A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Size: px
Start display at page:

Download "A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein."

Transcription

1 16475 OVERCURRENT PROTECTIVE DEVICES ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: An optional keynote to the Drawings follows major product titles, for A/Es using National CAD Standard. ************************************************************************************************************* PART 1 GENERAL 1.1 SUMMARY A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein. 1.2 Related Sections: Switchboards Disconnect Switches Panelboards Motor Starters Motor Control Centers. 1.3 SYSTEM DESCRIPTION A. Performance Requirements: Materials shall be listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 1.4 SUBMITTALS A. Submit properly identified manufacturer's literature, product data, and technical data before starting work. 1.5 QUALITY ASSURANCE A. NEMA AB (National Electrical Manufacturers Association) Molded Case Circuit Breakers and Molded Case Switches. B. UL 489 (Underwriters Laboratories Inc.) Molded Case Circuit Breaker Enclosures. C. UL943 Standard for Ground Fault Circuit Interrupters. D. CSA C22.2 No. 5.1 M91 (Canadian Standard Association) Molded Case Circuit Breakers. E. Federal Specification W- C 375b/GEN Circuit Breakers, Molded Case; Branch Circuit and Services. F. National Fire Protection Association NFPA 70 (National Electric Code). G. Fuses shall comply with NEMA FUI and ANSI C Project Name M-DCPS MASTER May 2016 Project No. SPECIFICATION GUIDELINES

2 PART 2 PRODUCTS 2.1 MANUFACTURERS A. Circuit Breakers: 1. GE. 2. Siemens. 3. Square D. 4. Eaton Corp. B. Fuses: 1. Bussman Manufacturing. 2. Gould-Shawmut Company. 3. CEFCO. 4. Littelfuse, Inc. 2.2 EQUIPMENT A. Circuit Breakers: 1. Conform to Federal Specification W-C-375a and NEMA Standard AB-1, unless indicated otherwise. 2. Lugs and terminals: UL approved for copper-aluminum. 3. Accessories: 120 volt. 4. Each circuit breaker shall be provided with a trip unit for each pole with elements providing inverse time delay under overload conditions and instantaneous magnetic trip for short circuit protection, unless indicated as non-automatic. Trip elements shall operate a common trip bar to open all elements. 5. All circuit breakers shall be bolt-on type, consisting of the number of poles and ampere ratings as noted on the drawings. 6. Two and three pole breakers shall be of the common trip type. 7. Circuit breakers shall be a circuit interrupting device operating both manually for normal switching functions and automatically under overload and short circuit conditions, while providing circuit and self-protection when applied in its ratings. Provide at voltage, phase, and amps indicated, with symmetrical amperes interrupting rating to be equal or larger than that shown on drawings. Control and signaling function may be incorporated by use of accessories. 8. Operating mechanism shall be entirely trip-free so contacts cannot be held close against an abnormal over-current or short circuit condition. 9. Operating handle of circuit breaker shall open and close all poles of a multi-pole breaker simultaneously. Circuit breakers shall meet applicable NEMA AB-1 and have UL label. 10. Ampere rating shall be clearly visible. Contacts shall be of non-welding silver alloy. Circuit breakers to be used in switchboards, lighting and power panelboards, distribution panelboards and individually enclosed shall be 1, 2, or 3 poles as indicated on drawings. B. Molded Case Circuit Breakers Characteristics - General: Project Name M-DCPS MASTER May 2016 Project No. SPECIFICATION GUIDELINES

3 1. Circuit Breakers shall be constructed using glass reinforced insulating material. Current carrying components shall be completely isolated from the handle and the accessory mounting area. 2. Circuit breakers shall have an over center, trip free, toggle operating mechanism which will provide quick make, quick break contact action. 3. The circuit breaker handle shall reside in a tripped position between on and off to provide local trip indication. Circuit breaker escutcheon shall be clearly marked on and off in addition to providing International I/O markings. 4. The maximum ampere as established by a NRTL, or other certification standards, with applicable voltage systems and corresponding interrupting ratings, shall be clearly marked on face of circuit breaker. 5. Circuit breakers shall be factory sealed with a hologram quality mark and shall have date code on face of circuit breaker. 6. Circuit breaker combinations for series connected interrupting ratings shall be listed by a NRTL as a recognized component combinations. Any series rated combination used shall be marked on the end use equipment along with the statement Caution Series Rated System A Available. Identical Replacement Component Required. 7. Circuit breakers shall be equipped with NRTL listed electrical accessories as noted on the electrical drawings. Circuit breaker handle accessories shall provide provisions for locking handle in the On and Off position. 8. Circuit breakers shall be NRTL listed for reverse connection without restrictive line and load markings and be suitable for mounting in any position. 9. Molded case circuit breakers shall be bolt-on type, mounted in lighting and power panelboards and individually enclosed units. 10. Molded case circuit breakers shall be quick-make, quick-break action. 11. Molded case circuit breakers for panelboards shall have a short circuit current rating based on the coordination and short circuit study or the following minimum symmetrical ampere interrupting capacities (RMS): a. 120 volts: 10,000 SAIC power panelboards (miminum). b. 277 volts: 14,000 SAIC lighting panelboards (minimum). c. 277/480 volts: Up to 50,000 SAIC distribution panelboards, or as shown on drawings. 12. Each molded case circuit breaker shall have a thermal magnetic trip device, with common tripping for all poles, and with trip ratings as shown on drawings. C. Electronic Trip Circuit Breakers With Standard Function Trip System 2000 amp maximum 1. Circuit breaker trip system shall be a micro compressor based true rms sensing design with sensing accuracy through the thirteenth (13 th ) harmonic. Sensor ampere ratings shall be as indicated on the associated electrical drawings. 2. The integral trip system shall be independent of any external power source and shall contain no less than industrial grade electronic components. 3. The ampere rating of the circuit breaker shall be determined by the combination of an interchangeable rating plug, the sensor size and the long time pickup adjustment on the circuit breaker. The sensor size, rating plug and the adjustment positions shall be clearly marked on the face of the circuit breaker. Circuit breakers shall be listed by a NRTL to carry 80% or 100% (if working as a service entrance main breaker) of their Project No. SPECIFICATION GUIDELINES

4 ampere rating continuously as specified or designed on the associated electrical drawings. 4. The following time/ current response adjustments shall be provided. Each adjustment shall have discrete settings and shall be independent of all other adjustments. a. Long Time Pickup Instantaneous Pickup b. Long Time Delay (Ground Fault Pickup) c. Short Time Pickup (Ground Fault Delay (I2t OUT only)) d. Short Time Delay e. Ground Fault Pickup {Service Entrance Main if required or designed.} f. Ground Fault Pickup {Service Entrance Main if required or designed.} 5. A means to seal the trip unit adjustments in accordance with NEC Section 240-6(b) shall be provided. 6. Local visual trip indication for overload, short circuit and ground fault trip occurrences shall be provided. 7. Long Time Pickup indication to signal when loading approaches or exceeds the adjusted ampere rating of the circuit breaker shall be provided. 8. Circuit breaker trip system shall be equipped with an externally accessible test port for use with a Universal Test Set. Disassembly of the circuit breaker shall not be required for testing. Test set shall be capable of verifying the operation of all trip functions with or without tripping the circuit breaker. D. Fuses: 1. Provide rejection fuses for fusible equipment regardless of which trade has furnished such equipment. 2. The time-current characteristic and ratings shall assure positive selective coordination. 3. All fuses: current limiting and have an interrupting capacity of at least 200,000 amperes RMS symmetrical. 4. The time-current characteristics and ratings shall be set in such a way that positive selective coordination is assured. 5. Coordination and current limitation for the protection of each part of the electrical system must be designed around the type and class and manufacturer selected for that type and class. 6. Fuses, 601 amperes and larger, shall comply with UL Class L standard and be Shawmut Form 480 "Amp-Trap" or Bussman "Hi Cap". 7. Fuses, 600 amperes and lower, where applied to general feeder and branch circuit protection, shall comply with UL Class RKl standards and be Shawmut dual element "Amp- Trap" or Bussman "Low Peak" Limitron. 8. Dual element fuses shall have low resistance and relatively low operating temperatures. Fuses shall be provided with thermal protection against damage from poor contact. Fuse shall open when temperature at thermal cutout reaches 280 degrees F., preventing damage to clips and switches before fuse opens. They shall combine high interrupting capacity (200,000 ampere RMS symmetrical) with time delay, holding 500 percent load for a minimum of 10 seconds. 9. Individual motor circuit fuses shall be sized at approximately 150 percent of motor full load current. Fuses, below 600 amperes shall comply with UL Class RK1, time delay, dual element standardsand be Gould-Shawmut "Amp-Trap" or Bussman Type LPN- Project No. SPECIFICATION GUIDELINES

5 RK. Fuses 601 amperes and larger, shall comply with UL Class L standards and be Gould-Shawmut Form 480 "Amp-Trap" or Bussman Type KRP-C. 10. Provide 10 percent spares (minimum of three) of each size and type of fuses furnished. Spare fuses shall be placed in a wall-mounted cabinet located in the main electric room. PART 3 EXECUTION 3.1 INSPECTION A. Do not proceed with the work of this section until conditions detrimental to the proper and timely completion of the work have been corrected in an acceptable manner. 3.2 INSTALLATION A. Install all circuit breakers and fuses where indicated on drawings, where required by NEC or other applicable codes and regulations, and in accordance to manufacturer's recommendations and accepted submittals. Special attention shall be given to air conditioning equipment. B. Two and three pole breakers must be true two and three pole breakers. 1. Do not combine single pole breakers with common handle connection to meet multiple pole breaker requirements. C. Label circuit breaker enclosures with 1 inch high stenciled letters showing equipment served. D. Circuit breaker pick-up level and time delay settings shall be adjusted to values indicated on the coordination study. END OF SECTION Project No. SPECIFICATION GUIDELINES

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS DIVISION 26 ELECTRICAL SECTION 26 28 19 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install circuit breakers in switchboards, distribution panelboards, and separate enclosures for overcurrent protection

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 21 ENCLOSED SWITCHES AND CIRCUIT BREAKERS SPEC WRITE NOTE: Delete between // // if not applicable to project. Also delete any other item or paragraph not

More information

Quik-Spec Coordination Panelboard Specifications

Quik-Spec Coordination Panelboard Specifications Quik-Spec Coordination Panelboard Specifications 30A - 400A Fusible Panelboards SECTION 26 24 XX (This Specification references CSI MasterFormat 2004) FUSIBLE BRANCH CIRCUIT PANELBOARDS PART 1 1.01 SUMMARY

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

1. The term withstand means the unit will remain in place without separation of any parts from the device when subjected to the seismic forces. SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Fusible switches. 2. Nonfusible switches. 3. Receptacle switches. 4. Shunt trip switches. 5.

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.

More information

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

1. Division 26 Section Elevator Shunt-Trip Fused Disconnect Switches. SECTION 26 28 16 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections,

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

BUSWAY Low Voltage (Pow-R-Flex)

BUSWAY Low Voltage (Pow-R-Flex) BUSWAY LOW VOLTAGE (POW-R-FLEX) PART 1 GENERAL 1.01 1.02 SCOPE The Contractor shall furnish and install the busway system including all necessary fittings, hangers and accessories as specified herein and

More information

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types: SECTION 262913 600 VOLT ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 0 Specification

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

IN2 Enclosed Switches and Circuit Breakers

IN2 Enclosed Switches and Circuit Breakers Illinois Math and Science Academy DigitalCommons@IMSA Project Manuals IN2 2015 IN2 Enclosed Switches and Circuit Breakers Illinois Mathematics and Science Academy Follow this and additional works at: http://digitalcommons.imsa.edu/facility_in2_manuals

More information

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems.

More information

Service Entrance Methods

Service Entrance Methods Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

SECTION DISTRIBUTION AND GROUNDING

SECTION DISTRIBUTION AND GROUNDING SECTION 16400 DISTRIBUTION AND GROUNDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Furnishing and installation of a complete electrical distribution and grounding system. B. Furnish and install motor control

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information

SECTION ELECTRIC DISTRIBUTION

SECTION ELECTRIC DISTRIBUTION SECTION 16400 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary General Conditions and other Division

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System 2004 Specifications CSJ 2121-04-072 SPECIAL SPECIFICATION 5066 Packaged Engine Generator System 1. Description. Furnish and install packaged engine generator system complete with transfer switch and service

More information

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION! PREFACE This publication has been prepared as a guide for Architectural and Engineering (A&E) firms in the preparation of documents for the design and construction of new structures and the remodeling

More information

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards 1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases

More information

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION Specification Number: 26 24 13.20 Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION 26 24 13.20 SWITCHBOARDS (Long) Main Disconnect Group Mounted Fusible

More information

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications Student Resource Building University of California Santa Barbara Clement Fung Lighting Electrical Option APPENDIX E Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection

More information

Applying Interrupting Rating: Circuit Breakers

Applying Interrupting Rating: Circuit Breakers The professional engineer must be qualified by primarily working in the design or maintenance of electrical installations. Documents on the selection shall be stamped and available to all necessary parties.

More information

SECTION ENCLOSED CONTROLLERS

SECTION ENCLOSED CONTROLLERS SECTION 16420 ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Applying Interrupting Rating: Circuit Breakers

Applying Interrupting Rating: Circuit Breakers Series Rating: Protecting Circuit Breakers Generally, a circuit breaker should not be applied where the available shortcircuit current at its line side terminals exceeds the circuit breaker s interrupting

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Devices for Branch Circuits and Feeders

Devices for Branch Circuits and Feeders Devices for Branch Circuits and Feeders Branch Circuit Overcurrent Protective Devices and s Fusible Solutions: When selecting fusible overcurrent protective devices, the type of fuse holder or switch is

More information

Recommended Procedures

Recommended Procedures Selective Coordination Study Recommended Procedures The following steps are recommended when conducting a selective coordination study.. One-Line Diagram Obtain the electrical system one-line diagram that

More information

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Solar Power Switchgear & Energy Storage Renewable Energy Systems 7 Solar Power Switchgear & Energy Storage Renewable Energy Systems - Solution Brochure www.apt-power.com 433 N. 36 th Street PROVIDING A COMPREHENSIVE Lafayette, IN 47905 www.apt-power.com 433 APPROACH

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950.

Molded Case Circuit Breakers Amperes LSIA. LSIG Catalog Number 3-Pole Standard Interrupting Capacity 600V AC Rated V AC 13,950. Vol. 1, Ref. No. [0559] - Amperes M-Frame 12-93 % Rated Digitrip OPTSM s with interchangeable Rating Plugs Order as individual components: Frame (which includes Trip Unit), Rating Plug, Terminals. Table

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

General Purpose US Fuses

General Purpose US Fuses SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides

More information

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

Specification made simple for selective coordination in a compact size

Specification made simple for selective coordination in a compact size Quik-Spec family of circuit protection solutions BUSSMANN Specification made simple for selective coordination in a compact size SERIES The Quik-Spec Coordination Panelboard (QSCP) simplifies selective

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES TSEWG TP-11: UFC 3-500-10N BEST PRACTICES UFC 3-500-10N was developed by NAVFAC and was used as the starting point for the tri-services development of UFC 3-500-10, Design: Electrical Engineering. UFC

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Fused Coordination Panelboard

Fused Coordination Panelboard Fused Coordination Panelboard SOLUTIONS GUIDE SOLUTIONS GUIDE Branch Circuit Protection Introducing Mersen s Fused Coordination Panelboard Selective Coordination is required in several locations as defined

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001

Cutler-Hammer. Molded Case Circuit Breakers Amperes F-Frame. January 2001 2-22 0-225 Amperes F-Frame Cutler-Hammer January 200 Vol.,Ref. 2-2 Product Line Overview January 200 Vol., Ref. No. [0468] 2 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES LENRK/LESRK CLASS RK Catalog Number LENRK (. - 0A) 50 Volts AC or Less Catalog Number LESRK (.5-0A) 0 Volts AC or Less S LENRK 50V 0..5 75 0..5 5 0..5 9 50 5 0.5 50 0.. 70 0 0..5 5 0 50 7.5 90 0..5 0 50.

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. Product Selection January 2001 Vol. 1, Ref. No ) J-Frame Vol. 1, Ref. No. 10499) Product Selection Table 12-56. Types 12-33 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E. MOLDED CASE CIRCUIT BREAKER BASICS David Castor, P.E. History of MCCBs 1904 - Cutter Manufacturing Co., Philadelphia, produces circuit breakers. They called it the Inverse Time Element breaker, or I-T-E

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes January J-Frame 12-34 70 - Amperes Cutler-Hammer Vol. 12-2 Product Line Overview Vol. 1, Ref. No. [0468] 12 Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection

More information

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES SERIES E-RATED/MEDIUM VOLTAGE FUSES 5kV, 8kV and 15.5kV FERRULE MOUNTED FUSES Amp-trap E-rated 5kV 8kV and 15kV fuses have 2 or 3 inch diameter barrels with ferrules and are mounted in spring reinforced

More information

Cutler-Hammer. Molded Case Circuit Breakers Amperes. -" Product Selection M-Frame

Cutler-Hammer. Molded Case Circuit Breakers Amperes. - Product Selection M-Frame Cutler-Hammer Vol. 1, Ref. No. [0537] 300-800 Amperes 12-71 -" Product Selection Table 12-114. Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Maximum Continuous Ampere

More information

Selective Coordination Enforcement:

Selective Coordination Enforcement: Selective Coordination Enforcement: Overcurrent Protective Device Basics by Tim Crnko The Basics of Selective Coordination Merely having a higher ampere overcurrent protective device (OCPD) feeding a lower

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK30SP 30A 600V TD Dual Elem Class RK Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK30SP 30A 600V Class RK Low Peak Dual Element, Time Delay Fuse 600 (lbs/each)

More information

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL 3804 South Street 75964-763, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 H100R3C 3P 100A 600V F-Frame MC Protector Eaton Corp Catalog Number H100R3C Manufacturer Eaton Corp Description Motor Circuit

More information

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS

DISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS Prepared by: SXZO DISCONNECT SWITCH REQUIREENTS FOR DISTRIBUTED GENERATION CUSTOERS 060559 Department: Electric Distribution Section: Design and Construction Approved by: D.Jantz (DWJ7) Date: 8/15/17 Rev.

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

Equipment Protection. Transformers 600V or Less

Equipment Protection. Transformers 600V or Less Equipment s or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers,

More information

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse LPSRK100SP 600V TD Dual Elem Class RK1 Low Peak Fuse Catalog Number Manufacturer Description Weight per unit Product Category LPSRK100SP 600V Class RK1 Low Peak Dual Element, Time Delay Fuse 0.4100 (lbs/each)

More information

************************************************************************************************************* PART 1 GENERAL 1.

************************************************************************************************************* PART 1 GENERAL 1. 16620 STANDBY EMERGENCY ELECTRICAL GENERATOR (CNG/LPG) ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number:

More information

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES SERIES E-RATED / MEDIUM VOLTAGE FUSES 5kV AND 15kV CLIP-LOCK MOUNTED FUSES Amp-trap E-rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as

More information

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225 January 1 Vol. 1, Ref. No. [0487] 2 Amperes - Product Selection Table -33. s,, and E Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Suitable for Reverse Feed Maximum Continuous Ampere

More information

SECTION MOTOR CONTROLLERS

SECTION MOTOR CONTROLLERS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 SPEC WRITER NOTE: Use this section only for NCA projects. Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph

More information

Ice Rink Renovation & New Clubhouse

Ice Rink Renovation & New Clubhouse SECTION 262913 - ENCLOSED CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

Now - Up To 400A Mains!

Now - Up To 400A Mains! Quik-Spec Family Specification has never been easier or faster for the distribution products you need to achieve selective coordination, and improve electrical system safety and performance Quik-Spec Coordination

More information

www. ElectricalPartManuals. com TRI-PAC circuit breakers current limiting protectors for. lighting, power and distribution circuits

www. ElectricalPartManuals. com TRI-PAC circuit breakers current limiting protectors for. lighting, power and distribution circuits desoriptioa The TR-PAC breaker is essentially an AB De-ion 19 circuit breaker incorporating a current-limiting device which enables it to be used on distribution systems where fault currents up to 1, symmetrical

More information

Power Break II Switchboard

Power Break II Switchboard Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 16410 Enclosed Switches and Circuit Breakers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

Switchboards Instant Service

Switchboards Instant Service January 1 Vol. 1, Ref. No. [0845] Switchboards Instant Service - Accessories Table -57. Meter Compartment Doors (Meter Sockets Not Included) Door Size Dimensions Drilling Inches mm H x 32 W 381.0 H x 8.8

More information

Design Standards NEMA

Design Standards NEMA Design Standards Although several organizations are involved in establishing standards for the design, construction, and application of motor control centers, the primary standards are established by UL,

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

SECTION LOW VOLTAGE SWITCHBOARDS - Spectra Bolt-On

SECTION LOW VOLTAGE SWITCHBOARDS - Spectra Bolt-On PART 1 GENERAL A. The requirements of the Contract, Division 1, and Division 16 apply to work in this Section. 1.01 SECTION INCLUDES A. Low Voltage, Front-Accessible and Front/Rear-Accessible switchboards

More information

Quik-Spec Electrical Gear

Quik-Spec Electrical Gear Section Contents Page Quik-Spec Coordination Panel Boards......... 266-267 Quik-Spec Power Module Switches and Panels.. 268-269 Quik-Spec DC Safety Switches.................. 270 Quik-Spec AC Safety Switches..................

More information

Lighting and Power Distribution Panelboards

Lighting and Power Distribution Panelboards EXPLOSIONPROOf Lighting and Power Distribution Panelboards The design offers sufficient gutter space on sides to allow through wiring and easy lug connection. All enclosures are furnished with hinges,

More information

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless

More information

Busway Construction. Bus Bars

Busway Construction. Bus Bars Busway Construction Bus Bars A better understanding of what busway is can be gained by examining its construction. A typical Siemens Sentron busway section has three or four formed aluminum or copper bars

More information

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL SECTION 23 04 10 ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information