1 1/4 (32A) to 2 (50A) added.

Size: px
Start display at page:

Download "1 1/4 (32A) to 2 (50A) added."

Transcription

1 Coolant Valve 0.5 MPa.0 MPa.6 MPa /4 (3) to (50) added. RoHS IP65 compliant For pilot valve V6 Flow rate Variations New Series SC SC3 SC4 SC5 Cv (kv) (5.6) Cv (For 0.5 MPa specification).8 (0.) 8.3 (5.7) 8 (4) Port size 3/8 (0), / (5) 3/4 (0) (5) /4 (3) Service life: 5 million cycles or more (For the SC, 3, 4, based on SMC s test condition) Power consumption: 0.35 W * /.8 W * * For 4 VC New New SC6 SC7 43 (36.9) 70 (60) / (40) (50) Water hammer: Reduced by 30% * * Compared to current model, VNC series * For 0.35 W type, SC to 7 M connector Thread type: Rc,, NPT, NPTF With auto switches for verifying whether the valve is open/closed Series SC CT.ES70-3B

2 Coolant Valve Series SC (For ir Operated Type) ry bearings uto switch Prevents the shaft, which is a sliding part, from vibrating and helps to extend the service life of the rubber components and improves the seal performance of the main valve. ble to confirm whether the valve is open/ closed. Mountable on the sides. (SC, 3, 4 only) Squeeze seal Completely shuts off the leakage of liquid coolant and increases the scraper effects. These two safety designs result in a dual advantage. Scraper Prevents foreign matter from entering, while the main valve is activated. Magnet (SC, 3, 4 only) Choice of seal materials rease channel NBR, FKM Prevents the loss of grease and helps to extend the service life. IN OUT For External Pilot Solenoid Type SC SC3 SC4 SC5 SC6 SC7 Note ) Note ) ) * * * Type 0.35 W type.8 W type 0.35 W type.8 W type Note ) For C voltage. Refer to page 7 for models with indicator light and C voltage (apparent power V). Note ) The response time is equivalent to the VNC series. * Made to Order (See page 6.) Variations (Common specifications for external pilot solenoid type and air operated type) Series Port size Thread type Type of Operating pressure range Cv [MPa] actuation /8 (0) SC / (5) SC3 SC4 3/4 (0) (5) Rc (ISO79-) NPT NPTF N.C./N.O. kv New SC5 /4 (3) New SC6 / (40) New SC7 (50) Electrical entry (For external pilot solenoid type) Bracket Bracket on the left side Conduit terminal Bracket on the right side IN terminal M connector

3 Reduced Coolant Blow Energy Consumption Reduced electric power for coolant pump Reduced number of pump units Pump downsized Coolant pump 30% Oil hydraulic pump, etc. 50% ir compressor 0% Electric power consumption by purpose (SMC research) Research has revealed that coolant pumps account for 30% of the electric power consumption in a production facility. By reducing the energy consumption for coolant blow, it will substantially contribute to the electric reduction in the whole factory. Improvement Example case Improvement in Pressure Loss Before improvement fter improvement Coolant valve Nozzle P Large diameter piping S Effective area ratio : Small diameter nozzle S ø6 Pressure loss: Small Pressure loss is improved by making the effective area ratio : between the upstream side and the nozzle. Making the effective area in the upstream side larger. (Changing to the equipment with larger effective area) ttaching a nozzle. Effect of Energy Saving Improvement Pump head (Electric power) Pump capacity ischarge rate Previous rate Pump outlet Pressure Pressure loss: Small Nozzle outlet Electric power consumption 75% reduction Improvement Example case Intermittent Blow P For cutting (Blade cooling) For jig (Reference surface cleaning) Machine bed washing (Washing chips) Stops machine bed-washing all the time. Machine bed washing is stopped when blowing for cutting or jig by means of a valve. ddition of coolant valve Effect of Energy Saving Improvement Coolant flow per cycle Flow For cutting For jig For cutting Machine bed washing Coolant flow per cycle Flow Machine bed washing For cutting For jig For cutting Flow inside the dotted line will be reduced. Machine bed washing Electric power consumption 0 to 50% reduction cycle cycle

4 Coolant Blow System/ Related Equipment Coolant pump 3-Color isplay Electromagnetic Type igital Flow Switch LFE Coolant Valve Series SC W Pressure Switches Coolant line pressure control -Color isplay igital Pressure Switch ISE80 Coolant liquid filtration Filters Nozzles for Blowing Nozzles for Blowing KN -Color isplay igital Pressure Switch ISE75/75H eneral Purpose Pressure Switch IS Industrial Filter F Bag Filter FF Low Maintenance Filter FN Energy Saving Related Materials Water Resistant Cylinders For details, refer to the SMC website. SMC Model Selection Software Search For details, refer to the WEB catalog or the Best Pneumatics No. catalog. 3

5 CONTENTS Coolant Valve Series SC How to Order Page 5 Characteristics Page 6 Valve Specifications Page 6 How to Order Pilot Valves Page 7 Pilot Solenoid Valve Specifications Page 7 Construction Page 8 imensions ir Operated Page 9 External Pilot Solenoid Page 0 How to Fix an uto Switch Page 3 uto Switch Proper Mounting Position Page 3 Options Page 3 uto Switch Page 4 Made to Order Page 6 Specific Product Precautions Page 7 4

6 Coolant Valve Series SC How to Order Made to Order (For details, refer to page 6.) ir Operated SC External Pilot Solenoid q Series SC00 3 SC300 4 SC400 5 SC500 6 SC600 7 SC700 SC w Valve type N.C. N.O T Z q w e r t y u i o!0!!!3!4!5 e Seal material NBR B FKM r Pressure range 05 0 to 0.5 MPa 0 0 to MPa 6 * 0 to.6 MPa * Only available for series, 3, 4. t Thread type Nil Rc (ISO79-) N NPT T NPTF u Pilot valve Symbol Pilot valve SC SC3 SC4 SC5 SC6 SC7 Y 0.35 W type (V6) H.8 W type (VO307) * * * Note) 0.35 W type (Pilot valve V6) is a low wattage specification. The response is slower than VNC series. If the response time is a problem, use the.8 W type (VO307). Please note that the power consumption is.8 W (With indicator light: W). * SC/3/4-X (See page 6.) Y y Port size 0 3/8 5 / SC00 0 3/4 SC300 5 SC400 3 /4 SC / SC SC700 i Rated voltage 00 VC 50/60 Hz 00 VC 50/60 Hz 3 0 VC [5 VC] 50/60 Hz 4 0 VC [30 VC] 50/60 Hz 5 4 VC 6 VC Note) Refer to page 7 when using with energization for long periods of time.!0 Light/surge voltage suppressor Nil None S With surge voltage suppressor With light/surge voltage Z suppressor Note) Refer to Table () below for combinations with electrical entry. o Electrical entry T: Conduit terminal : IN terminal (Pilot valve V6 only) Note ) (Pitch between the terminals: mm) O: IN terminal W: M connector without connector Note ) (4-pin type) Note 3) V: M connector (5-pin type) Note 3) 4) Note ) Refer to the table () below for combinations with light/surge voltage suppressors. Note ) Not available for H (.8 W type). Note 3) Cable for M connector is not included. Order it separately after referring to the options on page 3. Note 4) Only C voltage is available.! Manual override Nil: Non-locking push type : Push-turn locking lever type! Bracket mounting position Nil: Without bracket B: Bracket on the left side Left IN Right B: Bracket on the right side Left IN Right Table () Electrical Entry/Light/Surge Voltage Suppressor Pilot valve 0.35 W type (V6) Rated voltage C C Electrical entry T W Note) Bracket cannot be attached later. * Only available for series, 3, 4. Without light/surge voltage suppressor With surge voltage suppressor With light/surge voltage suppressor Nil S Z V V O V Note) T V V V W, V O V C W V V.8 W type (VO307) O C W, V O V V Note) When C voltage (V6) without IN terminal (O) is selected, always use a IN connector with surge voltage suppressor as the connector. 5

7 Coolant Valve Series SC!3 uto switches (for verifying whether the valve is open/closed) Nil Without auto switch (without magnet) M Without auto switch (with built-in magnet) B C E F With auto switch Select a model, referring to the table pplicable uto Switches below. * uto switches are shipped together, (but not assembled). * Only available for series, 3, 4. Symbol Type of actuation N.C. N.O. ir operated External pilot solenoid SC SC SC SC!4 Lead wire length Nil 0.5 m M m L 3 m Z 5 m * 0.5 m (Nil), m (M), and 5 m (Z) for -M9 will be produced on receipt of order. * Only available for series, 3, 4.!5 Number of auto switches Nil pcs. S pc. * Only available for series, 3, 4. pplicable uto Switches/ Refer to the WEB catalog or the Best Pneumatics No. catalog for detailed auto switch specifications. Solid State uto Switch Part no. Special Electrical Indicator Wiring Load voltage Symbol pplicable load In-line function entry light (Output) C -M9N 3-wire (NPN) 5 V, V IC circuit Relay, B -M9P rommet Yes 3-wire (PNP) 4 V PLC C -M9B -wire V E -M9N 3-wire (NPN) Water resistant 5 V, V IC circuit Relay, F -M9P rommet Yes 3-wire (PNP) 4 V (-color indication) PLC -M9B -wire V Characteristics Pressure type 0.5 MPa.0 MPa.6 MPa Model Flow-rate Weight [kg] Port Orifice dia. Cv factor characteristics size ø [mm] converted External pilot v x 0 6 m ir operated solenoid SC() /8 ø (0.74) 0.73 (0.78) SC() / ø (0.74) 0.73 (0.78) SC() /4 ø (.).08 (.5) SC() ø (.77).74 (.8) SC() /4 ø SC() / ø SC() ø SC() /8 ø (0.74) 0.73 (0.78) SC() -0 5 / ø (0.74) 0.73 (0.78) SC() /4 ø (.).08 (.5) SC()4-0 5 ø (.77).74 (.8) SC()5-0 3 /4 ø SC() / ø SC() ø SC() /8 ø (0.74) 0.73 (0.78) SC() -6 5 / ø (0.74) 0.73 (0.78) SC() /4 ø (.).08 (.5) SC()4-6 5 ø (.77).74 (.8) * ( ): Weight including the bracket * dd the weight of an auto switch additionally. Valve Specifications Fluid Coolant (Water cannot be used.) Fluid temperature SC, B 5 to 60 C * mbient temperature 5 to 50 C Proof pressure SC(), SC()3, SC()4.4 MPa SC()5, SC()6, SC()7.5 MPa Leakage from the valve seat 0 cm 3 /min or less (Coolant pressure) SC to 0.5 MPa Operating SC -0 0 to MPa pressure range SC -6 0 to.6 MPa (Series, 3, 4 only) SC 0.5 to 0.7 MPa Pressure 0.5 MPa type: 0.5 MPa to 0.7 MPa External pilot SC.0,.6 MPa type: 0.3 MPa to 0.7 MPa air Lubrication Not required (Use turbine oil Class (ISO V3), if lubricated.) Temperature 5 to 50 C * * No freezing 6

8 Series SC How to Order Pilot Valves 0.35 W Type V6 5 T Z q w e Pilot Solenoid Valve Specifications Pilot solenoid valve V6- - Electrical entry Conduit terminal, IN terminal, M connector rated C V, 4 V voltage [V] C (50/60 Hz) 00 V, 0 V, 00 V, 0 V llowable voltage fluctuation ±0% of rated voltage * Power consumption [W] C 0.35 W (With indicator light: 0.58 W) 00 V 0.78 (With indicator light: 0.87) pparent power [V] C 0 V [5 V] 0 V [30 V] Surge voltage suppressor Indicator light Enclosure 0.86 (With indicator light: 0.97) [0.94 (With indicator light:.07)] 00 V.5 (With indicator light:.30).7 (With indicator light:.46) [.39 (With indicator light:.60)] LE (Neon bulb: C voltage with IN terminal, M connector) IEC6059 standard IP65, JIS C090 * In common between 0 VC and 5 VC, and between 0 VC and 30 VC. * For 5 VC and 30 VC, the allowable voltage fluctuation is 5% to +5% of rated voltage. q Rated voltage 00 VC 50/60 Hz 00 VC 50/60 Hz 3 0 VC [5 VC] 50/60 Hz 4 0 VC [30 VC] 50/60 Hz 5 4 VC 6 VC w Electrical entry T Conduit terminal IN terminal (with connector) O IN terminal (without connector) W M connector (4-pin type) V M connector (5-pin type) Note) Note) Only C voltage is available. e Light/surge voltage suppressor Nil None S With surge voltage suppressor Z With light/surge voltage suppressor Note) Refer to the table () on page 5 for combinations with electrical entry. * OS, OZ are not available. * For C voltage, only O is available for Nil..8 W Type Electrical entry: IN terminal VO307 Y 5 O Z Q Pilot Solenoid Valve Specifications Pilot solenoid valve VO307(Y)- -Q Electrical entry IN terminal, M connector rated C V, 4 V voltage [V] C (50/60 Hz) 00 V, 0 V, 00 V, 0 V llowable voltage fluctuation 5% to 0% of rated voltage Power consumption [W] C.8 W (With indicator light: W) pparent power [V] Light/surge voltage suppressor Enclosure C Inrush.7 V (50 Hz), 0.7 V (60 Hz) Holding 7.6 V (50 Hz), 5.4 V (60 Hz) C iode, LE C (50/60 Hz), LE ustproof VO307 q Y q w 5 w Z e e Electrical entry: M connector q Voltage Nil C Y C W r w Rated voltage 00 VC 50/60 Hz 00 VC 50/60 Hz 3 0 VC 50/60 Hz 4 0 VC 50/60 Hz 5 4 VC 6 VC X35 Q e Light/surge voltage suppressor Nil None Z With light/surge voltage suppressor Note) Refer to the table () on page 5 for combinations with electrical entry. r Electrical entry W M connector (4-pin type) V M connector (5-pin type) Note) Note) Only C voltage is available. 7

9 Coolant Valve Series SC Construction Series SC, 3, 4, 5 i w u N.C o i w N.O. o y e t r q port PE port y u e t r port PE port q Series SC6, 7 i i w N.C. w N.O. u u y y e e r r q q Component Parts No. escription Material Note Body assembly Cast iron Plated Cover assembly luminum die-casted White 3 Plate assembly Iron Seal material (NBR, FKM), Plated 4 Valve body Stainless steel 5 Valve cover NBR, FKM 6 Piston assembly Stainless steel, luminum 7 Return spring Stainless steel, Piano wire 8 Pilot solenoid valve 9 Filter Copper 8

10 Q E Series SC imensions ir operated Series SC, 3, 4 N Pilot port (Back side PE: Filter standard installation) J I.3 Bracket 4 x øk Pilot port Pilot EXH port (Filter standard installation) PE R F E F L M C B Main port ( locations) H Model Main port Pilot port B C E F H I J K L M N SC - 0 3/8 / SC - 5 / / SC3-0 3/4 / SC4-5 / Series SC5, 6, 7 C B Main port ( locations) H Model Main port Pilot port B C E F H Q R SC5-3 /4 / SC6-40 / / SC7-50 /

11 Coolant Valve Series SC imensions External pilot solenoid: 0.35 W type (Pilot valve V6) (Conduit terminal) Series SC, 3, 4 N Manual override Pilot port (Back side PE: Filter standard installation) J P I.3 Bracket O E F 4 x øk L M C B Main port ( locations) H Model Main port Pilot port B C E F H I J K L M N O P SC - 0 3/8 / SC - 5 / / SC3-0 3/4 / SC4-5 / Series SC5, 6, 7 P Pilot port Pilot EXH port (Filter standard installation) PE R Q E O F C B Main port ( locations) H Model Main port Pilot port B C E F H O P Q R SC5-3 /4 / SC6-40 / / SC7-50 /

12 Series SC imensions External pilot solenoid: 0.35 W type (Pilot valve V6) (IN terminal, M connector) Series SC, 3, 4 N Pilot port (Back side PE: Filter standard installation) J PP I IN terminal PP M connector Manual override.3 Bracket O E F 4 x øk L M Cable for M connector (See page 3 for Options.) C B Main port ( locations) H Model Main port Pilot port B C E F H I J K L M N O PP SC - 0 3/8 / SC - 5 / / SC3-0 3/4 / SC4-5 / Series SC5, 6, 7 PP IN terminal M connector PP Pilot port Pilot EXH port (Filter standard installation) PE R Cable for M connector (See page 3 for Options.) Q E O F C B Main port ( locations) H Model Main port Pilot port B C E F H O PP Q R SC5-3 /4 / SC6-40 / / SC7-50 /

13 O S Coolant Valve Series SC imensions External pilot solenoid:.8 W type (Pilot valve VO307) (IN terminal, M connector) Series SC5, 6, 7 M connector IN terminal Cable for M connector (See page 3 for Options.) Pilot port Pilot EXH port (Filter standard installation) Manual override (Non-locking) PE R E Q F C B Main port ( locations) H Model Main port Pilot port B C E F H O Q R S SC5-3H /4 / SC6-40H / / SC7-50H /

14 Series SC How to Fix an uto Switch Series SC, 3, 4 Series SC, 3, 4 Watchmaker s screwdriver Slotted set screw When tightening an auto switch mounting screw, use a watchmaker s screwdriver with a handle of approximately 5 to 6 mm in diameter. Furthermore, use a tightening torque of approximately 0.05 to 0.5 N m. Options Lock ring C: Nickel plated C: Orange uto Switch Proper Mounting Position Cable for M connector (Female connector with cable) V Specifications For C 4-pin type For C 5-pin type 3 For C * When selecting the 5-pin type, only C voltage is available. Cable length [L] [mm] [mm] [mm] B Model SC() -05 0, 5 SC() -0 0, 5 SC() -6 0, 5 SC() SC()3-0 0 SC()3-6 0 SC() SC()4-0 5 SC() M9 5 B 5 6 B 5 7 B 5 4 B 4 6 B 4 7 B 4 3 B 3 6 B 3 7 B 3 [mm] * The above dimensions including a mounted auto switch are for reference only. Confirm that the auto switch works appropriately. ø4.5 ø L 45 4-pin type 5-pin type 4 Socket pin connector pin arrangement Socket pin connector pin arrangement 4 How to Order Include the part number of the female connector with cable together with the part number for the solenoid valve. Example) For lead wire length, 000 mm Terminal no. 3 4 Connections Cable colors Cable cover colors for core wire BROWN: rounding WHITE: Not used BLUE: Power supply for valve BLCK: Power supply for valve Terminal no Connections Cable colors Cable cover colors for core wire BLCK: Power supply for valve BLUE: Power supply for valve RY: rounding WHITE: Not used WHITE: Not used For C SC-050Y-5WZ V For C SC-050Y-WZ V Note) For the valve polarity, refer to Pin assignment of M connector on valve side on page 9. 3

15 Solid State uto Switch irect Mounting Style -M9N/-M9P/-M9B rommet P -wire load current is reduced (.5 to 40 m). P Flexibility is.5 times greater than the conventional model (SMC comparison). P Using flexible cable as stan dard. Precautions Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. Prior to Use For details about uto Switch Connection and Example, refer to Handling Precautions for SMC Products on SMC website. uto Switch Specifications Oilproof Heavy-duty Lead Wire Specifications Refer to SMC website for the details about products conforming to the international standards. PLC: Programmable Logic Controller -M9l (With indicator light) uto switch model -M9N -M9P -M9B Electrical entry In-line In-line In-line Wiring type 3-wire -wire Output type NPN PNP pplicable load IC circuit, Relay, PLC 4 VC relay, PLC Power supply voltage 5,, 4 VC (4.5 to 8 V) Current consumption 0 m or less Load voltage 8 VC or less 4 VC (0 to 8 VC) Load current 40 m or less.5 to 40 m Internal voltage drop 0.8 V or less at 0 m ( V or less at 40 m) 4 V or less Leakage current 00 m or less at 4 VC 0.8 m or less Indicator light Standards Red LE lights up when turned ON. CE marking, RoHS uto switch model -M9N -M9P -M9B Sheath Outside diameter [mm].7 x 3. (ellipse) Insulator Conductor Number of cores 3 cores (Brown/Blue/Black) Outside diameter [mm] ø0.9 Effective area [mm ] 0.5 Strand diameter [mm] ø0.05 Minimum bending radius [mm] (Reference value) 0 cores (Brown/Blue) Note ) Refer to the Best Pneumatics No. catalog for solid state auto switch common specifications. Note ) Refer to the Best Pneumatics No. catalog for lead wire lengths. Lead Wire Length Lead wire length indication (Example) -M9 L Lead wire length Nil 0.5 m M m L 3 m 5 m Z Note) Note) Lead wire length of 5 m (Z) is manufactured upon receipt of order as standard for all applicable auto switches. Weight imensions -M9l uto switch model -M9N -M9P -M9B 0.5 m (Nil) 8 7 Lead wire length.6 m (M) m (L) m (Z) M.5 x 4 L Slotted set screw Indicator light [g] [mm] Most sensitive position 4

16 Water Resistant -Color Indication Solid State uto Switch: irect Mounting Style -M9N/-M9P/-M9B rommet P Water (coolant) resistant type P -wire load current is reduced (.5 to 40 m). P The optimum operating position can be determined by the color of the light. (Red reen Red) P Using flexible cable as standard. Precautions Fix the auto switch with the existing screw installed on the auto switch body. The auto switch may be damaged if a screw other than the one supplied is used. Please consult with SMC if using coolant liquid other than water based solution. Prior to Use For details about uto Switch Connection and Example, refer to Handling Precautions for SMC Products on SMC website. Lead Wire Length Lead wire length indication uto Switch Specifications Weight PLC: Programmable Logic Controller -M9m (With indicator light) uto switch model -M9N -M9P -M9B Electrical entry In-line In-line In-line Wiring type 3-wire -wire Output type NPN PNP pplicable load IC circuit, Relay, PLC 4 VC relay, PLC Power supply voltage 5,, 4 VC (4.5 to 8 V) Current consumption 0 m or less Load voltage 8 VC or less 4 VC (0 to 8 VC) Load current 40 m or less.5 to 40 m Internal voltage drop 0.8 V or less at 0 m ( V or less at 40 m) 4 V or less Leakage current 00 m or less at 4 VC 0.8 m or less Indicator light Standards Oilproof Flexible Heavy-duty Lead Wire Specifications uto switch model -M9N -M9P -M9B Sheath Outside diameter [mm].7 x 3. (ellipse) Insulator Conductor Number of cores Operating position Red LE lights up. Optimum operating position reen LE lights up. CE marking, RoHS 3 cores (Brown/Blue/Black) Outside diameter [mm] ø0.9 Effective area [mm ] 0.5 Strand diameter [mm] ø0.05 Minimum bending radius [mm] (Reference value) 0 cores (Brown/Blue) Note ) Refer to the Best Pneumatics No. catalog for solid state auto switch common specifications. Note ) Refer to the Best Pneumatics No. catalog for lead wire lengths. uto switch model -M9N -M9P -M9B 0.5 m (Nil) 8 7 Lead wire length m (M) m (L) m (Z) [g] (Example) -M9 L imensions [mm] Lead wire length Nil 0.5 m M Note ) m L 3 m Z Note ) 5 m -M9m M.5 x 4L Slotted set screw Indicator light 4 SMC Note ) Lead wire length of 5 m (Z) is manufactured upon receipt of order as standard for all applicable auto switches. Note ) Lead wire length of m (M) is only available for the -M9. For the -M9, it will be made upon request Most sensitive position

17 Series SC Made to Order (Series SC, 3, 4) Please contact SMC for detailed dimensions, specifications and lead times. Pilot Valve: SF4 Symbol -X Power consumption:.8 W SC 05 0 T Z B L S X q w e r t y u i o!0!!!3!4!5 u Pilot valve Equivalent to the standard models except for u, i,!. See pages 5 and 6. i Rated voltage Nil SF4 00 VC 50/60 Hz 00 VC 50/60 Hz 3 0 VC 50/60 Hz 4 0 VC 50/60 Hz 5 4 VC 6 VC 7 40 VC 50/60 Hz 9 Others! Manual override Nil Push type B Slotted locking type Pilot valve: SF4 Pilot Solenoid Valve Specifications How to Order Pilot Valve Pilot solenoid valve Electrical entry rated voltage [V] imensions C llowable voltage fluctuation C (50/60 Hz) P SF4-lll-50-X40 Conduit terminal, IN terminal, M connector 4 V, Other (Option) 00 V, 00 V, Other (Option) 5 to 0% of rated voltage Power consumption [W] C.8 W (With indicator light: W) pparent power [V] C Light/surge voltage suppressor Inrush Holding C C 5.6 V (50 Hz) 5.0 V (60 Hz) 3.4 V (50 Hz).3 V (60 Hz) ZNR (), LE (Neon bulb for 00 V or more) ZNR (), Neon bulb (LE for less than 00 V) SF4 5 T Z 50 X40 q Rated voltage 00 VC 50/60 Hz 00 VC 50/60 Hz 3 0 VC 50/60 Hz 4 0 VC 50/60 Hz 5 4 VC 6 VC 7 40 VC 50/60 Hz 9 Others Equivalent to the standard models except the dimensions given in the diagram. PP q w e r e Light/surge voltage suppressor w Electrical entry Conduit terminal IN terminal M connector Nil S Z None With surge voltage suppressor With light/surge voltage suppressor * TS, OS, OZ are not available. T Conduit terminal IN terminal (with connector) O IN terminal (without connector) W M connector (4-pin type) V M connector (5-pin type) Note) Note) Only C voltage is available. r Manual override Nil B Push type Slotted locking type PP O O O Model Main port O P SClll-ll0 3/ SClll-ll5 / SC3lll-ll0 3/ SC4lll-ll Model Main port O PP SClll-ll0 3/ SClll-ll5 / SC3lll-ll0 3/ SC4lll-ll Model Main port O PP SClll-ll0 3/ SClll-ll5 / SC3lll-ll0 3/ SC4lll-ll

18 Series SC Specific Product Precautions Be sure to read this before handling. Refer to the back cover for Safety Instructions. For Port Solenoid Valves for Fluid Control Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, esign Warning Extended periods of continuous energization If a valve is continuously energized for long periods, heat generation of the coil may result in reduced performance and shorter service life. This may also have an adverse effect on the peripheral equipment in proximity. Should a valve be continuously energized for long periods, or its daily energized state exceeds its non energized state, please use an energy saving type valve with C voltage. dditionally, when using with C voltage, energizing for long periods of time continuously, select the air-operated valve and use the continuous duty type of the VT307 for a pilot valve. Fluid Quality Warning lthough the product has a scraper to prevent foreign matter from entering into the product, fluid containing fine foreign matter such as abrasive powder may cause sealing failure by the foreign matter adhering to the rod sliding part. Perform periodic maintenance or take countermeasures. Sealing failure of the rod sliding surface will allow reverse flow of the fluid in the pilot air piping, entering into the pilot valve or circuit connected to the pilot air piping, causing adverse effects such as operation failure or leakage. Mounting Warning. o not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts.. o not warm the coil assembly with a heat insulator etc. Use tape, heaters, etc., for freeze prevention on the piping and body only. They can cause the coil to burn out. 3. void sources of vibration, or adjust the arm from the body to the minimum length so that resonance will not occur. 4. When mounted in the vertical downward direction, foreign matter can remain in the plate assembly part if there is foreign matter in the coolant. For this reason, avoid mounting in the vertical downward direction as much as possible. Manual Override Warning Since connected equipment will be actuated when the manual override is operated, first confirm that conditions are safe. Non-locking push type Press in the direction of the arrow. Push-turn locking slotted type [ type] While pressing, turn in the direction of the arrow (90 clockwise). If it is not turned, it can be operated the same way as the non-locking type. 7 Manual Override When operating the locking type with a screwdriver, turn it gently using a flat blade watchmaker s screwdriver. [Torque: Less than 0. N m] When locking the manual override on the push-turn locking type (), be sure to push it down before turning. Turning without first pushing it down can cause damage to the manual override and trouble such as air leakage etc. Wiring. pplied voltage When electric power is connected to a solenoid valve, be careful to apply the proper voltage. Improper voltage may cause a malfunction or coil damage.. Check the connections. fter completing the wiring, confirm that the connections are correct. Leakage Voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching element because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows. Power supply Switching element C OFF R Leakage current C coil 3% or less of rated voltage. Leakage voltage SOL. C coil 8% or less of rated voltage. (For 0.35 W type: Pilot valve V6) 5% or less of rated voltage. (For.8 W type: Pilot valve VO307) Operating Environment Products with IP65 enclosures (based on IEC6059) are protected against dust and water, however, these prod ucts cannot be used in water. Maintenance Warning o not disassemble the product. Products which have been disassembled cannot be guaranteed. Especially, do not remove the type C retaining ring in the cover of NC valve. Piston or spring will jump out and might cause injury.

19 Series SC Specific Product Precautions Be sure to read this before handling. Refer to the back cover for Safety Instructions. For Port Solenoid Valves for Fluid Control Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, Precautions on 0.35 W Type [Pilot Valve V6] <For C> Conduit terminal (Non-polar type) With surge voltage suppressor (TS) COM (+, ) Light/Surge Voltage Suppressor <For C> Conduit terminal With surge voltage suppressor (TS) SOL.a (, +) With light/surge voltage suppressor (TZ) COM (+, ) With light/surge voltage suppressor (TZ) LE SOL.a (, +) LE IN terminal (Non-polar type) IN terminal With surge voltage suppressor (S) With surge voltage suppressor (S) COM (+, ) SOL.a (, +) Built-in connector Built-in connector With light/surge voltage suppressor (Z) COM (+, ) With light/surge voltage suppressor (Z) NL SOL.a (, +) LE Built-in connector Built-in connector NL: Neon bulb M connector (Non-polar type) With surge voltage suppressor (WS/VS) COM (+, ) M connector With surge voltage suppressor (WS) SOL.a (, +) Built-in connector Built-in connector With light/surge voltage suppressor (WZ/VZ) COM (+, ) With light/surge voltage suppressor (WZ) NL SOL.a (, +) LE Built-in connector Built-in connector NL: Neon bulb 8

20 Series SC Specific Product Precautions 3 Be sure to read this before handling. Refer to the back cover for Safety Instructions. For Port Solenoid Valves for Fluid Control Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, Key. M connector types of the pilot valve V6 have an IP65 (enclosure) rating, offering protection from dust and water. However please note: these products are not intended for use in water.. o not use a tool to mount the connector, as this may cause damage. Only tighten by hand. (0.4 to 0.6 N m) 3. The excessive stress on the cable connector will not be able to satisfy the IP65 rating. Please use caution and do not apply a stress of 30 N or greater. Please note that if a connector other than the one stated above is used or if the connector is not tightened enough, the IP65 standards will not be satisfied. M connector M Connector 3 Key Female connector with cable Note) For connecting a female connector with cable, adjust the connector key to the M connector key in the valve side since there is an orientation. Be careful not to squeeze it in the wrong direction, as problems such as pin damage may occur. Connection. Loosen the holding screw and remove the cover from the terminal block.. Loosen the screw in the terminal block. Insert the lead core wires or crimped terminals to the terminals, and secure the wires by re-tightening the terminal screw. 3. Secure the cord by fastening the ground nut. Compatible cable Cord O..: ø4.5 to ø7 (Reference) 0.5 to.5 mm, -core or 3-core, equivalent to JIS C 3306 pplicable crimped terminals O-terminals: Equivalent to R.5-3 defined in the JIS C805 Y-terminals: Equivalent to.5-3 manufactured by J.S.T. Mfg. Co., Ltd. Set screw Tightening torque 0.9 to 0.35 N m How to Use Conduit Terminal When making connections, please note that using other than the supported size (ø4.5 to ø7) heavy-duty cord will not satisfy IP65 (enclosure) standards. lso, be sure to tighten the ground nut and holding screw within their specified torque ranges. Washer round nut Tightening torque.5 to 3.75 N m Pin assignment of M connector on valve side (Not used) 4-pin type Key (rounding) (Not used) 5-pin type Key (Not used) Terminal block cover Terminal screw (3 locations) Tightening torque 0.5 to 0.6 N m rommet (Rubber) 3 (Power supply) 4 (Power supply) 3 (Power supply) 4 (Power supply) 5 (rounding) Note) bout C specifications 0.35 W type (Pilot valve V6) has no polarity..8 W type (Pilot valve V0307) has the polarity, pin no. 3 ( ) and pin no. 4 (+). 9

21 Series SC Specific Product Precautions 4 Be sure to read this before handling. Refer to the back cover for Safety Instructions. For Port Solenoid Valves for Fluid Control Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, Connection. Loosen the holding screw and pull the connector out of the solenoid valve terminal block.. fter removing the holding screw, insert a flat blade screwdriver, etc. into the notch on the bottom of the terminal block and pry it open, separating the terminal block and the housing. 3. Loosen the screw (slotted screws) in the terminal block. Insert the lead core wires or crimped terminals to the terminals according to the connection method, and secure the wires by re-tightening the terminal screw. 4. Secure the cord by fastening the ground nut. When making connections, please note that using other than the supported size (ø4.5 to ø7) heavy-duty cord will not satisfy IP65 (enclosure) standards. lso, be sure to tighten the ground nut and holding screw within their specified torque ranges. Changing the entry direction fter separating the terminal block and housing, the cord entry can be changed by attaching the housing in the opposite direction 80. * Be careful not to damage the element etc. with the cord s lead wires. Plug in and pull out the connector vertically without tilting to one side. Precautions on 0.35 W Type [Pilot Valve V6] How to Use IN Terminal IN Connector Part No. Without light Only C voltage V00-6- With Surge Voltage Suppressor Rated voltage Voltage symbol Part no. 4 VC C 4 VS V VC C VS V VC 00/0 VS V VC 00/0 VS V VC 00/0 VS V VC 00/0 VS V VC 40 VS V With Light/Surge Voltage Suppressor Rated voltage Voltage symbol Part no. 4 VC C 4 VZ V VC C VZ V VC 00/0 VZ V VC 00/0 VZ V VC 00/0 VZ V VC 00/0 VZ V VC 40 VZ V When C voltage without IN terminal (O) is selected, always use a IN connector with surge voltage suppressor as the connector. Compatible cable Cord O..: ø4.5 to ø7 (Reference) 0.5 to.5 mm, -core or 3-core, equivalent to JIS C 3306 pplicable crimped terminals O-terminals: Equivalent to R.5-4M defined in the JIS C805 Y-terminals: Equivalent to.5-3l manufactured by J.S.T. Mfg. Co., Ltd. Rod-terminals: Up to size.5 round nut Tightening torque.5 to 3.75 N m Washer rommet (Rubber) (Voltage symbol) Refer to the table of IN connector part no. below. Set screw Tightening torque 0.5 to 0.6 N m (Position for light mounting) Terminal block Terminal screw (3 locations) Tightening torque 0.4 to 0.5 N m Circuit iagram with Light/Surge Voltage Suppressor C circuit diagram NL V R NL: Neon bulb, R: Resistor V: Response C circuit diagram V LE LE: Emitting diode, R: Resistor V: Pilot valve V6 is a low power consumption type. The response is slower than the VNC series. If the response time is a problem, use products below. SC00/300/400: Made to Order (Part number suffix -X ) See page 6. SC500/600/700: Installed pilot valve VO307 (.8 W type) See page 5. R 0

22 Series SC Specific Product Precautions 5 Be sure to read this before handling. Refer to the back cover for Safety Instructions. For Port Solenoid Valves for Fluid Control Precautions, refer to Handling Precautions for SMC Products and the Operation Manual on SMC website, Precautions on.8 W Type [Pilot Valve VO307] isassembly How to Use IN Terminal ) Loosen screw q and pull up housing w in the direction of screw q to remove the connector from the body (solenoid). ) Pull out screw q from housing w. 3) On the bottom part of terminal block e, there is a notch o. If a small flat blade screwdriver is inserted into the gap between housing w and terminal block e, terminal block e will be removed from housing w. (Refer to the figure below.) 4) Remove cable gland r, washer t and rubber seal y. Wiring ) Insert cable gland r, washer t and rubber seal y into cable u in order, and insert it into housing w. ) Loosen screws! on terminal block e. Insert lead wires!0 and tighten screws! again. Note ) The tightening torque should be 0.5 N m ±5%. Note ) The applicable outside diameter of cable u is ø6 to ø8 mm. Note 3) Round or Y-shaped crimped terminal cannot be used. ssembly ) Insert cable gland r, washer t and rubber seal y and housing w into cable u in order. Connect cable u to terminal block e and fix terminal block e to housing w in place. Insert the terminal block until it makes a click sound. ) Insert rubber seal y and washer t into the cable entry on housing w in order, and tighten cable gland r securely. 3) Insert gasket i into the gap between the bottom of terminal block e and plug on the equipment, and insert screw q from the top of housing w to tighten them. Note ) The tightening torque should be 0.5 N m ±0%. Note ) The orientation of the connector can be changed by 80 degrees depending on the mounting direction of housing w and terminal block e. IN Terminal Connector escription IN connector Part no. M09NJ-B7 (CE-compliant) C C Light/Surge Voltage Suppressor Electrical Wiring The IN connector terminal and conduit terminal (with indicator light/surge voltage suppressor) are wired internally as shown below. Connect each terminal to the corresponding wire of the power supply. pplicable cord O.. type: ø6 to ø8 Lead Wire Color Voltage Color 00 VC Blue 00 VC Red C Red (+), Black ( ) Other Terminal no. Terminal no. Terminal no. (+) Terminal no. ( ) IN terminal block ray Indicator light assembly Indicator light assembly round Terminal no. IN terminal + q w e y t r i o!!0 u

23 Safety Instructions : Warning: anger : indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. Warning indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. anger indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of, Warning or anger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) ), and other safety regulations. ) ISO 444: Pneumatic fluid power eneral rules relating to systems. ISO 443: Hydraulic fluid power eneral rules relating to systems. IEC 6004-: Safety of machinery Electrical equipment of machines. (Part : eneral requirements) ISO 08-: Manipulating industrial robots Safety. etc. Warning. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. o not service or attempt to remove product and machinery/ equipment until safety is confirmed.. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed.. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight.. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. n application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. Compliance Requirements. The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and isclaimer/ Compliance Requirements The product used is subject to the following Limited warranty and isclaimer and Compliance Requirements. Read and accept them before using the product. Limited warranty and isclaimer. The warranty period of the product is year in service or.5 years after the product is delivered, whichever is first. ) lso, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch.. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. ) Vacuum pads are excluded from this year warranty. vacuum pad is a consumable part, so it is warranted for a year after it is delivered. lso, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty.. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WM) or any other weapon is strictly prohibited.. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. SMC products are not intended for use as instruments for legal metrology. Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country. Revision history Edition B Series SC5, 6, 7 added. Number of pages decreased from 8 to 4. TU Safety Instructions Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.

1 1/4 (32A) to 2 (50A) added.

1 1/4 (32A) to 2 (50A) added. Coolant Valve 0.5 MPa.0 MPa.6 MPa RoHS /4 (3) to (50) added. Flow rate Cv (For 0.5 MPa specification) 3 4 5 0 0 30 Cv (kv) 40 5 million cycles or more Port size 70 6.5 (5.6) 3/8 (0), / (5).8 (0.) 3/4 (0)

More information

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption Port Solenoid Valve Direct Operated Poppet Type Power consumption Vacuum applications New [Option] RoHS 4 Standard wtype (Existing product: 4.8 W) 0. kpa Energy-saving type.8 w (Existing product: W) A

More information

Coolant Valve SGC2 :155 SGC3 :284 SGC4 :440. million cycles or more. Service life: 5 million cycles or more 5 Service life: million cycles or more

Coolant Valve SGC2 :155 SGC3 :284 SGC4 :440. million cycles or more. Service life: 5 million cycles or more 5 Service life: million cycles or more Flow rate v factor (in case of 0.5 MPa specification) specification) SC :55 SC :8 SC :0 Coolant Valve Series SC For 0.5 MPa/.0 MPa/.6 MPa million cycles or more (based on SMC s test condition) (based on

More information

Coolant valve. SGC/SGH Series

Coolant valve. SGC/SGH Series Doc. no. PRODUCT NAME Coolant valve MODEL / Series / Product Number SGC/SGH Series Contents Safety Instructions ------------------------------------------------------------------------------------- 2,3

More information

Low Torque Metal Seal Type Rotary Joint. MQR Series

Low Torque Metal Seal Type Rotary Joint. MQR Series Doc. No MQR****-OML0002-A. PRODUCT NAME Low Torque Metal Seal Type Rotary Joint MODEL / Series / Product Number MQR Series Contents 1. Contents P1 2. Model / Specifications P2~5 3. Safety Instructions

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1 No.EX -OME0016-A PRODUCT NAME SI unit MODEL / Series / Product Number EX140-SDN1 Table of Contents 1. Safety instructions 2 2. Specifications 7 2-1. General specifications 7 2-2. Electrical ant network

More information

High Pressure Coolant Valve

High Pressure Coolant Valve High Pressure Coolant Valve Series.5 MPa, 7.0 MPa Corresponding to high speed grinding and long drilling processes Coolant valve for high pressure coolant liquid (up to.5 MPa or 7.0 MPa) that is ideal

More information

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number Doc. no. Coolant valve PRODUCT NAME VNC/VNH Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions

More information

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g. Speed Controller with One-touch Fittings In-line In-line Type y Easo t use RoHS Brass Stainless steel Reduces flow setting time! Push-lock type Knob O.D.: Almost doubled! Easy to lock ΓΈ9.4 Unlock ΓΈ5 Lock

More information

Exclusively for air pressure system and air-hydro circuit control

Exclusively for air pressure system and air-hydro circuit control Process Valve Series Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external

More information

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control

2 Port Valve For Compressed Air and Air-hydro Circuit Control. Exclusively for air pressure system and air-hydro circuit control Process Valve Port Valve For Compressed ir and ir-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Valve [Option] Cylinder actuation by external pilot

More information

3 Port 3 Position Valve

3 Port 3 Position Valve Port Position Valve Pilot Solenoid ir Operated ohs Intermediate stopping of cylinders * up to ΓΈ15 is possible. Pilot solenoid Manifold ir operated * For VEX 4, 00 mm/s, horizontal movement Power consumption:

More information

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number Doc. no. Process valve PRODUCT NAME VNA Series MODEL / Series / Product Number Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Design

More information

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions. Clean Exhaust Filter This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO14644-1) (* Based on SMC s measuring conditions.) Air can be directly exhausted in a clean room

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry ir VQ0/30 Series Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 Series VCH VDW SX0

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. T Body ported O Manifold. Valve option 3 Port Solenoid Valve Direct Operated Poppet Type VT317 Series Rubber Seal [Option] Note) CE-compliant: Electrical entry is applicable only for the DIN terminal. Compact yet provides a large flow capacity

More information

Coolant Valve. VNC Series. Cylinder actuation by pilot air

Coolant Valve. VNC Series. Cylinder actuation by pilot air oolant VN Series ir Operated/xternal Pilot Solenoid [Option] ylinder actuation by pilot air Wide selection of port and variations Threaded type (6 to ) lange type (3 to 80) Low water hammer or details,

More information

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating

More information

Pressure Relief 3 Port Valve With Locking Holes

Pressure Relief 3 Port Valve With Locking Holes Doc. No. VH*-OMQ0023-B PRODUCT NAME Pressure Relief 3 Port Valve With Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~02A,B(-B,S)(-K,R,Z) VHS30-(F,N)02~03A,B(-B,S)(-K,R,Z) VHS40-(F,N)02~04A,B(-B,S)(-K,R,Z)

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. N.C. N.C. X (P) N.O. N.O. X (P) Series VP 3 port Function plate makes it possible to

More information

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions Port Solenoid Valve VT07 Series Direct Operated Poppet Type Power consumption 4 Standard wtype (Current product: 4.8 W) Energy-saving type.8 w (Current product: 2 W) Vacuum applications 0.2 kpa [Option]

More information

High Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC

High Vacuum Solenoid Valve. 25% reduction. Max. Weight. 18% * lighter. Max. * XSA2-2 AC 100 V, 200 V, 110 V, 220 V, 240 V, 48 V, 24 V, 230 V DC Normal lose High Vacuum Solenoid Valve Minimum operating pressure * 1x10 6 Pa(abs) * OUT side Leakage Internal 1.3 x10 9 Pa m3/s Note) Note) Except grommet/ RoHS External 1.3 x10 11 Pa m3/s 2 types of

More information

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series Doc. No. High Vacuum Solenoid Valve PRODUCT NAME XSA Series MODEL/ Series Thank you for purchasing this SMC product. Be sure to read this Operation Manual carefully and understand its contents before operating

More information

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS Rubber Seal 3 Port Solenoid Valve Series VKF300 Direct Operated Poppet Type Compact yet provides a large flow capacity Body width 18 mm Various manifold piping directions Output port: Manifold set-up allowing

More information

Soft Start-up Valve. AV2000/3000/4000/5000 Series

Soft Start-up Valve. AV2000/3000/4000/5000 Series Soft Start-up Valve V000/000/000/000 Series [Option] C- R- W- C R - W - Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off

More information

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C

1.3 x % reduction 18% High Vacuum Solenoid Valve. XSA Series CAT.ES140-7B. 5 to 60 C Normal lose igh Vacuum Solenoid Valve Minimum operating pressure x0 * 6 Pa(abs) * OUT side * * Excluding grommet/ RoS Leakage Internal.3 x0 9 Pa m3/s External.3 x0 Pa m3/s Max. Max. Power consumption 5%

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal 3 ort Solenoid Valve Series SYJ300/00/700 SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M. V3 Cover

More information

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve: 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Valve: Port Valve For Compressed ir and ir-hydro Circuit Control Series VN Style VN -6 VN -8 8 VN - 3 8 VN - 5 VN -5 VN3-0 3 0 Note) This product cannot be used for water application. JIS Symbol

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Coolant Valve. Air Operated/External Pilot Solenoid

Coolant Valve. Air Operated/External Pilot Solenoid Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) lange type (3 to ) Low water hammer or details, refer to page

More information

49.5 mm Overall. 30 mm MXZ ΓΈ20. Compact. Compact Cylinder with Linear Guide. MXZ Series CAT.ES20-236A. ΓΈ12, ΓΈ16, ΓΈ20, ΓΈ25. MXZ ΓΈ20, 10 mm stroke.

49.5 mm Overall. 30 mm MXZ ΓΈ20. Compact. Compact Cylinder with Linear Guide. MXZ Series CAT.ES20-236A. ΓΈ12, ΓΈ16, ΓΈ20, ΓΈ25. MXZ ΓΈ20, 10 mm stroke. Compact Cylinder with Linear Guide ΓΈ12, ΓΈ16, ΓΈ20, ΓΈ25 RoHS Compact 49.5 mm Overall length MXZ ΓΈ20, 10 mm stroke 30 mm MXZ ΓΈ20 Width Design and assembly time is reduced due to integration of a linear guide

More information

AV2000-A/3000-A/4000-A/5000-A

AV2000-A/3000-A/4000-A/5000-A Soft Start-up Valve Start-up valve for low speed air supply to gradually raise initial pressure in an air system and for quick exhaust by cutting off air supply Power consumption: 0.35 W * At 12/24 VDC

More information

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W)

3 million cycles. High Pressure Coolant Valve. SGH Series W (24 VDC) (With light/surge voltage suppressor: 0.58 W) igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ΓΈ16, 10 mm stroke) Weight

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ΓΈ16, 10 mm stroke) Weight Compact Guide Cylinder ΓΈ12, ΓΈ16, ΓΈ20, ΓΈ25, ΓΈ32, ΓΈ40, ΓΈ50, ΓΈ63, ΓΈ80, ΓΈ100 RoHS Compact Overall length shortened New s ΓΈ80, ΓΈ100 added. Port thread types NPT, G added. Height shortened JMGP ΓΈ32 25 mm stroke

More information

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations

Coolant Valve. Series VNC. Cylinder actuation by pilot air. Wide selection of port size and variations Coolant Valve ir Operated/xternal Pilot Solenoid Cylinder actuation by pilot air Wide selection of port and variations hreaded type (6 to ) type (3 to ) Low water hammer or details, refer to page 07. Large

More information

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch PRODUCT NAME Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch MODEL / Series / Product Number D-P3DW(A) * Series Contents Safety Instructions 2 Model Indication Method 8 Names and

More information

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry Series 0-VQ00 port solenoid valve How to Order Valves 0 VQ 0 F ir cylinder Clean series Series VQ Compact port valve Type of actuation Normally closed Note) Normally open Note) Normally open type is available

More information

Speed Controller with Indicator

Speed Controller with Indicator Speed Controller with Indicator Numerical indication of handle rotation for flow rate reduces flow setting time and setting errors! Indicator window Body size Body size or larger Indicator window Number

More information

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series Doc. No. 3 Port Direct Operated Solenoid Valve PRODUCT NAME VT307 Series MODEL/ Series Contents Safety Instructions ------------------------------------------------------------------------------- 2,3 Precautions

More information

Regulator Valve. VEX1 Series

Regulator Valve. VEX1 Series Doc. no. PRODUCT NAME Regulator Valve MODEL / Series / Product Number VEX1 Series Contents Safety Instructions ---------------------------------------------------------------------------------- 2,3 Precautions

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Series VP3145/3165/3185

Series VP3145/3165/3185 Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes

More information

Solid State Auto Switch D-M9#A#

Solid State Auto Switch D-M9#A# PRODUCT NAME Solid State Auto Switch MODEL / Series / Product Number D-M9#A# Contents Safety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 10 Summary of Product parts 10 Definition

More information

Pilot Operated 2 Port Solenoid Valve for Dry Air

Pilot Operated 2 Port Solenoid Valve for Dry Air Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity VQ0 Mass (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series VQ0 High frequency operation possible

More information

NAMUR Interface 5 Port Solenoid Valve

NAMUR Interface 5 Port Solenoid Valve NAMUR Interface 5 Port Solenoid Valve Series VFN000N 5 5 Specifications Valve Electrical entry Fluid Max. operating pressure Min. operating pressure Ambient and fluid temperature Lubrication Pilot operator

More information

Doc. No.VG300 -OMH0002-B. 3 Port Solenoid Valve PRODUCT NAME. VG342 Series MODEL/ Series

Doc. No.VG300 -OMH0002-B. 3 Port Solenoid Valve PRODUCT NAME. VG342 Series MODEL/ Series Doc. No. 3 Port Solenoid Valve PRODUCT NAME VG342 Series MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions on Design

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve V00 Series Rubber Seal Power consumption 0. W (with power saving circuit) Note) Refer to page 7 for details. temperature rises: C (with power saving circuit) Sonic conductance Series

More information

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector

D-sub connector. Type 60F. Manifold 1 (P: SUP), 3/5 (R: EXH) Valve stations (With power terminal) D-sub connector Series 0-SZ000 Port Solenoid Valve Cassette Type Manifold Series 0-SZ000 / Plug-in Type Model Manifold (P: SUP), / (R: EXH) Valve stations (With power terminal) pplicable connector Internal wiring (),

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Doc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series

Doc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series Doc. Solenoid Valve PRODUCT NAME VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

3 Port Solenoid Valve

3 Port Solenoid Valve 3 ort Solenoid Valve Series VKF300 ubber Seal Direct Operated oppet Type Compact yet provides a large flow capacity Body width 8 mm vailable in vacuum applications ( 0. ka) Can be used in vacuum/release

More information

Direct Operated 3-port solenoid valve

Direct Operated 3-port solenoid valve Doc. No. PRODUCT NAME Direct Operated 3-port solenoid valve MODEL/ Series Series: VT315 Contents Safety Instructions --------------------------------------------------------------------------- 2,3 Precautions

More information

Specifications. Fluid Ambient and fluid temperature ( C)

Specifications. Fluid Ambient and fluid temperature ( C) Series 0-V00 Rubber seal port direct operated solenoid valve Specifications Fluid Ambient and fluid temperature ( C) Note ) Response time (DC) ms Max. operating frequency (Hz) Manual override Lubrication

More information

0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67.

0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67. Actuator Position Sensor Actuator stroke position is output with an analog signal. IP67 Repeatability 0.1 mm (Varies depending on the operating conditions.) Analog output 4 measurement ment ranges Voltage

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range (1) Response time 3 position (2) Enclosure For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Series 000 Compact and lightweight: 3 mm width Compact yet provides

More information

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single

Fluid Internal pilot Operating pressure range (MPa) External pilot Operating pressure range (MPa) 2 position single Valve Manifold Common Specifications Solenoid Valve Specifications Made to Order Specifications (For details, refer to page --08.) JIS Symbol position single solenoid position double solenoid position

More information

High Vacuum L Type Valve

High Vacuum L Type Valve Doc. no. PRODUCT NAME High Vacuum L Type Valve MODEL / Series / Product Number XLFV-2 Series Contents Safety Instructions - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2 1. Product Specific Precautions

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000

D-sub Connector. Cassette base manifold SV1000/SV2000 Tie-rod base manifold SV1000/SV2000/SV3000/SV4000 D-sub Connector J Tie-rod base Cassette base pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000//000 Number of connectors: pins MIL-C-08 Conforming to JIS-X-0 --6 For details

More information

SI unit for AS-Interface EX250-SAS#

SI unit for AS-Interface EX250-SAS# PRODUCT NAME SI unitfor AS-Interface MODEL / Series / Product Number EX250-SAS# Table of Contents Safety Instructions 2 Product Outline 8 Model Indication and How to Order 9 Summary of Product elements

More information

Vacuum / Release Unit

Vacuum / Release Unit Rubber Seal Vacuum / Release Unit Series VQD1000-V Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow

More information

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet

More information

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot 3 Port Solenoid Valve Pilot Operated Poppet Type Series VG342 Rubber Seal [Option] Low power consumption 4.8 W DC (Standard type) 2 W DC (Energy-saving type) No lubrication required Possible to use in

More information

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Vacuum / Release Unit Series VQD1000-V Rubber Seal Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area [Option] Smooth detachment of a work piece without

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option. Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ΓΈ12, ΓΈ16, ΓΈ20, ΓΈ25, ΓΈ32, ΓΈ40, ΓΈ50, ΓΈ63, ΓΈ80, ΓΈ100

45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ΓΈ12, ΓΈ16, ΓΈ20, ΓΈ25, ΓΈ32, ΓΈ40, ΓΈ50, ΓΈ63, ΓΈ80, ΓΈ100 Compact Cylinder ΓΈ12, ΓΈ16, ΓΈ20, ΓΈ25, ΓΈ32, ΓΈ40, ΓΈ50, ΓΈ63, ΓΈ80, ΓΈ100 RoHS Compact Both ends tapped mounting added. New s ΓΈ80, ΓΈ100 added. Port thread types NPT, G added. Overall length shortened 10 mm stroke

More information

5 Port Solenoid Valve

5 Port Solenoid Valve 5 Port Solenoid alve Plug Lead Type RoHS New Body Ported Flow-rate characteristics For single/double solenoid C [dm 3 /(s bar)]: 0.6 Single Unit alve width: 7. mm Possible to drive cylinders: Up to ΓΈ32

More information

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications

How to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector

More information

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4 Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double

More information

Pressure Sensor for General Fluids PSE570/573/574

Pressure Sensor for General Fluids PSE570/573/574 PRODUCT NAME Pressure Sensor for General Fluids MODEL / Series / Product Number PSE570/573/574 Table of Contents Safety Instructions 2 Model Identification and How to Order 8 Names of Parts of Product

More information

Series DV

Series DV Series DV00 3000 4000 5port Pilot Solenoid Valve Quick response time & large flow capacity Response time is less than 1ms (DV00) Increase of CV factor(.5 times larger than conventional valve with the same

More information

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series Doc. No. Solenoid Valve PRODUCT NAME VQ4000/5000 (Pilot Valve V100) MODEL/ Series Contents Safety Instructions ---------------------------------------------------------------------------- 2,3 Precautions

More information

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

Series VFR Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non Table of Contents Series Port Pilot Operated Solenoid ValveRubber Seal... Series Variations... Manifold Variations... Precautions... Series 000 Port Pilot Operated Solenoid ValveRubber Seal, Plug-in/Non

More information

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve 5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion

More information

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa 3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while

More information

Wide Type Parallel Style Air Gripper

Wide Type Parallel Style Air Gripper Wide Type Parallel Style ir Gripper ΓΈ, ΓΈ6, ΓΈ2, ΓΈ25 Weight Max. % reduction 585 g 525 g ΓΈ6, Opening/Closing stroke: 3 mm RoHS Weight reduced by the change of the body shape and internal construction M Dust

More information

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range

5 Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in. Standard Specifications. Fluid Operating pressure range For details about certified products conforming to international standards, visit us at www.smcworld.com. Port Pilot Operated Solenoid Valve Rubber Seal, Plug-in/Non Plug-in Series VFR2 JIS Symbol type

More information

0.35 W (Without light)

0.35 W (Without light) Modular Connection Type Residual Pressure Relief 3 Port Solenoid Valve For connecting to F.R.L. units C25- C30- C40- FORMTION RoHS VP500 VP700 llows for space saving and reduced piping labor. Power consumption:

More information

Digital Flow Switch (Remote type sensor unit)

Digital Flow Switch (Remote type sensor unit) PRODUCT NAME Digital Flow Switch (Remote type sensor unit) MODEL / Series / Product Number PFM5## Table of Contents Safety Instructions 2 Model Indication and How to Order 10 Summary of Product parts 13

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

Digital Gap Checker. ISA3 series

Digital Gap Checker. ISA3 series PRODUCT NAME Digital Gap Checker MODEL / Series / Product Number ISA3 series Table of Contents 1 Before Use Safety Instructions 2 2 About this product Features 7 Model Indication and How to Order 8 Summary

More information

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type) CAT.1101E-S www.sym1.com KV series Innovatively detachable Manifold Block (DIN Rail Mounting) Smart Solenoid Valve (Plug-in type, D-SUB multi-connector ) Compact size with large flow capacity Exceedingly

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

Two Hand Control Valve

Two Hand Control Valve Two Hand Control Valve Series n output is available through synchronized, twohanded operation (within 0.5 s)! Conforming to EN574 RoHS (Interchangeable with XT92-67 ) Example of a basic circuit diagram

More information

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000) 5 Port Pilot Operated Solenoid Valve Rubber Seal Series 1000/3000/5000 Large flow capacity Yet compact size. Low power consumption 1.8 W (DC) Exhausting equipment for pilot valve not required. Common exhaust

More information

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated. Power Valve: Regulator Valve Series Large capacity relief regulator Rapid tank internal pressure setting, air blow, constant pressure supply and driving, balance and driving, steps directional control

More information

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection

10 mm. 7.5 mm. 40 mm. 4 Port Solenoid Valve. Series SJ2000/3000 SJ3000 SJ2000. Cassette Type Manifold. Connecter connection Rubber Seal Port Solenoid Valve Series SJ000/000 Cassette Type Manifold 0 mm 7. mm (SJ000) 0 mm (SJ000) Non plug-in type Individual wiring manifold SJ000 SJ000 Can be mounted together. Connecter connection

More information

Digital Gap Checker. ISA3 series

Digital Gap Checker. ISA3 series PRODUCT NAME Digital Gap Checker MODEL / Series / Product Number ISA3 series Table of Contents 1 Before Use Safety Instructions 2 2 About this product Features 7 Model Indication and How to Order 8 Summary

More information

Mini Free Mount Cylinder

Mini Free Mount Cylinder Mini Free Mount Cylinder Series ΓΈ, ΓΈ, ΓΈ, ΓΈ, ΓΈ, ΓΈ1, ΓΈ Series 1 ction Stroke 1 2 0 0 0 Clean uto switch series None Rod end Male threaded Without thread Solid state switch D-F D-M9 D-M9 W Female threaded

More information

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC Base Mounted Series VQZ00/00/00 VQZ00/00 / How to Order Valve Made to Order (For details, refer to page 9 and 4.) VQZ 5 5 M Series VQZ00 body width 5 mm VQZ00 body width 8 mm Type of actuation 4 N.C. N.O.

More information

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC 5 Port Pilot Operated Solenoid Valve Metal Seal Series S Series Variations Body Ported Base Mounted Series S000 S000 S000 S000 S000 S4000 S5000 Sonic conductance C [dm /s bar)] 4/ 5/(A/B R/R) Single Double.8.4

More information