Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12

Size: px
Start display at page:

Download "Signaling solutions. Monolithic indicator banks Harmony type XVC. Dimensions: page 12"

Transcription

1 Presentation Presentation The monolithic indicator banks in the Harmony XVC range are designed for long distance indication of the operating states or sequences of a machine or installation, either visually by means of illuminated signaling units visible through 60, or audibly by means of a buzzer adjustable up to 8 db. b The range includes small diameter products (0 and 60 mm) and larger diameter products (00 mm). It is therefore suitable for use in virtually all activity sectors : v XVC B (0 mm) indicator banks are used mainly in the food-processing and medical sectors, v XVC 6B (60 mm) indicator banks are used in semi-conductor factories, on conveyor belts and on small food or drink dispensing machines in the commercial sector, v XVC B (00 mm) indicator banks are more particularly designed for industrial applications and machine-tools. b The entire range provides an IP degree of protection to allow outdoor as well as indoor use. b XVC indicator banks are supplied: v with,,,, or illuminated signaling units, v with or without a buzzer, v pre-assembled and pre-wired, v tted with a support tube and bracket for mounting on a vertical support or screws for direct mounting on a horizontal surface (depending on the model). Illuminated signaling lens unit colours are available from the catalogue: red, orange, green, blue or clear. The colours are always placed in that order, from top to bottom. The light source consists of super bright LEDs which provide optimum luminosity. Audible signaling The indicator bank is supplied with or without an audible signaling unit (buzzer) depending on the required con guration. The buzzer is located in the base of the indicator bank. The type of signal (continuous or intermittent) can be reversed by modifying the cable connections (only for 60 and 00 mm products). A potentiometer is also present in the base for adjusting the audible signaling volume, up to a value of 8 decibels. Cabling XVC indicator banks supplied pre-assembled are equipped with wires marked with a label indicating the correct way to connect. Each level is marked by a different coloured wire. XVC indicator banks that have been pre-assembled and pre-wired at the factory cannot be modi ed because the wires are permanently connected (soldered). page 0 page page Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

2 Description A Description XVC indicator banks comprise an assembly of: A cover. One, two, three, four or ve coloured illuminated signaling units (red, orange, green blue or clear). Each illuminated unit is equipped with an LED ( superbright LED ). A base mounted on the support tube A or a base tted with screws B for direct mounting on a horizontal surface (both of these base types can incorporate a buzzer). An aluminium support tube mounted on a bracket, for mounting on a vertical support (depending on the model). Marked wires, with projecting length of 00 to 900 mm (depending on the model). B Caracteristics: page 0 page page Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

3 Characteristics Indicator banks Ø 0 and Ø 60 mm Environment characteristics Product certifications UR (), e Conformity to standards For XVC B EN , EN For XVC 6B EN , EN , EN Protective treatment TC Ambient air temperature Storage C Operation C Electric shock protection conforming to IEC 60 Mounted on support tube Mounted on base Class I Class II Degree of protection conforming to IEC 609 Mounted on support tube Mounted on base IP (Flat surface installation) IP (Vertical surface installation) IP (Flat surface installation) Material Top cover PBT + ABS (UL9HB) Illuminated lens unit Polycarbonate Body part ABS Support tube STK (chromium-plated) L mounting bracket SPC (unichromium-plated) Light source LED Electrical characteristics Voltage limits V z V ± 0 % Rated impulse withstand voltage Consumption (at maximum voltage) kv 0.8 Steady light V unit ma 0 units ma 80 units ma 0 units ma 60 units ma 00 Steady/ ashing light V with buzzer unit ma 90 units ma 0 units ma 70 units ma 0 units ma 0 Audible units Sound level (continous or db intermittant tone) at m Fundamental frequency khz.0 Flashing frequency of Hz illuminated units Connection Wire c.s.a.: 0. mm / AWG () Available in June 008. page 0 page page 6 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

4 Characteristics Indicator banks Ø 00 mm Environment characteristics Product certifications UR, e Conformity to standards EN , EN , EN Protective treatment TC Ambient air temperature Storage C Operation C Electric shock protection conforming to IEC 60 Mounted on support tube Mounted on base Class I Class II Degree of protection Mounted on support tube IP conforming to IEC 609 Material Top cover PBT + ABS (UL9HB) Lens unit Polycarbonate Body part ABS LIght source LED Electrical characteristics Voltage limits V c V ± 0 % Rated impulse withstand voltage Consumption (at maximum voltage) kv 0.8 Steady light V unit ma 00 units ma 00 units ma 00 units ma 00 units ma 00 Steady/ ashing light V with buzzer unit ma 0 units ma 0 units ma 0 units ma 0 units ma 0 Audible units Sound level (continous or db intermittant tone) at m Fundamental frequency khz Flashing frequency of Hz 0.. illuminated units Connection Wire c.s.a.: 0. mm / AWG page 0 page page Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

5 References Indicator banks Ø 0 and Ø 60 mm Complete, pre-wired indicator banks Ø 0 mm A A Description Light source (included) For support tube mounting, 7 mm Without buzzer LED for steady light only Voltage Signaling colours () Reference Weight kg V Steady Flashing () z R XVC B 0.00 R, O XVC B 0.0 R, O, G XVC B 0.0 R, O, G, B XVC B 0.60 R, O, G, B, C XVC B 0.80 With buzzer + flashing light LED for steady or ashing light z R R XVC BS R, O R, O XVC BS 0.60 R, O, G R, O, G XVC BS 0.60 R, O, G, B R, O, G, B XVC BS R, O, G, B, C R, O, G, B, C XVC BS For base mounting Without buzzer LED for steady light only z R XVC BK 0.00 R, O XVC BK 0.0 R, O, G XVC BK 0.0 R, O, G, B XVC BK 0.60 R, O, G, B, C XVC BK 0.80 Accessories for support tube mounting Description Diameter Minimun height to be added Reference Weight mm mm kg XVC B XVC BS Metal fixing plate 90 XVC Z Plastic fixing plate 8. XVC Z Complete, pre-wired indicator banks Ø 60 mm Description Light source (included) Voltage Signaling colours () Reference Weight kg V Steady Flashing () For support tube mounting, mm Without buzzer LED for steady light only z R XVC 6B R, O XVC 6B 0.70 XVC Z R, O, G XVC 6B R, O, G, B XVC 6B 0.80 R, O, G, B, C XVC 6B A06 With buzzer + flashing light LED for steady or ashing light z R R XVC 6BS R, O R, O XVC 6BS 0.90 R, O, G R, O, G XVC 6BS R, O, G, B R, O, G, B XVC 6BS.00 R, O, G, B, C R, O, G, B, C XVC 6BS.060 A0608 For base mounting Without buzzer LED for steady light only z R XVC 6BK 0.00 R, O XVC 6BK 0.0 R, O, G XVC 6BK 0.00 R, O, G, B XVC 6BK 0.0 R, O, G, B, C XVC 6BK 0.00 With buzzer + flashing light LED for steady or ashing light z R R XVC 6BSK 0.00 R, O R, O XVC 6BSK 0.0 R, O, G R, O, G XVC 6BSK 0.00 R, O, G, B R, O, G, B XVC 6BSK 0.0 R, O, G, B, C R, O, G, B, C XVC 6BSK 0.00 XVC 6BK XVC 6BSK Accessories for support tube mounting Description Diameter Minimun height to be added Reference Weight mm mm kg Metal fixing plate for XVC 6Bp and XVC 6BpS 00 0 XVC Z Metal fixing plate for XVC 6Bp K and XVC 6BpSK 8.6 XVC Z 0.00 () Signaling colours: R: Red, G: Green, O: Orange, B: Blue, C: Clear. The colours are listed in the same order as the mounting order of the illuminated units (from top to bottom). () Flashing function can be simply selected/programmed by wiring. page page 8 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

6 References Indicator banks Ø 00 mm A068 Complete, pre-wired indicator banks Ø 00 mm Description For base mounting Without buzzer With flashing light Light source (included) LED for steady or ashing light Voltage Signaling colours () Reference Weight kg V Steady Flashing () c R R XVC BK R, O R, O XVC BK R, O, G R, O, G XVC BK.00 R, O, G, B R, O, G, B XVC BK.00 R, O, G, B, C R, O, G, B, C XVC BK.00 With buzzer + flashing light LED for steady or ashing light c R R XVC BSK R, O R, O XVC BSK XVC BK/XVC BSK R, O, G R, O, G XVC BSK.00 R, O, G, B R, O, G, B XVC BSK.00 R, O, G, B, C R, O, G, B, C XVC BSK.00 A06606 Accessories for mounting on vertical support Description Diameter Height Reference Weight mm mm kg Aluminium expansion tube with metal fixing plate 0 00 XVC Z Metal fixing bracket XVC Z 0.80 XVC Z () Signaling colours: R: Red, G: Green, O: Orange, B: Blue, C: Clear. The colours are listed in the same order as the mounting order of the illuminated units (from top to bottom). () Flashing function can be simply selected/programmed by DIP switches in each luminous unit. It is also possible to regulate the fl ashing frequency. page page Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

7 Dimensions Indicator banks Ø 0 mm Pre-assembled and pre-wired indicator banks With support tube mounting For direct mounting on horizontal support XVC Bp XVC BpS XVC BpK Ø0 0 xm Ø , b 8 6, b Ø7, Ø Ø0 Ø 0 Ø0, 0 b Panel cut-out xø Ø0 7 Ø xø9 0 Height of pre-assembled and pre-wired indicator banks No. of illuminated units b Without buzzer (mm) b With buzzer (mm) No. of illuminated units b (mm) Without buzzer stage 0.. stage 00. stages stages. stages stages 70. stages stages 00. stages. 66. stages 0. Accessories for indicator banks type XVC Bp and XVC BpS Metal fixing plate, XVC Z Plastic fixing plate, XVC Z0 Ø 6,??? Ø90 Ø () Ø7 () () elongated holes Ø. x. () elongated holes Ø. x. page 0 page 0 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

8 Dimensions (continued) Indicator banks Ø 60 mm Pre-assembled and pre-wired indicator banks With support tube mounting For mounting on horizontal support (direct or with fixing plate) XVC 6Bp XVC 6BpS XVC 6BpK, XVC 6BpSK xm Ø60 Ø Ø0 Ø6,8 Ø60,8 9 6, b,8 9 6, b Ø 0 Ø60 Panel cut-out,, ,8 b Ø0 0 Ø 0 8 xø xø 0 Height of pre-assembled and pre-wired indicator banks No. of illuminated units b Without buzzer (mm) b With buzzer (mm) No. of illuminated units b (mm) With or without buzzer Accessories for mounting on vertical support Metal fixing plate XVC Z0 for indicator banks XVC 6Bp and XVC 6BpS Ø0 () elongated holes Ø. x 7. Metal fixing plate XVC Z for indicator banks XVC 6BpK and XVC 6BpSK Ø8 6 Ø00 6 Ø8 0,6 () Ø7 Ø0 Ø xø xø, page 0 page Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

9 Dimensions (continued) Indicator banks Ø 00 mm Pre-assembled and pre-wired indicator banks For mounting on horizontal support (direct or with fixing plate) XVC BpK, XVC BpSK indicator banks XVC Z fixing plate Ø xø Ø 0 80 Ø00 xm Ø 0 xø b 0 XVC Z fixing plate Ø0 Ø,7 00 xø7 88 Ø 0 x M Ø Panel cut-out 9 xø6 Ø 0 xø6 xø0, 0 Height of pre-assembled and pre-wired indicator banks No. of illuminated units b (mm) page 0 page Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

10 Schemes Ø 0 mm XVC Bp, XVC BpK WH BU GR YE OR NPN PNP XVC BpS B WH BU GR YE OR Buzzer BN Flashing GY NPN PNP Indicator bank with or without buzzer : th illuminated unit (red LED, orange wire) : th illuminated unit (orange LED, yellow wire) : rd illuminated unit (green LED, green wire) : nd illuminated unit (blue LED, blue wire) : st illuminated unit (clear LED, white wire) B: Buzzer sound (brown wire) Flashing COM (grey wire) + RD F z V BK RD F + z V Ø 60 mm XVC 6Bp, XVC 6BpK WH BU GR YE OR NPN PNP XVC 6BpS, XVC 6BpSK B WH BU GR YE OR Buzzer BN Buzzer VT Flashing GY NPN PNP Indicator bank with or without buzzer : th illuminated unit (red LED, orange wire) : th illuminated unit (orange LED, yellow wire) : rd illuminated unit (green LED, green wire) : nd illuminated unit (blue LED, blue wire) : st illuminated unit (clear LED, white wire) B: Buzzer sound v Intermittent sound (brown wire) v Continuous sound (violet wire) Flashing COM (grey wire) + RD F z V BK RD F + z V Ø 00 mm XVC BpK WH BU GR YE RD OR BN NPN PNP XVC BpSK WH BU GR YE RD Buzzer OR Buzzer BN NPN PNP Indicator bank with or without buzzer : th illuminated unit (red LED, red wire) : th illuminated unit (orange LED, yellow wire) : rd illuminated unit (green LED, green wire) : nd illuminated unit (blue LED, blue wire) : st illuminated unit (clear LED, white wire) B: Buzzer sound v Intermittent sound (brown wire) v Continuous sound (orange wire) Flashing COM (grey wire) COM GY B COM GY WH + BK F c V WH + BK F c V page 0 page Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA Main Office: (60) Outside Local Area: (800)

Page 8-3. MULTICOLOURED SIGNAL TOWERS Ø70mm/2.75. Modular signal towers Ø70mm/2.75

Page 8-3. MULTICOLOURED SIGNAL TOWERS Ø70mm/2.75. Modular signal towers Ø70mm/2.75 Page -2 SIGNAL TOWERS Ø45mm/1.77 Signal towers supplied already assembled Ø45mm/1.77 Steady light modules Pulsed or continuous sound modules Built-in LED circuit. Page -3 MULTICOLOURED SIGNAL TOWERS Ø70mm/2.75

More information

Signal towers and beacons

Signal towers and beacons Signal towers 5mm/1.77 Supplied already assembled Steady light and pulsed or continuous sound modules Multicoloured signal towers Ø70mm/2.75 Modular and combinations up to 5 modules Steady light and pulsed

More information

Switches Unlimited Contact: Phone: * Fax:

Switches Unlimited Contact: Phone: * Fax: Phone: 00-221-047 * Fax: 71-672-6370 Page -2 Page -3 SIGNAL TOWERS Signal towers Ø70mm Steady, blinking light or flash modules Pulsed or continuous sound modules Incandescent and LED bulbs. SIGNAL BEACONS

More information

Battery Voltage, Overload Protected Hot only in Start & Run 15 GN (green)

Battery Voltage, Overload Protected Hot only in Start & Run 15 GN (green) Wiring Diagrams Design of Wiring System Determine and Define of Wires Circuit Numbers and Wire Identification will be done according the World-wide Engineering Drafting Standard WH-110-01. The circuit

More information

PRODUCT SPECIFICATION. Stack Lights. Series.

PRODUCT SPECIFICATION. Stack Lights. Series. PRODUCT SPECIFICATION Stack Lights Series www.wernerelektrik.com Light Color Significance... Specifications... Functional Specification... Model Number Structure - Stack Lights... Model Number Selection...

More information

ASI. Blinking or Steady Light Modules

ASI. Blinking or Steady Light Modules Signal beacons Ø6mm / Ø.44 Steady light modules. BA5d fitting. Bulb not included. LB6 EL Orange 0.060 LB6 EL3 Green 0.060 LB6 EL4 Red 0.060 LB6 EL5 Yellow 0.060 LB6 EL6 Blu 0.060 LB6 EL White 0.060 Blinking

More information

Signal Tower K 70 Signal Beacons K SB. New in the ABB Pilot devices assortment

Signal Tower K 70 Signal Beacons K SB. New in the ABB Pilot devices assortment Signal Tower K 70 Signal Beacons K SB New in the ABB Pilot devices assortment New in the ABB Pilot devices assortment Signal Tower K 70 - Fast mounting of signal elements using bayonet fixing - Easy changing

More information

SIGNAL BEACONS Signal beacons Ø62mm Blinking or steady light modules Sound-light pulsed or continuous modules Incandescent and LED bulbs.

SIGNAL BEACONS Signal beacons Ø62mm Blinking or steady light modules Sound-light pulsed or continuous modules Incandescent and LED bulbs. Page -2 Page -3 SIGNAL TOWERS Signal towers Ø70mm Steady, blinking light or flash modules Pulsed or continuous sound modules Incandescent and LED bulbs. SIGNAL BEACONS Signal beacons Ø62mm Blinking or

More information

onlinecomponents.com

onlinecomponents.com s M5 x 0,5 / Accessories s M5 x 0,5 / 15,5 7,5 8,1 8,5 6 M5 x 0,5 5,5 3 ESW 05SP00 3 pin 2 m PUR ESW 05SP0500 3 pin 5 m PUR ESW 05S ESW 08S / ES 8A 6 M5 x 0,5 8 25,4 29,5 ESW 08SH00 3 pin 2 m PUR ESW 08SH0500

More information

The modular structure makes it possible to build at least 5 configurations for each visual lens unit

The modular structure makes it possible to build at least 5 configurations for each visual lens unit 180 SERIES Modular visual and audible indicators A simple bayonet system simplifies the mounting and maintenance, which can be performed in complete safety The wiring unit can be easily reached and extracted,

More information

2/3 Port Mechanical Valve. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)

2/3 Port Mechanical Valve. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic) 2/3 Port Mechanical Valve Series 00 Large flow capacity. A variety of actuator types. Specifications Fluid Operating pressure Ambient and fluid temperature Effective area Lubrication Port size Mass (Basic)

More information

Switches- and Indicators

Switches- and Indicators Switches- and Indicators Contents Description... 3 Product Assembly... 4 Mounting instruction... 6 Devices raised mounting... 7 Devices flush mounting... 17 Accessories... 22 Technical Data... 25 Typical

More information

Eco-Modul 60 Signal tower

Eco-Modul 60 Signal tower 37 60 Signal tower Ø 60 mm modular signal tower series Complete range of high-luminosity LED light modules with steady/flashing/strobe beacon functions, 6 different lens colours High-performance steady

More information

Multi-function. Mono-function 1 NO (SPST-NO)

Multi-function. Mono-function 1 NO (SPST-NO) Features Range of electronic staircase timers 17.5 mm wide Time setting from 30 s to 20 min Zero crossing load switching Switch-off early warning - model 14.01 Suitable for 3 or 4 wire systems, with automatic

More information

Brushless DC Axial Fans

Brushless DC Axial Fans Brushless DC Axial Fans General Specifications Material: Body PBT UL 9V- Fan PBT UL 9V- Insulation Class E Approvals UL, cul Recognized E89 Box Count: x 8 pieces x pieces 9 x pieces 8 x pieces x pieces

More information

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures

Number of PG holes. 1 x PG 9 (Ø 15.5) 12 x PG 13.5 (Ø 21) 1 x PG 9 (Ø 15.5) /300/400/ Rittal Catalogue 32/Industrial Enclosures us enclosures G. us enclosures Enclosure:.38 Door:.5 IP 65 to EN 60 59/09.00, complies with NEMA. Door with l/h hinge, cam lock with double-bit insert, () support rail(s) S 35/7.5 (for G 586.). Drilled

More information

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition Pre-assembled and pre-cabled in different aperture to highlight the processes LED Signal Towers Modular and monolithic design are available. Patlite s extensive product range cover highly advanced LED

More information

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT

OsiSense. XC Basic Limit Switches XCMN, XCKN, XCNT OsiSense XC Basic Limit Switches XCMN, XCKN, XCNT Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com - www.stevenengineering.com Courtesy of Steven Engineering, Inc. - () - - sales@steveneng.com

More information

Q SERIES Ø16mm (.630") Panel Mount LED Indicators Distinctive features and specification

Q SERIES Ø16mm (.630) Panel Mount LED Indicators Distinctive features and specification Distinctive features and specification VOYC1603R1US Features 16mm panel mounting LED indicator 10mm colored diffused epoxy lens or 10mm water clear super bright LEDs Plated brass bezel finished in bright

More information

7. 4 th Stack Lens Color

7. 4 th Stack Lens Color Industrial Tower Lamps Ø56mm; Bulb Type with Buzzer TBK Model Number Legend 1 2 1. Series TBK 2. Type www.inno.sg/tbk 3 4 5 6 7 8 9 B: Direct Mount (no pole) P: Direct Mount S: Panel Mount 3. Indication

More information

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility

Signaling Lights LD6A. LD6A LED SignaLight Towers Assembled Products. Unique Striped Design Improves Visibility Unique Striped Design Improves Visibility Key features of the LD6A LED SignaLight Towers include: The striped design with non-illuminated area between the lenses makes the illuminated color very visible.

More information

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel Raised design Emergency-stop switch, foolproof EN IEC 60947-5-5, IP 65 Equipment consisting of (schematic overview) L1 35.6 6 max. 59.5 41 18x24 Actuator Product can differ from the current configuration.

More information

Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily.

Series. Able to control the stroke with only ON/OFF signals. Directional control driver like a solenoid valve. Able to set thrust arbitrarily. P099-P0998-E.qxd 0..5 :5 AM Page 99 Directional Control Driver for Electric Cylinder Series LCF LJ LG LCF-5A 첸 LCF-5A5 첸 LTF Able to control the stroke with only / signals. LC Directional control driver

More information

Q16 series. Ø16 mm panel mount LED indicators DISTINCTIVE FEATURES ENVIRONMENTAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS MOUNTING

Q16 series. Ø16 mm panel mount LED indicators DISTINCTIVE FEATURES ENVIRONMENTAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS MOUNTING IND-Q16-17-07 LED INDICATORS DISTINCTIVE FEATURES Secret until lit polycarbonate decals or custom engraving 10 mm colored diffused epoxy lens or 10 mm water clear super bright LEDs (2.8 x 0.8) solder lug/faston

More information

Q19 series. Ø19 mm panel mount LED indicators DISTINCTIVE FEATURES ENVIRONMENTAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS MOUNTING

Q19 series. Ø19 mm panel mount LED indicators DISTINCTIVE FEATURES ENVIRONMENTAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS MOUNTING IND-Q19-17-07 LED INDICATORS DISTINCTIVE FEATURES 10 mm colored diffused epoxy lens or 10 mm water clear super bright LEDs Prominent and flush bezel styles (2.8 x 0.8) solder lug/faston terminals, pins

More information

Thermal-Magnetic Circuit Breaker 201/-WA

Thermal-Magnetic Circuit Breaker 201/-WA Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring

More information

General_technical_data Series

General_technical_data Series Emergency-stop Switching system The double-break switching system can be supplied for the following switching functions: 1 Normally closed, 2 Normally closed, 1 Normally closed + 1 Normally open. The Normally

More information

General_technical_data Series

General_technical_data Series Indicator Lens Actuator Cable 2-poles with plug-in connection 2.8 x 0.8 mm Flat plug-in housing rectangular, AMP No. 626 057-0 Receptacle housing AMP No. 626 0-0 Receptacle socket AMP No. 160 655-2 Wire

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x x 46 mm) Four contacts Gold-plated contacts

More information

Energy Monitoring (Plug-in to II *1 )

Energy Monitoring (Plug-in to II *1 ) What is the Energy Monitoring? A plug-in (Add-on) of Interactive Intelligence which calculates the Energy Consumption of a complete system What are the features of the package? Automatic Configuration

More information

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No Series 03. mm x 4. mm IP40/IP65 0 A 400 VAC Choose one component from each of the coloured sections to assemble a complete switch. For other options or further information please contact your local sales

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Ultrasonic sensors OsiSense XX Cylindrical plastic case, M12 x 1, M18 x 1, M30 x 1.5 DC supply, solid-state output

Ultrasonic sensors OsiSense XX Cylindrical plastic case, M12 x 1, M18 x 1, M30 x 1.5 DC supply, solid-state output References Cylindrical plastic case, M x, M x, M x. XX AKAM XX AppL XX AKAM XX AKAM XX ApAM XX ApCM Fixed distance sensors Sensors Sensing Function Connection Output Reference Weight distance (Sn) m Ø.

More information

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)

Flow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42) Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable

More information

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Magnetic switch For bypass level indicators Model BGU for nuclear power plants Level measurement Magnetic switch For bypass level indicators BGU for nuclear power plants KSR data sheet BGU for NPP Applications Magnetic switches for detecting the limits of filling levels in bypass

More information

AKM 105, 115: Rotary actuator for ball valve

AKM 105, 115: Rotary actuator for ball valve Product data sheet 51.363 AKM 105, 115: Rotary actuator for ball valve Improving energy efficiency Torque-dependent cut-off facility for efficient usage of energy Features For actuating 2- and 3-way ball

More information

Q22 series. Ø22 mm panel mount LED indicators DISTINCTIVE FEATURES ENVIRONMENTAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS MOUNTING

Q22 series. Ø22 mm panel mount LED indicators DISTINCTIVE FEATURES ENVIRONMENTAL SPECIFICATIONS GENERAL SPECIFICATIONS MATERIALS MOUNTING IND-Q22-17-07 DISTINCTIVE FEATURES 16.75 mm colored diffused epoxy lens or 16.75 mm super bright LEDs Secret until lit polycarbonate decals or custom engraving (2.8 x 0.8) solder lug/faston terminals,

More information

Installation Devices 4

Installation Devices 4 Installation Devices 4 4.1 Tapes HelaTape Flex - Vinyl Electrical Tapes HelaTape Wrap - Vinyl Tapes HelaTape Shield - Conductive Tapes HelaTape Flex 15 - All Purpose Vinyl Insulating Tape HelaTape Flex

More information

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable According to VDE 0250 part 204 Characteristics Properties Unit Group Power cables < 1 kv Class House wiring cable Type material Cu, bare minal cross section conductor mm² Low smoke (acc. EN 61034-2) Diameter

More information

Q SERIES Ø19mm (.748") Panel Mount LED Indicators Distinctive features and specification

Q SERIES Ø19mm (.748) Panel Mount LED Indicators Distinctive features and specification Distinctive features and specification Q19_VOY1603R1US Features 19mm panel mounting LED indicator 10mm colored diffused epoxy lens or 10mm water clear super bright LEDs Plated brass bezel finished in bright

More information

SA1W: Water Detection Sensors

SA1W: Water Detection Sensors Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 ain Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.steveneng.com The SA1W is the fastest, most reliable

More information

Push Button Units and Indicator Lights

Push Button Units and Indicator Lights 3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,

More information

YS Series Contactors YS1N- F11 ****

YS Series Contactors YS1N- F11 **** YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable

More information

Thermal flow sensor TFS-35

Thermal flow sensor TFS-35 průmyslová elektronika Thermal flow sensor TFS-35 For sensing limit flow rates of fluid media and for monitoring their temperature. These sensors are intended for installation in pipes, in which the actual

More information

High Performance Thermal-Magnetic Circuit Breakers 410/520/

High Performance Thermal-Magnetic Circuit Breakers 410/520/ High Performance Thermal-Magnetic Circuit Breakers 0/0/30-... Description Single, double and three pole high performance thermal-magnetic circuit breakers with tease-free, trip-free, snap action mechanism

More information

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz Miniature Magnetic Latching Key features of the RY2L series include: Standard ice cube, 14-pin solder lug termination Operates by pulse input and maintains condition even during power failure Coils rated

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Safety Sensor CSS 180 Product Information

Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 Product Information Safety Sensor CSS 180 CSS180CSS 180 PDF-M / EN 60947-5-3 EN 954-1 Control Category 4 IEC 61508, suitable for use in SIL 3 applications BG Type-Certification in

More information

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description Capacitive sensor, Foreground Suppression Main features Compact housing Supply voltage: 10 to 30 VDC Output: 100 ma, NPN or PNP preset Make or break switching function LED indication for output and power

More information

PMS - PKS / PMW - PKW series

PMS - PKS / PMW - PKW series features / series warranty warranty Innovative housing (double enclosure) Cutting oils resistant (for machines tool) Immersion proof (sealing IP 67/68) High frequency switching Complementary output (NO+NC),

More information

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal... Safety sensor BNS Disassembly and disposal. Disassembly..... Disposal... EU Declaration of conformity Operating instructions.............pages to Original x.000 / 0.0 / v.a. - 09009- / J / 0-0-0 / AE-Nr.

More information

LD6A. LED SignaLight Towers. Clear, audible alarm sound. Warning/caution indicated by flashing light. Complies with IEC Standards (IEC60073)

LD6A. LED SignaLight Towers. Clear, audible alarm sound. Warning/caution indicated by flashing light. Complies with IEC Standards (IEC60073) LD6A LED SignaLight Towers Steady/Flashing/Alarm Warning/caution indicated by flashing light Complies with IEC Standards (IEC073) Clear, audible alarm sound 3.3 khz 70 to 90 db 2 3 4 5 LD6A LED SignaLight

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

Planning Section. Environmental conditions. Different power supply. Industrial solutions

Planning Section. Environmental conditions. Different power supply. Industrial solutions Planning Section 86 89 Environmental conditions Different power supply 90 Industrial solutions 91 Power calculation and selection of the Motorized Pulley for package transportation 93 Oil types and contents

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Non-Illuminated ushbuttons (Sub-Assembled) Contact Block + Operator + Button = Completed Unit art Numbers: Operators Style art Number Momentary Maintained LW1B-M0 LW1B-A0 LW2B-M0 LW2B-A0 Mushroom

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Locking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG

Locking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG Locking Style Spring or Solenoid Locking Two locking mechanisms are available: spring lock with energized solenoid release and energized solenoid lock with spring release. Rigid and flexible in-line actuators

More information

Magnetic switch For bypass level indicators Model BGU

Magnetic switch For bypass level indicators Model BGU Level measurement Magnetic switch For bypass level indicators BGU KSR data sheet BGU Applications Magnetic switches for detecting the limits of filling levels in bypass level indicators Chemical and petrochemical

More information

SUPER-BRIGHT MULTI-CHIP LED SIGNAL LAMPS

SUPER-BRIGHT MULTI-CHIP LED SIGNAL LAMPS SUPER-BRIGHT MULTI-CHIP LED SIGNAL LAMPS T-1-3/4 6V, 12V, 28V, 36V, 48V & 60V Multi-Chip LED Lamp Data Sheet : SEL-MCL-001-HB T-1-3/4 Midget Flanged Based T-1-3/4 Midget T-1-3/4 Bi-Pin T-1-3/4 Midget Grooved

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

General_technical_data Series

General_technical_data Series Indicator actuator 2 500 Hz: 5 g Pushbutton actuator Lens flat/level with front bezel: - Momentary max. 3 600/h - Maintain max. 1 800/h Lens flat/raised above front ring: - Momentary max. 3 600/h - Maintain

More information

EA series housings. Selection diagram. 125 General Catalogue HMI ACTUATORS ACCESSORIES COVERS. emergency button Ø 40 push-pull, windowed

EA series housings. Selection diagram. 125 General Catalogue HMI ACTUATORS ACCESSORIES COVERS. emergency button Ø 40 push-pull, windowed EA series housings Selection diagram ACTUATORS Ø 40 push-pull Ø 40 push-pull, windowed Ø 40 rotary release Ø 40 rotary release, windowed Ø 40 key release selector switch with short handle knob selector

More information

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide 1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical

More information

Thermal flow sensor TFS-35

Thermal flow sensor TFS-35 průmyslová elektronika Thermal flow sensor TFS-35 For flow monitoring rates of liquids media and for monitoring of their temperature These sensors are intended for installation in pipes, in which the actual

More information

ELECTRICAL SOLUTIONS

ELECTRICAL SOLUTIONS Ties Type FL Flexible Material: Flexible Polypropylene UL Recognized continuous use temperature: 149 F (65 C) H W UL 94 flammability rating of V-2 Factory applied adhesive tape provided for easy mounting

More information

IHS series Hall effect pushbutton switches - bushing Ø 12 mm - momentary Overview IHS SERIES Actuator shapes Electrical function Operating force Termi

IHS series Hall effect pushbutton switches - bushing Ø 12 mm - momentary Overview IHS SERIES Actuator shapes Electrical function Operating force Termi IHS series Hall effect pushbutton switches - bushing Ø 12 mm - momentary Distinctive features and specifications Momentary pushbutton (NO) 5 million cycles Low behind-panel depth Standard and high actuator

More information

1.4 SCT Temperature sensor

1.4 SCT Temperature sensor 1.4 SCT-150-14-00 Temperature sensor Pressure-proof up to 630 bar Compact construction Rugged steel housing Simple installation -50 C to +125 C 0/4...20 ma Compact construction and high pressure resistance

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

Control & Signalling Devices 22.5 mm. RoHS. Compliant

Control & Signalling Devices 22.5 mm. RoHS. Compliant Control & Signalling Devices 22.5 mm RoHS Compliant Contents Characteristics General Characteristics Products Push Buttons, Selector Switches, Latching Mushroom Head Push Buttons, Pilot Lights & Illuminated

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

S 370 MODULAR STACK LIGHTS FEATURES. Multifunctional Lamp. 1 lamp, 3 different kinds of lights. Steady, flashing and rotating.

S 370 MODULAR STACK LIGHTS FEATURES. Multifunctional Lamp. 1 lamp, 3 different kinds of lights. Steady, flashing and rotating. MODULAR STACK LIGHTS S 370 FEATURES Multifunctional Lamp An easy and functional accessory. Simplifies the un-mounting of the stack light Remount fast and flawlessly Light lamp 1 lamp, 3 different kinds

More information

Limit switches 3. Page 92. Page 92

Limit switches 3. Page 92. Page 92 Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards

More information

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR. Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with

More information

Electronic pressure switch with two switching outputs

Electronic pressure switch with two switching outputs Electronic pressure switch with two switching outputs RE 30278/04.14 Replaces: 03.06 RE 30275 1/6 Type HEDE 10 /2/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code 2

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

Data sheet... W-Series WPE 4

Data sheet... W-Series WPE 4 The PE terminals are available in two designs: standard and compact (N), with rated cross-section from 1.5 mm² to 150 mm² (e.g. 2.5 mm² WPE 2.5 or 4 mm² WPE 4N). General ordering data Order No. 1010100000

More information

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M Compact Vacuum Regulator Series ITV RoHS For single unit and single unit for manifold ITV Pressure range kpa Power supply voltage 4 VDC ±% to VDC How to Order N Cable connector N Without cable connector

More information

Sx-F/G-SG-ST SERIES APPLICATIONS

Sx-F/G-SG-ST SERIES APPLICATIONS Safety Photocells Sx-F/G-SG-ST SERIES The emitter-receiver photocells of the Sx-F/G-SG-ST series have been homologated to function with the control units of the SG-BWS series that together form a safety

More information

TeSys GV2 - GV3 Manual Starters and Protectors

TeSys GV2 - GV3 Manual Starters and Protectors TeSys GV GV Manual Starters and Protectors A stronger, longterm connection Courtesy of Steven Engineering, Inc. 0 Ryan Way, South San Francisco, CA 94080670 General Inquiries: (800) 67048 www.stevenengineering.com

More information

Pilot devices, 22 mm. Catalogue. 1SFC151001C0201, Edition 2, January 2006 Superseedes Catalogue 1SFC15100C0201 of December SFC151169F0001

Pilot devices, 22 mm. Catalogue. 1SFC151001C0201, Edition 2, January 2006 Superseedes Catalogue 1SFC15100C0201 of December SFC151169F0001 Catalogue Pilot devices, 22 mm 1SFC151001C0201, Edition 2, January 2006 Superseedes Catalogue 1SFC15100C0201 of December 2004 1SFC151169F0001 ABB A sure hit in Pilot Devices Part of comprehensive ABB program

More information

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4 Compact Electro-Pneumatic Regulator Series ITV RoHS How to Order [Option] For single unit and single unit for manifold ITV N Pressure range. MPa. MPa.9 MPa Power supply voltage 4 VDC ±% to VDC Cable connector

More information

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces: Electronic pressure switch Type HEDE 10 RE 30277 Edition: 2017-02 Replaces: 2016-06 Component series 3X Maximum operating pressure 600 bar Features Suitable for measuring pressures in hydraulic systems

More information

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Main Range of product Product or component type Pressure sensor type Device short name Pressure sensor size Controlled

More information

3 CE-Conformity. General information. Signal lamps. 3-2 Signal lamps

3 CE-Conformity. General information. Signal lamps. 3-2 Signal lamps Signal lamps General information Signal Lamps with integral lamps/s The soldered lamps/s without base cannot be replaced. Signal Lamps with lamp socket An integral lamp socket allows replacement of lamps/s

More information

Main catalogue. ESSAILEC Test Blocks

Main catalogue. ESSAILEC Test Blocks Main catalogue ESSAILEC Test Blocks Test Blocks ESSAILEC has been especially designed to fit the electricity Utilities requirements for safe and reliable testing. ESSAILEC allows the testing, without any

More information

e.

e. e. e. e. e. e. e. e. e. e. e. Characteristics Control and signalling units Ø 220 Harmony XB7 Monolithic pushbuttons, switches and pilot lights 1 2 Environment Protective treatment Standard version TH Ambient

More information

Busbar Systems Accessories

Busbar Systems Accessories Busbar Systems Accessories SU1 SU Busbar Material: Thermoplastic Polyester Rated voltage up to 1000V, 50-60Hz Inserts can be used to facilitate the use of smaller busbar SU Busbar holders - Rated up to

More information

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return

Power consumption In operation At rest For wire sizing. Cable 1 m, 2 x 0.75 mm 2 Cable 1 m, 6 x 0.75 mm 2 Functional data Torque Motor Spring return echnical data sheet FA-S2 actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 2 m 2 orque 10 m ominal voltage

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve Product data sheet 5.1 51.364 AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve How energy efficiency is improved Automatic adaptation to ball valve, precise activation

More information

Indicator body round for raised full face, black plastic, 22.5 mm mounting. Part No For complete switch also order

Indicator body round for raised full face, black plastic, 22.5 mm mounting. Part No For complete switch also order Series 14.5 mm 0.5 mm IP67 5 50 V INDITOR pushbutton keylock selector buzzer hoose one component from each of the coloured sections to assemble a complete switch. Product Profile Indicator The Series 14

More information

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features sales@jumo.co.uk info.us@jumo.net Page 1/10 JUMO dtrns p5 Pressure Sensor with IO-Link pplication Process automation Machines for the food and beverage industry General mechanical and apparatus engineering

More information

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22) Ex-Floodlight PXLED (Ex-Zone 1, 2, 21 and 22) Lighting under harsh conditions The new modular LED floodlight series PXLED is suited for nearly every kind of lighting task in hazardous areas, including

More information

FOOT SWITCHES

FOOT SWITCHES - 83 - FOOT SWITCHES PS... / PD... Foot Switches Double insulation - Plastic Casing IP65 Description Applications Foot switch operated machines such as: shearing machines, spinning machines, spinning lathers,

More information

Bulletin 871P Can Sensors

Bulletin 871P Can Sensors Bulletin 871P Can Sensors Description Bulletin 871P inductive proximity can sensors are self-contained solid state devices, designed specifically for sensing size 202 to 704 metal cans without physical

More information

TURCK Inductive Sensors - Rectangular

TURCK Inductive Sensors - Rectangular Courtesy of Steven Engineering, Inc. 30 Ryan Way, South San Francisco, C, 94080-6370 Main Office: (650) 588-900 Outside Local rea: (800) 58-900 www.stevenengineering.com TURCK Inductive Sensors - Rectangular

More information