Pressure Gauge Guide

Size: px
Start display at page:

Download "Pressure Gauge Guide"

Transcription

1 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) Gauge for General Purpose With limit indicator With limit indicator Oil-free/External Parts opper-free Gauge With limit indicator Gauge for lean egulator With limit indicator With limit indicator ø5 ø26 ø37.5 G5 G27 G36 GA36 G6 ø2.5 GA6 ø30 ø3 ø2.5 ø2.5 Vertical side Vertical side G33 Vertical side GA33 G3 G6E G6- - SA, B Gauge with Switch precision ±% FS Gauge for lean Series (0-Series) ø 3 G9 3 precision ±% FS precision ±% FS precision ±% FS 3 precision ±% FS range 0 to.0 0 to.0 0 to.0 0 to.5 0 to.0 0 to.5 0 to to to.0 range 0 to.0 0 to.5 range 0 to.0 range 0 to.0 0 to.5 range M5 (Female ) 6 ase lear cover Stud Zinc die-casted Black graphite Black disulfide molybdenum olled steel Black melamine painted Black disulfide molybdenum olled steel Black melamine painted Stainless steel Zinc die-casted Black graphite Black disulfide molybdenum Black disulfide molybdenum ase lear cover Stud olled steel Black melamine painted Zinc die-casted hrome plated Stainless steel Black melamine painted Glass Polycarbonate Polycarbonate Polycarbonate Polycarbonate Hard Glass olled steel Polycarbonate ø2.5 GP6 3 0 to.0 Black melamine painted Polycarbonate Hard Electroless nickel plated ase lear cover Stud Nickel plated ase lear cover Stud Stainless steel ase lear cover Stud () () () () () Attachment (2) over ring assembly ) Please consult with SM for other scale indication s and connecting NPT. 2) Possible for use in panel mounting. 3) Please contact SM for the pressure range 0 to 0.6 of GA33. Attachment (2) over ring assembly ) Please consult with SM for other scale indication s and connecting NPT. 2) Possible for use in panel mounting. Attachment ) Please consult with SM for other scale indication s and connecting NPT. Attachment over ring assembly ) Please consult with SM for other scale indication s and connecting NPT. 2) Possible for use in panel mounting. Attachment (2) over ring assembly ) Please consult with SM for other scale indication s and connecting NPT. 2) Possible for use in panel mounting.

2 2 Gauge for General Purpose G5, G27 O.D.: ø5 ø26 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G5 G27 G5-0-0 G27-0- Be sure to read the precautions on page --5 for selection and installation. 2 (Width across flats) M5 x 0. x 5 Port size () precision ase lear cover Stud Bourdon tube Applicable model (Standard) (Made to Order) () G5 : M5 (Female ) ±5% F.S. (Full span) G27 Zinc die-casted (Black graphite ) Polycarbonate Zinc die-casted (Black graphite ) AM000/2000 A000, A000, AW000 G5-0-0 G to.0 0 to.0 /, M5 (Female ) 6 ) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction. G27-0-M5-X20 6 Weight (kg) aution on handling: When drain or oil, etc. gets into the gauge, it may result in a malfunction. ) Indicates the condition at the lower pressure limit. Use a pipe tape for sealing. ecommended tightening torque is between 3 and N m for /6 and 7 and 9 N m for /. 2) Water cannot be used as an operating fluid. Because the clearance gap of the air passage of the Bourdon tube is very small. Water will block the gap and cause a malfunction. Similarly, when using other fluids, please consult with SM for fluid compatibility information concerning possible corrosion and response delay, etc. Other versions of this can be made on a made-to-order basis. Please consult with SM for details, as delivery times may be extended. () 0 to.0 M5 (Female ) ) Do not apply more excessive pressure than max. pressure display. It will be a cause of malfunction. G X20 gauge 5 ø5 27 ø26 X20 M5 (Female ) only ) X3 (Wetted parts SUS) specifications are not available. 0 /: M5 (Female ) 2) Part number for pressure gauge /6 with psi s is G27-P - -X30. This will no longer be sold for use in Japan after the Max. display pressure new Weight and Measure Act Unit: has been implemented (October, ). G5 type is not available. other than.0 is not available. F..L. AV AU AF A I VEX AM ITV I VBA VE VY G PPA AL --3

3 3 Gauge for General Purpose /With limit indicator G36, GA36 O.D.: ø37 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G Be sure to read the precautions on page --5 for selection and installation. -- Port size () (Standard) G G36--0 G G GA (Made to Order) precision ase lear cover Stud Weight (kg) Applicable model G X2 G Bourdon tube 0 to.0 0 to.0 0 to.0 0 to.5 G36 GA36 Vertical side ( M: With M5 female ) ±3% F.S. (Full span) (Black disulfide molybdenum coat treated) (Black disulfide molybdenum coat treated) olled steel (Black melamine painted) Polycarbonate (Part no.: G ) A2000/2500/3000 A2000/2500/3000 AW2000/3000 ) When installing a pressure gauge, be careful not to fasten too tight. Excessive tightening will result in damage. Use a pipe tape for sealing. ecommended tightening torque is : Set between 7 and 9 N m. 2) Not applicable to water as fluid because its stub is made from aluminum die-casted. Water may cause corrosion and block the air passage. Use a pressure gauge with wetted parts made from stainless steel, G6- -X3. (: Take care when using G36- -0M, whose wetted part is made from brass. Some corrosion may result.) Design system to not be affected by water hammer when using water as fluid. Similarly, when using other fluids, please consult with SM, to prevent corrosion-related problems. ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. Other versions of this can be made on a made-to-order basis. Please consult with SM for details, as delivery times may be extended. ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G M X2 gauge 36 ø37.5 Vertical side A Max. display pressure Unit: X2 Plated stem (Ni) Nickel plated X Oil-free Wetted parts degrease washing ) X3 (wetted parts SUS) specifications is not available. 2) over ring assembly is not available. 3) Part number for pressure guage with psi s is G 36-P - -X30. This will no longer be sold for use in Japan after the new Weight and Measure Act has been implemented (October, 999). M M5 (Female ) ) Use M5 female when piping onto a panel.

4 G36 GA36 F..L. AV AU AF ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) A I VEX AM ITV I VBA VE VY G PPA AL --5

5 5 Gauge for General Purpose/With limit indicator G6, GA6 O.D.: ø2 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G6-0-02M- Be sure to read the precautions on page --5 for selection and installation. --6 Port size () ) Indicates the condition at the lower pressure limit. Use a pipe tape for sealing. ecommended tightening torque: /: Set between 7 and 9 N m, /: 2 and N m respectively. 2) Not applicable to water as fluid because its stub is made from aluminum die-casting. Water may cause corrosion and block the air passage. Use G6- -X3 pressure gauge with wetted parts SUS (wetted parts of G6- -0M are made of brass and this become lightly corroded. Take precautions when using.) Design system to not be affected by water hammer when using water as fluid. Similarly, when using other fluids, please consult SM for fluid compatibility information concerning corrosive potential. (Standard) G6-2-0/ 02 G6--0/ 02 G6-7-0/ 02, G6-0-0/ 02 0 to.0 G6-2-0 to 02M G6--0 to 02M G6-7-0 to 02M G6-0-0 to 02M GA6-0-0 to 02 0 to.0 0 to.0, M5 (Female ), ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. Other versions of this can be made on a made-to-order basis. Please consult with SM for details, as delivery times may be extended. (Made to Order) precision ase Bourdon tube Weight (kg) A000/5000/5500/6000 Applicable model A000/5000/6000 AW000 Attachment: Part no.: 3050-A With cover ring assembly Part no.: A G6-2-0 to 02-/ G6--0 to 02-/ G6-7-0 to 02-/ G6-0-0 to 02-/ G6-2-0 to 02M-/ G6--0 to 02M-/ G6-7-0 to 02M-/ G6-0-0 to 02M-/ G6--02-X30 G X30 G6-2-02M-X G6--02M-X G6-7-02M-X G6-0-02M-X G6-2-02M-/ -X G6--02M-/ -X G6-7-02M-/ -X G6-0-02M-/ -X G X2 G6-5-0 to 02 lear cover Stud psi 0 to.0 0 to.0 0 to.0 0 to.0 0 to.0 0 to.0 0 to.5 G6 0 to 60 0 to 50 M5 (Female ) With cover ring assembly Oil-free M5 (Female ) Oil-free, With cover ring assembly Plated stem (Ni) ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction., psi GA6 Vertical side /, / ( M: with M5 female ) ±3% F.S. (Full span) (Black disulfide molybdenum ) olled steel (Black melamine painted) Polycarbonate (Part no.: G ) (Black disulfide molybdenum ),,

6 6 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G M X2 A G6 gauge GA6 Vertical side 6 ø Max. display pressure Unit: The dimensions in ( ): onnecting / M5 x 0. x 5 M With M5 (Female ) : Use M5 female when piping onto a panel. Attachment (over ring assembly) Without cover ring assembly lear cover has no protrusion. (lear cover is irremovable.) lear cover has protrusion. (lear cover is removable.) X2 X3 X G6: With cover ring assembly (For panel mount) (lear cover is not removable.) M x 2 3.5(5.5) Stud parts Nickel plated Wetted parts stainless steel () Oil-free For setting method, efer to page --5. Wetted parts degrease washing ) Movable parts (gear, etc) inside pressure gauge are made of brass. 2) Part number for pressure gauge with psi s is G 6-P - -X30. This will no longer be sold for use in Japan after the new Weight and Measure Act has been implemented (October, 999). Panel cut dimensions Plate thickness Max. 3.5t 5 M x 2 (lear cover is removable.) 3.5(5.5) M5 x 0. x 5 M5 x 0. x 5 F..L. AV AU AF A I VEX AM ITV I VBA VE VY G PPA AL --7

7 7 Gauge for General Purpose G33, GA33 O.D.: ø30 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G33 GA33 ø30 / ø30 0 Hex. width across flats ø3 Bleed port (7) 3 G GA / 2 Port size () precision ase lear cover Stud Bourdon tube Applicable model (Standard) G G G to 0.3 G to 0.6 G to.0 GA GA33--0 GA GA to.0 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. (Made to Order) G X2 G X2 G33--0-X2 G X2 G X2 GA X2 GA33--0-X2 GA X2 GA X2 G X 0 to to to.0 0 to.0 0 to.0 G33 GA33 Vertical side ±3% F.S. (Full span) Stainless steel Glass IP5000, IP6000, I000, IT000, AM2500/3000 ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged. Use a pipe tape for sealing. ecommended tightening torque: /: Set between 7 and 9 N m. 2) When using other fluids, please consult with SM for fluid compatibility information concerning corrosive potential. X2: Stud parts electroless nickel plated X2: Stud parts nickel plated ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G 33 0 gauge Frame type A Vertical side ø30 0 Max. display pressure Unit: X2 X Oil-free X: Oil-free (Wetted parts degreasing) Stud parts electroless nickel plated Wetted parts degrease washing ) X3 (Wetted parts stainless steel) specifications is not available. 2) Please contact SM separately for pressure range of GA33 between 0 and

8 Gauge for General Purpose G3 O.D.: ø3 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G3-0-0 External (Except made-to-order products) ø3 Bleed port The dimensions in ( ): onnecting G3 Port size (), precision ±3% F.S. (Full span) ase Stainless steel lear cover Glass Stud Bourdon tube Applicable model IP200/600, IT600, I2000/3000, IT2000/000 ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product to be damaged.use a pipe tape for sealing. ecommended tightening torque: /: Set between 7 and 9 N m, /: 2 and N m respectively. 2) When using with water, use G3- -X3 (wetted parts stainless steel) and use caution not to apply water hammer. When using the other fluids, please consult with SM for fluid compatibility information concerning corrosive potential. (Standard) G3-2-0 to 02 G3--0 to 02 G3-6-0 G3-7-0 to 02 G3-0-0 to 02 (Made to Order) 0 to to.0 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G3-2-0 to 02-X2, G3--0 to 02-X2 X2: Stud parts G3-6-0-X2 0 to 0.6 nickle plated G3-7-0 to 02-X2, G3-0-0 to 02-X2 0 to.0 G3-2-0 to 02-X3, G3--0 to 02-X3 X3: Wetted parts G3-6-0-X3 0 to 0.6 stainless steel G3-7-0 to 02-X3 G3-0-0 to 02-X3, 0 to.0 G3-2-0 to 02-X, G3--0 to 02-X X: Oil-free G3-6-0-X 0 to 0.6 (Wetted parts G3-7-0 to 02-X degreasing), G3-0-0 to 02-X 0 to.0 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G3 0 size gauge 0 Max. display 02 pressure 3 ø3 2 Unit: ,, X2 Stud parts nickel plated X3 Wetted parts stainless steel Oil-free X (Wetted parts degrease washing) F..L. AV AU AF A I VEX AM ITV I VBA VE VY G PPA AL --9

9 9 Oil-free/External Parts opper-free Gauge/ With Limit Indicator G6E O.D.: ø2 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G6E-0-02M G6E-0-02M- Be sure to read the precautions on page --5 for selection and installation. in: connecting G6E G6E ( DT): With cover ring assembly (For panel mounting) Panel cut dimensions Plate thickness Max. 3.5t (lear cover is not removable.) M x 2 M5 x 0. x 5 (lear cover is removable.) M x 2 M5 x 0. x 5 For mounting method, refer to page --5. Port size () precision Fluid contact part cleaning ase lear cover Stud Attachment: Part no.: 3050-A With cover ring assembly Part no.: A ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product failure. Use a pipe tape for sealing. ecommended tightening torque: : Set between 7 and 9 N m, : 2 and N m respectively. 2) When fluid is water, use G6- -X3. Wetted parts are made of stainless steel construction. (Some corrosion may be caused by water because this product's wetted parts are made of brass.) Design system to not be affected by water hammer when using water as fluid. Similarly, when using other fluids, please consult with SM for fluid compatibility information concerning corrosive potential. 3) Bourdon tube and internal movable parts (gear, etc.) are made of brass and are not electrolessly nickel plated. This is not an internally copper-free product. (Standard) G6E-2-0 to 02M G6E--0 to 02M G6E-7-0 to 02M G6E-0-0 to 02M (Made to Order) G6E-2-0 to 02M-/ G6E--0 to 02M-/ G6E-7-0 to 02M-/ G6E-0-0 to 02M-/ 0 to.0 0 to.0 G6E, ( M: with M5 female ) ±3% F.S. (Full span) Wetted parts degrease washing olled steel (Black melamine painted) Polycarbonate (Hard ) Part no.: G (Electroless nickel plated) Bourdon tube (3) Weight (kg) 0.0 M5 (Female ) ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. M5 (Female ) ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G 6 E 0 0 M gauge 6 ø2.5 Oil-free, E external parts copper-free 0 02 Max. display pressure Unit: M Other versions of this can be made on a made-to-order basis. Please consult SM for details, as delivery times may be extended. With cover ring assembly Attachment (over ring assembly) Without cover ring assembly lear cover has no protrusion. (lear cover is irremovable.) lear cover has protrusion. (lear cover is removable.) With M5 (Female ) ) Use M5 female when piping onto a panel.

10 0 Gauge for lean Series (0-series) G9 O.D: ø ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) Be sure to read the precautions on page --5 for selection and installation. ø / G9 Port size () precision ±3% F.S. (Full span) ase Zinc die-casted (hromate plated) lear cover Stud Glass (Nickle plated for external parts only) Bourdon tube (3) Weight (kg) ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product failure. Use a pipe tape for sealing. ecommended tightening torque: Set between 2 and N m. 2) When fluid is water, use G6- -X3. Wetted parts of G6- -X3 are made of Stainless steel. Use caution as some corrosion may be caused by water. Standard G9 pressure gauge conact area is made of brass. When using water, use caution not to apply water hammer. Similarly, when using other fluids, consult SM for fluid compatibility information concerning corrosive potential. 3) Bourdon tube and internal movable parts (gear, etc.) are made of brass, and are not nickel plated. (Standard) G9--02 G G to.0 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G gauge 9 ø 02 Max. display pressure 7 0 Installation of a filter on the breathing hole (filtration 3 µm) enables an to curb particle generation from the pressure gauge inside. X3 Unit: X3 Wetted parts stainless steel (2) ) over ring assembly is not available. 2) Movable parts (gear, etc) inside pressure gauge are made of brass. 3) Part number for pressure gauge with psi s is G9-P - -X30. This will no longer be sold for use in Japan after the new Weight and Measure Act has been implemented (October, 999). F..L. AV AU AF A I VEX AM ITV I VBA VE VY G PPA AL --

11 Gauge for lean egulator/with Limit Indicator G6 SA, B O.D.: ø2 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) G SA, B (lear cover is not removable.) G S A, B Be sure to read the precautions on page --5 for selection and installation. G SB: With cover ring assembly (For panel mount) M x 2.5(6.5) in ( ): / connecting Panel cut dimensions Plate thickness Max. 3.5t (lear cover is removable.).5(6.5) 5 M5 x 0. x 5 M5 x 0. x 5 M x 2 Port size () precision Fluid contact part cleaning (Wetted part) Assembly/environment () Attachment: cover ring assembly Packaging ase lear cover Stud G6-2-0 to 02-SA G6-2-0 to 02-SB G6--0 to 02-SA G6--0 to 02-SB G SA G SB G SA G SB 0 to.0 G6- -SA G6- -SB, Precision cleaning lean room M5.5 (lass 0000) ±3% F.S. (Full span) Oil/Water free Oil/Water-free (3) Part no.: A Part no.: A General degreasing General production line Stainless steel 30 (Black melamine painted) Polycarbonate (Hard ) Part no.: G Stainless steel 36 Bourdon tube Stainless steel 36 Polyethylene cap for stud parts. Polyethylene cap for stud parts. tight polyethylene bag Polyethylene bag Weight (kg) 0.05 ) When mounting a pressure gauge, use caution not to tighten excessively. Excessive tightening will cause product failure. Use a pipe tape for sealing. ecommended tightening torque: : Set between 7 and 9 N m, : 2 and N m respectively. 2) When using water, use caution not to apply water hammer. When using other fluids, please consult with SM for compatibility information concerning corrosion potential. 3) When manufacturing pressure gauge, SM uses caution not to allow water to remain in the wetted parts. ) Movable parts (gear, etc) inside pressure gauge are made of brass. Made-to-order products, (not including models above) may take longer leadtime. Please consult with SM beforehand. (Standard) ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. G6 0 0 gauge 6 ø2.5 Part number for pressure gauge with psi s is G6-P - -X30. This will no longer be sold for use in Japan after the new Weight and Measure Act has been implemented 999) (October, M Max. display pressure Unit: SA 0 02 M With M5 (Female ) ) Use M5 female when panel-mounting for piping. Attachment (over ring assembly) Without cover ring assembly lear cover has no protrusion. (lear cover is irremovable.) lear cover has protrusion. (lear cover is removable.) Grade omponent parts polishing, Assembly environment omponent parts: Precision cleaning SA Assembly: lean room M5.5 (lass 0000) omponent parts: General degreasing SB Assembly: General production line --2

12 2 Gauge with Switch GP6 O.D.: ø2 ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) A pressure switch function has been added to the gauge. The pressure switch is equipped with a light for verifying operation. The pressure gauge is equipped with a limit indicator. To be used for verifying the supply pressure. ircuit Example Be sure to read the precautions in page --5 for selection and installation. gauge with switch 6 ø2.5 Max. display pressure Unit: 0.0 Gauge switch GP6 Ambient and fluid temperature 5 to 60 (No freezing) Indicated pressure range 0 to.0 Port size () /, / ( M: with M5 female ) precision ±0.03 Setting range (3)() to 0. Hysteresis 0.07 Pointer error (5) ±0.05 (5 to 0 ) ±0.0 ( 5 to 60 ) No freezing ontact With light: a (Normally open) Without light: ab (Normally open/ Normally closed) Wiring Lead wire (Length: 300 mm) Indicator light A Neon light D Light emitting diode (LED) Attachment: With cover ring assembly Part no.: 3050-A Weight (kg) 0.2 ) Indicates the condition at the lower pressure limit. Use a pipe tape for sealing. ecommended tightening torque: /: Set between 7 and 9 N m, /: 2 and N m respectively. 2) Water is not an acceptable fluid. When using the other fluids, please consult with SM for compatibility information concerning corrosion. 3) Set value of pressure switch is indicated by pointer (green). It is the point where the circuit between N.O. (white) and OM (black) is turned off during pressure decrease. To set the value, turn needle in clockwise position to the correct value. When setting; if desired set position has been passed, turn needle in a counterclockwise direction back again beyond the desired value and then once again return needle in a clockwise direction stopping at the desired value. Value must be set while needle is traveling in a clockwise direction. ) Make sure to provide a minimum difference of 0. between the set pressure and the operating pressure (including the pressure drop). If the difference is smaller, it could lead to improper operation. efer to page --5 for details on how to set the setting needle. Use caution: Operating pressure should be the sum of the pressure of the setting needle error (±0.05 ), the hysteresis (0.07 ), and the display accuracy (±0.05 ) on the set pressure value, or the circuit between N.O. (white) and OM (black) may not turn ON while pressure is increasing. 5) Maximum error value: Add the pressure gauge indicator error of 0.03 to the setting needle error. Other versions of this can be made on a made-to-order basis. Please consult with SM for details, as delivery times may be extended. (Standard) Micro-switch ated Voltage Load ated voltage Operating current range GP6 0 0 M M With M5 (Female ) L2 L range () Load resistant 30 VD 25 VA 250 VA 0.0 to 0.5 A 0.0 to 0.3 A 0. A Indicator light Without indicator light Neon light (00 VA/220 VA) LED/2 VD GP6-0-0 to 02 GP6-0-0 to 02L2 0 to.0 GP6-0-0 to 02L5 ) Do not apply pressure more than the maximum display pressure. This will cause a malfunction. L2 X20 X20 Lead wire length 3 m ) X3 (Wetted parts stainless steel) specification is not available. 2) Part number for pressure gauge with psi s is G6-P - -X30. This will no longer be sold for use in Japan after the new Weight and Measure Act has been implemented (October, 999). Attachment (over ring assembly) Without cover ring assembly lear cover has no protrusion. (lear cover is irremovable.) ) (lear cover has protrusion. / lear cover is removable.) is not compliant. --3 F..L. AV AU AF A I VEX AM ITV I VBA VE VY G PPA AL

13 3 ircuit Diagram Without indicator light N. (ed) NO. (White) OM. (Black) GP6 Pointer (Green) Setting screw ( ): / Limit indicator Indicator light ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) With indicator light 0, 220 VA 2 VD N. (ed) NO. (White) Load OM. (Black) N. (ed) NO. (White) Load OM. (Black) The arrow in the diagram indicates the direction of the pressure increase. The light turns OFF when the pressure becomes higher than the set pressure and turns ON when the pressure becomes lower than the set pressure. GP6: With cover ring assembly (For panel mounting) lear cover is not removable. M x 2 M5 x 0. x 5 efer to page --5 for mounting method. Panel cut dimensions Plate thickness Max. 3.5t --

14 Procedure for Setting the Limit Gauge Indicator Procedure for Setting the Limit Gauge Indicator and the Setting Needle () Before setting the (green) limit indicator, turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then, remove by pulling it towards you. over () Before setting the limit indicator and the (green) setting needle, turn the cover counterclockwise (approximately 6 to 7 mm) until it stops. Then, remove by pulling it towards you. over Turn counterclockwise Turn counterclockwise Pull (2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate. Limit indicator Pull (2) Use a flat head screwdriver (with a 2.9 mm blade width) to set the (green) limit indicator. Be careful not to bend the other needle or damage the dial plate. Limit indicator F..L. AV AU AF ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A Main Office: (650) Local Area: (00) (3) After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case. aution aution Mark Flat head screwdriver Top hollow Slit Precautions Be sure to read before handling. efer to pages -2-3 to -2- for Safety Instructions and ommon Precautions. Selection. Do not apply high load voltage (current) or surge current as this can cause the switch to malfunction. 2. Make sure that no direct impact or vibrations are applied to the body. 3. If operating under pressure pulsations or in high frequency operations, please contact SM. Mounting. During transport and installation, do not apply shock to the product, such as by dropping doing so will affect its precision. 2. egarding the installation posture, place it perpendicular to the ground, with the zero point on the reading of a pressure gauge facing down. 3. Do not install it in an area that is exposed to high temperature or humidity, because doing so will lead to improper operation.. To screw in the pressure gauge, make sure to turn the gauge by placing a wrench over the square wrench flats.if the pressure gauge is screwed in by holding it on some other area, air leakage or damage may result. (3) Before setting the setting needle, use a flat head screwdriver (with a 2.9 mm blade width) to turn the setting screw and set the setting needle to the set pressure. In the case of turning the set screw lockwise Increase of setting press. ounterclockwise Decrease of setting press. () After completing the setting, replace the cover. Fit the cover by aligning the cutout in the cover to the groove on the top of the black case. Turn the cover clockwise (approximately 6 to 7 mm) until it stops. Make sure that the matching mark on the cover is aligned with the groove on the top of the case. Mark Flat head screwdriver Flat head screwdriver Top hollow Slit Procedure for Assembling the over ing Assembly gauge for general purpose switch emove screw gauge with switch emove screw over ring Attach small screw. emove the small screw ( position) from the pressure gauge. 2. Place the cover ring on the pressure gauge. 3. Using the small screw that is provided with the cover ring, install the cover ring. The installation torque is 0.3 to 0.5 N m. A I VEX AM ITV I VBA VE VY G PPA AL --5

Standard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1

Standard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1 Pressure Gauge for General Purpose Series G5/G27 G5 G27 G5-0-0 G27-0- Be sure to read the precautions on page 663 for selection and mounting. Dimensions Port size () precision ±5% F.S. (Full span) Case

More information

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ

Clean Regulator. SRH Series. Contamination controlled stainless steel regulator ARJ Clean Regulator Series IR IRV VEX SRP ITV IC T AP1 Contamination controlled stainless steel regulator 855 Clean Regulator Series Contamination controlled stainless steel regulator Oil free Outstanding

More information

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure

Standard Specifications. Model IN side OUT side Fluid Proof pressure Maximum operating pressure Miniature Regulator Series ARJ1020F 2 Construction/Dimensions Lock nut M8 X 0.75 Panel screw Panel mounting hole Precautions Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety

More information

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121 Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 6-580 www.cmafh.com VEF Port Port Applicable power Body size Body size Electro-pneumatic Proportional

More information

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Specifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette Finger Valve Series VHK ohs Large effective area:.0 to 7.5 mm Small knob operating force: 0.04 to 0.4 N m Poppet valve construction seldom suffers seal defection. The series begins with the min. tubing

More information

Note) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2

Note) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2 Mist Separator Series ohs Can remove oil mist in compressed air and separate and remove particles such as rust or carbon of more than 0.3 µm. Modular connection is possible with 150C to 550C. (For details,

More information

Miniature Regulator Series ARJ310

Miniature Regulator Series ARJ310 Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42) Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable

More information

Tube Applicable for nylon, soft nylon and polyurethane tubing.

Tube Applicable for nylon, soft nylon and polyurethane tubing. Miniature Fittings Series M pplicable Tubing: ø3.2, ø4, ø6 onnection Thread:, M, arb onfiguration for easy insertion into the tube Holds the tube tightly ody With electroless nickel plated Low tightening

More information

Air Filter. Best Pneumatics 4. Equipment. Air Line

Air Filter. Best Pneumatics 4. Equipment. Air Line est Pneumatics Air Filter Air Filter: AF000 to 6000 P..- Mist Separator: AFM000/000/00 P..-6 Micro Mist Separator: AF000/000/00 P..-9 Large Flow Air Filter: AF00/0 P..- Air Line Equipment.-0 Modular Style

More information

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures us enclosures G. us enclosures Enclosure:.38 Door:.5 IP 65 to EN 60 59/09.00, complies with NEMA. Door with l/h hinge, cam lock with double-bit insert, () support rail(s) S 35/7.5 (for G 586.). Drilled

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

SECTION METERS AND GAUGES FOR HVAC PIPING

SECTION METERS AND GAUGES FOR HVAC PIPING SECTION 23 05 19 METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Work included: Provision of materials, installation and testing of: 1. Thermometers 2. Thermometer Wells 3. Differential

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

ARM1000/2000. Standard Specifications

ARM1000/2000. Standard Specifications .5- Regulator Manifold ARM000/000 4 connection methods Standard Specifications Fluid Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Cracking pressure (Valve) Construction

More information

LW Series offer flexibility in space-saving package

LW Series offer flexibility in space-saving package ourtesy of Steven Engineering, Inc. 230 yan Way, South San Francisco,, 94080-6370 Main Office: (650) 588-9200 Outside Local rea: (800) 258-9200 www.steveneng.com LW Series offer flexibility in space-saving

More information

4 Port Solenoid Valve

4 Port Solenoid Valve Port Solenoid Valve Rubber Seal Direct Operated Poppet Type Unprecedented high speed, with stable response times ON: ms, OFF: ms, Dispersion accuracy ±1 ms ( at a supply pressure of 0. MPa) (Use clean

More information

Mechanical Style Pressure Switch. Specifications

Mechanical Style Pressure Switch. Specifications or details about certified products conforming to international standards, visit us at www.smcworld.com. Mechanical Style Pressure Switch Series IS1000 Long service life: 5 million cycles IS1000-01 IS1000-01-X202

More information

Standard Specifications

Standard Specifications Miniature Regulator ARJ020F Compact and lightweight (6g) Low cracking pressure 0.02MPa Standard model equipped with backflow function Standard Specifications Port size IN side OUT side (Applicable tube

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

Plug: KBP Elbow module: KBV Female connector union: KBH. Tubing. Guide. Chuck Collet. O-ring Lock ring. Spring Spring guide. Specifications.

Plug: KBP Elbow module: KBV Female connector union: KBH. Tubing. Guide. Chuck Collet. O-ring Lock ring. Spring Spring guide. Specifications. Piping Module Series KB RoHS Plug: KBP Elbow module: KBV Female connector union: KBH Lock ring Plug body hread Spring Spring guide Release button (blue) Seal Stud Universal elbow body ubing Guide Chuck

More information

Example. U side. Stations SY5000

Example. U side. Stations SY5000 45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

3 Port Solenoid Valve Direct Operated Poppet Type

3 Port Solenoid Valve Direct Operated Poppet Type 3 Port Solenoid Valve Direct Operated Poppet Type VK300 Series Rubber Seal [Option] Universal porting Available for N.C. valve, N.O. valve, divider valve, selector valve, etc. C: 0.80 dm 3 /(s bar) (Passage

More information

Vacuum Ejector with Solid State Timer

Vacuum Ejector with Solid State Timer Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting Series Elbow Type Reduces labor time! Elbow Brass Stainless steel Electroless nickel plated Stainless steel 33 RoHS TMH y Easo t e us Push-lock type Larger handle

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Vacuum System Peripherals

Vacuum System Peripherals Vacuum System Peripherals Vacuum Regulator/Electronic Vacuum Regulator Vacuum regulator: IRV0/0 Electronic vacuum regulator: ITV009/ITV09 Directional Control Valve Selection guide of directional control

More information

Hydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4

Hydraulic Filters. Element (µm) nominal filtration. Port size. Micromesh 74, 105, 149 1/2, 3/4, 1, 1 1/4, 1 1/2, 2, 2 1/2, 3, 3 1/2, 4 Hydraulic Filters Series Series Operating pressure Port size (µm) nominal filtration Accessory (Option) Page Vertical Suction Filter Series FHIA Suction Filter with ase Series FH Suction Guard Series FHG

More information

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example E-P HYREG VY Series This hybrid regulator combines a regulator and a solenoid valve. Stepless control through electric signals Port sizes M5 to inches can be covered by combining an ultra-compact electro-pneumatic

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR ITV2 Electro-pneumatic Regulator Electronic Vacuum Regulator Series ITV Series ITV Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an

More information

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type Series 000 Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications Port Solenoid Valve Direct Operated Poppet Type 000 Series Rubber Seal [Option] C: 0. dm /(s bar) (Passage {/ / (A/B R/R)}) Compact: Width 8 x Length 8 (mm) Low power consumption W DC (Standard type) W

More information

Series IW. Filter Regulator

Series IW. Filter Regulator Standard Specifications Model IW212 IW213 IW215 IW222 Adjustable type (Basic) Fixed type Maximum supply pressure Max. 1. MPa.3 to 1. MPa Set pressure.2 to.2 MPa.2 to.3 MPa.2 to.5 MPa.14 MPa Air consumption

More information

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal Port Direct Operated Poppet Solenoid Valve, Rubber Seal Series 3000 or details about certified products conforming to international standards, visit us at www.smcworld.com. C: 0.4 dm 3 /(s bar) (Passage

More information

Non-Contact Sensor for Workpiece Placement Verification

Non-Contact Sensor for Workpiece Placement Verification ir Catch Sensor Series 2 Non-Contact Sensor for Workpiece Placement Verification Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact

More information

Series AV2000/3000/4000/5000

Series AV2000/3000/4000/5000 Soft Start-up Valve Series AV/3/4/5 Series introduced! A start-up valve that gradually increases supply pressure during start up and rapidly exhausts system air when the supply air is shut off AC AV AU

More information

WINTERS ( )

WINTERS ( ) Economy Economy Test Panel Mounted Economy Spiral Tube Series New Sizes! Economy CRN Description The Winters Economy Gauge is designed for applications where cost savings are paramount. Many configurations

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

Wedge Cam Operation Slide Guide. Air Gripper/2-Finger Type ø12, ø16, ø20, ø25. Option: Stainless steel

Wedge Cam Operation Slide Guide. Air Gripper/2-Finger Type ø12, ø16, ø20, ø25. Option: Stainless steel Wedge Cam Operation Slide Guide Air Gripper/2-inger Type ø2, ø, ø, ø2 MH MH oad Resistant, Dust Cover for Adverse Environments 2 types of finger materials types of dust cover materials Standard: Carbon

More information

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type.

How to Order Valve. Body type. Symbol Body type B Base mounted with screws 10 S070 B 5 B G 10 S070 C 5 B G 32. Body type. Series -S00 ompact Direct Operated Port Solenoid Valve ontrol Valves ase mounted ody ported lean Series lean Series V S R oil voltage 24 VD VD VD VD VD Power consumption Pressure specification Flow rate

More information

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard

How to Order 02 1/4. Thread type Nil Rc N NPT * * Semi-standard Filter Regulator IW Series Two types are available: adjustable set pressure type and fixed set pressure type. Low/High temperature and external parts copper-free types can be selected. Pressure gauge connecting

More information

Transmitters: Relay Valve VR4151/4152

Transmitters: Relay Valve VR4151/4152 Relay Valve VR4151/4152 Appropriate output sequences are affected according to the signal received from the mechanical valve. VR4151 VR4152 Precautions Be sure to read before handling. Refer to pages 5-11-2

More information

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves MicroCoat System Operating Manual MC Series MC785M, MC785M-WF Spray Valves A NORDSON COMPANY Introduction The MicroCoat System provides precise lubrication control for metal stamping operations. The MC

More information

Free Mount Cylinder for Vacuum

Free Mount Cylinder for Vacuum Free Mount Cylinder for Vacuum Series A free mount cylinder with a vacuum passage in the rod to meet the requirements for Air cylinder + Vacuum pad. A vacuum passage has been provided in the rod of the

More information

Precision Clean Regulator

Precision Clean Regulator Precision Clean Regulator Series AR45 AMR ARM -A VY AP00 High precision, low flow consumption stainless steel regulator 869 Precision Clean Regulator Series High precision, low flow consumption stainless

More information

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type 230.15 Mechanical Pressure Measurement WIKA Datasheet 230.15 Applications Semiconductor and electronic industry, medical industry, gene

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-pneumatic proportional valve: Flow type (VEF) Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical throttle valve function.) A model that is suitable

More information

Power Valve Precision Regulator

Power Valve Precision Regulator Power Valve Precision Regulator VEX Series High precision, large capacity relief regulator port large exhaust capacity pressure reducing valve which utilizes a nozzle flapper mechanism available as air

More information

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model.

Speed Controller with Uni One-touch Fitting Push-lock type. New-stand male threads for piping that reduces the screw-in time by 1/3. Model. Speed Controller with Uni One-touch Fitting Push-lock type Series Elbow Universal Brass New-stand male threads for piping that reduces the screw-in time by 1/3. Gasket Female thread Rc, G NP, NPF Shape

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Rubber Seal Port Solenoid Valve Series Manifold Single Unit ase Mounted Manifold VV01 V100 ar base P.18 ody Ported P.10 ase Mounted P.10 VQD VKF VK VT VS Separable base ody Ported Manifold P.1 Stacking

More information

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4

ASP330F-01 ASP430F-02 ASP530F-03 ASP630F-04 ASP430F-F02 ASP530F-F03 ASP630F-F04 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/8 NPT 1/4 Pilot check valve and speed controller are combined. Realizes momentary intermediate stoppage of a cylinder and able to adjust speed control of it. Work piece Example of drop prevention circuit Tubing

More information

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range

Electro-Pneumatic Regulator. Standard Specifications. Minimum supply pressure Maximum supply pressure Regulating pressure range 000 Electro-Pneumatic Regulator Series 000/000 Standard Specifications Symbol Straight type Right angle type Model Minimum supply pressure Maximum supply pressure Regulating pressure range Voltage Power

More information

Series SV1000/2000/3000/4000

Series SV1000/2000/3000/4000 Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option. 3 Port Solenoid Valve Direct Operated Poppet Type Series VT325 Rubber Seal [Option] Note) Applicable only for DIN terminal type. Compact yet provides a large flow capacity Dimensions (W x H x D) 55 x 118

More information

Approvals, see page 41. Detailed drawing, see page 1226/1227.

Approvals, see page 41. Detailed drawing, see page 1226/1227. Ex enclosures Stainless steel F G B.7 With screw-fastened lid Material: Stainless steel.40 (AISI 04) Surface finish: Brushed, grain 40 Protection category: IP 66 to EN 60 9/09.00 Supply includes: Enclosure,

More information

Compact Slide. Series MXH ø6, ø10, ø16, ø20

Compact Slide. Series MXH ø6, ø10, ø16, ø20 Compact Slide Series ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Endless track linear guide Series Variations

More information

B21 Series BASOTROL Gas Valve

B21 Series BASOTROL Gas Valve Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully

More information

Related Products VR4151/4152 Relay Valve

Related Products VR4151/4152 Relay Valve Related Products VR4151/4152 Relay Valve Appropriate output sequences are affected according to the signal received from the machanical valve. Specifications 1 Fluid Air Operating pressure 0 to 1.0MPa

More information

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)* 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator ITVH Series ARJ RoHS Maximum supply pressure Set pressure range Stability 3.0 MPa 0.2 to 2.0 MPa ARX AMR Stepless control of air

More information

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL SMC REULATOR Electro-pneumatic Regulator Electronic Vacuum Regulator Series Series Series Model Regulating pressure range Port size With a simplified high-density circuit board design, an extremely compact

More information

Information. Model LEYG16 LEYG25 LEYG32

Information. Model LEYG16 LEYG25 LEYG32 Information A rod type with guide newly added! Compatible with slide-bearing and ball-bushing bearing. Compatible with moment load and stopper (slide bearing). Speed control/positioning: ax. points Positioning

More information

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody

MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody MEMORY SEAL BALL VALVES MAINTENANCE MANUAL 2 12, Class 150 & 300, Regular Port, Flanged Unibody I INTRODUCTION These rugged, versatile, high performance, regular port, ball valves meet all requirements

More information

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type

Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type Bourdon Tube Pressure Gauges Ultra High Purity (UHP) Series Type 230.15 Mechanical Pressure Measurement WIKA Datasheet 230.15 Applications Semiconductor and electronic industry, medical industry, gene

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly

More information

Series AN /Series AMC

Series AN /Series AMC s/exhaust Cleaner / Noise reduction Nominal filtration rating (eference values) Oil mist removal ratio Standard type Low back pressure Compact and easy mounting 00 30 db (A) 00 µm 50 µm 5-0-2 Compact type

More information

Transmitters: Relay Valve

Transmitters: Relay Valve Relay Valve VR5/5 Series Appropriate output sequences are affected according to the signal received from the mechanical valve. It is equivalent to the auxiliary relay of an electrical system. Specifications

More information

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation Air Catch Sensor Non-Contact Sensor for Workpiece Placement Confirmation Stable detection of. to. mm clearance Due to the pneumatic bridge circuit and semiconductor pressure sensor, the non-contact type

More information

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines Applications The V46 pressure-actuated and V47 temperatureactuated water-regulating valves are used for water-cooled condensers, bypass service on refrigeration systems, engine cooling, and various industrial

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42) Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of

More information

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Flow characteristics Max. (1) b Standard Specifications. P Manual override. Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-

More information

5. SEPARATE STEERING INTERMEDIATE SHAFT ASSY (a) Fix the steering wheel with the seat belt. Release the 3 springs and separate the dust cover.

5. SEPARATE STEERING INTERMEDIATE SHAFT ASSY (a) Fix the steering wheel with the seat belt. Release the 3 springs and separate the dust cover. 5119 OVERHAUL When installing, coat the parts indicated by the arrows with power steering fluid or molybdenum disulfide lithium base grease (See page 5116). 1. INSPECT CENTER FRONT WHEEL 510DA02 2. REMOVE

More information

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE 6 FL7M-A Series FEATURES Workpieces Reliably Sensed Even if Aluminum or Cast Iron Chips Accumulate on the Sensing Head. This DC 2-wire type proximity sensor can be directly connected to programmable controllers

More information

SA1W: Water Detection Sensors

SA1W: Water Detection Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com The SA1W is the fastest, most reliable

More information

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY

NEECO INDUSTRIES INC. INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY INSTRUCTION MANUAL 7 1/16 10K SLAB GATE BODY INTRODUCTION The NF-700 type gate valves provided by Neeco Industries are full-bore through conduit non-rising stem manually (w/ball screw) operated valves.

More information

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0. 000 Electro-Pneumatic Regulator Electronic Vacuum Regulator Series Series Model Set pressure range Port size Page Series 000 Controls air pressure steplessly in proportion to an electric signal. 0 05 to

More information

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa

How to Order 1 T Z A. r Pressure range. 05 Pressure range 0 to 0.5 MPa 10 Pressure range 0 to 1 MPa 16 Pressure range 0 to 1.6 MPa oolant Valve Series S External pilot solenoid S ir operated S How to Order 0 0 Y 0 0 T Z q w e r t y u i o!0!!!!! q Series S00 S00 S00 w Valve type ormally closed ormally open e Seal material R FKM r Pressure

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level. SERIES LED Bar Display Mechanical Switch is Out of Date Choose the Contemporary Pressure Sensor with LED Bar Display Marked Conforming to EMC directive Bright LED Bar Display Easy to read the pressure

More information

Series PW

Series PW Series 2000300040005000 Filter Regulator Specifications H U 2000 3000 Model 2000 3000 5000 Port size Rc(PT)/NPT 1/8", 1/4" 1/4", 3/8" 3/8", 1/2" 3/4", 1" Max. Supply Pressure 1.5MPa(213 PSI) Max. Operating

More information

BALL VALVES FILTERS TEST POINTS 8

BALL VALVES FILTERS TEST POINTS 8 BALL VALVES FILTERS TEST POINTS 8 8 PRODUCT CATALOGUE 357 HYDROSCAND BALL VALVES, FILTERS TEST POINTS TABLE OF CONTENTS BALL VALVES PAGE BALL VALVES The ball valves are mainly used as shut-down valves

More information

Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily.

Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily. P099-P0998-E.qxd 0..5 :5 AM Page 99 Directional Control Driver for Electric Cylinder Series LCF LJ LG LCF-5A 첸 LCF-5A5 첸 LTF Able to control the stroke with only / signals. LC Directional control driver

More information

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP Micro Ejector Order Codes Manifold Order Codes Micro ejector single unit (without solenoid valve) ME Body model nozzle diameter : Maximum flow rate on vacuum side 03 0.3 : 3.0R/min. [0.012in., 0.106ft.

More information

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette

Specifications. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette Finger Valve Series RoHS Large effective area:.0 to 7.5 mm Small knob operating force: 0.04 to 0.4 N m Poppet valve construction seldom suffers seal defection. The series begins with the min. tubing O.D.

More information

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump

VNA Application example. 3-port dual pressure, N.C. type SGH. Nozzle SGH. Coolant pump igh Pressure oolant Valve eries Pa/ orresponding to high speed grinding and long drilling processes oolant valve for high pressure coolant liquid (up to Pa/) that is ideal for lubrication, dust blowing

More information

Installation. Installation. 12. System Diagram... 10

Installation. Installation. 12. System Diagram... 10 Pressure Control Systems Installation Instructions Form No. F-1031 Section 3010 Issue Date 08/20/96 Rev. Date 9/11/17 Table of Contents Discharge Relief Valve System System Description....................................

More information

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body

More information

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110 Best 1 Pneumatics Transmitters Relay valve P. 1900 Side piping: 30 x 53 x 91 Bottom piping: 30 x 8 x 91 VR151 VR152 Effective area (mm 2 ) Number of ports Function 7 5 Metal Spool Shuttle valve P. 1902

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x x 46 mm) Four contacts Gold-plated contacts

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such

More information

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure

Miniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing

More information

SPEED CONTROLLERS WITH QUICK FITTINGS

SPEED CONTROLLERS WITH QUICK FITTINGS SPEED CONTROLLERS WITH QUICK FITTINGS Union Straight Type Fittings for controlling the speed of actuators, such as cylinders. Superior flow rate characteristics and fine tuning adjustments in the low flow

More information

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option

3 Port Solenoid Valve Direct Operated Poppet Type. Body type. Body ported. Manifold. Valve option Port Solenoid Valve Direct Operated Poppet ype Series V17 Rubber Seal [Option] Compact yet provides a large flow capacity Dimensions (W x H x D) 45 x 89.5 x 45 (Grommet) C:.6 dm /(s bar) (Passage ) Suitable

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

Electric Actuator/ Guide Rod Type

Electric Actuator/ Guide Rod Type ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Size How to Order LEYG M B 50 S N1 Bearing type M Sliding bearing L Ball bushing bearing

More information

Speed Controller with One-touch Fitting

Speed Controller with One-touch Fitting Speed Controller with One-touch Fitting S Series Push-lock Type Reduces labor time! Easy to use Easy to lock Unlock Push-lock type Lock Improved tube insertion/removal Max. Insertion force: 30% (8 N) reduction

More information