Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

Size: px
Start display at page:

Download "Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations"

Transcription

1 SERIES Digital Sensor Digital Automatic sensitivity setting Auto reference With analog output /, sec. The fastest response in the industry DP DP Conforming to EMC Directive UL Recognition Super fast ms Convenient intermediate cable with connector A total of head variations Mounting the detachable head close to the detecting section minimizes piping and enables response time of ms, the fastest in the industry, as well as greatly decreasing tact time delay. In addition, the ultra-small and lightweight design of the head means it can easily be mounted on moving sections. Independent use of sensor head possible Data can be controlled by taking the analog voltage output ( to V) from the sensor head and feeding it to a digital panel meter. Intermediate cable with connector for connecting the sensor head and the controller makes operation and maintenance easier. Standard or flexible intermediate cables are available in m 6.6 ft, m 9.8 ft, and m 6. ft types. Use the flexible intermediate cable when the sensor head is attached to moving sections. A total of head variations to meet all production demands. Vacuum pressure type ( to. kpa) M male thread R (PT) /8 male thread / M female thread NPT /8 male thread / -UNF female thread -UNF male thread Positive pressure type ( to. MPa) M female thread R (PT) /8 male thread / M female thread NPT /8 male thread / -UNF female thread Compound pressure type (. to. kpa) M female thread R (PT) /8 male thread / M female thread NPT /8 male thread / -UNF female thread Sensor head with operation indicator Easy mounting, mobile pressure port The sensor head is also equipped with operation indicator. Output / can be checked on the sensor head, so that it is suitable for checking operation at the suction head. (Linked to Output ) The head s pressure port can be rotated independently (free-turning) of the sensor head. In addition to being easy to mount, the cable can be laid in any direction. Globally usable Two types of output, NPN and PNP, are available to allow use of the sensors anywhere in the world. The sensor, of course, conforms to the CE marking EMC Directive. Further, it has obtained UL recognition. Operation indicator (Orange) Conforming to EMC Directive UL Recognition 76 Phone: Fax: Web: info@clrwtr.com

2 Light-weight, compact design The controller was designed to be light-weight and compact. Control panel setup is low cost and requires minimal space. Sensor head auto-recognition The head s auto-recognition function means you don t have to manually set the head type at the controller, saving you valuable time. User friendly two-color digital display The user friendly two-color digital display changes color when output changes ( / ), making it easy to check operation status at a glance. The display color can be linked to Output or Output. Two independent outputs plus analog voltage output In addition to two independent outputs ( / ), analog voltage output ( to V) is also available. The different outputs allow you to create solutions for a wide variety of applications. Two operation indicators There are two operation indicators that light respectively when Output or Output is. They are convenient for intensive operation checks. Lights up in conjunction with comparative output Lights up in conjunction with comparative output PRESSURE SENSORS Supplied with a panel mounting bracket A panel mounting bracket (MS-DP-) is enclosed to enable simple mounting of the controller onto the panel surface, thus contributing to the total cost reduction. Since the panel thickness can be from to 6 mm.9 to.6 in, the controller can even be mounted on thick, resin-made panels. The attached panel mounting bracket enables vertical installation. types of sensor mounting brackets are available Using the vertical mounting bracket (MS-DP-) and the horizontal mounting bracket (MS-DP-), the devices can be installed in the space inside machines or boxes. MS-DP- for vertical orientation mounting Installed oriented upwards DIN rail mounting bracket is available The controller can be mounted even on a mm.78 in width DIN rail by using the optional DIN rail mounting bracket (MS-DP-). It can be fitted even in a narrow space inside your equipment because it can be mounted from four directions. DP DP Installed oriented downwards MS-DP- for horizontal orientation mounting Installed oriented to the left Made for horizontal panel mounting Using the horizontal multiple panel mounting bracket, the MS-DP- (optional), direct panel surface horizontal mounting is rendered possible. For installation, the panel thickness must be from to 6 mm.9 to.6 in. Installed oriented to the right MS-DP- Phone: Fax: Web: info@clrwtr.com 76

3 DP DP The only sensor in the industry with a leak test mode Four output modes give you complete control. Leak test mode It is suitable for a leak test since Output can be set to the hysteresis mode and Output can be set to the window comparator mode. Using it along with the auto-reference / remote zero-adjustment functions ensures a reliable leak test. Set Value Set Value Set Value Set Value Output Output mh, H: Hysteresis H H: digit or more H: digit H H: digits or more when using psi unit H ( H: digits when using psi unit (Filling pressure detection) (Leak detection) ( Hysteresis mode The hysteresis of the comparative outputs can be set arbitrarily by the set values for / control. Window comparator mode The comparative output can be turned or by a pressure which is within the set pressure range. Forced output mode The comparative outputs are forcibly maintained at level in the sensing mode, irrespective of the set values. Hence, it is convenient for only displaying the pressure value without using the comparative outputs. Further, since the comparative outputs can be forcibly switched or with operation, without actually applying pressure, this mode is suitable for an operation check or a start-up check. Set value Set value Set value Set value Output Output Set value Set value Set value Set value Output Output Output Output Sensing mode Press mh: Hysteresis H H: digit or more H digits or more when using psi unit H H H H mh: Hysteresis Forced output mode Press H: digit digits when using psi unit Sensing mode Equipped with auto-reference and remote zero-adjustment functions If the reference pressure of the equipment changes, the auto-reference function can compensate the threshold levels by the amount of change and the remote zeroadjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are desired. Example: When leak test mode is applied, Output detects the filling pressure and Output detects the leakage. Without auto-reference and remote zero-adjustment functions Mode: Leak test mode Output (Set value: lower limit / upper limit ) Output (Set value: lower limit / upper limit ) Fixed setting Time Variation in the filling pressure Leak threshold level Fail? OK Filling pressure detection Fail? Trial Trial Trial Because the threshold is fixed for conventional pressure sensors, changes in the reference pressure result in wrong decisions. With auto-reference function applied Output (Set value: lower limit / upper limit ) Output (Set value: lower limit / upper limit ) Sets the absolute threshold level With remote zero-adjustment function applied Output (Set value: lower limit / upper limit ) Output (Set value: lower limit / upper limit ) Sets the absolute threshold level Auto-reference input Trial Threshold level after applying auto-reference input Filling pressure detection The display remains at and only the threshold level is changed. Threshold level before applying auto-reference input Auto-reference input value Time When auto-reference input is applied, the reference pressure is added to the threshold level. If the reference pressure changes to or, the auto-reference input compensates for this every time by changing the threshold level, so any variation in the filling pressure can be ignored. OK 766 Phone: Fax: Web: info@clrwtr.com Remote zero--adjustment input Threshold level before applying remote zero-adjustment input Time Trial Threshold level after applying remote zero-adjustment input Filling pressure detection OK The display is forced to, and only the filling pressure drop range is displayed. Displayed when remote zero-adjustment input is applied When remote zero-adjustment input is applied, the reference pressure is forced to. If the reference pressure changes to or, the remote zero-adjustment input adjusts the reference pressure to every time the reference pressure changes, so any variation in the filling pressure can be ignored.

4 ORDER GUIDE configuration diagram Sensor head Intermediate cable PRESSURE SENSORS Controller 6-core cable with connector Only the connector is attached ( ) with the controller. Sensor head An intermediate cable is required to connect the controller and the sensor head. Please order it separately. Type Appearance Rated pressure range (Note) Model No. port Applicable fluid DPH-A M male thread Vacuum pressure Positive pressure Compound pressure to. kpa to. MPa. to. kpa DPH-A DPH-A DPH-A DPH-A DPH-A DPH-A DPH-A7 DPH-A7 DPH-A7 R (PT) /8 male thread / M female thread NPT /8 male thread / -UNF female thread -UNF male thread M male thread R (PT) /8 male thread / M female thread NPT /8 male thread / -UNF female thread M male thread R (PT) /8 male thread / M female thread NPT /8 male thread / -UNF female thread Non-corrosive gas DP DP Note: The rated pressure range indicates the range for full product performance. Controller An intermediate cable is required to connect the controller and the sensor head. Please order it separately. Appearance Rated pressure range (Note) Model No. Output Vacuum pressure: to. kpa Positive pressure: to. MPa Compound pressure:. to. kpa Note: The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. -C -C-P NPN open-collector transistor PNP open-collector transistor Intermediate cable An intermediate cable is required to connect the controller and the sensor head. Please order it separately. Designation Appearance Model No. Description DPH-CC Length: m 6.6 ft Intermediate cable Standard Flexible DPH-CC DPH-CC DPH-CC-R DPH-CC-R Length: m 9.8 ft Length: m 6. ft Length: m 6.6 ft Length: m 9.8 ft -core cable with connector at both ends -core flexible cable with connector at both ends DPH-CC-R Length: m 6. ft Phone: Fax: Web: info@clrwtr.com 767

5 ORDER GUIDE Accessory MS-DP- (Panel mounting bracket) DP DP OPTIS Designation Model No. Description Connector 6-core cable with connector DIN rail mounting bracket Controller mounting bracket Horizontal multiple panel mounting bracket CN-66 CN-66-C CN-66-C MS-DP- MS-DP- MS-DP- MS-DP- Set of housings and 6 connector pins Length: m 6.6 ft. mm 6-core cabtyre cable with connector Length: m 6. ft Cable outer diameter: ".8 mm ".89 in For installation to mm.78 in width DIN rail Vertical mounting bracket Horizontal mounting bracket Enables the sensors to be attached to each other laterally and mounted on the panel. Connector CN-66 Connector pin Housing DIN rail mounting bracket MS-DP- 6-core cable with connector CN-66-C CN-66-C Controller mounting bracket MS-DP- MS-DP- Label space Designed with a 9 mm. in label space to enable the labeling of the sensors with a label printer (9 mm. in width) for sensor number and application data. Horizontal multiple panel mounting bracket MS-DP- Panel fixing screw (Accesory) MS-DP- m The above illustration shows two units connected in sequence. 768 Phone: Fax: Web: info@clrwtr.com

6 SCIFICATIS sensor head Type Item Model No. Type of pressure Rated pressure range (Note) withstandability Vacuum pressure Positive pressure Compound pressure kpa type MPa type kpa type DPH-A DPH-A DPH-A DPH-A DPH-A DPH-A DPH-A DPH-A7 DPH-A7 DPH-A7 Gauge pressure to. kpa to. MPa. to. kpa kpa. MPa kpa PRESSURE SENSORS Applicable fluid Supply voltage Current consumption Analog voltage output Pollution degree Environmental resistance Protection Ambient temperature Ambient humidity EMC Voltage withstandability Insulation resistance Vibration resistance Shock resistance Non-corrosive gas to V DC % Ripple P-P % or less ma or less (operation indicator off) / 7 ma or less (operation indicator on) Output voltage: to V (over rated pressure range) Zero point: within V % F.S. (vacuum / positive pressure type) within V % F.S. (compound pressure type) Span: within V. % F.S. Linearity: within % F.S. Output impedance: kω approx. (Industrial environment) IP (IEC) to C to F (No dew condensation), Storage: to 6 C to F to 8 % RH, Storage: to 8 % RH EN 8-, EN 8-, EN 6-6-, V AC for one min. between all supply terminals connected together and enclosure MΩ, or more, with V DC megger between all supply terminals connected together and enclosure to Hz frequency, mm.8 in amplitude, or G in X, Y and Z directions for two hours each, m/s acceleration ( G approx.) in X, Y and Z directions for three times each Output voltage (V) High pressure (positive / compound pressure type) High vacuum (vacuum pressure type) DP DP Operation indicator Orange LED [lights up when Output is (only in case of connection to the series pressure controller)] Temperature characteristics Voltage characteristics port Material Over ambient temperature range to C to F: within % F.S. of detected pressure at C 77 F Over ambient temperature range to C to F: within % F.S. of detected pressure at C 77 F Within. % F.S. for % fluctuation of the supply voltage DPH-A : M male thread (for installing gasket), DPH-A : R (PT) /8 male thread / M female thread DPH-A : NPT /8 male thread / -UNF female thread, DPH-A: -UNF male thread (for installing gasket) Enclosure: PBT, port: Brass (nickel plated) [however, stainless steel (SUS) in case of DPH-A ] Connecting method Cable Cable extension Weight Accessories Connector. mm -core oil resistant cabtyre cable with connector, mm.97 in long Extension up to total m.88 ft is possible with. mm, or more, cable. DPH-A / DPH-A: 6 g approx., DPH-A / DPH-A : g approx. Gasket (DPH-A, DPH-A only) Notes: ) The rated pressure range indicates the range for full product performance. Notes: ) The pressure sensor head can be used independently. Phone: Fax: Web: info@clrwtr.com 769

7 DP DP SCIFICATIS sensor controller Type Item Model No. Applicable pressure sensor head Rated pressure range (Note ) DPH-A, DPH-A, DPH-A7, DPH-A, DPH-A, DPH-A7, DPH-A, DPH-A, DPH-A7, DPH-A Vacuum pressure: to. kpa, Positive pressure: to. MPa, Compound pressure:. to. kpa Vacuum pressure:. to. kpa (. to. kgf/cm,.7 to.7 psi,. to. bar, 76 to 76 mmhg, 9.9 to 9.9 inhg) Set pressure range (Note ) Positive pressure:. to. MPa (.7 to.7 kgf/cm,. to. psi,. to. bar) Compound pressure: 99.9 to 99.9 kpa (.999 to.999 kgf/cm, 9.98 to 9.98 psi,.999 to.999 bar, to 7 mmhg, 9. to 6. inhg) Supply voltage / Current consumption to V DC % Ripple P-P % or less / 6 ma or less (not including pressure sensor head) Sensor supply voltage Same as supply voltage output Output Output ( ) Input Utilization category Output operation Output modes Hysteresis Repeatability Response time Short-circuit protection sensor head input Auto-reference / Remote zero-adjustment input Analog voltage output Display Displayable pressure range Operation display Analog bar display Operation indicator Pollution degree Protection Ambient temperature Ambient humidity EMC Voltage withstandability Insulation resistance Vibration resistance Shock resistance Temperature characteristics Material Connecting method Conductor cross-section area (Note ) Lead wire diameter Wire material Cable extension Weight Accessories Environmental resistance Suitable cable NPN output type -C NPN open-collector transistor ( outputs) Maximum sink current: ma Applied voltage: V DC or less (between comparative output and V) Residual voltage: V or less (at ma sink current). V or less (at 6 ma sink current) DC- or DC- NO / NC, selectable by operation Equipped with types of modes: hysteresis mode, window comparator mode, leak test mode, forced output mode (selectable by operation) digit (however, variable in hysteresis mode, variable for Output only when using leak test mode) With vacuum / positive pressure type sensor head: within. % F.S. digit ( digits) With compound pressure type sensor head: within. % F.S. digits ( 6 digits) ms, 6 ms, 8 ms, ms or less, selectable by operation (however, set response time is ms when auto-reference / remote zero-adjustment input is applied) Input condition: NPN non-contact input [operates in Low (fall) state] Signal condition: High... to V, or open Low... V or less Low level input time... ms or more Output voltage: to V DC (over rated pressure range) Zero point: within V. % F.S. (vacuum / positive pressure type) within V. % F.S. (compound pressure) Span: within V % F.S. Linearity: within % F.S. Output impedance: kω approx. Incorporated Input voltage range: to V DC (over rated pressure range) PNP output type -C-P PNP open-collector transistor ( outputs) Maximum source current: ma Applied voltage: Same as supply voltage (between comparative output and V) Residual voltage: V or less (at ma source current) Input condition: PNP non-contact input [operates in High (rise) state] Signal condition: High... to V Low... V or less, or open High level input time... ms or more / digit LCD display (with red and green backlight) (Display refresh rate: 6 ms, ms or, ms selectable by operation) Vacuum pressure:. to. kpa (. to. kgf/cm,.7 to.7 psi,. to. bar, 8 to 76 mmhg,. to 9.9 inhg) Positive pressure:. to. MPa (. to.7 kgf/cm, 7. to. psi,. to. bar) Compound pressure:. to. kpa (. to.7 kgf/cm,.7 to. psi,. to. bar, 76 to 787 mmhg, 9.9 to. inhg) LCD segment is red when the comparative output is, and green when it is (output is selected via supplementary settings) Bar display in steps of % F.S. approx. Orange LED (lights up when Output is ), Green LED (lights up when Output is ) (Industrial environment) IP (IEC) to C to F (No dew condensation), Storage: to 6 C to F to 8 % RH, Storage: to 8 % RH EN 8-, EN 8-, EN 6-6-, V AC for one min. between all supply terminals connected together and enclosure MΩ, or more, with V DC megger between all supply terminals connected together and enclosure to Hz frequency,.7 mm. in amplitude, or G in X, Y and Z directions for two hours each m/s acceleration in X, Y and Z directions for three times each Over ambient temperature range to C to F: within. % F.S. of detected pressure at C 77 F (not including pressure sensor head) Front case: ABS, LCD display section: T, Rear case: PBT Connector.6 to. mm (AWG# to #) ". to ".8 mm ".7 to ".7 in Tin plated, soft, twisted copper wire Extension up to total m 8.8 ft (less than m.88 ft when conforming to CE marking) is possible with. mm, or more, cable. g approx. Panel mounting bracket (MS-DP-): set, Connector: set (Housing: pc., Connector pin: 6 pcs.), unit label: set., Connector cap: pc. Output voltage (V) High pressure (positive / compound pressure type) High vacuum (vacuum pressure type) Notes: ) The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. Notes: ) If the wiring is longer than m 6. ft, use a cable with a diameter of. mm or more. Phone: Fax: Web: info@clrwtr.com

8 I/O CIRCUIT AND WIRING DIAGRAMS -C I/O circuit diagram Sensor head main circuit Sensor head internal circuit Intermediate cable NPN output type Terminal No. + V D D Type setting / indicator kω ZD Analog voltage input V Controller main circuit Tr ZD Tr kω ZD ZD Controller internal circuit Symbols D, D: Reverse supply polarity protection diode ZD to ZD: Surge absorption zener diode Tr, Tr: NPN output transistor Pin position Connector for sensor head connection 6 Connector for power supply / I-O cable connection Terminal No. Color code of cable with connector (Brown) + V (Pink) Auto-reference / Remote zero-adjustment input 6 (Gray) Analog voltage output Load (Black) Output (White) ma max. Output ma max. (Blue) V Users circuit Connector for power supply / I-O cable connection V Analog voltage output V Output Output 6 Auto-reference / Remote zero-adjustment input Load + to V DC + % For independent use of Sensor head Main circuit D kω ZD Sensor head internal circuit (Brown) + V (White) Not connected (Note) (Black) Analog voltage output ( to V) (Blue) V Users circuit Note: In case the sensor head is used independently, insulate the white lead wire (terminal No.) and keep it open. Connector for sensor head connection V Analog voltage output V Not connected Terminal No. Color code + to V DC + % Symbols D : Reverse supply polarity protection diode ZD: Surge absorption zener diode PRESSURE SENSORS DP DP -C-P I/O circuit diagram Sensor head main circuit D kω ZD Terminal No. + V PNP output type Terminal No. Color code of cable with connector (Brown) + V Type setting / D (Pink) Auto-reference / indicator Remote zero-adjustment input 6 (Black) Output Analog ma max. ZD voltage Tr input Tr ZD ma max. (White) Load kω Output (Gray) Analog Load voltage output V ZD (Blue) V Controller main circuit + to V DC + % Sensor head internal circuit Intermediate cable Controller internal circuit Users circuit Symbols D, D: Reverse supply polarity protection diode ZD to ZD: Surge absorption zener diode Tr, Tr: NPN output transistor Pin position Connector for sensor head connection 6 Connector for power supply / I-O cable connection Connector for power supply / I-O cable connection V Analog voltage output V Output Output 6 Auto-reference / Remote zero-adjustment input Connector for sensor head connection V Analog voltage output V Not connected Phone: Fax: Web: info@clrwtr.com 77

9 DP DP PRECAUTIS FOR PROR USE 77 This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal pressure detection sensor. The DPH series is designed for use with non-corrosive gas. It cannot be used with liquid or corrosive gas. Operation If setting is impossible even with pressing the, verify whether the -protect function is enabled. Please note that pressing down on the for an extended moment will enable the -protect function as soon as the is released. If using the window comparator mode, set the pressure values so that there is a difference of digits, or more, between Set Value (P-) and Set Value (P-) and between Set Value (P-) and Set Value (P-). Functional description OUT 6 Description / digit LCD display with red and ( green backlight ) Output operation indicator (Orange) Output operation indicator (Green) Increment () Decrement () Connector for power supply / I-O cable connection Connector for sensor head connection 8 Function Displays measured pressure, settings, error messages and -protect status. Its lighting up can be set as Red when / Green when with respect to either Output or Output, according to the backlight relation selection during the supplementary setting mode. Lights up when Output is. Lights up when Output is. In the initial setting mode and supplementary setting mode, pressing the changes the setting item. In the pressure value setting mode, pressing the changes the set value. In the sensing mode, pressing the continuously for sec., or more, displays the peak hold value. In the initial setting mode and supplementary setting mode, pressing the changes the set conditions. In the pressure value setting mode, pressing the changes the set value. In the sensing mode, pressing the continuously for sec., or more, displays the bottom hold value. In the pressure value setting mode, pressing the changes the setting item. In the sensing mode, pressing the continuously for sec., or more, can set / cancel the -protect. In the sensing mode, pressing both and simultaneously changes the mode to the initial setting mode. Whereas, pressing both and simultaneously changes the mode to the supplementary setting mode. It is the connector for connection of power supply / I-O cable. It is the connector for connection of sensor head. 7 In the sensing mode, if both s are simultaneously pressed continuously, zero-point adjustment is done. Error messages When an error occurs, take the following corrective action. Error message Cause Corrective action The controller, sensor head and the intermediate cable are not correctly connected. Sensor head cable or intermediate cable have a cable break. The sensor head is damaged. Overcurrent due to shortcircuit. is being applied during zero-point adjustment. Positive pressure and compound pressure types Vacuum pressure type Positive pressure and compound pressure types Vacuum pressure type Applied pressure exceeds the upper limit of displayable pressure range. Applied pressure exceeds the lower limit (reverse pressure) of displayable pressure range. Applied pressure exceeds the lower limit (reverse pressure) of displayable pressure range. Applied pressure exceeds the upper limit of displayable pressure range. Connect the sensor head and the intermediate cable correctly. Check the sensor head cable and the intermediate cable and replace the cable having a break. Replace the sensor head. Switch off the power supply and check the load. Applied pressure at the pressure port should be brought to atmospheric pressure and zero-point adjustment should be done again. Applied pressure should be brought within the rated pressure range. Wiring Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this controller, connect the frame ground (F.G.) terminal of the equipment to an actual ground. If the used power supply generates a surge, connect a surge absorber to the power supply to absorb the surge. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. In order to reduce noise, make the wiring as short as possible. Take care that wrong wiring will damage the sensor. Conditions in use for CE conformity The controller is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 6-6- (Note) and the following condition must be met to conform to that standard. Condition Cable length between the power supply and the controller should be less than m.88 ft. Note: The EN 8- that previously applied to the products for conforming to EMC Directive was replaced by EN 6-6- starting April st,. Others Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (: sec. approx., DPH: ms approx.) after the power supply is switched on. Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the s with pointed or sharp objects.

10 PRECAUTIS FOR PROR USE Setting If -protect has been set, make sure to release -protect before operating the s. [Please refer to Key-protect function on p.776 for the procedure.] value setting can be done only if the output mode is set to the hysteresis mode, window comparator mode or the leak test mode. values cannot be set if the output mode is set to the forced output mode. Set Values P- to P- can be common for all the output modes. In the positive pressure type and the compound pressure type, Set Value P- can be set only towards the higher pressure side with respect to Set Value P- and Set Value P- can be set only towards the higher pressure side with respect to Set Value P-. Further, in the vacuum pressure type, Set Value P- can be set only towards the higher vacuum side with respect to Set Value P- and Set Value P- can be set only towards the higher vacuum side with respect to Set Value P-. The auto-reference function affects only Set Value P- and Set Value P-. Set Value P-A is the pressure value when the auto-reference input or the remote zero-adjustment input is applied. When the autoreference input or the remote zero-adjustment input is not applied, Set Value P-A is zero. The set conditions are written and stored into an EEPROM. However, note that the EEPROM has a life span and its guaranteed life is, write operation cycles. Further, since the Set Value P-A is not stored in the EEPROM, they are not included in the number of write operation cycles. PRESSURE SENSORS Setting procedure Sensing mode + Zero-adjustment Zero-adjustment NO / NC selection ( ) Press continuously Initial setting mode Output : NO Output : NO Output : NC Output : NO Output : NC Output : NC Output : NO Output : NC Adjust zero point. Release the s when is displayed Sensing mode Display mode, Output mode and Unit are set. Display mode Output mode Unit Digital display Hysteresis mode kpa kgf/cm bar psi Analog display Window comparator mode or MPa Positive pressure type Leak test mode Forced output mode inhg mmhg Vacuum pressure type, compound pressure type Sensing mode Supplementary setting mode NO / NC, Display cycle, Response time, range, Display color relation and Auto-reference / Remote zero-adjustment are set. Display cycle selection ( ) Response time range Display color relation selection ( ) selection ( ) selection ( ) 6 ms ms MPa Output ms, ms 6 ms 8 ms ms, kpa Note: Only when positive type sensor head is connected. Output Auto-reference / Remote zero-adjustment selection ( ) Auto-reference function Remote zeroadjustment function Sensing mode DP DP value setting mode Enter Set Value P- using and. Set Values P- to P- are set. Enter Set Value P- using and. Enter Set Value P- using and. Enter Set Value P- using and. Enter Set Enter Set Enter Set Enter Set Value P- Value P- Value P- Value P- Measured value at the time of auto-reference input / remote zeroadjustment input is displayed. (Initial value is zero.) Display Set Value P-A Sensing mode Phone: Fax: Web: info@clrwtr.com 77

11 DP DP PRECAUTIS FOR PROR USE Auto-reference function Auto-reference function corrects Set Value P- and Set Value P- of Output by taking the pressure measured at the time of auto-reference input as the reference pressure. <Before auto-reference input> Output Atmospheric pressure P- P- When there is no auto-reference input, the atmospheric pressure is taken as the reference pressure for Set Value P- and Set Value P-. <After auto-reference input> Output Auto-reference input change Atmospheric pressure P-A P- P- P- =P-+P-A P- =P-+P-A At the time of auto-reference input, the pressure value detected at that instant is temporarily recorded as Set Value P-A and becomes the reference pressure. With Set Value P-A as the reference pressure, Set Value P- and Set Value P- are automatically corrected to Set Value P- Set Value P-A and Set Value P- Set Value P-A, respectively. Settable range and set pressure range after correction The settable range of Set Value P- and Set Value P- is wider than the rated pressure range to cater to the auto-reference function. At the time of auto-reference input, if the corrected set value exceeds the set pressure range, the set value is automatically corrected to be within the set pressure range. Hence, please see that the set pressure range is not exceeded. Operation chart <Normal operation (comparative outputs set to NO)> Output Output Applied pressure (kpa) Display value (kpa) Set value (kpa) P- P- P- P- <With auto-reference input (comparative outputs set to NO)> Auto-reference input: kpa Output mode: Hysteresis mode Output Output Applied pressure (kpa) Display value (kpa) Set value (kpa) P- P- P-A P- P- 8 9 Note: As in the case of the hysteresis mode, Set Value P- and Set Value P- are shifted also in case the output is set to the window comparator mode or the leak test mode. Maintain the pressure at a constant level for at least ms after the auto-reference input is made Low (High in case of PNP output type). If used in a transient state, it will result in wrong operation. Use Output at least set response time ms after the auto-reference input is made Low (High in case of PNP output type). At the time of auto-reference input, is displayed on the / digit display for sec. approx. The auto-reference input value (Set Value P-A) becomes zero when the power supply is switched off and then on again. Although it is not possible to display the corrected Set Value P- and Set Value P-, it is possible to display the auto-reference input value (Set Value P-A). 77 Phone: Fax: Web: info@clrwtr.com

12 PRECAUTIS FOR PROR USE Remote zero-adjustment function The remote zero-adjustment function forcibly sets the pressure value at the time of application of an external input signal to zero. At the time of remote zero-adjustment input, the set values are not corrected. When using the remote zero-adjustment function, make sure that the pressure and the set values do not exceed the rated pressure range. Operation chart <Normal operation (comparative outputs set to NO)> Output Output Applied pressure (kpa) Display value (kpa) P- P- P- P- Set value (kpa) <With remote zero-adjustment input (comparative outputs set to NO)> Remote zero-adjustment input: kpa Output mode: Hysteresis mode Output Output Applied pressure (kpa) Display value (kpa) Set value (kpa) Remote zero-adjustment input: kpa Output mode: Leak test mode P- P- P- P- Note: As in the case of the hysteresis mode, the displayed values and the / points of the output are shifted also in case the output mode is set to the window comparator mode. Output Output Applied pressure (kpa) Display value (kpa) Set value (kpa) P- P- P- P- Note: In the leak test mode, the zero-adjustment function is applied only to Output. Output operates with the atmospheric pressure as the reference. Maintain the pressure at a constant level for at least ms after the remote zero-adjustment input is made Low (High in case of PNP output type). If used in a transient state, it will result in wrong operation. Use the comparative outputs at least set response time ms after the remote zero-adjustment input is made Low (High in case of PNP output type). At the time of remote zero-adjustment input, is displayed on the / digit display for sec. approx. If the power supply is switched off and then on again, the remote zero-adjustment input value is cleared and the sensor returns to normal operation with atmospheric pressure as the reference. Forced output mode In the initial setting mode, if the output mode is set to the forced output mode ( ), the comparative outputs are forcibly maintained at level in the sensing mode, irrespective of Set Values P- to P-. Further, if the s are operated as per the procedure given below, the comparative outputs can be forcibly switched either or without applying pressure at the pressure port. This is convenient for an operation check of the comparative outputs or for an inspection before commencing work. The diagram below appears when the -C has been used to set the display to Digital display ( ). In the sensing mode, press to change to the forced output mode. Each time is pressed, OUT Output switches to and, alternately. Each time is pressed, Output switches to and, alternately. Press to return to the sensing mode. Output is kept at the point where the mode is changed from another output mode to forced output control mode ( ). Even if output has been set to stay during forced output control mode, it will be forcibly changed to at the point where the mode changes back to sensing mode. Peak hold & bottom hold functions Peak hold and bottom hold functions enable the display of the peak value (maximum pressure value) and the bottom value (minimum pressure value) of the varying measured pressure. These functions are convenient for finding the pressure variation range or determining the reference for pressure settings. Please note that the peak value and the bottom value data is erased when it is no longer displayed. OUT OUT OUT OUT Displayed alternately Displayed alternately Peak hold display In the sensing mode, keep pressed until is displayed. ( sec. or more) When the finger is released after is displayed, the peak value and are displayed alternately. Press. Sensor returns to the sensing mode. If the applied pressure exceeds the displayable pressure range, error message( or ) and are displayed alternately. In this case, bring back the applied pressure to within the rated pressure range. The figure on the left shows the display of a vacuum type sensor. Bottom hold display In the sensing mode, keep pressed until is displayed. ( sec. or more) When the finger is released after is displayed, the bottom value and are displayed alternately. Press. Sensor returns to the sensing mode. If the applied pressure exceeds the displayable pressure range, error message ( or ) and are displayed alternately. In this case, bring back the applied pressure to within the rated pressure range. The figure on the left shows the display of a vacuum type sensor. PRESSURE SENSORS DP DP Phone: Fax: Web: info@clrwtr.com 77

13 PRECAUTIS FOR PROR USE Key-protect function Key-protect is a function which prevents any unintentional change in the conditions which have been entered in each setting mode by making the sensor not to respond to the operations. Setting of -protect OUT In the sensing mode, press continuously for sec., or more, and release it immediately when is displayed. Key-protect is set and the sensor returns to the sensing mode. Since the -protect information is stored in an EEPROM, it is not erased even if the power supply is switched off. Please take care to remember if the -protect function has been set. Connecting To connect the sensor head to the controller, the optional intermediate cable (DPH-CC ) must be used. Take care that stress is not directly applied to the cable joint or the connector. If the sensor head is to be mounted on a movable part, make sure to use a flexible intermediate cable. When connecting the intermediate cable to the controller, make sure to fit the connector cap, supplied as an accessory with the controller, by sliding it as shown in the figure below. If the connector cap is not fitted, there is a danger of the intermediate cable getting disconnected from the sensor. Release of -protect DP DP OUT In the sensing mode, press continuously for sec., or more, and release it immediately when is displayed. Key-protect is released and the sensor returns to the sensing mode. When the s are to be operated, make sure that -protect is released. Piping When connecting a commercial coupling to the pressure port, hold the hexagonal section of the pressure port with a mm. in (DPH-A, DPH-A : mm.7 in) spanner, and make sure that the tightening torque is N m (male thread type of DPH-A, DPH-A : N m) or less. If excessive tightening torque is applied, the M male thread of the commercial coupling or the pressure port will get damaged. Connector cap Mounting Install the enclosed panel mounting bracket (MS-DP-) as shown in the figure below. The tightening torque should be. N m or less. Further, tighten both the right and the left screw gradually and equally, so that the panel mounting bracket does not tilt. M (length mm.9 in) panel fixing screw (Accessory) Panel mounting bracket (MS-DP-) (Accessory) -C -C-P Controller / digit LCD display (Green and Red) Output operation indicator (Orange) OUT.7 Increment (6) (.7) 9. Connector for sensor head connection 6..6 Connector for power supply / I-O cable connection Mode selection Decrement Output operation indicator (Green) Connector cap Phone: Fax: Web: info@clrwtr.com

14 DPH-A DPH-A Sensor head DPH-A DPH-A Sensor head PRESSURE SENSORS port.97 (8.) (.78) DPH-A : M male thread DPH-A: -UNF male thread ".7 ".6 cable () (.) () (.97) port (8.) (.78) () (.) DPH-A : R /8 male thead / M female thead DPH-A : NPT /8 male thead / -UNF female thread () (.9) ".7 ".6 cable Operation indicator (Orange) MS-DP- Assembly dimensions SMR-V-N manufactured by JST Mfg. CO.,LTD. Operation indicator (Orange) Panel mounting bracket (Accessory for the controller) Panel cut-out dimensions SMR-V-N manufactured by JST Mfg. CO.,LTD. 6.6 DP DP (.).9 (.88) OUT Panel fixing screw Material: POM Two M (length mm 9 in) screws for fitting are attached.. X X X when n unit is installed X (n ) 7 mm.669 in Note: The panel thickness should be to 6 mm.9 to.6 in. MS-DP- DIN rail mounting bracket (Optional) Assembly dimensions Vertical mounting Variable range Horizontal mounting -". ".77 mounting holes () (.9).69 Suitable for mm.78 in width DIN rail.787 OUT ". ".77 mounting holes Suitable for mm.78 in width DIN rail Variable range () (.9) OUT

15 DPH-CC Intermediate cable (Optional) (6) ".7 ".6 cable (.6) DF-DS-C manufactured by Hirose Electric CO.,LTD. CN-66 (7.) (.87) L Connector (Optional) (.7) (.6) Note: The heat-shrink tube for the standard cable is black, and the heat-shrink tube for the flexible cable is gray. (.) (.) SMP-V-NC manufactured by JST Mfg. CO.,LTD. CN-66-C CN-66-C Model No. Cable length DPH-CC(-R) m 6.6 ft DPH-CC(-R) m 9.8 ft DPH-CC(-R) m 6. ft Cable with connector (Optional) DP DP Housing (9.) (.7) (7.) (.68) (.) (.9) (6.9) (.7) Connector pin (.9) (.7) (6.) (.6) (.) (.8) Mating Connector Connector pin: BXA-T-P.6 manufactured by JST Mfg. CO., LTD. Housing: XAP-6V- manufactured by JST Mfg. CO., LTD. Crimping tool YC-69R manufactured by JST Mfg. CO., LTD., 78.7 (CN-66-C:, 96.8) XAP-6V- manufactured by JST Mfg. CO.,LTD. ".8 ".89 cable MS-DP- Controller mounting bracket (Optional) MS-DP- Controller mounting bracket (Optional) (.7) (.68) (.8) (.8) (9.) (.7) () (.969) -". ".77 mounting holes t t R6 R ". ".77 mounting holes..77 Material: Cold rolled carbon steel (SPCC)(Uni-chrome plated) t t.79 Note: Use together with panel mounting bracket (MS-DP-) included with controller. Material: Cold rolled carbon steel (SPCC)(Uni-chrome plated) Note: Use together with panel mounting bracket (MS-DP-) included with controller. MS-DP- Horizontal multiple panel mounting bracket (Optional) Assembly dimensions Panel cut-out dimensions X X or more X when n unit is installed X (n ) 7 mm.7 in (n or less) When installed laterally in sequence When installing individually Note: The panel thickness should be to 6 mm.9 to.6 in. Applicable panel thickness dimensions t to 6 mm t.9 to.6 in Panel fixing screw

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES

DP5/DPH. Head Separated Digital Pressure Sensor. 1/1000 Second High-Speed Response. The advantage of the fastest response in the industry SERIES Head Separated Digital Pressure Sensor SERIES /000 Second High-Speed Response Conforming to EMC Directive UL Recognition /,000 sec. The advantage of the fastest response in the industry 55 High speed in

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

Digital Pressure Sensor with Auto-reference Function. Example of air-leak test. Threshold level. Reference pressure. Reference pressure

Digital Pressure Sensor with Auto-reference Function. Example of air-leak test. Threshold level. Reference pressure. Reference pressure SERIES Digital ure Sensor with Auto-reference Function Digital Auto reference High accuracy sensing at all times with autoreference function * UL 61010C-1 compatible, Passed the UL 991 Environment Test

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor PE DP-M DP-Y DP3 High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response time at a high resolution of 1/1,000. It enables highly accurate

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor Complete Functionality from a Wide Model Line-up Marked Conforming to EMC Directive High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response

More information

2 Window comparator mode. Hysteresis Hysteresis

2 Window comparator mode. Hysteresis Hysteresis SERIES High-performance Digital Pressure Sensor Digital Automatic sensitivity setting With analog output Complete functionality! Selection from a wide lineup DP3 * UL 61010C-1 compatible, Passed the UL

More information

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level. SERIES LED Bar Display Mechanical Switch is Out of Date Choose the Contemporary Pressure Sensor with LED Bar Display Marked Conforming to EMC directive Bright LED Bar Display Easy to read the pressure

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

A New Global Standard

A New Global Standard PRESSURE SENSOR DIGITAL PRESSURE SENSOR DP- SERIES Conforming to EMC Directive Recognition Certification [DP-(A)/(A) only] A New Global Standard Dual display for the digital pressure sensors of the future

More information

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION

DPC-100 Series INSTRUCTION MANUAL WIRING I/O CIRCUIT DIAGRAMS PART DESCRIPTION Sensor INSTRUCTI MANUAL Head Separated Digital Sensor Controller DPC-1 Series MJE-DPC1 No.7-98V Thank you very much for using SUNX products. Please read this Instruction Manual carefully and thoroughly

More information

Not affected by drops, bubbles or froth

Not affected by drops, bubbles or froth PARTICULAR USE SENSORS SERIES Sensor Detects water...reliably! Strong penetration power Not affected by drops, bubbles or froth Conforming to EMC Directive UL Recognition (Excluding m cable length type)

More information

EX-F70 SERIES EX-F60 SERIES

EX-F70 SERIES EX-F60 SERIES 85 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES General terms and conditions... F-17 General precautions... P.105 Sensor selection guide... P.81~ Korea s S-mark... P.110 PHOTO

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global 3 Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.549~ guide... P.3~ General precautions... P.55~ PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in) 817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global

More information

High-speed detection even a little liquid leak

High-speed detection even a little liquid leak 737 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES Sensor selection guide...p.11~ / P.77~ General terms and conditions...p.1 General precautions...p.986~ PHOTO PHOTO Conforming

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space. DC 2-wire Cylindrical Inductive Proximity SERIES High performance & ease of use Amplifier Built-in Robust in tightening The tightening torque has been improved to approx. four times greater than that of

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less. INUCTIVE SERIES Compact Inductive Proximity Sensor Flexible cable Metal embedding type available possible Amplifier Built-in High functionality together with robust housing and flexible cable GA-/GH -N

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety

GXL SERIES. High performance in micro-size design. Micro-size Inductive Proximity Sensor PROXIMITY SENSORS INDUCTIVE. Wide model variety SERIES Micro-size Inductive Proximity -wire available PNP output Oil resistant Flexible cable Different freq. available available available Amplifier Built-in High performance in micro-size design GA-/GH

More information

Cylindrical Inductive Proximity Sensor GX-M SERIES

Cylindrical Inductive Proximity Sensor GX-M SERIES Cylindrical Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Features Wide product range Types: DC 3-wire shielded type DC 3-wire non-shielded type DC 2-wire standard type DC

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator GA- SERIES Amplifier-separated Micro-size Inductive Proximity Sensor GH SERIES -N -U Slim & Small The amplifier is extremely slim, just mm thick. This results in a compact size even if several amplifiers

More information

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Installation The VDS-1000 combines either two (2) low voltage, high side or low side, switched outputs

More information

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES. Cylindrical Sensors Photoelectric Sensor CY-100 SERIES Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Cylindrical Inductive Proximity Sensor GX-M SERIES Cylindrical Photoelectric

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

Rectangular-shaped Inductive Proximity Sensor.

Rectangular-shaped Inductive Proximity Sensor. 69 PHOTO PHOTO Rectangular-shaped Inductive Proximity Sensor -F/H SERIES Related Information Amplifi er General terms and conditions... P.1 Sensor selection guide...p.11~ / P.67~ Glossary of terms... P.19

More information

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications INUCTIVE SERIES Compact Inductive Proximity -N -U G-8H/8H G-N G-8U G-6 Miniature -S is an amplifier built-in inductive proximity sensor having a diameter of just ".8mm. -S ".8mm Various Applications The

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor

More information

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small.

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small. G- SERIES Miniature Inductive Proximity Sensor High Performance in Surprisingly Small Body Marked Conforming to EMC Directive Extremely Small Mountable in a tight space as the sensor is just 19mm in volume.

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure High Precision, Series SE30/ISE30 How Order Option 1 Without lead wire Lead wire with connecr (Lead wire length: 2 m) L For positive pressure For vacuum/low pressure ISE30 01 SE30 01 25 M 25 M 01 R 1/8

More information

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model

GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. GX-12ML(B) Conventional model SERIES DC -wire Cylindrical Inductive Proximity High Performance & Ease of Use Marked Conforming to EMC Directive Robust in Tightening The tightening torque has been improved to approx. four times greater

More information

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Compact Size: 5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. INDUCTIVE SERIES DC -wire Cylindrical Inductive Proximity G-8H/8H G-N G-8U G-6 Robust in Tightening The tightening torque has been improved to approx. four times greater than that of conventional models

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth! Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch

More information

High-frequency AC Method. panasonic-electric-works.net/sunx

High-frequency AC Method. panasonic-electric-works.net/sunx 1091 PHOTO PHOTO Thin Type Ionizer High-frequency AC Method General terms and conditions... F-17 Related Information Glossary of terms... P.1401 guide... P.1075~ General precautions... P.1405 Conforming

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

19mm Thickness. Phone: Fax: Web:

19mm Thickness. Phone: Fax: Web: 19mm Thickness Minimum Space Required Type2 Appropriate Safety Safety level required by global standards 'Safety' has joined 'Environment' as one of the keywords of the new century. The importance of machine

More information

EX-F70 SERIES EX-F60 SERIES

EX-F70 SERIES EX-F60 SERIES 877 Leak Sensor Amplifier Builtin EXF70 SERIES SERIES Related Information General terms and conditions... F General precautions... P.155~ guide... P.865~ Korea s Smark... P.160 PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global

More information

Compact Size: "5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Compact Size: 5.4mm. GX-5SU(B) is just 5.4mm in diameter, the smallest in existing DC two-wire sensors. It saves you space. SERIES DC -wire Cylindrical Inductive Proximity High Performance & Ease of Use Marked Conforming to EMC Directive Robust in Tightening The tightening torque has been improved to approx. four times greater

More information

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids Leakage rating: 1 X 10-9 atm cc/s With Backlight Digital Pressure Switch Series ZSE6B (For vacuum) ISE6B (For positive pressure) Sensor and fitting section are electron beam welded. 2 kinds of metal gasket

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Versatile Mounting. Wide Model Variety

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Versatile Mounting. Wide Model Variety GX SERIES AUDIN Composants & systèmes d'automatisme avenue de la malle - 17 St Brice Courcelles - France Tel. +()61 Fax +()6 http://www.audin.fr e-mail info@audin.fr Micro-size Inductive Proximity High

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting

Series PSE100. Controller PSE10. How to Order. Controller Specifications Option. Output specifications. Mounting Controller Series PSE100 How to Order PSE10 Output specifications 0 NPN output 1 PNP output Mounting A B Option Without cover C With cover Panel mounting Wall mounting, DIN rail Controller Specifications

More information

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1)

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1) Pressure Gauge Feature The compact-size pressure gauges can be installed in small spaces. With the built-in tube fitting type, tube connection is the only necessary step before pressure indication. Graphical

More information

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance 11 High Accuracy ddy Current Type Sensor SRIS Related Information General terms and conditions... F-7 Glossary of terms... P.1493 Sensor selection guide... P.1055~ General precautions... P.1501 PHOTO PHOTO

More information

2-Color Display Digital Flow Switch

2-Color Display Digital Flow Switch -Color Display Digital Flow Switch Series Flow rate range:, 5, 5, l/min. Minimum unit setting:. l/min. (. l/min when the flow rate range is 5, 5, l/min.) Repeatability: ±%F.S. or less Grease-free Flow

More information

Digital Pressure Sensor

Digital Pressure Sensor Digital Pressure Sensor SALIENT FEATURES IP 65 enclosure Hysteresis Adjustable Programmable Pressure unit Dual Digital & Voltage Outputs Wide measurement range 1~10 bar Model Number Legend 1 2 3 4 1. Series

More information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information Flat Inductive Standard Flat s in Many Different Variations Only 6 mm thick yet provides a sensing distance of mm (MC1). Aluminum die-cast models also available. Be sure to read Safety Precautions on page

More information

CX-20. General Purpose Photoelectric Sensor with Full Basic Performance. SERIES Amplifier Built-in Compact Photoelectric Sensor PHOTOELECTRIC SENSORS

CX-20. General Purpose Photoelectric Sensor with Full Basic Performance. SERIES Amplifier Built-in Compact Photoelectric Sensor PHOTOELECTRIC SENSORS SERIES Amplifier Built-in Compact Photoelectric FX-D/A/M FX-A FX- Fiber s General Purpose Photoelectric with Full Basic Performance FZ- Compact Size Two s Mountable Together Waterproof Just mm in depth,

More information

Low Differential Pressure Sensor ±1% F.S.

Low Differential Pressure Sensor ±1% F.S. CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kpa Accuracy: ±1% F.S. LED display to confirm energization Series PSE550 Proof pressure: 65kPa Output: 1 to 5VDC

More information

PX-2 SERIES. onlinecomponents.com. Compact size sensor realizes wide sensing area & long sensing range. Long Range & Wide Area Photoelectric Sensor

PX-2 SERIES. onlinecomponents.com. Compact size sensor realizes wide sensing area & long sensing range. Long Range & Wide Area Photoelectric Sensor EQ- VF NX PM PM MS-J RT- CY POTOEECTRIC SENSORS SERIES ong Range & Wide rea Photoelectric Sensor Ideal area with very little null zone The advanced optical system of the series reduces the null zones in

More information

Indicators reveal the sort of an abnormal condition. Emitter Emitting Controller Power indicator

Indicators reveal the sort of an abnormal condition. Emitter Emitting Controller Power indicator AREA SENSOR SERIES mm Beam Pitch NA1-5 NA2 SF1-F NA40 SF1-N SF1-A Slim Body Fail-safe esign For General Use Supreme Fail-safe esign The system always check there is no internal circuit, no cable breakage,

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Wide Model Variety. Versatile Mounting

GXL SERIES. Micro-size Inductive Proximity Sensor. High Performance in Micro-size Design. Marked. Wide Model Variety. Versatile Mounting GX SERIES Micro-size Inductive Proximity High Performance in Micro-size Design Marked Conforming to EMC Directive Wide Model Variety Models ranging from extremely compact to long range are available to

More information

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION marking Compatible with EMC directive INTERNAL STRUCTURE 5 1 2 6 4 3 Part name Material FEATURES 1 Pressure sensor P-2000 Compact and lightweight general-purpose pressure gauges Innovative general-purpose

More information

2-Colour Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L For positive pressure For vacuum/low

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics The ZSE3/E3 series is to be discontinued. We recommend you consider using the Z/E10 series or the

More information

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa Series 0-PSE50 Remote type pressure sensor How to Order Clean series 0 PSE5 0 M5 Pressure sensing range Option 0 2 High pressure [0 to MPa] Vacuum [0 to 0 kpa] Low pressure [0 to 0 kpa] Compound pressure

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT Compact Manometer Pressure measurements can easily be taken any time, anywhere. RoHS Compact and lightweight Portable type with a lightweight of only about 00 g (unit 50 g, battery 50 g) can also be held

More information

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS

SECTION 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS SYSTEM ACCESSORIES SECTI 6 VACUSTAT, PRESSURE SENSORS, VACUUM SENSORS, & FILTERS 6 2012 EDCO USA. www.edcousa.net 6:1 6 SYSTEM ACCESSORIES CTENTS VACUSTAT MECHANICAL PRESSURE SWITCH INLINE VACUUM FILTER

More information

Remote Type Pressure Sensors Pressure Sensor Controllers

Remote Type Pressure Sensors Pressure Sensor Controllers CT.EUS1-56B-UK Remote Type Pressure Sensors Pressure Sensor Controllers Compact Pressure Sensor for Pneumatics PSE53 Multi-channel Digital Pressure Sensor Controller PSE2 Compact Pressure Sensor for Pneumatics

More information

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance R High-Precision Fiber-optic Amplifier TheEmploysa16-Bit Processor as An Industry First H An Automatic Sensitivity Adjustment feature allows stable detection of objects in frequently changing environments

More information

Possible to create the highest level safety system

Possible to create the highest level safety system 14 LIGHT CURTAIS (For PP output type light curtain) Control category 4 Possible to create the highest level safety system Conforming to achine Directive & C Directive Approved Listing Compatible up to

More information

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features. Data sheet 405052 Page 1/10 JUMO DELOS SI Precision pressure transmitter with switching contacts and display Application Food & pharma CIP/SIP systems Machine and system construction Air conditioning and

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS MULTISTAGE MICRO EJECTORS MED07-E, MED10-E Specifications Basic model Item Media Operating pressure range MPa [psi.] Proof pressure MPa [psi.] Operating temperature range (atmosphere and media) C [ F]

More information

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,

More information

Vacuum pumps/generators Small

Vacuum pumps/generators Small picompact10 Ejector with COAX patented technology. Reduced air-consumption with 30-50% compared to other ejector technologies. Easy to optimize vacuum performance with a varied selection of micro multi-stage

More information

JUMO MIDAS S05 Pressure transmitter Type

JUMO MIDAS S05 Pressure transmitter Type Data Sheet 40.00 Page /8 JUMO MIDAS S05 Pressure transmitter Type 4000 Brief description The JUMO MIDAS S05 pressure transmitter is available with both relative pressure and absolute pressure measurement

More information

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050 Data sheet Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050 The compact heavy duty pressure transmitters MBS 2000 and MBS 2050 are designed for use in hydraulic applications. MBS

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 Description: The EDS 3000 is a compact, electronic pressure switch with integral digital display. The unit can have one or two switching outputs, and there is the option of an additional analogue output

More information

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10 Electronic Pressure Measurement WIKA Datasheet PSD-10 Applications Hydraulics and pneumatics Filter monitoring Pump control

More information

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 Data sheet Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all industrial applications, and offers

More information

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa

ISE7 /7 G Series CAT.ES B. MPa/1.6 MPa 1.0. MPa/2.0 MPa. MPa/10 MPa 3-Screen Display High-Precision Digital Pressure Switch Air General Fluids 1.0 ISE70 ISE71 MPa/1.6 MPa 1.0 ISE70G ISE75G MPa/2.0 MPa 5.0 ISE76G ISE77G MPa/10 MPa It is possible to change the settings while

More information

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle

More information

Vacuum Equipment. Application. Series

Vacuum Equipment. Application. Series Equipment Series Application Page ejector In-line vacuum ejector Multistage ejector ejector with check valve Pad with check valve ejector for water soluble coolant removal ZH ZU ZL1/2 (Special order product)

More information

Electronic pressure switch for air

Electronic pressure switch for air pressure switch Sensors / pressure sensor Overview pressure is electrically detected, displayed and outputted. Features Various sort Wide variation is acailable from small sensor to display. CONTENTS Series

More information

E2EZ-X2D1-N E2EZ-X2D2-N

E2EZ-X2D1-N E2EZ-X2D2-N Chip-immune Inductive s Detects Objects without Being Influenced by Aluminum or Iron Chips Series now includes M s. s also available. CE Marking for DC -Wire and DC -Wire s. Be sure to read Safety Precautions

More information

Series PSE560 Pressure Sensor For General Fluids... 90

Series PSE560 Pressure Sensor For General Fluids... 90 Table of Contents Pressure Switch Selection Guide... Electronic Pressure Switch... Mechanical Pressure... Pressure Switch Application Example... Series SE/ISE High Precision, 2-color Display Digital Pressure

More information

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050 The compact pressure transmitter, type MBS 3000, is designed for use in almost all

More information

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1 Compact Flow Rate Sensor RAPIFLOW Resin Body Type Diversified High Performance High performance User-friendly Compatible CC-1235A 1 Diversified Five types of gases can be measured with just one unit Gas

More information

ER-VSERIES. A new style of charge removal. New ultra-compact, high-performance ionizer! ULTRA-COMPACT IONIZER High-frequency AC Method

ER-VSERIES. A new style of charge removal. New ultra-compact, high-performance ionizer! ULTRA-COMPACT IONIZER High-frequency AC Method STATIC REMOVER UTRA-COMPACT IONIZER High-frequency AC Method ER-VSERIES Conforming to EMC Directive A new style of charge removal New ultra-compact, high-performance ionizer! Phone:.9.1 - Fax:.73.773 -

More information