1 Issue Date: Page 1 of 1 Report Reference # ASL COVER PAGE FOR TEST REPORT Test Item Description: Notebook PC Model/Type Reference: MS-16Y1 Rating(s): 19Vdc, 3.42A or 19Vdc, 4.74A Standards: IEC :2005, Second Edition and/or EN :2006 Applicant Name and Address: Factory Location(s): PEGATRON CORP 5TH FL, 76, LIGONG ST, BEITOU DISTRICT, TAIPEI 112, TAIWAN PROTEK (SHANGHAI) LTD 3768 XIU YAN RD KANG QIAO TOWN PU DONG NEW DISTRICT SHANGHAI CHINA This Report includes the following parts, in addition to this cover page: 1. Specific Technical Criteria 2. Clause Verdicts 3. Critical Components 4. Test Results 5. Enclosures a. National Differences (21 pages) b. Photographs (28 pages) c. Schematics + PWB (5 pages) d. Manuals (3 pages) e. Miscellaneous (7 pages) All applicable tests according to the above standard(s) have been carried out. Test results are valid only for the tested equipment. This Test Report can be reproduced only in whole. Amendments and corrections can be reproduced only with the original CB Test Report. Written permission from is required if the test report is copied in part.

2 Issue Date: Page 1 of 50 Report Reference # ASL Report Reference No... : Test Report issued under the responsibility of: TEST REPORT IEC :2005 (2nd Edition) and/or EN :2006 Information technology equipment - Safety - Part 1: General requirements ASL Date of issue... : Total number of pages... : 50 CB Testing Laboratory... : Universal Standard Service, Inc. Address... : 8F-1, No. 266, Sec. 1, WenHua 2nd Road, Lin Kou Shiang 244, Taipei County, Taiwan Applicant's name... : Address... : Test specification: PEGATRON CORP 5TH FL, 76, LIGONG ST, BEITOU DISTRICT, TAIPEI 112, TAIWAN Standard... : IEC :2005, Second Edition and/or EN :2006 Test procedure... : Non-standard test method... : Test Report Form No.... : Test Report Form originator... : CB Scheme IECEN60950_1C SGS Fimko Ltd Master TRF... : Copyright c 2006 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. If this test Report is used by non-iecee members, the IECEE/IEC logo shall be removed. This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02. Test item description... : Trade Mark... : Model/Type reference... : Manufacturer... : Notebook PC MS-16Y1 MICRO-STAR INTERNATIONAL CO., LTD NO. 69, Li-De St, Jung He city,taipei Hsieh, Taiwan. Rating... : 19Vdc, 3.42A or 19Vdc, 4.74A

3 Issue Date: Page 2 of 50 Report Reference # ASL Testing procedure and testing location: [x] CB Testing Laboratory Testing location / address... : Universal Standard Service, Inc. 8F-1, No. 266, Sec. 1, WenHua 2nd Road, Lin Kou Shiang 244, Taipei County, Taiwan [ ] Associated CB Test Laboratory Testing location / address... : Tested by (name + signature)... : Chia Chang Approved by (+ signature)... : Andy Cheng [ ] Testing Procedure: TMP Tested by (name + signature)... : Approved by (+ signature)... : Testing location / address... : [ ] Testing Procedure: WMT Tested by (name + signature)... : Witnessed by (+ signature)... : Approved by (+ signature)... : Testing location / address... : [ ] Testing Procedure: SMT Tested by (name + signature)... : Approved by (+ signature)... : Supervised by (+ signature)... : Testing location / address... : [ ] Testing Procedure: RMT Tested by (name + signature)... : Approved by (+ signature)... : Supervised by (+ signature)... : Testing location / address... :

4 Issue Date: Page 3 of 50 Report Reference # ASL Summary of Testing: No tests were conducted Summary of Compliance with National Differences: AT, AU, BE, BR, CA, CH, CZ, DE, DK, ES, EU, FI, FR, GB, GR, HU, IE, IT, JP, KR, NL, NO, PL, PT, RO, SE, SG, SI, SK, UA, US

5 Issue Date: Page 4 of 50 Report Reference # ASL Notebook: Copy of Marking Plate

6 Issue Date: Page 5 of 50 Report Reference # ASL Battery pack:

7 Issue Date: Page 6 of 50 Report Reference # ASL Test item particulars : Equipment mobility...: Connection to the mains...: Operating condition...: transportable No direct connection continuous Access location : operator accessible Over voltage category (OVC)...: Mains supply tolerance (%) or absolute mains supply values...: Tested for IT power systems...: IT testing, phase-phase voltage (V)...: Class of equipment...: Considered current rating (A)...: -- OVC I Not directly connected to the mains Pollution degree...: PD 2 IP protection class...: Altitude during operation (m)...: Altitude of test laboratory (m)...: Mass of equipment (kg)...: Possible test case verdicts: Class III (supplied by SELV) IP X0 Up to 2000m Up to 2000m 2.8 kg - test case does not apply to the test object...: N / A - test object does meet the requirement...: P() - test object does not meet the requirement...: F(Fail) Testing: Date(s) of receipt of test item...: Date(s) of Performance of tests...: General remarks: N / A N / A The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a point is used as the decimal separator. Refer to the Cover Page For Test Report for a list of all Factory Locations. GENERAL PRODUCT INFORMATION: Report Summary All applicable tests according to the referenced standard(s) have been carried out. Product Description

8 Issue Date: Page 7 of 50 Report Reference # ASL The equipment is Notebook PC for use in information technology equipment. The equipment total overall see appended miscellaneous ID 7-02 for detail. For motherboard type A15HC: Electrical components are mounted on PWB which is enclosed by plastic Enclosure and accompanied with one HDD, two USB3.0 ports, two USB2.0 ports, one VGA port, one RJ45 port, one HDMI port, two Audio ports and one card reader. Mother board type A15HC was provided two construction. Construction A without VGA-chip use power rating 19Vdc, 3.42A only; Construction B with VGA-chip use power rating 19Vdc, 4.74A only. Model Differences Additional Information No tests were conducted due to this test report should be copy from ASL , issued , with CB Certificate No. (DK-21362), issued , ASL , issued , with CB Certificate No. (DK A1), issued and modify below items: 1. Add Trade Mark: 2. Replace Model name from A15xxxx to MS-16Y1, the new model MS-16Y1 is identical to A15xxxx except for model designation. 3. Replace Manufacturer name from PEGATRON CORP/5TH FL, 76, LIGONG ST, BEITOU DISTRICT, TAIPEI 112, TAIWAN to MICRO-STAR INTERNATIONAL CO., LTD / NO. 69, Li-De St, Jung He city,taipei Hsieh, Taiwan The latest version of CB Bulletin on IECEE website has been taken into account and considered compliant. The label is a draft of an artwork for marking plate pending approval by National Certification Bodies and it shall not be affixed to products prior to such an approval. Technical Considerations The product was submitted and evaluated for use at the maximum ambient temperature (Tma) permitted by the manufacturer s specification of: 35 o C The product was investigated to the following additional standards: EN :2006+A11:2009 (which includes all European national differences, including those specified in this test report). The following circuit locations (with circuit/schematic designation) were investigated as a limited power source (LPS): USB connectors, Speaker and HDMI connector. (Other connectors are classified as data ports only.) The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual

9 Issue Date: Page 8 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict 1 GENERAL 1.5 Components General Comply with IEC or relevant component standard (see appended table 1.5.1) Evaluation and testing of components Certified components are used in accordance with their ratings, certifications and they comply with applicable parts of this standard. Components not certified are used in accordance with their ratings and they comply with applicable parts of IEC and the relevant component standard. Components, for which no relevant IEC-standard exists, have been tested under the conditions occurring in the equipment, using applicable parts of IEC Thermal controls No thermal controls Transformers No isolating transformer in the equipment Interconnecting cables Interconnecting cables comply with the relevant requirements of this standard Capacitors bridging insulation Evaluated in power supply approval Resistors bridging insulation Resistors bridging functional, basic or supplementary insulation Resistors bridging double or reinforced insulation between a.c. mains and other circuits Resistors bridging double or reinforced insulation between a.c. mains and antenna or coaxial cable Accessible parts Components in equipment for IT power systems Class III equipment Surge suppressors Class III equipment General Protection of VDRs

10 Issue Date: Page 9 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Bridging of functional insulation by a VDR Bridging of basic insulation by a VDR Bridging of supplementary, double or reinforced insulation by a VDR 1.6 Power interface AC power distribution systems Evaluated in power supply approval Input current (see appended table 1.6.2) Voltage limit of hand-held equipment Neutral conductor 1.7 Marking and instructions Power rating The required marking is located on the outside surface of the equipment. Rated voltage(s) or voltage range(s) (V)... : 19Vdc (Optional) Symbol for nature of supply, for d.c. only... : IEC No provided on marking label. (Optional) Rated frequency or rated frequency range (Hz)... : DC Source. Rated current (ma or A)... : 3.42A or 4.74A (Optional) Manufacturer's name or trademark or identification mark... : MICRO-STAR INTERNATIONAL CO., LTD or Model identification or type reference... : MS-16Y1 / Notebook PC Symbol for Class II equipment only... : The equipment is regarded as Class III. Other markings and symbols... : Additional symbols may be provided when submitted for National Approval Safety instructions and marking Safety instructions in English. Other languages will be provided when submitted for national approval General Disconnect devices Class III equipment Overcurrent protective device No such device provided IT Power distribution systems Class III equipment Operator access with a tool

11 Issue Date: Page 10 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Ozone Short duty cycles Equipment is designed for continuous operation Supply voltage adjustment... : Method and means of adjustment; reference to installation instructions... : Power outlets on the equipment... : No standard power outlets are provided Fuse identification (marking, special fusing characteristics, cross-reference)... : Wiring terminals Class III equipment, supplied by SELV Protective earthing and bonding terminals... : Terminal for a.c. mains supply conductors Terminals for d.c. mains supply conductors Controls and indicators Identification, location and marking... : The function of controls affecting safety is obvious regardless of language Colours... : For functional indication a LED lights when the equipment is operating Symbols according to IEC : The stand-by switch is marked with the correct symbol ( IEC-5009) Markings using figures... : Isolation of multiple power sources... : Thermostats and other regulating devices... : Durability All markings provided on UL Recognized Component labels suitable for surface they are applied upon and meet the durability test Removable parts No marking is located on removable parts Replaceable batteries... : Language(s)... : Equipment for restricted access locations... : 2 PROTECTION FROM HAZARDS 2.1 Protection from electric shock and energy hazards

12 Issue Date: Page 11 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Protection in operator access areas See below Access to energized parts The operator cannot access to energized parts. Test by inspection... : The operator has access to bare parts of SELV circuits. Test with test finger (Figure 2A)... : The operator has access to bare parts of SELV circuits. Test with test pin (Figure 2B)... : The operator has access to bare parts of SELV circuits. Test with test probe (Figure 2C)... : No TNV Battery compartments Access to ELV wiring Working voltage (Vpeak or Vrms); minimum distance through insulation (mm)... : Access to hazardous voltage circuit wiring No hazardous voltage present Energy hazards... : Class III unit intended to be supplied by an external adaptor with no energy hazard Manual controls The equipment does not contain any knobs, handles, levers, or the like Discharge of capacitors in equipment Evaluated during separate certification of the power adapter. Measured voltage (V); time-constant (s)... : Energy hazards - d.c. mains supply a) Capacitor connected to the d.c. mains supply.. : b) Internal battery connected to the mains supply : Audio amplifiers... : Protection in service access areas Protection in restricted access locations SELV circuits General requirements Class III unit intended to be supplied by an external nonenergy hazardous SELV power adapter Voltages under normal conditions (V)... : All accessible voltages are less than 42.4 Vp or 60 Vdc and are classified as SELV Voltages under fault conditions (V)... : The unit is supplied by SELV

13 Issue Date: Page 12 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict and all critical fault conditions were considered in power adaptor evaluation Connection of SELV circuits to other circuits... : SELV circuits are only connected to other SELV circuits. 2.3 TNV circuits Limits Type of TNV circuits... : Separation from other circuits and from accessible parts General requirements Protection by basic insulation Protection by earthing Protection by other constructions... : Separation from hazardous voltages Insulation employed... : Connection of TNV circuits to other circuits Insulation employed... : Test for operating voltages generated externally 2.4 Limited current circuits General requirements Limit values Frequency (Hz)... : - Measured current (ma)... : - Measured voltage (V)... : - Measured circuit capacitance (nf or uf)... : Connection of limited current circuits to other circuits 2.5 Limited power sources a) Inherently limited output Connectors are determined data pins only. See Enclosure 7-01 for detail. b) Impedance limited output USB outputs limited by PTC devices.

14 Issue Date: Page 13 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict c) Regulating network limited output under normal operating and single fault condition See Table for PTC specifications. d) Overcurrent protective device limited output Max. output voltage (V), max. output current (A), max. apparent power (VA)... : See Enclosure 7-01 for detail. - Current rating of overcurrent protective device (A) : Provisions for earthing and bonding Protective earthing Class III equipment Functional earthing Protective earthing and protective bonding conductors General Size of protective earthing conductors Rated current (A), cross-sectional area (mm2), AWG... : Size of protective bonding conductors Rated current (A), cross-sectional area mm2), AWG... : Resistance of earthing conductors and their terminations; resistance (ohm), voltage drop (V), test current (A), duration (min)... : Colour of insulation... : Terminals General Protective earthing and bonding terminals Rated current (A), type, nominal thread diameter (mm)... : Separation of the protective earthing conductor from protective bonding conductors Integrity of protective earthing Interconnection of equipment Components in protective earthing conductors and protective bonding conductors Disconnection of protective earth Parts that can be removed by an operator Parts removed during servicing - - -

15 Issue Date: Page 14 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Corrosion resistance Screws for protective bonding Reliance on telecommunication network or cable distribution system 2.7 Overcurrent and earth fault protection in primary circuits Basic requirements Class III equipment. Instructions when protection relies on building installation Faults not covered in Short-circuit backup protection Number and location of protective devices... : Protection by several devices Warning to service personnel... : 2.8 Safety interlocks General principles Protection requirements Inadvertent reactivation Fail-safe operation Moving parts Overriding Switches and relays Contact gaps (mm)... : Overload test Endurance test Electric strength test Mechanical actuators 2.9 Electrical insulation Properties of insulating materials Natural rubber, materials containing asbestos and hygroscopic materials are not used as insulation Humidity conditioning Relative humidity (%), temperature ( XC)... : Grade of insulation Functional insulation.

16 Issue Date: Page 15 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Insulation in power supply is evaluated in power supply approval Separation from hazardous voltages Evaluated in power supply approval. Method(s) used... : Clearances, creepage distances and distances through insulation General Insulation are considered evaluated in power supply approval. For functional insulation see Pollution degree 2 applicable Frequency... : Evaluated during separate certification of the power adapter Pollution degrees... : Pollution Degree Reduced values for functional insulation Intervening unconnected conductive parts Insulation with varying dimensions Special separation requirements Insulation in circuits generating starting pulses Determination of working voltage Evaluated during separate certification of the power adapter General RMS working voltage Peak working voltage Clearances See appended table and and clause General Mains transient voltages a) AC mains supply... : b) Earthed d.c. mains supplies... : c) Unearthed d.c.. mains supplies... : d) Battery operation... : Clearances in primary circuits

17 Issue Date: Page 16 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Clearances in secondary circuits Clearances in circuits having starting pulses Transients from a.c. mains supply... : Transients from d.c. mains supply... : Transients from telecommunication networks and cable distribution systems... : Measurement of transient voltage levels a) Transients from a mains supply For an a.c. mains supply... : For a d.c. mains supply... : b) Transients from a telecommunication network Creepage distances See appended table and and clause General Material group and comparative tracking index CTI tests... : Material group IIIb assumed; - CTI < Minimum creepage distances Solid insulation General Distances through insulation Insulating compound as solid insulation Semiconductor devices Cemented joints Thin sheet material - General Separable thin sheet material Number of layers (pcs)... : Non-separable thin sheet material Thin sheet material - standard test procedure Electric strength test... : Thin sheet material - alternative test procedure Electric strength test... : Insulation in wound components Wire in wound components Working voltage... : a) Basic insulation not under stress... : b) Basic, supplementary, reinforced insulation... :

18 Issue Date: Page 17 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict c) Compliance with Annex U... : Two wires in contact inside wound component; angle between 45 o C and 90 o C... : Wire with solvent-based enamel in wound components Electric strength test... : - Routine test Additional insulation in wound components Evaluated in power supply approval. Working voltage... : - Basic insulation not under stress... : - Supplementary, reinforced insulation... : Construction of printed boards Uncoated printed boards Coated printed boards No coated printed boards Insulation between conductors on the same inner surface of a printed board Insulation between conductors on different layers of a printed board Distance through insulation Number of insulation layers (pcs)... : Component external terminations Tests on coated printed boards and coated components Sample preparation and preliminary inspection No special coating in order reduce distances Thermal conditioning Electric strength test Abrasion resistance test Thermal cycling Test for Pollution Degree 1 environment and insulating compound Tests for semiconductor devices and cemented joints Enclosed and sealed parts 3 WIRING, CONNECTIONS AND SUPPLY 3.1 General

19 Issue Date: Page 18 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Current rating and overcurrent protection Adequate cross sectional areas on internal wiring Protection against mechanical damage Wire ways are smooth and free from edges. Wires are adequately fixed to prevent excessive strain on wire and terminals and avoiding damage to the insulation of the conductor Securing of internal wiring Internal wiring is secured against excessive strain, loosening of terminals and damage to the conductor insulation Insulation of conductors Insulation on internal conductors is considered to be of adequate quality and suitable for the application and the working voltage involved Beads and ceramic insulators No beads or similar ceramic insulators on conductors Screws for electrical contact pressure No electrical contact pressure Insulating materials in electrical connections No contact pressure through insulating material Self-tapping and spaced thread screws Thread-cutting or space thread screws are not used for electrical connections Termination of conductors Terminations cannot become displaced so that clearances and creepage distance can be reduced. 10 N pull test All conductors are reliably secured Sleeving on wiring No sleeving used as supplementary insulation. 3.2 Connection to mains supply Means of connection No direct connection to mains Connection to an a.c. mains supply Connection to a d.c. mains supply Multiple supply connections Permanently connected equipment Number of conductors, diameter of cable and -

20 Issue Date: Page 19 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict conduits (mm)... : Appliance inlets Power supply cords AC power supply cords Type... : - Rated current (A), cross-sectional area (mm2), AWG... : DC power supply cords Cord anchorages and strain relief Mass of equipment (kg), pull (N)... : - Longitudinal displacement (mm)... : Protection against mechanical damage Cord guards Diameter of minor dimension D (mm); test mass (g)... : Radius of curvature of cord (mm)... : Supply wiring space Wiring terminals for connection of external conductors Wiring terminals Connection of non-detachable power supply cords Screw terminals Conductor sizes to be connected Rated current (A), cord/cable type, cross-sectional area (mm2)... : Wiring terminal sizes Rated current (A), type and nominal thread diameter (mm)... : Wiring terminals design Grouping of wiring terminals Stranded wire Disconnection from the mains supply General requirement No direct connection to mains Disconnect devices Permanently connected equipment Parts which remain energized

21 Issue Date: Page 20 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Switches in flexible cords Number of poles - single-phase and d.c. equipment Number of poles - three-phase equipment Switches as disconnect devices Plugs as disconnect devices Interconnected equipment Multiple power sources 3.5 Interconnection of equipment General requirements Interconnection circuit selected to provided conformance to the requirements of 2.2 for SELV CIRCUITS Types of interconnection circuits... : Interconnection circuits are SELV, Limited Current Circuit, TNV-3 circuits ELV circuits as interconnection circuits No ELV interconnections Data ports for additional equipment Data parts only signal. 4 PHYSICAL REQUIREMENTS 4.1 Stability Angle of 10 Test force (N)... : The unit is not floor-standing equipment. 4.2 Mechanical strength General Complies with the requirement also after tests described below are applied Steady force test, 10 N Steady force test, 30 N Steady force test, 250 N No hazards as a result of the 250N test Impact test Fall test Swing test Drop test; height (mm)... : - Transportable equipment. No damage after 1m drop. - There was no possible of

22 Issue Date: Page 21 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict accessing hazardous parts Stress relief test Test is carried out at 70 o C/ 7h, No risk of shrinkage or distortion on enclosures due to release of internal stresses Cathode ray tubes No such device within the equipment. Picture tube separately certified... : High pressure lamps No high pressure lamp Wall or ceiling mounted equipment; force (N)... : 4.3 Design and construction Edges and corners All edges and corners are judged to be sufficiently well rounded so as not to constitute a hazard Handles and manual controls; force (N)... : None that would cause hazard Adjustable controls No such device within the equipment Securing of parts Mechanical connections can be expected to withstand usual mechanical stress Connection by plugs and sockets Direct plug-in equipment Not a direct plug-in unit. Torque... : Compliance with the relevant mains plug standard: Heating elements in earthed equipment No such device within the equipment Batteries Battery Pack are nonapproved component, there is no reverse polarity installation could be happen due to design of socket and mechanical construction in Notebook PC. - The RTC battery protected by D2001 and R2001 for M/B: A15HC. (see appended table 5.3) - Overcharging of a rechargeable battery - Unintentional charging of a non-rechargeable battery

23 Issue Date: Page 22 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict - Reverse charging of a rechargeable battery - Excessive discharging of any battery Oil and grease Dust, powders, liquids and gases Containers for liquids or gases Flammable liquids... : Quantity of liquid (l)... : Flash point ( C)... : Radiation General Ionizing radiation Measured radiation (pa/kg)... : - Measured high-voltage (kv)... : - Measured focus voltage (kv)... : - CRT markings... : Effect of ultraviolet (UV) radiation on materials Part, property, retention after test, flammability classification... : Human exposure to ultraviolet (UV) radiation... : Laser (including LEDs) This product contains only visible indicator LEDs (Class 1) operating in the range of nm wavelength. No IEC evaluation was deemed necessary. Additional review may be required at the discretion of the accepting NCB. Laser class... : This product contains only visible indicator LEDs (Class 1) operating in the range of nm wavelength. No IEC evaluation was deemed necessary. Additional review may be required at the discretion of the accepting NCB Other types... : Protection against hazardous moving parts General Resetting of internal

24 Issue Date: Page 23 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict components during operation does not present a risk of personal injury Protection in operator access areas... : No hazardous moving parts in operator access areas Protection in restricted access locations... : Protection in service access areas Unintentional contact with hazardous moving parts by service personnel is unlikely. 4.5 Thermal requirements General Temperature tests The equipment and its components did not attain excessive temperature during normal operation. (See appended table 4.5) Normal load condition per Annex L... : Operated in the most unfavorable way of operation given in the operating instructions until steady conditions established Temperature limits for materials (See appended table 4.5) Touch temperature limits (See appended table 4.5) Resistance to abnormal heat... : Evaluated during separate certification of the power adapter Openings in enclosures Top and side openings Transportable equipment. Dimensions (mm)... : Bottoms of fire enclosures Transportable equipment. Construction of the bottom, dimensions (mm)... : Doors or covers in fire enclosures Openings in transportable equipment Fire enclosure construction is considered to comply with the requirement. See appended miscellaneous of ID Constructional design measures Openings do not exceed 1 mm in width regardless of length. (fan openings are achieved via

25 Issue Date: Page 24 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict internal heatsink construction) Dimensions (mm)... : Fire enclosure construction is - considered to comply with the requirement. See appended miscellaneous of ID Evaluation measures for larger openings Use of metallized parts Adhesives for constructional purposes Conditioning temperature ( C), time (weeks)... : Resistance to fire Reducing the risk of ignition and spread of flame Method 1 - Selection and application of components, wiring and materials, which reduce the possibility of ignition and spread of flame by the use of fire enclosure. Method 1, selection and application of components wiring and materials Method 2, application of all of simulated fault condition tests Conditions for a fire enclosure See Parts requiring a fire enclosure Fire enclosure covers all parts Parts not requiring a fire enclosure Materials General Components and materials have adequate flammability classification. See appended table Materials for fire enclosures (See appended table 1.5.1) Materials for components and other parts outside fire enclosures Materials for components and other parts inside fire enclosures Decorative parts and parts outside of the fire enclosure are made of minimum HB material. Connectors are made of materials of Class V-2 minimum. Other materials inside fire enclosure are minimum V-2 material Materials for air filter assemblies

26 Issue Date: Page 25 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict Materials used in high-voltage components 5 ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS 5.1 Touch current and protective conductor current General Evaluated as part of power supply investigation Configuration of equipment under test (EUT) Single connection to an a.c. mains supply Redundant multiple connections to an a.c. mains supply Simultaneous multiple connections to an a.c. mains supply Test circuit Application of measuring instrument Test procedure Test measurements Supply voltage (V)... : - Measured touch current (ma)... : - Max. allowed touch current (ma)... : - Measured protective conductor current (ma)... : - Max. allowed protective conductor current (ma)... : Equipment with touch current exceeding 3,5 ma General... : Simultaneous multiple connections to the supply Touch currents to telecommunication networks and cable distribution systems and from telecommunication networks Limitation of the touch current to a telecommunication network or to a cable distribution system No TNV presents. Supply voltage (V)... : - Measured touch current (ma)... : - Max. allowed touch current (ma)... : Summation of touch currents from telecommunication networks a) EUT with earthed telecommunication ports... : b) EUT whose telecommunication ports have no reference to protective earth

27 Issue Date: Page 26 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict 5.2 Electric strength General Test procedure 5.3 Abnormal operating and fault conditions Protection against overload and abnormal operation (See appended table 5.3) Motors Approval DC Fan used Transformers No isolating transformer in the equipment Functional insulation... : Functional insulation complies with requirement (c). Considered due to all components are mounted on PCB of flammability V-1 min Electromechanical components Audio amplifiers in ITE... : Simulation of faults (See appended table 5.3) Unattended equipment Compliance criteria for abnormal operating and fault conditions No fire occurred. No molten metal was emitted During the tests No fire, emission of molten metal or deformation was noted during the tests After the tests 6 CONNECTION TO TELECOMMUNICATION NETWORKS 6.1 Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment Protection from hazardous voltages Separation of the telecommunication network from earth Requirements Supply voltage (V)... : - Current in the test circuit (ma)... : Exclusions... : 6.2 Protection of equipment users from overvoltages on telecommunication

28 Issue Date: Page 27 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict networks Separation requirements Electric strength test procedure Impulse test Steady-state test Compliance criteria 6.3 Protection of the telecommunication wiring system from overheating Max. output current (A)... : - Current limiting method... : - 7 CONNECTION TO CABLE DISTRIBUTION SYSTEMS 7.1 General 7.2 Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment 7.3 Protection of equipment users from overvoltages on the cable distribution system 7.4 Insulation between primary circuits and cable distribution systems General Voltage surge test Impulse test A ANNEX A, TESTS FOR RESISTANCE TO HEAT AND FIRE A.1 Flammability test for fire enclosures of movable equipment having a total mass exceeding 18 kg, and of stationary equipment (see ) A.1.1 Samples... : - Wall thickness (mm)... : - A.1.2 Conditioning of samples; temperature ( o C)... : A.1.3 Mounting of samples... : A.1.4 Test flame (see IEC ) Flame A, B, C or D... : A.1.5 Test procedure A.1.6 Compliance criteria Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : -

29 Issue Date: Page 28 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict A.2 Flammability test for fire enclosures of movable equipment having a total mass not exceeding 18 kg, and for material and components located inside fire enclosures (see and ) A.2.1 Samples, material... : - Wall thickness (mm)... : - A.2.2 Conditioning of samples; temperature ( C)... : A.2.3 Mounting of samples... : A.2.4 Test flame (see IEC ) Flame A, B or C... : - A.2.5 Test procedure A.2.6 Compliance criteria Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : - A.2.7 Alternative test acc. to IEC , cl. 5 and 9 Sample 1 burning time (s)... : - Sample 2 burning time (s)... : - Sample 3 burning time (s)... : - A.3 Hot flaming oil test (see 4.6.2) A.3.1 Mounting of samples A.3.2 Test procedure A.3.3 Compliance criterion B ANNEX B, MOTOR TESTS UNDER ABNORMAL CONDITIONS(see and 5.3.2) B.1 General requirements Position... : - Manufacturer... : - Type... : - Rated values... : - B.2 Test conditions B.3 Maximum temperatures B.4 Running overload test B.5 Locked-rotor overload test Test duration (days)... : - Electric strength test: test voltage (V)... : - B.6 Running overload test for d.c. motors in secondary

30 Issue Date: Page 29 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict circuits B.6.1 General B.6.2 Test procedure B.6.3 Alternative test procedure B.6.4 Electric strength test; test voltage (V)... : B.7 Locked-rotor overload test for d.c. motors in secondary circuits B.7.1 General B.7.2 Test procedure. B.7.3 Alternative test procedure B.7.4 Electric strength test; test voltage (V)... : B.8 Test for motors with capacitors B.9 Test for three-phase motors B.10 Test for series motors Operating voltage (V)... : - C ANNEX C, TRANSFORMERS (see and 5.3.3) Position... : - Manufacturer... : - Type... : - Rated values... : - Method of protection... : - C.1 Overload test C.2 Insulation Protection from displacement of windings... : D ANNEX D, MEASURING INSTRUMENTS FOR TOUCH-CURRENT TESTS (see 5.1.4) D.1 Measuring instrument D.2 Alternative measuring instrument E ANNEX E, TEMPERATURE RISE OF A WINDING (see ) F ANNEX F, MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES (see 2.10 and Annex G) G ANNEX G, ALTERNATIVE METHOD FOR DETERMINING MINIMUM CLEARANCES

31 Issue Date: Page 30 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict G.1 Clearances G.1.1 General G.1.2 Summary of the procedure for determining minimum clearances G.2 Determination of mains transient voltage (V) G.2.1 AC mains supply... : G.2.2 Earthed d.c. mains supply... : G.2.3 Unearthed d.c. mains supply... : G.2.4 Battery operation... : G.3 Determination of telecommunication network transient voltage (V) :... : G.4 Determination of required withstand voltage (V) G.4.1 Mains transients and internal repetitive peaks... : G.4.2 Transients from telecommunication networks... : G.4.3 Combination of transients G.4.4 Transients from cable distribution systems G.5 Measurement of transient voltages (V) G.6 Determination of minimum clearances... : H ANNEX H, IONIZING RADIATION (see ) J ANNEX J, TABLE OF ELECTROCHEMICAL POTENTIALS (see ) Metal(s) used... : - K ANNEX K, THERMAL CONTROLS (see and 5.3.8) K.1 Making and breaking capacity K.2 Thermostat reliability; operating voltage (V)... : K.3 Thermostat endurance test; operating voltage (V) : K.4 Temperature limiter endurance; operating voltage (V)... : K.5 Thermal cut-out reliability K.6 Stability of operation L ANNEX L, NORMAL LOAD CONDITIONS FOR SOME TYPES OF ELECTRICAL BUSINESS EQUIPMENT (see and 4.5.2) L.1 Typewriters L.2 Adding machines and cash registers

32 Issue Date: Page 31 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict L.3 Erasers L.4 Pencil sharpeners L.5 Duplicators and copy machines L.6 Motor-operated files L.7 Other business equipment See table M ANNEX M, CRITERIA FOR TELEPHONE RINGING SIGNALS (see 2.3.1) M.1 Introduction M.2 Method A M.3 Method B M.3.1 Ringing signal M Frequency (Hz)... : - M Voltage (V)... : - M Cadence; time (s), voltage (V)... : - M Single fault current (ma)... : - M.3.2 Tripping device and monitoring voltage... : M Conditions for use of a tripping device or a monitoring voltage M Tripping device M Monitoring voltage (V)... : N ANNEX N, IMPULSE TEST GENERATORS (see , , , , 7.3.2, and Clause G.5) N.1 ITU-T impulse test generators N.2 IEC impulse test generator P ANNEX P, NORMATIVE REFERENCES Q ANNEX Q, Voltage dependent resistors (VDRs) (see ) a) Preferred climatic categories... : b) Maximum continuous voltage... : c) Pulse current... : R ANNEX R, EXAMPLES OF REQUIREMENTS FOR QUALITY CONTROL

33 Issue Date: Page 32 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict PROGRAMMES R.1 Minimum separation distances for unpopulated coated printed boards (see ) R.2 Reduced clearances (see ) S ANNEX S, PROCEDURE FOR IMPULSE TESTING (see ) S.1 Test equipment S.2 Test procedure S.3 Examples of waveforms during impulse testing T ANNEX T, GUIDANCE ON PROTECTION AGAINST INGRESS OF WATER (see 1.1.2)... : - U ANNEX U, INSULATED WINDING WIRES FOR USE WITHOUT INTERLEAVED INSULATION (see )... : - V ANNEX V, AC POWER DISTRIBUTION SYSTEMS (see 1.6.1) V.1 Introduction V.2 TN power distribution systems W ANNEX W, SUMMATION OF TOUCH CURRENTS W.1 Touch current from electronic circuits W.1.1 Floating circuits W.1.2 Earthed circuits W.2 Interconnection of several equipments W.2.1 Isolation W.2.2 Common return, isolated from earth W.2.3 Common return, connected to protective earth X ANNEX X, MAXIMUM HEATING EFFECT IN TRANSFORMER TESTS (see clause C.1) X.1 Determination of maximum input current

34 Issue Date: Page 33 of 50 Report Reference # ASL IEC / EN Clause Requirement - Test Result Remark Verdict X.2 Overload test procedure Y ANNEX Y, ULTRAVIOLET LIGHT CONDITIONING TEST (see ) Y.1 Test apparatus... : Y.2 Mounting of test samples... : Y.3 Carbon-arc light-exposure apparatus... : Y.4 Xenon-arc light-exposure apparatus... : Z ANNEX Z, OVERVOLTAGE CATEGORIES (see and Clause G.2) AA ANNEX AA, MANDREL TEST (see )

35 Issue Date: Page 34 of 50 Report Reference # ASL TABLE: list of critical components object/part No. Enclosure (LCD top cover) Enclosure ( for LCD front bezel) Enclosure ( for top side keyboard around) Enclosure ( for top side keyboard around) manufacturer/ trademark Sabic Innovative Plastics Japan LLC Sabic Innovative Plastics Japan LLC Sabic Innovative Plastics Japan LLC Sabic Innovative Plastics Japan LLC type/model technical data standard mark(s) of conformity 1 ) C7230P(X) CM6140(X) C6600(GG)(X)(V S) C6600(GG)(X)(V S) V-0, thickness 1.2 mm min. 85 o C V-1, thickness 0.6 mm min. 60 o C V-1, thickness 1.2 mm min. 60 o C V-1, thickness 1.2 mm min. 60 o C LCD Panel Various Various 15.6 inch (LED Backlight) Power Adapter Delta Electronics ADP-90CD DB Inc. /(trademark for ASUS) Delta Electronics Inc. /(trademark for ASUS) Lite-On Technology Corp. /(trademark for ASUS) FSP Group Inc. Delta Electronics Inc/ (trademark for ASUS) Delta Electronics Inc/ (trademark for ASUS) Delta Electronics Inc ADP-90CD CB PA (The dots. in model name may be 0-9, A-Z, - or blank for marketing purpose only.) FSP090- DVCA1XX (X= 0-9, A-Z or blank for marketing purpose only) ADP-65JH BB ADP-65JH AB ADP-65JH CB I/P: Vac, 50-60Hz, 1.5A O/P: 19Vdc, 4.74A (Class I) 40 C I/P: Vac, 50-60Hz, 1.5A O/P: 19Vdc, 4.74A (Class II) 40 C I/P: Vac, 50-60Hz, 1.5A O/P: 19Vdc, 4.74A (Class I) 40 C I/P: Vac, 50-60Hz, 1.5A O/P: 19Vdc, 4.74A (Class II) 40 C I/P: Vac, 1.5A, 50-60Hz; O/P:19Vdc, 3.42A, (Class I), (LPS), 40 C I/P: Vac, 1.5A, 50-60Hz; O/P:19Vdc, 3.42A, (Class II), (LPS), 40 C I/P: Vac, 1.5A, 50-60Hz; O/P:19Vdc, UL 94 UL 94 UL 94 UL 94 UL UL UL UL -- Tested in the equip. UL nd, UL, CB by IEC : TUV/Rh 2005 (Certificate no. EN JPTUV ) 1:2006 UL nd, IEC : 2005 EN :2006 UL nd, IEC : 2005 EN :2006 IEC : 2005+A1 UL nd, IEC : 2005 EN :2006 UL nd, IEC : 2005 EN :2006 UL nd, IEC : 2005 CB by TUV/RH (Certificate no. JPTUV ) UL, CB by Nemko (Certificate no. NO51279) CB by TUV/RH (Certificate no. JPTUV ) UL, CB by TUV/Rh (Certificate no. JPTUV M1) UL, CB by TUV/Rh (Certificate no. JPTUV ) UL, CB by TUV/Rh (Certificate no.

36 Issue Date: Page 35 of 50 Report Reference # ASL HDD (optional) Optical Drive Device (optional) Speaker (Two provided) Accessory, Rechargeable Li-ion Battery (3S2P) -Battery Cell (3S2P) - Top/Bottom Enclosure for battery pack -Glue (for Top/Bottom Enclosure) -Fuse (F1) Lite-On Technology Corp. /(trademark for ASUS) FSP Group Inc. Seagate Technology, Inc (or equivalent) Hitachi-LG Data Storage, Inc (or equivalent) PA XX (The X can be A- Z, 0-9, hyphen or blank) FSP065-ASCXX (the suffix XX may be 0-9, A-Z or blank) ST9 (or equivalent) GCC- 4244N******* (where * can be any alphanumeric character, symbol, blank indicating different marketing area or band name) (or equivalent) 5Vdc, 2.8A max. Laser Class 1 product Various Various Minimum HB, Each rated, 4 ohm, 2.5 Watts max. Pegatron Corp. A32-A Vdc, 4400 mah or 47 Wh Samsung SDI Co Ltd Sabic Innovative Plastics Japan L L C Taiwan Cemedine co., Ltd. Sony Chemicals Corp. ICR (++=These cells may have an optional single alphanumeric suffix.) BPL1000(C) LN-2250 SFH-1212# (# represents suffix of alphabetical letter used for internal traceability) 3.6Vdc, 2200mAh (lithium type ) V-1 or better, min thick 0.7 mm, 80 o C Max. Temp Rating 60 o C. UL/EN/IEC , EN /IEC A, (Class II), (LPS), 40 C EN :2006 I/P: Vac, IEC : 50-60Hz, 2.0A 2005 O/P: 19Vdc, EN A (Class I), 1:2006+A11:200 (LPS), 40 C 9 I/P: Vac, IEC : 50-60Hz, 2.0A 2005 O/P: 19Vdc, EN A (Class II), 1:2006+A11:200 (LPS), 35 C 9 5Vdc, 1.5A max. UL/EN/IEC JPTUV M2) CB by TUV/RH (Certificate no. JPTUV ) CB by VDE (Certificate no. DE ) UL, TUV, VDE, Nemko UL, TUV, VDE, Nemko -- Tested in the equip. -- Tested in the equip. UL1642 UL94, UL 746C UL 746C 12A, 36Vdc UL 248-1, UL , EN , EN UL UL UL UL, TUV/Rh (Certificate no.: J ) -Thermistor Various Various 10K ohm 25 o C -- Tested in the

37 Issue Date: Page 36 of 50 Report Reference # ASL (TH1) equip. -Mosfet (Q1, Q2) Infineon Technologies BSC884N03MS G Protection IC Texas bq20z (U1) Instruments -PCB Various Various V-1 min., min. UL796 UL 130 o C Accessory, Rechargeable Li-ion Battery (4S2P) Pegatron Corp. A42-A Vdc, 4400 mah, 63 Wh or 14.6 Vdc, 52mAh, 75Wh -- Tested in the equip. -Battery Cell (4S2P) -Battery Cell (4S2P) - Top/Bottom Enclosure for battery pack -Glue (for Top/Bottom Enclosure) -Fuse (F1) Samsung SDI Co Ltd ICR (++=These cells may have an optional single alphanumeric suffix.) LG Chemical Ltd ICR18650B3 Sabic Innovative Plastics Japan L L C Taiwan Cemedine co., Ltd. Sony Chemicals Corp. BPL1000(C) LN-2250 SFH-1412# (# represents suffix of alphabetical letter used for internal traceability) 3.6Vdc, 2200mAh (lithium type ) 3.65Vdc, 2600mAh (lithium type ) V-1 or better, min thick 0.7 mm, 80 o C Max. Temp Rating 60 o C. UL1642 UL1642 UL94, UL 746C UL 746C 12A, 36Vdc UL 248-1, UL , EN , EN UL UL UL UL UL, TUV/Rh (Certificate no.: J ) -Thermistor (TH1) Various Various 10K ohm 25 o C -- Tested in the equip. -Mosfet (Q1, Q2) Infineon Technologies BSC884N03MS G Protection IC Texas bq20z (U1) Instruments -PCB Various Various V-1 min., min. 105 o C UL796 UL DC Fan (for Delta Electronics KSB06105HB 5Vdc, 0.40A UL507, EN UL, VDE CPU) Inc. max., 6.66 CFM : 2006 (Certificate no.: min. Mother Board Pegatron Corp. A15HC See below for detail - RTC Battery CR2032 (Lithium type) Vic-Dawn Enterprise Co., Ltd. / KTS Shun Wo New Power Battery Technology Ltd. / NewSun CR2032 3Vdc, max. abnormal charging current 10mA 3Vdc, max. abnormal charging current 10mA ) -- Tested in the equip. UL 1642 UL UL 1642 Jhih Hong CR2032 3Vdc, maximum UL 1642 UL UL

38 Issue Date: Page 37 of 50 Report Reference # ASL Power Distribution Switch for USB 3.0 port (U5201, U5202) use (Optional when F5201, F5203 provide) - Polyswitch for USB port (F5201, F5203) use - Polyswitch for HDMI port (F5201, F5203) use Technology Co Ltd abnormal charging current 10 ma Various CR2032 3Vdc, maximum abnormal charging current 5mA min., user replaceable against charging current by multiple components D2001 and R2001 rated 1 Kohm. Global Mixedmode Technology Inc. Tyco Electronics Corp Raychem Circuit Protection Division Shanghai Wayon Thermo-Electro Material Co., Ltd. G547 minismdc160xx xxxxxxxxxxxxxxx xxx (x= 0-9, A-Z,., -, blank) LP-NSM035abc (a=f or blank; b= C, U or blank; c= S, Z or blank) UL 1642 UL Vdc, 1.1A IEC/EN CB by TUV/Rh (Certificate no.: JPTUV ) 9Vdc, 1.6A EN UL, TUV (Certificate no.: R ) 6Vdc, 0.35A UL1434, EN , EN UL, TUV (Certificate No: R ) - PCB Various Various V-1 min. 105 o C UL796 UL IO Board Pegatron Corp. A15HC IO BOARD See below for detail -- Tested in the equip. - Polyswitch for USB port (F6901) use Polytronics Technology Corp. SMD1206P150T FT 8Vdc, 1.5A UL 1434 /EN /EN TUV/Rh (Certificate no. R ) - PCB Various Various V-1 min. 105 o C UL796 UL 1 ) an asterisk indicates a mark which assures the agreed level of surveillance

39 Issue Date: Page 38 of 50 Report Reference # ASL TABLE: electrical data (in normal conditions) U (V) I (A) I rated (A) P (W) Fuse # I fuse (A) condition/status MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A42- A15 (14.6Vdc, 5200mAh, 75Wh), Maximum charge current: 3.5A, Maximum discharge current: 5.2A, With VGA Chip, 2 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 15.16Vdc System off with empty battery pack charging mode (Measure battery pack connector) 15.85Vdc Maximum normal load supplied by battery pack discharge mode (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A42- A15 (14.4Vdc, 4400mAh, 63Wh), Maximum charge current: 3.01A, Maximum discharge current: 5.2A, With VGA Chip, 2 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 14.25Vdc System off with empty battery pack charging mode (Measure battery pack connector) 15.80Vdc Maximum normal load supplied by battery pack discharge mode (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A32- A15 (10.8Vdc, 4400mAh, 47Wh), Maximum charge current: 3.01A, Maximum discharge current: 5.2A, With VGA Chip, 2 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 10.96Vdc System off with empty battery pack charging mode (Measure battery pack connector) 11.40Vdc Maximum normal load supplied by

40 Issue Date: Page 39 of 50 Report Reference # ASL battery pack discharge mode (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A42- A15 (14.6Vdc, 5200mAh, 75Wh), Maximum charge current: 3.5A, Maximum discharge current: 5.2A, Without VGA Chip, 4 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 14.93Vdc System off with empty battery pack charging mode (Measure battery pack connector) 15.94Vdc Maximum normal load supplied by battery pack discharge mode (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A42- A15 (14.4Vdc, 4400mAh, 63Wh), Maximum charge current: 3.01A, Maximum discharge current: 5.2A, Without VGA Chip, 4 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 14.19Vdc System off with empty battery pack charging mode (Measure battery pack connector) 15.53Vdc Maximum normal load supplied by battery pack discharge mode (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A32- A15 (10.8Vdc, 4400mAh, 47Wh), Maximum charge current: 3.01A, Maximum discharge current: 5.2A, Without VGA Chip, 4 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 10.85Vdc System off with empty battery pack charging mode (Measure battery pack connector) 11.49Vdc Maximum normal load supplied by battery pack discharge mode

41 Issue Date: Page 40 of 50 Report Reference # ASL (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A42- A15 (14.6Vdc, 5200mAh, 75Wh), Maximum charge current: 3.5A, Maximum discharge current: 5.2A, Without VGA Chip, 2 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 15.15Vdc System off with empty battery pack charging mode (Measure battery pack connector) 16.06Vdc Maximum normal load supplied by battery pack discharge mode (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A42- A15 (14.4Vdc, 4400mAh, 63Wh), Maximum charge current: 3.01A, Maximum discharge current: 5.2A, Without VGA Chip, 2 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 14.24Vdc System off with empty battery pack charging mode (Measure battery pack connector) 15.74Vdc Maximum normal load supplied by battery pack discharge mode (Measure battery pack connector) MB: PEGATRON /A15HC, Supplied by DC power source, Battery Pack: PEGATRON /A32- A15 (10.8Vdc, 4400mAh, 47Wh), Maximum charge current: 3.01A, Maximum discharge current: 5.2A, Without VGA Chip, 2 core CPU 19Vdc Maximum normal load with empty battery pack 19Vdc System off with empty battery pack charging mode 10.94Vdc System off with empty battery pack charging mode (Measure battery pack connector) 11.62Vdc Maximum normal load supplied by battery pack discharge mode (Measure battery pack connector)

42 Issue Date: Page 41 of 50 Report Reference # ASL supplementary information: Maximum normal load: The unit reads and writes in HDD and operating continuously. Each USB2.0 port is loaded with 2.5W and USB3.0 port is loaded with 4.5W. Run CPU program until performance to 100%. LED backlight with max. Brightness, max. Volume of speaker, battery pack is empty and TABLE: clearance and creepage distance measurements Clearance (cl) and creepage distance (cr) at/of/between: U peak (V) U r.m.s. (V) Required cl (mm) cl (mm) Required cr (mm) supplementary information: Functional Insulation, see clause cr (mm) TABLE: distance through insulation measurements Distance through insulation (DTI) at/of: U peak (V) Urms (V) Test voltage (V) Required DTI (mm) DTI (mm) supplementary information: TABLE: Batteries The tests of are applicable only when appropriate battery data is not available Is it possible to install the battery in a reverse polarity position No -- Battery Pack: PEGATRO N /A32- A15 (10.8Vdc, 4400mAh, 47Wh) Max. current Rapid dischargin g [Q1 (1-8) Non-rechargeable batteries Discharging Meas. current Manuf. specs. Unintentional charging Meas. current Rechargeable batteries Charging Discharging Reversed charging Manuf. specs. Meas. current Manuf. specs. Meas. current Manuf. specs A 5.2A -- --

43 Issue Date: Page 42 of 50 Report Reference # ASL short] Battery Pack: PEGATRO N /A42- A15 (14.6Vdc, 5200mAh, 75Wh, Cell: LG CHEMICA L LTD /ICR18650 B3) Max. current during normal condition Max. current during fault condition Battery Pack: PEGATRO N /A42- A15 (14.4Vdc, 4400mAh, 63Wh, Cell: SAMSUN G SDI CO LTD /ICR F) Max. current during normal condition Max. current during fault condition Battery Pack: PEGATRO N /A32- A15 (10.8Vdc, 4400mAh, 47Wh, A A C.C. mode, 3.5 A Q2 (1-8) short / C.C. mode, 3.5 A 5.2 A 5.2 A A Q1 (1-8) short / 5.2 A A A C.C. mode, 3.01 A Q2 (1-8) short / C.C. mode, 3.01 A 5.2 A 5.2 A A Q1(1-8) short / 5.2 A

44 Issue Date: Page 43 of 50 Report Reference # ASL Cell: SAMSUN G SDI CO LTD /ICR F) Max. current during normal condition Max. current during fault condition A A C.C. mode, 3.01 A Q2 (1-8) short / C.C. mode, 3.01 A 5.2 A 5.2 A A Q1 (1-8) short / 5.2 A Test results: -- Verdict - Chemical leaks No such result occurred - Explosion of the battery No such result occurred - Emission of flame or expulsion of molten metal No such result occurred - Electric strength tests of equipment after completion of tests -- supplementary information: For RTC battery and without battery charging circuit. About the detail for the fault conditions and result, please see appended table TABLE: Thermal requirements Supply voltage (V)... : see below see below see below see below -- Ambient Tmin ( o C)... : Ambient Tmax ( o C)... : see below see below see below see below -- Maximum measured temperature T of part/at: T ( o C) allowed Tmax ( o C) Normal Condition MB: PEGATRON /A15HC, Adapter: Delta /ADP- 90CD DB, Battery Pack: PEGATRON/ A42-A15 (14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta Electronics Inc /KSB06105HB, With VGA Chip, 2 core CPU Conditi on 1 (Origin al) Conditi on 1 (Shift to 35) Conditi on 2 (Origin al) Conditi on 2 (Shift to 35) Ambient PWB near CPU PWB near North Bridge Chip RTC battery body Enclosure inside near CPU Enclosure outside near CPU Enclosure near battery connector

45 Issue Date: Page 44 of 50 Report Reference # ASL Battery Pack body PTC body (F6901) PWB near VGA Chip Normal Condition MB: PEGATRON /A15HC, Adapter: Delta /ADP- 90CD DB, Battery Pack: PEGATRON/ A42-A15 (14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta Electronics Inc /KSB06105HB, Without VGA Chip, 4 core CPU Conditi on 3 (Origin al) Conditi on 3 (Shift to 35) Conditi on 4 (Origin al) Conditi on 4 (Shift to 35) Ambient PWB near CPU PWB near North Bridge Chip RTC battery body Enclosure inside near CPU Enclosure outside near CPU Enclosure near battery connector Battery Pack body PTC body (F6901) Normal Condition Battery pack discharge mode 6.02A, Battery Pack Model: A32-A15 (10.8Vdc, 4400mAh, 47Wh) Conditi on 5 (Origin al) Conditi on 5 (Shift to 35) Ambient Cell body PWB near Q PWB near R Enclosure inside near Q Enclosure outside near Q Enclosure inside near R Enclosure outside near R Normal Condition Battery Pack: PEGATRON/ A42-A15 (14.6Vdc, 5200mAh, 75Wh, Cell: LG CHEMICAL LTD /ICR18650B3), Maximum charging voltage: 17.0Vdc, Maximum charging current: 3.5A, Maximum discharging current: 5.2A Conditi on 6 (Origin al) Conditi on 6 (Shift to 35) Conditi on 7 (Origin al) Conditi on 7 (Shift to 35) Ambient Enclosure outside near Q1,Q Enclosure inside near Q1,Q Cell body PWB near Q1,Q Normal Condition Battery Pack: PEGATRON/ A42-A15 (14.4Vdc, 4400mAh, 63Wh, Cell: SAMSUNG SDI CO LTD /ICR F), Maximum charging voltage: 17.0Vdc, Maximum charging current: 3.01A, Maximum discharging current: 5.2A Conditi on 8 (Origin al) Conditi on 8 (Shift to 35) Conditi on 9 (Origin al) Conditi on 9 (Shift to 35) Ambient Enclosure outside near Q1,Q Enclosure inside near Q1,Q Cell body PWB near Q1,Q Normal Condition Battery Pack: PEGATRON/ A32-A15 (14.4Vdc, 4400mAh, 63Wh, Cell: SAMSUNG SDI CO LTD Conditi on 10 (Origin Conditi on 10 (Shift Conditi on 11 (Origin Conditi on 11 (Shift -- --

46 Issue Date: Page 45 of 50 Report Reference # ASL /ICR F), Maximum charging voltage: al) to 35) al) to 35) 17.0Vdc, Maximum charging current: 3.01A, Maximum discharging current: 5.2A 1.Ambient Enclosure outside near Q1,Q Enclosure inside near Q1,Q Cell body PWB near Q1,Q temperature T of winding: t 1 ( o C) R 1 ( ) t 2 ( o C) R 2 ( ) T ( o C) allowed T max ( o C) supplementary information: insulation class MB: PEGATRON /A15HC, Adapter: Delta /ADP-90CD DB, Battery Pack: PEGATRON /A42-A15 (14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta Electronics Inc /KSB06105HB, With VGA Chip, 2 core CPU Test Condition 1: Maximum normal load 19Vdc with empty battery pack, Duration 2hrs.56mins. Test Condition 2: Maximum normal load with full battery pack discharge mode, Duration 2hrs.4mins. MB: PEGATRON /A15HC, Adapter: Delta /ADP-90CD DB, Battery Pack: PEGATRON /A42-A15 (14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta Electronics Inc /KSB06105HB, Without VGA Chip, 4 core CPU Test Condition 3: Maximum normal load 19Vdc with empty battery pack, Duration 2hrs.21mins. Test Condition 4: Maximum normal load with full battery pack discharge mode, Duration 1hrs.57mins. Battery pack discharge mode 6.02A, Battery Pack Model: A32-A15 (10.8Vdc, 4400mAh, 47Wh) Test Condition 5: Battery pack discharge mode 6.02A, Duration 1hrs.25mins. Battery Pack: PEGATRON /A42-A15 (14.6Vdc, 5200mAh, 75Wh, Cell: LG CHEMICAL LTD /ICR18650B3), Maximum charging voltage: 17.0Vdc, Maximum charging current: 3.5A, Maximum discharging current: 5.2A Test Condition 6: Charging Test, Duration 2hrs.21mins. Test Condition 7: Discharging test, Duration 1hrs.50mins. Battery Pack: PEGATRON /A42-A15 (14.4Vdc, 4400mAh, 63Wh, Cell: SAMSUNG SDI CO LTD /ICR F), Maximum charging voltage: 17.0Vdc, Maximum charging current: 3.01A, Maximum discharging current: 5.2A Test Condition 8: Charging Test, Duration 2hrs.25mins. Test Condition 9: Discharging test, Duration 1hrs.51mins. Battery Pack: PEGATRON /A32-A15 (10.8Vdc, 4400mAh, 47Wh, Cell: SAMSUNG SDI CO LTD /ICR F), Maximum charging voltage: 12.75Vdc, Maximum charging current: 3.01A, Maximum discharging current: 5.2A Test Condition 10: Charging Test, Duration 2hrs.13mins. Test Condition 11: Discharging test, Duration 1hrs.48mins. The temperatures were measured under worst case normal mode defined in and described in at voltages as described in Without specified ambient temperature in users manual, therefore the ambient temperature assumed as 35 degree C, the max. allowed temperature is listed as follows: Components with: Max.temp.of 105 C (PWB) Max.temp.of 100 C (RTC,Cell) Max.temp.of 85 C (PTC)

47 Issue Date: Page 46 of 50 Report Reference # ASL Max.temp.of 60 C (Enclosure for Notebook) Max.temp.of 80 C (Enclosure for Battery Pack) User accessible area: Material is plastic 75 C TABLE: Ball pressure test of thermoplastic parts allowed allowed impression diameter (mm)... : part test temperature ( C) impression diameter (mm) supplementary information: 4.7 TABLE: resistance to fire part manufacturer of material type of material thickness (mm) flammability class Evidence supplementary information: See table for detail. 5.2 TABLE: electric strength tests, impulse tests and voltage surge tests Test voltage applied between: Voltage shape (AC, DC, impulse, surge) Test voltage (V) Breakdown Yes / No supplementary information: TABLE: fault condition tests ambient temperature ( C)... : See below Power source for EUT: Manufacturer, model/type, output rating... : see appended table Component No. Fault Supply voltage (V) Test time Fuse # Fuse current (A) Observation BATTERY TESTS Battery Pack: PEGATRON/ A32-A15 (10.8Vdc, 4400mAh, 47Wh) Rapid Short 12.75Vdc 7hrs Max. Discharging

48 Issue Date: Page 47 of 50 Report Reference # ASL discharge Q1 (1-8) 0mins. voltage=12.75vdc, Max. Discharging current=6.02a, No damage, No hazards, F1 open, Cell body=49.0 degree C, PWB near Q1=75.5 degree C, Ambient=25.8 degree C Battery Pack: PEGATRON/ A42-A15 (14.6Vdc, 5200mAh, 75Wh, Cell: LG CHEMICAL LTD /ICR18650B3) None (overcharg e test) Q2 1-8 (overcharg e test) Q1 1-8 (discharge test) Battery Pack Output Vdc 8hrs. 08mins. short 24Vdc 8hrs. 08mins. short 17.0Vdc 19hrs. 04mins. short 17.0Vdc 19hrs. 04mins Test by C.C. mode(3.5a), No damage, No hazards, Ambient=21.3 degree C, Cell body = 21.7 degree C, PWB near Q1,Q2 = 21.7 degree C Test by C.C. mode(3.5a), F1 open, No hazards, Ambient=21.3 degree C, Cell body=23.0 degree C, PWB near Q1,Q2=26.0 degree C Discharge current 5.2A, F1 open, No hazards, Ambient=20.8 degree C, Cell body=66.0 degree C, PWB near Q1,Q2=98.0 degree C No damage, No hazards, Ambient=20.8 degree C, Cell body=20.9 degree C, PWB near Q1,Q2=21.0 degree C Battery Pack: PEGATRON/ A42-A15 (14.4Vdc, 4400mAh, 63Wh, Cell: SAMSUNG SDI CO LTD/ ICR F) None (overcharg e test) Q2 1-8 (overcharg e test) Q1 1-8 (discharge -- 24Vdc 8hrs. 07mins. short 24Vdc 8hrs. 07mins. short 17.0Vdc 7hrs. 34mins Test by C.C. mode(3.01a), No damage, No hazards, Ambient=22.3 degree C, Cell body=22.5 degree C, PWB near Q1,Q2=22.6 degree C Test by C.C. mode(3.01a), F1 open, No hazards, Ambient=22.3 degree C, Cell body=23.7 degree C, PWB near Q1,Q2=26.9 degree C Discharge current 5.2A, F1 open, No hazards,

49 Issue Date: Page 48 of 50 Report Reference # ASL test) Ambient=22.5 degree C, Cell body=48.0 degree C, PWB near Q1,Q2=59.0 degree C. Battery Pack Output + - short 17.0Vdc 7hrs. 34mins No damage, No hazards, Ambient=22.5 degree C, Cell body=22.6 degree C, PWB near Q1,Q2=22.7 degree C Battery Pack: PEGATRON/ A32-A15 (10.8Vdc, 4400mAh, 47Wh, Cell: SAMSUNG SDI CO LTD/ ICR F) None (overcharg e test) Q2 S-D (overcharg e test) Q1 S-D (discharge test) Battery Pack Output Vdc 8hrs. 15mins. short 18.0Vdc 8hrs. 15mins. short 12.75Vdc 7hrs. 15mins short 12.75Vdc 7hrs. 15mins Test by C.C mode(3.01 A), No damage, No hazards, Ambient=22.1 degree C, Cell body=22.2 degree C, PWB near Q1,Q2=22.2 degree C Test by C.C mode(3.01 A), F1 open, No hazards, Ambient=22.1 degree C, Cell body=22.9 degree C, PWB near Q1,Q2=25.4 degree C Discharge current=5.2a, F1 open, No hazards, Ambient=21.9 degree C, Cell body=48.0 degree C, PWB near Q1,Q2=56.0 degree C No damage, No hazards, Ambient=21.9 degree C, Cell body=22.0 degree C, PWB near Q1,Q2=22.1 degree C LITHIUM BATTERY REVERSE CURRENT MEASUREMENT TEST MB: PEGATRO15HC RTC battery reverse current test RTC battery reverse current test R2001 RTC battery reverse Normal 19Vdc Charging current is 0.1mA Short 19Vdc Charging current is 0.1mA Short 19Vdc Charging current is 3.4mA

50 Issue Date: Page 49 of 50 Report Reference # ASL current test D2001 (1-2) RTC battery reverse current test D2001 (2-3) RTC battery (C2003) for Vic-Dawn Enterprise Co., Ltd. / KTS /type: CR2032 RTC battery (C2003) for Shun Wo New Power Battery Technolog y Ltd. / NewSun /type: CR2032 RTC battery (C2003) for Jhih Hong Technolog y Co Ltd /type: CR2032 Short 19Vdc Charging current is 3.0mA Short 3Vdc 7hrs Maximum Discharge Current 2.88mA, No hazardous. Short 3Vdc 7hrs Maximum Discharge Current 2.88mA, No hazardous. Short 3Vdc 7hrs Maximum Discharge Current 2.88mA, No hazardous ABNORMAL OPERATION TESTS MB: PEGATRON /A15HC, Adapter: Delta /ADP- 90CD DB, Battery Pack: PEGATRON/ A42-A15 (14.6Vdc, 5200mAh, 75Wh), CPU fan: Delta Electronics Inc /KSB06105HB, With VGA Chip, 2 core CPU 1.CPU fan Stalled 19Vdc 2hrs.43min s. 2.Ventilatio n openings Blocked 19Vdc 1hrs.55min s NT.NC.CT. Normal operation. No hazardous. Maximum Temp: PWB near North Bridge Chip=75.2 degree C, Ambient=26.6 degree C NT.NC. Unit shutdown. No hazardous. Maximum

51 Issue Date: Page 50 of 50 Report Reference # ASL Temp: PWB near North Bridge Chip=76.5 degree C, Ambient=25.0 degree C. supplementary information: Comments Key: (COMPONENT FAILURE TEST; ABNORMAL OPERATION TEST; TRANSFORMER ABNORMAL OPERATION TEST) IP - Internal protection operated (list component), CT - Constant temperatures were obtained, CD - Components damaged (list damaged components), NB - No indication of dielectric breakdown, NT - Tissue paper remained intact, NC - Cheesecloth remained intact, (OVERLOAD OF OPERATOR ACCESSIBLE CONNECTOR TEST) C - Circuit measures less than 12.5mA, B - Circuit measures 0 Volts

52 Issue Date: Page 1 of 21 Report Reference # ASL Enclosure National Differences Australia* Austria** Belgium** Czech Republic** Denmark Finland France** Germany Greece** Group Hungary** Ireland Italy** Japan* Korea Netherlands** Norway Poland** Portugal** Slovakia** Slovenia** Spain Sweden Switzerland USA / Canada United Kingdom * No National Differences Declared ** Only Group Differences

53 Issue Date: Page 2 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict Denmark - Differences to IEC :2005, Second Edition Certain types of Class I appliances (see sub-clause ) may be provided with plug not establishing earthing continuity when inserted into Danish socket-outlets Supply cords of Class I equipment, which is delivered without a plug, must be provided with a visible tag with the following text: "Vigtigt! Lederen med gron/gul isolation ma kun tilsluttes en klemme market (IEC 417, No. 5019) eller (IEC 417, No. 5017)." If essential for the safety of the equipment, the tag must in addition be provided with a diagram, which shows the connection of the other conductors, or be provided with the following text: "For tilslutning af de ovrige ledere, se medfolgende installationsvejledning" Socket-outlets for providing power to other equipment shall be in accordance with the Heavy Current Regulations, Section D1, Standard Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For stationary equipment, the socket0outlet shall be in accordance with Standard Sheet DK 1-1b or DK 1-5a With the exception of CLASS II EQUIPMENT provided with a socket outlet in accordance with the Heavy Current Regulations, Section D1, Standard Sheet DK 1-4a, CLASS II EQUIPMENT shall not be fitted with socket-outlets for providing power to other equipment Supply cord of single-phase equipment having a rated current not exceeding 13 A shall be provided with a plug according to the Heavy Current Regulations, Section D1. Class I equipment provided with socket-outlets with earth contact or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules shall be provided with a plug in accordance with standard sheet DK 2-1a or DK 2-5a. If poly-phase equipment and single-phase equipment having a rated current exceeding 13 A is provided with a supply cord with a plug, this plug

54 Issue Date: Page 3 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict shall be in accordance with the Heavy Current Regulations, Section D1 or EN TOUCH CURRENT measurement results exceeding 3,5 ma r.m.s. are permitted only for PERMANENTLY CONNECTED EQUIPMENT and PLUGGABLE EQUIPMENT TYPE B. Finland - Differences to IEC :2005, Second Edition Resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in The third dashed sentence is applicable only to equipment as defined by this annex, Class I Pluggable Equipment Type A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text shall be: "Laite on liitettava suojamaadoitus-koskettimilla varustettuun pistorasiaan" Requirements according to this annex, and apply Requirements according to this annex, and apply Touch current measurement results exceeding 3,5 ma r.m.s are permitted only for the following equipment: - Stationary pluggable equipment Type A that: (1) is intended to be used in a Restricted Access Location where equipotential bonding has been applied, for example, in a telecommunication centre; and (2) has provision for a permanently connected protective earthing conductor; and (3) is provided with instructions for the installation of that conductor by a service person; - Stationary pluggable equipment Type B - Stationary permanently connected equipment Add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which

55 Issue Date: Page 4 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with EN :1994, subclass Y2. A capacitor classified Y3 according to EN :1994, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN :2006, ; - the additional testing shall be performed on all the test specimens as described in EN ; - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN The exclusions are applicable for permanently connected equipment and pluggable equipment type B and equipment intended to be used in a restricted access location where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected protective earthing conductor and is provided with instructions for the installation of that conductor by a service person. 7.2 Requirements according to this annex, and apply with the term telecommunication network in being replaced by the term cable

56 Issue Date: Page 5 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict distribution system. Germany - Differences to IEC :2005, Second Edition If for the assurance of safety and health certain rules during use, amending or maintenance of a technical labour equipment or readymade consumer product are to be followed, a manual in German language has to be delivered when placing the product on the market. Of this requirement, rules for use even only by SERVICE PERSONS are not exempted. Group - Differences to IEC :2005, Second Edition 1.3.Z1 Exposure to excessive sound pressure - The apparatus shall be so designed and constructed as to present no danger when used for its intended purpose, either in normal operating conditions or under fault conditions, particularly providing protection against exposure to excessive sound pressures from headphones or earphones. NOTE Z1 A new method of measurement is described in EN , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 1: General method for one package equipment, and in EN , Sound system equipment: Headphones and earphones associated with portable audio equipment - Maximum sound pressure level measurement methodology and limit considerations - Part 2: Guidelines to associate sets with headphones coming from different manufacturers Add the following NOTE Z1: The use of certain substances in electrical and electronic equipment is restricted within the EU: see Directive 2002/95/EC Add the following NOTE Z1: In addition, the instructions shall include, as far as applicable, a warning that excessive sound pressure from earphones and headphones can cause hearing loss Replace the subclause as follows: Basic requirements To protect against excessive current, short-circuits and earth faults in primary circuits, protective devices shall be included either as integral parts of the equipment or as parts of the building

57 Issue Date: Page 6 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict installation, subject to the following, a), b) and c): a) except as detailed in b) and c), protective devices necessary to comply with the requirements of 5.3 shall be included as parts of the equipment; b) for components in series with the mains input to the equipment such as the supply cord, appliance coupler, r.f.i. filter and switch, short-circuit and earth fault protection may be provided by protective devices in the building installation; c) it is permitted for pluggable equipment type B or permanently connected equipment, to rely on dedicated overcurrent and short-circuit protection in the building installation, provided that the means of protection, e.g. fuses or circuit breakers, is fully specified in the installation instructions. If reliance is placed on protection in the building installation, the installation instructions shall so state, except that for pluggable equipment type A the building installation shall be regarded as providing protection in accordance with the rating of the wall socket outlet Void Delete the NOTE and conduit sizes in parentheses in Table 3A Replace: "60245 IEC 53" by "H05 RR-F" "60227 IEC 52" by "H03 VV-F or H03 VVH2-F" "60227 IEC 53" by "H05 VV-F or H05 VVH2-F" In table 3B, replace the first four lines by the following: Up to and including a) Over 6 up to and including b) 1.0 Over 10 up to and including c) 1.5 In the conditions applicable to table 3B, delete the words "in some countries" in condition a). In Note 1, applicable Table 3B, to delete the second sentence In table 3D, delete the fourth line: conductor sizes for 10 to 13 A, and replace with the following: "Over 10 up to and including to to by 4" Delete the fifth line: conductor sizes for 13 to 16A Add the following NOTE Z1: Attention is drawn to 1999/519/EC: Council Recommendation on the limitation of exposure of the general public to electromagnetic fields 0 Hz to 300 GHz. Standards

58 Issue Date: Page 7 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict H taking into account this Recommendation which demonstrate compliance with the applicable EU Directive are indicated in the OJEC. Replace the last paragraph of this annex by: At any point 10 cm from the surface of the operator access area, the dose rate shall not exceed 1 gsv/h (0,1 mr/h) (see note). Account is taken of the background level. Replace the notes as follows: NOTE - These values appear in Directive 96/29/Euratom. Delete Note 2. Ireland - Differences to IEC :2005, Second Edition Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to I.S. 411 by means of that flexible cable or cord and plug, shall be fitted with a 13 A plug in accordance with Statutory Instrument 525: National Standards Authority of Ireland (section 28) (13 A Plugs and Conversion Adaptors for Domestic Use) Regulations DIRECT PLUG-IN EQUIPMENT is known as plug similar devices. Such devices shall comply with Statutory Instrument 526: National Standards Authority of Ireland (Section 28) (Electrical plugs, plug similar devices and sockets for domestic use) Regulations, Korea - Differences to IEC :2005, Second Edition Plugs for the connection of the apparatus to the mains supply shall comply withe the Korean requirement (KSC 8305) 8 EMC - The apparatus shall comply with the relevant CISPR standards Norway - Differences to IEC :2005, Second Edition Resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in Due to the IT power system used (see annex V, figure V.7), capacitors are required to be rated for the applicable phase-to-phase voltage ( 230 V) The third dashed sentence is applicable only to

59 Issue Date: Page 8 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict equipment as defined by this annex, Class I Pluggable Equipment Type A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text shall be: "Apparatet ma tilkoples jordet stikkontakt" Requirements according to this annex, , and apply Requirements according to this annex, and apply Requirements according to this annex, , and apply Requirements according to this annex, and apply Touch current measurement results exceeding 3,5 ma r.m.s are permitted only for the following equipment: - Stationary pluggable equipment Type A that: (1) is intended to be used in a Restricted Access Location where equipotential bonding has been applied, for example, in a telecommunication centre; and (2) has provision for a permanently connected protective earthing conductor; and (3) is provided with instructions for the installation of that conductor by a service person; - Stationary pluggable equipment Type B - Stationary permanently connected equipment Add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the

60 Issue Date: Page 9 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with EN :1994, subclass Y2. A capacitor classified Y3 according to EN :1994, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN :2006, ; - the additional testing shall be performed on all the test specimens as described in EN ; - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN The exclusions are applicable for permanently connected equipment and pluggable equipment type B and equipment intended to be used in a restricted access location where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected protective earthing conductor and is provided with instructions for the installation of that conductor by a service person. 7.2 Requirements according to this annex, and apply with the term telecommunication network in being replaced by the term cable distribution system. 7.3 There are many buildings where the screen of the coaxial cable is not normally connected to the earth in the building installation 7.3 Refer to EN :2005 for installation conditions Spain - Differences to IEC :2005, Second Edition

61 Issue Date: Page 10 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict Supply cords of single-phase equipment having a rated current not exceeding 10 A shall be provided with a plug according to UNE 20315:1994. Supply cords of single-phase equipment having a rated current not exceeding 2,5 A shall be provided with a plug according to UNE-EN 50075:1993. CLASS I EQUIPMENT provided with socket-outlets with earth contacts or which are intended to be used in locations where protection against indirect contact is required according to the wiring rules, shall be provided with a plug in accordance with standard UNE 20315:1994. If poly-phase equipment is provided with a supply cord with a plug, this plug shall be in accordance with UNE-EN Sweden - Differences to IEC :2005, Second Edition (Ordinance (1990:944)) Add NOTE: Switches containing mercury such as thermostats, relays and level controllers are not allowed Resistors bridging BASIC INSULATION in CLASS I PLUGGABLE EQUIPMENT TYPE A must comply with the requirements in The third dashed sentence is applicable only to equipment as defined by this annex, Class I Pluggable Equipment Type A intended for connection to other equipment or a network shall, if safety relies on connection to protective earth or if surge suppressors are connected between the network terminals and accessible parts, have a marking stating that the equipment must be connected to an earthed mains socket-outlet. The marking text shall be: "Apparaten skall anslutas till jordat uttag" Requirements according to this annex, and apply Requirements according to this annex, and apply Touch current measurement results exceeding 3,5 ma r.m.s are permitted only for the following equipment: - Stationary pluggable equipment Type A that: (1) is intended to be used in a Restricted Access Location where equipotential bonding has been applied, for example, in a telecommunication

62 Issue Date: Page 11 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict centre; and (2) has provision for a permanently connected protective earthing conductor; and (3) is provided with instructions for the installation of that conductor by a service person; - Stationary pluggable equipment Type B - Stationary permanently connected equipment "Add the following text between the first and second paragraph of the compliance clause: If this insulation is solid, including insulation forming part of a component, it shall at least consist of either - two layers of thin sheet material, each of which shall pass the electric strength test below, or - one layer having a distance through insulation of at least 0,4 mm, which shall pass the electric strength test below. If this insulation forms part of a semiconductor component (e.g. an optocoupler), there is no distance through insulation requirement for the insulation consisting of an insulating compound completely filling the casing, so that CLEARANCES and CREEPAGE DISTANCES do not exist, if the component passes the electric strength test in accordance with the compliance clause below and in addition - passes the tests and inspection criteria of with an electric strength test of 1,5 kv multiplied by 1,6 (the electric strength test of shall be performed using 1,5 kv), and - is subject to ROUTINE TESTING for electric strength during manufacturing, using a test voltage of 1,5 kv. It is permitted to bridge this insulation with a capacitor complying with EN :1994, subclass Y2. A capacitor classified Y3 according to EN :1994, may bridge this insulation under the following conditions: - the insulation requirements are satisfied by having a capacitor classified Y3 as defined by EN , which in addition to the Y3 testing, is tested with an impulse test of 2,5 kv defined in EN :2006, ; - the additional testing shall be performed on all the test specimens as described in EN ; - the impulse test of 2,5 kv is to be performed before the endurance test in EN , in the sequence of tests as described in EN "

63 Issue Date: Page 12 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict The exclusions are applicable for permanently connected equipment and pluggable equipment type B and equipment intended to be used in a restricted access location where equipotential bonding has been applied, e.g. in a telecommunication centre, and which has provision for a permanently connected protective earthing conductor and is provided with instructions for the installation of that conductor by a service person. 7.2 Requirements according to this annex, and apply with the term telecommunication network in being replaced by the term cable distribution system. 7.3 There are many buildings where the screen of the coaxial cable is not normally connected to the earth in the building installation Switzerland - Differences to IEC :2005, Second Edition Add NOTE: Switches containing mercury such as thermostats, relays and level controllers are not allowed Annex 2.15 of SR applies for batteries Supply cords of equipment having a rated current not exceeding 10 A shall be provided with a plug complying with SEV 1011 or IEC and one of the following dimension sheets: SEV , Plug type 15, 3P+N+PE 250/400 V,10 A SEV , Plug type 11, L+N 250 V,10 A SEV , Plug type 12, L+N+PE 250 V,10 A In general, EN applies for plugs for currents exceeding 10 A. However, a 16 A plug and socketoutlet system is being introduced in Switzerland, the plugs of which are according to the following dimension sheets, published in February 1998: SEV , Plug type 25, 3P+N+PE 230/400 V,16 A SEV , Plug type 21, L+N 250 V,16 A SEV , Plug type 23, L+N+PE 250 V,16 A Requirements according to this annex,

64 Issue Date: Page 13 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict apply USA / Canada - Differences to IEC :2005, Second Edition 1.1 Equipment able to be installed in accordance with the National Electrical Code ANSI/NFPA 70 and the Canadian Electrical Code, Part1, and when applicable, the National Electrical Safety Code, IEEE C Equipment able to be installed in accordance with ANSI/NFPA 75 and NEC Art. 645 unless intended for use outside of computer room and provided with such instructions Equipment in wire-line communication facilities serving high-voltage electric power stations operating at greater than 1kV are excluded Special requirements apply to equipment intended for use outdoors For Pluggable Equipment Type A, the protection in the installation is assumed to be 20 A All IEC standards for components identified in Annex P.1 replaced by the relevant requirements of CSA and UL component standards in Annex P All IEC standards for components identified in Annex P.2 alternatively satisfied by the relevant requirements of CSA and UL component standards in Annex P Interconnecting cables acceptable for the application regarding voltage, current, temperature, flammability, mechanical serviceability and the like For other than limited power and TNV circuits, the type of output circuit identified for output connector External cable assemblies that exceed 3.05 m in length to be types specified in the NEC and CEC Detachable external interconnecting cables 3.05 m or less in length and provided with equipment marked to identify the responsible organization and the designation for the cable Building wiring and cable for use in ducts, plenums and other air handling space subject to special requirements and excluded from scope Telephone line and extension cords and the like comply with UL 1863 and CSA C22.2 No Equipment intended for connection to a d.c. power (mains) distribution system is subject to special No external interconnecting flexible. No external interconnecting flexible.

65 Issue Date: Page 14 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict circuit classification requirements (e.g., TNV-2) Earthing of d.c. powered equipment provided. 1.7 Lamp replacement information indicated on lampholder in operator access area Special marking format for equipment intended for use on a supply system with an earthed neutral and more than one phase conductor Equipment voltage rating not higher than rating of the plug except under special conditions Special fuse replacement marking for operator accessible fuses Identification of terminal connection of the equipment earthing conductor Connectors and field wiring terminals for external Class 2 or Class 3 circuits provided with marking indicating minimum Class of wiring to be used Marking located adjacent to terminals and visible during wiring Bare TNV conductive parts in the interior of equipment normally protected against contact by a cover intended for occasional removal are exempt provided instructions include directions for disconnection of TNV prior to removal of the cover b Other telecommunication signaling systems (e.g., message waiting) than described in 2.3.1(b) are subject to M b b For TNV-2 and TNV-3 circuits with other than ringing signals and with voltages exceeding 42.4 Vp or 60 V d.c., the maximum current limit through a 2000 Ohm or greater resistor with loads disconnected is 7.1 ma peak or 30 ma d.c. under normal conditions. Limits for measurements across 5000 ohm resistor in the event of a single fault are replaced after 200 ms with the limits of M In the event of a single fault, the limits of apply to SELV circuits and accessible conductive parts Enamel coating on signal transformer winding wire allowed as an alternative to Basic insulation in specific telecommunication applications when subjected to special construction requirements and routine testing. 2.5 Overcurrent protection device required for Class 2

66 Issue Date: Page 15 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict and Class 3 limiting in accordance with the NEC, or for a Limited Power Source, not interchangeable with devices of higher ratings if operator replaceable. 2.6 Equipment having receptacles for output a.c. power connectors generated from an internal separately derived source have the earthed (grounded) circuit conductor suitably bonded to earth For Pluggable Equipment Type A, if a) b) or c) are not applicable, the current rating of the circuit is taken as 20 A Capacity of connection between earthing terminal and parts required to be earthed subject to special conditions based on the current rating of the circuit Protective bonding conductors and their terminals of non-standard constructions (e.g. PWB traces) evaluated to limited short-circuit test of CSA C22.2 No Field wiring terminals for earthing conductors suitable for wire sizes (gauge) used in US and Canada Data for selection of special external branch circuit overcurrent devices marked on the equipment Standard supply outlets protected by overcurrent device in accordance with the NEC, and CEC, Part Overcurrent protection for individual transformers that distribute power to other units over branch circuit wiring Additional requirements for overcurrent protection apply to equipment provided with panelboards Non-motor-operated equipment requiring special overcurrent protective device marked with device rating Multi-layer winding wire subject to UL component wire requirements in addition to and Annex U Permissible combinations of internal wiring/external cable sizes for overcurrent and short circuit protection All interconnecting cables protected against overcurrent and short circuit. 3.2 Wiring methods permit connection of equipment to primary power supply in accordance with the NEC Interconnecting cables comply with the relevant requirements of this standard.

67 Issue Date: Page 16 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict and CEC, Part Permitted use for flexible cords and plugs Flexible cords provided with attachment plug rated 125% of equipment current rating Any Class II equipment provided with 15 or 20 A standard supply outlets, Edison-base lampholders or single pole disconnect device provided with a polarized type attachment plug Equipment intended for connection to DC mains supply power systems complies with special wiring requirements (e.g., no permanent connection to supply by flexible cord) Equipment with one pole of the DC mains supply connected to both the equipment mains input terminal and the main protective earthing terminal provided with special instructions and construction provisions for earthing Equipment with means for connecting supply to earthing electrode conductor has no switches or protective devices between supply connection and earthing electrode connection Special markings and instructions for equipment with provisions to connect earthed conductor of a DC supply circuit to earthing conductor at the equipment Special markings and instructions for equipment with earthed conductor of a DC supply circuit connected to the earthing conductor at the equipment Terminals and leads provided for permanent connection of DC powered equipment to supply marked to indicate polarity if reverse polarity may result in a hazard Permanently connected equipment has provision for connecting and securing a field wiring system (i.e. conduit, or leads etc.) per the NEC and CEC, Part Permanently connected equipment may have terminals or leads not smaller than No. 18 AWG (0.82 mm2) and not less than 150 mm in length for connection of field installed wiring If supply wires exceed 60 XC, marking indicates use of 75 XC or 90 XC wiring for supply connection as appropriate Equipment compatible with suitable trade sizes of

68 Issue Date: Page 17 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict conduits and cables Length of power supply cord limited to between 1.5 and 4.5 m unless shorter length used when intended for a special installation Conductors in power supply cords sized according to NEC and CEC, Part I Power supply cords and cord sets incorporate flexible cords suitable for the particular application Strain relief provided for non-detachable interconnecting cables not supplied by a limited power source Adequate wire bending space and volume of field wiring compartment required to properly make the field connections Equipment intended solely for installation in Restricted Access Locations using low voltage d.c. systems may not need provision for connecting and securing a field wiring system. A method of securing wiring or instructions provided to ensure the wiring is protected from abuse. 3.3 Field wiring terminals provided for interconnection of units for other then LPS or Class 2 circuits also comply with Interconnection of units by LPS or Class 2 conductors may have field wiring connectors other than those specified in 3.3 if wiring is reliably separated Terminals for the connection of neutral conductor identified by a distinctive white marking or other equally effective means Wire binding screw terminal permitted for connection of No. 10 AWG (5.3 mm2) or smaller conductor if provided with upturned lugs, cupped washer or equivalent retention Terminals accept wire sizes (gauge) used in the U.S. and Canada Terminals accept current-carrying conductors rated 125% of the equipment current rating Field wiring terminals marked to indicate the material(s) of the conductor appropriate for the terminals used Connection of an aluminum conductor not permitted to terminal for equipment earthing conductor.

69 Issue Date: Page 18 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict Field wiring connections made through the use of suitable pressure connectors (including set screw type), solder lugs or splices to flexible leads Separate motor control device(s) required for cordconnected equipment rated more than 12 A, or with motor rated more than 1/3 hp or more than 120 V Vertically mounted disconnect devices oriented so up position of handle is "on" For computer-room applications, equipment with battery systems capable of supplying 750 VA for 5 min require battery disconnect means Special opening restrictions for enclosures around CRTs with face dimension of 160 mm or more Compartment housing high-pressure lamp marked to indicate risk of explosion For equipment intended for mounting on racks and provided with slide/rails allowing the equipment to slide away from the rack for installation, service and maintenance, additional construction, performance and marking requirements are applicable to determine the adequacy of the slide/rails Loading test for equipment with handle(s) used to support more than 9 kg tested at four times the weight of the unit In addition to the IEC requirements, Direct Plug-in Equipment complies with UL 1310 or CSA 223 mechanical assembly requirements The maximum quantity of flammable liquid stored in equipment complies with ANSI/NFPA 30(Table NAE.6) Equipment using replenishable liquids marked to indicate type of liquid to be used Equipment that produces x-radiation and does not comply with under all conditions of servicing marked to indicate the presence of radiation where readily visible Requirements contained in the applicable national codes and regulations apply to lasers (21 CFR 1040 and REDR C1370). 4.7 Automated information storage equipment intended to contain more than 0.76 m3 of combustible media requires provision for automatic sprinklers or a gaseous agent extinguishing system. No CRT. No flammable liquids within the equipment. No flammable liquids within the equipment Equipment for use in environmental air space other

70 Issue Date: Page 19 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict than ducts or plenums provided with metal enclosure or with non-metallic enclosure having adequate fire-resistance and low smoke producing characteristics. Low smoke-producing characteristics evaluated according to UL Equipment for installation in space used for environmental air as described in Sec (c) of the NEC provided with instructions indicating suitability for installation in such locations Flame spread rating for external surface of combustible material with exposed area greater than 0.93 m2 or a single dimension greater than 1.8 m; 50 or less for computer room applications or 200 or less for other applications Wire marked "VW-1" or "FT-1" considered equivalent Special earthing provisions and instructions for equipment with high touch current due to telecommunication network connections Touch current due to ringing voltage for equipment containing telecommunication network leads Overloading of SELV connectors and printed wiring board receptacles accessible to the operator Tests interrupted by opening of a component repeated two additional times Test interrupted by opening of wire or trace subject to certain conditions. 6 Specialized instructions provided for telephones that may be connected to a telecommunications network. 6 Marking identifying function of telecommunication type connectors not used for connection to a telecommunication network. 6.3 Equipment remotely powered over telecommunication wiring systems provided with specialized markings adjacent to the connection. 6.3 Overcurrent protection incorporated into equipment to provide power over telecommunication wiring system not interchangeable with devices of higher ratings if operator replaceable. 6.4 Additional requirements for equipment intended for connection to a telecommunication network using cable subject to overvoltage from power line failures (Fig. 6C). The equipment has no combustible material greater than 0.9m2 or single dimension greater than 1.8m Internal wiring is UL Recognized, marked VW-1 or FT-1 and strapped by individual cable ties. (See appended table 2.5)

71 Issue Date: Page 20 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict 6.4 Where 26 AWG line cord required by Fig. 6C, either the cord is provided with the equipment or described in the safety instructions. 7 Equipment associated with the cable distribution system may need to be subjected to applicable parts of Chapter 8 of the NEC. H Ionizing radiation measurements made under single fault conditions in accordance with the requirements of the Code of Federal Regulations 21 CFR 1020 and the Canadian Radiation Emitting Devices Act, REDR C1370. M.2 Continuous ringing signals evaluated to Method A subjected to special accessibility considerations. M.4 Special requirements for message waiting and similar telecommunications signals. NAC NAC Equipment intended for use with a generic secondary protector marked with suitable instructions. Equipment intended for use with a specific primary or secondary protector marked with suitable instructions. NAD Acoustic pressure from an ear piece less than 136 dba for short duration disturbances, and less than 125 dba for handsets, 118 dba for headsets, and 121 dba for insert earphones, for long duration disturbances. NAD Equipment connected to a telecommunication and cable distribution networks and supplied with an earphone intended to be held against, or in the ear is required to comply with special acoustic pressure requirements. NAF Household/Home Office Document Shredders NAF.1.7 Markings and instructions alert the user to key safety considerations related to use of shredders, including not intended to be used by children, avoid touching document feed opening, avoid clothes and hair entanglement, and avoid aerosol products. NAF Safety interlock cannot be inadvertently activated by the articulated accessibility probe (figure NAF.1). NAF.3.4 NAF.4.4 Provided with an isolating switch complying with 3.4.2, including 3 mm contact gap, with appropriate markings associated with the switch. Hazardous moving parts are not accessible, as determined using the articulated accessibility probe

72 Issue Date: Page 21 of 21 Report Reference # ASL IEC / EN Clause Requirement + Test Result - Remark Verdict (figure NAF.1) and the accessibility probe/wedge (figures NAF.2/NAF.3). United Kingdom - Differences to IEC :2005, Second Edition The current rating of the circuit shall be taken as 13 A, not 16 A To protect against excessive currents and shortcircuits in the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3 shall be conducted, using an external protective device rated 30 A or 32 A. If these tests fail, suitable protective devices shall be included as integral parts of the DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met Apparatus which is fitted with a flexible cable or cord and is designed to be connected to a mains socket conforming to BS 1363 by means of that flexible cable or cord and plug, shall be fitted with a "standard plug" in accordance with Statutory Instrument 1786: The Plugs and Sockets etc. (Safety) Regulations 1994, unless exempted by those regulations. NOTE: "Standard plug" is defined in SI 1786: 1994 and essentially means an approved plug conforming to BS 1363 or an approved conversion plug A power supply cord with conductor of 1.25 mm2 is allowed for equipment with a rated current over 10A and up to and including 13A The range of conductor sizes of flexible cords to be accepted by terminals for equipment with a rated current of over 10 A up to and including 13 A is 1.25 mm2 to 1.5 mm2 nominal cross-sectional area The torque test is performed using a socket outlet complying with BS 1363 part 1:1995, including Amendment 1:1997 and Amendment 2:2003 and the plug part of DIRECT PLUG-IN EQUIPMENT shall be assessed to BS 1363: Part 1, 12.1, 12.2, 12.3, 12.9, 12.11, 12.12, 12.13, and 12.17, except that the test of is performed at not less than 125 o C. Where the metal earth pin is replaced by an Insulated Shutter Opening Device (ISOD), the requirements of clauses 22.2 and 23 also apply. The power cord is not provided with the equipment.

73 Issue Date: Page 1 of 28 Report Reference # ASL Enclosure Photographs Supplement Id Description 3-01 Top view 3-02 Bottom view (1) 3-03 Bottom view (2) 3-04 Bottom view (with VGA) 3-05 Bottom view (without VGA) 3-06 Right side view 3-07 Left side view 3-08 Open view 3-09 Inside view 3-10 Top view for mother board type A15HC 3-11 Bottom view for mother board type A15HC 3-12 Top view for IO board type A15HC IO BOARD 3-13 Bottom view for IO board type A15HC IO BOARD 3-14 Battery pack top view for model A32-A Battery pack bottom view for model A32-A Battery pack cell type_icr for model A32-A Battery pack Inside view for model A32-A Battery pack protection board top view for model A32-A Battery pack protection board bottom view for model A32-A Battery pack top view for model A42-A Battery pack bottom view for model A42-A Battery pack cell type_icr for model A42-A Battery pack cell type_icr18650b3 for model A42-A Battery pack Inside view for model A42-A15 (with cell type_ ICR ) 3-25 Battery pack Inside view for model A42-A15 (with cell type_ ICR18650B3) 3-26 Battery pack protection board top view for model A42-A Battery pack protection board bottom view for model A42-A15

74 Issue Date: Page 2 of 28 Report Reference # ASL Photographs ID 3-01

75 Issue Date: Page 3 of 28 Report Reference # ASL Photographs ID 3-02

76 Issue Date: Page 4 of 28 Report Reference # ASL Photographs ID 3-03

77 Issue Date: Page 5 of 28 Report Reference # ASL Photographs ID 3-04

78 Issue Date: Page 6 of 28 Report Reference # ASL Photographs ID 3-05

79 Issue Date: Page 7 of 28 Report Reference # ASL Photographs ID 3-06

80 Issue Date: Page 8 of 28 Report Reference # ASL Photographs ID 3-07

81 Issue Date: Page 9 of 28 Report Reference # ASL Photographs ID 3-08

82 Issue Date: Page 10 of 28 Report Reference # ASL Photographs ID 3-09 (With VGA) (Without VGA)

83 Issue Date: Page 11 of 28 Report Reference # ASL Photographs ID 3-10 (With VGA) (Without VGA)

84 Issue Date: Page 12 of 28 Report Reference # ASL Photographs ID 3-11 (With VGA) (Without VGA)

85 Issue Date: Page 13 of 28 Report Reference # ASL Photographs ID 3-12

86 Issue Date: Page 14 of 28 Report Reference # ASL Photographs ID 3-13

87 Issue Date: Page 15 of 28 Report Reference # ASL Photographs ID 3-14

88 Issue Date: Page 16 of 28 Report Reference # ASL Photographs ID 3-15

89 Issue Date: Page 17 of 28 Report Reference # ASL Photographs ID 3-16

90 Issue Date: Page 18 of 28 Report Reference # ASL Photographs ID 3-17

91 Issue Date: Page 19 of 28 Report Reference # ASL Photographs ID 3-18

92 Issue Date: Page 20 of 28 Report Reference # ASL Photographs ID 3-19

93 Issue Date: Page 21 of 28 Report Reference # ASL Photographs ID 3-20

94 Issue Date: Page 22 of 28 Report Reference # ASL Photographs ID 3-21

95 Issue Date: Page 23 of 28 Report Reference # ASL Photographs ID 3-22

96 Issue Date: Page 24 of 28 Report Reference # ASL Photographs ID 3-23

97 Issue Date: Page 25 of 28 Report Reference # ASL Photographs ID 3-24

98 Issue Date: Page 26 of 28 Report Reference # ASL Photographs ID 3-25

99 Issue Date: Page 27 of 28 Report Reference # ASL Photographs ID 3-26

100 Issue Date: Page 28 of 28 Report Reference # ASL Photographs ID 3-27

101 Issue Date: Page 1 of 5 Report Reference # ASL Enclosure Schematics + PWB Supplement Id Description 5-01 RTC Battery Protection Circuit for M/B model: A15HC 5-02 USB Protection Circuit for M/B model: A15HC 5-03 HDMI Protection Circuit for M/B model: A15HC 5-04 USB Protection Circuit for I/O Board model: A15HC IO BOARD

102 Issue Date: Page 2 of 5 Report Reference # ASL Schematics + PWB ID 5-01

103 Issue Date: Page 3 of 5 Report Reference # ASL Schematics + PWB ID 5-02

104 Issue Date: Page 4 of 5 Report Reference # ASL Schematics + PWB ID 5-03

105 Issue Date: Page 5 of 5 Report Reference # ASL Schematics + PWB ID 5-04

106 Issue Date: Page 1 of 3 Report Reference # ASL Enclosure Manuals Supplement Id Description 6-01 Safety Instruction written in manual

107 Issue Date: Page 2 of 3 Report Reference # ASL Manuals ID 6-01

108 Issue Date: Page 3 of 3 Report Reference # ASL Manuals ID 6-01

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2005-08-06 Page 1 of 1 Report Reference # E137006-A6-CB-1 COVER PAGE FOR TEST REPORT Test Item Description: Model/Type Reference: Rating(s): Standards: Applicant Name and Address: Factory Location(s):

More information

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address

Applicant s address. Identification: (Model No.) Serial No.: Lab Name Lab address Test Report No.: xx001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Applicant s Name Applicant s address Test item: Set Top Box Identification: (Model No.) Serial No.: Receipt No.: Date of receipt:

More information

Information technology equipment Safety Part 1: General requirements

Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜV SÜD PSB Pte Ltd 1 Science Park Drive, Singapore 118221 TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 257636 Date of issue... :

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number....: CB110708E01 001 Date of issue...: August 10,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2007-05-22 Page 1 of 2 Report Reference # E116994-A35-CB-1 Amendment 1 2008-04-24 COVER PAGE FOR TEST REPORT Test Item Description: DC Power Supplies Model/Type Reference: Class I Models: GNT2XXX-YYY

More information

< > Page 2 of 84

< > Page 2 of 84 age 2 of 84 articulars: test item vs. test requirements Equipment mobility...: Building-in Operating condition...: Continuous Mains supply tolerance (%)...: -10%, +10% Tested for IT power systems...: Yes

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General requirements Report Reference No....: 3156776MIN-001 Date of issue...: 2008-07-30

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510050STO-001 Date of issue... : 26 October

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 1510053STO-001 Date of issue... : 2 November

More information

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L TEST REORT Low Voltage Directive 2006/95/EC Report No.: STDGZ-01721-L 8th Floor, Block B,No.11 Caipin Road,GZ Science City,Tianhe, Guangzhou 510663, China TEST REORT IEC/EN 62040-1 Uninterruptible power

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements Report Number.... : CB170707E03 001 Date of issue... : 2017-08-23

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-07-23 Page 1 of 2 Report Reference # E199929-A2-UL-2 COVER PAGE FOR TEST REPORT Product Category: Power Supplies for Information Technology Equipment Including Electrical Business Equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: NCB TÜ V SÜ D SB te Ltd 1 Science ark Drive, Singapore 118221 TEST REORT IEC 60950-1 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of Fujitsu Technology Solutions GmbH Product Compliance Center Restricted TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-25 Page 1 of 65 Report Reference # E122103-A137-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 221868-CI3-2 CB DE1-56824 Date of issue...

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2006-05-11 Page 1 of 2 Report Reference # E212360-A19-UL-1 Amendment 2 2009-07-03 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference:

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2015-06-26 Page 1 of 73 Report Reference # E122103-A140-CB-2 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd.

LVD TEST REPORT EN : 2006+A12: MEASUREMENT AND TEST REPORT For. Ingtron Enterprise Co., Ltd. LVD TEST REORT EN 60950-1: 2006+A12: 2011 MEASUREMENT AND TEST REORT For Ingtron Enterprise Co., Ltd. No. 211-1, Qingfeng Road, Qingxi Town, Dongguan City, Guangdong, China Model: reference page 2 Feb.

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number... : 30581696.032 Date of issue... : 14 July 2015

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-04-01 Page 1 of 8 Report Reference # E229738-A1-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009.

ELECTRICAL TESTING EN : A11: A1: A12:2011, IEC :2005 (Second Edition) + Am1:2009. ELECTRICAL TESTING 839.01 Hermon Laboratories Ltd. Tel.+972 4 628 8001 Fax.+972 4 628 8277 SAFETY TEST REPORT ACCORDING TO: EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011, IEC 60950-1:2005 (Second Edition)

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2017-10-25 Page 1 of 8 Report Reference # E132002-A448- TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: 60950-1, 2nd Edition, 2014-10-14 (Information Technology

More information

:2006+A11:2009+A1:2010+A12:2011+A2:2013

:2006+A11:2009+A1:2010+A12:2011+A2:2013 Page 1 of 55 Report No.:L611332L009 LOW VOLTAGE DIRECTIVE TEST REPORT IEC 60950-1:2005 (2nd Edition) Am 1:2009 Am 2:2013 and/or EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 Information technology

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-03-23 Page 1 of 16 Report Reference # E186249-A202-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 72 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No...:

More information

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance. 12012453 003 age 2 of 6 Summary of testing The clause 17 and clause 29 are considered and check on the appliance. Test items particulars Serial umber... : rototype samples Additional information... : (.A.)...

More information

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY

Test Report No.: Xxxx 001 Page 1 of xx. Receipt No.: Date of receipt: DD/MM/YYYY Test Report No.: Xxxx 001 Page 1 of xx Issue Date: DD/MM/YYYY Manufacturer: Test item: Identification: Serial No.: Receipt No.: Date of receipt: DD/MM/YYYY Testing laboratory and its address: Test specification:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-2 CB DE1-49619/A2/B1/M2 Date

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0347/14 Date of issue... : 2014-12-05

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements dftfdthdxfgxfx Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31182226.016 Date of issue...

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : T223-0358/16 Date of issue... : 2016-07-14 Total number

More information

Amendment to Test Report

Amendment to Test Report Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements Page 1 of 49 Report Reference No....: 81790 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2009 TEST REPORT :2006 Information technology equipment Safety Part 1: General

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2016-04-08 Page 1 of 24 Report Reference # E186249-A263-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2014-10-14 (Information

More information

IEC Information technology equipment Safety Part 1: General requirements

IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of www.nemko.com TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 248792 Date of issue... : 2013-11-25

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2008-11-11 Page 1 of 2 Report Reference # E186249-A82-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: GLOBAL ADVANTAGE INTERNATIONAL TEST REPORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety Part 1: General

More information

Installation Couplers intended for permanent connection in fixed installation

Installation Couplers intended for permanent connection in fixed installation Test Report issued under the responsibility of: TEST REORT Installation Couplers intended for permanent connection in fixed installation Report Reference No....: 2167493.50-DCC Date of issue...: 2013-11-26

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements

TEST REPORT IEC Information technology equipment - Safety - Part 1: General requirements Issue Date: 2017-10-20 Page 1 of 11 Report Reference # E135494-A115-CB-1 Test Report issued under the responsibility of: Report Reference No... : TEST REPORT IEC 60950-1 Information technology equipment

More information

Test Report issued under the responsibility of: BA-10CA08002-K-1 Date of issue... : Total number of pages Report Reference No...

Test Report issued under the responsibility of: BA-10CA08002-K-1 Date of issue... : Total number of pages Report Reference No... Test Report issued under the responsibility of: TEST REPORT IEC 62133, First Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed

More information

Low Voltage Directive Report

Low Voltage Directive Report Low Voltage Directive Report SUPERIOR PRODUCT CONSULTION, INC 3F, NO. 10, ALLEY 6, LANE 235, PAO CHIAO RD., HSIEN TIEN, TAIPEI, TAIWAN R. O. C. 235 6 1 0 3 F TEL:886-29174137 FAX:556-2-29184517 The test

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : UNI2015122413SR-01 Date of issue... : 2015-12-22 Total number of pages... 42 Tested by (+ signature) Steven

More information

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus

Universal Standard Service, Inc. Test Report No.:CERASL Test Report. : Micro-Star Int'l Co., Ltd. : Wireless 11g CardBus Test Report o.:cerasl03071001 Test Report Applicant Address Product ane : Micro-Star Int'l Co., Ltd. : o. 69, Li-De St., Jung-He City, Taipei Hsien 235, Taiwan : Wireless 11g CardBus Type Designation :

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Page 1 of 46 TEST REPORT Information technology equipment Safety Part 1: General requirements Report Number.... : 160414015SZN-002 Date of issue... : May 09, 2016 Total number of pages... : 77 pages Applicant

More information

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences:

Summary of testing: Tests performed (name of test and test clause): Testing location: Summary of compliance with National Differences: age 3 of 106 Summary of testing: Tests performed (name of test and test clause): All applicable tests as described in Test Case and Measurement Sections were performed. re-production samples without serial

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2012-08-17 Page 1 of 21 Report Reference # E186249-A203-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: UL 60950-1, 2nd Edition, 2011-12-19 (Information

More information

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... : Test Report issued under the responsibility of: TEST REORT IEC 60898-1 Circuit-breakers for over current protection for household and similar installations art 1 - Circuit-breakers for a.c. operation Report

More information

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages... Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT Information technology equipment Safety art 1: General requirements Report Number.... : 1712057S.50A Date of issue... : 2017-04-13 Total number

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number....: T223-0035/16 Date of issue...: 2016-02-01

More information

A Test Lab Techno Corp.

A Test Lab Techno Corp. Report No. 1607CF12 age 1 of 52 TEST REORT AS/NZS60950.1:2011+A1:2013 Safety of Information Technology Equipment including Electrical business equipment Report Number.... : 1607CF12 Date of issue... :

More information

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS

TECHNICAL REPORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC REPORT NO REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT NERA SATCOM AS ELECTRICAL SAFETY TESTING OF DC/DC CONVERTER FOR THE NERA F77 SYSTEM REORT NO. 2004-3405 REVISION NO. 02 DET NORSKE VERITAS TECHNICAL REORT Table of Content age 1 SCOE OF

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2010-07-30 Page 1 of 6 Report Reference # E313912-A35-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): COVER PAGE FOR TEST REPORT Power Supplies for Information Technology Equipment Including Electrical Business

More information

TEST REPORT EN LED modules for general lighting Safety specifications

TEST REPORT EN LED modules for general lighting Safety specifications TEST REORT LED modules for general lighting Safety specifications Report Reference No...: 3007562.51-QUA/LI Date of issue...: 2011-03-28 Total number of pages... CB Testing Laboratory...: Address...: Applicant

More information

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires TEST REPORT PN-EN 13032 Light and lighting. Measurement and presentation of photometric data of lamps and luminaires Report Number.... : BS-3/161/B/5/15 Date of issue... : 03.02.2016 Total number of pages...

More information

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements

TEST REPORT EN , Second Edition Information technology equipment Safety Part 1: General requirements age 1 of 25 Report reference o.: B-S10060512 TEST REORT E 60950-1, Second Edition Information technology equipment Safety art 1: General requirements Report reference o..... : B-S10060512 Tested by (printed

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements Report Reference No....:

More information

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT. IEC 62133: 2012 (Second Edition) Test Report issued under the responsibility of: TEST REORT, Second Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary

More information

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors r Test Report issued under the responsibility of: TEST REORT Low-voltage switchgear and control gear art 7-4: Ancillary equipment CB terminal blocks for copper s Report Number.... : 2169331.75 Date of

More information

Page 3 of 34 Report No Part I

Page 3 of 34 Report No Part I www.tuv.com age 3 of 34 Report No. 14717090 001 art I List of Attachments (including a total number of pages in each attachment): Besides of the tests according to : 2008 +A1 +A2, the following tests are

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L12 Date of issue...: 2016-11-28 Total number of pages... 25 pages Testing Laboratory...

More information

TEST REPORT DIN V VDE V

TEST REPORT DIN V VDE V Test Report issued under the responsibility of: TEST REORT DIN V VDE V 0126-1-1 Report Number....: EFSH16041203-IE-01-L21 Date of issue...: 2016-11-28 Total number of pages... 26 pages Testing Laboratory...

More information

page 2 of 82 IEC 60950

page 2 of 82 IEC 60950 page 2 of 82 articulars: test item vs. test requirements Equipment mobility...: For building-in Connection to Mains Built in equipment, not intended for direct connection to mains Operating condition...:

More information

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc. Test Report issued under the responsibility of: TEST REORT IEC 62133, First Edition Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed

More information

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60884-1 Plugs and socket-outlets for household and similar purposes Part 1: General requirements Report Reference No.... : Date of issue...

More information

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements

TEST REPORT EN Household and similar electrical appliances Part 1: General requirements TEST REORT E 60335-1 Household and similar electrical appliances art 1: General requirements Report reference o....: TK-CL100151 Tested by (printed name and signature)...: Kyoung Moon, Choi... Approved

More information

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT EN :2006 Information technology equipment Safety Part 1: General requirements age 1 of 49 Report Reference No....: 80983 Test Report issued under the responsibility of: MET Laboratories, Inc. Copyright 2008 TEST REORT :2006 Information technology equipment Safety art 1: General

More information

Luminaire for road and street lighting. Approved by / Authorized Signatory:

Luminaire for road and street lighting. Approved by / Authorized Signatory: Test Report No.: Page 1 of 35 Issue Date: Manufacturer: Test item: Luminaire for road and street lighting Identification: Serial No: Receipt No.: Date of receipt: Testing laboratory and its address: Test

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Report Number.... : TEST REORT Information technology equipment Safety art 1: General requirements Date of issue... : 7 March, 2017 Total number of pages...

More information

PSC Product Safety Consultant Inc.

PSC Product Safety Consultant Inc. age : 2 of 52 Operating condition...: Mains supply tolerance (%)...: Tested for IT power systems...: IT testing, phase-phase voltage (V) : Mass of equipment (kg)...: rotection against ingress of water.:

More information

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard Doc: ET 31(6126) BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY (Not to be reproduced without the permission of BIS or used as a STANDARD) Draft Indian Standard UNINTERRUPTIBLE POWER SYSTEMS (UPS)

More information

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 1 of 15 L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD age 2 of 15 SUMMARY TEST REORT BS EN 61029-1: 2000, with BS EN 61029-2-4: 2003 Safety of transportable motor-operated

More information

Test Report issued under the responsibility of: Report Number...:

Test Report issued under the responsibility of: Report Number...: Test Report issued under the responsibility of: TEST REORT Secondary cells and batteries containing alkaline or other non-acid electrolytes Safety requirements for portable sealed secondary cells, and

More information

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires Test Report issued under the responsibility of www.nemko.com Report Reference No.... : 220130 Date of issue... : 2012-09-13 Total number of pages... 6 TEST REPORT IEC 60598-2-2 Luminaires Part 2: Particular

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2003-09-25 Page 1 of 1 Report Reference # E203413-A17-CB-1 Test Item Description: Model/Type Reference: COVER PAGE FOR TEST REPORT Home Plug Device MS-6821 Rating(s): 100-240 Vac, 47-63 Hz,

More information

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC : 2005 (2nd Edition) and/or EN :2006 Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: Kontron Embedded Computer GmbH TEST REORT IEC 60950-1: 2005 (2nd Edition) and/or EN 60950-1:2006 Information technology equipment Safety art 1: General requirements

More information

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200

APPLICATION FOR LOW VOLTAGE DIRECTIVE. On Behalf of GUANGDONG EAST POWER CO., LTD. Uninterruptible Power Supply. Model(s): EA99300,EA99250,EA99200 ALICATIO FOR LOW VOLTAGE DIRECTIVE On Behalf of GUAGDOG EAST OWER CO., LTD. Uninterruptible ower Supply Model(s): EA99300,EA99250,EA99200 repared For : GUAGDOG EAST OWER CO., LTD. o.6 orthern Industry

More information

UL TEST REPORT AND PROCEDURE

UL TEST REPORT AND PROCEDURE Issue Date: 2011-03-18 Page 1 of 11 Report Reference # E300305-A58-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology Equipment

More information

NCB Intertek Testing Services NA, Inc.

NCB Intertek Testing Services NA, Inc. Test Report issued under the responsibility of: NCB Intertek Testing Services NA, Inc. TEST REORT Safety requirements for electrical equipment for measurement, control, and laboratory use art 1: General

More information

Presented to the IAPMO Standards Review Committee on December 9, 2013

Presented to the IAPMO Standards Review Committee on December 9, 2013 Summary of Substantive Changes between the 2010 edition including Updates No. 1 and No. 2 dated September 2010 and August 2011 and the 2013 edition of CSA C22.2 No. 14 Industrial control equipment Presented

More information

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

This standard covers the requirements of lighting chains. This standard covers only the safety requirements. FOREWORD (Formal clause will be added later) This standard covers the requirements of lighting chains. This standard covers only the safety requirements. This standard (Part 5/Section 7) is one among the

More information

COVER PAGE FOR TEST REPORT

COVER PAGE FOR TEST REPORT Issue Date: 2009-05-26 Page 1 of 2 Report Reference # E310405-A9-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Power Supplies for

More information

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS 013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEYLON ELECTRICITY BOARD SRI LANKA Specification for MOULDED CASE CIRCUIT BREAKERS FOR OVERHEAD NETWOKS CEB Specification