Critical Power Switchboards. Selection and Application Guide
|
|
- Milton Waters
- 6 years ago
- Views:
Transcription
1 Selection and Application Guide
2 Siemens RCIII (rear connected) switchboards utilizing Siemens Type SB Encased Breakers are a perfect solution for your critical power distribution needs. Whether your installation is a data processing center, telecommunications, health care or educational facility, Siemens RCIII switchboards and SB Encased Breakers can satisfy all your power distribution equipment needs and will provide maximum power reliability. Meets UL 891 and NEMA PB-2 Switchboard Standards Individually Mounted Devices Stationary and Drawout Mount Breakers Up to Three Levels of Through Bus Optional 30 Cycle Short Time Bus Bracing Optional ACCESS TM Power Monitoring and Communication Short Circuit Current Ratings up to 200kA Incoming Service up to 6000 Amp Tin Plated Aluminum or Silver Plated Copper Bus Indoor or Outdoor Enclosures Up to 6 Breakers Can Be Mounted in the Same Vertical Stack Compartmentalization Available Separate Breaker, Bus and Cable Compartments SB Encased Breakers Meet All UL 489 and IEC Standards 1
3 Type SB Encased Systems Breakers Front View of Incoming Service and Distribution Feeder Section Rear View of Bus and Cable Compartment of Feeder System Barriers Installed Rear View of Bus and Cable Compartment of Feeder System Barriers Removed Type SB Encased Systems Breakers Maximum Interrupting Capacity Short Time In Symmetrical RMS Amperes Ratings In Maximum Available For Voltage AC Symmetrical Ampere Amperage Breaker RMS Amperes Rating Range Type 240V 480V 600V (30 Cycles) , , SBA 65,000 65, , , , , SBS 100, ,000 35, ,000 85, , ,000 SBH 200, , , , ,000 2
4 SB Encased Systems Breakers Shunt Trip Auxiliary Switches, up to 6 N.O./ N.C. Undervoltage Release Electronic Bell Alarm Module Electric Charging Motor Operator with Electronic Controller Integral Local Electric Close Option Integral Kirk-Key Interlock on SB Close Blocking Device Trip Padlock Device Position Padlock Device (Drawout) Cell Switches, 4 N.O./ N.C. (Mounted on Drawout Stationary Element) Automatic Safety Shutters Kirk-Key Provision (Mounted on Drawout Stationary Element) Mechanical Interlock Capacitor Trip Device Remote Indication / Relay Panel Auxiliary Power Module (for benchtesting trip unit) TS 31 Universal Test Set Available Rating Plugs Frame Ampere Rating (I n ) Rating Plug Amperes (I r ) ,225,250,300,350, , 450, 500, 600, 700, , 700, 800, 1000, , 1000, 1200, , 1200, 1600, , 2000, , 2000, 2500, 3000, , 2500, 3000, 3200, , 3000, 3200, 4000, 5000 SB Breaker Trip Unit Ratings (I r = Rating Plug Value; I n = Frame Ampere Rating) Current Setting (x Current Rating P/US).5,.6,.65,.7,.75,.8,.85,.9,.95, 1.0 Long Time Pickup (T) Delay (Sec.) 2.5, 5.5, 8, 10, 14, 17, 21, 25, 30 Short Time Frame Amp Rating A A (S) Pick up (xl r ) 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8, 9 1.5, 2, 2.5, 3, 4, 5, 6, 7, 8 Delay (I 2 t) out.07,.1,.15,.2,.3 seconds Delay (I 2 t) in.07,.1,.15,.2,.3 seconds Adjustable Frame Amp Rating A A Instantaneous Pick-up (I) Pick up (xl r ) 25kA 1.5, 2, 3, 4, 5, 6, 7, 8, 9, 10 Instantaneous Frame Amp Rating A 2000A 3200A A Override Fixed 25kA 35kA 50kA 65kA Ground Frame Amp Rating I n Available Setting (I n) Fault 400, 800, , 25, 30, 40, 50, 60, 70, 80, 90, 100 (G) , 26, 32, 38, 44, 50, 56, 62, 68, , 23, 27, 30, 35, 40, 45, 50, 55, , 23, 26, 29, 32, 35, 38, 41, 44, , 21, 23, 25, 27, 29, 31, 33, 35, , 21, 22, 23, 24, 25, 26, 27, 28, Setting fixed at 1200A Delay (Fixed).1,.2,.3,.4,.5 = I n Delay (I2t).1,.2,.3,.4,.5 = I n Current equal to 6 times I r. Current equal to 8 times I r..500 seconds maximum. No trip point setting exceeds 1200 amperes. SB Trip Unit Replaceable Rating Plugs Adjustable From % of Frame Rating Continuous Self-Diagnostic Watchdog Integral Test Functions for Phase and Ground Fault (Trip and No-Trip Tests) External Power Source Allows Bench Testing of Stand-Alone Trip Unit Plug-in Display Modules for Current and Energy Display Capabilities Long Time Continuous Current Setting Long Time Delay Band Setting Static Trip III Trip Unit Short Time Pickup Setting Short Time Delay Band Setting Instantaneous Pickup Setting Integral LED Trip Indicators Full Communications Capability Via Siemens ACCESS Network LCD Target Thermal Memory Switch Short Time I 2 t Ramp Switch Zone Interlock Switch SB-EC Trip Unit Zone Interlocking Input/Output and Future Options LCD Display Key Pad Test Connector Serial Port System Check Leds System Status Leds 3
5 Siemens ACCESS Electrical Distribution Communication System centrally monitors and controls an entire electrical distribution system. Engineers, accountants, executives, and technicians can access an almost limitless stream of data for troubleshooting, early warning alarms, power quality studies, preventive maintenance, cost allocation, and facilities planning. ACCESS adds a new dimension to managing energyintensive facilities, allowing identification and correction of potential problems before they cause damage, waste, injury, or downtime. System Overview ACCESS enables users to connect new or retrofitted Siemens Intelligent metering and protective devices in switchboards, switchgear, and motor control centers via a twisted pair of wires, in order to access critical electrical operating information. ACCESS provides a graphical user interface for viewing and reporting information such as real-time, historical, and min/max data on a desktop computer or field-installed industrial computer. The field device network uses an industrystandard RS-485 twisted pair, which has galvanic isolation of up to 500 volts. Siemens SEAbus communications protocol is utilized on the RS-485 high speed LAN. SEAbus is an open protocol with complete documentation allowing users to integrate Siemens devices directly into other customized communications systems. Siemens ACCESS Electrical Distribution Communications System meets ANSI/ IEEE C , C , and RFI / EMI 6241 specifications. Primary Functions Reducing costly down time by identifying system problems well in advance of tripping. Providing data for more efficient allocation of power usage cost, and providing accurate verification of utility billing. Identifying and controlling peak power demand. Allowing actions such as load shedding, changes in billing structure from the utility, or other remedial steps to minimize power cost. Providing data to plan substation expansion needs, such as the ability to know steady-state and momentary percentage of capacity for all breakers and transformers. Providing data that allows the user to analyze the quality of power, such as harmonics and disturbances (surges and sags), and this data can be used for diagnostics, reporting, or other tracking purposes. ACCESS-Compatible Devices From Siemens Look For This Symbol... Table 1.1 below lists Siemens devices which are ACCESS "savvy". Table 1.1 ACCESS Field Level Device Cross Reference Category Protective Relays and Trip Units Metering Motor Protection and Control Relays I/O Devices Monitoring Devices This symbol will appear with products which tie into the ACCESS system. Model Static Trip IIIC/IIICP/IIICPX - LV Power Breakers Type SB Encased Systems Breakers SB Energy Communicating Trip Unit Sensitrip III Molded Case Circuit Breakers ISGS Protective Relay 9230, 4300, 9240, 9300, 9330, 4700, 4720, 9500 and 9700 Power Meters SAMMS-LV TM SAMMS-MV TM S7-I/O Power Monitor Panel, Local Display Unit (LDU) 4
6 Dimensional Information Main & Feeder Breakers 58 (1473) Standard Depth 60 (1524) & 68 (1727) Optional Depth 3 (76) W2 Conduit Area Top or Bottom 3 (76) 15 (381) 2.5 (64) 40.5 (1029) 90 (2286) 84 (2133) Available Breaker Unit Space W1 Dimensions shown in inches and millimeters ( ). Required Breaker Breaker Frame Size W1 W2 Unit Space Frame Size 1 (400/800/1200 Amp) 25 (635) 19 (483) 14 (356) [1] Frame Size 2 (1600/2000 Amp) 25 (635) 19 (483) 21 (533) [1] Frame Size 3 (2500/3200 Amp) 38 (965) [3] 32 (813) 42 (1067) [2] Frame Size 4 (4000/5000 Amp) 38 (965) [3] 32 (813) 42 (1067)[2] Only one breaker per section can be energized. [1] Frame Size 1 breakers and Frame Size 2 breakers can be mixed in the same stack but each frame size requires 42" of unit space whether it is totally used or not. [2] Can not be mixed with Frame Size 1 or Frame Size 2 breakers in the same stack. [3] Optional 34 inch (864 mm) wide is available. 5
7 Siemens Energy & Automation, Inc. Power Distribution Infrastructure Division 3333 Old Milton Parkway For Nearest Sales Office For Product Information Alpharetta, GA Siemens Energy & Automation, Inc. ACCESS TM, SAMMS-LV TM, SAMMS-MV TM, Static Trip and Sensitrip Order No. SWSA Siemens is a registered trademark of Siemens AG are registered trademarks of Siemens Energy & Automation, Inc. New Specifications are subject to change without notice. 5M0201B&A Printed in U.S.A.
Power Break II Switchboard
Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationwww. ElectricalPartManuals. com Section 13 Switchgear Low Voltage
Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationA. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.
16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to
More informationSECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.
SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationMaxSG Low Voltage Switchgear
Low Voltage Products & Systems Automation Technology MaxSG Low Voltage Switchgear ABB Automation Technologies MaxSG ABB Slide 2 June 2009 Product verview Key Features and Benefits Construction nstrumentation
More informationProduct Specification Sheet #3LD2.1
Product Specification Sheet #3LD2.1 Enclosed Non-Fusible Rotary Disconnect Switch 16 30 Amp, Type 12K Industrial and Type 4X Non-Metallic Enclosures General Information and Horsepower Ratings Shipping
More informationLow Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear
13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of
More informationSWITCHGEAR DIVISION PRODUCT PROFILES
SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,
More informationUNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation
Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers
More informationVL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS
VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................
More informationSpecialty Service Entrance Switchboards. Selection and Application Guide
Specialty Service Entrance Switchboards Selection and Application Guide Power! As the heart of every business complex it has to be reliable. As part of your business, it has to be economical too.you get
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationSB Encased Systems Breakers, Trip Units and Accessories. Selection and Application Guide October 1, 1999
SB Encased Systems Breakers, Trip Units and Accessories Selection and Application Guide October 1, 1999 Table of Contents General Information 2-3 Description Stationary and Moveable Drawout Elements 4
More informationMedium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General
13 SWITCHGEAR Medium Voltage Equipment -1 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General Overview Features Siemens, 7, 1 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear
More informationQED-6 Rear Connected Switchboards
QED-6 Rear Connected Switchboards with Masterpact NW & NT and PowerPact H-, J- & D-Frame Circuit Breakers Square D QED-6 rear connected low voltage switchboards are proven, reliable and durable. These
More informationDIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS
DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection
More information1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.
SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.
More informationDescriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications
Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter
More informationSolar Power Switchgear & Energy Storage Renewable Energy Systems
7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationSB Encased Systems Breakers, Trip Units and Accessories. Pricing Guide Effective: September 9, 2002 (Consult Siemens for Pricing after 10/01/03)
SB Encased Systems Breakers, Trip Units and Accessories Pricing Guide Effective: September 9, 2002 (Consult Siemens for Pricing after 10/01/03) Table of Contents How to Order SB Encased Systems Breakers
More informationPOWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers
POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers Class 6037 CONTENTS Schneider Electric Brands Description Page Product Description..................................................
More informationA. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.
SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationA. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.
DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION 23 90 71 PART 1 GENERAL 1.01 DESCRIPTION A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings
More informationGE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1
GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More informationATLV MaxSG. Low Voltage Metal Enclosed Switchgear
ATLV MaxSG Low Voltage Metal Enclosed Switchgear ABB, INC. Product General Description MaxSG Switchgear ABB MaxSG switchgear is a further continuation in the development of innovative products from ABB,
More informationWL Low Voltage Metal-Enclosed Switchgear. Selection and Application Guide.
WL Low Voltage Metal-Enclosed Switchgear Selection and Application Guide www.sea.siemens.com/switchgear 3 Table of Contents General Information...............................................................................................
More informationAir Circuit Breakers
Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationTYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS
om.c ww w.e lec tri ca lp ar tm an ua ls TYPES DS II AND DSL II METAL ENCLOSED LOW VOLTAGE POWER CIRCUIT BREAKERS Proven Technology with the Enhancements and Additional Ratings Our Customers Asked For
More informationSIEMENS. Microprocessor-Based Tripping System. Static lrip III. www. ElectricalPartManuals. com
SIEMENS Microprocessor-Based Tripping System Static lrip III A Revolutionary Advance In Equipment Protection. Siemens. a pioneer in electronics technology, now provides the highest level of equipment monitoring
More information16.13 Unit Substation to 15kV Construction Standards Page 1 of 7
Construction Standards Page 1 of 7.1 General.1 New buildings are to be provided with an indoor unit substation designed to accept 15kV and 25kV primary voltages, however, the primary voltage connected
More informationAir Circuit Breakers
Siemens AG 204 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23
More informationDesign Standard. Purpose: Design Standard:
Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard
More informationControlled Power HSN High Speed DC Circuit Breakers
Controlled Power HSN High Speed DC Circuit Breakers Each CP Type HSN circuit breaker unit can consist of either a wheeled truck and housing or be panel mounted. The circuit breaker can be mounted on the
More informationIndividual breakers in separate enclosures can be applied in low voltage distribution systems through 600 volts Ac, 50/60 Hertz.
Page 2 Introduction The Westinghouse Systems Pow-R Breaker, the worlds first encased power breaker, is not just an extension of existing technology. It represents the biggest breakthrough in circuit protection
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationIN2 Enclosed Switches and Circuit Breakers
Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals
More informationModel ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase
Model ESV Uninterruptible Power System 1.5 KVA/KW - 14.0 KVA/KW Single Phase 1.0 General General Specification This specification describes the features and design of an on-line, dual conversion, uninterruptible
More informationSafeGear TM Motor Control Center Arc resistant metal-clad construction
SafeGear TM Motor Control Center Arc resistant metal-clad construction Contents Description 2 SafeGear TM MCC applications 3 Electrical features 3 Standards 3 Standard service conditions 4 HCV vacuum contactor
More informationWARREN COUNTY, N.Y. M/E REFERENCE
SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE
More informationWL Low Voltage Metal-Enclosed Switchgear
www.usa.siemens.com/switchgear WL Low Voltage Metal-Enclosed Switchgear Selection and Application Guide Answers for industry. Table of Contents General Information... 2 Construction Details... 3-5 WL
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationC1000 Series Automatic Cap Bank
C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution
More informationSIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC
c c SIEMENS Series 8100oT Vacuum Controllers Bulletin CC3802-02 Technological Development Vacuum technology has developed rapidly in recent years and is becoming widely accepted for medium voltage motor
More informationSelection and application guide
Selection and application guide Integrated Power Systems Switchboards www.usa.siemens.com/switchboards Integrated Power Systems Switchboards Contents General Product Information 2-3 General Layout Information
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationSURE TRIP RETRO KITS
RMS CURRENT MEASUREMENT with SURE TRIP RETRO KITS Circuit Breaker Solid State Controls with SURE TRIP LOGIC The Sure Trip Solid State Tripping Systems Have Been Designed, Tested And Produced To all Applicable
More informationA. This section includes unit capacitors for power factor correction.
PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02
More informationSECTION MOTORS AND VARIABLE FREQUENCY DRIVES
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Related Sections: 1. Section 15050 - Basic Mechanical Requirements. 2. Section 15051 - Motors. 3. Section 15185 - Hydronic Pumps. 4. Section 15625 - Centrifugal
More informationDesign Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak
Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More informationSafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure
2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear
More informationOTPC-SE Service entrance transfer switch open transition
Specification sheet OTPC-SE Service entrance transfer switch open transition 40 1000 amp Description OTPC service entrance transfer switches are designed for operation and switching of electrical loads
More informationSwitchgear and Distribution Systems for Engineers and Technicians
Switchgear and Distribution Systems for Engineers and Technicians WHAT YOU WILL LEARN: How to identify typical characteristics of an industrial distribution system Become familiar with the main components
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationTable Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.
-174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40
More information6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton
Advances in technology to address safety Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton 1 Advances in technology could mean use existing technology & back to basics Advances in safety are
More informationSURE-TRIP OEM RELACEMENT TRIP UNIT
RMS CURRENT MEASUREMENT with SURE-TRIP OEM RELACEMENT TRIP UNIT Update Circuit Breaker Solid State Controls with SURE-TRIP LOGIC The SURE-TRIP Solid State Tripping Systems Have Been Designed, Tested And
More informationMar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)
2101 Commonwealth Blvd, Suite B Ann Arbor, MI 48105-5759 www.med.umich.edu/facilities/plan/ 263010-H: SUPPLEMENTAL PARALLELING GEAR (16315-H) Related Sections Basis Guideline: N/A For an explanation of
More informationA. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.
16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 28 16 An optional
More informationMotorpact Medium Voltage Motor Controller. Innovative solutions that deliver high performance and reliability
Motorpact Medium Voltage Motor Controller Innovative solutions that deliver high performance and reliability A tradition of trusted innovation For one hundred years, the Square D brand has provided leading
More informationType SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.
Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings
More informationMagnum IEC Low Voltage Air Circuit Breakers
Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven
More informationA. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.
PART 1: GENERAL PART I: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other
More information2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G
. NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationMULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers
IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when
More informationEnclosed Rotary Switch Product Specification Sheets Table of Contents
Enclosed Rotary Switch Product Specification Sheets Table of Contents Catalog No. Sheet No. Order No. SSSS-ENRSW-1005 HNF3020CJ HNF3020CJE HNF3030CJ HNF3030CJE HNF3030CX HNF3060CJ HNF3060CJE HNF3060CX
More informationGE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc
GE Industrial Solutions User/Installation Manual for 4.76kV -15kV SecoBloc Index General Scope...3 Standards...3 Operating conditions...3 Technical specification...3 Basic structure Features...4 Operation...4
More informationBGE STRATEGIC CUSTOMER ENGINEERING
TABLE OF CONTENTS 1. GENERAL.. 2 2. BGE SUPPLY FEEDER.. 4 3. SWITCHGEAR ENCLOSURE AND ASSEMBLY... 5 4. SWITCHGEAR MANUFACTURERS.. 8 5. CIRCUIT BREAKER.. 8 6. SWITCHGEAR EQUIPMENT.... 10 7. MAIN AND GROUND
More informationOTEC Transfer switch open transition
Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator
More informationAT EVO SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY EVO AT Series Battery Charger is HindlePower s next generation SCR-based utility battery charger. This evolutionary product is revolutionary in its design and operation
More informationSECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes metal-enclosed,
More informationGenerator/Loadbank Quick Connection Tap Box
/ Generator/Loadbank Quick Connection Tap Box WM2-Series Generator/Loadbank Quick Connection Solutions Brochure www.apt-power.com 433 N. 36 th Street Lafayette, IN 47905 (765) 446-2343 ALN: 517 Rev. 01
More informationMV Metalclad Switchgear 4760V-15000V 20KA-63KA. AC Power Circuit Breaker Rating Structure. Test Procedures for Power Circuit Breakers
Contents Key Features and Benefits Codes and Standards Value Addition by Application of PVAC-E GE Components Inside Design Features on PVAC-E Switchgear PVAC-E Switchgear Configuration PVAC-E Switchgear
More informationSpecification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers
Specification Guide for RMAX Direct Replacement AC Low Voltage Power Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards... 3 3.0 Supplier Qualifications... 3 4.0 Mechanical and
More informationSECTION 16426B. RELATED SECTIONS Section 16671A Transient Voltage Surge Suppression Section Microprocessor-Based Metering Equipment
METAL-ENCLOSED DRAWOUT SWITCHGEAR (DSLII) LOW VOLTAGE PART 1 GENERAL 1.01 1.02 1.03 1.04 SCOPE The Contractor shall furnish and install, where indicated on the drawings, a deadfront type, low voltage metal-enclosed
More information1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".
SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,
More informationMedium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU
Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal
More informationSwitchgear. Low Voltage
January 2001 Vol. 1, Ref. No. [0923] -1 Low Voltage Switchgear Contents Description Page Magnum DS Metal-Enclosed Product Description........................................... -2 Application Description........................................
More information.1 Low Voltage Switchgear Magnum DS Switchgear with Molded Case Circuit Breaker Feeder Section Cross-Reference Eaton s Electrical Sector has an organi
Low Voltage Switchgear Magnum DS Switchgear.1 Cross-Reference................................................ 102 Product Description............................................. 102 Application Description...........................................
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements
More informationTradition. Technology. Innovation.
Tradition. Technology. Innovation. 2 Tradition. Technology. Innovation. 50433 IEM CorpBror1.indd 2 4/3/15 2:41 PM Today, IEM has expanded beyond Silicon Valley to supply specialized electrical equipment
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationSECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2
SECTION 1. 600V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2 Soft Starters SECTION 2. LIQUID COOLED VFD I 3 Liquid Cooled
More informationSoftstarters. Softstarters Type SSM Medium voltage ,800V 1
Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum
More informationContents. Page INTRODUCTION Power/Vac GUIDE FORM SPECIFICATION thru
Contents Page INTRODUCTION... 10-2 Power/Vac GUIDE FORM SPECIFICATION... 10-2 thru 10-12 10-1 Power/Vac Guide Form Specifications Guide Form Specifications INTRODUCTION Upon completion of the one-line
More information16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12
16kA Solid Dielectric, Triple Option Reclosers Providing electronic overcurrent protection for single or three phase operation on systems rated through 27kV, 630A continuous current, 16kA symmetrical interrupting
More information