CERTIFICATE OF ACCREDITATION

Size: px
Start display at page:

Download "CERTIFICATE OF ACCREDITATION"

Transcription

1 CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1), (2) and (3) of the said Act, I hereby certify that:- SABS COMMERCIAL SOC LTD NETFA Co. Reg. No.: 2000/013581/07 OLIFANSTFONTEIN Facility Accreditation Number: T0159 is a South African National Accreditation System accredited Testing laboratory provided that all SANAS conditions and requirements are complied with This certificate is valid as per the scope as stated in the accompanying schedule of accreditation, Annexure A, bearing the above accreditation number for ELECTRICAL PERFORMANCE TESTING The facility is accredited in accordance with the recognised International Standard ISO/IEC 17025:2005 The accreditation demonstrates technical competency for a defined scope and the operation of a laboratory quality management system While this certificate remains valid, the Accredited Facility named above is authorised to use the relevant SANAS accreditation symbol to issue facility reports and/or certificates Mr R Josias Chief Executive Officer Effective Date: 30 November 2013 Certificate Expires: 29 November 2018

2 ANNEXURE A S C H E D U LE O F A C C R E D I T A T I O N Testing Laboratory Number: T0159 Permanent Address of Laboratory: SABS Commercial SOC Ltd NETFA 43 rd Street Olifanstfontein S; E Postal Address: PO Box 144 Olifantsfontein 1665 Onsite SABS Lower Germiston Road Rosherville Johannesburg Technical Signatories: Mr JP Fourie (HV) Mr JL Monyai (MIL) Mr BD Taylor (HV & ML) Mr LAJ van den Heever (ML) Mr SS Mnisi () Mr FT Mkansi (HV) Mr LV Marumole (HV) Mr RI Ngobeni (MIL) Ms NK Ntseke () Mr MG Nkwashu (Methods marked #only) Mr ES Phewa (Methods marked * only) Mr V Mashiane (SABS 156,SABS 1524,VC 8036,SANS ,SANS ) Ms A Munhutu (SANS 156, 556-1, 767-1, & 2, ,2,11, ,3, SANS/IEC ,102,200,103,100) Ms M Chokoe ( SANS/IEC , ,200,202,103,100,102; SANS/IEC , , , , SANS 780, 60439,2) Management Signatory: Mr I Djurdjevic Tel: Fax: (011) (Lab) (011) kgaugelo.rabodiba@sabs.co.za Nominated Representative: Key: Mr J Marema HV: High Voltage Laboratory, : Short Circuit Laboratory, IL: Installations Laboratory, MIL: Materials Laboratory Tel: Fax: (012) (Mr J Marema) (012) johnson.marema@sabs.co.za Issue No.: Date of issue: Expiry date: October November 2018 Equipment/Techniques Used IL Plugs, socket-outlets and Markings on accessories VC8008:2010* socket outlet Checking of dimensions adaptors Protection against electric shock SANS :2013* Provision for earthing Terminals and terminations SANS 164-0:2016* SANS 164-1:2016* Construction of fixed socket-outlets Interlocked socket outlets SANS 164-2:2012* SANS 164-3:2013* Resistance to ageing, protection provided by enclosures and resistance to humidity Insulation resistance and electric strength Operation on earthing contacts Temperature rise Breaking capacity SANS 164-4:2013* SANS 164-5:2007* SANS 164-6:2010* SANS :2005* SANS :1995* Original date of accreditation: 01 September 2002 Page 1 of 14

3 ANNEXURE A IL Plugs, socket-outlets and Normal operation socket-outlet adaptors Force necessary to withdraw the plug Flexible cable and their connection Mechanical strength Resistance to heat Screws, current-carrying parts and connections Creepage distances, clearances and distances through sealing compound Resistance tests of insulating material to abnormal heat, fire and tracking Resistance to rusting Additional tests on pins provided with insulation sleeves IL Appliances couplers Markings on accessories VC 8012:2010 Checking of dimensions and compatibility SANS :2008 Protection against electric shock test Provision for earthing on couplers Terminals and terminations Construction of appliance couplers Moisture resistance test on couplers Insulation resistance and electric strength test Forces necessary to insert and withdraw the connector Operation on contacts Resistance to heating of different types of couplers Breaking capacity test Normal operation test Temperature rise test Cords and connections must comply with IEC 227/IEC 245:2006 IEC 227 or IEC 245 Mechanical strength test Resistance to heat and ageing test Screws, current-carrying parts and connections Creepage distance test on insulation of connectors and inlets as well as clearances and distances Materials test to fire, heat and tracking Rusting test and ferrous parts IL Ready boards Cord sets and All test included in SANS 1619 SANS 1619:2011 cord extension sets All tests included in SANS , SANS , SANS to SANS and SANS 1574 SANS SANS SANS SANS SANS 1661:2012* VC 8029:2012* SANS :2013 SANS :2008* SANS 164-0:2012 to SANS 164-6:2010 SANS 164-0:2016 SANS 1574:2004# SANS :2006*# SANS 60799:2007* SANS :2013* SANS :2007 Original date of accreditation: 01 September 2002 Page 2 of 14

4 ANNEXURE A IL Wall boxes Markings Dimensions Protection against electric shock Provision for earthing Construction Resistance to ageing, protection against ingress of solid objects and harmful ingress of water Insulation resistance and electric strength Mechanical strength Resistance to heat Creepage distance, clearance and distance through sealing compounds Resistance to insulation material to abnormal heat and fire Resistance to tracking Resistance to corrosion SANS 1085:2014 SANS :2012 IL Switches for appliances Markings VC8052:2010 Cord switches independently Protection against electric shock SANS :2009 I mounted switches Provision for earthing SANS :2011 Terminals and terminations SANS :2004 Construction Testing of mechanism Insulation resistance and dielectric strength Test of material to heating Endurance switch test Mechanical strength test Resistance to heat, fire and tracking test Resistance to rusting test IL Switches for household and Markings VC 8003:1998* Similar fixed electrical Protection against electric shock SANS :2007* installations Cord anchorage test Mechanical strength test Protection against dust, water and against humid conditions Insulation resistance and dielectric strength Endurance test Mechanical strength test Resistance to heat, fire and tracking test Resistance to rusting test Endurance test Resistance to heat, fire and tracking Ratings; Classification; Markings; Dimensions Protection against electric shock; Provision for earthing; Terminals; Constructional requirements IL Adaptors Mechanisms; Resistance to aging etc. Insulation and resistance and electric strength; Temp rise; Making and breaking capacity; Normal operation; Mechanical strength Resistance to heat; Screws, current caring parts and connection; Creepage and VC8008:2010 SANS :1995 SANS 164-1:2012 SANS 164-2:2012 SANS 164-3:2013 SANS 164-4:2013 SANS 164-5:2007 SANS 164-6:2010 Original date of accreditation: 01 September 2002 Page 3 of 14

5 ANNEXURE A IL Adaptors Mechanisms; Resistance to aging etc. Insulation and resistance and electric strength; Temp rise; Making and breaking capacity; Normal operation; Mechanical strength Resistance to heat; Screws, current caring parts and connection; Creepage and Clearances and distance through sealing compound; Resistance of insulating material to abnormal heat, to fire and to tracking; Resistance to rusting VC8008:2010 SANS :1995 SANS 164-1:2012 SANS 164-2:2012 SANS 164-3:2013 SANS 164-4:2013 SANS 164-5:2007 SANS 164-6:2010 IL Terminal blocks SANS SANS :2008 IL Light dimmers Markings on accessories SANS 1012:2006 Insulation resistance test High voltage test Endurance test Abnormal operations Operation of a switch Corrosion resistance Combustion test on material Resistance to heat test Absorption resistance of insulation materials Temperature rise test Light output test Circuit breakers and switch disconnectors Tripping limits and characteristics Dielectric properties Mechanical operations and operational performance capability Overload performance Verification of dielectric withstand Verification of temperature rise Verification of overload releases Verification of under voltage and shunt releases (if applicable) Rated service short-circuit breaking capacity Rated ultimate short-circuit breaking capacity Rated short-time withstand current Short-circuit breaking capacity at maximum short-time withstand current Short-circuit at the selectivity limit current Short-circuit at 1,1 times take-over current Short-circuit at ultimate short-circuit breaking capacity Resistance to mechanical shock on impact Rated service short-circuit breaking capacity Vibration Endurance Breaking capacity Mechanical strength Water absorption Combustion Test for stick-on labels Marking 28-day test SANS :2014 IEC :2013 SANS :2012 IEC :2012 SANS 156: 2007 VC8036:2006 SANS 556-1: 2012 AS 3111: 2009 AS 2184:1985 IEC 60898: 2003 Original date of accreditation: 01 September 2002 Page 4 of 14

6 ANNUXURE A Date of issue: 20 October 216 Circuit breakers and switch disconnectors Short-circuit performance at 1500 A Short-circuit capacity Performance at rated short-circuit capacity Performance at reduced short-circuits Mechanism Indelibility of marking Clearances and creepage distances (external parts only) Non-interchangeability Reliability of screws, current-carrying parts and connections Reliability of screw-type terminals for external conductors Protection against electric shock Clearances and creepage distances (internal parts only) Resistance to heat Resistance to abnormal heat and to fire Resistance to rusting Making and breaking capacities (1) Leakage current (2) Strength of actuator mechanism (2) Short-circuit making capacity Fuse protected short-circuit withstand Fuse protected short-circuit making SANS :2014 IEC :2013 SANS :2012 IEC :2012 SANS 156: 2007 VC8036: 2006 SANS 556-1:2012 AS/NZS 3111:2009 AS2184: 1985 IEC 60898: 2003 Portable earthing Gear and line fitting Earth leakage relays Short circuit current test Indelibility of marking Reliability of connections Protection against electric shock Dielectric properties Temperature rise Operating characteristic Mechanical and electrical endurance Behaviour of RCCB s under short-circuit conditions SANS 61230:2009 IEC 61230:2008 SANS/IEC 61284: 1997 SANS 767-1: 1982 SANS 767-2: 1983 VC8035: 1987 AS3190: 1994 Earth leakage relays Resistance to shock and impact Resistance to heat Trip free mechanism Operation at limits of rated voltage Behaviour of RCCB s in case of failure of line voltage SANS 767-1: 1982 SANS 767-2: 1983 VC8035: 1987 AS3190: 1994 High Voltage AC circuit breakers Measurement of circuit resistance Temperature rise tests Short time peak withstand current Basic short circuit duties Critical current tests Single phase short circuit tests SANS :2013 IEC :2012 IEC :2011 Original date of accreditation: 01 September 2002 Page 5 of 14

7 ANNUXURE A AC Metal enclosed switchgear Measurement of circuit resistance Temperature rise tests Short time and peak withstand current Verification of making and breaking capacity, circuit breakers and switches Verification of protection Arcing due to internal fault SANS :2012 IEC :2011 IEC : 2011 SANS :2014 IEC : 2014 SANS 1029: 2010 NRS 004:2010 Low voltage switch gear Resistance against unwanted tripping Temperature rise limits Dielectric properties Short-circuit withstand strength Effectiveness of protective circuit Clearances and creepage distances Mechanical operation Degree of protection Wiring, electrical operation Protective measures Insulation resistance Arcing due to internal fault SANS :2004 IEC :2004 SANS :2006 IEC :2005 SANS :2007 IEC :2001 SANS :2005 IEC :2004 SANS :2006 IEC :2006 SANS :2012 IEC :2011 SANS :2012 IEC :2011 SANS :2013 IEC :2012 SANS :2014 IEC :2012 SANS :2012 IEC :2012 SANS :2007 SANS :2008 SANS :2008 SANS 61641:2008 IEC/TR 61641:2008 SANS 60890:2007 IEC 60890:1987 SANS :2013 IEC :2012 SANS : 2012 SANS : 2014 AC Disconnectors and earthing switches Temperature rise Measurement of resistance of main circuit Short time and peak withstand current Short circuit making performance SANS :2013 IEC : 2013 SANS :2012 IEC : 2011 IEC : 2011 HV AC switch-fuse combinations Measurement of circuit resistance Temperature rise SANS :2013 IEC : 2012 IEC :2011 HV switches Measurement of circuit resistance Temperature rise Short time and peak withstand current Making and breaking tests SANS :2012 IEC : 2011 IEC : 2011 Original date of accreditation: 01 September 2002 Page 6 of 14

8 ANNEXURE A HV switches Measurement of circuit resistance Temperature rise Short time and peak withstand current Making and breaking tests SANS :2012 IEC : 2011 IEC : 2011 Reactors Ability to withstand short circuit IEC 60289: 1988 Cable joints and terminators Thermal short circuit Mechanical short circuit protection IEC : 1981 SANS :2013 IEC :2010 NRS 053: 2008 HD 629: 2002 BS 6910:1989 Insulators Temperature cycling tests SANS 60660:1999 IEC 60660: 1999 SANS 61109:2008 IEC 61109: 2008 Dry type power transformers: power transformers; distribution transformers Short-circuit test Temperature-rise test IEC 60726: 1982 SANS :2011 IEC :2011 SANS :2011 IEC :2011 SANS :2006 IEC :2006 SANS :2008 IEC :2007 SANS :2001 IEC :2001 SANS :2005 IEC :2004 SANS 780: 2009 High Voltage AC contactors and contactor-based motor starters Overload current withstand Short-circuit making and breaking test Verification of co-ordination with SCPDS SANS :2012 IEC : 2011 IEC : 2011 Expulsion fuses Breaking tests SANS :2008 IEC : 2008 Current-limiting fuses Breaking tests SANS :2010 IEC : 2009 Inductive voltage transformers Short-circuit withstand capability test IEC : 2003 SANS : 201 Bushings Verification of dimensions Temperature rise test Dynamic current withstand IEC 60137:2010 Original date of accreditation: 01 September 2002 Page 7 of 14

9 ANNEXURE A AC Metal enclosed switchgear Dielectric tests on auxiliary and control circuits Gas insulated switchgear Temperature rise test Measurement of resistance of the main circuit Short time peak withstand current tests Verification of making and breaking capacities Test under conditions of arcing due to an internal fault Dielectric tests on auxiliary and control Circuits Current transformers Short- time current tests Temperature rise test Verification of terminal markings HV Current transformers Voltage withstand test Lightning impulse test Partial discharge test HV AC Metal enclosed switchgear Power frequency voltage tests Lightning impulse test Partial discharge test Dielectric tests on auxiliary and control circuits HV Conductors Radio Interference Corona HV Inductive voltage transformers Lightning impulse test on primary winding Wet tests on outdoor transformers Verification of terminal markings Switching impulse test Partial discharge test Measurement of tan δ SANS :2012 IEC : 2011 IEC : 2011 SANS :2014 IEC : 2014 SANS 1029: 2010 NRS 004:2010 SANS :2012 IEC : 2011 IEC : 2011 IEC : 2012 IEC : 2007 IEC : 2012 AS 1675: 1986 IEC :2005 IEC :2013 IEC :2013 IEC : 2013 AS 1675 IEC :2012 IEC :2012 IEC :2014 SANS 1029:2010 IEC 61284:1997 CISPR 18-2 : 2010 IEC 61284:1997 IEC IEC :2013 IEC :2013 IEC :2013 HV AC Disconnectors and earthing Power frequency voltage tests IEC :2013 switches Lightning and switching impulse voltage IEC :2012 tests IEC :2012 Partial discharge CISPR 18-2: 2010 Dielectric tests on auxiliary and control circuits Radio interference voltage

10 Original date of accreditation: 01 September 2002 Page 8 of 14 ANNEXURE A Equipment/Techniques Used HV High Voltage AC circuit Power frequency voltage tests IEC :2013 breakers Lightning and switching impulse voltage IEC :2012 tests CISPR 18-2: 2010 Partial discharge Radio interference voltage HV HV AC switch-fuse Power frequency voltage tests IEC :2013 combinations Lightning and switching impulse voltage IEC :2012 tests Partial discharge Dielectric tests on auxiliary and control circuits HV HV switches Power frequency voltage tests IEC :2012 Lightning and switching impulse voltage IEC :2012 tests Partial discharge Dielectric tests on auxiliary and control circuits HV Electrical distribution Standard wet tests IEC :2011 equipment AC voltage tests up to 1200 kv IEC : 2010 Lightning impulse voltage tests up to 4 MV Switching impulse voltage tests up to 3 MV Impulse current tests 1/20 μs, 8/20 μs up to 40 ka Impulse current tests 8/20 μs up to 40 ka Phase to phase lightning and switching impulse tests Phase to phase power frequency tests Insulation co-ordination HV Cable joints and terminators Withstand voltage (AC) IEC :2005 Partial discharge test IEC :2013 Impulse voltage NRS 053:2008 Load cycling with voltage HD 623 S1: 1996 DC voltage test HD 629: 2006 Load cycling (no voltage) BS 6910: 1988 Load cycling (in water bath) Insulation resistance Voltage withstand in water bath Leak tightness Voltage withstand under wetting Voltage withstand under artificial rain HD 691 HV Insulators Impulse withstand and flashover SANS 177:2004 Wet and dry power-frequency withstand IEC : 2006 flashover IEC : 1996 Radio interference IEC 60383:1993 Verification of dimensions Puncture voltage withstand test IEC 60437:1997 CISPR 18-2: 2010 Partial discharge extinction voltage test IEC 60660:1999 Lightning impulse puncture test IEC 61109:2008 Steep-front impulse voltage test Wet switching impulse test Corona test Original date of accreditation: 01 September 2002 Page 9 of 14

11 ANNEXURE A Equipment/Techniques Used HV Surge arrestors Power-frequency voltage sparkover test IEC :2005 Front-of-wave voltage impulse sparkover Test Switching impulse sparkover voltage/time curve test Residual voltage test Current impulse withstand Operating-duty test Insulation withstand tests on arrestor housing Residual voltage test Long duration current impulse withstand test line discharge class 1 & 2 only SANS/IEC :2006 IEC :2011 HV Cables with extruded solid Power factor as a function of voltage IEC :2013 dielectric Power factor as a function of temperature IEC 60840:2006 Partial discharge test SANS 1339:2015 Bending test Heating cycle VC 8077:2003 Impulse voltage test High voltage withstand Capacitance HV Bushings Verification of dimensions Wet or dry lightning or switching impulse Tests Capacitance and tan δ Partial discharge HV Gas insulated switchgear Dielectric tests Radio interference voltage test Power-frequency voltage tests on main Circuit Dielectric tests on auxiliary and control Circuits Partial discharge measurement Voltage tests on the main circuit on site Lightning impulse test Switching impulse test IEC 60137:2010 SANS 1035 IEC :2012 IEC :2012 IEC :2012 CISPR 18-2: 2010 HV Paper cables Bending test Power factor/temperature test IEC :2005 IEC :1981 Impulse voltage test SANS 97:2012 Voltage withstand VC 8077:2003 Power factor HV Rubber cables Partial discharge test SANS :2008 HV Dry type power transformers: Lightning impulse test IEC :2004 HV Earth leakage relays Impulse voltage resistance of insulation SANS 767-1:1982 SANS 767-2:1983 VC8035;1987 AS3190: 1994 Original date of accreditation: 01 September 2002 Page 10 of 14

12 ANNEXURE A ML Cables with extruded solid dielectric Compliance with constructional requirements Dimensions Tensile test and elongation of insulation before ageing Tensile test and elongation of insulation after ageing (Air oven) Tensile test and elongation of sheath before ageing Tensile test and elongation of sheath after ageing (Air oven) Tensile test and elongation of sheath after immersion in oil Pressure at high temperature (Insulation) Pressure test at high temperature (Sheath) Bending at low temperature (Insulation) Heat shock (Insulation) Heat shock (Sheath) Hot set test Flame retardance Thermal stability Shrinkage Volume resistivity Insulation resistance constant Resistivity of semi-conducting layer Bending at low temperature (Sheath) Elongation at low temperature (Sheath Elongation at low temperature (Insulation) Loss of mass IEC :2004 IEC :1997 IEC :2013 IEC 60840:2006 SANS 1339:2015 SANS :2007 SANS :2015# SANS :2015# SANS :2014# SANS :2015# SANS :2015# VC 8077:2003 ML Cable joints and terminations Low voltage accessories BS EN 50393:2006 ML Paper cables Electrical resistance of conductors IEC :2005 IEC :1981 Dimensions SANS 97:2012 Bending test VC 8077:2003 Electric cables Single core arc welding cables SANS 1576:2008# ML PVC cables Electrical resistance of conductors Voltage withstand (Cores) Voltage withstand (Complete cable) 70ºC Compliance with constructional provisions Dimensions Tensile strength of insulation before ageing Tensile strength of insulation after ageing Loss of mass (Insulation) Tensile strength of sheath before ageing Tensile strength of sheath after ageing Loss of mass (Sheath) Bending at low temperature (Insulation) Bending at low temperature (Sheath) IEC :2006 IEC :2006 IEC :2006# SANS :2012 SANS :2012 SANS :2016 SANS :2012# BS 6004:2005

13 Elongation at low temperature Original date of accreditation: 01 September 2002 Page 11 of 14 ANNEXURE A ML Impact test at low temperature Heat shock test (Insulation) Heat shock test (Sheath) Flame retardance Test for non-contamination Pressure test at high temperature (Insulation) Pressure test at high temperature (Sheath) Flexing test Static flexibility test VC 8006:2010 VC 8075:2003 ML Dielectric sheet and plate Tensile properties ASTM D229: 2013 materials Dielectric strength Permittivity and dissipation factor Insulation resistance and resistivity Warp or twist ML Pressure sensitive materials Width ASTM D1000: 2010 Thickness SANS 122:2007 Length of tape in a roll Breaking strength and elongation Adhesion strength Unwind force Flagging Thermosetting properties Dielectric breakdown voltage Insulation resistance at high humidity Effect of accelerated ageing on dielectric breakdown voltage Flammability Bond strength after solvent immersion Oil resistance Puncture resistance ML Conductors Electrical resistance IEC 60228:2004 Compliance with constructional requirements Dimensions SANS 523:2009 SANS 1411:2008 SANS 1411:1-7:2008# SANS 182-1:2008 # SANS 182-2:2008# SANS 182-5:2008 VC8075 VC8006 Original date of accreditation: 01 September 2002 Page 12 of 14

14 ANNEXURE A ML Rubber cables Durability of colours and markings Dimensions SANS :2008 SANS :2008 SANS :2013 Solderability of untinned conductors SANS :2013# SANS :2013# Electrical resistance of conductors VC 8006:2010 Voltage test on completed cables Voltage test on cores Insulation resistance at elevated temperatures Flexing test Static flexibility test Tensile test and elongation of insulation before ageing Tensile test and elongation of insulation after ageing test (Air oven) Tensile test and elongation of sheath before ageing Tensile test and elongation of sheath after ageing test (Air oven) Tensile test and elongation of sheath after immersion in oil Hot set test (Insulation) Hot set test (Sheath) Pressure test at high temperature (Insulation) Bending at low temperature (Sheath) Elongation at low temperature (Sheath) Flame retardance Test for resistance to heat ML Aerial bundle cable All tests SANS :2009# SANS :2014# AS/NZS 3560 Part1:1991, excluding heat radiation test SANS :2016 ML Dielectric materials Dielectric breakdown voltage of solid ASTM D149:2013 electrical insulation BS 2050:1978 Dielectric strength of solid electrical ISO 284:2012 insulation NCB 245 AC loss characteristics of solid electrical insulation SANS 971:2013 Permittivity of solid electrical insulation DC resistance or conductance of insulating materials Volume resistivity and surface resistance Electrical resistance only IEC 60093:1980 SANS 1287:2007 Original date of accreditation: 01 September 2002 Page 13 of 14

15 ANNEXURE A ML Enamelled wire Dimensions SANS :2014 SANS :2014 Electrical resistance SANS :2014 SANS :2007 Springiness SANS :2010 SANS :2012 Mandrel winding test SANS :2012 SANS :2011 Stretching test SANS :2014 Jerk test Peel test Heat shock Cut-through Resistance to solvents Breakdown voltage Continuity of coverage (L.V. only) High temperature failure Packaging ML Winding wires Dimensions Electrical resistance Springiness Mandrel winding test Stretching test Jerk test Peel test Adherence test Solvent test Breakdown voltage Continuity of covering (L.V. only) Heat shock Cut-through test Packaging IEC :1996 IEC :2010 IEC :2014 IEC :2006 IEC :2012 IEC :2013 SANS :2014 SANS :2014 SANS :2014 SANS :2007 SANS :2010 SANS :2012 SANS :2012 SANS :2011 SANS :2014 HV (Onsite) Power transformers and distribution transformers Lightning impulse testing IEC :2014 SANS :2014 IEC :2004 SANS :2004 IEC :2006 SANS :2006 SANS 780:2009 Original date of accreditation: 01 September 2002 Page 14 of 14 ISSUED BY THE SOUTH AFRICAN NATIONAL ACCREDITATION SYSTEM

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme) Page 1 of 6 Site(s) applicable to the recognition: Central Power Research Institute Prof Sir C.V. Raman Road P.B. No. 8066 Sadashivanagar Sub-P.O. Bangalore 560 080 India Central Power Research Institute

More information

List of Mandatory Commercial Documents ITEM DESCRIPTION REQUIRED ITEM DRAWING DOCUMENTS NAME REQUIRED ITEM TEST DOCUMENTS NAME

List of Mandatory Commercial Documents ITEM DESCRIPTION REQUIRED ITEM DRAWING DOCUMENTS NAME REQUIRED ITEM TEST DOCUMENTS NAME Terms and Conditions : 1) Before proceed please confirm material documents and test documents are available with you. 2) Vendor Document Verification Registration Fee Rs.5000 + payment gateway charges,

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3 TITLE SPECIFICATION FOR MEDIUM VOLTAGE DATE: FEBRUARY 2015 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 NORMATIVE S... 3 3 DEFINITIONS AND ABBIATIONS... 3 4 REQUIREMENTS...

More information

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy. Energy Transmission & Distribution Services - Italy SVEPPI laboratory...our services for your success. Answers for energy. ...our services for your success ENERGY - T&D Services Experience teaches us that

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED PART B-07 TITLE: SERVICE CONNECTIONS SPECIFICTION NO: B-07 INCEPTION DATE: AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) AMENDMENTS / REVISIONS DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY

VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Electric Large Laboratories Ltd. H-1158-Budapest, Vasgolyó utca 2-4. HUNGARY VEIKI-VNL Ltd. VEIKI-VNL Electric Large Laboratories Ltd. is an independent accredited testing member laboratory of

More information

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING 1 DEPARTMENT OF ELECTRICAL ENGINEERING Introduction to High Voltage Testing It is essential to ensure that the electrical equipment is capable of withstanding the overvoltages that are met within the service.

More information

Energy Division. PCA Single Column Polymeric Surge Arrester

Energy Division. PCA Single Column Polymeric Surge Arrester Energy Division PCA Single Column Polymeric Surge Arrester Bowthorpe EMP pioneered the development of the polymeric composite housed surge arrester in the early 1980 s and since 1986 has a proven service

More information

Independent Testing Laboratory for High Voltage Equipment

Independent Testing Laboratory for High Voltage Equipment T E S T I N G L A B O R A T O R Y Independent Testing Laboratory for High Voltage Equipment 1 CHALLENGING ENVIRONMENT The primary concern for utilities is to ensure grid reliability, efficiency, and security.

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-31488-0 SOUTH AFRICAN NATIONAL STANDARD Switchgear Metal-enclosed ring main units for rated a.c. voltages above 1 kv and up to and including 36 kv WARNING This document references other

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Issue 3 2012 SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) www.energynetworks.org 2012 Energy Networks

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

power cable accessories

power cable accessories power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60470 Second edition 1999-10 High-voltage alternating current contactors and contactor-based motor-starters Contacteurs pour courants alternatifs haute tension et démarreurs

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11068-09-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 10.07.2014 to 09.07.2019 Holder of certificate: Karlsruher

More information

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS TITLE SPECIFICATION FOR POLE- MOUNTED DATE: JUNE 2006 PAGE: 1 OF 17 TABLE OF CONTENTS Page FOREWORD...2 INTRODUCTION...3 1 SCOPE...3 2 NORMATIVE S...3 3 DEFINITIONS AND ABBIATIONS...3 4 REQUIREMENTS...3

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE

H U B B ELL L ABOR ATORIES CAPABILITY GUIDE H U B B ELL L ABO R ATO R I E S CAPABILITY GUIDE INTRODUCTION Hubbell Power Systems, Inc. manufactures a wide variety of products for the electric utility, telecommunications, civil construction, transportation,

More information

HMI, APRIL, Test Laboratories in Ratingen

HMI, APRIL, Test Laboratories in Ratingen HMI, 24.-28. APRIL, 2017 Test Laboratories in Ratingen Test Laboratories Ratingen Overview Basic Features Flexible Independent Well experienced in testing of medium and low voltage equipment (testing since

More information

3EK7 Medium Voltage Silicone Insulated Surge Arresters

3EK7 Medium Voltage Silicone Insulated Surge Arresters 3EK7 Medium Voltage Silicone Insulated Surge Arresters Power Transmission and Distribution Setting new Standards The 3EK7 s mechanical features: Glass-collared MOV, Silicone rubber housing, FRP rods and

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20575-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2018-03-05 to 2021-07-28 Holder of certificate: innogy

More information

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement. INTRODUCTION The Power Systems 44 kv MiniSub TM is the most compact system at this voltage available. Utilizing a deadfront termination and lightning arrestor setup, it eliminates the line top or side

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification

More information

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society Guideline No.: E-07(201610) E-07 TRANSFORMERS Issued date: October 28,2016 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. 1. SCOPE:- This specification covers the manufacture, testing and supply of 33KV 200 Amps, H.G. Fuse sets 2. The 33 KV H.G. Fuses shall be suitable

More information

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK 1ZSC563-AAA en, Rev. 2 Resin Impregnated Paper Bushing, Oil to SF 6, Type GSBK Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society Guideline No.: E-07(201712) E-07 TRANSFORMERS Issued date: December 26, 2017 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2 The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 2 SWITCHBOARDS Overview Also called Switchgear and Controlgear Assembly

More information

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders Applications HV HRC (high-voltage high rupturing capacity) fuses are used for short circuit protection in high-voltage switchgear for the 50 to 60 Hz frequency range Distribution transformers up to 2000

More information

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide 1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide 1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications 4-O 1/15 Combined Current and Voltage Instrument Transformer CVS-P-4-O Technical Specifications Rev. Date Revision Description Prepared by Checked by Approved by 0 3/10/15 First Issue E. Scala L. Peretto

More information

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

Menu. Home About this portal Latest updates. Print Save  Resource detail Citations. Table of Contents Menu Home About this portal Latest updates Print Save Email Resource detail Citations AS/NZS 60898.1:2004 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2)(b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

TABLE OF CONTENTS FOREWORD...3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PORTABLE DATE: JULY 2006 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD...3 INTRODUCTION...4 1 SCOPE...4 2 NORMATIVE S...4 3 DEFINITIONS AND ABBIATIONS...4 4 REQUIREMENTS...5 4.1

More information

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide 1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

High Voltage Technology & Testing

High Voltage Technology & Testing The Power of Trust. The Future of Energy. HIGH VOLTAGE TESTING Qualification testing, condition assessment, and forensic analysis Manufacturers and utility users of high-voltage electrical equipment face

More information

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv

3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv 3M Cold Shrink QT-III Silicone Rubber Termination Kits 7640-T and 7650-T Series 5, 8, 15, 25/28 and 35 kv Data Sheet September 2014 Description 3M Cold Shrink QT-III Silicone Rubber Termination Kits, 7640-T

More information

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide 1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,

More information

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society Guideline No.: E-07(201501) E-07 TRANSFORMERS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection and

More information

H e a t s h r i n k P r o d u c t G u i d e

H e a t s h r i n k P r o d u c t G u i d e P o w e r P r o d u c t s H e a t s h r i n k P r o d u c t G u i d e Introduction HellermannTyton is a world leader in providing systems and solutions for heatshrink applications. HellermannTyton utilises

More information

High Voltage and Extra High Voltage Cables

High Voltage and Extra High Voltage Cables High Voltage and Extra High Voltage Cables GUIDE TO THE SELECTION OF EHV AND HV CABLES EHV and HV cables are specially designed on the basis of the project data. To determine appropriate design of a high

More information

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV.CAPACITOR BANK 1.0 SCOPE: This specification covers

More information

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide 1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

j Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

j Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK j Schedule of Accreditation Laboratory locations: Ridley Street lyth Northumberland NE24 3AG United Kingdom ORE Catapult Development Services Limited a subsidiary of Contact: Geoff Richardson Tel: +44

More information

LIST OF PUBLISHED STANDARDS

LIST OF PUBLISHED STANDARDS Report : 08-0-6 Page o : Of 5 LST OF PUBLSHED STDRDS Total Count: 78 umber SS umber pproved mendment SBS/TC 066 SS 97:07 7.0 Electric cables - mpregnated paper-insulated 07-0-7 metal-sheathed cables for

More information

8DJ. Maintenance-free for lifetime

8DJ. Maintenance-free for lifetime 8DJ Maintenance-free for lifetime Energy Distribution Welcome! Page 2 October 1 st 2008 8DJ Main Applications for Medium-Voltage Switchgear Power generation Power stations G Power transmission High and

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide 1ZSE 2750-112 en, Rev. 3 Wall bushings, type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF FORCE METROLOGY:- CALIBRATION OF UNIAXIAL TESTING MACHINES Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane

More information

Key elements of the AS3000 Wiring standards and some of the recent changes.

Key elements of the AS3000 Wiring standards and some of the recent changes. Key elements of the AS3000 Wiring standards and some of the recent changes. Dean of Engineering Steve Mackay Worked for 30 years in Industrial Automation 30 years experience in mining, oil and gas, electrical

More information

Item 1: Contents of the complete training & CV of the lecturer

Item 1: Contents of the complete training & CV of the lecturer Course DESIGN CONCEPTS + software SwitchgearDesign for SWITCHGEAR, SWITCHBOARDS, BUSDUCTS & SUBSTATIONS" Item 1: Contents of the complete training & CV of the lecturer Presented by Sergio Feitoza Costa

More information

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12) s www.siemens.com/energy Auxiliary Relay (7PJ) and Trip Relay (7PJ2) Better protection and more efficiency for your power system Answers for infrastructure and cities. Auxiliary Relay and Trip Relay Catalogue

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH MAHARASHTRA STATE ELECTRICITY DISTRIBUTION COMPANY LTD. PAGE 1 OF 7 TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH 1.0 SCOPE:

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

3EK7 Distribution Class Surge Arresters. Answers for energy.

3EK7 Distribution Class Surge Arresters. Answers for energy. 3EK7 Distribution Class Surge Arresters Answers for energy. Siemens at Your Service As a global leader of the electronics industries, Siemens has been active in the fields of power transmission and distribution

More information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: 4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:

More information

Distribution transformers Efficiency over life-cycle

Distribution transformers Efficiency over life-cycle Distribution transformers Efficiency over life-cycle ABB a global leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

Metal Clad Switchgears

Metal Clad Switchgears SNC Series Metal Clad Switchgears > up to 36 kv Rated Voltage > up to 2500 A Rated Current > up to 40 ka Rated Short Time Withstand Current > LSC-2B, PM, AFLR > In Confirmity with IEC 62271-1, 100, 102,

More information

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC

BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) ENERGY /// MEH SURGE ARRESTERS IEC BOWTHORPE EMP MEH SURGE ARRESTERS (IEC) GENERIC TECHNICAL DATA Maximum system voltage U m 800 System voltage U s 750 Nominal discharge current ka 20 High current impulse (4/10 µs) ka 100 Arrester class

More information

FAQ S. Main Switchboard Design Criteria. ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS

FAQ S. Main Switchboard Design Criteria.   ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS FAQ S Main Switchboard Design Criteria h ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS www.electricalswitchboards.com.au Main switchboard Design criteria Q: What is the Australian standard for main

More information

Surge arrester POLIM-H..SD

Surge arrester POLIM-H..SD Data sheet Surge arrester POLIM-H..SD Technical data Classification according to EN 50526-1 and IEC 62848-1 Nominal discharge current I n (8/20 µs) 10 ka peak Class DC-B High current impulse I hc (4/10

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

The vacuum circuit breaker for commercial buildings, industrial plants and utilities The vacuum circuit breaker for commercial buildings, industrial plants and utilities EasyPact EXE The easy choice for more value 2 EasyPact EXE EasyPact EXE, a medium voltage vacuum circuit breaker optimizing

More information

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system. MV Switchgear for CGMCOSMOS Fully gas insulated modular and compact (RMU)system Up to 24 kv Up to 27 kv mediumvoltage mediumvoltageag AG Langackerstrasse Langackerstrasse 25 25 CH CH 6330 6330 Cham Cham

More information

Technical Guarantees For Electrical Materials & Equipments 1 Technical Guarantees No. IDT_1600 22/0.4 KV Low Losses, 3 phase, Indoor Distribution Transformer 1600 KVA Rating No Description Unit Requirements

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls 11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the

More information

34-SDMS-02 SPECIFICATIONS FOR

34-SDMS-02 SPECIFICATIONS FOR SPECIFICATIONS FOR M V & L V FUSE LINKS This specification is property of SEC and subject to change or modification without any notice TABLE OF CONTENTS 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE

More information

Collection of standards in electronic format (PDF) 1. Copyright

Collection of standards in electronic format (PDF) 1. Copyright Collection of standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance

More information

Technical Specification of GECOL. Packaged Transformers

Technical Specification of GECOL. Packaged Transformers GES 26211 Technical Specification of GECOL Packaged Transformers (Revision history) Issued on: Jan. 01, 2007 General Electricity Company of Libya Contents 1 SCOPE AND SERVICE CONDITIONS... 6 1.1 SCOPE...

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

3EK7 Distribution Class Surge Arresters. Answers for energy.

3EK7 Distribution Class Surge Arresters. Answers for energy. 3EK7 Distribution Class Surge Arresters Answers for energy. Siemens at Your Service As a global leader of the electronics industries, Siemens has been active in the fields of power transmission and distribution

More information

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction. HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After

More information

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT

Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation Edition DRAFT Date of publication: 1 November 2016Not yet published Issued by: Mark Wogan, Manager Energy Safety WorkSafe New ZealandNot yet issued Electric Vehicle Charging Safety Guidelines Part 2: Selection and Installation

More information

3 TM Cold Applied Barrier Boot System

3 TM Cold Applied Barrier Boot System M Technical Information : Barrier Boot TM Cold Applied Barrier Boot System For rated voltages 6.5/11(12) kv and 8.7/15(17.5) kv 92-EE 717-1 Product Description The Cold Applied Barrier Boot System consist

More information

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance M E T A L - C L A D S W I T C H G E A R Safe and Reliable Flexible, Compact Design Easy Installation and Maintenance We build a better future! Hyundai HMS medium-voltage metal-clad switchgears and control-gears,

More information

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE hvgrid-tech designs and manufactures high voltage cable accessories for all types of cable systems, ranging from 69 kv to

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

TEKNISK RIKTLINJE TR05-10E

TEKNISK RIKTLINJE TR05-10E Notes Change notes Date 1 (A) Revision of standards and new template 09 / 07 2010 2 Template changed.clause. 10.5.1.4 support clamp inserted. Clause 10.5.4.2 creepage text revised. Clause 10.6.7 Dry inserted

More information

33KV INDOOR SWITCHGEAR

33KV INDOOR SWITCHGEAR 33KV INDOOR SWITCHGEAR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:

More information

Glass insulators for kv overhead lines and substations. Global Insulator Group

Glass insulators for kv overhead lines and substations. Global Insulator Group Global Insulator Group 6-210 Katusepapi, Tallinn, 11412, Estonia tel +372-622-8118, fax +372-622-8119, cell +372 522-3551 e-mail: ved@gig-group.com, puchkov@gig-group.com www.gig-group.com Glass insulators

More information

Pretest Module 29 High Voltage Unit 1

Pretest Module 29 High Voltage Unit 1 Pretest Module 29 High Voltage Unit 1 1. Is a person qualified to work on high-voltage installations when this module is completed? 2. What is the code definition of high-voltage? 3. What is the IEEE definition

More information

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB

SafeLink The Ultimate RMU. Rex de Bruyn PTMV New Zealand. ABB Ltd - Page 1 ABB Rex de Bruyn PTMV New Zealand SafeLink The Ultimate RMU Ltd - Page 1 TheSafe Range of Ring Main Switchgear SafeLink : 12kV Compact Fuse Technology SafeRing : 12-24kV Fuse & Circuit Breaker Technology SafePlus

More information

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com TGOOD produces over 5000 switchgear units annually for projects around the globe SOLUTION OVERVIEW For use in affordable air insulated

More information

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv Three-phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv 06B1-E-0020 Small Space Requirement, High Reliability and Safety ー 72.5 to 145kV GIS, SDH714 The number of application

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS Design The Sabre VRN2a is a compact SF6 insulated Vacuum Ring Main Unit (RMU). The unit can be mounted to the smallest distribution transformer or be sited in

More information