30C30 definite purpose contactor
30C 30FLA Definite Purpose Contactor Robust 1-4 Pole Contactor Arc Covers as standard Industry Standard Mounting RoHS Compliant UL File No: E61703 Contact Data Table 1 Arrangements: 1 Form X (SPST-NO-DM)
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationTOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE
TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS P 2 9 1 - RUN CAPACITOR SINGLE P238 MFD PART NUMBER SIGNIFICANCE MFD NON-PCB DIELECTRIC FLUID UL APPROVED CURRENT INTERRUPTER MULTIPLE ELECTRICAL
More information4. Heavy duty Silver Metal Oxide contacts to provide long electrical endurance.
XMC0 Series Definite Purpose Contactors Description Hongfa s Definite Purpose Contactor XMC0 meets the rigorous demands of the HVAC, refrigeration, heating, data processing, welding, elevators, hoist &
More information2. No tools required for snap-on accessories require that make modification quick and easy.
XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1-Pole, 1-Pole+1Shunt, 1-Pole+1NC, 1-Pole+1NO, 2-Pole, 3-Pole,3-Pole+1NC and 3-Pole+1NO,from
More information4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control
. 15 5A Starters A27, B27 Contents Description Page 15 60A Contactors C25................... V5-T-6 25 60A Starters A25, B25................. V5-T-9 15 5A Starters A27, B27 Product Selection.......................
More informationXMC0 Series DEFINITE PURPOSE CONTACTORS
DESCRIPTION American Zettlers XMC0 series of Definite Purpose Contactors are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,
More informationJARD by MARS JARD by MARS
Table of Contents Description Page No. Capacitors Motor Run....................................................................................... J-3 J-5 Motor Start...........................................................................................J-6
More informationSOLDER SHORT SOLDER SCREW
32 Honeywell MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945. CUT-A-WAY V3 MINIATURE BASIC SWITCH GENERAL INFORMATION V3 miniature basic switches feature high electrical capacity
More informationXMC0 Series. Definite Purpose Contactors. Description. Features. Type model nomenclature - Ordering Information
XMC0 Series Definite Purpose Contactors Description HOMER XMC0 series high performance definite purpose contactors (1 pole, 1pole+shunt, pole, pole(optional Auxiliary Contact Blocks or Microswitch Blocks
More informationDATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.
DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN
More information22AF 40AF AF 150AF 225AF 400AF 800AF
Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug
More informationXMC0 Series. Definite Purpose Contactors
Description American Zettler XMC0 series of are electromechanical switching devices designed ideally for the HVAC industry. The most common applications of our contactors are found in refrigeration, air
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More information209 Series. Magnetic Circuit Protectors
29 Series Magnetic Circuit Protectors Introduction 249 Power Selector System Multi-Pole Configurations Operating Characteristics Delay Curves Specifications Decision Tables 73 75 77 79 8 82 85 87 29/29/229/249/279
More informationDefinite Purpose Contactors and Starters
0 40A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview.............................................. 2 Application Description..........................................
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationVacuum Contactors and Starters
Vacuum s and Starters Size 4 Vacuum.1 Product Description....................................... Application Description.................................... Operation...............................................
More information48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp
48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp E13224 The 48 series is a contactor with a 4 normally open, double make contacts rated up to 3HP. It uses a solenoid type moving core design
More informationElectropneumatic Timing Relays Series 7000 Industrial
DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationAF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals
AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.
More informationAR circuit breaker - Hydraulic magnetic,
AR circuit breaker - Hydraulic magnetic, Datasheet railway, small Features Description Small hydraulic magnetic circuit breaker for railway applications to protect electronic equipment and components against
More informationCross reference. Definite Purpose Contactors
Cross reference Definite Purpose Contactors HOMER Tyco/PU Siemens/Furnas GE Culterhammer Schneider/Square D. Honeywell XMC0 100 42/45 CR45 C25 8910 R82 XMCK 100 45 CR45 C25 8910 R82 Contactors HOMER Schneider/TE
More information209/219/229/249/279 Series Magnetic Circuit Protectors
29/29/229/249/279 29/29/229/249/279 Series Magnetic Circuit Protectors Introduction 65 249 Power Selector System 67 Multi-Pole 69 Configurations 7 Operating Characteristics 73 Delay Curves 74 Specifications
More informationBF Series Flasher Thermal flasher circuitry
BF Series Flasher Thermal flasher circuitry Long life 2A load rating @ 115V AC Low cost Small size All units work on AC and DC input voltage 3 terminal configuration 6V to 115V input voltages available
More information24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)
.4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationSwitches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)
SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.
More informationER circuit breaker - Hydraulic magnetic,
ER circuit breaker - Hydraulic magnetic, Datasheet railway, high current and voltage Features Ideal for high current and high voltage applications Precise, temperature independent operation Panel mount
More informationAC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems
AC Leak Freeze AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems Will continue to seal additional Leaks for up to 1 year that meet testing specifications Does not contain
More informationNRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationData Sheet Definite Purpose Contactors Ex9CK Series
Data Sheet Definite Purpose Contactors Ex9CK Series Ex9CK40B0 Ex9CKA10 na.noarkelectric.com NOARK Ex9CK Series Features Ex9CK Series DP Contactors provide high performance with both flexibility and reliability.
More informationMERCURY CONTACTORS & RELAYS
MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More information4.1. Definite Purpose Contactors and Starters. Contents
. Definite Purpose and Starters Product Overview and Starters Definite Purpose and Starters Contents Description Page 20 0A, Compact Single- and Two-Pole C25................................ V5-T- 5 360A,
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationJAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables
JAE Series Magnetic Circuit Protectors Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables 205 207 211 213 216 217 JAE/JRE/JLE Series Hydraulic Magnetic Circuit Protectors
More informationDefinite Purpose Contactors and Starters
0 0A Compact Contactor 25 60A Starter Heavy-Duty Special Purpose.1 Product Overview Contactors and Starters Product Overview........................................ Application Description....................................
More informationSquare D General Purpose Relays
Square D General Purpose Relays Class 0R plug-in relays 0RS (SPDT) 0RS (DPDT) 0RS3 (3PDT) 0RS (PDT) Catalog 0 Contents Class 0R plug-in relays bbspecifications....................................................
More informationBENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:
SERIES 782XBX/XDX DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FEATURES FLAG INDICATOR: L.E.D. STATUS LAMP: PUSH BUTTON: LOCK-DOWN DOOR: FINGER-GRIP COVER: I.D. TAG/WRITE LABEL: COVER ADAPTERS: BENEFITS
More information37T Series Moisture Resistant Temperature Controls
37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a
More informationFile E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:
File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,
More informationRelays. Industrial Automation Catalog Section - U906. Selection Guides. Solid State Relays RSS Series
Industrial Automation Catalog Section - U906 Relays Selection Guides Solid State Relays For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com or 800-262-IDC..
More informationAP/UP, AP/MIL Series Magnetic Circuit Protectors
AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables
More informationRelays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series
Industrial Automation Catalog Section - U906 Relays Selection Guides General Purpose Relays RU Series RR Series For up-to-date information, or to request a full copy of this catalog, contact us at www.idec.com
More informationcontactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.
DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally
More informationNRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations
More informationFeatures. Type List A
Type List Terminal style PCB terminal A Contact form (SPNC) (SPNC) eatures Heavy duty 30A general purpose Power Relays. UL/CUL (UL 508 & 873), VDE safety approvals. Optional for open frame, dust cover,
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationAC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel:
Specification MIL-C-2212 Application Motor control, heater and tungsten lamp switching. Type Select standard type (IC5181C) or quiet type (IC5181D) when control is to meet standard MIL-C-740. All quiet
More informationJOSLYN CLARK VACUUM CONTACTORS
COLTERLEC ELECTRICAL ENGINEERING PRODUCTS SECTION JOSLYN CLARK VACUUM CONTACTORS COLTERLEC ELECTRICAL ENGINEERING PRODUCTS 339 TM CONTENTS Joslyn Clark - New 300Amp, 1140 Volt Heavy Duty Mining Vacuum
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationSealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F
8H Type List 8H Terminal style Contact form Features Miniature PCB Power Relays A 2VAC. High CTI 2 material or product comply with IEC 33-1 are available. UL Insulation Class F. VDE, UL/CUL, TUV, CSA/CUS
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationHOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1
MERCURY TO METAL CONTACTORS AND RELAYS GLASS SEAL GUIDE RETAINER TEFLON GUIDE MAGNETIC SLEEVE BOBBIN TERMINAL WELD RING CERAMIC INSULATOR ELECTRODE METAL CAP DESCRIPTION MERCURY TO METAL CONTACTOR: The
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationHigh barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,
More informationHEAVY DUTY POWER RELAYS FEATURES
VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for
More informationFeatures. Type List 832A
Type List Terminal style PCB terminal A Contact form (SPNC) (SPNC) Insulation eatures Heavy duty 30A general purpose Power Relays. UL/CUL (UL 508 & 873), VDE safety approvals. Optional for open frame,
More information7000 series. Industrial Electropneumatic Timing Relay AGASTAT. Design Features. On-delay model 7012 (delay on pickup) Design & Construction
7000 series Industrial Electropneumatic Timing Relay File E15631 File LR29186 Note:7032 types and certain models with accessories are not agency approved. Users should thoroughly review the technical data
More informationSeries L9 UL-489 Miniature Circuit Breakers
Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationNRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
RA Series RA Series RAS RA Key features of the RA series include: Available in 4 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over
More informationProduct index. 4 - Manual motor protectors. Phone: Fax: Web: -
Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationPage 2-4 Page 2-8. Page Page 2-13
Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationSingle Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.
Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The
More informationGeneral Purpose Relay
General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge
More informationNo-barrier design Self-extinguishing materials Front-connected, back-connected and flush-mounted styles Blades operate independently or can be ganged together Recognized by UL and cul STATES Type have
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationDefinite purpose contactors
Definite purpose contactors Three-pole and four-pole non-reversing DP contactors 600VAC T4 DPBF09 - DPBF12 - DPBF18 - DPBF09 T4 - DPBF12 T4 - DPBF18 T4 DPBF26A DPBF32A DPBF50 DPBF80 Motor Locked Rotor
More informationControls. CONTACTORS CWB Line (up to 40A)
Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel
More informationPB-Series. GFCI/ELCI & Panel Seal
PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.
More information50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 7842 40A 600V 2P Switch Pass & Seymour/Legrand Catalog Number 7842 Manufacturer Pass & Seymour/Legrand Weight per unit
More informationSERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES
TO 1 (4) A 50 V AC PRODUCT FEATURES 100 million times proven switching principle High, fl exible design variety Excellent actuating characteristic Illuminated and non-illuminated variants ON REQUEST Other
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More informationNon-illuminated Push Buttons
Non-illuminated Push Buttons 3 Accessories for push buttons Lockout attachment Contact block kits Lens kits Wobblestick kit Push Button Cap Interchangeable, snap-in design Protective caps 9 colors: red,
More informationDrop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes
Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes Patent Pending File E320908 All contact ratings and coil versions may not be UL recognized.
More informationDefinite Purpose Contactors Types DP, DPA, and SYD Class 8910
s DP, DPA, and SYD Class 89 Compact Design Industry Standard Mounting Double Brea Contacts Low Coil VA Straight-Through Wiring Low Cost Definite purpose contactors are ideal for heating, air conditioning,
More informationG-Series. Circuit Breaker.
-Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current
More informationElectrical Components
Table of Contents ELECTRICAL COMPONENTS Electrical Components 3 ELECTRICAL COMPONENTS 1 Electrical Cables.... 3-1 - 3-2 Hitch Ball & Grounding Jumpers.... 3-3 Fuses... 3-4 - 3-6 Fuse Packages... 3-7 Cord
More informationJOSLYN CLARK VACUUM CONTACTOR FEATURES
USAVAC COPACT INTERNATIONAL AC VACUU CONTACTOR International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500V Joslyn Clark s unique Compact AC Vacuum Contactors & Starters
More informationFile E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany
File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above
More informationRSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)
RSS Series Panel Mount Solid State Relays Key features of the RSS series include: Photo isolation 1,200 volt blocking voltage 4,000 volt optical isolation Zero voltage turn-on 100% tested at rated current
More informationSection. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...
Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker
More informationRelays & Sockets. RQ Series PCB Relays
RQ RQ Series PCB Relays IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small, yet maintain high contact ratings and long operational life. For larger
More informationMATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation
MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation
More informationProduct Selection 3-Pole Contactors
- Contactors and January 0 Vol., Ref. No. [06] Product Selection -Pole Contactors When Ordering Specify Select required contactor by Catalog Number and replace the magnet coil alpha designation in the
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationIndustrial Relay KML(1C, 2C)
Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations
More informationFunction Relays, Interfaces and Converters
Function Relays, Interfaces and Converters Interface Relays Narrow Design 3TX70 interface relays 3TX701 Interface relay, plug-in Plug-in socket interface, complete with relay Contact Rated control Width
More informationPower Switching Devices
Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier
More information