Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Size: px
Start display at page:

Download "Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035"

Transcription

1 Instruction Bulletin February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605

2 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Contents February 999 CONTENTS DSII AND DSLII LOW VOLTAGE POWER CIRCUIT BREAKERS Ordering instructions POLE UNITS Type DS-206, DSL-206, DSII-08, DSLII Type DS-206E, DS-206H, DS-206S, DS-46, DSL-46, DS-46H, DS-46S, DS-420, DSII-508, DSII-608, DSII-56, DSII-66, DSII-620, DSLII Type DS-62 and DSII Type DS-840 and DSII ARC CHUTES BARRIERS MAIN DISCONNECT CONTACT ASSEMBLY MECHANISM MECHANISM AND RELATED PARTS CONTROL COMPONENTS AUTOMATIC TRIPPING STSTEMS Current Sensors CURRENT LIMITING BREAKERS ACCESSORIES AND OTHER PARTS SWITCHGEAR CELL PROVISIONS AND UPGRADES RECOMMENDED SPARE PARTS FOR STOCK i

3 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts General Information DSII AND DSLII LOW VOLTAGE POWER CIRCUIT BREAKERS DIGITRIP Trip Unit Outside Wiring Guide Shutter Drawout Unit Position Indicator Padlock Plate Trip Plate Escutcheon Plate Nameplate Emergency Charging Handle Open-Close Indicator Close Bar Spring Charge indicator Front Cover : DSII-08 Breaker Front View Automatic Trip Relay (ATR) (optional) DIGITRIP Trip Unit Rating Plug Auxiliary Switch Wire Guide PT Module (80D Only) Auxiliary Switch (optional) Auxiliary Current Sensors Emergency Charging Handle Shunt Trip (optional) Direct Trip Actuator Levering Mechanism Assembly Overcurrent Trip Switch (optional) Spring Charge Motor (Power Operated Circuit Breakers Only) Opening Spring 2: DS-46 Breaker with Front Cover Removed

4 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Ordering Instructions February 999 Arc Chutes Secondary Disconnect Contact Mounting Frame Secondary Disconnect Contact Cover Moving Secondary Disconnect Contacts Auxiliary Switch (optional) Levering Arm Device Main Disconnect Contacts Roller (4 per circuit breaker) Sensors : DS-46 Breaker Side View without Barriers ORDERING INSTRUCTIONS. Check the nameplate to identify the type of breaker you have. 2. Identify the part(s) from the photos shown.. Determine the style number for the required parts. 4. Specify the quantity required. 5. Contact your local Square D Distributor to place your order. 2

5 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Pole Units POLE UNITS Type DS-206, DSL-206, DSII-08, DSLII : DS-206 and DSII-08 Pole Unit Assembly (Front View) 6: DS-206 and DSII-08 Lower Stud Assembly : DS-206 and DSII-08 Pole Unit Assembly (Rear View) 7: DS-206 and DSII-08 Upper Stud Assembly Description Required Per Breaker DS-206 and DSII-08 Style DSL-206 and DSLII-08 Style Three Pole Unit Assembly 4, 5 40D52G05 40D52G07 A three pole unit assembly includes: Molded Base Lower Stud Assembly 6 59C652G0 59C652G0 Upper Stud Assembly 7 59C65G0 59C65G0 Only available in a three pole unit assembly.

6 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Pole Units February 999 Type DS-206E, DS-206H, DS-206S, DS-46, DSL-46, DS-46H, DS-46S, DS-420, DSII-508, DSII-608, DSII-56, DSII-66, DSII-620, DSLII : DS-46 Pole Unit Assembly (Front View) 0: DS-46 Lower Stud Assembly : DS-46 Pole Unit Assembly (Rear View) : DS-46 Upper Stud Assembly Description No. No. Req d Per Breaker DS-206H, DS-206S DS-46, DSII-508 DSII-56 Style DSL-46 DSLII-56 Style DS-206E, DS-46H DS-46S, DS-420 DSII-608, DSII66 DSII-620 Style Single Pole Unit Assembly 8, 9 5D064G0 5D065G0 5D065G02 A single pole unit includes: Molded Base ➁ ➁ ➁ Lower Stud Assembly 0 26D298G06 9D6G04 9D6G05 Upper Stud Assembly 59C750G02 9D65G0 9D65G02 ➁ Only available in a single pole unit assembly. This is a direct replacement pole unit. It is different in appearance than the original. 4

7 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Pole Units Type DS-62 and DSII : DS-62 and DSII-62 Pole Unit Assembly (Front View) 4: DS-62 and DSII-62 Lower Stud Assembly : DS-62 and DSII-62 Pole Unit Assembly (Rear View) 5: DS-62 and DSII-62 Upper Stud Assembly Description Required Per Breaker DS-62, DSII-62 Style Single Pole Unit Assembly 2, 567F962G0 A single pole unit assembly includes: Molded Base Lower Stud Assembly 4 40D09G05 Upper Stud Assembly 5 26D299G02 Only available in a single pole unit assembly. 5

8 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Pole Units February 999 Type DS-840 and DSII : DS-840 and DSII-840 Pole Unit Assembly (Front View) 8: DS-840 and DSII-840 Lower Stud Assembly : DS-840 and DSII-840 Pole Unit Assembly (Rear View) 9: DS-840 and DSII-840 Upper Stud Assembly Description Required Per Breaker DS-840, DSII-840 Style Single Pole Unit Assembly 6, 7 567F99G0 A single pole unit assembly includes: Molded Base Lower Stud Assembly 8 40D778G0 Upper Stud Assembly 9 40D779G0 Only available in a single pole unit assembly. 6

9 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Arc Chutes ARC CHUTES Arc Chutes : DS-840 without Barriers : 2: : 24: Breaker Type Required Per Breaker Arc Chute Kit (Includes ) Style DS-206, DSL-206, DSII-08, DSLII-08 2 A568G0 DS-206E, DS-206H, DS-206S, DS-46, DS-46H, DS-46S, DSL-46, DS-420, DSII-508, DSII-608, DSII-56, DSII-66, DSII-620, DSLII A568G02 DS-62, DSII-62 2 A568G0 DS-840, DSII A568G04 7

10 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Barriers February 999 BARRIERS Barriers : DS-840 with Barriers : 28: : 29: Breaker Type Required Per Breaker Barrier Kit (Includes 4) Style DS-206, DSL-206, DSII-08, DSLII A569G0 DS-206E, DS-206H, DS-206S DS-46, DS-46H, DS-46S, DSL-46, DS-420, 27 4 A569G02 DSII-508, DSII-56, DSII-608, DSII-66, DSII-620, DSLII-56 DS-62, DSII A569G04 DS-840, DSII A569G05 8

11 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Main Disconnect Contact Assembly MAIN DISCONNECT CONTACT ASSEMBLY : : : 4: : Breaker Type Maximum Amp. Rating Required Per Breaker Main Disconnect Contact Assembly Kit DS-206, DSL-206, DSII-08, DSLII A570G0 DS-206H, DS-206S, DS-46, DSL-46, DSII-508, DSII-56, DSLII-56 6 A570G02 DS-206E, DS-46H, DS-46S, DS-420, DSII-608, DSII-66, DSII A570G0 DS-62, DSII A570G04 DS-840, DSII A570G05 A kit includes the total number of main disconnect contact assemblies required for one breaker. 9

12 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Mechanism February 999 MECHANISM Description Required Per Breaker All Types DS/ DSL DSII/DSLII except DS-62, DSII-62, DS-840, DSII-840 Style DS-62, DSII-62 Style DS-840, DSII-840 Style 5: Levering Mechanism Assembly Levering Mechanism Assembly 5 449D224G04 449D224G04 449D224G05 Crank Kit includes: Crank Arm with Roller, Special Bolt and Elastic Stop Nut A95G0 88A95G02 88A95G : Crank Kit MECHANISM AND RELATED PARTS : Electrically Operated with Closing Spring 40: Emergency Charge Handle Kit 4: Opening Spring : Manual Charge Handle Kit with Charging Cams 44: Trip Shaft Kit 8: Manual Mechanism with Closing Spring : Closing Spring Assembly 42: Oscillator Assembly Kit 45: Hold Pawl and Ratchet Kit 0

13 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Mechanism and Related Parts Description Mechanism Assembly without Closing Spring Includes: Main Drive Link Assembly (with roller) Oscillator Assembly Oscillator Reset Spring Emergency Charge Device Trip Latch, Trip Lever (for Motor Cutoff Switch) Trip Latch Reset Spring Mechanism Assembly without Closing Spring Includes: Main Drive Link Assembly (with roller) Trip Latch, Trip Lever (for Motor Cutoff Switch) Trip Latch Reset Spring Closing Spring Assembly Includes: Closing Spring and Spring Ends DS-206, DS-206S, DSL-206, DSII-08,DSLII-08 DS-206H, DS-46, DS-46S DSL-46, DSII-508, DSII-56, DSLII-56 DS-206E, DS-46H, DS-420, DSII-608, DSII-66, DSII-620 Emergency Charge Handle Kit Includes: Emergency Charge Device and Emergency Charge Handle Manual Charge Handle Kit Includes: Manual Charge Assembly and Manual Charge Handle and Charging Cams Oscillator Assembly Kit Includes: Oscillator Assembly, and Oscillator Reset Spring Required Per Breaker ALL DS/DSL, DSII/DSLII except DS-62, DS-840, DSII-62, DSII-840 Electrically Operated Style Manually Operated Style DS-62, DS-840,DSII-62, DSII-840 Electrically Operated Style Manually Operated Style 7 567F759G02 N/A 567F759G04 N/A 8 N/A 567F759G0 N/A 567F759G A67G0 79A67G A52G0 49A52G A67G02 79A67G A67G0 79A67G A96G02 N/A 88A96G02 N/A 4 N/A 88A96G0 N/A 88A96G0 42 A566G0 N/A A5566G0 N/A Opening Spring B907H0 698B907H0 698B907H0 698B907H0 Trip Shaft Kit Includes: Trip Shaft Lever, Trip Shaft, and Trip Shaft Return Spring 44 A567G0 A567G0 A567G0 A567G0 Hold Pawl and Ratchet Wheel Kit 45 A579G0 N/A A579G0 N/A Two Opening springs are required for DS-62, DS-840, DSII-62, DSII-840

14 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Control Components February 999 CONTROL COMPONENTS 46: 47: 48: Spring Charging Motor Kit Anti-Pump Relay Undervoltage Trip Assembly Description Spring Charging Motor Kit Includes: Motor Crank, Roller, Connectors, Mtg. Bracket and Hardware Anti-Pump Relay UNDERVOLTAGE TRIP ASSEMBLY WITH WIRES (INSTANTANEOUS) UNDERVOLTAGE TRIP ASSEMBLY WITH WIRES (TIME DELAY) Voltage 48 DC 25 DC 250 DC 20 60HZ HZ 48DC 25DC 250DC 20 60HZ HZ 20 60HZ HZ HZ HZ 48 DC 25 DC 250 DC 24 DC 5 50HZ HZ 20 50HZ HZ 45 50HZ HZ 20 60HZ HZ HZ HZ 48 DC 25 DC 250 DC 24 DC 5 50HZ HZ 20 50HZ HZ 45 50HZ HZ DS/DSL DSII/DSLII except DS-840 DSII-840 Style 449D4G0 449D4G0 449D4G02 449D4G0 449D4G02 829A05G0 829A05G04 829A05G05 829A05G0 829A05G02 752A05G0 752A05G02 752A05G0 752A05G04 752A05G05 752A05G06 752A05G07 752A45G0 752A45G02 752A45G0 752A45G04 752A45G05 752A45G05 752A45G06 752A06G0 752A06G02 752A06G0 752A06G04 752A06G05 752A06G06 752A06G07 752A46G0 752A46G02 752A46G0 752A46G04 752A46G05 752A46G05 752A46G06 DS-840 DSII-840 Style 449D4G0 449D4G0 449D4G02 449D4G0 449D4G02 829A05G0 829A05G04 829A05G05 829A05G0 829A05G02 752A25G0 752A25G02 752A25G0 752A25G04 752A25G05 752A25G06 752A25G07 752A45G0 752A45G02 752A45G0 752A45G04 752A45G05 752A45G05 752A45G06 752A26G0 752A26G02 752A26G0 752A26G04 752A26G05 752A26G06 752A26G07 752A46G0 752A46G02 752A46G0 752A46G04 752A46G05 752A46G05 752A46G06 LATCH CHECK SWITCH 49 ALL 40D6G0 40D6G0 Replacement shunt trip, spring release and undervoltage trip are complete assemblies and include mounting hardware and wire leads (not shown). If adding shunt trip, spring release or undervoltage trip to manual breakers; an auxiliary switch (page 4), and wiring guide kit (page 9) are required. Confirm that secondary contacts exist in the rear of the breaker. All changes or additions on the breaker should be wired per the standard drawing and indicate the change on the breaker nameplate : Latch Check Switch 2

15 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Control Components Description Voltage DS/DSL DSII/DSLII except DS-840 DSII-840 Style DS-840 DSII-840 Style Shunt trip Assembly with wires DC 2 DC 48 DC 25 DC 250 DC 20 60HZ HZ 752A02G0 752A02G02 752A02G0 752A02G04 752A02G05 752A02G06 752A02G07 752A22G0 752A22G02 752A22G0 752A22G04 752A22G05 752A22G06 752A22G07 50: Shunt Trip Assembly For use with Capacitor Trip (25VDC) 752A02G08 752A22G08 Overcurrent Trip Switch Manual Reset (2 Cont. with wires) 5 ALL 752A04G0 752A24G0 Overcurrent Trip Switch Manual Reset ( Cont. with wires) 5 ALL 752A04G02 752A24G02 5: Overcurrent Trip Switch Manual Reset Overcurrent Trip Switch Manual Reset (4 Cont. with wires) Overcurrent Trip Switch Electrical Reset Includes: coil (2 Cont. with wires) 5 ALL 752A04G0 752A24G DC 5 AC 25 DC 20 AC 250 DC 752A04G04 752A04G05 752A04G06 752A04G07 752A04G08 752A24G04 752A24G05 752A24G06 752A24G07 752A24G08 Overcurrent Trip Switch Electrical Reset includes coil ( Cont. with wires) 5 48 DC 5 AC 25 DC 20 AC 250 DC 752A04G09 752A04G0 752A04G 752A04G2 752A04G 752A24G09 752A24G0 752A24G 752A24G2 752A24G 52: Spring Release Assembly Spring Release Assembly with wires Motor Cut-off Switch Includes: Mounting Bracket and Insulation DC 25 DC 250 DC 20 60HZ HZ 752A0G0 752A0G02 752A0G0 752A0G04 752A0G05 752A2G0 752A2G02 752A2G0 752A2G04 752A2G05 5 ALL 567F40G06 567F40G06 Replacement shunt trip, spring release and undervoltage trip are complete assemblies and include mounting hardware and wire leads (not shown). If adding shunt trip, spring release or undervoltage trip to manual breakers; an auxiliary switch (page 4), and wiring guide kit (page 9) are required. Confirm that secondary contacts exist in the rear of the breaker. All changes or additions on the breaker should be wired per the standard drawing and indicate the change on the breaker nameplate : Motor Cut-Off Switch

16 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Automatic Tripping Systems February : New Auxiliary Switch Assembly Kit (round) - one high New Auxiliary Switch Assembly Kit (round) (Includes mounting bracket, switch, covers, and screw) High Assembly Kit 2 High Assembly Kit Additional Auxiliary Switch Assembly with cover (rectangular) ➁ 2nd Auxiliary Switch rd Auxiliary Switch Replacement Auxiliary Switches Assembly (rectangular) ➂ (Includes: switch, drive link and hardware) st Auxiliary Switch (ABAB only) 2nd Auxiliary Switch rd Auxiliary Switch Replacement Auxiliary Switch Only (rectangular) ABAB Auxiliary Switch AAAA Auxiliary Switch BBBB Auxiliary Switch AAAB Auxiliary Switch ABBB Auxiliary Switch A = N.O. B= N.C. Style A57G0 A57G02 697B56G08 697B56G09 697B56G04 697B56G05 697B56G06 449D622G 449D622G4 449D622G5 449D622G6 449D622G7 ➁ ➂ When adding an auxiliary switch, be sure that the wiring guides are installed. There are three wiring guides and they are located as follows: one inside and one outside on the left side of the breaker, and one between the right side of the trip unit and the auxiliary switch. Refer to on page and 2 on page for location and to page 9 for style numbers. Additional secondary contacts and covers may be required. Refer to on page 2 and page 9 for the style number. For adding to breakers with existing rectangular auxiliary switches. Used for replacement only of existing rectangular auxiliary switches. AUTOMATIC TRIPPING STSTEMS Digitrip Mounting Type of Trip Unit 50 with Gnd 50 without Gnd 60 with Gnd 60 without Gnd 80D with Gnd, ATR, and PT module 80D without Gnd and with ATR and PT module Style 694C75G0 694C75G02 694C75G0 694C75G C75G C75G : Direct Trip Actuator (DTA) Direct Trip Actuator (DTA) Style For use with Digitrip box 6482C55G28 For use with Digitrip Mounting 6482C55G Auxiliary CT Mounting Type with Gnd without Gnd Style 694C740G0 694C740G02 Digitrip ( 58) Trip Unit Trip Functions Style LI LSI LS LIG LSG LSIG 7829C05G0 7829C05G C05G0 7829C05G C05G C05G06 4

17 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Automatic Tripping Systems Digitrip ( 58) LI LSI LS LIG LSG LSIG 7829C0G0 7829C0G C0G0 7829C0G C0G C0G D 80D 80D 80D 80D 80D LI LSI LS LIG LSG LSIG 7829C54G0 7829C54G C54G0 7829C54G C54G C54G06 56: Digitrip Mounting with ATR and PT Module Digitrip Rating Plugs Digitrip Rating Plugs for 50, 60, 80D Rated Current l n Current Sensor Rating Hertz Style D8674G0 D8674G02 57: Auxiliary CT Mounting (for use with Digitrip Mounting) D8674G0 D8674G04 D8674G05 D8674G06 D8674G07 D8674G08 D8674G D8674G0 D8674G D8674G D8674G D8674G4 D8674G D8674G6 D8674G7 D8674G8 D8674G D8674G20 D8674G2 D8674G22 D8674G2 58: Digitrip with Rating Plug D8674G24 D8674G25 D8674G26 D8674G27 D8674G28 D8674G29 D8674G D8674G D8674G2 D8674G D8674G42 D8674G D8674G5 D8674G6 D8674G7 D8674G D8674G9 D8674G40 D8674G4 For use with forced air cooled DS-840 only. 5

18 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Automatic Tripping Systems February 999 Current Sensors 59: DS-206, DSII-08 Sensor with Spacer Sensor Ampere Rating Breaker Types ALL DS-206, DS-46, DS- 420 ALL DSII-08,DSII-508, DSII-608, DSII-56, DSII-66, DSII-620 All DS-46, DS-420 All DSII-56, DSII-66, DSII-620 Breaker Frame Rating Style 5D995G0 5D995G5 5D995G02 5D995G0 5D995G04 5D995G06 5D995G08 5D995G2 5D995G DS-420, DSII D995G DS-62, DSII DS-840, DSII D995G2 ➁ 5D995G24 ➂ 5D995G ➁ 5D995G2 ➂ 588C74G02 ➃ 588C74G DS-850, DSII C74G0 ➄ DS-206, DSII-08 Spacer Kit (For DS-206 & DSII-08 only. 794A965G0 ➅ Not required for DS-206E, DS-206H, DS-206S, DSII-508, or DSII-608) ➁ ➂ ➃ ➄ ➅ These are replacements for sensors style 794A70G series, and are for phase or neutral use, except as noted. For neutral use only. For phase use only. For DS-840 and DSII-840 only. For use with forced air cooled. Kit includes 2 spacers : DS-62, DSII-62 Sensor : DS-840, DSII-840 Sensor 6

19 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Current Limiting Breakers CURRENT LIMITING BREAKERS Description Required Per Breaker Style Blown Limiter Indicator Assembly 40D777G0 Blown Limiter indicator Assembly (For fuse Truck) 40D777G0 Isolating Transformer Assembly 59C755G0 Isolating Transformer Only 795A82H0 Includes transformers. Current Limiters 62: DSLII-56 (Front View) Breaker Type DSL-206, DSLII-08 DSL-206, DSLII-08 DSL-206, DSLII-08 Required Per Breaker Amp Rating Style 40D6G0 40D6G02 40D6G0 DSL-206, DSLII-08 DSL-206, DSLII-08 DSL-206, DSLII D6G04 40D6G05 40D6G06 DSL-206, DSLII-08 DSL-206, DSLII-08 DSL-206, DSLII D6G07 40D6G0 40D6G DSL-206, DSLII-08 DSL-46, DSLII-56 DSL-46, DSLII D6G2 5D92G0 5D92G02 DSL-46, DSLII-56 DSL-46, DSLII-56 DSL-46, DSLII D92G0 5D92G04 5D92G DSL-46, DSLII-56 DSL-46, DSLII D92G09 5D92G0 6: DSLII-56 without Barriers (Rear View) Drawout Fuse Truck Type Current Limiters Truck Type DSL-200 DSLII-200 DSL-4000 DSLII-4000 Required Per Breaker Amp Rating Style 5980C0G0 ➁ 5980C0G02 ➁ 5980C0G0 ➁ 5980C0G0 ➁ 5980C0G02 ➁ 5980C0G0 ➁ 5980C0G04 ➁ ➁ Limiters are mounted on a separate fuse truck. 7

20 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Accessories and Other Parts February 999 ACCESSORIES AND OTHER PARTS : Replacement Nameplate (DSL Shown) 67: Portable Lifter (Style RC000) : DS and DSII Breaker Label Kit (Style 887A84G0) 68: Lifting Yoke (Spreader Bar) (Style , ) : DSL and DSLII Breaker Label Kit (Style 8A07G0) 69: Levering-In Tool (Style ) 8

21 Bulletin No February 999 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Accessories and Other Parts 70: Fastener Kit (Style 586A86G0 ) Each kit includes 84 fasteners in various sizes and quantities of the types shown in 70 Description Replacement Nameplate Secondary Disconnect Contact Secondary Disconnect Contact Cover Secondary Disconnect Mounting Frame with 8 point contact block Drawout Breaker Front Covers for Digitrip Box No. Use Application Style 64 Used to replace the nameplates on the front of the breaker For Disconnecting secondary control Covers top of secondary contacts For replacing secondary disconnect mounting frame, or for adding to breaker originally supplied without secondary contacts DS Dummy DS Drawout DSL Fuse Truck DS Fixed DS/DSL DS/DSL DS/DSL Covers Front of Breaker All DS (except DS-62 /DSII-62 DS-840/DSII-840) 994D95H6 994D95H6 994D95H64 994D95H65 994D95H67 59C498G06 50B569H0 59C498G07 567F498H0 7: Finger Cluster Removal Tool (Style 59C90G0) Escutcheon Plate DS-62, DSII-62 DS-840, DSII-840 DSL-206 DSL-46 DSLII-08 DSLII-56 Mounts on front cover All DS/DSII Breakers All DSL /DSLII Breakers 567F499H0 567F50H02 567F498H0 567F498H0 567F498H0 567F498H0 695C02H0 695C0H0 Breaker Roller Kit (double edge type) and Retaining Rings To roll the breaker in and out of the housing (Set of four) All Breakers A578G0 Wiring Guide Kit Guides for wiring All DS (except DS-840) A588G0 72: 7: Breaker Test Kit and Adapter (Style 8779C02G02) Test Kit Adapter (Style 8779C02G0) DS-840 All DSL Breaker 5D48G0 A589G0 Wire Channels Guides for wiring DSII/DSLII 5D48G02 Wire Support Spacer Secondary Contact Block Assembly Right Hand Side Support Secondary Contact Frame Wire Support Bracket Communications Receptacle Assembly Right Hand Wire Retainer Right Hand Wire Retainer Right Hand Wire Through Spacer for wire channels Disconnecting secondary control For mounting secondary contact blocks For mounting secondary contact blocks DSII/DSLII DSII/DSLII DSII/DSLII DSII/DSLII 88A97H0 69C68G0 695C8H02 695C49G0 Support wire channels DSII/DSLII 795C072H02 N/A Disconnecting communications DSII/DSLII 806A80G0 Guides for wiring DSII 47B242H04 Guides for wiring DSLII 47B242H05 Guides for wiring DSLII-08,DSLII- 46, DSLII C989H04 Customer is to provide the following original information: GO, P.O., Item, FN and Option s. 9

22 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Bulletin No Switchgear Cell Provisions and Upgrades February 999 SWITCHGEAR CELL PROVISIONS AND UPGRADES If the original switchgear has blank compartments or if an existing breaker needs to be upgraded, cell parts can be ordered. They typically include some or all of the following parts: Mounting pan, extension rails, and push-to-trip mechanism Interference brackets Polyester backplate (CT mounting plate) Line and load stabs Load bus runbacks, extensions, supports, and lug adapters Door with handle, hinge and trip button Gas and arc shields Seismic positioner Contact your local Square D sales representative with the following information: Factory Order number Date of manufacture RECOMMENDED SPARE PARTS FOR STOCK The quantities listed are recommended for 5 breakers of the same rating. Items 8-0 are only required for electrically operated breakers. The reference page number contains the complete styles of the required parts. Where needed, fill in or complete the style numbers for your application and forward to your local Square D sales representative. Item Quantity Description Pole Unit Assembly Main Disconnect Contact Assembly Kit Trip Shaft Kit Direct Trip Actuator (DTA) Opening Spring Fastener Kit Secondary Disconnect Contact Shunt Trip Assembly Spring Release Assembly Anti-Pump Relay Spring Charging Motor Kit Reference Page Style A570G A576G0 6482C55G 698B907H0 586A86G0 59C498G06 752A G0_ 752A G0_ 829A05G 449D4G0_ 20

23

24 Trademark Acknowledgements DIGITRIP is a registered trademark of Cutler-Hammer. Square D Company 500 S. University Blvd. Middletown, OH, USA (5) Square D, POWERLOGIC, SY/LINK, SY/MAX, SY/NET and are registered trademarks of Square D Company. System Manager is a trademark of Square D Company. All other trademarks are the intellectual property of their respective companies. Electrical equipment should be serviced only by qualified electrical maintenance personnel. No responsibility is assumed by Square D for any consequences arising out of the use of this material. Bulletin No February 999. Replaces 605- dated 0/92.

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application...

More information

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1 New Information Supersedes Data 33-790-1H, dated October 1996 DS/DSII Low Voltage Switchgear Page 1 DS Switchgear Assembly DSII Switchgear Assembly Contents Pages DS Switchgear (Front View) 2 DSII Switchgear

More information

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF New Information Control Relay Auxiliary Switch Operating Mechanism CutlerHammer Power Center 10 Maxwell Avenue Greenwood, SC 29646 1877276979 Closing Solenoid 2254 Renewal Parts for Low Voltage Power Circuit

More information

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII Effective July 2010 Supersedes July 1997 IB694C694-02 Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII Effective July 2010 PURPOSE This

More information

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....

More information

TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS

TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS om.c ww w.e lec tri ca lp ar tm an ua ls TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS Proven Technology with the Enhancements and Additional Ratings Our Customers Asked For

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION

More information

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA) Instructions for the Use, Operation and Maintenance of Types T-VAC and T-VACR Vacuum Circuit Breakers Effective November 2017 T- VACR Fixed (up to 25kA) T-VAC Draw out (up to 25kA) T- VACR Fixed (up to

More information

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION

DANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION Instruction Bulletin Bulletin No. 44027-017-01 Middletown, OH USA Class 6035 INTRODUCTION This bulletin contains instructions for adding a shunt trip assembly to a manual DS/DSL circuit breaker and modifying

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

IL 33-DRC-1 Retrofit System for Westinghouse and Cutler-Hammer DS Power Circuit Breakers. Table of Contents

IL 33-DRC-1 Retrofit System for Westinghouse and Cutler-Hammer DS Power Circuit Breakers. Table of Contents IL 33-DRC- Retrofit System for Westinghouse and Cutler-Hammer DS Power Circuit Breakers Table of Contents SAFETY PRECAUTIONS... How to Use this Manual...2 Work Sequence...2 Figure Work Sequence... 3 Tools

More information

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard

More information

Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data

Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data Effective May 2003 Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data Magnum IEC Air Circuit Breaker Product Family The New Magnum Narrow Frame Drawout Breaker and Cassette TD030003E

More information

Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers

Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers Instructions for the Use, Operation and Maintenance of Types VCP-TL and VCP-TRL Linear Magnetic Vacuum Circuit Breakers Effective May 2016 VCP-TRL Fixed (shown with optional protective relay installed)

More information

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING SAFETY PRECAUTIONS POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE BREAKERS AND THEIR ENCLOSURES ARE DESIGNED WITH SEVERAL BUILT-IN INTERLOCKS AND SAFETY FEATURES

More information

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200

More information

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table

More information

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers Supersedes IL 33-A46-2 Dated 01/04 Contents Description Page Introduction.............................. 3 Step 1: General Breaker Preparation......... 4 Step 2: Removing the Original Components.. 5 Step

More information

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2 SAFETY PRECAUTIONS POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE BREAKERS AND THEIR ENCLOSURES ARE DESIGNED WITH SEVERAL BUILT-IN INTERLOCKS AND SAFETY FEATURES

More information

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker IL 33-LGH-1 Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker SAFETY PRECAUTIONS WARNING POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE

More information

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25 Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25

More information

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING

www. ElectricalPartManuals. com Digitrip Retrofit System for Allis-Chalmers LA-4000 F Fused Breakers IL 33-A1K-1 WARNING SAFETY PRECAUTIONS WARNING POWER CIRCUIT BREAKERS ARE EQUIPPED WITH HIGH SPEED, HIGH ENERGY OPERATING MECHANISMS. THE BREAKERS AND THEIR ENCLOSURES ARE DESIGNED WITH SEVERAL BUILT-IN INTERLOCKS AND SAFETY

More information

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric RP 6118-1A Page 2

More information

SECTION 16426B. RELATED SECTIONS Section 16671A Transient Voltage Surge Suppression Section Microprocessor-Based Metering Equipment

SECTION 16426B. RELATED SECTIONS Section 16671A Transient Voltage Surge Suppression Section Microprocessor-Based Metering Equipment METAL-ENCLOSED DRAWOUT SWITCHGEAR (DSLII) LOW VOLTAGE PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install, where indicated on the drawings, a deadfront type, low voltage metal-enclosed

More information

Cutler-Hammer May 2001

Cutler-Hammer May 2001 Low-Voltage Power Circuit Breakers Magnum DS General Description Index Page General Description Magnum DS............. A1-1 General Description DSII/DSLII............... A1-7 Technical Data Magnum DS.

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

Switchgear. Low Voltage

Switchgear. Low Voltage January 2001 Vol. 1, Ref. No. [0923] -1 Low Voltage Switchgear Contents Description Page Magnum DS Metal-Enclosed Product Description........................................... -2 Application Description........................................

More information

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers .1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size

More information

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear 13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of

More information

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers Supersedes IL 33-GS8-2 Dated 10/00 (Manually Operated Only) Contents Description Page Introduction.............................. 3 Step 1:............................... 4 Step 2:...............................

More information

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers

Digitrip Retrofit System for Siemens-Allis RLX-1600 Breakers Contents Description Page Introduction.............................. 2 Step 1: General Breaker Preparation......... 3 Step 2: Removing the Original Components.. 3 Step 3: Installing the Sensors..............

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven

More information

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation

More information

Ampgard medium voltage motor control renewal parts

Ampgard medium voltage motor control renewal parts Technical Data TD020001EN Contents Description Page General information.... 2 3 400A starter design.... 4 9 800A starter design.... 10 15 Control and potential transformers.... 16 Current transformers....

More information

WLI Medium Voltage Switchgear Renewal Parts

WLI Medium Voltage Switchgear Renewal Parts Page 1 Supersedes Renewal Parts Data, pages 1-2, dated June 1992, WLI Medium Voltage Switchgear Renewal Parts Page 2 Standard Manually Operated Fused WLI Switch ➇ ➁ ➀ ➂➃ WLI Switch Mechanism ➉ ➈ m Replacement

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B. Cutler-Hammer Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv DANGER HAZARDOUS VOLTAGE. READ AND UNDERSTAND THIS BOOKLET IN ITS

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers Class 6037 CONTENTS Schneider Electric Brands Description Page Product Description..................................................

More information

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com -- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

Digitrip Retrofit System for BBC LKD 8 Breakers

Digitrip Retrofit System for BBC LKD 8 Breakers Supersedes IL 33-LK8-2 Dated 10/00 Contents Description Page Introduction.............................. 3 Step 1:............................... 4 Step 2:............................... 4 Step 3:...............................

More information

Evolution * Series E9000 Motor Control Center

Evolution * Series E9000 Motor Control Center GE Industrial Solutions Evolution * Series E9000 Motor Control Center Renewal Parts Bulletin Table of Contents Introduction The E9000-Line motor control center, a quality product of the General Electric

More information

17.1. Low Voltage Switchgear. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

17.1. Low Voltage Switchgear. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .1 Low Voltage Switchgear Magnum DS Metal-Enclosed Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organization dedicated to the support

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers VCP-T/T-VAC medium voltage vacuum circuit breakers Control protect with Eaton s compact medium voltage circuit breakers Eaton Corporation has dedicated years of research, design testing to create a comprehensive

More information

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1

www. ElectricalPartManuals. com It'll Cutler-Hammer WLI Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 1 t'll Cutler-Hammer Supersedes Renewal Parts Data, pages 1-2, dated June 1992 Renewal Parts Data Page 1 WL Medium Voltage Switchgear Renewal Parts Renewal Parts Data Page 2 WL Medium Voltage Switchgear

More information

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Cutler-Hammer Installation Instructions for the Digitrip OPTIM 550 3-Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Table of Contents Description Page 1.0 General Information......................1

More information

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi

.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi Low Voltage Switchgear Magnum DS Switchgear.1 Cross-Reference................................................ 102 Product Description............................................. 102 Application Description...........................................

More information

Digitrip Retrofit System for Allis-Chalmers G-25 Breakers

Digitrip Retrofit System for Allis-Chalmers G-25 Breakers Supersedes IL 33-AG6-2 Dated 02/08 Contents Description Page Introduction.............................. 3 Step 1:............................... 4 Step 2:............................... 4 Step 3:...............................

More information

Cable-Operated Disconnect Switches. Accessories

Cable-Operated Disconnect Switches. Accessories Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches

More information

Magnum IEC Air Circuit Breakers Price List All Prices in US$ for Export Sale

Magnum IEC Air Circuit Breakers Price List All Prices in US$ for Export Sale Effective: May 3 Magnum IEC Price List Prices in US$ for Export Sale Magnum IEC Air Circuit Breaker Product Family The New Magnum Frame Drawout Breaker and Cassette PL007E Magnum IEC Price List ( prices

More information

C1251N DC and C1251N 1000 V

C1251N DC and C1251N 1000 V T I Catalogue numbers C25N DC and C25N 000 V E2409 Compact C25N DC with magnetic trip unit (complete device - fixed/fc) Compact C25N DC P2 46034 P4 46036 C25N 000 V basic frame (separate components - fixed/fc)

More information

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1 Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear ABB Group February 25, 2015 Slide 1 SafeGear HD arc resistant switchgear 63 ka arc resistant metal-clad air insulated switchgear

More information

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Introduction A modular system of switchgear building blocks and cassettes provide untouchable

More information

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches 1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5

More information

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers

Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers Instruction Leaflet IL 33-FH6-2 Supersedes IL 33-FH6-1 Dated 11/99 Digitrip Retrofit System for the Federal Pioneer 25-H(L)-2, 30-H(L)-2, 30-H(L)-3, and 30-3 Breakers Contents Description Page Introduction..............................

More information

Powered by Safety 01.4IB.77000B PowlVac-ND Vacuum Circuit Breaker

Powered by Safety 01.4IB.77000B PowlVac-ND Vacuum Circuit Breaker Powered by Safety PowlVac-ND Vacuum Circuit Breaker 5kV / 1200A & 2000A / 36kA & 50kA PowlVac-ND Vacuum Circuit Breaker Contact Information Powell Electrical Systems, Inc. powellind.com info@powellind.com

More information

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions DEH 40026 Installation Instructions g ProTrip Conversion Kits For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION GE Conversion Kits are designed for upgrading existing

More information

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers Cutler-Hammer Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE

More information

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs. SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 V ac 42 ka to 0 ka I cu 800 to 6300 A IEC 60947-2 Proven Performance Expanded Capabilities High Withstand Ratings A global source for

More information

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use. Instruction Bulletin Retain for future use. MASTERCLAD Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class 6055 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully

More information

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) RG H ZG E C Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 46-5480 www.cmafh.com Selection This information is presented only as an aid to understanding catalog numbers.

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

Low Voltage Switchgear

Low Voltage Switchgear Low Voltage Switchgear Magnum DS Switchgear.1 Cross-Reference......................................... Product Description....................................... Application Description....................................

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units -1 1 Amperes July 07 Product Selection Table -191. s, H and C Thermal-Magnetic Circuit s with Interchangeable Trip Units Maximum Continuous Ampere at 40 C 2-Pole 0 0 3-Pole 0 0 4-Pole 0 0 Magnetic trip

More information

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order

Detail Bill of Material Page 1 of 2 Project Name: Arc Eng Exposition Negotiation No: LAEC0706X6K1 General Order Detail Bill of Material Page 1 of 2 Project Name: Negotiation No: LAEC0706X6K1 General Order Alternate No: 0000 No: Item No. Qty Product Description 1 Pow-R-Line C Switchboard, Front Access/ Front and

More information

PowlVac Type PV STD/CDR Vacuum Circuit Breaker

PowlVac Type PV STD/CDR Vacuum Circuit Breaker Instructions PowlVac Type PV STD/CDR Vacuum Circuit Breaker Installation Maintenance Renewal Parts POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900

More information

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers

Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers Supersedes IL 33-GDC-5 Dated 07/10 Digitrip Retrofit System for the General Electric AKR 6D/7D-30/50 and AKRT 6D/7D-50 Series Breakers Digitrip Retrofit System for the General Electric AKR Digitrip Retrofit

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter Operation, and Maintenance of the Instruction Bulletin Read and understand these instructions before attempting any installation, operation, or maintenance of the. This equipment shall be installed and

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers

More information

Cutler-Hammer INSTRUCTIONS FOR MAGNUM DS METAL-ENCLOSED LOW-VOLTAGE SWITCHGEAR ASSEMBLIES WITH MAGNUM DS BREAKERS IB E

Cutler-Hammer INSTRUCTIONS FOR MAGNUM DS METAL-ENCLOSED LOW-VOLTAGE SWITCHGEAR ASSEMBLIES WITH MAGNUM DS BREAKERS IB E Cutler-Hammer INSTRUCTIONS FOR MAGNUM DS METAL-ENCLOSED LOW-VOLTAGE SWITCHGEAR ASSEMBLIES WITH MAGNUM DS BREAKERS Read and understand these instructions before attempting to unpack, assemble, operate or

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t ) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t ) FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Masterpact NW DC Circuit Breakers

Masterpact NW DC Circuit Breakers Masterpact NW DC Circuit Breakers Catalog 0613CT0501 R06/15 2015 Class 0613 CONTENTS Description............................................. Page General Information..........................................

More information

Vacuum Circuit Breaker Type VAD-3

Vacuum Circuit Breaker Type VAD-3 Instruction Bulletin Bulletin 6055-11 Vacuum Circuit Breaker Type VAD-3 4.76 kv, 29 ka (250 MVA) 4.76 kv, 41 ka (350 MVA) 8.25 kv, 33 ka (500 MVA) 15.0 kv, 18 ka (500 MVA) 15.0 kv, 28 ka (750 MVA) 15,0

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

MASTERCLAD Metal-Clad Indoor Switchgear

MASTERCLAD Metal-Clad Indoor Switchgear Instruction Bulletin 6055-30 MASTERCLAD Metal-Clad Indoor Switchgear 4.76 15.0 kv Series 5 With Type VR Vacuum Circuit Breakers Class 6055 MASTERCLAD Metal-Clad Indoor Switchgear Bulletin 6055-30 SQUARE

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information