Low Voltage Directive Report

Size: px
Start display at page:

Download "Low Voltage Directive Report"

Transcription

1 Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C F TEL: FAX: The test results of this report relate only to the tested sample identified in this report. This report shall not be reproduced, except in full, or with the written approval of Superior Product Consulting, Inc.

2

3

4 DECLARATION OF CONFORMITY According to the Low Voltage Directive 2006/95/EC Type of Product : NPort IA Series Device Service Model Designation : 1) NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate EIP3270I, MGate MB3270I-T, MGate EIP3270I-T. 2) NPort IA-5150-S-SC, NPort IA-5150-S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate EIP3170I, MGate MB3170I-T, MGate EIP3170I-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T. 3) NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGate EIP3170, MGate MB3170-T, MGate EIP3170-T, NPort IA-5250, NPort IA-5250-T, MGate MB3270, MGate EIP3270, MGate MB3270-T, MGate EIP3270-T. Manufacturer s Name : MOXA INC Manufacturer s Address : 4TH FL 135 LANE 235 PAO CHIAO RD SHING TIEN CITY TAIPEI, 231 TAIWAN Is herewith confirmed to comply with the requirements set out in the Council Directive 2006/95/EC for electrical equipment used within certain voltage limits. For the evaluation of the compliance with these Directive, the following standard was applied: IEC :2005, Second Edition; EN :2006+A11:2009, Second Edition Person responsible for making this declaration Name, Surname : Position/Title : (Place) (Date) (Company stamp and signature)

5 鼎安科技股份有限公司 Page 1 of 118 Report No.: SPCLVD COVER PAGE FOR TEST REPORT Product: Model/Type Reference: NPort IA Series Device Service 1) NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate EIP3270I, MGate MB3270I-T, MGate EIP3270I-T. 2) NPort IA-5150-S-SC, NPort IA-5150-S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate EIP3170I, MGate MB3170I-T, MGate EIP3170I-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, NPort IA- 5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I- M-SC-T. Rating(s): Standards: 3) NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGate EIP3170, MGate MB3170-T, MGate EIP3170-T, NPort IA-5250, NPort IA-5250-T, MGate MB3270, MGate EIP3270, MGate MB3270-T, MGate EIP3270-T. 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional) 3) Vdc, maximum 435 ma (Optional) IEC : 2005, 2nd. Edition; EN :2006+A11:2009 Applicant Name and Address: MOXA INC 4TH FL 135 LANE 235 PAO CHIAO RD SHING TIEN CITY TAIPEI 231 TAIWAN Factory Location(s): MOXA INC. 8TH FL 128 LANE 235 PAO CHIAO RD SHING TIEN TAIPEI HSIEN 231 TAIWAN. This Report includes the following parts, in addition to this cover page: 1. Specific Technical Criteria 2. Clause Verdicts 3. Critical Components 4. Test Results 5. Enclosures a. National Differences b. Photographs c. Diagrams d. Miscellaneous This is to certify that representative samples of the products covered by this Test Report have been investigated by Superior Product Consulting, Inc. in accordance with the above referenced Standards. The products have been found to comply with the requirements. This report shall not be reproduced, except in full, or with the written approval of Superior Product Consulting, Inc..

6 鼎安科技股份有限公司 Page 2 of 118 Report No.: SPCLVD Test Report By: Reviewed By: Eddie Shue Manager Allen Huang Assistant General Manager

7 鼎安科技股份有限公司 Page 3 of 118 Report No.: SPCLVD TEST REPORT IEC / EN , Second Edition Information technology equipment - Safety- Part 1: General Requirements Report Reference No...: SPCLVD Compiled by...: Eddie Shue Manager Reviewed by...: Allen Huang Assistant General Manager Date of issue...: Testing laboratory name...: Superior Product Consulting, Inc. Testing location...: 3F, No. 10, Alley 6, Lane 235, Pao Chiao Rd., Hsien Tien, Taipei, Taiwan Applicant's name... : Address... : MOXA INC 4TH FL 135 LANE 235 PAO CHIAO RD SHING TIEN CITY TAIPEI, 231 TAIWAN Test specification: Standards...: IEC :2005, Second Edition EN :2006, Second Edition Test procedure...: QE-19, UL/IEC/EN nd Non-standard test method...: NA Test item description...: NPort IA Series Device Service Trademark...: MOXA Model and/or type reference...: 1) NPort IA-5150-M-SC, NPort IA-5150-M-SC-T, MGate MB3170-M- SC, MGate MB3170-M-SC-T, NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate EIP3270I, MGate MB3270I-T, MGate EIP3270I-T. 2) NPort IA-5150-S-SC, NPort IA-5150-S-SC-T, MGate MB3170-S- SC, MGate MB3170-S-SC-T, NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate EIP3170I, MGate MB3170I-T, MGate EIP3170I-T, NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M- SC-T. 3) NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGate EIP3170, MGate MB3170-T, MGate EIP3170-T, NPort IA-5250, NPort IA T, MGate MB3270, MGate EIP3270, MGate MB3270-T, MGate EIP3270-T. Rating(s)...: 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional)

8 鼎安科技股份有限公司 Page 4 of 118 Report No.: SPCLVD ) Vdc, maximum 435 ma (Optional) Summary of Testing: Unless otherwise indicated, all tests were conducted at Superior Product Consulting, Inc. 3rd Fl, 10 Alley 6, Lane 235 Pao Chiao Rd, Hsin-Tien, Taipei, Taiwan. Tests performed (name of test and test clause) Testing location / Comments Input: Single-Phase (1.6.2) Loading - Wall and Ceiling Mounted Equipment (4.2.10) Lithium Battery Reverse Current Measurement (4.3.8) Heating (4.5.1, , ) Overload of Operator Accessible Connector (5.3.7) Summary of Compliance with National Differences: AT, AU, BE, CA, CH, CZ, DE, DK, ES, EU, FI, FR, GB, GR, HU, IE, IT, JP, KR, NL, NO, PL, PT, SE, SI, SK, US

9 鼎安科技股份有限公司 Page 5 of 118 Report No.: SPCLVD Copy of Marking Plate NPort IA-5150-M-SC 510 ma

10 鼎安科技股份有限公司 Page 6 of 118 Report No.: SPCLVD Particulars: test item vs. test requirements Equipment mobility... : movable Operating condition... : continuous Mains supply tolerance (%)... : No direct connection Tested for IT power systems... : No IT testing, phase-phase voltage (V)... : Class of equipment... : Class III (supplied by SELV) Mass of equipment (kg)... : 0.16 Protection against ingress of water... : IP X0 Possible test case verdicts: - test case does not apply to the test object... : N / A - test object does meet the requirement... : Pass - test object does not meet the requirement... : Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") Testing: Date(s) of receipt of test item...: Date(s) of Performance of tests...: to General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. Refer to the Cover Page For Test Report for a list of all Factory Locations.

11 鼎安科技股份有限公司 Page 7 of 118 Report No.: SPCLVD GENERAL PRODUCT INFORMATION: Report Summary All applicable tests according to the referenced standard(s) have been carried out. Product Description The unit was configured as follows: Consists of electronic components mounted on PWB, Fiber connector, Series connector (RS-232), RS422/485 connector or Ethernet (RJ45) connector, and housed with plastic enclosure. Model Differences All models are similar to NPort IA-5150 except for output connector type and model designation detailed as blew. Models NPort IA-5150-T, MGate MB3170 and, MGate MB3170-T, MGate EIP3170 and MGate EIP3170-T are identical to Model NPort IA-5150 except for model designation. Models NPort IA-5150I-T, MGate MB3170I and, MGate MB3170I-T, MGate EIP3170I and MGate EIP3170I- T are identical to Model NPort IA-5150I except for model designation. Models NPort IA-5250-T, MGate MB3270, and MGate MB 3270-T, MGate EIP3270, MGate EIP3270-T, NPort IA-5250I-T, MGate MB3270I, and MGate MB3270I-T, MGate EIP3270I and MGate EIP3270I-T are identical to Model NPort IA-5250 except for model designation. Models NPort IA-5150-S-SC-T, MGate MB3170-S-SC and MGate MB3170-S-SC-T are identical to Model NPort IA-5150-S-SC except for model designation. Models NPort IA-5150-M-SC-T, MGate MB3170-M-SC and MGate MB3170-M-SC-T are identical to Model NPort IA-5150-M-SC except for model designation. Models NPort IA-5150I-S-SC-T, MGate MB3170I-S-SC and MGate MB3170I-S-SC-T are identical to Model NPort IA-5150I-S-SC except for model designation. Models NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC and MGate MB3170I-M-SC-T are identical to Model IA-5150I-M-SC except for model designation. Additional Information The units are considered to be a Class III devices supplied by SELV. All applicable subclauses related to the AC mains connection, and AC Adapters, which were separately certified, are noted as "". The product was investigated to the following additional standards: EN :2006+A11:2009 (which includes all European national differences, including those specified in this test report). Licenses for critical components to be furnished by applicant upon request. For Instruction manual provided with the unit, reviewed only English language. Applicant to furnish Instructions in language suitable for countries noted in National Differences Enclosure of the report when submitting for National Certification. The above label is a draft of an artwork for marking plate pending approval by National Certification Bodies and it shall not be affixed to products prior to such an approval.

12 鼎安科技股份有限公司 Page 8 of 118 Report No.: SPCLVD The artwork provided is representative of all models in the Series. See Enclosure Miscellaneous for addition Australia national differences as listed in CB bulletin 110A, June 2006 are according to IEC :2001 First Edition. Technical Considerations The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 55 degree C. The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual

13 鼎安科技股份有限公司 Page 9 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict 1 GENERAL Pass 1.5 Components Pass General Pass Comply with IEC or relevant component standard Components, which were found to affect safety aspects, comply with the requirements of this standard or within the safety aspects of the relevant IEC component standards. See Table for details Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this Standard. Components not certified are used in accordance with their ratings and comply with IEC and the relevant components Standards. Components, for which no relevant IEC Standard exist, have been tested under the condition occurring in the equipment, using applicable parts of IEC Thermal controls Transformers Interconnecting cables Interconnecting cables comply with the relevant requirements of this standard Capacitors bridging insulation All secondary circuit Resistors bridging insulation Resistors bridging functional, basic or supplementary insulation Resistors bridging double or reinforced insulation between a.c. mains and other circuits Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable Accessible parts Components in equipment for IT power systems Surge suppressors General Protection of VDRs Bridging of functional insulation by a VDR Pass Pass Pass

14 鼎安科技股份有限公司 Page 10 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Bridging of basic insulation by a VDR Bridging of supplementary, double or reinforced insulation by a VDR 1.6 Power interface Pass AC power distribution systems Input current Steady state input current of the equipment does not exceed the rated current by more than 10% under Maximum Normal Load. See Table for details Voltage limit of hand-held equipment Not hand-held equipment Neutral conductor Pass 1.7 Marking and instructions Pass Power rating Pass Rated voltage(s) or voltage range(s) (V)...: VDC Symbol for nature of supply, for d.c. only...: IEC No provided on marking label. Rated frequency or rated frequency range (Hz)...: Rated current (ma or A)...: 1) Vdc, maximum 510 ma (Optional) 2) Vdc, maximum 555 ma (Optional) 3) Vdc, maximum 435 ma (Optional) Manufacturer's name or trademark or identification mark...: trademark "MOXA" Model identification or type reference...: See cover page for details. Symbol for Class II equipment only...: Other markings and symbols...: Additional symbols may be provided when submitted for National Approval Safety instructions and marking Quick Installation Guide in English. Other languages will be provided when submitted for National Approval General Disconnect devices Overcurrent protective device IT Power distribution systems Operator access with a tool Pass Pass Pass Pass Pass

15 鼎安科技股份有限公司 Page 11 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Ozone Short duty cycles Supply voltage adjustment...: Method and means of adjustment; reference to installation instructions...: Power outlets on the equipment...: Fuse identification (marking, special fusing characteristics, cross-reference)...: Wiring terminals Protective earthing and bonding terminals...: Terminal for a.c. mains supply conductors Terminals for d.c. mains supply conductors Controls and indicators Pass Identification, location and marking...: Colours...: Only functional indicators use color Symbols according to IEC : No switches provided Markings using figures...: Isolation of multiple power sources...: Thermostats and other regulating devices...: Durability All markings provided on UL Recognized Component labels suitable for surface they are applied upon and meet the durability test Removable parts Marking is not placed on removable parts Replaceable batteries...: Following statement provided on outer surface of battery pack or in user and service manual, or as described in individual descriptive sections: "Caution. Danger Of Explosion If Battery Is Incorrectly Replaced. Replace Only With The Same Or Equivalent Type Recommended By The Manufacturer. Dispose Of Used Batteries According To The Manufacturer's Instructions." Language(s)...: Equipment for restricted access locations...: Equipment not intended for installation in a restricted access location. Pass Pass Pass Pass

16 鼎安科技股份有限公司 Page 12 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict 2 PROTECTION FROM HAZARDS Pass 2.1 Protection from electric shock and energy hazards Pass Protection in operator access areas Pass Access to energized parts SELV levels are maintained after single fault condition. Test by inspection...: Operator can not contact with any parts with only basic insulation to ELV or hazardous voltage. Test with test finger (Figure 2A)...: Test with test pin (Figure 2B)...: Test with test probe (Figure 2C)...: Battery compartments No battery compartments provided Access to ELV wiring Working voltage (Vpeak or Vrms); minimum distance through insulation (mm)...: Access to hazardous voltage circuit wiring Energy hazards...: Manual controls Discharge of capacitors in equipment Measured voltage (V); time-constant (s)...: Energy hazards - d.c. mains supply a) Capacitor connected to the d.c. mains supply...: b) Internal battery connected to the mains supply.: Audio amplifiers...: Protection in service access areas Protection in restricted access locations Pass Pass SELV circuits Pass General requirements Supplied by SELV. Pass Voltages under normal conditions (V)...: All accessible voltages are less than 42.4 Vpk or 60 Vdc and are classified as SELV Voltages under fault conditions (V)...: Evaluated during separate certification of power supply Connection of SELV circuits to other circuits...: SELV circuits are only connected to other secondary circuits. Pass Pass 2.3 TNV circuits Limits No TNV circuits.

17 鼎安科技股份有限公司 Page 13 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Type of TNV circuits...: Separation from other circuits and from accessible parts General requirements Protection by basic insulation Protection by earthing Protection by other constructions...: Separation from hazardous voltages Insulation employed...: Connection of TNV circuits to other circuits Insulation employed...: Test for operating voltages generated externally 2.4 Limited current circuits General requirements Limit values Frequency (Hz)...: - Measured current (ma)...: - Measured voltage (V)...: - Measured circuit capacitance (nf or uf)...: Connection of limited current circuits to other circuits 2.5 Limited power sources a) Inherently limited output b) Impedance limited output c) Regulating network limited output under normal operating and single fault condition d) Overcurrent protective device limited output Max. output voltage (V), max. output current (A), max. apparent power (VA)...: Current rating of overcurrent protective device (A) : Provisions for earthing and bonding Protective earthing Class III equipment Functional earthing Protective earthing and protective bonding conductors General

18 鼎安科技股份有限公司 Page 14 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Size of protective earthing conductors Rated current (A), cross-sectional area (mm2), AWG...: Size of protective bonding conductors Rated current (A), cross-sectional area mm2), AWG...: Resistance of earthing conductors and their terminations; resistance (ohm), voltage drop (V), test current (A), duration (min)...: Colour of insulation...: Terminals General Protective earthing and bonding terminals Rated current (A), type, nominal thread diameter (mm)...: Separation of the protective earthing conductor from protective bonding conductors Integrity of protective earthing Interconnection of equipment Components in protective earthing conductors and protective bonding conductors Disconnection of protective earth Parts that can be removed by an operator Parts removed during servicing Corrosion resistance Screws for protective bonding Reliance on telecommunication network or cable distribution system Overcurrent and earth fault protection in primary circuits Basic requirements Not connect to primary circuit directly. Instructions when protection relies on building installation Faults not covered in Short-circuit backup protection Number and location of protective devices...: Protection by several devices Warning to service personnel...: 2.8 Safety interlocks

19 鼎安科技股份有限公司 Page 15 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict General principles There are no interlock provided Protection requirements Inadvertent reactivation Fail-safe operation Moving parts Overriding Switches and relays Contact gaps (mm)...: Overload test Endurance test Electric strength test Mechanical actuators 2.9 Electrical insulation Pass Properties of insulating materials Evaluated during separate certification of power supply Humidity conditioning Relative humidity (%), temperature ( C)...: Grade of insulation Separation from hazardous voltages FUNCTIONAL INSULATION. Pass Method(s) used...: Clearances, creepage distances and distances through insulation Pass General Pass Frequency...: Pollution degrees...: 2 Pass Reduced values for functional insulation See Sub clause for details Intervening unconnected conductive parts Insulation with varying dimensions Special separation requirements Insulation in circuits generating starting pulses Determination of working voltage General RMS working voltage Peak working voltage Clearances All critical clearance distances are covered in power supply evaluation. Pass Pass

20 鼎安科技股份有限公司 Page 16 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict General Unit is to be powered by an external AC adapter with Limited Power Source, only functional insulation required. See Sub-Clause for details Mains transient voltages a) AC mains supply...: b) Earthed d.c. mains supplies...: c) Unearthed d.c.. mains supplies...: d) Battery operation...: Clearances in primary circuits Evaluated as part of approved power adaptor Clearances in secondary circuits See Sub-Clause for details Clearances in circuits having starting pulses Transients from a.c. mains supply...: Transients from d.c. mains supply...: Transients from telecommunication networks and cable distribution systems...: Measurement of transient voltage levels a) Transients from a mains supply For an a.c. mains supply...: For a d.c. mains supply...: b) Transients from a telecommunication network Creepage distances All critical creepage distances are covered in power supply evaluation General Unit is to be powered by an external AC adapter with Limited Power Source, only functional insulation required Material group and comparative tracking index Pass CTI tests...: Material group IIIb; 100 <=CTI < Minimum creepage distances See Sub-Clause for details Solid insulation General Distances through insulation Insulating compound as solid insulation Semiconductor devices Cemented joints Thin sheet material - General Pass Pass Pass Pass -

21 鼎安科技股份有限公司 Page 17 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Separable thin sheet material Number of layers (pcs)...: Non-separable thin sheet material Thin sheet material - standard test procedure Electric strength test...: Thin sheet material - alternative test procedure Electric strength test...: Insulation in wound components Wire in wound components Working voltage...: a) Basic insulation not under stress...: b) Basic, supplementary, reinforced insulation...: c) Compliance with Annex U...: Two wires in contact inside wound component; angle between 45 and 90...: Wire with solvent-based enamel in wound components Electric strength test...: - Routine test Additional insulation in wound components Working voltage...: - Basic insulation not under stress...: - Supplementary, reinforced insulation...: Construction of printed boards Uncoated printed boards Coated printed boards Insulation between conductors on the same inner surface of a printed board Insulation between conductors on different layers of a printed board Distance through insulation Number of insulation layers (pcs)...: Component external terminations Tests on coated printed boards and coated components Sample preparation and preliminary inspection Thermal conditioning Electric strength test Abrasion resistance test Thermal cycling Test for Pollution Degree 1 environment and

22 鼎安科技股份有限公司 Page 18 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict insulating compound Tests for semiconductor devices and cemented joints Enclosed and sealed parts 3 WIRING, CONNECTIONS AND SUPPLY Pass 3.1 General Pass Current rating and overcurrent protection Protection against mechanical damage Securing of internal wiring Insulation of conductors Beads and ceramic insulators Screws for electrical contact pressure Insulating materials in electrical connections No contact pressure through insulating material Self-tapping and spaced thread screws Termination of conductors 10 N pull test Sleeving on wiring Pass 3.2 Connection to mains supply Means of connection Connection to an a.c. mains supply Connection to a d.c. mains supply Multiple supply connections Permanently connected equipment The equipment is not permanently connected. Number of conductors, diameter of cable and conduits (mm)...: Appliance inlets Power supply cords AC power supply cords Type...: - Rated current (A), cross-sectional area (mm2), AWG...: DC power supply cords Cord anchorages and strain relief Mass of equipment (kg), pull (N)...: - Longitudinal displacement (mm)...: Protection against mechanical damage - -

23 鼎安科技股份有限公司 Page 19 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Cord guards Diameter of minor dimension D (mm); test mass (g)...: Radius of curvature of cord (mm)...: Supply wiring space Wiring terminals for connection of external conductors Wiring terminals Connection of non-detachable power supply cords Screw terminals Conductor sizes to be connected Rated current (A), cord/cable type, cross-sectional area (mm2)...: Wiring terminal sizes Rated current (A), type and nominal thread diameter (mm)...: Wiring terminals design Grouping of wiring terminals Stranded wire Disconnection from the mains supply General requirement Disconnect devices Permanently connected equipment Parts which remain energized Switches in flexible cords Number of poles - single-phase and d.c. equipment Number of poles - three-phase equipment Switches as disconnect devices Plugs as disconnect devices Interconnected equipment Multiple power sources 3.5 Interconnection of equipment Pass General requirements Pass Types of interconnection circuits...: Interconnection circuits are SELV circuits ELV circuits as interconnection circuits Data ports for additional equipment Pass Pass

24 鼎安科技股份有限公司 Page 20 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict 4 PHYSICAL REQUIREMENTS Pass 4.1 Stability Pass Angle of 10 Test force (N)...: Based on construction, the test was deemed not necessary. Pass 4.2 Mechanical strength Pass General Steady force test, 10 N Steady force test, 30 N Steady force test, 250 N Impact test Fall test Swing test Drop test; height (mm)...: Not hand-held equipment Stress relief test Cathode ray tubes Picture tube separately certified...: High pressure lamps Wall or ceiling mounted equipment; force (N)...: Mounting means withstands minimum 50N. Pass 4.3 Design and construction Pass Edges and corners All edges and corners are judged to be sufficiently well rounded so as not to constitute a hazard Handles and manual controls; force (N)...: Adjustable controls Securing of parts Electrical and mechanical connections can be expected to withstand usual mechanical stress Connection by plugs and sockets Equipment does not have any interchangeable plugs/sockets Direct plug-in equipment Not direct plug-in equipment. Torque...: Compliance with the relevant mains plug standard: Heating elements in earthed equipment Batteries Battery is protected against Pass Pass

25 鼎安科技股份有限公司 Page 21 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict charging current by components Diode and Resistor rated 1.5Kohm. See Table for specific component identification. Abnormal reverse current = 0.1 ma < 3.0 ma. - Overcharging of a rechargeable battery - Unintentional charging of a non-rechargeable battery - Reverse charging of a rechargeable battery - Excessive discharging of any battery Oil and grease Dust, powders, liquids and gases Containers for liquids or gases Flammable liquids...: Quantity of liquid (l)...: Flash point ( C)...: Radiation Pass General LED indicators. Pass Ionizing radiation Measured radiation (pa/kg)...: - Measured high-voltage (kv)...: - Measured focus voltage (kv)...: - CRT markings...: Effect of ultraviolet (UV) radiation on materials Part, property, retention after test, flammability classification...: Human exposure to ultraviolet (UV) radiation...: Laser (including LEDs) This product contains only visible indicator LEDs (Class 1) operating in the range of nm wavelength. No IEC evaluation was deemed necessary. Additional review may be required at the discretion of the accepting NCB. Laser class...: (For indicator LEDs, see above statement.) Other types...: Pass Protection against hazardous moving parts General

26 鼎安科技股份有限公司 Page 22 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Protection in operator access areas...: Protection in restricted access locations...: Protection in service access areas 4.5 Thermal requirements Pass General Pass Temperature tests See Table 4.5 for details. Pass Normal load condition per Annex L...: Operated in the most unfavorable way of operation given in the operating instructions until steady conditions established Temperature limits for materials Pass Touch temperature limits Pass Resistance to abnormal heat...: Openings in enclosures Pass Top and side openings Pass Dimensions (mm)...: No openings Bottoms of fire enclosures Construction of the bottom, dimensions (mm)...: No openings Doors or covers in fire enclosures Openings in transportable equipment Not transportable equipment Constructional design measures Dimensions (mm)...: Evaluation measures for larger openings Use of metallized parts Adhesives for constructional purposes No barrier or screen secured with adhesive. Conditioning temperature ( C), time (weeks)...: Resistance to fire Pass Reducing the risk of ignition and spread of flame Method 1: Selection and application of components and materials which minimize the possibility of ignition and spread of flame. Method 1, selection and application of components wiring and materials Method 2, application of all of simulated fault condition tests Pass Pass

27 鼎安科技股份有限公司 Page 23 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Conditions for a fire enclosure With having the following components: - Components in secondary circuits supplied by LPS (limited power source) and mounted on materials of flammability class V-1. No fire enclosure is required Parts requiring a fire enclosure Parts not requiring a fire enclosure Circuit supplied by limited power source complying with Sub-clause 2.5 and with components mounted on materials of Class V-1 or better Materials Pass General Components and materials have adequate flammability classification. See Table Materials for fire enclosures Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures Decorative parts and parts outside of enclosure are made of minimum HB material. All internal materials are rated minimum V-2 or are mounted on a PWB rated minimum V Materials for air filter assemblies Materials used in high-voltage components Pass Pass Pass 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS Pass 5.1 Touch current and protective conductor current General Class III equipment (supplied by SELV) Configuration of equipment under test (EUT) Single connection to an a.c. mains supply Redundant multiple connections to an a.c. mains supply Simultaneous multiple connections to an a.c. mains supply Test circuit Application of measuring instrument Test procedure Test measurements Supply voltage (V)...: -

28 鼎安科技股份有限公司 Page 24 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Measured touch current (ma)...: - Max. allowed touch current (ma)...: - Measured protective conductor current (ma)...: - Max. allowed protective conductor current (ma)...: Equipment with touch current exceeding 3,5 ma General...: Simultaneous multiple connections to the supply Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network or to a cable distribution system Supply voltage (V)...: - Measured touch current (ma)...: - Max. allowed touch current (ma)...: Summation of touch currents from telecommunication networks a) EUT with earthed telecommunication ports...: b) EUT whose telecommunication ports have no reference to protective earth 5.2 Electric strength General Test procedure 5.3 Abnormal operating and fault conditions Pass Protection against overload and abnormal operation Motors Transformers Functional insulation...: Functional insulation complies with the requirements (c) Electromechanical components Audio amplifiers in ITE...: Simulation of faults (see appended table 5.3) Pass Unattended equipment Compliance criteria for abnormal operating and fault conditions No fire, emission of molten metal or deformation was noted during the tests During the tests Pass Pass Pass

29 鼎安科技股份有限公司 Page 25 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict After the tests Pass 6 CONNECTION TO TELECOMMUNICATION NETWORKS 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment Protection from hazardous voltages Separation of the telecommunication network from earth Requirements Supply voltage (V)...: - Current in the test circuit (ma)...: Exclusions...: 6.2 Protection of equipment users from overvoltages on telecommunication networks Separation requirements Electric strength test procedure Impulse test Steady-state test Compliance criteria 6.3 Protection of the telecommunication wiring system from overheating Max. output current (A)...: - Current limiting method...: - 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS 7.1 General 7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment 7.3 Protection of equipment users from overvoltages on the cable distribution system 7.4 Insulation between primary circuits and cable distribution systems General Voltage surge test Impulse test A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see )

30 鼎安科技股份有限公司 Page 26 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict A.1.1 Samples...: - Wall thickness (mm)...: - A.1.2 Conditioning of samples; temperature ( C)...: A.1.3 Mounting of samples...: A.1.4 Test flame (see IEC ) Flame A, B, C or D...: A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)...: - Sample 2 burning time (s)...: - Sample 3 burning time (s)...: - A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material...: - Wall thickness (mm)...: - A.2.2 Conditioning of samples; temperature ( C)...: A.2.3 Mounting of samples...: A.2.4 Test flame (see IEC ) Flame A, B or C...: - A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)...: - Sample 2 burning time (s)...: - Sample 3 burning time (s)...: - A.2.7 Alternative test acc. to IEC , cl. 5 and 9 Sample 1 burning time (s)...: - Sample 2 burning time (s)...: - Sample 3 burning time (s)...: - A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see and 5.3.2) B.1 General requirements Position...: - Manufacturer...: - Type...: -

31 鼎安科技股份有限公司 Page 27 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Rated values...: - B.2 Test conditions B.3 Maximum temperatures B.4 Running overload test B.5 Locked-rotor overload test Test duration (days)...: - Electric strength test: test voltage (V)...: - B.6 Running overload test for d.c. motors in secondary circuits B.6.1 General B.6.2 Test procedure B.6.3 Alternative test procedure B.6.4 Electric strength test; test voltage (V)...: B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 General B.7.2 Test procedure B.7.3 Alternative test procedure B.7.4 Electric strength test; test voltage (V)...: B.8 Test for motors with capacitors B.9 Test for three-phase motors B.10 Test for series motors Operating voltage (V)...: - C ANNEX C, TRANSFORMERS (see and 5.3.3) Position...: - Manufacturer...: - Type...: - Rated values...: - Method of protection...: - C.1 Overload test C.2 Insulation Protection from displacement of windings...: D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) D.1 Measuring instrument D.2 Alternative measuring instrument

32 鼎安科技股份有限公司 Page 28 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict E ANNEX E, TEMPERATURE RISE OF A WINDING (see ) F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G) Pass G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES G.1 Clearances G.1.1 General G.1.2 Summary of the procedure for determining minimum clearances G.2 Determination of mains transient voltage (V) G.2.1 AC mains supply...: G.2.2 Earthed d.c. mains supply...: G.2.3 Unearthed d.c. mains supply...: G.2.4 Battery operation...: G.3 Determination of telecommunication network transient voltage (V) :...: G.4 Determination of required withstand voltage (V) G.4.1 Mains transients and internal repetitive peaks...: G.4.2 Transients from telecommunication networks...: G.4.3 Combination of transients G.4.4 Transients from cable distribution systems G.5 Measurement of transient voltages (V) G.6 Determination of minimum clearances...: H ANNEX H, IONIZING RADIATION (see ) J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see ) Metal(s) used...: - K ANNEX K, THERMAL CONTROLS (see and 5.3.8) K.1 Making and breaking capacity K.2 Thermostat reliability; operating voltage (V)...: K.3 Thermostat endurance test; operating voltage (V).: K.4 Temperature limiter endurance; operating voltage (V)...: K.5 Thermal cut-out reliability

33 鼎安科技股份有限公司 Page 29 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict K.6 Stability of operation L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see and 4.5.2) L.1 Typewriters L.2 Adding machines and cash registers L.3 Erasers L.4 Pencil sharpeners L.5 Duplicators and copy machines L.6 Motor-operated files L.7 Other business equipment Operated in the most unfavorable way of operation given in the operating instructions until steady conditions established. Pass Pass M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) M.1 Introduction M.2 Method A M.3 Method B M.3.1 Ringing signal M Frequency (Hz)...: - M Voltage (V)...: - M Cadence; time (s), voltage (V)...: - M Single fault current (ma)...: - M.3.2 Tripping device and monitoring voltage...: M Conditions for use of a tripping device or a monitoring voltage M Tripping device M Monitoring voltage (V)...: N ANNEX N, IMPULSE TEST GENERATORS (see , , , , 7.3.2, and Clause G.5) N.1 ITU-T impulse test generators N.2 IEC impulse test generator P ANNEX P, NORMATIVE REFERENCES Pass

34 鼎安科技股份有限公司 Page 30 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Q ANNEX Q, Voltage dependent resistors (VDRs) (see ) a) Preferred climatic categories...: b) Maximum continuous voltage...: c) Pulse current...: R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL PROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2)...: - U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see )...: - V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) V.1 Introduction V.2 TN power distribution systems W ANNEX W, SUMMATION OF TOUCH CURRENTS W.1 Touch current from electronic circuits W.1.1 Floating circuits W.1.2 Earthed circuits W.2 Interconnection of several equipments W.2.1 Isolation W.2.2 Common return, isolated from earth

35 鼎安科技股份有限公司 Page 31 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict W.2.3 Common return, connected to protective earth X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) X.1 Determination of maximum input current X.2 Overload test procedure Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see ) Y.1 Test apparatus...: Y.2 Mounting of test samples...: Y.3 Carbon-arc light-exposure apparatus...: Y.4 Xenon-arc light-exposure apparatus...: Z ANNEX Z, OVERVOLTAGE CATEGORIES (see and Clause G.2) Pass AA ANNEX AA, MANDREL TEST (see )

36 鼎安科技股份有限公司 Page 32 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict TABLE: list of critical components Pass Object/part No. Manufacturer/ trademark type/model technical data Standard Mark(s) of conformity 1 ) 01 Enclosure Various Various V-2 min., 120 degree C, 1.5 mm thick min. Two pieces construction, secured together by screws. Overall 120 by 90 mm. 02 Printed Wiring Various Various Min V-1, 105 degree Board 03 RTC Battery (BT1) (for all models) Panasonic Corporation, Panasonic Corporation Of North America BR1225 C Maximum reverse charging current 3 ma. Mounted on PWB, referred to Enclosure Ids 3-02, 3-04, 3-06, 3-08, 3-10, 3-12 and Label Various Various Min. 40 degree C, if max. surface temperature not specified 05 Terminal Block 06A Power Adapter (optional) 06B DC Power Supply-alternate (optional) 07. Fiber Optical Transceiver Output connector for models: NPort Dinkle Enterprise Co., Ltd. 5EHD*d (*d:followed by R or V,may be follow by C and/or M, followed by 2-7 alphanumeri c digits) 300 V, 15 A, 105 degree C, AWG 12 to 28 Solid, stranded, FW2, screw torque 4.5 lb. In. must be shown near screw Various Various Provided with a connector for field wiring terminal. O/P: Vdc, 510 ma min. mark with "LPS" or "Limited Power Source" or "Class 2" on unit Various Various Provided with a connector for field wiring terminal. O/P: Vdc, 510 ma min., meet the "LPS" requirements. SANway Optoelectronic s technology Corporation SX1X2X3X4 X5- X6X7X8X9X 10 Two provided, for optical fiber transceiver Single mode. Laser Class V, 90mA One series (RS-232) port, one RS-422/485 port, two RJ45 ports UL 94 UL, -- UL 796 UL, -- UL 1642 UL, -- UL 969 UL, -- UL 1059 UL, -- UL/EN/IEC , UL 1310 UL/EN/IEC , UL UL, TUV, CB UL, TUV, CB

37 鼎安科技股份有限公司 Page 33 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict IA-5150, NPort IA-5150-T, MGate MB3170, MGate MB3170- T, NPort IA- 5150I, NPort IA T, MGate MB3170I, MGate MB3170I-T Output connector for models: NPort IA-5250, NPort IA-5250-T, MGate MB3270, MGate MB T, NPort IA- 5250I, NPort IA- 5250I-T, MGate MB3270I, MGate MB 3270I-T Output connector for models: NPort IA-5150-S-SC, NPort IA-5150-S- SC-T, MGate MB3170-S-SC, MGate MB3170- S-SC-T, NPort IA-5150I-S-SC, NPort IA-5150I- S-SC-T, MGate MB3170I-S-SC, MGate MB3170I- S-SC-T Output connector for models: NPort IA-5150-M-SC, NPort IA M-SC-T, MGate MB3170-M-SC, MGate MB3170- M-SC-T, NPort IA-5150I-M-SC, NPort IA-5150I- M-SC-T, MGate MB3170I-M-SC, MGate MB3170I- M-SC-T 09 Connectors and Receptacles (secondary ELV/SELV circuits) Two series (RS-232) ports, two RJ45 ports One series (RS-232) port, one RS-422/485 port, one Fiber Optical Transceiver (single mode or multi mode) One series (RS-232) port, one RS-422/485 port, one Fiber Optical Transceiver (single mode or multi mode) -- Metal/Plastic Copper alloy pins housed in bodies of plastic rated V-2 min UL94 UL, --

38 鼎安科技股份有限公司 Page 34 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict 10 Interconnecting Cable Lithium battery (BT1) (for Models NPort IA- 5150, NPort IA T, MGate MB3170,MGate MB3170-T, MGate EIP3170, MGate EIP3170- T, NPort IA S-SC, NPort IA-5150-S- SC-T,MGate MB3170-S- SC,MGate MB3170-S-SC-T, NPort IA M-SC, NPort IA M-SC- T,MGate MB3170-M- SC,MGate MB3170-M-SC- T) Lithium battery (BT1) (for Models NPort IA- 5150I, NPort IA- 5150I-T,MGate MB3170I,MGate MB3170I-T, MGate EIP3170I, MGate EIP3170I- T NPort IA- 5150I-S- SC,NPort IA- 5150I-S-SC- T,MGate MB3170I-S- SC,MGate MB3170I-S-SC- T, NPort IA- 5150I-M- SC,NPort IA- 5150I-M-SC- T,MGate MB3170I-M- SC,MGate MB3170I-M-SC- T) Various Various Optional, rated minimum 30 V, 60 degree C, Max m long, jacketed, marked "VW-1" or "FT-1" Panasonic Corporation, Panasonic Corporation Of North America Panasonic Corporation, Panasonic Corporation Of North America VL1220 VL1220 Maximum abnormal charging current of 300 ma. Reverse current protection by series circuit of diode D21 and resistor R142, rated 1.5 k ohm. Mounted on PWB, referred to Enclosure Ids 3-15 and Maximum abnormal Charging Current 300 ma. Reverse current protection by series circuit of diode D21 and resistor R143, rated 1.5 k ohm. Mounted on PWB, referred to Enclosure Ids 3-17, 3-18 and UL 758 UL, -- UL 1642 UL, -- UL 1642 UL, --

39 鼎安科技股份有限公司 Page 35 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Lithium battery (BT1) (for Models NPort IA- 5250, NPort IA T, MGate MB3270,MGate MB3270-T, MGate EIP3270 and MGate EIP3270-T, NPort IA- 5250I,NPort IA- 5250I-T,MGate MB3270I,MGate MB3270I-T, MGate EIP3270I and MGate EIP3270I-T) Panasonic Corporation, Panasonic Corporation Of North America VL1220 Maximum abnormal Charging Current 300 ma. Reverse current protection by series circuit of diode D6 and resistor R124, rated 1.5 k ohm. Mounted on PWB, referred to Enclosure Ids 3-20 and UL 1642 UL, --

40 鼎安科技股份有限公司 Page 36 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: IEC Clause Requirement + Test Result - Remark Verdict TABLE: electrical data (in normal conditions) Pass fuse # I rated (A) U (V) P (W) I (ma) I fuse (ma) condition/status Model: Nport IA Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150I Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150-S-SC Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150-M-SC Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150I-S-SC Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Model: Nport IA-5150I-M-SC Vdc Maximum normal load, supply by DC power

41 鼎安科技股份有限公司 Page 37 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: IEC Clause Requirement + Test Result - Remark Verdict Vdc Maximum normal load, supply by DC power Vdc Maximum normal load, supply by adapter Test on Model MGate MB dc Maximum Normal Load dc Maximum Normal Load Test on Model MGate MB3170I dc Maximum Normal Load dc Maximum Normal Load Test on Model MGate MB dc Maximum Normal Load dc Maximum Normal Load Test on Model MGate MB3270I dc Maximum Normal Load dc Maximum Normal Load Test on Model NPort IA-5150-S- SC dc Maximum Normal Load dc Maximum Normal Load Test on Model NPort IA-5150I-S- SC dc Maximum Normal Load dc Maximum Normal Load Test on Model NPort IA-5150I-M- SC dc Maximum Normal Load dc Maximum Normal Load supplementary information: "Maximum normal load" was defined as follows: Connected with network and computer and operated continuously. Adapter rating 12Vdc for reference and TABLE: clearance and creepage distance measurements Pass clearance cl and creepage distance dcr at/of: Up (V) U r.m.s. (V) required cl (mm) cl (mm) required dcr (mm) supplementary information: dcr (mm) All circuits are SELV and only functional insulation required.

42 鼎安科技股份有限公司 Page 38 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: IEC Clause Requirement + Test Result - Remark Verdict TABLE: distance through insulation measurements distance through insulation di at/of: Up (V) test voltage (V) required di (mm) di (mm) supplementary information: 4.5 TABLE: temperature rise measurements Pass test voltage (V)... See below See below See below See below -- t1 ( C) t2 ( C) maximum temperature T of part/at: T ( C) allowed Tmax ( C) Test sample Model: Nport IA-5150I-M-SC Normal Condition Condi Conditio Conditio Conditio tion 1 (Origi nal) n 1 (Shift to 55) n 2 (Original ) n 2 (Shift to 55) Ambient D23 body C43 body L4 coil PWB near U PWB near U PWB near U C34 body RTC battery body U16 body Enclosure inside near U Enclosure outside near U Normal Condition Condi tion 3 (Origi nal) Conditio n 3 (Shift to 55) Conditio n 4 (Original ) Conditio n 4 (Shift to 55) Ambient D23 body C43 body L4 coil PWB near U PWB near U PWB near U

43 鼎安科技股份有限公司 Page 39 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: IEC Clause Requirement + Test Result - Remark Verdict C34 body RTC battery body U16 body Enclosure inside near U Enclosure outside near U temperature T of winding: R 1 (Ω) R 2 ( Ω) T ( C) allowed Tmax ( C) supplementary information: Conditions: Test Condition 1: 48Vdc (Horizontal), Duration 4hrs. 12mins. Test Condition 2: 48Vdc (Vertical), Duration 3hrs. 27mins. Test Condition 3: 12Vdc (Vertical), Duration 2hrs. 15mins. Test Condition 4: 12Vdc (Horizontal), Duration 4hrs. 25mins. insulation class Comments: The temperatures were measured by thermal couple method under worst case normal mode defined in and described in 1.6.2, at voltages described in With a specified max. ambient temperature of 55 degree C Allowed T max ( C) defined as below: Tmax (Enclosure inside near U4)=120 C Tmax (PWB)=105 C Tmax (RTC battery)=100 C Tmax (IC, Cap., Diode)=105 C Tmax (Wiring)=105 C External surfaces of equipment which may be touch Tmax(Plastic)=95 C TABLE: ball pressure test of thermoplastics allowed impression diameter (mm)... : part test temperature ( C) impression diameter (mm) supplementary information: 4.7 TABLE: resistance to fire Pass part manufacturer of material type of material thickness(mm) flammability class Printed Wiring Board Various Various -- V-1 min.

44 鼎安科技股份有限公司 Page 40 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: IEC Clause Requirement + Test Result - Remark Verdict Internal Plastic Parts Plastic Enclosure supplementary information: -- Various Various -- V-2 min. Various Various 1.5 mm min. V-2 min. 5.2 TABLE: electric strength tests, impulse tests and voltage surge tests test voltage applied between: test voltage (V) a.c./d.c. breakdown Yes / No supplementary information: 5.3 TABLE: fault condition tests Pass component No. ambient temperature ( C)... : -- model/type of power supply... : -- manufacturer of power supply... : -- rated markings of power supply... : -- fault test voltage (V) test time fuse No. fuse current (A) Lithium Battery Reverse Current Measurement Test U15 (pins 4-8) result Short 48Vdc Measured abnormal reverse current = 0.1 ma. Maximum abnormal charging current = 3 ma Overload of Operator Accessible Connector Test Model: Nport IA-5150 RS232 connector pins 1~9 RS422/485 connector pins 1~5 Ethernet 1 (RJ-45) connector pins 1~8 Overload 48Vdc C Overload 48Vdc C Overload 48Vdc C

45 鼎安科技股份有限公司 Page 41 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: IEC Clause Requirement + Test Result - Remark Verdict Ethernet 2 Overload 48Vdc C (RJ-45) connector pins 1~ Model: Nport IA-5150I RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~5 Ethernet 1 Overload 48Vdc C (RJ-45) connector pins 1~8 Ethernet 2 Overload 48Vdc C (RJ-45) connector pins 1~ Model: Nport IA-5250 RS232 (P1) Overload 48Vdc C connector pins 1~9 RS232 (P2) Overload 48Vdc C connector pins 1~9 Ethernet 1 Overload 48Vdc C (RJ-45) connector pins 1~8 Ethernet 2 Overload 48Vdc C (RJ-45) connector pins 1~ Model: Nport IA-5150-S-SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~ Model: Nport IA-5150-M-SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 connector pins 1~5 Overload 48Vdc C

46 鼎安科技股份有限公司 Page 42 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: IEC Clause Requirement + Test Result - Remark Verdict Model: Nport IA-5150I-S-SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~ Model: Nport IA-5150I-M- SC RS232 Overload 48Vdc C connector pins 1~9 RS422/485 Overload 48Vdc C connector pins 1~5 D5 Short circuit 48 Vdc 7 hrs Unit shut down, cell body = 38 degree C, enclosure = 27 degree C, ambient = 23 degree C, no hazards. D6 (2-3) Short circuit 48 Vdc 7 hrs Unit operation normally, cell body = 63 degree C, enclosure = 35 degree C, ambient = 23 degree C, no hazards. D20 (4-8) Short circuit 48 Vdc 7 hrs Unit operation normally, cell body = 66 degree C, enclosure = 37 degree C, ambient = 25 degree C, no hazards. supplementary information: Results Key: C - Circuit measures 0 Volts

47 鼎安科技股份有限公司 Page 43 of 118 Report No.: SPCLVD SUPERIOR PRODUCT CONSULTING, INC Issue Date: Enclosure National Differences Australia* Austria** Belgium** Czech Republic** Denmark Finland France** Germany Greece** Group Hungary** Ireland Italy** Japan* Korea Netherlands** Norway Poland** Portugal** Slovakia** Slovenia** Spain Sweden Switzerland USA / Canada United Kingdom * No National Differences Declared ** Only Group Differences

48 鼎安科技股份有限公司 Page 44 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Denmark - Differences to IEC :2005, Second Edition Certain types of Class I appliances (see sub-clause ) may be provided with plug not establishing earthing continuity when inserted into Danish socket-outlets Supply cords of Class I equipment, which is delivered without a plug, must be provided with a visible tag with the following text: "Vigtigt! Lederen med gron/gul isolation ma kun tilsluttes en klemme market (IEC 417, No. 5019) eller (IEC 417, No. 5017)." If essential for the safety of the equipment, the tag must in addition be provided with a diagram, which shows the connection of the other conductors, or be provided with the following text: "For tilslutning af de ovrige ledere, se medfolgende installationsvejledning" Socket-outlets for providing power to other equipment shall be in accordance with the Heavy Current Regulations, Section D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For stationary equipment, the socket0outlet shall be in accordance with Standard Sheet DK 1-1b or DK 1-5a With the exception of CLASS II EQUIPMENT provided with a socket outlet in accordance with the Heavy Current Regulations, Section D1, Standard Sheet DK 1-4a, CLASS II EQUIPMENT shall not be fitted with socket-outlets for providing power to other equipment Supply cord of single-phase equipment having a rated current not exceeding 13 A shall be provided with a plug according to the Heavy Current Regulations, Section D1. Class I equipment provided with socket-outlets with earth contact or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If poly-phase equipment and single-phase equipment having a rated current exceeding 13 A is provided with a supply cord with a plug, this plug

49 鼎安科技股份有限公司 Page 45 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict shall be in accordance with the Heavy Current Regulations, Section D1 or EN TOUCH CURRENT measurement results exceeding 3,5 ma r.m.s. are permitted only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE EQUIPMENT TYPE B. Finland - Differences to IEC :2005, Second Edition Resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in The third dashed sentence is applicable only to equipment as defined by this annex, Class I Pluggable Equipment Type A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text shall be: "Laite on liitettava suojamaadoitus-koskettimilla varustettuun pistorasiaan" Requirements according to this annex, and apply Requirements according to this annex, and apply Touch current measurement results exceeding 3,5 ma r.m.s are permitted only for the following equipment: - Stationary pluggable equipment Type A that: (1) is intended to be used in a Restricted Access Location where equipotential bonding has been applied, for example, in a telecommunication centre; and (2) has provision for a permanently connected protective earthing conductor; and (3) is provided with instructions for the installation of that conductor by a service person; - Stationary pluggable equipment Type B - Stationary permanently connected equipment Add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of

50 鼎安科技股份有限公司 Page 46 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with EN :1994, subclass Y2. A capacitor classified Y3 according to EN :1994, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN :2006, ; - the additional testing shall be performed on all the test specimens as described in EN ; - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN The exclusions are applicable for permanently connected equipment and pluggable equipment type B and equipment intended to be used in a restricted access location where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected protective earthing conductor and is provided with instructions for the installation of that conductor by a service person. 7.2 Requirements according to this annex, and apply with the term telecommunication network in being replaced by the term cable distribution system.

51 鼎安科技股份有限公司 Page 47 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Germany - Differences to IEC :2005, Second Edition If for the assurance of safety and health certain rules during use, amending or maintenance of a technical labour equipment or readymade consumer product are to be followed, a manual in German language has to be delivered when placing the product on the market. Of this requirement, rules for use even only by SERVICE PERSONS are not exempted. Safety instructions in English. Other languages will be provided when submitted for National Approval. Group - Differences to IEC :2005, Second Edition 1.3.Z1 Exposure to excessive sound pressure - The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose, either in normal operating conditions or under fault conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones. NOTE Z1 A new method of measurement is described in EN , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 1: General method for one package equipment, and in EN , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 2: Guidelines to associate sets with headphones coming from different manufacturers Add the following NOTE Z1: The use of certain substances in electrical and electronic equipment is restricted within the EU: see Directive 2002/95/EC Add the following NOTE Z1: In addition, the instructions shall include, as far as applicable, a warning that excessive sound pressure from earphones and headphones can cause hearing loss Replace the subclause as follows: Basic requirements To protect against excessive current, short-circuits and earth faults in primary circuits, protective devices shall be included either as integral parts of the equipment or as parts of the building installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements See Enclosure Miscellaneous for manufacturer's letter of assureance. Pass

52 鼎安科技股份有限公司 Page 48 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault protection may be provided by protective devices in the building installation; c) it is permitted for pluggable equipment type B or permanently connected equipment, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for pluggable equipment type A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet Void Delete the NOTE and conduit sizes in parentheses in Table 3A Replace: "60245 IEC 53" by "H05 RR-F" "60227 IEC 52" by "H03 VV-F or H03 VVH2-F" "60227 IEC 53" by "H05 VV-F or H05 VVH2-F" In table 3B, replace the first four lines by the following: Up to and including a) Over 6 up to and including b) 1.0 Over 10 up to and including c) 1.5 In the conditions applicable to table 3B, delete the words "in some countries" in condition a). In Note 1, applicable Table 3B, to delete the second sentence In table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following: "Over 10 up to and including to to by 4" Delete the fifth line: conductor sizes for 13 to 16A Add the following NOTE Z1: Attention is drawn to 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards taking into account this Recommendation which demonstrate compliance with the applicable EU Directive are indicated in the OJEC.

53 鼎安科技股份有限公司 Page 49 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict H Replace the last paragraph of this annex by: At any point 10 cm from the surface of the operator access area, the dose rate shall not exceed 1 gsv/h (0,1 mr/h) (see note). Account is taken of the background level. Replace the notes as follows: NOTE - These values appear in Directive 96/29/Euratom. Delete Note 2. Ireland - Differences to IEC :2005, Second Edition Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525: National Standards Authority of Ireland (section 28) (13 A Plugs and Conversion Adaptors for Domestic Use) Regulations DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such devices shall comply with Statutory Instrument 526: National Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, Korea - Differences to IEC :2005, Second Edition Plugs for the connection of the apparatus to the mains supply shall comply withe the Korean requirement (KSC 8305) 8 EMC - The apparatus shall comply with the relevant CISPR standards To be provided when submitted for National Approval. Norway - Differences to IEC :2005, Second Edition Resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in Due to the IT power system used (see annex V, figure V.7), capacitors are required to be rated for the applicable phase-to-phase voltage ( 230 V) The third dashed sentence is applicable only to equipment as defined by this annex, Class I Pluggable Equipment Type A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if

54 鼎安科技股份有限公司 Page 50 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text shall be: "Apparatet ma tilkoples jordet stikkontakt" Requirements according to this annex, , and apply Requirements according to this annex, and apply Requirements according to this annex, , and apply Requirements according to this annex, and apply Touch current measurement results exceeding 3,5 ma r.m.s are permitted only for the following equipment: - Stationary pluggable equipment Type A that: (1) is intended to be used in a Restricted Access Location where equipotential bonding has been applied, for example, in a telecommunication centre; and (2) has provision for a permanently connected protective earthing conductor; and (3) is provided with instructions for the installation of that conductor by a service person; - Stationary pluggable equipment Type B - Stationary permanently connected equipment Add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by

55 鼎安科技股份有限公司 Page 51 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with EN :1994, subclass Y2. A capacitor classified Y3 according to EN :1994, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN :2006, ; - the additional testing shall be performed on all the test specimens as described in EN ; - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN The exclusions are applicable for permanently connected equipment and pluggable equipment type B and equipment intended to be used in a restricted access location where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected protective earthing conductor and is provided with instructions for the installation of that conductor by a service person. 7.2 Requirements according to this annex, and apply with the term telecommunication network in being replaced by the term cable distribution system. 7.3 There are many buildings where the screen of the coaxial cable is not normally connected to the earth in the building installation 7.3 Refer to EN :2005 for installation conditions Spain - Differences to IEC :2005, Second Edition Supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315:1994. Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UNE-EN 50075:1993.

56 鼎安科技股份有限公司 Page 52 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UNE 20315:1994. If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UNE-EN Sweden - Differences to IEC :2005, Second Edition (Ordinance (1990:944)) Add NOTE: Switches containing mercury such as thermostats, relays and level controllers are not allowed Resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in The third dashed sentence is applicable only to equipment as defined by this annex, Class I Pluggable Equipment Type A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text shall be: "Apparaten skall anslutas till jordat uttag" Requirements according to this annex, and apply Requirements according to this annex, and apply Touch current measurement results exceeding 3,5 ma r.m.s are permitted only for the following equipment: - Stationary pluggable equipment Type A that: (1) is intended to be used in a Restricted Access Location where equipotential bonding has been applied, for example, in a telecommunication centre; and (2) has provision for a permanently connected protective earthing conductor; and (3) is provided with instructions for the installation of that conductor by a service person; - Stationary pluggable equipment Type B - Stationary permanently connected equipment "Add the following text between the first and second paragraph of the compliance clause:

57 鼎安科技股份有限公司 Page 53 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with EN :1994, subclass Y2. A capacitor classified Y3 according to EN :1994, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN :2006, ; - the additional testing shall be performed on all the test specimens as described in EN ; - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN " The exclusions are applicable for permanently connected equipment and pluggable equipment type B and equipment intended to be used in a restricted access location where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected protective earthing conductor and is provided with instructions for the installation of that conductor by a service person.

58 鼎安科技股份有限公司 Page 54 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict 7.2 Requirements according to this annex, and apply with the term telecommunication network in being replaced by the term cable distribution system. 7.3 There are many buildings where the screen of the coaxial cable is not normally connected to the earth in the building installation Switzerland - Differences to IEC :2005, Second Edition Add NOTE: Switches containing mercury such as thermostats, relays and level controllers are not allowed Annex 2.15 of SR applies for batteries Supply cords of equipment having a rated current not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC and one of the following dimension sheets: SEV , Plug type 15, 3P+N+PE 250/400 V,10 A SEV , Plug type 11, L+N 250 V,10 A SEV , Plug type 12, L+N+PE 250 V,10 A In general, EN applies for plugs for currents exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998: SEV , Plug type 25, 3P+N+PE 230/400 V,16 A SEV , Plug type 21, L+N 250 V,16 A SEV , Plug type 23, L+N+PE 250 V,16 A Requirements according to this annex, apply USA / Canada - Differences to IEC :2005, Second Edition 1.1 Equipment able to be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1, and when applicable, the National Electrical Safety Code, IEEE C Equipment able to be installed in accordance with Pass Pass

59 鼎安科技股份有限公司 Page 55 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded Special requirements apply to equipment intended for use outdoors For Pluggable Equipment Type A, the protection in the installation is assumed to be 20 A All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of CSA and UL component standards in Annex P All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like For other than limited power and TNV circuits, the type of output circuit identified for output connector External cable assemblies that exceed 3.05 m in length to be types specified in the NEC and CEC Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope Telephone line and extension cords and the like comply with UL 1863 and CSA C22.2 No Equipment intended for connection to a d.c. power (mains) distribution system is subject to special circuit classification requirements (e.g., TNV-2) Optional provided. Optional provided Earthing of d.c. powered equipment provided. 1.7 Lamp replacement information indicated on lampholder in operator access area Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor Equipment voltage rating not higher than rating of the plug except under special conditions. Pass Pass Pass Pass

60 鼎安科技股份有限公司 Page 56 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Special fuse replacement marking for operator accessible fuses Identification of terminal connection of the equipment earthing conductor Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used Marking located adjacent to terminals and visible during wiring Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M b b For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 ma peak or 30 ma d.c. under normal conditions. Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M In the event of a single fault, the limits of apply to SELV circuits and accessible conductive parts Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and routine testing. 2.5 Overcurrent protection device required for Class 2 and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with devices of higher ratings if operator replaceable. 2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth For Pluggable Equipment Type A, if a) b) or c) are not applicable, the current rating of the circuit is taken as 20 A

61 鼎安科技股份有限公司 Page 57 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit Protective bonding conductors and their terminals of non-standard constructions (e.g. PWB traces) evaluated to limited short-circuit test of CSA C22.2 No Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US and Canada Data for selection of special external branch circuit overcurrent devices marked on the equipment Standard supply outlets protected by overcurrent device in accordance with the NEC, and CEC, Part Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring Additional requirements for overcurrent protection apply to equipment provided with panelboards Non-motor-operated equipment requiring special overcurrent protective device marked with device rating Multi-layer winding wire subject to UL component wire requirements in addition to and Annex U Permissible combinations of internal wiring/external cable sizes for overcurrent and short circuit protection All interconnecting cables protected against overcurrent and short circuit. 3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC and CEC, Part Permitted use for flexible cords and plugs Flexible cords provided with attachment plug rated 125% of equipment current rating Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord).

62 鼎安科技股份有限公司 Page 58 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC, Part Permanently connected equipment may have terminals or leads not smaller than No. 18 AWG (0.82 mm2) and not less than 150 mm in length for connection of field installed wiring If supply wires exceed 60 C, marking indicates use of 75 C or 90 C wiring for supply connection as appropriate Equipment compatible with suitable trade sizes of conduits and cables Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation Conductors in power supply cords sized according to NEC and CEC, Part I Power supply cords and cord sets incorporate flexible cords suitable for the particular application Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source Adequate wire bending space and volume of field wiring compartment required to properly make the

63 鼎安科技股份有限公司 Page 59 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict field connections Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse. 3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm2) or smaller conductor if provided with upturned lugs, cupped washer or equivalent retention Terminals accept wire sizes (gauge) used in the U.S. and Canada Terminals accept current-carrying conductors rated 125% of the equipment current rating Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V Vertically mounted disconnect devices oriented so up position of handle is "on" For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more Compartment housing high-pressure lamp marked

64 鼎安科技股份有限公司 Page 60 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict to indicate risk of explosion For equipment intended for mounting on racks and provided with slide/rails allowing the equipment to slide away from the rack for installation, service and maintenance, additional construction, performance and marking requirements are applicable to determine the adequacy of the slide/rails Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit In addition to the IEC requirements, Direct Plug-in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30(Table NAE.6) Equipment using replenishable liquids marked to indicate type of liquid to be used Equipment that produces x-radiation and does not comply with under all conditions of servicing marked to indicate the presence of radiation where readily visible Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040 and REDR C1370). 4.7 Automated information storage equipment intended to contain more than 0.76 m3 of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system Equipment for use in environmental air space other than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL Equipment for installation in space used for environmental air as described in Sec (c) of the NEC provided with instructions indicating suitability for installation in such locations Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m2 or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications Wire marked "VW-1" or "FT-1" considered equivalent. No internal wire provided.

65 鼎安科技股份有限公司 Page 61 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections Touch current due to ringing voltage for equipment containing telecommunication network leads Overloading of SELV connectors and printed wiring board receptacles accessible to the operator Tests interrupted by opening of a component repeated two additional times Test interrupted by opening of wire or trace subject to certain conditions. 6 Specialized instructions provided for telephones that may be connected to a telecommunications network. 6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network. 6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection. 6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable. 6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C). 6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions. 7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC. H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act, REDR C1370. M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations. M.4 Special requirements for message waiting and similar telecommunications signals. NAC Equipment intended for use with a generic secondary protector marked with suitable (see appended table 5.3) Pass

66 鼎安科技股份有限公司 Page 62 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict NAC instructions. Equipment intended for use with a specific primary or secondary protector marked with suitable instructions. NAD Acoustic pressure from an ear piece less than 136 dba for short duration disturbances, and less than 125 dba for handsets, 118 dba for headsets, and 121 dba for insert earphones, for long duration disturbances. NAD Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements. NAF Household/Home Office Document Shredders NAF.1.7 Markings and instructions alert the user to key safety considerations related to use of shredders, including not intended to be used by children, avoid touching document feed opening, avoid clothes and hair entanglement, and avoid aerosol products. NAF Safety interlock cannot be inadvertently activated by the articulated accessibility probe (figure NAF.1). NAF.3.4 NAF.4.4 Provided with an isolating switch complying with 3.4.2, including 3 mm contact gap, with appropriate markings associated with the switch. Hazardous moving parts are not accessible, as determined using the articulated accessibility probe (figure NAF.1) and the accessibility probe/wedge (figures NAF.2/NAF.3). United Kingdom - Differences to IEC :2005, Second Edition The current rating of the circuit shall be taken as 13 A, not 16 A To protect against excessive currents and shortcircuits in the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 shall be conducted, using an external protective device rated 30 A or 32 A. If these tests fail, suitable protective devices shall be included as integral parts of the DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a

67 鼎安科技股份有限公司 Page 63 of 118 Report No.: SPCLVD IEC : 2005, Second Edition, EN :2006 Clause Requirement + Test Result - Remark Verdict "standard plug" in accordance with Statutory Instrument 1786: The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations. NOTE: "Standard plug" is defined in SI 1786: 1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug A power supply cord with conductor of 1.25 mm2 is allowed for equipment with a rated current over 10A and up to and including 13A The range of conductor sizes of flexible cords to be accepted by terminals for equipment with a rated current of over 10 A up to and including 13 A is 1.25 mm2 to 1.5 mm2 nominal cross-sectional area The torque test is performed using a socket outlet complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, and 12.17, except that the test of is performed at not less than 125 C. Where the metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the requirements of clauses 22.2 and 23 also apply.

68 鼎安科技股份有限公司 Page 64 of 118 Report No.: SPCLVD Enclosure Photographs Supplement Id Description 3-01 Models NPort IA-5150(-T) overall view 3-02 Models NPort IA-5150(-T) internal view 3-03 Models NPort IA-5150I(-T) overall view 3-04 Models NPort IA-5150I(-T) internal view 3-05 Models NPort IA-5150I-M-SC(-T) overall view 3-06 Models NPort IA-5150I-M-SC(-T) internal view 3-07 Models NPort IA-5150I-S-SC(-T) overall view 3-08 Models NPort IA-5150I-S-SC(-T) internal view 3-09 Models NPort IA-5150-M-SC(-T) overall view 3-10 Models NPort IA-5150-M-SC(-T) internal view 3-11 Models NPort IA-5150-S-SC(-T) overall view 3-12 Models NPort IA-5150-S-SC(-T) internal view 3-13 Models NPort IA-5250(-T) overall view 3-14 Models NPort IA-5250(-T) internal view 3-15 Amendment 1 - Models NPort IA-5150, NPort IA-5150-T, MGate MB3170, MGATE MB3170-T, internal view 3-16 Amendment 1 - Models NPort IA-5150-S-SC, NPort IA-5150-S-SC-T, MGate MB3170-S-SC, MGate MB3170-S-SC-T, NPort IA-5150-M-SC, NPort IA M-SC-T, MGate MB3170-M-SC, MGate MB3170-M-SC-T, internal view 3-17 Amendment 1 - Models NPort IA-5150I, NPort IA-5150I-T, MGate MB3170I, MGate MB3170I-T, internal view 3-18 Amendment 1 - Models NPort IA-5150I-S-SC, NPort IA-5150I-S-SC-T,MGate MB3170I-S-SC, MGate MB3170I-S-SC-T, internal view 3-19 Amendment 1 - Models NPort IA-5150I-M-SC, NPort IA-5150I-M-SC-T, MGate MB3170I-M-SC, MGate MB3170I-M-SC-T, internal view 3-20 Amendment 1 - Models NPort IA-5250, NPort IA-5250-T, MGate MB3270,MGate MB3270-T internal view 3-21 Amendment 1 - NPort IA-5250I, NPort IA-5250I-T, MGate MB3270I, MGate MB3270I-T internal view

69 鼎安科技股份有限公司 Page 65 of 118 Report No.: SPCLVD Photographs ID 3-01

70 鼎安科技股份有限公司 Page 66 of 118 Report No.: SPCLVD Photographs ID 3-02

71 鼎安科技股份有限公司 Page 67 of 118 Report No.: SPCLVD Photographs ID 3-03

72 鼎安科技股份有限公司 Page 68 of 118 Report No.: SPCLVD Photographs ID 3-04

73 鼎安科技股份有限公司 Page 69 of 118 Report No.: SPCLVD Photographs ID 3-05

74 鼎安科技股份有限公司 Page 70 of 118 Report No.: SPCLVD Photographs ID 3-06

75 鼎安科技股份有限公司 Page 71 of 118 Report No.: SPCLVD Photographs ID 3-07

76 鼎安科技股份有限公司 Page 72 of 118 Report No.: SPCLVD Photographs ID 3-08

77 鼎安科技股份有限公司 Page 73 of 118 Report No.: SPCLVD Photographs ID 3-09

78 鼎安科技股份有限公司 Page 74 of 118 Report No.: SPCLVD Photographs ID 3-10

79 鼎安科技股份有限公司 Page 75 of 118 Report No.: SPCLVD Photographs ID 3-11

80 鼎安科技股份有限公司 Page 76 of 118 Report No.: SPCLVD Photographs ID 3-12

81 鼎安科技股份有限公司 Page 77 of 118 Report No.: SPCLVD Photographs ID 3-13

82 鼎安科技股份有限公司 Page 78 of 118 Report No.: SPCLVD Photographs ID 3-14

83 鼎安科技股份有限公司 Page 79 of 118 Report No.: SPCLVD Photographs ID 3-15

84 鼎安科技股份有限公司 Page 80 of 118 Report No.: SPCLVD Photographs ID 3-16

85 鼎安科技股份有限公司 Page 81 of 118 Report No.: SPCLVD Photographs ID 3-17

86 鼎安科技股份有限公司 Page 82 of 118 Report No.: SPCLVD Photographs ID 3-18

87 鼎安科技股份有限公司 Page 83 of 118 Report No.: SPCLVD Photographs ID 3-19

88 鼎安科技股份有限公司 Page 84 of 118 Report No.: SPCLVD Photographs ID 3-20

89 鼎安科技股份有限公司 Page 85 of 118 Report No.: SPCLVD Photographs ID 3-21

90 鼎安科技股份有限公司 Page 86 of 118 Report No.: SPCLVD Enclosure Manuals Supplement Id Description 6-01 Fiber DOC

91 鼎安科技股份有限公司 Page 87 of 118 Report No.: SPCLVD Manuals ID 6-01

92 鼎安科技股份有限公司 Page 88 of 118 Report No.: SPCLVD Enclosure Miscellaneous Supplement Id Description 7-01 Mounting means 7-02 Addition Australia National Difference 7-03 Addition national differences as listed in CB bulletin 110A, June 2006 are according to IEC First Edition Letter of assurance

93 鼎安科技股份有限公司 Page 89 of 118 Report No.: SPCLVD Miscellaneous ID 7-01

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2006-05-11 Page 1 of 2 Report Reference # E212360-A19-UL-1 Amendment 2 2009-07-03 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference:

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 55 Report No.:L611332L009 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009.

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009. ELECTRICAL TESTING 839.01 Hermon Laboratories Ltd. Tel.+972 4 628 8001 Fax.+972 4 628 8277 SAFETY TEST REPORT ACCORDING TO: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, IEC 60950-1:2005 (Second Edition)

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2011-01-12 Page 1 of 1 Report Reference # ASL10120310 COVER PAGE FOR TEST REPORT Test Item Description: Notebook PC Model/Type Reference: MS-16Y1 Rating(s): 19Vdc, 3.42A or 19Vdc, 4.74A Standards:

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2008-11-11 Page 1 of 2 Report Reference # E186249-A82-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power

More information

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences:

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences: age 3 of 106 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. re-production samples without serial

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements Page 1 of 49 Report Reference No....: 81790 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2009 TEST REPORT :2006 Information technology equipment Safety Part 1: General

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: GLOBAL ADVANTAGE INTERNATIONAL TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 46 TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 160414015SZN-002 Date of issue... : May 09, 2016 Total number of pages... : 77 pages Applicant

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-07-30 Page 1 of 6 Report Reference # E313912-A35-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 248792 Date of issue... : 2013-11-25

More information

A Test Lab Techno Corp.

A Test Lab Techno Corp. Report No. 1607CF12 age 1 of 52 TEST REORT AS/NZS60950.1:2011+A1:2013 Safety of Information Technology Equipment including Electrical business equipment Report Number.... : 1607CF12 Date of issue... :

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1712057S.50A Date of issue... : 2017-04-13 Total number

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....:

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements age 1 of 49 Report Reference No....: 80983 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2008 TEST REORT :2006 Information technology equipment Safety art 1: General

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard Doc: ET 31(6126) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard UNINTERRUPTIBLE POWER SYSTEMS (UPS)

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of GUAGDOG EAST OWER CO., LTD. Uninterruptible ower Supply Model(s): EA99300,EA99250,EA99200 repared For : GUAGDOG EAST OWER CO., LTD. o.6 orthern Industry

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): COVER PAGE FOR TEST REPORT Power Supplies for Information Technology Equipment Including Electrical Business

More information

LOW VOLTAGE DIRECTIVE TEST REPORT IEC / EN , First Edition Information technology equipment Safety Part 1: General requirements

LOW VOLTAGE DIRECTIVE TEST REPORT IEC / EN , First Edition Information technology equipment Safety Part 1: General requirements page 1 of 39 Report No.: L7D1808L658 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1 / EN 60950-1, First Edition Information technology equipment Safety Part 1: General requirements Report Reference No....

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number.... : TEST REORT Information technology equipment Safety art 1: General requirements Date of issue... : 7 March, 2017 Total number of pages...

More information

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Dycon D1532SM EN50131/PD6662 Grade 3, 12V 2A Power Supply Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD Tel: +44 (0)1443 471 900 Unit A Cwm Cynon Business Park Mountain

More information

National Standard. of the People s Republic of China

National Standard. of the People s Republic of China Translated English of Chinese Standard: GB4793.1-2007 www.chinesestandard.net Sales@ChineseStandard.net ICS 19.080; 71.040.10 L 09 National Standard GB of the People s Republic of China GB 4793.1-2007

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2003-09-25 Page 1 of 1 Report Reference # E203413-A17-CB-1 Test Item Description: Model/Type Reference: COVER PAGE FOR TEST REPORT Home Plug Device MS-6821 Rating(s): 100-240 Vac, 47-63 Hz,

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 72 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-05-26 Page 1 of 2 Report Reference # E310405-A9-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Power Supplies for

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No.... : Complied by (+ signature)... : 1205S019S

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS

More information

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77

TECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77 TECHNICAL REORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION SYSTEM NERA F77 ACCORDING TO EN 60950 (2000) REORT NO. 2002-3032 REVISION NO. 01 DET NORSKE VERITAS DET NORSKE VERITAS TECHNICAL

More information

Summary of testing: Testing location: Tests performed (name of test and test clause): Summary of compliance with National Differences:

Summary of testing: Testing location: Tests performed (name of test and test clause): Summary of compliance with National Differences: age 3 of 71 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. Testing location: All tests as described

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A

Page 2 of 41 Report No.: CTL WS. Input: Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A Ratings...: age 2 of 41 Report o.: CTL1607012503-WS Adapter: Input: 100-240Vac, 50/60Hz, 2A Output: 12V 5A Tablet Oscilloscope: 12V 5A age 3 of 41 Report o.: CTL1607012503-WS Summary of testing: Testing

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...

More information

Comments on sub clause of IEEE draft 802.3bt/D2.4 Presenter: Arkadiy Peker Co-author : Yair Darshan May 15, 2017

Comments on sub clause of IEEE draft 802.3bt/D2.4 Presenter: Arkadiy Peker Co-author : Yair Darshan May 15, 2017 Power Matters. TM Comments on sub clause 145.4.1 of IEEE draft 802.3bt/D2.4 Presenter: Arkadiy Peker Co-author : Yair Darshan May 15, 2017 1 Comments #121,122 Comment In the text Accessible external conductors

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

Technical Data. Dimensions

Technical Data. Dimensions Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush

More information

Copy of marking plate. Page 2 of 50 Report No. TRS

Copy of marking plate. Page 2 of 50 Report No. TRS Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date

More information

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

University of Houston Master Construction Specifications Insert Project Name

University of Houston Master Construction Specifications Insert Project Name SECTION 26 13 13 MEDIUM VOLTAGE SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

List of Attachments (including a total number of pages in each attachment):

List of Attachments (including a total number of pages in each attachment): www.lcs-cert.com age 2 of 25 Report No. LCS170508052AS List of Attachments (including a total number of pages in each attachment): Attachment 1: hoto documentation (3 pages). Summary of testing: Tests

More information

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter

Silvertel. 1. Features. 2. Description. IEEE802.3at compliant. Maximum 30 Watt Output Power. High efficiency DC/DC converter Silvertel V.0 May 2009. Features Pb IEEE802.3at compliant Maximum 30 Watt Output Power High efficiency DC/DC converter Wide adjustable output voltage range 500Vdc isolation (input to output) Input voltage

More information