HGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.
|
|
- Mavis Rich
- 5 years ago
- Views:
Transcription
1 HA Hinged Armature Auxiliary Hinged armature auxiliary relay to perform auxiliary functions in and circuits. eatures and Benefits Molded case with 4 mounting options Drawout case available Applications multiplication Protection and Control Standard, low and variable time pickup available undervoltage (low dropout) E Multilin
2 Applications The HA hinged armature auxiliary relays are designed to provide additional contacts, higher contact carrying and interrupting ratings, timing, interlocking, electrical separation, or other auxiliary functions. Where more than two circuits are to be controlled, the coils of two or more relays may be connected either in parallel on or in series or parallel on to obtain the desired results. eneral-purpose Relays Standard : The HA is the standard auxiliary relay which is instantaneous in operation and is used for auxiliary functions where intentional delays of over -/4 to cycles are not required and where standard pickup values, as listed in the table, are satisfactory. The contact arrangement for each relay (or unit) is doublepole, double-throw ( normally open, normally closed). Low Pick-up: The HA4 relay has been designed with a shorter armature gap which is obtained by the setting of an adjustable back contact. This construction allows a lower pickup value than normal and a faster pickup time. Also, relays are available for tripping duty and target operation with pickup times of / cycle on a 0-cycle basis, and are intermittently rated. The contact arrangement is one single-pole, double-throw contact and one normally open contact for each relay (or unit). The second normally closed contact is not used with the low pickup setting. This second contact can be used if the wipe is restored to normal and the control spring tension increased thus raising the pickup toward the 80 percent (0 percent cold) level which would apply with standard gap relays. Undervoltage Low Dropout. The HA4BH(-)A relay is a three-phase residual voltage relay with low dropout. A primary application is as on automatic throwover schemes where induction motors are the principal load. Time-Delay Relays ixed-time Dropout. The HA is designed to provide a timedelay dropout of approximately cycles (0-cycle basis). The delay is obtained by momentarily sustaining the magnetic flux at the relay pole face by means of induced currents in a copper ring which acts as a shorted one-turn coil. A small delay in pickup time is also obtained since the induced currents also tend to retard the buildup of the relay magnetic field. Operating times are measured at or from rated voltage or amperes for pickup and dropout times respectively. Adjustable-time : The HA4D has a resistor-capacitor timing circuit with the resistor being adjustable to vary the charging time of the capacitor which is connected across the relay operating coil. arrangement for the fixed-time dropout (HA) is one single-pole, double-throw contact and one normally open contact per relay (or unit). Relay Characteristics Voltage or Current Values. The values listed in the table below apply as indicated for all relays. Ratings Standard Relays - HA The current-closing rating of the contacts is 0 A. The currentcarrying rating is A continuously or 0 A for one minute. Interrupting Ratings of s in Amperes -circuit Single V V Break NONINDUCTIVE CIRCUITS INDUCTIVE CIRCUITS - 0. Double Break Low Relays HA4, HA The current closing ratings of the contacts is 0 A. The current carrying rating is A continuously or 0 A for one minute. The interrupting ratings (noninductive circuits) for the various voltages are as follows: -circuit V V NONINDUCTIVE CIRCUITS - INDUCTIVE CIRCUITS - Single Break
3 Relay Percentage of Rated V or A Classification Value Dropout Value HA Standard 80% 80% -0% -% HA4 Low % 0% 0-0% -% HAA,B,C Time 0-% 0-0% -% -% HAD,H Time 80% Max. 0% Max. -% -% BC surface mounting with cover BC semi-flush mounting with cover C surface mounting with cover C surface mounting with cover with provisions for front mounting HA Order Code Breakdown Standard HA * ** * A J S Surface mounted front connected with solid cover Surface mounted front connected with solid cover and provision for front mounted Electrical data (see column under Selection guide) Hz 0 Hz N.O. N.C C Res Wt. in lbs (kg) (0.) (.4) Order Code Breakdown HA *** **** B 4B4 J Standard pickup general purpose double unit Standard pickup general purpose single unit Low pickup general purpose single unit Low pickup general purpose double unit Single short gap unit with rectifiers (0 cycles, low burden) Low pickup time delay single unit, fixed time ( cycles min. dropout) (copper slugged coil) Electrical data (see column under Selection guide)
4 Drawout Case Relays Option B B B B B B B B B B J A A A 4A A A 8A 4A 80A 4A A A A A 4A A A A A A A A A A A 4A A A A A A A A A A A 4A A A 8A 4A 80A 4A A A A 4A A A A A 4. 4, V 0 Hz V 0 C Each Unit Z ➀ ➀ Time Case S S S S S. Wt. in lbs (kg) (.) (.) () () () ➀HA (standard pickup) double pole, double throw { normally open/two normally closed} per unit. HA4 (low pickup) one single pole, double throw. HA (time delay) plus one normally open contact per unit. 4
5 HA4 order Code Breakdown Adjustable Time Delay on HA4 * * D X Back connected with cover Electrical data (see column under Selection guide) 4 Volts or Less N.O. N.C Wt. in lbs (kg) 8 (.) (.4) HA4 order Code Breakdown Molded Case Tripping Relays, / Cycle or Less (for tripping two breakers) HA4 ** ** AM AL Back connected with cover ront connected with cover Electrical data (see column under Selection guide) Volts 80% or Less N.O. N.C or A AM or A or 0. A AM or 0. A or Carrier CX or CY AL. Wt. in lbs (kg) (0.) (.4)
6 HA4 Order Code Breakdown Low (% of rating for or 0% of rating for ) HA4 * ** * A A Surface mounted front connected with solid cover Electrical data (see column under Selection guide) Hz 0 Hz N.O. N.C C Res Wt. in lbs (kg) (0.) (.4) HA Order Code Breakdown Time Delay, ixed Time ( cycles dropout) (copper slugged coil) HA * ** * A C H ront connected with solid cover (NO STUDS) Electrical data (see column under Selection guide) /0 Hz N.O. N.C C Res.. Wt. in lbs (kg) (0.) (.4)
7 HA order Code breakdown ixed Time with. -cycle Delay on Dropout HA * ** * D H ront connected with solid cover (NO STUDS) Electrical data (see column under Selection guide) /0 Hz N.O. N.C. Volts 0% 80% C Res.. Wt. in lbs (kg) (0.) (.4) Order online save time
Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS
1 Module 2 CONTROL SYSTEM COMPONENTS Lecture - 4 RELAYS Shameer A Koya Introduction Relays are generally used to accept information from some form of sensing device and convert it into proper power level,
More informationwww. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.
NSTRUCTONS MAGNETC TME RELAYS *C2820-054 *Also identified with prefix CR instead of C. GENERAL. ELECTRC GEH-85F NTRODUCTON The CR2820-054 relay is a d-e operated relay. t may be applied as an instantaneous
More informationCOM Overcurrent Relay
41-102.1B COM Overcurrent Relay Figure 1: COM-5 Class 1E Relay (Front View) 9664A28 Photo Figure 2: COM-5 Class 1E Relay (Rear View) 9664A29 Photo Photo needed here 2 COM Overcurrent Relay 41-102.1B 3
More informationABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet
ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,
More information3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay
41-106E Type CO-4 Step-Time Overcurrent Relay A core screw accessible from the top of the switch provides the adjustable pickup range. The IIT contacts are connected in the trip circuit to trip instantaneously.
More informationL. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)
Figure 1: Types CA-16 Relay (front view) Photo Figure 2: Types CA-16 Relay (rear view) Photo 2 Sub 5 185A419 Sub 6 185A443 Figure 3: Internal Schematic of the Type CA-16 bus Relay or CA-26 Transformer
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.
September, 1990 Supersedes Descriptive Bulletin 41-100, pages 1-4, dated June, 1989 Mailed to: E, D, C/41-100A Hi-Lo co induction-disc type overcurrent relays are activated when the current in them exceeds
More informationGEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA
GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K GE Protection and Control 205 Great Valley Parkway Malvern, PA 19355-1337 GEK-41931 CONTENTS PAGE DESCRIPTION 3 APPLICATION 3 TABLE I 3
More informationA - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION
ABB Effective: November 1990 This Addendum Supersedes all Previous Addenda Addendum to Instruction Leaflet 41-137.3H Type KRD-4 Directional Overcurrent Ground Relay A - Add New Information C - Change Existing
More informationTYPE KF UNDER-FREQUENCY RELAY A. Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) Front View Rear View
41-503.21A TYPE KF Front View Rear View Figure 1: Type KF Relay for 60 Hertz without Case. (Front & Rear View.) 2 TYPE KF 41-503.21A lower pin bearing, which is mounted on the frame, with respect to the
More informationInverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products
Station Automation & Protection Inverse-Time Overcurrent & /F Relays Type ICM, ICM B ABB Substation Automation Products Features the driving solenoid has tappings, corresponding to the seven stages of
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More informationINSTRUCTIONS. GEI-38974A Supersedes GEI INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC
INSTRUCTIONS GEI-38974A Supersedes GEI 38974 INSTANTANEOUS CURRENT RELAY TYPE PJC2OA GENERALS ELECTRIC 2 DESCRIPTION APPLICATION MOUNTING SERVICING RENEWAL PARTS 10 PICKUP AND RESET ELECTRICAL TESTS ELECTRICAL
More informationINSTRUCT IONS GEH-1 793J INSTANTANEOUS AUXILIARY RELAY TYPES HGA11A, C, H, J, K, P, S, T, V, W, X GENERAL ELECTRIC AUILIARV P A GENERALS ELECTRIC
GENERALS ELECTRIC AUILIARV P A GENERAL ELECTRIC HGA11A, C, H, J, K, P, S, T, V, W, X TYPES INSTANTANEOUS AUXILIARY RELAY 0 INSTRUCT IONS GEH-1 793J 2 RENEWAL PARTS 8 CONTACT CLEANING 8 PERIODIC CHECKS
More informationC. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View
Figure 1. CA-16 Front View Figure 2. CA-16 Rear View 2 2.1. Restraint Elements Each restraint element consists of an E laminated electromagnet with two primary coils and a secondary coil on its center
More information2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay
41-100K 2.0 CONSTRUCTION AND OPERATION The type CO relays consist of an overcurrent unit (CO), either an Indicating Switch (ICS) or an ac Auxiliary Switch (ACS) and an Indicating Instantaneous Trip unit
More informationDC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data
DC Loop Contactors, Contactor Lugs and Dynamic Brakes Technical Data Table of Contents 1370 DC Loop Contactors....................................3 Catalog Number Explanation...............................3
More informationABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA
ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA Instruction Leaflet I.L. 41-661.1B Effective: June 1997 Supersedes I.L. 41-661.1A, Dated February 1994 Type
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationTABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING
the voltage unit contacts, this effect is negligible. 3.2 Trip Circuit The main contacts will close 30 amperes at 250 volts dc and the seal-in contacts of the indicating contactor switch (ICS) will carry
More informationINSTRUCTIONS GEI-98305C UNDERVOLTAGE RELAY D-C. Type NGV18A GENERAL ELECTRIC
INSTRUCTIONS GEI-98305C D-C UNDERVOLTAGE RELAY Type NGV18A GENERAL ELECTRIC 2 Fig (8035275) NOV18A Relay Removed From Case (Rear View) GEI-98305 D-C Undervoltage Relay Type NOV Fig. 1 (8035274) NGVI&L
More informationInstallation Sheet January, 2016 Supersedes February, 2013
s Installation Sheet January, 016 Supersedes February, 013 E87010-A0104-T003-A6-CLM0 Lighting and Heating Contactor 30 Amp, 3, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting
More informationCX-Series. Circuit Breaker
CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications
More informationDETAIL SPECIFICATION SHEET
INCH-POUND MIL-DTL-17361/4B(SH) 19 September 2006 SUPERSEDING MIL-C-17361/4A(SH) 13 March 1995 DETAIL SPECIFICATION SHEET CIRCUIT BREAKERS, AIR, ELECTRIC, INSULATED HOUSING (SHIPBOARD USE) TYPES AQB-A101,
More informationABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet Effective: October 1999 Supersedes I.L. 41-133R, Dated August 1998 ( ) Denotes Changed Since
More informationInverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B
Inverse-Time Overcurrent & E/F Relays Type ICM 21, ICM 21B ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve
More informationModel HEA Multicontact Auxiliary
GE Grid Solutions Model HEA Multicontact Auxiliary Features and Benefits Electrically separate outputs available Various shaft lengths available Locks equipment out of service Applications Contact multiplication
More informationGENERAL ELECTRIC INSTRUCTIONS GEK- 2M42. Insert Rooklet GEH 1793 INSTANTANEOUS AUXILIARY RELAY TYPE HGA MODEL 12HGAI1E(-)A I NTRODUCT ION
PHILAO[LPHA. PA GENERAL ELECTRIC POWER SYSTEMS MANAGEMENT DEPARTMENT latter should be referred to the General Electric Co.pany. probli erlie which are not covered sufficiently for the purchasers purpose.,
More information4.0 OPERATION Type ITH-T Relay
41-771.2 Type ITH-T Relay 3.3 OPERATION INDICATOR This operation indicator is a small solenoid coil connected in the trip circuit. When the coil is energized a spring-restrained armature releases the white
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationFigure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E
Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) 41-242.5E 2 Typical 60 Hertz time product curves for the type CWP-1 relay are shown in Figure 4 with 100 volts
More information2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT
41-348.11C SA-1 Generator Differential Relay - Class 1E 2.0 CONSTRUCTION The type SA-1 relay consists of: Restraint Circuit Sensing Circuit Trip Circuit Surge Protection Circuit Operating Circuit Amplifier
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationF-Series. Circuit Breaker
F-Series Circuit Breaker The F-Series hydraulic/magnetic high amperage circuit breakers are designed to handle high current applications in extremely hot and/or cold locations. Due to its timeproven hydraulic/magnetic
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More information34 th Hands-On Relay School
34 th Hands-On Relay School Generation Track Overview Lecture Generator Design, Connections, and Grounding 1 Generator Main Components Stator Core lamination Winding Rotor Shaft Poles Slip rings Stator
More informationABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION
ABB Instruction Leaflet 41-163.2B Effective: January 1977 Supersedes I.L. 41-137.3A, Dated September 1974 ( ) Denotes Change Since Previous Issue Type CRQ Directional Negative Sequence Relay for Ground
More informationB CW POWER RELAY
41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large
More informationCritical Power Switchboards. Selection and Application Guide
Selection and Application Guide Siemens RCIII (rear connected) switchboards utilizing Siemens Type SB Encased Breakers are a perfect solution for your critical power distribution needs. Whether your installation
More informationCrane Control Class 9055
Catalog 17 CONTENTS Description.....................................................Page pplication Data................................................... General Information and Pricing.......................................
More informationINTERPLANT STANDARD - STEEL INDUSTRY
INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION FOR MAGNETIC OVER- CURRENT RELAYS FOR ac AND dc MOTORS PROTECTION UP TO 650 V (FIRST REVISION) CORRESPONDING INDIAN STANDARD DOES NOT EXIST IPSS:1-04-008-11
More informationINSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS
g INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS Manual Part Number: GEI-83964H Copyright 2000 215 Anderson Avenue Markham, Ontario L6E 1B3 Canada Telephone: (905)
More informationIN2 Enclosed Switches and Circuit Breakers
Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals
More informationInstallation Sheet January, 2016 Supersedes June 2013
s Installation Sheet January, 016 Supersedes June 01 E87010-A0105-T00-A6-CLM0 Lighting and Heating Contactor 60, 100, 00 Amp,, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting
More informationType CRN-1 Reverse Power Relay 50 and 60 Hertz
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-251.2P Effective: June 1991 Supersedes I.L. 41-251.2N Dated April 1988 ( )Denotes Change
More informationSURE-TRIP OEM RELACEMENT TRIP UNIT
RMS CURRENT MEASUREMENT with SURE-TRIP OEM RELACEMENT TRIP UNIT Update Circuit Breaker Solid State Controls with SURE-TRIP LOGIC The SURE-TRIP Solid State Tripping Systems Have Been Designed, Tested And
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationCircuit breaker interlocking and operation requirements SIEMENS
Circuit breaker interlocking and operation requirements SIEMENS When manufacturers and specifiers discuss circuit breaker operational and interlocking requirements, several terms are used repeatedly. Despite
More informationTechnical Information
-100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42
More information1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.
RC SCOPE This test procedure covers the testing and maintenance of Westinghouse RC relays. The Westinghouse Protective Relay Division was purchased by ABB, and new relays carry the ABB label. Refer to
More informationType SOQ Negative Sequence Time Overcurrent Relay
ABB Power T&D Company Inc. Power Automation & Protection Division Coral Springs, FL Allentown, PA April 1998 Supersedes DB dated August 1991 Mailed to: E,D, C/41-100B For Protection of Rotating Machinery
More information6R MATRIX. Modular Relays. rms. Auxiliary, Trip & Supervision Relays
6R MATRIX Modular Relays Auxiliary, Trip & Supervision Relays > > Rugged modular construction > > Rack or flush mounting > > Range of function types > > Draw out module > > 5, 10 & 20 contact versions
More informationFULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION
505 z 509 FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION The movable contacts are carried in stainless steel cages which in turn are mounted in cavities in the molded portion of the cross bar. This
More informationSURE TRIP RETRO KITS
RMS CURRENT MEASUREMENT with SURE TRIP RETRO KITS Circuit Breaker Solid State Controls with SURE TRIP LOGIC The Sure Trip Solid State Tripping Systems Have Been Designed, Tested And Produced To all Applicable
More informationMERCURY CONTACTORS & RELAYS
MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND
More informationPRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT
Sheet 1 of 6 Order Number Serial Number PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT Issue Date Level A 22/10/02 Initial issue. Summary of changes Due to RMS continuous product improvement policy
More informationP. Sub 4 184A404. Sub 3 876A220
Figure 1. Type CRN-1 Relay Without Case. 1 = Directional Unit (D). 2 = Timer Unit (T). 3 = Indicating Contactor Switch (ICS). Sub 4 184A404 Sub 3 876A220 Figure 2. Internal Schematic of the Single Trip
More informationcontactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.
DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally
More informationINSTRUCTIONS SYNCHRONISM-CHECK RELAYS. GE Meter and Control. 205 Great Valley Parkway Malvern, PA Types IJS51A.
INSTRUCTIONS and hjs52a Types IJS51A J CLO%NG - -* RELAY GENERALtEL1CTRjC SYNCHRONISM-CHECK RELAYS 205 Great Valley Parkway Malvern, PA 19355-07 15 GE Meter and Control GEl! 1791? INSTALLATION PROCEDURE
More informationINSTRUCT ION S GEK A. Supersedes GEK TIME OVERCURRENT RELAY TYPE IAC66S GENERAL ELECTRIC
Supersedes GEK45344 GEK.45344 A GENERAL ELECTRIC TYPE IAC66S TIME OVERCURRENT RELAY INSTRUCT ION S GEK4 5344 CONTENTS PAGE DESCRIPTION 3 APPLICATION 3 RATINGS 3 INDUCTION UNIT 3 TABLE I 3 TABLE II 4 STATIC
More informationNRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that
More informationwww. ElectricalPartManuals. com Type CO Overcurrent Relays E ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA
Supersedes DB 41-100A, pages 1-12, dated November, 1988 Mailed to: E, 0, C/41-100A CO-2 eoa ABB Power T&D Company nc. Relay Division Coral Springs, FL Allentown, PA Non-directional, Single Phase, Adjustable
More information~ SERVICE SPECIFICATION SU-4522-A ~
WRBCC ~ ~ SERVICE SPECIFICATION SU-4522-A ~ ORP-66 PLUG-IN D. C. SWITCH OVERLOAD RELAY I. GENERAL The ORP-66 D. C. switch overload relay is furnished primarily for the overload protection of high voltage
More information2.3. Molded Case Circuit Breakers. Contents. Internal Accessories. Series C. Product Overview. Description
Molded Case Circuit s Series C.3 Series C Internal Accessories Contents Description Product Overview.......................... Standards and Certifications.................. Quick Reference...........................
More informationChapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.
Chapter 8 Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits. Article 430 of the NEC covers application and installation of
More informationSECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.
SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products
More informationSECTION MOTOR CONTROLLERS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph
More information(Example) In case of DC24 to 48V, it is operating time for DC24V.
7 9 8 Closing coil (CC) The closing coil is a device to close the breaker by remote control. An interlock to prevent pumping is provided electrically. CC circuit diagram Rated voltage (Applicable voltage
More informationInnovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual
Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION
More information41-747G. Figure 1: Type DGF Relay without case (Photo)
Figure 1: Type DGF Relay without case (Photo) 2 183A113 EDSK 205342 Figure 2: Internal Schematic of the Type DGF Relay in the FT21 Case. When a ground appears in the generator field, the dc milliammeter
More informationIndustrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw
Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator
More informationINSTRUCTIONS GEI-10190L DC AUXILIARY RELAYS TYPE HGA17A TO F, H, M, R, S, T GENERAL ELECTRIC
GENERAL ELECTRIC TYPE HGA17A TO F, H, M, R, S, T DC AUXILIARY RELAYS INSTRUCTIONS GEI-10190L RATINGS 3 CHARACTERISTICS a DESCRIPTION 3 CONTENTS PAGE BURDENS 4 CONSTRUCTION 4 LOCATION AND MOUNTING S MAINTENANCE
More informationPRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:
Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD
More informationAC Contactors. Type IC5181. Ward Leonard Electric Company Inc. 401 Watertown Road Thomaston, CT USA Tel:
Specification MIL-C-2212 Application Motor control, heater and tungsten lamp switching. Type Select standard type (IC5181C) or quiet type (IC5181D) when control is to meet standard MIL-C-740. All quiet
More informationPretest Module 21 Units 1-4 AC Generators & Three-Phase Motors
Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors 1. What are the two main parts of a three-phase motor? Stator and Rotor 2. Which part of a three-phase squirrel-cage induction motor is a
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More informationThe galvanic separation of the primary or actuating circuit and the load circuits
RELAY BASICS Relays are electro magnetically operated switches. An actuating current on a coil operates one or more galvanically separated contacts or load circuits. The electro mechanical relay is a remote
More information3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.
41-348.1H Type SA-1 2.1. RESTRAINT CIRCUIT The restraint circuit of each phase consists of a center-tapped transformer, a resistor, and a full wave rectifier bridge. The outputs of all the rectifiers are
More informationSECTION MOTOR CONTROLLERS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 MOTOR CONTROLLERS SPEC WRITER NOTE: Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationSectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications
Sectionalizing Rick Seeling Introduction Philosophy Pete Malamen Three Phase Reclosers High-Side Protection Specific Applications History Early 1970 s Small Substation Transformers
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationCHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR
100 CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR 6.1 INTRODUCTION Conventional energy resources are not sufficient to meet the increasing electrical power demand. The usages of
More informationAuxiliary Relay. Type RXP8n, RXPQ8n
Auxiliary Relay Type RXP8n, RXPQ8n ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
More informationMAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI
MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI 621213 QUESTION BANK --------------------------------------------------------------------------------------------------------------- Sub. Code : EE2402 Semester
More informationAMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism
AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism AMVAC Universal applications: Medium voltage motor starting applications Capacitor switching Retrofit applications to replace
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationAuxiliary Relay. Type P8n, PQ8n, PN8n
Auxiliary Relay Type P8n, PQ8n, PN8n ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
More informationMost home and business appliances operate on single-phase AC power. For this reason, singlephase AC motors are in widespread use.
Chapter 5 Most home and business appliances operate on single-phase AC power. For this reason, singlephase AC motors are in widespread use. A single-phase induction motor is larger in size, for the same
More informationCR193 Vacuum Limitamp* Contactors
GE Electrical Distribution GEH-5306C Maintenance Instructions CR193 Vacuum Limitamp* Contactors Contents Section 1 Introduction... 3 General... 3 Section 2 Description... 4 Principle of Operation... 4
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More informationGEK 45484B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAY HFA151 TYPE. GE Protection and Control 205 Great Valley Parkway Malvern, PA
GEK 45484B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAY TYPE HFA151 GE Protection and Control 25 Great Valley Parkway Malvern, PA 19355-1337 GEK 45484 CONTENTS PAGE DESCRIPTION 3 APPLICATION 3 RATINGS 3
More informationSECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
More informationCat. RK 47-2 E CASE AND MOUNTING. January 1967 DESIGN AND MODE OF OPERATION
The RIDA relay is a time-lag over-current relay whose operating time is independent of the current. The relay is available with different current scales for 50 Hz with the time-lag scale 0.2-6 s and for
More information