Test Report. E4S-Box V1.0
|
|
- Archibald Wheeler
- 5 years ago
- Views:
Transcription
1 Test Report No. 05 / a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.
2 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 Customer: Electrical safety requirements Equipment under test: E4S-Box V1.0, SN: 8 Date of receipt: March 16, 2005 Date of test: March 16, 2005 Stollmann Entwicklungs- + Vertriebs GmbH Mendelssohnstraße 15 D Hamburg Test site: EMV Services GmbH & Co. KG Harburger Schlossstr D Hamburg Test personnel: Tel. Fax Dipl.-Ing. H. Meisel 040/ / meisel@emv-services.de Applied standards: EN (2001): Safety of information technology equipment The test results only apply to the Equipment under test.
3 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 Equipment under test and operating conditions Nominal voltage: 12 V DC (SELV) Description: The ES4 Box consists of 4 identical ISDN BRI S0 interfaces (TNV1), 1 Ethernet 100BaseT interface, 1 RS232 control port for service and a 12V DC power supply. The EUT was adapted to a mains adaptor as follows: ( tested by EMV-Services) Touch Electronic Co., Ltd. Model: SA06L1113-V input: V AC output: 12 V DC, 15 W LPS (limited power source) Tested by TÜV Rheinland, Certificate No. TA
4 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 s applicable Principles of safety 0 No Test General 1 Scope 1.1 No Test Definitions 1.2 No Test General requirements 1.3 No Test General conditions for tests 1.4 No Test Components 1.5 Not tested Power interface 1.6 X Power supply tested Marking and instructions 1.7 Power Marking No type plate on EUT Safety instructions X Short duty cycles X Marking for voltage / freqency settings X Marking at power outlets X Marking at fuseholders X Terminals X DC-phone jack Switches and controls X Isolation of multiple power sources X
5 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 Instructions for installation to IT power systems Indication at thermostats and regulating devices applicable Not tested X Language Operating instructions tested Durability X Removable parts X Replaceable batteries X Operator access with a tool X Equipment for restricted access locations X
6 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 applicable Protection from hazards 2 Protection from electric shock and energy hazards Protection against operator contact Protection in service access areas Protection in restricted access locations 2.1 X X X X SELV circuits 2.2 Power supply tested General requirements X Voltage under normal operating conditions Voltage after single fault conditions Connection of SELV circuits to other circuits X X Power supply: SELV method X TNV circuits 2.3 X Limited current circuits 2.4 X Limited power sources 2.5 X Provisions for earthing and bonding Overcurrent and earth fault protection in primary circuits 2.6 Power supply tested 2.7 Power supply tested Basic requirements 2.7.1
7 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 applicable Not used Short circuit backup protection Number and location of protective devices Protection by several devices Warning to service personal Safety interlocks 2.8 X Electrical insulation 2.9 Insulation parameters X Humidity treatment Not tested Categories of insulation X Clearances, creepage distances and distances through insulation 2.10 General X Nominal voltage X Clearances X Creepage distances X Solid insulation X Distances on coated printed boards X Enclosed and sealed parts X Spacings filled by insulating compound X
8 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 Component external terminations applicable X Insulation with varying dimensions Wiring, connections and supply Not tested 3 General 3.1 X Current rating and overcurrent protection Wireways Fixing of internal wiring Insulating of the conductors Fixing of beads and similar ceramic insulators Required electrical contact pressure Non-metallic materials in electrical connections Self-tapping screws Fixed conductors Insulating tubes Connection to a.c. / d.c. primary power 3.2 X Type of connection X
9 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 Design of product with more than one supply connection Provision of permanent connection applicable X X Connectors X Type and cross-sectional area of power supply cord X Cord anchorage X Protection of power supply cord X Cord guard X Supply wiring space X Wiring terminals for connection of external conductors 3.3 X Terminals Special non-detachable cord Screws and nuts Nominal thread diameters Size of terminals Condition of connectors Terminal location Test with 8 mm stranded wire Disconnection from the a.c. mains suply 3.4 X General reqirements 3.4.1
10 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 applicable Type of disconnect device Disconnect device in permanently connected equipment Parts of disconnect device which remain energized Switches in flexible cords Disconnection of both poles simultaneously for single-phase equipment Disconnection of all phase conductors of supply in threephase equipment Marking of switch acting as disconnect device Installation instructions if plug on power supply cord acts as disconnect device Interconnected equipment Multiple power sources Interconnection of equipment 3.5 General requirement X Type of interconnection circuits X SELV + TNV1 ELV circuits as interconnection circuits X
11 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 applicable Physical requirements 4 Stability 4.1 X Mechanical strength 4.2 Not tested Design and construction 4.3 Edges and corners X Knobs, grips, handles levers X Adjusting device X Protection of loosening parts X Interchangeable plugs and sockets Torque test for direct plug-in equipment Protection of heating elements in Class I equipment X X X Batteries X Resistance to oil and grease X Prevention of dangerous concentration of dust, powder, liquid and gas Protection against excessive pressure X X Flammable liquids X Radiation X Protection against hazardous moving parts 4.4 X
12 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 applicable Thermal requirements 4.5 Maximal temeratures X Maximal allowed temeratures X Openings in enclosures 4.6 Not tested Resistance to fire 4.7 Not tested Electrical requirements and simulated abnormal conditions Touchable current and earth leakage current General Tests below Equipment under test No test Test set-up No test Measuring equipment No test Test cycle No test Measurements X 0,21 ma Leakage current over 3.5 ma X Leakage current to TK networks X Σ < 0,25 ma Electric strength 5.2 X General Test procedure Abnormal operating and fault conditions 5.3 General LPS power supply
13 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 applicable Motors X Transformers X Compliance of operational insulation X Electromechanical components X Test in any expected condition an foreseeable misuse X Unattended use of equipment X Compliance X Connection to telecommunication networks Protection of telecommunication network service personal and users of other equipment connected to the network, from hazards in the equipment Protection of equipment users from overvoltages on telecommunication networks Protection of the telecommunication wiring system from overheating X ISDN PE: 1 kv AC 6.2 X 6.3 X
14 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 Connection to cable distribution network Protection cable distribution network service personal and users of other equipment connected to the network, from hazards in the equipment Protection of equipment users from overvoltages on cable distribution networks Insulation between primary power circuits and cable distribution networks applicable 7 X
15 Electrical safety requirements No. 05/ a EMV-05/ a Apr. 08, / 15 : No remarks Dr. E. Sauer Lab manager p.p. Dipl.-Ing. H. Meisel EMV Services GmbH & Co. KG Ein Unternehmen der TÜV Nord Gruppe Harburger Schloßstraße Hamburg End of the Test Report
Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas
AS 62040.1.1 2003 IEC 62040-1-1:2002 IEC 62040-1-1:2002/Corr.1:2002 Reconfirmed 2013 AS 62040.1.1 Australian Standard Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS
More informationApplicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address
Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):
More information< > Page 2 of 84
age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes
More informationIEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,
More informationTEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L
TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power
More informationTECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS
TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF
More informationBUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard
Doc: ET 31(6126) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard UNINTERRUPTIBLE POWER SYSTEMS (UPS)
More information1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems
Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems An additional function allows measuring residual currents in earthed power supplies (TN/TT systems) too.
More informationElectric Vehicle Conductive AC Charging System
AUTOMOTIVE INDUSTRY STANDARD Electric Vehicle Conductive AC Charging System PRINTED BY THE AUTOMOTIVE RESEARCH ASSOCIATION OF INDIA P.B. NO. 832, PUNE 411 004 ON BEHALF OF AUTOMOTIVE INDUSTRY STANDARDS
More informationTECHNICAL REPORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION REPORT NO REVISION NO. 01 DET NORSKE VERITAS SYSTEM NERA F77
TECHNICAL REORT NERA SATCOM AS TESTING OF SATELLITE MARITIME COMMUNICATION SYSTEM NERA F77 ACCORDING TO EN 60950 (2000) REORT NO. 2002-3032 REVISION NO. 01 DET NORSKE VERITAS DET NORSKE VERITAS TECHNICAL
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...
More informationLVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.
LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.
More informationElectric Vehicle Charging Safety Guidelines Part 2: Selection and Installation
86 Customhouse Quay PO Box 165, Wellington 6140 New Zealand Date of publication: 1 November 2016 Issued by: Mark Wogan, Manager Energy Safety WorkSafe New Zealand Electric Vehicle Charging Safety Guidelines
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2006-05-11 Page 1 of 2 Report Reference # E212360-A19-UL-1 Amendment 2 2009-07-03 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference:
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :
More informationL7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD
age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23
More informationLow Voltage Directive Report
Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test
More informationNational Standard. of the People s Republic of China
Translated English of Chinese Standard: GB4793.1-2007 www.chinesestandard.net Sales@ChineseStandard.net ICS 19.080; 71.040.10 L 09 National Standard GB of the People s Republic of China GB 4793.1-2007
More informationElectric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT
Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation
More informationpage 2 of 82 IEC 60950
page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,
More informationInformation technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements
More informationSERIES 54 Inductive Proximity Sensor
SENSOR FEATURES > 2-wire DC sensor with minimum off-state current > ATEX-approval for zone 2 and zone 22 > High temp, UV, salt water resistant > Rugged metal base > IP66/67/69K > High impact protection
More informationTEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7
TEST REORT NO.: A001T140610025001-2 Date: Jul 29, 2014 age 1 of 7 Applicant: EASY WAY(HONG KONG) CO.,LTD Address: Flat D, 13F Sing Kong Building 233 Lockhard Wanchai Hong Kong Report on the submitted sample
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationSECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS
SECTION 26 28 16 ENCLOSED SWITCHES AND PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following individually mounted, enclosed switches and circuit breakers rated 600V AC and less: 1. Fusible switches.
More informationSolenoid coil for control in potentially explosive areas Type BZ
Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationWIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST
WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST Use & Identification of Grounded and Grounding Conductors YES NO N/A Grounded conductors are identifiable and distinguishable from all other conductors.
More informationIET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS
IET Wiring Regulations (BS 7671:2008+A3:2015) - SECTION 717 MOBILE OR TRANSPORTABLE UNITS 717.1 Scope The particular requirements of this section apply to a.c. and d.c. installations for mobile or transportable
More informationTest Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY
Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:
More informationEPS/ELA-Series User Manual EPS/ELA 250W
EPS/ELA-Series User Manual EPS/ELA 250W EPS Stromversorgung GmbH Tel: +49 (0)821 570451 0 Index 3 Page: 1 Table of contents: Page 1. Features of ELA-Series... 3 1.1 Basic Functions... 3 1.2 Options...
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment
More informationOperating instruction and technical description
Operating instruction and technical description EV Simulator for charging devices with charging plug / charging coupler / charging cable type 1 and type 2 as service case Photo: EV simulator/tester with
More informationTEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements
More informationPHOENIX CONTACT
Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers
More informationElectric Vehicle Conductive DC Charging System
FINALIZED DRAFT AUTOMOTIVE INDUSTRY STANDARD Electric Vehicle Conductive DC Charging System Status chart of the standard to be used by the purchaser for updating the record AIS-138 (Part 2)/DF Sr. No.
More informationDISCONNECT SWITCH REQUIREMENTS FOR DISTRIBUTED GENERATION CUSTOMERS
Prepared by: SXZO DISCONNECT SWITCH REQUIREENTS FOR DISTRIBUTED GENERATION CUSTOERS 060559 Department: Electric Distribution Section: Design and Construction Approved by: D.Jantz (DWJ7) Date: 8/15/17 Rev.
More informationKey elements of the AS3000 Wiring standards and some of the recent changes.
Key elements of the AS3000 Wiring standards and some of the recent changes. Dean of Engineering Steve Mackay Worked for 30 years in Industrial Automation 30 years experience in mining, oil and gas, electrical
More informationPhotovoltaic Solar Plan Review
PAIGE B. VAUGHAN, CBO Director of Building and Safety Phone (310) 605-5509 Fax Line (310) 605-5598 E-mail:lbutler@comptoncity.org Building & Safety Department Photovoltaic Solar Plan Review Plan Check
More information013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS
013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification
More informationSUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More informationAS/NZS AS/NZS
TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05
More informationInstallation Couplers intended for permanent connection in fixed installation
age 1 of 14 Report o.47462 / rev.1 Test Report issued under the responsibility of: TEST REORT IEC 61535 Installation Couplers intended for permanent connection in fixed installation Report Reference o....
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201510) E-15 Uninterruptible Power Systems (UPS) Issued date:20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),
More information2016 Photovoltaic Solar System Plan Review List
Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE
More informationThis is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.
More informationMAGNETIC MOTOR STARTERS
Chapter 6 MAGNETIC MOTOR STARTERS 1 The basic use for the magnetic contactor is for switching power in resistance heating elements, lighting, magnetic brakes, or heavy industrial solenoids. Contactors
More informationecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity
Data Sheet 20.27 Page / ecotrans Lf 0/02 Microprocessor Transmitter / Switching Device for Conductivity Type 2027 Housing for DIN rail mounting (5 x 7.5 mm to EN 0 75 A.) Brief description The JUMO ecotrans
More informationTEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:
More informationDRAFT AUTOMOTIVE INDUSTRY STANDARD. Electric vehicle conductive DC charging system ARAI
DRAFT AUTOMOTIVE INDUSTRY STANDARD Electric vehicle conductive DC charging system ARAI Date of hosting on website: 22 nd September 2016 Last date of comments: 6 th October 2016 Page 1 of 142 CHECK LIST
More informationCOVER PAGE FOR TEST REPORT
Issue Date: 2008-11-11 Page 1 of 2 Report Reference # E186249-A82-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power
More informationPretest Module 29 High Voltage Unit 1
Pretest Module 29 High Voltage Unit 1 1. Is a person qualified to work on high-voltage installations when this module is completed? 2. What is the code definition of high-voltage? 3. What is the IEEE definition
More informationThis standard covers the requirements of lighting chains. This standard covers only the safety requirements.
FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the
More informationELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009.
ELECTRICAL TESTING 839.01 Hermon Laboratories Ltd. Tel.+972 4 628 8001 Fax.+972 4 628 8277 SAFETY TEST REPORT ACCORDING TO: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, IEC 60950-1:2005 (Second Edition)
More informationMAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS
MAKING MODERN LIVING POSSIBLE UniLynx Indoor Installation Manual ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS Contents Contents 1. Introduction 2 Introduction 2 Installation Sequence 2 Important
More informationUniversal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus
Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :
More information2.7. IT system floor-standing distribution cabinet Series -IPS-F
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 07-0 Fax: 0640 07-25 IT system floor-standing distribution cabinet Series -IPS-F for supplying power to medical locations
More informationLuminaire for road and street lighting. Approved by / Authorized Signatory:
Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test
More informationUnified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven
More informationDC/DC CONVERTER Safety Standards
DC/DC CONVERTER Safety Standards Safety Standards UL1950 & EN0950 1- General For the majority of DC/DC converter applications in the telecommunications and datacommunications equipment, the applicable
More informationTEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements
TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30
More information3000ZR PRECISION VOLTAGE REFERENCE 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS
3000ZR PRECISION VOLTAGE REFERENCE 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS 3000ZR Series Precision Voltage Standard Operation Manual Version 3.00 Aug 2013 All product names are trademarks
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),
More informationTesting Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.
11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797
More informationINTERPLANT STANDARD - STEEL INDUSTRY
INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION FOR MAGNETIC OVER- CURRENT RELAYS FOR ac AND dc MOTORS PROTECTION UP TO 650 V (FIRST REVISION) CORRESPONDING INDIAN STANDARD DOES NOT EXIST IPSS:1-04-008-11
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,
More informationPUBLIC NOTICE. 1. Central Electricity Authority (Technical Standards for Connectivity of Distributed Generation Resources) Regulations, 2013.
GOVERNMENT OF INDIA CENTRAL ELECTRICITY AUTHORITY (MINISTRY OF POWER) 6 th Floor (N), Sewa Bhawan, R. K. Puram, New Delhi-110066 Tel. Fax: 26103246, e.mail: celegal-cea@gov.in, website: www.cea.nic.in
More informationTEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools
age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.10.225.01-02 Date of issue... : 2012-06-06 Total
More informationIEC and/or EN Safety of information technology equipment
R904.023.1 Kontron Single Board Computer JRex entium-m 1.6G (BQBA) Customer: Kontron Embedded Modules GmbH Brunnwiesenstrasse 16 94469 Deggendorf (0991) 3 70 24-0 (0991) 3 70 24-16 The test result refers
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationE-15 Uninterruptible Power Systems (UPS)
Guideline No.E-15 (201705) E-15 Uninterruptible Power Systems (UPS) Issued date: May 9, 2017 China Classification Society Foreword This Guideline is a part of CCS Rules, which contains technical requirements,
More informationTEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools
age 1 of 77 Test Report issued under the responsibility of: TEST REORT Safety of Hand-Held Motor-Operated Electric Tools Report Reference No.... : 70.403.09.214.04-02 Date of issue... : 2012-09-03 Total
More informationAn average of one worker is electrocuted on the job every day There are four main types of electrical injuries:
Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1712057S.50A Date of issue... : 2017-04-13 Total number
More informationOperating Instructions
Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety
More informationTechnical Data. Dimensions
Model Number Features 40 mm flush 4-wire DC ATEX-approval for zone 2 and zone 22 S Technical Data specifications Switching element function PNP NO/NC Rated operating distance s n 40 mm Installation flush
More informationIn general this document presents specific safety procedures for systems with potentially lethal voltages on bare or exposed conductors.
1. Introduction All safety rules presented in this document are intended to ensure safe working conditions while working with potentially dangerous voltages. It is assumed that all personnel working with
More information3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS
3000RS PRECISION RESISTANCE STANDARD 3000 PRECISION SERIES LABORATORY REFERENCE STANDARDS 3000RS Series Precision Resistance Standard Operation Manual Version 1.40 September 2011 All product names are
More informationUV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10
our name is our principle UV- TECHNOLOGY Technical Documentation ELC N6 / ELC N8 / ELC N10 GB eta plus electronic gmbh Lauterstraße 29, D-72622 Nürtingen, Telefon +49 (0) 70 22-60 02-80, Fax +49 (0) 70
More informationOperating Instructions (Translation)
Product Description Definition The ANTARES RCU consists of the ANTARES Head Module and the ANTARES Connection Module. The ANTARES Head Module contains a CPU, communication interface and power pack. In
More informationAccessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600
Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600 Installation Guide WBP-Box-IEN103320 IMEN-WBP-BOX Version 2.0 EN SMA Solar Technology AG Table of Contents Table of Contents
More informationTEST REPORT IEC Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...
More informationPage 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.
12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...
More informationCopy of marking plate. Page 2 of 50 Report No. TRS
Copy of marking plate Page 2 of 50 Report No. TRS09030062 Page 3 of 50 Report No. TRS09030062 GENERAL INFORMATION Test item particulars (see also clause 5): Classification of installation and use... :
More informationTEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements
Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements
More informationPneumatic Isolation Module
Pneumatic Isolation Module (Cat. 2030-Pxxxxx) ATTENTION: Hazardous Voltage or other forms of energy could be present. To avoid serious injury or death: Prior to beginning the installation and wiring process,
More informationThermal-magnetic Miniature Circuit Breaker 4230-T...
Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail
More informationElectrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1
Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)
More informationLED Driver Linear / area fixed output
Driver LC 65W 4-7mA flexc lp ANCED series Product description Built-in constant current LED Driver Adjustable output current between 4 and 7 ma Max. output power 65 W Up to 94 % efficiency Nominal life-time
More information