Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily.
|
|
- Arthur Walter Mosley
- 6 years ago
- Views:
Transcription
1 P099-P0998-E.qxd 0..5 :5 AM Page 99 Directional Control Driver for Electric Cylinder Series LCF LJ LG LCF-5A 첸 LCF-5A5 첸 LTF Able to control the stroke with only / signals. LC Directional control driver like a solenoid valve LC8 LC7 LXF Able to set thrust arbitrarily. LXP LXS Thrust can be adjusted by adjustment trimmer. LC6첸 Able to control with only different types of input signals. LZ첸 LCF q Directional instruction w Thrust selection e Output / X첸 D-첸 Can be operated manually. E-MY Maintenance performance for wiring check has been improved. Product Specifications Model LCF-5A첸 VDC ± 0% Power supply Front side label color Input signal Selction of thrust Ambient temperature Ambient humidity Environment LCF-5A5첸 Max.. A Max.. A Gray Blue Photocoupler input VDC ±0% Max. 8 ma/point 00% or set value (Setting range 0 to 70% F.S.) +5 to 0 C 5 to 85% Rh (No condensation) Indoor (Direct sunlight should be avoided.) No corrosive gas, inflammable gas, oil mist or dust particle Display LED Mass POWER,,, 5 g 99 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800)
2 Directional Control Driver for Electric Cylinder Series LCF RoHS How to Order Option LCF A A5 Power supply 5 VDC Applicable motor DC motor (Cylinder size ) DC motor (Cylinder size 5) 5AB Housing set (Connector set) Housing for CN,, (connector) & contact A (connector pin) are included as an accessory. B Nothing included. Cable for power supply terminal LCF C 0 Cable type Cable for CN power C supply terminal Cable length 0 0 m m Cable for control terminal LCF C 0 Cable type Cable for CN C control terminal Cable length 0 0 m m Cable for motor output terminal LCF C 0 Cable type Cable length Cable for CN motor C output terminal 0 05 m 5 m Housing set (Connector set) LCF C0 Housing for power supply terminal (Connector) Housing for control terminal (Connector) Housing for motor output terminal (Connector) Contact (Connector pin) 60 ± 5 Cable length 60 ± 5 60 ± 5 Cable length 60 ± 5 CN Control Table COM Common terminal Output Adjusted thrust Traveling direction 60 ± 5 Cable length 60 ± 5 pc. pc. pc. pcs. VHR-N: J.S.T. Mfg Co., Ltd. VHR-N: J.S.T. Mfg Co., Ltd. VHR-N: J.S.T. Mfg Co., Ltd. BVH-T-P.: J.S.T. Mfg Co., Ltd. CN Power Supply Table Do not apply repetitive bending or pulling stress to the cable. Wiring with repetitive bending or pullling stress to the cable will likely cause the cable to break. In the event of crimping the contact (connector pin) and wire, use the specified tools as well as the recommended cable. Crimping tool: YC-60R (J.S.T. Mfg Co., Ltd.) Pulling tool: EJ-NV (J.S.T. Mfg Co., Ltd.) Recommended cable connection (common for individual cable) AWG (0.5 mm ), Insulated wire O.D..7 to.0 mm with shield, Heat resistance is more than 80 C. Maximum cable length CN cable for power supply terminal m CN cable for control terminal m CN cable for motor output terminal 5 m Shield is attached with an optional cable for the LCF series. When grounding a shield, remove the sheath and use a metal U-crip or P-crip. 99 : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) : B-PHASE (Extended side) FG Frame ground DC (+) Driver power supply (+ V) DC ( ) Driver power supply (0 V) Pin number Pin number Optional cable color Yellow/Green Brown Blue Optional cable color White Red Yellow Orange CN Motor Output Table Pin Optional number cable color OUTA Motor output A (Blue) Blue OUTB Motor output B (Red) Red Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800)
3 Directional Control Driver for Electric Cylinder Series LCF Applicable Cylinder Table Cylinder part no. L Z - A - L Z 5 - A5 - Applicable directional control driver LCF-5A LCF-5A5 Dimensions Mounting 5.5 CN control terminal M x 0.5 For protection grounding terminal mounting x ø.6 For main body mounting Consider the cooling period, so that the operating temperature of main body should be within the range of specifications. Also, allow enough distance from each side of the main body, construction and the parts. Cooling should be considered, so the surface temperature of a heat sink should not be more than 50 C even though the temperature is within the operating range mm (.5) () CN power supply terminal CN motor output terminal Protection grounding terminal Protection grounding Cross recessed bind screw M x pc. terminal Spring washer Nominal pc. related components Tooth lock washer (A) Nominal pc. Related components for mounting the protection grounding terminal are provided together with the product. LJ LG LTF LC LC7 LC8 LXF LXP LXS LC6 LZ LCF X D- E-MY How to Mount Mount the directional control driver vertically against the wall, using two mounting screw holes, so the front side (on which its adjustment trimmer and manual switch are located) is facing to an operator. Applicable mounting screw: M ( pcs.) [to be supplied by customer] How to mount a protection grounding terminal Cross recessed bind screw (Accessory) M x.6 Spring washer Nominal (Accessory) Crimping terminal 78.6 Tooth lock washer (A) (Accessory) Nominal Note) Crimping terminal and grounding cable are supplied by customer. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800) x ø.6 995
4 Series LCF Wiring Example Single phase 00 VAC MCCB Noise filter MC CN power supply terminal Power supply VDC DC (+) DC ( ) Series LCF MC FG MCCB: Circuit breaker MC : Contactor Ry : Relay MC Ry Rated input VDC ±0% Max. 8 ma/point Blue Red Electric cylinder mounted motor Surge suppressor CN motor output terminal OUTA OUTB CN control terminal COM Ry Emergency stop signal For System Chart, refer to page 78. Do not short circuit the motor output terminal (CN). Excessive current will flow, and the directional control driver may become damaged. How to wire CN motor output terminal Warning CN power supply terminal There is no emergency stop function or power supply switch in the directional control driver. Please be sure to provide an emergency stop and power supply insulation (insulator) device as a total machine equipment, referencing the above wiring examples. Also, please be sure to turn off the power supply for the whole equipment prior to wiring the directional control driver. CN control terminal Heat sink side CN Power Supply Pin no. FG DC (+) DC ( ) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Frame ground Driver power supply (+ V) Driver power supply (0 V) CN Motor Output Pin no. OUTA OUTB Motor output A (Blue wire) Motor output B (Red wire) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) 996 Heat sink side CN Control Pin no. COM Output Adjusted thrust Traveling direction Common terminal : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) Note) : B-PHASE (Extended side) Note) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 980, 98, 986 and 987. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800)
5 Directional Control Driver for Electric Cylinder Series LCF Description of Each Part and its Category Description Details Trimmer Thrust adjustment trimmer Thrust changes through adjustment. POWER Light illuminates when power is supplied. Indicator light Light illuminates by command. (Travelling to the retracted side when illuminated) Light illuminates when turning. (No motor output is generated when illuminated.) LJ LG Light illuminates by command. (Thrust set by the thrust adjustment trimmer, when illuminated, will be outputted.) LTF Manual switch command while pressing (Travelling to the retracted side) command while pressing (Motor output will be generated.) command while pressing (Thrust set by the thrust adjustment trimmer will be outputted.) LC LC7 LC8 Timing Chart Warning. Do not operate or adjust settings with wet hands. You may experience an electric shock.. When operating the manual switch, make sure that your hands do not come in contact, or is caught between the workpiece. Otherwise you may become injured.. Do not press the manual switch with sharp objects, as the manual switch may be damaged.. Do not touch the directional control driver's heat sink. It will be very hot while turned on, so operate after you have checked that it has become cold.. Adjust the thrust adjustment trimmer under the conditions below. ) Adjust so that the pressure applied to the thrust adjustment trimmer remain below.9 N. ) The adjustment section of the thrust adjustment trimmer should be below 68.6 mn m. LXF LXP LXS LC6 LZ LCF X D- E-MY (Extended side) Note) 00% CN Control Pin no. COM Output Adjusted thrust Traveling direction Common terminal : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) Note) : B-PHASE (Extended side) Note) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 980, 98, 986 and 987. Thrust 0% (Retracted side) Note) 00% Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 980, 98, 986 and 987. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800)
6 Directional Control Driver Specific Product Precautions Be sure to read before handling. External force (Manual or spring loaded) Thrust on Design and Operation. If an electric cylinder with DC motor should be rotated by the larger external force than the generated thrust, the reverse inrush voltage generated may cause adverse effects on the electric cylinders directional control driver and result in malfunction or damage to the product. Example) Do not push or pull a cylinder rod, applying a larger load or external force than the generated thrust. (Please use caution if the generated thrust should be switched over between a high thrust and a low thrust.) LCF Do not use this product by stopping it with a load or external force. (control operation) LCF Command an operation in the reverse direction only after a cylinder rod stopped completely. LCF Do not operate a cylinder rod with an external force when the electric cylinder directional control driver is turned off or output is in the off state. (If a cylinder rod needs to be moved manually for the purpose of adjustment, etc., be sure to remove the CN motor output terminal beforehand.) LCF LCF 998 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (650) Outside Local Area: (800)
Directional Control Driver for Electric Cylinder
Directional Control Driver for Electric Cylinder LCF Series RoHS LEF LEJ LEL LEM LES Product Specifications LCF-5A LCF-5A5 Able to control the stroke with only / signals. Directional control driver like
More informationElectric Cylinders. It can be operated like an air cylinder. Directional control driver like a solenoid valve
CAT.ES0-58 B Electric Cylinder Electric Cylinders It can be operated like an air cylinder. Series LZB Series LZC Model LZB LZC Max. thrust Max. speed Lead screw Stroke 196 N 00 mm/s Slide screw: ø8, ø1
More informationElectric Cylinders. It can be operated like an air cylinder. Directional control driver works like a solenoid valve
CAT.EUS0-58 B -UK Electric Cylinder Electric Cylinders It can be operated like an air cylinder. Series LZB Series LZC Model LZB LZC Max. thrust Max. speed Lead screw (mm) Stroke (mm) 196 N 00 mm/s Slide
More informationLZB/LZC. Series LZB LZC. Electric Cylinder. Series. Series LJ1 LG1 LTF LC1 LC7 LC8 LXF LXP LXS LC3F2 E-MY LZB LZC
P097-P0992-E.qxd..1 11:3 AM Page 97 Electric Cylinder Series LZB/LZC. r e d n yli e k i l d te It can LJ1 c r i a an LG1 LTF ra e p o be LC1 LC7 LC8 LXF Series LXP LZB LXS LC6첸 LZ첸 LC3F2 X첸 Series D-첸
More informationCircuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control
Port Electro-Pneumatic Proportional Valve Series 000/000 Capable of actuating a cylinder and performing analog control of pressurization alone can be used to switch and actuate a cylinder and to perform
More informationFlow characteristics Max. (1) b Standard Specifications. P Manual override.
Port Direct Operated Solenoid Valve Series 0 Metal Seal Model Number of positions (Single) (Double) ( position) JIS Symbol Model Port size Rc (Nominal size) 0-0 8 ( A) 0- ( 8A) 0-0 8 (0A) 0-0 8 ( A) 0-
More informationCompact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M
Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector
More informationElectric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC
Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,
More information3 Port Solenoid Valve
Port Solenoid Valve Series VQ00 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, C 9080-0-Main Office: (0) 88-900-Outside Local rea: (800) 8-900-www.stevenengineering.com Outstandingly
More informationHow to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"
Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector
More informationHead-separated Digital Pressure Sensor DP5 SERIES DPH SERIES
76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor
More informationMEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information
MEMS Air Velocity Sensor Compact, intelligent sensors featuring MEMS precision technology for repeatable airflow detection. Precision uni-directional air velocity detection. Integral passive Dust Segregation
More information2/3 Port Mechanical Valve. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)
2/3 Port Mechanical Valve Series 00 Large flow capacity. A variety of actuator types. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)
More informationSeries SV1000/2000/3000/4000
Valve/Sub-plate Type IP67 Compliant Series 000/000/000/000 How to Order C () () () () () () (E) (E) () (E) (E) () () (E) (E) () () (E) (E) () () (E) (E) Type of actuation position single position double
More informationYS Series Contactors YS1N- F11 ****
YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable
More informationVacuum Ejector with Solid State Timer
Vacuum Ejector with Solid State Timer Incorporates solid state timer function for release valve control (Timer setting with PLC is unnecessary) Timing Chart OFF Suction command ON Suction output OFF ON
More informationProcess Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control
Process Series Port For Compressed Air and Air-hydro Circuit Control Exclusively for air pressure system and air-hydro circuit control Universal Port Cylinder actuation by external air he balance poppet
More informationNote) Rated flow (l/min (ANR)) Port size 1 8, , , , , 1 1, , 2
Mist Separator Series ohs Can remove oil mist in compressed air and separate and remove particles such as rust or carbon of more than 0.3 µm. Modular connection is possible with 150C to 550C. (For details,
More informationSignaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12
Presentation Presentation The monolithic indicator banks in the Harmony XVC range are designed for long distance indication of the operating states or sequences of a machine or installation, either visually
More informationPressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature
MEMS Mass Flow Sensor D6F-P A Compact, High-performance Flow Sensor with Dust Segregation Structure. Built in Dust Segregation System (DSS) with cyclone flow structure, diverts particulates from sensor
More informationThermal-Magnetic Circuit Breaker 201/-WA
Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring
More informationSeries SY3000/5000 How to Order Manifold
Type N ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN Rail Mounted/Connector ox SY/ How to Order Manifold SSY SY SY Specifications Symbol Specifications With connector box (COM spec.) N With
More informationMulti-function. Mono-function 1 NO (SPST-NO)
Features Range of electronic staircase timers 17.5 mm wide Time setting from 30 s to 20 min Zero crossing load switching Switch-off early warning - model 14.01 Suitable for 3 or 4 wire systems, with automatic
More informationSeries SY3000/5000/7000
Type1P Type2P 5 Port Solenoid Valve ase Mounted Manifold ar Stock Type/Flat Ribbon Cable Series /5000/000 How to Order Manifold Type 1P/Compact style SS5Y 5 1P 05 C8 Manifold series 3 5, port size Thread
More information2-Color Display Digital Pressure Switch
-Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The
More informationSA1W: Water Detection Sensors
Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com The SA1W is the fastest, most reliable
More informationParallel Style Air Gripper: Wide Type
Parallel Style Air Gripper: Wide Type Series MHL Built-in dust-protection mechanism A scraper with a dust lip is adopted for all rod rotating parts. A large amount of gripping force is provided through
More informationInformation. Model LEYG16 LEYG25 LEYG32
Information A rod type with guide newly added! Compatible with slide-bearing and ball-bushing bearing. Compatible with moment load and stopper (slide bearing). Speed control/positioning: ax. points Positioning
More informationHow to Order BS B. Nil. Bracket (End bracket, Center bracket) Nil
Ionizer / with surface potential sensor Series IZS0 How to Order 00 0 00 00 Ionizer IZ S 0 0 Bar length Bar length 00 mm 0 mm mm 00 mm 00 mm Ionizer Made to Order Bar type Size Electrode needle material
More informationFlow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)
Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable
More informationSpace-saving installation Flexible motor mounting
Space-saving installation Flexible motor mounting compatible!! Pulse train input compatible Automatic actuator recognition Addition of new controller compatible with pulse trains Enables current position
More informationGuide Table. Series MGF
Guide Table Series MGF ø, ø, ø0 Low-profile compact cylinder utilizes a large concentric guiding sleeve to provide excellent eccentric load resistance. Mounting height greatly reduced Low-profile cylinder
More informationFree Mount Cylinder for Vacuum
Free Mount Cylinder for Vacuum Series A free mount cylinder with a vacuum passage in the rod to meet the requirements for Air cylinder + Vacuum pad. A vacuum passage has been provided in the rod of the
More informationHEAVY DUTY POWER RELAYS FEATURES
VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for
More informationVSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter
Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features
More informationDoor Interlock Switches
HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x x 46 mm) Four contacts Gold-plated contacts
More informationWedge Cam Operation Slide Guide. Air Gripper/2-Finger Type ø12, ø16, ø20, ø25. Option: Stainless steel
Wedge Cam Operation Slide Guide Air Gripper/2-inger Type ø2, ø, ø, ø2 MH MH oad Resistant, Dust Cover for Adverse Environments 2 types of finger materials types of dust cover materials Standard: Carbon
More informationZWD100PAF Series Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More informationZWD225PAF Series Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.
More informationSpecifications Valve. Construction. Component Parts No. 1. Description. Body. Knob. Cover Cam ring Stem Spring guide Spring Seal O-ring Valve Cassette
Finger Valve Series VHK ohs Large effective area:.0 to 7.5 mm Small knob operating force: 0.04 to 0.4 N m Poppet valve construction seldom suffers seal defection. The series begins with the min. tubing
More informationDigital Flow Switch for Deionized Water and Chemicals
Digital Flow Switch for Deionized Water and Chemicals Series PFD A single controller can monitor the flow rate of different sensors. Body and New PFA Tube Super PFA Three types of flow range 0. to l/min
More informationSolid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations
Solid State Relays G3RV Slimmest OMRON plug-in SSR with maximum width 6.2 mm Long electrical life and high speed switching Large plug-in terminals for reliable connection G3RV-D (DC load) models can manage
More informationRelated vacuum products
Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter
More informationELECTRICAL SOLUTIONS
Ties Type FL Flexible Material: Flexible Polypropylene UL Recognized continuous use temperature: 149 F (65 C) H W UL 94 flammability rating of V-2 Factory applied adhesive tape provided for easy mounting
More informationHWS 15A-150A Series. Instruction Manual
Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.
More informationZWD100PAF. Conformity to RoHS Directive
-SERIES Dual Output W - 225W Features 15 Complies the standard of the harmonics current limiter Worldwide input: 85-265VAC Peak load accommodatable double power: Approximately twice the value of average
More informationImpulse Lubricator. Standard Specifications
Series 00/10 Intermittent discharge of small, constant amounts to the sliding parts Directly supplies a constant amount of oil just before the lubrication point Standard Specifications Model 1/8 (A) 1.0
More informationTHT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER
INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER THT-500-A/R No.THT51E1 2017.12 Thank you for purchasing our THT-500-A/R, Temperature and Humidity Transmitter (mounted within control panel). This
More informationCorrection Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.
PRODUCT NEWS Correction Reissue Product Discontinuation Notices Proximity Sensors Issue Date August 4, 2014 No. 2014038CE(3) Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.
More informationTecnopoint srl Tel Fax
Tecnopoint srl Tel 041-46086 Fax 041-46684 info@tecnopointonline.it http://www.tecnopointonline.it 141 Electric Actuators (SimplifiedOptions) Electric Cylinders: LZ e-rodless Actuator: E-MY2 Short Stroke
More informationAdjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global
3 Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.549~ guide... P.3~ General precautions... P.55~ PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global
More informationHour Meter Series HM36
Robust design with high degree of Accuracy and Compact size Frequency independent for AC applications Indicates operating time in hours and tenths with running indicators Totally sealed from Dust and Moisture
More informationLow Profile Air Gripper
Low Profile Air Gripper Series MHF2 MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHW -X Low profile air gripper with space-saving design MRHQ MA D- Courtesy of Steven ngineering, Inc.-2 Ryan Way, South San Francisco,
More informationGateway System Serial Transmission System
Gateway System Series 00 I compliant V S000 C Tie-rod base Z pplicable series Cassette base manifold 000/000 Tie-rod base manifold 000/000/000/000 Number of output points: points Connected to the 00GW
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationFilterpack FR-BFP2-(H)0.4K to (H)15K
INVERTER INSTRUCTION MANUAL FR-BFP2-(H)0.4K to (H)15K 1. Product Checking... 1 2. Applicable Inverter... 1 3. Installation... 2 3.1 Inverter Installation (installation of the )...2 4. Wiring... 4 5. Main
More informationAZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking
HM-6244-3 OPERATING MANUAL Closed Loop Stepping and Driver Package AZ Series Introduction Before use Only qualified personnel should work with the product. Use the product correctly after thoroughly reading
More informationRY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz
Miniature Magnetic Latching Key features of the RY2L series include: Standard ice cube, 14-pin solder lug termination Operates by pulse input and maintains condition even during power failure Coils rated
More informationNumber of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures
us enclosures G. us enclosures Enclosure:.38 Door:.5 IP 65 to EN 60 59/09.00, complies with NEMA. Door with l/h hinge, cam lock with double-bit insert, () support rail(s) S 35/7.5 (for G 586.). Drilled
More informationVacuum pump system type
type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated
More informationModel Number Structure
Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved
More information2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _
Diameter mm Shaft Type/Hollow Type/Built-In Type Incremental Rotary Encoder Features Diameter mm flange type Suitable for measuring angle, position, revolution, speed, acceleration and distance Power supply:
More information/ LOSSNAY / LGH-RS2-E2
2 Indoor units / / LGH-RS2-E2 unit CONTENTS LGH-RS2-E2. LGH-5RS2-E2 48 2. LGH-25RS2-E2 49. LGH-5RS2-E2 44 4. LGH-5RS2-E2 44 5. LGH-8RS2-E2 442 6. LGH-RS2-E2 7. LGH-5RS2-E2 8. LGH-2RS2-E2 44 444 445 9.
More informationDPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION
Sensor INSTRUCTI MANUAL Head Separated Digital Sensor Controller DPC-1 Series MJE-DPC1 No.7-98V Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly
More informationFeatures. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)
817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global
More informationI N D E X. VQ1000 How to Order, Manifold Options VQ2000 How to Order, Manifold Options VQ1000/2000 Model, Standard/Manifold Specifications
I N D E VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold Options VQ000/000 Model, Standard/Manifold Specifications VQ000/000 F (D-sub connector) VQ000/000 (Flat ribbon cable) VQ000/000
More informationEMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com
EMUJC Series Electronic actuator Technical Data Sheet WattsIndustries.com Description Watts Water Technologies, Inc. The actuator EMUJC Series is an electronic device with 3-point or proportional control
More information5 Port Solenoid Valve
0 PW COM Rubber Seal Port Solenoid Valve Series SZ000 Cassette Type Manifold The plug-in cassette system makes valve replacement easy. plug-in manifold has been created with a height of. mm (including
More informationExample. U side. Stations SY5000
45 Type 5 ort Solenoid Valve ase Mounted Manifold Stacking Type/DIN ail Mounted/Individual Wiring Series SY3000/5000 How to Order Manifold How to Order Manifold ssembly (Example) SS5Y 3 45 05 U C6 Example
More informationOiltight Switches & Pilot Devices
Oiltight Non-Illuminated ushbuttons (Sub-Assembled) Contact Block + Operator + Button = Completed Unit art Numbers: Operators Style art Number Momentary Maintained LW1B-M0 LW1B-A0 LW2B-M0 LW2B-A0 Mushroom
More informationSeries VP3145/3165/3185
Large Size 3 Port Solenoid Valve Series VP345/365/385 Rubber Seal Large flow capacity, small exhaust resistance (Refer to Flow Characteristic table.) Easy conversion to N.C. or N.O. Function plate makes
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More information(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2
Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.
More informationMiniature Fittings Stainless Steel 316. Hose nipple. Barb Configuration for easy insertion into the tube Holds the tube tightly.
Miniature Fittings Stainless Steel 316 Series MS Applicable Tubes: ø3.2, ø4, ø6 Connection Thread:, R 1/ For use in corrosive environments Compact piping space Tube has a large retaining force. Hose nipple
More informationPressure Gauge Guide
ourtesy of Steven Engineering, Inc.-230 yan Way, South San Francisco, A 900-6370-Main Office: (650) 5-9200- Local Area: (00) 25-9200-www.stevenengineering.com Gauge for General Purpose With limit indicator
More informationTactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.
Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications)
More informationE2K-L. Liquid Level Sensor. Applications. Ordering Information
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 MPa Pilot Operated / Port Solenoid Valve & Check Valve Series VCH VCH4/4: Port VCH40: Port VCHC40: Check Valve Pilot Operated Port Solenoid Valve Series VCH40 Stable responsiveness Response time dispersion
More informationIonizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.
Ionizer 2 types of sensors are available. Rapid elimination of static electricity by a feedback sensor Continuously emits ions in accordance with the detected polarity of a workpiece. Supply pressure:
More informationSlim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations
Slim Relay G3RV The World's First Industrial Slim Relay G2RV compatible LED indicator built in SSR Push-in terminals and accessories for easy wiring. Model Number Structure Model Number Legend G3RV-SL
More informationSuppression Products. Overvoltage Suppression Products: Introduction Industrial Varistor Products 173
: Introduction 171-172 Industrial aristor Products 173 Surge Fuses 174 www.littelfuse.com 2005 Littelfuse POWR-GAR Products Catalog Courtesy of Steven ngineering, Inc.-230 Ryan Way, South San Francisco,
More informationSolenoid coil for control in potentially explosive areas Type BZ
Data sheet Solenoid coil for control in potentially explosive areas Type BZ BZ is a solenoid coil with ATEX / IECEx approval, applicable for zone 1 and 2 Ex environments. The coils are designed to be used
More informationDC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual
DC power supply connect to VF-AS1/PS1 Optional initial charger Instruction manual NOTE 1. Make sure that this instruction manual is delivered to the end user of the optional initial charger. 2. Read this
More informationRated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)
SRPH1 Series Single Phase, Analog Input Type SSR Features Power control/ Cycle control/phase control (fixed cycle/ variable cycle) are available with 4-mA analog input Superior dielectric strength : 4,000VAC
More informationMini Free Mount Cylinder
Mini Free Mount Cylinder ø, ø, ø, ø, ø, ø1, ø Series CUJ Added ø, ø1, ø bore sizes. Action Double acting Single acting, spring return Double acting Single acting, spring return Double acting Single acting,
More informationGeneral-Purpose AC Servo MELSERVO-J4 Series Power Regeneration Converter Unit MR-CV_ SSCNET III/H Compatible Drive Unit MR-J4-DU_B_(-RJ)
General-Purpose AC Servo MELSERVO-J4 Series Power Regeneration Converter Unit MR-CV_ SSCNET III/H Compatible Drive Unit MR-J4-DU_B_(-RJ) January, 2017 New Product Release SV1701-3E 3-phase power supply
More informationSuper fast 1 ms Convenient intermediate cable with connector A total of 10 head variations
SERIES Digital Sensor Digital Automatic sensitivity setting Auto reference With analog output /, sec. The fastest response in the industry DP DP Conforming to EMC Directive UL Recognition Super fast ms
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Rated voltage Body
More informationBrushless DC Axial Fans
Brushless DC Axial Fans General Specifications Material: Body PBT UL 9V- Fan PBT UL 9V- Insulation Class E Approvals UL, cul Recognized E89 Box Count: x 8 pieces x pieces 9 x pieces 8 x pieces x pieces
More informationSeries VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4
Type of actuation 4 Piping 0 Side ported Bottom ported 4 Without sub-plate Large Size 5 Port Solenoid Valve Rubber Seal Series 50/4 70 Series VP 5 port solenoid valve 5 7 position single position double
More informationFigure 1: WPR2 Dimensions and Hardware
Installation and Operation Instructions WPR2 Series (Max. Line Pressure < 300 PSI) Wet to Wet Differential Pressure Ø0.200" 2.60" 4.47" 5.47" 5.28" 3.00" Precautions Figure 1: WPR2 Dimensions and Hardware
More informationSeries VQ Port Solenoid Valve
Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors
More informationHigh-power Solid State Relays G3PH
New Product News High-power Solid State Relays G3PH High-power, Load-control s with High Current of 75 or 150 A and High Voltage of 240 or 480 VAC RoHS compliant. Models also available with no zero cross.
More informationAC/DC2-wire Type Cylindrical Proximity Switches
AC/DC2-wire Type Cylindrical Proximity Switches FL7M Series No-polarity 2-wire general-purpose switches are easy to use. 2-wire type for both AC and DC greatly reduces wiring man-hours Stable sensing area
More informationCX-SERIES ADVANCED BATTERY CHARGER
CX-SERIES ADVANCED BATTERY CHARGER Table of Content 1. IMPORTANT SAFETY INFORMATION... 2 1-1 General Safety Precautions... 2 1-2 Battery Precautions... 2 2. FEATURES... 3 2-1 Battery Charging Curve...
More informationLocking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG
Locking Style Spring or Solenoid Locking Two locking mechanisms are available: spring lock with energized solenoid release and energized solenoid lock with spring release. Rigid and flexible in-line actuators
More informationEnergysaving. (10 mm) 3.09 inch (78.5 mm) Silencer (Built-in)
Compact acuum Unit Ejector/acuum Pump System Quick response Compact/ Lightweight Response time of the : 5 ms acuum response time: 28 ms (Shortened by 25%; Comparison with other SMC products) Conditions:
More informationSeries VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.
Port Solenoid Valve Body Ported Series 000 For details about certified products conforming to international standards, visit us at www.smcworld.com. Type of actuation Type of actuation Body option Body
More informationSafety Precautions. Safety Precautions for
E5@N in this catalog have been discontinued at the end of March 2017. Safety Precautions for E5@N/E5@N-H/E5@N-HT Safety Precautions for E5@N/E5@N-H/E5@N-HT Safety Precautions Refer to Safety Precautions
More informationHigh-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.
Tactile Switch BW Tactile Switch with Sealed Construction for Automatic Soldering Sealed construction conforming to IP67 (IEC-6059) provides high reliability in locations exposed to dust or water. Available
More information